Loading...
09 Attachment 1 - July 22, 2020 Planning Comission Staff Report, with Exhibits 1-16PREPARED BY: DIEGO MORA Assistant Planner Reviewed by: Planning Manager and Community Development Director 110 E. Main Street Los Gatos, CA 95030 ● (408) 354-6872 www.losgatosca.gov TOWN OF LOS GATOS PLANNING COMMISSION REPORT MEETING DATE: 07/22/2020 ITEM NO: 2 DATE: July 17, 2020 TO: Planning Commission FROM: Joel Paulson, Community Development Director SUBJECT: Consider an appeal of a Development Review Committee decision approving a request for demolition of an existing single-family residence, and construction of a new single-family residence on property zoned R-1:10. Located at 146 Robin Way. APN 532-12-015. Architecture and Site Application S-19-043. Property Owners: Mehrdad and Leila Dehkordi. Applicant: Gary Kohlsaat. Project Planner: Diego Mora. RECOMMENDATION: Deny the appeal of a Development Review Committee decision approving a request for demolition of an existing single-family residence, and construction of a new single-family residence on property zoned R-1:10 located at 146 Robin Way. PROJECT DATA: General Plan Designation: Low Density Residential Zoning Designation: R-1:10 Applicable Plans & Standards: General Plan, and Residential Design Guidelines Parcel Size: 13,112 square feet Surrounding Area: Existing Land Use General Plan Zoning North Residential Low Density Residential R-1:10 South Residential Low Density Residential R-1:10 East Residential Low Density Residential R-1:10 East Residential Low Density Residential R-1:10 ATTACHMENT 1 PAGE 2 OF 9 SUBJECT: 146 ROBIN WAY/S-19-043 DATE: JULY 17, 2020 N:\DEV\PC REPORTS\2020\2020 - Staff Reports and Exhibits\07-22-20\Item 2 - 146 Robin Way\Staff Report.docx CEQA: The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. FINDINGS: ▪The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. ▪As required by Section 29.10.09030(e) of the Town Code for the demolition of existing structures: 1.The Town’s housing stock will be maintained as the single-family residence will be replaced. 2.The existing structures have no architectural or historical significance, and are in poor condition. 3.The property owner does not desire to maintain the structures as they exist; and 4.The economic utility of the structures was considered. ▪The project is in compliance with the Residential Design Guidelines for single-family homes not in hillside residential areas. ▪The project is in compliance with the Residential Design Guidelines, and the applicant has further revised the design to respond to the concerns of the neighbors by lowering the height, replacing the flat roof parapet over the front bay with a gable, and changing the materials to warmer colors. The project is not the largest for FAR in the neighborhood, meets the objective standards of the zoning code, is a single-family transitional style compatible with the ranch houses in the neighborhood in terms of massing and scale, and was reviewed by the consulting architect and the applicant responded to the recommendations. CONSIDERATIONS: ▪As required by Section 29.20.150 of the Town Code, the considerations in review of an Architecture and Site application were all made in reviewing this project. ACTION: The decision of the Planning Commission is final unless appealed within ten days. PAGE 3 OF 9 SUBJECT: 146 ROBIN WAY/S-19-043 DATE: JULY 17, 2020 N:\DEV\PC REPORTS\2020\2020 - Staff Reports and Exhibits\07-22-20\Item 2 - 146 Robin Way\Staff Report.docx BACKGROUND: The subject property is located on the east side of Robin Way (Exhibit 1). The lot is approximately 13,112-square feet with an existing 2,466-square foot single-story residence with a 542-square foot garage. The immediate neighborhood contains one-story residences. On November 13, 2019, the applicant submitted an Architecture and Site application for the demolition of an existing single-family dwelling, construction of a new 3,737-square foot single- story residence, and a 508-square foot attached garage. The proposed project meets all technical requirements of the Town Code including parking, height, floor area, setbacks, and building coverage. On June 9, 2020, the Development Review Committee (DRC) approved the Architecture and Site application with an additional condition to address privacy concerns from the adjacent neighbor as detailed in the Discussion section of this report. On June 19, 2020, the decision of the DRC was appealed to the Planning Commission by the adjacent neighbor (appellant), due to concerns regarding privacy (Exhibit 14). PROJECT DESCRIPTION: A. Location and Surrounding Neighborhood The subject site is located on the east side of Robin Way (Exhibit 1). The surrounding properties are one-story single-family residences with Ranch Style architecture. B. Project Summary The applicant is proposing to construct a new 3,737-square foot one-story single-family residence with an attached 508-square foot garage (Exhibit 16). The proposed residence would be located within the area of the existing development. C. Zoning Compliance A single-family residence is permitted in the R-1:10 zone. The proposed residence is in compliance with the allowable floor area, height, setbacks, and on-site parking requirements for the property. PAGE 4 OF 9 SUBJECT: 146 ROBIN WAY/S-19-043 DATE: JULY 17, 2020 N:\DEV\PC REPORTS\2020\2020 - Staff Reports and Exhibits\07-22-20\Item 2 - 146 Robin Way\Staff Report.docx DISCUSSION: A. Architecture and Site Analysis The applicant is proposing to construct a new single-family residence with 3,737 square feet of living space, and a 508-square foot attached garage. The proposal also includes an attached open and covered loggia at the east end of the proposed residence which does not count towards floor area maximums. The maximum height of the proposed residence is 18 feet 1 inch, where a maximum of 30 feet is allowed. The proposed project materials include a standing seam metal roof, integral colored stucco, stone veneer siding, horizontal wood siding, and metal windows and trim. A color and materials board are included with this staff report (Exhibit 5). The applicant has provided a Written Description/Letter of Justification detailing the project (Exhibit 6). The project data sheet is attached as Exhibit 4 and includes additional information regarding the proposed project. B. Building Design The Town’s Consulting Architect reviewed the design of the proposed project within the neighborhood context to provide recommendations regarding the building design (Exhibit 7). The site is in a neighborhood of one-story Ranch Style homes. In the Issues and Concerns background section of the report, the Consulting Architect noted that the home fundamentally fits the Ranch Style, but identified issues with the Town’s Residential Design Guidelines. In the Recommendations section of the report, the Consulting Architect made the following recommendation(s) to address consistency with the Residential Design Guidelines: 1. Simplify the taller boxy elements on the front façade. 2. Limit the wood siding to accent locations (e.g., recessed entry, rear patio and right-side pop out). 3. Select a less prominent garage door compatible with the Ranch Style of the home and the immediate neighborhood. 4. Select a roof material more similar to other homes in the immediate neighborhood. 5. Use wood or other non-metal windows with traditional jamb dimensions. 6. Use wood trim at all windows and doors. 7. Simplify the wood pop up and roof on the rear façade and right-side elevation. The applicant revised the project to incorporate the Consulting Architect’s recommendations prior to the May 19, 2020 DRC public hearing (Exhibit 9). PAGE 5 OF 9 SUBJECT: 146 ROBIN WAY/S-19-043 DATE: JULY 17, 2020 N:\DEV\PC REPORTS\2020\2020 - Staff Reports and Exhibits\07-22-20\Item 2 - 146 Robin Way\Staff Report.docx DISCUSSION (continued): Following the May 19, 2020 DRC hearing, the applicant further revised the design to respond to the concerns of the neighbors by lowering the height, replacing the flat roof parapet over the front bay with a gable, and changing the materials to warmer colors prior to DRC approval. C. Neighborhood Compatibility The immediate neighborhood is made up of one-story single-family residences. Based on Town and County records, the residences in the immediate area range in size from 1,973- square feet to 3,967-square feet. The floor area ratios range from 0.139 to 0.307. The proposed residence would be 3,737-square feet with a floor area ratio of 0.285. Pursuant to Town Code, the maximum allowable square footage for the 13,112-square foot lot is 3,738-square feet with a maximum floor area ratio of 0.285. The table below reflects the current conditions of the immediate neighborhood: Address Zoning House Garage Total Lot Size FAR Garage FAR No. of Stories 146 Robin Way (Ex.) R-1:10 2,466 542 3,008 13,112 0.130 0.047 1 146Robin Way (Prop.) R-1:10 3,737 508 4,245 13,112 0.285 0.039 1 106 Robin Way R-1:10 2,299 494 2,793 10,710 0.215 0.046 1 112 Robin Way R-1:10 2,411 430 2,841 7,866 0.307 0.055 1 118 Robin Way R-1:10 2,287 550 2,837 11,160 0.205 0.049 1 122 Robin Way R-1:10 2,821 600 3,421 14,627 0.193 0.041 1 126 Robin Way R-1:10 3,967 561 4,528 23,580 0.168 0.024 1 136 Robin Way R-1:10 2,445 561 3,006 16,758 0.146 0.033 1 140 Robin Way R-1:10 2,149 552 2,701 15,423 0.139 0.036 1 150 Robin Way R-1:10 2,178 400 2,578 14,308 0.152 0.028 1 156 Robin Way R-1:10 1,973 506 2,479 11,132 0.177 0.045 1 The proposed residence would not be the largest home in the immediate neighborhood in terms of square footage or FAR. The applicant reached out to surrounding neighbors during the review process and reported not receiving any initial concerns (Exhibit 15). D. Tree Impacts The Town’s Arborist prepared a report for the site and recommendations for the project (Exhibit 8). The project site contains one protected tree. The applicant is proposing to remove four fruit trees and one protected tree. The existing protected tree proposed for removal is a Fir tree located on the rear east corner of the property. PAGE 6 OF 9 SUBJECT: 146 ROBIN WAY/S-19-043 DATE: JULY 17, 2020 N:\DEV\PC REPORTS\2020\2020 - Staff Reports and Exhibits\07-22-20\Item 2 - 146 Robin Way\Staff Report.docx DISCUSSION (continued): If the project is approved, tree protection measures would be implemented prior to and during construction. Replacement trees would also be required to be planted pursuant to Town Code. E. Development Review Committee The DRC held a public hearing for the Architecture and Site application on May 19, 2020. Written public hearing notices were sent to surrounding property owners and occupants within 300 feet of the subject property. Several neighbors, including Robert Buxton, Gordon Yamate, Liz Crites, Lora Lee and Jim Zaky, and Mark Willey, submitted correspondence or spoke on the item. Mr. Yamate submitted correspondence voicing his support for the project. Other neighbors raised concerns about the compatibility of the project with the neighborhood in terms of size, scale, and design. The DRC continued the item to June 2, 2020 to allow the applicants to address neighbor concerns. On June 2, 2020 the item was continued to June 9, 2020. During the continuance, the applicant met with the neighbors and further revised the design to respond to the concerns by lowering the height, replacing the flat roof parapet over the front bay with a gable, and changing the materials to warmer colors. The story pole installation was revised and certified to represent the lowered height. At the June 9, 2020 DRC public hearing, several neighbors, including Gordon Yamate, Lora Lee and James Zaky, Liz Crites, and Robert Buxton spoke on the item. Mr. Yamate spoke to voice his support for the project. Ms. Crites and Mr. Buxton raised concerns related to architecture, mass, and scale compatibility. The Zaky’s raised concerns regarding views to the north, scale, and privacy impacts associated with the removal of apple trees and landscaping. The applicant agreed to a condition of approval to install an eight-foot fence and increased landscape screening for privacy on the south side, and Mr. Zaky confirmed he would be amenable to that condition; however, he did not feel it would fully address his concerns (Exhibit 13). The DRC found that the application was complete and in