Loading...
Item 4 - Exhibit 18 - Development Plans approved by Development Review Committee on 8-13-194 1/2 : 124 1/2 : 124 1/2 : 12 4 1/2 : 124 1/2 : 124 1/2 : 124 1/2 : 124 1/2 : 12cLcLWWWWWWWWWW WWW W W JT JT JT JT JT JT JT JT JTJTJTJTJTJTJT4 1/2 : 12 4 1/2 : 12 4 1/2 : 124 1/2 : 124 1/2 : 12 8'-0" SIDE SETBACK25'-0" FRONT SETBACK 15'-0" STREET SETBACK5'-0"20'-0" REAR SETBACK 5'-0" 5'-0"6'-5 1/2"61'-0"8'-0"1'-0"4 1/2 : 124 1/2 : 12 PROPERTY LINE 142.27'PROPERTY 66.37'PROPERTY 118.52'PROPERTY 39.98'5' 0" SWIMMING POOL SETBACK SHADY VIEW LN. (60' R.O.W.)SHANNON RD.(50' R.O.W.)(E) 26.4" OAK TREE TO REMAIN. (E) 45" REDWOOD PINE TO REMAIN. (E) 45" REDWOOD PINE TO REMAIN. (N)DRIVEWAY. (E) FIRE HYDRANT TO REMAIN. SSCO SDMH (E) JP (E) JP 4 1/2 : 124 1/2 : 12 APPROXIMATE LOCATION OF FUTURE POOL EQUIPMENT. EDGE PAVEMENT ROLLED CURBEDGE PAVEMENT EDGE P A V E M E N T ROLLED C U R B (E) 27" SMOKE TREE TO REMAIN.5' 0" SWIMMINGPOOL SETBACKFUTURE SWIMMING POOL (20'x15') Under a separate permit. 5' 0" SWIMMING POOL S E T B A C K (N) WATER METER. SSCO SSCO (N) CLEAN OUT LOCATION. 1 2 DN (E) CANOPY DRIPLINE, TYP. (N) CLEAN OUT LOCATION. (N) JOINT TRENCH TO CONNECT TO (N) UTILITIES. (N) ELEC. METER. 300 AMP. (N) GAS METER. PROJECT SIGN. SEE NOTE 'E' THIS PAGE.PROPERTY LINE 78.01'PROPERTY LINE 78.01' SECOND FLOOR BUILDING OUTLINE FIRST FLOOR BUILDING OUTLINE (E)SWIMMING POOL (E)EXISTING NON- CONFORMING POOL HOUSE9' HEIGHT.2 1/2 : 12APPROXIMATE LOCATION OF (E) 1-STORY HOME AT 16344 SHADY VIEW LN. APPROXIMATE LOCATION OF (E) 2-STORY HOME AT 16330 SHANNON RD. (N) MAIN HOUSESS SSSSSSSSSSSSSSSSSS(N) ATTACHED ADU (under a separate permit) SS SS SS SS (N) SEWER LINE.SDSDSDSDSDSDSDSDSDSDSDSDSDSD SDSDSDSSSSSSSSSSSSSSSSSSSSSSSSSSCO (E) HOUSE COVER SHEETSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW CSDESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BY DATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.CITY OF SARATOGA: CONSTRUCTION WORK HOURS: MONDAY - FRIDAY 7:30AM - 6:00PM SATURDAYS 9:00AM - 5:00PM SUNDAYS AND WEEKDAY HOLIDAYS PROHIBITED SITE MANAGEMENT: A. SITE SHALL BE MAINTAINED CLEAN AT ALL TIMES AND CONSTRUCTION DEBRIS HAULED OFF ON A REGULAR BASIS. B. "BEST MANAGEMENT PRACTICE" SHALL BE IN PLACE AND MAINTAINED DURING THIS PROJECT FOR PROTECTION OF ANY POLLUTANTS ENTERING THE EXISTING STORMWATER SYSTEM. COVERSHEET NOTES FOR SARATOGA RESPONSES TO PLAN CHECK COMMENTS LL103/26/2019Fill out "Tools>Project Information> Client Information" topopulate client information on cover sheet and title block. PROJECT DATA ZONING R1-8-PREZONE OCCUPANCY TYPE R3/U BUILDING TYPE VB APN 532-03-034 LOT AREA 8,610 SF (E) RESIDENCE TO BE REMOVED 1,056 SF FLOOR AREA: (N) 1st FLOOR 1,425.08 SF (N) 2ND FLOOR 1,273.67 SF TOTAL 2,698.75 SF (N) FAR 31 % > MAX. 32 % (N) ATTACHED GARAGE:422.81 SF FAR 5 % < MAX. 9 % BUILDING COVERAGE: (N) RESIDENCE 2,307.96 SF TOTAL 2,307.96 SF 26.8 % < MAX. 40 % PARKING 2 COVERED SPACES SPECIAL INSPECTION CONSTRUCTION SHALL CONFORM TO: 2016 California Building Code 2016 California Residential Code 2016 California Plumbing Code 2016 California Mechanical Code 2016 California Electrical Code 2016 Energy Code 2016 Green Building Code 2016 California Fire Code 2016 California Reference Standards Code COVERSHEET GENERAL NOTES, CALGREEN CHECKLIST AND NOTES SHEET INDEX PROJECT DIRECTORY SCOPE OF WORK: DEMOLISH (E) 1,056 SF 1-STORY RESIDENCE. BUILD (N) 2,698.75 SF 2-STORY HOME. PROPERTY OWNER: Allan Coulson 16336 Shady View Ln Los Gatos, CA 95032 DESIGNER/CONTRACTOR: DE MATTEI CONSTRUCTION, INC. 1794 THE ALAMEDA SAN JOSE, CA. 95126 (408) 295-7516 SPECIAL INSPECTION NOTES LOCATION MAP PARCEL MAP 1 Scale: 1/8"=1'-0" PROPOSED SITE/ROOF PLAN ToDo: 1. PLACE HOLDER, BECAUSE IT WON'T FORMAT WITHOUT IT. SHEET INDEX CS COVER SHEET BLUEPRINT FOR A CLEAN BAY 1 TOPOGRAPHIC SURVEY C-1 COVER SHEET C-2 GRADING AND DRAINAGE PLAN C-3 DRAINAGE AND MISC. DETAILS C-4 EROSION CONTROL PLAN L1 LANDSCAPE PLAN A0.0 GENERAL NOTES A0.1 SITE DEMO AND TREE PROTECTION. A0.2 GREENPOINT RATED CHECKLIST A1.0 FLOOR AREA DIAGRAMS A2.1 PROPOSED FIRST FLOOR PLAN A2.2 PROPOSED SECOND FLOOR PLAN A3.1 PROPOSED EXTERIOR ELEVATIONS A3.2 PROPOSED EXTERIOR ELEVATIONS A4.1 PROPOSED SECTIONS A6.1 NEIGHBORHOOD PHOTOGRAPHS A6.2 SHADOW STUDY A6.3 SCHEMATIC NEIGHBORHOOD ELEVATIONS Coulson Residence PROJECT LOCATION NOTES: A. ROOF RAINWATER LEADERS ARE TO BE DISCHARGED ONTO SPLASH BLOCKS AND DIRECTED INTO LANDSCAPED AREAS. B. A SANITARY SEWER LATERAL CLEAN-OUT SHALL BE INSTALLED AT THE PROPERTY LINE, IF ONE DOES NOT ALREADY EXIST WITHIN TWO FEET OF THE PROPERTY LINE. C. All EXTERIOR LIGHTING WILL BE DOWNWARD DIRECTED. D. FIRE SPRINKLER SYSTEM WILL BE PROVIDED AND INSTALLED PER NFPA 13D 2016 ADDITION. E. PROJECT SIGN SHALL BE ORIENTED TOWARDS THE STREET,WITHIN 1' OF PROPERTY LINE OR 2' OF THE BACK OF SIDEWALK. THE TOP OF THE SIGN SHALL BE 5' FROM (E) GRADE. As shown 1 1 1 1 40 33 BOOK PAGE 1 1 1 N True North Project North 1 1 2 RESPONSES TO PLAN CHECK COMMENTS LL205/10/20192 2 2 2 2 EXHIBIT 18 BLUEPRINT FOR A CLEANBAYSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 5/22/2019 LL / JWDESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.As shown BYREVISIONS1" =10'9-28-2018NRSCALE:DATE:DRAWN BY:SHEET NO:JOB NO:1 SHEETSOFSANITARY SEWERCLEANOUTSANITARY SEWERMANHOLEFENCE LINEWATER METERWATER VALVEFIRE HYDRANTXX" TREEGUY ANCHORAS NOTEDJOINT POLETREE, SIZE AND TYPEWGCONCRETEWATER LINEGMGAS METERGAS LINEFL FLOWLINETC TOP OF CURBEP EDGE OF PAVEMENTCONC CONCRETELIP LIP OF GUTTERGS GROUND SHOTAD AREA DRAINTC TOP OF CURBFF FINISH FLOORBSL BUILDING SETBACK LINE BYREVISIONSN.T.S.12-2-2018NRSCALE:DATE:DRAWN BY:SHEET NO:JOB NO:4 SHEETSOFGENERAL NOTES: UTILITY NOTES:ABBREVIATIONDESCRIPTIONLEGENDNOTICE TO CONTRACTORSPERTINENT GRADING, PAVING AND TRENCH BACKFILL ON THIS SITE.RECOMMENDATIONS ON STRIPPING AND SITE PREPARATION FOR ALLEARTH WORK NOTE:THE CONTRACTOR SHALL STRICLY ADHERE TO THE SOILS ENGINEER'SNOTE:SHALL ESTABLISH HIS OWN QUANTITIES.THE QUANTITIES ARE SHOWN FOR THE PURPOSE OFGRADING PERMIT APPROVAL FROM THE TOWN OF LOS GATOS PUBLIC WORKS AND ARE NOT TO BE USED FOR PAYMENT TO THE CONTRACTOR . CONTRACTOR STANDARD GRADING NOTES“” 553520APPROXIMATE GRADING QUANTITIES (CU. YDS.)LOCATIONCUT DEPTH FILL DEPTHHOUSE5000 0SITE53 0.5'TOTAL553NOTE: NO GRADING REQUIRED EXCEPTFOR CRAWLSPACE & FOUNDATIONEXCAVATION & FOR SHAPING FINALGRADES FOR PROPER DRAINAGE1'2,5522,9715,523IMPERVIOUS COVERAGE (S.F.)BUILDINGSDRIVEWAY/WALKSTOTALEXISTINGREPLACEDNEW1,359 1,3273281481,6871,826TOTAL NEW & REPLACED IMPERVIOUS AREA=3,513 S.F.THE PROJECT GEOTECHNICALREPORT PREPARED BY:VICINITY MAPSITE SHANNON RDSHADY VIEW LANE DEL CARLO COURT BONNIE LANE HILOW RD NOBLE COURT HILOW COURTPOOL351 N- ADU12DNFUTUREPOOLFUTUREP.E.Q.DATEREVISIONS1" =10'12-2-2018NRSCALE:DATE:DRAWN BY:SHEET NO:JOB NO:4 SHEETSOFGRADING AND DRAINAGE CONSTRUCTION NOTES:LEGEND:DRAINAGE NOTEDRAINAGE NOTE 350360370350360370REVISIONSAS SHOWN12-2-2018NRSCALE:DATE:DRAWN BY:SHEET NO:JOB NO:4 SHEETSOFAREA DRAIN DETAILAAGRAVEL BASIN DETAILNOTES:TREE PROTECTION DETAILCONCRETE DRIVEWAY-TYPICAL SECTION ROOF DOWNSPOUT/SPLASH BLOCKINFILTRATION DEVICE DETAILFOOTING DRAINS SYSTEMSUBFLOOR DRAIN DETAILCATCH BASIN DETAILDATE BYREVISIONS1" =10'1-24-2019NRSCALE:DATE:DRAWN BY:SHEET NO:JOB NO:4 SHEETSOFTREE PROTECTION DETAILSTABILIZED CONSTRUCTION ENTRANCE NOTES: STABILIZED CONSTRUCTION ENTRANCELEGENDSTRAW WATTLESENTRENCHMENT IN FLAT AREASTRAW WATTLESDETAILBURLAP SACK DRAIN INLET (D.I.)SEDIMENT FILTER DETAILTEMPORARY CONCRETE WASHOUT FACILITY ( ABOVE GRADE)TEMPORARY COVER ON STOCK PILE11. “”“”NOTES: GENERAL NOTESSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A0.0DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.CALGREEN: JOINTS AND OPENINGS: ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENING WITH CEMENT MORTAR, CONCRETE MASONRY OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. A MINIMUM OF 75% OF THE CONSTRUCTION WASTE GENERATED AT THE SITE IS DIVERTED TO RECYCLE OR SALVAGE. THIS IS ACHIEVED EITHER BY USING CITY PRE-CERTIFIED LANDFILLS OR IMPLEMENTATION OF A WASTE MANAGEMENT PLAN. WASTE MANAGEMENT PLAN SHALL BE PRE-APPROVED BY ENVIRONMENTAL SERVICES DEPARTMENT. HEATING AND AIR CONDITIONING SYSTEM DESIGN SHALL BE SIZED, DESIGNED, AND HAVE THEIR EQUIPMENT SELECTED USING THE FOLLOWING METHODS: AHEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO ACCA MANUAL J, ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS . BHEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO ACCA MANUAL J, ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. CSELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ACCA 36-S MANUAL S OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHOD. DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL, OR OTHER ACCEPTABLE METHODS AT THE TIME OF ROUGH INSTALLATION OR DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT. ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AND AEROSOL PAINTS SHALL COMPLY WITH VOC AND OTHER CONTENT LIMITS. SPECIFIED IN SECTION 4.504 OF THE CGBSC. ALL PRODUCT CONTAINERS SHALL REMAIN ON SITE FOR FIELD VERIFICATION. PRIOR TO FINAL INSPECTION, A LETTER SIGNED BY THE GENERAL CONTRACTOR MUST BE PROVIDED TO THE BUILDING OFFICIAL CERTIFYING THAT ALL ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AEROSOL PAINTS, AEROSOL COATINGS, CARPET SYSTEMS (INCLUDING CARPETING, CUSHION, AND ADHESIVE), RESILIENT FLOORING SYSTEMS, AND COMPOSITE WOOD PRODUCTS INSTALLED ON THIS PROJECT ARE WITHIN THE EMISSION LIMITS SPECIFIED IN CGBSC SECTION 4.504 FINISHES: AUSE LOW-VOC INTERIOR WALL/CEILING PAINTS (<50 GRAMS PER LETTER (GPL) VOCS REGARDLESS OF SHEEN) CGBSC 4.504.2.2 BUSE LOW-VOC COATINGS THAT MEET SCAQMD RULE 1113 (CGBSC 4.504.2.3) CDOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT VOC FINISH MATERIALS HAVE BEEN USED PER CGBSC 4.504.2.4 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING, SHALL COMPLY WITH THE VOC- EMISSION LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) LOW-EMITTING MATERIALS LIST OR BE CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RCFI) FLOORSCORE PROGRAM. PARTICLEBOARD, MEDIUM DENSITY FIBERBOARD (MDF), AND HARDWOOD PLYWOOD USED IN INTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION STANDARDS. SPECIFY THE LIMITS ON THE PLANS IN ACCORDANCE WITH TABLE 4.504.5. VAPOR RETARDER AND CAPILLARY BREAK IS INSTALLED AT SLAB ON GRADE FOUNDATIONS. PRIOR TO ENCLOSING THE WALL AND FLOOR FRAMING, CONFIRMATION MUST BE PROVIDED TO THE BUILDING INSPECTOR SHOWING THE FRAMING MEMBERS DO NOT EXCEED 19% MOISTURE CONTENT IN ACCORDANCE WITH CGBSC SECTION 4.505.3 ALL PLUMBING FIXTURES AND FITTINGS SHALL MEET THE STANDARDS REFERENCED IN TABLE 1401.1 OF THE CURRENT CALIFORNIA PLUMBING CODE. ALL EXISTING TO REMAIN PLUMBING FIXTURES SHALL CONFORM TO THE FOLLOWING: ATOILETS WITH A FLOW RATE IN EXCESS OF 1.6 GPF SHALL BE REPLACED WITH TOILETS WITH A MAXIMUM OF 1.28 GPF. BSHOWER HEADS WITH A FLOW RATE GREATER THAN 2.5 GPM SHALL BE REPLACED WITH A MAXIMUM 2.0 GPM SHOWER HEAD. CLAVATORY AND KITCHEN FAUCETS WITH A FLOW RATE GREATER THAN 2.2 GPM SHALL BE REPLACED WITH A FAUCET WITH A MAXIMUM FLOW RATE OF 1.2 GPM (OR 1.8 GPM FOR KITCHEN FAUCETS). AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OCCUPANT OWNER. HVAC SYSTEMS INSTALLERS SHALL BE TRAINED AND CERTIFIED IN THE PROPER INSTALLATION OF HVAC SYSTEMS. SPECIAL INSPECTORS EMPLOYED BY THE ENFORCING AGENCY MUST BE QUALIFIED AND ABLE TO DEMONSTRATE COMPETENCE IN THE THE DISCIPLINE THEY ARE INSPECTING. DOCUMENTATION USED TO SHOW COMPLIANCE WITH THIS CODE SHALL INCLUDE BUT IS NOT LIMITED TO, CONSTRUCTION DOCUMENTS, PLANS, SPECIFICATIONS, BUILDER OR INSTALLER CERTIFICATION, INSPECTION REPORTS, OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY WHICH DEMONSTRATE SUBSTANTIAL CONFORMANCE. WHEN SPECIFIC DOCUMENTATION OR SPECIAL INSPECTION IS NECESSARY TO VERIFY COMPLIANCE, THAT METHOD OF COMPLIANCE WILL BE SPECIFIED IN THE APPROPRIATE SECTION OR IDENTIFIED IN THE APPLICATION CHECKLIST. ========================== MAY ONLY BE FOR LOS GATOS ========================== WASTE MANAGEMENT PLAN: A.PROVIDE A CONSTRUCTION WASTE MANAGEMENT PLAN FOR REVIEW AND APPROVAL IN ACCORDANCE WITH CGBSC SECTION 4.408.2. B.DOCUMENTATION SHALL BE PROVIDED, PRIOR TO FIRST INSPECTION, CONFIRMING COMPLIANCE TO THE WASTE WASTE MANAGEMENT PLAN PROVIDED TO THE JURISDICTION. CGBSC SECTION 4.408.2.1 C.A MANUAL, COMPACT DISC, WEB-BASED REFERENCE, OR OTHER ACCEPTABLE MEDIA INCLUDING THE CONSTRUCTION WASTE MANAGEMENT PLAN SHALL BE PLACED IN THE BUILDING PRIOR TO FINAL INSPECTION IN ACCORDANCE WITH CGBSC SECTION 4.410.1 updated 10/12/18address numbers CALGREEN: (ALT) FINISHES: A.USE LOW-VOC INTERIOR WALL/CEILING PAINTS (<50 GRAMS PER LETTER (GPL) VOCS REGARDLESS OF SHEEN) CGBSC 4.504.2.2 B.USE LOW-VOC COATINGS THAT MEET SCAQMD RULE 1113 (CGBSC 4.504.2.3) PLUMBING: ALL EXISTING TO REMAIN PLUMBING FIXTURES SHALL CONFORM TO THE FOLLOWING: A.TOILETS WITH A FLOW RATE IN EXCESS OF 1.6 GPF SHALL BE REPLACED WITH TOILETS WITH A MAXIMUM OF 1.28 GPF. B.SHOWER HEADS WITH A FLOW RATE GREATER THAN 2.5 GPM SHALL BE REPLACED WITH A MAXIMUM 2.0 GPM SHOWER HEAD. C.LAVATORY AND KITCHEN FAUCETS WITH A FLOW RATE GREATER THAN 2.2 GPM SHALL BE REPLACED WITH A FAUCET WITH A MAXIMUM FLOW RATE OF 1.2 GPM (OR 1.8 GPM FOR KITCHEN FAUCETS). WILDLAND-URBAN INTERFACE FIRE ZONEREQUIREMENTS PER CRC R327:PRIOR TO BUILDING PERMIT FINAL, THE PROPERTY SHALL BE IN A COMPLIANCE WITH THEVEGETATION MANAGEMENT REQUIREMENTS PRESCRIBED IN CALIFORNIA FIRE CODESECTION 4906, INCLUDING CALIFORNIA PUBLIC RESOURCES CODE 4291 OR CALIFORNIAGOVERNMENT CODE SECTION 51182 PER CRC R327.1.5. ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATIONOF LEAVES AND DEBRIS IN THE GUTTER PER CRC R327.5.4. EXTERIOR WALL COVERINGS SHALL EXTEND FROM THE TOP OF THE FOUNDATION TO THEROOF, AND TERMINATE AT 2 INCH NOMINAL SOLID WOOD BLOCKING BETWEEN RAFTERS AT ALL ROOF OVERHANGS, OR IN THE CASE OF ENCLOSED EAVES, TERMINATE AT THE ENCLOSURE PER CRC R327.7.3.1. THE EXPOSED UNDERSIDE OF ENCLOSED ROOF EAVES HAVING EITHER A BOXED-IN ROOF EAVE SOFFIT WITH A HORIZONTAL UNDERSIDE, OR SLOPING RAFTER TAILS WITH AN EXTERIOR COVERING APPLIED TO THE UNDERSIDE OF THE RAFTER TAILS, SHALL BE PROTECTED BY ONE OF THE FOLLOWING PER CRC R327.7.5: 30.1. NONCOMBUSTIBLE MATERIAL 30.2. IGNITION-RESISTANT MATERIAL 30.3. ONE LAYER OF 5/8” TYPE ‘X’ GYPSUM SHEATHING APPLIED BEHIND AN EXTERIOR COVERING ON THE UNDERSIDE OF THE RAFTER TAILS OR SOFFIT. 30.4. THE EXTERIOR PORTION OF A 1-HOUR FIRE RESISTIVE EXTERIOR WALL ASSEMBLY APPLIED TO THE UNDERSIDE OF THE RAFTER TAILS OR SOFFIT INCLUDING ASSEMBLIES USING THE GYPSUM PANEL AND SHEATHING PRODUCTS LISTED IN THE GYPSUM ASSOCIATION FIRE RESISTANT DESIGN MANUAL. 30.5. BOXED-IN ROOF EAVE SOFFIT ASSEMBLIES WITH A HORIZONTAL UNDERSIDE THAT MEET THE PERFORMANCE CRITERIA IN ACCORDANCE WITH THE TEST PROCEDURES SET FORTH IN SFM STANDARD 12-7A-3. EXTERIOR WINDOWS AND EXTERIOR GLAZED DOOR ASSEMBLIES SHALL COMPLY WITH ONE OF THE FOLLOWING REQUIREMENTS PER CRC R327.8.2.1: 31.1. BE CONSTRUCTED OF MULTI-PANE GLAZING WITH A MINIMUM OF ONE TEMPERED PANE MEETING THE REQUIREMENTS OF SECTION 2406 SAFETY GLAZING, OR 31.2. BE CONSTRUCTED OF GLASS BLOCK UNITS, OR 31.3. HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 20 MINUTES WHEN TESTED ACCORDING TO NFPA 257, OR 31.4. BE TESTED TO MEET THE PERFORMANCE REQUIREMENTS OF SFM STANDARD 12-7A-2. EXTERIOR DOORS SHALL COMPLY WITH ONE OF THE FOLLOWING PER CRC 327.8.3: 32.1. THE EXTERIOR SURFACE OR CLADDING SHALL BE OF NONCOMBUSTIBLE OR IGNITION- RESISTANT MATERIAL, OR 32.2. SHALL BE CONSTRUCTED OF SOLID CORE WOOD THAT COMPLY WITH THE FOLLOWING REQUIREMENTS: 32.2.1. STILES AND RAILS SHALL NOT BE LESS THAN 1 3/8 INCHES THICK 32.2.2. RAISED PANELS SHALL NOT BE LESS THAN 1 1/4 INCHES THICK, EXCEPT FOR THE EXTERIOR PERIMETER OF THE RAISED PANEL THAT MAY TAPER TO A TONGUE NOT LESS THAN 3/8 INCH THICK. 32.3. SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 20 MINUTES WHEN TESTED ACCORDING TO NFPA 252. 32.4. SHALL BE TESTED TO MEET THE PERFORMANCE REQUIREMENTS OF SFM STANDARD 12-7A-1. GARAGE: 1-HR SEPARATION BETWEEN DWELLING AND GARAGE PER CRC SECTION R302.6. 20 MINUTE, 1-3/4" SOLID WOOD FIRE RATED DOOR WITH SELF CLOSING AND SELF LATCHING DEVICES PER CRC SECTION R302.5 CODES: ALL HVAC EQUIPMENT, DUCT WORK AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE SECTIONS OF THE CURRENT MECHANICAL CODE, CALIFORNIA TITLE 24 STANDARDS AND MANUFACTURER'S SPECIFICATIONS. ALL PLUMBING WORK SHALL CONFORM WITH THE CURRENT CALIFORNIA PLUMBING CODE. SKYLIGHTS: ALL SKYLIGHTS ARE TO BE PRE-MANUFACTURED PLASTIC DOME TYPES WITH ANODIZED ALUMINUM FRAMES MOUNTED ON WOOD CURBS OR DIRECTLY TO ROOF DECK. FRAME COLOR IS TO MATCH OR BE SIMILAR TO THE ROOF COLOR. CURB HEIGHT ABOVE THE ADJACENT ROOF SURFACE IS TO BE 4" MINIMUM. THE DOME HEIGHT IS TO BE MINIMUM 5" OR 10% OF THE MAXIMUM SPAN OF THE DOME. SKYLIGHT UNITS SHALL MEET TITLE 24 REQUIREMENTS. SKYLIGHTS WITH INSTALLED GLAZING 12' ABOVE THE WALKING SURFACE SHALL BE CONSTRUCTED OF LAMINATED GLASS WITH A POLYVINYL BUTYRAL INTERLAYER AND A MINIMUM THICKNESS OF 0.030 INCHES (.76 mm) EXTERIOR PLASTER LATH: EXTERIOR PLASTER LATH SHALL BE OF AN APPROVED, PAPER-BACKED, CORROSION RESISTANT METAL OR WIRE FABRIC AND SHALL BE SELF FURRING. (1/4" MIN.) APPLY LATH OVER WALL UNDERLAYMENT WITH THE LONG DIMENSION HORIZONTAL AND LAP A MIN. 1/2" AT THE SIDES AND MIN. 1" AT THE ENDS. WHERE END LAPS OF SHEETS DO NOT OCCUR OVER SUPPORTS, THEY SHALL BE SECURELY TIED TOGETHER WITH A MIN. 18 GA. WIRE. REINFORCEMENT SHALL BE USED AT ALL CORNERS OR THE LATH SHALL BE CARRIED AROUND CORNERS AT LEAST ONE SUPPORT. A WEEP SCREED SHALL BE PROVIDED AT OR BELOW THE FOUNDATION LINE ON ALL EXTERIOR STUD WALLS A MIN. OF 4" ABOVE HIGHEST ADJACENT GRADE. THE SCREED SHALL ALLOW TRAPPED WATER TO DRAIN TO THE OUTSIDE. BOTH THE METAL LATH AND PAPER UNDERLAYMENT SHALL TERMINATE ON THE ATTACHMENT FLANGE OF THE SCREED. NAILING OF METAL LATH SHALL BE AT A MAX. OF 6 O.C. EACH WAY USING EITHER 11 GA. X 1-1/2" LONG X 7/16" HEAD NAILS OR 16 GA. STAPLES WITH 7/8" LEGS. GUARDRAILS: GUARDRAILS SHALL BE NOT LESS THAN 42 INCHES HIGH MEASURED VERTICALLY ABOVE THE LEADING EDGE OF THE TREAD, ADJACENT WALKING SURFACE OR ADJACENT SEATBOARD. GUARDRAILS SHALL BE ABLE TO RESIST A SINGLE CONCENTRATED LOAD OF 200 POUNDS, APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP AND HAVE ATTACHMENT DEVICES AND SUPPORTING STRUCTURE TO TRANSFER THIS LOADING TO THE APPROPRIATE STRUCTURAL ELEMENTS OF THE BUILDING. INTERMEDIATE RAILS (ALL THOSE EXCEPT THE HANDRAIL), BALUSTERS AND PANEL FILL ERS SHALL BE DESIGNED TO WITHSTAND A HORIZONTALLY APPLIED NORMAL LOAD OF 50 POUNDS ON AN AREA EQUAL TO ONE SQUARE FOOT, INCLUDING OPENING AND SPACE BETWEEN RAILS. OPEN GUARDRAIL AND STAIR RAILINGS SHALL HAVE INTERMEDIATE RAILS, BALUSTERS, PICKETS, ETC., ARRANGED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH THE OPENINGS. INSULATION: FIBERGLASS BATT INSULATION SHALL BE INSTALLED ACCORDING TO THE T-24 REPORT. SEE T-24 REPORT FOR INSULATION VALUES. LISTINGS: ALL HVAC EQUIPMENT AND ACCESSORIES SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LAB. INSTALLATION INSTRUCTIONS FOR ALL LISTED EQUIPMENT SHALL BE PROVIDED TO THE FIELD INSPECTOR AT TIME OF INSPECTION. EXHAUST FANS: ALL INTERIOR EXHAUST FANS SHALL PROVIDE 5 AIR CHANGES PER HOUR OR MORE. EXHAUST FANS AND FAN SYSTEMS SHALL HAVE BACK-DRAFT DAMPER CONTROLS. 