Loading...
15358 Santella Ct - Staff Report Exh.12V I S O S O R E S I D E N C E 1 5 3 5 8 S A N T E L L A C O U R T L O S G A T O S, C A L I F O R N I A 9 5 0 3 2 11 OCTOBER 2 0 1 7 161114 11 OCTOBER 2017 B.6 EXHIBIT 12 DRAWING INDEX 1 APPLICABLE BUILDING CODES 18 2016 CALIFORNIA BUILDING CODE:PART 1 CALIFORNIA ADMINISTRATIVE CODEPART 2 CALIFORNIA BUILDING CODE, VOL. 1 & 2PART 2.5 CALIFORNIA RESIDENTIAL CODEPART 3 CALIFORNIA ELECTRICAL CODEPART 4 CALIFORNIA MECHANICAL CODEPART 5 CALIFORNIA PLUMBING CODEPART 6 CALIFORNIA ENERGY CODEPART 8 CALIFORNIA HISTORICAL BUILDING CODEPART 9 CALIFORNIA FIRE CODEPART 11 CALIFORNIA GREEN BUILDING STANDARDS CODE - CALGREEN, 1STSTATE-ADOPTED GREEN CODEPART 12 CALIFORNIA REFERENCED STANDARDS CODE 2016 CALIFORNIA RESIDENTIAL CODE:SECTION R337 CODE OF ORDINANCES 2009 LOS GATOS TOWN CODE SPECIAL INSPECTIONS SEE APPROVED BUILDING PERMIT SPECIAL PER CBC 1701.5 AND INSPECTIONS FORM AND STRUCTURAL THE BUILDING OFFICIAL DRAWINGS FOR ADDITIONAL INFORMATION DESIGN TEAM DIRECTORY 5 OWNER LUIS F VISOSO AND MARI CARMEN CALDERON DE VISOSO 6972 CHIALA LN. SAN JOSE, CA 95129 T: 408.605.6798 ATTN: LUIS F VISOSO LFVISOSOL@CISCO.COM ARCHITECT MARK HORTON / ARCHITECTURE 135 SOUTH PARK SAN FRANCISCO, CA 94107 T: 415.543.3347 F: 415.543.1440 ATTN: MARK HORTON MARKHORTON@MH-A.COM ATTN: JESSICA TANGEMAN JTANGEMAN@MH-A.COM DESIGN ARCHITECT DOS JAIME GUZMAN ARQUITECTOS MEXICO CITY, MEXICO T: 044.55.32.33.19.43 ATTN: JAIME GUZMAN INFO@DOSJAIMEGUZMANARQ.COM SURVEYOR HMH ENGINEERS 1570 OAKLAND ROAD SAN JOSE, CA 95131 T: 408.487.2200 F: 408.487.2222 ATTN: DAVID WILSON DWILSON@HMHCA.COM GEOTECHNICAL ENGINEER ROMIG ENGINEERS, INC. 1390 EL CAMINO REAL, 2ND FLOOR SAN CARLOS, CA 94070 T: 650.591.5224 F: 650.591.5251 ATTN: LUCAS OTTOBONI, P.E. T: 650.591.5224 x. 30 LUCAS@ROMIGENGINEERS.COM CIVIL ENGINEER LEA & BRAZE ENGINEERING, INC. SAN FRANCISCO & BAY AREA REGION 2495 INDUSTRIAL PARKWAY WEST HAYWARD, CA 94545 T: 510.887.4086 F: 510.887.3019 ATTN: TIM GOSWAMI T: 510.887.4086 x.132 TGOSWAMI@LEABRAZE.COM LANDSCAPE ARCHITECT KIKUCHI + KANKEL DESIGN GROUP 61 E. MAIN STREET, SUITE C LOS GATOS, CA 95030 T: 408.356.5980 ATTN: WARREN BARNES WBARNES@KKDESIGNGROUP.COM STRUCTURAL ENGINEER FTF ENGINEERING, INC. 1916 MCALLISTER ST. SAN FRANCISCO, CA 94115 T: 415.931.8460 F: 415.931.8461 ATTN: RANDY COLLINS T: 415.931.8460 x.101 RANDY@FTFENGINEERING.COM MECHANICAL ENGINEER MONTEREY ENERGY GROUP 26465 CARMEL RANCHO BLVD. #8 CARMEL, CA 93923 T: 831.372.8328 F: 831.359.4173 ATTN: DAVID KNIGHT T: 831.250.0314 DAVE@MEG4.COM LIGHTING DESIGN REVOLVER DESIGN 3082 BUENA VISTA WAY BERKELEY, CA 94708 T: 510.558.4080 ATTN: MICHAEL WEBB T: 510.501.1692 MICHAEL@REVOLVERDESIGN.COM SPECIFICATIONS ARCHITECTURAL SPECIFCATIONS SERVICES 443 GOLD MINE DRIVE SAN FRANCISCO, CA 94131 T: 415.920.2244 ATTN: JOHN A. RAEBER JOHNRAEBER@GMAIL.COM HOA COMMON INTEREST MANAGEMENT SERVICES 315 DIABLO ROAD SUITE 221 DANVILLE, CA 94526 T: 925.743.3080 ATTN: BETH RAMIREZ T: 408.370.9902 x.318 BRAMIREZ@COMMONINTEREST.COM VICINITY MAP 17 CONSTRUCTION TEAM DIRECTORY 9 GENERAL CONTRACTOR LENCIONI CONSTRUCTION COMPANY, INC. 420 MAPLE STREET REDWOOD CITY, CA 94063 T: 650.216.9900 F: 650.649.1757 ATTN: CHAD LENCIONI CHAD@LENCIONICONSTRUCTION.COM XXXXXXXXX XXXXXXXXXX ADDRESS CITY, STATE ZIP T: XXX.XXX.XXXX F: XXX.XXX.XXXX ATTN: NAME EMAIL XXXXXXXXX XXXXXXXXXX ADDRESS CITY, STATE ZIP T: XXX.XXX.XXXX F: XXX.XXX.XXXX ATTN: NAME EMAIL XXXXXXXXX XXXXXXXXXX ADDRESS CITY, STATE ZIP T: XXX.XXX.XXXX F: XXX.XXX.XXXX ATTN: NAME EMAIL XXXXXXXXX XXXXXXXXXX ADDRESS CITY, STATE ZIP T: XXX.XXX.XXXX F: XXX.XXX.XXXX ATTN: NAME EMAIL XXXXXXXXX XXXXXXXXXX ADDRESS CITY, STATE ZIP T: XXX.XXX.XXXX F: XXX.XXX.XXXX ATTN: NAME EMAIL XXXXXXXXX XXXXXXXXXX ADDRESS CITY, STATE ZIP T: XXX.XXX.XXXX F: XXX.XXX.XXXX ATTN: NAME EMAIL XXXXXXXXX XXXXXXXXXX ADDRESS CITY, STATE ZIP T: XXX.XXX.XXXX F: XXX.XXX.XXXX ATTN: NAME EMAIL XXXXXXXXX XXXXXXXXXX ADDRESS CITY, STATE ZIP T: XXX.XXX.XXXX F: XXX.XXX.XXXX ATTN: NAME EMAIL XXXXXXXXX XXXXXXXXXX ADDRESS CITY, STATE ZIP T: XXX.XXX.XXXX F: XXX.XXX.XXXX ATTN: NAME EMAIL EXISTING CONDITIONS PROPOSED PROJECT REQUIRED / PERMITTED ZONING DISTRICT HR-2 1/2:PD SAME - LAND USE SINGLE-FAMILY HOME SAME - GENERAL PLAN DESIGNATION HILLSIDE RESIDENTIAL SAME - LOT SIZE (S.F.) GROSS LOT AREA 114,858.7 114,858.7 40,000 SF MIN. NET LOT AREA -SAME - ACRES 2.6 SAME .92 MIN. EXTERIOR MATERIALS SIDING -STUCCO, NATURAL STONE, WOOD, CONCRETE -TRIM -ANOD. ALUM., PAINTED STEEL, G.S.M.- WINDOWS -ANOD. ALUM.- ROOFING -MODIFIED BITUMINOUS MEMBRANE ROOF - BUILIDNG FLOOR AREA LOWER LEVEL -1,090.4 SF 6,000 SF MAX.MAIN LEVEL -3,310.6 SFCELLAR-694.8 SF EXEMPT GARAGE / UTILITIES -876 SF 400 SF EXEMPTION TOTAL (EXCLUDING CELLAR)-5,277 SF 6,400 SF MAX. SETBACKS (FT.) FRONT -30'-0"30 FT. MIN. REAR -220'-11 1/2"25 FT. MIN. SIDE SOUTH -23'-6"20 FT. MIN. SIDE WEST -20'-7"20 FT. MIN. AVERAGE SLOPE (%)21.7%SAME -MAX. HT. (FT.)-25'-0"25 FT. MAX. BUILDING COVERAGE (%)-4.7%NO MAX. IMPERVIOUS COVERAGE (%)-1.5%NO MAX. PARKING GARAGE -680.2 SF - 3 SPACES - UNCOVERED SPACES -1,238.3 SF - 3 SPACES - SEWER OR SEPTIC -SEWER - PROJECT DATA TABLE 19 DEFERRED PERMITS 14 THE FOLLOWING PERMITS WILL BE SUBMITTED FOR APPROVAL SEPARATELY FROM THE PRIMARY BUILDING PERMIT: FIRE SPRINKLER PHOTOVOLTAIC SYSTEM IRRIGATION SYSTEM SITE RETAINING WALLS GRADING PERMIT EXISTING CONDITIONS PROPOSED PROJECT REQUIRED / PERMITTED STREET ADDRESS 15358 SANTELLA COURT, LOS GATOS, CA 95032 SAME - ASSESSOR'S PARCEL NUMBER 527 09 037 SAME - LOT NO.LOT 10 / THE HIGHLANDS SAME - FIRE ZONE --- CONSTRUCTION TYPE TYPE V-NR / SPRINKLERED - V-B SAME - OCCUPANCY TYPE R3 - SINGLE FAMILY DWELLING / TWO STORIES SAME - PROJECT INFORMATION 20 SHEET DRAWING TITLE ARCHITECTURAL A0.1 COVER SHEET X X X X X X X A0.2 TITLE SHEET X X X X X X X A0.3 CLEAN BAY X X X A0.4 GENERAL NOTES & FIRE DEPT.X X X X A0.5 CAL GREEN X X X X A0.6 CAL GREEN X X X X A0.7 MATERIALS X X X X X X A0.8 CONSTRUCTION MANAGEMENT PLAN X X X X A0.9 CELLAR / BASEMENT DIAGRAM X X X X A1.1 SITE PLAN X X X X X X X A1.2 SITE PLAN X X X X X X X A2.1 LOWER LEVEL X X X X X X A2.2 MAIN LEVEL X X X X X X A2.3 ROOF PLAN X X X X X X A2.4 ENLARGED FLOOR PLANS X A2.5 ENLARGED FLOOR PLANS X A2.6 RCP X A2.7 RCP X A2.8 ELECTRICAL X A2.9 ELECTRICAL X A3.1 EXTERIOR ELEVATIONS X X X X X X A3.2 EXTERIOR ELEVATIONS X X X X X X A3.3 BUILDING SECTIONS X X X X X X A3.4 BUILDING SECTIONS X X X X X X A3.5 BUILDING SECTIONS X X X X X X X A3.6 BUILDING SECTIONS X X X X X X A3.7 BUILDING SECTIONS X X X X X X A4.1 INTERIOR ELEVATIONS X A4.2 INTERIOR ELEVATIONS X A4.3 INTERIOR ELEVATIONS X X X X A4.4 INTERIOR ELEVATIONS X A4.5 INTERIOR ELEVATIONS X A4.6 INTERIOR ELEVATIONS X A4.7 INTERIOR ELEVATIONS X A4.8 INTERIOR ELEVATIONS X A4.9 INTERIOR ELEVATIONS X A4.10 INTERIOR ELEVATIONS X A4.11 INTERIOR ELEVATIONS X A4.12 INTERIOR ELEVATIONS X A4.13 INTERIOR ELEVATIONS X A4.14 INTERIOR ELEVATIONS X A5.1 WALL TYPES: CONCRETE X A5.2 WALL TYPES: CONCRETE X A5.3 WALL TYPES: INTERIOR X A5.4 WALL TYPES: INTERIOR X A5.5 WALL TYPES: INTERIOR X A5.6 WALL TYPES: INTERIOR X A5.7 WALL TYPES: INTERIOR X A5.8 WALL TYPES: EXTERIOR X A5.9 WALL TYPES: EXTERIOR X A5.10 WALL TYPES: FLOOR X A5.11 WALL TYPES: CEILING X A5.12 RAILING TYPES A5.13 RAILING TYPES A5.14 DETAILS A5.15 DETAILS A5.16 DETAILS A5.17 DETAILS A5.18 DETAILS A5.19 DETAILS A5.20 DETAILS A6.1 ENLARGED STAIR PLANS X A6.2 ENLARGED PLANS X A7.1 DOOR SCHEDULES X X X A7.2 WINDOW SCHEDULES X X X A7.3 INTERIOR FINISH SCHEDULES X A7.4 EXTERIOR FINISH SCHEDULES X X X A7.5 SCHEDULES X A7.6 ELECTRICAL SCHEDULES SURVEY 1 (HMH)LANDS OF VISOSO BASE X X X X CIVIL C-1.0 TITLE SHEET X X X X X X C-1.1 EXTENDED SITE PLAN X X X X X X C-1.2 OVERALL PROPERTY SITE PLAN X X X X X C-2.0 PRELIMINARY GRADING & DRAINAGE PLAN X X X X X X X C-3.0 PRELIMINARY UTILITY PLAN X X X X X X X C-3.1 PRELIMINARY UTILITY PLAN X X X X C-4.0 GRADING SPECIFICATIONS X X X X X X C-5.0 DETAILS X X X X X X C-5.1 DETAILS X X X X X X ER-1 PRELIMINARY EROSION CONTROL PLAN X X X X X X ER-2 EROSION CONTROL DETAILS X X X X X X SW-1 STORM WATER POLLUTION PREVENTION PLAN X X X X X X LANDSCAPE L1.0 PLANTING PLAN X X X STRUCTURAL S-2.0 LOWER LEVEL FOUNDATION PLAN X X X S-2.1 MAIN LEVEL FOUNDTATION PLAN & FRAMING PLAN X X X S-2.2 ROOF FRAMING PLAN X X X MECHANICAL M0.1 NOTES X X X M0.2 NOTES X X X M2.1 MAIN LEVEL RADIANT HEATING PLAN X X X M2.2 LOWER LEVEL RADIANT HEATING PLAN X X X M2.3 LOWER LEVEL VENTILATION PLAN X X X M2.4 MAIN FLOOR VENTILATION PLAN X X X M6.1 PIPING SCHEMATIC X X X M6.2 CONTROLS SCHEMATIC X X X M6.3 PIPING SCHEMATIC X X X M6.4 DETAILS X X X M6.5 HEATING SOURCE VENTING X X X SOLAR PV2.1 SOLAR PHOTOVOLTAIC ROOF LAYOUT & NOTES X X X DATEDATE28 FEB 1715 MAR 1724 MAY 1707 JUL 1703 AUG 1714 SEP 1711 OCT 17TITLETITLEA : DD PRICING SETB : PLANNING DEV. APP.B.2 : PLANNING DEV. APP.B.3 : PLANNING DEV. APP.B.4 : PLANNING DEV. APP.B.5 : PLANNING DEV. APP.B.6 : PLANNING DEV. APP.FIRE SAFETY DURING CONSTRUCTION 15 THE CONSTRUCTION SITE MUST COMPLY WITH APPLICABLE PROVISIONS OF THE CFC CHAPTER 33, AND THE SANTA CLARA COUNTY FIRE DEPARTMENT STANDARD DETAIL AND SPECIFICATION SI-7. 