Loading...
Item 04 - 52 Oak Grove Ave - Staff Report & Exhibits 1-8TOWN OF LOS GATOS ITEM NO: 4 PLANNING COMMI SSION STAFF REPORT Meeting Date : June 22, 2016 PREPARED BY: APPLICATION NO: LOCATION : APPLICANT/ CONTACT PERSON: PROPERTY OWNER: Jennifer Armer, Associate Planner jarmer@losgatosca.gov Architecture and Site Application S-16-041 52 Oak Grove A venue (located at the southern terminus of Oak Grove A venue) Jennifer Kretschmer, AlA Bob & Eleanor Tullis APPLICATION SUMMARY: Requesting approval to construct a new second story addition to an existing single-family residence on property zoned R-1 :8. APN 529-30-025 . RECOMMENDATION : PROJECT DATA: DEEMED COMPLETE: May 19,2016 FINAL DATE TO TAKE ACTION: November 19 ,2016 Denial General Plan Designation: Zoning Designation: Low Density Residential R-1 :8 -Single-Family Residential , 8,000-square foot lot m1mmum Applicable Plans & Standards: General Plan; Residential Design Guidelines; Parcel Size: 11 ,426 gross square feet Surrounding Area: Existing Land Use General Plan Zoning North Residential Low Density Residential R-1 :8 East Residential Low Density Residential R-1 :8 South Open Space Open Space RC West Open Space Open Space RC Planning Commission Staff Report -Page 2 52 Oak Grove A venue/S-16-041 June 22, 2016 CEQA: FINDINGS: CONSIDERATIONS : ACTION : EXHIBITS : BACKGROUND : The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. • As required , pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, this project is Categorically Exempt, Section 15303: New Construction or Conversion of Small Structures . • As required by the Residential Design Guidelines that the project complies with the Residential Design Guidelines. • As required by Section 29.20.150 of the Town Code for granting approval of an Architecture and Site application. The decision of the Planning Commission is final unless appealed within ten days . 1. Location Map 2. Findings 3 . Recommended Conditions of Approval 4 . Project Data Sheet (one page) 5. Applicant's letter ofJustification, received March 14, 2016 (one page) 6. Town's Consulting Arborist report dated May 18 , 2016 (eight pages) 7 . Town's Consulting Architect report , dated May 5, 2016 (four pages) 8 . Currently proposed Development Plans, received June 3, 2016 (14 pages) The subject site is a conforming lot located adjacent to Novitiate Park at the southern terminus of Oak Grove Avenue (see Exhibit 1). The flat but irregularly-shaped lot is 11 ,426 square feet with a 1 ,915-square-foot single-story residence and a 368-square-foot detached garage. The project is being forwarded to the Planning Commission because the project would result in the largest house in terms of square feet and the second largest in terms ofF AR in the immediate area and proposes a two-story fa<;ade in a primarily single-story immediate neighborhood. Planning Commission Staff Report -Page 3 52 Oak Grove A venue/S-16-041 June 22 , 2016 PROJECT DESCRIPTION: A. Architecture and Site Application The applicant is proposing a 1,216-square-foot addition to the existing residence. The proposed addition includes 68 square feet on the ground floor and a new1,148-square foot second story. No new floor area is proposed for the detached garage. The project would have a maximum height of 25 feet , six inches. The proposed materials include: hardie siding, fiber cement board shingle, hardie plank fiber cement board painted trim, milgard ultra fiberglass windows, and a composition roof. A color and material board will be available at the Planning Commission meeting, and Exhibit 4 includes general project data. B. Location and Surrounding Neighborhood The project site is located at the southern terminus of Oak Grove Avenue. Novitiate Park is on both the southern and western borders of the property and single-family homes are located to the north and east (Exhibit 1). Surrounding properties contain single-family residences. C . Zoning Compliance The proposed project complies with the height and structure coverage limitations. The proposed project complies with setback requirements and all required parking is being provided on-site. The zoning permits a single-family residence. ANALYSIS : A. Floor Area Based on Town and County records, the residences in the immediate area range in size from 1,066 square feet to 2,920 square feet. The floor area ratios (FAR) range from 0.11 FAR to 0.31 FAR. The proposed residence would be 3,131 square feet with a 0.27 FAR . Pursuant to Town Code, the maximum square footage for the lot size is 3,416 square feet with a 0.29 FAR. The following Neighborhood Analysis table (next page) reflects current conditions of the immediate area. Planning Commission StaffReport-Page 4 52 Oak Grove A venue/S-16-041 June 22, 2016 ADDRESS House 40 Oak Grove A venue 2 ,178 42 Oak Grove A venue 1,955 46 Oak Grove Ave 2 ,550 52 Oak Grove Ave (E) 1,915 52 Oak Grove Ave (P) First Floor 1,983 52 Oak Grove Ave (P) Second Floor 1,148 52 Oak Grove Ave (P) Total 3,131 56 Oak Grove A venue 2,002 62 Oak Grove A venue 1,461 66 Oak G rove A venue 1,066 70 Oak Grove A venue 2 ,92 0 76 Oak Grove A venue 1,63 1 Garage 0 386 803 368 368 368 493 294 380 377 360 House House and garage Lot size FAR Stories 2,178 9,983 0 .22 1 2 ,341 8,170 0.24 1 3,353 9,392 0.27 2 2,283 11,426 0 .17 1 2,351 1,148 2 3 ,499 11,426 0.27 2 ,495 14 ,450 0 .14 1 1,7 55 9,100 0.16 1 1,446 8,666 0.12 1 3,297 9,468 0.31 2 1,99 1 14,978 0.11 1 At 3,131 square feet , the proposed residence would be the largest home in the immediate area and due to the lot area, its FAR would be the second largest. The project was referred to the Planning Commission because it would result in the largest residence in the immediate area. The proposed residence would be 211 square feet larger than the largest in the immediate area. The Residential Design Guidelines specify that residential development shall be similar in mass, bulk, and scale to the immediate neighborhood. The Guidelines also specify that consideration will be given to the existing F ARs, residential square footages , and lot sizes in the neighborhood. The applicant provides justification for the proposed residence in Exhibit 5. While the second story addition is set well back from the neighbors, and the Town 's Consulting Architect has found that the proposed renovation with its "strong, traditional architectural style and rel atively small scale would make this a positive addition to the neighborhood with a few modifications," staff recommends denial because the proposed home would be approximately 2 11 square feet larger than the largest home in the immediate area and is surrounded by single story facades along both sides of the street. B. Tree Impacts The project site contains four trees ( onsite and adjacent) that may be impacted by this project. Staff requested that the Town 's Consulting Arborist r eview the project (Exhibit 6) and provide recommenda tions for protecting these trees. One tree on-site (38-inch trunk Planning Commission Staff Report -Page 5 52 Oak Grove A venue/S-16-041 June 22 , 2016 diameter valley oak) is immediately adjacent to the existing building. The proposed second story has been designed to be outside of the tree's canopy. The other three trees are not immediately adjacent but could potentially be impacted by materials, equipment and miscellaneous work during construction. The Town's Consulting Arborist recommends tree protection fencing for all four trees, and provides specific additional direction for protection and trimming of the valley oak on-site. If the project is approved, tree protection measures would be implemented prior to and during construction. Tree protection measures are incorporated as conditions of approval (Exhibit 3) to protect the trees. C. Architectural Considerations Staff requested that the Town's Architectural Consultant review the project (Exhibit 7) to provide recommendations regarding architecture and neighborhood compatibility. Staffs initial concerns were that the large square footage and uninterrupted two-story front favade would not be compatible with the surrounding single-story homes, even with the proposed side setbacks (significantly greater than required) and single-story element on the right side of the favade. The consultant identified several recommended changes in order to bring the project into compliance with the Town 's Residential Design Guidelines. The applicant made all changes recommended by the Consultant, which resulted in a house that was more compatible with the scale of the surrounding neighborhood, and approximately 200 square feet less than originally proposed. The revisions are