Loading...
Item 2 - Staff Report with Exhibits 1-9.15602 Benedict Lane PREPARED BY: JOCELYN SHOOPMAN Associate Planner Reviewed by: Planning Manager and Community Development Director 110 E. Main Street Los Gatos, CA 95030 ● (408) 354-6872 www.losgatosca.gov TOWN OF LOS GATOS PLANNING COMMISSION REPORT MEETING DATE: 09/28/2022 ITEM NO: 2 DATE: September 23, 2022 TO: Planning Commission FROM: Joel Paulson, Community Development Director SUBJECT: Requesting Approval for Demolition of an Existing Single-Family Residence and Construction of a New Single-Family Residence on Property Zoned R-1:8. Located at 15602 Benedict Lane. APN 424-22-008. Architecture and Site Application S-21-036. PROPERTY OWNER: Alireza Mirbagheri and Shadi Zomorrodi. APPLICANT: Azadeh Masrour. PROJECT PLANNER: Jocelyn Shoopman. RECOMMENDATION: Denial. PROJECT DATA: General Plan Designation: Low Density Residential Zoning Designation: R-1:8 (Single-Family Residential – 8,000 square-foot minimum lot size) Applicable Plans & Standards: General Plan, Residential Design Guidelines Parcel Size: 9,645 square feet Surrounding Area: Existing Land Use General Plan Zoning North Residential Low Density Residential R-1:8 South Residential Low Density Residential and Mixed Use Commercial R-1:8, C-1, and CH East Residential Mixed Use Commercial C-1 and CH West Residential Low Density Residential R-1:8 PAGE 2 OF 8 SUBJECT: 15602 Benedict Lane/S-21-036 DATE: September 23, 2022 S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Staff Report.15602 Benedict Lane.docx CEQA: The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. FINDINGS: ▪ The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. ▪ The project meets the objective standards of Chapter 29 of the Town Code (Zoning Regulations). ▪ As required for compliance with the Residential Design Guidelines. CONSIDERATIONS: ▪ As required by Section 29.20.150 of the Town Code for granting approval of an Architecture and Site application. ACTION: The decision of the Planning Commission is final unless appealed within ten days. BACKGROUND: The subject property is located on the east side of Benedict Lane (Exhibit 1). The property is approximately 9,645 square feet and is developed with an existing 1,387-square foot, single- story residence with a 620-square foot attached garage. The project is being considered by the Planning Commission due to concerns related to the project’s consistency with the Residential Design Guidelines in terms of neighborhood compatibility and the recommendations provided by the Town’s Consulting Architect. PROJECT DESCRIPTION: A. Location and Surrounding Neighborhood The subject property is located on the east side of Benedict Lane, approximately 150 feet north of Chirco Drive (Exhibit 1). The property is developed with a single-family residence and attached garage. Single-family residential development abuts the property to the north, south, and west. Commercial development abuts the property to the east. PAGE 3 OF 8 SUBJECT: 15602 Benedict Lane/S-21-036 DATE: September 23, 2022 S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Staff Report.15602 Benedict Lane.docx PROJECT DESCRIPTION (continued): B. Project Summary The applicant proposes to demolish the existing 1,387-square foot residence and construct a new 2,882-square foot, one-story single-family residence with an attached 436- square foot garage (Exhibit 9). C. Zoning Compliance A single-family residence is permitted in the R-1:8 zone. The proposed residence is in compliance with the allowable floor area, building coverage, setbacks, parking, and height requirements for the property. No exceptions are requested. DISCUSSION: A. Architecture and Site Analysis The applicant is proposing to demolish the existing one-story 1,387-square foot ranch style residence and 620-square foot attached garage. The applicant proposes the construction of a modern style one-story single-family home with 2,882 square feet of house floor area and a 436-square foot attached garage. The height of the proposed building would be approximately 17 feet where a maximum of 30 feet is allowed. The applicant has provided a Letter of J ustification summarizing the project (Exhibit 4). The proposed Development Plans are included in Exhibit 9. The proposed project materials include: smooth stucco walls; a black metal standing seam roof; a wood siding feature above the front entry; aluminum windows; and a metal trellis over the front entry and garage. The Color and Materials Board is included on Sheet A- 05.01 of Exhibit 9. B. Building Design The proposed residence would be of a modern style, with a black standing seam metal roof, smooth stucco siding, a wood siding feature above the front entry, aluminum windows, and a metal trellis over the front entry and garage (Exhibit 9). In their Letter of Justification (Exhibit 4), the applicant cites an eclectic mix of styles of homes within the immediate neighborhood, which includes ranch, contemporary, and modern styles. The applicant’s PAGE 4 OF 8 SUBJECT: 15602 Benedict Lane/S-21-036 DATE: September 23, 2022 S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Staff Report.15602 Benedict Lane.docx DISCUSSION (continued): letter details their efforts to discuss the project with their neighbors. Lastly, the letter describes the consideration given to the surrounding neighborhood in designing a project that is architecturally compatible. The Town’s Consulting Architect reviewed the proposed residence on April 8, 2022 (Exhibit 5). The Consulting Architect noted that the proposed home is designed in a traditional Eichler-like architectural style. The Consulting Architect identified several issues with the project that were inconsistent with the Residential Design Guidelines. In response, the applicant made two modifications to the design of the residence and provided written responses to the remaining issues and recommendations of the Consulting Architect (Exhibit 6). The recommendations identified by the Consulting Architect are provided below, followed by the applicant’s response in italics. 1. Lower the height of the entry and roof eaves to bring the design more into scale with its human occupants and the proposed architectural style. The garage mass measurement is 13 feet and has been designed to this height to provide a visual cover to the roof form behind it. As noted in the Consulting Architect’s report, the overall scale of the house is well within the building height of the immediate neighborhood. A metal overhang above the proposed garage was added to reduce the visual scale of the garage mass. 2. Reevaluate all window types and proportions to be consistent with the proposed architectural style. Window types and proportions were modified to be consistent with the proposed architectural style. 3. Add trim to all windows. Residential Design Guideline 3.7.4 states that wood trim is encouraged on stucco houses unless the window frames are recessed at least six inches. The proposed window design will be recessed two inches. In addition, there are several other homes in the immediate neighborhood with similar windows to the proposed design. 4. Increase all roof overhangs. The roof overhang on the left-hand side of the residence was increased to two feet; however, the other section of the roof on the right-hand side was not increased in order to ensure the overall height of the residence is not increased. PAGE 5 OF 8 SUBJECT: 15602 Benedict Lane/S-21-036 DATE: September 23, 2022 S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Staff Report.15602 Benedict Lane.docx DISCUSSION (continued): 5. Consider adding translucent windows adjacent to the entry door. The proposed floor plan has a closet behind the wall adjacent to the front door. From the interior of the residence, the space is intended as a needed closet which does not allow for a window to be added on the wall. From the outside visual, the plan is to have a large plant or something else visually to cover the blank exterior wall. 6. If additional wall materials such as stone or wood siding are proposed on the front elevation, carry those materials consistently around all sides of the house. The stone material on the rear elevation is not at the same plane of the stucco, resulting in a plane change between the two materials. In addition, the same stone material is used on both the front and rear elevation of the residence which is consistent with Residential Design Guideline 3.2.2. In addition to the recommendations identified by the Consulting Architect, two approaches for design revisions were identified to provide traditional variations to the proposed roof form to be more compatible with the immediate neighborhood and consistent with the Town’s Residential Design Guidelines. The Consulting Architect provided two approaches to a refined roof form, Approach #1, a hip roof, or Approach #2, a single gable roof, as these were consistent roof forms seen on residences within the immediate neighborhood. The applicant responded to the Consulting Architect’s recommendation to a modified roof form for the residence below: There are several homes in the greater neighborhood with styles similar to the proposed residence. Therefore, considering the greater neighborhood, the proposed plan is not different from the other homes and complies with the Residential Design Guidelines. As detailed above, the applicant has made two of the recommended modifications to the design in response to the recommendations made by the Consulting Architect and has provided justification for not making the additional recommended modifications. C. Neighborhood Compatibility The immediate neighborhood contains primarily one-story residences, with two, two-story residences. Based on Town and County records, the residences in the immediate area range in size from 1,056 square feet to 3,149 square feet. The floor area ratios (FARs) range from 0.11 to 0.31. The proposed residence would be 2,882 square feet with a FAR of 0.30. Pursuant to Town Code, the maximum allowable square footage for the 9,645-square foot PAGE 6 OF 8 SUBJECT: 15602 Benedict Lane/S-21-036 DATE: September 23, 2022 S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Staff Report.15602 Benedict Lane.docx DISCUSSION (continued): lot is 3,017 square feet with a maximum FAR of 0.31. The table below reflects the current conditions of the immediate neighborhood. Address Zoning House SF Garage SF Total SF Site SF Building FAR Stories 15624 Benedict R-1:8 3,149 720 3,869 16,515 0.19 1 15588 Benedict R-1:8 2,992 437 3,429 9,659 0.31 1 15572 Benedict R-1:8 1,056 400 1,456 9,643 0.11 1 15625 Benedict R-1:8 1,118 480 1,598 13,941 0.08 1 15603 Benedict R-1:8 1,545 320 1,865 9,375 0.16 1 15589 Benedict R-1:8 2,308 400 2,708 9,375 0.25 2 15573 Benedict R-1:8 1,154 324 1,478 9,375 0.12 1 155651 Benedict R-1:8 2,104 976 3,080 9,373 0.22 2 15602 Benedict (N) R-1:8 2,882 436 3,318 9,645 0.30 1 15602 Benedict (E) R-1:8 1,387 620 2,007 9,645 0.14 1 The proposed residence would comply with the maximum allowed floor area and height for the property and would not be the largest home in the immediate neighborhood in terms of square footage or FAR. D. Tree Impacts The Consulting Arborist reviewed the development plans, visited the property, and prepared a report for the project, noting that there are eight protected trees, adjacent to the development, with three of the eight trees being located on neighboring properties (Exhibit 7). The report recommends removal of tree #37 due to its direct conflict with the proposed footprint of the residence. No other trees on the site are proposed for removal. The Draft Conditions of Approval include a condition that all recommendations of the Town Arborist be implemented by the applicant prior to issuance of a Building Permit (Exhibit 3). E. Neighbor Outreach and Public Comments The applicant’s Letter of Justification provides a summary of their efforts to communicate with their neighbors (Exhibit 4). Story poles and project signage were installed on site by August 29, 2022. Public comments received by 11:00 a.m., Friday, September 23, 2022, are included as Exhibit 8. PAGE 7 OF 8 SUBJECT: 15602 Benedict Lane/S-21-036 DATE: September 23, 2022 S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Staff Report.15602 Benedict Lane.docx DISCUSSION (continued): F. Environmental Review The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. CONCLUSION: A. Summary The applicant is requesting approval of an Architecture and Site application for construction of a new 2,882-square foot single-family residence and a 436-square foot attached garage (Exhibit 9). The project is in compliance with the objective standards of the Town Code related to allowable floor area, height, setbacks, lot coverage, and on-site parking requirements. The project was reviewed by the Town’s Consulting Architect who provided recommendations for the project to refine the design to be more compatible with the immediate neighborhood and the Town’s Residential Design Guidelines (Exhibit 5). In response to the recommendations of the Consulting Architect, the applicant responded to two of the issues identified in the report through revision of the proposed residence and provided justification for not making the additional recommended modifications (Exhibit 6). B. Recommendation Based on the analysis above, staff recommends denial of the Architecture and Site application based on concerns related to the project’s compatibility with the immediate neighborhood and consistency with the Residential Design Guidelines, as discussed in this report. C. Alternatives Alternatively, the Commission can: 1. Approve the application by taking the following actions: a. Make the finding that the proposed project is categorically exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures (Exhibit 2); b. Make the finding that the project complies with the objective standards of Chapter 29 of the Town Code (Zoning Regulations) (Exhibit 2); c. Make the finding that the project complies with the Town’s Residential Design Guidelines (Exhibit 2); and PAGE 8 OF 8 SUBJECT: 15602 Benedict Lane/S-21-036 DATE: September 23, 2022 S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Staff Report.15602 Benedict Lane.docx CONCLUSION (continued): d. Approve Architecture and Site application S-21-036 with the conditions contained in Exhibit 3 and the development plans in Exhibit 9. 2. Approve the application with additional and/or modified conditions; or 3. Continue the matter to a date certain with specific direction. EXHIBITS: 1. Location Map 2. Required Findings and Considerations 3. Recommended Conditions of Approval 4. Letter of Justification 5. Consulting Architect Report 6. Applicant’s Response to Consulting Architect Report 7. Consulting Arborist Report 8. Public Comments received prior to 11:00 a.m., Friday, September 23, 2022 9. Development Plans LOS GATOS BLCHI R C O D R BENEDICT LNCORINNE DRLOS GATO S- A L M A D E N R D 15602 Benedict Lane 0 0.250.125 Miles ° Update Notes:- Updated 12/20/17 to link to tlg-sql12 server data (sm)- Updated 11/22/19 adding centerpoint guides, Buildings layer, and Project Site leader with label- Updated 10/8/20 to add street centerlines which can be useful in the hillside area- Updated 02-19-21 to link to TLG-SQL17 database (sm) EXHIBIT 1 This Page Intentionally Left Blank S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\ITEM 2 - 15602 BENEDICT LANE\EXHIBIT 2 - REQUIRED FINDINGS AND CONSIDERATIONS.DOCX PLANNING COMMISSION – September 28, 2022 REQUIRED FINDINGS AND CONSIDERATIONS FOR: 15602 Benedict Lane Architecture and Site Application S-21-036 Requesting Approval for Demolition of an Existing Single-Family Residence and Construction of a New Single-Family Residence on Property Zoned R-1:8. Located at 15602 Benedict Lane. APN 424-22-008. PROPERTY OWNER: Alireza Mirbagheri and Shadi Zomorrodi APPLICANT: Azadeh Masrour PROJECT PLANNER: Jocelyn Shoopman FINDINGS Required Finding for CEQA: ■ The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. Required Compliance with the Zoning Regulations: ■ The project meets the objective standards of Chapter 29 of the Town Code (Zoning Regulations). Required Compliance with the Residential Design Guidelines: ■ The project is in compliance with the Residential Design Guidelines for single - family residences not in hillside areas. CONSIDERATIONS Required Considerations in Review of Architecture and Site Applications: ■ As required by Section 29.20.150 of the Town Code, the considerations in review of an Architecture and Site application were all made in reviewing this project . EXHIBIT 2 This Page Intentionally Left Blank S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx PLANNING COMMISSION – September 28, 2022 CONDITIONS OF APPROVAL 15602 Benedict Lane Architecture and Site Application S-21-036 Requesting Approval for Demolition of an Existing Single-Family Residence and Construction of a New Single-Family Residence on Property Zoned R-1:8. Located at 15602 Benedict Lane. APN 424-22-008. PROPERTY OWNER: Alireza Mirbagheri and Shadi Zomorrodi APPLICANT: Azadeh Masrour PROJECT PLANNER: Jocelyn Shoopman TO THE SATISFACTION OF THE DIRECTOR OF COMMUNITY DEVELOPMENT: Planning Division 1. APPROVAL: This application shall be completed in accordance with all of the conditions of approval and in substantial compliance with the approved plans. Any changes or modifications to the approved plans and/or business operation shall be approved by the Community Development Director, DRC or the Planning Commission depending on the scope of the changes. 2. EXPIRATION: The approval will expire two years from the approval date pursuant to Section 29.20.320 of the Town Code, unless the approval has been vested. 3. STORY POLES: The story poles on the project site shall be removed within 30 days of approval of the Architecture & Site application. 4. OUTDOOR LIGHTING: Exterior lighting shall be kept to a minimum, and shall be down directed fixtures that will not reflect or encroach onto adjacent properties. No flood lights shall be used unless it can be demonstrated that they are needed for safety or security. 5. TREE REMOVAL PERMIT: A Tree Removal Permit shall be obtained for any trees to be removed, prior to the issuance of a building or grading permit. 6. EXISTING TREES: All existing trees shown on the plan and trees required to remain or to be planted are specific subjects of approval of this plan, and must remain on the site. 7. ARBORIST REQUIREMENTS: The developer shall implement, at their cost, all recommendations identified in the Arborist’s report for the project, on file in the Community Development Department. These recommendations must be incorporated in the building permit plans and completed prior to issuance of a building permit where applicable. 8. TREE FENCING: Protective tree fencing and other protection measures shall be placed at the drip line of existing trees prior to issuance of demolition and building permits and shall remain through all phases of construction. Include a tree protection plan with the construction plans. EXHIBIT 3 S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx 9. TREE STAKING: All newly planted trees shall be double-staked using rubber tree ties. 10. FRONT YARD LANDSCAPE: Prior to issuance of a Certificate of Occupancy the front yard must be landscaped. 11. WATER EFFICIENCY LANDSCAPE ORDINANCE: The final landscape plan shall meet the Town of Los Gatos Water Conservation Ordinance or the State Water Efficient Landscape Ordinance, whichever is more restrictive. A review fee based on the current fee schedule adopted by the Town Council is required when working landsca pe and irrigation plans are submitted for review. 12. TOWN INDEMNITY: Applicants are notified that Town Code Section 1.10.115 requires that any applicant who receives a permit or entitlement from the Town shall defend, indemnify, and hold harmless the Town and its officials in any action brought by a third party to overturn, set aside, or void the permit or entitlement. This requirement is a condition of approval of all such permits and entitlements whether or not expressly set forth in the approval, and may be secured to the satisfaction of the Town Attorney. 13. COMPLIANCE MEMORANDUM: A memorandum shall be prepared and submitted with the building plans detailing how the Conditions of Approval will be addressed. Building Division 14. PERMITS REQUIRED: A Demolition Permit is required for the demolition of the existing single-family residence and detached garage. A separate Building Permit is required for the construction of the new single-family residence and attached garage. An additional Building Permit will be required for the PV System if the system is required by the California Energy Code. 15. APPLICABLE CODES: The current codes, as amended and adopted by the Town of Los Gatos as of January 1, 2020, are the 2019 California Building Standards Code, California Code of Regulations Title 24, Parts 1-12, including locally adopted Energy Reach Codes. 16. CONDITIONS OF APPROVAL: The Conditions of Approval must be blue lined in full on the cover sheet of the construction plans. A Compliance Memorandum shall be prepared and submitted with the building permit application detailing how the Conditions of Approval will be addressed. 17. BUILDING & SUITE NUMBERS: Submit requests for new building addresses to the Building Division prior to submitting for the building permit application process. 18. SIZE OF PLANS: Minimum size 24” x 36”, maximum size 30” x 42”. 19. REQUIREMENTS FOR COMPLETE DEMOLITION OF STRUCTURE: Obtain a Building Department Demolition Application and a Bay Area Air Quality Management District Application from the Building Department Service Counter. Once the demolition form has been completed, all signatures obtained, and written verification from PG&E that all utilities have been disconnected, return the completed form to the Building Departmen t Service Counter with the Air District’s J# Certificate, PG&E verification, and three (3) sets of site plans showing all existing structures, existing utility service lines such as water, sewer, and PG&E. No demolition work shall be done without first obtaining a permit from the Town. 20. SOILS REPORT: A Soils Report, prepared to the satisfaction of the Building Official, containing foundation and retaining wall design recommendations, shall be submitted with S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx the Building Permit Application. This report shall be prepared by a licensed Civil Engineer specializing in soils mechanics. 21. SHORING: Shoring plans and calculations will be required for all excavations which exceed five (5) feet in depth, or which remove lateral support from any existing building, adja cent property, or the public right-of-way. Shoring plans and calculations shall be prepared by a California licensed engineer and shall confirm to the Cal/OSHA regulations. 