16114 A0.2 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 TITLE SHEET Materials storage & spill cleanup Non-hazardous materials management 4 Sand, dirt, and similar materials must be stored at least 10 feet from catch basins, and covered with a tarp during wet weather or when rain is forecast. 4 Use (but don’t overuse) reclaimed water for dust control as needed. 4 Sweep streets and other paved areas daily. Do not wash down streets or work areas with water! 4 Recycle all asphalt, concrete, and aggregate base material from demolition activities. 4 Check dumpsters regularly for leaks and to make sure they don’t overflow. Repair or replace leaking dumpsters promptly. Hazardous materials management 4 Label all hazardous materials and hazardous wastes (such as pesticides, paints, thinners, solvents, fuel, oil, and antifreeze) in accordance with city, state, and federal regulations. 4 Store hazardous materials and wastes in secondary containment and cover them during wet weather. 4 Follow manufacturer’s application instructions for hazardous materials and be careful not to use more than necessary. Do not apply chemicals outdoors when rain is forecast within 24 hours. 4 Be sure to arrange for appropriate disposal of all hazardous wastes. Spill prevention and control 4 Keep a stockpile of spill cleanup materials (rags, absorbents, etc. ) available at the construction site at all times. 4 When spills or leaks occur, contain them immediately and be particularly care- ful to prevent leaks and spills from reaching the gutter, street, or storm drain. Never wash spilled material into a gutter, street, storm drain, or creek! 4 Report any hazardous materials spills immediately! Dial 911 or your local emer- gency response number. Vehicle and equipment maintenance & cleaning 4 Inspect vehicles and equipment for leaks frequently. Use drip pans to catch leaks until repairs are made; repair leaks promptly. 4 Fuel and maintain vehicles on site only in a bermed area or over a drip pan that is big enough to prevent runoff. 4 If you must clean vehicles or equipment on site, clean with water only in a bermed area that will not allow rinsewater to run into gutters, streets, storm drains, or creeks. 4 Do not clean vehicles or equipment on-site using soaps, solvents, degreasers, steam cleaning equipment, etc. Dewatering operations 4 Reuse water for dust control, irrigation, or another on-site purpose to the greatest extent possible. 4 Be sure to call your city’s storm drain inspector before discharging water to a street, gutter, or storm drain. Filtration or diversion through a basin, tank, or sediment trap may be required. 4 In areas of known contamination, testing is required prior to reuse or discharge of groundwater. Consult with the city inspector to determine what testing to do and to interpret results. Contaminated groundwater must be treated or hauled off-site for proper disposal. Concrete, grout, and mortar storage & waste disposal 4 Be sure to store concrete, grout, and mortar under cover and away from drainage areas. These materials must never reach a storm drain. 4 Wash out concrete equipment/trucks off-site or designate an on-site area for washing where water will flow onto dirt or into a temporary pit in a dirt area. Let the water seep into the soil and dispose of hardened concrete with trash. Make sure your crews and subs do the job right! Storm drain polluters may be liable for fines of up to $10,000 per day! Runoff from streets and other paved areas is a major source of pollution in San Francisco Bay. Construction activities can directly affect the health of the Bay unless contractors and crews plan ahead to keep dirt, debris, and other construction waste away from storm drains and local creeks. Following these guidelines will ensure your compliance with local ordinance requirements. 4 Divert water from washing exposed aggregate concrete to a dirt area where it will not run into a gutter, street, or storm drain. 4 If a suitable dirt area is not available, collect the wash water and remove it for appropriate disposal off site. Earthwork & contaminated soils 4 Keep excavated soil on the site where it is least likely to collect in the street. Transfer to dump trucks should take place on the site, not in the street. 4 Use hay bales, silt fences, or other control measures to minimize the flow of silt off the site. Paving/asphalt work Saw cutting 4 Always completely cover or barricade storm drain inlets when saw cutting. Use filter fabric, hay bales, sand bags, or fine gravel dams to keep slurry out of the storm drain system. 4 Shovel, absorb, or vacuum saw-cut slurry and pick up all waste as soon as you are finished in one location or at the end of each work day (whichever is sooner!). 4 If saw cut slurry enters a catch basin, clean it up immediately. 4 Do not pave during wet weather or when rain is forecast. 4 Always cover storm drain inlets and man- holes when paving or applying seal coat, tack coat, slurry seal, or fog seal. 4 Place drip pans or absorbent material un- der paving equipment when not in use. 4 Protect gutters, ditches, and drainage courses with hay bales, sand bags, or earthen berms. 4 Do not sweep or wash down excess sand from sand sealing into gutters, storm drains, or creeks. Collect sand and return it to the stockpile, or dispose of it as trash. 4 Do not use water to wash down fresh asphalt concrete pavement. Painting 4 Never rinse paint brushes or materials in a gutter or street! 4 Paint out excess water-based paint before rinsing brushes, rollers, or containers in a sink. If you can’t use a sink, direct wash water to a dirt area and spade it in. 4 Paint out excess oil-based paint before cleaning brushes in thinner. 4 Filter paint thinners and solvents for reuse whenever possible. Dispose of oil-based paint sludge and unusable thinner as hazardous waste. 4 Avoid scheduling earth moving activities during the rainy season if possible. If grading activities during wet weather are allowed in your permit, be sure to implement all control measures necessary to prevent erosion. 4 Mature vegetation is the best form of erosion control. Minimize disturbance to existing vegetation whenever possible. 4 If you disturb a slope during construction, prevent erosion by securing the soil with erosion control fabric, or seed with fast- growing grasses as soon as possible. Place hay bales down-slope until soil is secure. 4 If you suspect contamination (from site history, discoloration, odor, texture, abandoned underground tanks or pipes, or buried debris), call your local fire department for help in determining what testing should be done. 4 Manage disposal of contaminated soil according to Fire Department instructions. Bay Area Stormwater Management Agencies Association (BASMAA) 1-888-BAYWISE Pollution Prevention —It’s Part of the Plan 16114 A0.3 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 CLEAN BAY GENERAL NOTES 5 GENERAL NOTES & CONDITIONS C O N T R A C T GENERAL CONDITIONS: AIA Document A201, General Conditions for the Performance of the Contract, is hereby incorporated into these drawings and shall be considered as part of the requirements for the work. EXISTING CONDITIONS: Conditions shown on the drawings are as shown on the original drawings or as observed on the site, but their accuracy is not guaranteed. Contractor shall verify all dimensions and conditions at the site. All discrepancies shall be reported to architect prior to proceeding with the work. THE CONSTRUCTION DOCUMENTS: are provided to illustrate the design and general type of construction desired and imply the finest quality of construction, material and workmanship throughout. PERMITS: The contractor shall obtain and pay for all fees and permits relating to the project except for the General building Permit Plan Check Fee, which is the responsibility of the Owner. EXAMINATION OF THE SITE and portions thereof which will affect this work shall be made immediately by