1 HOUR WALLS: HVAC DUCTS PENETRATING ONE HOUR WALLS (GARAGE/HOUSE WALL) SHALL BE MINIMUM 26 GAUGE GALVANIZED STEEL. 1 HOUR SEPARATION BETWEEN DWELLING AND GARAGE PER CRC SECTION R302.6. GAS PIPING: GAS PIPING SHALL NOT BE IMBEDDED IN OR BELOW CONCRETE SLABS SEWER PIPING: PLASTIC OR PVC SEWER LINE SHALL BE PLACED WITH MIN. 6" OF SAND BASE AND COVER. FORCED AIR UNIT: FORCED AIR UNIT(S) SHALL BE INSTALLED PER THE MANUFACTURERS RECOMMENDATIONS AND THOSE OF THE STRUCTURAL ENGINEER WHEN INSTALLED IN AN ATTIC SPACE. GAS APPLIANCES: ALL GAS APPLIANCES AND EQUIPMENT SHALL HAVE INTERMITTENT IGNITION DEVICES WITH NO CONTINUOUS BURNING PILOTS. ALL APPLIANCES SHALL COMPLY WITH THE CURRENT CALIFORNIA MECHANICAL CODE. WATER HEATERS: WATER HEATERS SHALL BE INSULATED WITH EXTERNAL BLANKETS OF R-12 OF GREATER. INSULATE HOT WATER INLET AND OUTLET PIPES (FIRST FIVE FEET IN UNCONDITIONED SPACES) WITH EXTERNAL WRAPPING OF R-4 OR GREATER. WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST HORIZONTAL DISPLACEMENT DUE TO EARTHQUAKE MOTION. STRAPPING SHALL BE AT POINTS WITHIN THE UPPER 1/3 AND THE LOWER 1/3 OF ITS VERTICAL DIMENSIONS. AT THE LOWER POINT, A MINIMUM DISTANCE OF FOUR INCHES SHALL BE MAINTAINED ABOVE THE CONTROLS WITH THE STRAPPING. WATER HEATERS LOCATED IN NON-LIVING SPACES SHALL BE INSTALLED ON A PLATFORM SUCH THAT BURNERS AND BURNER-IGNITION DEVICES ARE LOCATED NOT LESS THAN EIGHTEEN INCHES ABOVE THE FINISHED FLOOR. TANKLESS WATER HEATERS: TANKLESS WATER HEATER SHALL BE INSTALLED PER MANUFACTURERS RECOMMENDATION. DRYER VENT: CLOTHES DRYERS SHALL VENT TO THE OUTSIDE OF THE BUILDING AND SHALL BE A MAXIMUM 14' IN LENGTH WITH TWO FEET REDUCTION FOR EACH 90 DEGREE ELBOW OVER TWO. PLUMBING VENTS: ALL PLUMBING VENTS SHALL BE MINIMUM 10 FEET FROM OPERABLE SKYLIGHTS. THERMOSTATS: ONLY "SETBACK" THERMOSTATS CERTIFIED BY THE CALIFORNIA ENERGY COMMISSION SHALL BE USED. HOSE BIBS: HOSE BIBS AND WATER OUTLETS WITH HOSE ATTACHMENTS SHALL HAVE APPROVED NON-REMOVABLE BACKFLOW PREVENTION DEVICES. FORCED AIR UNIT CLEARANCES: LISTED FURNACES SHALL BE INSTALLED IN CONFORMANCE WITH THE CONDITIONS OF THEIR LISTING. THE FURNACE INSTALLER SHALL LEAVE THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS ATTACHED TO THE APPLIANCE, CLEARANCES OF LISTED FURNACES FROM COMBUSTIBLES SHALL BE AS SPECIFIED IN THE LISTING OR ON THE FURNACE RATING PLATE. UNLISTED FURNACES SHALL HAVE THE FOLLOWING CLEARANCES FROM COMBUSTIBLES: ABOVE TOP OF CASING OR FURNACE 6" FROM TOP AND SIDES OF WARM-AIR BONNET OR PLENUM 6" FROM FRONT (UNLESS ACCESS REQUIREMENTS GREATER 18" FROM BACK OF FURNACE 6" FROM SIDES OF FURNACE 6" DISHWASHERS: DISHWASHING MACHINES CONNECTED DIRECTLY TO A DRAINAGE SYSTEM OR FOOD WASTE DISPOSAL SHALL HAVE AN APPROVED DISHWASHER AIR GAP FITTING ON THE DISCHARGE SIDE OF THE DISHWASHING MACHINE. LISTED AIR GAPS SHALL BE INSTALLED WITH THE FLOOD LEVEL (FL) MARKING AT OR ABOVE THE FLOOD LEVEL OF THE SINK/DRAIN BOARD, WHICH EVER IS HIGHER. TUB AND SHOWER VALVES: TUB AND SHOWER VALVES SHALL HAVE INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE QUICK ACTING VALVES: ALL BUILDING WATER SUPPLY SYSTEMS IN WHICH QUICK ACTING VALVES ARE INSTALLED (SUCH AS DISHWASHERS, CLOTHES WASHERS, ETC.) SHALL BE APPROVED WITH DEVICES AS CLOSE TO QUICK ACTING VALVES AS POSSIBLE TO ABSORB HIGH PRESSURES RESULTING FROM THE QUICK CLOSING OF THESE VALVES. DUCT TERMINATIONS: ALL ENVIRONMENTAL AIR DUCT TERMINATIONS SHALL BE A MINIMUM OF (3) FEET FROM PROPERTY LINES AND/OR ANY OPENINGS INTO THE BUILDING. WALL AND FLOOR FLASHING: ALL FLASHING AT WALLS, FLOORS, AND ROOF JUNCTURES TO VERTICAL SURFACES SHALL BE 26 GA. G.I. UNLESS NOTED OTHERWISE ON PLANS. FORM FABRICATE AND INSTALL FLASHING AS SHOWN ON DETAILS. SET ALL FLASHING IN PLASTIC CEMENT AND SET JOINTS IN BUTYL MASTIC. FLASHING SECTIONS SHALL HAVE AN END LAP OF 4" MIN. DOORS: ALL EXTERIOR DOORS ARE TO BE FULLY WEATHER- STRIPPED, CERTIFIED AND LABELED FOR COMPLIANCE TO ENERGY CONSERVATION REGULATIONS. ALL FRENCH DOORS SHALL BE PAINT GRADE WOOD WITH TEMPERED, DOUBLE GLASS PANELS ARRANGED AS SHOWN ON PLANS AND DOOR SCHEDULE. WINDOWS: ALL WINDOWS SHALL BE FULLY WEATHER-STRIPPED, CERTIFIED AND LABELED FOR COMPLIANCE TO ENERGY CONSERVATION REGULATIONS. ALL WINDOWS ARE TO BE WOOD OR VINYL FRAMED. DOUBLE GLAZED WITH PANES AS SHOWN ON PLANS AND WINDOW SCHEDULE AND A MAXIMUM U-VALUE AS SET FORTH IN THE T-24 ENERGY CALCULATIONS. BATH COUNTER TOPS: ALL BATH COUNTERTOPS AND SPLASHES SHALL BE CERAMIC TILE AS SELECTED BY OWNER UNLESS NOTED OTHERWISE ON THE PLANS. USE GRANITE OR MARBLE TILES OR SLAB WHERE NOTED ON PLANS AND INTERIOR ELEVATIONS. WEATHER BARRIER: ALL WEATHER EXPOSED WALL SURFACES SHALL BE PROTECTED WITH AN UNDERLAYMENT OF (2) LAYERS GRADE "D" BUILDING PAPER OVER PLYWOOD WALL SHEATHING. UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION WITH MIN. 2" LAP AT HORIZONTAL JOINTS AND MIN. 6" LAP AT VERTICAL JOINTS. UNDERLAYMENT SHALL BE FREE OF HOLES AND BREAKS OTHER THAN THOSE FROM NAILING TO PLYWOOD SHEATHING OR WALL STUDS. ARCHITECTURAL (CONT.) CAULKING: ALL JOINTS AND PENETRATIONS AT EXTERIOR WALLS, CEILINGS AND FLOOR ASSEMBLIES SHALL BE FULLY CAULKED AND SEALED. TUBS & SHOWERS: SHOWERS SHALL BE A MIN. SIZE OF 1024 SQ.IN AND ACCOMMODATE AT 30" CIRCLE. BACKER FOR SHOWER AND TUB SHOWER WALLS TO BE FIBER-CEMENT, FIBER REINFORCED CEMENTITIOUS BACKER UNITS, GLASS MAT GYPSUM BACKERS OR FIBER-REINFORCED GYPSUM BACKERS TO A MIN. HEIGHT OF 72" ABOVE THE FLOOR. SHOWER WALLS SHALL BE FINISHED WITH CERAMIC TILE OF OTHER SMOOTH, HARD NON-ABSORBENT COVERING. ALL TUB AND SHOWER GLAZING SHALL BE MADE OF SHATTER-RESISTANT TEMPERED GLASS. SWING DOORS SHALL OPEN OUTWARD WITH A MIN. OPENING CLEARANCE OF 22". PRE-FABRICATED FIREPLACES: PRE-FABRICATED METAL FIREPLACES SHALL BE INSTALLED WITH INSULATED CHIMNEY FLUE, SPARK ARRESTOR AND ACCESSORIES ACCORDING TO MANUFACTURERS SPECIFICATIONS. FIREPLACE OPENING SHALL BE EQUIPPED WITH A TIGHT FITTING, CLOSEABLE METAL OR GLASS DOOR. FIREPLACE SHALL HAVE A FLUE DAMPER AND AN OUTSIDE AIR INTAKE WITH DAMPER. ONLY GAS APPLIANCE FIREPLACES ARE TO BE USED. GLAZING: ALL GLAZING SHALL CONFORM TO FEDERAL GLAZING REGULATIONS AND THE CALIFORNIA RESIDENTIAL CODE. GLAZING IN HAZARDOUS LOCATIONS SHALL BE FULLY TEMPERED GLASS OR APPROVED PLASTIC AND IS PERMANENTLY IDENTIFIED BY THE MANUFACTURER OR INSTALLER. MECHANICAL ROOM DOORS: ACCESS DOORS OF THE MECHANICAL ROOM SHALL BE SOLID CORE WITH MINIMUM 100 SQ. IN. LOUVERED VENT AT TOP OF DOORS AND MINIMUM 100 SQ. IN. LOUVERED VENT AT BOTTOM OF DOORS. GYPSUM WALLBOARD: ALL INTERIOR WALL AND CEILING FACES ARE TO BE SHEATHED WITH 1/2" GYPSUM WALLBOARD EXCEPT WHERE NOTED TO USE 5/8" TYPE "X" WALLBOARD. TAPE, TEXTURE AND PAINT GYP. BOARD ACCORDING TO FINISH SCHEDULE. ALL GAPS AND PENETRATIONS AT 5/8" TYPE "X" WALLBOARD SHALL BE FILLED WITH TAPING CEMENT. NAIL ALL GYP. BOARD TO WALL STUDS, PLATES, BLOCKING, ETC., AS FOLLOWS: 1/2" WALLBOARD 4d CEMENT COATED BOX NAIL OR 1-3/8" x 14 GA. ACID-ETCHED, PHOSPHATE COATED NAIL OR 4d "DRYVITE" NAIL AT 7" O.C. 5/8" TYPE "X" WALLBOARD 6D "COOLER" NAILS AT 7" O.C. ROOF VENTILATION: THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE OR 1/300 OF THE VENTED SPACE PROVIDED ONE OR MORE OF THE FOLLOWING CONDITIONS ARE MET: 1.IN CLIMATE ZONES 14 AND 16, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. 2.AT LEAST 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. ALL VENT OPENINGS SHALL BE COVERED WITH CORROSION RESISTANT, NON-COMBUSTIBLE METAL MESH WITH MESH OPENINGS OF AT LEAST 1/16" AND A MAXIMUM OF 1/8" DIMENSION. VENTS SHALL BE LOCATED SO AS TO PROVIDE CROSS VENTILATION OF EACH SEPARATE ATTIC SPACE AND SHALL PROTECT AGAINST THE ENTRANCE OF RAIN AND SNOW. STAIR HANDRAILS: EVERY STAIRWAY OF 4 OR MORE RISERS SHALL HAVE AT LEAST ONE HANDRAIL AND EVERY OPEN SIDE OF A STAIRWAY SHALL HAVE A GUARDRAIL. HANDRAILS MOUNTED ON A WALL SHALL HAVE A MIN. 1-1/2" SPACE BETWEEN THE WALL AND THE HANDRAIL. THE HANDGRIP PORTION OF HANDRAILS SHALL BE BETWEEN 1-1/4' AND 2" CROSS SECTION DIMENSION AND SHALL HAVE A SMOOTH SURFACE WITH NO SHARP CORNERS. ALL HANDRAILS ARE TO BE PLACED 34" AND 38" ABOVE TREAD NOSING AND SHALL BE CONTINUOUS THE FULL LENGTH OF THE STAIRS. EXTERIOR PLASTER: EXTERIOR PLASTER SHALL BE PORTLAND CEMENT APPLIED IN THREE COATS TO A MIN. THICKNESS OF 7/8". SEE EXTERIOR ELEVATIONS FOR TEXTURE VARIATIONS. APPLIANCES: THE CONTRACTOR SHALL PROVIDE RESIDENTIAL EQUIPMENT WHICH IS U.L. LABELED. PROVIDE, TO THE OWNER, ALL MANUFACTURER'S STANDARD WRITTEN WARRANTIES, OWNER'S MANUALS, AND STANDARD ACCESSORIES. CONTRACTOR SHALL INSTALL THE APPLIANCES WHERE INDICATED ON DRAWINGS AND AS REQUIRED BY ALL CODES AND LISTINGS. APPLIANCE TYPES, STYLES, COLORS, ETC., SHALL BE SELECTED BY OWNER. EMERGENCY EGRESS ESCAPE AND RESCUE WINDOWS: BASEMENTS OF DWELLING UNITS AND EVERY BEDROOM BELOW THE 4TH STORY SHALL HAVE AT LEAST ONE OPERABLE WINDOW OR DOOR APPROVED FOR EMERGENCY ESCAPE AND RESCUE DIRECTLY TO EXTERIOR. THE UNITS SHALL BE OPERABLE