Loading...
20102 Foster Rd - Staff Report and Exhibits 1-15PREPARED BY: ERIN WALTERS Associate Planner Reviewed by: Planning Manager and Community Development Director 110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874 www.losgatosca.gov TOWN OF LOS GATOS PLANNING COMMISSION REPORT MEETING DATE: 08/23/2017 ITEM NO: 4 DATE: AUGUST 18, 2017 TO: PLANNING COMMISSION FROM: JOEL PAULSON, COMMUNITY DEVELOPMENT DIRECTOR SUBJECT: ARCHITECTURE AND SITE APPLICATION S-14-122. PROJECT LOCATION: 20102 FOSTER ROAD. APPLICANT: TOM SLOAN, AIA. PROPERTY OWNER: SCOTT COKER. REQUESTING APPROVAL FOR CONSTRUCTION OF A SINGLE-FAMILY RESIDENCE AND AN ACCESSORY STRUCTURE ON VACANT PROPERTY ZONED HR-2½:PD. APN 537-33-009. DEEMED COMPLETE: AUGUST 8, 2017 FINAL DATE TO TAKE ACTION: FEBRUARY 8, 2018 RECOMMENDATION: Approval, subject to the recommended conditions of approval. PROJECT DATA: General Plan Designation: Hillside Residential Zoning Designation: HR-2½:PD, Single-Family Residential Applicable Plans & Standards: Hillside Specific Plan; Hillside Development Standards & Guidelines Parcel Size: 3.83 Acres Surrounding Area: Existing Land Use General Plan Land Use Designation Zoning North Residential Hillside Residential HR-5 South Residential Hillside Residential HR-2 ½ PD East Residential Hillside Residential HR-2 ½ PD West Open Space Open Space RC Prezone & RC PAGE 2 OF 10 SUBJECT: 20102 FOSTER ROAD/S-14-122 AUGUST 18, 2017 N:\DEV\PC REPORTS\2017\Foster Rd 20102 08.23.17.docx 8/18/2017 11:16 AM CEQA: The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. FINDINGS:  The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures.  As required by the Hillside Development Standards & Guidelines that other than the exception to the Least Restrictive Development Area, the project complies with the applicable sections of the Hillside Development Standards & Guidelines.  As required by the Hillside Specific Plan.  As required by Planned Development Ordinance 2088. CONSIDERATIONS:  As required by Section 29.20.150 of the Town Code for granting approval of an Architecture and Site application. ACTION: The decision of the Planning Commission is final unless appealed within ten days. BACKGROUND: On July 2, 2001, Town Council adopted Ordinance No. 2088 approving a Planned Development (PD) to demolish Guadalupe College for a six lot hillside residential subdivision, and the creation of a mutual water company (Exhibit 4). On November 5, 2002, the Planning Commission approved the subdivision in accordance with the performance standards set for th by the PD. Three homes have been approved and constructed in the subdivision. The property adjacent to the subject property, 20201 Foster Road, currently has a pending Architecture and Site Application for a new single-family home. On January 11, 2006, the Planning Commission approved an Architecture and Site application (S- 06-002) to construct a 5,113-square foot one story single-family residence, a 1,992-square foot cellar, a 810-square foot attached garage and a 444-square foot detached cabana on the subject site. The approved application included the relocation of the site’s Emergency Vehicle Access Easement (EVAE) to a similar location as the proposed project. PAGE 3 OF 10 SUBJECT: 20102 FOSTER ROAD/S-14-122 AUGUST 18, 2017 N:\DEV\PC REPORTS\2017\Foster Rd 20102 08.23.17.docx 8/18/2017 11:16 AM The Architecture and Site application was approved with the following exceptions:  A major height exception to exceed the 18-foot maximum height requirement for visible homes at one elevation that was not visible from the viewing platform to be 21-feet six inches tall;  An exception to construct a portion of the site’s driveway and retaining walls outside of the Least Restrictive Development Area (LRDA); and  An exception to allow a cut for the driveway greater than four feet. The property was then granted three 1-year time extensions for the approved 2006 Architecture and Site application. The application expired on January 11, 2011 because it was not vested. The proposed project is consistent with the PD for the site. The project is being considered by the Planning Commission, as required by the Hillside Development Standards and Guidelines (HDS&G), because the residence would exceed 5,000 square feet of floor area and the applicant has requested an exception to the LRDA pursuant to the HDS&G. PROJECT DESCRIPTION: A. Architecture and Site Application Architecture and Site approval is required to construct a new residence. B. Location and Surrounding Neighborhood The subject site is a vacant lot located approximately 180 feet northwest of the terminus of the cul-de-sac at the southern