the Contractor, who shall compare it with the drawings and satisfy himself to conditions under which work is to be performed. He shall at such time ascertain and check locations of the existing structures and equipment which may affect his work. No allowance shall be made for any extra expense to which he may be due because of failure or neglect on his part to make such examinations. Any conflicts or omissions, etc., shall be reported to the Architect before proceeding with any work. WORK PERFORMED: All work listed, shown or implied on any construction document shall be supplied and installed by the Contractor except where noted. The Contractor shall closely coordinate his work with that of other contractors or vendors to assure that all schedules are met and that all work is done in conformance to manufacturers requirements. Work required under this Contract shall include all labor, materials, equipment, etc., necessary to complete this project. All materials shall be new and unused, unless specifically noted, and be of a quality acceptable by industry standards. ANY ERRORS, OMISSIONS, OR CONFLICTS found in the various parts of the construction documents shall be brought to the attention of the Architect and the Owner before proceeding with the work. ARCHITECT: Where referenced in notes, Architect shall be Mark Horton / Architecture. Client shall be referred to as "Owner." QUESTIONS: All questions regarding project either during bidding phase or during construction shall be directed to the Architect, Mark Horton / Architecture, at (415) 543-3347. C O N S T R U C T I O N SCHEDULE OF CONSTRUCTION: Contractor shall provide Architect and Owner with a complete cost breakdown and schedule of construction for this project prior to commencement of work. work. BUILDING CODES: All construction work, architectural, mechanical, plumbing. electrical, etc., shall conform to the 2013 Edition of the California Building Code and the latest edition of all governing codes and regulations as adopted by the local agencies. All work shall be done in a thorough, workmanlike manner and equal to the best standards of the practice. CONSTRUCTION DOCUMENTS: The Contractor shall maintain a current and complete Set of construction documents on the job site during all phases of construction for use of all trades and shall provide all subcontractors with current construction documents as required. The Contractor, in assuming responsibility for the work indicated, shall comply with the spirit as well as with the letter in which they were drawn. DETAILS: Details shown are typical. Similar details apply in similar conditions. DIMENSIONS: All dimensions on construction drawings are to face of structure, e.g., face of stud (F.O.S.), or face of concrete (F.O.C.), unless otherwise noted to be the Center Line of a mullion, a partition, or a column line, etc., or to Face of Finish for clear dimensions. Vertical dimensions are to top of plate or top of subfloor in section or elevation unless otherwise noted. All dimensions take precedence over scale. Any discrepancies shall be brought immediately to the attention of the Architect. Contractor shall not scale drawings. Questions regarding dimensions shall be brought to the attention of the Architect or Owner prior to any start of work. Where locations of windows and doors are not dimensioned they shall be centered on the wall or placed two stud widths from adjacent wall as indicated on the drawings. Window sizes and door head heights are nominal dimensions. Refer to manufacturer for actual rough opening sizes. 4'-6" FACE OF STRUCTURE COL. LCLC 1 2 CLR. DIM. PROVIDED: The use of the word 'provided' in connection with any item specified is intended to mean that such item shall be furnished, installed, and connected where so required, except as noted. MATERIALS: All materials for use on a project shall be stored within the project site. PROTECTION OF NEW MATERIALS: Contractor shall protect new materials and finishes from damage which may occur from construction, demolition, dust, water. etc., and shall provide and maintain temporary barricades, closure walls. etc., as required to protect the public as required during the period of construction. Damage to new materials, finishes, structures, and equipment shall be repaired or replaced. Contractor shall coordinate temporary barricades with Architect and / or Owner prior to commencement of SUBSTITUTIONS: Substitutions, revisions or changes must have approval by the architect prior to proceeding with the work. MATERIAL TRANSITIONS: All changes in floor materials occur at centerline of door or framed opening unless otherwise indicated on the drawings. DAMAGE: The Contractor shall repair or replace any surface or items damaged by construction to the satisfaction of the Architect and Owner. PATCHING: Properly prepare all surfaces for receiving the specified finishes including patching of surfaces altered by construction. On patched areas or areas where a finish is not specified, the finish shall match adjacent material in construction, color, and texture. WATERPROOFING: Sealant, caulking, and flashing, etc., locations shown on drawings are not intended to be inclusive. Follow manufacturer’s installation recommendations and standard industry and building practices. VENTILATION: All attics, rafter spaces, soffits, crawl spaces, etc., shall be fully ventilated. WOOD BACKING: Provide wood backing for all towel bars, etc. INSULATION: Install batt insulation between studs and joists at all exterior walls, ceilings, and floors where exposed, except where shown on the drawings. Verify with Title 24 Report for compliance when appropriate. ELECTRICAL, MECHANICAL, AND PLUMBING: All electrical, mechanical, and plumbing work and materials shall be in full accordance with the latest rules and regulations of the National Board of Fire Underwriters, The Safety Orders of the Division of Industrial Safety, and any applicable state or local laws and ordinance. Nothing on these drawings is to be construed to permit work not conforming to these codes. Any questions regarding installations shall be brought to the Architect for clarification. CONSTRUCTION DEBRIS: The Contractor shall remove all rubbish and waste materials of all subcontractors and trades on a regular basis, and shall exercise strict control over job cleaning to prevent any dirt, debris or dust from affecting in any way, finished areas in or outside the job site. CONTRACTOR'S PRESENCE: Contractor shall personally supervise and direct the work or shall keep a competent employee, authorized to receive instructions and act on the Contractor’s behalf, continuously on site during working hours. C L O S E O U T REVIEW PROJECT: Contractor shall review project with Architect and/or Owner to ensure that all requirements of the contract documents have been followed. CERTIFICATES AND NOTICES: Contractor shall obtain all required certificates and notices. CLEAN AND READY FOR USE: All work performed shall be clean and ready for use. PUNCH LIST: Upon SUBSTANTIAL COMPLETION, the CONTRACTOR shall compile a project punch list noting any corrections or omissions for review by the architect and Owner or Owner's representative. Architect’s acceptance will be cause for final payment, unless specifically determined otherwise by Owner. GUARANTEES: The Contractor shall guarantee that the project will be free of defects of workmanship and materials for a period of one year from the date of acceptance from the owner. No work defective in construction or quantity or deficient in any requirement of the drawings or notes will be acceptable in consequence of the Owner's or Architect's failure to discover or point out defects or deficiencies during construction. Defect of workmanship or materials revealed within a period of one year from the date of acceptance shall be replaced by work conforming with the intent of the contract at no cost to the Owner. No payment, partial or final, shall be construed as acceptance of defective work or improper materials. ABBREVIATIONS A.S.F.ABOVE SUB FLOOR ADJ.ADJUSTABLE A.F.F.ABOVE FINISH FLOOR ALUM.ALUMINUM ATTN.ATTENTION BATHRM.BATHROOM BLDG.BUILDING BLKG.BLOCKING BD.BOARD CAB.CABINETRY CL CENTER LINE CLG.CEILING CMU CONCRETE MASONRY UNIT COL.COLUMN CONC.CONCRETE CONT.CONTINUOUS CP CENTER POINT C.T.CERAMIC TILE DIA.DIAMETER DBL.DOUBLE DN DOWN DWGS.DRAWINGS EA.EACH E.J.EXPANSION JOINT ELEV.ELEVATION EQ.EQUAL EXIST'G EXISTING EXT.EXTERIOR F.B.O.FURNISHED BY OWNER F.O.F.FACE OF FINISH F.O.S.FACE OF