TO PROVIDE FULL CLEAR OPENING WITHOUT THE USE OF SEPARATE TOOLS AND HAVE A NET CLEAR OPENING OF NO LESS THAN 5.7 SQUARE FEET. THE NET CLEAR OPENING HEIGHT SHALL BE A MINIMUM OF 24" AND THE WIDTH SHALL BE A MINIMUM OF 20" WITH THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44" MEASURED FROM THE FLOOR IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72” ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM 24” ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED. OPERABLE SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4 INCH DIAMETER WHERE SUCH OPENING ARE LOCATED WITHIN 24” OF THE FINISHED FLOOR. WHERE SUCH WINDOW OPENINGS DO NOT COMPLY, WINDOW FALL PREVENTION DEVICES AND WINDOW GUARDS THAT COMPLY WITH ASTM F 2090, SHALL BE PROVIDED. STREET ADDRESS: NEW AND EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED ADDRESS IDENTIFICATION. THE ADDRESS IDENTIFICATION SHALL BE LEGIBLE AND PLACED IN A POSITION THAT IS VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. ADDRESS IDENTIFICATION CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE ARABIC NUMBERS OR ALPHABETICAL LETTERS. NUMBERS SHALL NOT BE SPELLED OUT. EACH CHARACTER SHALL BE NOT LESS THAN 4 INCHES HIGH WITH A MINIMUM STROKE WIDTH OF 1 /2 INCH. SPARK ARRESTORS: SPARK ARRESTORS SHALL BE INSTALLED ON ALL CHIMNEYS INCLUDING OUTSIDE FIREPLACES. CODES: ALL ELECTRICAL EQUIPMENT, WIRING AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE SECTIONS OF THE NATIONAL ELECTRICAL CODE, CALIFORNIA TITLE 24 STANDARDS AND THE MANUFACTURER'S SPECIFICATIONS. LISTINGS: ALL ELECTRICAL EQUIPMENT AND ACCESSORIES SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LAB. INSTALLATION INSTRUCTIONS FOR ALL LISTED EQUIPMENT SHALL BE PROVIDED TO THE FIELD INSPECTOR AT TIME OF INSPECTION. RECESSED FIXTURES: PROVIDE RECESSED FIXTURE CLEARANCE PER CODE. RECESSED FIXTURES IN INSULATED CEILINGS SHALL BE "IC" APPROVED FIXTURES. DRYER LOADS: CLOTHES DRYER LOADS SHALL BE DETERMINED ON A LOAD OF 5000 WATTS PER APPLIANCE OR BY NAMEPLATE RATING. ELECTRICAL BOXES: ELECTRIC SWITCH AND OUTLET BOXES ON EXTERIOR WALLS SHALL HAVE RUBBER GASKETS FOR MEDIUM INFILTRATION CONTROL. KITCHEN AND BATH FIXTURES: ALL GENERAL LIGHTING FIXTURES AND BULBS IN KITCHEN AND BATH AREAS SHALL HAVE AN EFFICACY RATING OF 40 LUMENS PER WATT OR GREATER. FLUORESCENT FIXTURES WITH PLUG-IN (NOT SCREW-IN) FLUORESCENT LAMPS SHALL BE USED. CLOSET LIGHTS: LIGHT FIXTURES IN CLOSETS/WARDROBES SHALL HAVE A MIN. 18" HORIZONTAL CLEARANCE TO SHELVES. TUB/SHOWER LIGHTS: LIGHT FIXTURES MOUNTED WITHIN 5' OF A SPA/ TUB SHALL BE MOUNTED AT LEAST 7'6" ABOVE THE MAXIMUM WATER LEVEL OF THE SPA/TUB AND SHALL BE GFCI PROTECTED. DRYER/COOKING UNIT OUTLETS: CLOTHES DRYERS AND COOKING UNITS SHALL HAVE CONDUCTOR WIRES WITH AN INSULATED NEUTRAL AND FOUR-PRONG OUTLET. OUTDOOR OUTLETS: PROVIDE OUTSIDE RECEPTACLES AT THE FRONT AND REAR OF THE HOME WITHIN 6'-6" OF GRADE WHICH ARE WATERPROOF AND GFCI PROTECTED. SEE PLAN FOR LOCATIONS. KITCHEN BRANCH CIRCUITS: SHALL BE PROTECTED BY ARC-FAULT CIRCUIT INTERRUPTERS. PROVIDE (2) SMALL APPLIANCE BRANCH CIRCUITS IN THE KITCHEN WHICH ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETS. THESE OUTLETS CANNOT SERVE DINING ROOM, OUTSIDE PLUGS, RANGE HOOD, DISPOSALS, DISHWASHERS OR MICROWAVES. ONLY THE REQUIRED COUNTERTOP/ WALL OUTLETS (INCLUDING REFRIGERATOR). BATHROOM OUTLET CIRCUITS: REQUIRED BATHROOM OUTLETS SHALL BE ON A DEDICATED 20 AMP CIRCUIT WHICH CANNOT SERVE ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. TAMPER-RESISTANT RECEPTACLES IN DWELLING UNITS: ALL NEW NON-LOCKING TYPE 125-VOLT, 15- AND 20-AMPERE RECEPTACLES THAT ARE WITHIN 5 1/2' ABOVE FINISH FLOOR SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES. ARCHITECTURAL MECHANICAL ELECTRICAL GENERAL NOTES JOINTS AND OPENINGS: ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENING WITH CEMENT MORTAR, CONCRETE MASONRY OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. A MINIMUM OF 75% OF THE CONSTRUCTION WASTE GENERATED AT THE SITE IS DIVERTED TO RECYCLE OR SALVAGE. THIS IS ACHIEVED EITHER BY USING CITY PRE-CERTIFIED LANDFILLS OR IMPLEMENTATION OF A WASTE MANAGEMENT PLAN. WASTE MANAGEMENT PLAN SHALL BE PRE-APPROVED BY ENVIRONMENTAL SERVICES DEPARTMENT. HEATING AND AIR CONDITIONING SYSTEM DESIGN SHALL BE SIZED, DESIGNED, AND HAVE THEIR EQUIPMENT SELECTED USING THE FOLLOWING METHODS: A HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO ACCA MANUAL J, ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS . B HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO ACCA MANUAL J, ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. C SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ACCA 36-S MANUAL S OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHOD. DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL, OR OTHER ACCEPTABLE METHODS AT THE TIME OF ROUGH INSTALLATION OR DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT. ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AND AEROSOL PAINTS SHALL COMPLY WITH VOC AND OTHER CONTENT LIMITS. SPECIFIED IN SECTION 4.504 OF THE CGBSC. ALL PRODUCT CONTAINERS SHALL REMAIN ON SITE FOR FIELD VERIFICATION. PRIOR TO FINAL INSPECTION, A LETTER SIGNED BY THE GENERAL CONTRACTOR MUST BE PROVIDED TO THE BUILDING OFFICIAL CERTIFYING THAT ALL ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AEROSOL PAINTS, AEROSOL COATINGS, CARPET SYSTEMS (INCLUDING CARPETING, CUSHION, AND ADHESIVE), RESILIENT FLOORING SYSTEMS, AND COMPOSITE WOOD PRODUCTS INSTALLED ON THIS PROJECT ARE WITHIN THE EMISSION LIMITS SPECIFIED IN CGBSC SECTION 4.504 FINISHES: A USE LOW-VOC INTERIOR WALL/CEILING PAINTS (<50 GRAMS PER LETTER (GPL) VOCS REGARDLESS OF SHEEN) CGBSC 4.504.2.2 B USE LOW-VOC COATINGS THAT MEET SCAQMD RULE 1113 (CGBSC 4.504.2.3) C DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT VOC FINISH MATERIALS HAVE BEEN USED PER CGBSC 4.504.2.4 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING, SHALL COMPLY WITH THE VOC- EMISSION LIMITS DEFINED IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) LOW-EMITTING MATERIALS LIST OR BE CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RCFI) FLOORSCORE PROGRAM. PARTICLEBOARD, MEDIUM DENSITY FIBERBOARD (MDF), AND HARDWOOD PLYWOOD USED IN INTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION STANDARDS. SPECIFY THE LIMITS ON THE PLANS IN ACCORDANCE WITH TABLE 4.504.5. VAPOR RETARDER AND CAPILLARY BREAK IS INSTALLED AT SLAB ON GRADE FOUNDATIONS. PRIOR TO ENCLOSING THE WALL AND FLOOR FRAMING, CONFIRMATION MUST BE PROVIDED TO THE BUILDING INSPECTOR SHOWING THE FRAMING MEMBERS DO NOT EXCEED 19% MOISTURE CONTENT IN ACCORDANCE WITH CGBSC SECTION 4.505.3 ALL PLUMBING FIXTURES AND FITTINGS SHALL MEET THE STANDARDS REFERENCED IN CA CIVIL CODE SECTIONS 1101.01-1101.8. ALL EXISTING TO REMAIN PLUMBING FIXTURES SHALL CONFORM TO THE FOLLOWING: A TOILETS WITH A FLOW RATE IN EXCESS OF 1.6 GPF SHALL BE REPLACED WITH TOILETS WITH A MAXIMUM OF 1.28 GPF. B SHOWER HEADS WITH A FLOW RATE GREATER THAN 2.5 GPM SHALL BE REPLACED WITH A MAXIMUM 1.8 GPM SHOWER HEAD. C LAVATORY AND KITCHEN FAUCETS WITH A FLOW RATE GREATER THAN 2.2 GPM SHALL BE REPLACED WITH A FAUCET WITH A MAXIMUM FLOW RATE OF 1.2 GPM (OR 1.8 GPM FOR KITCHEN FAUCETS). AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OCCUPANT OWNER. HVAC SYSTEMS INSTALLERS SHALL BE TRAINED AND CERTIFIED IN THE PROPER INSTALLATION OF HVAC SYSTEMS. SPECIAL INSPECTORS EMPLOYED BY THE ENFORCING AGENCY MUST BE QUALIFIED AND ABLE TO DEMONSTRATE COMPETENCE IN THE THE DISCIPLINE THEY ARE INSPECTING. DOCUMENTATION USED TO SHOW COMPLIANCE WITH THIS CODE SHALL INCLUDE BUT IS NOT LIMITED TO, CONSTRUCTION DOCUMENTS, PLANS, SPECIFICATIONS, BUILDER OR INSTALLER CERTIFICATION, INSPECTION REPORTS, OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY WHICH DEMONSTRATE SUBSTANTIAL CONFORMANCE. WHEN SPECIFIC DOCUMENTATION OR SPECIAL INSPECTION IS NECESSARY TO VERIFY COMPLIANCE, THAT METHOD OF COMPLIANCE WILL BE SPECIFIED IN THE APPROPRIATE SECTION OR IDENTIFIED IN THE APPLICATION CHECKLIST. DIMENSIONS: ALL EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING. ALL INTERIOR DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED. CALGREEN: ARC-FAULT AND GROUND FAULT OUTLETS: ARC-FAULT (AFCI) REQUIRED IN FAMILY ROOMS , DINING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUN ROOMS, REC ROOMS, CLOSETS, AND HALLWAYS AND LIGHTING. GROUND FAULT (GFCI) IS REQUIRED IN BATHROOMS, GARAGES, ACCESSORY AREAS, EXTERIOR, CRAWLSPACES, BASEMENTS, DISHWASHERS, AND DISPOSALS. COMBINATION AFCI/GFCI IS REQUIRED IN KITCHENS, AND LAUNDRY AREAS. ELECTRICAL (CONT.) A.FIRE SPRINKLER SYSTEM WILL BE PROVIDED AND INSTALLED PER NFPA 13D 2016 ADDITION. B.FIRE SPRINKLERS REQUIRED: AN AUTOMATIC RESIDENTIAL FIRE SPRINKLER SYSTEM SHALL BE INSTALLED IN ONE AND TWO-FAMILY DWELLINGS AS FOLLOWS: IN ALL NEW ONE AND TWO-FAMILY DWELLINGS AND IN EXISTING ONE AND TWO-FAMILY DWELLINGS WHEN ADDITIONS ARE MADE THAT INCREASE THE BUILDING AREA TO MORE THAN 3,600 SQUARE FEET. NOTE: THE OWNER(S), OCCUPANT(S) AND ANY CONTRACTOR(S) OR SUBCONTRACTOR(S) ARE RESPONSIBLE FOR CONSULTING WITH THE WATER PURVEYOR OF RECORD IN ORDER TO DETERMINE IF ANY MODIFICATION OR UPGRADE OF THE EXISTING WATER SERVICE IS REQUIRED. A STATE OF CALIFORNIA LICENSED (C-16) FIRE PROTECTION CONTRACTOR SHALL SUBMIT PLANS, CALCULATIONS, A COMPLETED PERMIT APPLICATION AND APPROPRIATE FEES TO THIS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO BEGINNING THEIR WORK. CRC SEC. 313.2 AS ADOPTED AND AMENDED BY LGTC. C.WATER SUPPLY REQUIREMENTS: POTABLE WATER SUPPLIES SHALL BE PROTECTED FROM CONTAMINATION CAUSED BY FIRE PROTECTION WATER SUPPLIES. IT IS THE RESPONSIBILITY OF THE APPLICANT AND ANY CONTRACTORS AND SUBCONTRACTORS TO CONTACT THE WATER PURVEYOR SUPPLYING THE SITE OF SUCH PROJECT, AND TO COMPLY WITH THE REQUIREMENTS OF THAT PURVEYOR. SUCH REQUIREMENTS SHALL BE INCORPORATED INTO THE DESIGN OF ANY WATER- BASED FIRE PROTECTION SYSTEMS, AND/OR FIRE SUPPRESSION WATER SUPPLY SYSTEMS OR STORAGE CONTAINERS THAT MAY BE PHYSICALLY CONNECTED IN ANY MANNER TO AN APPLIANCE CAPABLE OF CAUSING CONTAMINATION OF THE POTABLE WATER SUPPLY OF THE PURVEYOR OF RECORD. FINAL APPROVAL OF THE SYSTEM(S) UNDER CONSIDERATION WILL NOT BE GRANTED BY THIS OFFICE UNTIL COMPLIANCE WITH THE REQUIREMENTS OF THE WATER PURVEYOR OF RECORD ARE DOCUMENTED BY THAT PURVEYOR AS HAVING BEEN MET BY THE APPLICANT(S). 