Loading...
Staff Report and Attachment 1 PREPARED BY: JOEL PAULSON Community Development Director _______________________________________________________________________________________ Reviewed by: Assistant Town Manager Town Attorney Finance _________________________________________________________________________ S:\COUNCIL REPORTS\2016\11-01-16\09 50 University Ave - Wine Cellar\09 Staff Report FINAL.docx 10/27/2016 9:49 AM JGP MEETING DATE: 11/01/16 ITEM NO: 9 COUNCIL AGENDA REPORT DATE: OCTOBER 26, 2016 TO: MAYOR AND TOWN COUNCIL FROM: LAUREL PREVETTI, TOWN MANAGER SUBJECT: CONDITIONAL USE PERMIT APPLICATION U-16-004. PROJECT LOCATION: 50 UNIVERSITY AVENUE, SUITE 180. PROPERTY OWNER: SRI OLD TOWN LLC. APPLICANT: STEVE HAUCK, WINE CELLAR. CONSIDER A REQUEST TO MODIFY AN EXISTING CONDITIONAL USE PERMIT FOR A RESTAURANT (WINE CELLAR) TO ALLOW FOR AN INCREASE OF 60 ADDITIONAL SEATS, TO MODIFY THE DISTRIBUTION OF EXISTING SEATING, AND TO ALLOW INDOOR ENTERTAINMENT BEFORE 10:00 P.M. ON PROPERTY ZONED C-2:LHP:PD. APN 529-02-044. RECOMMENDATION: After opening and closing the public hearing, it is recommended that the Town Council accept the Planning Commission’s recommendation to approve the Conditional Use Permit (CUP) application with modified conditions for a restaurant (Wine Cellar) to allow for an increase of 60 additional seats, modify the distribution of existing seating, and allow indoor entertainment before 10:00 p.m. for a property located at 50 University Avenue, Suite 180. BACKGROUND: The applicant is requesting approval to modify their existing CUP to allow:  An increase in the number of permitted seats from 140 to 200 for two new private dining rooms;  A redistribution of allowed seating in the existing bar, dining, and outdoor areas; and  Indoor entertainment prior to 10:00 p.m. pursuant to the Policy for Late Night Entertainment (Attachment 1, Exhibit 10). PAGE 2 MAYOR AND TOWN COUNCIL SUBJECT: 50 UNIVERSITY AVENUE, SUITE 180/U-16-004 OCTOBER 26, 2016 BACKGROUND (Continued): The application was considered by the Planning Commission on September 28, 2016. The Commission forwarded a recommendation of approval to the Town Council as discussed in more detail in this report. The Council is the final deciding body for the Conditional Use Permit application due to the existing restaurant’s full alcohol service. DISCUSSION: A. Project Summary The project is requesting approval for a conversion of 2,661 square feet to accommodate an expansion of the existing 3,186-square foot restaurant. The uses of the areas proposed for the expansion are: 881 square feet of office, electrical/maintenance, and storage area; and 1,780 square feet of vacant space that was formerly occupied by a retail tenant (Borders) for storage. The renovation of the existing office, storage, and mechanical areas would allow for the existing restaurant and two proposed private dining rooms to be connected by a new corridor. A new office and two additional restrooms are also proposed as part of the expansion (see Attachment 1, Exhibit 11, Plan Sheet A2.1). The existing CUP permits a maximum of 140 seats. The applicant is requesting approval for an additional 60 seats for a total of 200 seats. The 60 additional seats would be distributed between two new dining areas for private events. There are 16 seats proposed for Dining Area Two and 44 seats proposed for Dining Area Three (Attachment 1, Exhibit 11). The applicant is also proposing to modify the approved distribution of seating allowed in the bar, dining, and outdoor areas. Condition 2 of the existing conditions of approval states that a maximum of 140 seats are allowed – 79 dining seats, 15 inside bar seats, and 46 outdoor dining seats (Attachment 1, Exhibit 4). The applicant is requesting to reduce the number of seats in the dining area from 79 to 72, reduce the number of seats in the bar area from 15 to 10, and increase the number of seats in the outdoor area from 46 to 58. The applicant stated in their letter of justification that there is a demand for outdoor seating and by reallocating the seats the restaurant will be able to provide more outdoor seating options (Attachment 1, Exhibit 8). Alcoholic Beverage Policy (ABP) The applicant currently has approval for full alcohol service for the existing restaurant and is proposing the same service for the two new private dining areas. The entire restaurant, with the exception of the bar area, would be required to provide full meal service with all alcohol sales. PAGE 3 MAYOR AND TOWN COUNCIL SUBJECT: 50 UNIVERSITY AVENUE, SUITE 180/U-16-004 OCTOBER 26, 2016 DISCUSSION (Continued): The deciding body must review the application and determine if the proposal continues to provide a benefit to the community to continue to operate past 10:00 p.m. as required by the Alcoholic Beverage Policy (Attachment 1, Exhibit 5). The request is consistent with the Town Code and the existing Alcoholic Beverage Policy (Attachment 1, Exhibit 5). The private dining rooms would have the same hours as the existing restaurant: 11:00 a.m. to 2:00 a.m. Monday through Friday and 9:30 a.m. to 2:00 a.m. Saturday and Sunday. Parking and Traffic The existing and the proposed use require one parking space for every three seats. The larger property (Old Town) has credit for 464 spaces in the Parking Assessment District and provides 199 spaces on-site for a total of 663 parking spaces. 47 parking spaces are currently allocated to the existing use in compliance with the required parking for the existing CUP. The property owner has agreed to allocate an additional 20 parking space credits to the tenant (Wine Cellar) to accommodate the proposed addition of 60 seats (Attachment 1, Exhibit 9). Of the 2,661 square feet of space proposed for the expansion, 881 square feet is currently being used as office, electrical/maintenance and storage area (shopping center use), and the remaining 1,780 square feet was formerly occupied by a retail tenant for storage (retail use). The application’s increase of 60 seats of quality restaurant does not increase traffic beyond the previous retail use and shopping center use and would not require payment of traffic impact fees. Entertainment The applicant is requesting a modification to the existing CUP by replacing a condition that limits entertainment to acoustical music inside of the restaurant three days a week and prohibits amplified music inside or outside the restaurant (Attachment 1, Exhibit 4). The new condition would allow indoor entertainment before 10:00 p.m. in conformance with the Town Policy Regulating Late Night Entertainment. B. Planning Commission On September 28, 2016, the Planning Commission conducted a public hearing for the subject application (Attachment 3 contains the verbatim minutes of the meeting) and recommended approval of the CUP application subject to draft conditions with the following modification:  Indoor entertainment before 10:00 p.m. in conformance with the Town Policy Regulating Late Night Entertainment is allowed. PAGE 4 MAYOR AND TOWN COUNCIL SUBJECT: 50 UNIVERSITY AVENUE, SUITE 180/U-16-004 OCTOBER 26, 2016 DISCUSSION (Continued): At the Planning Commission meeting the applicant was agreeable to the modification to limit entertainment pursuant to the Late Night Entertainment Policy to indoor entertainment only. An updated set of conditions that includes the Planning Commission’s recommendation to allow indoor entertainment is contained with the proposed resolution to approve the subject application (Attachment 5, Exhibit A). The Planning Commission also raised a question regarding Ordinance 2021 and its applicability to the subject application. Ordinance 2021 discourages the displacement of retail uses by restaurant uses by requiring the Planning Commission to conduct a careful review of all applications for new restaurant uses in the C-2 zone (Attachment 4). Staff does not believe Ordinance 2021 is applicable to this space. Of the 2,661 square feet of space proposed for the conversion, 1,780 square feet was formerly occupied by a retail use (Borders) and was used for storage. The space would not be appropriate for a retail use because of its location in the basement level, and lack of retail street presence. Additionally, the space has never been used as a retail sales area. ENVIRONMENTAL ASSESSMENT: The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of California Environmental Quality Act, Section 15301: Existing Facilities. PUBLIC COMMENT: At this time, the Town has not received any public comment. COORDINATION: The evaluation of the application was coordinated with the Building Division, Economic Vitality, Parks and Public Works Department, and Police Department. CONCLUSION: The Planning Commission recommended approval of the application subject to a modified condition of approval discussed above and included in Exhibit A of Attachment 5. It is recommended that the Town Council adopt a Resolution (Attachment 5) approving Conditional Use Permit U-16-004 to allow for an increase of 60 additional seats, modify the distribution of existing seating, and allow indoor entertainment before 10:00 p.m. with the conditions provided in Exhibit A of Attachment 5. PAGE 5 MAYOR AND TOWN COUNCIL SUBJECT: 50 UNIVERSITY AVENUE, SUITE 180/U-16-004 OCTOBER 26, 2016 ALTERNATIVES: Alternatively, the Council may: 1. Adopt a Resolution to approve the application subject to modified or additional conditions of approval (Exhibit A to Attachment 5); or 2. Remand the application to the Planning Commission with specific direction (Attachment 6); or 3. Adopt a Resolution to deny the Conditional Use Permit application (Attachment 7). Attachments: 1. September 28, 2016 Planning Commission Staff Report (with Exhibits 1-11) 2. September 28, 2016 Planning Commission Desk Item (with Exhibits 12 and 13) 3. September 28, 2016 Planning Commission Verbatim Minutes (45 pages) 4. Ordinance 2021 (two pages) 5. Draft Resolution to Approve the project (includes Exhibit A – Conditions of Approval) 6. Draft Resolution to Remand the project to the Planning Commission 7. Draft Resolution to Deny the project Distribution cc: Steve Hauck, 50 University Avenue, Suite 180, Los Gatos CA 95030 Mark English Architects, 523 Francisco Street, San Francisco, CA 94133 Felice Arredondo, Federal Realty, 356 Santana Row, San Jose, CA 95128 TOWN OF LOS GATOS ITEM NO: 5 PLANNING COMMISSION STAFF REPORT Meeting Date: September 28, 2016 PREPARED BY: APPLICATION NO: LOCATION: APPLICANT: PROPERTY OWNER: CONTACT PERSON: APPLICATION SUMMARY: Jocelyn Puga, Ass ociate Planner jpuga@ lo s ga to s ca.gov Conditional Use Permit U-16-004 50 University Avenue, Suite 180 (east side of University Avenue, approximately 500 feet north of W. Main Street) Mark English Architects Sri Old Town LLC Steve Hauck, Wine Cellar Requesting approval to modify an existing Conditional Use Permit for a restaurant (Wine Cellar) to allow for an increase of 60 additional s eats, to modify the distribution of existing seating, and to allow entertainment before 10:00 p.m. on property z oned C-2 :LHP:PD. APN 529-02-044. DEEMED COMPLETE: August 9, 2016 FINAL DATE TO TAKE ACTION: February 9, 2017 RECOMMENDATION: Forward a recommendation of approval to the Town Council PROJECT DAT A: General Plan Designation: Zoning Designation: Applicable Plans & Standards: Central Business Di s trict C-2:LHP:PD, Central Bu siness District, Landmark Historic Preservation, Planned Development None Parcel Size: 4.17 acres Surrounding Area : i Existing Land General Plan I Use - North , Residential Medium Densiry Residential East-_,L os Gatos Creek N/ A ................. ) ~tlighw~yJ .? .... __ ..J ·-..... --·· .. -· .. . .......... . South i Commercial j Central Business District West l Co~ercial ___ -Cent~ai .. Busine ~-;District Zoning R-l:D:LHP NI A . C -2:LHP C-2:LHP ATTACHMENT 1 Planning Commission Staff Report -Page 2 50 University Avenue, Suite 180/U-16-004 September 28, 2016 CEQA: FfNDINGS: As required, pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, this project is Categorically Exempt, Section 1530 I: Existing Facilities. • As required, pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, this project is Categorically Exempt, Section 1530 I: Existing Facilities. • As required by Section 29.20.190 of the Town Code for granting a Conditional Use Permit. • That the project is in conformance with Planned Development Ordinance 2025. • That the project is consistent with the Redevelopment Plan for the Central Los Gatos Redevelopment Project area. ACTION: Recommendation to the Town Council EXHIBITS: I . Location Map BACKGROUND: 2. Required Findings (one page) 3 . Proposed Conditions of Approval (four pages) 4 . Resolution 2005-092 and the Existing Conditions of Approval (five pages) 5. Town Alcoholic Beverage Policy, including Exhibit A (six pages) 6. Planned Development Ordinance 2025 (20 pages) 7. Project Description (one page), received August 9, 2016 8. Letter of Justification (two pages), received August 9, 2016 9. Letter from the landlord approving the allocation of parking (one page), received June 7, 2016 10. Policy Number 1-03 Regulating Late Night Entertainment, dated June 22, 2016 and Council Agenda Report, dated June 13, 2016 (seven pages) 11. Development plans (five sheets) received August 9, 2016 The subject site is located on the east side of University Avenue. In 1977, the Town Council adopted an ordinance that required all restaurants to obtain a Conditional Use Permit (CUP). All pre-existing restaurants were categorized as nonconforming and given a 20-year amortization period to obtain a CUP. On February I 0, 1999 the Town Council approved a CUP to legalize the existing restaurant with outdoor seating and full alcohol service. On October 21, 2002 the Town Council approved a request to modify the CUP to extend the hours of operation to 2:00 a.m. seven days a week and to amend the hours on Saturday and Sunday to allow for an opening time of9:30 a.m . On August 15, 2005 the Town Council approved a request to modify the CUP to allow for an increase in the number of seats from 100 to 140 but denied a request for increased Planning Commission Staff Report -Page 3 50 University A venue, Suite 180/U-16-004 September 28, 2016 entertainment. The existing CUP permitted unamplified acoustic music Thursday through Saturday. The applicant proposed amplified music and dancing seven days a week. The Council 's decision to deny the request for increased entertainment was based in part on the Alcohol Beverage Policy that requires the adoption of standards and a permit process, which had not occurred, and the applicant's inability to compromise (Exhibit 4). Late Night Entertainment Policy At a series of Study Sessions in late 2015, the Council received public testimony regarding alcohol beverage service and entertainment. The Council directed staff to explore and bring back a variety of economic vitality and business related topics including a framework for an ordinance or operational permit for alcohol and entertainment. The Policy Committee reviewed the work completed over the last several years for alcohol and entertainment, noting that the complexity that continues to arise during these discussions is due to the difference between issues associated with alcoholic beverage consumption versus those regarding entertainment. As a result , the Policy Committee recommended that the two topics be separated and that the Council consider only a policy on entertainment. In June of 2016, the Town Council adopted, at the recommendation of the Policy Committee, a Late Night Entertainment Policy allowing entertainment complying with the currently adopted noise ordinance by right before 10:00 p .m ., and allowance for late night entertainment after 10 :00 p.m. with the approval of a separate Late Night Entertainment permit. This action is consistent with the Town Council 's adopted Strategic Priority to strengthen the Town 's economic vitality and provide businesses with greater opportunity for customer attraction and retention. Those establishments with existing CUPs that do not have conditions specifically allowing entertainment fall into three categories: those with a CUP that is silent on entertainment; those with a CUP that states they must comply with the Town's provisions on entertainment; and those with a CUP that does not allow entertainment and/or amplified sound. For the first two categories of CUPs, the businesses are able to observe the new regulations with the adoption of the proposed policy. Businesses that are not allowed to have live entertainment and/or amplified sound, such as the subject restaurant, are required to submit applications for modification to their existing CUPs. PROJECT DESCRIPTION: A. Conditional Use Permit The