STRUCTURE FIN.FINISH FLR.FLOOR GA.GAUGE GALV.GALVANIZED GL.GLASS GLU-LAM.GLUE LAMINATED GWB GYPSUM WALL BOARD HDWR HARDWARE H.M.HOLLOW METAL H.P.HIGH POINT HORIZ.HORIZONTAL HT.HEIGHT I.D.INSIDE DIMENSION J.B.JUNCTION BOX JT.JOINT LAM.LAMINATED LAV.LAVATORY L.P.LOW POINT MECH.MECHANICAL MIN.MINIMUM MR MOISTURE RESISTANT MT'L METAL N.I.C.NOT IN CONTRACT NOM.NOMINAL NTS NOT TO SCALE O.C.ON CENTER O.D.OUTSIDE DIMENSION O.H.OVERHEAD OPN'G OPENING OPP.OPPOSITE P.L.PROPERTY LINE P.LAM PLASTIC LAMINATE PLAS.PLASTER PLYWD.PLYWOOD PREFAB PREFABRICATED PT.POINT PTD.PAINTED QTY.QUANTITY R RISER RAD.RADIUS R.D.ROOF DRAIN REF.REFERENCE REG.REGISTER REINF.REINFORCING REQ'D REQUIRED RET.RETURN RM ROOM R.O.W.RIGHT OF WAY R.W.L.RAIN WATER LEADER SCHED.SCHEDULE SIM.SIMILAR SQ.SQUARE S.M.D.SEE MECHANICAL DRAWINGS S.S.D.SEE STRUCTURAL DRAWINGS S-ST'L.STAINLESS STEEL STD.STANDARD ST'L STEEL SUSP.SUSPENDED T TREAD T.B.D.TO BE DETERMINED T.O.TOP OF T.O.P.TOP OF PARAPET T.O.C.TOP OF CONCRETE T.O.W.TOP OF WALL THK.THICK VAR.VARIES VCT VINYL COMPOSITE TILE V.I.F.VERIFY IN FIELD W.C.WATER CLOSET WD WOOD VERBAL ABBREVIATIONS 9SANTA CLARA FIRE DEPARTMENT DEVELOPMENTAL REVIEW COMMENTS 17 COLUMN - GRID NUMBER DETAIL NUMBER / SHEET NUMBER DOOR NUMBER / TYPE DRAWING TITLE EQUIPMENT DESIGNATION NUMBER WINDOW TYPE NUMBER +8'-0"+8'-0" ELEVATION / REFERENCE TICK ROOM NAME AND NUMBER EXIT / EGRESS CENTER LINE INTERIOR ELEVATION REVISION CLOUD REVISION DELTA PROJECT NORTH AREA DRAIN SECTION / ELEVATION CL ALIGN OUTLET ELECTRICAL SWITCH TELEPHONE HOOKUP THERMOSTAT ALIGN OBJECTS TELEVISION CABLE HOOKUP INSULATION 1 1 A2.1 1 A2.1 DRAWING 1 1 A1.1 - A C D B AD PARTITION TYPE SCALE C D B A A3.4 2 ROOM 101 D-115 1 B1 COMMENT #1 REVIEW OF THIS DEVELOPMENTAL PROPOSAL IS LIMITED TO ACCEPTABILITY OF SITE ACCESS AND WATER SUPPLY AS THEY PERTAIN TO FIRE DEPARTMENT OPERATIONS, AND SHALL NOT BE CONSTRUED AS A SUBSTITUTE FOR FORMAL PLAN REVIEW TO DETERMINE COMPLIANCE WITH ADOPTED MODEL CODES. PRIOR TO PERFORMING ANY WORK THE APPLICANT SHALL MAKE APPLICATION TO, AND RECEIVE FROM, THE BUILDING DEPARTMENT ALL APPLICABLE CONSTRUCTION PERMITS. COMMENT #2 WILDLAND-URBAN INTERFACE: THIS PROJECT IS LOCATED WITHIN THE DESIGNATED WILDLAND-URBAN INTERFACE FIRE AREA. THE BUILDING CONSTRUCTION SHALL COMPLY WITH THE PROVISIONS OF CALIFORNIA BUILDING CODE (CBC) CHAPTER 7A. NOTE THAT VEGETATION CLEARANCE SHALL BE IN COMPLIANCE WITH CBC SECTION 701A.3.2.4 PRIOR TO PROJECT FINAL APPROVAL. CHECK WITH THE PLANNING DEPARTMENT FOR RELATED LANDSCAPE PLAN REQUIREMENTS. COMMENT #3 FIRE SPRINKLERS REQUIRED: AN AUTOMATIC RESIDENTIAL FIRE SPRINKLER SYSTEM SHALL BE INSTALLED IN ONE- AND TWO-FAMILY DWELLINGS AS FOLLOWS: IN ALL NEW ONE- AND TWO-FAMILY DWELLINGS AND IN EXISTING ONE- AND TWO-FAMILY DWELLINGS WHEN ADDITIONS ARE MADE THAT INCREASE THE BUILDING AREA TO MORE THAN 3,600 SQUARE FEET. EXCEPTION: A ONE-TIME ADDITION TO AN EXISTING BUILDINGTHAT DOES NOT TOTAL MORE THAN 1,000 SQUARE FEET OF BUILDING AREA. NOTE: THE OWNER(S), OCCUPANT(S), AND ANY CONTRACTOR(S) OR SUBCONTRACTOR(S) ARE RESPONSIBLE FOR CONSULTING WITH THE WATER PURVEYOR OF RECORD IN ORDER TO DETERMINE IF ANY MODIFICATION OR UPGRADE OF THE EXISTING WATER SERVICE IS REQUIRED. NOTE: COVERED PORCHES, PATIOS, BALCONIES, AND ATTIC SPACES MAY REQUIRE FIRE SPRINKLER COVERAGE. FOR BUILDINGS IN EXCESS OF 6,200 SQUARE FEET, THE (4) FOUR MOST HYDRAULICALLY DEMANDING HEADS IN A ROOM OR COMPARTMENT SHALL BE CALCULATED FIRE DEPARTMENT CONNECTION. FOR BUILDINGS IN EXCESS OF 6,200 SQUARE FEET, A FIRE DEPARTMENT CONNECTION (FDC) SHALL BE PROVIDED. THE FDC SHALL CONSIST OF AT LEAST ONE 2.5" HOSE CONNECTION THAT IS CONNECTED TO THE SPRINKLER RISER WITH A PIPE NOT LESS THAN THE DIAMETER OF THE SPRINKLER RISER. A STATE OF CALIFORNIA LICENSED (C-16) FIRE PROTECTION CONTRACTOR SHALL SUBMIT PLANS, CALCULATIONS, A COMPLETED PERMIT APPLICATION AND APPROPRIATE FEES TO THIS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO BEGINNING THEIR WORK. CRC SEC. 313.2 AS ADOPTED AND AMENDED BY LGTC. COMMENT #4 WATER SUPPLY REQUIREMENTS: POTABLE WATER SUPPLIES SHALL BE PROTECTED FROM CONTAMINATION CAUSED BY FIRE PROTECTION WATER SUPPLIES. IT IS THE RESPONSIBILITY OF THE APPLICANT AND ANY CONTRACTORS AND SUBCONTRACTORS TO CONTACT THE WATER PURVEYOR SUPPLYING THE SITE OF SUCH PROJECT, AND TO COMPLY WITH THE REQUIREMENTS OF THAT PURVEYOR. SUCH REQUIREMENTS SHALL BE INCORPORATED INTO THE DESIGN OF ANY WATER-BASED FIRE PROTECTION SYSTEMS, AND / OR FIRE SUPPRESSION WATER SUPPLY SYSTEMS OR STORAGE CONTAINERS THAT MAY BE PHYSICALLY CONNECTED IN ANY MANNER TO AN APPLIANCE CAPABLE OF CAUSING CONTAMINATION OF THE POTABLE WATER SUPPLY OF THE PURVEYOR OF RECORD. FINAL APPROVAL OF THE SYSTEM(S) UNDER CONSIDERATION WILL NOT BE GRANTED BY THIS OFFICE UNTIL COMPLIANCE WITH THE REQUIREMENTS OF THE WATER PURVEYOR OF RECORD ARE DOCUMENTED BY THAT PURVEYOR AS HAVING BEEN MET BY THE APPLICANT(S). 2010 CFC SEC. 903.3.5 AND HEALTH AND SAFETY CODE 13114.7. COMMENT #5 CONSTRUCTION SITE FIRE SAFETY: ALL CONSTRUCTION SITES MUST COMPLY WITH APPLICABLE PROVISIONS OF THE CFC CHAPTER 33 AND OUR STANDARD DETAIL AND SPECIFICATION SI-7. PROVIDE APPROPRIATE NOTATIONS ON SUBSEQUENT PLAN SUBMITTALS, AS APPROPRIATE TO THE PROJECT. CFC CHP. 33. COMMENT #6 ADDRESS IDENTIFICATION: NEW AND EXISTING BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. THESE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE ARABIC NUMBERS OR ALPHABETICAL LETTERS. NUMBERS SHALL BE A MINIMUM OF 4 INCHES (101.6 MM) HIGH WITH A MINIMUM STROKE WIDTH OF 0.5 INCH (12.7 MM). WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUIDLING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. CFC SEC. 505.1. GRAPHIC SYMBOLS 18 16114 A0.4 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 GENERAL NOTES &FIRE DEPT. GENERAL NOTES &FIRE DEPT. 16114 A0.5 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 CAL GREEN 16114 A0.6 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 CAL GREEN ⌀㤀 䜀爀愀礀MODIFIED BITUMEN ROOFTYPE: PARADIENE 30 FR TGCOLOR: BONE WHITESRI: 3-YEAR 28SOURCE: SIPLAST STUCCO TYPE: 20/30 FLOATCOLOR: SILVERADOLRV: 48SOURCE: LA HABRA WEST ELEVATION SCALE: 1/8" = 1'-0"10 NORTH ELEVATIONSCALE: 1/8" = 1'-0"11 EAST ELEVATIONSCALE: 1/8" = 1'-0"12 MATERIALS SCALE: N.T.S.18 C A F B E G GLASSTYPE: LOW E-3COLOR: CLEARLRV: 7SOURCE: SKYFRAME ALUMINUMTYPE: ANODIZED ALUMINUMCOLOR: BLACKLRV: 14SOURCE: SKY FRAME CONCRETETYPE: BOARD FORMED CONCRETECOLOR: TRAILS - FOSSILLRV: 11SOURCE: CONCRETE COLLABORATIVE WOODTYPE: WESTERN RED CEDARCOLOR: N/ALRV: 43SOURCE: POLYFLOR COMPOSITE WOODTYPE: N/ACOLOR: MOLESKINLRV: N/ASOURCE: GEOLAM WEST ELEVATION SF OF MATERIALS 1 NORTH ELEVATION SF OF MATERIALS 2 EAST ELEVATION SF OF MATERIALS 3 SOUTH ELEVATION SF OF MATERIALS 4 BUILDING LRV 5 A B E BD E E EE F F F B B E E E EE G A A AA B BBCC E E E D A AB E EE EB F A B B B E B E C A E E E E E A B B E A A A C C A A A B A B C B B E C E E E A A E G EF A C B EE E CC E B B B A A B B E E B A B A A B BC B F F E E E E E E E C E A CE E E C AA E C E C B B B B E STONETYPE: ASHLAR FOND DU LAC RUSTICCOLOR: LIGHT GRAY, WHITE, BROWN,BUFF, TAN & GOLDSR: 35.2SOURCE: PBMDH SOUTH ELEVATIONSCALE: 1/8" = 1'-0"13 16114 A0.7 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 MATERIALS A. GLASS 103.4B. ALUMINUM 102.4C. CONCRETE N/AD. STONE 6.9E. STUCCO 923.9F. WOOD 431.2G. COMPOSITE WOOD 29.7 TOTAL SF 1,597.5 A. GLASS 157.2B. ALUMINUM 60.1C. CONCRETE 757.6D. STONE 74.2E. STUCCO 401.5F. WOOD 200.2G. COMPOSITE WOOD N/A TOTAL SF 1,650.8 A. GLASS 999.6B. ALUMINUM 273.4C. CONCRETE 580.4D. STONE N/A E. STUCCO 818.3F. WOOD N/AG. COMPOSITE WOOD 29.1 TOTAL SF 2,700.8 A. GLASS 91.6B. ALUMINUM 105.9C. CONCRETE 445.8D. STONE N/AE. STUCCO 1,087.9F. WOOD 88.3G. COMPOSITE WOOD N/A TOTAL SF 1,819.5 % OF TOTAL SF 17.4723141.69.30.7 100 MATERIAL A. GLASSB. ALUMINUMC. CONCRETED. STONEE. STUCCOF. WOODG. COMPOSITE WOOD CUMULATIVE BUILDING LRV SF% x LRV 121.898253-1,996.8399.9- 2,869.5 29 TOTAL SFOF MATERIAL 1,351.8541.81,783.881.13,231.6719.758.8 7,768.6 LRV 71411-4843- EARTH MOVEMENT STOCKPILE 250 CY TRAILER WASH OUT PORTA POTTY DUMPSTER PARKING PARKINGPROJECT SCHEDULE Mobilization 04/16/18, 1 day Tree Protection 04/16/18, 1 day Tree Removal 04/17/18, 3 days Erosion Control 04/17/18, 1 week Grading/Drainage, 04/17/18, 2 months Construction Parking/Storage 04/30/18, 1.5 weeks Landscape 02/11/19, 6 months Completion 8/19/19 CONSTRUCTION MANAGEMENT PLAN Shoring at dripline of tree 688 and Type 1 tree protection. KEY NOTES PLAN NORTH EARTH MOVEMENT STOCKPILE 250 CY TRAILER WASH OUT PORTA POTTY DUMPSTER PARKING PARKINGPROJECT SCHEDULE Mobilization 04/16/18, 1 day Tree Protection 04/16/18, 1 day Tree Removal 04/17/18, 3 days Erosion Control 04/17/18, 1 week Grading/Drainage, 04/17/18, 2 months Construction Parking/Storage 04/30/18, 1.5 weeks Landscape 02/11/19, 6 months Completion 8/19/19 CONSTRUCTION MANAGEMENT PLAN Shoring at dripline of tree 688 and Type 1 tree protection. 