incorporated into the final development plans included in Exhibit 8. D. Environmental Review The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. PUBLIC COMMENTS: At this time, the Town has not received any public comment. The applicant has informed staff that they have met with the majority of the adjacent neighbors. SUMMARY AND RECOMMENDATION: A. Summary As currently proposed, the project would create a residence that is approximately 211 square feet larger than the largest home in the immediate area with a two-story front favade Planning Commission Staff Report-Page 6 52 Oak Grove Avenue/S-16-041 June 22, 2016 surrounded by single-story fa9ades. The applicant has worked with staff to address architectural concerns and to ensure protection of the protected trees on and off site. B. Recommendation Staff recommends denial ofthe Architecture and Site application based on the size ofthe residence in comparison to those in the immediate area and the proposal for a two-story front fa9ade on a street that is primarily single-story residences. ALTERNATIVES: Alternatively, the Commission could: 1. Approve the application by taking the following actions: a. Find that the proposed project is categorically exempt, pursuant to Section 15303 of the California Environmental Quality Act as adopted by the Town (Exhibit 2); and b. Make the finding that the project complies with the Residential Design Guidelines (Exhibit 2); and c. Make the required considerations as required by Section 29.20.150 of the Town Code for granting approval of an Architecture & Site application (Exhibit 2); and d. Approve Architecture and Site Application S-16-041 with the conditions contained in Exhibit 3 and development plans attached as Exhibit 8; or 2. Approve the application with additional and/or modified conditions ; or 3. Continue the matter to a date certain with specific direction. P..J'eParetl by: ~~iler Armer, AICP Associate Planner JP:JA:cg --:z:v~(?Kc=t? /Joel Paulson, AICP Community Development Director cc: Jennifer Kretschmer, AlA, 101 Old Blossom Hill Rd, Los Gatos , CA 95031 N :\DEV\PC REPORTS\2 016\0ak Grove 52.docx 52 Oak Grove Avenue N + EXHIBIT 1 This Page Intentionally Left Blank PLANNING COMMISSION-June 22, 2016 REQUIRED FINDINGS & CONSIDERATIONS FOR: 52 Oak Grove A venue Architecture and Site Application S-16-041 Requesting approval to construct a new second story addition to an existing single-family residence on property zoned R-1:8. APN 529-30-025 . PROPERTY OWNER: Bob & Eleanor Tullis APPLICANT: Jennifer Kretschmer, AlA FINDINGS Required finding for CEQA: • The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act , Section 15303: New Construction or Conversion of Small Structures. Required Compliance with the Residential Design Guidelines: • The project is in compliance with the Residenti al Design Guidelines for single-family homes not in hill s ide residential areas. CONSIDERATIONS Required considerations in review of Architecture & Site applications: • As required by Section 29.20.150 of the Town Code, the considerations in review of an Architecture and Site application were all made in reviewing thi s project. N:\DEV\FI DINGS\2 0 16\0AK GROVE 52.DO CX EXHIBIT 2 This Page Intentionally Left Blank PLANNING COMMISSION -June 22,2016 CONDITIONS OF APPROVAL 52 Oak Grove A venue Architecture and Site Application S-16-041 Requesting approval to construct a new second story addition to an existing single-family residence on property zoned R-1:8. APN 529-30-025. PROPERTY OWNER: Bob & Eleanor Tullis APPLICANT: Jennifer Kretschmer, AlA TO THE SATISFACTION OF THE DIRECTOR OF COMMUNITY DEVELOPMENT: Planning Division I. APPROVAL: This application shall be completed in accordance with all of the conditions of approval and in substantial compliance with the approved plans. Any changes or modifications to the approved plans and /or business operation shall be approved by the Community Development Director, DRC or the Planning Commission depending on the scope of the changes. 2. EXPIRATION: The approval will expire two years from the approval date pursuant to Section 29.20.320 of the Town Code, unless the approval has been vested. 3. OUTDOOR LIGHTING : Exterior lighting shall be kept to a minimum, and shall be down directed fixtures that will not reflect or encroach onto adjacent properties. No flood lights shall be used unless it can be demonstrated that they are needed for safety or security. The lighting plan shall be reviewed during building plan check. 4. GENERAL: All existing trees shown on the plan and trees required to remain or to be planted are specific subjects of approval of this plan, and must remain on the site. 5. TREE REMOVAL PERMIT: A Tree Removal Permit shall be obtained for any trees to be removed, prior to the issuance of a building or grading permit. 6 . ARBORIST REQUIREMENTS: The developer shall implement, at their cost, all recommendations made by Deborah Ellis, identified in the Arborist' s report dated May 18, 2016, on file in the Community Development Department. A Compliance Memorandum shall be prepared by the applicant and submitted with the building permit application detailing how the recommendations have or will be addressed. These recommendations must be incorporated in the building permit plans, and completed prior to issuance of a building permit where applicable. 7. TREE FENCING: Protective tree fencing and other protection measures shall be placed at the drip line of existing trees prior to issuance of demolition and building permits and shall remain through all phases of construction. Refer to tree fencing requirements and other protection measures identified in the Arborist Report prepared by Deborah Ellis dated May 18 , 2016, on file in the Community Development Department. Include a tree protection plan with the construction plans. 8. SALVAGE OF BUILDING MATERIALS: Prior to the issuance of a d emolition permit, the deve loper shall provide the Community Development Director with written notice of the company that will be recycling the building materials. All wood, metal , glass, and aluminum materials generated from the demolished structure shall be deposited to a co mpany which will recycle the materials. Receipts from the company(s) accepting these EXHIBIT 3 materials, noting the type and weight of materials, shall be submitted to the Town prior to the Town's demolition inspection. 9. DEMOLITION AFFIDAVIT: Applicant shall complete and submit the Town's Demolition Affidavit with all demolition and/or building permit application(s). 10. STORY POLES: The story poles on the project site shall be removed within 30 days of approval of the Architecture & Site application. 11. TOWN INDEMNITY : Applicants are notified that Town Code Section 1.10.115 requires that any applicant who receives a permit or entitlement from the Town shall defend, indemnify, and hold harmless the Town and its officials in any action brought by a third party to overturn, set aside, or void the permit or entitlement. This requirement is a condition of approval of all such permits and entitlements whether or not expressly set forth in the approval , and may be secured to the satisfaction of the Town Attorney. 12 . COMPLIANCE MEMORANDUM: A memorandum shall be prepared and submitted with the building plans detailing how the Conditions of Approval will be addressed. TO THE SATISFACTION OF THE DIRECTOR OF PARKS AND PUBLIC WORKS: Engineering Division 13 . GENERAL: All public improvements shall be made according to the latest adopted Town Standard Plans, Standard Specifications and Engineering Design Standards. All work shall conform to the applicable Town ordinances. The adjacent public right-of-way shall be kept clear of all job-related dirt and debris at the end of the day. Dirt and debris shall not be washed into storm drainage facilities. The storing of goods and materials on the sidewalk and/or the street will not be allowed unless an encroachment permit is issued. The Applicant's representative in charge shall be at the job site during all working hours. Failure to maintain the public right-of-way according to this condition may result in the Town performing the required maintenance at the Applicant's expense. 14. APPROVAL: This application shall be completed in accordance with all of the conditions of approval listed below and in substantial compliance with the latest reviewed and approved development plans. Any changes or modifications to the approved plans or conditions of approvals shall be approved by the Town Engineer. 