applicant is requesting approval to modify their existing CUP to allow: • An increase in the number of permitted seats from 140 to 200; Planning Commission Staff Report -Page 4 50 University Avenue, Suite 180/U -16-004 September 28, 2016 • Modification of the distribution of their allowed seating in the existing bar, dining, and outdoor area; and • Removal of the condition which restricts entertainment pursuant to the Policy for Late Night Entertainment (Exhibit 11 ). When reviewing a CUP , the deciding body should consider the information in the applicant's business plan; however, the key consideration should be the explicit proposed use since the business plan can change from owner to owner. The explicit use may be, and is often, defined in the recommended conditions of approval as a "use" condition . The CUP runs with the land , and the deciding body should review applications based on the explicit use as opposed to the applicant or the applicant's business plan. B. Location and Surrounding Neighborhood The subject site is located east side of University Avenue, approximately 500 feet north of W . Main Street. The property abuts commercial properties to the south and west, residential to the north, and the Los Gatos Creek and Highway 17 to the east. C. Zoning Compliance The zoning for the property is C-2:LHP:PD (Central Business District, Landmark Historic Preservation, Planned Development). The C-2 :LHP:PD zone permits a restaurant subject to the approval of a CUP . ANALYSIS: A. Project Summary The applicant is requesting approval for a conversion of2,661 square feet to accommodate an expansion of the existing 3,186-square foot restaurant. The uses of the areas proposed for the expansion are: 881 square feet of office, electrical/maintenance and storage area; and l, 780 square feet of vacant space that was formerly occupied by a retail tenant (Borders). The renovation of the existing office, storage, and mechanical areas would allow for the existing restaurant and proposed private dining rooms to connect through a new corridor. A new office and two additional restrooms are proposed as part of the expansion (Sheet A2.l , Exhibit 11). The existing CUP permits a maximum of 140 seats. The applicant is requesting approval for an additional 60 seats resulting in a total of 200 seats. The 60 seats would be distributed between two new dining areas for private events. There are 16 seats proposed for Dining Area Two and 44 seats proposed for Dining Area Three (Sheet A2 .1, Exhibit 11 ). Planning Commission Staff Report -Page 5 50 University Avenue, Suite 180/U-16-004 September 28, 2016 The applicant is also proposing to modify the approved distribution of seating allowed in the bar, dining, and outdoor areas. Condition 2 of the existing conditions of approval states that a maximum of 140 seats are allowed -79 dining seats, 15 inside bar seats, and 46 outdoor dining seats (Exhibit 4). The applicant is requesting to reduce the number of seats in the dining area from 79 to 72, reduce the number of seats in the bar area from 15 to 10, and increase the number of seats in the outdoor area from 46 to 58. The applicant stated in their letter of justification that there is a demand for outdoor seating and by reallocating the seats the restaurant will be able to provide more options to residents and visitors looking for quality restaurants with outdoor dining (Exhibit 8). B. Alcoholic Beverage Policy (ABP) The Town Code requires any new or changes to existing service of alcoholic beverages to be considered with a CUP. The deciding body is the Town Council with a recommendation by the Planning Commission. The two new private dining areas, just like the entire restaurant, would be required to provide full meal service with all alcohol sales. The request is consistent with the Town Code and the existing Alcoholic Beverage Policy (Exhibit 5). The private dining rooms would utilize the same hours of the existing restaurant: 11:00 a.m. to 2 :00 a.m. Monday through Friday and 9:30 a.m. to 2:00 a.m. Saturday and Sunday. The Police Department has reviewed the application, and has no comments or concerns. C. Parking The existing and the proposed use require one parking space for every three seats. The larger property (Old Town) has credit for 464 spaces in the Parking Assessment District and provides 199 spaces onsite for a total of 663 parking spaces. 4 7 parking spaces are allocated to the existing use in compliance with the required parking. The landlord for the property has agreed to allocate an additional 20 parking space credits to the tenant (Wine Cellar) to accommodate the proposed addition of 60 seats (Exhibit 9). D. Traffic The applicant is proposing a 2,661-square foot expansion to an existing 3 ,186-square foot restaurant. Of the 2,661 square feet of space proposed for the addition, 881 square feet is currently being used as office, electrical/maintenance and storage area (shopping center use), and the remaining 1, 780 square feet was formerly occupied by a retail tenant (retail use). The application's increase of 60 seats of quality restaurant does not increase traffic beyond the previous retail use and shopping center use and would not require payment of traffic impact fees. Planning Commission Staff Report -Page 6 50 University A venue, Suite 180/U-16-004 September 28 , 2016 E. Late Night Entertainment The applicant is requesting a modification to the existing CUP in the form of removal of a condition limiting entertainment to acoustical music inside of the restaurant three days a week and prohibiting amplified music inside or outside the restaurant (Exhibit 4). The following represents the proposed modifications: Existing Condition of Approval Acoustical musical entertainment is permitted inside only and shall be limited to Thursday, Friday, and Saturday only. There shall be no amplified music inside or outside the restaurant. Proposed Condition of Approval Entertainment before 10:00 p .m . in conformance with the Town Policy Regulating Late Night Entertainment is allowed. F. General Plan The goals and policies of the 2020 General Plan applicable to this project includes but is not limited to: • Policy LU-9.2 -Maintain a variety of commercial uses, including a strong Downtown commercial area combined with Los Gatos Boulevard and strong neighborhood commercial centers to meet the shopping needs ofresidents and to preserve the small- town atmosphere. • Goal LU-10 -To preserve Downtown Los Gatos as the historic center of the Town with goods and services for local residents while maintaining the existing Town identity, environment and commercial vitality. • Policy CD-10.2 -Encourage outdoor seating for restaurants/coffee shops when the historic character and quality of the Downtown and adjacent neighborhoods can be maintained. G. Environmental Review The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15301: Existing Facilities. H. Redevelopment Plan for the Central Los Gatos Redevelopment Project Area The Redevelopment Plan contains a Redevelopment Land Use Map that designates proposed land uses to be permitted in the Central Los Gatos Redevelopment Project Area. The subject property is designated commercial and, per the Redevelopment Plan, shall be Planning Commission Staff Report -Page 7 50 University Avenue, Suite 180/U-16-004 September 28 , 2016 used for the general commercial uses set forth and described in the Town 's General Plan. The proposed use falls under general commercial uses. I. Conditional Use Permit Findings In order to grant approval of a Conditional Use Permit, the hearing body must make the following findings: (1) The proposed use of the property is essential or desirable to the public convenience or welfare; and (2) The proposed use will not impair the integrity and character of the zone; and (3) The proposed use would not be detrimental to public health, safety or general welfare; and (4) The proposed use of the property is in harmony with the various elements or objectives of the General Plan and the purposes of the Town Code. The proposed use is desirable to the public convenience and welfare in that it will provide high quality indoor and outdoor dining options for residents and visitors. The proposed use will not impair the integrity and character of the zone in that the proposed use maintains an existing restaurant use with full bar service in a commercial zone. The proposed use will not impact public health, safety or general welfare as the conditions regarding operating hours and seating would mitigate potential impacts. The use complies with the objectives of the General Plan and Town Code as discussed within this report. PUBLIC COMMENTS: At this time, the Town has not received any public comment. CONCLUSION AND RECOMMENDATION: A. Conclusion The applicant is proposing a 2,661-square foot expansion to allow for two private dining areas with 60 new seats, a modification to the distribution of the existing seating to allow for more outdoor seating, and removal of the condition which prohibits entertainment pursuant to the Policy for Late Night Entertainment. The proposed use complies with the required parking and will not have impacts to traffic. The applicant's proposal complies with the Town 's Alcoholic Beverage Policy. B. Recommendation Based on the above information, staff recommends the Planning Commission forward a recommendation of approval to the Town Council. If the Planning Commission finds merit with the proposal , it should: This Page Intentionally Left Blank PLANNING COMMISSION -September 28, 2016 REQUIRED FINDINGS FOR: 50 University A venue, Suite 180 Conditional Use Permit Application U-16-004 Requesting approval to modify an existing Conditional Use Permit for a restaurant (Wine Cellar) to allow for an increase of 60 additional seats, to modify the distribution of existing seating, and to allow entertainment before 10:00 p.m. on property zoned C-2:LHP:PD. APN 529-02-044. PROPERTY OWNER: Sri Old Town LLC APPLICANT: Mark English Architects CONTACT PERSON: Steve Hauck, Wine Cellar FINDINGS Required fmding for CEQA: • The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15301: Existing Facilities. Required fmdings for a Conditional Use Permit: • As required by Section 29.20 .190 of the Town Code for granting a Conditional Use Permit: (1) The proposed use is desirable to the public convenience and welfare in that it will provide high quality indoor and outdoor dining options for residents and visitors; and (2) The proposed use will not impair the integrity of the zone, in that the proposed use maintains an existing restaurant use with full bar service in a commercial zone; and (3) The proposed use will not be detrimental to public health, safety or general welfare, as the conditions regarding operating hours and seating on the permit will mitigate potential impacts; and (4) The proposed use is in harmony with the General Plan and Town Code. Required Compliance with Planned Development Ordinance 2234: • The Conditional Use Permit is in conformance with Planned Development Ordinance 2025 . Required fmding for the Redevelopment Plan for the Central Los Gatos Redevelopment Project Area: • That the proposed project is consistent with the Redevelopment Plan for the Central Los Gatos Redevelopment Project Area (Section IV.B) in that the subject property is designated commercial and the proposed use falls under general commercial uses. N:\DEV\FINDINGS \20 I 6\5 0University _ Suite l 80.doc x EXHIBIT 2 This Page Intentionally Left Blank PLANNING COMMISSION-September 28, 2016 CONDITIONS OF APPROVAL 50 University Avenue, Suite 180 Minor Architecture and Site Application S-16-0 17 Requesting approval to modify an existing Conditional Use Permit for a restaurant (Wine Cellar) to allow for an increase of 60 additional seats, to modify the distribution of existing seating, and to allow entertainment before 10:00 p.m. on property zoned C -2:LH P:PD. APN 529-02-044. PROPERTY OWNER: Sri Old Town LLC APPLICANT: Mark English Architects CONT ACT PERSON: Steve Hauck, Wine Cellar TO THE SATISFACTION OF THE COMMUNITY DEVELOPMENT DIRECTOR : Planning Division 1. APPROVAL: This application shall be completed in accordance with all of the conditions of approval and in substantial compliance with the approved plans. Any changes or modifications to the approved plans and/or business operation shall be approved by the Community Development Director, Development Review Committee or the Planning Commission depending on the scope of the changes. 2 . EXPIRATION : The approval will expire two years from the approval date pursuant to Section 29.20.320 of the Town Code, unless the approval has been vested. 3. RESTAURANT USE: A quality restaurant and full service bar is permitted. 4. HOURS: The hours of operation for the restaurant shall be 11:00 a.m . to 2:00 am . Monday through Friday and 9 :30 a.m . to 2:00 a.m . Saturday and Sunday. 5. SEATS : The maximum allowed seating is -14-0 200 (.'.79 72 inside dining seats , +s lQ bar seats, 4e 58 outside dining seats, and 60 private dining seats). 6. ALCOHOL SERVICE: No alcoholic beverages outside of the bar area shall be served without meal service. A meal is defined as a combination of food items selected from a menu (breakfast, brunch, lunch, or dinner). Appetizers such as popcorn, nachos, pretzels, potato skins, relish trays, etc. (hot or cold) are not meals. 7. ENTERTAINMENT: Acoustic musical entertainment is permitted inside only and shall be limited to Thursday, Friday, and Saturday only. There shall be no amplified music inside or outside the restaurant. 7. ENTERTAINMENT. Entertainment before 10 :00 p.m. in conformance with the Town Policy Regulating Late Night Entertainment is allowed. 8. RECYCLED CONTAINERS : Any take-out food shall be served in containers made of recycled materials . 9. REUSABLE CONTAINERS: Pursuant to Town Code all on-site meals shall be served with re-usable dishware and utensils. 10. LAPSE FOR DISCONTINUANCE: If the activity for which the Conditional Use Permit has been granted is discontinued for a period of one (1) year, the approval lapses pursuant to Section 29.20.340 of the Zoning Ordinance. 11 . TOWN INDEMNITY : Applicants are notified that Town Code Section 1.10 .115 requires that any applicant who receives a permit or entitlement from the Town shall defend , indemnify, and hold harmless the Town and its officials in any action brought b y a third .EXtumr 3 party to overturn, set aside, or void the permit or entitlement. This requirement is a condition of approval of all such permits and entitlements whether or not expressly set forth in the approval , and may be secured to the satisfaction of the Town Attorney. 12. COMPLIANCE MEMORANDUM : A memorandum shall be prepared and submitted with the building plans detailing how the Conditions of Approval will be addressed. TO THE SATISFACTION OF THE CHIEF OF POLICE: 13. GENERAL: The restaurant is subject to the following: a. Uniformed privately provided security guards may be required in or around the premises by the Chief of Police if alcohol related problems recur that are not resolved by the licensed owner. b. At the discretion of the Chief of Police, periodic meetings will be conducted with representatives from the Police Department for on-going employee training on alcoholic beverage service to the general public. c. All establishments shall use an employee training manual that addresses alcoholic beverage service consistent with the standards of the California Restaurant Association. d. All licensed operators shall have and shall actively promote a designated driver program such as complimentary non-alcoholic beverages for designated drivers. e. Taxicab telephone numbers shall be posted in a visible location. Building Division 14. PERMITS REQUIRED: A Building Permit shall be required for any and all alterations to the existing commercial building. Separate permits are required for electrical, mechanical, and plumbing work as necessary. 15. CONDITIONS OF APPROVAL: The Conditions of Approval must be blue-lined in full on the cover sheet of the construction plans . A Compliance Memorandum shall be prepared and submitted with the building permit application detailing how the Conditions of Approval will be addressed. 16. SIZE OF PLANS : Four sets of construction plans, minimum size 24" x 36", maximum size 30" x 42". 17. DEMOLITION REQUIREMENTS: Be sure that all utilities have been disconnected or "Safe Back" to disconnect. No demolition work shall be done without first obtaining a Permit from the Town. 18. TITLE 24 ENERGY COMPLIANCE: All required California Title 24 Energy Compliance forms must be blue-lined on the plans including lighting compliance resulting from lighting changes and for the mandatory measures . 