end of Foster Road (Exhibit 2). The lot is 3.83 acres with an average slope of 45.5 percent. On the southern portion of the lot there is an approximately 25,900- square foot non-vegetated, flat, graded pad. Densely vegetated slopes are located to the north and south of the flat graded pad. The project site is accessed from Foster Road. Single- family homes are located to the north, east, and south of the subject property. Midpeninsula Open Space District property, and a pre-zoned RC (Resource Conservation zone) property are located to the west of the subject property. C. Zoning Compliance A single-family residence is permitted in the HR-2½ zone. The proposed residence is in compliance with the allowable floor area for the property. Additionally, the proposed residence is in compliance with height, setback, and on-site parking requirements. PAGE 4 OF 10 SUBJECT: 20102 FOSTER ROAD/S-14-122 AUGUST 18, 2017 N:\DEV\PC REPORTS\2017\Foster Rd 20102 08.23.17.docx 8/18/2017 11:16 AM DISCUSSION: A. Architecture and Site Analysis The applicant is proposing to construct a one-story single-family home with 5,433 square feet of living floor area, 3,315 square feet of cellar area, and a 736-square foot attached garage. The maximum height of the proposed residence is 18 feet. The applicant is also proposing a 15-foot tall, 228-square foot accessory structure. The project proposes a Mediterranean style home with high quality materials including clay barrel tile roofing material, smooth stucco siding, stone walls, and metal accent railing. A color and materials sheet is included as Exhibit 11 and a color and materials board will be available at the public hearing. The applicant has designed the single-story house to be located on the existing flat graded pad, with a maximum height of 18 feet. All structures and improvements are located within the LRDA with the exception of a portion of the relocated Emergency Vehicle Access Easement (EVAE) (see EVAE/LRDA section below). Please see the applicant’s project description (Exhibit 5), letter of justification (Exhibit 6), and project data sheet (Exhibit 7) for additional information regarding the proposed project. B. Design and Compatibility The Town’s Architectural Consultant reviewed the project to provide recommendations regarding the architecture and neighborhood compatibility. The Consulting Architect noted that the proposal is very well designed, similar in scale to the current homes across Foster Road, and will fit well on the site. The Town’s Architectural Consultant reported that the proposed design is consistent with the Town’s Residential Design Guidelines and had no recommendations for changes (Exhibit 9). C. Grading/Geotechnical Review The proposed project meets the HDS&G grading standards and guidelines. The proposed residence, attached garage, accessory structure, swimming pool, retaining walls, driveway, relocated EVAE, and landscaping areas meet the HDS&G maximum cut and fill depths located in Table 1 on page 17 of the HDS&G. The applicant submitted geologic investigations that were peer reviewed by the Town’s Geotechnical Consultant. As noted above, the average slope of the lot is 45.5 percent. Although a majority of the site is sloped the proposed development area is located on a flat- graded pad. The investigations concluded that development of the site is feasible from a geologic and geotechnical engineering standpoint. Conditions of approval requiring PAGE 5 OF 10 SUBJECT: 20102 FOSTER ROAD/S-14-122 AUGUST 18, 2017 N:\DEV\PC REPORTS\2017\Foster Rd 20102 08.23.17.docx 8/18/2017 11:16 AM compliance with the geotechnical recommendations have been included in Conditions #62, 63 and 64 (Exhibit 3). D. Trees The project as reviewed by the Town’s Consulting Arborist and a report was prepared (Exhibit 10). The proposed project protects and retains all protected trees . Tree protection measures are incorporated in Exhibit 3 to protect trees remaining on the subject property. E. Visibility Pursuant to the HDS&G a visible home is defined as, a single-family residence where 25 percent or more of an elevation can be seen from any of the Town’s established viewing platforms. Based on the definition the proposed home is visible. When the subdivision was approved, it was understood that the proposed lots would be visible from the valley floor. Although visible, the proposed house will have significantly less visual impact than the structures that previously existed on the subdivision site (Guadalupe College). Pursuant to the requirements of the View Analysis section on page 13 of the HDS&G, the applicant installed story poles on site that identify the proposed