15. ENCROACHMENT PERMIT: All work in the public right-of-way will require a Construction Encroachment Permit. All work over $5 ,000 will require construction security. It is the responsibility of the Applicant to obtain any necessary encroachment permits from affected agencies and private parties, including but not limited to, Pacific Gas and Electric (PG&E), AT&T, Comcast, Santa Clara Valley Water District, California Department of Transportation (Caltrans). Copies of any approvals or permits must be submitted to the Town Engineering Division of the Parks and Public Works Department prior to releasing any permit. 16. RESTORATION OF PUBLIC IMPROVEMENTS: The Applicant shall repair or replace all existing improvements not designated for removal that are damaged or removed because of the Applicant's operations. Improvements such as, but not limited to: curbs, gutters, sidewalks, driveways, signs, pavements, raised pavement markers, thermoplastic pavement markings , etc., shall be repaired and replaced to a condition equal to or better than the original condition. Any new concrete shall be free of stamps , logos , names, graffiti, etc. Any concrete identified that is displaying a stamp or equal shall be removed and replaced at the Contractor's sole expense and no additional compensation shall be allowed therefore. Existing improvement to be repaired or replaced shall be at the direction of the Engineering Construction Inspector, and shall comply with all Title 24 Disabled Access provisions. The Applicant shall request a walk-through with the Engineering Construction Inspector before the start of construction to verify existing conditions . 17. SITE SUPERVISION: The General Contractor shall provide qualified supervision on the job site at all times during construction. 18. STREET CLOSURE: Any proposed blockage or partial closure of the street requires an encroachment permit. Special provisions such as limitations on works hours, protective enclosures, or other means to facilitate public access in a safe manner may be required. 19 . SOILS REPORT: One copy of the soils and geologic report shall be submitted with the application . The soils report shall look at the potential liquefaction with respect to the existing foundations and the proposed new construction; examine the existing foundations to confirm satisfactory performance to date; provide recommendations on whether the existing foundations can support the loads from the weight of the new story (and corresponding settlement); and/or provide geotechnical design recommendations for new foundation elements (and corresponding settlement). The report shall be signed and "wet stamped" by the engineer or geologist, in conformance with Section 6735 of the California Business and Professions Code. 20. GEOLOGY AND SOILS MITIGATION MEASURE : A geotechnical investigation shall be conducted for the project to determine the surface and sub-surface conditions at the site and to determine the potential for surface fault rupture and liquefaction on the site. The geotechnical study shall provide recommendations on whether the existing foundations can support the loads from the weight of the new story (and corresponding settlement); and/or provide geotechnical design recommendations for new foundation elements (and corresponding settlement). All recommendations of the investigation shall be incorporated into project plans prior to the issuance of any permits . 21. SOILS REVIEW: Prior to issuance of any permits, the Applicant's engineers shall prepare and submit a design-level geotechnical/geological investigation for review and approval by the Town. The Applicant's soils engineer shall review the final grading and drainage plans to ensure that designs for foundations , retaining walls, site grading, and site drainage are in accordance with their recommendations and the peer review comments. Approval of the Applicant's soils engineer shall then be conveyed to the Town either by letter or by signing the plans. 22. SOIL RECOMMENDATIONS: The project shall incorporate the geotechnical/geological recommendations contained in the project's design-level geotechnical/geological investigation as prepared by the Applicant's engineers, and any subsequently required report or addendum. Subsequent reports or addendum are subject to peer review by the Town's consultant and costs shall be borne by the Applicant. 23 . TRENCHING MORATORIUM: Trenching within a newly paved street will be allowed subject to the following requirements: a. The Town standard "T" trench detail shall be used. b . A Town-approved colored controlled density backfill shall be used. c. All necessary utility trenches and related pavement cuts shall be consolidated to minimize the impacted area of the roadway. d. The total asphalt thickness shall be a minimum of three (3) inches, meet Town standards, or shall match the existing thickness, whichever is greater. The final lift shall be 1.5-inches of one-half(~) inch medium asphalt. The initiallift(s) shall be of three-quarter(~) inch medium asphalt. e. The Contractor shall schedule a pre-paving meeting with the Town Engineering Construction Inspector the day the paving is to take place. f. A slurry seal topping may be required by the construction inspector depending their assessment of the quality of the trench paving. If required, the slurry seal shall extend the full width of the street and shall extend five (5) feet beyond the longitudinal limits of trenching. Slurry seal materials shall be approved by the Town Engineering Construction Inspector prior to placement. Black sand may be required in the slurry mix . All existing striping and pavement markings shall be replaced upon completion of slurry seal operations. All pavement restorations shall be completed and approv ed by the Inspector before occupancy. 24. GUTTER REP AIR: The Applicant shall repair and replace to existing Town standards any gutter damaged now or during construction of this project. All new and existing adjacent infrastructure must meet Town standards. New gutter shall be constructed per Town Standard Details. New concrete shall be free of stamps, logos, names, graffiti , etc. Any concrete identified that is displaying a stamp or equal shall be removed and replaced at the Contractor's sole expense and no additional compensation shall be allowed therefore. The limits of gutter repair will be determined by the Engineering Construction Inspector during the construction phase of the project. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. 25 . CONSTRUCTION STREET PARKING: No vehicle having a manufacture 's rated gross vehicle weight exceeding ten thousand (10 ,000) pounds shall be allowed to park on the portion of a street which abuts property in a re sidential zone without prior to approval from the Town Engineer. 26. HAU LING OF SOIL: Hauling of soil on-or off-site shall not occur during the morning or evening peak periods (between 7 :00a.m. and 9 :00a.m. and between 4:00p.m. and 6:00 p.m.). Prior to the issuance of a building permit, the Applicant shall work with th e Town Building Department and Engineering Division Inspectors to devise a traffic control plan to ensure safe and efficient traffic flow under periods when soil is hauled on or off of the project site. This may include, but is not limited to provisions for the Applicant/Owner to place construction notification signs noting the dates and time of construction and hauling activities , or providing additional traffic control. Coordination with other significant projects in the area may also be required. Cover all trucks hauling soil , sand and other loose debris. 27. CONSTRUCTION HOURS: All subdiv ision improvements and site improvements construction activities, including the delivery of construction materials , labors, heavy equipment, supplies, etc., shall be limited to the hours of 8:00 a.m. to 8 :00 p .m., weekdays and 9 :00a.m. to 7:00p.m. weekends and holidays. The Town may authori ze, on a case-by- case basis, alternate construction hours. The Applicant shall provide written notice twenty- four (24) hours in advance of modified construction hours. Approval of thi s request is at di scretion of the Town. 28. CONSTRUCTION NOISE: Between the hours of 8:00 a.m. to 8:00 p.m., weekdays and 9:00 a.m. to 7:00 p.m . we ekends and holidays, construction, alterati on or repair activities shall be allowed. No individual piece of equipment shall produce a noise level exceeding eighty-five (85) dBA at twenty-five (25) feet from the source. If the device is located within a structure on the property, the measurement shall be made at distances as close to twenty-five (25) feet from the device as possible. The noise level at any point outside of the property plane shall not exceed eighty-five (85) dBA. 29. CONSTRUCTION MANAGEMENT PLAN: Prior to the issuance of any permits, the Applicant shall submit a construction management plan that shall incorporate at a minimum the Project Schedule, site security fencing, employee parking, construction staging area, materials storage area(s), concrete washout(s) and proposed outhouse location( s ). 