compliance with the Town Code and Residential Design Guidelines. Based on these findings and considerations, the DRC approved the proposed project, subject to the recommended conditions of approval (Exhibit 3). PAGE 7 OF 9 SUBJECT: 146 ROBIN WAY/S-19-043 DATE: JULY 17, 2020 N:\DEV\PC REPORTS\2020\2020 - Staff Reports and Exhibits\07-22-20\Item 2 - 146 Robin Way\Staff Report.docx DISCUSSION (continued): F. Appeal On June 19, 2020, the decision of the DRC was appealed to the Planning Commission by the adjacent neighbor, James Zaky (Exhibit 14). The specific reasons for the appeal are provided below, followed by analysis in italic font. “Secure commitment from applicant to address privacy concerns. The DRC proposed the applicant replace the existing 5’ fence w/an 8’ fence between 146:140 Robin Way. Both parties agreed in concept. We are requesting a formal commitment by the applicant.” The existing wood fence is six-feet tall and in conformance with Town Code sec. 29.40.0315, which states that fences may not exceed six feet in height with a one-foot lattice on top. Condition of approval 11 states that the south side fence shall not be less than eight feet in height; and screening shall be added to the satisfaction of the Community Development Director. The final Building permit will not be approved until the condition is met. G. Environmental Review The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. PUBLIC COMMENTS: Following the filing of the appeal the applicant and appellant have met. On July 14, 2020, the applicant reported having met with the appellant on July 9, 2020 to discuss the fence and screening. No update has been provided since July 14, 2020. At the time of this report’s preparation, the Town has not received any public comment. Certified story poles, and a project sign including the hearing date, contact information, project description, were installed on the site; and the written notice of the Development Review Committee public hearing was sent to neighboring property owners and occupants. Following the May 19, 2020 public hearing, the story pole installation was revised and certified to represent the lowered height proposed in response to neighbor concerns. Following the appeal, written notice of the Planning Commission hearing was sent to neighboring property owners and occupants, the story poles have remained in place, and the project sign has been updated to reflect the appeal hearing before the Planning Commission. PAGE 8 OF 9 SUBJECT: 146 ROBIN WAY/S-19-043 DATE: JULY 17, 2020 N:\DEV\PC REPORTS\2020\2020 - Staff Reports and Exhibits\07-22-20\Item 2 - 146 Robin Way\Staff Report.docx CONCLUSION: A. Summary The proposed project is in compliance with the Residential Design Guidelines and Town Code. The applicant has agreed to modify their proposal in an effort to address the privacy concerns of the adjacent neighbors. Conditions of Approval capture the proposed changes, specifically condition 11 (Exhibit 3). B. Recommendation Staff recommends that the Planning Commission take the following actions to deny the appeal, uphold the decision of the DRC, and approve the Architecture and Site application: 1. Find that the proposed project is categorically exempt pursuant to the adopted Guidelines for the implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures (Exhibit 2); 2. Make the required findings as required by Section 29.10.09030(e) of the Town Code for the demolition of a single-family residence (Exhibit 2); 3. Make the finding required by the Town’s Residential Design Guidelines that the project complies with the Residential Design Guidelines (Exhibit 2); 4. Make the required considerations as required by Section 29.20.150 of the Town Code for granting approval of an Architecture and Site application (Exhibit 2); and 5. Approve Architecture and Site application S-19-043 with the conditions contained in Exhibit 3 and development plans attached as Exhibit 16. C. Alternatives Alternatively, the Commission can: 1. Continue the matter to a date certain with specific direction; 2. Deny the appeal and approve the application with additional and/or modified conditions; 3. Grant the appeal and remand the application to the DRC with direction for revisions; or 4. Grant the appeal and deny the Architecture and Site application. EXHIBITS: 1. Location Map 2. Required Findings and Considerations 3. Recommended Conditions of Approval 4. Project Data Sheet 5. Color and Materials board PAGE 9 OF 9 SUBJECT: 146 ROBIN WAY/S-19-043 DATE: JULY 17, 2020 N:\DEV\PC REPORTS\2020\2020 - Staff Reports and Exhibits\07-22-20\Item 2 - 146 Robin Way\Staff Report.docx EXHIBITS (continued): 6. Project Description and Letter of Justification, dated November 12, 2019 7. Consulting Architect’s Report, dated December 9, 2019 8. Town Arborist’s Report, dated January 16, 2020 9. Applicant’s response to Town’s Consulting Architect’s Report, dated January 6, 2020 10. Public Comments received prior to 10:00 a.m., Tuesday, June 9, 2020 11. May 19, 2020 Development Review Committee meeting minutes 12. June 2, 2020 Development Review Committee meeting minutes 13. June 9, 2020 Development Review Committee meeting minutes 14. Appeal of Development Review Committee received June 19, 2020 15. Applicant’s neighbor outreach efforts 16. Development Plans, received May 28, 2020 This Page Intentionally Left Blank KENNEDY R DCARDINAL LNLONGMEADOW DRROBIN WYOLDE DR VIA SANTA MARIASTONYBROOK RDBLUEBERRY HILL DRS KENNEDY RDNINA CT 146 Robin Way 0 0.250.125 Miles ° Update Notes:- Updated 12/20/17 to link to tlg-sql12 server data (sm)- Updated 11/22/19 adding centerpoint guides, Buildings layer, and Project Site leader with label EXHIBIT 1 This Page Intentionally Left Blank N:\DEV\PC REPORTS\2020\2020 - STAFF REPORTS AND EXHIBITS\07-22-20\ITEM 2 - 146 ROBIN WAY\EXHIBIT 2 - REQUIRED FINDINGS AND CONSIDERATIONS.DOCX PLANNING COMISSION – July 22, 2020 REQUIRED FINDINGS & CONSIDERATIONS FOR: 146 Robin Way Architecture and Site Application S-19-043 Requesting approval for demolition of an existing single-family residence and construction of a new single-family residence on property zoned R-1:10. APN 532-12-015. PROPERTY OWNER: Mehrdad & Leila Dehkordi APPLICANT: Gary Kohlsaat PROJECT PLANNER: Diego Mora FINDINGS Required finding for CEQA: ■The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. Required finding for the demolition of a single-family residence: ■As required by Section 29.10.09030(e) of the Town Code for the demolition of existing structures: 1.The Town's housing stock will be maintained as the single-family residence will be replaced. 2.The existing structures have no architectural or historical significance, and are in poor condition. 3.The property owner does not desire to maintain the structures as they exist; and 4.The economic utility of the structures was considered. Required Compliance with the Residential Design Guidelines: ■The project is in compliance with the Residential Design Guidelines for single-family homes not in hillside residential areas. ■The project is in compliance with the Residential Design Guidelines, and the applicant has further revised the design to respond to the concerns of the neighbors by lowering the height, replacing the flat roof parapet over the front bay with a gable, and changing the materials to warmer colors. The project is not the largest for FAR in the neighborhood, meets the objective standards of the zoning code, is a single-story transitional style EXHIBIT 2 N:\DEV\PC REPORTS\2020\2020 - STAFF REPORTS AND EXHIBITS\07-22-20\ITEM 2 - 146 ROBIN WAY\EXHIBIT 2 - REQUIRED FINDINGS AND CONSIDERATIONS.DOCX compatible with the ranch houses in the neighborhood in terms of massing and scale, and was reviewed by the consulting architect and the applicant responded to the recommendations. CONSIDERATIONS Required considerations in review of Architecture & Site applications: ■As required by Section 29.20.150 of the Town Code, the considerations in review of an Architecture and Site application were all made in reviewing this project. PLANNING COMISSION – July 22, 2020 CONDITIONS OF APPROVAL 146 Robin Way Architecture and Site Application S-19-043 Requesting approval for demolition of an existing single-family residence and construction of a new single-family residence on property zoned R-1:10. APN 532-12-015. PROPERTY OWNER: Mehrdad & Leila Dehkordi APPLICANT: Gary Kohlsaat TO THE SATISFACTION OF THE DIRECTOR OF COMMUNITY DEVELOPMENT: Planning Division 1.APPROVAL: This application shall be completed in accordance with all of the conditions of approval and in substantial compliance with the approved plans. Any changes or modifications to the approved plans and/or business operation shall be approved by the Community Development Director, DRC or the Planning Commission depending on the scope of the changes. 2.EXPIRATION: The approval will expire two years from the approval date pursuant to Section 29.20.320 of the Town Code, unless the approval has been vested. 3.OUTDOOR LIGHTING: Exterior lighting shall be kept to a minimum, and shall be down directed fixtures that will not reflect or encroach onto adjacent properties. No flood lights shall be used unless it can be demonstrated that they are needed for safety or security. 4.TREE REMOVAL PERMIT: A Tree Removal Permit shall be obtained for any protected trees to be removed, prior to the issuance of a building or grading permit. 5.EXISTING TREES: All existing trees shown on the plan and trees required to remain or to be planted are specific subjects of approval of this plan, and must remain on the site. 6.TREE FENCING: Protective tree fencing and other protection measures shall be placed at the drip line of existing trees prior to issuance of demolition and building permits and shall remain through all phases of construction. Include a tree protection plan with the construction plans. 7.TREE STAKING: All newly planted trees shall be double-staked using rubber tree ties. 8.FRONT YARD LANDSCAPE: Prior to issuance of a Certificate of Occupancy the front yard must be landscaped. 9.ARBORIST REQUIREMENTS: The developer shall implement, at their cost, all recommendations identified in the Arborist’s report. These recommendations must be incorporated in the building permit plans, and completed prior to issuance of a building permit where applicable. A Compliance Memorandum shall be prepared by the applicant and submitted with the building permit application detailing how the recommendations have or will be addressed. 10.WATER EFFICIENCY LANDSCAPE ORDINANCE: The final landscape plan shall meet the requirements of the Town of Los Gatos Water Conservation Ordinance or the State Water Efficient Landscape Ordinance, whichever is more restrictive. Submittal of a Landscape Documentation Package pursuant to WELO is required prior to issuance of a building EXHIBIT 3 permit. A review fee based on the current fee schedule adopted by the Town Council is required when working landscape and irrigation plans are submitted for review. A completed WELO Certificate of Completion is required prior to final inspection/certificate of occupancy. 11.SIDE YARD SCREENING: South side fence shall not be less than eight feet in height; and screening shall be added to the satisfaction of the Community Development Director. 12.SALVAGE OF BUILDING MATERIALS: Prior to the issuance of a demolition permit, the developer shall provide the Community Development Director with written notice of the company that will be recycling the building materials. All wood, metal, glass, and aluminum materials generated from the demolished structure shall be deposited to a company which will recycle the materials. Receipts from the company(s) accepting these materials, noting the type and weight of materials, shall be submitted to the Town prior to the Town’s demolition inspection. 13.STORY POLES: The story poles on the project site shall be removed within 30 days of approval of the Architecture & Site application. 14.TOWN INDEMNITY: Applicants are notified that Town Code Section 1.10.115 requires that any applicant who receives a permit or entitlement from the Town shall defend, indemnify, and hold harmless the Town and its officials in any action brought by a third party to overturn, set aside, or void the permit or entitlement. This requirement is a condition of approval of all such permits and entitlements whether or not expressly set forth in the approval, and may be secured to the satisfaction of the Town Attorney. 