19. TITLE 24 ACCESSIBILITY -COMMERICAL: For any proposed tenant improvements, on-site parking and general path of travel shall comply with the latest California Title 24 Accessibility Standards. Work shall include , but not be limited to, accessibility to building entrances from parking facilities and sidewalks. Necessary work shall first be investigated by the design Architect and then confirmed by Building Division Staff. 20. PLANS: The plans for this commercial building project shall be prepared under the direct supervision of a licensed Architect or Engineer. (Business and Professionals Code Section 5537) 21 . APPROVALS REQUIRED: The project requires the following departments and agencies approval before issuing a building permit: a. Community Development -Planning Division: Jocelyn Puga at (408) 354-6875 b. Santa Clara County Fire Department: (408) 378-4010 22. ADVISORY COMMENTS for EXTERIOR MODIFICATIONS & TENANT IMPROVEMENTS: a. In addition to all new work complying with the Code for accessibility, when existing Buildings are altered or remodeled they must be made accessible to persons with physical disabilities in accordance with the CBC Section 1 lB-202, "Accessibility for E xisting Buildings". Existing accessibility features and/or elements required to be accessible in order of priority include: (a) Accessible main entrances with required signage and door hardware and 24" strike side clearance; (b) Accessible route to altered area (including parking space and path of travel from public way and necessary signage ); and ( c) Accessible Restrooms. b. If Tenant hnprovements are made and the cost of these alterations or remodeling is less than a threshold amount (currently at $150,244.00) and the cost to provide all those features listed above is disproportionate to the improvement costs (i.e. more than 20% of the budget), then the Owner is only required to provide disabled access upgrades to 20% of the project budget or the plans shall show full accessibility compliance. Please obtain the Town 20% Rule Form from the Town Permit Counter or download from the Town of Los Gatos website at www.losgatosca.gov and completely fill it out showing all the required upgrades that will be provided and their costs. This form must be permanently affixed (i .e. blue-lined, sticky-backed) onto the plans. c. Exiting and Occupant Load shall be in strict compliance with California Building Code Chapter 10. A minimum of two exits, adequately separated, are required from the new dining area. d. Maintain a minimum aisle width of 36 inches. TO THE SATISFACTION OF THE DIRECTOR OF PARKS AND PUBLIC WORKS : Engineering Division 23. GENERAL: All public improvements shall be made according to the latest adopted Town Standard Plans, Standard Specifications and Engineering Design Standards. All work shall conform to the applicable Town ordinances. The adjacent public right-of-way shall be kept clear of all job-related mud, silt, concrete, dirt and other construction debris at the end of the day. Dirt and debris shall not be washed into storm drainage facilities. The storing of goods and materials on the sidewalk and/or the street will not be allowed unless an encroachment permit is issued . The Applicant's representative in charge shall be at the job site during all working hours. Failure to maintain the public right-of-way according to this condition may result in the issuance of correction notices, citations, or stop work orders and the Town performing the required maintenance at the Applicant's expense. 24. CHANGE OF OCCUPANCY : Prior to initial occupancy and any subsequent change in use or occupancy of any non-residential condominium space, the buyer or the new or existing occupant shall apply to the Community Development Department and obtain approval for use determination and building permit and obtain inspection approval for any necessary work to establish the use and/or occupancy consistent with that intended. 25 . PARKING: Any proposed parking restriction must be approved by The Town of Los Gatos, Community Development Department. 26. CONSTRUCTION STREET PARKING: No vehicle having a manufacture's rated gross vehicle weight exceeding ten thousand (10,000) pounds shall be allowed to park on the portion of a street which abuts property in a residential zone without prior to approval from the Town Engineer. 2 7. CONSTRUCTION HOURS : All subdivision improvements and site improvements construction activities , including the delivery of construction materials, labors, heavy equipment, supplies, etc., shall be limited to the hours of 8:00 a.m. to 8:00 p.m., weekdays and 9:00 a.m. to 7:00 p.m. weekends and holidays. The Town may authorize, on a case-by- case basis , alternate construction hours. The Applicant shall provide written notice twenty- four (24) hours in advance of modified construction hours. Approval of this request is at discretion of the Town. 28. CONSTRUCTION NOISE: Between the hours of 8:00 a.m. to 8:00 p.m., weekdays and 9:00 a.m. to 7:00 p.m. weekends and holidays, construction, alteration or repair activities shall be allowed. No individual piece of equipment shall produce a noise level exceeding eighty-five (85) dBA at twenty-five (25) feet from the source. If the device is located within a structure on the property, the measurement shall be made at distances as close to twenty-five (25) feet from the device as possible. The noise level at any point outside of the property plane shall not exceed eighty-five (85) dBA. 29. CONSTRUCTION MANAGEMENT PLAN : Prior to the issuance of any permits, the Applicant shall submit a construction management plan that shall incorporate at a minimum the Project Schedule, employee parking, construction staging area and proposed outhouse locations, as applicable. 30 . GOOD HOUSEKEEPING: Good housekeeping practices shall be observed at all times during the course of construction. All construction shall be diligently supervised by a person or persons authorized to do so at all times during working hours. The storing of goods and/or materials on the sidewalk and/or the street will not be allowed unless an encroachment permit is issued by the Engineering Division of the Parks and Public Works Department. The adjacent public right-of-way shall be kept clear of all job related dirt and debris at the end of the day. Dirt and debris shall not be washed into storm drainage facilities. The storing of goods and materials on the sidewalk and/or the street will not be allowed unless an encroachment permit is issued . The Applicant's representative in charge shall be at the job site during all working hours. Failure to maintain th e public right-of-way according to this condition may result in penalties and/or the Town performing the required maintenance at the Applicant's expense. 31. COVERED TRUCKS: All trucks transporting materials to and from the site shall be covered. · 32 . FUTURE STUDIES : Any post-project traffic or parking counts, or other studies imposed by Planning Commission or Town Council shall be funded by the Applicant. TO THE SATISFACTION OF THE SANTA CLARA COUNTY FIRE DEPARTMENT: 33 . FIRE SPRINKLERS: Modification of the existing fire sprinkler system will be required. A State of California licensed (C-16) Fire Protection Contractor shall submit plans, calculations , a completed permit application and appropriate fees to this department for review and approval prior to beginning their work. NOTE : The owner(s), occupant(s), and any contractor(s) or subcontractor(s) are responsible for consulting with the water purveyor of record in order to determine if an y modification or upgrade of the existing water service is required CRC Sec. 313 .2 as adopted and amended by LGTC . 34. WATER SUPPLY REQUIREMENTS : Potable water supplies shall be protected from contamination caused by fire protection water supplies. It is the responsibility of the applicant and any contractors and subcontractors to contact the water purveyor supplying the site of such project, and to comply with the requirements of that purveyor. Such requirements shall be incorporated into the design of any water-based fire protection systems, and/or fire suppression water supply systems or storage containers that may be physically connected in any manner to an applicant capable of causing contamination of the potable water supply of the purveyor of record. Final approval of the system(s) under consideration will not be granted by this office until compliance with the requirements of the water purveyor of record are documented by that purveyor as having been met by the applicant(s). 2010 CFC Sec. 903.3.5 and Health and Safety Code 13114.7. 35 . ADDRESS IDENTIFICATION: New and existing buildings shall have approved address numbers, building numbers, or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabetic letters. Numbers shall be a minimum of 4 inches (101.6 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. 36. CONSTRUCTION SITE FIRE SAFETY: All construction sites must comply with applicable provisions of the CFC Chapter 33 and Standard Detail and Specification SI-7. Provide appropriate notations on subsequent plan submittals, as appropriate to the project. N:\DEV\CONDITIONS\2016\University50Suitel 80.docx This Page Intentionally Left Blank RESOLUTION 2005 -092 RESOLUTION OF THE TOWN COUNCIL OF THE TOWN OF LOS GATOS APPROVING A REQUEST TO MODIFY A CONDITIONAL USE PERMIT FOR A RESTAURANT TO INCREASE THE NUMBER OF SEATS AND DENYING A REQUEST TO INCREASE ALLOWED ENTERTAINMENT CONDITIONAL USE PERMIT: U-03-7 PROPERTY LOCATION: 50 UNIVERSITY AVENUE, SUITE 180 PROPERTY OWNER: FEDERAL REALTY APPLICANT STEVE HAUCK WHEREAS: A . This matter came before Council for public hearing on June 20, 2005 on a recommendation by the Planning Commission, was regularly noticed in conformance with State and Town law and was continued to August 1, 2005 for decision by Council. B. Council received testimony and documentary evidence from the applicant and all interested persons who wished to testify or submit documents. Council considered all testimony and materials submitted, including the record of the Planning Commission proceedings and the packet of material contained in the Council Agenda Reports dated June 15, 2005 and July 28 , 2005, along with subsequent reports and materials prepared concerning this application. C. · The applicant seeks approval to modify an existing conditional use permit for a restaurant to increase the number of seats (from 100 to 140) and to intensify permitted entertainment from unamplified acoustic music Thursdays through Saturdays to amplified music and dancing seven days a week. D. The Planning Commission considered this matter on May 25 , 2005 . Because the application concerns the Town 's Alcohol Policy, the Commission's action constitutes a recommendation to Council. The Commission recommended approving the request to increase the number of seats but to only allow the addition of "amplified acoustic music" in the restaurant. N:\ATY \Resolutions complete\ WINE CELLAR RESO .wpd EXHIBIT 4 E. S'taff presented five (5) alternatives, all of which allowed the reque sted increa se in seating and, regarding entertainment, allowed a range of additional entertainment from the level sought by the applicant to a no change option. Council approves the option that increases the number of seats but does not allow additional entertainment. Council's decision was based in part on the Alcohol Policy that requires the prior adoption of standards and a permit process, which has not occurred, and the applicant's apparent inability to compromise. F . Council finds as follows : 1. As required by Section 15301 of the State Environmental Guidelines as adopted by the Town this project is Categorically Exempt. 2. The provisions of Town Code section 29.20 .190 for granting ofa Conditional Use Permit have been met. In making this finding, Council incorporates herein by this reference the findings of the Planning Commission made on May 25, 2005 in recommending partial approval of this application. RESOLVED: 1. The request to modify Conditional Use Permit U-03-7 i s approved to allow for increase in seating and deny an increase in allowed entertainment. 2. Conditions of approval, attached hereto as Exhibit A, are applied to this Application. 2 . The decision constitutes a final administrative decision pursuant to Code of Civil Procedure section 1094.6 as adopted by section 1.10.085 of the Town Code of the Town of Los Gatos. Any application for judicial relief from this decision must be sought withi n the time limits and pursuant to the procedures established by Code of Civil Procedure section 1094.6, or such shorter time as required by State and Federal Law. PASSED AND ADOPTED at a regular meeting of the Town Council of the Town of Los N:\ATY\Resolutions complete\ WINE CELLAR RESO.wpd 2 • t" • Gatos, California on the l 51h day of August, 2005 , by the following vote . COUNCIL MEMBERS : A YES : Steve Glick.man, Diane McNutt, Joe Pirzynski, Mayor Mike Wasserman . NAYS : None ABSENT : None ABSTAIN: Barbara Spector (Recused) ATTEST: Isl MarLyn J. Rasmussen CLERK ADMINISTRATOR SIGNED: TOWN OF LOS GATOS, CALIFOR.!'J"IA N:\A TY\Resoluti ons complete\ WINE CEL LAR RESO .wpd 3 I sl Mike Wasserman MAYOR OF THE TOWN OF LOS GATOS LOS GATOS, CALIFORNIA CONDITIONS OF APPROVAL ALTERNATIVE 5 50 University Avenue Suite 180 Conditional Use Permit U-03-7 Requesting approval to modify a Conditional Use Permit to legalize the incr.ease in the number of seats, to modify the type of allowed entertainment and to increase the days when entertainment is available on property zoned C-2:PD:LHP. APN 529-02-044 PROPERTY OWNER: Federal Realty APPLICANT: Steve Hauck (Wine Cellar) TO THE SATISFACTION OF THE DIRECTOR OF COMMUNITY DEVELOPMENT (Planning Division) 1. EXPIRATION . Zoning approval will expire two years from the approval date pursuant to Section 29.20 .320 of the Town Code, unless the approval has been vested. 2. SEA TS. The maximum seating allowed is 140 (79 inside dining seats, 15 inside bar seats, and 46 outside dining seats). 3. ALCOHOLIC BEVERAGES. No alcoholic beverages outside of the bar area shall be served without meal service. A meal is defined as a combination of food items selected from a menu (breakfast, brunch, lunch, or dinner). Appetizers such as popcorn, nachos , pretzels, potato skins, relish trays , etc. (hot or cold) are not meals . . 4. UTENSILS . All meals shall be served on reusable utensils. 5 . HOURS OF OPERATION. The hours of operation are as follows: Saturday and Sunday -9:30 AM to 2:00 AM. Monday through Friday-11 :00 AM to 2 :00 AM . 6 . RESTAURANT USE. A quality restaurant and full service bar is permitted. 7 . ENTERTAINMENT. Acoustic musical entertainment is permitted inside only and shall be limited to Thursday, Friday, and Saturday only. There shall be no amplified music inside or outside the restaurant. TO THE SATISFACTION OF THE DIRECTOR OF PARKS AND PUBLIC WORKS: (Engineering Division) 8. TRAFFIC IMPACT MITIGATION FEE (COMMERCIAL) The developer shall pay a proportional to the project's share of transportation improvement needed to serve cumulative development within the Town of Los Gatos. The fee amount will be based upon the Town Council resolution in effect at the time the use permit is issued . The fee shall be paid within 30 days of use permit approval. The traffic impact mitigation fee for this project, using the current fee schedule and the preliminary plaps is $12,300 . This preliminary fee is based on the addition of 40 seats to the existing approved 100-seats. The project will generate 115 additional daily trips (2.86 daily trips per seat), and 11 PM peak hour trips (0.26 peak hour trips per seat). The final fee shall be calculated from the final plans using the rate schedule in effect at the time of the use permit is approved, using a trip generation rate based on high Page 1 of 2 quality restaurant use. TO THE SATISFACTION OF THE POLICE CHIEF: 9. GENERAL. The restaurant/bar is subject to the following: a. Uniformed privately provided security guards may be required in or around the premises by the Chief of Police if alcohol related problems recur that are not re s olved by the licensed owner. b. At the discretion of the Chief of Police, periodic meetings will be conducted with representatives from the Police Department for on-going employee training on alcoholic beverage service to the general public. c . All establishments shall use an employee training manual that addresses alcoholic beverage service consistent with the standards of the California Restaurant Association. d. All licensed operators shall have and shall actively promote a designated driver program such as complimentary non-alcoholic beverages for designated drivers. e. Taxicab telephone numbers shall be posted in a visible location. 