30. WVSD (West Valley Sanitation District): Sanitary sewer laterals are televised by West Valley Sanitation District and approved by the Town of Los Gatos before they are used or reused. A Sanitary Sewer Clean-out is required for each property at the property line, or at a location specified by the Town. 31. SANITARY SEWER BACKWATER VALVE : Drainage piping serving fixtures which have flood level rims less than twelve (12) inches (304.8 mm) above the elevation of the next upstream manhole and/or flushing inlet cover at the public or private sewer system serving such drainage piping shall be protected from backflow of sewage by installing an approved type backwater valve . Fixtures above such elevation shall not discharge through the backwater valve, unless first approved by the Building Official. The Town shall not incur any liability or responsibility for damage resulting from a sewer overflow where the property owner or other person has failed to install a backwater valve as defined in the Uniform Plumbing Code adopted by the Town and maintain such device in a functional operation condition. Evidence of West Sanitation District's decision on whether a backwater device is needed shall be provided prior to the issuance of a building permit. 32. BEST MANAGEMENT PRACTICES (BMPs): The Applicant is responsible for ensuring that all contractors are aware of all storm water quality measures and that such measures are implemented. Best Management Practices (BMPs) shall be maintained and be placed for all areas that have been graded or disturbed and for all material, equipment and/or operations that need protection. Removal of BMPs (temporary removal during construction activities) shall be replaced at the end of each working day. Failure to comply with the construction BMP will result in the issuance of correction notices, citations, or stop work orders. 33 . SITE DESIGN MEASURES: All projects shall incorporate the following measures: a. Protect sensitive areas and minimize changes to the natural topography. b. Minimize impervious surface areas. c. Direct roof downspouts to vegetated areas . d. Use permeable pavement surfaces on the driveway, at a minimum. e. Use landscaping to treat stormwater. 34. EROSION CONTROL: Interim and final erosion control plans shall be prepared and submitted to the Engineering Division of the Parks and Public Works Department. A maximum of two (2) weeks is allowed between clearing of an area and stabilizing/building on an area if grading is allowed during the rainy ·season. Interim erosion control measures, to be carried out during construction and before installation of the final landscaping, shall be included . Interim erosion control method shall include, but are not limited to : silt fences, fiber rolls (with locations and details), erosion control blankets, Town standard seeding specification, filter berms, check dams, retention basins, etc. Provide erosion control measures as needed to protect downstream water quality during winter months . The Town of Los Gatos Engineering Division of the Parks and Public Works Department and the Building Department will conduct periodic NPDES inspections of the site throughout the recognized storm season to verify compliance with the Construction General Permit and Stormwater ordinances and regulations. 35 . DUST CONTROL: Blowing dust shall be reduced by timing construction activities so that paving and building construction begin as soon as possible after completion of grading, and by landscaping disturbed soils as soon as possible. Further, water trucks shall be present and in use at the construction site. All portions of the site subject to blowing dust shall be watered as often as deemed necessary by the Town, or a minimum of three (3) times daily, or apply (non-toxic) soil stabilizers on all unpaved access roads, parking areas, and staging areas at construction sites in order to insure proper control of blowing dust for the duration of the project. Watering on public streets shall not occur. Streets shall be cleaned by street sweepers or by hand as often as deemed necessary by the Town Engineer, or at least once a day. Watering associated with on-site construction activity shall take place between the hours of 8 a.m . and 5 p .m . and shall include at least one (1) late-afternoon watering to minimize the effects of blowing dust. All public streets soiled or littered due to this construction activity shall be cleaned and swept on a daily basis during the workweek to the satisfaction of the Town. Demolition or earthwork activities shall be halted when wind speeds (instantaneous gusts) exceed twenty-five (25) miles per hour (MPH). All trucks hauling soil, sand, or other loose debris shall be covered. 36 . CONSTRUCTION ACTIVITIES: All construction shall conform to the latest requirements of the CASQA Stormwater Best Management Practices Handbooks for Construction Activities and New Development and Redevelopment, the Town's grading and erosion control ordinance, and other generally accepted engineering practices for erosion control as required by the Town Engineer when undertaking construction activities. 37. SITE DRAINAGE: Rainwater leaders shall be discharged to splash blocks. No through curb drains will be allowed. Any storm drain inlets (public or private) directly connected to public storm system shall be stenciled/signed with appropriate "NO DUMPING-Flows to Bay" NPDES required language. On-site drainage systems for all projects shall include one of the alternatives included in section C.3 .i of the Municipal Regional NPDES Permit. These include storm water reuse via cisterns or rain barrels, directing runoff from impervious surfaces to vegetated areas and use of permeable surfaces. If dry wells are to be used they shall be placed a minimum of ten (1 0) feet from the adjacent property line and/or right-of-way. No improvements shall obstruct or divert runoff to the detriment of an adjacent, downstream or down slope property. 38. SILT AND MUD IN PUBLIC RIGHT-OF-WAY : It is the responsibility of Contractor and homeowner to make sure that all dirt tracked into the public right-of-way is cleaned up on a daily basis. Mud, silt, concrete and other construction debris SHALL NOT be washed into the Town's storm drains . 39. GOOD HOUSEKEEPING: Good housekeeping practices shall be observed at all times during the course of construction. All construction shall be diligently supervised by a person or persons authorized to do so at all times during working hours. The storing of goods and/or materials on the sidewalk and/or the street will not be allowed unless an encroachment permit is issued by the Engineering Division of the Parks and Public Works Department. The adjacent public right-of-way shall be kept clear of all job related dirt and debris at the end of the day. Dirt and debris shall not be washed into storm drainage facilities. The storing of goods and materials on the sidewalk and /or the street will not be allowed unless an encroachment permit is issued . The Applicant's representative in charge shall be at the job site during all working hours. Failure to maintain the public right-of-way according to this condition may result in penalties and/or the Town performing the required maintenance at the Applicant's expense. 