15.COMPLIANCE MEMORANDUM: A memorandum shall be prepared and submitted with the building plans detailing how the Conditions of Approval will be addressed. Building Division 16.PERMITS REQUIRED: A Demolition Permit is required for the demolition of the existing single-family residence. A separate Building Permit is required for the construction of the new single-family residence and attached garage. 17.APPLICABLE CODES: The current codes, as amended and adopted by the Town of Los Gatos as of January 1, 2020, are the 2019 California Building Standards Code, California Code of Regulations Title 24, Parts 1-12, including locally adopted Energy Reach Codes. 18.CONDITIONS OF APPROVAL: The Conditions of Approval must be blue lined in full on the cover sheet of the construction plans. A Compliance Memorandum shall be prepared and submitted with the building permit application detailing how the Conditions of Approval will be addressed. 19.SIZE OF PLANS: Submit four sets of construction plans, minimum size 24” x 36”, maximum size 30” x 42”. 20.REQUIREMENTS FOR COMPLETE DEMOLITION OF STRUCTURE: Obtain a Building Department Demolition Application and a Bay Area Air Quality Management District Application from the Building Department Service Counter. Once the demolition form has been completed, all signatures obtained, and written verification from PG&E that all utilities have been disconnected, return the completed form to the Building Department Service Counter with the Air District’s J# Certificate, PG&E verification, and three (3) sets of site plans showing all existing structures, existing utility service lines such as water, sewer, and PG&E. No demolition work shall be done without first obtaining a permit from the Town. 21. SOILS REPORT: A Soils Report, prepared to the satisfaction of the Building Official, containing foundation and retaining wall design recommendations, shall be submitted with the Building Permit Application. This report shall be prepared by a licensed Civil Engineer specializing in soils mechanics. 22. SHORING: Shoring plans and calculations will be required for all excavations which exceed five (5) feet in depth or which remove lateral support from any existing building, adjacent property, or the public right-of-way. Shoring plans and calculations shall be prepared by a California licensed engineer and shall confirm to the Cal/OSHA regulations. 23. FOUNDATION INSPECTIONS: A pad certificate prepared by a licensed civil engineer or land surveyor shall be submitted to the project Building Inspector at foundation inspection. This certificate shall certify compliance with the recommendations as specified in the Soils Report, and that the building pad elevations and on-site retaining wall locations and elevations have been prepared according to the approved plans. Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered Civil Engineer for the following items: a. Building pad elevation b. Finish floor elevation c. Foundation corner locations d. Retaining wall(s) locations and elevations 24. TITLE 24 ENERGY COMPLIANCE: All required California Title 24 Energy Compliance Forms must be blue-lined (sticky-backed), i.e. directly printed, onto a plan sheet. 25. TOWN RESIDENTIAL ACCESSIBILITY STANDARDS: New residential units shall be designed with adaptability features for single-family residences per Town Resolution 1994-61: a. Wood backing (2” x 8” minimum) shall be provided in all bathroom walls, at water closets, showers, and bathtubs, located 34 inches from the floor to the center of the backing, suitable for the installation of grab bars if needed in the future. b. All passage doors shall be at least 32-inch doors on the accessible floor level. c. The primary entrance door shall be a 36-inch-wide door including a 5’x 5’ level landing, no more than 1 inch out of plane with the immediate interior floor level and with an 18- inch clearance at interior strike edge. d. A door buzzer, bell or chime shall be hard wired at primary entrance. 26. BACKWATER VALVE: The scope of this project may require the installation of a sanitary sewer backwater valve per Town Ordinance 6.50.025. Please provide information on the plans if a backwater valve is required and the location of the installation. The Town of Los Gatos Ordinance and West Valley Sanitation District (WVSD) requires backwater valves on drainage piping serving fixtures that have flood level rims less than 12 inches above the elevation of the next upstream manhole. 27. HAZARDOUS FIRE ZONE: All projects in the Town of Los Gatos require Class A roof assemblies. 28. WILDLAND-URBAN INTERFACE: This project is located in a Wildland-Urban Interface High Fire Area and must comply with Section R337 of the 2016 California Residential Code, Public Resources Code 4291 and California Government Code Section 51182. 29. PROVIDE DEFENSIBLE SPACE/FIRE BREAK LANDSCAPING PLAN: Prepared by a California licensed Landscape Architect in conformance with California Public Resources Code 4291 and California Government Code Section 51182. 30. PRIOR TO FINAL INSPECTION: Provide a letter from a California licensed Landscape Architect certifying the landscaping and vegetation clearance requirements have been completed per the California Public Resources Code 4291 and Government Code Section 51182. 31. SPECIAL INSPECTIONS: When a special inspection is required by CBC Section 1704, the Architect or Engineer of Record shall prepare an inspection program that shall be submitted to the Building Official for approval prior to issuance of the Building Permit. The Town Special Inspection form must be completely filled-out and signed by all requested parties prior to permit issuance. Special Inspection forms are available from the Building Division Service Counter or online at www.losgatosca.gov/building. 32. BLUEPRINT FOR A CLEAN BAY SHEET: The Town standard Santa Clara Valley Nonpoint Source Pollution Control Program Sheet (page size same as submitted drawings) shall be part of the plan submittal as the second page. The specification sheet is available at the Building Division Service Counter for a fee of $2 or at ARC Blueprint for a fee or online at www.losgatosca.gov/building. 33. APPROVALS REQUIRED: The project requires the following departments and agencies approval before issuing a building permit: a. Community Development – Planning Division: (408) 354-6874 b. Engineering/Parks & Public Works Department: (408) 399-5771 c. Santa Clara County Fire Department: (408) 378-4010 d. West Valley Sanitation District: (408) 378-2407 e. Local School District: The Town will forward the paperwork to the appropriate school district(s) for processing. A copy of the paid receipt is required prior to permit issuance. TO THE SATISFACTION OF THE DIRECTOR OF PARKS & PUBLIC WORKS: Engineering Division 34. GENERAL: All public improvements shall be made according to the latest adopted Town Standard Plans, Standard Specifications and Engineering Design Standards. All work shall conform to the applicable Town ordinances. The adjacent public right-of-way shall be kept clear of all job-related mud, silt, concrete, dirt and other construction debris at the end of the day. Dirt and debris shall not be washed into storm drainage facilities. The storing of goods and materials on the sidewalk and/or the street will not be allowed unless an encroachment permit is issued by the Engineering Division of the Parks and Public Works Department. The Owner and/or Applicant’s representative in charge shall be at the job site during all working hours. Failure to maintain the public right-of-way according to this condition may result in the issuance of correction notices, citations, or stop work orders and the Town performing the required maintenance at the Owner and/or Applicant's expense. 35. APPROVAL: This application shall be completed in accordance with all the conditions of approval listed below and in substantial compliance with the latest reviewed and approved development plans. Any changes or modifications to the approved plans or conditions of approvals shall be approved by the Town Engineer. 36. CONSTRUCTION PLAN REQUIREMENTS: Construction drawings shall comply with Section 1 (Construction Plan Requirements) of the Town’s Engineering Design Standards, which are available for download from the Town’s website. 37. ENCROACHMENT PERMIT: All work in the public right-of-way will require a Construction Encroachment Permit. All work over $5,000 will require construction security. It is the responsibility of the Owner and/or Applicant to obtain any necessary encroachment permits from affected agencies and private parties, including but not limited to, Pacific Gas and Electric (PG&E), AT&T, Comcast, Santa Clara Valley Water District, California Department of Transportation (Caltrans). Copies of any approvals or permits must be submitted to the Town Engineering Division of the Parks and Public Works Department prior to releasing any permit. 38. PRIVATE IMPROVEMENTS IN THE PUBLIC RIGHT-OF-WAY (INDEMNITY AGREEMENT): The property owner shall enter into an agreement with the Town for all existing and proposed private improvements within the Town’s right-of-way. The Owner shall be solely responsible for maintaining the improvements in a good and safe condition at all times and shall indemnify the Town of Los Gatos. The agreement must be completed and accepted by the Director of Parks and Public Works, and subsequently recorded by the Town Clerk at the Santa Clara County Office of the Clerk-Recorder, prior to the issuance of any grading or building permits. Please note that this process may take approximately six to eight (6-8) weeks. 39. PUBLIC WORKS INSPECTIONS: The Owner and/or Applicant or their representative shall notify the Engineering Inspector at least twenty-four (24) hours before starting any work pertaining to on-site drainage facilities, grading or paving, and all work in the Town's right- of-way. Failure to do so will result in penalties and rejection of any work that occurred without inspection. 40. RESTORATION OF PUBLIC IMPROVEMENTS: The Owner and/or Applicant or their representative shall repair or replace all existing improvements not designated for removal that are damaged or removed because of the Owner and/or Applicant or their representative's operations. Improvements such as, but not limited to: curbs, gutters, sidewalks, driveways, signs, pavements, raised pavement markers, thermoplastic pavement markings, etc., shall be repaired and replaced to a condition equal to or better than the original condition. Any new concrete shall be free of stamps, logos, names, graffiti, etc. Any concrete identified that is displaying a stamp or equal shall be removed and replaced at the Contractor’s sole expense and no additional compensation shall be allowed therefore. Existing improvement to be repaired or replaced shall be at the direction of the Engineering Construction Inspector and shall comply with all Title 24 Disabled Access provisions. The restoration of all improvements identified by the Engineering Construction Inspector shall be completed before the issuance of a certificate of occupancy. Owner and/or Applicant or their representative shall request a walk-through with the Engineering Construction Inspector before the start of construction to verify existing conditions. 41. SITE SUPERVISION: The General Contractor shall provide qualified supervision on the job site at all times during construction. 42. DESIGN CHANGES: Any proposed changes to the approved plans shall be subject to the approval of the Town prior to the commencement of any and all altered work. The Owner and/or Applicant’s project engineer shall notify, in writing, the Town Engineer at least seventy-two (72) hours in advance of all the proposed changes. Any approved changes shall be incorporated into the final “as-built” plans. 43. PLANS AND STUDIES: All required plans and studies shall be prepared by a Registered Professional Engineer in the State of California and submitted to the Town Engineer for review and approval. Additionally, any post-project traffic or parking counts, or other studies imposed by the Planning Commission or Town Council shall be funded by the Owner and/or Applicant. 