Staff Report with Exhibits. 465 N. Santa Cruz Avenue PREPARED BY: ERIN WALTERS Associate Planner Reviewed by: Planning Manager and Community Development Director 110 E. Main Street Los Gatos, CA 95030 ● (408) 354-6872 www.losgatosca.gov TOWN OF LOS GATOS PLANNING COMMISSION REPORT MEETING DATE: 06/08/2022 ITEM NO: 2 DATE: June 3, 2022 TO: Planning Commission FROM: Joel Paulson, Community Development Director SUBJECT: Requesting Approval of a Mixed-Use Project with One Dwelling Unit in an Existing Commercial Building, with Shared Parking on Property Zoned C-1. Located at 465 N. Santa Cruz Avenue. APN 410-16-004. Conditional use Permit Application U-22-001. PROPERTY OWNER: Jamie Pfister. APPLICANT: Marcie MacDonough. PROJECT PLANNER: Erin Walters. RECOMMENDATION: Consider approval of a mixed-use project with one dwelling unit in an existing commercial building, with shared parking on property zoned C-1, located at 465 N. Santa Cruz Avenue. PROJECT DATA: General Plan Designation: Neighborhood Commercial Zoning Designation: C-1 (Neighborhood Commercial) Applicable Plans & Standards: General Plan, Commercial Design Guidelines Parcel Size: 6,500 square feet Surrounding Area: Existing Land Use General Plan Zoning North Commercial Neighborhood Commercial C-1 South Commercial Neighborhood Commercial C-1 East Commercial Neighborhood Commercial C-1:PD West Single-Family Residential Medium Density Residential R-1D PAGE 2 OF 9 SUBJECT: 465 N. Santa Cruz Avenue/U-22-001 DATE: June 3, 2022 S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Staff Report. 465 N. Santa Cruz Avenue.docx CEQA: The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15301: Existing Facilities. FINDINGS: ▪ The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15301: Existing Facilities. ▪ As required by Section 29.20.190 (a) of the Town Code for granting a Conditional Use Permit. ▪ As required by Section 29.10.150 (b) of the Town Code for granting less visitor parking. ▪ As required by Section 29.10.150(e) of the Town Code for granting a Shared Parking Agreement. ACTION: The decision of the Planning Commission is final unless appealed within ten days. BACKGROUND: The proposed mixed-use project would occupy an existing commercial building, that was formerly occupied by a retail use, a personal service use, a vacuum repair shop, and a nail salon. PROJECT DESCRIPTION: A. Location and Surrounding Neighborhood The subject property is located on the west side of N. Santa Cruz Avenue, approximately 240 feet south of the intersection with Andrews Street (Exhibit 1). The property is surrounded by commercial uses to the north, east, and south, and single-family residential uses are located to the west directly behind the subject property. B. Conditional Use Permit The applicant is requesting approval of a Conditional Use Permit (CUP) for a commercial mixed-use project with one dwelling unit in an existing commercial building. The proposed exterior alterations to the building will be reviewed for conformance with the Commercial Design Guidelines as part of a future building permit. Any signage will be reviewed through a future sign application. PAGE 3 OF 9 SUBJECT: 465 N. Santa Cruz Avenue/U-22-001 DATE: June 3, 2022 S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Staff Report. 465 N. Santa Cruz Avenue.docx PROJECT DESCRIPTION (continued): When reviewing a CUP, the deciding body should consider the information in the applicant’s business plan; however, the key consideration should be the proposed use since the business plan can change from owner to owner. The CUP runs with the land, and the deciding body should review the application based on the use described in the recommended Conditions of Approval (Exhibit 3) as opposed to the applicant’s business plan. C. Zoning Compliance The zoning designation allows a mixed-use project with residential subject to the approval of a CUP. The proposed project is on a site with existing non-conforming parking, and requests: a Shared Parking Agreement between the two proposed uses; a request for the reduction of one residential guest parking space; and proposes to pay parking in-lieu fees per Town Code to remedy the existing non-conforming parking situation. DISCUSSION: A. Project Summary The proposed mixed-use project would occupy an existing 2,430-square foot commercial building. The project proposes to reconfigure the existing commercial building into a 1,941- square foot office and a 489-square foot residential studio apartment located at the rear of the building. The project proposes removal of an existing carport and storage area located to the rear of the existing building. The proposed hours of operation for the office use are 9:00 a.m. to 5:00 p.m., Monday through Friday. The applicant provided a written description and letter of justification (Exhibit 4), materials and colors board (Exhibit 6), and development plans (Exhibit 7). Hours of operation are included in the recommended Conditions of Approval (Exhibit 3). B. Parking Existing Parking The existing site provides a total of six parking spaces and per Town Code the existing commercial use requires a total of nine on-site parking spaces. The site is therefore non- conforming for parking. The parking analysis on the following page summarizes the total number of required parking spaces per Town Code based on existing uses. PAGE 4 OF 9 SUBJECT: 465 N. Santa Cruz Avenue/U-22-001 DATE: June 3, 2022 S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Staff Report. 465 N. Santa Cruz Avenue.docx DISCUSSION (continued): Existing On-Site Parking Use Square Feet Downtown Parking Ratio Required Spaces Commercial 2,430 1/300 8.1 = 9 Total required: 9 spaces Provided: 6 spaces Deficit: -3 spaces Proposed Parking The proposed mixed-use project requires a total of eight on-site parking spaces pursuant to Town Code if less guest parking is allowed and a Shared Parking Agreement is approved. The proposed project provides a total of five on-site parking spaces as a result of complying with the requirement to convert one of the existing parking spaces to an accessible ADA space. Pursuant to Town Code the applicant is given credit for a total of six on-site spaces because of this requirement. The existing site is constrained and unable to accommodate additional on-site parking spaces. The parking analysis below summarizes the total number of required on-site parking spaces per Town Code based on proposed uses if less guest parking is allowed and a Shared Parking Agreement is approved. Proposed On-Site Parking Use Square Feet Downtown Parking Ratio Required Spaces Office 1,941 1/250 7.8 Multi-Family (1 - Apt Studio) 1.5 Guest Multi-Family 1 Zero guest parking request -1 Shared Parking Agreement -1.5 Total required: 7.8 = 8 spaces Provided: 5 = 6 (ADA credit) Deficit: -2 spaces In order to meet the required parking requirements per Town Code, the project proposes the use of three different sections of Town Code to address the on-site parking deficiencies for the proposed uses and site constraints: 1. A request for the reduction of one residential guest parking space; 2. A Shared Parking Agreement between the office and residential use; and PAGE 5 OF 9 SUBJECT: 465 N. Santa Cruz Avenue/U-22-001 DATE: June 3, 2022 S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Staff Report. 