10. OUTDOOR DINING. A host/hostess station shall be staffed at the entrance to the outside dining area. Page 2 of 2 This Page Intentionally Left Blank \ I RESOLUTION 2001 -106 RESOLUTION OF THE TOWN COUNCIL OF THE TOWN OF LOS GATOS AMENDING THE TOWN'S ALCOHOLIC ;BEVERAGE POLICY WHEREAS, the sale of alcoholic beverages, if not regulated, can.jeopardize public safety, ,, result in an increase of calls for police services and compromise the quality of life for Town residents; and WHEREAS, The Town Council wants to balance the regulation of alcoholic beverage service and protection of residential neighborhoods with the goal of maintaining a vibrant and successful Downtown and commercial areas throughout Los Gatos ; and WHEREAS, the Town Council held a study session on July 2, 2001 to discuss issues relating to service of alcoholic beverages; and WHEREAS, the Town Council has indicated a desire to review all applications for new alcohol service or change in existing serv~ce, and a need to amend the existing Alcohol Policy, THEREFORE BE IT RESOLVED: the Town Council of the TOWN OF LOS GATOS does hereby adopt the amended Alcoholic Beverage Policy attached hereto as Exhibit A EXIDBIT 5 ! i I -1 I I L Purpose POLICY REGULATING THE CONSUMPTION AND SER VICE OF ALCOHOLIC B E VERAGES The consumption or service of alcoholic beverages, if not regulated , can jeopardize public safety, result in an increase of calls for police services and e-0mpromise the quality of life for Town residents . This policy provides parameters for ale-0holic beverage service, particularly addressing late night service when alcohol related incidents are most likely to occur and when the disturbances to Town residents is least tolerable. The service of alcoholic beverages, with or without meals, past 10 PM is a discretionary privilege to be determined on a case by case basis. The following provisions are intended to balance the protection of residential neighborhoods in close proximity to commercial districts and still maintain the viability of our commercial centers in which restaurants have an essential role. Hours of operation may be regulated based on an establishment's proximity to residential neighborhoods or ~ools, the concentration of establishments in an area serving alcoholic beverages or for other reasons that may arise at the public hearing . · The deciding body may approve a conditional use pennit to serve alcoholic beverages based on the merits of the application and subject to the following requirements : JI. Gene~I policy 1. The Town shall continue to strongly discourage new applications for stand alone bars or restaurants with separate bars . 2 . The Town shall continue to discourage applications for entertainment establishments serving alcoholic beverages. 3. Entertainment in association with an eating or drinking establishment may be allowed if standards and a permit process ar~ adopted. 4. Alcoholic beverage service for new conditional use permit applications or applications for modification of a conditional use permit shall not be allowed: A After 11 PM Sunday through Thursday, except for holidays and evenings before holidays . B . After 1 AM Friday, Saturday, holidays or evenings before holidays . An existing establishment with a conditional use pe~t in good standing allowed to serve alcoholic beverages past the hours stated above may continue to operate under their existing hours of operation. Exhibit A I I I I l \ Town of Los Gatos Alcoholic Beverage Policy Page 2 of4 5 . Any establishment serving alcoholic beverages shall be subject to the following : A Uniformed privately provided security guards may be required in or around the premises by the Chief of Police if alcohol related problems recur that are ·not resolved by the licensed owner. B. At the discretion of the Chi~f of Police, periodic meetings will be conducted with representatives from the Police Department for on-going employee training on alcoholic beverage service to the general ·publi c . . c . All establishments shall use an employee training manual that addresses alcoholic beverage service consistent with the standards of the Californian restaurant Association. D. All licensed operators shall have and shall actively promote a designated driver program such as complimentary non-alcoholic beverages for designated drivers . · E. Taxicab telephone numbers shall be posted in a visible location. 6 . The deciding body shall make the following findings prior to approving an application for conditional use permit to serve alcoholic bever:ages past 1 OPM : A Late night service will not adversely impact adjacent residential neighborhoods. B. The applicant does not have a history of complaints and non-compliance with local ordinances or the Alcoholic Beverage Policy. C. The applicant has demonstrated a clear benefit to the community. 7. A meal is defined as a combination of food items selected from a menu (breakfast , lunch or dinner). Appetizers such as popcorn, nachos, pretzels, potato skins, relish trays , etc. (bot or cold) are not meals. 8. ·Alcoholic beverage service in approved outdoor seating areas may be permitted if adequate separation from public areas is provided as determined by the Town Manager. The separation shall clearly suggest that alcohol is not allowed outside the restaurant seating area. ORDINANCE 2025 ORDINANCE OF THE TOWN OF LOS GATOS AMENDING THE ZONING ORDINANCE EFFECTING A ZONE CHANGE FROM C-2 LHP TO C-2 PD LHP AT 50 UNIVERSITY A VENUE THE TOWN COUNCIL OF THE TOWN OF LOS GATOS DOES ORDAIN AS FOLLOWS : SECTION I The Town C ode of the Town of Los Gatos is hereby amended to change the zoning at 50 University A venue shown on the map which is attached hereto marked Exhibit A and is part of this Ordinance from C-2 LHP (Central Business Disrricr -Landmark Historic Preservation) to C-2 PD LHP (Central Business District -Planned Development -Landmark Historic Preservation). SECTION II The PD (Planned Development Overlay) zone established by this Ordinance authorizes the following construction and use of improvements: 1. Demolition of the Steamer 's building and numerous accessory structures (shown on the Official Development Plan, sheet 3) and the partial demolition and reconstruction of the Old Town Center. The Old Town Center will be considered demolished by Town Code (defmition of demolition of an historic structure) since more than 25 percent of the from exterior walls will be removed, and more than 50 percent of all exterior walls will be removed . The building however , will not be demolished and interior walls will remain; 2 . Construction of an underground parking garage with retail above, new commercial building adjacent to St. Luke 's Church (20 University Avenue), and reconfigurati on of the parking lot as shown on the Official Development Plan ; N :•SHARE\A TY 121 6.1 2 EXHIBIT 6 3. Changing the use of the auditoriwn to a retail use. A theater use is a permitted use within the existing auditorium, the amphitheater or elsewhere on the site; 4. Landscaping , streets and other improvements shown and required on the Official Development Plan; 5 . a . Relocation of the Steamer's restaurant to another space within the project site , subject to the conditions of Steamer's most current Conditional Use Permit [216 seats]. b . The existing restaurants (Wine Cellar -Suite 12 [49 seats]; California Cafe - Suite 8 [208 seats]; and the Waves (or new tenant) -Suite 1 [91 seats]), are permitted to remain in the existing Old Town Center building subject to their conditions of their Conditional Use Permit; any changes to their use or relocation within the Center on either side of University Avenue or increase in seating, will require a modification to the applicable Conditional Use Permit. 6 . Uses permitted are those specified in the C-2 (Central Business District) zone by Sections 29 .60.320 (Permitted Uses) and 29.20.185 (Conditional Uses) of the Town Code , as those sections exist at the time of the adoption of this Ordinance , or as they may be amended in the future. However, no use listed in Section 29 .20 .185 is allowed unless specifically authorized by this Ordinance, or by Conditional Use Permit . SECTION III COMPLIANCE WITH OTHER DEVELOPMENT STANDARDS All provisions of the Town Code apply , except when the Official Development Plan specifically shows otherwise . N :\SHARE \A T Y 12 I 6 . I 2 2 SECTION IV Architecture and Site Approval is required before there are exterior changes to the Old Town Center, demolition of the Steamer's building and construction work of the parking lot , new buildings and reconstruction of the Old Town Center is performed, whether or not a permit is required for the work and before any permit for construction is issued. Construction permits shall only be in a manner complying with Section 29 .80 .130 of the Town Code. Interior work of the Old Town Center is pennitted to bring the building up to current Building Code and does not need Architecrure and Site approval. A Building Permit and other applicable pennits may be required for the interior work. SECTION V The attached Exhibit A (Map) and Exhibit B (Tentative Map and Development Plans, 20 sheets), are part of the Official Development Plan . The following must be complied with before issuance of any grading, demolition or construction permits : TO THE SATISFACTION OF THE PLANNING DIRECTOR : (Planning Section) 1 . PARCEL. The parcel shall remain as one parcel. 2 . HOLD HARMLESS . The developer has requested the Town's approval and has had the opportunity to review , comment and accept the process and approval. The developer shall hold the Town harmless from any claim or litigation alleging that this ordinance or subsequent approvals obtained by the developer for this project was processed, adopted, or approved in violation of any Federal, State, Town or other local law or regulation of any kind, and shall pay all costs involved in defending any such claim or litigation, including attorney fees. 3 . PHASING . All buildings may be worked on simultaneously . Twenty Five percent of the occupancy of Building E shall be held until final occupancy has been given for the existing N:\SHARE\A TY 1216 .12 3 Old Town Center and its two parking lots. A map shall be provided prior to the issuance of a building permit, indicating the tenant spaces of Building E and which units are proposed to have their occupancy held . During the final occupancy stage, these held units may be changed with Town approval. 4 . TRASH ENCLOSURE/MECHANICAL EQUIPMENT. Trash enclosures and mechanical equipment shall be located as far from residential receptors as possible . The enclosures shall be constructed to provide full screening from residential receptor locations. The location of the trash enclosures will be reviewed during the Architecture and Site approval process. The quietest and smallest capacity heating, ventilation, and air conditions equipment that meets design specifications and Town Noise Ordinance standards shall be used. The roof equipment for Building D shall be restricted to the east end of the building and the vent exhausts shall be directed toward the Old Town parking lot. 5 . ACCESS EASEMENT. If the trash pickup is proposed at Parking Lot 6, an access easement shall be required to be obtained from the Town, prior to Architecture and Site approval. If the easement is not granted, the revised trash pickup area shall be considered during the Architecture and Site approval process which may require redesign and/or reduction of building square footage . 6. RECYCLING. AU wood, metal, glass, and aluminum materials generated from the demolished structure shall be deposited to a company which will recycle the materials . Receipts from the company(s) accepting these materials, noting type and weight of material, shall be submitted to the Town prior to the Town's demolition inspection. 7. STEAMER'S. The outside seating area for the relocated Steamer's restaurant, will be reviewed during the Architecture and Site approval process to ensure it meets all Town Code and Town policy requirements . 8. CLOSED AREAS. All areas to be closed off within the existing Old Town Center shall be explicitly documented to ensure that these areas will not and cannot be used in the future during the Architecture and Site approval process. This documentation of the N:\SHARE\A TY 1216.12 4 closed areas shall be shown on the Architecture and Site plans and building pennit plans. These areas shall visually be shown to be closed off during final inspection . 9 . PLAQUES. The two plaques which currently exist on the building , (the history of L os Gatos plaque and the dedication to teachers and students plaque), shall be saved and replaced on the building prior to final occupancy. 10 . PARKING SPACES . All parking spaces shall conform to current parking requirement dimensions. Parking spaces in the underground garage next to columns , walls or similar obstructions, shall have a minimum width of 9 .5 feet. Parking plans will be reviewed during the Architecture and Site approval process . 11 . RESTROOMS . The restrooms located within the buildings , which are not elusively for an individual office use , shall be available to the general public . 12 . BUILDING D. The back wall (south side next to church) shall be painted to match or harmonize with the existing St. Luke's wall . 13 . BUILDING D ACCESS . Access to the space between Building D and the St. Luke 's wall may be securely closed to the public and accessible only to the appropriate and permitted maintenance/landscaping personnel . 14 . WALL. The proposed 10 foot high wall along the south property line adjacent to St. Luke's Church shall not be constructed . The existing eight foot high wall shall remain . If the church later decides that the wall is needed, and the applicant wishes to install the wall , it shall be permitted with the appropriate approvals and permits from the Town. 15. BUILDING E . During the Architecture and Site approval process , Building E shall be modified as follows: a. Open up the center pathway. Building could be moved closer to the south property line to increase width of pathway . b. Design structure so that it appears to be a collective of individual structures that abut each other . N :\SHA RE\A TY 1216.12 5 c . The roof design shall be reflective of the individual structures (break-up rooflines). d. Comer tower shall be redesigned into a clipped comer design . e . Provide more variety in the buildings . 16. STORE DELIVERIES . The area behind Building E, adjacent to Parking Lot 6, shall not be used for deliveries. 17 . SIGNS. A sign program shall be submitted as part of the Architecture and Site approval process . Arched wrought iron signs advertising Old Town are permitted as shown on the attached Development Plans (Exhibit B). The margin of measurement for tenant signs may be reduced to a minimum of one inch around all of the words and symbols. The actual dimensions shall be finalized during the Architecture anci Site approval process with the sign program. Signs identifying business and the Center shall not be either lighted from the interior or made of translucent materials. (Engineering Section) 18. PUBLIC IMPROVEMENTS. The following improvements shall be installed by the developer. Plans ·for those improvements shall be prepared by a California registered civil engineer, reviewed and approved by the Town, and guaranteed by contract, Faithful Performance Security and Labor & Materials Security before the issuance of a building permit or recordation of a map. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. At the time of Architecture and Site Approval for the project, conformance with the Streetscape Plan for Central Business District Improvements (which ·includes benches and trash receptacles) will be determined and incorporated with the improvements identified below. N:\S HARE\A TY 12 16.12 6 a . University Avenue . Curb , gutter, "Villa Hermosa" sidewalk, curb ramp , driveway approach, street lights, tie-in paving, removal of mid-block crosswalks , signing , striping , storm and sanitary sewers, as required . b . Elm Street. Curb , gutter, "Villa Hermosa" sidewalk, curb ramp , street lights, tie- in paving , signing , striping , storm and sanitary sewers , as required. c . Mullen Avenue . Curb , gutter, "V illa Hermosa" sidewalk , curb ramp , drive way approach, street lights, tie-in paving, signing, striping, storm and sanitary sewers, as required . 