44. GRADING PERMIT DETERMINATION DURING CONSTRUCTION DRAWINGS: In the event that, during the production of construction drawings and/or during construction of the plans approved with this application by the respective deciding body, it is determined that a grading permit would be required as described in Chapter 12, Article II (Grading Permit) of the Town Code of the Town of Los Gatos, an Architecture and Site Application would need to be submitted by the Owner and/or Applicant for review and approval by the Development Review Committee prior to applying for a grading permit. 45. DRIVEWAY: The driveway conform to existing pavement on Robin Way shall be constructed in a manner such that the existing drainage patterns will not be obstructed. 46. DRAINAGE IMPROVEMENT: Prior to the issuance of any grading/improvement permits, whichever comes first, the Owner and/or Applicant shall: a) design provisions for surface drainage; and b) design all necessary storm drain facilities extending to a satisfactory point of disposal for the proper control and disposal of storm runoff; and c) provide a recorded copy of any required easements to the Town. 47. SURVEYING CONTROLS: Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered civil engineer qualified to practice land surveying, for the following items: a. Retaining wall: top of wall elevations and locations. b. Toe and top of cut and fill slopes. 48. PRECONSTRUCTION MEETING: Prior to site work of any grading or building permits or the commencement of any site work, the general contractor shall: a. Along with the Owner and/or Applicant, attend a pre-construction meeting with the Town Engineer to discuss the project conditions of approval, working hours, site maintenance and other construction matters; b. Acknowledge in writing that they have read and understand the project conditions of approval and will make certain that all project sub-contractors have read and understand them as well prior to commencing any work, and that a copy of the project conditions of approval will be posted on-site at all times during construction. 49. RETAINING WALLS: A building permit, issued by the Building Department, located at 110 E. Main Street, may be required for site retaining walls. Walls are not reviewed or approved by the Engineering Division of Parks and Public Works during the grading permit plan review process. IMPROVEMENT PLANS: 50. WATER METER: The existing water meter, currently located within the Robin Way right-of- way, shall be relocated within the property in question, directly behind the public right-of- way line. The Owner and/or Applicant shall repair and replace to existing Town standards any portion of concrete flatwork within said right-of-way that is damaged during this activity prior to issuance of a certificate of occupancy. 51. SANITARY SEWER CLEANOUT: Sanitary sewer cleanout, shall be located within one (1) foot of the property line per West Valley Sanitation District Standard Drawing 3, or at a location specified by the Town. The Owner and/or Applicant shall repair and replace to existing Town standards any portion of concrete flatwork within said right-of-way that is damaged during this activity prior to issuance of a certificate of occupancy. 52. PUBLIC IMPROVEMENTS: The following improvements shall be installed by the Owner and/or Applicant. Plans for those improvements shall be prepared by a California registered civil engineer, reviewed and approved by the Town, and guaranteed by contract, Faithful Performance Security and Labor & Materials Security before the issuance of any grading or building permits or the recordation of a map. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. a. Robin Way: 2” overlay from the centerline to the lip of valley gutter, or alternative pavement restoration measure as approved by the Town Engineer. 53. CERTIFICATE OF OCCUPANCY: The Engineering Division of the Parks and Public Works Department will not sign off on a Temporary Certificate of Occupancy or a Final Certificate of Occupancy until all required improvements within the Town’s right-of-way have been completed and approved by the Town. 54. UTILITIES: The Owner and/or Applicant shall install all new, relocated, or temporarily removed utility services, including telephone, electric power and all other communications lines underground, as required by Town Code Section 27.50.015(b). All new utility services shall be placed underground. Underground conduit shall be provided for cable television service. The Owner and/or Applicant is required to obtain approval of all proposed utility alignments from any and all utility service providers before a Certificate of Occupancy for any new building can be issued. The Town of Los Gatos does not approve or imply approval for final alignment or design of these facilities. 55. SIDEWALK/CURB IN-LIEU FEE: A curb and sidewalk in-lieu fee of $12,320 shall be paid prior to issuance of a grading or building permit. This fee is based on 88 linear feet of curb at $68.00 per linear foot and 396 square feet of 4.5-foot wide sidewalk at $16.00 per square foot in accordance with Town policy and the Town’s Comprehensive Fee Schedule. The final curb and sidewalk in-lieu fee for this project shall be calculated using the current fee schedule and rate schedule in effect at the time the fee is paid. 56. VALLEY GUTTER REPAIR: The Owner/Applicant shall repair and replace to existing Town standards any valley gutter damaged now or during construction of this project. All new and existing adjacent infrastructure must meet Town standards. New valley gutter shall be constructed per Town Standard Details. New concrete shall be free of stamps, logos, names, graffiti, etc. Any concrete identified that is displaying a stamp or equal shall be removed and replaced at the Contractor’s sole expense and no additional compensation shall be allowed therefore. The limits of valley gutter repair will be determined by the Engineering Construction Inspector during the construction phase of the project. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. 57. FENCES: Fences between all adjacent parcels will need to be located on the property lines/boundary lines. Any existing fences that encroach into the neighbor’s property will need to be removed and replaced to the correct location of the boundary lines before a Certificate of Occupancy for any new building can be issued. Waiver of this condition will require signed and notarized letters from all affected neighbors. 58. PERMIT ISSUANCE: Permits for each phase; reclamation, landscape, and grading, shall be issued simultaneously. 59. COVERED TRUCKS: All trucks transporting materials to and from the site shall be covered. 60. NPDES STORMWATER COMPLIANCE: In the event that, during the production of construction drawings for the plans approved with this application by the Town of Los Gatos, it is determined that the project will create and/or replace more than 2,500 square feet of impervious area, completion of the NPDES Stormwater Compliance Small Projects Worksheet and implementation of at least one of the six low impact development site design measures it specifies shall be completed and submitted to the Engineering Division before issuance of a building permit. TO THE SATISFACTION OF THE SANTA CLARA COUNTY FIRE DEPARTMENT: 61. FIRE SPRINKLERS REQUIRED: (As noted on Sheet A-1) An automatic residential fire sprinkler system shall be installed in one- and two-family dwellings as follows: In all new one- and two-family dwellings and in existing one- and two-family dwellings when additions are made that increase the building area to more than 3,600 square feet. Exception: One or more additions made to a building after January 1, 2011 that does not total more than 1,000 square feet of building area. An automatic sprinkler system shall be provided throughout all new basements regardless of size and throughout existing basements that are expanded by more than 50%. Note: The owner(s), occupant(s) and any contractor(s) or subcontractor(s) are responsible for consulting with the water purveyor of record in order to determine if any modification or upgrade of the existing water service is required. A State of California licensed (C-16) Fire Protection Contractor shall submit plans, calculations, a completed permit application and appropriate fees to this department for review and approval prior to beginning their work. CRC Sec. 313.2 as adopted and amended by LGTC. 62. WATER SUPPLY REQUIREMENTS: (As noted on Sheet A-1) Potable water supplies shall be protected from contamination caused by fire protection water supplies. It is the responsibility of the applicant and any contractors and subcontractors to contact the water purveyor supplying the site of such project, and to comply with the requirements of that purveyor. Such requirements shall be incorporated into the design of any water-based fire protection systems, and/or fire suppression water supply systems or storage containers that may be physically connected in any manner to an appliance capable of causing contamination of the potable water supply of the purveyor of record. Final approval of the system(s) under consideration will not be granted by this office until compliance with the requirements of the water purveyor of record are documented by that purveyor as having been met by the applicant(s). 2016 CFC Sec. 903.35 and Health and Safety Code 13114.7 63. ADDRESS IDENTIFICATION: (As noted on Sheet A-1) New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Where required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall be a minimum 4 inches (101.6 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address numbers shall be maintained. CFC Sec. 505.1 64. CONSTRUCTION SITE FIRE SAFETY: (As noted on Sheet A-1) All construction sites must comply with applicable provisions of the CFC Chapter 33 and our Standard Detail and Specification S1-7. Provide appropriate notations on subsequent plan submittals, as appropriate to the project. CFC Chp. 33. N:\DEV\PC REPORTS\2020\2020 - Staff Reports and Exhibits\07-22-20\Item 2 - 146 Robin Way\Exhibit 3 - Recommended Conditions of Approval.docx This Page Intentionally Left Blank 146 Robin Way PROJECT DATA EXISTING CONDITIONS PROPOSED PROJECT REQUIRED/ PERMITTED Zoning district R-1:10 same - Land use Single-family home same - General Plan Designation low density residential same - Lot size: ·Square feet/acres 13,122 same 10,000 sq. ft. min. Exterior materials: ·siding stucco Wood, stone veneer, stucco - ·trim wood none - ·windows vinyl metal - ·roofing Wood shingles metal - Building floor area (sq. ft.): ·first floor 2,466 3,737 - ·second floor - - - ·garage 542 508 - ·cellar - - - Setbacks (ft.): ·front >25”25”-9” 25 feet minimum ·rear >25’27’-9” 20 feet minimum ·side <10’ 10’ 10 feet minimum ·side street - - 15 feet minimum Maximum height (ft.) 14’-15’ 18’-1” 30 feet maximum Building coverage (%) 24.1% 36.8% 40% maximum Floor Area Ratio (%) ·house 2,466 3,737 3,738 sq. ft. maximum ·garage 542 508 1,013 sq. ft. maximum Parking 2 2 two spaces minimum Tree Removals - 1 canopy replacement Sewer or septic sewer same - EXHIBIT 4 This Page Intentionally Left Blank EXHIBIT 5 This Page Intentionally Left Blank EXHIBIT 6 This Page Intentionally Left Blank December 9, 2019 Mr.. Diego Mora Community Development Department Town of Los Gatos 110 E. Main Street Los Gatos, CA 95031 RE: 146 Robin Way Dear Diego: I reviewed the drawings, and evaluated the site context. My comments and recommendations are as follows: Neighborhood Context The site is located in a traditional neighborhood dominated by one-story Ranch Style homes. Photographs of the site and neighborhood are shown on the following page. EXHIBIT 7 146 Robin Way Design Review Comments December 9, 2019 Page 2 House immediately across Robin WayThe Site and existing house House immediately to the left Nearby house to the left House immediately to the right Nearby house to the right Nearby house across Robin Way Nearby house across Robin Way 146 Robin Way Design Review Comments December 9, 2019 Page 3 ISSUES AND CONCERNS The fundamental Ranch Style fits well with this neighborhood, but there are a number of conflicts with the Residential Design Guidelines: 1. Multiple low slope roofs are not consistent with the Residential Design Guidelines. 