22. FOUNDATION INSPECTIONS: A pad certificate prepared by a licensed civil engineer or land surveyor shall be submitted to the project Building Inspector at foundation inspection. This certificate shall certify compliance with the recommendations as specified in the Soils Report, and that the building pad elevations and on -site retaining wall locations and elevations have been prepared according to the approved plans. Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered Civil Engineer for the following items: a. Building pad elevation b. Finish floor elevation c. Foundation corner locations d. Retaining wall(s) locations and elevations 23. TITLE 24 ENERGY COMPLIANCE: All required California Title 24 Energy Compliance Forms must be blue-lined (sticky-backed), i.e., directly printed, onto a plan sheet. 24. TOWN RESIDENTIAL ACCESSIBILITY STANDARDS: New residential units shall be designed with adaptability features for single-family residences per Town Resolution 1994-61: a. Wood backing (2” x 8” minimum) shall be provided in all bathroom walls, at water closets, showers, and bathtubs, located 34 inches from the floor to the center of the backing, suitable for the installation of grab bars if needed in the future. b. All passage doors shall be at least 32-inch-wide doors on the accessible floor level. c. The primary entrance door shall be a 36-inch-wide door including a 5’x 5’ level landing, no more than 1 inch out of plane with the immediate interior floor level and with an 18-inch clearance at interior strike edge. d. A door buzzer, bell or chime shall be hard wired at primary entrance. 25. BACKWATER VALVE: The scope of this project may require the installation of a sanitary sewer backwater valve per Town Ordinance 6.50.025. Please provide information on the plans if a backwater valve is required and the location of the installation. T he Town of Los Gatos Ordinance and West Valley Sanitation District (WVSD) requires backwater valves on drainage piping serving fixtures that have flood level rims less than 12 inches above the elevation of the next upstream manhole. 26. HAZARDOUS FIRE ZONE: All projects in the Town of Los Gatos require Class A roof assemblies. 27. SPECIAL INSPECTIONS: When a special inspection is required by CBC Section 1704, the Architect or Engineer of Record shall prepare an inspection program that shall be submitted to the Building Official for approval prior to issuance of the Building Permit. The Town Special Inspection form must be completely filled-out and signed by all requested parties prior to permit issuance. Special Inspection forms are available from the Building Division Service Counter or online at www.losgatosca.gov/building. S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx 28. BLUEPRINT FOR A CLEAN BAY SHEET: The Town standard Santa Clara Valley Nonpoint Source Pollution Control Program Sheet (page size same as submitted drawings) shall be part of the plan submittal as the second page. The specification sheet is available at the Building Division Service Counter for a fee of $2 or at ARC Blueprint for a fee or online at www.losgatosca.gov/building. 29. APPROVALS REQUIRED: The project requires the following departments and agencies approval before issuing a building permit: a. Community Development – Planning Division: (408) 354-6874 b. Engineering/Parks & Public Works Department: (408) 399-5771 c. Santa Clara County Fire Department: (408) 378-4010 d. West Valley Sanitation District: (408) 378-2407 e. Local School District: The Town will forward the paperwork to the appropriate school district(s) for processing. A copy of the paid receipt is required prior to permit issuance. TO THE SATISFACTION OF THE DIRECTOR OF PARKS & PUBLIC WORKS: Engineering Division 30. GENERAL: All public improvements shall be made according to the latest adopted Town Standard Plans, Standard Specifications and Engineering Design Standards. All work shall conform to the applicable Town ordinances. The adjacent public right-of-way shall be kept clear of all job-related mud, silt, concrete, dirt and other construction debris at the end of the day. Dirt and debris shall not be washed into storm drainage facilities. The storing of goods and materials on the sidewalk and/or the street will not be allowed unless an encroachment permit is issued by the Engineering Division of the Parks and Public Works Department. The Owner and/or Applicant's representative in charge shall be at the job site during all working hours. Failure to maintain the public right-of-way according to this condition may result in the issuance of correction notices, citations, or stop work orders and the Town performing the required maintenance at the Owner and/or Applicant's expense. 31. APPROVAL: This application shall be completed in accordance with all the conditions of approval listed below and in substantial compliance with the latest reviewed and approved development plans. Any changes or modifications to the approved plans or conditions of approvals shall be approved by the Town Engineer. 32. CONSTRUCTION PLAN REQUIREMENTS: Construction drawings shall comply with Section 1 (Construction Plan Requirements) of the Town’s Engineering Design Standards, which are available for download from the Town’s website. 33. ENCROACHMENT PERMIT: All work in the public right -of-way will require a Construction Encroachment Permit. All work over $5,000 will require construction security. It is the responsibility of the Owner/Applicant to obtain any necessary encroachment permit s from affected agencies and private parties, including but not limited to, Pacific Gas and Electric (PG&E), AT&T, Comcast, Santa Clara Valley Water District, California Department of Transportation (Caltrans). Copies of any approvals or permits must be submitted to the S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx Town Engineering Division of the Parks and Public Works Department prior to releasing any permit. 34. RESTORATION OF PUBLIC IMPROVEMENTS: The Owner and/or Applicant or their representative shall repair or replace all existing improvements not d esignated for removal that are damaged or removed because of the Owner and/or Applicant or their representative's operations. Improvements such as, but not limited to: curbs, gutters, driveways, signs, pavements, raised pavement markers, thermoplastic pavement markings, etc., shall be repaired and replaced to a condition equal to or better than the original condition. Any new concrete shall be free of stamps, logos, names, graffiti, etc. Any concrete identified that is displaying a stamp or equal shall b e removed and replaced at the Contractor’s sole expense and no additional compensation shall be allowed therefore. Existing improvement to be repaired or replaced shall be at the direction of the Engineering Construction Inspector and shall comply with all Title 24 Disabled Access provisions. The restoration of all improvements identified by the Engineering Construction Inspector shall be completed before the issuance of a certificate of occupancy. The Owner and/or Applicant or their representative shall request a walk-through with the Engineering Construction Inspector before the start of construction to verify existing conditions. 35. STREET CLOSURE: Any proposed blockage or partial closure of the street requires an encroachment permit. Special provisions such as limitations on works hours, protective enclosures, or other means to facilitate public access in a safe manner may be required. 36. DRIVEWAY: The driveway conform to existing pavement on Benedict Lane shall be constructed in a manner such that the existing drainage patterns will not be obstructed. 37. PUBLIC IMPROVEMENTS: The following improvements shall be installed by the Owner and/or Applicant. Plans for those improvements shall be prepared by a California registered civil engineer, reviewed and approved by the Town before the issuance of any grading or building permits or the recordation of a map. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. 38. GENERAL LIABILITY INSURANCE: The property owner shall provide proof of insurance to the Town on a yearly basis. In addition to general coverage, the policy must cover all elements encroaching into the Town’s right-of-way. 39. PUBLIC WORKS INSPECTIONS: The Owner and/or Applicant or thei r representative shall notify the Engineering Inspector at least twenty-four (24) hours before starting any work pertaining to on-site drainage facilities, grading or paving, and all work in the Town's right- of-way. Failure to do so will result in penalties and rejection of any work that occurred without inspection. a. Benedict Lane: Rolled curb, and tie-in paving along the property frontage. b. Benedict Lane: 2” overlay from the centerline to the eastern lip of gutter, or alternative pavement restoration measure as approved by the Town Engineer. 40. SITE SUPERVISION: The General Contractor shall provide qualified supervision on the job site at all times during construction. 41. GRADING PERMIT: A grading permit is required for all site grading and drainage work except for exemptions listed in Section 12.20.015 of The Code of the Town of Los Gatos (Grading Ordinance). After the preceding Architecture and Site Application has been S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx approved by the respective deciding body, the grading permit application (with grading plans and associated required materials and plan check fees) shall be made to the Engineering Division of the Parks and Public Works Department located at 41 Miles Avenue. The grading plans shall include final grading, drainage, retaining wall location(s), driveway, utilities and interim erosion control. Grading plans shall list earthwork quantities and a table of existing and proposed impervious areas. Unless specifically allowed by the Director of Parks and Public Works, the grading permit will be issued concurrently with the building permit. The grading permit is for work outside the building footprint(s). Prior to Engineering signing off and closing out on the issued grading permit, the Owner’s soils engineer shall verify, with a stamped and signed letter, that the grading activities were completed per plans and per the requirements as noted in the soils report. A separate building permit, issued by the Building Department, located at 110 E. Main Street, is needed for grading within the building footprint . 42. DESIGN CHANGES: Any proposed changes to the approved plans shall be subject to the approval of the Town prior to the commencement of any and all altered work. The Owner and/or Applicant’s project engineer shall notify, in writing, the Town Engineer at l east seventy-two (72) hours in advance of all the proposed changes. Any approved changes shall be incorporated into the final “as-built” plans. 43. PLANS AND STUDIES: All required plans and studies shall be prepared by a Registered Professional Engineer in the State of California and submitted to the Town Engineer for review and approval. Additionally, any studies imposed by the Planning Commission or Town Council shall be funded by the Owner and/or Applicant. 44. DRAINAGE IMPROVEMENT: Prior to the issuance of any grading/improvement permits, the Owner and/or Applicant shall: a) design provisions for surface drainage; and b) design all necessary storm drain facilities extending to a satisfactory point of disposal for the proper control and disposal of storm runoff; and c) provide a recorded copy of any required easements to the Town. 45. PRECONSTRUCTION MEETING: Prior to the commencement of any site work, the general contractor shall: a. Along with the Owner and/or Applicant, attend a pre -construction meeting with the Town Engineer to discuss the project conditions of approval, working hours, site maintenance and other construction matters; b. Acknowledge in writing that they have read and understand the project conditions of approval and will make certain that all project sub-contractors have read and understand them as well prior to commencing any work, and that a copy of the project conditions of approval will be posted on-site at all times during construction. 46. SOILS REPORT: One electronic copy (PDF) of the soils and geologic report shall be submitted with the application. The soils report shall include specific criteria and standards governing site grading, drainage, pavement design, retaining wall design, and erosion control. The reports shall be signed and "wet stamped" by the engineer or geologist, in conformance with Section 6735 of the California Business and Professions Code. 47. SOIL RECOMMENDATIONS: The project shall incorporate the geotechnical/geological recommendations contained in the project’s design-level geotechnical/geological S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx investigation as prepared by the Owner and/or Applicant’s engineer(s), and any subsequently required report or addendum. Subsequent reports or addendum are subject to peer review by the Town’s consultant and costs shall be borne by the Owner and/or Applicant. 48. WATER METER: The water meter shall be relocated within the property in question, directly behind the public right-of-way line. The Owner and/or Applicant shall repair and replace to existing Town standards any portion of concrete flatwork within said right-of- way that is damaged during this activity prior to issuance of a certificate of occupancy. 49. CERTIFICATE OF OCCUPANCY: The Engineering Division of the Parks and Public Works Department will not sign off on a Temporary Certificate of Occupancy or a Final Certificate of Occupancy until all required improvements within the Town’s right-of-way have been completed and approved by the Town. 50. FRONTAGE IMPROVEMENTS: The Owner and/or Applicant shall be required to improve the project’s public frontage (right-of-way line to centerline and/or to limits per the direction of the Town Engineer) to current Town Standards. These improvements may include but not limited to curb, gutter, driveway approach(es), signs, pavement, raised pavement markers, thermoplastic pavement markings, etc. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. 51. UTILITIES: The Owner and/or Applicant shall install all new, relocated, or temporarily removed utility services, including telephone, electric power and all other communications lines underground, as required by Town Code Section 27.50.015(b). All new utility services shall be placed underground. Underground conduit shall be provided for cable television service. The Owner and/or Applicant is required to obtain approval of all proposed utility alignments from any and all utility service providers before a Certificate of Occupancy for any new building can be issued. The Town of Los Gatos does not approve or imply approval for final alignment or design of these facilities. 52. SIDEWALK IN-LIEU FEE: A sidewalk in-lieu fee of $5,544.00 shall be paid prior to issuance of a grading or building permit. This fee is based on 346.5 square feet of 4.5-foot wide sidewalk at $16.00 per square foot in accordance with Town policy and the Town’s Comprehensive Fee Schedule. The final curb and sidewalk in-lieu fee for this project shall be calculated using the current fee schedule and rate schedule in effect at the time the fee is paid. 53. ROLLED CURB REPAIR: The Owner and/or Applicant shall repair and replace to existing Town standards any rolled curb damaged now or during construction of this project. All new and existing adjacent infrastructure must meet Town standards. New curb shall be constructed per Town Standard Details. New concrete shall be free of stamps, logos, names, graffiti, etc. Any concrete identified that is displaying a stamp or equal shall be removed and replaced at the Contractor’s sole expense and no additional compensation shall be allowed therefore. The limits of curb repair will be determined by the Engineering Construction Inspector during the construction phase of the project. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx 54. FENCING: Any fencing proposed within two hundred (200) feet of an intersection shall comply with Town Code Section §23.10.080. 55. SIGHT TRIANGLE AND TRAFFIC VIEW AREA: Any proposed improvements, including but not limiting to trees and hedges, will need to abide by Town Code Sections 23.10.080, 26.10.065, and 29.40.030. 56. CONSTRUCTION VEHICLE PARKING: Construction vehicle parking within the public right-of- way will only be allowed if it does not cause access or safety problems as determined by the Town. 57. CONSTRUCTION TRAFFIC CONTROL: All construction traffic and related vehicular routes, traffic control plan, and applicable pedestrian or traffic detour plans shall be submitted for review and approval by the Town Engineer prior to the issuance of an encroachment, grading or building permit. 58. HAULING OF SOIL: Hauling of soil on- or off-site shall not occur during the morning or evening peak periods (between 7:00 a.m. and 9:00 a.m. and between 4:00 p.m. and 6:00 p.m.), and at other times as specified by the Director of Parks and Public Works. Cover all trucks hauling soil, sand and other loose debris. 59. CONSTRUCTION HOURS: All construction activities, including the delivery of construction materials, labors, heavy equipment, supplies, etc., shall be limited to the hours of 8:00 a.m. to 6:00 p.m., weekdays and 9:00 a.m. to 4:00 p.m. Saturdays, holidays excluded. The Town may authorize, on a case-by-case basis, alternate construction hours. The Owner and/or Applicant shall provide written notice twenty-four (24) hours in advance of modified construction hours. Approval of this request is at discretion of the Town. 60. CONSTRUCTION NOISE: Between the hours of 8:00 a.m. to 8:00 p.m., weekdays and 9:00 a.m. to 7:00 p.m. weekends and holidays, construction, alteration or repair activities shall be allowed. No individual piece of equipment shall produce a noise level exceeding eighty - five (85) dBA at twenty-five (25) feet from the source. If the device is located within a structure on the property, the measurement shall be made at distances as close to twenty - five (25) feet from the device as possible. The noise level at any point outside of the property plane shall not exceed eighty-five (85) dBA. 61. CONSTRUCTION MANAGEMENT PLAN SHEET: Prior to the issuance of any grading or building permits, the Owner and/or Applicant’s design consultant shall submit a construction management plan sheet (full-size) within the plan set that shall incorporate at a minimum the Project Schedule, employee parking, construction staging area, materials storage area(s), concrete washout(s) and proposed outhouse location(s). Please refer to the Town’s Construction Management Plan Guidelines document for additional information. 62. WVSD (West Valley Sanitation District): A Sanitary Sewer Clean-out is required for each property at the property line, within one foot of the property line per West Valley Sanitation District Standard Drawing 3, or at a location specified by the Town. 63. SANITARY SEWER BACKWATER VALVE: Drainage piping serving fixtures which have flood level rims less than twelve (12) inches (304.8 mm) above the elevation of the next upstream manhole and/or flushing inlet cover at the public or private sewer system serving such drainage piping shall be protected from backflow of sewage by installing an approved type backwater valve. Fixtures above such elevation shall not discharge through the S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx backwater valve, unless first approved by the Building Official. The Town shall not incur any liability or responsibility for damage resulting from a sewer overflow where the property owner or other person has failed to install a backwater valve as defined in the Uniform Plumbing Code adopted by the Town and maintain such device in a functional operation condition. Evidence of West Sanitation District’s decision on whether a backwater device is needed shall be provided prior to the issuance of a building permit. 64. BEST MANAGEMENT PRACTICES (BMPs): The Owner and/or Applicant is responsible for ensuring that all contractors are aware of all storm water quality measures and that such measures are implemented. Best Management Practices (BMPs) shall be maintained and be placed for all areas that have been graded or disturbed and for all material, equipment and/or operations that need protection. Removal of BMPs (temporary removal during construction activities) shall be replaced at the end of each working day. Failure to comply with the construction BMP will result in the issuance of correction notices, citations, or stop work orders. 65. SITE DESIGN MEASURES: All projects shall incorporate at least one of the following measures: a. Protect sensitive areas and minimize changes to the natural topography. b. Minimize impervious surface areas. c. Direct roof downspouts to vegetated areas. d. Use porous or pervious pavement surfaces on the driveway, at a minimum. e. Use landscaping to treat stormwater. 66. EROSION CONTROL: Interim and final erosion control plans shall be prepared and submitted to the Engineering Division of the Parks and Public Works Department. A maximum of two (2) weeks is allowed between clearing of an area and stabilizing/building on an area if grading is allowed during the rainy season. Interim erosion control measures, to be carried out during construction and before installation of the final landscaping, shall be included. Interim erosion control method shall include, but are not limited to: silt fences, fiber rolls (with locations and details), erosion control blankets, Town standard seeding specification, filter berms, check dams, retention basins, etc. Provide erosion control measures as needed to protect downstream water quality during winter months. The Town of Los Gatos Engineering Division of the Parks and Public Works Department and the Building Department will conduct periodic NPDES insp ections of the site throughout the recognized storm season to verify compliance with the Construction General Permit and Stormwater ordinances and regulations. 67. DUST CONTROL: Blowing dust shall be reduced by timing construction activities so that paving and building construction begin as soon as possible after completion of grading, and by landscaping disturbed soils as soon as possible. Further, water trucks shall be present and in use at the construction site. All portions of the site subject to blowing dust shall be watered as often as deemed necessary by the Town, or a minimum of three (3) times daily, or apply (non-toxic) soil stabilizers on all unpaved access roads, parking areas, and staging areas at construction sites in order to insure proper control of blowing dust for the duration of the project. Watering on public streets shall not occur. Streets shall be cleaned by street sweepers or by hand as often as deemed necessary by the Town Engineer, or at least once a day. Watering associated with on -site construction activity shall take place S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx between the hours of 8 a.m. and 5 p.m. and shall include at least one (1) late -afternoon watering to minimize the effects of blowing dust. All public streets soiled or littered due to this construction activity shall be cleaned and swept on a daily basis during the workweek to the satisfaction of the Town. Demolition or earthwork activities shall be halted when wind speeds (instantaneous gusts) exceed twenty (20) miles per hour (MPH). All trucks hauling soil, sand, or other loose debris shall be covered. 