19 . HYDRAULIC CALCULATIONS . At the time of the final design of the project, existing and post-project hydraulic calculation for the project area and associated drainage conveyance facilities between the project and Los Gatos Creek. The hydraulic calculation should include calculations to confirm the preliminary findings of the EIR. 20 . MID-BLOCK CROSSWALK. The existing mid-block cross walks shall be removed. No new mid-block crosswalk shall be installed . The only marked crosswalk to the site shall be at the Elm Street/University Avenue intersection and across Mullen Avenue at University Avenue. 21 . INSURANCE. One million dollars ($1,000,000) of liability insurance holding the Town hannless shall be provided in a format acceptable to the Town Attorney before issuance of the building permit. 22 . TRAFFIC IMPACT MITIGATION FEE (COMMERCIAL). The developer shall pay a proportional to the project's share of transportation improvements needed to serve cumulative development within the Town of Los Gatos . The fee amount will be based upon the Town Council resolution in effect at the time the building permit application is made. The number of trips used in the calculations will be the net additional trips as shown in Table 5-8 of the E .I.R. by Geier & Geier , dated September 1996. The fee shall be paid before iss uance of the building permit. The traffic imp act mitigation fee for this project using the current fee sc hedule is $89,280 . The final fe e s hall be calculated fr om N :\SHARE\A TY 12 16 .12 7 the final plans using the rate schedule in effect at the time of the building permit application. 23. CHRISTMAS SHOPPING CONSIDERATIONS . Construction shall be scheduled or other measures implemented, to minimize construction impacts during the Christmas shopping season. 24. DEWATERING PLAN. Prior to issuance of a building pennit, the project applicant shall prepare a dewatering plan specifying how groundwater would be handled when encountered during excavation, how temporary excavations would be protected from groundwater saturation and how permanent foundations would be kept dry from groundwater as well as from surface water runoff. 25 . EROSION CONTROL PLAN. The project applicant shall prepare and implement an erosion control plan in conformance with the Town and California Regional Water Quality Control Board requirements prior to issuance of a building pennit. The plan shall account for existing drainage conditions since most runoff generated on the sunken parking lot site during the excavation phase would be too low to drain to adjacent storm drains and would require pumping. 26 . STREET LIGHTING. The project applicant shall prepare and submit to the Town during the Architecture and Site approval process, a street lighting program and plan for all streets surrounding the proposed project site. 27. TRAFFIC DIVERTER. At the time of Architecture and Site Application, various methods of preventing Old Town related traffic from using Edelen Avenue from Mullen Avenue shall be explored. The method of traffic diversion chosen shall also be approved by Central Fire Protection District. N :\SHARE\A TY 1216.12 8 TO THE SATISFACTION OF THE DIRECTOR OF PARKS , FORESTRY & MAINTENANCE SERVICES: 2 8 . TREE CARE. All tree care activities shall be acc omplished by a licensed , competent tree care firm as approved by and under the supervision of the Director of Parks , Forestry & Maintenance Services . 29 . PROTECTIVE FENCING . Prio r to any construction or Building Permits being is sued , the applicant shall meet with the Director of Parks , Forestry and Maintenance Services c o ncerning the need for protective fencing around the existing trees. Such fencing is to be installed prior to , and be maintained during construction. 30. NEW TREES . Newly planted trees shall be double-staked , using rubber tree ties and shall be planted prior to acceptance of the subdivi s ion . 31 . IRRIGATION . No irrigation or planting shall be permitted under the drip line of existing native trees. All newly planted mater ial shall be irrigated by an in-ground irrigation system. 32 . CONSTRUCTION . No construction or grading shall take place within the dripline of existing trees. 33. AERATION TUBES. Any impervious area (excluding ro adways) encroaching under the dripline of existing trees shall have aeration tubes installed. 34 . LANDSCAPE PLAN. A precise landscaping plan shall be submitted at the Architecrure and Site Approval stage of development. Planting on the south back of Building D shall be done in cooperation with St. Luke's Church. 35 . WATER EFFICIENCY . This project is subject to the Town's Water Efficient Landscape Ordinance as per Chapter 26 Anicle IV of the Town C ode. A review fee based on current resolution shall be paid when the land scape , irri gation plans and water calculatio ns are submitted for review . Plans and fees must be submitted prior to is su ance of a building permit. N :\SHARE\ATY I 2 16 .12 9 36. ARBORIST REQUIREMENTS. The following measures from the Coate study (1996) shall be enforced to minimize damage to the three Oak trees: a. The foundation which is installed ten feet from the fence , beginning 50 feet east of the curb, must be of pier and beam foundation design, not standard L -footing. b. If an additional wall is installed adjacent to the existing property line wall , it shall also be of a pier and grade beam foundation design with the beam laid on top of the existing grade. c. When pavement is removed from any area beneath the canopy of one of these trees, the pavement must be removed by breaking the pavement up with a jackhammer or by manual labor, and the broken pieces shall be loaded into a skip loader which is . standing on undisturbed pavement. Roots which are exposed in the top three inches of soil, with removal of that pavement, shall be protected from compaction or other damage. d. Under no circumstances shall equipment be allowed to drive on the exposed soil once the pavement has been removed until protection has been installed over the newly exposed roots . e . The protective surfaces shall include a four inch layer of tree chips over any surface beneath the tree canopy which is newly exposed. f . If it becomes necessary to drive construction equipment over any of those newly exposed areas, 1.5 inch plywood sheets shall be laid over a five inch layer of tree chips to prevent compaction of the soil by equipment wheels. g . As part of the contract specifications for the general contractor and all subcontractors, construction personnel shall not be allowed to prune any of the Oak tree limbs or branches located direly above construction. An arborist certified by the International Society of Arboriculture shall be called to prune the canopy of the trees over the parking lot before N:\S HARE \A TY 12 16 .12 10 construction begin begins, if any conflicts arise between actual construction and the tree at later stages of construction, only the arborist shall be allowed to do additional pruning to solve the problem. All pruning must follow Western Chapter, International Society of Arboriculrure Pruning Standards . h . The two Oak trees located closest to University Avenue shall be fenilized by injecting a liquid fenilizer mix into all areas beneath the canopies of these trees , including that on the south side of the existing wall . The fertilizer shall be composed of Greenbelt 22-14-14 soluble fertilizer mixed at four pounds of fertilizer per 100 gallons of water, and injected at 10 gallons of this mix per one inch of trunk diameter into all areas beneath the canopy in exposed soil or through bricks where that becomes the only method by which fertilizer can be supplied to the root zone . TO THE SATISFACTION OF THE DIRECTOR OF BUILDING AND ENGINEERING SERVICES: 37. GENERAL . All public improvements shall be made according to the latest adopted Town Standard Drawings and the Standard Specifications for Public Works Construction. All work shall conform to the applicable Town ordinances . Adjacent public right-of-way shall be kept clear of all job related dirt and debris at the end of day . Dirt and debris shall not be washed into storm sewers . The storing of goods and materials on the sidewalk and /or street will not be allowed unless a special permit is issued. The developer 's representative in charge shall be at the job site during all working hours . Failure to maintain the public right-of-way according to this condition may result in the Town performing the required maintenance at the developer's expense. 38 . PUBLIC WORKS INSPECTIONS . The de veloper or his re presentative shall notify the Engineering Constructio n Inspector at least twenty-four (24) hours before starting any N :\SHARE\A TY 1216 .12 11 work pertaining to on-site drainage facilities , grading, or paving; and all work in the Town's right-of-way. Failure to do so will result in rejection of work that went on without inspection. 39. EROSION CONTROL (COMMERCIAL). Interim and final erosion control plans shall be prepared and submitted to the Engineering Development Section of the Planning Department. On sites over 5 acres, at Notice of Intent (NOD and Storm Water Pollution Prevention Plan (SWPPP) shall be submitted to the Region Water Quality Control Board. Grading activities shall be Limited to the period of least rainfall (April 15 to October 1). A maximum of two weeks is allowed between clearing of an area and stabilizing/building on this area if grading that is allowed to go on during the rainy season. In addition, straw bales and plastic sheeting shall be stored on-site for emergency control, if needed. Install filter berms, check dams, retention basins, silt fences, and straw bale dikes as needed on the project site, to protect downstream water quality during winter months . 40. UTILITIES. The developer shall install all utility service, including telephone, electric power, and other communications lines underground, as required by Town Code §27.50 .015(b). 41. RESTORATION OF PUBLIC IMPROVEMENTS. The developer shall repair or replace all existing improvements not designated for removal that are damaged or removed because of developer's operations. Improvements such as, but not limited to, curbs, gutters, sidewalks, driveways, signs , pavements, raised pavement markers, thermoplastic pavement markings, or ·signs shall be repaired and replaced to a condition equal to or better than the original condition. Existing improvements to be repaired or replaced shall be at the direction of the Engineering Construction Inspector, and shall comply with all Title 24 Disabled Access provisions . Developer shall request a walk-through with the Engineering Construction Inspector before the start of construction to verify existing conditions . N:\SHARE\A T Y12 I 6.12 12 42 . CURB RAMPS . The developer shall construct three or four (3 or 4) curb ramps according to State Standard Drawings at the crosswalks at University A venue /Elm Street , University Avenue/Mullen Avenue and the University Avenue entrance. The exact number will be determined at the time of Architecture and Site Approval. The actual "Case " as shown on the standard to be used will be decided by the Engineering Construction Inspector during the construction phase . 43 . AS-BUILT PLANS. After completion of the construction of all work in the public right- of-way or public easements, the original plans shall have all changes (change orders and field changes) clearly marked. The "As-built" plans shall again be signed and "wet- stamped" by the engineer who prepared the plans, attesting to the changes. The original "As-built" plans shall be reviewed and approved the Engineering Inspector . A photo Mylar of the approved "As-built" plans shall be provided to the TOWN before the release of the Faithful Performance Security. 44. DRIVEWAY APPROACH. The developer shall install four (4) Town Standard Commercial driveway approaches in the locations shown on the Official Development Plan. The new driveway approaches shall be constructed per Town Standard Detail S-5 . 45. ENCROACHMENT PERMIT. All work in the public right-of-way will require a Construction Encroachment Permit and will require construction security . 46 . GARAGE ACCESS RAMP. The garage access ramp shall be widened to 30 feet. This will facilitate ingress and egress from the garage and allow the placement of a parking control station in the future. The ramp shall be clearly signed to prohibit pedestrian use . 47 . BUILDING "E" PARKING. The underground garage can be used for construction worker parking once the Town Building Official has finaled the private use of the garage . In addition, the entrance to the parking garage shall be monitored at all time that it is open (e .g ., guard, gate , etc.) to ensure it is not used by the public prior to the issuance of a Certificate of Occupancy for Building "E". N :\SHAR.E\A T Y 12 16.12 13 48. PARKING CONTINGENCY PLAN. The applicant shall prepare a construction worker parking contingency plan, to be implemented if directed to do so by the Town, to have construction workers park off-site. The plan shall include designation of a specific off-site location for all construction worker parking. This location shall not be within the Central Business District (C-2 zone) unless Town Council gives the authorization to a specific site, and workers shall be shuttled from the off-site location. The parking contingency plan shall be approved by the Director of Building and Engineering Services prior to the issuance of a building permit. 49. CONSTRUCTION DELIVERIES . All construction deliveries shall be restricted to the hours between 9:00 a.m. and 3:00 p .m . to minimize school and downtown impacts. The applicant should monitor construction activities to ensure that traffic flow along University are not adversely affected by materials/equipment deliveries. At no time shall street blockages be pennitted that would impact the mobility of emergency service vehicles. 50. PEDESTRIAN ACCESS . Construction activities shall be planned and implemented so as to minimize disruption to pedestrian and vehicular traffic . The sidewalk shall be kept open on at least one side of each street at all times. 51. SANITARY SEWER LATERAL. Sanitary sewer laterals shall be televised by West Valley Sanitation District at the developer's expense and approved by the Town of Los Gatos before they are used or reused. Install sanitary sewer lateral clean-outs at the property line. 52. GREASE TRAPS . Meet all requirements of the County Health Department and West Valley Sanitation District for the interception, separation, or pretreatment of effluent for all existing and new uses. 53 . NOISE REDUCTION. Equipment used for project construction shall utilize control techniques (improved mufflers, equipment redesign, use of silencers, ducts and mufflers) in order to minimize construction noise impacts . Construction noise shall be minimized by requiring the project contractors to agree with the following measures : N :\SHARE\A TY 1216.12 14 a. If the Noise Ordinance noise standard cannot be met at the Mullen Avenue property boundary or along the church boundary, temporary wooden fencing shall be erected during construction along that boundary. b . A member of the project applicant's team shall be appointed to enforce construction hours allowed by Town Ordinance . The project applicant shall introduce this person to the T own staff and have this person accessible to the Town during all site preparation and construction activities. c. Elimination of unnecessary idling of equipment. d . Good maintenance and lubrication procedures shall be used on all construction equipment to reduce operating noise . 54 . HAZARDOUS MATERIALS PLAN. A management plan for hazardous materials shall be prepared by the developer. This management plan shall identify all suspected hazardous materials (including contaminated soils, groundwater, PCBs , lead-based paints , asbestos) and specify applicable regulations that would determine appropriate handling and disposal of hazardous materials. The management plan shall provide detailed quantification of the types and quantities of asbestos. The plan shall also provide guidelines for the handling and disposal of lead-based paints. When handling and disposing of lead-based paints, appropriate measures shall be required to ensure compliance with applicable state hazardous waste and OSHA regulations (worker safety). The plan shall include plans for site safety/worker protection, sampling and investigation, and disposal/remediation for materials which exceed regulatory action levels and are determined to be hazardous . For suspected hazardous materials (contaminated soil and groundwater) which may be encountered during construction, contingency plans for site safety /worker protection, sampling and investigation, and disposal/remediation shall be included; these shall be based on soil and groundwater sampling and testing that have been completed to date . The plan shall be filed with the Town and all other appropriated agencies. Appropriate contract specifications shall be imposed on construction contractors N:\SHA.RE\ATY 1216 .12 15 for proper handling and disposal of hazardous materials consistent with the required management plan. The developer shall complete an asbestos survey of the Steamer's building prior to demolition . The developer shall ensure that all existing asbestos containing materials are removed , closed off or encapsulated by a licensed abatement contractor prior to site preparation for renovation , rehabilitation and removal of any materials or fixrures. This will include undertaking a physical examination of the project site to determine the amount of each type of material to be closed off, encapsulated or removed , and mapping areas where asbestos containing materials are to be closed off, encapsulated and/or removed . An inspection and maintenance 'program shall be developed for any areas closed off or encapsulated to prevent any fiber release. 