3.5.1 Unify roof pitches 3.3.2 Height and bulk at front and side setbacks • Avoid eave lines and roof ridge lines that are substantially taller than the adjacent houses. 3.3.1 Develop the house plans and elevations together • Work within the traditional forms of the architectural style selected. Unless the architectural style selected clearly supports substantial complexity, generally keep building massing and roof forms simple as is the norm for traditional architecture. 146 Robin Way Design Review Comments December 9, 2019 Page 4 2. Metal roofing is not consistent with the Residential Design Guidelines. 3.8.2 Select materials that are sensitive to the surrounding neighborhood 3. The garage door with metal and translucent glazing is out of character with this neighborhood, and is not consistent with Residential Design Guideline 3.4.1. 3.4.1 Limit the prominence of garages • Avoid designs that allow the garage to dominate the street facade. • Integrate the garage into the house forms in a manner that de-emphasizes the garage doors. 4. Metal windows are not consistent with Residential Design Guideline 3.7.3 3.7.3 Match window materials to the architectural style and to the surrounding neighborhood • Wood windows are common in Los Gatos. Wood is still the desired choice for styles that traditionally used wood. However, today there are some window materials, such as vinyl clad wood windows that are not notice- ably different from wood at a short distance. They may be used if their visual appearance matches wood. • Generally, avoid metal windows. They may be considered acceptable for a Modern Style house, but would be strongly discouraged for all other styles. Windows with some depth from the frame to the glass are desirable. Proposed garage door 146 Robin Way Design Review Comments December 9, 2019 Page 5 5. The low slope box forms at the rear of the house are very awkward. 6. Changing materials in the same plane is not consistent with Residential Design Guideline 3.8.4. 146 Robin Way Design Review Comments December 9, 2019 Page 6 RECOMMENDATIONS The following recommendation focus on simplifying the design to improve its compatibility with the immediate neighborhood. 1. Simplify the taller boxy elements on the front facade. 2. Limit the wood siding to accent locations (e.g., recessed entry, rear patio and right side pop out). 3. Select a less prominent garage door compatible with the Ranch Style of the home and the immediate neighborhood. 4. Select a roof material more similar to other homes in the immediate neighborhood. 5. Use wood or other non-metal windows with traditional jamb dimensions. 6. Use wood trim at all windows and doors. 7. Simplify the wood pop up and roof on the rear facade and right side elevation. 146 Robin Way Design Review Comments December 9, 2019 Page 7 8. Reorient front bedroom to hold it within the main building from. Diego, please let me know if you have any questions, or if there are other issues that I did not address. Sincerely, CANNON DESIGN GROUP Larry L. Cannon This Page Intentionally Left Blank TOWN OF LOS GATOS PARKS AND PUBLIC WORKS DEPARTMENT PHONE (408) 399-5770 FAX (408) 354-6824 SERVICE CENTER 41 MILES AVENUE LOS GATOS, CA 95030 A Tree Review of The Proposed Single-Family Residence 146 Robin Way Los Gatos, California 95030 Property Owner: Mehrdad and Leila Dehkordi Architect: Kohlsaat & Associates APN: 532-12-015 Zoning: R-1:10 Submitted to: Diego Mora Assistant Planner Community Development Department Town of Los Gatos 110 E. Main Street Los Gatos, California 95030 Submitted by: Robert Moulden Los Gatos Town Arborist ISA Certified Arborist: #WE-0532A January 16, 2020 EXHIBIT 8 TOWN OF LOS GATOS PARKS AND PUBLIC WORKS DEPARTMENT PHONE (408) 399-5770 FAX (408) 354-6824 SERVICE CENTER 41 MILES AVENUE LOS GATOS, CA 95030 Introduction I have been requested by the Los Gatos Community Development Department to review the potential impacts on 6 trees associated with the construction of a Single-Family residence at 146 Robin Way, Los Gatos. Trees on Site Tree #1 is a Coastal Redwood with a diameter of approximately 38”. This tree is showing decent health and shows nice vigor located on neighboring property. It is slated to remain. Tree #2 is a Apple tree with a diameter of approximately 12” inches with a canopy of 12’. This tree is showing good health. This tree is proposed for removal. Tree #3 is a Persimmon with a diameter of approximately 10”. This tree is showing good health. It is slated to remain. Trees #4 is an Apricot with a diameter of approximately 10” with a canopy of 10’.It is in moderate health. This tree is proposed for removal. Tree #5 is a Fir tree with a diameter of approximately 22” with a canopy of 15’. This tree is proposed for removal due to proximity to power lines that are located on rear property line. Tree #6 is a Apple tree with a diameter of approximately 7” with a canopy of 8’. Tree is in good health. It is slated for removal. Tree #5 requires replacement of 2 – 24” box trees for a total of 2 trees to be planted on site before completion of the project. Recommendation Tree #1 is proposed to remain. The applicant is proposing removal of existing driveway and replacing with pavers as per plan details. Tree protection in the form of fencing shall be up and in place as far from tree trunk as is possible before construction begins. Tree #3 is proposed to remain and shall be protected for the duration of this project. Standard protection measures are appropriate to protect the tree during construction per Section 29.10.1005 of the Town Code. Any excavation around the tree will be hand digging. Trees #5 is approved for removal as requested pending submittal of Tree removal permit through Town Engineering office. TOWN OF LOS GATOS PARKS AND PUBLIC WORKS DEPARTMENT PHONE (408) 399-5770 FAX (408) 354-6824 SERVICE CENTER 41 MILES AVENUE LOS GATOS, CA 95030 1. If new plant material is installed under the canopies it should be drought tolerant materials. 2. Any trenching for new irrigation should be designed outside of the canopies. 3. A thin layer of mulch shall be installed beneath the unpaved area of the canopies and maintained throughout the project. 4. The Contractor shall adhere to the Town Code relating to Protection of Trees during construction: Sec.29.10.1005. – Protection of trees during construction (a) Protective tree fencing shall specify the following: (1) Size and materials: A five (5) or six (6) foot high chain link fencing, mounted on two-inch diameter galvanized iron posts, shall be driven into the ground to a depth of at least two (2) feet at no more than 10-foot spacing. For paving area that will not be demolished and when stipulated in a tree preservation plan, posts may be supported by a concrete base. (2) Area type to be fenced. Type I: Enclosure with chain link fencing of either the entire drip line area or at the tree protection zone (TPZ), when specified by a certified or consulting arborist. Type II: Enclosure for street trees located in a planter strip: chain link fence around the entire planter strip to the outer branches. Type III: Protection for a tree located in a small planter cut-out only (such as downtown): orange plastic fencing shall be wrapped around the trunk from the ground to the first branch with 2-inch wooden boards bound securely on the outside. Caution shall be used to avoid damaging any bark or branches. (3) Duration of Type I, II, III fencing. Fencing shall be erected before demolition; grading or construction begins and remain in place until final landscaping is required. Contractor shall first obtain the approval of the project arborist on record prior to removing a tree protection fence. (4) Warning sign. Each tree fence shall have prominently displayed an 8.5 x 11-inch sign stating: "Warning—Tree Protection Zone-this fence shall not be removed and is subject to penalty according to Town Code 29.10.1025". (b) All persons shall comply with the following precautions: TOWN OF LOS GATOS PARKS AND PUBLIC WORKS DEPARTMENT PHONE (408) 399-5770 FAX (408) 354-6824 SERVICE CENTER 41 MILES AVENUE LOS GATOS, CA 95030 (1) Prior to the commencement of construction, install the fence at the drip line, or tree protection zone (TPZ) when specified in an approved arborist report, around any tree and/or vegetation to be retained which could be affected by the construction and prohibit any storage of construction materials or other materials or vehicles inside the fence. The drip line shall not be altered in any way so as to increase the encroachment of the construction. (2) Prohibit excavation, grading, drainage and levelling within the drip line of the tree unless approved by the director. (3) Prohibit disposal or depositing of oil, gasoline, chemicals or other harmful materials within the drip line of or in drainage channels, swales or areas that may lead to the drip line of a protected tree (4) Prohibit the attachment of wires, signs or ropes to any protected tree. (5) Design utility services and irrigation lines to be located outside of the drip line when feasible. (6) Retain the services of the certified or consulting arborist for periodic monitoring of the project site and the health of those trees to be preserved. The certified or consulting arborist shall be present whenever activities occur which poses a potential threat to the health of the trees to be preserved. (7) The director and project arborist shall be notified of any damage that occurs to a protected tree during construction so that proper treatment may be administered. EXHIBIT 9 This Page Intentionally Left Blank EXHIBIT 10 Liz & Bill Crites 100 Cardinal Lane Los Gatos, CA 95032 May 18, 2020 TO: Town of Los Gatos - Development Review Committee RE: May 19, 2020 DRC Meeting Subject: Public Comment re 146 Robin Way Architecture and Site Application S-19-043. APN 532-12-015 Dear Members of the Town of Los Gatos, Development Review Committee, We are writing to ask that you NOT approve the application, in its current form, for the residence at 146 Robin Way. Those of us who live on Stonybrook, Cardinal and Robin consider ourselves very fortunate to live together in such a picturesque, cohesive and cooperative neighborhood, and we hope to find an amicable solution to the home needed for a wonderful family. However, we must object to this application for the following reasons: 1.The proposed increase in square footage is too big for the lot. The current home is just under 2200 sq. ft. The plans are to increase the size to approximately 4800 sq. ft. This is more than doubling the size. The lot size is just around 1/3 of an acre. There are only 4 other homes in this neighborhood with 5 bedrooms (proposed in the plan). Two of them (105 Stonybrook and 126 Robin) have just over 1/2 acre lots, with only 4564 sq. ft and 3967 sq. ft respectively). The third 5 bedroom home, at 120 Cardinal Lane is on .36 of an acre, but has only 2500 sq.ft. The 4th, at 120 Stonybrook, on .28 acres, has a basement. Proportionally this proposal is far too oversized in look and feel for this neighborhood. 2.The height is simply too tall. The height of the proposed home would dwarf some of the other homes on the street and take away views of the hills and trees from several of the homes, as well. While the total height may be just within the limits, it does not fit with the overall feel of the neighborhood. 