16114 A0.8 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 CONSTRUCTIONMANAGEMENT PLAN CONSTRUCTIONMANAGEMENT PLAN CONSTRUCTION MANAGEMENT PLAN SCALE: 1" = 10'-0"17 718'-0" 718'-0" 717'-6" LOWER LEVELSCALE: 3/16" = 1'-0"17 WEST ELEVATION / SECTIONSCALE: 3/16" = 1'-0"10 SOUTH SECTIONSCALE: 3/16" = 1'-0"9 NORTH ELEVATIONSCALE: 3/16" = 1'-0"12 EXTENT OF CELLAR (A-B) 9 12 10 A 1 AREA OF CELLAR 694.8 SF AREA OF BASEMENT 1,090.4 SF 710' 708' 712' 716'718'720' (E) CONTOURS (N) SPOT ELEVATIONS 714' B 2 EXTENT OF GREATER THAN 8'-0" CUT (1-2)UPEXTENT OF CELLARA EXTENT OF CELLARB EXTENT OF GREATER THAN 8'-0" CUT1 EXTENT OF GREATER THAN 8'-0" CUT2 KEY NOTES 8'-0"T.O. FLOOR LOWER LEVEL 8'-0"4'-0"CELLAR DIMENSIONMAX. CUT DIMENSION(E) GRADE UNDERSIDE OF CEILING @ LOWER LEVEL A 1 1 B2 PLAN NORTH 711'-0" 713'-6" 707'-6" LOWER LEVEL 712'-3" 710'-3" 709'-6" 709'-6" 714'-9"714'-6" 718'-0" 716'-9" 16114 A0.9 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 CELLAR / BASEMENTDIAGRAM CELLAR /BASEMENT DIAGRAM 1.10'-0" PRIVATE SANITARY SEWER EASEMENT FOR LOT 9 SANITARY SEWER SERVICE. 2.EXISTING 5'-0" PUBLIC UTILITY EASEMENT (PUE) 3.LOCATION OF PUBLIC STORM DRAIN HAS NOT BEEN CONFIRMED. THE STORM DRAIN PIPE IS MOST LIKELY NOT WITHIN THE 10'-0" EASEMENT. SITE PLAN SCALE: 1" = 20'-0"17 PLAN NORTHUP57'-1 1/2"30'-8 7/8" xx 20'-0"xx 410707404 411 705 697 399 698 699 701 702 700 703 704 689 708 709 712 710 711 714 713 688 687 686 720 718 717 716 267 715 268 269 690 719 706 695 400 PRIVATE DRAINAGE EASEMENT S05°59'26"E 299.76'25'REARSETBACKS05°3 0 ' 1 9 " W 197.11' PRIVATE SCENIC EASEMENTHEAVY BRUSHDENSE TREESDENSE TREESDENSE TREESHEAVY BRUSH6 3 0 64 0659.2620 630 640 650 660 670 680 690 700 DENSE TREESDENSE TREESDENSE TREES692.9HEAVY BRUSHSANTELLACOURT401.04 'N48°14 '51 "E PROPERTY LINE (TYP) 10' PUBLIC STORM DRAINEASEMENT (SEE NOTE 3) LOT 9 UNBUILT PARCEL FUTURE PRIVATE SINGLE FAMILY RESIDENCE 20' SIDE SETBA C K LEAST RESTRICTIVEDEVELOPMENT AREA (LRDA)20'SIDESETBACKS03°42'12" E 153.10' SEE NOTE 1 22" LOT 11 (E) PRIVATE SINGLEFAMILY RESIDENCE18",19" 13" 20" 24" 15" 18" 15" 12" 14" 13" 16"19" 13" 24" 27" 8" 12" 19"16" 8" 14" 12",10" 15" 19" 8",12",13" 12",13",14" 22" 24"30'FRONTSETBACKR=42.00' 18"S87°40'08"E318.03'PROPERTY LINE (TYP) 27"32" 18",10" 26" 32" 28" 14" 15" 21" 41" 6",4"24",24" 25" 13" 13" 8" 11" 12"15" 15" 24" 26"19" SEE NOTE 2 20' SIDESETBA C K L= 6 1 .77 ' ∆= 8 4 ° 1 5 ' 5 4 " 16114 A1.1 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 SITE PLAN KEY NOTES TREES 697, 705, 707, 399, 404, 410 ARE LABELED BY THE ARBORISTAND ARE SHOWN COVERING THE HOUSE TREES SHOWN IN VISIBILITY STUDY CUT AND FILL / BUILDING HEIGHT TABLE LOCATION(E) GRADE(N) GRADECUTFILLT.O. STRUCTUREHEIGHT ABOVE (E) GRADEHEIGHT ABOVE (N) GRADE1 718'-9"714'-9"4'-0"-732'-0"13'-3"17'-3" 2 718'-6"714'-6"4'-0"-732'-0"13'-6"17'-6" 3 714'-9"714'-9"--732'-0"17'-3"17'-3" 4 714'-9"712'-3"2'-6"-732'-0"17'-3"19'-9" 5 714'-3"710'-3"4'-0"-732'-0"17'-9"21'-9" 6 715'-0"711'-0"4'-0"-732'-0"17'-0"21'-0" 7 712'-3"709'-6"2'-9"-732'-0"19'-9"22'-6" 8 712'-6"709'-6"3'-0"-732'-0"19'-6"22'-6" 9 713'-3"709'-6"3'-9"-732'-0"18'-9"22'-6" 10 710'-6"707'-0"3'-6"-732'-0"21'-6"25'-0" 11 710'-0"707'-0"3'-0"-711'-6"1'-6"4'-6" 12 708'-3"707'-0"1'-3"-711'-6"3'-3"4'-6" 13 705'-6"705'-6"--709'-6"4'-0"4'-0" 14 706'-0"706'-0"--710'-6"4'-6"4'-6" 15 704'-6"704'-6"--710'-6"6'-0"6'-0" 16 706'-6"706'-6"--711'-6"5'-0"5'-0" 17 705'-6"705'-6"--711'-6"6'-0"6'-0" 18 707'-0"707'-0"--711'-6"4'-6"4'-6" 19 704'-0"704'-0"--704'-6"0'-6"0'-6" 20 706'-0"706'-0"--713'-6"7'-6"7'-6" 21 707'-6"707'-6"--732'-0"24'-6"24'-6" 22 709'-0"709'-0"--732'-0"23'-0"23'-0" 23 714'-0"714'-0"--732'-0"18'-0"18'-0" 24 710'-6"710'-6"--711'-0"0'-6"0'-6" 25 711'-0"710'-6"0'-6"-711'-0"0'-0"0'-6" 26 713'-0"713'-0"--728'-6"15'-6"15'-6" 27 715'-0"715'-0"--730'-0"15'-0"15'-0" 28 716'-0"718'-3"-2'-3"730'-0"14'-0"11'-9" 29 718'-0"718'-3"-0'-3"730'-0"12'-0"11'-9" 30 720'-3"718'-3"2'-0"-732'-0"11'-9"13'-9" 31 718'-0"718'-0"--732'-0"14'-0"14'-0" 32 719'-0"718'-0"1'-0"-732'-0"13'-0"14'-0" 33 720'-0"718'-0"2'-0"-732'-0"12'-0"14'-0" 34 719'-0"718'-0"1'-0"-732'-0"13'-0"14'-0" 35 718'-9"718'-0"0'-9"-732'-0"13'-3"14'-0" 36 713'-0"707'-6"5'-6"-732'-0"19'-0"24'-6" 37 714'-0"707'-6"6'-6"-732'-0"18'-0"24'-6" 38 712'-3"708'-6"3'-9"-732'-0"19'-9"23'-6" 39 714'-9"711'-3"3'-6"-732'-0"17'-3"20'-9" 40 709'-6"708'-9"0'-9"-729'-6"20'-0"20'-9" 41 707'-6"707'-6"--729'-6"22'-0"22'-0" 42 711'-0"708'-3"2'-9"-732'-0"21'-0"23'-9"UP700 24" 19" 13" 15" 14" 8" 16"19" 12" 8" 18" 12",10" 18",19" 18",10"26" 32" 6",4" 14" 22" 15" 19" 8",12",13" 12",13",14" 25" 8"13" 11" 12" 15" 15" 24" 706 705 697 698 699 701 700 702 704 703 690 687 686 688 269 410 713 404 707 689 708 709 710 711 714 720 719 411 712 715 716 717 267 718 720'718'716'714'712'710'708'706'704'702'700' 708' 706' 704' 702' 700' 724' 722' 720' 718' 716' 714' 712' 710' 708' 706' 704' 702' 700' 698' 696' 694' 692' 690' 688' 686' 684' SITE PLAN LEGEND REMOVE TREE SAVE TREE - TREE TRUNK DIAMETER SAVE TREE - HOUSE RESTRICTION SAVE TREE - GRADING RESTRICTION SAVE TREE - POSTS RESTRICTION SAVE TREE - RETAINING WALL RESTRICTION SAVE TREE - SEWER / PIPES RESTRICTION SAVE TREE - GRASS / DISTURBANCE RESTRICTION SAVE TREE - DRIVEWAY / PATHWAYS RESTRICTION DEBATABLE - HOUSE RESTRICTION DEBATABLE - GRADING RESTRICTION DEBATABLE - POSTS RESTRICTION DEBATABLE - RETAINING WALL RESTRICTION DEBATABLE - SEWER / PIPES RESTRICTION DEBATABLE - GRASS / DISTURBANCE RESTRICTION DEBATABLE - DRIVEWAY / PATHWAYS RESTRICTION DEBATABLE - TREE TRUNK DIAMETER 1 3 4 6 5 2 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 32 3435 404 36 37 38 39 40 41 SEE SHEET C3.0 FOR TREE PROTECTION PLAN (FENCING). IN ADDITION TO PROTECTIVE FENCING, SPECIFIC TREES WILL REQUIRE TRUNK PROTECTIVE WRAPPING (2” OF ORANGE PLASTIC FENCING OVERLAYING 2” THICK WOODEN SLATS). TREES TO BE WRAPPED ARE:686687688 (THIS TREE MAY BE REMOVED DURING CONSTRUCTION)704706707716717718719ALSO, CREATE A ROOT ARMORING SYSTEM FOR THESE TREES TO INCLUDE 4 - 6 INCHES OF MULCH AND PLYWOOD TO PROTECT THE SOIL FROM COMPACTION AND EQUIPMENT. TREE PROTECTION NOTES TREES 697, 705, 707, 399, 404, 410 ARE LABELED BY THE ARBORISTAND ARE SHOWN COVERING THE HOUSE TREES SHOWN IN VISIBILITY STUDY 42 16114 A1.2 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 SITE PLAN KEY NOTES SITE PLAN SCALE: 1/8" = 1'-0"17 PLAN NORTH 1 WOOD BACKING (2" X 8" MINIMUM) TO BE PROVIDED IN ALL BATHROOM WALLS, AT WATER CLOSETS, SHOWERS, AND BATHTUBS. BACKING TO BE 34" A.F.F. TO CENTERLINE, SUITABLE FOR INSTALLATION OF GRAB BARS AT FUTURE DATE. 16114 A2.1 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 FLOOR PLAN LOWER LEVEL SCALE: 3/16" = 1'-0"17 PLAN NORTH KEY NOTES 712'-3" 709'-6" 710'-3" 711'-0" 707-0" 707'-0" 706'-0" 718'-0" 706'-6" 707'-6" 709'-0" 714'-0" 707'-6" LOWER LEVEL 707'-6" LOWER LEVEL 707'-0" 704'-0" 710'-6" 705'-6" 704'-6" 705'-6" 704'-0" 710'-6" 714'-9"UPB B 4 4 6 5 D F 3 3 1 1 E E 9 A4.2 C BD A 17 A4.3 C BD A 17 A4.2 C BD A 9 A4.4 C BD A 17 A4.4 C BD A 6 5 D F BEDROOM L07 OFFICE / PLAY L04 WINE L02 CLOSET L09 BATHROOM L08 CORRIDOR L10 BEDROOM L11 BATHROOM L12 5 A2.4 9 A6.1 13 A2.4 17 A2.4 W-01 W-02.2 W-06.1 W-05 W-04 W-03 W-06.2 W-02.1 W-07 W-08 xx xx I-A C-A xx xx I-B I-B I-A I-B I-A I-A I-A I-B I-B I-O I-A I-O C-E C-A C-A C-A I-D I-B I-B I-O I-C xx xx xx xx xx D-06 D-07 D-05 D-01 D-02 D-09 A A 9 A4.1 BDCORRIDOR L01 5 A4.2 C BD A CLOSET L03 714'-6" 713'-6" 709'-6" 717'-6" 16114 A2.2 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 FLOOR PLAN 1 WOOD BACKING (2" X 8" MINIMUM) TO BE PROVIDED IN ALL BATHROOM WALLS, AT WATER CLOSETS, SHOWERS, AND BATHTUBS. BACKING TO BE 34" A.F.F. TO CENTERLINE, SUITABLE FOR INSTALLATION OF GRAB BARS AT FUTURE DATE. KEY NOTES MAIN LEVEL SCALE: 3/16" = 1'-0"17 PLAN NORTH 713'-0" 707'-0" 714'-6"716'-9" UPUPUPUP STAIR 2 STAIR 3 9 A2.5 13 6.2 17 A6.213 A2.5 10 A6.1 15 A2.5 19 A2.4 7 A2.4 20 A6.2 9 A4.13 C D A 13 A4.6 C BD A 9 A4.7 C BD A 17 A4.8 C BD A 9 A4.9 C BD A 17 A4.10 C BD A 17 A4.7 C BD A W-17 W-16 W-15 W-14 W-13 W-12 W-11 W-10 W-19 BEDROOM 107 OFFICE 105 CLOSET 104 TERRACE 106 BATHROOM 108 ENTRY 101 CORRIDOR 112 PANTRY 114 STORAGE 117 KITCHEN 110 