55. HAZARDOUS MATERIAL PREPARATION. During demolition and excavation activities, the developer shall be prepared for the potential of encountering hazardous materials in areas not already characterized. The developer shall be alerted for visible evidence of hazardous materials, such as soil discoloration , suspicious odors, or presence of underground tanks, piping or other buried building materials and shall provide for the collection of grab samples in the area of suspected contamination. 56 . GROUNDWATER. If groundwater is encountered during project construction and dewatering is required , the developer shall undertake sampling and testing of the encountered groundwater in accordance with the contingency sampling and investigation plan. If groundwater is found to contain contaminants which exceed regulatory action levels, it may not be discharged into the existing storm drain system. Removal and handling of the contaminated groundwater shall be done in a manner acceptable to the Regional Water Qual ity Control Board , the Town and other jurisdictional agencies . Once more detailed project plans become available , the Town may choose to require the de veloper to submit a Notice of Intent (NOI) to the California Regional Water Quality Co ntrol Board prior to construction. If required , the NOi letter shall include mapping , N :\SHARE\A T Y 12 16 .12 16 potential pollutant lists, and a detailed description of drainage factors regarding the project site during construction. 57 . ELEVATOR CONTAMINANTS. The existence of contaminants in soil beneath the existing elevator room shall be determined and appropriate remediation shall be completed as required by applicable federal , state and local regulations . Appropriate contract specifications shall be imposed on construction contractors for proper handling and disposal of hazardous materials consistent with the required management plan. 58. PCB 'S. The developer shall request PG&E to test the two transformers for PCBs and if present , PCBs shall be removed and disposed of properly . 59 . NOTIFICATION REQUIREMENTS. The developer shall comply with notification requirements under applicable Federal regulations regarding hazardous air pollutants, including asbestos , in accordance with Section 19827. 5 of the California Health and Safety Code (adopted January 1, 1991). 60 . EXISTING BASEMENT. While the existing hazard posed in the crawl hole basement area of Building B is not an impact of the proposed project, this area shall be immediately be closed off or abated and the soil decontaminated by a licensed abatement contractor (prior to initiation of any work on the proposed project). In the event the crawl hole basement of this area is permanently closed off, an inspection and maintenance program shall be developed to prevent any fiber release . 61. ASBESTOS EXPOSURE . All necessary measures shall be implemented to protect operating merchants, employees and customers from exposure to asbestos . 62 . BAAQMD. To comply with BAAQMD nuisance abatement rules , the following dust (PMlO) control measures shall be included as conditions of the grading permit : a. Water all active construction areas at least twice daily. b . C o ver all trucks hauling soil , sand , and other loose debris o r require all trucks to maintain at least tw o feet of freeboard. N :\SHARE\A TY 12 16 .12 17 c . Apply water three times daily, or apply (non-toxic) soil stabilizers on all unpaved access roads, parking areas, and staging areas at construction sites. d. Sweep (preferably with water sweepers) all paved access roads, parking areas and staging areas at construction sites . e . Sweep streets daily {preferably with water sweepers) if visible soil material is carried onto adjacent public streets . 63 . GEOLOGIC HAZARDS CHECKLIST . The developer shall submit to the Town a Geologic Hazards Checklist, as outlined by the California Department of Conservation Division of Mines and Geology, and appropriate geotechnical design studies demonstrating that the probable lateral forces experienced at the project site from a seismic event have been taken into consideration in the design and construction plans for the proposed project. These studies shall address building foundation design for the parking garage and Buildings D and E as well as for any seismic retrofit found to require new or upgraded foundations in Buildings A and B. Project plans for seismic retrofitting of Buildings A and B shall demonstrate conformance with 1994 Uniform Building Code requirements (including 1995 California amendments) and/or recommendations made by Boley Consulting Engineers, whichever requirements are determined to be appropriate by the Town. 64. SEISMIC RETROFIT . The developer shall provide plans or designs for structural repairs in order to seismically retrofit the existing buildings . Such plans or designs shall include any and all foundations needed to support each location of seismic retrofitting . Proposed plans shall conform to the current Uniform Building Code, with California amendments in effect in Town. 65 . BUILDING CODE. Project plans shall demonstrate conformance with current Uniform Building Code requirements (including California amendments in effect in Town) and/or recommendations made by Boley Consulting Engineers (whichever requirements are determined to be appropriate by the Town) to repair and upgrade the structures in order N:\SHARE\ATYI2 16.12 18 to integrate the structural system and to make Buildings A and B capable of providing resistance to gravity and seismic loads. 66 . The westerly wall of the underground garage under Building E shall contain a structurally designed section or sections that would structurally accommodate being knocked out for access to and from a possible future below-grade parking level on Town Parking Lot No . 6. TO THE SATISFACTION OF CENTRAL FIRE PROTECTION DISTRICT 67 . SPRINKLERS . Fire sprinkler system shall be modified as necessary for Buildings A, B and C. An automatic fire sprinkler system shall be installed in Buildings D and E and the parking garage . 68 . HYDRANTS. Additional fire hydrants may be required. This will be determined during the Architecture and Site approval process . TO THE SATISFACTION OF THE CHIEF OF POLICE 69. LIGHTING. The stairwells and building recesses shall have proper lighting with illumination no less than five foot candles at five feet off the ground. If telephones are provided, they shall be located in the open courtyard, not hidden away behind walls. TO THE SATISFACTION OF SANT A CLARA COUNTY WATER DISTRICT 70 . DRAINAGE. There shall be no overbank drainage into the Los Gatos Creek from grading the site. Storm runoff shall be collected via an onsite storm drain system and distributed to an existing city storm drain system or an outfall into the creek. If an outfall is desired, it shall be designed in accordance with District guide sheets . N :\SHARE\.A. TY 121 6.12 19 71. PERMIT . A District permit is required for any construction adjacent to or within the Los Gatos Creek . SECTION VI This Ordinance was introduced at a regular meeting of the Town Council of the Town of Los Gatos on December 2 , 1996, and adopted by the following vote as an ordinance of the Town of Los Gatos at a meeting of the Town Council of the Town of Los Gatos on December 16 , 1996. This ordinance takes effect 30 days after it is adopted. COUNCIL MEMBERS : AYES: Steven Blanton, Jan Hutchins, Randy Attaway Vice Mayor Linda Lubeck NAYS: None ABSENT: Mayor Joanne Benjamin ABSTAIN : SIGNED: VICE MAYOR OF THE TOWN OF LOS GATOS LOS GATOS, CALIFORNIA ATTEST: \ ·OLtct£~ Gw \\~_// CLERK OF THE TOWN OF L~ATOS LOS GATOS, CALIFORNIA N :\S HARE\A TY 1216 .12 20 This Page Intentionally Left Blank use will not be detrimental to public health, safety, or general welfare, and it operates within the General Plan since the use is already present with the Central Business Distr ict. Sincerelv., __ /--~~~ ~Kehl Mark Engl ish Architects 415-391-0186 Joshua@markenglisharchitects .com April 14, 2016 Town of Los Gatos 110 E . Main St. Los Gatos, CA 95030 RE: Old Town Shopping Center Wine Cellar Expansion To Whom It may Concern, RECE IVED JUN 0 7 20 16 TOWN OF LOS GATOS PLANNING D!'ilSION 356 Santana Row, Suite 1005 San Jose, CA 95128 PH: 408.551.-4600 FX: 408.551.A618 Federal Realty Investment Trust ("Landlord") for the above referenced project has approved Wine Cellar (Tenant) to submit a CUP modification application with the Town of Los Gatos for the expansion into the existing basement area of the building located at 50 University Ave. Detailed drawings will be submitted to Landlord and to the Town of Los Gatos for review and approval of such use of additional space. Landlord agrees to allow Tenant to add 60 additional seats in the expansion area and the use of up to 20 additional parking spaces. Please contact our office should you have any questions. Sincerely, SRI Old Town, LLC By Federal Realty Investment Trust Jessica Rose Project Manager-Tenant Services jrose@federalrealty.com 408-551-2253 EXHIBIT -9 This Page Intentionally Left Blank PAGE2 MAYOR AND TOWN COUNCIL SUBJECT: DISCUSS AND ADOPT THE POLICY COMMITTEE'S RECOMMENDATION FOR AN ENTERTAINMENT POLICY JUNE 13, 2016 DISCUSSION: Entertainment is often desired by restaurants, cafes, retailers, and other merchants as an enhancement of the environment for their patrons while within the confines of their location. When responsibly executed, entertainment may provide merchants with the opportunity to attract customers, create a more desirable experience, build return customer base, and market the products and services provided. Especially in the setting of downtown or shopping centers, entertainment can provide a draw for customers who then park once and patronize multiple merchant locations. Staff commonly receives requests from merchants for the ability to provide entertainment including poetry readings; open microphone nights; live music for brunch and/or evening dinner service; and grand openings or anniversary sales. The merchants have requested entertainment to occur during the businesses' normal operating hours and within the confines of their merchant location. Given that these requests are not directly associated with ~lcohol beverage consumption, staff concurs with the Policy Committee's recommendation to separately regulate entertainment and alcohol beverage consumption, and adopt a policy addressing entertainment at this time to allow businesses to enhance their operations during the upcoming summer and suosequent warmer weatlief irionThs. This action fs c·onsistent -Witn the ToWfi ~Counci1 's previously adopted Strategic Priority to strengthen the Town's economic vitality and providing businesses with greater opportunity for customer attraction and retention. For the purpose of this report and the proposed policy, entertainment is defined as follows : Entertainment means any activity conducted for the primary purpose of diverting or e ntertaining perso ns in a premises open to th e general public. Such entertainment may include, but shall not be limited to, live musical p erforman ces, instrumental or vocal, dance acts, concerts, live shows, amplified music or sound, dancing, DJ, karaoke, jam sessions, and/or other s imilar activities. In addition, this proposed policy also identifies any entertainment occurring after 10:00 p .m . as late night entertainment, and describes it as a discretionary privilege and is not to be construed to be a right of development nor run with the land. The Policy Committee recommends that the Town Council to adopt a policy that is simple for businesses and staff to implement, monitor, and enforce. In the attached draft policy, entertainment that is in compliance with the currently adopted noise ordinance defined in Section 16 .20.25 of the Town Code regulating Commercial and Industrial zones would be allowed by right before 10:00 p.m. (Attachment 2). Any establishment intending to have any entertainment or amplified noise after 10:00 p .m. would be required to obtain an entertainment permit as outlined in Attachment 1. PAGE4 MAYORANDTOWNCOUNC~ SUBJECT: DISCUSS AND ADOPT THE POLICY COMMITTEE'S RECOMMENDATION FOR AN ENTERTAINMENT POLICY JUNE 13 , 2016 DISCUSSION (Continued): the Planning Commission . Fees for tis process would be the same as any application that is heard at these levels. The DRC application is currently $3,982 .23 , the Planning Commission application fee is $6,545.46 Permit Review and Renewal The Policy Committee and staff recommend that any late night entertainment permit expire immediately upon the change of ownership and not run with the land as CUPs do. The Council may also elect to include a mandatory review cycle or renewal period for each late night entertainment permit issued. Review and renewal could be processed at a staff level with Town Manager approval for applications without code compliance complaints on file . Enforcement With both entertainment and late night entertainment, the Code Compliance Division allcl/or tlie Polke Department would f61low uj) oil concerns and inve-stigate possible violations . Multiple founded violations could result in suspension or revocation of a late night entertainment permit, and/or review and possible revocation of the establishment's CUP. CONCLUSION/NEXT STEPS: The Council is asked to discuss and adopt the Policy Committee 's recommendation for an Entertainment Policy allowing entertainment by right before 10:00 p.m. given compliance with the currently adopted noise ordinance is met, and allowance for late night entertainment after 10:00 p .m . with an approved permit. Should the Town Council choose to adopt the attached draft policy as written, or with modifications, consideration and direction should also be given on the following: • The allowance for multiple CUP modifications to be brought forward to the deciding bodies together, rather than each business being required to file separately. Businesses would still have the option to file separately, and in both instances, provide direction that businesses may have only the condition pertaining to entertainment reviewed and modified. • The review and renewal periods for late night entertainment permits including the dec iding body for initial approval and review/renewal cycles . PAGE3 MAYORANDTOWNCOUNC~ SUBJECT: DISCUSS AND ADOPT THE POLICY COMMITTEE'S RECOMMENDATION FOR AN ENTERTAINMENT POLICY JUNE 13 , 2016 DISCUSSION (Continued): With the recommended separation of entertainment from late night entertainment, the Policy Committee discussed how these regulations could be implemented and enforced as they relate to the following: Existing Conditional Use Permits (CUPs) Those establishments with existing CUPs that do not have conditions specifically allowing entertainment fall into three categories: those with a CUP that is silent on entertainment; those with a CUP that states they must comply with the Town's provisions on entertainment; and those with a CUP that denies the ability to have entertainment and/or amplified sound. For the first two categories of CUPs, the businesses would be able to observe the new regulations upon the adoption of the proposed policy. In contrast, the last category, those with disallowances of live entertainment and/or amplified sound would need to come through the public process for a CUP modification. The Council may elect to direct staff to allow such businesses to do one or both of the following: • Offer businesses the option to modify their CUPs as a group, which would allow them to be heard with other businesses, reducing the processing time and cost. • Offer businesses wishing to modify this condition, the opportunity to have only the condition pertaining to entertainment and/or amplified sound considered and not open their entire CUP for review or modification. The deciding body for the modification would be the same as what was required for the original CUP approval (i.e., establishments with alcohol would require a Town Council hearing for consideration and approval of a CUP modification while minor restaurants may be heard at either the Development Review Committee or Planning Commission levels). Late Night Entertainment Permit When considering a late night entertainment permit for businesses, Section I of the attached draft policy outlines the review process. The Policy Committee recommends that the Development Review Committee be the deciding body for late night entertainment permits with appeal rights to the Planning Commission and Town Council. If it is the desire of the Council, an alternative approving body could be identified such as PAGE5 MAYOR AND TOWN COUNCIL SUBJECT: DISCUSS AND ADOPT THE POLICY COMMITTEE 'S RECOMMENDATI ON FOR AN ENTERTAINMENT POLICY JUNE 13, 2016 COORDINATION: This report was coordinated with the Town Attorney's and Town Manager's Offices and the Community Development Department. ENVIRONMENTAL ASSESSMENT: The adoption of the proposed policy is not a project under the California Environmental Quality Act. Attachments: 1. Draft Entertainment Policy 2 . Section 16 .20.025 of the Town Code pertaining to noise in Commercial and Industrial zones. This Page Intentionally Left Blank LOCATION: APN: CONDITIONAL USE PERMIT: APPLICABLE CODES: ZONE: HIGH FIRE ZONE: OCCUPANCY GROUP: CONSTRUCTION TYPE: FIRE SPRINKLERS: YEAR BUILT: SQUARE FOOTAGEEXISTING:PROPOSED: TOTAL: 50 UNIVERSITY AVENUE, SUITE 180LOS GATOS, CA 95030 529-02-044 U-03-07 2013 CALIFORNIA BUILDING CODE 2013 CALIFORNIA RESIDENTIAL BUILDING CODE2013 CALIFORNIA ELECTRICAL CODE2013 CALIFORNIA MECHANICAL CODE2013 CALIFORNIA PLUMBING CODE2013 CALIFORNIA ENERGY CODE2013 CALIFORNIA FIRE CODE2013 CALIFORNIA GREEN BUILDING CODE2013 TITLE-24 WITH THE TOWN OF LOS GATOS AMENDMENTS C-2:LHP:PD NO A-2, V-N (NEW AND EXISTING) YES 1974 3,186 SQ FT 2,661 SQ FT 5,847 SQ FT 1,780 SQ FT 881 SQ FT GRAPHIC SYMBOLS LEGEND: (E) WALL TO REMAIN (E) WALL TO DEMOLISH (N) WALL (N) 1-HR FIRE WALL (N) DOOR, (E) TO REMAIN WITHOUT TAG (N) WINDOW, (E) TO REMAIN WITHOUT TAG DIMENSION ## X #'-##" # A#.