building envelope. The applicant took photographs of the story poles from the established viewing platforms that show the story poles and subject property. Photographs from the viewing platforms were taken with a 50 MM and 300 MM lens (Exhibit 12). The applicant has provided photos showing the following: a. Proposed story poles with existing trees to remain; b. Proposed story poles without existing trees to remain; and c. Photo simulations of the proposed single family residence. The visibility analysis determined that 29.94 percent of the right elevation and 22.51 percent of the front elevation of the proposed single-family residence are visible from the Blossom Hill Road/Los Gatos Boulevard platform. 29.62 percent of the residence is visible from the Highway 17 overcrossing/Los Gatos- Saratoga Road (Highway 9) platform. The existing trees that have been identified in the photographs as providing screening for portions of the proposed single family residence are rated in good condition and will remain. Pursuant to Standard 3 of the Building Height section of the HDS&G, the visual impact of visible homes shall be mitigated to the greatest extent reasonable by reducing the height of the home. The proposed height of the visible home would not exceed 18 feet, which complies with the maximum height allowed for visible homes. PAGE 6 OF 10 SUBJECT: 20102 FOSTER ROAD/S-14-122 AUGUST 18, 2017 N:\DEV\PC REPORTS\2017\Foster Rd 20102 08.23.17.docx 8/18/2017 11:16 AM Staff is in the process of providing a modified visibility methodology for the Council to consider and incorporate into an upcoming amendment to the HDS&G. The applicant’s methodology complies with the current methodology. F. Emergency Vehicle Access Easement (EVAE) and Least Restrictive Development Area (LRDA) The subject site includes an existing 20-foot wide Emergency Vehicle Access Easement (EVAE) as required by the PD ordinance for this property (Exhibit 4). The EVAE provides emergency vehicle access from Foster Road across the subject site to the Midpeninsula Regional Open Space District (Midpen) property (St. Joseph’s Hill Open Space Preserve), located to the west of the site (Exhibit 15, Sheet C-8.0). This EVAE is not for public access. There is a gate located at the terminus of the EVAE road on the adjacent Midpen property that is for emergency vehicle access only. There is no public access through this gate. The applicant has pos ted a “No Trespassing” sign on the vacant property to detour the public from trespassing across the applicant’s property, via the EVAE to access the Midpen property. Staff has confirmed with Midpen that this gate is not for public access to St. Joseph’s Hill Open Space Preserve and the EVAE is for emergency vehicle access only. Public access to St. Joseph’s Hill is provided from the Los Gatos Creek Trail, the Jones Trail, and Novitiate Park. St. Joseph’s Hill can be also accessed from the Santa Clara County Lexington Reservoir Park as described on the Midpeninsula Regional Open Space District website, https://www.openspace.org/. The applicant is requesting to relocate the 20-foot wide EVAE in order to provide a more natural appearance to the site by eliminating the un-natural existing contour previously created for the EVAE. The applicant would also like to relocate and redesign the EVAE layout to meet the 20-foot width requirement and required turning radius. The current layout is larger than the required 20-feet, utilizing more of the applicant’s useable property than necessary. The proposed relocation of the EVAE will result in a 12-foot wide portion of the road being located out of the LRDA. The applicant has provided a letter of justification for the proposed relocation of the EVAE (Exhibit 6). The slope adjacent to the existing EVAE is not a natural slope and is an engineered slope resulting from the demolition of Guadalupe College. The existing EVAE is located adjacent to a steep graded transition down the hill. When the site pad and EVAE were graded for the subdivision, the EVAE was built up on a raised unnatural grade at the northern edge of the flat pad. The proposed relocated EVAE would meet the HDS&G standards with the exception of the 12- foot wide portion of the road that will be located outside of the LRDA. The proposal would meet the PD performance standards. The Town’s Parks and Public Works Engineering Division, the Santa Clara County Fire Department, and Midpen have reviewed the proposal and find that PAGE 7 OF 10 SUBJECT: 20102 FOSTER ROAD/S-14-122 AUGUST 18, 2017 N:\DEV\PC REPORTS\2017\Foster Rd 20102 08.23.17.docx 8/18/2017 11:16 AM the proposal meets the standards and requirements as