465 N. Santa Cruz Avenue.docx DISCUSSION (continued): 3. Payment of a parking in-lieu fee for the two deficient parking spaces. Residential Guest Space The applicant requests a reduction in the guest parking requirement (-1 space) for the residential studio apartment from Planning Commission. Pursuant to Town Code Section 29.10.150. Number of off-street spaces required: (b) Parking requirements for downtown. In addition to other parking requirements, one visitor parking space for each residential unit other than detached single-family or two- family dwelling shall be required unless the Planning Commission makes a finding that more or less visitor parking is necessary due to the size or type of housing unit(s). The applicant has provided justification requesting that the Planning Commission allow a reduction in guest parking as the site currently has non-conforming parking, the site is constrained, and parking has been provided to the maximum extent possible. The applicant states that the proposed mixed-use project will not make the parking burden worse as they are proposing to utilize a Shared Parking Agreement between the residential and office uses on site. In addition, the applicant states the project’s location provides a walkable neighborhood and access to public transportation (Exhibit 4). Shared Parking Agreement Pursuant to Town Code Section 29.10.150. Number of off-street spaces required: (e) Shared Parking. Where uses are required by this division to be served by off-street parking spaces, and where some of the uses generate parking demands primarily during hours when the remaining uses are closed, shared parking is allowed, but only if specifically authorized by the Community Development Director. Issuance of a shared parking permit must be supported by findings that the shared parking spaces will not result in the effective provisions of fewer off-street parking spaces than required by this division. The permit may contain such conditions as are necessary to assure the facts found will continue to exist, including: (1) Submission of satisfactory statements by the party or parties providing the proposed shared parking, describing the users and their times of operation where applicable, and showing the absence of conflict between them; (2) Written agreements between the parties setting forth the terms and conditions under which the shared parking spaces will be operated including: location, number of spaces, and times of operation where applicable; PAGE 6 OF 9 SUBJECT: 465 N. Santa Cruz Avenue/U-22-001 DATE: June 3, 2022 S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Staff Report. 465 N. Santa Cruz Avenue.docx DISCUSSION (continued): (3) Documents showing maintenance provisions; and (4) Other documents or commitments deemed necessary. Whenever shared parking spaces are authorized to serve multiple uses, the number of spaces required shall be based upon the use which generates the largest number required. The applicant has proposed the following shared parking hours: Proposed Shared Parking Agreement Hours Office 9:00 a.m. to 5:00 p.m. - Monday through Friday Residential Dwelling Unit 5:00 p.m. to 9:00 a.m. - Monday through Friday 24 hours – Saturday and Sunday A Shared Parking Agreement will allow the office use to utilize the existing parking spaces during office hours and the residential use to utilize the parking spaces during non-office hour. (Condition of Approval #6, Exhibit 3). Parking In-Lieu Fee Pursuant to Town Code Section. 29.10.207. Effect of nonconforming use as to parking on commercial uses: (c) Notwithstanding subsection (b) above or section 29.10.215 below, a commercial use located between Los Gatos-Saratoga Road and Ashler Avenue with lot frontage on North Santa Cruz Avenue or the northside of Los Gatos-Saratoga Road and west of State Highway 17 that is nonconforming as to parking may improve and remodel the interior or the exterior of an existing building that is occupied by the nonconforming commercial use if: (1) There is no increase in the floor area of the building; (2) There is no reduction in the number of parking spaces provided for the use; and (3) The parking in lieu fee established by Council resolution is paid to the Town. However, the payment of the in-lieu fee under this subsection shall make the use conforming as to parking only for those improvements allowed under this subsection. The analysis on the following page summarizes the number of deficient parking spaces and required parking in-lieu fee per the total number of required parking spaces per Town Code based on the proposed uses. PAGE 7 OF 9 SUBJECT: 465 N. Santa Cruz Avenue/U-22-001 DATE: June 3, 2022 S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Staff Report. 465 N. Santa Cruz Avenue.docx DISCUSSION (continued): Parking In-Lieu Fee – Office Use Office Use Required Spaces 7.8 = 8 spaces Provided Spaces 5 = 6 (ADA credit) Deficit -2 spaces Parking In-Lieu Fee 2 spaces x $2,000 = $4,000 The proposed project does not propose an increase in existing floor area. The proposed project does not reduce the number of parking spaces provided for the use with the exception of the loss of one parking space due to ADA requirements. The applicant shall pay an in-lieu fee of $2,000 per deficient parking space for a total in -lieu fee of $4,000 (Condition #7, Exhibit 3). C. Conditional Use Permit Findings Pursuant to Town Code Section 29.20.190(a), in order to grant approval of a CUP, the deciding body must make the following findings: (1) The proposed use of the property is essential or desirable to the public convenience or welfare; and (2) The proposed use would not impair the integrity and character of the zone; and (3) The proposed use would not be determinantal to public health, safety, or general welfare; and (4) The proposed use of the property is in harmony with the various elements or objectives of the General Plan and the purposes of the Town Code. In regards to finding one, the use is essential or desirable to the public convenience because it would provide a housing opportunity within an existing building that is within walking distance to Downtown and other amenities. In regards to the second finding, the proposed use would not impair the integrity of the zone, in that the proposed mixed-use project would be developed within an existing commercial building. In regards to the third finding, the proposed use would not be detrimental to public health, safety, or general welfare, as the conditions placed on the permit would maintain the welfare of the community. In regards to the final finding, the proposed use would be in conformance with the Town Code and General Plan as the mixed-use project would provide a new housing unit, the proposed use would reduce vehicle miles traveled as the site is located within walking distance to the Downtown and neighboring amenities, and the proposed office use would provide employment opportunities in the C-1 zone. PAGE 8 OF 9 SUBJECT: 465 N. Santa Cruz Avenue/U-22-001 DATE: June 3, 2022 S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Staff Report. 