# # A#.# # A#.# # ELEVATION SECTION DETAIL MARKER REVISION PR O J E C T N O T E S , I N D E X , E T C A0.0 1/4" =1'-0" MEJRK PROJECT DATA: PROJECT DESCRIPTION INTERIOR REMODEL AND INTERIOR EXPANSION OF AN EXISTING QUALITY RESTAURANT IN A BASEMENT INTO AN EXISTING BASEMENT OF AN EXISTING BUILDING. 20 PARKING STALLS HAVE BEEN APPROVED FOR USE ALLOWING FOR 60 ADDITIONAL (N) SEATS PER THE RATIO 3 SEATS OF (N) SEATING PER 1 (N) PARKING STALL. THE 60 SEATS WILL BE DISTRIBUTED IN TWO NEW DINING/BANQUET AREAS. THE (E) 140 SEATS WILL BE REALLOCATED WITHIN THE (E) RESTAURANT SPACE. (E) BAR SEATS WILL BE REDUCED BY 5, (E) INSIDE DINING SEATS WILL BE REDUCED BY 7, AND OUTSIDE DINING SEATS WILL BE INCREASED BY 12 FOR A NET ZERO CHANGE IN (E) SEATS WITHIN THE (E) RESTAURANT. MetalMetal FrameManufacturerMinimumMirrorMiscellaneousManufacturer SuppliedMullionMultiple NewNorthNortheastNot In ContractNot To ScaleNorthwestNumberNominal OverOn CenterOutside DiameterOriented Strand BoardOfficeOverhangOpeningOpposite PolePublic AddressPrecast Concrete or Pipe ColumnPre-fabricated TrussPanel HardwareProperty LinePlastic LaminatePressure TreatedPressure Treated Douglas FirPerforatedPerpendicularPlatePlate heightPlanPlywoodPanelPaintPolishedPairPrefabricatedPoint Quart Riser or RightRight HandRoof JoistRough OpeningRubber TileRain Water LeaderRadiusRound or RoadReceptacleReferenceRefrigerator(tion)(ant)ResilientRevisionRoofRafterRoomResawn (Rough Sawn)RubberRedwood SecondSouthShelfSupply AirSupply Air GrillSolid CoreSoutheastSee Civil DrawingsSee Electrical DrawingsSingle GlazedSingle HungSee Kitchen DrawingsSee Landscape DrawingsSheet MetalSee Mechanical DrawingsSheet Metal ScrewSee Plumbing DrawingsSee Structural DrawingsSanitary Sewer or Select StructuralSheet VinylSouthwest, Shear Wall, or Stem WallShowerSheetSheathingSimilarSinkSkylightSlidingSlab on gradeSpecificationsSpeakerSquareSquare Foot/FeetSquare YardStreet or StoneStainless SteelStationarySteelStorageSuspendedSymmetrical Tread, Top or TemperedTop and BottomTongue and GrooveTowel Bar or Telephone BoardTrash CompactorTo be determinedTo be selectedTop of BeamTop of Curb or ConcreteTop of Finish FloorTop of Plate or Top of PavementTop of Roof SheathingTop of SteelTop of SubfloorTop of Stem WallTop of WallToe NailToilet Room AccessoriesTube SteelTelephoneTemporaryTerrazzoThickToiletTypical Uniform Building Code Unless Otherwise NotedUndercutUrinal Vinyl Composition TileVerify In FieldVinyl Sash WindowVinyl TileVerticalVinyl West, Watt or WidthWithWithoutWater Closet or Wall CoveringsWood Frame or Wide FlangeWaterproof or Work PointWaterproof MembraneWater ResistantWeather-strippingWood Sash WindowWelded Wire MeshWasherWoodWindowWeight Yard MET. or MTL.MF.MFR.MIN.MIR.MISC.MS.MUL.MULT. (N)N.N.E.N.I.C.N.T.S.N.W.NO. or #NOM. O/O.C.O.D.O.S.B.OFF.OH.OPNG.OPP. P.P.A.P.C.P.F.T.P.H.P.L.P. LAM.P.T.P.T.D.F.PERF.PERP.PL. or P.PL. HGT.PLN.PLYWD.PNL.PNT.POL.PR.PREFAB.PT. QT. R.R.H.R.J.R.O.R.T.R.W.L.RAD. or R.RD.RECP.REF.REFR.RESIL.REV.RF. or R.RFT.RM.RS.RUB.RWD. (") S.S. or SH.S.A.S.A.G.S.C.S.E.S.C.D.S.E.D.S.G.S.H.S.K.D.S.L.D.S.M.S.M.D.S.M.S.S.P.D.S.S.D.S.S.S.V.S.W.SHR.SHT.SHTNG.SIM.SK.SKLT.SL.S.O.G.SPECS.SPKR.SQ.SQ. FT. or S.F.SQ. YD.SST.ST.STA.STL.STOR.SUSP.SYM. T.T. & B.T. & G.T.B.T.C.T.B.D.T.B.S.T.O.BM.T.O.C.T.O.F.F.T.O.P.T.O.R.T.O.S.T.O.S.F.T.O.S.W.T.O.W.T.N.T.R.A.T.S.TEL.TEMP.TER.THK.TLT.TYP. U.B.C.U.L.U.O.N.UC.UR. V.C.T.V.I.F.V.S.W.V.T.VERT.VYL. WW/W/OW.C.W.F.W.P.W.P.M.W.R.W.S.W.S.W.W.W.M.WASH.WD.WDW.WT. YD. ABBREVIATIONS &@ABV.A.F.F.A.B.A.C.A.D.A.F.A.S.A.S.W.A.T.A.V.APPROX.ARCH. B.B.O.BM.B.O.C.B.O.S.BLKG.BLW.B.F.F.BM.BTM. C. or C.W.CON. JT.C.J.C.L.C.M.U.C.P.C.T.CAB.CANT.CLG.CLG. HGT.CLO.CLR.COL.CONC.COND.CONT.CORR.CPT.CSMT.CTR(D)CW D.F.D.H.DBL.DEG.DEPT.DET.DIA.DIAG.DIM.DISP.DN.DR.DRY.DS.DW.DWG(S)DWR, D. E.B.E.N.E.W.EA.ELEC.ELEV.EQ.EQUIP.ETC.EXIST. (E)EXP. JT.or E.J.EXT. F.A.U.F.D.F.E.F.F.F.H.S.F.J.F.M.F.O.C.F.O.F.F.O.M.F.O. PLYWD.F.O.S.F.S.FAB.FNDN.FIN.FIX.FLR.FLUOR.FRT.FTG.FURR. G.D.G.F.I.G. RAIL.G.S.M.GA.GAL.GALV.GAR.GL. B.GLULAM. or G.L.GYP. BD.or G.W.B. H. or H.W. H., HT. or HGT.H.C.H.M.H. RAIL.H.V.A.C. HB.HDR.HDWD.HOR. I.C.I.D.IN. or "INCAD.INFO.INSUL.INT. J.B.JAN.JT. or J.JST. or J. K.D.KIT.KP. L.F.L.S.LAM.LAV.LB. or # LKR.LNDY.LVR. (')M.B.M.C.M.D.O.M.R.M.S.MATL.MAX.MECH.MEMB. andatAboveAbove finish floorAnchor BoltAsphalt ConcreteArea DrainAluminum StorefrontAs SpecifiedAluminum Sash WindowAcoustical TileAudio/VisualApproximateArchitectural or Arched Base or BottomBottom of BeamBottom of ConcreteBottom of SteelBlockingBelowBelow finish floorBeamBottom Cold WaterConstruction Joint or Control JointCeiling JoistCenter LineConcrete Masonry UnitCement PlasterCeramic TileCabinetCantileverCeilingCeiling heightClosetClearColumnConcreteCondenserContinuousCorridorCarpetCasementCenter(ed)Curtain Wall Penny (nails)Drinking Fountain or Douglas FirDouble HungDoubleDegreeDepartmentDetailDiameterDiagonalDimensionDisposalDownDoor or DrainDryerDownspoutDishwasherDrawing(s)Drawer Expansion BoltEdge NailEach WayEachElectricalElevationEqualEquipmentEt ceteraExistingExpansion JointExterior Forced Air UnitFloor DrainFire ExtinguisherFinish FloorFlat Head ScrewFloor JoistFoam MoldingsFace of ConcreteFace of FinishFace of MasonryFace of PlywoodFace of StudsFloor SinkFabricateFoundationFinishFixture or FixedFloorFluorescentFire-Retardant TreatedFootingFurring Garbage DisposalGround Fault InterrupterGuard RailingGalvanized Sheet MetalGage, GaugeGallonGalvanizedGarageGlass BlockGlue LaminatedGypsum Board Hot WaterHeightHollow CoreHollow MetalHandrailHeating, Ventilation and Air ConditioningHose bibHeaderHardwoodHorizontal In ContractInside DiameterInchIncandescentInformationInsulationInterior Junction BoxJanitorJointJoist Kiln DriedKitchenKickplate or King Post Linear FootLag ScrewLaminateLavatoryPoundLockerLaundryLouver MinuteMachine BoltMedicine CabinetMedium Density OverlayMoisture ResistantMachine ScrewMaterialMaximumMechanicalMembrane DISCLAIMER: ALL EXISTING DIMENSIONS SHOWN ARE FIELD MEASUREMENTS TAKEN BY THE ARCHITECT'S OFFICE. THE ARCHITECT DOES NOT MAKE ANY WARRANTY, EXPRESSED OR IMPLIED OR ASSUME ANY LEGAL LIABILITY OR RESPONSIBILITY FOR THE ACCURACY OR COMPLETENESS OF THE EXISTING DIMENSIONS. PROJECT SITE N 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. GENERAL NOTES: ALL WORK SHALL COMPLY WITH THE 2013 CALIFORNIA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE WITH STATE OF CALIFORNIA AMENDMENTS), 2013 CALIFORNIA ELECTRICAL CODE (BASED ON THE 2011 NEC WITH AMENDMENTS), 2013 CALIFORNIA PLUMBING CODE (2012 UPC WITH AMENDMENTS), 2013 CALIFORNIA MECHANICAL CODE (2012 UMC WITH AMENDMENTS), 2013 CALIFORNIA ENERGY CODE, AND 2013 CALIFORNIA FIRE CODE (CFC) AND WHEN APPLIES, THE 2013 CALIFORNIA RESIDENTIAL CODE (2012 INTERNATIONAL RESIDENTIAL CODE). CONTRACTOR SHALL COMPLY WITH ANY OTHER STANDARD OR CODE IN EFFECT AS OF DATE OF CONTRACT DOCUMENTS. DO NOT SCALE DRAWINGS. FIGURED DIMENSIONS SHALL BE FOLLOWED. LARGE SCALE DRAWINGS OR DETAILS TAKE PRECEDENCE OVER SMALL SCALE ONES. SPECIFIC NOTES AND DETAILS TAKE PRECEDENCE OVER TYPICAL NOTES AND DETAILS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DIMENSIONAL DISCREPANCIES. BEFORE STARTING ANY PORTION OF WORK, THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VISIT THE SITE AND BE KNOWLEDGEABLE OF CONDITIONS THEREIN. ALL EXISTING CONDITIONS THAT HAVE BEARING ON HIS WORK. ARCHITECT IS TO BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES BETWEEN FIELD CONDITIONS, DRAWINGS, SPECIFICATIONS, OR OTHER CONTRACT DOCUMENTS. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR CORRECTING ANY WORK THAT WAS KNOWINGLY COMMENCED WITHOUT FIRST NOTIFYING THE ARCHITECT AND THE OWNER. THEY SHALL INVESTIGATE, VERIFY AND BE RESPONSIBLE FOR ALL CONDITIONS OF THE PROJECT AND SHALL NOTIFY THE ARCHITECT OF ANY CONDITION REQUIRING MODIFICATION BEFORE PROCEEDING WITH WORK. CONTRACTOR SHALL COORDINATE ALL MECHANICAL, PLUMBING, ELECTRICAL CIVIL, STRUCTURAL AND ARCHITECTURAL WORK. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO PROCEEDING WITH WORK. NO EXTRA COMPENSATION SHALL BE ALLOWED FOR EXTRA WORK RESULTING FROM LACK OF COORDINATION BETWEEN TRADES. CONTRACTOR SHALL PROVIDE PUBLIC PROTECTION AS REQUIRED BY CITY AND COUNTY REQUIREMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ANY TEMPORARY BRACING TO INSURE THE SAFETY OF THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR CUTTING, FITTING AND PATCHING AS REQUIRED TO MAKE THE SEVERAL PARTS FIT TOGETHER PROPERLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING SEPARATE PERMITS FOR ELECTRICAL, MECHANICAL, PLUMBING, GRADING OR OTHER PERMITS AS MAY BE REQUIRED BY LOCAL AUTHORITIES. ISSUANCE OF A BUILDING PERMIT BASED ON THESE DRAWINGS DOES NOT CONSTITUTE GRANTING OF THESE SEPARATE PERMITS. THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR AND EQUIPMENT REQUIRED FOR THE FULL PERFORMANCE OF THE WORK HEREIN, UNLESS SPECIFICALLY NOTED OTHERWISE. ALL WORK SHALL BE PERFORMED IN A GOOD AND WORKMAN-LIKE MANNER AND CONFORM TO ALL PERTINENT REGULATIONS AND INSTRUCTIONS. ALL WORK SHOWN IS TO BE CONSTRUCTED OF NEW MATERIAL U.O.N. INSTALLATION AND/OR MAINTENANCE DIRECTIONS PROVIDED BY THE MANUFACTURER SHALL BE FOLLOWED FOR ALL MATERIALS U.O.N. ALL ITEMS MARKED (E) ARE EXISTING AND (N) ARE NEW. ALL WALLS AND CEILINGS SHALL BE 5/8" GYPSUM WALL BOARD (GWB) UNLESS OTHERWISE NOTED. AT WALLS SEPARATING GARAGE FROM HOUSE AND ENCLOSED USABLE SPACE BENEATH STAIRS SHALL BE ONE-HOUR FIRE RESISTANT 5/8" TYPE 'X' GWB. AT WET AREAS SHALL BE WATER RESISTANT GWB (GREEN BOARD). SEE FINISH SCHEDULE FOR GYP. BRD. FINISH LEVELS. NO EXTRA COMPENSATION SHALL BE ALLOWED FOR EXTRA WORK RESULTING FROM LACK OF COORDINATION BETWEEN TRADES. ALL KNOWN UNDERGROUND CONDITIONS HAVE BEEN SHOWN, THE CONTRACTOR SHOULD EXERCISE CAUTION WHEN EXCAVATING TO AVOID DAMAGE TO (E) UNDERGROUND PIPE, CONDUITS, ETC.,WHICH ARE TO REMAIN. SITE NOTES: 1. 2. 3. PUBLIC RIGHT OF WAY SHALL BE KEPT CLEAN AND FREE OF DEBRIS FOR THE DURATION OF THE PROJECT. GENERAL CONTRACTOR RESPONSIBLE FOR DAILY SWEEPING DAILY. GENERAL CONTRACTOR RESPONSIBLE FOR COORDINATION OF SHUTDOWN AND REMOVAL OF (E) UTILITIES w/ CITY OF SAN FRANCISCO DEPARTMENT OF PUBLIC HEALTH AND ANY ASSOCIATED AGENCIES AS REQUIRED. GENERAL CONTRACTOR RESPONSIBLE FOR PUBLIC AND SITE SAFETY AT ALL TIMES. VICINITY MAP NTS 50 U N I V E R S I T Y A V E N U E LO S G A T O S C A 9 5 0 3 0 AP N # : 5 2 9 - 0 2 - 0 4 4 PR O J E C T N U M B E R : V - 0 5 DRAFTED BY: THE DESIGN AND IDEAS REPRESENTED ON THIS SHEET ARE THE PROPERTY OF MARK ENGLISH ARCHITECTS. ANY UNAUTHORIZED USE WITHOUT WRITTEN PERMISSION IS PROHIBITED. COPYRIGHT MARK ENGLISH ARCHITECTS, 2013. REVISIONS: NO. DATE DESCRIPTION CLIENT APPROVALSIGNATURE: CHECKED BY: PRINT DATE: SCALE: E ma r k @ m a r k e n g l i s h a r c h i t e c t s .c o m TH E W I N E C E L L A R DISCLAIMER: ALL NEW AND EXISTING DIMENSIONS SHOWN ARE BASED ON CAD BACKGROUNDS PROVIDED BY THE CLIENT & FIELD MEASUREMENTS TAKEN BY THE ARCHITECT'S OFFICE. THE ARCHITECT DOES NOT MAKE ANY WARRANTY, EXPRESSED OR IMPLIED OR ASSUME ANY LEGAL LIABILITY OR RESPONSIBILITY FOR THE ACCURACY OR COMPLETENESS OF THE EXISTING DIMENSIONS. 07.14.2016 7/31/13 2016.07.11 PLANNING RESUBMITTAL1 SHEET INDEX A0.0A1.0A1.1A2.1A2.2 PROJECT NOTES, INDEX, ETCEXISTING SITE PLANEXISTING BASEMENT & PATIO PLANPROPOSED BASEMENT & PATIO PLANPROPOSED BASEMENT & PATIO PLAN: OCCUPANCY & EGRESS 1. 2. 3. 4. 5. 6. 7. DEMOLITION NOTES: CONTRACTOR SHALL PROTECT ALL EXISTING CONSTRUCTION TO REMAIN FROM DAMAGE DURING DEMOLITION. CONTRACTOR SHALL PATCH AND / OR REPAIR ALL EXISTING ADJACENT CONSTRUCTION AS REQUIRED AFTER DEMOLITION TO PROVIDE A COMPLETE AND FINISHED INSTALLATION. CONTRACTOR SHALL DEMOLISH AND / OR REMOVE ALL ITEMS AS INDICATED ON THE DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL DEBRIS CAUSED BY DEMOLITION AND OTHER DEBRIS IN THE BUILDING. CONTRACTOR SHALL CLEAN UP DAILY AND SHALL NOT ALLOW AN EXCESSIVE AMOUNT OF DEBRIS TO ACCUMULATE AT ANY TIME. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND LEGAL DISPOSAL OF ALL ITEMS, MATERIALS, ETC. DEMOLISHED FROM PROPERTY. WHERE EXISTING LIGHT FIXTURES, ELECTRICAL OUTLETS, ETC. ARE TO BE REMOVED, ALL SERVICE TO SAME SHALL BE CAPPED OR REMOVED IN ACCORDANCE WITH ALL APPLICABLE CODES. WHERE EXISTING MECHANICAL CHIMNEY, DUCTWORK, ETC. IS TO BE DEMOLISHED CONTRACTOR TO PROTECT EQUIPMENT AND DUCTWORK TO REMAIN. PROJECT TEAM OWNER: ARCHITECT: STEVE HAUCK50 UNIVERSITY AVENUE, STE 180LOS GATOS, CA 95030TEL: 408.354.4808 MARK ENGLISHMARK ENGLISH ARCHITECTS250 COLUMBUS AVE. #200SAN FRANCISCO CA 94133TEL: 415.391.0186 SEATING ANALYSIS: EXISTING SEATING:BAR:15 SEATSINSIDE DINING:79 SEATSOUTSIDE DINING: 46 SEATS 140 SEATS PROPOSED SEATING:BAR:10 SEATS (-5)INSIDE DINING:72 Seats (-7)OUTSIDE DINING: 58 Seats (+12) (N) DINING AREA 2: 16 SEATS(N) DINING AREA 3: 44 SEATSSUBTOTAL OF (N) SEATS:60 SEATS 200 SEATSPARKING ANALYSIS: EXISTING PARKING:BELOW GRADE PARKING:108 STALLSON-SITE PARKING:112 STALLS 220 STALLSPARKING DISTRICT:300 STALLS APPROVED USE 20 STALLSOF (E) STALLS: NOTES: 1. TOTAL PARKING CREDIT BASED ON PARKING ASSESSMENT DISTRICT AT 60% BUILD-OUT2.PARKING IS SHARED WITH SURROUNDING BUSINESSES WITHINTHE OLD TOWN CENTER. SEE SITE PLAN ON SHT A1.0. 1 USE ANALYSIS: (E) AREA FORMERLYLEASED BY 'BORDER'SBOOKS' TO BERENOVATED: (E) ELECTRICAL ANDMAINTENANCE AREA TO BE RENOVATED: 1. 2. 3. FIRE SUPPRESSION NOTES: REVIEW OF THIS DEVELOPMENTAL PROPOSAL IS LIMITED TO ACCEPTABILITY OF SITE ACCESS AND WATER SUPPLY AS THEY PERTAIN TO FIRE DEPARTMENT OPERATIONS, AND SHALL NOT BE CONSTRUED AS A SUBSTITUTE FOR FORMAL PLAN REVIEW TO DETERMINE COMPLIANCE WITH ADOPTED MODEL CODES. PRIOR TO PERFORMING ANY WORK THE APPLICANT SHALL MAKE APPLICATION TO, AND RECEIVE FROM, THE BUILDING DEPARTMENT ALL APPLICABLE CONSTRUCTION PERMITS. FIRE SPRINKLERS: MODIFICATION OF EXISTING FIRE SPRINKLER SYSTEM WILL BE REQUIRED. A STATE OF CALIFORNIA LICENSED (C-16) FIRE PROTECTION CONTRACTOR SHALL SUBMIT PLANS, CALCULATIONS, A COMPLETED PERMIT APPLICATION AND APPROPRIATE FEES TO THE DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO BEGINNING THEIR WORK. NOTE: THE OWNER(S), OCCUPANT(S) AND ANY CONTRACTOR(S) OR SUBCONTRACTOR(S) ARE RESPONSIBLE FOR CONSULTING WITH THE WATER PURVEYOR OF RECORD IN ORDER TO DETERMIN E IF ANY MODIFICATION OR UPGRADE OF THE EXISTING WATER SERVICE IS REQUIRED CRC SEC. 313.2 AS ADOPTED AND AMENDED BY LGTC WATER SUPPLY REQUIREMENTS: POTABLE WATER SUPPLIES SHALL BE PROTECTED FROM CONTAMINATION CAUSED BY FIRE PROTECTION WATER SUPPLIES. IT IS THE RESPONSIBILITY OF THE APPLICANT AND ANY CONTRACTORS AND SUBCONTRACTORS TO CONTACT THE WATER PURVEYOR SUPPLYING THE SITE OF SUCH PROJECT, AND TO COMPLY WITH THE REQUIREMENTS OF THE PURVEYOR. SUCH REQUIREMENTS SHALL BE INCORPORATED INTO THE DESIGN OF ANY WATER-BASED FIRE PROTECTION SYSTEMS, AND/OR FIRE SUPPRESSION WATER SUPPLY SYSTEMS OR STORAGE CONTAINERS THAT MAY BE PHYSICALLY CONNECTED IN ANY MANNER TO AN APPLIANCE CAPABLE OF CAUSING CONTAMINATION OF THE POTABLE WATER SUPPLY OF THE PURVEYOR OF RECORD. FINAL APPROVAL OF THE SYSTEM(S) UNDER CONSIDERATION WILL NOT BE GRANTED BY THIS OFFICE UNTIL COMPLIANCE WITH THE REQUIREMENTS OF THE WATER PURVEYOR OF RECORD ARE DOCUMENTED BY THAT PURVEYOR AS HAVING BEEN MET BY THE APPLICANT(S). 