2016 CFC SEC. 903.3.5 AND HEALTH AND SAFETY CODE 13114.7 D.ADDRESS IDENTIFICATION: NEW AND EXISTING BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. THESE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, ADDRESS NUMBERS SHALL BE PROVIDED IN ADDITIONAL APPROVED LOCATIONS TO FACILITATE EMERGENCY RESPONSE. ADDRESS NUMBERS SHALL BE ARABIC NUMBERS OR ALPHABETICAL LETTERS. NUMBERS SHALL BE A MINIMUM OF 4 INCHES (101.6 MM) HIGH WITH A MINIMUM STROKE WIDTH OF 0.5 INCH (12.7 MM). WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. ADDRESS NUMBERS SHALL BE MAINTAINED. CFC SEC. 505.1 E.CONSTRUCTION SITE FIRE SAFETY: ALL CONSTRUCTION SITES MUST COMPLY WITH APPLICABLE PROVISIONS OF THE CFC CHAPTER 33 AND OUR STANDARD DETAIL AND SPECIFICATION S1-7. PROVIDE APPROPRIATE NOTATIONS ON SUBSEQUENT PLAN SUBMITTALS, AS APPROPRIATE TO THE PROJECT. CFC CHP. 33 F.WILDLAND URBAN INTERFACE:THIS PROJECT IS LOCATED WITHIN THE DESIGNATED WILDLAND- URBAN INTERFACE FIRE AREA. THE BUILDING CONSTRUCTION SHALL COMPLY WITH THE PROVISIONS OF SECTION R327 OF THE CALIFORNIA RESIDENTIAL CODE OR THE CALIFORNIA BUILDING CODE (CBC) CHAPTER 7A., AS APPLICABLE. VEGETATION CLEARANCE SHALL BE IN COMPLIANCE WITH CBC SECTION 701A.3.2.4 PRIOR TO PROJECT FINAL APPROVAL. FIRE NOTES: NOTE: ALL OUTDOOR LIGHTING AFFIXED TO THE BUILDING SHALL BE DOWNWARD DIRECTED AND SHIELDED SO THAT NO LIGHT GLARE WILL ENCROACH ONTO NEIGHBORING PROPERTIES. 1 Scale: None TYP. OUTDOOR LIGHT (O.L.) As shown cLcLWWWW WWW W W 8'-0" SIDE SETBACK25'-0" FRONT SETBACK 15'-0" STREET SETBACK20'-0" REAR SETBACK 61'-0"8'-0"1'-0"PROPERTY LINE 142.27'PROPERTY 66.37'PROPERTY 118.52'PROPERTY 39.98'SHADY VIEW LN. (60' R.O.W.)SHANNON RD.(50' R.O.W.)(E) 26.4" OAK TREE TO REMAIN. (E) 45" REDWOOD PINE TO REMAIN. (E) 45" REDWOOD PINE TO REMAIN. (E) FIRE HYDRANT TO REMAIN. SSCO SDMH (E) JP (E) JP (E) ELEC. METER TO BE REMOVED. (E) GAS METER TO BE REMOVED. EDGE PAVEMENT ROLLED CURBEDGE PAVEMENTEDGE PAVEMENT ROLLED CURB (E) WATER METER TO BE RELOCATED. (E) 27" SMOKE TREE TO REMAIN. SSCO (E) CLEAN OUT TO BE RELOCATED. (E) HEDGE TO BE REMOVED. (E) 18" CYPRESS TO BE REMOVED. (E) 18" CYPRESS TO BE REMOVED. TYPE "III" TREE PROTECTION. SEE FIGURE 3 THIS PAGE. (E) CANOPY DRIPLINE, TYP. TYPE "I" TREE PROTECTION. SEE FIGURE 1 THIS PAGE. TYPE "I" TREE PROTECTION. SEE FIGURE 1 THIS PAGE. TYPE "III" TREE PROTECTION. SEE FIGURE 3 THIS PAGE. TYPE "III" TREE PROTECTION. SEE FIGURE 3 THIS PAGE. (E)EXISTING NON- CONFORMING POOL HOUSE9' HEIGHT.2 1/2 : 12APPROXIMATE LOCATION OF (E) 1-STORY HOME AT 16344 SHADY VIEW LN. APPROXIMATE LOCATION OF (E) 2-STORY HOME AT 16330 SHANNON RD. (E) 1-STORY HOUSE TO BE REMOVED SHOWN SHADED (E) SHED TO BE REMOVED. (E) SHED TO BE REMOVED. (E) SHED TO BE REMOVED.SSSSSSSSSSSSSSSSSSSSSS SS SS SSSDSDSDSDSDSDSDSD SDSDSDSDSDSD SDSDSDSITE DEMO AND TREEPROTECTION.SHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A0.1DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.1 Scale: 1/8"=1'-0" SITE DEMOLITION/TREE PROTECTION PLAN 2 No Scale TREE PROTECTION DIAGRAM S SEE CIVIL SHEET C-0 FOR M ORE INFORMATION As shownRESPONSES TO PLAN CHECK COMMENTSLL03/26/201911 1 1 N True North Project North 1 GREENPOINT RATEDCHECKLISTSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A0.2DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.As shown 6 '-9 1 /2 "1'-10 1/2"20'-6"8'-1 1/2"18'-7 1/4" 11'-6"8'-8 1/4"9'-7 1/2"37'-11 1/4"5'-2 1/4"13'-11"14'-2 3/4" 9'-7 1/4"20'-10 1/4"HALL FAMILY DININGBATH ENTRY KITCHEN GARAGE OFFICE UTILITYBALCONY ABOVEF.P. A B C D E F G H J CLOSET DECK BEDROOM BATH CLOSET F.P. OPEN ABOVE OPEN ABOVE 1 2 DN (under a separate permit)(under a separate permit)2'-8"13'-11 3/4"20'-10 1/4"13'-9 1/2"18'-2"16'-5 1/2"40'-8 1/4"5'-5"6'-4 1/4"4'-3 3/4" 5'-5 3/4" BATH BEDROOM BATH BALCONY OPEN BELOW BEDROOM CLO. LAUNDRY HALL MASTER BDRM BATH OPEN BELOW BALCONY HALL CLOSET K L M N Q P CLO.CLO.FLOOR AREA DIAGRAMSSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A1.0DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.FIRST FLOOR: LETTER WIDTH LENGTH AREA B 8'-1 1/2"20'-10 1/4"167.58 C 18'-7 1/4"37'-11 1/4"705.80 D 11'-6"5'-2 1/4"59.66 E 11'-6"8'-8 1/4"49.95 F radius=6'-9 1/2"72.46 G 9'-7 1/2"13'-11"133.95 H 14'-2 3/4"15'-6 1/2"221.14 J radius=1'-10 1/2"14.55 FIRST FLOOR TOTAL 1,425.08 SF SECOND FLOOR: LETTER WIDTH LENGTH AREA K 13'-11 3/4"20'-10 1/4"291.52 L 13'-9 1/2"18'-2"250.55 M radius=2'-8"5.59 N 5'-5 3/4"5'-5"29.68 P 40'-8 1/4"16'-5 1/2"669.65 Q 4'-3 3/4"6'-4 1/4"26.68 SECOND FLOOR TOTAL 1,273.67 SF TOTAL FLOOR AREA 2,698.75 SF A - GARAGE FLOOR AREA 422.81 SF 1 Scale: 3/16"=1'-0" PROPOSED FIRST FLOOR PLAN 2 Scale: 3/16"=1'-0" PROPOSED SECOND FLOOR PLAN FIRST FLOOR: LETTER WIDTH LENGTH AREA A (GARAGE)20'-6"20'-7 1/2"422.81 B 8'-1 1/2"20'-7 1/2"167.58 C 18'-7 1/4"37'-11 1/4"705.80 D 11'-6 "5'-2 1/2"59.90 E 11'-6 "5'-2 1/2"59.90 F radius=6'-9 1/2"72.46 G 9'-7 1/2"13'-11"133.95 H 31'-7 3/4"15'-6 1/2"491.83 I radius=1'-10 1/2"14.55 FIRST FLOOR TOTAL 1,705.95 SF SECOND FLOOR: LETTER WIDTH LENGTH AREA K 13'-11 3/4"20'-10 1/4"291.52 L 13'-9 1/2"18'-2"250.55 M radius=2'-8"5.59 N 5'-5 3/4"5'-5"99.54 O 4'-3 3/4"6'-2 1/4"26.68 P 40'-8 1/4"16'-5 1/2"669. Q (BALCONY)5'-0 1/2"20'-10 1/4"187.50 R (BALCONY)12'-6"15'-0"105.14 SECOND FLOOR TOTAL 1,343.53 SF ADU: S 20'-4 3/4"25'-2"513.30 SF TOTAL FLOOR AREA 3,562.78 SF GARAGE FLOOR AREA 422.81 SF As shown FIRST FLOOR: LETTER WIDTH LENGTH AREA B 8'-1 1/2"20'-7 1/2"167.58 C 18'-7 1/4"37'-11 1/4"705.80 D 11'-6"5'-2 1/4"59.66 E 11'-6"8'-8 1/4"49.95 F radius=6'-9 1/2"72.46 G 9'-7 1/2"13'-11"133.95 H 14'-2 3/4"15'-6 1/2"221.14 J radius=1'-10 1/2"14.55 FIRST FLOOR TOTAL 1,425.08 SF SECOND FLOOR: LETTER WIDTH LENGTH AREA K 13'-11 3/4"20'-10 1/4"291.52 L 13'-9 1/2"18'-2"250.55 M radius=2'-8"5.59 N 5'-5 3/4"5'-5"29.68 P 40'-8 1/4"16'-5 1/2"669.65 Q 4'-3 3/4"6'-2 1/4"26.68 SECOND FLOOR TOTAL 1,273.67 SF ATTACHED ADU: R 275.54 SF TOTAL FLOOR AREA 2,974.29 SF A - GARAGE FLOOR AREA 422.81 SFRESPONSES TO PLAN CHECK COMMENTSLL103/26/20191 1 N True North Project North 1 808080805036DC 3080 4040SC 11580 5080 2056FX 2056FX 30802820AW28805080150802880 41050TC3680 28802 8 7 0 F X 2870FX 2870F X 2880 210802880 41050TC 1630FX 2 A4.1 2 A4.1 1 A4.1 1 A4.1 2.A 2.B 2.C 2.D 37'-4 1/4"5'-1"5'-8"8'-2"20'-0"12'-3 1/2" 8'-1 1/2" 4'-0 1/2"4'-1 1/2"4'-0 1/2"15'-0"12'-0"7'-9" 20'-0"15'-0"14'-0"6'-7"18'-0"16'-2" ATTACHED ADU19'-7 3/4" ATTACHED ADU7'-5 1/2"14'-11"13'-7" 5'-0"21'-0"HALL PANTRYFAMILY DINING ISLAND BATH ENTRY KITCHEN GARAGE OFFICE UTILITY F.C. +10'0" F.C. +10'0" F.C. +11'3" F.C. +10'0" F.C. +10'0" F.C. +10'0" F.F. +0'0" F.F. +0'0" F.F. +0'0" F.F. +0'0" 1 2 DN 12 DN F.F. -1'3"BALCONY ABOVEF.P. 20' MINUTE FIRE RATED DOOR W/ SELF CLOSING & SELF LATCHING MECHANISMS. CLOSET DECK BEDROOM1DN2 BATH CLOSET F.P. OUTLINE FLOOR ABOVE. OUTLINE FLOOR ABOVE. OPEN ABOVE OPEN ABOVE 1 2 DN F.F. +0'0" (N) ELEC. METER. 300 AMP. (N) GAS METER. (under a separate permit)(under a separate permit)PROPOSED FIRST FLOORPLANSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A2.1DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.LEGEND: EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED NEW INTERIOR CONSTRUCTION; 2x4 WD. STUD, 1/2" GYP. BD. EACH SIDE NEW EXTERIOR CONSTRUCTION. NEW 1-HR FIRE RATED WALL; 2x4 WD. STUD, 5/8" TYPE "X" GYP. BD. EACH SIDE. SEE PLAN FOR LOCATIONS.1 Scale: 1/4"=1'-0" PROPOSED FIRST FLOOR PLAN GREEN BUILDING: FINISHES: A.USE LOW-VOC INTERIOR WALL/CEILING PAINTS (<50 GRAMS PER LETTER (GPL) VOCS REGARDLESS OF SHEEN) CGBSC 4.504.2.2 B.USE LOW-VOC COATINGS THAT MEET SCAQMD RULE 1113 (CGBSC 4.504.2.3) PLUMBING: ALL EXISTING NON-COMPLIANT PLUMBING FIXTURES SHALL BE UPGRADED: A.WATER CLOSETS WITH A FLOW RATE IN EXCESS OF 1.6 GPF WILL NEED TO BE REPLACED WITH WATER CLOSETS WITH A MAXIMUM FLOW RATE OF 1.28 GPF. B.SHOWER HEADS WITH A FLOW RATE GREATER THAN 2.5 GPM WILL NEED TO BE REPLACED WITH A MAXIMUM 2.0 GPM SHOWER HEAD. C.LAVATORY AND KITCHEN FAUCETS WITH A FLOW RATE GREATER THAN 2.2 GPM WILL NEED TO BE REPLACED WITH A FAUCET WITH MAXIMUM FLOW RATE OF 1.2 GPM (OR 1.8 GPM FOR KITCHEN FAUCETS). X LINEAL FEET OF EAVE W/2X RAFTERS @ 16" O.C.: X'/16" = ±X AVAILABLE BLOCKS NEW UNDER FLOOR AREA TO BE VENTED = XXX SQ.FT. NEW ATTIC AREA TO BE VENTED = XXX SQ.FT. XXX/150(144) = XXX SQ.IN. NFVA REQUIREDXXX/150(144) = XXX SQ.IN. NFVA REQUIRED 1 FLOOR VENT UNIT: 13.5" X 7.5" = 101.25 SQ.IN NFVA 1 EAVE BLOCKING VENT UNIT: 14" x 5.5" = 77 SQ.IN NFVA X FLOOR VENTS PROVIDED, DISTRIBUTED EVENLY: (X) x XXX SQ.IN = XXX SQ.IN. NFVA XXX SQ.IN. NFVA