465 N. Santa Cruz Avenue.docx DISCUSSION (continued): D. Environmental Review The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15301: Existing Facilities. No significant effect on the environment will occur since the project uses an existing structure with no increase in floor area. PUBLIC COMMENTS: Written notice of the Planning Commission hearing was sent to property owners and tenants within 300 feet of the subject property. The applicant has reached out to the neighboring tenants and property owners and provided a summary (Exhibit 5). At the time of this report’s preparation, the Town has not received any public comment. CONCLUSION: A. Summary The project would allow a mixed-use project with one dwelling unit in an existing commercial building. The project meets all zoning regulations, if approved through a CUP, with the exception of parking. The project proposes the use of three different sections of Town Code to address the on-site parking deficiencies for the proposed uses and site constraints to meet the parking requirements: • A request for the reduction of one residential guest parking space; • A Shared Parking Agreement between the office and residential use; and • Payment of a parking in-lieu fee for the two deficient parking spaces. The proposed project meets the objectives of the 2020 General Plan and will provide a mixed-use development with a new housing unit located within walking distance to the Downtown and neighboring amenities. B. Recommendation Based on the analysis above, staff recommends approval of the Conditional Use Permit subject to the recommended Conditions of Approval (Exhibit 3). If the Planning Commission finds merit with the proposed project, it should: 1. Make the finding that the proposed project is categorically exempt, pursuant to Section 15301 of the California Environmental Quality Act (Exhibit 2); PAGE 9 OF 9 SUBJECT: 465 N. Santa Cruz Avenue/U-22-001 DATE: June 3, 2022 S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Staff Report. 465 N. Santa Cruz Avenue.docx CONCLUSION (continued): 2. Make the required findings as required by Section 29.20.190 (a) of the Town Code for granting approval of a CUP (Exhibit 2); 3. Make the required findings as required by Section 29.10.150 (b) of the Town Code for granting less visitor parking (Exhibit 2); 4. Make the required findings as required by Section 29.10.150 (e) of the Town Code for granting a Shared Parking Agreement (Exhibit 2); 5. Approve CUP Application U-22-001 with the conditions contained in Exhibit 3, and the plans in Exhibit 7. C. Alternatives Alternatively, the Commission can: 1. Continue the matter to a date certain with specific direction; 2. Approve the application with additional and/or modified conditions; or 3. Deny the application. EXHIBITS: 1. Location Map 2. Required Findings 3. Recommended Conditions of Approval 4. Written Description and Letter of Justification 5. Applicant’s Neighborhood Outreach 6. Materials and Colors Board 7. Development Plans This Page Intentionally Left Blank ANDRE W S S T MONTEREY AVN SANTA CRUZ AVUNIVERSITY AVSAN BENITO AVINDUSTRIAL WYCHESTER S T 465 N Santa Cruz Avenue 0 0.250.125 Miles ° Update Notes:- Updated 12/20/17 to link to tlg-sql12 server data (sm)- Updated 11/22/19 adding centerpoint guides, Buildings layer, and Project Site leader with label- Updated 10/8/20 to add street centerlines which can be useful in the hillside area- Updated 02-19-21 to link to TLG-SQL17 database (sm) ATTACHMENT 1 This Page Intentionally Left Blank S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Exhibit 2 - Findings and Considerations.docx PLANNING COMMISSION – June 8, 2022 REQUIRED FINDINGS FOR: 465 N. Santa Cruz Avenue Conditional Use Permit U-22-001 Requesting Approval of a Mixed-Use Project with One Dwelling Unit in an Existing Commercial Building, with Shared Parking on Property Zoned C-1. APN 410-16-004. PROPERTY OWNER: Jamie Pfister APPLICANT: Marcie MacDonough FINDINGS Required finding for CEQA: ■ The project is Categorically Exempt pursuant to Section 15301 of the State Environmental Guidelines as adopted by the Town. No significant effect on the environment will occur since the project uses an existing structure with no increase in floor area. Required findings for a Conditional Use Permit: ■ As required by Section 29.20.190 (a) of the Town Code for granting a Conditional Use Permit: The deciding body, on the basis of the evidence submitted at the hearing, may grant a conditional use permit when specifically authorized by the provisions of this chapter if it finds that: 1. The proposed use is essential and desirable to the public convenience because it would provide a housing opportunity within an existing commercial building that is within walking distance to Downtown and other amenities; and 2. The proposed use would not impair the integrity of the zone, in that the proposed mixed- use project would be developed within an existing commercial building; and 3. The proposed use would not be detrimental to public health, safety, or general welfare, as the conditions placed on the permit and existing regulations would maintain the welfare of the community; and 4. The proposed use is in conformance with the Town Code and General Plan as the mixed-use project would provide a new housing unit, the proposed use would reduce vehicle miles traveled as the site is located within walking distance to the Downtown and amenities, and the proposed office use would provide employment opportunities in the C-1 zone. Required findings for a Granting Less Visitor Parking: ■ As required by Section 29.10.150 (b) of the Town Code for granting less visitor parking: The Planning Commission, may make the finding that less visitor parking is necessary due to the size or type of housing unit(s). EXHIBIT 2 The proposed mixed-use project will not make the parking burden worse as they are proposing to utilize a Shared Parking Agreement between the residential and office uses on site. Required findings for a granting a Shared Parking Agreement: ■ As required by Section 29.10.150 (e) of the Town Code for granting a Shared Parking Agreement: Where uses are required by this division to be served by off-street parking spaces, and where some of the uses generate parking demands primarily during hours when the remaining uses are closed, shared parking is allowed, but only if specifically authorized by the Community Development Director. Issuance of a shared parking permit must be supported by findings that the shared parking spaces will not result in the effective provisions of fewer off-street parking spaces than required by this division. The permit may contain such conditions as are necessary to assure the facts found will continue to exist, including: (1) Submission of satisfactory statements by the party or parties providing the proposed shared parking, describing the users and their times of operation where applicable, and showing the absence of conflict between them; (2) Written agreements between the parties setting forth the terms and conditions under which the shared parking spaces will be operated including: location, number of spaces, and times of operation where applicable; (3) Documents showing maintenance provisions; and (4) Other documents or commitments deemed necessary. Whenever shared parking spaces are authorized to serve multiple uses, the number of spaces required shall be based upon the use which generates the largest number required. The applicant