40. COVERED TRUCKS: All trucks transporting materials to and from the site shall be covered . N:\DEV\CO N DITIONS\20 16\0 ak Grove 52.docx This Page Intentionally Left Blank 52 Oak Grove Avenue -PROJECT DATA EXISTING CONDITIONS PROPOSED PROJECT REQUIRED/ PERMITTED Zoning district R-1 :8 same - Land use single family residence single family residence - General Plan Designation low density residential same - Lot size (sq. ft.) 11,426 11 ,426 8,000 sq. ft. minimum Exterior materials: • sid ing stucco hardi siding & fiber - cement board shingle • trim hardie plank fiber - cement board painted • windows milgard ultra fiberglass - • roofing composition roof - Setbacks (ft.): • front 25 25 2 5 feet minimum • rear (park) 20 20 20 feet minimum • side, east (address) 21 ft-10 in 21 ft-10 in (27 ft-3 in 8 feet minimum for new second floor) • side, west (park) 9 ft-11 in 9 ft-11 in (10 ft-6 in for 8 feet minimum new second floor) • side, north (address) 67 ft-7 in 67 ft-7 in (86 ft-3 in 8 feet minimum for new second floor) Maximum height (ft.) 16 ft-1 in 26 ft-6 in 30 feet maximum Building coverage(%) 2375 (20.8 %) 2443 (21.4 %) 40 % maximum Floor Area Ratio (%) • first floor 1915 1983 - • second floor -1148 .5 - EXHIBIT 4 • house total 1915 3131.5 3412 sq. ft. maximum • garage 368 368 937 sq. ft . maximum Parking Existing 2-car garage Existing 2-car garage two spaces minimum Tree Removals -None proposed canopy replacement N:IDEV\JENNIFER A\PROJECfSIARCHITECTURESITE\OAK GROVE\SFRDATA·R·l·8.DOC J.KRETSCHMER I ARCHITECT March 14,2016 101 Old Blossom Hill Road Los Gatos, CA 95032 Re: Justification letter for 52 Oak Grove Ave . Planning Division Town of Los Gatos 110 E. Main Street Los Gatos, CA 95030 408-354-6872 Dear Planning Staff, ph 408.221 .0771 jen@jkretschmer. com 1'1/\R I 4 2016 TOVv'N OF LCS GATO S PL,;lxN ;:,-3 !.):VISI ON The application for a Minor Residential Application has been submitted to you for a second story addition to an existing residence located at 52 Oak Grove Ave . This proposed second story addition will change the design appearance of the home. The property owners like simple, traditional, American homestyles and want an uncomplicated roof structure design as well. We are proposing a home in the National style, that is a composite of 1-House and Gable Front and Wing (Field Guide to American Houses). This style, which is sometimes confused with Victorian era homes as it is similar in overall forms, was revived in the early 201 h Century with the Craftsman movement. It is a style that continues to be popular today and is compatible with existing homes in Los Gatos . The existing neighborhood is comprised of predominantly single story homes but there are a few two story homes nearby, too. The predominant style is Ranch. However, changes to many of the facades of the homes have created an ecclectic neighborhood. Stone, stucco , siding, brick, board and batten can all be seen on this one street. (See our submitted How to Read Your Neighborhood workbook) There are two, two-story homes that are close enough to be on our streetscape drawing . One harks elements of the Tudor style and the other is Contemporary with traditional forms but the .use of contemporary finishes . Our clients' home is located at the very end of the cul-de-sac and set far back from its neighbors because of the shape of the lot. The rear (South) and West sides of the home are adjacent to open space and the Los Gatos Creek Trail. The trail is located below the home and the home is barely visible from the trail. A second story addition will not impact sunlight on any neighbor's property. Please Shadow Study, page Al.l. No neighbor views should be obstructed. The closest neighbor's house is oriented in such a position that views from the primary structure will not be blocked. lf you have any questions or concerns regarding this letter and our application, please contact me directly . Regards , Jennifer Kretschmer, AlA Principal Architect J. Kretschmer, Architect :E XHIBIT 5 This Page Intentionally Left Blank Jennifer Armer C o mmunity Develo pment Department, 110 E. Main Street Los Gatos, CA 95030 May 18,2016 52 Oak Grove Avenue Arborist Report Dear Jennifer: Deborah Ellis, MS Consult ing Arborist & Horticultu r ist Service since 1984 I have reviewed the plan set that you sent dated May 12, 201 6 and visited the site today. There is only on e tree on site that should be impacted by thi s project, which includes the addition of a second floor near the tree. This tree is labeled as #2 in the photo below. It is a 38-inch trunk diameter valley oak. There are three other trees on or adjac ent to the site that I recommend receive tree protection fencing however, so that materials, equipment and miscellaneous work that is involved in the remodeling will not impact these trees . The reason for this is that trees are magnets for things to be stored and dumped around them, particularly right up against the trunk. An aerial map sh o w ing the loc ation of all trees disc usse d in this report is on page 2. Tree desc riptions are on pages 3 -6. Re commendatio ns are o n page 7. Because there are o nly a few trees and not muc h is g oing on around them I have prepared this short report instead of a more detailed report . PO Box 3714 , Saratoga, CA 95070. 408-725-1357. decah@pacbell.net. http://www.decah.com. Page 1 of 8 EXHIBIT 6 Deborah Ellis , MS Consulting Arborist & Horticulturist Service siuce 1984 Aerial map of site, with subject trees labeled. Trunk locations are appro x imate. PO Bo x 3714, Saratoga, CA 95070. 408-725-1357. decah@pacbel l.net. http://www.decah .co m. Page 2 of 8 Deborah Ellis, MS Consulting A r borist & Horti culturist TREE QESCRIPTI ONS Tree#· 1 Species: Quercus agrifolia Common Name: coast live oak Trunk DBH : 28 inches Tree size {height x canopy spread, estimated): 45x45 feet Condjtjon : Vigor: Fa ir/Good Structure: Fair Preservation Suitability: Fair/Good Estimated Value : $13,900 Expected Impact of Construction : Low Sen1ice since 1984 There is a good photo of the canopies of oaks #1 and 2 on page 1. The photo above shows the lower trunks of both trees and their proximity to the existing house. viewed from the south . Oak #2 is quite close to the house and tree protection fencing will need to be a few feet from the trunk (between the trunk and the house) in orqer for remodeling work to proceed . Because of this, pl y wood should be placed on the ground surface between the fencing and the house, to reduce soil compaction relative to the tree. PO Box 3714 , Saratoga, CA 95070. 408-725-1357. decah@pacbell.net. http://www.decah.com. Page 3 of 8 Tree#: 2 Species : Quercus lobata Common Name: valley oak Trunk DBH : 38 inches Tree size: 55x50 feet Condjtjon: Vigor: Fair/Good Structure: 60 Fair Preservation Suitability: Fair/Good Estimated Value: $40 ,600 Expected Impact of Construction: Low/Moderate Deborah Ellis, MS Consulting Arborist & Horticultu r i st Service since 1984 Notes: The tree has been previously pruned to clear the existing house roof. C urrently branches are at least 20 feet above the ground facing the house . Some minor clearance pruning may be necessary to bu il d the second story addition. I suggest erecting story posts to show the roof location and then pruning the tree to allow for 5 feet or so of clearance beyond the story posts . Th is photo views the tree from the N orth, showing how t he tree has a lready been pruned back from the existing house roof. Some addi t io nal clearance pruning may be necessary, but it will probably be minor. Story posts wil l help us to determine how much pruning is necessary . PO Bo x 3714, S aratoga, CA 9 5070. http:/ /www .decah .com. Pa ge 4 of 8 Tree#: 3 Species : Quercu s a grifolia Common Name: coast l ive oak Trunk DBH: 28 inches Tree size: 45x 35 feet Condjtjon: Vigor: Good Structure: Un certain Preservation Suitability: Un certain Estimated Value $13 ,900 Expected Impact of Construction : Low Deborah Ellis, MS Consulti ng Arborist & Horti culturist Service sin ce 1984 Notes: Trunk diameter is estimated due to ivy growing u p trunk and into branches . Ivy should be removed from tree and tree re-evaluated by arborist. Coast live oak #3, viewed from the west. Thi s __;;.~:i:J..:=~~:.:::...=:~~:;:;~~~~ tree is in the southeast corner of the property. PO Box 3714, Saratoga, CA 95070. 408-725-1357. decah@pacbell.net. http:/ /www.decah .com. Page 5 of 8 Tree#: 4 Species: Aescu/us californica Common Name: California buckeye Trunk DBH: 12 inches Deborah Ellis, MS Consulting Arborist & Horticulturist Ser11ice since 1984 Tree size (height x canopy spread, estimated): 20 x 25 feet Condjtjon: Vigor: Good Structure: Fa ir Preservation Suitability: Fair Estimated Value $1880 Expected Impact of Construction : Low Notes: tree is growing in wildland area to the south of the project site , but low hanging branches of the tree overhang the site by about 15 feet and should be fenced off. If the branches are in the way, additional clearance can be obtained using proper pruning methods. Kind of hard to see what is going on through all the foliage, but th is tree overhangs the site low and by about 15 feet. The overhanging branches should be fenced off. PO Box 3714, Saratoga, CA 95070. 