LIVING ROOM 111 GARAGE 116 LAUNDRY 115 MECHANICAL 118 BRIDGE 102 STAIR 1 103 TERRACE 109 BATHROOM 113 D-10 D-12 D-13 D-14D-15 D-16 D-19 D-20 D-21 D-22 D-23 D-24 D-27 D-26 D-11 D-18 D-25 xx I-A xx I-M I-M I-M I-B xx xxI-A xx I-C I-A I-B xx C-E I-A I-A xx xxxx I-B I-A I-A xx xx I-B I-B xx xx xx I-M I-M xx xx C-A I-A I-A I-P C-G I-A I-A I-A xx xx 17 A4.14 C BD A 17 A4.13 C BD A 9 A4.14 C BD A I-M I-M 9 A4.11 C A D UP UPUP B4 6 5 D 3 1 EA F 17 A4.6 C BD AUP 6 5 D F B43 1 EA 714'-9" A4.11B13 A4.11 D13 A A4.11 13 C A4.11 13 710'-6" 716'-6" LIVING / KITCHEN LEVEL 718'-3 1/2" GARAGE718'-0" 718'-0"718'-0" 718'-3" 718'-3" 718'-3" 715'-0" 716'-6" 717'-4 1/2" T.O. WALL 724'-0" T.O. WALL 711'-6" 705'-6" 704'-6" 705'-6" 709'-0" 709'-6" 710'-6" 712'-6" 712'-0" 704'-0" 718'-6" MAIN LEVEL 713'-6" TERRACE LEVEL 704'-0" 716'-9" 718'-6" 721'-6" T.O. WALL 710'-0" UPSL-01 SL-02 SL-03 SL-04 SL-05 C C C B A B4 6 5 D 3 1 EA F UP6 5 D F B43 1 EA 16114 A2.3 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 ROOF PLAN 1 WOOD BACKING (2" X 8" MINIMUM) TO BE PROVIDED IN ALL BATHROOM WALLS, AT WATER CLOSETS, SHOWERS, AND BATHTUBS. BACKING TO BE 34" A.F.F. TO CENTERLINE, SUITABLE FOR INSTALLATION OF GRAB BARS AT FUTURE DATE. KEY NOTES ROOF PLAN SCALE: 3/16" = 1'-0"17 PLAN NORTH (E) GRADE @ FRONT OF BUILDING 25'-0" ABOVE (E) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT (N) GRADE @ FRONT OF BUILDING (E) GRADE @ FACE OF BUILDING 25'-0" ABOVE (E) GRADE @ FACE OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FACE OF BUILDING - MAXIMUM BUILDING HEIGHT A B C D E F G H (N) GRADE @ FACE OF BUILDING EAST ELEVATION SCALE: 3/16" = 1'-0"17 WEST ELEVATIONSCALE: 3/16" = 1'-0"19 732'-0" T.O. ROOF 742'-6" 35'-0" ABOVE LOWEST LOWESTCONSTRUCTEDPOINT BLDG. ELEMENT 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL C A 707'-6" F.F. LOWER LEVEL / 704'-'0" LOWEST CONSTRUCTED 739'-0" 35'-0" ABOVE LOWEST POINT BLDG. ELEMENT A C 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL 707'-6" F.F. LOWER LEVEL 16114 A3.1 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 ELEVATIONS KEY NOTES 704'-0" LOWEST CONSTRUCTED 707'-6" F.F. LOWER LEVEL 739'-0" 35'-0" ABOVE LOWEST POINT BLDG. ELEMENT A C 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL 707'-6" F.F. LOWER LEVEL 742'-0" 35'-0" ABOVE LOWESTBLDG. ELEMENT POINT C A 707'-0" LOWEST CONSTRUCTED 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL (E) GRADE @ FRONT OF BUILDING 25'-0" ABOVE (E) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT (N) GRADE @ FRONT OF BUILDING (E) GRADE @ FACE OF BUILDING 25'-0" ABOVE (E) GRADE @ FACE OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FACE OF BUILDING - MAXIMUM BUILDING HEIGHT A B C D E F G H (N) GRADE @ FACE OF BUILDING SOUTH ELEVATION SCALE: 3/16" = 1'-0"17 NORTH ELEVATIONSCALE: 3/16" = 1'-0"19 16114 A3.2 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 ELEVATIONS KEY NOTES (E) GRADE @ FRONT OF BUILDING 25'-0" ABOVE (E) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT (N) GRADE @ FRONT OF BUILDING (E) GRADE @ FACE OF BUILDING 25'-0" ABOVE (E) GRADE @ FACE OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FACE OF BUILDING - MAXIMUM BUILDING HEIGHT A B C D E F G H (N) GRADE @ FACE OF BUILDING 707'-6" F.F. LOWER LEVEL / 742'-6" 35'-0" ABOVE LOWEST D B LOWESTCONSTRUCTEDPOINT BLDG. ELEMENT C A 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL 707'-6" F.F. LOWER LEVEL / 742'-6" 35'-0" ABOVE LOWEST D B LOWESTCONSTRUCTEDPOINT BLDG. ELEMENT A C 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL LONGITUDINAL SECTION 5 (AT ENTRY) SCALE: 3/16" = 1'-0"17 LONGITUDINAL SECTION F (THROUGH STAIRWELL)SCALE: 3/16" = 1'-0"19 16114 A3.3 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 SECTIONS KEY NOTES 742'-6" 35'-0" ABOVE LOWEST 707'-6" F.F. LOWER LEVEL B A C D BLDG. ELEMENT 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL 707'-6" F.F. LOWER LEVEL / 742'-6" 35'-0" ABOVE LOWEST LOWESTCONSTRUCTEDPOINT BLDG. ELEMENT B D A C 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL (E) GRADE @ FRONT OF BUILDING 25'-0" ABOVE (E) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT (N) GRADE @ FRONT OF BUILDING (E) GRADE @ FACE OF BUILDING 25'-0" ABOVE (E) GRADE @ FACE OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FACE OF BUILDING - MAXIMUM BUILDING HEIGHT A B C D E F G H (N) GRADE @ FACE OF BUILDING LONGITUDINAL SECTION D (ALONG EAST) SCALE: 3/16" = 1'-0"17 LONGITUDINAL SECTION 6 (ALONG WEST)SCALE: 3/16" = 1'-0"19 16114 A3.4 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 SECTIONS KEY NOTES 707'-6" F.F. LOWER LEVEL POINT B A C D FACE OF BUILING @ CONCRETEEFGH NOTES G E H F 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL 707'-0" LOWEST CONSTRUCTED 742'-0" 35'-0" ABOVE LOWESTBLDG. ELEMENT 707'-6" F.F. LOWER LEVEL 739'-6" 35'-0" ABOVE LOWEST 704'-6" LOWEST CONTSRUCTEDPOINT BLDG. ELEMENT C D A B FACE OF BUILING @ CONCRETEEFGH NOTES G E H F 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL (E) GRADE @ FRONT OF BUILDING 25'-0" ABOVE (E) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT (N) GRADE @ FRONT OF BUILDING (E) GRADE @ FACE OF BUILDING 25'-0" ABOVE (E) GRADE @ FACE OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FACE OF BUILDING - MAXIMUM BUILDING HEIGHT A B C D E F G H (N) GRADE @ FACE OF BUILDING TRANSVERSE SECTION 1 (THROUGH LIVING ROOM) SCALE: 3/16" = 1'-0"17 TRANSVERSE SECTION E (ALONG SOUTH)SCALE: 3/16" = 1'-0"19 16114 A3.5 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 SECTIONS KEY NOTES 742'-6" 35'-0" ABOVE LOWEST 707'-6" F.F. LOWER LEVEL /LOWEST CONSTRUCTED POINT BLDG. ELEMENT C D A B 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL 707'-6" F.F. LOWER LEVEL 742'-6" 35'-0" ABOVE LOWESTBLDG. ELEMENT C D A B 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL (E) GRADE @ FRONT OF BUILDING 25'-0" ABOVE (E) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT (N) GRADE @ FRONT OF BUILDING (E) GRADE @ FACE OF BUILDING 25'-0" ABOVE (E) GRADE @ FACE OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FACE OF BUILDING - MAXIMUM BUILDING HEIGHT A B C D E F G H (N) GRADE @ FACE OF BUILDING TRANSVERSE SECTION 3 (THROUGH GLASS BRIDGE) SCALE: 3/16" = 1'-0"17 TRANSVERSE SECTION B (THROUGH LIVING ROOM)SCALE: 3/16" = 1'-0"19 16114 A3.6 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 SECTIONS KEY NOTES 707'-6" F.F. LOWER LEVEL / 742'-6" 35'-0" ABOVE LOWESTBLDG. ELEMENT A B C D 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL 707'-6" F.F. LOWER LEVEL 742'-0" 35'-0" ABOVE LOWESTBLDG. ELEMENT C D A B POINT 707'-0" LOWEST CONSTRUCTED 732'-0" T.O. ROOF 730'-0" T.O. GARAGE ROOF 718'-6" F.F. MAIN LEVEL 718'-3 1/2" GARAGE LEVEL 718'-0" EXT. GRADE @FRONT ENTRY 716'-6" LIVING LEVEL 713'-6" TERRACE LEVEL (E) GRADE @ FRONT OF BUILDING 25'-0" ABOVE (E) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FRONT OF BUILDING -MAXIMUM BUILDING HEIGHT (N) GRADE @ FRONT OF BUILDING (E) GRADE @ FACE OF BUILDING 25'-0" ABOVE (E) GRADE @ FACE OF BUILDING -MAXIMUM BUILDING HEIGHT 25'-0" ABOVE (N) GRADE @ FACE OF BUILDING - MAXIMUM BUILDING HEIGHT A B C D E F G H (N) GRADE @ FACE OF BUILDING 16114 A3.7 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 SECTIONS KEY NOTES TRANSVERSE SECTION A (THROUGH ENTRY) SCALE: 3/16" = 1'-0"17 TRANSVERSE SECTION 4 (ALONG NORTH)SCALE: 3/16" = 1'-0"19 BATHROOM L08 SCALE: 3/8" = 1'-0"13 1'-1"2'-2"EQ. 4'-4"1'-1"3'-0"6"6"4"6"1"1'-1" 2'-0"EQ.3'-9"1'-4"6"2'-0"10'-0"3'-5"3'-4"8"8"8"EQ.EQ.EQ.EQ. EQ.EQ. 7'-6"2'-0"1'-4"3'-4"1"4"4"4"1"6'-10"6"2'-0"10'-0"2'-0" EQ.3'-9"3'-4"4"4"1"4"EQ. 8'-9" 6'-9" CLOSET L09 SCALE: 3/8" = 1'-0"17 BATHROOM L08 (TOILET) SCALE: 3/8" = 1'-0"9 BATHROOM L08 (SHOWER) SCALE: 3/8" = 1'-0"5 1 1 B A C D B A C D B A C D B A C D 16114 A4.3 REVISIONS JOB NUMBER DRAWN BY JT SCALE DATE FOR 11 OCTOBER 2017 PLANNING REVIEW RESUBMITTAL AS NOTED OWNERSHIP OF INSTRUMENTS OF SERVICEALL REPORTS, PLANS, SPECIFICATIONS, COMPUTER FILES, FIELD DATA, NOTES AND OTHER DOCUMENTS AND INSTRUMENTS PREPARED BY THE CONSULTANT AS INSTRUMENTS OF SERVICE SHALL REMAIN THE PROPERTY OF THE CONSULTANT. THE CONSULTANT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. VISOSO 15358 SANTELLACOURT LOS GATOS,CALIFORNIA95032 INTERIOR ELEVATIONS KEY NOTES 1 WOOD BACKING (2" X 8" MINIMUM) TO BE PROVIDED IN ALL BATHROOM WALLS, AT WATER CLOSETS, SHOWERS, AND BATHTUBS. BACKING TO BE 34" A.F.F. TO CENTERLINE, SUITABLE FOR INSTALLATION OF GRAB BARS AT FUTURE DATE. 09/06/17 09/06/17 09/06/17 09/06/17 09/06/17 09/06/17 09/06/17 09/06/17 09/06/17 09/06/17 09/06/17 09/06/17 