has proposed the following shared parking hours: Proposed Shared Parking Agreement Hours Office 9:00 a.m. to 5:00 p.m. - Monday through Friday Residential Dwelling Unit 5:00 p.m. to 9:00 a.m. - Monday through Friday 24 hours - Saturday and Sunday A Shared Parking Agreement will allow the office use to utilize the existing parking spaces during office hours and the residential use to utilize the parking spaces during non-office hours (Condition of Approval #6, Exhibit 3). S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Exhibit 3 - Recommended Conditions of Approval.docx PLANNING COMMISSION – June 8, 2022 CONDITIONS OF APPROVAL 465 N. Santa Cruz Avenue Conditional Use Permit U-22-001 Requesting Approval of a Mixed-Use Project with One Dwelling Unit in an Existing Commercial Building, with Shared Parking on Property Zoned C-1. APN 410-16-004. PROPERTY OWNER: Jamie Pfister APPLICANT: Marcie MacDonough TO THE SATISFACTION OF THE DIRECTOR OF COMMUNITY DEVELOPMENT: Planning Division 1. APPROVAL: This application shall be completed in accordance with all of the conditions of approval and in substantial compliance with the approved plans. Any intensification beyond this authorized use requires a Conditional Use Permit amendment. 2. EXPIRATION: The approval will expire two years from the approval date pursuant to Section 29.20.320 of the Town Code, unless the approval has been vested per Section 29.20.335 of the Town Code. Reasonable extensions of time not exceeding one year may be granted upon application, and can be granted if approved by the deciding body prior to the expiration date. Therefore, it is recommended that applications for a time ex tension be filed with the Community Development Department at least 60 days prior to the expiration date of the approval. 3. LAPSE FOR DISCONTINUANCE: If the activity for which the Conditional Use Permit has been granted is discontinued for a period of one (1) year, the approval lapses pursuant to Section 29.20.340 of the Zoning Ordinance. 4. USE: The approved use is for a mixed-use project with one residential dwelling unit. 5. HOURS OF OPERATION: The hours of non-residential operation shall be limited to the following: • 9:00 a.m. to 5:00 p.m., Monday through Friday 6. SHARED PARKING AGREEMENT: A Shared Parking Agreement shall be obtained and approved pursuant to Town Code prior the issuance of building permits. The Shared Parking Agreement hours are: • Non-Residential Parking Hours - 9:00 a.m. to 5:00 p.m. - Monday through Friday • Residential Parking Hours - 5:00 p.m. to 9:00 a.m. - Monday through Friday and 24 hours on Saturday and Sunday 7. PARKING FEE: The appropriate in-lieu parking fee for two spaces, $4,000.00, shall be paid to the Finance Department prior to issuance of building permits. 8. SIGN PERMIT: A Sign Permit from the Los Gatos Community Development Department must be obtained prior to any changes to existing signs or installation of new signs. 9. ROOFTOP EQUIPMENT: Any new or modified roof mounted equipment shall be fully screened prior to issuance of an occupancy permit. 10. OUTDOOR LIGHTING: Prior to final occupancy all exterior lighting shall be kept to a EXHIBIT 3 S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Exhibit 3 - Recommended Conditions of Approval.docx minimum and shall be down directed fixtures that will not reflect or encroach onto adjacent properties. All exterior lighting shall utilize shields so that no bulb is vis ible and to ensure that the light is directed to the ground surface and does not spill light onto neighboring parcels or produce glare when seen from nearby homes. No flood lights shall be used unless it can be demonstrated that they are needed for safety or security. 11. EXISTING TREES: All existing trees shown on the plan and trees required to remain or to be planted are specific subjects of approval of this plan and must remain on the site. 12. TREE FENCING: Protective tree fencing, and other protection measures shall be placed at the drip line of existing trees prior to issuance of demolition and building permits and shall remain through all phases of construction. Include a tree protection plan with the construction plans. 13. TREE REPLACEMENT: Prior to issuance of final occupancy replacement trees must be planted. 14. TREE STAKING: All newly planted trees shall be double-staked using rubber tree ties. 15. WATER EFFICIENCY LANDSCAPE ORDINANCE: The final landscape plan shall meet the requirements of the Town of Los Gatos Water Conservation Ordinance or the State Water Efficient Landscape Ordinance, whichever is more restrictive. Submittal of a Landscape Documentation Package pursuant to WELO is required prior to issuance of a building permit. A review fee based on the cu rrent fee schedule adopted by the Town Council is required when working landscape and irrigation plans are submitted for review. A completed WELO Certificate of Completion is required prior to final inspection/certificate of occupancy. 16. BUSINESS LICENSE: A business license from the Town of Los Gatos Finance Department including a Certificate of Use and Occupancy approval from Planning must be obtained prior to the commencement of any new or change of use. 17. CERTIFICATE OF USE AND OCCUPANCY: A Certificate of Use and Occupancy must be obtained prior to commencement of use. 18. CONFORMANCE WITH CODE: No part of this approval shall be construed to permit a violation of any part of the Code of the Town of Los Gatos. 19. COMPLIANCE WITH LOCAL, STATE, and FEDERAL LAWS: The subject use shall be conducted in full compliance with all local, state, and federal laws. 20. TOWN INDEMNITY: Applicants are notified that Town Code Section 1.10.115 requires that any applicant who receives a permit or entitlement from the Town shall defen d, indemnify, and hold harmless the Town and its officials in any action brought by a third party to overturn, set aside, or void the permit or entitlement. This requirement is a condition of approval of all such permits and entitlements whether or not ex pressly set forth in the approval, and may be secured to the satisfaction of the Town Attorney. 21. COMPLIANCE MEMORANDUM: A memorandum, in compliance with standard Town practice, shall be prepared and submitted with the building permit detailing how the conditions of approval will be addressed. S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Exhibit 3 - Recommended Conditions of Approval.docx Building Division 22. REVIEW: A comprehensive plan review has not been completed for this CUP modification under consideration by the Development Review Committee and compliance with applicable codes have not been verified. 23. PERMITS: No work requiring Building Permits can commence without issuance of any required Building Permits. Building Permit plan review, including review by the Santa Clara County Fire Department and the Parks and Public Works Department, will be part of any required Building Permit application process. No change in the character of occupancy or change to a different group of occupancies as described by the Building Code shall be made without first obtaining a Certificate of Occupancy from the Building Official. 