specified in Conditions of Approval #61, 83, 84, 106 of Exhibit 3. Staff concurs with the applicant that the exception would serve to reduce the unnatural transition between the graded pad and abrupt slope and streamline the layout of the EVAE to meet the PD performance standards and the Santa Clara County Fire Department standards. The proposal is consistent with the overall intent of the HDS&G. The HDS&G identify exceptions for height and maximum floor area as major exceptions. A n exception would need to be granted to allow the proposed site work outside the LRDA, however, it would not be a major exception. G. Neighborhood Compatibility The immediate neighborhood is made up of one and two-story residences and includes a mix of architectural styles. Based on Town and County records, the surrounding residences range in size from 1,425 square feet to 8,347 square feet. The floor area ratios (FAR) range from 0.01 FAR to 0.15 FAR. The applicant is proposing a residence of 5,433 square feet on a 166,815- square foot parcel (0.03 FAR). Pursuant to the HDS&G, the maximum house square footage for the lot size is 6,000 square feet. The following Neighborhood Analysis table reflects current conditions of the immediate neighborhood: ADDRESS House Garage Gross Lot Area House FAR Stories 17980 Foster Rd. 1,425 500 9,750 0.15 2 800 Foster Rd. 2,552 240 83,200 0.03 2 17850 Foster Rd. 4,053 1,153 31,150 0.13 3 17986 Foster Rd. 6,975 750 473,192 0.01 1 20101 Foster Rd. 0 0 111,513 n/a Pending - S-16-074 20103 Foster Rd. 4,899 1,066 45,738 0.11 1 20108 Foster Rd. 8,347 1,577 338,897 0.02 2 20102 Foster Rd. (N) 5,433 737 166,835 0.03 1 20102 Foster Rd. (E) 0 0 166,835 0 0 PAGE 8 OF 10 SUBJECT: 20102 FOSTER ROAD/S-14-122 AUGUST 18, 2017 N:\DEV\PC REPORTS\2017\Foster Rd 20102 08.23.17.docx 8/18/2017 11:16 AM The proposed residence would be the third largest home in the immediate area in terms of square footage and the fourth largest in terms of FAR. H. Environmental Review The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. PUBLIC COMMENTS: Story poles and signage were installed on the site and written notice was sent to property owners and tenants within 500 feet of the subject property. The applicant has informed staff that they have discussed the project with their adjacent neighbors, who expressed no objections. The applicant has provided two signed letters from the immediate neighbors supporting the project (Exhibit 13). At the time of this report’s preparation, the Town has not received any public comment. Exhibit 14 includes public comments received by 11:00 a.m., Friday August 18, 2 017. CONCLUSION: A. Summary The proposed project would allow the applicant to construct a one-story single-family residence on a vacant lot. As proposed, the project would create a 5,433-square foot residence with a 3,315-square foot cellar, 736-square foot attached garage, and a 228-square foot accessory structure. The applicant has submitted a letter of justification (Exhibit 6) to explain how the project is consistent with the General Plan, Hillside Specific Plan, and HDS&G. As discussed earlier in this report, the applicant is requesting an exception to construct a portion of the relocated EVAE outside the LRDA. As stated above, staff believes that the plans have been designed to meet the intent of the HDS&G and the exception is justified. PAGE 9 OF 10 SUBJECT: 20102 FOSTER ROAD/S-14-122 AUGUST 18, 2017 N:\DEV\PC REPORTS\2017\Foster Rd 20102 08.23.17.docx 8/18/2017 11:16 AM B. Recommendation Based on the analysis above, staff recommends approval of the Architecture and Site application subject to the recommended conditions of approval (Exhibit 3). If the Planning Commission finds merit with the proposed project, it should: 1. Find that the proposed project is Categorically Exempt, pursuant to the adopted Guidelines for the implementation of the California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures (Exhibit 2); 2. Make the finding that the exception to the Least Restrictive Development Area is appropriate and the project is otherwise in compliance with the applicable sections of the Hillside Development Standards and Guidelines (Exhibit 2); 3. Make the finding that the project is in compliance with the Hillside Specific Plan (Exhibit 2); 4. Make the finding that the project is in compliance with the Planned Development (Ordinance 2088) (Exhibit 2); 5. Make the required considerations as required by Section 29.20.150 of the Town Code for granting approval of an Architecture & Site application (Exhibit 2); and 6. Approve Architecture & Site Application S-14-122 with the conditions contained in Exhibit 3 and