3.The style is not in line with the current Ranch style permeating the neighborhood. There have been at least a dozen remodels within the last couple of decades in our neighborhood but all of them have maintained an exterior style that still fits well, esthetically, with the long standing and original ranch style this neighborhood was built with. This proposed modern exterior simply doesn’t fit. We hope there is another solution for Leila and Mehrdad to meet the needs of their family, perhaps a basement that would not cause the home to be so oversized both in total square footage and height, and a slightly more traditional facade keeping in line with the look and feel of this much loved neighborhood. Finally, I would like to sit in on the Zoom meeting as an observer. Thank you for your time. Respectfully, Liz & Bill Crites Lora Lee and James Zaky 140 Robin Way Los Gatos, Ca. 95032 Dear Members of the Development Review Committee, At the first DRC Meeting on May 19th, my husband represented our concerns about the 146 Robin Way Architecture and Site Application. I am now compelled to speak up also as I want to ensure you each have full visibility as to what has transpired since we last met. As the next-door neighbor who will be directly impacted by this Proposal, we hope you take this vote seriously as for us it will forever impact our views, our sense of privacy and our neighborhood charm. During the 20 years we have lived in the Stonybrook Subdivision, we have seen a number of homes including ours be remodeled and updated. Since many of you may not be familiar with our Subdivision, my husband is sending you photos of the upgraded California ranch style homes in the immediate area that we would like you to share in today’s Zoom Room. You will each discover that every single home that has been upgraded did so with a visible commitment to the Design Elements that are outlined in the Town of Los Gatos 2020 Plan which states that, “New structures, remodels, and landscapes, and hardscapes shall be designed to harmonize and blend with the scale and rhythm of the neighborhood”. The Application that you are reviewing today does not meet this Requirement. When we were last together at the DRC, all of you unanimously agreed that you would neither deny nor approve this proposed Architecture and Site Application in order to see if the Architect could work with the homeowners who would be directly impacted to propose changes that would address the concerns escalated by the neighbors. We assumed that the Committee and more importantly the Architect and Applicant Homeowners would read our letters and listen to our concerns. Since that Forum, we learned that relative to the Homeowners this was not the case. When we met with the Architect at the Homeowner’s Property, he presented the proposed changes which included: 12” inch drop in elevation height, change in the color of the metal industrial roof which they have softened by adjusting the color from black to brown, and an extended roof line to cover the top edge of the stone portion of the façade only. Although it had not been made apparent to us, we learned that their Landscaping Plan which includes the removal of the two tall, very large and very mature trees which today provide the only sense of privacy we have in our backyard. We don’t want to wait another 10 years for new trees to mature so that we once again have privacy yet this has not been sufficiently addressed. My husband documented our concerns for the Committee and also sent Mehrdad and Leila a personal letter indicating how much we appreciate them as neighbors yet feel very concerned by the impact of their construction to our lives. My husband will no longer see the sky and trees from his office windows and our guest room. Instead, there is no longer a view but rather a metal industrial roof. We addressed concerns over the selected architecture, scale, and design. Unfortunately, we assumed that they would read our letter and would do something to specifically address our issues. In preparation for our conversation today, they met with the neighbors in groups to present their proposed adjustments. When the Architect closed by asking if they had now met our concerns we were shocked as the minor adjustments did not even scratch the surface. My husband looked directly at Leila and Mehrdad and asked, “Did either of you even read our personal letter from May 13th or the Documents and Photos I submitted to the DRC?” My husband would like you to show the photos that he has taken from our windows to show you the dramatic impact of your new metal roof and stucco hardscape relative to the views that we enjoy today. You are now completely blocking our views of any trees, sky or sunlight?” Leila just looked and my husband and responded to his question by shaking her head “No”. For neighbors who led us to believe how much they cared, it was amazing to discover that they proposed changes without even taking the time to understand nor address our concerns in a meaningful way. We find it very disappointing that they have not taken the time to demonstrate that they understand the concerns of the immediate neighbors in the Subdivision who will be directly impacted. They don’t have an appreciation for why we want to retain our views; our privacy, and uphold our property value. I strongly urge you to deny this Application and with that I will turn it over to the next Speaker. Thanks for your time. Liz & Bill Crites 100 Cardinal Lane Los Gatos, CA 95032 TO: Town of Los Gatos - Development Review Committee RE: June 9, 2020 DRC Meeting Subject: Public Comment re 146 Robin Way Architecture and Site Application S-19-043. APN 532-12-015 Dear Members of the Town of Los Gatos, Development Review Committee, We are writing to ask that you NOT approve the application, in its current form, for the residence at 146 Robin Way. This is our second letter stating our disapproval of the current plans. The first was submitted to the May 19th DRC meeting. Our main concern is that the facade of the home is simply too modern to blend in with the rest of the homes in our Stonybrook neighborhood. While we appreciate that the homeowners set up driveway meetings with groups of opposing neighbors and the architect, to review the changes they had made since the May 19th mtg, and answer any questions, we feel the style changes are negligible. In fact, after looking at the original drawings and the new drawings for some time, I had to ask the architect to point out the changes as they were not at all clear to see. We hear the architect when he says this is a Transitional Style and not a Modern Style home design, however, in comparison to the other homes is this neighborhood we argue it is quite a bit more modern that the rest. We feel very strongly that the homes in this charming and tight knit neighborhood should remain in the style that is currently existing in order it to maintain its much sought after appeal. Approving this modern home would most certainly set a precedent for the approval of even more modern style homes to come with the next request. The homeowners delivered to us their May 19 letter to the DRC on June 6. It states only 5 neighbors, out of 32 homes have objected in writing. While that is true, there are at least 5-7 more who object to the modern style but have not put their objections into writing. In addition, 4 of the homes (3 direct neighbors of the applicant) are currently being rented and not owner occupied. I urge the DCR, who I understand are not residents of Los Gatos, to find more than the one neighbor sited in this letter, who feels the “houses are tired-looking”. There are approximately 12 fo the 32 homeowners in the Stonybrook neighborhood who have owned and lived here for at least 25 years, some nearing 40 years. Additional owners who have bought into the area within the last 20 years, and as recent as the last 4 years, have all remodeled and kept well within a ranch style that fits seemlessly into the esthetic of the existing homes. We simply do not believe this home, as currently designed, will do the same. I will be sitting in on and would like to speak at the Zoom meeting on June 9, at 10am. Respectfully submitted, Liz & Bill Crites This Page Intentionally Left Blank 110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874 www.losgatosca.gov TOWN OF LOS GATOS DEVELOPMENT REVIEW COMMITTEE REPORT MINUTES OF THE DEVELOPMENT REVIEW COMMITTEE MEETING MAY 19, 2020 The Development Review Committee of the Town of Los Gatos conducted a Regular Teleconference Meeting on May 19, 2020, at 10:00 a.m. ROLL CALL Present Electronically: Sally Zarnowitz, CDD Planning; Robert Gray, CDD Building; Mike Weisz and Corvell Sparks, PPW Engineering; Tracy Staiger and Katherine Baker, SCCFD MEETING CALLED TO ORDER AT 10:00 AM PLEDGE OF ALLEGIANCE Committee members recited the Pledge of Allegiance. Attendees invited to participate. VERBAL COMMUNICATIONS -None PUBLIC HEARINGS 1.49-51 N. Santa Cruz Avenue Conditional Use Permit Modification Application U-20-004 Requesting approval of modifications to an existing Conditional Use Permit including expanded hours of operation for a restaurant with alcohol service (Gardino Fresco) on property zoned C-2. APN 510-44-030. PROPERTY OWNER: Joann M. White Trustee & ET AL APPLICANT: Pete Jillo PROJECT PLANNER: Sean Mullin Sean Mullin, Associate Planner, presented the staff report. Opened Public Comment. Pete Jillo -He is the owner speaking on behalf of the request. EXHIBIT 11 PAGE 2 OF 4 DEVELOPMENT REVIEW COMMITTEE MINUTES OF MAY 19, 2020 Maria Ristow -She is interested in the recommended Conditions of Approval for the request. Closed Public Comment. Committee members discussed the matter. MOTION: Motion by Robert Gray to approve. Seconded by Tracy Staiger. VOTE: Motion passed unanimously. 2.78 West Main Street Conditional Use Permit Application U-20-005 Requesting approval for a new restaurant with beer and wine service (The Tasting House) on property zoned C-2:LHP. APN 529-02-007. PROPERTY OWNER: Rita I. Minnis. APPLICANT: Michael A. Thornberry PROJECT PLANNER: Diego Mora Diego Mora, Assistant Planner, presented the staff report. Opened Public Comment. Bess Wiersema -She is the architect speaking on behalf of the request. Closed Public Comment. Committee members discussed the matter. MOTION: Motion by Mike Weisz to approve. Seconded by Robert Gray. VOTE: Motion passed unanimously. 3.146 Robin Way Architecture and Site Application S-19-043 Requesting approval for demolition of an existing single-family residence and construction of a new single-family residence on property zoned R-1:10. APN 532-12-015. PROPERTY OWNER: Mehrdad & Leila Dehkordi APPLICANT: Gary Kohlsaat PROJECT PLANNER: Diego Mora PAGE 3 OF 4 DEVELOPMENT REVIEW COMMITTEE MINUTES OF MAY 19, 2020 Diego Mora, Assistant Planner, presented the staff report. Opened Public Comment. Gary Kohlsaat - He is the architect speaking on behalf of the request. This is a single-story home in a single- story neighborhood in a transitional style bridging the traditional forms with modern materials. The 4:12 hipped roof is compatible with the neighborhood and the metal material is high quality and environmentally green. The height is only slightly higher than that of the existing home and is screened with evergreens. Jim Zaky - He is the neighbor at 140 Robin Way. He has reviewed the drawings and is requesting the proposed home be rejected, as it does not conform to the Design Element of the General Plan, and it will be higher and closer to his house that the current home. Mark Willey - He is a neighbor and submitted written comments before the meeting. He is requesting the home not be approved, as he is concerned it is not in harmony with the neighborhood in terms of scale and size. He also notes that a cellar has not been proposed to reduce its size above ground. Robert Buxton - He is a neighbor and submitted written comments before the meeting. He is against the project. This is a special neighborhood which deserves respect, and previous remodels have been respectful. Leila Dehkordi - She is the owner speaking on behalf of the request. Her family has lived in the house for years, but they have outgrown in and it is in poor condition, making repairs more difficult than construction of a new house. Closed Public Comment. Committee members discussed the matter. MOTION: Motion by Sally Zarnowitz to continue to a date certain of June 2, 2020 to allow the applicants to address neighbor concerns. Seconded by Robert Gray. VOTE: Motion passed unanimously. PAGE 4 OF 4 DEVELOPMENT REVIEW COMMITTEE MINUTES OF MAY 19, 2020 OTHER BUSINESS - None ADJOURNMENT The meeting adjourned by 11:00 a.m. Prepared by: _____________________________________ /s/ Sally Zarnowitz, Planning Manager 110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874 www.losgatosca.gov TOWN OF LOS GATOS DEVELOPMENT REVIEW COMMITTEE REPORT MINUTES OF THE DEVELOPMENT REVIEW COMMITTEE MEETING JUNE 2, 2020 The Development Review Committee of the Town of Los Gatos conducted a Regular Teleconference Meeting on June 2, 2020, at 10:00 a.m. ROLL CALL Present Electronically: Joel Paulson, CDD; Sally Zarnowitz, CDD Planning; Robert Gray, CDD Building; Mike Weisz and Corvell Sparks, PPW Engineering; Tracy Staiger and Katherine Baker, SCCFD MEETING CALLED TO ORDER AT 10:00 AM PLEDGE OF ALLEGIANCE Committee members recited the Pledge of Allegiance. Attendees invited to participate. VERBAL COMMUNICATIONS -None PUBLIC HEARINGS 1.35 University Avenue, Building E, Suite 35 Conditional Use Permit Application U-20-002 Requesting approval for group classes (Core Power Yoga) on property zoned C- 2:LHP:PD. APN 529-02-044. PROPERTY OWNER: SRI Old Town LLC APPLICANT: Amber DeMaglio PROJECT PLANNER: Sean Mullin Sean Mullin, Associate Planner, presented the staff report. Opened Public Comment. Amber DeMaglio -She is the applicant speaking on behalf of the request. Closed Public Comment. EXHIBIT 12 PAGE 2 OF 2 DEVELOPMENT REVIEW COMMITTEE MINUTES OF JUNE 2, 2020 N:\DEV\DRC\MINUTES\Min 2020\06-02-20 Minutes - FINAL.docx Committee members discussed the matter. MOTION: Motion by Robert Gray to approve. Seconded by Mike Weisz. VOTE: Motion passed unanimously. 