24. ACCESSIBILITY: In addition to all new work complying with the Code for accessibility, when existing buildings are altered or remodeled, they must be made accessible to persons with physical disabilities in accordance with the CBC Section 11B -202, “Existing buildings and facilities”. TO THE SATISFACTION OF THE DIRECTOR OF PARKS AND PUBLIC WORKS: Engineering Division 25. GENERAL: All work shall conform to the applicable Town ordinances. The adjacent public right-of-way shall be kept clear of all job-related mud, silt, concrete, dirt and other construction debris at the end of the day. Dirt and debris shall not be washed into storm drainage facilities. The storing of goods and materials on the sidewalk and/or the street will not be allowed unless an encroachment permit is issued by the Engineering Division of the Parks and Public Works Department. The Owner and/or Applicant's representative in charge shall be at the job site during all working hours. Failure to maintain the public right-of-way according to this condition may result in the issuance of correction notices, citations, or stop work orders and the Town performing the required maintenance at the Owner and/or Applicant's expense. 26. APPROVAL: This application shall be completed in accordance with all the conditions of approval listed below and in substantial compliance with the latest reviewed and approved development plans. Any changes or modifications to the approved plans or conditions of approvals shall be approved by the Town Engineer. 27. RESTORATION OF PUBLIC IMPROVEMENTS: The Owner and/or Applicant or their representative shall repair or replace all existing improvements not designated for removal that are damaged or removed because of the Owner and/or Applicant or their representative's operations. Improvements such as, but not limited to: curbs, gutters, sidewalks, driveways, signs, pavements, thermoplastic pavement markings, etc., shall be repaired and replaced to a condition equal to or better than the original condition. Any new concrete shall be free of stamps, logos, names, graffiti, etc. Any concrete identified that is displaying a stamp or equal shall be removed and replaced at the Contractor’s sole expense and no additional compensation shall be allowed therefore. Existing improvement to be repaired or replaced shall be at the direction of the Engineering Construction Inspector and shall comply with all Title 24 Disabled Access provisions. The S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Exhibit 3 - Recommended Conditions of Approval.docx restoration of all improvements identified by the Engineering Construction Inspector shall be completed before the issuance of a certificate of occupancy. The Owner and/or Applicant or their representative shall request a walk-through with the Engineering Construction Inspector before the start of construction to verify existing conditions. 28. DESIGN CHANGES: Any proposed changes to the approved plans shall be subject to the approval of the Town prior to the commencement of any and all altered work. The Owner and/or Applicant’s project engineer shall notify, in writing, the Town Engineer at least seventy-two (72) hours in advance of all the proposed changes. Any approved changes shall be incorporated into the final “as-built” plans. 29. PLANS AND STUDIES: Any studies imposed by the Planning Commission or Town Council shall be funded by the Owner and/or Applicant. 30. CONSTRUCTION VEHICLE PARKING: Construction vehicle parking within the public right- of-way will only be allowed if it does not cause access or safety problems as determined by the Town. 31. CONSTRUCTION HOURS: All construction activities, including the delivery of construction materials, labors, heavy equipment, supplies, etc., shall be limited to the hours of 8:00 a.m. to 6:00 p.m., weekdays and 9:00 a.m. to 4:00 p.m. Saturdays, holidays excluded. The Town may authorize, on a case-by-case basis, alternate construction hours. The Owner and/or Applicant shall provide written notice twenty- four (24) hours in advance of modified construction hours. Approval of this request is at discretion of the Town. 32. CONSTRUCTION NOISE: Between the hours of 8:00 a.m. to 8:00 p.m., w eekdays and 9:00 a.m. to 7:00 p.m. weekends and holidays, construction, alteration or repair activities shall be allowed. No individual piece of equipment shall produce a noise level exceeding eighty-five (85) dBA at twenty-five (25) feet from the source. If the device is located within a structure on the property, the measurement shall be made at distances as close to twenty-five (25) feet from the device as possible. The noise level at any point outside of the property plane shall not exceed eighty-five (85) dBA. 33. RELOCATION OF TRASH AND RECYCLING COLLECTION LOCATION: If required with the proposed improvements, prior to the issuance of any permits, an approval letter from West Valley Collection & Recycling accepting the change with the trash and recycling collection location shall be provided to the Town. TO THE SATISFACTION OF THE SANTA CLARA COUNTY FIRE DEPARTMENT: 34. REVIEW: Review of this Developmental proposal is limited to acceptability of site access, water supply and may include specific additional requirements as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work, the applicant shall make application to, and receive from, the Building Department all applicable construction permits. 35. FIRE SPRINKLERS: (As Noted on Sheet A0.0) An automatic sprinkler system shall be provided throughout existing buildings and structures when alterations or additions are made to create conditions described in CFC Sections 903.2.1 through 903.2.18. New S:\PLANNING COMMISSION REPORTS\2022\06-08-2022\Item 2 - 465 N. Santa Cruz Avenue\Exhibit 3 - Recommended Conditions of Approval.docx created R3 unit considered change of occupancy and will therefore require installation of an automatic fire sprinkler system. 36. NOTE: Note that a plan review is required prior to any proposed tenant improvement. 37. GENERAL: This review shall not be construed to be an approval of a violation of the provisions of the California Fire Code or of other laws or regulations of the jurisdiction. A permit presuming to give authority to violate or cancel the provisions of the fire code or other such laws or regulations shall not be valid. Any addition to or alteration of approved construction documents shall be approved in advance. (CFC, Ch.1, 105.3.6) Additional Agency Review 38. ADDITIONAL REQUIREMENTS: Additional agencies may require conformance review or permits for additional requirements, including but not limited to, Santa Clara County Environmental Health Department, West Valley Sanitation, and West Valley Collection and Recycling. This Page Intentionally Left Blank MacDonough Architecture Marcie MacDonough California Architect C33477 160 S. Oak Street 100PMB 192 Sisters, OR 97759 (408) 455-5103 marciemacd@gmail.com Page | 1 of 5 RE: 465 N. Santa Cruz Ave. Conditional Use Permit for Residential Conversion. Written Description The project is at 465 N. Santa Cruz Avenue, Los Gatos. The current site has a 2,430 sf building. It historically has been used for small storefront businesses, such as a vacuum cleaner repair shop and a nail salon. The new owners, Jamie and Dan Pfister are owners of a Real Estate business and plan to move their offices into the front portion of the existing building. They would