PROVIDED > XXX SQ.IN. NFVA REQUIRED X EAVE VENTS PROVIDED, DISTRIBUTED EVENLY: (X) x X SQ.IN. = XXX SQ.IN. NFVA XXX SQ.IN. NFVA PROVIDED > XXX SQ.IN. NFVA REQUIRED LEGEND: EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED NEW INTERIOR CONSTRUCTION; 2x4 WD. STUD, 1/2" GYP. BD. EACH SIDE NEW EXTERIOR CONSTRUCTION; SEE 5/A3.2 NEW 1-HR FIRE RATED WALL; 2x4 WD. STUD, 5/8" TYPE "X" GYP. BD. EACH SIDE. SEE PLAN FOR LOCATIONS. LEGEND: EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED LEGEND: EXISTING CONSTRUCTION NEW CONSTRUCTION TYPICAL NOTES: updated 10/12/18 Calgreen changes ELECTRICAL LEGEND (ALL LIGHTING TO BE HIGH EFFICACY) LAUNDRY/BATHROOM VENTILATION: FOR LAUNDRY ROOMS AND BATHROOMS WITHOUT AN OPERABLE WINDOW: A.PROVIDE MECHANICAL VENTILATION SYSTEM CAPABLE OF 5 AIR CHANGES/HR. TO EXTERIOR. B.USE SMOOTH METAL DUCT FOR DRYER EXHAUST WITH A MAX. LENGTH OF 14', TO OUTSIDE WITH BACKDRAFT DAMPER AND TWO 90° ELBOWS AND A MIN. OF 4" DIA. C.TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS SHALL BE A MINIMUM OF 3 FEET FROM PROPERTY LINES OR ANY OPENINGS INTO THE BUILDING (i.e., DRYERS, BATH AND UTILITY FANS, ETC., MUST BE 3 FEET AWAY FROM DOORS WINDOWS, OPENING SKYLIGHTS OR ATTIC VENTS). D.EXHAUST FANS SHALL HAVE A MIN. OF 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION AND BE ENERGYSTAR COMPLIANT AND BE EQUIPPED WITH A HUMIDISTAT AND HUMIDITY CONTROL. AND BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM. PLUMBING: A.ALL NEW TOILETS SHALL HAVE AN EFFECTIVE FLUSH VOLUME NOT TO EXCEED 1.28 GALLONS PER FLUSH. B.ALL NEW LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.2 GALLONS PER MINUTE AT 60 PSI. C.ALL NEW SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 80 PSI. D.ALL NEW KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE AT 60 PSI AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN ELECTRICAL: A.ALL BRANCH CIRCUITS TO BE PROTECTED BY ARC-FAULT CIRCUIT INTERRUPTER(AFCI). B.PROVIDE AFCI AND GFCI PROTECTION AT ALL RECEPTACLES SERVING KITCHEN COUNTERTOPS. C.AT EACH KITCHEN AND DINING AREA COUNTER SPACE WIDER THAN 12", LOCATE A RECEPTACLE SO THAT NO POINT ALONG THE COUNTER WALL IS OVER 24" FROM A RECEPTACLE. COUNTERTOP RECEPTACLES REQUIRED WITHIN 24" EACH SIDE OF A BREAK IN THE CONTINUOUS COUNTERTOP SURFACE (SINKS-STOVES). D.REQ'D RECEPTACLES MOUNTED ON THE SIDES OF CABINETS SHALL BE A MAXIMUM OF 12" BELOW THE COUNTERTOP SURFACE WITH A MAXIMUM OF 6" COUNTERTOP OVERHANG. E.PROVIDE AT LEAST TWO (2) 20 AMP CIRCUITS FOR COUNTER RECEPTACLES. SMOKE DETECTORS: A.SMOKE DETECTOR SYSTEM SHALL BE HARD WIRED, INTERCONNECTED TO SOUND SIMULTANEOUSLY AND EQUIPPED WITH BATTERY BACKUP. B.INSTALL DETECTORS IN EACH BEDROOM, AT EACH CORRIDOR/AREA NEXT TO THE BEDROOM, AT THE TOP OF STAIRS AND EACH STORY AND BASEMENT. C.MULTIPLE SMOKE DETECTORS ARE REQUIRED WHEN CEILING LEVELS/ ELEVATIONS CHANGE OR ARE INTERRUPTED BY ARCHITECTURAL ELEMENTS (CASED OPENINGS, ARCHWAYS, SKYLIGHT WELLS, ETC.) . D.SMOKE DETECTORS SHALL BE LISTED AND COMPLY WITH UL 217 AND BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH NFPA 720 AND MANUFACTURERS INSTRUCTIONS. BATHROOM: A.WATER CLOSETS SHALL BE LOCATED IN SPACES NOT LESS THAN 30" IN WIDTH AND 24" IN FRONT. B.WATER RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT EXPOSURE TO WATER. CRC 702.3.7.1 C.BACKER FOR SHOWER AND TUB SHOWER WALLS TO BE FIBER-CEMENT, FIBER REINFORCED CEMENTITIOUS BACKER UNITS, GLASS MAT GYPSUM BACKERS OR FIBER-REINFORCED GYPSUM BACKERS TO A MIN HEIGHT OF 72" ABOVE THE FLOOR. D.USE 2X8 WOODEN BACKING IN ALL BATHROOM WALLS AT WATER CLOSET SHOWER AND BATHTUB, LOCATED AT 34" FROM FLOOR TO CENTER OF THE BACKING SUITABLE FOR THE ADDITION OF GRAB BARS. E.DOORS AND PANELS OF TUB AND SHOWER ENCLOSURES SHALL BE FULLY TEMPERED LAMINATED SAFETY GLASS OR APPROVED PLASTIC. F.SHOWER COMPARTMENTS SHALL HAVE MIN INTERIOR FLOOR AREA OF 1024 SQ IN AND ABLE TO CONTAIN A 30" DIA. CIRCLE. G.SHOWER AND TUB SHOWER COMBINATION IN ALL BUILDING SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE. CARBON MONOXIDE ALARMS: CARBON MONOXIDE ALARMS REQUIRED BY SECTION 420.6.2 SHALL BE INSTALLED AND MAINTAINED IN THE FOLLOWING LOCATIONS: A.OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM (S). B.ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. C.IN GROUP R-1 OCCUPANCIES; ON THE CEILING OF EVERY SLEEPING UNIT OR OTHER LOCATIONS WITHIN THE SLEEPING UNIT IN COMPLIANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. D.CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH BATTERY BACK-UP. ALARM WIRING SHALL BE DIRECTLY CONNECTED TO THE PERMANENT BUILDING WIRING WITHOUT A DISCONNECTING SWITCH OTHER THAN AS REQUIRED FOR OVERCURRENT PROTECTION. E.WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT, THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. F.CARBON MONOXIDE ALARMS SHALL BE LISTED AND COMPLY WITH UL 2034 AND BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH NFPA 720 AND MANUFACTURERS INSTRUCTIONS. BATHROOM ELECTRICAL: A.PROVIDE 20AMP DEDICATED BRANCH CIRCUIT TO SUPPLY THE BATHROOM OUTLETS. THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. (EXCEPTION-WHERE THE CIRCUIT SUPPLIES A SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENT WITHIN THE SAME BATHROOM SHALL BE PERMITTED TO BE SUPPLIED). B.ALL BRANCH CIRCUITS TO BE PROTECTED BY GROUND FAULT CIRCUIT INTERRUPTER (GFCI). KITCHEN VENTILATION: WHERE COMBUSTION APPLIANCES OR SOLID-FUEL BURNING APPLIANCES ARE LOCATED INSIDE THE PRESSURE BOUNDARY, THE MAXIMUM ALLOWABLE NET EXHAUST FLOW OF THE TWO LARGEST EXHAUST FANS SHALL NOT EXCEED 15 CFM PER 100 SQ. FT. OF OCCUPIABLE SPACE, WHEN OPERATING AT FULL CAPACITY. IF THE DESIGNED TOTAL NET FLOW EXCEEDS THIS LIMIT, THE NET EXHAUST FLOW MUST BE REDUCED BY REDUCING THE EXHAUST FLOW OR PROVIDING COMPENSATING OUT-DOOR AIRFLOW (NOTE: IF MAKE-UP AIR FAN IS INSTALLED IT MUST BE ELECTRICALLY INTERLOCKED WITH THE LARGEST EXHAUST FAN)LAUNDRY ELECTRICAL: A ALL BRANCH CIRCUITS TO BE PROTECTED BY ARC-FAULT (AFCI) CIRCUIT INTERRUPTER AND GROUND FAULT (GFCI) CIRCUIT INTERRUPTER. B PROVIDE 20AMP DEDICATED BRANCH CIRCUIT TO SUPPLY THE LAUNDRY RECEPTACLE OUTLET. C MINIMUM 30 AMP DEDICATED CIRCUIT FOR DRYER PER CEC 220.54. HIGH EFFICACY LIGHTING: A.ALL LIGHTING SHALL BE HIGH EFFICACY AS DEFINED BY CEC TABLE 150.0-A B.ALL PERMANENTLY INSTALLED SCREW-BASED LIGHT FIXTURES SHALL CONTAIN SCREW-BASED JA8 (JOINT APPENDIX 8) COMPLIANT LAMPS AND BE MARKED AS JA8-2016 OR JA8-2016-E. CEC 150.0(k)G C.ALL JA8 COMPLIANT LIGHT FIXTURES INSTALLED IN CEILING RECESSED DOWNLIGHTS, LED LUMINARIES WITH INTEGRAL SOURCES, PIN-BASED LED LAMPS, AND GU24 BASED LED LIGHT SOURCES SHALL BE CONTROLLED BY VACANCY SENSORS OR DIMMERS. D.AT LEAST ONE FIXTURE IN EACH BATRHROOM, GARAGE, LAUNDRY ROOM, AND UTILITY ROOM SHALL BE CONTROLLED BY A VACANCY SENSOR. E.ALL LIGHTING SHALL BE SWITCHED SEPARATELY FROM EXHAUST FANS (EXCEPT FOR KITCHEN EXHAUST HOODS). F.ALL UNDER CABINET LIGHTING SHALL BE SWITCHED SEPARATELY FROM OTHER LIGHTING SYSTEMS. G.GARAGE, LAUNDRY, AND UTILITY ROOMS: LIGHTING INSTALLED IN GARAGES, LAUNDRY, AND UTILITY ROOMS SHALL BE HIGH EFFICACY AND CONTROLLED BY VACANCY SENSORS. H.HIGH EFFICACY LIGHTING IS NOT REQUIRED IN CLOSETS OF LESS THAN 70 SF. I.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING SHALL BE HIGH EFFICACY AND CONTROLLED WITH A MANUAL ON/OFF SWITCH AND BY PHOTO CONTROL AND A MOTION SENSOR. PER ENERGY 110.9. J.ALL OTHER ROOMS: LIGHTING INSTALLED IN ALL OTHER ROOMS SHALL BE HIGH EFFICACY OR SHALL BE CONTROLLED BY EITHER DIMMERS AND VACANCY SENSORS. ATTIC/UNDERFLOOR INSTALLED FAU: A.UNIT SHALL BE ACCESSIBLE THROUGH AN OPENING AND PASSAGEWAY NOT LESS THAN THE LARGEST COMPONENT OF THE UNIT AND NOT LESS THAN 22"x30" B.THE DISTANCE FROM THE PASSAGEWAY ACCESS TO THE UNIT SHALL NOT EXCEED 20' C.THE WIDTH OF THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE SOLID FLOORING NOT LESS THAN 24" WIDE FROM THE ENTRANCE OPENING TO THE UNIT. D.A LEVEL WORKING PLATFORM NOT LESS THAN 30" BY 30" SHALL BE PROVIDED IN FRONT OF THE SERVICE SIDE OF THE UNIT. E.A PERMANENT 120V RECEPTACLE OUTLET AND A LIGHTING FIXTURE SHALL BE INSTALLED NEAR THE UNIT. THE SWITCH CONTROLLING THE LIGHTING FIXTURE SHALL BE LOCATED AT THE ENTRANCE TO THE PASSAGEWAY. ELECTRIC VEHICLE (EV) CHARGING: ELECTRIC VEHICLE SUPPLY EQUIPMENT SHALL BE INSTALLED TO FACILITATE THE FUTURE INSTALLATION OF AN EV CHARGING DEVICE AND MUST COMPLY WITH THE FOLLOWING: A.A LISTED TRADE SIZE 1 RACEWAY SHALL BE INSTALLED TO ACCOMMODATE A DEDICATED 208/240-VOLT BRANCH CIRCUIT. THE RACEWAY SHALL ORIGINATE FROM THE MAIN SERVICE PANEL OR SUB PANEL AND TERMINATES INTO A LISTED CABINET, BOX,OR OTHER ENCLOSURE IN CLOSE PROXIMITY TO THE FUTURE CHARGING DEVICE. B.THE SERVICE PANEL AND/OR SUB PANEL SHALL PROVIDE CAPACITY TO INSTALL A 40-AMP MIN. BRANCH CIRCUIT AND SPACE RESERVED TO ACCOMMODATE A BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE. C.THE ELECTRICAL PANEL SCHEDULE SHALL IDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE RESERVED FOR FUTURE EV CHARGING AS "EV CAPABLE". D.THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE". As shown TOWN STANDARDS: RESIDENTIAL ACCESSIBILITY A ALL PASSAGE DOOR SHALL BE AT LEAST 32 INCH DOORS ON THE ACCESSIBLE FLOOR LEVEL. B THE PRIMARY ENTRANCE DOOR SHALL BE A 36 INCH WIDE DOOR INCLUDING A 5'X5' LEVEL LANDING, MORE THAN 1 INCH OUT OF PLANE WITH THE IMMEDIATE INFERIOR FLOOR LEVEL AND WITH AN 18 INCH CLEARANCE AT INTERIOR STRIKE EDGE. C A DOOR BUZZER, BELL OR CHIME SHALL BE HARD WIRED AT PRIMARY ENTRANCE. FIREPLACE: A.NEW WOOD BURNING FIREPLACES SHALL BE AN EPA PHASE II APPROVED APPLIANCES OR GAS APPLIANCE PER TOWN ORDINANCE 1905. TREE LIMBS SHALL BE CUT WITHIN 10 FEET OF CHIMNEYS. 