2010 CFC SEC. 903.3.5 AND HEALTH AND SAFETY CODE 13114.7 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. CONDITIONS: GENERAL: ALL PUBLIC IMPROVEMENTS SHALL BE MADE ACCORDING TO THE LATEST ADOPTED TOWN STANDARD PLANS, STANDARD SPECIFICATIONS AND ENGINEERING DESIGN STANDARDS. ALL WORK SHALL CONFORM TO THE APPLICABLE TOWN ORDINANCES. THE ADJACENT PUBLIC RIGHT-OF-WAY SHALL BE KEPT CLEAR OF ALL JOB-RELATED DIRT AND DEBRIS AT THE END OF THE DAY. DIRT AND DEBRIS SHALL NOT BE WASHED INTO STORM DRAINAGE FACILITIES. THE STORING OF GOODS AND MATERIALS ON THE SIDEWALK AND/OR TH STREET WILL NOT BE ALLOWED UNLESS AN ENCROACHMENT PERMIT IS ISSUED. THE APPLICANT'S REPRESENTATIVE IN CHARGE SHALL BE AT THE JOB SITE DURING ALL WORKING HOURS. FAILURE TO MAINTAIN THE PUBLIC RIGHT-OF-WAY ACCORDING TO THIS CONDITION MAY RESULT IN THE TOWN PERFORMING THE REQUIRED MAINTENANCE AT THE APPLICANT'S EXPENSE. CHANGE OF OCCUPANCY: PRIOR TO INITIAL OCCUPANCY AND ANY SUBSEQUENT CHANGE IN USE OR OCCUPANCY OF ANY NON-RESIDENTIAL CONDOMINIUM SPACE, THE BUYER OR THE NEW OR EXISTING OCCUPANT SHALL APPLY TO THE COMMUNITY DEVELOPMENT DEPARTMENT AND OBTAIN APPROVAL FOR USE DETERMINATION AND BUILDING PERMIT AND OBTAIN INSPECTION APPROVAL FOR ANY NECESSARY WORK TO ESTABLISH THE USE AND/OR OCCUPANCY CONSISTENT WITH THAT INTENDED. PARKING: ANY PROPOSED PARKING RESTRICTION MUST BE APPROVED BY THE TOWN OF LOS GATOS, COMMUNITY DEVELOPMENT DEPARTMENT. TRAFFIC IMPACT MITIGATION FEE: THE APPLICANT SHALL PAY THE PROJECT'S PROPORTIONAL SHARE OF TRANSPORTATION IMPROVEMENTS NEEDED TO SERVE CUMULATIVE DEVELOPMENT WITHIN THE TOWN OF LOS GATOS. THE FEE AMOUNT WILL BE BASED UPON THE TOWN COUNCIL RESOLUTION IN EFFECT AT THE TIME THE BUILDING PERMIT IS ISSUED. THE FEE SHALL BE PAID BEFORE ISSUANCE OF A BUILDING PERMIT. THE FINAL TRAFFIC IMPACT MITIGATION FEE FOR THIS PROJECT SHALL BE CALCULATED FROM THE FINAL PLANS USING THE CURRENT FEE SCHEDULE AND RATE SCHEDULE IN EFFECT AT THE TIME THE BUILDING PERMIT IS ISSUED, USING A COMPARISON BETWEEN THE EXISTING AND PROPOSED USES. CONSTRUCTION STREET PARKING: NO VEHICLE HAVING A MANUFACTURE'S RATED GROSS VEHICLE WEIGHT EXCEEDING TEN THOUSAND (10,000) POUNDS SHALL BE ALLOWED TO PARK ON THE PORTION OF A STREET WHICH ABUTS PROPERTY IN A RESIDENTIAL ZONE WITHOUT PRIOR TO APPROVAL FROM THE TOWN ENGINEER. CONSTRUCTION HOURS: ALL SUDIVISION IMPROVEMENTS AND SITE IMPROVEMENTS CONSTRUCTION ACTIVITIES, INCLUDING THE DELIVERY OF CONSTRUCTION MATERIALS, LABORS, HEAVY EQUIPMENT, SUPPLIES, ETC., SHALL BE LIMITED TO THE HOURS OF 8:00 A.M. TO 8:00 P.M., WEEKDAYS AND 9:00 A.M. TO 7:00 P.M. WEEKENDS AND HOLIDAYS. THE TOWN MAY AUTHORIZE, ON A CASE-BY-CASE BASIS, ALTERNATE CONSTRUCTION HOURS. THE APPLICANT SHALL PROVIDE WRITTEN NOTICE TWENTY-FOUR (24) HOURS IN ADVANCE OF MODIFIED CONSTRUCTION HOURS. APPROVAL OF THIS REQUEST IS AT DISCRETION OF THE TOWN. CONSTRUCTION NOISE: BETWEEN THE HOURS OF 8:00 A.M. TO 8:00 P.M., WEEKDAYS AND 9:00 A.M. TO 7:00 P.M. WEEKENDS AND HOLIDAYS, CONSTRUCTION, ALTERATION OR REPAIR ACTIVITIES SHALL BE ALLOWED. NO INDIVIDUAL PIECE OF EQUIPMENT SHALL PRODUCE A NOISE LEVEL EXCEEDING EIGHTY-FIVE (85) dBA AT TWENTY-FIVE (25) FEET FROM THE SOURCE. IF THE DEVICE IS LOCATED WITHIN THE STRUCTUREON THE PROPERTY, THE MEASUREMENT SHALL BE MADE AT DISTANCES AS CLOSE TO TWENTY-FIVE (25) FEET FROM THE DEVICE AS POSSIBLE. THE NOISE LEVEL AT ANY POINT OUTSIDE OF THE PROPERTY PLANE SHALL NOT EXCEED EIGHTY-FIVE (85) dBA. CONSTRUCTION MANAGEMENT PLAN: PRIOR TO ISSUANCE OF ANY PERMITS, THE APPLICANT SHALL SUBMIT A CONSTRUCTION MANAGEMENT PLAN THAT SHALL INCORPORATE AT A MINIMUM THE PROJECT SCHEDULE, EMPLOYEE PARKING, CONSTRUCTION STAGING AREA AND PROPOSED OUTHOUSE LOCATIONS, AS APPLICABLE. GOOD HOUSEKEEPING: GOOD HOUSEKEEPING PRACTICES SHALL BE OBSERVED AT ALL TIMES DURING THE COURSE OF CONSTRUCTION. ALL CONSTRUCTION SHALL BE DILIGENTLY SUPERVISED BY A PERSON OR PERSONS AUTHORIZED TO DO SO AT ALL TIMES DURING WORKING HOURS. THE STORING OF GOODS AND/OR MATERIALS ON THE SIDEWALK AND/OR THE STREET WILL NOT BE ALLOWED UNLESS AN ENCROACHMENT PERMIT IS ISSUED BY THE ENGINEERING DIVISION OF THE PARKS AND PUBLIC WORKS DEPARTMEN. THE ADJACENT PUBLIC RIGHT-OF-WAY SHALLE BE KEPT CLEAR OF ALL JOB RELATED DIRT AND DEBRIS AT THE END OF THE DAY. DIRT AND DEBRIS SHALL NOT BE WASHED INTO STORM DRAINGAGE FACILITIES. THE STORING OF GOODS AND MATERIALS ON THE SIDEWALK AND/OR THE STREET WILL NOT BE ALLOWED UNLESS AN ENCROACHMENT PERMIT IS ISSUED. THE APPLICANT'S REPRESENTATIVE IN CHARGE SHALL BE AT THE JOBSITE DURING ALL WORKING HOURS. FAILURE TO MAINTAIN THE PUBLIC RIGHT-OF-WAY ACCORDING TO THIS CONDITION MAY RESULT IN PENALTIES AND/OR THE TOWN PERFORMING THE REQUIRED MAINTENANCE AT THE APPLICANT'S EXPENSE. COVERED TRUCKS: ALL TRUCKS TRANSPORTING MATERIALS TO AND FROM THE SITE SHALL BE COVERED. FUTURE STUDIES: ANY POST-PROJECCT OR PARKING COUNTS, OR OTHER STUDIES IMPOSED BY PLANNING COMMISSION OR TOWN COUNCIL SHALLL BE FUNDED BY THE APPLICANT. 1 1 N (N) AREA OF REMODEL AND EXPANSION INTO (E) BASEMENT SPACE.EX I S T I N G S I T E P L A N 1/32" =1'-0" MEJRK 50 U N I V E R S I T Y A V E N U E LO S G A T O S C A 9 5 0 3 0 AP N # : 5 2 9 - 0 2 - 0 4 4 PR O J E C T N U M B E R : V - 0 5 DRAFTED BY: THE DESIGN AND IDEAS REPRESENTED ON THIS SHEET ARE THE PROPERTY OF MARK ENGLISH ARCHITECTS. ANY UNAUTHORIZED USE WITHOUT WRITTEN PERMISSION IS PROHIBITED. COPYRIGHT MARK ENGLISH ARCHITECTS, 2013. REVISIONS: NO. DATE DESCRIPTION CLIENT APPROVALSIGNATURE: CHECKED BY: PRINT DATE: SCALE: E ma r k @ m a r k e n g l i s h a r c h i t e c t s .c o m TH E W I N E C E L L A R DISCLAIMER: ALL NEW AND EXISTING DIMENSIONS SHOWN ARE BASED ON CAD BACKGROUNDS PROVIDED BY THE CLIENT & FIELD MEASUREMENTS TAKEN BY THE ARCHITECT'S OFFICE. THE ARCHITECT DOES NOT MAKE ANY WARRANTY, EXPRESSED OR IMPLIED OR ASSUME ANY LEGAL LIABILITY OR RESPONSIBILITY FOR THE ACCURACY OR COMPLETENESS OF THE EXISTING DIMENSIONS. 07.14.2016 7/31/13 2016.07.11 PLANNING RESUBMITTAL1 EXISTING SITE PLAN Scale: 1/32" = 1'-0" 1 A1.0 0 32 64 FT A1.0 EX I S T I N G B A S E M E N T & P A T I O P L A N 1/8" =1'-0" MEJRK 50 U N I V E R S I T Y A V E N U E LO S G A T O S C A 9 5 0 3 0 AP N # : 5 2 9 - 0 2 - 0 4 4 PR O J E C T N U M B E R : V - 0 5 DRAFTED BY: THE DESIGN AND IDEAS REPRESENTED ON THIS SHEET ARE THE PROPERTY OF MARK ENGLISH ARCHITECTS. ANY UNAUTHORIZED USE WITHOUT WRITTEN PERMISSION IS PROHIBITED. COPYRIGHT MARK ENGLISH ARCHITECTS, 2013. REVISIONS: NO. DATE DESCRIPTION CLIENT APPROVALSIGNATURE: CHECKED BY: PRINT DATE: SCALE: E ma r k @ m a r k e n g l i s h a r c h i t e c t s .c o m TH E W I N E C E L L A R DISCLAIMER: ALL NEW AND EXISTING DIMENSIONS SHOWN ARE BASED ON CAD BACKGROUNDS PROVIDED BY THE CLIENT & FIELD MEASUREMENTS TAKEN BY THE ARCHITECT'S OFFICE. THE ARCHITECT DOES NOT MAKE ANY WARRANTY, EXPRESSED OR IMPLIED OR ASSUME ANY LEGAL LIABILITY OR RESPONSIBILITY FOR THE ACCURACY OR COMPLETENESS OF THE EXISTING DIMENSIONS. 07.14.2016 7/31/13 2016.07.11 PLANNING RESUBMITTAL1 EXISTING LOWER LEVEL AND PATIO PLAN Scale: 1/8" = 1'-0" 1 A1.1 N 0 8 16 FT A1.1 NOTE: SQUARE FOOTAGE CALCULATED TO INTERIOR OF WALLS FOR OCCUPANCY CALCULATION (N) 2x WALL CONSTRUCTION (E) WALL CONSTRUCTION TO REMAIN (E) CONSTRUCTION REMOVED L K J H G EF D6 C B4 A 1 .2 1 2 3 .6 3 3 .4 4 5 7 4 .2 D 6 1 .2 1 2 3 .6 3 3 .4 4 5 7 4 .2 6 M B EXISTING FENCE BUSSER SERVER HOST EXISTING TREE UP OUTDOOR PATIO (E) 46 SEATS (E) LIFT EXISTING OVERHANG (E) RESTAURANTENTRANCE (E) PLANTER BED (E) WAIT AREA (E) RESTROOM 1 (E) RESTROOM 2 (E) KITCHEN (E) DISHROOM (E) PREPKITCHEN (E) WALK-IN (E) DINING AREA (E) 79 SEATS (E) BAR (E) 15 SEATS (E) WINECOOLER (E) STO. (E) CRAWLSPACE (E) MECH ROOM (E) ELEVSHAFT (E) ELECROOM (E) CRAWLSPACE (E) COMMON AREA (E) WINE STORAGE (E) STORAGEAREA EG R E S S 4' - 3 " 4'-0 " EGR E S S EXISTING ENTRANCE TO OUTDOOR PATIO UP UP UP UP UP UP UP (E) MECH (E) ELECROOM (E) ELEC EQUIPMENT TO BE RELOCATED. PANELS TO REMAIN. (E) COVERED EXTERIORWALKWAY 3'-6 7/16" (E) TRANSFORMERS (E) FENCE (E) RETAINING WALL (E) STORAGE (E) OFFICE(E) STORAGE ANDMECH UP (E ) R A M P OUTLINE DESIGNATES BAR SERVICE AREA 1 1 1 (E) ELECTRICAL/MAINTENANCE (E) ELECTRICAL/ MAINTENANCE AREA (E) VACANT AREA FORMERLY LEASED BY 'BORDER'S BOOKS' (FORMULA RETAIL) NOTE LEGEND: 1 1 30'-1" 13 ' - 1 0 " 15 ' - 3 " 1,480 SQ FT (E) FORMER BORDER'SBOOKSTORE 2,337 SQ FT PR O P O S E D B A S E M E N T & P A T I O P L A N 1/8" =1'-0" MEJRK 50 U N I V E R S I T Y A V E N U E LO S G A T O S C A 9 5 0 3 0 AP N # : 5 2 9 - 0 2 - 0 4 4 PR O J E C T N U M B E R : V - 0 5 DRAFTED BY: THE DESIGN AND IDEAS REPRESENTED ON THIS SHEET ARE THE PROPERTY OF MARK ENGLISH ARCHITECTS. ANY UNAUTHORIZED USE WITHOUT WRITTEN PERMISSION IS PROHIBITED. COPYRIGHT MARK ENGLISH ARCHITECTS, 2013. REVISIONS: NO. DATE DESCRIPTION CLIENT APPROVALSIGNATURE: CHECKED BY: PRINT DATE: SCALE: E ma r k @ m a r k e n g l i s h a r c h i t e c t s .c o m TH E W I N E C E L L A R DISCLAIMER: ALL NEW AND EXISTING DIMENSIONS SHOWN ARE BASED ON CAD BACKGROUNDS PROVIDED BY THE CLIENT & FIELD MEASUREMENTS TAKEN BY THE ARCHITECT'S OFFICE. THE ARCHITECT DOES NOT MAKE ANY WARRANTY, EXPRESSED OR IMPLIED OR ASSUME ANY LEGAL LIABILITY OR RESPONSIBILITY FOR THE ACCURACY OR COMPLETENESS OF THE EXISTING DIMENSIONS. 07.14.2016 7/31/13 2016.07.11 PLANNING RESUBMITTAL1 PROPOSED LOWER LEVEL & PATIO PLAN Scale: 1/8" = 1'-0" 1 A2.1 N 0 8 16 FT A2.1 NOTE: SQUARE FOOTAGE CALCULATED TO INTERIOR OF WALLS FOR OCCUPANCY CALCULATION (N) 2x WALL CONSTRUCTION (E) WALL CONSTRUCTION TO REMAIN (E) CONSTRUCTION REMOVED (N) RAMP 1:12 SLOPE MAX L K J H G EF D6 C B4 A 1 .2 1 2 3 .6 3 3 .4 4 5 7 4 .2 D 6 1 .2 1 2 3 .6 3 3 .4 4 5 7 4 .2 6 M B EXISTING FENCE BUSSER SERVER HOST EXISTING TREE UP OUTDOOR PATIO (N) 58 SEATS (E) LIFT EXISTING OVERHANG (E) RESTAURANTENTRANCE (E) PLANTER BED (E) WAIT AREA (E) KITCHEN (E) DISHROOM (E) PREPKITCHEN (E) WALK-IN (E) BAR (N) 10 SEATS (E) WINECOOLER (E) STO. (E) CRAWLSPACE (E) MECH ROOM (E) ELEVSHAFT (E) ELECROOM (N) MECH (E) CRAWLSPACE (N) ELECROOM DN (E) STORAGE (N) BAR SERVICERAIL EG R E S S 4' - 3 " 4'-0 " EGR E S S EXISTING ENTRANCE TO OUTDOOR PATIO UP UP UP UP UP DN (N) RAMP 1:12 SLOPE MAX UP (N) CORRIDOR (N) RECEPTION DN (E) COVERED EXTERIORWALKWAY (N) LIFT (N) WINE LOCKERSABOVE FOOTING (E) MECH (E) MECH(N) RELOCATEDACCESS HATCH (N) SELF-CLOSING1 HR FIRE RATEDDOOR (N) WASH SINK.LOCATE EXISTINGPLUMBING (N) STORAGE,PREP, ICE, ANDBEVERAGESTATION RELOCATE ELEC EQUIPMENT (N) WAIT STATION (N) NICHES, TYP (N) DISPLAYCASE / WINESTORAGE (N) FURRED OUT WALL. MAKE FLUSH WITH ELEC PANELS (N) HOST STATION (E) STAIR RELOCATE MECHANICAL EQUIPMENT 3'-6 7/16" (E) TRANSFORMERS (E) FENCE (E) RETAINING WALL(N) OFFICE (E) MAINTENANCE &ELECTRICAL TOREMAIN 599 SQFT UP UP (E ) R A M P (N) BENCH (N) BENCH (E) RESTROOM 1 (E) RESTROOM 2 (E) DINING AREA 1 (N) 72 SEATS (N) DINING AREA 3 44 SEATS (N) COMMONAREA (N) DINING AREA 2 16 SEATS (N) RR 4(N) RR 3 (E) EXIT & STAIR (N) SERVICE STATION 24'-0" 6'-9" 4'-6 1/8" 15'-10"11'-9"11'-7 5/8"12'-5 7/16"11'-10 5/16"10'-9 1/4" 45'-11 7/8" 12 ' - 3 " 15'-0" 39 ' - 0 " 43'-8 1/4" 22 ' - 0 1 / 8 " 22 ' - 5 1 / 8 " 29'-2 1/16" 24'-5 1/8" 10 ' - 3 1 / 4 " 7'-8 7/16"12'-0 1/4"12'-4 1/8"6'-10 3/8"21'-5 13/16"8'-4" 42'-4 1/4"60'-0" 148'-4" 26 ' - 7 1 / 2 " 12 ' - 4 1 / 2 " 4' - 0 " 13 ' - 7 3 / 8 " 10 ' - 2 1 / 8 " 10 ' - 2 1 / 8 " 10 ' - 9 1 1 / 1 6 " 2' - 4 1 / 2 " 10 ' - 4 " 5' - 5 5 / 8 " 34 ' - 7 3 / 8 " 73 ' - 8 7 / 8 " 40 ' - 1 " 11 3 ' - 9 7 / 8 " (E) VACANT AREA FORMERLY LEASED BY 'BORDER'S BOOKS' (FORMULA RETAIL), 1,780 SQ FT, TO BE CONVERTED TO RESTAURANT USE OUTLINE DESIGNATES BAR SERVICE AREA 5'-3 1/2" 1 1 1 1 (E) MAINTENANCE & ELECTRICAL AREA, 881 SQ FT, TO BE CONVERTED TO RESTAURANT USE 1 TOTAL (N) TENANT SPACES 2,661 SQFT PR O P O S E D B A S E M E N T & P A T I O P L A N : OC C U P A N C Y & E G R E S S 1/8" =1'-0" MEJRK 50 U N I V E R S I T Y A V E N U E LO S G A T O S C A 9 5 0 3 0 AP N # : 5 2 9 - 0 2 - 0 4 4 PR O J E C T N U M B E R : V - 0 5 DRAFTED BY: THE DESIGN AND IDEAS REPRESENTED ON THIS SHEET ARE THE PROPERTY OF MARK ENGLISH ARCHITECTS. ANY UNAUTHORIZED USE WITHOUT WRITTEN PERMISSION IS PROHIBITED. COPYRIGHT MARK ENGLISH ARCHITECTS, 2013. REVISIONS: NO. DATE DESCRIPTION CLIENT APPROVALSIGNATURE: CHECKED BY: PRINT DATE: SCALE: E ma r k @ m a r k e n g l i s h a r c h i t e c t s .c o m TH E W I N E C E L L A R DISCLAIMER: ALL NEW AND EXISTING DIMENSIONS SHOWN ARE BASED ON CAD BACKGROUNDS PROVIDED BY THE CLIENT & FIELD MEASUREMENTS TAKEN BY THE ARCHITECT'S OFFICE. THE ARCHITECT DOES NOT MAKE ANY WARRANTY, EXPRESSED OR IMPLIED OR ASSUME ANY LEGAL LIABILITY OR RESPONSIBILITY FOR THE ACCURACY OR COMPLETENESS OF THE EXISTING DIMENSIONS. 07.14.2016 7/31/13 2016.07.11 PLANNING RESUBMITTAL1 PROPOSED LOWER LEVEL & PATIO PLAN: OCCUPANCY & EGRESS Scale: 1/8" = 1'-0" 1 A2.2 N 0 8 16 FT A2.2 NOTE: SQUARE FOOTAGE CALCULATED TO INTERIOR OF WALLS FOR OCCUPANCY CALCULATION (N) 2x WALL CONSTRUCTION (E) WALL CONSTRUCTION TO REMAIN (E) CONSTRUCTION REMOVED L K J H G EF D6 C B4 A 1 .2 1 2 3 .6 3 3 .4 4 5 7 4 .2 D 6 1 .2 1 2 3 .6 3 3 .4 4 5 7 4 .2 6 M B BUSSER SERVER HOST UP (E) OUTDOOR PATIO (N) 58 SEATS (E) LIFT EXISTING OVERHANG (E) RESTAURANTENTRANCE (E) PLANTER BED (E) WAIT AREA (E) RESTROOM 1 (E) RESTROOM 2 (E) KITCHEN (E) DISHROOM (E) PREPKITCHEN (E) WALK-IN (E) DINING AREA 1 (N) 72 SEATS (E) BAR (N) 10 SEATS (E) WINECOOLER (E) STO. (E) CRAWLSPACE (E) MECH ROOM 1 (E) ELEVSHAFT (E) ELECROOM 1 (N) MECH ROOM 2 (E) CRAWLSPACE (N) DINING AREA 3 44 SEATS (N) ELECROOM 2 (N) COMMONAREA DN (E) STORAGE (N) DINING AREA 2 16 SEATS (N) BAR SERVICERAIL EG R E S S 4' - 3 " 4'-0 " EGR E S S UP UP UP UP UP DN (N) RAMP UP (N) CORRIDOR (N) RECEPTION DN (N) RAMP (E) COVERED EXTERIORWALKWAY (N) LIFT (E) MECH (E) MECH (N) WAIT STATION (N) NICHES, TYP (N) DISPLAYCASE / WINESTORAGE (N) FURRED OUT WALL. MAKE FLUSH WITH ELEC PANELS (N) RR 4 (E) STAIRWELL 3'-6 7/16" (N) OFFICE (E) MAINTENANCE UP UP (E ) R A M P (N) RR 3 (N) HALL (N) SERVICE STATION (E) ACCESSIBLE PATH OF TRAVEL (N) ACCESSIBLE PATH OF TRAVEL EXIT TO STREETFROM LOWERLEVEL EXIT TO STREETFROM LOWERLEVEL (E) ACCESSIBLE PATH OF TRAVEL (E) ACCESSIBLE PATH OF TRAVEL EXIT TO STREET EXIT TO STREET 1 HR SEPARATION 1 HR SEPARATION 1 HR SEPARATION 1 HR SEPARATION 1 HR SEPARATION EXIT TO STREET FROM LOWER LEVEL 9'-6 9/16" 3' - 8 1 / 8 " 7' - 0 9 / 1 6 " 4'-7 3/16" 3'-6 1/4" FIXED BOOTH SEATING WITHOUT DIVIDING ARMS. TOTAL BACKREST LENGTH:13'-2"OCCUPANT LOAD: 6 4' - 4 " 9'-1 7/8" 5 - FIXED SEATING BOOTHS WITHOUT DIVIDING ARMS. TOTAL BACKREST LENGTH:11'-10"OCCUPANT LOAD PER BOOTH: 5 TOTAL OCCUPANT LOAD:25 FIXED SEATING BOOTH WITHOUT DIVIDING ARMS. TOTAL BACKREST LENGTH:13'-6"OCCUPANT LOAD: 6 9'- 8 11 / 1 6 " 4' - 3 7 / 1 6 " (E) EXIT & STAIR 3' - 3 1 / 2 " 4'-1 3/8" 9' - 0 " 5' - 1 0 3 / 1 6 " 5' - 1 0 3 / 1 6 " 4'-6" 4'-6 1/8" 4'-7 3/8" 4' - 1 " 9'-7 5/8" 8'-0" 9' - 0 " 112'-11 5/8" 69 ' - 8 7 / 8 " 79 ' - 2 1 / 2 " (E) STO. 15'-10"11'-9"11'-7 5/8"12'-5 7/16"11'-10 5/16"10'-9 1/4" 45'-11 7/8" 12 ' - 3 " 7'-8 7/16"12'-0 1/4"12'-4 1/8"12'-1 13/16"21'-5 13/16"8'-4" 42'-4 1/4"60'-0" 148'-4" 4' - 0 " 13 ' - 7 3 / 8 " 10 ' - 2 1 / 8 " 10 ' - 2 1 / 8 " 10 ' - 9 1 1 / 1 6 " 10 ' - 4 " 5' - 5 5 / 8 " 34 ' - 7 3 / 8 " 73 ' - 8 7 / 8 " 40 ' - 1 " 11 3 ' - 9 7 / 8 " 2 (N) RESTROOMS W/ 2 TOILET FIXTURES AND 1 LAVOTORY PER EACH OCCUPANCY A-2 EXISTING (E) KITCHEN (E) DINING AREA 1 (E) FIXED SEATING* (E) WINE COOLER (E) WAITING AREA (E) RESTROOM 1 (E) RESTROOM 2 (E) STORAGE (E) STAIRWELL (E) EXIT & STAIR TOTAL - EXISTING PROPOSED ADDITION (N) CORRIDOR (N) DINING AREA 2 (N) RESTROOM 3 (N) RESTROOM 4 (N) OFFICE (N) RECEPTION (N) COMMON AREA (N) ELEC ROOM 2 (N) DINING AREA 3 (N) SERVICE STATION (N) HALL TOTAL PROPOSED 200 15 - 300 15 - - 300 - - - 15 - - 100 15 15 300 15 15 - AREA SQ. FT/ PERSON TOTAL SQ. FT OCCUPANTS 538 1,207 355 52 120 48 48 310 108 142 2,928 675 585 55 55 157 141 131 35 1,178 236 39 3,287 2 80 37 0 8 - - 1 - - 126 - 39 - - 1 9 8 0 78 15 - 150 TOTAL BUILDING OCCUPANCY 276 (E) OUTDOOR PATIO 15 894 59 6,215 *OCCUPANCY FOR BOOTH FIXED SEATING DEFINED BY ICC 1004.7.