REVISIONS:BY:PRELIMINARY - NOT FOR CONSTRUCTION OR BUILDING DEPARTMENT SUBMITTAL OR REVIEW cad@meg4.com www.montereyenergygroup.com 831-359-4173 FAX 831-372-8328 VOICE 26465 Carmel Rancho Blvd. Suite 8, Carmel, CA 93923 Consulting Mechanical Engineering VISOSO RESIDENCE 15358 SANTELLA COURT LOS GATOS, CA. 9503202/28/17SHEET:CHECKED:FILE NAME:CHECKED:DRAWN:SCALE:DATE:REVISIONS:BY:SOLAR PHOTOVOLTAIC ROOF LAYOUT & NOTES MEGPV2.1SHEET OF SHEETSAS NOTED REVISIONS:BY:VISOSORESIDENCE15358 SANTELLA COURTLOS GATOS, CA. 9503203/15/17MONTEREY ENERGY GROUPConsulting Mechanical Engineering26465 Carmel Rancho Blvd. Suite 8, Carmel, CA 93923831-372-8328 VOICE 831-359-4173 FAX www.montereyenergygroup.comcad@meg4.comPRELIMINARY - NOT FOR CONSTRUCTION OR BUILDING DEPARTMENT SUBMITTAL OR REVIEWTITLE TO THESE DRAWINGS AND SPECIFICATIONS REMAINS WITH THE ENGINEER WITHOUT PREJUDICE. VISUAL CONTACT WITH THESE DRAWINGS AND SPECIFICATIONS SHALL CONSTITUTE PRIMA FACIA EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.THE USE OF THESE DRAWINGS AND SPECIFICATIONS IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REPRODUCTION OR PUBLICATION BY ANY MEANS, IN WHOLE OR IN PART, IS PROHIBITED.MONTEREY ENERGY GROUP, INC.SHEET: CHECKED: FILE NAME: CHECKED: DRAWN: SCALE: DATE: REVISIONS:BY: AS NOTEDNOTES MEG M0.1 SHEET OF SHEETS VERSA HYDRO PRE-START-UP RADIANT HEATING NOTESRADIANT DESIGN SUMMARY REVISIONS:BY:VISOSORESIDENCE15358 SANTELLA COURTLOS GATOS, CA. 9503203/15/17MONTEREY ENERGY GROUPConsulting Mechanical Engineering26465 Carmel Rancho Blvd. Suite 8, Carmel, CA 93923831-372-8328 VOICE 831-359-4173 FAX www.montereyenergygroup.comcad@meg4.comPRELIMINARY - NOT FOR CONSTRUCTION OR BUILDING DEPARTMENT SUBMITTAL OR REVIEWTITLE TO THESE DRAWINGS AND SPECIFICATIONS REMAINS WITH THE ENGINEER WITHOUT PREJUDICE. VISUAL CONTACT WITH THESE DRAWINGS AND SPECIFICATIONS SHALL CONSTITUTE PRIMA FACIA EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.THE USE OF THESE DRAWINGS AND SPECIFICATIONS IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REPRODUCTION OR PUBLICATION BY ANY MEANS, IN WHOLE OR IN PART, IS PROHIBITED.MONTEREY ENERGY GROUP, INC.SHEET: CHECKED: FILE NAME: CHECKED: DRAWN: SCALE: DATE: REVISIONS:BY: AS NOTEDNOTES MEG M0.2 SHEET OF SHEETS ABBREVIATIONS T SIZE SIZE SIZE SIZE SIZE MECHANICAL LEGEND DUCT SYSTEM INSTALLATION REGISTERS FANS FAN CONVECTORS AIR HANDLERS HEAT PUMPS REVISIONS:BY:VISOSORESIDENCE15358 SANTELLA COURTLOS GATOS, CA. 9503203/15/17MONTEREY ENERGY GROUPConsulting Mechanical Engineering26465 Carmel Rancho Blvd. Suite 8, Carmel, CA 93923831-372-8328 VOICE 831-359-4173 FAX www.montereyenergygroup.comcad@meg4.comPRELIMINARY - NOT FOR CONSTRUCTION OR BUILDING DEPARTMENT SUBMITTAL OR REVIEWTITLE TO THESE DRAWINGS AND SPECIFICATIONS REMAINS WITH THE ENGINEER WITHOUT PREJUDICE. VISUAL CONTACT WITH THESE DRAWINGS AND SPECIFICATIONS SHALL CONSTITUTE PRIMA FACIA EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.THE USE OF THESE DRAWINGS AND SPECIFICATIONS IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REPRODUCTION OR PUBLICATION BY ANY MEANS, IN WHOLE OR IN PART, IS PROHIBITED.MONTEREY ENERGY GROUP, INC.SHEET: CHECKED: FILE NAME: CHECKED: DRAWN: SCALE: DATE: REVISIONS:BY: 1 MAIN LEVEL RADIANT HEATING PLAN SCALE: 1/4" = 1'-0"MAIN LEVELRADIANT HEATING PLANMEG M2.1 SHEET OF SHEETS AS NOTED SHEET NOTES NORTH ARROW N REVISIONS:BY:VISOSORESIDENCE15358 SANTELLA COURTLOS GATOS, CA. 9503203/15/17MONTEREY ENERGY GROUPConsulting Mechanical Engineering26465 Carmel Rancho Blvd. Suite 8, Carmel, CA 93923831-372-8328 VOICE 831-359-4173 FAX www.montereyenergygroup.comcad@meg4.comPRELIMINARY - NOT FOR CONSTRUCTION OR BUILDING DEPARTMENT SUBMITTAL OR REVIEWTITLE TO THESE DRAWINGS AND SPECIFICATIONS REMAINS WITH THE ENGINEER WITHOUT PREJUDICE. VISUAL CONTACT WITH THESE DRAWINGS AND SPECIFICATIONS SHALL CONSTITUTE PRIMA FACIA EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.THE USE OF THESE DRAWINGS AND SPECIFICATIONS IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REPRODUCTION OR PUBLICATION BY ANY MEANS, IN WHOLE OR IN PART, IS PROHIBITED.MONTEREY ENERGY GROUP, INC.SHEET: CHECKED: FILE NAME: CHECKED: DRAWN: SCALE: DATE: REVISIONS:BY: 1 LOWER LEVEL RADIANT HEATING PLAN SCALE: 1/4" = 1'-0"LOWER LEVELRADIANT HEATING PLANMEG M2.2 SHEET OF SHEETS AS NOTED NORTH ARROW N REVISIONS:BY:VISOSORESIDENCE15358 SANTELLA COURTLOS GATOS, CA. 9503203/15/17MONTEREY ENERGY GROUPConsulting Mechanical Engineering26465 Carmel Rancho Blvd. Suite 8, Carmel, CA 93923831-372-8328 VOICE 831-359-4173 FAX www.montereyenergygroup.comcad@meg4.comPRELIMINARY - NOT FOR CONSTRUCTION OR BUILDING DEPARTMENT SUBMITTAL OR REVIEWASHRAE 62.2 VENTILATION SHEET NOTES TITLE TO THESE DRAWINGS AND SPECIFICATIONS REMAINS WITH THE ENGINEER WITHOUT PREJUDICE. VISUAL CONTACT WITH THESE DRAWINGS AND SPECIFICATIONS SHALL CONSTITUTE PRIMA FACIA EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.THE USE OF THESE DRAWINGS AND SPECIFICATIONS IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REPRODUCTION OR PUBLICATION BY ANY MEANS, IN WHOLE OR IN PART, IS PROHIBITED.MONTEREY ENERGY GROUP, INC.SHEET: CHECKED: FILE NAME: CHECKED: DRAWN: SCALE: DATE: REVISIONS:BY: 1 LOWER LEVEL COOLING AND VENTILATION PLAN SCALE: 1/4" = 1'-0"LOWER LEVELVENTILATION PLANMEG M2.3 SHEET OF SHEETS AS NOTED NORTH ARROW N REVISIONS:BY:VISOSORESIDENCE15358 SANTELLA COURTLOS GATOS, CA. 9503203/15/17MONTEREY ENERGY GROUPConsulting Mechanical Engineering26465 Carmel Rancho Blvd. Suite 8, Carmel, CA 93923831-372-8328 VOICE 831-359-4173 FAX www.montereyenergygroup.comcad@meg4.comPRELIMINARY - NOT FOR CONSTRUCTION OR BUILDING DEPARTMENT SUBMITTAL OR REVIEWASHRAE 62.2 VENTILATION SHEET NOTESTITLE TO THESE DRAWINGS AND SPECIFICATIONS REMAINS WITH THE ENGINEER WITHOUT PREJUDICE. VISUAL CONTACT WITH THESE DRAWINGS AND SPECIFICATIONS SHALL CONSTITUTE PRIMA FACIA EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.THE USE OF THESE DRAWINGS AND SPECIFICATIONS IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REPRODUCTION OR PUBLICATION BY ANY MEANS, IN WHOLE OR IN PART, IS PROHIBITED.MONTEREY ENERGY GROUP, INC.SHEET: CHECKED: FILE NAME: CHECKED: DRAWN: SCALE: DATE: REVISIONS:BY: 1 MAIN FLOOR COOLING AND VENTILATION PLAN SCALE: 1/4" = 1'-0"MAIN FLOOR VENTILATION PLANMEG M2.4 SHEET OF SHEETS AS NOTED NORTH ARROW N REVISIONS:BY:VISOSORESIDENCE15358 SANTELLA COURTLOS GATOS, CA. 9503203/15/17MONTEREY ENERGY GROUPConsulting Mechanical Engineering26465 Carmel Rancho Blvd. Suite 8, Carmel, CA 93923831-372-8328 VOICE 831-359-4173 FAX www.montereyenergygroup.comcad@meg4.comPRELIMINARY - NOT FOR CONSTRUCTION OR BUILDING DEPARTMENT SUBMITTAL OR REVIEWTITLE TO THESE DRAWINGS AND SPECIFICATIONS REMAINS WITH THE ENGINEER WITHOUT PREJUDICE. VISUAL CONTACT WITH THESE DRAWINGS AND SPECIFICATIONS SHALL CONSTITUTE PRIMA FACIA EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.THE USE OF THESE DRAWINGS AND SPECIFICATIONS IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REPRODUCTION OR PUBLICATION BY ANY MEANS, IN WHOLE OR IN PART, IS PROHIBITED.MONTEREY ENERGY GROUP, INC.SHEET: CHECKED: FILE NAME: CHECKED: DRAWN: SCALE: DATE: REVISIONS:BY:PIPING SCHEMATICMEG M6.1 SHEET OF SHEETS AS NOTED WH-1 130.0 120.0 120/1 6.3 3/4"1"933.0 95.0 HEAT TRANSFER PHE 130-80 B3 SUPPLYRETURNVersa-Hydro EY[1 HEATING SYSTEM PIPING SCHEMATIC-Versa-Hydro COMBINATION HEATING AND DHW NOT TO SCALE HW/ CW CON. PUMPS SYSTEM COMPONENTS NOTES WT LBS MANUF. MODELMANUF.GPM FT HDMARK L H G F C B A MARK COMPONENT MARK IN OUT KBTUH FAN AMPSV/PH GAS CON. HP NOTES V/PH AMPS EFF. (%) MOTOR 12 NOTESMODEL B1-B4 AFUE MANUFACTURER AND MODEL NOTES WATER HEATING DEVICES 11 E J P1-P2 TEMP/PRESSURE GUAGE MILJOCO PB300804 TEMPERATURE GUAGE MILJOCO B259951-2W TELESTAT WATTS - P-1 CONDENSATE COMBUSTION AIR INTAKE CONN (SEE VENTING SHEET) 6 9 P-2 AUXILIARY PORT (NOT USED) AUXILIARY PORT (NOT USED) 1" COMBUSTION AIR EXHAUST CONN (SEE VENTING SHEET) ESB ZONE VALVE BALL VALVE LEGEND EXPANSION TANK SUPPLY AND RETURN MANIFOLD PRESSURE RELIEF VALVE HOSE BIB/DRAIN/ PURGE VALVE UNION CHECK VALVE - SPRING BACKFLOW PREVENTER AIR SEPARATOR TEMPERATURE GAUGE AIR VENT TEMPERATURE/ PRESSURE GAUGE PUMP W/ISOLATION FLANGES 3-WAY MOTORIZED MIXING VALVE THERMOSTATIC MIXING VALVE PUMP W/INTEGRAL FLOW CHECK PRESSURE REDUCING VALVE T T/P STRAINER M ZONE VALVE CONTROLLER TACO ZVC-404-EXP (MASTER)M O L EQUIPMENT IN MECHANICAL ROOM 1" 1-1/4" PIPING MECH. ROOM SIZED FOR COPPER TYP.EY[ZONE VALVE CONTROLLER TACO ZVC-404-EXP (SLAVE)N 7 MIXING VALVE WATTS N170 DHW RECIRC 5 