1 NOTES: A. GAS FIREPLACES INSTALLED IN THE TOWN OF LOS GATOS SHALL HAVE NO WOOD BURNING COMPONENTS. B. VENTILATION HEATING AND AIR CONDITIONING SYSTEMS SHALL HAVE MERV 6 FILTERS OR BETTER. C. A COMPLETED CF2R-LTG-01-E FORM SHALL BE PROVIDED TO THE TOWN BUILDING INSPECTOR PRIOR TO FINAL INSPECTION.RESPONSES TO PLAN CHECK COMMENTSLL103/26/20191 1 1 1 N True North Project North 1 EXHAUST FAN/EXHAUST FAN/LIGHT COMBO. SEE BATH ELECTRICAL NOTES, THIS PAGE. 'W' INDICATES CONTINUOUSLY OPERATING MULTI-SPEED WHOLE BUILDING VENTILATION FAN. SEE WHOLE BUILDING VENTILATION NOTES THIS PAGE. OUTDOOR LIGHT. EXTERIOR LIGHTING ATTACHED TO THE BUILDING SHALL BE HIGH EFFICACY WITH A MANUAL ON/OFF SWITCH AND CONTROLLED BY MOTION SENSOR & PHOTO CONTROL. FIXTURE SHALL BE DOWNWARD LIGHTING. RECEPTACLE. BRANCH CIRCUIT PROTECTED BY ARC-FAULT CIRCUIT INTERRUPTER. SEE ELECTRICAL NOTES THIS PAGE. ARC-FAULT CIRCUIT INTERRUPTER PROTECTED RECEPTACLE W/ GROUND FAULT CIRCUIT INTERRUPTER. SEE ELECTRICAL NOTES THIS PAGE. WATERPROOF RECEPTACLE W/ GROUND FAULT CIRCUIT INTERRUPTER. PROVIDE EXTERIOR GFCI WATERPROOF RECEPTACLES AT THE FRONT & REAR OF RESIDENCE WITHIN 6'- 6" OF GRADE. SURFACE MOUNT WALL SCONCE. VERIFY STYLE WITH HOMEOWNER PRIOR TO INSTALLATION. COMBINATION SMOKE DETECTOR AND CARBON MONOXIDE DETECTOR UNIT. SEE NOTES THIS PAGE CEILING OR FLOOR MOUNTED HVAC REGISTER. CHANDELIER VERIFY STYLE WITH HOMEOWNER PRIOR TO INSTALLATION. SURFACE MOUNT CEILING LIGHT FIXTURE OR PENDANT. VERIFY STYLE WITH HOMEOWNER PRIOR TO INSTALLATION. HIGH EFFICACY RECESSED LIGHT FIXTURE. SEE HIGH EFFICACY LIGHTING NOTES THIS PAGE. LIGHTS IN INSULATED CEILINGS SHALL BE IC RATED, HAVE ELECTRONIC BALLAST AND BE AIR- TIGHT (AT). UNDER-CABINET FLUORESCENT LIGHT. SHALL BE SWITCHED SEPARATELY FROM OTHER LIGHTING. 1 6 4 6 F X 1646F X1646FX 21070 8616TC 2870507028702870287028701626FX21702870287028703016FX 3016FX 5036FX 1626FX 1626FX 1626FX 5045TC4020DC5045TC1630FX 2870 2070FX2036FX2870 2870 2870 2870 50702 A4.1 2 A4.1 1 A4.1 1 A4.1 2.A 15'-1" 6'-0"12'-0"3'-0" 8'-6 1/2"7'-0"11'-10"5'-7 3/4"10'-2"6'-1 1/2"4'-0"20'-1"17'-8 1/2"12'-2"18'-0"3'-7"3'-6 1/2"11'-9 1/2"4'-6 1/4"17'-8 1/2"7'-5" 11'-5" 5'-0" 2'-0"6'-6"4'-0" 2'-0" 9'-6 1/2"2'-0"2'-0" 10'-0" BATH BEDROOM BATH BALCONY OPEN BELOW BEDROOM CLO. LAUNDRY HALL MASTER BDRM BATH OPEN BELOW BALCONY HALL F.C. +9'0" F.C. +9'0" F.C. +9'0" F.C. +9'0" F.C. +9'0" F.C. +9'0" F.C. +9'0" F.C. +9'0" F.C. +9'0" F.C. +9'0" F.C. +9'0" CLOSET CLO.NICHECLO. OUTLINE FLOOR BELOW. BALCONY REDUCTIONS. OUTLINE OLD BALCONY. CHANGED TO SINGLE DOOR.PROPOSED SECONDFLOOR PLANSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A2.2DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.1 Scale: 1/4"=1'-0" PROPOSED SECOND FLOOR PLAN LEGEND: EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED NEW INTERIOR CONSTRUCTION; 2x4 WD. STUD, 1/2" GYP. BD. EACH SIDE NEW EXTERIOR CONSTRUCTION. NEW 1-HR FIRE RATED WALL; 2x4 WD. STUD, 5/8" TYPE "X" GYP. BD. EACH SIDE. SEE PLAN FOR LOCATIONS. TYPICAL NOTES: LAUNDRY/BATHROOM VENTILATION: FOR LAUNDRY ROOMS AND BATHROOMS WITHOUT AN OPERABLE WINDOW: A.PROVIDE MECHANICAL VENTILATION SYSTEM CAPABLE OF 5 AIR CHANGES/HR. TO EXTERIOR. B.USE SMOOTH METAL DUCT FOR DRYER EXHAUST WITH A MAX. LENGTH OF 14', TO OUTSIDE WITH BACKDRAFT DAMPER AND TWO 90° ELBOWS AND A MIN. OF 4" DIA. C.TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS SHALL BE A MINIMUM OF 3 FEET FROM PROPERTY LINES OR ANY OPENINGS INTO THE BUILDING (i.e., DRYERS, BATH AND UTILITY FANS, ETC., MUST BE 3 FEET AWAY FROM DOORS WINDOWS, OPENING SKYLIGHTS OR ATTIC VENTS). D.EXHAUST FANS SHALL HAVE A MIN. OF 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION AND BE ENERGYSTAR COMPLIANT AND BE EQUIPPED WITH A HUMIDISTAT AND HUMIDITY CONTROL. AND BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM. PLUMBING: A.ALL NEW TOILETS SHALL HAVE AN EFFECTIVE FLUSH VOLUME NOT TO EXCEED 1.28 GALLONS PER FLUSH. B.ALL NEW LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.2 GALLONS PER MINUTE AT 60 PSI. C.ALL NEW SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 80 PSI. D.ALL NEW KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE AT 60 PSI AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN ELECTRICAL: A.ALL BRANCH CIRCUITS TO BE PROTECTED BY ARC-FAULT CIRCUIT INTERRUPTER(AFCI). B.PROVIDE AFCI AND GFCI PROTECTION AT ALL RECEPTACLES SERVING KITCHEN COUNTERTOPS. C.AT EACH KITCHEN AND DINING AREA COUNTER SPACE WIDER THAN 12", LOCATE A RECEPTACLE SO THAT NO POINT ALONG THE COUNTER WALL IS OVER 24" FROM A RECEPTACLE. COUNTERTOP RECEPTACLES REQUIRED WITHIN 24" EACH SIDE OF A BREAK IN THE CONTINUOUS COUNTERTOP SURFACE (SINKS-STOVES). D.REQ'D RECEPTACLES MOUNTED ON THE SIDES OF CABINETS SHALL BE A MAXIMUM OF 12" BELOW THE COUNTERTOP SURFACE WITH A MAXIMUM OF 6" COUNTERTOP OVERHANG. E.PROVIDE AT LEAST TWO (2) 20 AMP CIRCUITS FOR COUNTER RECEPTACLES. SMOKE DETECTORS: A.SMOKE DETECTOR SYSTEM SHALL BE HARD WIRED, INTERCONNECTED TO SOUND SIMULTANEOUSLY AND EQUIPPED WITH BATTERY BACKUP. B.INSTALL DETECTORS IN EACH BEDROOM, AT EACH CORRIDOR/AREA NEXT TO THE BEDROOM, AT THE TOP OF STAIRS AND EACH STORY AND BASEMENT. C.MULTIPLE SMOKE DETECTORS ARE REQUIRED WHEN CEILING LEVELS/ ELEVATIONS CHANGE OR ARE INTERRUPTED BY ARCHITECTURAL ELEMENTS (CASED OPENINGS, ARCHWAYS, SKYLIGHT WELLS, ETC.) . D.SMOKE DETECTORS SHALL BE LISTED AND COMPLY WITH UL 217 AND BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH NFPA 720 AND MANUFACTURERS INSTRUCTIONS. BATHROOM: A.WATER CLOSETS SHALL BE LOCATED IN SPACES NOT LESS THAN 30" IN WIDTH AND 24" IN FRONT. B.WATER RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT EXPOSURE TO WATER. CRC 702.3.7.1 C.BACKER FOR SHOWER AND TUB SHOWER WALLS TO BE FIBER-CEMENT, FIBER REINFORCED CEMENTITIOUS BACKER UNITS, GLASS MAT GYPSUM BACKERS OR FIBER-REINFORCED GYPSUM BACKERS TO A MIN HEIGHT OF 72" ABOVE THE FLOOR. D.USE 2X8 WOODEN BACKING IN ALL BATHROOM WALLS AT WATER CLOSET SHOWER AND BATHTUB, LOCATED AT 34" FROM FLOOR TO CENTER OF THE BACKING SUITABLE FOR THE ADDITION OF GRAB BARS. E.DOORS AND PANELS OF TUB AND SHOWER ENCLOSURES SHALL BE FULLY TEMPERED LAMINATED SAFETY GLASS OR APPROVED PLASTIC. F.SHOWER COMPARTMENTS SHALL HAVE MIN INTERIOR FLOOR AREA OF 1024 SQ IN AND ABLE TO CONTAIN A 30" DIA. CIRCLE. G.SHOWER AND TUB SHOWER COMBINATION IN ALL BUILDING SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE. CARBON MONOXIDE ALARMS: CARBON MONOXIDE ALARMS REQUIRED BY SECTION 420.6.2 SHALL BE INSTALLED AND MAINTAINED IN THE FOLLOWING LOCATIONS: A.OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM (S). B.ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. C.IN GROUP R-1 OCCUPANCIES; ON THE CEILING OF EVERY SLEEPING UNIT OR OTHER LOCATIONS WITHIN THE SLEEPING UNIT IN COMPLIANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. D.CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH BATTERY BACK-UP. ALARM WIRING SHALL BE DIRECTLY CONNECTED TO THE PERMANENT BUILDING WIRING WITHOUT A DISCONNECTING SWITCH OTHER THAN AS REQUIRED FOR OVERCURRENT PROTECTION. E.WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT, THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. F.CARBON MONOXIDE ALARMS SHALL BE LISTED AND COMPLY WITH UL 2034 AND BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH NFPA 720 AND MANUFACTURERS INSTRUCTIONS. BATHROOM ELECTRICAL: A.PROVIDE 20AMP DEDICATED BRANCH CIRCUIT TO SUPPLY THE BATHROOM OUTLETS. THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. (EXCEPTION-WHERE THE CIRCUIT SUPPLIES A SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENT WITHIN THE SAME BATHROOM SHALL BE PERMITTED TO BE SUPPLIED). B.ALL BRANCH CIRCUITS TO BE PROTECTED BY GROUND FAULT CIRCUIT INTERRUPTER (GFCI). KITCHEN VENTILATION: WHERE COMBUSTION APPLIANCES OR SOLID-FUEL BURNING APPLIANCES ARE LOCATED INSIDE THE PRESSURE BOUNDARY, THE MAXIMUM ALLOWABLE NET EXHAUST FLOW OF THE TWO LARGEST EXHAUST FANS SHALL NOT EXCEED 15 CFM PER 100 SQ. FT. OF OCCUPIABLE SPACE, WHEN OPERATING AT FULL CAPACITY. IF THE DESIGNED TOTAL NET FLOW EXCEEDS THIS LIMIT, THE NET EXHAUST FLOW MUST BE REDUCED BY REDUCING THE EXHAUST FLOW OR PROVIDING COMPENSATING OUT-DOOR AIRFLOW (NOTE: IF MAKE-UP AIR FAN IS INSTALLED IT MUST BE ELECTRICALLY INTERLOCKED WITH THE LARGEST EXHAUST FAN)LAUNDRY ELECTRICAL: A ALL BRANCH CIRCUITS TO BE PROTECTED BY ARC-FAULT (AFCI) CIRCUIT INTERRUPTER AND GROUND FAULT (GFCI) CIRCUIT INTERRUPTER. B PROVIDE 20AMP DEDICATED BRANCH CIRCUIT TO SUPPLY THE LAUNDRY RECEPTACLE OUTLET. C MINIMUM 30 AMP DEDICATED CIRCUIT FOR DRYER PER CEC 220.54. HIGH EFFICACY LIGHTING: A.ALL LIGHTING SHALL BE HIGH EFFICACY AS DEFINED BY CEC TABLE 150.0-A B.ALL PERMANENTLY INSTALLED SCREW-BASED LIGHT FIXTURES SHALL CONTAIN SCREW-BASED JA8 (JOINT APPENDIX 8) COMPLIANT LAMPS AND BE MARKED AS JA8-2016 OR JA8-2016-E. CEC 150.0(k)G C.ALL JA8 COMPLIANT LIGHT FIXTURES INSTALLED IN CEILING RECESSED DOWNLIGHTS, LED LUMINARIES WITH INTEGRAL SOURCES, PIN-BASED LED LAMPS, AND GU24 BASED LED LIGHT SOURCES SHALL BE CONTROLLED BY VACANCY SENSORS OR DIMMERS. D.AT LEAST ONE FIXTURE IN EACH BATRHROOM, GARAGE, LAUNDRY ROOM, AND UTILITY ROOM SHALL BE CONTROLLED BY A VACANCY SENSOR. E.ALL LIGHTING SHALL BE SWITCHED SEPARATELY FROM EXHAUST FANS (EXCEPT FOR KITCHEN EXHAUST HOODS). F.ALL UNDER CABINET LIGHTING SHALL BE SWITCHED SEPARATELY FROM OTHER LIGHTING SYSTEMS. G.GARAGE, LAUNDRY, AND UTILITY ROOMS: LIGHTING INSTALLED IN GARAGES, LAUNDRY, AND UTILITY ROOMS SHALL BE HIGH EFFICACY AND CONTROLLED BY VACANCY SENSORS. H.HIGH EFFICACY LIGHTING IS NOT REQUIRED IN CLOSETS OF LESS THAN 70 SF. I.