like to convert the rear 489 sf into a studio apartment. In addition to the residential conversion other work includes improvements of various aspects of the building, such as: Reconfigure interior non-bearing walls Replace all of the existing windows Upgrade HVAC system Upgrade electrical system Add accessible parking Add an accessible bathroom, Demolish the false eave around the back half of the building Remove the clay tile roof on the front portion of the building and replace it with new composition roofing Replace the roofing on the flat portion of the building Remove the carport and shed at the rear of the property Add stucco to the concrete block walls Add a Cornice to the top of the walls Add window flower boxes along the driveway side of the property Add a deep wood header trim above the windows Repaint all exterior finishes Refresh and add more landscape areas as the parking area allows. Add insulation as needed Remove paint from the existing brick EXHIBIT 4 MacDonough Architecture Marcie MacDonough California Architect C33477 160 S. Oak Street 100PMB 192 Sisters, OR 97759 (408) 455-5103 marciemacd@gmail.com Page | 2 of 5 Justification The proposed uses of the property are essential and desirable for the Los Gatos community. The new Real Estate offices and a studio apartment will not impair the integrity and the character of the zone. In fact, the improvements made will only reinforce the character desired in Los Gatos. Nor will the proposed uses be detrimental to public health, safety or general welfare. Maintaining and improving existing commercial spaces are both essential and desirable. The current building is serviceable but does not add to the overall curb appeal that the community desires. The improvements that we will make to the site and building, such as covering existing concrete block with stucco, adding window planter boxes and additional trim work, will create a building that will reinforce the unique scale and character desired in Los Gatos. Please see the Design Justification Section for further visual improvements. Although this portion of the street is primarily commercial, adding more housing to the area will help reduce the pressure on an overtaxed housing market. The idea of mixed-use projects has long been universally championed by urban planners. Mixed-use developments promote improvements in home affordability, walkability to homes, workplaces, and amenities, and strong neighborhoods. It reduces an individual's dependence on expensive and time-consuming transportation modes that syphon resources from better long-term investments. As Los Gatos’s housing shortage deepens, innovative strategies for creating new housing are needed. The owners realize this and have cleverly decided that the extra space in the rear of their building would make an efficient, cost effective, studio residence. By utilizing this existing un-used space for a residence, the owners will be creating a new, desirable and essential housing unit that is within walking distance of downtown Los Gatos. Residents will have walking access to groceries, restaurants, etc. In addition, the VTA 27 route runs along Santa Cruz Avenue, which allows potential tenants easy access to Light Rail, Cal Train and other forms of public transportation. Regardless of the use, the site is currently under parked (see below for calculations). Given the sites limitations, parking has been provided to the maximum extent possible. Even though the zoning parking rules make it appear as if our project is making the parking burden worse, we would argue that we are not increasing the burden. Because it is a mixed-use project there is potential for a Shared Parking Agreement between the residential and office uses on site. We would also argue that, given the neighborhood’s walkability and the access to public transportation, two parking spaces for a 489-square foot studio apartment is likely sufficient without an additional visitor parking space. We formally request the reduction of one guest parking space for the studio apartment. MacDonough Architecture Marcie MacDonough California Architect C33477 160 S. Oak Street 100PMB 192 Sisters, OR 97759 (408) 455-5103 marciemacd@gmail.com Page | 3 of 5 The proposed shared parking agreement hours are: Office: 9am-5pm Monday -Friday Residence: 5pm-9am Monday-Friday, all week-end The various improvements to the property in conjunction with the change in use will only add value and character to the neighborhood and is in harmony with the objectives of the Los Gatos’s General Plan. Parking: Existing Use: Retail Downtown: 1 space per 300 sf 2,430 sf of space = 8.1 (9) spaces needed Existing spaces provided = 6 No ADA space and access aisle provided Deficit = - 3 spaces Proposed Use: Office: 1 space per 250 sf spaces 1941 sf of space: 7.8 Residential: 1.5 Guest Parking: 1 Request for less guest parking: -1 Shared Parking Agreement: -1.5 Total Required: 7.8 Total Provided: 5=6 (ADA Credit) Deficit: -2 spaces We agree to pay the parking in-lieu fee for office use, two deficient parking spaces x $2,000 = $4,000 per town code. MacDonough Architecture Marcie MacDonough California Architect C33477 160 S. Oak Street 100PMB 192 Sisters, OR 97759 (408) 455-5103 marciemacd@gmail.com Page | 4 of 5 Design Guidelines Justification Common Design Guidelines 1.5.1 -1.54 The building is of a size and scale that matches the surrounding buildings. The front and sides of the front portion of the building have a series of large windows that help break up the front to make it a comfortable scale. The front portion of the building is made of natural brick between posts and beams. These post and beams of the structure are and will remain evident and add to the character and the richness of the facade. New fiberglass black windows will be installed to add another layer of depth and interest. On the recessed wall near the entry new stained wood will be added with black business letters, further adding to the layering of the front portion of the building. The rear portion of the building is currently exposed concrete block. The concrete block will be covered over with stucco. This stucco will be tied into the front portion of the building by painting it the same cream color that the post and beams will be painted. A cornice capping the top of the parapet will be added along the side and rear elevations. The side wall along the driveway currently has metal windows. These windows will be replaced with the black fiberglass windows to match the new front windows. The windows will help unify the two portions of the building. Under the windows along the driveway, new window plant boxes will be added to soften and to add interest to this long wall. Additionally, a wide header trim will be added above these windows. 1.5.5 The new trash enclosures will be in the back, well away from public view. However, the enclosure will be made of stucco to match the new stucco on the concrete block walls. 