the development plans in Exhibit 15. C. Alternatives Alternatively, the Commission can: 1. Continue the matter to a date certain with specific direction; or 2. Approve the application with additional and/or modified conditions; or 3. Deny the application. EXHIBITS: 1. Location Map 2. Required Findings and Considerations (one page) 3. Recommended Conditions of Approval (15 pages) 4. Planned Development Ordinance 2088 (Exhibits A and B are excluded) (12 pages) 5. Project Description, received May 30, 2017 (one page) 6. Letter of Justification, received July 25, 2017 (two pages) 7. Project Data Sheet (two pages) 8. Hillside Standards and Guidelines: Compliance Checklist, received March 23, 2017 (nine pages) 9. Consulting Architect’s Report, received August 29, 2016 (four pages) 10. Consulting Arborist’s Report, dated January 8, 2016 (31 pages) 11. Color and Material Sheet, received July 24, 2017 (two pages) 12. Visibility Study, received August 7, 2017 (11 pages) PAGE 10 OF 10 SUBJECT: 20102 FOSTER ROAD/S-14-122 AUGUST 18, 2017 N:\DEV\PC REPORTS\2017\Foster Rd 20102 08.23.17.docx 8/18/2017 11:16 AM 13. Neighborhood Outreach, received April 2, 2017 (two pages) 14. Public comments received by 11:00 a.m., Friday, August 18, 2017 15. Development Plans, received July 20, 2017 (22 sheets) Distribution: Scott Coker, 1942 Coastland Avenue, San Jose, CA 95125 Tom Sloan, AIA, 1475 S. Bascom Avenue, Suite 208, Campbell, CA 95008 20102 Foster Road EXHIBIT 1 This Page Intentionally Left Blank PLANNING COMMISSION -August 23, 2017 REQUIRED FINDINGS & CONSIDERATIONS FOR: 20102 Foster Road Architecture and Site Application S-14-122 Requesting approval of a grading permit, construction of a single-family residence and an accessory structure on vacant property zoned HR-21h:PD. APN 537-33-009. PROPERTY OWNER: Scott Coker APPLICANT: Tom Sloan, AIA FINDINGS Required findings for CEQA: • The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation ofthe California Environmental Quality Act, Section 15303: New Construction or Conversion of Small Structures. Compliance with Hillside Development Standards and Guldellnes (HDS&G): • As required by the HDS&G that other than the exception to the Least Restrictive Development Area, the project complies with the HDs&G . Compliance with Hiiiside Specific Plan • The project is in compliance with the Hillside Specific Plan in that it is a single-family residence being developed on an existing parcel. The proposed development is consistent with the development criteria included in the Specific Plan. Compliance with the approved Planned Development • The project is in compliance with the approved Planned Development (Ordinance 2088). CONSIDERATIONS: Considerations In review of Architecture & Site applications: • As required by Section 29 .20.150 of the Town Code, the considerations in review of an Architecture and Site application were all made In reviewing this project. N:\DEV\FINDINGS\2017\Foster20102 8.23.17 .doc EXHIBIT 2 This Page Intentionally Left Blank PLANNING COMMISSION-August 23, 2017 CONDITIONS OF APPROVAL 20102 Foster Road Architecture and Site Application S-14-122 Requesting approval of a grading permit, construction of a single-family residence and an accessory structure on vacant property zoned HR-211.i:PD. APN 537-33-009. PROPERTY OWNER: Scott Coker APPLICANT: Tom Sloan, AIA TO THE SATISFACTION OF THE DIRECTOR OF COMMUNITY DEVELOPMENT: Planning Division 1. APPROVAL: This application shall be completed in accordance with all of the conditions of approval and in substantial compliance with the approved p lans. Any changes or modifications to the approved plans and/or business operation shall be approved by t~e Community Development Director, DRC or the Planning Commission depending on the scope of the changes. 2. EXPIRATION : The approval will expire two years from the approval date pursuant to Section 29.20.320 of the Town Code, unless the approval has been vested. 3. OUTDOOR LIGHTING : Exterior lighting shall be kept to a minimum, and shall be down di rected fixtures that will not reflect or encroach onto adjacent properties ~ No flood lights shall be used unless It can be demonstrated that they are needed for safety or security. 4. TREE REMOVAL PERMIT: A Tree Removal Permit shall be obtai ned for any trees to be removed, p ri or to the issuance of a building or grad i ng permit. 5. EXISTING TREES: All existing trees shown on the plan and trees required to remain or to be planted are specific subjects of approval of this plan, and must remain on the site. 6. TREE FENCING: Protective tree fencing and other protection measures shall be placed at t he drip line of existing trees prior to issuance of demolition and build ing permits and shall remain through all phases of construction . Include a tree protection plan with the construction plans. 