2.146 Robin Way Architecture and Site Application S-19-043 Requesting approval for demolition of an existing single-family residence and construction of a new single-family residence on property zoned R-1:10. APN 532-12-015. PROPERTY OWNER: Mehrdad & Leila Dehkordi APPLICANT: Gary Kohlsaat PROJECT PLANNER: Diego Mora Continued from May 19, 2020 This item is being continued to June 9, 2020. MOTION: Motion by Robert Gray to continue item to June 9, 2020 DRC meeting. Seconded by Katherine Baker. VOTE: Motion passed unanimously. OTHER BUSINESS -None ADJOURNMENT The meeting adjourned by 10:13 a.m. Prepared by: _____________________________________ /s/ Sally Zarnowitz, Planning Manager 110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874 www.losgatosca.gov TOWN OF LOS GATOS DEVELOPMENT REVIEW COMMITTEE REPORT MINUTES OF THE DEVELOPMENT REVIEW COMMITTEE MEETING JUNE 9, 2020 The Development Review Committee of the Town of Los Gatos conducted a Regular Teleconference Meeting on June 9, 2020, at 10:00 a.m. ROLL CALL Present electronically: Joel Paulson, CDD; Sally Zarnowitz, CDD Planning; Robert Gray, CDD Building; Mike Weisz and Corvell Sparks, PPW Engineering; Katherine Baker, SCCFD MEETING CALLED TO ORDER AT 10:00 AM VERBAL COMMUNICATIONS -None PUBLIC HEARINGS 1.105 N. Santa Cruz Avenue Conditional Use Permit Application U-19-017 Requesting approval of a modification to an existing Conditional Use Permit for group classes located within an existing formula retail business (Athleta) on property zoned C-2. APN 510-17-067. PROPERTY OWNER: Stahl Edward C Trustee APPLICANT: Edward C. Stahl PROJECT PLANNER: Diego Mora Diego Mora, Assistant Planner, presented the staff report. Opened Public Comment. A project representative spoke on behalf of the request. Closed Public Comment. Committee members discussed the matter. EXHIBIT 13 PAGE 2 OF 4 DEVELOPMENT REVIEW COMMITTEE MINUTES OF JUNE 9, 2020 N:\DEV\DRC\MINUTES\Min 2020\06-9-20 Minutes - FINAL.docx MOTION: Motion by R. Gray to approve with required findings and recommended conditions of approval. Seconded by K. Baker. VOTE: Motion passed unanimously. 2.146 Robin Way Architecture and Site Application S-19-043 Requesting approval for demolition of an existing single-family residence and construction of a new single-family residence on property zoned R-1:10. APN 532-12-015. PROPERTY OWNER: Mehrdad & Leila Dehkordi APPLICANT: Gary Kohlsaat PROJECT PLANNER: Diego Mora Continued from June 2, 2020 Diego Mora, Assistant Planner, presented the staff report. Opened Public Comment. Gary Kohlsaat He is the architect speaking on behalf of the request. They reached out to the neighbors and met in keeping with the COVID-19 order. They provided more drawings to illustrate the neighborhood context. They revised the design of this single-story building by lowering the height by 14 inches, changing the color palette to be warmer, and replacing the flat parapet over the front bay with a hip roof to simplify the roof lines. Gordon Yamate He is a neighbor living on Robin Way. He sent an earlier message of enthusiastic support for the fresh and stunning design. He understands there were concerns and believes the project has addressed the concerns by modifying the design and the size. Regarding concerns about the ranch style, in fact recent remodels have replaced ranch styles with fresh designs. He would be very distressed if there were other concerns about changes to the neighborhood that are at the heart of the current problems facing our Nation. Finally, he is upset that anyone would imply the outreach was less than honest and complete. James Zaky He and Mrs. Zaky live adjacent to the project to the south at 140 Robin Way. He did attend a neighborhood meeting, however, unfortunately the changes did not resolve his concerns regarding his view to the north. He believes the scale conflicts with the Design Element of the General Plan. Currently the view from their yard is covered by an apple tree and PAGE 3 OF 4 DEVELOPMENT REVIEW COMMITTEE MINUTES OF JUNE 9, 2020 N:\DEV\DRC\MINUTES\Min 2020\06-9-20 Minutes - FINAL.docx landscaping that they understand will be removed and they are concerned about privacy in that regard. In terms of due process, he is confused by a statement made by the architect at the neighborhood meeting and wants to understand that the decision today is not before the Planning Commission. Liz Crites She is a neighbor on Cardinal Lane. She loves this immediate neighborhood, its look, feel, and people. She fully understands the need to increase a house to meet the needs of a family. The changes to the façade that she was shown were not readily apparent to her. This neighborhood is desirable because of the character of the traditional ranch style homes, and she doesn’t want that character eroded by this precedent. She feels that in part the job of the architect is to understand the desires of the neighbors. Lora Lee Zaky She and Mr. Zaky live adjacent to the project to the south at 140 Robin Way. She feels strongly because they are the immediate neighbors whose personal privacy will be impacted. They were upset that Mr. Dehkordi stated he had not read their letter when they met. She has photos of seven homes in the neighborhood that have been updated in the country ranch style. Directly impacted neighbors are those that are upset by the proposed home. Robert Buxton He is a neighbor who has submitted correspondence outlining neighbor concerns, and the concerns have not been addressed. He is asking for a continuance; preferably to a meeting that would take place in the Council Chambers. The concerned neighbors have the upmost regard for the property owners. Some people did not receive their letters until yesterday, and there is ample reason for a continuance again. Mehrdad Dehkordi He is the owner speaking on behalf of the request. He is grateful to the neighbors who have supported the project. It has been a difficult time. They have tried to communicate with the neighborhood. He misunderstood the Zakys’ question at their meeting, but he did read their letter. They have modified the design. They have been responsive and willing to compromise. He is thankful for consideration of the project today. Sally Zarnowitz Could the applicants speak to the screening on the south property line – would they be willing to install an eight-foot fence if that is amenable to the Zakys? Gary Kohlsaat The apple tree is in poor condition. They are willing to install an eight-foot fence and increase landscape screening for privacy on the south side. PAGE 4 OF 4 DEVELOPMENT REVIEW COMMITTEE MINUTES OF JUNE 9, 2020 N:\DEV\DRC\MINUTES\Min 2020\06-9-20 Minutes - FINAL.docx Mr. Zaky He is amenable to an eight-foot side yard fence; however, he does not feel it will address his concerns. Closed Public Comment. Committee members discussed the matter. MOTION: Motion by R. Gray to approve with required findings and recommended conditions of approval, with an additional condition that the South side fence shall not be less than eight feet in height; and screening shall be added to the satisfaction of the Community Development Director. Seconded by K. Baker. VOTE: Motion passed unanimously. OTHER BUSINESS - None ADJOURNMENT The meeting adjourned 10:45 a.m. Prepared by: _____________________________________ /s/ Sally Zarnowitz, Planning Manager EXHIBIT 14 This Page Intentionally Left Blank EXHIBIT 15 This Page Intentionally Left Blank OF REVISIONS DATE: SCALE:51 UNIVERSITY AVE. "L" • LOS GATOS, CA. • 95030 • (408) 395-2555S H E E TA NEW RESIDENCE:THE DEHKORDI RESIDENCE146 ROBIN WAY LOS GATOS, CAAS SHOWN A-1 11/12/19 -1 COVER SHEET 01/03/20A. 01/21/20B. 02/10/20C. 05/28/20D. A-1 A-2 A-3 A-4 C-1 C-2 C-3 C-4 L-1 A-5 A-6 A-7 A-8 A-9 A-10 A-11 COVER SHEET NEIGHBORHOOD PLAN & STREETSCAPE STREETSCAPES SITE PLAN CIVIL COVER SHEET GRADING & DRAINAGE PLAN CROSS SECTIONS & MISC. DETAILS EROSION CONTROL/CONSTRUCTION MANAGEMENT PRELIMINARY LANDSCAPE PLAN PROPOSED FLOOR PLAN ROOF PLAN FRONT & LEFT ELEVATIONS REAR & RIGHT ELEVATIONS CROSS SECTIONS SHADOW STUDIES 3D VIEWS PROJECT DATA PROJECT ADDRESS: OWNER: APN#: ZONING: OCCUPANCY GROUP: CONSTRUCTION TYPE: GROSS & NET SITE AREA: AVERAGE SLOPE: RESIDENCE F.A.R. GARAGE F.A.R. 146 ROBIN WAY LOS GATOS, CA 95032 MEHRDAD & LEILA DEHKORDI 146 ROBIN WAY LOS GATOS, CA 95032 532-12-015 R-1:10 R-3; U V-B 13,112 SF < 5% = .35 - ( [13.112-5] X .20) 25 = .2851 = 3,738 SF = .10 - ([13.112-5] X .07) 25 = .0773 = 1,013 SF PROPOSED FLOOR AREAS: MAIN FLOOR TOTAL LIVING AREA GARAGE 3,737 SF 3,737 SF 508 SF EXISTING STRUCTURES TO BE REMOVED: LIVING AREA GARAGE 2,466 SF 542 SF SITE AREAS: RESIDENCE COVERED PORCH COVERED LOGGIA TOTAL BUILDING COVERAGE PATIOS & CONC. PATHS DRIVEWAY TOTAL IMPERVIOUS COVERAGE EXISTING RESIDENCE: 3,008 SF 150 SF 0 SF 3,158 SF 1,796 SF 963 SF 5,917 SF = 24.1% = 45.1% 4,245 SF 51 SF 526 SF 4,822 SF 463 SF 762 SF 6,047 SF = 36.8% = 46.1% EXISTINGPROPOSED PROJECT DIRECTORY ARCHITECT: KOHLSAAT & ASSOCIATES 51 UNIVERSITY AVENUE, SUITE L LOS GATOS, CA 95030 TEL: (408) 395-2555 SURVEYOR: CARNES & ASSOCIATES 9505 SUGAR BABE DRIVE GILROY, CA 95020 TEL: (408) 847-2013 CIVIL ENGINEER: NNR ENGINEERING 535 WEYEBRIDGE LANE SAN JOSE, CA 95123 TEL: (408) 348-7813 SOILS ENGINEER: WAYNE TING & ASSOC. 42329 OSGOOD ROAD, UNIT A FREMONT, CA 94539 TEL: (510) 623-7768 LANDSCAPE ARCHITECT: AMBIANCE GARDEN DESIGN 530 LAURENCE EXPWY. MAILBOX #377 SUNNYVALE, CA 94085 TEL: (408) 990-6999 • AUTOMATIC RESIDENTIAL FIRE SPRINKLERS SHALL BE INSTALLED. A STATE OF CALIFORNIA LICENSED (C-16) FIRE PROTECTION CONTRACTOR SHALL SUBMIT PLANS, CALCULATIONS, AND COMPLETES PERMIT APPLICATION AND APPROPRIATE FEES TO THE SANTA CLARA COUNTY FIRE DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO BEGINNING THEIR WORK. NOTE: THE OWNER(S), OCCUPANTS AND ANY CONTRACTOR(S) OR SUBCONTRACTOR(S) ARE RESPONSIBLE FOR CONSULTING WITH THE WATER PURVEYOR OF RECORD IN ORDER TO DETERMINE IF ANY MODIFICATION OR UPGRADE OF THE EXISTING WATER SERVICE IS REQUIRED. NOTE: COVERED PORCHES, PATIOS, BALCONIES, AND ATTIC SPACES MAY REQUIRE FIRE SPRINKLER COVERAGE. • POTABLE WATER SUPPLIES SHALL BE PROTECTED FROM CONTAMINATION CAUSED BY FIRE PROTECTION WATER SUPPLIES. IT IS THE RESPONSIBILITY OF THE APPLICANT AND ANY CONTRACTORS AND SUBCONTRACTORS TO CONTACT THE WATER PURVEYOR SUPPLYING THE SITE OF SUCH PROJECT, AND TO COMPLY WITH THE REQUIREMENTS OF THE PURVEYOR. SUCH REQUIREMENTS SHALL BE INCORPORATED INTO THE DESIGN OF ANY WATER-BASED FIRE PROTECTION SYSTEMS, AND/OR FIRE SUPPRESSION WATER SUPPLY SYSTEMS OR STORAGE CONTAINERS THAT MAY BE PHYSICALLY CONNECTED IN ANY MANNER TO AN APPLIANCE CAPABLE OF CAUSING CONTAMINATION OF THE POTABLE WATER SUPPLY OF THE PURVEYOR OF RECORD. FINAL APPROVAL OF THE SYSTEM(S) UNDER CONSTRUCTION WILL NOT BE GRANTED BY THE SANTA CLARA COUNTY FIRE DEPARTMENT UNTIL COMPLIANCE WITH THE REQUIREMENTS OF THE WATER PURVEYOR OF RECORD ARE DOCUMENTED BY THE PURVEYOR AS HAVING BEEN MET BY THE APPLICANT(S). • ADDRESS IDENTIFICATION: NEW AND EXISTING BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR RAOD FRONTING THE PROPERTY. THESE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, ADDRESS NUMBERS SHAL BE PROVIDED IN ADDITIONAL APPROVED LOCATIONS TO FACILITATE EMERGENCY RESPONSE, ADDRESS NUMBERS SHALL BE IN ARABIC NUMBERS OR ALPHABETIC LETTERS. NUMERS SHALL BE A MINIMUM OF 4" HIGH WITH A MIN. STROKE VIEWED FROM THE UBLIC WAY, A MONUMENT, POLE OR OTER SIGN OF MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. ADDRESS NUMBERS SHALL BE MAINTAINED. • CONSTRUCTION SITE IFRE SAFETY: ALL CONSTRUCTION SITES MUST COMPLY WITH APPLICABLE PROVISIONS OF THE CFC CHAPTER 33 AND OUR STANDARD DETAILS AND SPECIFICATION SI-7. PROVIDE APPROPRIATE NOTATIONS ON SUBSEQUENT PLAN SUBMITTALS, AS APPROPRIATE TO THE PROJECT. NOTES SHEET INDEX SCOPE OF WORK A NEW 3,737 SF SINGLE FAMILY RESIDENCE WHICH INCLUDES 5 BEDROOMS, 5½ BATHS, AND OFFICE AND A COVERED LOGGIA VICINITY MAP SITE The Dehkordi Residence EXHIBIT 16 OF REVISIONS DATE: SCALE:51 UNIVERSITY AVE. "L" • LOS GATOS, CA. • 95030 • (408) 395-2555S H E E TA NEW RESIDENCE:THE DEHKORDI RESIDENCE146 ROBIN WAY LOS GATOS, CAAS SHOWN A-2 11/12/19 -2 NEIGHBORH OOD PLAN & STREETSCAPE 01/03/20A. 01/21/20B. 02/10/20C. 05/28/20D. R=1050.00'L=87.99'Δ=004°48'05"N71°26'55"W 149.56'N76°14'59"W 131.34'S05°48'15"W 101.38' 146150156 106 112 118 140 136 130 126122 ★ ROBIN WAY SCALE: 1" = 30' NEIGHBORHOOD PLAN OF REVISIONS DATE: SCALE:51 UNIVERSITY AVE. "L" • LOS GATOS, CA. • 95030 • (408) 395-2555S H E E TA NEW RESIDENCE:THE DEHKORDI RESIDENCE146 ROBIN WAY LOS GATOS, CAAS SHOWN A-3 11/12/19 -3 STREETSCAPE S 01/03/20A. 01/21/20B. 02/10/20C. 05/28/20D. STREETSCAPE VIEW STREETSCAPE VIEW - no landscaping OF REVISIONS DATE: SCALE:51 UNIVERSITY AVE. "L" • LOS GATOS, CA. • 95030 • (408) 395-2555S H E E TA NEW RESIDENCE:THE DEHKORDI RESIDENCE146 ROBIN WAY LOS GATOS, CAAS SHOWN A-4 11/12/19 -4 SITE PLAN 01/03/20A. 01/21/20B. 02/10/20C. 05/28/20D.25'-0"FRONT SETBACK10'-0" 10'-0" SIDE SETBACK 20'-0"REAR SETBACK27'-9"10'-0" SIDE SETBACK 10'-13/4" 22'-0"25'-1"25'-9"15'-0" F.F.