68. AIR QUALITY: To limit the project’s construction-related dust and criteria pollutant emissions, the following the Bay Area Air Quality Management District (BAAQMD)- recommended basic construction measures shall be included in the project’s grading plan, building plans, and contract specifications: a. All exposed surfaces (e.g., parking areas, staging areas, soil piles, graded areas, and unpaved access roads) shall be watered two times per day, or otherwise kept dust -free. b. All haul trucks designated for removal of excavated soil and demolition debris from site shall be staged off-site until materials are ready for immediate loading and removal from site. c. All haul trucks transporting soil, sand, debris, or other loose m aterial off-site shall be covered. d. As practicable, all haul trucks and other large construction equipment shall be staged in areas away from the adjacent residential homes. e. All visible mud or dirt track-out onto adjacent public roads shall be removed using wet power vacuum street sweepers at least once per day, or as deemed appropriate by Town Engineer. The use of dry power sweeping is prohibited. An on-site track-out control device is also recommended to minimize mud and dirt-track-out onto adjacent public roads. f. All vehicle speeds on unpaved surfaces shall be limited to fifteen (15) miles per hour. g. All driveways and sidewalks to be paved shall be completed as soon as possible. Building pads shall be laid as soon as possible after grading unless seeding or soil binders are used. h. Post a publicly visible sign with the telephone number and person to contact at the lead agency regarding dust complaints. This person shall respond and take corrective action within forty-eight (48) hours. The Air District’s phone number shall also be visible to ensure compliance with applicable regulations. Please provide the BAAQMD’s complaint number on the sign: 24-hour toll-free hotline at 1-800-334-ODOR (6367). i. All excavation, grading, and/or demolition activities shall be suspended when average wind speeds exceed twenty (20) miles per hour. j. Vegetative ground cover (e.g., fast-germinating native grass seed) shall be planted in disturbed areas as soon as possible and watered appropriately until vegetation is established. 69. DETAILING OF STORMWATER MANAGEMENT FACILITIES: Prior to the issuance of any grading or building permits, all pertinent details of any and all proposed stormwater management facilities, including, but not limited to, ditches, swales, pipes, bubble -ups, dry wells, outfalls, infiltration trenches, detention basins and energy dissipaters, shall be provided on submitted plans, reviewed by the Engineering Division of the Parks and Public Works Department, and approved for implementation. S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx 70. CONSTRUCTION ACTIVITIES: All construction shall conform to the latest requirements of the CASQA Stormwater Best Management Practices Handbooks for Construction Activities and New Development and Redevelopment, the Town's grading and erosion control ordinance, and other generally accepted engineering practices for erosion control as required by the Town Engineer when undertaking construction activities. 71. SITE DRAINAGE: Rainwater leaders shall be discharged to splash blocks. No through curb drains will be allowed. On-site drainage systems for all projects shall include one of the alternatives included in section C.3.i of the Municipal Regional NPDES Permit. These include storm water reuse via cisterns or rain barrels, directing runoff from impervious surfaces to vegetated areas and use of permeable surfaces. No improvements shall obstruct or divert runoff to the detriment of an adjacent, downstream or down slope property. http://www.scvurppp-w2k.com/nd_wp.shtml?zoom_highlight=BIOTREATMENT+SOIL. 72. SILT AND MUD IN PUBLIC RIGHT-OF-WAY: It is the responsibility of Contractor and homeowner to make sure that all dirt tracked into the public right-of-way is cleaned up on a daily basis. Mud, silt, concrete and other construction debris SHALL NOT be washed into the Town’s storm drains. 73. GOOD HOUSEKEEPING: Good housekeeping practices shall be observed at all times during the course of construction. All construction shall be diligently supervised by a person or persons authorized to do so at all times during working hours. The Owner and/or Applicant's representative in charge shall be at the job site during all working hours. Failure to maintain the public right-of-way according to this condition may result in penalties and/or the Town performing the required maintenance at the Owner and/or Applicant's expense. 74. COVERED TRUCKS: All trucks transporting materials to and from the site shall be covered. TO THE SATISFACTION OF THE SANTA CLARA COUNTY FIRE DEPARTMENT: 75. GENERAL: Review of this Developmental proposal is limited to acceptability of site access, water supply and may include specific additional requirements as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work, the applicant shall make application to, and receive from, the Building Department all applicable construction permits. 76. FIRE SPRINKLERS REQUIRED: (As noted on Sheet A-00.01) An automatic residential fire sprinkler system shall be installed in all new one- and two-family dwellings as follows. 77. REQUIRED FIRE FLOW: The fire flow for this project is 500 GPM at 20 psi residual pressure since an automatic fire sprinkler system will be installed. Note: The minimum required number and spacing of the hydrants shall be in accordance with CFC Table C102.1. Provide a fire flow letter from a local water purveyor (San Jose Water) confirming the required fire flow of 500 GPM @ 20 psi residual from a fire hydrant located within 600' of the farthest exterior corner of the structure. Letter shall be submitted before or with the building permit plan set. S:\PLANNING COMMISSION REPORTS\2022\09-28-2022\Item 2 - 15602 Benedict Lane\Exhibit 3 - Recommended Conditions of Approval.docx 78. WATER SUPPLY REQUIREMENTS: Potable water supplies shall be protected from contamination caused by fire protection water supplies. It is the responsibility of the applicant and any contractors and subcontractors to contact the water purveyor supplying the site of such project, and to comply with the requirements of that purveyor. Such requirements shall be incorporated into the design of any water-based fire protection systems, and/or fire suppression water supply systems or storage containers that may be physically connected in any manner to an appliance capable of causing contamination of the potable water supply of the purveyor of record. Final approval of the system(s) under consideration will not be granted by this office until compliance with the requirements of the water purveyor of record are documented by that purveyor as having been met by the applicant(s). 2019 CFC Sec. 903.3.5 and Health and Safety Code 13114.7. 79. ADDRESS IDENTIFICATION: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Where required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall be a minimum of 4 inches (101.6 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address numbers shall be maintained. CFC Sec. 505.1. 80. CONSTRUCTION SITE FIRE SAFETY: All construction sites must comply with applicable provisions of the CFC Chapter 33 and our Standard Detail and Specification S1-7. Provide appropriate notations on subsequent plan submittals, as appropriate to the project. CFC Chp. 33. 81. GENERAL: This review shall not be construed to be an approval of a violation of the provisions of the California Fire Code or of other laws or regulations of the jurisdictio n. A permit presuming to give authority to violate or cancel the provisions of the fire code or other such laws or regulations shall not be valid. Any addition to or alteration of approved construction documents shall be approved in advance [CFC, Ch.1, 1 05.3.6]. This Page Intentionally Left Blank April 8, 2022 Ms. Jocelyn Shoopman Community Development Department Town of Los Gatos 110 E. Main Street Los Gatos, CA 95031 RE: 15602 Benedict Lane Dear Jocelyn: I reviewed the drawings and evaluated the site context. My comments and recommendations are as follows: NEIGHBORHOOD CONTEXT The site is located in an established neighborhood of traditional Ranch Style homes. Houses are all one-story in height with one home having a substantially set back second story. Photos of the site and its surrounding neighborhood are shown on the following page. EXHIBIT 5 15602 Benedict Lane Design Review Comments April 8, 2022 Page 2 THE SITE House immediately across Benedict Lane Home to the immediate right Nearby home to the left on Benedict Lane Home to the immediate left Nearby home across Benedict Lane Nearby home to the left on Benedict Lane Nearby home across Benedict Lane 15602 Benedict Lane Design Review Comments April 8, 2022 Page 3 PROPOSED DESIGN The proposed home is designed in a traditional Eichler-like architectural style - see proposed elevations below. Proposed Front Elevation Proposed Left Side Elevation Proposed Rear Elevation Proposed Right Side Elevation Proposed Streetscape 15602 Benedict Lane Design Review Comments April 8, 2022 Page 4 ISSUES AND CONCERNS The proposed one-story house would be consistent with the scale and overall building height of the immediate neighborhood - see comparative streetscale illustrations below. There are, however, several issues worthy of further design discussion. 1. The proposed architectural style is heavily influenced by and is a somewhat stripped down version of a typical low-sloped roof Eichler Home of the 1960s. Normally one sees issues with new homes blending into an older Eichler neigborhood rather than designing an Eichler-like home for a traditional Ranch Style neighborhood with a preponderance of hip roofs. The proposed house design would not be consistent with Residential Design Guideline 3.2.1 3.2.1 Select an architectural style with sensitivity to the surrounding neighborhood • Avoid selecting an architectural style which typically has roof pitches that are substantially different from others in the nearby neighborhood. The proposed design in this neighborhood is also not consistent with the General Design Principles set forth in the Residential Design Guidelines. GENERAL DESIGN PRINCIPLES The following principles have been used in the development of these guidelines, and will be used by the Town to evaluate plans and designs that are not covered by a specific design guideline. • Encourage a diversity of architectural styles consistent with the neighborhood context • Design to blend into the neighborhood rather than stand out • Utilize roof forms and pitches similar to those in the immediate neighborhood 15602 Benedict Lane Design Review Comments April 8, 2022 Page 5 2. The front elevation is quite monumental in scale for the proposed architectural style. The recesssed entry is approximately 11’-6” in height with an entry door of over 9 feet, and the flat-roofed garage is almost 14 feet in height . 3. Stone and wood siding is proposed on the front elevation without carrying those materials consistently around to all other elevations which is not consistent with Residential Design Guideline 3.2.2. 3.2.2 Design for architectural integrity • Carry wall materials, window types and architectural details around all sides of the house. Avoid side and rear elevations that are markedly different from the front elevation. 4. Windows and doors without trim are not consistent with Residential Design Guideline 3.7.4. 3.7.4 Design the windows with attention to matching the traditional details of the architectural style • Most architectural styles - except Mission, Spanish Eclectic or Modern - should have wood trim around the windows. The trim width should be matched to the style, but in general, should not be less than 3 1/2 inches wide. • Wood trim is also encouraged on stucco houses unless the window frames are recessed at least 6 inches from the outside face of the wall. The use of stucco covered foam trim is strongly discouraged. 5. The roof overhangs are rather small for the proposed architectural style - see photo example below. 15602 Benedict Lane Design Review Comments April 8, 2022 Page 6 6. The change of materials in the same plane on the rear elevation would not be consistent with Residential Design Guideline 3.8.4. 3.8.4 Materials changes • Make materials and color changes at inside corners rather than outside corners to avoid a pasted on look. 7. The windows styles and proportions lack consistency which is not consistent with Residential Design Guideline 3.7.2. 3.7.2 Match window types and proportions to the architectural style and to the surrounding neighborhood • Select window types to complement the style of the house. Each architectural style generally has one or two window types that are traditional to the style. Double hung windows, for example, are common features of Victorian and Craftsman Styles while casement windows are seen frequently in Mission and Spanish Eclectic styles. • Most architectural styles feature windows that have either vertical or square proportions. Avoid horizontal window proportions unless the style (e.g., Modern or Ranch Style) is clearly supportive of that shape. Horizontal groupings of vertical and square windows are one means of providing visual balance to a facade design. • Limit the number of different window types and proportions to enhance the visual unity of the house design. 15602 Benedict Lane Design Review Comments April 8, 2022 Page 7 RECOMMENDATIONS Staff should work with the applicant to refine the design to be more compatible with the immediate neigh- borhood and the Town’s Residential Design Guidelines. There are some traditional variations to the proposed Eichler-like design that I believe would be more compatible with the immediate neighborhood and more con- sistent with the Town’s Residential Design Guidelines. Two illustrations and photo examples of similar homes are shown below. TRADITIONAL GABLE and HIP ROOFS HIP ROOF SINGLE GABLE ROOF 15602 Benedict Lane Design Review Comments April 8, 2022 Page 8 In preparing revised designs for the house, the applicant should address the following which are identified as being issues with the current design and likely to be noted again in the future unless addressed in the revised application. 1. Lower the height of the entry and roof eaves to bring the design more into scale with its human occu- pants and the proposed architectural style. 2. Reevaluate all window types and proportions to be consistent with the proposed architectural style. 3. Add trim to all windows. 4. Increase all roof overhangs. 5. Consider adding translucent windows adjacent to the entry door. 6. If additional wall materials such as stone or wood siding are proposed on the front elevation, carry those materials consistently around all sides of the house. If you would like to discuss this further, I am available at your convenience. Sincerely, CANNON DESIGN GROUP Larry L. Cannon SINGLE WIDE GABLE ROOFS September 12, 2022 Subject: 15602 Benedict Ln Los Gatos, CA 95032 PRE21-01290 Property Owners: Alireza Mirbagheri & Shadi Zomorrodi Architect: Azadeh Masrour (AMS design LLP) To: Ms. Jocelyn Shoopman Community Development Department Town of Los Gatos 110 E. Main Street Los Gatos, CA 95031 Hello, This is to provide a response to the Consulting Architecture Report dated April 8, 2022 signed by Larry L. Cannon from Cannon Design Group regarding the project referenced above. Several items were identified by the consulting architect to be addressed, and our response for each item can be found in the following pages. Can you please review our responses and provide your feedback? We’d be glad to provide any additional information that might be needed. Best Regards, Alireza Mirbagheri (Property Owner) Shadi Zomorrodi (Property Owner) EXHIBIT 6 1. Lower the height of the entry and roof eaves to bring the design more into scale with its human occupants and the proposed architectural style. Consulting Architect’s Comments: The front elevation is quite monumental in scale for the proposed architectural style. The recessed entry is approximately 11’-6” in height with an entry door of over 9 feet, and the flat- roofed garage is almost 14 feet in height. Response: The garage mass actual measurement is approximately 13 feet (and not 14 feet as noted in the report). It has been designed to this height in order to visually cover the roof behind it. As the consulting architect has also mentioned in their report, the overall scale of the house is well within building height of the immediate neighborhood. To further assist with visuals and the consulting architect’s concern, we will plan to add a minimalistic and cosmetics metal overhang in that garage mass space, which should help with the overall look of the garage mass not standing out as too large. 2. Reevaluate all window types and proportions to be consistent with the proposed architectural style. Consulting Architect’s Comments: The windows styles and proportions lack consistency which is not consistent with Residential Design Guideline 3.7.2. Response: These recommendations were reflected in the new plans submitted. 3. Add trim to all windows Consulting Architect’s Comments: Windows and doors without trim are not consistent with Residential Design Guideline 3.7.4. Response: Per residential design guideline 3.7.4, window trims are encouraged on stucco houses unless the window frames are recessed. Since our windows design will be recessed, additional trims will not be added. We currently plan to have a maximum of two inches of recess on the windows. It’s also worth mentioning that there are several other homes in the neighborhood with very similar windows to our planned design (frameless and with recess much smaller than six inches). Pictures of some of these examples can be found below: Nearby home on a street behind Benedict Ln (104 Oak Park Dr) Nearby home on a street behind Benedict Ln (221 Oak Wood Way) 4. Increase all roof overhangs Consulting Architect’s Comments: The roof overhangs are rather small for the proposed architectural style. Response: Per consulting architect’s recommendation, we will increase the roof overhang on the left side of the house. The other section of the roof to the right will not be changed in order to ensure the overall height of the house is not increased (addressing the other concern of the architect regarding the overall height of the house to match the immediate neighborhood homes). 5. Consider adding translucent windows adjacent to the entry door Consulting Architect’s Comments: Consider adding translucent windows adjacent to the entry door. Response: Per current plans, there is a closet behind the wall next to the entry door. From inside of the house, this space in the closet is needed, which doesn’t allow adding a window on this wall. From the outside, our plan is to have something in front of this wall adjacent to the entry door to cover the empty space of this wall (such as a large plant, etc.). Therefore, having a window on this wall won’t be planned to be implemented at this time. 6. If additional wall materials such as stone or wood siding are proposed on the front elevation, carry those materials consistently around all sides of the house. Consulting Architect’s Comments: Stone and wood siding is proposed on the front elevation without carrying those materials consistently around to all other elevations which is not consistent with Residential Design Guideline 3.2.2. The change of materials in the same plan on the rear elevation would not be consistent with Residential Design Guidelines 3.8.4. Response: The highlighted material above is not at the same plane as the stucco, and there is a level change between the two. Further, the same stone material is used both in the front and back of the house, which is consistent with the residential design guidelines. Additional Recommendations Consulting Architect’s Comments: Staff should work with the applicant to refine the design to be more compatible with the immediate neighborhood and the Town’s Residential Design guidelines. There are some traditional variations to the proposed Eichler-like design that I believe would be more compatible with the immediate neighborhood and more consistent with the Town’s Residential Design Guidelines. Two illustrations and photo examples of similar homes are shown below. Response: There are several homes in the neighborhood with styles similar to our proposed plan. A few examples of these homes are shown below. These examples include references to similar styles, windows without trims and small roof overhangs. Therefore, considering the big picture of this neighborhood, we don’t believe our proposed plan is radically different from other homes in the neighborhood or violates any of the residential design guidelines. In addition, we have paid close attention to our proposed design, to ensure it fits well within the immediate neighborhood. Our proposed minimalistic contemporary style provides a nice transition between the two adjacent homes to us, and blends well within the neighborhood. We have also reached out to every one of our neighbors within the immediate neighborhood (and even beyond) to inform them about our proposed plan, and they all have supported this proposal and believe that the design fits well with the neighborhood. Additional details about neighborhood outreach can be found in the last section of this letter. Nearby home on a street behind Benedict Ln (104 Oak Park Dr) Nearby home on a street behind Benedict Ln (221 Oak Wood Way) Nearby home on a street behind Benedict Ln (30 Roberts Rd) Nearby home on a street behind Benedict Ln (15621 Flintridge Dr) Neighborhood Outreach Efforts We have reached out to every one of our neighbors within the immediate neighborhood (and even beyond) to inform them about our proposed plan for the construction. We have provided print outs of our plans and handed to them. The outreach effort also included having some of our neighbors over at our house and walking them through the installed story poles, so that they can picture very clearly how the proposed plan will look like. As a result of this outreach, we were pleased to find out that all the neighbors that we spoke to are fully supportive of our plans. They in fact believe that not only the proposed plan will blend very well with the immediate neighborhood, but it’ll also help to improve the neighborhood overall. Some of these neighbors that we have spoken to in detail include the following (but not limited to this list): 1. Tammy and Robert Gore at 2. Don and Jennifer at 3. Mark and Alyssa at 4. Mohammad and Elaheh at 5. Troy and Jubi at Revision History:  April 26, 2022: initial draft submitted  September 12, 2022: - Comment#1 (Page2): specified the material for the added cosmetic overhang to be metal - Comment#3 (Page3) regarding the window trims: added more details for the plan (recess windows), with additional supporting examples from the neighborhood - Additional recommendations section (Pages 6-8): modified with supporting pictures, map and explanations - Neighborhood outreach efforts (Page 9): added section (did not exist in the first draft) - Revision history (Page 10): added this section for tracking changes easier if compared to old letter ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 1 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Assessment of Eight (8) Protected-Size Trees At and Adjacent to 15602 Benedict Lane Los Gatos, California Prepared for: Ms. Jocelyn Shoopman, Associate Planner Town of Los Gatos Community Development Department 110 E. Main Street Los Gatos, CA 95030 Field Visit: Walter Levison, Contract Town Arborist (CTA) 2/1/2022 Report by CTA 2/7/2022 EXHIBIT 7 ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 2 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Table of Contents 1.0 Summary ___________________________________________________________________________ 3 2.0 Assignment & Background _____________________________________________________________ 8 3.0 Town of Los Gatos – What Trees are Protected? ____________________________________________ 9 4.0 Recommendations ___________________________________________________________________ 11 5.0 Tree Protection and Maintenance Directions per Town Code _________________________________ 19 6.0 Tree Replacement Standards – Los Gatos Town Code ______________________________________ 22 7.0 Author’s Qualifications ________________________________________________________________ 25 8.0 Assumptions and Limiting Conditions ____________________________________________________ 26 9.0 Certification ________________________________________________________________________ 27 10.0 Digital Images _____________________________________________________________________ 28 11.0 Tree Data Table ____________________________________________________________________ 34 12.0 Tree Location & Protection Fence Map Mark-up __________________________________________ 40 13.0 Attached: CTA Tree Appraisal Worksheet per 10th Edition Guide for Plant Appraisal ______________ 40 ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 3 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 1.0 Summary a. Below is a matrix style overview of protected-size trees (non-exempt species, 4-inches diameter at 4.5 feet above grade). In the table, the CTA (Contract Town Arborist) has outlined expected impacts to each tree, along with suggestions for adjustments to the plan set (if applicable) that will optimize tree survival over the long term. Mitigation replacement rate and size is noted for each tree in the case that removal or damage to trees occurs. Note: Only trees within relatively close proximity of proposed work are included in this tree study (e.g. tree trunks located between approximately zero and 30 linear feet of current proposed new grading, utility trenching, excavation, haul routes, landscaping, etc. as shown on proposed plans, and trees with canopy driplines that encroach over the subject property lot line. Adjacent to this site (15602 Benedict Lane), there are various “exempt” trees such as privet specimens along the south boundary area, on neighbor property, near to survey trees #34 and #35, that were appropriately excluded from this CTA tree study. Similarly, there are a large number of fern pine (Podocarpus gracilior) specimens located along the west edge of the neighbor property, with canopies that slightly encroach into the 15602 Benedict site project area, which were also excluded from the study, given that they were small diameter trees in the +/- 3” to 4” diameter trunk class (not verified, not accessible), growing east of the property line wooden fence, assumedly with irrigation, arranged in a dense hedge formation on private property in an area that is not accessible for close inspection. New Staff Protocols 2021 Onward / High Risk Trees & Extreme Risk Trees & Dead Trees Per my communications with Town Planning Division Staff in 2021, all trees with a TRAQ risk rating of “high” or “extreme”, and all trees in “dead” (i.e. 0 to 5% overall condition ratings) are allowed to be removed as no-fee remov als, without any canopy replacement fees or plantings required, when a site is undergoing entitlement review. The reference for this no-fee/no-replacement removal standard is tree ordinance section 29.10.0985. Table 1.0(a) (REFER TO THE CTA’S TREE MAP MARKUP WHEN REVIEWING THIS MATRIX) Note that this property at 15602 Benedict Lane is slightly under 10,000 square feet, and has the option to mitigate per the “single family residence option” by using smaller mitigation tree plantings of 15 gallon size, rather than the standard 24” box size. Line Number Tree Tag Number Common Name Large Protected Tree (LPT)? Appraised Value Site plan changes or restrictions required to reduce impacts to “less than significant” Replacement Rate Per Canopy Lost Replacement Size Tree 1 31 Coast live oak No $1,490. No changes necessary if fencing is erected along edge of proposed new driveway footprint. 3 15 gallon or 24” box 2 32 Coast live oak No $520. No changes necessary if fencing is erected along edge of proposed new driveway footprint. 3 15 gallon or 24” box ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 4 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Line Number Tree Tag Number Common Name Large Protected Tree (LPT)? Appraised Value Site plan changes or restrictions required to reduce impacts to “less than significant” Replacement Rate Per Canopy Lost Replacement Size Tree 3 33 Deodar cedar No $32,200. No changes necessary if fencing is erected along edge of proposed new driveway footprint. 6 24” box 4 34 Coast live oak No $40. This is actually a “tall stump” due to severe topping pruning that was performed to essentially remove the entire tree down to a stump of 9 feet elevation, which then grew slightly to a height of 14 feet. No changes necessary to plans, if fencing erected along edge of proposed new driveway footprint. 2 15 gallon or 24” box 5 35 Coast live oak No $3,630. No changes necessary to plans, if fencing erected along edge of proposed new driveway footprint. The proposed new driveway will encroach to just outside of the tree’s “critical root zone” calculated at 6 x trunk diameter as a horizontal offset radius where no activity should theoretically occur, to maintain tree stability. 3 15 gallon or 24” box ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 5 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Line Number Tree Tag Number Common Name Large Protected Tree (LPT)? Appraised Value Site plan changes or restrictions required to reduce impacts to “less than significant” Replacement Rate Per Canopy Lost Replacement Size Tree 6 36 Coast live oak No $5,100. Critical root zone is 6 x diameter, which is 6 x 17” = 8.5 feet as an absolute no activity zone for stability preservation for the tree. Health preservation requires usually 1.5 x the CRZ distance (approximately). This means that the proposed residence footprint at 6 feet from trunk edge is well inside the CRZ distance, violating the minimum recommended offset distance for construction. Also note that because the exterior work rewuires a construction buffer area of at least 4 or 5 horizontal feet around the edge of the proposed new residence, the actual distance of fencing from trunk edge is going to be ~2 feet offset from trunk edge, which will further negatively impact the tree’s root system unless a soil protection buffer of geotextile and wood chips is piled up over the ground to further protect against foot traffic related soil compaction and/or machinery related soil compaction of the tree root zone. The CTA suggests pushing the residence to at least a total of 14 feet north offset from trunk edge so that fencing can be erected at 9 feet north of tree. 4 15 gallon or 24” box 7 37 Pyracantha (shrub) No $330. (Tree to be removed due to direct conflict with proposed residence footprint). Note that the applicant does not show replacement plantings in their submittal set of plans. It will be up to Staff whether the site project will be required to mitigate using on-site plantings (three trees), or will be allowed to pay in-lieu fees to some extent. 3 15 gallon or 24” box ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 6 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Line Number Tree Tag Number Common Name Large Protected Tree (LPT)? Appraised Value Site plan changes or restrictions required to reduce impacts to “less than significant” Replacement Rate Per Canopy Lost Replacement Size Tree 8 38 Coast live oak Yes $17,300. ROOF: Per the applicant’s plans, the south (rear) elevation of the sloping roof will peak at 15’8”, and slope down northward to 10’-0”. Given that roofers will need at least 5 feet of additional head clearance to install the roof, this therefore effectively requires a “working height” of ~15 feet at the north end, and 21 feet elevation at the southwest portion of the tree #38 canopy. The CTA shot elevations of the tree #38 canopy using a hypsometer and found its elevations to be roughly between 12 feet and 17 feet in height above grade, with presence of a 6 inch diameter limb that extends westward over the proposed roof footprint. The entire 6 inch diameter limb extending westward over the proposed roof will need to be removed at its attachment point at 7 feet above grade on the tree #38 mainstem, to clear the roof and roofer activity. This is acceptable, and is not expected to have a significant negative effect on the tree’s long term health or structure. CRITICAL ROOT ZONE VS. RESIDENCE FOUNDATION WORK: The critical root zone of tree #38 is 6 x 30” = 15 feet. The distance from trunk edge to new foundation of residence is roughly 12 feet, which means the encroachment will be 3 feet into the CRZ no-dig area. This is still OK, given that the tree’s north, south, and east root zone quadrants will essentially remain as open soil intact. However, it will mean that the applicant will be required to install a SOIL PROTECTION BUFFER between the RPZ chain link fencing and the new residence foundation, to prevent unnecessary soil compaction. See the CTA’s tree map for this graphic. 10 24” box ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 7 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 2017 Town of Los Gatos In-lieu fee equivalent = $250 per each required 24” box mitigation tree planting not installed on the site. (This project is on a lot that is slightly less than 10,000 square feet, and is allowed to use 15 gallon size trees for on-site replacement plantings. However, the value of each of those (smaller) mitigation plantings in terms of dollar value equivalency, is still $250 per tree). 1.0 (b) Summary of tree disposition and tree issues, based on the set of (revised) plans submitted to planning division in 2021: 1. TREE IMPACTS / “MODERATE TO SEVERE” EXPECTED: Trees #36 and #38 may experience moderate to severe negative impacts from proposed work, if the site plan is built out as currently shown on the applicant’s plan set submitted to planning division. To mitigate or offset some of the root loss associated with the current plan, the CTA suggests (assuming that both trees #36 and #38 are to be preserved): • Pushing the proposed new residence to 14 feet north of the trunk edge of tree #36, such that fencing can be erected at 9 feet north of trunk edge. • Installing a soil protection buffer between the tree #38 protection fence and the proposed new residence foundation edge, per the green highlighted strip shown on the CTA’s tree map markup below at the end of this report. Also note that this tree will require some pruning to clear the roof and roofer activity. The limb required to be removed is a 6 inch diameter limb extending westward over the proposed roof footprint. The impact of this removal will be minor to moderate only. All pruning work will have to conform to the most current ANSI-A300 pruning standards, and either be performed by, or supervised directly (full-time supervision) by an ISA Certified Arborist. 2. TREE IMPACTS / “MINOR” EXPECTED: Trees #31, 32, 33, 34, and #38 are expected to remain with little or no negative impact from proposed new site plan construction work, if fencing is erected along the south edge of the proposed driveway footprint as indicated on the CTA’s tree map markup as a heavy red dashed line. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 8 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 3. TREE REMOVALS vs. REQUIRED MITIGATION / APPLICANT: Value: The applicant is proposing to remove tree #37 (actually a shrub). The value of this tree in terms of Los Gatos canopy replacement requirement per planning division is installation of three (3) 15 gallon or 24” box size plantings on site with heavy irrigation, which is equivalent to $250 X 3 = $750, per the standard $250 valuation of a single tree planting installed at site. Location: Given that the applicant does not have a landscape plan or an irrigation plan, it is assumed that they have not yet determined a location for this tree installation of three (3) 15 gallon or 24” box size trees. Combo Mitigation: Planning Staff can either require the applicant to install three trees on site, or have the applicant pay a combination of in-lieu fees plus install on-site mitigation tree plantings. Mitigation Planting Species: Typical trees used for mitigation plantings include such pest and disease resistant trees as ‘Columbia’ plane tree, ‘Roberts’ sycamore, coast live oak, Chinese pistache, Swan Hill fruitless olive, wilson’s fruitless upright olive, silver linden (Tilia tomentosa), blue Atlas cedar, and deodar cedar. 4. SECURITY BONDING: The new 2015 iteration of the Town tree ordinance section 29.10.1000 (c)3 includes wordage that requires that all trees being retained on a development site need to be appraised for dollar value at the applicant’s expense prior to building or grading permits being issued by the Town. Part ‘f’ of this same tree ordinance section states that the Town may condition a security bond prior to issuance of a permit, in the sum of $5,000 per each tree being preserved, or $25,000, whichever is less. In the case of this site, with six trees being retained ($30,000), the minimum $25,000 bond amount would kick in as the bond amount. 2.0 Assignment & Background Walter Levison, Contract Town Arborist (CTA) was directed to tag and assess all Protected-Size (4 inch diameter and greater) trees in relatively close proximity to the proposed site plan project. The trees were tagged with numeric tags “31” through “38”, affixed to the mainstem of each tree at roughly eye-level. These tag numbers are noted on the CTA’s tree map markup attached to the end of this written report. The CTA summarized the tree situation from a long-term site manager’s perspective, both in table form and in written form above, in section 1.0. Specific recommendations for tree maintenance and protection are outlined below in section 4.0. Digital images of the trees archived by the CTA are included below in this report for reference of existing pre-project conditions. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 9 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved The tree data table with detailed tree information based on the CTA’s field assessment on 2/1/2022 makes up section 11.0 of this report. The CTA used a forester’s D-tape to determine trunk diameter at 4.5 feet above grade, or at a narrow point below a mainstem fork if the fork occurs at 4.5 feet above grade. The D-tape converts actual trunk circumference into diameter in inches and tenths of inches. Tree heights were measured using a digital Nikon forestry pro 550 hypsometer. Tree canopy spread was visually estimated. The attached tree map mark-up prepared by the CTA was created using the applicant’s site plan sheet A-00.01 dated September, 2021, marked up with various highlight coloration1 as discussed in section 12.0. The CTA reviewed the applicant’s revised set of plan sheets from September, 2021. 3.0 Town of Los Gatos – What Trees are Protected? Per the most recent (2015) iteration of the Town of Los Gatos tree ordinance (Town Code Chapter 29 – Zoning Regulations, Article 1), the following regulations apply to all trees within the Town’s jurisdiction (wordage adjusted): 1. All trees with at least a single mainstem measuring four (4) inches diameter or greater at 4.5 feet above grade are considered “Protected Trees” when removal relates to any development review. 2. 12 inch diameter (18 inch multistem total) trees on developed residential property not currently subject to development review. 3. 8 inch diameter (8 inch multistem total) blue oak (Quercus douglasii), black oak (Quercus kellogii), California buckeye (Aesculus californica), and Pacific madrone (Arbutus menziesii) on developed residential lots not currently subject to development review. 4. 8 inch diameter (8 inch multistem total) trees on developed residential property not currently subject to development review, on lots in the designated Hillside Area per the official Town map. 5. All trees with a single mainstem or sum of multiple mainstems totaling 48 inches diameter or greater at 4.5 feet above grade are considered “Large Protected Trees” (LPT). 6. All oak species (Quercus spp.), California buckeye (Aesculus californica), and Pacific madrone (Arbutus menziesii) with one or more mainstems totaling 24 inches diameter or more at 4.5 feet above grade are considered “Large Protected Trees” (LPT). 7. Section 29.10.0965. Prohibitions: A permit is required to prune, trim, cut off, or perform any work, on a single occasion or cumulatively, over a three- year period, affecting 25% or more of any Protected Tree (including below ground root system). 8. Section 29.10.0965. Prohibitions: A permit is required to prune, trim, or cut any branch or root greater than four (4) inches in diameter of a Large Protected Tree. 1 Adobe Pro was used to mark up the tree map. In order to “lock” the mark-ups, the CTA printed a PDF of the marked-up PDF sheet, which resulted on some loss of color intensity. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 10 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 9. Section 29.10.0965. Prohibitions: A permit is required to conduct severe pruning on any protected tree. Severe pruning is defined in section 29.10.0955 as “topping or removal of foliage or significant scaffold limbs or large diameter branches so as to cause permanent damage and/or disfigurement of a tree, and/or which does not meet specific pruning goals and objectives as set forth in the current version of the International Society of Arboriculture Best Management Practices-Tree Pruning and ANSI A300-Part 1 Tree, Shrub, and Other Woody Plant Management-Standard Practices, (Pruning).” 10. Exceptions: Severe Pruning Exception in Town Code section 29.10.1010(3) “…..except for pollarding of fruitless mulberry (Morus alba) or other species approved by the Town Arborist….”. Protected Tree Exceptions: a. Edible fruit or nut bearing trees less than 18 inches diameter (multistem total or single stem) b. Acacia melanoxylon (blackwood acacia) less than 24 inches (multistem total or single stem) c. Liriodendron tulipifera (tulip tree) less than 24 inches (multistem total or single stem) d. Ailanthus altissima (tree of heaven) less than 24 inches (multistem total or single stem) e. Eucalyptus globulus (Tasmanian blue gum) less than 24 inches (multistem total or single stem) f. Eucalyptus camaldulensis (River red gum) less than 24 inches (multistem total or single stem) g. Other eucalyptus species (E. spp.) not noted above, less than 24 inches (multistem total or single stem) (REMOVAL O.K. ONLY AT HILLSIDE AREA LOCATIONS PER OFFICIAL TOWN MAP): www.losgatosca.gov/documentcenter/view/176 h. All palm species (except Phoenix canariensis) less than 24 inches (multistem total or single stem) i. Ligustrum lucidum (glossy privet) less than 24 inches (multistem total or single stem) Note that per the exception in part ‘a’ above, fruiting olive trees with stems totaling less than 18 inches are considered non- protected. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 11 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 4.0 Recommendations 1. Project Arborist (“PA”): Initial Signoff It is suggested that a third party ASCA registered consulting arborist or ISA Certified Arborist with good experience with tree protection during construction be retained by the applicant, to provide pre-project verification that tree protection and maintenance measures outlined in this section of the arborist report are adhered to. Periodic (e.g. monthly) inspections and summary reporting, if required as a project condition of approval, are suggested in order to verify contractor compliance with tree protection throughout the site plan project. This person will be referred to as the project arborist (“PA”). The PA should monitor soil moisture within the root protection zones of trees being retained, using a Lincoln soil moisture probe/meter or equivalent. If required, inspection reports shall be sent to Ms. Jocelyn Shoopman, Associate Planner, at rshoopman@losgatosca.gov. Sample wordage for a condition of approval regarding monitoring of tree protection and tree condition: “The required protective fencing shall remain in place until final landscaping and inspection of the project. Project arborist approval must be obtained and documented in a monthly site activity report sent to the Town. A mandatory Monthly Tree Activity Report shall be sent at least once monthly to the Town planner associated with this project (rshoopman@losgatosca.gov ) beginning with the initial tree protection verification approval letter”. The PA is suggested to work with the project team to directly monitor a portion of the following items such as: a. Foundation work directly north of oak #36. b. Foundation work directly west of oak #38. 2. Project Team Pre-Project Clarifications or Changes Requested: i. Residence Foundation / South Side of Residence: The current proposed applicant plan shows the new residence foundation at 6 feet north of trunk edge of tree #36: a distance that is inside the critical root zone (CRZ) of the tree, calculated at 8.5 fee radius offset. The CTA suggests that Staff consider requiring the applicant to push the new residence foundation to 14 feet north of trunk edge of oak #36, (if this tree is to be retained), in order that TPZ chain link fencing can be erected at 9 feet north of trunk edge, thereby bringing the fenced off root zone area to just north of the calculated critical root zone offset distance from trunk edge. This will also allow for creation of a 5-foot wide construction corridor between the TPZ fence and the new foundation where construction personnel can walk and perform work without being blocked or hindered by the fencing. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 12 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved ii. Removal Mitigation Fees vs. On-Site Plantings: Locations: Verify with the applicant the location(s) of the required on-site mitigation trees. Species: Typical trees used for mitigation plantings include such pest and disease resistant trees as ‘Columbia’ plane tree, ‘Roberts’ sycamore, coast live oak, Chinese pistache, Swan Hill fruitless olive, wilson’s fruitless upright olive, silver linden (Tilia tomentosa), blue Atlas cedar, and deodar cedar. Irrigation: Verify irrigation type (should be high flow, with two (2) ½” diameter flood bubblers each emitting a minimum of 1.0 gallon per minute. Removal fee for tree #37 is $750, or installation of three (3) 15 gallon or 24” box size trees on site, or a combination of plantings and fees to be determined by Town Planning Staff. 3. Security Bond: It is suggested that Town Staff condition this project on receiving security bond monetary funds from the applicant in the amount of $25,000, as a hedge against potential decline or death of one or more of the survey trees to remaining on-site or off-site in close proximity to the proposed site plan project. Staff may choose to reduce this fee to a lesser amount. See table 1.0(a) for individual tree appraised values. 4. Trunk Buffer Wrap Type III Protection: Prior to demolition commencement, install a trunk buffer around the lowermost 8 to 10 feet of the mainstems of trees #31, 32, 34, 35, 36, 38. Wrap approximately 10 to 15 wraps of orange plastic snow fencing around the trunk between grade and 8 feet above grade to create a padding at least 1 to 2 inches thickness. Each tree will require at least one (1) entire roll of orange plastic snow fencing wrap. Stand 2x4 wood boards upright, side by side, around the entire circumference of the trunk. Affix using duct tape (do not use wires or ropes). See spec image at right. 5. Chain Link Fencing Type I and/or Type II Root Protection Zone (RPZ): Prior to commencing site demolition, erect chain link fencing panels set on moveable concrete block footings. Wire the fence panels to iron layout stakes pounded 24 inches into the ground at the ends of each fence panel to keep the fence route stabilized and in its correct position. Do not wire t he fence panels to the trunks of the trees. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 13 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Pre-construction fence: Per the red dashed lines on the tree map mark-up in the CTA’s arborist report (routes may be subject to change, depending on the finalized alignments of work items). Protection shall be at the farthest possible offset distances from trees #31, 32, 33, 34, 35, 36, 38. This fencing must be erected prior to any heavy machinery traffic or construction material arrival on site. The protective fencing must not be temporarily moved during construction. No materials, tools, excavated soil, liquids, substances, etc. are to be placed or dumped, even temporarily, inside the root protection zone or “RPZ”. No storage, staging, work, or other activities will be allowed inside the RPZ except with PA monitoring. Note however that some RPZ fencing areas may need to be removed or moved to allow for final landscape plant and irrigation system installation to occur. 6. Signage: The RPZ fencing shall have one sign affixed with UV-stabilized zip ties to the chain link at eye level for every 15 linear feet of fencing, minimum 8”X11” size each, plastic laminated, with wordage that includes the Town Code section that refers to tree fence protection requirements (wordage can be adjusted): TREE PROTECTION ZONE FENCE ZONA DE PROTECCION PARA ARBOLES -NO ENTRE SIN PERMISO- -LLAME EL ARBOLISTA- REMOVAL OF THIS FENCE IS SUBJECT TO PENALTY ACCORDING TO LOS GATOS TOWN CODE 29.10.1025 PROJECT ARBORIST: TELEFONO CELL: EMAIL : ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 14 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved NOTE: THE CTA IS NOT THE “PROJECT ARBORIST”. The project arborist is a private arborist contracted by the applicant or applicant’s team of professionals who then monitors the project and reports to Town of Los Gatos planning division on a monthly basis with tree condition and tree protection inspection reports. 7. Water Spray: Spray off foliage of all trees within 20 feet of construction activity using a very high power garden hose or a pressure washer system set on low pressure to wash both the upper and lower surfaces of foliage. This helps keep the gas portals (stomata) unclogged for better gas exchange which is crucial for normal tree function. Spray should be applied approximately once-monthly, or when ambient airborne dust concentration is unusually high. 8. TREE MAINTENANCE / REQUIRED: 8.1. Retain an ISA certified arborist to perform or directly supervise pruning per the following specifications and per all of the most current ANSI A300 pruning standards: 8.1.1 TREE #31 PRUNING: Raise the canopy of oak #31 to 14 feet to provide minimum vehicle airspace clearance. 8.1.2 TREE #32 PRUNING: Raise the canopy of oak #32 to 14 feet to provide minimum vehicle airspace clearance. 8.1.3 TREE #36 PRUNING: Remove branches and limbs to 2 inches diameter each on the north side of the oak #36 canopy, in order to clear vertical airspace to the proposed 15’8” finish roof elevation (this recommendation may not be needed, if the residence is pushed to 14 feet north of the trunk edge per the CTA’s suggestion). 8.1.4 TREE #36 ROOT CROWN EXCAVATION: Remove irrigation equipment, remove ivy, and remove soil, between zero (0) and 20 feet from the trunk edge of oak #36. See diagram at right for reference of correct hand-tool root crown excavation (RCX) finish height of soil in relation to buttress roots/root crown. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 15 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 8.1.5 TREE #38 PRUNING: Remove one (1) 6 inch diameter limb that extends westward into the proposed finish roof area. Remove the limb at its attachment point on the main trunk at approximately 7 feet elevation above grade. 8.1.5 TREE #38 SOIL PROTECTION BUFFER: Install a soil protection buffer between the oak #38 TPZ chain link fence and the new proposed residence foundation (i.e. between 7 feet and 12 feet west of the trunk edge of oak #38). See reference images below and right, showing various soil protection buffers on the CTA’s past projects. The minimum protection required is a layer of 6” to 12” thickness of coarse tree chipper truck type wood chips, laid down over a geotextile that is pinned down on bare soil (see image above right). The standard heavy duty soil protection buffer is a layer of 12” thickness of wood chips, overlaid with full sheets of heavy duty exterior grade plywood strapped together using steel screw plates (see image at right). Either the minimum spec or the standard heavy duty spec type of buffer is acceptable for this project. 9. Maintenance of Trees / Optional: The CTA suggests that the applicant consider optional installation of arborist cable systems and/or arborist through-bolt threaded brace rods in oak #38, as additional support systems for the tree’s structure, given that there are multiple bark inclusion type forks at 5 to 8 feet elevation that reduce the tree’s structure stability. These types of support systems need to be installed by a qualified tree care company using the ANSI A300 standards for cable diameters, brace rod diameters, etc., to ensure the systems perform as they are supposed to. Note that tree support systems such as cables, brace rods, and support posts are often false security, and may only work to slow down a failure of a tree limb or section of the tree. They cannot be considered full proof in terms of reducing risk of tree part failure and impact with persons or property. They should be considered risk reduction measures that have an unknown actual mitigation effect. Right: sample of brace rod installation locations in a tree with a bark inclusion type narrow angle fork. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 16 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 10. Temporary Irrigation During Construction: If and when directed to do so by the project arborist (PA), provide native coast live oak trees being retained on site with temporary periodic heavy irrigation during the construction period. Note that coast live oaks are dry summer regime adapted trees, and should only be irrigated on a construction site at the rate of 1x/month, at a distance as far as possible offset from the trunk (e.g. 20 feet from trunk). Water application can be made using one or more of the following methods (see sample images): • Soaker hoses. • Emitter lines. • Garden hoses. • Fire truck hoses. • Water trucks. • Tow-behind spray tank apparatus (see image at right). • On-site water tank with gravity feed. • Over-grade PVC piping with spray heads wired to rebar or other steel stakes (see image at right). 11. New Plantings / Tree Installation Specs: Ideally, two (2) high flow type adjustable bubblers each emitting 1.0 to 2 gallons per minute (2GPM), depending on percolation rate of planting pit, are set directly over the rootball of each single tree planting, and each tree is installed with two (2) wooden planting stakes (not the shipping stake), with a set of figure-8 Cinch Ties ™. The diagram below illustrates correct form for a 24” box size tree planting pit and berm construction, per arboriculture Best Management Practices. The CTA marked up the original open-source diagram from Urban Tree Foundation (2014) to add the correct location for the ½” diameter flood bubblers and flex tubes set directly over the rootball. Make sure to completely remove the shipping stake that is initially tied tightly against the trunk of each tree by the grower/nursery. This stake is only for transport, and cannot be left tied against the trunk. It must be completely removed from the trunk area in order to avoid causing damage to the tree trunk as it grows in girth. The tree stakes are cut to just above the elevation of the Cinch-Ties to avoid abrasion between the stakes and the limbs and trunk during wind movement. A watering berm consisting of site soil is formed around the edge of the rootball to force irrigation water to pool up directly over the rootball. The berm should be approximately 4 to 6 inches in height, and 8 to 12 inches in width, set directly over the rootball edge (see spec diagram below). ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 17 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved The spec image at right shows the rootball being set at 25% above surrounding finish grade elevation of the soil. This is for “poorly drained” soil situations where flooding of the planting pit may occur. Given that a large percentage of the south bay and peninsula planting sites contain clay based construction pad type soil that is very slow draining, this “poorly drained soil” specification should actually be considered the norm for most planting sites encountered in the Bay Area. At a very minimum, the rootball should be two to three inches raised above surrounding grade to encourage proper drainage away from the top of ball. Also note that the spec image below shows the correct “shallow bowl” type of planting pit dig, where the pit is at least 3X to 4X the width of the tree rootball, (and only approximately 3/4X) the rootball depth, which means that the bottom of the rootball will be sitting securely on solid, non- decompacted parent soil, without threat of being destabilized or sinking down into a previously- dug pit depth deeper than the rootball depth. The purpose of this type of “shallow bowl” pit dig is to stabilize the rootball and prevent it from sinking, while also encouraging fast growth of lateral woody roots radiating outward from the rootball into the surrounding soil outside of the pit. A second image is provided by the CTA, which is a planting and irrigation spec developed for the author’s private practice, indicating correct irrigation of a 24” box size tree over time in terms of volume, frequency, berm location, etc. for optimal growth development of the tree. This is the newest iteration of the planting specification, which now shows a recommended subdrain/root channel which is augered into the ground using a 12 inch diameter auger bore, for a distance of 5 feet depth below the bottom elevation of the planting pit: ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 18 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 19 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved RIGHT: Proper installation of a new 24” box size tree with two (2) high flow type 1.0 GPM to 2.0 GPM (gallon-per- minute) flood bubblers seen inside a steeply-sloped watering berm built using site soil. The berm is built up directly over the rootball edge, which forces irrigation water directly downward into the rootball via gravity. 12. Temporary Irrigation During Construction (If Any): To be determined by the project arborist (PA), which is not the CTA. 5.0 Tree Protection and Maintenance Directions per Town Code The following is excerpted directly from the 2015 iteration of the Town of Los Gatos tree ordinance sections which provide specific tree protection directions and limitations on root pruning and above- ground pruning: Sec. 29.10.1000. New property development. (a) A tree survey shall be conducted prior to submittal of any dev elopm ent application proposing the removal of or impact to one or m ore protected trees. T he development applicati on shall inc lude a T ree Survey Plan and Tree Preservation Report based on this surv ey. T he tree surv ey inventory numbers shall correspond to a numbered m etal tag placed on each tree on site during the tree surv ey. The tree surv ey plan shall be prepared by a certified or consulting arborist, and shall include the followi ng inf orm ation: (1) Location of all exi sting trees on the property as described in section 29.10.0995; (2) Identify all trees that could potentiall y be aff ect ed by the project (directl y or indirectly- immediately or in long term), such as upsl ope grading or com paction out side of the dripline; (3) Notation of all trees classified as protected trees; (4) In addition, for trees f our (4) inches in diam eter or larger, the plan shall specif y the precise location of the trunk and crown spread, and the species, si ze (diam eter, height , crown spread) and condition of the tree. (b) T he tree surv ey plan shall be reviewed by the T own’s consulting arborist who shall, after m aking a field visit to the propert y, indicat e in writing or as shown on approv ed plans, which trees are recommended f or preserv ation (based on a retention rating of high/moderate/low) using, as a minim um, the Standards of Review set f orth in section 29.10.0990. This plan shall be m ade part of the staff report to the Town reviewing body upon its consi deration of the application f or new property development; ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 20 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved (c) W hen developm ent impacts are wi thin the dri pline of or wi ll affect any protect ed tree, the applicant shall provide a tree preserv ation report prepared by a certified or consulting arborist. The report, based on the findings of the tree surv ey plan and other relevant inf ormation, shall be used to determine the health and structure of exi sting trees, the eff ect s of the proposed dev elopm ent and v egetation removal upon the trees, recommendations f or specific precautions necessary f or their preserv ation duri ng all phases of development (dem olition, grading, during construction, landscaping); and shall also indicat e which trees are proposed f or rem oval. T he tree preservation report shall stipulat e a required tree protection zone (TPZ) for trees to be retained, including street trees, protected trees and trees whose canopies are hanging over the projec t site f rom adjacent properties. T he T PZ shall be f enced as specified in section 29.10.1005: (1) T he final approv ed tree preservation report shall be included in the building permit set of development plans and printed on a sheet titled: T ree Preservation Instructi ons (Sheet T -1). Sheet T-1 shall be ref erenced on all relevant sheets (civil, dem olition, uti lity, landscape, irrigation) where tree im pacts from improvem ents m ay be shown to occur; (2) T he T own rev iewing body through its site and design plan review shall endeav or to protect all trees recommended f or preservation by the Town’s consulting arborist. The Town reviewing body m ay determine if any of the trees recomm ended for preserv ation should be rem oved, if based upon the evidence submitt ed the reviewing body determines that due to special site grading or other unusual characteristics associated wi th the property, the preserv ation of the tree(s) would significantly preclude feasible development of the propert y as described in section 29.10.0990; (3) Approv al of final site or landscape plans by the appropriat e T own rev iewi ng body shall comply wit h the foll owi ng requirem ent s and conditions of approv al: a. T he applicant shall, wi thin ninety (90) days of final approv al or prior to issuance of a grading or building permit, whichev er oc curs first, secure an appraisal of the condition and v alue of all trees inc luded in the tree report affected by the dev elopm ent that are required to rem ain within the development using the T ree Value Standard m ethodology as set f orth in this Chapter. The appraisal of each tree shall recognize the location of the tree in the proposed dev elopment. The appraisal shall be performed in accordance wi th the current edition of the Guide f or Plant Apprai sal published by the Council of T ree and Landscape Appraisers (CT LA) and the Species and Group Classification Guide published by the W estern Chapter of the International Societ y of Arboriculture. T he appraisal shall be perf ormed at the applicant's expense, and the appraisal shall be subject to the Director's approv al. b. T he site or landscape plans shall indicate which trees are to be rem oved. However, the plans do not constitute approval to rem ove a tree until a separate permit is granted. T he property owner or applicant shall obtain a protected tree remov al permit, as outlined in section 29.10.0980, f or each tree to be rem ov ed to satisf y the purpose of this divisi on. (d) Prior to acceptance of proposed dev elopm ent or subdivision im provements, the developer shall submit to the Director a final tree preserv ation report prepared by a certified or consulting arborist. This report shall consider all trees that wer e to remain wit hin the dev elopm ent . T he report shall note the trees' health in relation to the ini tiall y reported condition of the trees and shall note any changes in the trees' num bers or physical conditions. T he applicant wi ll then be responsi ble f or the loss of any tree not previously approved f or removal. For protected trees, which were rem ov ed, the dev eloper shall pa y a penalty in the am ount of the appraised v alue of such tree in addition to replacem ent requirements contained in section 29.10.0985 of this Code. T he applicant shall remain responsible f or the health and survival of all trees wi thin the development for a period of five (5) years f oll owi ng acceptance of the public im provem ent s of the dev elopment or certificat e of occupancy. (e) Prior to issuance of any dem olition, gr ading or building permit, the applicant or contractor shall submit to the Buil ding Departm ent a written statem ent and photographs v erif ying that the required tree protection f ence is installed around street trees and protected trees in accordance with the tree preservation report. (f) If required by the Director and conditioned as part of a di scretionary approval, a security guarantee shall be prov ided to the T own. Prior to the ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 21 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved issuance of any permit all owing construction to begin, the applicant shall post cash, bond or other security satisf actory to the Director , in the penal sum of five thousand dollars ($5,000.00) f or each tree required to be preserv ed, or twenty-fiv e thousand dollars ($25,000.00), whichever is less. T he cash, bond or other security shall be retained f or a period of one (1) year f oll owing acceptanc e of the public improvements f or the developm ent and shall be forfeited in an am ount equal to fiv e thousand dollars ($5,000.00) per tree as a civil penalt y in the ev ent that a tree or trees required to be preserv ed are rem ov ed, destroyed or severel y damaged. (g) An applicant wit h a proposed dev elopment which requires underground utilities shall av oid the inst allation of said utilities wit hin the dripline of existing trees whenev er possi ble. In the ev ent that this is unav oidable, all trenching shall be done using directional bori ng, air-spade excavation or by hand, taking extrem e caution to avoid dam age to the root structure. W ork within the dripline of existing trees shall be supervised at all times by a certified or consulting arborist. (h) It shall be a violation of thi s division f or any propert y owner or agent of the owner to fail to com ply with any development approval condition concerning preserv ation, protec tion, and m aintenance of any protected tree. (Ord. No. 2114, §§ I, II, 8-4-03) Sec. 29.10.1005. Protection of trees during construction. (a) Protectiv e tree f encing shall specif y the f ollowing: (1) Size and m aterials. Six (6) f oot high chain link fencing, m ounted on two-inch diameter galv anized iron posts, shall be driven into the ground to a depth of at least two (2) f eet at no m or e than 10-f oot spacing. For paving area that will not be dem olished and wh en stipulated in a tree preserv ation plan, posts m ay be supported by a concrete base. (2) Area t ype to be f enced. T ype I: Enclosure with chain link fencing of either the entire dripline area or at the tree protection zone (TPZ), when spec ified by a certified or consulting arborist. Type II: Enclosure f or street trees located in a planter strip: chain link fence around the entire planter strip to the outer branches. Type III: Protection for a tree located in a sm all planter cutout only (such as downtown): orange plast ic f encing shall be wrapped around the trunk from the ground to the first branch with 2-inc h wooden boards bound securely on the outside. Caution shall be used to avoid dam aging any bark or branches. (3) Duration of Type I, II, III f encing. Fencing shall be erected bef ore dem olition, grading or construction permits are issued and rem ain in place until the wor k is com pleted. Contractor shall first obtain the approval of the project arborist on record prior to rem oving a tree protection f ence. (4) W arning sign. Each tree fence shall have prominentl y displayed an 8.5 x 11-inch sign stating: "W arning—T ree Protection Zone-this f ence shall not be rem oved and is subject to penalt y according to Town Code 29.10.1025". (b) All persons, shall com ply with the f ollowing precautions: (1) Prior to the commencem ent of construction, inst all the f ence at the dri pline, or tree protection zone (TPZ ) when specified in an approv ed arborist report, around any tree and/or v egetation to be retained which could be affected by the construction and prohibit any storage of construction materials or other m aterial s, equipment cleaning, or parking of vehicles wi thin the TPZ. T he dripline shall not be altered in any way so as to increase the encroachment of the construction. (2) Prohibit all construction activities within the TPZ, including but not limited to: excavation, grading, drainage and lev eling wi thin the dripline of the tree unless approv ed by the Director. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 22 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved (3) Prohibit disposal or deposi ting of oil, gasoline, chemicals or other harmf ul m aterials wit hin the dripline of or in drainage channels, swales or areas that m ay lead to the dri pline of a protected tree. (4) Prohibit the attachm ent of wires, signs or ropes to any pr otected tree. (5) Design utility services and irrigation lines to be located outsi de of the dripline when f easi ble. (6) Retain the serv ices of a certified or consulting arborist who shall serv e as the project arborist for periodic monitoring of the project site and the health of those trees to be preserved. T he project arborist shall be present whe never activities occur which m ay pose a potential threat to the health of the trees to be pr eserved and shall docum ent all site visits. (7) T he Di rect or and project arborist shall be notified of any dam age that occurs to a protected tree during construction so that proper treatment m ay be admini stered. (Ord. No. 2114, §§ I, II, 8-4-03) Sec. 29.10.1010. Pruning and maintenance. All pruning shall be in accordance with the current version of the International Societ y of Arboriculture Best Managem ent Practices—T ree Pruning and ANSI A300-Part 1 T ree, Shrub and Other W oody Plant Managem ent—St andard Practices, (Pruning) and any special conditions as determined by the Director. For developments, which require a tree preservati on report, a certif ied or consulting arborist shall be in reasonable charge of al l activities involving protected trees, incl uding pruning, cabling and any other work if specified. (1) Any public utility installing or m aintaining any overhead wires or underground pi pes or conduits in the vicinity of a protect ed tree shall obtai n permission from the Director before performing any work, including pruning, which m ay cause injury to a protected tree. (e.g. cable TV/fiber optic trenching, gas, water, sewer trench, etc.). (2) Pruning f or clearance of uti lity lines and energized conductors shall be perf ormed in com pliance wit h the current versi on of the American National Standards Institute (ANSI) A300 (Part 1)- Pruning, Section 5.9 Utility Pruning. Using spikes or gaffs when pruning, ex cept where no other alternative is available, is prohibited. (3) No person shall prune, trim, cut of f, or perf orm any work, on a singl e occasion or cum ulativel y, over a three-year period, aff ecting twenty-five percent or m ore of the crown of any protected tree without first obtaining a permit pur suant to this division ex cept f or pollarding of fruitless mulberry trees (Morus alba) or other species approv ed by the T own Arborist. Applications f or a pruning permit shall include photographs indi cating where pruning is proposed. (4) No person shall rem ove any Heritage tree or large protected tree branch or root through pruning or other m ethod greater than four (4) inches in diameter (12.5” in circumference) wit hout first obtaining a permit pursuant to this division. (Ord. No. 2114, §§ I, II, 8-4-03) 6.0 Tree Replacement Standards – Los Gatos Town Code (Excerpted from Town Code 29.10.0985 and 29.10.0987) (1) T wo (2) or m or e replacement trees, of a species and size desi gnated by the Director, shall be planted on the subject privat e property. T able 3-1 T he T ree Canopy—Replacem ent Standard shall be used as a basis for this requirem ent . The person requesti ng the perm it shall pay the cost of purchasing and planting the replacement trees. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 23 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved (2) If a tree or trees cannot be reasonabl y plant ed on the subject property, an in-lieu paym ent in an am ount set f ort h by the T own Council by resolution shall be pai d to the Town Tree Replacement Fund to: a. Add or replace trees on public propert y in the vicini ty of the subject propert y; or b. Add or replac e trees or landscaping on ot her T own propert y; or c. Support the Town’s urban f orestry managem ent program. (Ord. No. 2114, §§ I, II, 8-4-03) T abl e 3-1 - T ree Canopy - Replacem ent Standard Canopy Size of Removed Tree 1 (Staff is using 24” box size as the Replacement Standard for SFR Projects as of 2016) 2,4 Single Family Residential Replacement3,4 10 feet or less Two 24 inch box trees Two 15 gal lon trees More than 10 feet to 25 f eet Three 24 inch box trees Three 15 gallon trees More than 25 feet to 40 feet Four 24 inch box trees; or Two 36 inch box trees Four 15 gal lon trees More than 40 feet to 55 f eet Six 24 inch box trees; or Three 36 inch box trees Not Available Greater than 55 feet Ten 24 inc h box trees; or Five 36 inch box trees Not Available Notes 1T o m easure an asymm etri cal canopy of a tree, the widest m easurem ent shall be used to determine canopy size. 2Of ten, it is not possible to replace a single large, older tree wit h an equivalent tree(s). In this case, the tree m ay be replaced wit h a com bination of both the T ree Canopy Replacem ent Standard and in-lieu payment in an am ount set f ort h by T own Council resolution paid to the T own T ree Replacem ent Fund. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 24 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 3Single Famil y Residential Replacement Option is av ailable f or developed single f amily resi dential lot s under 10,000 square f eet that are not subject to the Town’s Hillside Developm ent Standards and Guidelines. Al l 15-gallon trees m ust be planted on-site. Any in-lieu fees for singl e f amily residential shall be based on 24” box tree rates as adopted by Town Council. 4Replacement Trees shall be approved by the T own Arborist and shall be of a species suited to the available planting location, proximity to structures, ov erhead clearances, soil type, com patibilit y with surrounding canopy and other relevant f actor s. Replacem ent wit h native species shall be strongl y encouraged. Replacem ent requirements in the Hillsides shall com ply wi th the Hillside Developm ent Standards and Guidelines Appendix A and Section 29.10.0987 Special Provisions--Hillsides. Sec. 29.10.0987. Special Provisions—Hillsides T he T own of Los Gatos recognizes its hillsides as an im portant natural resource and sensi tive habitat which is also a key com ponent of the T own’s identity, character and charm . In order to maintain and encourage restoration of the hill si de env ironm ent to its natural state, the Town has established the f oll owing special provisions f or tree rem oval and replacement in the hillsides: (1) All protected trees locat ed 30 or m or e f eet from the prim ary residence that are rem oved shall be replaced with native trees listed in Appendix A Recommended Native Trees for Hillside Areas of the Town of Los Gatos Hillside Development Standards and Guidelines (HDS&G). (2) All protected trees located wit hin 30 f eet of the primary residence that are remov ed shall be replaced as f ollows: (a) If the rem oved tree is a native tree listed in Appendix A of the HDS&G, it shall onl y be replaced wit h a native tree listed in Appendix A of the HDS&G. (b) If the rem oved tree is not listed in Appendix A, i t m ay be replaced wit h a tree listed in Appendix A, or replaced with another species of tree as approved by the Director. (c) Replacem ent trees list ed in Appendix A m ay be planted anywhere on the property. (d) Replacement trees not listed in Appendix A m ay only be planted withi n 30 f eet of the primary residence. (3) Replacem ent requirem ents shall com ply wit h the requirem ents in T abl e 3-1 Tree Canopy Replacement Standard of thi s Code. (4) Propert y owner s should be encouraged to ret ain dead or declining trees where they do not pose a safety or fire hazard, in order to foster wi ldlife habitat and the natural renewal of the hillside environment. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 25 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 7.0 Author’s Qualifications • Continued education through The American Society of Consulting Arborists, The International Society of Arboriculture (Western Chapter), and various governmental and non-governmental entities. • Contract Town Arborist, Town of Los Gatos, California Community Development Department / Planning Division 2015-present • Tree Risk Assessment Qualified (ISA TRAQ Course Graduate, Palo Alto, California) • Millbrae Community Preservation Commission (Tree Board) 2001-2006 • ASCA Registered Consulting Arborist #401 • ASCA Arboriculture Consulting Academy graduate, class of 2000 • Associate Consulting Arborist Barrie D. Coate and Associates 4/99-8/99 • Contract City Arborist, City of Belmont, California Planning and Community Development Department 5/1999-5/2020 (21 years) • ISA Certified Arborist #WC-3172 • Peace Corps Soil and Water Conservation Extension Agent Chiangmai Province, Thailand 1991-1993 • B.A. Environmental Studies/Soil and Water Resources UC Santa Cruz, Santa Cruz, California 1990 UCSC Chancellor’s Award, 1990 (My full curriculum vitae is available upon request) ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 26 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 8.0 Assumptions and Limiting Conditions Any legal description provided to the consultant/appraiser is assumed to be correct. Any titles and ownership to any property are assumed to be good and marketable. No responsibility is assumed for matters legal in character. Any and all property is appraised and evaluated as through free and clean, under responsible ownership and competent management. It is assumed that any property is not in violation of any applicable codes, ordinance, statutes, or other government regulations. Care has been taken to obtain all information from reliable sources. All data has been verified insofar as possible; however, the consultant/appraiser can neither guarantee nor be responsible for the accuracy of information provided by others. The consultant/appraiser shall not be required to give testimony or to attend court by reason of this report unless subsequen t contractual arrangements are made, including paym ent of an additional fee for such services as described in the fee schedule and contract of engagement. Unless required by law otherwise, the possession of this report or a copy thereof does not imply right of publication or use for any other purpose by any other than the person to whom it is addressed, without the prior expressed written or verbal consent of the consultant/appraiser. Unless required by law otherwise, neither all nor any part of the contents of this report, nor copy thereof, shall be conveyed by anyone, including the client, to the public through advertising, public relations, news, sales, or other media, without the prior expressed conclusions, identity of the consultant/appraiser, or any reference to any professional society or institute or to any initiated designation conferred upon the consultant/appraiser as stated in his qualifications. This report and any values expressed herein represent the opinion of the consultant/appraiser, and the consultant’s/appraiser’s fee is in no way contingent upon the reporting of a specified value, a stipulated result, the occurrence of a subsequent event, nor upon any finding to be reported. Sketches, drawings, and photographs in this report, being intended for visual aids, are not necessarily to scal e and should not be construed as engineering or architectural reports or surveys unless expressed otherwise. The reproduction of any information generated by engineers, architects, or other consultants on any sketches, drawings, or photographs is for the express purpose of coordination and ease of reference only. Inclusion of said information on any drawings or other documents does not constitute a representation by Walter Levison to the sufficiency or accuracy of said information. Unless expressed otherwise: a. information contained in this report covers only those items that were examined and reflects the conditions of those items at the time of inspection; and b. the inspection is limited to visual examination of accessible items without dissection, excavation, probing, or coring. There is no warranty or guarantee, expressed or implied, that problems or deficiencies of the plants or property in question may not arise in the future. Loss or alteration of any part of this report invalidates the entire report. Arborist Disclosure Statement: Arborists are tree specialists who use their education, knowledge, training, and experience to examine trees, recommend measures to enhance the beauty and health of trees, and attempt to reduce the risk of living near trees. Clients may choose to accept or disregard the recommendations of the arborist, or to seek additional advice. Arborists cannot detect every condition that could possibly lead to the structural failure of a tree. Tree are living organis ms that f ail in ways we do not fully understand. Conditions are often hidden within trees and below ground. Arborist cannot guarantee that a tree will be healthy or safe under all circumstances, or for a specified period of time. Likewise, remedial treatments, like any medicine, cannot be guaranteed. Treatment, pruning, and removal of trees may involve considerations beyond the scope of the arborist’s services such as property boundaries, property ownership, site lines, disputes between neighbors, and other issues . Arborists cannot take such considerations into account unless complete and accurate information is disclosed to the arboris t. An arborist should then be expected to reasonably rely upon the completeness and accuracy of the information provided. Trees c an be managed, but they cannot be controlled. To live near trees is to accept some degree of risk. The only way to eliminate all risk associated with trees is to eliminate the trees. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 27 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 9.0 Certification I hereby certify that all the statements of fact in this report are true, complete, and correct to the best of my knowledge and belief, and are made in good faith. Signature of Consultant DIGITAL BADGES: ISA CERTIFIED ARBORIST CREDENTIAL: https://certificates.isa-arbor.com/f1918723-df46-48cc-ace2-c12625530fec?record_view=true ISA TREE RISK ASSESSMENT QUALIFIED (TRAQ): https://certificates.isa-arbor.com/d180515f-ab75-440b-9c66-106005e3cf10?record_view=true#gs.hpb30w ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 28 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 10.0 Digital Images WLCA archived new digital images of the trees on 2/1/2022: Tree Tag Image Tree Tag Image 31 32 ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 29 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Tree Tag Image Tree Tag Image 33 34 ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 30 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Tree Tag Image Tree Tag Image 35 36 Flux at the base of this oak (#36) appears to be caused by chronic moist or wet conditions at the base. Removal of irrigation, ivy, and soil to expose the root flare may allow the tree to normalize and reduce or stop flux exudation. See recommendations for details. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 31 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Tree Tag Image Tree Tag Image 37 38 Note the very tight fork conditions where mainstems are squeezed together in an unusual formation. The only viable maintenance solution for this situation is to install through-bolt type threaded brace rods per ANSI A300 specs, to attempt to mitigate risk to some degree. Arborist cable installations may or may not also be warranted. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 32 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Tree Tag Image Tree Tag Image 38 Tree 38 has been overpruned, but is still a viable and important tree. 38 ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 33 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Tree Tag Image Tree Tag Image 38 Looking northwest ”ward at the open soil root zone between tree 38 trunk at right edge of image, and the existing residence footprint at the left edge of image. The proposed new residence will encroach to roughly 12 feet from the trunk edge. This means that if the current plan is built as proposed, the chain link TPZ/RPZ fencing would be erected at 7 feet out from the trunk of the tree, in order to leave a 5 foot wide construction corridor between fence and residence foundation edge. Soil protection buffer installation will be required, in order to avoid soil compaction from foot traffic and/or machinery use in the construction corridor. The buffer consists typically of a layer of wood chips 6” to 12” thickness, lain over a geotextile pinned down over the bare soil. This type of buffer helps mitigate soil compaction and root zone damage to woody and absorbing roots that extend out a great distance from the tree trunk, typically as far as 2x to 5x the canopy dripline radius. --- ------------------------------------------------------- ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 34 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 11.0 Tree Data Table NOTE 1: Fruit and nut trees measuring less than 18” diameter (total of all mainstems) both on the site and on adjacent neighbor properties were excluded from this study as “exemption trees” per the Town tree ordinance. NOTE 2: Tree preservation suitability ratings (TPS) are determined independently from and irrespective of current proposed site construction work. Tree Tag Number Genus & Species Common Name Trunk1 Diameter Trunk2 Diameter Trunk3 Diameter Sum of All Trunk Diameters Height & Canopy Spread (Ft.) Health & Structural Rating (100% Each) Overall Condition Rating (0 to 100%) (R)emove Tree (S)ave Tree (D)isposition Unclear Tree Preservation Suitability Ratings (TPS) Lopsided Canopy (note direction) Trunk Lean (note direction ) Girdling Roots Root Flares Buried in Fill Soil Pests and Disease Presence, and Other Notes SUGGESTED ROOT PROTECTION FENCE RADIUS (Ft.) MAINTENANCE AND PROTECTION CODES 31 Quercus agrifolia NEIGHBOR TREE Coast live oak 13.2 -- -- 13.2 25/18 50/40 45% Fair X Mod West West Tree was hack pruned below PG&E high voltage wires. Needs to be pruned to raise canopy to 14 foot min. for vehicle clearance. Fence off at the edge of the proposed driveway footprint. TB, TPZ, prune to clear 14 feet of vertical airspace. 32 Quercus agrifolia NEIGHBOR TREE Coast live oak 7.4 -- -- 7.4 22/18 60/50 53% Fair X Mod North North Harp form (bow form) canopy leans over driveway. Requires clearance pruning. Fence off at the edge of the proposed driveway footprint. TB, TPZ, prune to clear 14 feet of vertical airspace. 33 Cedrus deodara NEIGHBOR TREE Deodar cedar 34.9 -- -- 34.9 60/50 80/65 72% Good X Good Has been pruned to clear the PG&E high voltage wires. Located in irrigated turf = good. Fence off at edge of driveway. Fence off at the edge of the proposed driveway footprint. ------------------ 34 Quercus agrifolia Coast live oak 6.7 -- -- 6.7 14/7 10/10 10% Very Poor X Poor North Tree was topped at 9 feet, and grew again to 14 feet. Tree is basically a tall cut stump. Fence off at the edge of the proposed driveway footprint. TB, TPZ 35 Quercus agrifolia Coast live oak 12.5 --- --- 12.5 40/20 70/70 70% Good X Good North North Extends far over driveway, but at a high elevation with no conflicts expected. Will need to protect root system with chain link fencing. Fence off at the edge of the proposed driveway footprint. TB, TPZ ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 35 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Tree Tag Number Genus & Species Common Name Trunk1 Diameter Trunk2 Diameter Trunk3 Diameter Sum of All Trunk Diameters Height & Canopy Spread (Ft.) Health & Structural Rating (100% Each) Overall Condition Rating (0 to 100%) (R)emove Tree (S)ave Tree (D)isposition Unclear Tree Preservation Suitability Ratings (TPS) Lopsided Canopy (note direction) Trunk Lean (note direction ) Girdling Roots Root Flares Buried in Fill Soil Pests and Disease Presence, and Other Notes SUGGESTED ROOT PROTECTION FENCE RADIUS (Ft.) MAINTENANCE AND PROTECTION CODES 36 Quercus agrifolia Coast live oak 17.2 -- -- 17.2 40/35 60/60 60% Fair X Poor if current site plan built. Modera te if site plan adjust to push residen ce to 14 feet from trunk edge. East East Black flux exudations from lower trunk bark indicate likely Phytophthora infection from wet or moist conditions caused by ivy, irrigation, and soil mound presence over root crown. Needs root crown excavation (RCX). Note proposed south roof is 15’8”, and canopy hangs to 12’ at low point where conflicts. Need to prune to raise canopy elevation to 16 feet by cutting 1” and 2” dia branches. Suggest push proposed residence to 14 feet from trunk edge, and fence off the tree at 9 feet from trunk edge. TB, TPZ. Remove ivy, remove irrigation within 20 feet of tree, and hand- dig out the soil around base of trunk to expose the natural flaring buttress roots (“root crown excavation” or “RCX”). Remove 1” and 2” diameter branches from north side of the canopy to clear airspace to 16 feet elevation above grade for new south roof finish elev. 37 Pyracantha sp. (shrub) Pyracantha species 7.3 -- -- 7.3 15/16 40/30 32% Poor X n/a This is actually a shrub, but is still regulated by Town of Los Gatos. To be removed. Mitigate at 3:1 (install three (3) 15 gallon or 24” box size tree plantings on site per Town canopy replacement requirement. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 36 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Tree Tag Number Genus & Species Common Name Trunk1 Diameter Trunk2 Diameter Trunk3 Diameter Sum of All Trunk Diameters Height & Canopy Spread (Ft.) Health & Structural Rating (100% Each) Overall Condition Rating (0 to 100%) (R)emove Tree (S)ave Tree (D)isposition Unclear Tree Preservation Suitability Ratings (TPS) Lopsided Canopy (note direction) Trunk Lean (note direction ) Girdling Roots Root Flares Buried in Fill Soil Pests and Disease Presence, and Other Notes SUGGESTED ROOT PROTECTION FENCE RADIUS (Ft.) MAINTENANCE AND PROTECTION CODES 38 Quercus agrifolia LARGE PROTECT ED TREE “LPT” Coast live oak 30.0 -- -- 30.0 45/60 80/50 58% X Mod, if site plan built as propos -ed. Bark inclusion type forks noted at 5 feet to 8 feet elevation, which will require installation of arborist cabling and/or through- bolt brace rods per ANSI A300 standards to reduce risk of splitout, though in reality, the risk rating may not be able to be reduced to “low” even with installation of these items. Proposed new residence is within critical root zone of tree at 12 feet offset from trunk, but is OK if use a soil protection buffer between residence and TPZ fence line. Canopy extends over roof by 15 horizontal feet, at an elevation of 12 and 17 feet elevation, so need to remove one (1) 6” diameter limb at the attachment point where it extends westward from trunk at 7 feet elevation on trunk, to clear the new roof which will be 15’8” at high point. Fence off at 7 feet west of trunk edge, and then install soil protection buffer between 7 feet and 12 feet west of trunk edge, as indicated on the CTA tree map in green highlight. TB, TPZ, and install RB (root buffer/soil buffer) between 7 feet and 12 feet west of trunk edge. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 37 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Overall Tree Condition Ratings / Breakdown of Numeric Ranges (New, Per Guide for Plant Appraisal, 10th Edition): 00 - 05% = Dead 06 - 20% = Very Poor 21 – 40% = Poor 41 – 60% = Fair 61 – 80% = Good 81 – 100% = Exceptional ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 38 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Tree Conservation Suitability (TCS) Ratings 2 A tree’s suitability for conservation is determined based on its health, structure, age, species and disturbance tolerances, proximity to proposed cutting and filling, proximity to proposed construction or demolition, and potential longevity, using a scale of good, fair, or poor (Fite, K, and Smiley, E. T., 2016). The following list defines the rating scale. Note that if proposed site work can be offset to farther linear distances from a tree’s trunk edge, a tree’s TCS rating may be elevated by one rating tier, given that there would be a corresponding reduction in expected future root zone impacts. TPS Ratings Range of values Good 80-100 Trees with good health, good structural stability and good expected longevity after construction. Moderate 60-79 Trees with fair health and/or structural defects that may be mitigated through treatment. These trees require more intense management and monitoring, before, during, and after construction, and may have shorter life expectancy after development. Poor <59 Trees are expected to decline during or after construction regardless of management. The species or individual may possess characteristics that are incompatible or undesirable in landscape settings or unsuited for the intended use of the site. TCS Ratings Worksheet Factors (Total Possible: 100 Points) Health (1-15) Root Cut/Fill Distance from Trunk (1-15) Structure Defects (1-15) Construction Tolerance of the tree species (1-15) Age relative to typical species lifespan (1-10) Location of construction activity (1-10) Soil quality/characteristics (1-10) Species desirability (1-10) 2 Derived from Fite and Smiley, 2016. Best Management Practices: Managing Trees During Construction, 2nd Edition. International Society of Arboriculture. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 39 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved Tree Maintenance and Protection Codes Used in Data Table: RPZ: Root protection zone fence, chain link, with 2" diameter iron posts driven 24" into the ground, 6 to 8 feet on center max. spacing. Alternative material: chain link fence panels set over concrete block-type footings, with the fence panels wired to steel pins pounded 24 inches into the ground at both ends of each panel. RB: Root buffer consisting of wood chip mulch lain over existing soil as a 12 inch thick layer, overlain with 1 inch or greater plywood strapped together with metal plates. This root buffer or soil buffer should be placed over the entire width of the construction corridor between tree trunks and construction. RP: Root pruning. Prune woody roots measuring greater than or equal to 1 inch diameter by carefully back-digging into the soil around each root using small hand tools until an area is reached where the root is undamaged. Cleanly cut through the root at right angle to the root growth direction, using professional grade pruning equipment and/or a Sawzall with wood pruning blade. Backfill around the cut root immediately (same day), and thoroughly irrigate the area to saturate the uppermost 24 inches of the soil profile. BDRP: Back-dig root pruning: Hand-dig around the broken root, digging horizontally into the open soil root zone until a clean, unbroken, unshattered section of the root is visible. Proceed as per ‘root pruning’. RCX: Root crown excavation. Retain an experienced ISA-Certified arborist to perform careful hand-digging using small trowels or other dull digging tools to uncover currently-buried buttress root flares. Digging shall occur between trunk edge and at least two (2) feet horizontal from trunk edge. The final soil elevation will be at a level such that the tree’s buttress roots visibly flare out from the vertical trunk. TB: Trunk buffer consists of 20-40 wraps of orange plastic snow fencing to create a 2 inch thick buffer over the lowest 8 feet of tree trunk (usually takes at least an entire roll of orange fencing per each tree). Lay 2X4 wood boards vertically, side by side, around the entire circumference of the trunk. Secure buffer using duct tape (not wires). F: Fertilization with slow-release Greenbelt 22-14-14 tree formula, as a soil injection application using a fertilizer injection gun. This brand and formulation is commonly used by reputable tree care companies in the Bay Area. Apply at label rate and injection hole spacing. M: 4-inch thick layer of chipper truck type natural wood chips (example source: Lyngso Garden Supply, self pick-up). Do not use bark chips or shredded redwood bark. W: Irrigate using various methods to be determined through discussion with General Contractor. Irrigation frequency and duration to be determined through discussion and/or per directions in this report. Native oak species typically require 1x/month irrigation, while other tree species tend to prefer 2x/month or 4x/month moderate to heavy irrigation during construction. P: Pruning per specifications noted elsewhere. All pruning must be performed only under direct site supervision of an ISA Certified Arborist, or performed directly by an ISA Certified Arborist, and shall conform to all current ANSI A300 standards. MON: A Project Arborist must be present to monitor specific work as noted for each tree. ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WE-3172A c ell (415) 203-0990 / walterslevisonjr@yahoo.com 40 of 40 Site Address: 15602 Benedict Lane Version: 02/07/2022 Registered Member, American Society of Consulting Arborists and Member of the International Society of Arboriculture  Walter Levison 2022 All Rights Reserved 12.0 Tree Location & Protection Fence Map Mark-up The CTA marked up the applicant’s sheet A-00.01 “Proposed Site Plan” by AMS Design, dated September, 2021. The markups added to the applicant’s document include: • Numeric tree tag numbers noted in large font size. • Approximate canopy driplines shown in true scale, in relation to proposed new work. • Purple highlight = proposed new residence massing inside the tree #36 critical root zone. Possible decline/death of tree if built out at this location. • Green highlight = Author’s suggested area to install a 6” to 12” thick soil protection buffer between the protective fence around tree #38, and the foundation edge of the proposed new residence, to prevent unnecessary soil compaction in the area of the tree #38 root zone where horizontally woody roots extend to great distance away from the trunk. • Red highlight = Canopy dripline of tree #38 encroachment over the proposed new finish roof footprint. • Red dashed heavy lines = the CTA’s suggested root protection zone (RPZ) chain link fence routing for protection of horizontally- extended woody roots. The routing indicated is non-optimal, and would normally be routed at 15 to 25 feet radius offset from the trunk edge of each tree being retained to optimize tree survival and tree stability. Some redesign is recommended if trees #36 and #38 are to be retained in their current condition ratings. 13.0 Attached: CTA Tree Appraisal Worksheet per 10th Edition Guide for Plant Appraisal Walter Levison, Consulting Arborist <walterslevisonjr@yahoo.com> Cell: (415) 203-0990 1 of 3 Line 9 Line 10 Line 11 Tree Tag #Name (Initials)WCISA Speces Group Classification Booklet PageHealth (Weighted 0.15)Structure (Weighted 0.70)Form (Weighted 0.15)Overall Condition Rating (OCR) "Weighted Method" Diameter Inches at 4.5 ft. Above GradeFunctional LimitationsExternal LimitationsWCISA Species Group NumberTrunk Square Inches for Replacement-Size Specimen of This SpeciesAverage SF Bay Area Cost of 24 Inch Box Tree (2019)(UTC) Unit Tree Cost per Sq Inch (M Divided by L)Trunk Area (TA) ((dia. x dia.) x 0.785)Basic Functional Replacement Cost (BFRC) = (OxN)Depreciated Functional Replacement Cost (DFRC) = PxGxIxJRounded-off Appraised Values31 Qa 30 0.5 0.4 0.7 46%13.2 40%90%3 3.8 $250.00 $65.79 136.78 8,999$ 1,490$ $1,490 32 Qa 30 0.6 0.5 0.5 52%7.4 40%90%3 3.8 $250.00 $65.79 42.99 2,828$ 524$ $520 33 Cd 8 0.8 0.65 0.9 71%34.9 80%90%3 3.8 $250.00 $65.79 956.14 62,904$ 32,156$ $32,200 34 Qa 30 0.1 0.1 0.1 10%6.7 20%90%3 3.8 $250.00 $65.79 35.24 2,318$ 42$ $40 35 Qa 30 0.7 0.7 0.8 72%12.5 70%90%3 3.8 $250.00 $65.79 122.66 8,069$ 3,635$ $3,630 36 Qa 30 0.6 0.6 0.7 62%17.2 60%90%3 3.8 $250.00 $65.79 232.23 15,279$ 5,074$ $5,100 Valuation Appraisal Worksheet Based on Guide for Plant Appraisal, 10th Edition , 2nd Printing (2019) "Functional Replacement Method / Trunk Formula Technique" 15602 Benedict Lane, Los Gatos, California 2/7/2022 Depreciation Factors Walter Levison, Consulting Arborist <walterslevisonjr@yahoo.com> Cell: (415) 203-0990 2 of 3 Line 9 Line 10 Line 11 Tree Tag #Name (Initials)WCISA Speces Group Classification Booklet PageHealth (Weighted 0.15)Structure (Weighted 0.70)Form (Weighted 0.15)Overall Condition Rating (OCR) "Weighted Method" Diameter Inches at 4.5 ft. Above GradeFunctional LimitationsExternal LimitationsWCISA Species Group NumberTrunk Square Inches for Replacement-Size Specimen of This SpeciesAverage SF Bay Area Cost of 24 Inch Box Tree (2019)(UTC) Unit Tree Cost per Sq Inch (M Divided by L)Trunk Area (TA) ((dia. x dia.) x 0.785)Basic Functional Replacement Cost (BFRC) = (OxN)Depreciated Functional Replacement Cost (DFRC) = PxGxIxJRounded-off Appraised Values Valuation Appraisal Worksheet Based on Guide for Plant Appraisal, 10th Edition , 2nd Printing (2019) "Functional Replacement Method / Trunk Formula Technique" 15602 Benedict Lane, Los Gatos, California 2/7/2022 Depreciation Factors 37 (This is not a "tree" listed in the western chapter ISA database of tree species. It is considered a "shrub"). 0.4 0.3 0.4 33%7.3 40%90%3 3.8 $250.00 $65.79 41.83 2,752$ 327$ $330 38 Qa 30 0.8 0.5 0.8 59%30 70%90%3 3.8 $250.00 $65.79 706.50 46,480$ 17,277$ $17,300 Walter Levison, Consulting Arborist <walterslevisonjr@yahoo.com> Cell: (415) 203-0990 3 of 3 Line 9 Line 10 Line 11 Tree Tag #Name (Initials)WCISA Speces Group Classification Booklet PageHealth (Weighted 0.15)Structure (Weighted 0.70)Form (Weighted 0.15)Overall Condition Rating (OCR) "Weighted Method" Diameter Inches at 4.5 ft. Above GradeFunctional LimitationsExternal LimitationsWCISA Species Group NumberTrunk Square Inches for Replacement-Size Specimen of This SpeciesAverage SF Bay Area Cost of 24 Inch Box Tree (2019)(UTC) Unit Tree Cost per Sq Inch (M Divided by L)Trunk Area (TA) ((dia. x dia.) x 0.785)Basic Functional Replacement Cost (BFRC) = (OxN)Depreciated Functional Replacement Cost (DFRC) = PxGxIxJRounded-off Appraised Values Valuation Appraisal Worksheet Based on Guide for Plant Appraisal, 10th Edition , 2nd Printing (2019) "Functional Replacement Method / Trunk Formula Technique" 15602 Benedict Lane, Los Gatos, California 2/7/2022 Depreciation Factors Total Appraised Value of the Study Trees Proposed to be Retained and Protected $60,610 Notes: 1. OVERALL CONDITION RATING RANGE per the new 10th edition, 2nd Printing, of Guide for Plant Appraisal (2019): Excellent: 81-100% Good: 61-80% Fair: 41-60% Poor: 21-40% Very Poor: 6-20% Dead: 0-5% 2. MULTI STEM TREES: For trees with multiple mainstems, the total of all mainstem cross sectional areas was used as the "trunk area" calculation. For trees with mainstems larger than 30 inches diameter each, an "adjusted trunk area" or "ATA" value is used, from a table of values in the older 9th edition of the Guide for Plant Appraisal.The ATA value is smaller than the actual trunk diameter, and brings the tree's appraised dollar value down to a more "reasonable" level. 3. NEIGHBOR TREES: For neighbor-owned trees that were not accessible by the CTA, the trunk diameter was estimated from a distance to the best of the CTA's ability. 4. CONDITION RATINGS / APPRAISAL TABLE VS. DATA TABLE: Because of the new appraisal methods outlined in the 2019 edition of the Guide for Plant Appraisal, 10th edition 2nd printing, the condition ratings calculated in the "Overall Condition Rating / Weighted Method" column, and the data noted in the health and structure columns of this spreadsheet (with calculations embedded), may in some cases be slightly different from data in the CTA's arborist report tree data table. The CTA attempted to keep overall condition rating values as consistent as possible between the two data tables (i.e. the appraisal data table and the tree data table in the arborist report). This Page Intentionally Left Blank From: ROBERT GORE <> Sent: Monday, September 19, 2022 9:56 PM To: Planning Comment <PlanningComment@losgatosca.gov> Subject: 15602 Benedict Lane, Application S-21-036 Hello, I am the owner of , which is the property next door to Alireza and Shadi. My wife and I had a nice meeting with them regarding their new house plans, and we are fully supportive of their new house. We are very excited for them, and wish for you allow them to proceed exactly as planned. The new house with our new neighbors will be a welcome addition for our street and neighborhood. Respectfully yours, Robert L. Gore EXHIBIT 8 This Page Intentionally Left Blank 1/8 INCH = 1 FEET 0 2 4 6 8 10 20 30 GRAPHIC SCALE :1 1/2 : 121 1/2 : 12WwWwWE / LE / LE / LFFFFFFFFFFFFFF F F F F FFFFFF FFFFFFFFFFFFFFF F SSSSS8'-4" 20'11'3'8'-1"28'-7"32'-9"8'-5" 8'-6"13'-9" 8'-1"28'-6"8' 8' 2' 1'-4" 1'-4" 6'-6" 6'-9"25'30'9'20'1'NEW 200 AMP.ELEC. METERCOOLING UNITEXISTING WATER METER TO BE RELOCATED OUTSIDE OF THE BENEDICT LANE RIGHT-OF-WAY PER CONDITION OF APPROVAL. 77' 77'125.35'125.16'BENEDI CT LA NE, WALK WAY DRIVE WAY FLAT ROOF MINIMUM ROOF SLOPE SHALL BE 1/4 INCH PER FOOT, I.E. 1 UNIT VERTICAL IN 48 UNITS HORIZONTAL (2% SLOPE). CRC R905.4.2, R905.9.1, R905.11.1, R905.12.1, R905.13.1, R905.14.1, AND R905.15.1 8' SIDE SETBACK20' REAR SETBACK 8' SIDE SETBACK25' FRONT SETBACKSIDE WALK CURB SIDE PROPERTY LINE TO BNEDICT LN. CENTER LINE DIM.25' P.L.E 8'' TREE 7'' TREE 11'' TREE 18'' TREE 32'' TREE TO STAY TO STAY TO STAY TO BE REMOVED TO STAY "EX" WOODEN FENCE MULCH MULCH 6'' TREE TO BE REMOVED "N" TREE TO BE PLANED. COA ST OLIVE OA K PYRACANTHA SPECIES COAST OLIVE OAK COAST OLIVE OAK COAST OLIVE OAK ~ (E)SS LATERAL SERVICE APPROXIMATE LOCATION FIELD VERIFY NEW SSCO ROOF DOWN-SPOUT TREE 31 TREE 34 TREE 35 TREE 32 TREE 33 TREE 36 TREE 37 TREE 38 COAST OLIVE OAK DEODA R CEDAR424-22-009424-22-007ALL NEW, RELOCATED, OR TEMPORARILY REMOVED UTILITY SERVICES, INCLUDING TELEPHONE, ELECTRIC POWER AND ALL OTHER COMMUNICATIONS LINES SHALL BE INSTALLED UNDERGROUND UNCOVERED PORCH (PAVED AREA) 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. PROJECT ID: DATE: SCALE: DRAWN BY: REVISION TABLE: AMS DESIGN DESIGN Azadeh Masrour REVISION DATE BY DEP A -00.01 1/8'' = 1' COVER SHEET/ PROPOSED SITE PLAN BENEDICT RESIDENCE 15602 BENEDICT LN., LOS GATOS, CA 95032 JAN.2022 S.A.PLN01 ---- SEP.2021 S.A. VICINITY MAP: PROPERTY LOCATION / NTS424-22-008 NEW CONSTRUCTION 15602 BENEDICT LN., LOS GATOS, CA 95032 R-1:8 R - 3 / U V - B ONE (1) STORY SPRINKLERED ASSESSOR'S PARCEL NUMBER: PROJECT TYPE: PROJECT LOCATION: ZONING: OCCUPANCY GROUP: CONSTRUCTION TYPE: NUMBER OF FLOORS: FIRE PROTECTION: PROJECT DATA: C ODE EDITIONS: A. B. C. D. E. F. G. H. I. CALIFORNIA RESIDENTIAL: CALIFORNIA BUILDING: CALIFORNIA MECHANICAL: CALIFORNIA PLUMBING: CALIFORNIA ELECTRICAL: CALIFORNIA ENERGY: CALIFORNIA FIRE: CALIFORNIA GREEN BUILDING: ANY OTHER APPLICABLE LOCAL AND STATE LAWS AND REGULATIONS. 2019 EDITION 2019 EDITION 2019 EDITION 2019 EDITION 2019 EDITION 2019 EDITION 2019 EDITION 2019 EDITION -DEMO AN EXISTING ONE-STORY HOUSE. -CONSTRUCT A NEW ONE-STORY CUSTOM HOME, INCLUDING 4 BEDROOMS, 3.5 BATH, 1 LAUNDRY AND 2CAR GARAGE. -DEMO THE EXISTING SINGLE FAMILY RESIDENCE AND DETACHED GARAGE. SCOPE OF WORK: A-00.01:COVER SHEET / PROPOSED SITE PLAN A-00.01(A):ARBORIST REPORT A-00.01(B):ARBORIST REPORT BT1:BOUNDARY AND TOPOGRAPHIC MAP BT2:BOUNDARY AND TOPOGRAPHIC MAP C-1:COVER SHEET / NOTE C-2:GRADING AND DRAINAGE PLAN C-3:DETAILS C-4:NOTES C-5:CONSTRUCTION MANAGEMENT & EROSION CONTROL PLAN RA-01.01:EXISTING FLOOR PLAN RA-02.01:EXISTING ELEVATIONS A-01.01:PROPOSED FLOOR PLAN A-02.01:PROPOSED ELEVATIONS A-02.02:PROPOSED ELEVATIONS A-03.01:PROPOSED SECTIONS / SCHEMATIC ELEVATIONS A-04.01:FLOOR AREA DIAGRAM A-05.01:EXTERIOR MATERIAL BOARD / STREET SCAPE ELEVATION CB-01:CLEAN BAY BLUE PRINT DRAWING INDEX: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. GENERAL NOTES: NORTH LEGEND: BLDG FOOTPRINT LINE PROPERTY LINE OWNER:SHADI ZOMORODI 15602 BENEDICT LN., LOS GATOS, CA 95032 SHADI_ZOMORRODI@YAHOO.COM DESIGNER:AMS DESIGN (415)254-1606 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 AZADEH@AMSDESIGNLLP.COM STRUCTURAL:AMS DESIGN (415)254 -2634 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 ARMIN@AMSDESIGNLLP.COM PROJECT CONTACT: LOT AREA:9645 SQF "E" LIVING AREA:1387 SQF "E" GARAGE:620 SQF "E" BUILDING AREA:2007 SQF "N" LIVING AREA:2882 SQF "N" GARAGE:436 SQF "N" TOTAL BUILDING:3318 SQF UNCOVERED PORCH:438 SQF AREA CALCULATION: THE ALLOWABLE LIVING FAR: 0.35 - ((A-5)/25) X 0.20) = 0.35 - ((9.645-5)/25) X 0.20) = 0.313 X 9645 = 3,018.885 SF. THE ALLOWABLE GARAGE FAR: 0.10 - ((A-5)/25) X 0.07) = 0.10 - ((9.645-5)/25) X 0.07) = 0.087 X 9645 = 839.115 SF. "EX" LOT COVEARGE: (2007/9645) X 100 = 20.80 % "N" LOT COVEARGE: (3318/9645) X 100 = 34.40 % 1 5 6 0 2 B E N E D I C T L N . L O S G A T O S, C A 95032 A SEPARATE BUILDING PERMIT IS REQUIRED FOR THE PV SYSTEM THAT IS REQUIRED BY THE CALIFORNIA ENERGY CODE PERFORMANCE OR PRESCRIPTIVE STANDARDS. THE SEPARATE PV SYSTEM PERMIT MUST BE FINALED PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY THIS RESIDENCE WILL COMPLY WITH THE TOWN’S ALL ELECTRIC APPLIANCE, ELECTRIC VEHICLE AND ENERGY STORAGE SYSTEM REQUIREMENTS IN ACCORDANCE WITH TOWN CODE SECTION 6.70.020 AND 6.120.020. A SPRINKLER SYSTEM WILL BE INSTALLED AS A DEFERRED SUBMITTAL. 1.POTABLE WATER SUPPLIES SHALL BE PROTECTED FROM CONTAMINATION CAUSED BY FIRE PROTECTION WATER SUPPLIES. IT IS THE RESPONSIBILITY OF THE APPLICANT AND ANY CONTRACTORS AND SUBCONTRACTORS TO CONTACT THE WATER PURVEYOR SUPPLYING THE SITE OF SUCH PROJECT, AND TO COMPLY WITH THE REQUIREMENTS OF THAT PURVEYOR. SUCH REQUIREMENTS SHALL BE INCORPORATED INTO THE DESIGN OF ANY WATER-BASED FIRE PROTECTION SYSTEMS, AND/OR FIRE SUPPRESSION WATER SUPPLY SYSTEMS OR STORAGE CONTAINERS THAT MAY BE PHYSICALLY CONNECTED IN ANY MANNER TO AN APPLIANCE CAPABLE OF CAUSING CONTAMINATION OF THE POTABLE WATER SUPPLY OF THE PURVEYOR OF RECORD. FINAL APPROVAL OF THE SYSTEM(S) UNDER CONSIDERATION WILL NOT BE GRANTED BY THIS OFFICE UNTIL COMPLIANCE WITH THE REQUIREMENTS OF THE WATER PURVEYOR OF RECORD ARE DOCUMENTED BY THAT PURVEYOR AS HAVING BEEN MET BY THE APPLICANT(S). 2019 CFC SEC. 903.3.5 AND HEALTH AND SAFETY CODE 13114.7. 2.NEW AND EXISTING BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. THESE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, ADDRESS NUMBERS SHALL BE PROVIDED IN ADDITIONAL APPROVED LOCATIONS TO FACILITATE EMERGENCY RESPONSE. ADDRESS NUMBERS SHALL BE ARABIC NUMBERS OR ALPHABETICAL LETTERS. NUMBERS SHALL BE A MINIMUM OF 4 INCHES (101.6 MM) HIGH WITH A MINIMUM STROKE WIDTH OF 0.5 INCH (12.7 MM). WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. ADDRESS NUMBERS SHALL BE MAINTAINED. CFC SEC. 505.1. 