1.5.6 No rooftop equipment will be visible from the public way. Please see A2.1, Roof Plan and Site Line Diagram 1.5.7-1.5.8 The front parking area only has one regular space and one Van Accessible space. As space allows (about 4’), new landscaping will be added to the area between the first spot and sidewalk. There will also continue to be landscaping between the building and the parking area and the side property line and the parking area. 1.5.9 Paint will be removed from the existing brick exposing the rich natural colors of the brick. The heavy timbers and trim will be freshly painted. The exposed concrete block will be covered with stucco. The asphalt at all paved areas in the front portion of the property will be removed and permeable pavers will be used. Please see the color board. MacDonough Architecture Marcie MacDonough California Architect C33477 160 S. Oak Street 100PMB 192 Sisters, OR 97759 (408) 455-5103 marciemacd@gmail.com Page | 5 of 5 1.5.10 Landscaping will be used to surround and soften the front parking area. Pottted plants will be utilized near the front door under the covered entry. 1.5.11 Dark or reflective glazing will not be used 1.5.12 The colors will be muted and will consist of creams, grays and the natural colors of brick and stained wood. Window frames and lighting fixtures will be black. C-1 District 2.2.1 The current entry does not face the street. However, the welcoming front porch, expansive windows on both the front and the sign, the new stained wood wall with black lettering will all serve to make the entrance easily found and to welcome pedestrians into the building. 2.2.2 and 2.2.3, 2.2.5, 2.2.8 Current parking is split between the rear and the front and that will remain the same. We have softened the parking area by adding a landscape buffer and changing the lot surface from asphalt to a permeable herringbone paver. Additional landscaping surrounding the parking area will be maintained and improved upon. 2.2.6 New planted pots will be added surrounding the front entry 2.2.7 No parking area lighting currently exists. If lighting in the parking area is required, the pole will be less than 15’ high and will have luminaires with shielding to direct the light downward This Page Intentionally Left Blank This Page Intentionally Left Blank Pfister Remodel and Change of Use 465 N. Santa Cruz Avenue, Los Gatos, CA Painted Accents BENJIMIN MOORE, 2127-40 Wolf Gray Stucco Cornice Window box Fascia Other wood trim, that is unable to be stained due to condition of existing wood Stucco BENJIMIN MOORE, 2127-40 White Dove Stained Accents – BENJIMIN MOORE, ES-77 Georgetown Gray Window lintels Posts and Beams Pilasters between windows EXHIBIT 6 Pfister Remodel and Change of Use 465 N. Santa Cruz Avenue, Los Gatos, CA Windows – Milgard Trinsic Vinyl Windows, Black Bean Roof– Composition Shingle Dark Gray Exterior Lighting Fixture – The Steel Lighting Company, the Gardena, 16” dome barn light with gooseneck mount Pfister Remodel and Change of Use 465 N. Santa Cruz Avenue, Los Gatos, CA Pavers – CalStone permeable Quarry Stone Sierra Granite 6x9 in Herringbone Pattern This Page Intentionally Left Blank 50'-0"32'-3"32'-0"PROPOSEDSTUDIORESIDENCE,489 SFREMODEL (E)OFFICE, 1,941 SF(E) SIGN TO REMAIN,REPLACE CLAY TILE ROOFUNDER SEPARATE SIGNPERMITREPLACE (E)LANDSCAPING(E)EXISTINGCOVEREDPORCH27'-0"25' MIN. BACK UP(E) SIDEWALK(E) PARK STRIP 4'-3"5'-0"12'-0"(E) DRIVEWAYWM(E) STREET TREE TO REMAIN,PROVIDE PROTECTION PERTOWN CODE18'-0"9'-6"8'-6"21REMOVE (E) STEPS AND GATE(E) CONC. BLOCK WALL ANDWOOD FENCE ABOVE8'-11"SANTA CRUZ AVE.40'-0" TO CENTERLINE OF SANTA CRUZ AVE.18'-0"45(N) ACCESSIBLE VANPARKING8'-0"9'-0"8'-6"(N) LANDSCAPINGPROPERTY LINE38'-6"L=50'L=50'L=130' L=130'(E) ELEC. PANEL TO REMAIN 5'-9"4'-3" 2'-3" NO PARKING4" CONCRETE CURBSURROUNDING ALLLANDSCAPED AREAS(N) WHEEL STOP, TYP.(N) LANDSCAPING(N) TRASH ENCLOSURE,STUCCO WALLS4'-0"8'-4"(N)VAN ACCESSIBLE PARKINGSIGN(E) RETAINING WALL TOREMAINNEW ASPHALT ONDRIVEWAY AND PARKINGSURFACENEW CALSTONE 6X9QUARRY STONEPERMEABLE PAVERSIN HERRINGBONEPATTERN, SIERRAGRANITESEWER GAS WATER POWER (E) SEWER CLEANOUT(E )DRAIN, ADJUST HEIGHTAS NEEDED TO ACCEPT NEWPAVERS(n) 3068 AT GRADE AND LEVELLANDING AT DOOR(E) Residential Site460 Monterey, 410-16-022Edward MarimotoEXISTING BUILDING TOREMAIN, 2430 SF465 N. Santa Cruz Ave.410-16-004Realty World(E) BUILDING467/471 N. Santa Cruz Ave.410-16-003 Doman Watch RepairDesigners Tailoring(E) BUILDING453/455/457/459/461N. Santa Cruz Ave.410-16-005Sweet PeasSign MattersAll Things CleanNEW STRIPING TO FOLLOWTOWN DOUBLE STRIPEGUIDELINES, 4" WIDE WITH18" BETWEEN STRIPES, TYP.(E) GAS METERTO REMAIN,OBSCUREWITH POTTEDPLANTS12'-0"2'-0"(N) DOMELIGHTWITH 11"GOOSENECK,PROTRUDES 20"(24" MAX.), TOMAINTAIN 12'DRIVEWAYCLEARANCE,TYP.Address: 665 N. Santa Cruz Ave.Los Gatos, CA 95030Owners: Dan and Jamie PfisterAPN: 410-16-004Zoning: C-1Type of Construction: V-BNumber of Stories: 1Occupancy Type: B (With R-3 mixed use Proposed)SprinklersYESLot Area:6,500 sfExisting Building Area:2,430 sfParkingExisting Use:Retail Downtown: 1 space per 300 sf2,430 sf of space = 8.1 (9) spaces neededExisting spaces provided = 6No ADA space and access aisle providedProposed Use:Office: 1 space per 250 sf1941 sf of space = 7.7 (8) spacesResidential = 2 spaces + 1 guestTotal: = 11 spaces neededProposed spaces provided: 4ADA and Access aisle provided: 150'-0"32'-3"32'-0"REMOVE (E) PLANTERREMOVE (E)PLANTERREMOVE (E)DISPLAYBOXREPLACE (E)LANDSCAPING(E)EXISTINGCOVEREDPORCH27'-0"25' MIN. BACK UP(E) SIDEWALK(E) PARK STRIP4'-3"5'-0"12'-0"(E) DRIVEWAYWM546(E) STREET TREE TO REMAIN,PROVIDE PROTECTION PERTOWN CODE3REMOVE (E) STEPS AND GATE(E) CONC. BLOCK WALL ANDWOOD FENCE ABOVE8'-11"SANTA CRUZ AVE.40'-0" TO CENTERLINE OF SANTA CRUZ AVE.18'-0"PROPERTY LINEL=50'L=50'L=130'L=130'(E) GAS METERTO REMAIN(E) ELEC. PANEL TO REMAIN(E) RETAINING WALL TOREMAINSEWERGASWATERPOWER(E) SEWER CLEANOUT21EXISTINGPARKINGEXISTINGPARKINGEXISTINGPARKINGREMOVE (E) RAISEDPLANTERS(E) CAPORT AND STORAGEAND TRASH AREA TO BEREMOVED(n) 3068 (E) Residential Site460 Monterey, 410-16-022Edward MarimotoEXISTING BUILDING TOREMAIN, 2430 SF465 N. Santa Cruz Ave.410-16-004Realty World(E) BUILDING467/471 N. Santa Cruz Ave.410-16-003 Doman Watch RepairDesigners Tailoring(E) BUILDING453/455/457/459/461N. Santa Cruz Ave.410-16-005Sweet PeasSign MattersAll Things CleanProposed Site Plan1/8" = 1'-0"1Sheet IndexProject Data Area and Parking DataVicinity MapConditional UsePermit SetResidential Conversion:Dan and Jamie Pfister465 N. Santa Cruz Ave.Los Gatos, CaliforniaSubmittal:SCALE: See DrawingsDATE: May 11, 2022Dan and Jamie Pfister Remodel and Residential Conversion 465 N. Santa Cruz Ave. Los Gatos, CA MacDonough Architecture (408) 455-5103 marciemacd@gmail.comA0.0Cover Sheet/SitePlanCover Sheet, New and Existing Site Plans & Project DataExisting / Demo Floor Plan & ElevationsProposed Floor/Roof PlansRoof Plan and Site line Schematic SectionsProposed ElevationsAo.oA1.0A2.0A2.1A3.0NProject LocationNExisting/Demo Site Plan1/8" = 1'-0"2NScope of Work·Convert the existing rear 489 sf of office space into a studioapartment.·Reconfigure interior non-bearing walls·Replace all of the existing windows·Upgrade HVAC system·Upgrade electrical system·Add accessible parking·Add an accessible bathroom·Demolish the false eave around the back half of the building·Remove the clay tile roof on the front portion of the buildingand replace it with new composition roofing·Replace the roofing on the flat portion of the building·Remove the carport and shed at the rear of the property·Add stucco to the concrete block walls·Add a Cornice to the top of the walls·Add window flower boxes along the driveway·Add a wide wood header trim above the windows·Repaint all exterior finishes·Refresh and add more landscape areas as the parking areaallows.