DHW OUT COLD IN CITY COLD SUPPLY IN HOT WATER TO HOUSE FIXTURES 10 O F T GAS IN DRIP LEG G H P-1 E B 14 1" 10 7 TACO 008-F6 1/25 115/1 0.79 NA P-2 P1-P2 SUPPLY & RETURN MANIFOLD WATTS STAINLESS STEEL DHW EXPANSION TANK ELBI DXT-18 AIR ELIMINATOR TACO 4900 SERIES 49-100 EXPANSION TANK ELBI XT-30 ZONE VALVE TACO ZONE SENTRY Z100T2 M TACO ZVC ZONE CONTROL (ZONES 1-4) N TACO ZVC ZONE CONTROL (ZONES 5-7) 1"111° PIPING TO MANIFOLDS SIZED FOR PEX, TYP.1/2" MAKE-UP WATER C MINI SYSTEM FEEDER AXIOM MF200 10 9 TACO VT2218F NA 110/1 0.67 NA 3/4" 3/4" 3/4" 3/4"EY[K 3/4" 4 SUPPLY RETURN A MANIFOLD 4: ZONE 7 MANIFOLD 3: ZONES 5-6 SUPPLY RETURN A J655 MANIFOLD 1: ZONES 1-3 SUPPLY RETURN A J3332211 SUPPLY RETURN A MANIFOLD 2: ZONE 4 K ZONE VALVE TACO ZONE SENTRY Z075T2 REVISIONS:BY:VISOSORESIDENCE15358 SANTELLA COURTLOS GATOS, CA. 9503203/15/17MONTEREY ENERGY GROUPConsulting Mechanical Engineering26465 Carmel Rancho Blvd. Suite 8, Carmel, CA 93923831-372-8328 VOICE 831-359-4173 FAX www.montereyenergygroup.comcad@meg4.comPRELIMINARY - NOT FOR CONSTRUCTION OR BUILDING DEPARTMENT SUBMITTAL OR REVIEWTITLE TO THESE DRAWINGS AND SPECIFICATIONS REMAINS WITH THE ENGINEER WITHOUT PREJUDICE. VISUAL CONTACT WITH THESE DRAWINGS AND SPECIFICATIONS SHALL CONSTITUTE PRIMA FACIA EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.THE USE OF THESE DRAWINGS AND SPECIFICATIONS IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REPRODUCTION OR PUBLICATION BY ANY MEANS, IN WHOLE OR IN PART, IS PROHIBITED.MONTEREY ENERGY GROUP, INC.SHEET: CHECKED: FILE NAME: CHECKED: DRAWN: SCALE: DATE: REVISIONS:BY:CONTROLS SCHEMATICMEG M6.2 SHEET OF SHEETS AS NOTED FOUR ZONE VALVE CONTROL WITH OPTIONAL PRIORITY ZVC 404-EXP 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 T T T T T T T T1234 ZONE 4 RELAY N/O N/CCOM BOILER ENDSW A MODE NORMAL SLAVE MASTER POWER CONTROLS FUSE 7 AMP MAX EXPANSION PLUG-IN CARDS ON OFF PRIORITY ZONE 4 POWER INPUMP ENDSW B RESET FOUR ZONE VALVE CONTROL WITH OPTIONAL PRIORITY ZVC 404-EXP 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 T T T T T T T T1234 ZONE 4 RELAY N/O N/CCOM BOILER ENDSW A MODE NORMAL SLAVE MASTER POWER CONTROLS FUSE 7 AMP MAX EXPANSION PLUG-IN CARDS ON OFF PRIORITY ZONE 4 POWER INPUMP ENDSW B RESET EY[1 TYPICAL WIRING EXAMPLE FOR ZONE CONTROLLERS* NOT TO SCALE 24 VAC120 VAC INPUT WHITE BLACK BLACK WHITE INPUT 120 VAC TRANFORMERFACTORY INSTALLEDTRANFORMERINSTALLEDFACTORY 24 VAC 24 VAC FACTORY INSTALLEDTRANFORMERINSTALLEDFACTORY TRANFORMER120 VAC INPUT WHITE BLACK BLACK WHITE INPUT 120 VAC 24 VAC N H 120 VAC INPUT EQUIPMENT IN MECHANICAL ROOM RELABEL ZONES IN FIELD 6Ä6Ä6Ä6Ä 1 10 14 7 HEAT/COOL HEAT/COOL COMMUNICATION WIRING 7 COMMUNICATION WIRING MECHANICAL ROOM RADIANT LOOP FROM ZONE VALVE CONTROL ZONE VALVE CONTROL MASTER TO ADDITIONAL SLAVE ZVC UNIT(S) 8765 4432 DIP SWITCH TO "SLAVE" 6Ä6Ä6Ä6Ä #WVQ ( 57 *'#62/ 4*4%;9 )%V0 #WVQ ( 57 *'#62/ 4*4%;9 )%V0 #WVQ ( 57 *'#62/ 4*4%;9 )%V0 #WVQ ( 57 *'#62/ 4*4%;9 )%V0 #WVQ ( 57 *'#62/ 4*4%;9 )%V0 #WVQ ( 57 *'#62/ 4*4%;9 )%V0 #WVQ ( 57 *'#62/ 4*4%;9 )%V0 #WVQ ( 57 *'#62/ 4*4%;9 )%V0 TO WH-1 CONTROL BOARD (TSTAT CONTACTS) TO SYSTEM PUMP P-2 CONTROL BOARD *NOTE: THIS DETAIL IS A TYPICAL WIRING EXAMPLE AND DOES NOT REPRESENT THE EXACT WIRING CONFIGURATION PERTAINING TO THIS PROJECT. REFER TO PIPING SCHEMATIC FOR EXACT ZONE CONTROLLERS, THERMOSTATS AND ZONING REQUIRED. ZONE 5 ZONE 6 ZONE 7 ZONE 8 ZONE 5 ZONE 6 ZONE 7 ZONE 8 ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 1 ZONE 2 ZONE 3 ZONE 4 B3 SUPPLYRETURNVersa-Hydro P-2 S1 S2T 4 5 3 1 2 OffOn N H Req ReqComHtHtS1S2S3 00-VDT P-2 CONTROL BOARD N H 120 VAC INPUT 11 OUTDOOR SENSOR8OPTIONAL OUTDOOR SENSOR FOR VERSA-HYDRO OUTDOOR RESET CONTROL (OPTIONAL) EQUIPMENT IN MECHANICAL ROOM FROM ZVC SYSTEM PUMP END SWITCH FROM ZVC BOILER END SWITCH TO RADIANT MANIFOLDS. REFER TO TYPICAL ZONING DETAIL FOR WIRING 2 HEATING SYSTEM CONTROLS SCHEMATIC-Versa-Hydro COMBINATION HEATING AND DHW NOT TO SCALE N H ESB ZONE VALVE BALL VALVE 18 GAUGE RELAY/THERMOSTAT WIRE (2-8 CONDUCTOR) 120 V LEGEND EXPANSION TANK SUPPLY AND RETURN MANIFOLD PRESSURE RELIEF VALVE HOSE BIB/DRAIN/ PURGE VALVE UNION CHECK VALVE - SPRING BACKFLOW PREVENTER AIR SEPARATOR TEMPERATURE GAUGE AIR VENT TEMPERATURE/ PRESSURE GAUGE PUMP W/ISOLATION FLANGES 3-WAY MOTORIZED MIXING VALVE THERMOSTATIC MIXING VALVE PUMP W/INTEGRAL FLOW CHECK PRESSURE REDUCING VALVE T T/P EY[STRAINER M NOTES T/P P-1T REVISIONS:BY:VISOSORESIDENCE15358 SANTELLA COURTLOS GATOS, CA. 9503203/15/17MONTEREY ENERGY GROUPConsulting Mechanical Engineering26465 Carmel Rancho Blvd. Suite 8, Carmel, CA 93923831-372-8328 VOICE 831-359-4173 FAX www.montereyenergygroup.comcad@meg4.comPRELIMINARY - NOT FOR CONSTRUCTION OR BUILDING DEPARTMENT SUBMITTAL OR REVIEWTITLE TO THESE DRAWINGS AND SPECIFICATIONS REMAINS WITH THE ENGINEER WITHOUT PREJUDICE. VISUAL CONTACT WITH THESE DRAWINGS AND SPECIFICATIONS SHALL CONSTITUTE PRIMA FACIA EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.THE USE OF THESE DRAWINGS AND SPECIFICATIONS IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REPRODUCTION OR PUBLICATION BY ANY MEANS, IN WHOLE OR IN PART, IS PROHIBITED.MONTEREY ENERGY GROUP, INC.SHEET: CHECKED: FILE NAME: CHECKED: DRAWN: SCALE: DATE: REVISIONS:BY:PIPING SCHEMATICMEG M6.3 SHEET OF SHEETS AS NOTED 1 PIPING SCHEMATIC - AERMEC HEATING/COOLING ONLY NOT TO SCALE SYSTEM COMPONENTS NOTES MANUF. H G F C A MARK COMPONENT 12 NOTESMODEL E J SUPPLY & RETURN MANIFOLD -E.P. TEMP/PRESSURE GUAGE MILJOCO PB00804 TEMPERATURE GUAGE MILJOCO B259951-2W TELESTAT WATTS - MIXING VALVE WATTS N170 EQUIPMENT IN MECHANICAL ROOM PUMPS MODELMANUF.GPM FT HDMARK HP V/PH AMPS EFF. (%) MOTOR NOTES P-1a P1-P2 P1-P2 3/4" 1-1/2" MANUF. MODEL DIM. HT. X DIA. LBS FULL RECOV. AT 90° F RISE STORAGE TANK KBTUH IN GAL CAPMARK ST-1 30 --334 70-1/2"x14-1/4"BOILER BUDDY BB-30 B 6 FLOOR SINK B ST-1 RADIANT COOLING STORAGE M CONTROLS PER TEKMAR HP-1 OUTDOOR UNIT 14 1-1/4" 15 28 WILO STRATOS 1.25x3-30 1/4 230/1 0.16-1.37 NA 1-1/4" HW/ CW CON. WT LBSMARKHEATCOOL KBTUH ELECTRICAL COP MANUFACTURER AND MODEL NOTES AIR TO WATER HEAT PUMPS V/PH FLA H1-H3 E EXPANSION TANK ELBI XTV-30 PIPING TO MANIFOLDS SIZED FOR PEX, TYP. 1" 1" HP-1 60.0 46.0 230/1 30.3 1"407 2.11 SPACEPAK SCM-060A4 ESB ZONE VALVE BALL VALVE LEGEND EXPANSION TANK SUPPLY AND RETURN MANIFOLD PRESSURE RELIEF VALVE HOSE BIB/DRAIN/ PURGE VALVE UNION CHECK VALVE - SPRING BACKFLOW PREVENTER AIR SEPARATOR TEMPERATURE GAUGE AIR VENT TEMPERATURE/ PRESSURE GAUGE PUMP W/ISOLATION FLANGES 3-WAY MOTORIZED MIXING VALVE THERMOSTATIC MIXING VALVE PUMP W/INTEGRAL FLOW CHECK PRESSURE REDUCING VALVE STRAINER M P-1b P-2 HP-2 OUTDOOR UNIT 14 1-1/4"1-1/4" P-1a HP-2 60.0 46.0 230/1 30.3 1"407 2.11 SPACEPAK SCM-060A4 P-2 P-1b 15 28 WILO STRATOS 1.25x3-30 1/4 230/1 0.16-1.37 NA MANIFOLD 5: ZONES 1-4 SUPPLY RETURN A J4321 MANIFOLD 6: ZONES 5-7 SUPPLY RETURN A J77665 AH-1: HEAT RECOVERY VENTILATOR / DEHUMIFIER 1"1" 1-1/4" 1"1"1-1/4" 1-1/4"3/4"1-1/2"1-1/2" 0-52 0-34 TACO VR3452-FC1A00 1/100-1/4 115/1 2.5 NA AIR ELIMINATOR TACO 4900 SERIES 49-150 MINI SYSTEM FEEDER AXIOM MF200 1/2" MAKE-UP WATER C 1-1/4" H1-H3 REVISIONS:BY:VISOSORESIDENCE15358 SANTELLA COURTLOS GATOS, CA. 9503203/15/17MONTEREY ENERGY GROUPConsulting Mechanical Engineering26465 Carmel Rancho Blvd. Suite 8, Carmel, CA 93923831-372-8328 VOICE 831-359-4173 FAX www.montereyenergygroup.comcad@meg4.comPRELIMINARY - NOT FOR CONSTRUCTION OR BUILDING DEPARTMENT SUBMITTAL OR REVIEWTITLE TO THESE DRAWINGS AND SPECIFICATIONS REMAINS WITH THE ENGINEER WITHOUT PREJUDICE. VISUAL CONTACT WITH THESE DRAWINGS AND SPECIFICATIONS SHALL CONSTITUTE PRIMA FACIA EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS.THE USE OF THESE DRAWINGS AND SPECIFICATIONS IS RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED. PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. REPRODUCTION OR PUBLICATION BY ANY MEANS, IN WHOLE OR IN PART, IS PROHIBITED.MONTEREY ENERGY GROUP, INC.SHEET: CHECKED: FILE NAME: CHECKED: DRAWN: SCALE: DATE: REVISIONS:BY:DETAILSMEG M6.4 SHEET OF SHEETS AS NOTED BRACINGEXPANSION TANK 3 SCALE: NONE gpmgpmgpmgpmgpmgpmALTERNATE CONFIGURATION 2 SCALE: NONE INSTALLATIONMANIFOLD gpmgpmgpmgpm5060 70 800 10 2030 40 gpm70 80 5060 10 0 3020 40 4 MANIFOLD INSTALLATION-SINGLE ZONE MANIFOLD SCALE: NONE MULTI ZONE MANIFOLDgpmgpmgpmgpm503040 5060 70 800 10 2030 40 gpm6020 7010 800 SCALE: NONE1MANIFOLD INSTALLATION- SCALE: NONE Gypsum/Thin Slab Over Structrural SlabRADIANT APPLICATION-5 RADIANT APPLICATION-6 SCALE: NONE GYPSUM/THIN SLAB OVER WOOD FLOOR