3.ALL CONSTRUCTION SITES MUST COMPLY WITH APPLICABLE PROVISIONS OF THE CFC CHAPTER 33 AND OUR STANDARD DETAIL AND SPECIFICATION S1-7. PROVIDE APPROPRIATE NOTATIONS ON SUBSEQUENT PLAN SUBMITTALS, AS APPROPRIATE TO THE PROJECT. CFC CHP. 33. FIRE NOTES: SMA EXHIBIT 9 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. PROJECT ID: DATE: SCALE: DRAWN BY: REVISION TABLE: AMS DESIGN DESIGN Azadeh Masrour REVISION DATE BY DEP BENEDICT RESIDENCE 15602 BENEDICT LN., LOS GATOS, CA 95032 JAN.2022 S.A.PLN01 ---- SEP.2021 S.A. A-00.01(A) N.T.S ARBORIST REPORT SMA 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. PROJECT ID: DATE: SCALE: DRAWN BY: REVISION TABLE: AMS DESIGN DESIGN Azadeh Masrour REVISION DATE BY DEP BENEDICT RESIDENCE 15602 BENEDICT LN., LOS GATOS, CA 95032 JAN.2022 S.A.PLN01 ---- SEP.2021 S.A. A-00.01(B) N.T.S ARBORIST REPORT SMA SMP ENGINEERS ’ ’’ ’ “” ’ ’ ’ ALL NEW, RELOCATED, OR TEMPORARILY REMOVED UTILITY SERVICES, INCLUDING TELEPHONE, ELECTRIC POWER AND ALL OTHER COMMUNICATIONS LINES SHALL BE INSTALLED UNDERGROUND. BB AA CC SMP ENGINEERS SMP ENGINEERS SECTION Z-Z Z SECTION W-W W PLAN W Z · · · · · · · · · · · · · · · · ­­ · ­ · · · ·­ · · · · ·���� · ­ ­ · SMP ENGINEERS · · mo ailure · · · · · · · · · · · SMP ENGINEERS PLAN VIEW SECTION A - A STORM INLET SEDIMENT TRAP-FIBER ROLLS CONCRETE WASHOUT AREA SITE PLAN 1"=10' EROSION AND SEDIMENT CONTROL NOTES AND MEASURES EXISTING DRAINAGE INLET PROTECTION PLAN STABILIZED CONSTRUCTION ENTRANCE FIBER ROLL NOTES FIBER ROLL (TO BE MAINTAINED) Maintenance PLAN PROFILE SECTION B-B TEMPORARY COVER ON STOCK PILE PERSPECTIVE 1/4 INCH = 1 FEET 0 1 2 3 4 5 10 15 GRAPHIC SCALE : D/WWH REF.W05-2640W05-2640W06-2750W08-41050W06-2750D11-3068 W03-3040W03-3040W03-3040W01-2630W03-3040W07-3839D10-2868W04-3040W04-3040D14-4068D08-2868D09-2768D01-2468D13-2068D02-2868 D04-2468 D06-2868 D05-2468D07-2068W03-3040 W02-3038 D12-6068 W07-3839 W07-3839 5068 3033 D03-2768 2268D15-16080 W09-3030 D16-2868 D16-28680'-5"3'-0"1'-4"0'-8"3'-0"9'-0"3'-7"2'-6"1'-3"0'-11"3'-0"9'-9"1'-9"3'-0"2'-7"2'-7"0'-2"4'-10"0'-2"2'-7"2'-4"4'-0"3'-0"0'-6"3'-0"2'-2" 3'-11"7'-10"3'-0"1'-1"4'-9"11'-11"3'-1"7'-4"13'-8"40'-9"1'-0"3'-8"0'-8"3'-8"3'-2"6'-0"1'-6" 19'-8"2'-10"4'-9"12'-8" 39'-11"1'-3"2'-6"1'-3"5'-2"0'-10"2'-6"1'-0"1'-6"3'-0"0'-2"3'-0"1'-6"3'-4"2'-8"0'-8"3'-8"0'-9"14'-6"9'-2"11'-1"34'-9"5'-4"0'-8"4'-0"16'-0"4'-0" 24'-0"2'-9"2'-8"3'-0"8'-5"19'-7"28'-0"7'-1"3'-0"5'-7"2'-8"2'-8"3'-0"28'-0"22'-8" X 14'-1" 1'-4" X 1'-8" 2'-8" X 5'-0" 12'-3" X 13'-3" 26'-7" X 8'-10" 19'-0" X 10'-5" 12'-3" X 11'-3" 3'-4" X 10'-1" 6'-6" X 2'-9"1'-8" X 2'-9" 8'-7" X 7'-0" 23'-5" X 27'-4"ELEC. METERGAS METERCOOLING UNIT CLOSET CLOSET BATH BEDROOM CLOSET CLOSET BEDROOM WA.DR.LIVING KITCHEN LIVING HALL ATTIC ACCESS GARAGE 8' CEILING HEIGHT 8' CEILING HEIGHT 8' CEILING HEIGHT 8' CEILING HEIGHT 8' CEILING HEIGHT 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. PROJECT ID: DATE: SCALE: DRAWN BY: REVISION TABLE: LEGEND: EXISTING WALL TO BE REMOVED EXISTING WALL TO STAY AMS DESIGN DESIGN Azadeh Masrour REVISION DATE BY DEP EXISTING FLOOR PLAN RA-01.01 1/4'' = 1' BENEDICT RESIDENCE 15602 BENEDICT LN., LOS GATOS, CA 95032 JAN.2022 S.A.PLN01 ---- SEP.2021 S.A. NORTH ALL OF THE EXISTING STRUCTURE TO BE DEMO. SMA EXISTING FRONT (NORTH-WEST) ELEVATION SC : 1/4" = 1'-0" 1 EXISTING REAR (SOUTH-EAST) ELEVATION SC : 1/4" = 1'-0" 2 EXISTING RIGHT (SOUTH-WEST) ELEVATION SC : 1/4" = 1'-0" 3 EXISTING LEFT (NORTH-EAST) ELEVATION SC : 1/4" = 1'-0" 4 W08-41050W06-2750 D11-3068 W03-3040 D15-16080 W08-41050W06-2750 D11-3068 W03-3040 D15-16080 4 12 4 124 124 12 8'-0"14'-7"13'-7"1'-0"1'-8"2'-8"NATURAL GRADE LINE F.F. 13'-7" TOP HT. ABOVE F.F. 12'' ABOVE NATURAL GRADE 8'-0'' PLATE HT. ABOVE F.F. STUCCO STUCCO FIREPLACE SHINGLE ROOF W08-41050W06-2750 D11-3068 W03-3040 D15-16080 W08-41050W06-2750 D11-3068 W03-3040 D15-16080 4 12 4 12 4 12 W03-3040W02-3038 D12-6068 W07-3839W07-3839 W09-3030 D16-2868 W03-3040W02-3038 D12-6068 W07-3839W07-3839 W09-3030 D16-2868 8'-0"14'-7"13'-7"1'-0"2'-8"3'-0"2'-11"3'-8"NATURAL GRADE LINE F.F. 13'-7" TOP HT. ABOVE F.F. 12'' ABOVE NATURAL GRADE 8'-0'' PLATE HT. ABOVE F.F. FIREPLACE SHINGLE ROOF STUCCO 4 12 W03-3040W02-3038 D12-6068 W07-3839W07-3839 W09-3030 D16-2868 W03-3040W02-3038 D12-6068 W07-3839W07-3839 W09-3030 D16-2868 4 12 4 12 4 12 W05-2640W05-2640 W07-3839 D10-2868 W04-3040W05-2640W05-2640 W07-3839 D10-2868 W04-3040 8'-0"14'-7"13'-7"1'-0"2'-11"2'-8"2'-8"NATURAL GRADE LINE F.F. 13'-7" TOP HT. ABOVE F.F. 12'' ABOVE NATURAL GRADE 8'-0'' PLATE HT. ABOVE F.F. FIREPLACE SHINGLE ROOF SHINGLE ROOF STUCCO STUCCO W05-2640W05-2640 W07-3839 D10-2868 W04-3040W05-2640W05-2640 W07-3839 D10-2868 W04-3040 4 12 4 12 4 12 D16-2868D16-2868 W03-3040 W01-2630 W03-3040 W03-3040W03-3040 8'-0"14'-7"13'-7"1'-0"2'-8"2'-8"3'-8"NATURAL GRADE LINE F.F. 13'-7" TOP HT. ABOVE F.F. 12'' ABOVE NATURAL GRADE 8'-0'' PLATE HT. ABOVE F.F. STUCCO SHINGLE ROOF MOVED (& NEW) WINDOW MOVED ( & NEW) WINDOW NEW WINDOW D16-2868D16-2868 W03-3040 W01-2630 W03-3040 W03-3040W03-3040 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. PROJECT ID: DATE: SCALE: DRAWN BY: REVISION TABLE: RA-02.01 EXISTING ELEVATIONS AMS DESIGN DESIGN Azadeh Masrour REVISION DATE BY DEP 1/4'' = 1' BENEDICT RESIDENCE 15602 BENEDICT LN., LOS GATOS, CA 95032 JAN.2022 S.A.PLN01 ---- SEP.2021 S.A. SMA PROPOSED FLOOR PLAN SC : 1/4" = 1'-0" 1 1/4 INCH = 1 FEET 0 1 2 3 4 5 10 15 GRAPHIC SCALE :REF.2660262016080 3080 2660262026303050305010080 2880 2480 28802480288030802480 5080 20080 5080 2660262030809080 2480 2480 2480 2880 20802480 2880 2480 248024802880 2880 4690 10050 6080 2480 2480 ACCESS TO CRAWL SPACE 18" X 24" SLOPE18'-5"0'-4"2'-6"9'-6"2'-4"16'-0"2'-4" 20'-0"20'-0"3'-5" 3'-1"6'-0"5'-5"2'-9"10'-0"0'-6"0'-9"4'-6"0'-10" 14'-6"13'-3"6'-1"5'-9"20'-8" 60'-3" 1'-0"10'-0"3'-2"3'-0"5'-0"2'-0"20'-0"2'-0"5'-0"3'-4" 14'-2"40'-4" 60'-3" 2'-9"2'-8"0'-4" 5'-9"2'-8"3'-0"6'-6"3'-0"0'-7"6'-0"2'-6"0'-4"16'-8"15'-9"8'-10"2'-9"12'-4"56'-4"15'-4"3'-0"2'-0"7'-4"20'-4"7'-4"10'-3"18'-5"56'-4"4'-0"1'-3"1'-5"2'-4"2'-6"1'-5"1'-6"2'-4"1'-6"1'-6"2'-4" 3'-6"3'-6"3'-6" 6'-0" 7'-0"13'-0"1'-2"6'-6"11'-7"6'-8"1'-4"1'-4" 1'-4"1'-4"1'-4" 2'-0"1'-4"1'-4"1'-0"3'-0"3'-9"8'-0"4'-3"14'-1" X 12'-11" 4'-0" X 5'-0" 20'-0" X 20'-0" 5'-5" X 3'-8" 8'-4" X 5'-7" 39'-11" X 17'-11" 16'-9" X 19'-5" 8'-2" X 5'-0" 5'-0" X 8'-6" 12'-7" X 12'-0" 7'-0" X 9'-11" 14'-1" X 12'-0" 6'-0" X 13'-6" 10'-5" X 2'-4" 5'-5" X 7'-3" 8'-0" X 9'-8" 2'-8" X 3'-0" 5'-0" X 8'-6" 13'-6" X 18'-0" 7'-0" X 7'-0" 8'-4" X 4'-6"NEW 200 AMP.ELEC. METERCOOLING UNITBATH BEDROOM CLOSET GARAGE MASTER BDRM MASTER BATH BEDROOM WA.DR. ELEC FIREPLACE WET BAR KITCHEN & FAMILY BATH CLOSET WALK-IN CLOSET LAUNDRY MASTER BATHWALK-IN CLOSET POWDER LIVING WALK-IN CLOSET CLOSET ENTRY BEDROOM CLOSET 10' CEILING HEIGHT 10' CEILING HEIGHT10' CEILING HEIGHT 10' CEILING HEIGHT 10' CEILING HEIGHT 10' CEILING HEIGHT 10' CEILING HEIGHT 10' CEILING HEIGHT (N) 30" x 30" ATTIC ACCESS TMP/EGRESSTMP/OBSCURETMPTEMPERED GLAZING TO BE PROVIDED AT THE ANYGLAZING AT SWINGING, SLIDING AND/OR BI-FOLDDOORS THAT ARE INCLUDED.TMP/EGRESSTMPEGRESSTMP TMP TMP TMP/EGRESS TMP/OBSCUREIN THE ATTIC : 5' X 8' FURNACE PLATFORMLESS THAN 20' FROM THE ATTIC ACCESSOPENINGNEW FURNACE IN THE ATTICTHE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY(R309.1). CEILING OF THE PRIVATE GARAGE (ATTACHED OR LESS THAN 3' FROM DWELLING) SHALL BE SEPARATED FROM THE DWELLING UNIT ABOVE BY NOT LESS THAN A 5/8" TYPE X GYPSUM BOARD OR EQUIVALENT(T-R302.6) NO OBSTRUCTIONS ARE ALLOWED WITHIN 20'X20' GARAGE THE DOOR BETWEEN GARAGE AND LIVING AREA (D18) TO BE MINIMUM 1-3/8" THICK SOLID-CARE WOOD, 1-3/8'' STEEL HONEYCOMB DOOR, OR 20-MINUTE FIRE RATED DOOR EQUIPPED WITH A SELF-CLOSING AND SELF- LATCHING DEVICE PER CRC R302.5.1 ½-INCH GYPSUM BOARD FROM FOUNDATION TO ROOF SHEATHING ON THE GARAGE SIDE AT SEPARATION WALL BETWEEN GARAGE AND RESIDENCE SHALL BE PROVIDED PER CRC R302.6 AND TABLE R302.6 A-03.01BA-03.01BA-03.01 A A-03.01 A D/WMAX. RISE=7 3/4" NOSING=0.75" MAX. RISE=7 3/4" NOSING=0.75" MAX. RISE=7 3/4" NOSING=0.75" TANKLESS WATER HEATER 6' ABOVE A GARAGE FLOOR UNCOVERED PORCH (PA VED A REA) 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. PROJECT ID: DATE: SCALE: DRAWN BY: REVISION TABLE: NEW CONSTRUCTION WALL LEGEND: AMS DESIGN DESIGN Azadeh Masrour REVISION DATE BY DEP A -01.01 PROPOSED FLOOR PLAN 1/4'' = 1' BENEDICT RESIDENCE 15602 BENEDICT LN., LOS GATOS, CA 95032 1- BASEMENTS (EXCEPT THOSE ONLY FOR MECHANICAL EQUIPMENT AND NOT OVER 200 SQFT IN FLOOR AREA), HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. R310.1 a.MIN. NET CLEAR OPENABLE DIMENSION OF 24 INCHES IN HEIGHT. R310.1.2 b.MIN. NET CLEAR OPENABLE DIMENSION 20 INCHES IN WIDTH. R310.1.3 c.MIN. NET CLEAR OPENABLE DIMENSION OF 5.7 SQFT IN AREA. GRADE FLOOR OPENINGS SHALL HAVE A MIN. NET CLEAR OPENING OF 5 SQFT. 310.1.1 d.THE HEIGHT OF BOTTOM OF EMERGENCY EGRESS OPENING SHALL HAVE NOT MORE THAN 44 INCHES MEASURED FROM THE FLOOR. 310.2.2 2- FOR KITCHEN, A CLEAR PASSAGEWAY OF NOT LESS THAN 3-FEET BETWEEN THE COUNTER FRONTS AND APPLIANCES OR COUNTER FRONTS AND WALLS. CRC R311 3- SHOWER COMPARTMENTS AND WALL ABOVE BATHTUBES WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO THE HEIGHT NOT LESS THAN 72 INCHES(6 FT). CRC R307.2 4- THE DOOR BETWEEN GARAGE AND ENTRY REQUIRED TO BE SELF LATCHING AND SELF CLOSING, SOLID CORE DOOR NOT LESS THAN 1-3/8 INCH THICK. 5- THE MAXIMUM RISER HEIGHT CAN BE 7.75-INCHES. MINIMUM TREAD DEPTH CAN BE 10-INCHES. FOR ANY TREAD DEPTH LESS THAN 11- INCHES, A NOSING OF NOT LESS THAN 0.75-INCHES, BUT NOT MORE THAN 1.25-INCHES SHALL BE PROVIDED. 6- DOORS AND PANELS OF SHOWER AND BATHTUB ENCLOSURES SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CRC R308.6.2 GLAZING IN SHOWERS OR BATHTUB ADJACENT WALL OPENINGS WITHIN 60 INCHES ABOVE A STANDING SURFACE AND DRAIN INLET SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CRC R308.5 7- GLAZING IN AN INDIVIDUAL FIXED OR PORTABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF GLAZING IS LESS THAN 60-INCHES ABOVE THE WALKING SURFACE SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC ( I.E. SIDE LIGHT AT NEW MAIN ENTRY DOOR) . CRC R308.4.2 8- MINIMUM 36" DEEP LANDING IN THE DIRECTION OF TRAVEL AT NEW EXTERIOR DOORS SHALL BE PROVIDED. LANDING TO BE NOT MORE THAN 7-¾ INCHES LOWER THAN THE DOOR'S THRESHOLD FOR IN-SWINGING AND SLIDING GLASS DOORS AND NOT MORE THAN 7" FOR IN- SWINGING AND MAIN ENTRY DOOR. 9- NEW ENTRY DOOR SHALL BE OPENABLE FROM THE INSIDE OF THE DWELLING WITHOUT USE OF KEY, SPECIAL KNOWLEDGE OR EFFORT. CRC SEC. R311.2 10- 1/2" GYPSUM BOARD FROM FOUNDATION TO ROOF SHEATHING TO BE INSTALLED ON THE GARAGE SIDE AT SEPARATION WALL BETWEEN GARAGE AND RESIDENCE. (GARAGE MUST BE SEPARATED FROM THE DWELLING AND ITS ATTIC AREA) CRC SEC. R302.6 AND TABLE R302.6 5/8" TYPE "X" GYP. BOARD FINISH ON THE GARAGE SIDE OF THE WALL IS REQUIRED. ALSO THE GARAGE SHALL BE SEPRATED FROM THE DWELLING SPACE ABOVE, BY 5/8'' TYPE ''X'' GYP AT THE CEILING. 11- BATHROOMS & KITCHEN: 11.1- 22" MIN SHOWER DOOR CLEARANCE. 11.2- TEMPER GLAZING FOR THE SHOWER DOOR AND SLIDING WINDOWS. CEMENT BOARD SUBSTRATE FOR SHOWER WALLS. 11.3- LAVATORY FAUCETS TO HAVE A FLOW RATE OF NO MORE THAN 1.2 GPM OR LESS AT 60 PSI AND NOT LESS THAN 0.8 GPM OR LESS AT 20 PSI. (CALGREEN 4.303.1) 11.4- WATER CLOSETS TO HAVE A FLOW RATE OF 1.28 GALLONS/FLUSH OR LESS. (CALGREEN 4.303.1) 11.5 -CEMENT BOARD SUBSTRATE (IE. DUROCK OR WONDERBOARD,ETC) FOR TILE APPLICATION SURROUNDING THE BATH TUB WALLS . 11.6- KITCHEN FAUCETS TO HAVE A FLOW RATE OF 1.8 GPM OR LESS AT 60 PSI. (CALGREEN 4.303.1) 11.7- SHOWER HEAD TO HAVE A FLOW RATE NOT TO EXCEED OF 1.8 GPM AT 80 PSI. (CALGREEN 4.303.1) BUILDING NOTES: JAN.2022 S.A.PLN01 ---- SEP.2021 S.A. NORTH 1.PERMITS REQUIRED: A DEMOLITION PERMIT IS REQUIRED FOR THE DEMOLITION OF THE EXISTING SINGLE-FAMILY RESIDENCE AND DETACHED GARAGE. A SEPARATE BUILDING PERMIT IS REQUIRED FOR THE CONSTRUCTION OF THE NEW SINGLE-FAMILY RESIDENCE AND ATTACHED GARAGE. AN ADDITIONAL BUILDING PERMIT WILL BE REQUIRED FOR THE PV SYSTEM IF THE SYSTEM IS REQUIRED BY THE CALIFORNIA ENERGY CODE. 2.APPLICABLE CODES: THE CURRENT CODES, AS AMENDED AND ADOPTED BY THE TOWN OF LOS GATOS AS OF JANUARY 1, 2020, ARE THE 2019 CALIFORNIA BUILDING STANDARDS CODE, CALIFORNIA CODE OF REGULATIONS TITLE 24, PARTS 1-12, INCLUDING LOCALLY ADOPTED ENERGY REACH CODES. 3. CONDITIONS OF APPROVAL: THE CONDITIONS OF APPROVAL MUST BE BLUE LINED IN FULL ON THE COVER SHEET OF THE CONSTRUCTION PLANS. A COMPLIANCE MEMORANDUM SHALL BE PREPARED AND SUBMITTED WITH THE BUILDING PERMIT APPLICATION DETAILING HOW THE CONDITIONS OF APPROVAL WILL BE ADDRESSED. 4. BUILDING & SUITE NUMBERS: SUBMIT REQUESTS FOR NEW BUILDING ADDRESSES TO THE BUILDING DIVISION PRIOR TO SUBMITTING FOR THE BUILDING PERMIT APPLICATION PROCESS. 5. SIZE OF PLANS: MINIMUM SIZE 24” X 36”, MAXIMUM SIZE 30” X 42”. 6. REQUIREMENTS FOR COMPLETE DEMOLITION OF STRUCTURE: OBTAIN A BUILDING DEPARTMENT DEMOLITION APPLICATION AND A BAY AREA AIR QUALITY MANAGEMENT DISTRICT APPLICATION FROM THE BUILDING DEPARTMENT SERVICE COUNTER. ONCE THE DEMOLITION FORM HAS BEEN COMPLETED, ALL SIGNATURES OBTAINED, AND WRITTEN VERIFICATION FROM PG&E THAT ALL UTILITIES HAVE BEEN DISCONNECTED, RETURN THE COMPLETED FORM TO THE BUILDING DEPARTMENT SERVICE COUNTER WITH THE AIR DISTRICT’S J# CERTIFICATE, PG&E VERIFICATION, AND THREE (3) SETS OF SITE PLANS SHOWING ALL EXISTING STRUCTURES, EXISTING UTILITY SERVICE LINES SUCH AS WATER, SEWER, AND PG&E. NO DEMOLITION WORK SHALL BE DONE WITHOUT FIRST OBTAINING A PERMIT FROM THE TOWN. 7. SOILS REPORT: A SOILS REPORT, PREPARED TO THE SATISFACTION OF THE BUILDING OFFICIAL, CONTAINING FOUNDATION AND RETAINING WALL DESIGN RECOMMENDATIONS, SHALL BE SUBMITTED WITH THE BUILDING PERMIT APPLICATION. THIS REPORT SHALL BE PREPARED BY A LICENSED CIVIL ENGINEER SPECIALIZING IN SOILS MECHANICS. 8. SHORING: SHORING PLANS AND CALCULATIONS WILL BE REQUIRED FOR ALL EXCAVATIONS WHICH EXCEED FIVE (5) FEET IN DEPTH OR WHICH REMOVE LATERAL SUPPORT FROM ANY EXISTING BUILDING, ADJACENT PROPERTY, OR THE PUBLIC RIGHT-OF-WAY. SHORING PLANS AND CALCULATIONS SHALL BE PREPARED BY A CALIFORNIA LICENSED ENGINEER AND SHALL CONFIRM TO THE CAL/OSHA REGULATIONS. 9. FOUNDATION INSPECTIONS: A PAD CERTIFICATE PREPARED BY A LICENSED CIVIL ENGINEER OR LAND SURVEYOR SHALL BE SUBMITTED TO THE PROJECT BUILDING INSPECTOR AT FOUNDATION INSPECTION. THIS CERTIFICATE SHALL CERTIFY COMPLIANCE WITH THE RECOMMENDATIONS AS SPECIFIED IN THE SOILS REPORT, AND THAT THE BUILDING PAD ELEVATIONS AND ON-SITE RETAINING WALL LOCATIONS AND ELEVATIONS HAVE BEEN PREPARED ACCORDING TO THE APPROVED PLANS. HORIZONTAL AND VERTICAL CONTROLS SHALL BE SET AND CERTIFIED BY A LICENSED SURVEYOR OR REGISTERED CIVIL ENGINEER FOR THE FOLLOWING ITEMS: A. BUILDING PAD ELEVATION B. FINISH FLOOR ELEVATION C. FOUNDATION CORNER LOCATIONS D. RETAINING WALL(S) LOCATIONS AND ELEVATIONS 10. TITLE 24 ENERGY COMPLIANCE: ALL REQUIRED CALIFORNIA TITLE 24 ENERGY COMPLIANCE FORMS MUST BE BLUE-LINED (STICKY-BACKED), I.E. DIRECTLY PRINTED, ONTO A PLAN SHEET. 11. TOWN RESIDENTIAL ACCESSIBILITY STANDARDS: NEW RESIDENTIAL UNITS SHALL BE DESIGNED WITH ADAPTABILITY FEATURES FOR SINGLE-FAMILY RESIDENCES PER TOWN RESOLUTION 1994-61: A. WOOD BACKING (2” X 8” MINIMUM) SHALL BE PROVIDED IN ALL BATHROOM WALLS, AT WATER CLOSETS, SHOWERS, AND BATHTUBS, LOCATED 34 INCHES FROM THE FLOOR TO THE CENTER OF THE BACKING, SUITABLE FOR THE INSTALLATION OF GRAB BARS IF NEEDED IN THE FUTURE. B. ALL PASSAGE DOORS SHALL BE AT LEAST 32-INCH WIDE DOORS ON THE ACCESSIBLE FLOOR LEVEL. C. THE PRIMARY ENTRANCE DOOR SHALL BE A 36-INCH-WIDE DOOR INCLUDING A 5’X 5’ LEVEL LANDING, NO MORE THAN 1 INCH OUT OF PLANE WITH THE IMMEDIATE INTERIOR FLOOR LEVEL AND WITH AN 18-INCH CLEARANCE AT INTERIOR STRIKE EDGE. D. A DOOR BUZZER, BELL OR CHIME SHALL BE HARD WIRED AT PRIMARY ENTRANCE. 12. BACKWATER VALVE: THE SCOPE OF THIS PROJECT MAY REQUIRE THE INSTALLATION OF A SANITARY SEWER BACKWATER VALVE PER TOWN ORDINANCE 6.50.025. PLEASE PROVIDE INFORMATION ON THE PLANS IF A BACKWATER VALVE IS REQUIRED AND THE LOCATION OF THE INSTALLATION. THE TOWN OF LOS GATOS ORDINANCE AND WEST VALLEY SANITATION DISTRICT (WVSD) REQUIRES BACKWATER VALVES ON DRAINAGE PIPING SERVING FIXTURES THAT HAVE FLOOD LEVEL RIMS LESS THAN 12 INCHES ABOVE THE ELEVATION OF THE NEXT UPSTREAM MANHOLE. 13. HAZARDOUS FIRE ZONE: ALL PROJECTS IN THE TOWN OF LOS GATOS REQUIRE CLASS A ROOF ASSEMBLIES. 14. SPECIAL INSPECTIONS: WHEN A SPECIAL INSPECTION IS REQUIRED BY CBC SECTION 1704, THE ARCHITECT OR ENGINEER OF RECORD SHALL PREPARE AN INSPECTION PROGRAM THAT SHALL BE SUBMITTED TO THE BUILDING OFFICIAL FOR APPROVAL PRIOR TO ISSUANCE OF THE BUILDING PERMIT. THE TOWN SPECIAL INSPECTION FORM MUST BE COMPLETELY FILLED-OUT AND SIGNED BY ALL REQUESTED PARTIES PRIOR TO PERMIT ISSUANCE. SPECIAL INSPECTION FORMS ARE AVAILABLE FROM THE BUILDING DIVISION SERVICE COUNTER OR ONLINE AT WWW.LOSGATOSCA.GOV/BUILDING. 15. BLUEPRINT FOR A CLEAN BAY SHEET: THE TOWN STANDARD SANTA CLARA VALLEY NONPOINT SOURCE POLLUTION CONTROL PROGRAM SHEET (PAGE SIZE SAME AS SUBMITTED DRAWINGS) SHALL BE PART OF THE PLAN SUBMITTAL AS THE SECOND PAGE. THE SPECIFICATION SHEET IS AVAILABLE AT THE BUILDING DIVISION SERVICE COUNTER FOR A FEE OF $2 OR AT ARC BLUEPRINT FOR A FEE OR ONLINE AT WWW.LOSGATOSCA.GOV/BUILDING. 16. APPROVALS REQUIRED: THE PROJECT REQUIRES THE FOLLOWING DEPARTMENTS AND AGENCIES APPROVAL BEFORE ISSUING A BUILDING PERMIT: A. COMMUNITY DEVELOPMENT – PLANNING DIVISION: (408) 354-6874 B. ENGINEERING/PARKS & PUBLIC WORKS DEPARTMENT: (408) 399-5771 C. SANTA CLARA COUNTY FIRE DEPARTMENT: (408) 378-4010 D. WEST VALLEY SANITATION DISTRICT: (408) 378-2407 E. LOCAL SCHOOL DISTRICT: THE TOWN WILL FORWARD THE PAPERWORK TO THE APPROPRIATE SCHOOL DISTRICT(S) FOR PROCESSING. A COPY OF THE PAID RECEIPT IS REQUIRED PRIOR TO PERMIT ISSUANCE. DRAFT BUILDING CONDITIONS: SMA PROPOSED FRONT (NORTH-WEST) ELEVATION SC : 1/4" = 1'-0" 1 PROPOSED REAR (SOUTH-EAST) ELEVATION SC : 1/4" = 1'-0" 2 ALL PROJECTS IN THE TOWN OF LOS GATOS REQUIRE CLASS A ROOF ASSEMBLIES. 16080 4690 10050 6080Electrical Meter 16080 4690 10050 6080Electrical Meter Outdoor Compressor Unit 1 1/2 12 1 1/2 12 10'-0"17'-0"15'-8"1'-4"3'-0"2'-0"11'-10"EXISTING NATURAL GRADE LINE F.F. 15'-8" TOP HT. ABOVE F.F. 16'' ABOVE NATURAL GRADE 10'-0'' PLATE HT. ABOVE F.F. METAL STANDING SEAM MIN. FIRE RATING OF CLASS "A" ROOFING STUCCO THE LANDING SHALL NOT BE MORE THAN 7.75'' BELOW THE TOP OF THE THRESHOLD. WOOD SIDING WOOD STONE STUCCO 15602 NEW AND EXISTING BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. THESE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, ADDRESS NUMBERS SHALL BE PROVIDED IN ADDITIONAL APPROVED LOCATIONS TO FACILITATE EMERGENCY RESPONSE. ADDRESS NUMBERS SHALL BE ARABIC NUMBERS OR ALPHABETICAL LETTERS. NUMBERS SHALL BE A MINIMUM OF 4 INCHES (101.6 MM) HIGH WITH A MINIMUM STROKE WIDTH OF 0.5 INCH (12.7 MM). WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. ADDRESS NUMBERS SHALL BE MAINTAINED. CFC SEC. 505.1. METAL 16080 4690 10050 6080Electrical Meter 16080 4690 10050 6080Electrical Meter Outdoor Compressor Unit 10080 50802008050802880 Electrical Meter1008050802008050802880Electrical Meter Outdoor Compressor Unit 1 1/2 12 1 1/2 12 10'-0"17'-0"15'-8"1'-4"EXISTING NATURAL GRADE LINE F.F. 15'-8" TOP HT. ABOVE F.F. 16'' ABOVE NATURAL GRADE 10'-0'' PLATE HT. ABOVE F.F. STONE STONE THE LANDING SHALL NOT BE MORE THAN 7.75'' BELOW THE TOP OF THE THRESHOLD. METAL STANDING SEAM MIN. FIRE RATING OF CLASS "A" ROOFING STUCCO 10080 50802008050802880 Electrical Meter1008050802008050802880Electrical Meter Outdoor Compressor Unit 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. PROJECT ID: DATE: SCALE: DRAWN BY: REVISION TABLE: AMS DESIGN DESIGN Azadeh Masrour REVISION DATE BY DEP A -02.01 PROPOSED ELEVATIONS 1/4'' = 1' BENEDICT RESIDENCE 15602 BENEDICT LN., LOS GATOS, CA 95032 JAN.2022 S.A.PLN01 ---- SEP.2021 S.A. SMA PROPOSED RIGHT (SOUTH-WEST) ELEVATION SC : 1/4" = 1'-0" 1 PROPOSED LEFT (NORTH-EAST) ELEVATION SC : 1/4" = 1'-0" 2 ALL PROJECTS IN THE TOWN OF LOS GATOS REQUIRE CLASS A ROOF ASSEMBLIES. 2660 2620 3080 2660 3080 2660 2620 2660 10'-0"17'-0"15'-8"1'-4"EXISTING NATURAL GRADE LINE F.F. 15'-8" TOP HT. ABOVE F.F. 16'' ABOVE NATURAL GRADE 10'-0'' PLATE HT. ABOVE F.F. METAL STANDING SEAM MIN. FIRE RATING OF CLASS "A" ROOFING WOOD STONE STUCCO THE LANDING SHALL NOT BE MORE THAN 7.75'' BELOW THE TOP OF THE THRESHOLD. 2660 2620 3080 2660 3080 2660 2620 2660 30503050 2660 2620 2630 3050 Electrical Meter 2660 3050 Electrical Meter Outdoor Compressor Unit 10'-0"17'-0"15'-8"1'-4"5'-0"3'-0"3'-0"EXISTING NATURAL GRADE LINE F.F. 15'-8" TOP HT. ABOVE F.F. 16'' ABOVE NATURAL GRADE 10'-0'' PLATE HT. ABOVE F.F. METAL STANDING SEAM MIN. FIRE RATING OF CLASS "A" ROOFING STUCCO WOOD STONE THE LANDING SHALL NOT BE MORE THAN 7.75'' BELOW THE TOP OF THE THRESHOLD. 30503050 2660 2620 2630 3050 Electrical Meter 2660 3050 Electrical Meter Outdoor Compressor Unit 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. PROJECT ID: DATE: SCALE: DRAWN BY: REVISION TABLE: AMS DESIGN DESIGN Azadeh Masrour REVISION DATE BY DEP A -02.02 PROPOSED ELEVATIONS 1/4'' = 1' BENEDICT RESIDENCE 15602 BENEDICT LN., LOS GATOS, CA 95032 JAN.2022 S.A.PLN01 ---- SEP.2021 S.A. SMA A-A CROSS SECTION SC : 1/4" = 1'-0" 1 B-B CROSS SECTION SC : 1/4" = 1'-0" 2 15588 BENEDICT LN. 15625 BENEDICT LN. 15602 BENEDICT LN. 15603 BENEDICT LN. 15624 BENEDICT LN. 15589 BENEDICT LN. 1 1/2 12 1 1/2 12 10'-0"17'-0"15'-8"1'-4"4'-7"2'-1"10'-0"1'-6"28802880 3690 EXISTING NATURAL GRADE LINE F.F. 15'-8" TOP HT. ABOVE F.F. 16'' ABOVE NATURAL GRADE 10'-0'' PLATE HT. ABOVE F.F. STONE METAL STANDING SEAM MIN. FIRE RATING OF CLASS "A" ROOFING THE LANDING SHALL NOT BE MORE THAN 7.75'' BELOW THE TOP OF THE THRESHOLD. CRAWL SPACE MIN DIM.KITCHEN & FAMILY ATTIC ATTIC 4690 10'-0"17'-0"15'-8"1'-4"1'-6"10'-0"11'-0"0'-10"1'-1"EXISTING NATURAL GRADE LINE F.F. 15'-8" TOP HT. ABOVE F.F. 16'' ABOVE NATURAL GRADE 10'-0'' PLATE HT. ABOVE F.F. METAL STANDING SEAM MIN. FIRE RATING OF CLASS "A" ROOFING WOOD STONE THE LANDING SHALL NOT BE MORE THAN 7.75'' BELOW THE TOP OF THE THRESHOLD. CRAWL SPACE MIN DIM.BEDROOMBATHWALK-IN-CLOSET MINIMUM ROOF SLOPE SHALL BE 1/4 INCH PER FOOT, I.E. 1 UNIT VERTICAL IN 48 UNITS HORIZONTAL (2% SLOPE). CRC R905.4.2, R905.9.1, R905.11.1, R905.12.1, R905.13.1, R905.14.1, AND R905.15.1 GARAGE THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY(R309.1). CEILING OF THE PRIVATE GARAGE (ATTACHED OR LESS THAN 3' FROM DWELLING) SHALL BE SEPARATED FROM THE DWELLING UNIT ABOVE BY NOT LESS THAN A 5/8" TYPE X GYPSUM BOARD OR EQUIVALENT(T-R302.6) ½-INCH GYPSUM BOARD FROM FOUNDATION TO ROOF SHEATHING ON THE GARAGE SIDE AT SEPARATION WALL BETWEEN GARAGE AND RESIDENCE SHALL BE PROVIDED PER CRC R302.6 AND TABLE R302.6 TANKLESS WATER HEATER 6' ABOVE A GARAGE FLOOR ATTIC Electrical Meter Outdoor Compressor Unit 17'-0"16'-6"16'-10"Electrical Meter Outdoor Compressor Unit 15'-7"16'-0"24'-3"4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. PROJECT ID: DATE: SCALE: DRAWN BY: REVISION TABLE: AMS DESIGN DESIGN Azadeh Masrour REVISION DATE BY DEP A -03.01 PROPOSED SECTIONS / SCHEMATIC ELEVATIONS 1/4'' = 1' BENEDICT RESIDENCE 15602 BENEDICT LN., LOS GATOS, CA 95032 JAN.2022 S.A.PLN01 ---- SEP.2021 S.A. SMA FLOOR AREA DIAGRAM - EXISTING FLOOR PLAN SC : 1/8" = 1'-0" 1 FLOOR AREA DIAGRAM - PROPOSED FLOOR PLAN SC : 1/8" = 1'-0" 2 D/WWH REF.27'-7" 12'-7"20'-7"14'-5"20'-0" 16'-3"15'-10"20'-5"8'-5"19'-11"24'-4" 16'-0" A B C D E E1 REF.54'-9"18'-4"38'-3"11'-2"34'-0"4'-3"11'-2" 20'-11"17'-5"20'-10"20'-11" 28'-5" 54'-9"8'-0"A B C D E F G D/W4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. PROJECT ID: DATE: SCALE: DRAWN BY: REVISION TABLE: AMS DESIGN DESIGN Azadeh Masrour REVISION DATE BY DEP BENEDICT RESIDENCE 15602 BENEDICT LN., LOS GATOS, CA 95032 JAN.2022 S.A.PLN01 ---- SEP.2021 S.A. FLOOR AREA DIAGRAM A -04.01 1/8'' = 1' 24'-4"X19'-11" E1 FLOORS SIZE 27'-7"X20'-7" AREAS (SQF)TOTAL 15'-10"X12'-7"B A 199 D 20'-0"X14'-5"288 E 485 568 SPACES 620 LIVING AREA GARAGE 16'-0"X8'-5"135 20'-5"X16'-3"C 332 1387 TOTAL BUILDING AREA 2007 11'-2"X4'-3" F FLOORS SIZE 54'-9"X18'-4" AREAS (SQF)TOTAL 38'-3"X28'-5"B A 1087 D 20'-11"X17'-5"364 E 47 1004 SPACES LIVING AREA GARAGE 20'-11"X20'-10"436 34'-0"X11'-2"C 380 2882 TOTAL BUILDING AREA 3318 436 54'-9"X8'-0"G 438 438UNCOVERED PORCH (PAVED AREA) SMA 15588 BENEDICT LN. 15625 BENEDICT LN. 15602 BENEDICT LN. 15603 BENEDICT LN. 15624 BENEDICT LN. 15589 BENEDICT LN.VICINITY GUIDE MAP 15624 15602 1558815589 15603 15625 4010 MOORPARK AVE#101, SAN JOSE, CA 95117 TELL: (415)254.1606 E-MAIL: OFFICE@AMSDESIGNLLP.COM PROJECT NAME: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SHEET NUMBER: SHEET TITLE: THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. PROJECT ID: DATE: SCALE: DRAWN BY: REVISION TABLE: AMS DESIGN DESIGN Azadeh Masrour REVISION DATE BY DEP BENEDICT RESIDENCE 15602 BENEDICT LN., LOS GATOS, CA 95032 JAN.2022 S.A.PLN01 ---- SEP.2021 S.A. EXTERIOR MATERIAL BOARD / STREET SCAPE ELEVATION A -05.01 N.T.S CLOPAY DOORS TYPE CLOPAY DARK GRAY COLOR ROOF DOOR DARK GRAY COLOR MI LGARDWINDOWS SMOOTH STUCCO METAL STA NDI NG SEAM TI TLE CREAM COLOR TUSCANY / DARK GRAY COLOR SIDING GARAGE DOOR I NFO STUCCO METAL STANDI NG SEAM EXTERIOR MATERIAL BOARD BLACK COLOR SMA City of FremontCityCity ofFremontCLEAN BAY BLUE PRINTClean Bay Blue Print