·Add insulation as needed·Remove paint from the existing brickEXHIBIT 7 9'-9"26'-3"24'-0" 13'-2"4'-8"(E)COVEREDENTRY(e) 366836'-0"36'-2"24'-8" 50'-0" 74'-0"(E) OFFICESPACE(E) OFFICESPACE(E) OFFICESPACE(E) BATH(E) BATH(E) OFFICESPACE-2-4-3-5(E) CARPORT (E) STORAGE (E) BUILDING ON ADJACENT LOT, NO WORK (e) 3668(E) CLAY TILE ROOFINGTO BE REMOVED(E) PAINTED BRICK TOREMAIN, TYP.REMOVE (E) PLANTERREPLACE (E) WINDOWS,TYP.REMOVE (E) PLANTERREMOVE (E) FALSE EAVEREMOVE (E) DISPLAYCABINET(E) PAINTEDCONCRETE BLOCKTO REMAIN, TYP.16'-10"Indicates Construction to be RemovedIndicates Existing Construction toRemain14'-01 8"REMOVE (E) FALSE EAVE(E) CREAM PAINTED CONCRETEBLOCK TO REMAIN, TYP.REMOVE (E) MUSTARDCOLORED METALWINDOWS, TYP.REMOVE PLANTERREMOVE PLANTERREMOVE PLANTER(E) CARPORT AND STORAGEAREA TO BE REMOVED(E) WALL OF NEIGHBORBUILDING BEYOND TO REMAINREMOVE(E) MUSTARDPAINTED DOORREMOVE SPANISH CLAYTILECONCRETE BLOCK WALL ALONG PROPERTY LINE ANDADJACENT TO NEIGHBORING BUILDING - NO WORKREMOVE (E) WINDOWSREMOVE (E) DOORREMOVE (E) WINDOWREMOVE (E) FALSE EAVESubmittal:SCALE: See DrawingsDATE: May 11, 2022Dan and Jamie Pfister Remodel and Residential Conversion 465 N. Santa Cruz Ave. Los Gatos, CA MacDonough Architecture (408) 455-5103 marciemacd@gmail.comA1.0Existing / DemoPlansDemolition Plan Legend:1/4" = 1'-0"1Existing / Demolition 1st Floor Plan·Contractor shall perform demolition as required toachieve new floor plan·Contractor shall consult with owner regarding allmaterials scheduled for removal to determine whatwill be re-used, stored or discarded·Contractor shall patch and repair all constructionscheduled to remain which is affected duringdemolition.·Cap off or relocated all plumbing as required per newplan layout.·Recycle and/or salvage for re-use a minimum of 50%of the nonhazardous construction and demolitionwaste in accordance with either Section 4.408.2.,4.408.3, or 4.408.4.Demolition General Notes:1. Remove windows, dispose of as directed by the owner,typical where shown2. Remove (e) ramp3. Remove doors and save as directed by the owner,typical where shown4. Demolish existing walls as indicated by legend. Prior toremoval ensure structural stability. Contractor shall beresponsible for all temporary shoring of the structureduring construction.5. Remove plumbing fixtures and cap. Save or dispose ofper owners' instructions.6. Remove (E) false eave7. Remove and replace (e) HVAC and Hot Water heater8. Remove (e) carport and storage, see site plan, roofplan, and elevation for extent of carportDemo Keynotes:1Typ.1/8" = 1'-0"2Existing Front Elevation1/8" = 1'-0"3Existing Side Elevation1/8" = 1'-0"5Existing Rear Elevation1/8" = 1'-0"4Existing Side Elevation243Typ.Typ.75Typ.6Typ.78NPhoto of Front of ExistingBuildingPhoto of Side of ExistingBuildingPhoto of Corner of ExistingBuildingPhoto of Side of ExistingBuildingPhoto of Rear of ExistingBuilding88NO EXTERIOR WALLSTO BE REMOVED. NEWWINDOWS TO FIT INEXISTING OPENINGS 9'-9"26'-3"24'-0" 13'-2" 11'-2"4'-8"11'-3"11'-9"4'-8"4'-1"6'-9" RAMP DN 1:1212'-2"11'-0" (n) 3068 11'-0"11'-9"12'-1"6'-6" MODELNUMBERu.c.refMODELNUMBER 3'-2 12"(n) 30684'-1" 11'-3"11'-0"5'-1112"3'-0"2668 MODELNUMBER D.W.24"aptref.2668W/DWICBATHSTUDIOAPARTMENTCONFERENCEROOMCOFFEEAREAPOWDERTANKLESSH.W.ADABATHROOM7'-6"(n) 3068(n) 3068(n) 3068(n) 3068(n) 3068(n) 3068(n) barn doorsCOPY ROOMAND STORAGEOFFICE #2OFFICE #1OFFICE #4OFFICE #3KITCHEN(E)COVEREDENTRY(n) 3068 (n) 3668 (t)STEP DN (n) 3668 (t)36'-0"36'-2"24'-8" 50'-0" 74'-0"(E) BATH11'-11"11'-11" 7'-9"A3.03A3.04A3.02A3.01(E) BUILDING ON ADJACENT LOT, NO WORK Indicates Existing Construction toRemainIndicates New ConstructionSubmittal:SCALE: See DrawingsDATE: May 11, 2022Dan and Jamie Pfister Remodel and Residential Conversion 465 N. Santa Cruz Ave. Los Gatos, CA MacDonough Architecture (408) 455-5103 marciemacd@gmail.comA2.0Proposed FloorPlanProposed Floor Plan1/4" = 1'-0"1Floor Plan Legend:N (N) AND (E) ROOFTOP EQUIPMENT+/- 2:12, V.I.F.REPLACE (E) CLAYTILE WITH (N) DARKGRAY COMPOSITIONSHINGLE ROOFREMOVE DECORATIVEROOF FRONT(E) PARAPET WALLTO REMAIN3-3-CURVED TOP OF (E) TRUSS TOREMAIN, REROOFREMOVE OLD HVACEQUIPMENT2-REMOVE CARPORT2-(E) AND (N) ROOF TOPEQUIPMENT BELOW SITE LINESFROM THE PUBLIC RIGHT OF WAYPEDESTRIAN STANDING ONTHE OPPOSITE SIDEWALKPEDESTRIAN STANDING INTHE CENTER OF THE STREETPEDESTRIAN STANDING ON SIDEWALKIN FRONT OF PROPERTYSTUDIOAPT.RECEPTION AREAOFFICE AREA16'-11" 16'-6"(E) AND (N) ROOF TOP EQUIPMENT(E) TRUSS TO REMAIN(E) NEIGHBOR WALL12'-0"(E) DRIVEWAY(E) BUILDING WALL,NEIGHBORING PROPERTY(E) FRONT PARAPETOFFICE AREASubmittal:SCALE: See DrawingsDATE: May 11, 2022Dan and Jamie Pfister Remodel and Residential Conversion 465 N. Santa Cruz Ave. Los Gatos, CA MacDonough Architecture (408) 455-5103 marciemacd@gmail.comA2.1Proposed RoofPlanExisting / Proposed Roof Plan1/8" = 1'-0"1NSite Line Diagram for Rooftop Equipment1/8" = 1'-0"3Schematic Section for Rooftop Equipment1/8" = 1'-0"2 Submittal:SCALE: See DrawingsDATE: May 11, 2022Dan and Jamie Pfister Remodel and Residential Conversion 465 N. Santa Cruz Ave. Los Gatos, CA MacDonough Architecture (408) 455-5103 marciemacd@gmail.comA3.0Elevations1/4" = 1'-0"1Proposed Front Elevation 1/4" = 1'-0"2Proposed Rear Elevation 1/4" = 1'-0"3Proposed Side (Driveway) Elevation 1/4" = 1'-0"4Proposed Side Elevation (N) DARK GRAYCOMPOSITIONSHINGLE ROOFPAINT (E) POST, BENJAMINMOORE, WHITE DOVE, OC-171" X 8" DEEP STUCCO CORNICE,PAINT BENJAMIN MOORE, WOLFGRAY 2127-40(N) STAINED HORIZONTAL T&G WOODPLANK SIDING, SEMI-SOLID BENJIMINMOORE GEORGETOWN GRAY, TYP.PAINT TRIM BENJAMIN MOORE,WHITE DOVE, OC-17REMOVE (E) PAINT FROMBRICK TO EXPOSENATURAL COLORS(N) BLACK LETTERING ON STAINED WOODSIDING, EXACT SIZE AND STYLE TBD, APPLYFOR SIGN PERMITPAINT RAFTERS AND FASCIA BENJAMINMOORE, WHITE DOVE, OC-17Realty WorldMilestone16'-10"POTTED PLANTS TO OBSCURE (E)GAS METER FROM PUBLIC WAY5/4" X 8" CORNER TRIM, PAINTBENJAMIN MOORE, WHITE DOVE,OC-17NEW SMALLER WINDOW(N) RESIDENCE ENTRY DOORPAINTREPLACEMENT WINDOWFILL IN AND PATCH WALL(N) STUCCO OVER (E) CONCRETE BLOCKWALL, TYP. PAINT BENJIMIN MOORE, WHITEDOVE, OC-171"X 8" DEEP STUCCO CORNICE,PAINT BENJAMIN MOORE, WOLFGRAY 2127-4014'-0 1 8"NEW MILGARD INTRINSIC, VINYLWINDOWS, BLACK BEAN TYP.(N) STUCCO OVER (E) CONCRETE BLOCKWALL, TYP. PAINT BENJIMIN MOORE, WHITEDOVE, OC-171"X 8" DEEP STUCCO CORNICE,PAINT BENJAMIN MOORE, WOLFGRAY 2127-40NEW WINDOW PLANT BOX, 12"WIDE AND 8" DEEP, PAINTBENJAMIN MOORE, WOLF GRAY2127-40WOOD 2X8 LINTEL WINDOWTRIM, STAIN, SEMI-SOLIDBENJIMIN MOORE GEORGETOWNGRAY, TYP.GARDENA 16" DOME BARN LIGHT,BY STEEL LIGHTING, CO., TYP.REMOVE (E) PAINT FROMBRICK TO EXPOSENATURAL COLORSPAINT BARGE BOARD AND TRIMBENJAMIN MOORE, WHITE DOVE, OC-17NEW WOOD DOOR WITH WINDOW GLAZING,PAINT BENJAMIN MOORE, WOLF GRAY2127-40, TYP.CONCRETE BLOCK WALLALONG PROPERTY LINEAND ADJACENT TONEIGHBORING BUILDING- NO WORKWOOD TRIM, PAINT,BENJAMIN MOORE, WOLFGRAY 2127-40 , TYP.(N) STUCCO OVER (E) CONCRETE BLOCKWALL, TYP. PAINT BENJIMIN MOORE, WHITEDOVE, OC-17WOOD TRIM, PAINT,BENJAMIN MOORE, WOLFGRAY 2127-40 , TYP.WOOD TRIM, PAINT,BENJAMIN MOORE, WOLFGRAY 2127-40 , TYP. This Page Intentionally Left Blank