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING SHALL BE HIGH EFFICACY AND CONTROLLED WITH A MANUAL ON/OFF SWITCH AND BY PHOTO CONTROL AND A MOTION SENSOR. PER ENERGY 110.9. J.ALL OTHER ROOMS: LIGHTING INSTALLED IN ALL OTHER ROOMS SHALL BE HIGH EFFICACY OR SHALL BE CONTROLLED BY EITHER DIMMERS OR VACANCY SENSORS. ATTIC/UNDERFLOOR INSTALLED FAU: A.UNIT SHALL BE ACCESSIBLE THROUGH AN OPENING AND PASSAGEWAY NOT LESS THAN THE LARGEST COMPONENT OF THE UNIT AND NOT LESS THAN 22"x30" B.THE DISTANCE FROM THE PASSAGEWAY ACCESS TO THE UNIT SHALL NOT EXCEED 20' C.THE WIDTH OF THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE SOLID FLOORING NOT LESS THAN 24" WIDE FROM THE ENTRANCE OPENING TO THE UNIT. D.A LEVEL WORKING PLATFORM NOT LESS THAN 30" BY 30" SHALL BE PROVIDED IN FRONT OF THE SERVICE SIDE OF THE UNIT. E.A PERMANENT 120V RECEPTACLE OUTLET AND A LIGHTING FIXTURE SHALL BE INSTALLED NEAR THE UNIT. THE SWITCH CONTROLLING THE LIGHTING FIXTURE SHALL BE LOCATED AT THE ENTRANCE TO THE PASSAGEWAY. ELECTRIC VEHICLE (EV) CHARGING: ELECTRIC VEHICLE SUPPLY EQUIPMENT SHALL BE INSTALLED TO FACILITATE THE FUTURE INSTALLATION OF AN EV CHARGING DEVICE AND MUST COMPLY WITH THE FOLLOWING: A.A LISTED TRADE SIZE 1 RACEWAY SHALL BE INSTALLED TO ACCOMMODATE A DEDICATED 208/240-VOLT BRANCH CIRCUIT. THE RACEWAY SHALL ORIGINATE FROM THE MAIN SERVICE PANEL OR SUB PANEL AND TERMINATES INTO A LISTED CABINET, BOX,OR OTHER ENCLOSURE IN CLOSE PROXIMITY TO THE FUTURE CHARGING DEVICE. B.THE SERVICE PANEL AND/OR SUB PANEL SHALL PROVIDE CAPACITY TO INSTALL A 40-AMP MIN. BRANCH CIRCUIT AND SPACE RESERVED TO ACCOMMODATE A BRANCH CIRCUIT OVERCURRENT PROTECTIVE DEVICE. C.THE ELECTRICAL PANEL SCHEDULE SHALL IDENTIFY THE OVERCURRENT PROTECTIVE DEVICE SPACE RESERVED FOR FUTURE EV CHARGING AS "EV CAPABLE". D.THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND VISIBLY MARKED AS "EV CAPABLE". As shown TOWN STANDARDS: RESIDENTIAL ACCESSIBILITY A ALL PASSAGE DOOR SHALL BE AT LEAST 32 INCH DOORS ON THE ACCESSIBLE FLOOR LEVEL. B THE PRIMARY ENTRANCE DOOR SHALL BE A 36 INCH WIDE DOOR INCLUDING A 5'X5' LEVEL LANDING, MORE THAN 1 INCH OUT OF PLANE WITH THE IMMEDIATE INFERIOR FLOOR LEVEL AND WITH AN 18 INCH CLEARANCE AT INTERIOR STRIKE EDGE. C A DOOR BUZZER, BELL OR CHIME SHALL BE HARD WIRED AT PRIMARY ENTRANCE. FIREPLACE: A.NEW WOOD BURNING FIREPLACES SHALL BE AN EPA PHASE II APPROVED APPLIANCES OR GAS APPLIANCE PER TOWN ORDINANCE 1905. TREE LIMBS SHALL BE CUT WITHIN 10 FEET OF CHIMNEYS. 1 RESPONSES TO PLAN CHECK COMMENTSLL103/26/20191 1 1 N True North Project North 1 2 2 10'-0"9'-0"28'-7" (MAX. BUILDING HEIGHT - 30-0"')8"(E) GRADE, TYP. FINISH FLOOR 358.5' FINISH CLG. 368.5' FINISH FLOOR 369.5' TOP PLATE 378.5' STUCCO WALLS EXTERIOR, TYP. BALCONY WITH IRON RAILINGS, TYP. CLASS 'A' SPANISH TILE ROOF SYSTEM, TYP. ROUND TOWER WITH CONICAL ROOF, TYP. DECORATIVE WOOD, TYP. SEE NOTE THIS PAGE. FRONT ARCHED DOOR, TYP. WOOD CORBELS, TYP. SQUARE COLUMNS, TYP. DECORATIVE CARRIAGE LIGHT. WEEP SCREED, TYP. STACK STONE. STUCCO BASE, TYP.10'-0"9'-0"28'-7" (MAX. BUILDING HEIGHT - 30-0"')8"1'-0"9'-0"(E) GRADE, TYP. FINISH FLOOR 358.5' FINISH CLG. 368.5' FINISH FLOOR 369.5' TOP PLATE 378.5' STUCCO WALLS EXTERIOR, TYP. BALCONY WITH IRON RAILINGS, TYP. CLASS 'A' SPANISH TILE ROOF SYSTEM, TYP. WOOD CORBELS, TYP. WEEP SCREED, TYP. STACK STONE. (N)ATTACHED ADU UNDER A SEPARED PERMIT. NEIGHBORS POOL HOUSE FENCE STUCCO BASE, TYP.PROPOSED EXTERIORELEVATIONSSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A3.1DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.1 Scale: 1/4"=1'-0" NORTH FRONT EXTERIOR ELEVATION 2 Scale: 1/4"=1'-0" SOUTH REAR EXTERIOR ELEVATION As shown NOTES: A.DECORATIVE WOOD. IGNITION-RESISTANT, FIRE-RETARDANT-TREATED WOOD PER SFM STANDARD 12-7A-5, ASTM E84. SEE DETAIL 7/A4.2 1 1 RESPONSES TO PLAN CHECK COMMENTSLL103/26/20191 1 1 1 1 1 2 2 2 RESPONSES TO PLAN CHECK COMMENTSLL207/09/2019 10'-0"9'-0"28'-7" (MAX. BUILDING HEIGHT - 30'-0")8"FINISH FLOOR 358.5' FINISH CLG. 368.5' FINISH FLOOR 369.5' TOP PLATE 378.5' (E) GRADE, TYP. STUCCO WALLS EXTERIOR, TYP. BALCONY WITH IRON RAILINGS, TYP. ROUND TOWER WITH CONICAL ROOF, TYP. DECORATIVE WOOD, TYP. SEE NOTE THIS PAGE. GROUPED ARCH WINDOWS, TYP. CLASS 'A' SPANISH TILE ROOF SYSTEM, TYP. (N)ATTACHED ADU UNDER A SEPARED PERMIT. WOOD CORBELS, TYP. SQUARE COLUMNS, TYP. WEEP SCREED, TYP. STACK STONE. STUCCO BASE, TYP.10'-0"9'-0"28'-7" (MAX. BUILDING HEIGHT - 30'-0")8"(E) GRADE, TYP. FINISH FLOOR 358.5' FINISH CLG. 368.5' TOP PLATE 378.5' FINISH FLOOR 369.5' STUCCO WALLS EXTERIOR, TYP. DECORATIVE WOOD, TYP. SEE NOTE THIS PAGE. CLASS 'A' SPANISH TILE ROOF SYSTEM, TYP. (N)ATTACHED ADU UNDER A SEPARED PERMIT. WOOD CORBELS, TYP. SQUARE COLUMNS, TYP. WEEP SCREED, TYP. STUCCO BASE, TYP. OBSCURED WINDOW.PROPOSED EXTERIORELEVATIONSSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A3.2DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.2 Scale: 1/4"=1'-0" WEST RIGHT EXTERIOR ELEVATION 1 Scale: 1/4"=1'-0" EAST LEFT EXTERIOR ELEVATION As shown NOTES: A.DECORATIVE WOOD. IGNITION-RESISTANT, FIRE-RETARDANT-TREATED WOOD PER SFM STANDARD 12-7A-5, ASTM E84. SEE DETAIL 7/A4.2 RESPONSES TO PLAN CHECK COMMENTSLL103/26/20191 1 1 1 1 1 1 2 2 2 RESPONSES TO PLAN CHECK COMMENTSLL207/09/2019 10'-0"9'-0"FINISH FLOOR +0'-0" FINISH CLG. +10'-0" TOP PLATE +20'-0" FINISH FLOOR +11'-0" 1 A4.1 10'-0"9'-0"FINISH FLOOR +0'-0" FINISH CLG. +10'-0" TOP PLATE +20'-0" FINISH FLOOR +11'-0" 2 A4.1 PROPOSED SECTIONSSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A4.1DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.2 Scale: 1/4"=1'-0" BUILDING SECTION 1 Scale: 1/4"=1'-0" BUILDING SECTION As shownRESPONSES TO PLAN CHECK COMMENTSLL103/26/2019 NEIGHBORHOODPHOTOGRAPHSSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A6.1DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.104 HILOW CT. 100 HILOW CT. 100 DEL CARLO CT. 16311 SHANNON RD. 16310 SHANNON RD. 16330 SHANNON RD.16344 SHADY VIEW LN. 16356 SHADY VIEW LN. 16347 SHADY VIEW LN. 16337 SHADY VIEW LN. PROJECT VICINITY MAP. As shown cLcL 61'-0"8'-0"1'-0"9:00 AM 6/21/20189:00 AM 12/21/2018PROPERTY LINE 142.27'PROPERTY 66.37'PROPERTY 118.52'PROPERTY 39.98'SHADY VIEW LN. (60' R.O.W.)SHANNON RD.(50' R.O.W.)(N) DRIVEWAY. EDGE PAVEMENT ROLLED CURB PROPERTY LINEEDGE PAVEMENTEDGE PAVEMENT ROLLED CURBPROPERTY LINE 78.01'PROPERTY LINE 78.01'SECOND FLOOR BUILDING OUTLINE FIRST FLOOR BUILDING OUTLINE (E)SWIMMING POOL (E)EXISTING NON- CONFORMING POOL HOUSE9' HEIGHT.2 1/2 : 12APPROXIMATE LOCATION OF (E) 1-STORY HOME AT 16344 SHADY VIEW LN. APPROXIMATE LOCATION OF (E) 2-STORY HOME AT 16330 SHANNON RD. (E) HOUSE cLcL 61'-0"8'-0"1'-0"12:00 PM 6/21/20181 2 :0 0 P M 1 2 /2 1 /2 0 1 8 PROPERTY LINE 142.27'PROPERTY 66.37'PROPERTY 118.52'PROPERTY 39.98'SHADY VIEW LN. (60' R.O.W.)SHANNON RD.(50' R.O.W.)(N) DRIVEWAY. EDGE PAVEMENT ROLLED CURB PROPERTY LINEEDGE PAVEMENTEDGE PAVEMENT ROLLED CURBPROPERTY LINE 78.01'PROPERTY LINE 78.01'SECOND FLOOR BUILDING OUTLINE FIRST FLOOR BUILDING OUTLINE (E)SWIMMING POOL (E)EXISTING NON- CONFORMING POOL HOUSE9' HEIGHT.2 1/2 : 12APPROXIMATE LOCATION OF (E) 1-STORY HOME AT 16344 SHADY VIEW LN. APPROXIMATE LOCATION OF (E) 2-STORY HOME AT 16330 SHANNON RD. (E) HOUSE cLcL 61'-0"8'-0"1'-0"3:0 0 P M 6/2 1/2 0 1 8 3:00 PM 12/21/2018 PROPERTY LINE 142.27'PROPERTY 66.37'PROPERTY 118.52'PROPERTY 39.98'SHADY VIEW LN. (60' R.O.W.)SHANNON RD.(50' R.O.W.)(N) DRIVEWAY. EDGE PAVEMENT ROLLED CURBEDGE PAVEMENTPROPERTY LINE 78.01'PROPERTY LINE 78.01'SECOND FLOOR BUILDING OUTLINE FIRST FLOOR BUILDING OUTLINE (E)SWIMMING POOL (E)EXISTING NON- CONFORMING POOL HOUSE9' HEIGHT.2 1/2 : 12APPROXIMATE LOCATION OF (E) 1-STORY HOME AT 16344 SHADY VIEW LN. APPROXIMATE LOCATION OF (E) 2-STORY HOME AT 16330 SHANNON RD. (E) HOUSE SHADOW STUDYSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A6.2DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.1 Scale: 1/16"=1'-0" PROPOSED FIRST FLOOR PLAN 2 Scale: 1/16"=1'-0" PROPOSED FIRST FLOOR PLAN 3 Scale: 1/16"=1'-0" PROPOSED FIRST FLOOR PLAN June 21st 9:00am December 21st 9:00am June 21st 12:00pm December 21st 12:00pm June 21st 3:00pm December 21st 3:00pm LEGEND: JUNE SHADOW DECEMBER SHADOW As shownRESPONSES TO PLAN CHECK COMMENTSLL103/26/2019N True North Project North 1 RESPONSES TO PLAN CHECK COMMENTSLL207/09/2019 26'-9 1/2"28'-11 1/2"25'-8 1/2"18'-3 1/2"15'-3 1/2"19'-11"15'-10 1/2"15'-5"29'-0"10'-0"9'-0"28'-7" (MAX. BUILDING HEIGHT - 30'-0")8"FINISH FLOOR 358.5' FINISH CLG. 368.5' FINISH FLOOR 369.5' TOP PLATE 378.5'SCHEMATICNEIGHBORHOODELEVATIONSSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:PLANNING SET 7/18/2019 LL / JW A6.3DESCRIPTIONDATE:PROJECT DESCRIPTION:Coulson Residence16336 Shady View LnLos Gatos, CA 95032BYDATENO.SHEET TITLE:DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-47845512/17/2018DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.As shown 104 HILOW CT.100 HILOW CT. 100 DEL CARLO CT. 16311 SHANNON RD. 16330 SHANNON RD. 16344 SHADY VIEW LN. 16356 SHADY VIEW LN.16347 SHADY VIEW LN. 16337 SHADY VIEW LN. 16336 SHADY VIEW LN.RESPONSES TO PLAN CHECK COMMENTSLL207/09/20192