408-725-1357 . decah@pacbell.net. http:/ /www.decah.com. Page 6 of 8 Deborah E lli s, MS Consulting Arborist & Horticulturist Service since 1984 RECOMMENDATIONS: l) Type l Tree protection fencing should be erected for each of the four trees described, fencing off as much of the dripline of the tree overhanging the project as possible with the following exception: a) Oak #2 is quite c lose t o the house and tree protection fencing w ill need to be a few feet from the trunk (between the trunk and the house) in order for remodeling work to proceed. Therefore three-quarters or l-inch thick plywood sheets should also be placed on the ground surface between the fencing and the house, to reduce soil compaction relative to the tree. 2) The Town of Los Gatos Tree Protection Directions are attached and must be included in the final project plan set. The Directions provide tree protection fencing specifications and other information related to existing tree protection. 3) Erect story posts adjacent t o oak #2, t o define the size and location of the second story addition roof. With story posts in place prune the tree to allow for 5 feet or so of clearance beyond the story posts. Pruning shall be performed by a qualified tree service using current arboricultural industry pruning standards 1• 4) Since there are native oaks on the property I have attached an informational pape r for the owners , Living among th e Oaks. 1 Qualified Tree Setvice : A tree service with a supervisin g arborist who has t he minimum certification level of I SA (International Society of Arboriculture) Ce rtifi ed Arborist for at least 5 years, in a supervisory pos it ion on the job site during execution of the tree work. The tree service shall ha ve a State of California Contractor's li cense for Tre e Service (C61-D49) and provid e proof of Workman's Compensation and General Liability Insurance. The perso n(s) performing the tree work must underst and and adhere to t he most current of the foll owing arboricultural industry tree ca re standards: • Best Management Practices. Tree Pruni ng . International Society of Arboriculture, PO Box 3129, Champaign, IL 6182 6-3 129. 217-355-9411 • • htt p:/ /www.decah.com. Page 7 of 8 Deborah Elli s, MS Consulting Arborist & Horticulturist Service s in ce 1984 ****************************** I certify that the information contained in this report is corre c t to t he best of my knowledge, and that this report was prepared in good faith. Thank you for the opportunity to p rovid e service again. Pleas e call me if you have questions or if I c an be o f further assistan ce. IJ:kLUL Deborah Elli s, MS. Consulting Arborist & Hortic ulturist Certified Professional Horticulturist #30022 ASCA Registered Consulting Arborist #305 I.S.A. Board Certified Mast er Arborist WE-457B I.S.A. Tree Risk Assessment Qualified ENCLOSURES: • Town o f Los Gatos Tree Protection Directions • Living among the Oaks -a Management Guide f or Landowners. Johnson . Un iversity of California Cooperative Extension , Natural Re so urces Pro g ram. February 201 1 Revision. Please Note : the trees that are discussed in this report received a Level 2 Basic Evaluation on. This type of evaluation is a brief visual evaluation of the tree from the ground , without climbing in to the tree or performin g detailed tests such as extensive digging , boring or removing samples. The tree is viewed by walk in g all around it, unless this is not possible. This type of evaluation is an initial screening of the tree after which the evaluator may recommend that additional , more detailed examination(s) be performed if deemed necessary. A risk evaluation was not performed on the trees. Other trees on the subj ect property or ne ighbor ing properties that were not evaluated. The measures noted within this report are designed to ass ist in the protection and preservation of the trees mentioned herein, should some or all of those trees remai n, and to help in their short and long term health and longevity. This is not however ; a guarantee t hat any of these trees may no t suddenly or eventually decline, fail, or die, for whatever reason. Because a significant portion of a tree's roots are usually far beyond its dripline , even trees that are well protected during constr uction often decline , fail or die. Because there may be hidden defects within the root system , trunk or branches of trees , it is poss ible that trees with no obvious defects can be subject to failure without warni ng. The current state of arboricultural science does not guarantee the accurate detection and prediction of tree defects and the r isks associated with trees. There will always be some level of risk associated with trees, particularly large trees. It is impossible to guarantee the safety of any tree. Trees are unpredictable. PO Bo x 3714, Saratoga, CA 95070. 408 -725-13 57. decah@pacbell.net . http://www .decah .com. Page 8 of 8 CllG CANNON DESIGN:· GROUP.· May 5, 2016 M s. Jennifer .-\rmer Community Developme nt Department Town of Los Gatos 11 0 E . Main Street Los Gatos, C-\ 95031 RE: 52 Oak Grove Avenue Dear Jennifer: ARCHITECTURE PLANNING URBAN DESIGN I reviewed the drawings, and visi ted th e si te. My comments and recommendations are as follows: Neighborhood Context T h e site is located at the end of a cul-d e-sac lin ed with traditio n al styled single famil y homes. The parcel backs up to a heavily wooded area. Photographs of the neighborhood are shown on t11e fo llowing page. 700 LARKSPUR LANDING C IRCLE. SU ITE 199 . LARKSPUR. CA. 94939 EXHIBIT 7 TEL: 4 1 5.33 1.3795 CDGPLAN@PACBELL.NET Existing house on the site House to the immediate left Nearby house on Oak Grove Avenue Grove Avenu e CANNON DESIGN GROUP House to the immediate right 52 Oak Grove Avenue Design Review Com menrs May 5. 2016 Page 2 Nearby house on Oak Grove Avenue Nea Avenue 700 LARKSPUR LANDING CIRCLE . SU ITE 199 . LARKSPUR . CA . 94939 Conce rns and Iss u es 52 Oak Grove Ave n ue Des ign Review Comments Ma y 5. 2016 Page 3 J was initially conce rned that the two -story fro nt facade might be out of place on thi s cul -d e-sac, but havin g looked at the design more ca refully, I belleve th at its s trong, traditional architectu ral sty le and relatively sm all scale would m ake this a positive addi tion to the n eighbo rho od with a few m o difi cations. T here are m an y exa mples in Los Gatos o f thi s tw o -s tory archi tec tural style well in teg rated into th e context of one-story neig hborhoods. Specific concerns include the following 1. The large single wall p la n e at th e front of the house seem s roo large for thi s n eighborh ood . 2. The jamb and trim between p aired windows seems too wid e. ,.----!Jamb between windows seems too wide Large single wall plane seems to large for this neighborhood Recommend ati o n s 1. Recess th e second floor wall p lane o n d1e front elevation to provid e som e facad e ll rti culation . 2. Reduce the wid th of d1e jamb and trim be tween grouped windows -see example pho tos on th e fo ll owing page. 3. .-\dd p lanter b oxes o r pot sh elves to provide architec tural tex ture and d e rail. Reduce w idth of jamb and .------....... --!trim between windows See example photos Add planter boxes or pot shelves to provide architectural detail CAN 0 DESIG 1 GROUP 700 LARKSPUR LA 1DING CIRC LE . SUITE 199 . LARKSPUR. CA. 94939 52 Oak Grove Avenu e D es ign Review Comments Ma y 5. 20 16 Pa ge 4 Jetmi fer, please le t m e know if yo u h ave any question s, or if there arc other issu es tha t I did n ot address. Sincerely, C-\NNON D ES IGN GROUP Larry L. Cannon CAN NON DESIG GROU P 700 LARKSPUR LANDI G C IR C LE . SUITE 199 . LARK SPUR . CA . 94939 D1.0 DEMOLITION FLOOR PLAN, 50% CONTIGUOUS WALL AREA CALCULATIONS D1.1 DEMOLITION EXTERIOR ELEVATIONS, 50% CONTIGUOUS WALL AREA CALCULATIONS SCOPE OF WORK: STANDARD ABBREVIATIONS &and @ at C.L.centerline Ø diameter PLT plate #pound/number (E)existing (N)new AB anchor bolt AC asphaltic concrete AGG aggregate ALT alternate ALUM aluminum APPROX approximate ARCH architect ASB asbestos ASPH asphalt AVE avenue AVG average BB bulletinboard BD board BITUM bituminous BLDG building BLK block BVLD boulevard BM benchmark/beam CAB cabinet CB catch basin/chalkboard CEM cement CI cast iron CJ control joint CLG ceiling CLKG caulking CLR clear CNTR counter CO cleanout COL column CONC concrete CONN connection CONST contruction CONT continuous CORR corridor CTR center CYL cylinder DBL double DEPT department DF Douglas Fir/drinking fountain DIA diameter DIM dimension DISP dispenser DN down DS downspout DW dishwasher DWG drawing DWL dowel DWR drawer EA each EJ expansion joint EL elevation ELEC electrical ELEV elevator EMER emergency ENCL enclosure EP electric panelboard EQ equal EQUIP equipment EXIST existing EXP exposed EXT exterior FA fire alarm FD floor drain FDN foundation FE fire extinguisher FEC fire extinguisher cabinet FHC fire hose cabinet FIN finish FL floor FLASH flashing FLOUR flourescent FOC face of concrete FOF face of finish FOS face of stud FPRF fire proof