= 404.5' F.F.= 404.0' EXISTING DRIVEWAY TO BE REMOVED EXISTING PAVING TO BE REMOVED EXISTING PAVING TO BE REMOVED EXISTING RESIDENCE TO BE DEMOLISHED F.F. = 404.1' EXISTING SHED TO BE DEMOLISHED (E) 6' TALL WOOD FENCE TO REMAIN (E) 12"-24" TALL WOOD RETAINING WALL TO BE REPLACED (E) 12"-24" TALL RETAINING WALL TO REMAIN NEW 24"-30" TALL STONE FENCE NEW CONC. PAVING BLOCKS (E) DRIVEWAY TO BE REPLACED NEW GAS METER LOCATION (E) OVERHEAD ELEC/TEL/CABLE TO REPLACED UNDERGROUND (N) ELEC METER & PANEL CONTINUE 24" TALL BLOCK RETAINING WALL TREE TO BE REMOVED EXISTING PAVING TO BE REMOVED (E) 6' TALL WOOD FENCE TO REMAIN (E) 6' TALL WOOD FENCE TO REMAIN (N) WATER METER LOCATION CHAIN LINK FENCE TO BE REMOVED PROPOSED 6' TALL WOOD FENCE & GATE 404 403402 401403 403 402404403 402 405EX GARAGEFF= 403.1EX HOUSEFF= 404.1WVFHSSMH26" LIQUIDAMBER ROBIN WAY WM 14" LIQUID AMBER 30" REDWOOD 7" APPLE EXHOUSEEXHOUSEVGVGVGVG10" APRICOT 10" PERSIMMON 12" APPLE 22" FIR WOOD FENCE6' WOOD FENCE WOOD FENCE5' STORM DRAIN E A S E M E N T 25'25'WVGMEM5' CHAIN LINK FENC E LOT 19APN: 532-12-014LOT 17APN: 532-12-016R =10 5 0 .0 0 'L =8 7 .9 9 'Δ =0 0 4°4 8 '0 5 "N71°26'55"W 149.56'N76°14'59"W 131.34'S05°48'15"W 101. 3 8 ' PROPOSED RESIDENCE PROPOSED GARAGE COVERED PORCH COVERED LOGGIA BBQ PP PATIO DS DS DS DS DS DS DS DS DS DS DS WM #1 #2 #3 #4 #5 #6 150 ROBIN WAY 140 ROBIN WAY IMPERVIOUS AREAS LEGEND & TABLE PROPOSED RESIDENCE PROPOSED GARAGE EXISTING HOME TO BE DEMOLISHED PAVERS ON CONCRETE SLAB PAVERS ON SAND BED (DRIVEWAY) EXISTING PAVED PATHS AND PATIOS TO BE REMOVED 3,737 SF 508 SF PROPOSED DEMO 3,008 SF 825 SF 762 SF 2,909 SF 5,917 SFTOTAL IMPERVIOUS (DISTURBED) AREA 6,052 SF CONCRETE PAVING STONE PATH 215 SF SCALE: 1" = 10' SITE PLAN DATEREVISIONS N.T.S. 9-16-2019 NR SCALE: DATE: DRAWN BY: SHEET NO: JOB NO: 5 SHEETSOF GENERAL NOTES: UTILITY NOTES: ABBREVIATION NOTICE TO CONTRACTORS EARTH WORK NOTE: NOTE: STANDARD GRADING NOTES ´µ     STANDARD GRADING NOTES C-1 APPROXIMATE GRADING QUANTITIES (CU. YDS.) LOCATION CUT DEPTH FILL DEPTH TOTAL HOUSE/35 0.5' 0 0 SITE 5 5 0.5' TOTAL 40 5 35 0.8' DESCRIPTION LEGEND VICINITY MAP SITEKENNEDY RDROBIN WAYSTONYBROOK RDCARDINAL LN KENNEDY RDVIA SANTA MARIATOTAL AREA OF LAND DISTURBED =12,120± S.F. (0. 28 ACRE) 1 1 REVISIONS 9-16-2019 NR SCALE: DATE: DRAWN BY: SHEET NO: JOB NO: 5 SHEETSOF C-2 1" =10' GRADING AND DRAINAGE CONSTRUCTION NOTES: LEGEND: DRAINAGE NOTE DRAINAGE NOTE TREE FENCING NOTE NOTE DATE 1 1 390 400 410 390 400 410 BYREVISIONS 9-16-2019 NR SCALE: DATE: DRAWN BY: SHEET NO: JOB NO: 5 SHEETSOF C-3 AREA DRAIN DETAIL A A GRAVEL BASIN DETAIL NOTES: TREE PROTECTION DETAIL ROOF DOWNSPOUT/SPLASH BLOCK CATCH BASIN DETAIL AS SHOWN CONCRETE WALKWAY-TYPICAL SECTION DRIVEWAY PAVERS DETAIL NOTE: DRIVEWAY SHALL BE ABLE TO SUPPORT WEIGHT OF EMERGENCY TRUCKS, UP TO 20 TONS. PROJECT SOILS ENGINEER TO INSPECT THE CONSTRUCTION OF THE DRIVEWAY. REVISIONS 9-16-2019 NR SCALE: DATE: DRAWN BY: SHEET NO: JOB NO: 5 SHEETSOF C-4 1" =10' ENTRENCHMENT IN FLAT AREA STRAW WATTLES DETAIL TEMPORARY COVER ON STOCK PILE STABILIZED CONSTRUCTION ENTRANCE NOTES: STABILIZED CONSTRUCTION ENTRANCE BURLAP SACK DRAIN INLET (D.I.) SEDIMENT FILTER DETAIL NOTES: TEMPORARY CONCRETE WASHOUT FACILITY ( ABOVE GRADE) SEQUENCE OF CONSTRUCTION LEGEND STRAW WATTLES DATE 1 1 1 1 OF REVISIONS DATE: SCALE:51 UNIVERSITY AVE. "L" • LOS GATOS, CA. • 95030 • (408) 395-2555S H E E TA NEW RESIDENCE:THE DEHKORDI RESIDENCE146 ROBIN WAY LOS GATOS, CAAS SHOWN A-5 11/12/19 -10 PROPOSED FLOOR PLAN 01/03/20A. 01/21/20B. 02/10/20C. 05/28/20D.COOKTOPWDRDW 16'-0"16'-6"4'-8"20'-6"24'-6"11'-4"21'-4"16'-4"11'-9"12'-3"15'-6"8'-6"22'-0"13'-0"1'-0"1'-6"13'-0"2'-6"5'-10"14'-10"6'-6"12'-0"5'-9"11'-3"6'-0"10'-6"16'-1/2"6"7'-6"17'-6"77'-8"1'-0"30'-51/2"12'-0" 70'-0" 1'-6"1'-6"20'-0"20'-0"6"A A-9 A A-9 B A-9 B A-9 SKYLIGHTSKYLIGHT REQUIRED PARKING AREA ETHANOL FIREPLACE ETHANOL FIREPLACE LIVING ROOM (ceiling 11') DINING ROOM (ceiling 13'-6")FAMILY ROOM (ceiling 13'-6") KITCHEN (ceiling 10') OFFICE (ceiling 10') 2-CAR GARAGE MASTER BEDROOM (ceiling 10'-8"/ soffit 10') MASTER BATH (ceiling 9') BEDROOM 4 (ceiling 9'-8"/ soffit 9') GUEST SUITE (ceiling 9'-8"/ soffit 9') BATH 3 BATH 4 LAUNDRY POWDER GALLERY (ceiling 11') FOYER (ceiling 11') MUD ROOM (ceiling 9') COVERED LOGGIA COVERED ENTRY PANTRY MASTER CLOSET MASTER CLOSET (ceiling 9') BBQ AREA LINENBEDROOM 2 (ceiling 9'-8"/ soffit 9') BEDROOM 3 (ceiling 9'-8"/ soffit 9') BATH 2 HALL (ceiling 9') HALL (ceiling 9') CA-9 CA-9 SCALE: 1/4" = 1'-0" PROPOSED FLOOR PLAN OF REVISIONS DATE: SCALE:51 UNIVERSITY AVE. "L" • LOS GATOS, CA. • 95030 • (408) 395-2555S H E E TA NEW RESIDENCE:THE DEHKORDI RESIDENCE146 ROBIN WAY LOS GATOS, CAAS SHOWN A-6 11/12/19 -11 ROOF PLAN 01/03/20A. 01/21/20B. 02/10/20C. 05/28/20D. 1'-9" AA-9 AA-9 BA-9 BA-9 PVC MEMBRANE ROOFPVC MEMBRANE ROOF PVC MEMBRANE ROOFPVC MEMBRANE ROOF STANDING SEAM METAL ROOF SKYLIGHT SKYLIGHT SKYLIGHT SKYLIGHT DEC. CHIMENY CAP O/ SPARK ARRESTOR DEC. CHIMENY CAP O/ SPARK ARRESTOR SLOPED FACED METAL GUTTER TO MATCH ROOFING SLOPED FACED METAL GUTTER TO MATCH ROOFING RECTANGULAR METAL GUTTER RECTANGULAR METAL GUTTER PARAPET CURB W/ METAL FLASHING CAP PARAPET CURB W/ METAL FLASHING CAP PARAPET CURB W/ METAL FLASHING CAP PVC MEMBRANE ROOF PV SOLAR PANELSPV SOLAR PANELS PV SOLAR PANELS SLOPED FACED METAL GUTTER TO MATCH ROOFING STANDING SEAM METAL ROOF 4/124/124/12 4/12 4/124/124/124/124/12 4/124/12 4/12 4/12 4/12LOW SLOPE ROOF LOW SLOPE ROOF LOW SLOPEROOF4/12 4/124/12C A-9 C A-9 LOW SLOPE ROOF LOW SLOPE ROOF LOW SLOPE ROOF SCALE: 1/4" = 1'-0" ROOF PLAN OF REVISIONS DATE: SCALE:51 UNIVERSITY AVE. "L" • LOS GATOS, CA. • 95030 • (408) 395-2555S H E E TA NEW RESIDENCE:THE DEHKORDI RESIDENCE146 ROBIN WAY LOS GATOS, CAAS SHOWN A-7 11/12/19 -12 FRONT & LEFT ELEVATIONS 01/03/20A. 01/21/20B. 02/10/20C. 05/28/20D. 404.50' FINISHED FLOOR 404.50' FINISHED FLOOR 413.58' PLATE 413.58' PLATE 421.50' HIGHEST RIDGE 421.50' HIGHEST RIDGE 9'-1"11'-1"17'-6"STANDING SEAM METAL ROOF HORIZONTAL WOOD SIDING THIN STONE VENEER INTEGRAL COLOR, SMOOTH STUCCO METAL OVERHEAD GARAGE DOOR W/ OPAQUE LITESEXPOSED STEEL 'I' COLUMN SKYLIGHT ON CURB METAL FRAMED WINDOWS RECTANGULAR METAL GUTTER SLOPE FACED METAL GUTTER DEC. METAL CHIMNEY CAP O/ SPARK ARRESTORPARAPET CURB W/ METAL FLASHING CAP INTEGRAL COLOR, SMOOTH STUCCO OUTLINE OF ORIGINAL DESIGN PLATE 415.58' PLATE 415.58' 404.50' FINISHED FLOOR 404.50' FINISHED FLOOR 413.58' PLATE 413.58' PLATE 421.50' HIGHEST RIDGE 421.50' HIGHEST RIDGE 9'-1"18'-1"DEC. METAL CHIMNEY CAP O/ SPARK ARRESTOR INTEGRAL COLOR, SMOOTH STUCCO METAL FRAMED WINDOWS STANDING SEAM METAL ROOF THIN STONE VENEERSLOPE FACED METAL GUTTER SKYLIGHT ON CURB OUTLINE OF ORIGINAL DESIGN SCALE: 1/4" = 1'-0" FRONT ELEVATION SCALE: 1/4" = 1'-0" LEFT ELEVATION OF REVISIONS DATE: SCALE:51 UNIVERSITY AVE. "L" • LOS GATOS, CA. • 95030 • (408) 395-2555S H E E TA NEW RESIDENCE:THE DEHKORDI RESIDENCE146 ROBIN WAY LOS GATOS, CAAS SHOWN A-8 11/12/19 -13 REAR & RIGHT ELEVATIONS 01/03/20A. 01/21/20B. 02/10/20C. 05/28/20D. 404.50' FINISHED FLOOR 404.50' FINISHED FLOOR 413.58' PLATE 413.58' PLATE 421.50' HIGHEST RIDGE 421.50' HIGHEST RIDGE 9'-1"14'-1"18'-1"DEC. METAL CHIMNEY CAPDEC. METAL CHIMNEY CAP EXPOSED STEEL 'I' COLUMN HORIZONTAL WOOD SIDING INTEGRAL COLOR, SMOOTH STUCCO RECTANGULAR METAL GUTTER THIN STONE VENEER SLOPE FACED METAL GUTTER METAL FRAMED WINDOWS METAL FRAMED SLIDING DOORS STANDING SEAM METAL ROOFSKYLIGHT ON CURBPARAPET CURB W/ METAL FLASHING CAP INTEGRAL COLOR, SMOOTH STUCCO OUTLINE OF ORIGINAL DESIGN PLATE 418.58' PLATE 418.58' 404.50' FINISHED FLOOR 404.50' FINISHED FLOOR 413.58' PLATE 413.58' PLATE 421.50' HIGHEST RIDGE 421.50' HIGHEST RIDGE 9'-1"18'-1"14'-1"PARAPET CURB W/ METAL FLASHING CAPPARAPET CURB W/ METAL FLASHING CAP INTEGRAL COLOR, SMOOTH STUCCO RECTANGULAR METAL GUTTER STANDING SEAM METAL ROOF THIN STONE VENEER EXPOSED STEEL 'I' COLUMN HORIZONTAL WOOD SIDING METAL FRAMED WINDOWS SLOPE FACED METAL GUTTER DEC. METAL CHIMNEY CAP O/ SPARK ARRESTOR DEC. METAL CHIMNEY CAP OUTLINE OF ORIGINAL DESIGN PLATE 418.58' SCALE: 1/4" = 1'-0" REAR ELEVATION SCALE: 1/4" = 1'-0" RIGHT ELEVATION OF REVISIONS DATE: SCALE:51 UNIVERSITY AVE. "L" • LOS GATOS, CA. • 95030 • (408) 395-2555S H E E TA NEW RESIDENCE:THE DEHKORDI RESIDENCE146 ROBIN WAY LOS GATOS, CAAS SHOWN A-9 11/12/19 -14 CROSS SECTIONS 01/03/20A. 01/21/20B. 02/10/20C. 05/28/20D. 404.50' FINISHED FLOOR 404.50' FINISHED FLOOR 413.58' PLATE 413.58' PLATE 421.50' HIGHEST RIDGE 421.50' HIGHEST RIDGE 9'-1"10'-9"11'-1"OUTLINE OF ORIGINAL DESIGN MASTER BEDROOM CORRIDOR GUEST BATH GUEST BEDROOM18'-33/4"404.50' FINISHED FLOOR 404.50' FINISHED FLOOR 413.58' PLATE 413.58' PLATE 421.50' HIGHEST RIDGE 421.50' HIGHEST RIDGE 13'-7"9'-1"18'-1"11'-1"17'-6"OUTLINE OF ORIGINAL DESIGN FOYER GALLERY GREAT ROOM LOGGIACOVERED ENTRY PLATE 418.08' PLATE 415.58'11'-1"9'-1"OUTLINE OF ORIGINAL DESIGN EXISTING HOUSE TO BE DEMOLISHED BEDROOM 3 GALLERY KITCHENCORRIDOR 150 ROBIN WAY 140 ROBIN WAYPLATE 413.58' HIGHEST RIDGE 421.50' PLATE 413.58' HIGHEST RIDGE 421.50' FINISHED FLOOR 404.50' FINISHED FLOOR 404.50' SCALE: 1/8" = 1'-0" SECTION A-A SCALE: 1/8" = 1'-0" SECTION B-B SCALE: 1/8" = 1'-0" SECTION C-C OF REVISIONS DATE: SCALE:51 UNIVERSITY AVE. "L" • LOS GATOS, CA. • 95030 • (408) 395-2555S H E E TA NEW RESIDENCE:THE DEHKORDI RESIDENCE146 ROBIN WAY LOS GATOS, CAAS SHOWN A-10 11/12/19 -15 SHADOW STUDIES 01/03/20A. 01/21/20B. 02/10/20C. 05/28/20D. R=1050.00'L=87 .99'Δ =004°48'05"N71°26'55"W 149.56'N76°14'59"W 131.34'S05°48'15"W 101.38' ONE STORY HOME APPROX. 18'-20' TALL ONE STORY HOMEAPPROX. 14'-15' TALL R=1050.00'L=87 .99'Δ =004°48'05"N71°26'55"W 149.56'N76°14'59"W 131.34'S05°48'15"W 101.38' ONE STORY HOME APPROX. 18'-20' TALL ONE STORY HOMEAPPROX. 14'-15' TALL R=1050.00'L=87.99'Δ=004°4 8'05"N71°26'55"W 149.56'N76°14'59"W 131.34'S05°48'15"W 101.38' ONE STORY HOME APPROX. 18'-20' TALL ONE STORY HOMEAPPROX. 14'-15' TALL R=1050 .0 0 'L=87.99'Δ=0 0 4°48'05 "N71°26'55"W 149.56'N76°14'59"W 131.34'S05°48'15"W 101.38' ONE STORY HOME APPROX. 18'-20' TALL ONE STORY HOME APPROX. 14'-15' TALL R=1050.00'L=87 .99'Δ =004°48'05"N71°26'55"W 149.56'N76°14'59"W 131.34'S05°48'15"W 101.38' ONE STORY HOME APPROX. 18'-20' TALL ONE STORY HOME APPROX. 14'-15' TALL R=1050.00'L=87 .99'Δ =004°48'05"N71°26'55"W 149.56'N76°14'59"W 131.34'S05°48'15"W 101.38' ONE STORY HOME APPROX. 18'-20' TALL ONE STORY HOME APPROX. 14'-15' TALL December 21, 9am December 21, 12pm December 21, 3pm June 21, 3pmJune 21, 12pmJune 21, 9am SHADOW STUDIES SCALE: 1" = 20' OF REVISIONS DATE: SCALE:51 UNIVERSITY AVE. "L" • LOS GATOS, CA. • 95030 • (408) 395-2555S H E E TA NEW RESIDENCE:THE DEHKORDI RESIDENCE146 ROBIN WAY LOS GATOS, CAAS SHOWN A-11 11/12/19 -16 3D VIEWS 01/03/20A. 01/21/20B. 02/10/20C. 05/28/20D. STREET VIEW 1 REAR VIEW 2 STREET VIEW 2 REAR VIEW 1