FS full size FT foot/feet FTG footing FURN furnish FURR furring FUT future GA gauge GB grab bar GALV galvanized GL glass GRD grade GYP gypsum HB hose bib HC hollow core HD hot dipped HDWE hardware HDWD hardwood HM hollow metal HORIZ horizontal HR hour HT height HTG heating HTR heater ID inside diameter IN inches INT interior INSUL insulation JAN janitor JT joint KD kiln dried LAB lab LAM laminated LAV lavatory MAT material MAX maximum MC medicine cabinet MDF medium density fiberboard MECH mechanical MEMB membrane MET metal MFGR manufacture(r) MH manhole MIN minimum MIR mirror MISC miscellaneous MO masonry opening MOD module/modular MTD mounted MUL mullion NIC not in contract NO number NOM nominal NTS not to scale OC on center OD outside diameter OFF office OPNG opening OPP opposite PART partition PBO provided/supplied by owner PERP perpendicular PG plate glass PL property line PLYWD plywood PR pair PT pressure treated QT quarry tile R rise/radius RD roof drain REINF reiforce/reinforcing REF reference REFR refridgerator REQ required RESIL resiliant REV revision RM room RO rough opening RWD redwood RWL rain water leader SECT section SEL select SD soap dispenser SG sheet glass SH shelf SHT sheet SHWR shower SIM similar SND sanitary napkin dispenser SNR sanitary napkin recepticle SPEC specification SQ square SS stainless steel SSK service sink STD standard STL steel STRUCT structural SUSP suspend(ed) SYM symetrical TB towel bar TEL telephone TER terazzo T&G toungue & groove TOC top of curb TOP top of plate TP top of pavement TPD toilet paper dispenser TPG tempered plate glass TPH toilet paper holder TSCH toilet seat cover dispenser TV television TW top of wall TYP typical VENT ventilation VERT vertical VEST vestibule VGDF vertical grain Douglas Fir VOL volumn W/with WC water closet WD wood WF wide flange WIN window W/O without WP waterproof(ing) WSCT wainscot WT weight APN MAP TULLIS RESIDENCE 52 OAK GROVE AVE., LOS GATOS, CA TABLE OF CONTENTS A1.0 EXISTING AND PROPOSED SITE PLAN A2.0 A3.0 EXISTING FLOOR PLAN A4.0 EXISTING ROOF PLAN EXISTING EXTERIOR ELEVATIONS N.T.S. G1.0 N.T.S. COVER SHEET N E S W PROJECT INFORMATION OWNER: BOB AND ELEANOR TULLIS APN# 529-30-025 ZONING: R-1-8 TYPE V-B ; NON-SPRINKLERED OCCUPANCY GROUP: R3 PHONE: 408-823-2509 MAILING ADDRESS: 52 OAK GROVE AVE., LOS GATOS, CA 95030 A2.1 PROPOSED FIRST FLOOR PLAN REMODEL (E) RESIDENCE. ADDITION TO BACK OF RESIDENCE OF 68 SFT. RECONFIGURE FIRST FLOOR TO ACCOMODATE FAMILY ROOM. SECOND FLOOR ADDITION OF 1170 SF WITH 2 BEDROOMS, BATHROOM AND MASTER SUITE. A3.1 NEW EXTERIOR ELEVATIONS A4.1 PROPOSED ROOF PLAN VICINTY MAP PROJECT SITE G1.0 GENERAL PROJECT REQUIREMNETS, COVER SHT. CONDITIONS OF APPROVAL PROJECT LOC. A1.1 SHADOW STUDY A1.2 STREET SCAPE A2.2 PROPOSED SECOND FLOOR PLAN (E) LOT AREA: 11426 S.F. EXISTING HOUSE AREA: 1915 S.F. (E) HOUSE IS SINGLE STORY PROPOSED 1ST FLR ADD: 68 S.F. (N) FIRST FLOOR EXIST + NEW : 1983 S.F. PROPOSED SECOND FLOOR ADD: 1148.5 S.F. TOTAL PROPOSED FLOOR AREA: 3131.5 S.F. (E) F.A.R.: .17 (N) F.A.R.: .27 MAX. ALLOWED F.A.R : .30 MAX. ALLOWED FLOOR AREA: 3412 S.F. EXISTING GARAGE: 368 S.F. EXISTING GARAGE F.A.R.: .032 MAX. ALLOWED F.A.R : .082 MAX. ALLOWED FLOOR AREA: 937 S.F. NO CHANGE TO GARAGE. BUILDING LOT COVERAGE EXISTING PROPOSED FIRST FLOOR: 1915 SQ. FT. GARAGE: 368 SQ. FT. TOTAL (E): 2375 SQ.FT. LOT: 11426 SQ. FT. TOTAL (N+E): 2443 SQ. FT. (E) LOT COVERAGE: .208 = 21% (N) LOT COVERAGE: .214 = 21% PLAY STRUCTURE: 32 SQ. FT. FIRST FLOOR (N+E): 1983 SQ. FT. GARAGE: 368 SQ. FT. PLAY STRUCTURE: 32 SQ. FT. COVERED PORCH: 60 SQ. FT. COVERED PORCH: 60 SQ. FT. LOT: 11426 SQ. FT. SURFACE AREA EXISTING PROPOSED PERVIOUS IMPERVIOUS 7625 SQ. FT.3801 SQ. FT. 3869 SQ. FT.7557 SQ. FT. : 4570 SQ. FT. MAX ALLOW. BUILDING COVERAGE: 40% A3.2 NEW EXTERIOR ELEVATIONS GARAGE INFO: GARAGE LOT COVERAGE: (E) GARAGE LOT COVERAGE: 368 S.F. MAX. ALLOWED LOT COVERAGE: 831 S.F. (FOR DETACHED ACCESSORY STRUCTURES) NET LOT AREA EXCLUDING SETBACKS=15% OF 5540 S.F. F.A.R. CALCULATION: APPLICABLE CODES: 2013 CALIFORNIA BUILDING CODE: PART 1 CALIFORNIA ADMINISTRATIVE CODE PART 2 CALIFORNIA BUILDING CODE, VOLUMES 1 & 2 PART 2.5 CALIFORNIA RESIDENTIAL CODE (NEW) PART 3 CALIFORNIA ELECTRICAL CODE PART 4 CALIFORNIA MECHANICAL CODE PART 5 CALIFORNIA PLUMBING CODE PART 6 CALIFORNIA ENERGY CODE PART 8 CALIFORNIA HISTORICAL BUILDING CODE PART 9 CALIFORNIA FIRE CODE PART 11 CALIFORNIA GREEN BUILDING STANDARDS CODE - CALGREEN, 1ST STATE-ADOPTED GREEN CODE PART 12 CALIFORNIA REFERENCED STANDARDS CODE AND UPDATED: 2012 INTERNATIONAL CODE FOR PROPERTY MAINTENANCE 2012 INTERNATIONAL EXISTING BUILDING CODE COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTIONEXHIBIT 8 NWES38" DIAMETER OAK TREE (E) TREE DRIP LINEREFRIGERATORALCOVEREFRIGERATORALCOVEREFRIGERATORALCOVE16'-9"11'-4 1/2"28'-1 1/2"14'-5 1/2"19'-9 1/2" 34'-3"19'-2" 8'-9"26'-3 1/2" 1'2'10'5'20'-2"18'-3"18'-2"42'-10"5'-2 1/2"9'-4"3'-5 1/2"14'-4 1/2"2'-8 1/2"4'-0"20'-2 1/2"CEILING HEIGHT 8'-0"CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0"RIDGE@ 11'SEE DEMOLITION ELEVATIONS, P. D1.1 FOR WALL AREA CALCULATIONS (E) PERIMETER: 238.4 LIN. FT. CONT. WALL PERMITER: 214.42 LIN. FT. (90%) LEGEND EXISTING WALLS TO REMAIN NEW WALLS NEW EXISTING (N) (E) REPLACE(R) ALL DIMENSIONS ARE FACE OF FINISH. LOCATION OF NEW 6"X14" VENTS LEGEND EXISTING WALLS TO REMAIN NEW WALLS NEW EXISTING (N) (E) REPLACE(R) ALL DIMENSIONS ARE FACE OF FINISH. LOCATION OF NEW 6"X14" VENTS EXISTING WALLS TO BE REMOVED CONTIGUOUS WALL LINE: STARTS HERE MAINTAIN ALL EXISTING INTERIOR WALL FINISH (LATH AND PLASTER OR GYP. BOARD) ON ALL WALLS IN THE CONTIGUOUS WALL LINE EXCEPT AT FIREPLACE. AT FIREPLACE, REMOVE TO SLAB BELOW SUB FLOOR FRAMING ON INTERIOR SIDE ONLY. REMOVE WINDOW. CONTIGUOUS WALL LINE (E) DEMOLITION FLOOR PLAN 1/4"=1'-0" 1'2'10'5' D1.0 (E) DEMOLITION PLAN COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTION A3.0 NORTH ELEVATION 1/4" = 1'-0" SOUTH ELEVATION 1/4" = 1'-0" EAST ELEVATION 1/4" = 1'-0" (E) STUCCO (E) STUCCO (E) STUCCO12'-0"16'-1"(E) ASPHALT SHINGLE ROOF (E) ASPHALT SHINGLE ROOF (E) ELEVATIONS(E) ELEVATIONS 12'-1"GRADE F.F. PLT. HT. (E) CALIFORNIA LIVE OAK TREE 42.5' HEIGHT (E) CANOPY GRADE F.F. PLT. HT. PLT. HT. GRADE F.F.14'-5 1/2"WEST ELEVATION 1/4" = 1'-0" (E) STUCCO (E) ASPHALT SHINGLE ROOF GRADE PLT. HT. F.F.14'-11 1/2"15'-9"11'-4"11'-4"11'-4"14'-4 1/2"12'-5"ALL CEILING HEIGHTS ARE 8'-0", TYPICAL ALL CEILING HEIGHTS ARE 8'-0", TYPICAL ALL CEILING HEIGHTS ARE 8'-0", TYPICAL ALL CEILING HEIGHTS ARE 8'-0", TYPICAL EAST ELEVATION GARAGE GARAGE BEYOND GRADE F.F. FENCE WEST ELEVATION GARAGE COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTIONDEMO ELEVATIONS D1.1 GROSS WALL = GROSS WINDOWS/DOORS = NET WALL = DEMO = TOTAL WALL REMAINING = 407.4 SQ. FT. 104 SQ. FT 303.4 SQ. FT. 0 SQ. FT. 303.4 SQ. FT. (100%) GROSS WALL = GROSS WINDOWS/DOORS = NET WALL = TOTAL WALL REMAINING = 515 SQ. FT. 62.5 SQ. FT 452.5 SQ. FT. 452.5 SQ. FT. (100%) GROSS WALL = GROSS WINDOWS/DOORS = NET WALL = DEMO = TOTAL WALL REMAINING = 484.9 SQ. FT. 64 SQ. FT 363 SQ. FT. 158 SQ. FT. 205 SQ. FT. (56.5%) GROSS WALL = GROSS WINDOWS/DOORS = NET WALL = DEMO = TOTAL WALL REMAINING = 583.5 SQ. FT. 71 SQ. FT 512.5 SQ. FT. 40.5 SQ. FT. 472 SQ. FT. (91.4%) WINDOW 32 SFT WINDOW 4.5 SFT WINDOW 4.5 SFT DOOR 38 SFT WINDOW 9 SFT WINDOW 9 SFT WINDOW 25 SFT WINDOW 6 SFT WINDOW 18.5 SFT WINDOW 6 SFT WINDOW 11.5 SFT WINDOW 11.5 SFT WINDOW 6 SFT DOOR 40 SFT WINDOW 18 SFT DEMO 158 SFT WINDOW 8 SFT WINDOW 12.5 SFT DOOR 41.5 SFT DEMO 40.5 SFT GROSS WALL = GROSS WINDOWS/DOORS = NET WALL = DEMO = TOTAL WALL REMAINING = 28 SQ. FT. 0 SQ. FT 28 SQ. FT. 0 SQ. FT. 28 SQ. FT. (100%) EXTERIOR WALL (NOT SHOWN) GROSS WALL = GROSS WINDOWS/DOORS = NET WALL = DEMO = TOTAL WALL REMAINING = 2063.3 SQ. FT. 301.5 SQ. FT 1717.3 SQ. FT. 198.5 SQ. FT. 1557.8 SQ. FT. (90.7%) TOTAL WALL AREAS CONTIGOUS WALL AREA 142 SFT CONTIGUOUS WALL AREA 583 SFT 45° ANGLE NOTED IN SIDE ELEVATIONS DE COMISSION CHIMNEY. REMOVE TO WALL. DO NOT EXPOSE WALL FRAMING 25'-0" FRO N T SETB A C K 8'-0" SIDE SETBACK 8'-0" SIDE SETBACK20'-0"REAR SETBACKSIDESETBACK1/8" = 1'-0"NWESEXISTING SITE PLAN (E) AND (N) SITE PLAN DRIVEWAY OAK GROVE AV 25'-0" FRO N T SETB A C K 8'-0" SIDE SETBACK 8'-0" SIDE SETBACK20'-0"REAR SETBACKSIDESETBACK1/8" = 1'-0"PROPOSED SITE PLAN DRIVEWAY NO CHANGE OAK GROVE AV (E) GARAGE (E) TREE 38" DIA. CALIFORNIA LIVE OAK (E) OAK TREE 380" DRIPLINE (E) TREE 25" DIA. CALIFORNIA LIVE OAK (E) TREE 25" DIA. CALIFORNIA LIVE OAK 250" DRIPLINE (E) OAK TREE A1.0NWES32'-3"59'-10"18'-4 1/2" 13'-10 7/8" PARKING (E) HOUSE REMOVE ROOF WALLS TO REMAIN (E) TREE 25" DIA. CALIFORNIA LIVE OAK (E) GARAGE 1'2'10'5' PARKING NO CHANGE (E) GRADE NO CHANGE (E) TREE 38" DIA. CALIFORNIA LIVE OAK 380" DRIPLINE 1'2'10'5' (E) DECK (E) DECK TO REMAIN (E) PLAY STRUCTURE (E) PLAY STRUCTURE (E) TREE 23.5" DIA. CALIFORNIA LIVE OAK 235" DRIPLINE (E) TREE 23.5" DIA. CALIFORNIA LIVE OAK 235" DRIPLINE (E) CANOPY (E) TREE 25" DIA. CALIFORNIA LIVE OAK (E) CANOPY (E) CANOPY (E) CANOPY (E) CANOPY (E) CANOPY (E) CANOPY (E) CANOPY (E) CANOPY (E) CANOPY PROVIDE PROTECTIVE FENCING IN TPZ ZONE AS PER SECTION 29.10.1005 8'-0" (E) FENCE (E) FENCE (E) FENCE (E) FENCE (E) FENCE (E) FENCE (E) FENCE DN (E) FENCE COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTION SHADOW STUDY 9AM WINTER 1/32"=1'-0"SHADOW STUDY 12PM WINTER 1/32"=1'-0"SHADOW STUDY 3PM WINTER 1/32"=1'-0" SHADOW STUDY 9AM SUMMER 1/32"=1'-0"SHADOW STUDY 12PM SUMMER 1/32"=1'-0"SHADOW STUDY 3PM SUMMER 1/32"=1'-0"N E S W N E S W N E S W N E S W N E S W N E S W COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTIONSHADOW STUDY A1.1 ONE STORY ONE STORYONE STORY ONE STORYONE STORY ONE STORYONE STORY ONE STORYONE STORY ONE STORYONE STORY ONE STORY A1.2 ACROSS THE STREET VIEW Scale: 1/16" = 1'-0"4 COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTIONPROPOSED PROJECT SIDE OF STREET Scale: 1/16" = 1'-0"2 END OF CUL-DE SAC, FRONT ELEVATION Scale: 1/16" = 1'-0"3 52 OAK GROVE AVE56 OAK GROVE AVE OPEN SPACE 62 OAK GROVE AVE66 OAK GROVE AVE66 OAK GROVE AVE70 OAK GROVE AVE76 OAK GROVE AVE80 OAK GROVE AVE OPEN SPACE 52 OAK GROVE AVE 46 OAK GROVE AVE 42 OAK GROVE AVE 40 OAK GROVE AVE OAK GROVE AVENUE 52 56 62 66 70 76 8040 4246 OPEN SPACE OPEN SPACESINGLE STORYSINGLE STORY SINGLE STORY SINGLE STORY SINGLE STORY SINGLE STORY SINGLE STORY TWO STORY TWO STORY (N) COMPOSITION ROOF CERTAIN TEED LANDMARK TL REFRIGERATORALCOVEREFRIGERATORALCOVEREFRIGERATORALCOVEKITCHEN DINING FOYER BREAKFAST ALCOVE FAMILY ROOM (E) BEDROOM OFFICE (N) BATH (E) BATH WINE FRIDGE STORAGE UNDER STAIR SINK RANGE PANTRY 4'-8"X8'-2"BUILT-INFLAT CEILING UP FRIDGE (N) F.P. FRONT ELEVATION 1/8" = 1'-0" FLOOR PLAN 1/8" = 1'-0" EXISTING=GRAY EXISTING=GRAY STREET MAP 1" = 50' STREETSCAPE CROSS SECTION 25.5' 15'26'17.25'16.5'17' 25.5' 16'18' 19' NWES38" DIAMETER OAK TREE (E) TREE DRIP LINEREFRIGERATORALCOVEREFRIGERATORALCOVEREFRIGERATORALCOVE16'-9"11'-4 1/2"28'-1 1/2"14'-5 1/2"19'-9 1/2" 34'-3"19'-2" 8'-9"26'-3 1/2" 1'2'10'5'20'-2"18'-3"18'-2"42'-10"5'-2 1/2"9'-4"3'-5 1/2"14'-4 1/2"2'-8 1/2"4'-0"20'-2 1/2"CEILING HEIGHT 8'-0"CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0"RIDGE@ 11'SLOPES TO 8' PLATE A2.0 MASTER BEDROOM 18'-2"X14'-'9" BEDROOM 1 12'-2"X12'-3" BEDROOM 2 14'-9"X12'-3"BATH 1 7'-0"X8'-1" DINING 15'-6"X11'-0" LIVING 13'-4"X23'-8" ENTRY FOYER 10-0"X7'-3" KITCHEN 13'-6"X15'-9" BATH 2 8'-4"X5'-6" GARAGE 17'-6"x19'-5" EXISTING FLOOR PLAN 1/4" = 1'-0" (E) FLOOR PLAN 6'-0"MASTER BATH 10'-8"X8'-1" (E) WOOD DECK 703 SQ. FT. CEILING HT 10'-0" SLOPES TO 8' PLATE COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTION 8'-0"3'-11"PROPOSED FIRST FLOOR PLAN 1/4" = 1'-0"NWES(N) KITCHEN 17'-2" x 15'-7" (E) DINING FOYER 9'-9" X 6'-8" (N) BREAKFAST ALCOVE (N) FAMILY ROOM 13'-2" X 20'-1" (E) BEDROOM NO WORK OFFICE 15'-0: X 13'-9" (N) BATH 6'-0" X 8'-6" (E) BATH NO WORK (N) FLOOR PLAN WINE FRIDGE (N) STAIR SINK RANGE BUILT-INUP FRIDGE (N) GAS (FP) APPLIANCE (N) WINDOW @ (E)6'-8"3'-10 1/2"7'-4 1/2"6'-0"2'-5"6'-3"5'-8" 8'-11"5'-6"3'-4" 4'-5"ALIGN (E) AND (N) WALL ALIGN (E) AND (N) WALLA2.1 1'2'10'5' 38" DIAMETER OAK TREE (E) TREE DRIPLINE 34'-3"19'-2" KEEP EXT. OF FIREPLACE16'-7 1/2"11'-6"28'-1 1/2"40'-8"8'-9"(E)CLOSETREMOVE SEAT20'-2"18'-3" (E) WOOD DECK 635 SQ. FT. SEE SITE PLAN FOR TPZ (E) GARAGE 14'-9"X12'-3" 15'-6"X11'-0" 8'-4"X5'-6" 12'-6" x 16'-6"43'-1"18'-2 1/2"2'-8"20'-2 1/2"14'-4 1/2"26'-3 1/2" 11'-6 1/2" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 8'-0" CEILING HEIGHT 17'-0" CEILING HT 10'-0" SLOPES TO 8' PLATE SLOPES TO 8' PLATE FIRST FLOOR COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTION CLOSET 9'-9"X8'-2" BEDROOM 15'-6"X13'-0" BEDROOM 15'-0"X16'-6" HALL SECOND FLOOR: 1148.5 SQ. FT. BEDROOM 13'-0"X13'-8" SPA/TUB SHOWER 44"X60" LIN FIREPLACESHOE CLOSETCLOSETCLOSETM. BATH 18-0"X10'-9"5'-5 1/2"2'-4" DR2'-4" DRSKYLIGHT TOTAL FIRST AND SECOND FLOOR: 3153 3'-0" A2.2 PROPOSED SECOND FLOOR PLAN 1/4" = 1'-0" 5'-0"13'-0 1/2"2'-1" 15'-0 1/2"11'-9"5'-8 1/8"5'-0"3'-6 1/4"3'-0 3/4"3'-1 1/4" OPEN BELOW 30'-3"19'-2"28'-1 1/2"(E) TREE DRIPLINE 1'2'10'5' 40'-8"8'-9"NWES(N) 2ND FLOOR PLAN BATH ROOM 5' X 13'-0" CEILING HEIGHT 8'-0" ALL ROOMS 2ND FLR 19'-9 7/8"COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTION A3.0 NORTH ELEVATION 1/4" = 1'-0" SOUTH ELEVATION 1/4" = 1'-0" EAST ELEVATION 1/4" = 1'-0" (E) STUCCO (E) STUCCO (E) STUCCO12'-0"16'-1"(E) ASPHALT SHINGLE ROOF (E) ASPHALT SHINGLE ROOF (E) ELEVATIONS(E) ELEVATIONS 12'-1"GRADE F.F. PLT. HT. (E) CALIFORNIA LIVE OAK TREE 42.5' HEIGHT (E) CANOPY GRADE F.F. PLT. HT. PLT. HT. GRADE F.F.14'-5 1/2"WEST ELEVATION 1/4" = 1'-0" (E) STUCCO (E) ASPHALT SHINGLE ROOF GRADE PLT. HT. F.F.14'-11 1/2"15'-9"11'-4"11'-4"11'-4"14'-4 1/2"12'-5"ALL CEILING HEIGHTS ARE 8'-0", TYPICAL ALL CEILING HEIGHTS ARE 8'-0", TYPICAL ALL CEILING HEIGHTS ARE 8'-0", TYPICAL ALL CEILING HEIGHTS ARE 8'-0", TYPICAL EAST ELEVATION GARAGE GARAGE BEYOND GRADE F.F. FENCE WEST ELEVATION GARAGE COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTION (N) ELEVATIONS A3.1 (N) NORTH (FRONT) ELEVATION 1/4" = 1'-0" (N) FIBER CEMENT BOARD SHINGLE, TYPICAL @ GABLE ENDS (N) COMPOSITION ROOF CERTAIN TEED LANDMARK TL (N) MILGARD ULTRA FIBERGLASS WINDOWS, TYPICAL (N) HARDI SIDING 7" EXPOSURE (E) PAINTED DOORS25'-6"6'-3"GRADE PLT. HT. (E) CALIFORNIA LIVE OAK TREE 42.5' HEIGHT (E) CANOPY EAST ELEVATION 1/4" = 1'-0" (N) MILGARD ULTRA FIBERGLASS WINDOW (N) COMPOSITION ROOF CERTAIN TEED LANDMARK TL (N) HARDI SIDING 7" EXPOSURE, TYP (N) MILGARD ULTRA FIBERGLASS WINDOW GRADE (N) HARDIE PLANK FIBER CEMENT BOARD PAINTED TRIM PLT. HT. PLT. HT.16'-4"EAST ELEVATION GARAGE GRADE 26'-6"GRADE REUSE (E) FRENCH DOORS FROM KITCHEN F.F. F.F. F.F. F.F. (E) STUCCO ON GARAGE TO REMAIN SHED AWNING OVER WINDOW ALL CEILING HEIGHTS ARE 8'-0", TYPICAL FOR BOTH FIRST AND SECOND FLOOR. ALL CEILING HEIGHTS ARE 8'-0", TYPICAL FOR BOTH FIRST AND SECOND FLOOR. 8" POTSHELVES, TYP. (N) HARDIE PLANK FIBER CEMENT BOARD PAINTED TRIM, TYP. PLT. HT.COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTION (N) ELEVATIONS A3.2 WEST ELEVATION 1/4" = 1'-0" (N) COMPOSITION ROOF CERTAIN TEED LANDMARK TL (N) MILGARD ULTRA FIBERGLASS WINDOWS DECOMMISSION (E) CHIMNEY REMOVE TO WALL PLATE. DO NOT EXPOSE WALL FRAMING (N) MILGARD ULTRA FIBERGLASS WINDOWS (N) MILGARD ULTRA FIBERGLASS WINDOWS, TYP. (N) HARDI SIDING 7" EXPOSURE, TYP. GARAGE BEYOND F.F. F.F. PLATE PLATE 23'-1"WEST ELEVATION GARAGE GRADE28'-6"ALL CEILING HEIGHTS ARE 8'-0", TYPICAL FOR BOTH FIRST AND SECOND FLOOR. ALL CEILING HEIGHTS ARE 8'-0", TYPICAL FOR BOTH FIRST AND SECOND FLOOR. SOUTH ELEVATION 1/4" = 1'-0" (N) COMPOSITION ROOF CERTAIN TEED LANDMARK TL (N) MILGARD ULTRA FIBERGLASS WINDOWS (N) HARDI SIDING 7" EXPOSURE, TYP. (N) LA CANTINA ACCORDION DOORDS (N) HARDIE PLANK FIBER CEMENT BOARD PAINTED TRIM (N) MILGARD ULTRA FIBERGLASS WINDOWS F.F. (N) FIBER CEMENT BOARD SHINGLE F.F. PLATE 8'-0"8'-0"(E) STUCCO ON GARAGE TO REMAIN FENCE COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTION EXISTING ROOF PLAN 1/4" = 1'-0"NWES(E) ROOF PLAN A4.0 1'2'10'5' 3:12 3:12 5:12 5:12 3.6 : 123.6 : 123.6:123.6:122:123.6:12 3.6:12 (E) ROOF PLAN 38" DIAMETER OAK TREE SEE SITE PLAN FOR TPZ (E) TREE CANOPY 42.5' TREE HT COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTION PROPOSED ROOF PLAN 1/4" = 1'-0"NWESA4.1 1'2'10'5' (E)(E)(N)(N)(N)(N)(N)(N)(N)(N) (N) @ LOWER LEVEL (N)(N) (N)(N) (E)(E)(E)(E)(E ) (E)(E) 5:12 9:12 9:12 9:12 9:12 4:124:122:129:12 9:12 3:12 3:124:124:124:123:12 3:12 3:12 4:12 4:12 3.6:12 3.6:12 (N) ROOF PLAN 38" DIAMETER OAK TREE SEE SITE PLAN FOR TPZ (E) TREE CANOPY 42.5' TREE HT COPYRIGHT 2015 JENNIFER KRETSCHMER, AIAJ. KRETSCHMER, ARCHITECT. All drawings, specifications, and other documents, including those in electronic form, prepared by the architect are instruments of architectural service, and shall remain the property of the Architect. Use is restricted to the site for which they were prepared and for the purpose of constructing, using and maintaining this project only. These drawings may not be copied, revised, re-used or disclosed without the written consent of the Architect.101 OLD BLOSSOM HILL ROADLOS GATOS, CA 95032(408) 221-0771MEMBER AMERICAN INSTITUTE OF ARCHITECTSSTAMP 52 OAK GROVE AVE. LOS GATOS, CA 95030 MAY 12, 2016 J. KRETSCHMERARCHITECTTULLIS RESIDENCE NOT FOR CONSTRUCTION