7. TREE STAKING : All newly planted trees shall be double-staked using rubber tree ties. 8. FRONT YARD LANDSCAPE : Prior to issuance of a Certificate of Occupancy the front yard must be landscaped. 9. ARBORIST REQUIREMENTS: The developer shall Implement, at their cost, all recommendations identified in the Arborist's report dated as received January 13, 2016 for the project, on file in the Community Development Department. These recommendations must be incorporated i n the building permit plans, and completed prior to issuance of a building permit where applicable. 10. LANDSCAPE PLAN: The final landscape plan shall comply w ith the Hillside Development Standards and Guidelines criteria for landscape design. :EXHIBIT 3 11. WATER EFFECIENCY LANDSCAPE ORDINANCE: The final landscape plan shall meet the Town of Los Gatos Water Conservation Ordinance or the State Water Efficient Landscape Ordinance, whichever is more restrictive. A review fee based on the current fee schedule adopted by the Town Council is required when working landscape and irrigation plans are submitted for review. 12. GREEN BUILDING: The house shall be designed to achieve compliance with GreenPoint Rated Standards for green building certification. The GreenPoint checklist shall be completed by a Certified Green Building Professional and submitted to the Town prior to issuance of a building permit. 13. STORY POLES: The story poles on the project site shall be removed within 30 days of approval of the Architecture & Site application. 14. EXTERIOR COLORS: The exterior colors of all structures shall comply with the Hillsi de Development Standards & Guidelines. 15. DEED RESTRICTION: Pri or to the issuance of a building permit, a deed restriction shall be recorded by the applicant with the Santa Clara County Recorder's Office that requires all exterior materials be maintained in conformance with the Town's Hillside Development Standards & Guidelines. 16. BMP FEES: An in-lieu fee of building a Below Market Price unit shall be paid. The fee shall be equal to six percent of the Building permit valuation which shall be determined by the Director of Community Development. The fee shall be paid prior to final occupancy. 17. SOLAR: During the Architecture and Site application process all new residences, to the extent feasible, shall be designed to take full advantage of passive solar opportunities. Each residence shall be pre-plumbed for solar hot water heating and shall comply with the Town's Conservation Element of the General Plan . 18. *RED RIBBONS : Prior to issuance of a building permit, a survey for Santa Clara red ribbons shall be conducted at the developer's expense to determine the presence or absence of home sites located in undeveloped areas (Lots 4 through 6) including all areas where disturbance could occur as part of home construction. This survey shall also include any areas along the final haul road alignment that deviate from the July 1999 alignment that was already surveyed. Any areas found to be supporting this species should be avoided and if avoidance is infeasible, a mitigation and monitoring plan detailing the location and acreage of off-site m it igation should be developed based on consultation with the appropriate agency. 19. *NESTING SEASON: If any construction activities occur during the nesting season (February to August), these activities shall be preceded by pre-construction surveys for nesting raptors by a qualified ornithologist at the developer's expense. Surveys shall be conducted no more than 30 days prior to the start of construction . No construction activities (including tree removal, grading, etc) that would result in disturbance to active raptor nest shall be allowed to proceed. A qualified ornithologist shall determine the extent of construction-free zones around active raptor nests located during surveys. The USFWS and CDFG shall also be modified of any active raptor nests within the construction zone. 20. TOWN INDEMNllY: Applicants are notified that Town Code Section 1.10.115 requires that any applicant who receives a permit or entitlement from the Town shall defend, indemnify, and hold harmless the Town and its officials in any action brought by a third party to overturn, set aside, or void the permit or entitlement. This requirement is a condition of approval o'f ali such permits and entitlements whether or not expressly set forth in the approval, and may be secured to the satisfaction of th~ Town Attorney. 21. COMPLIANCE MEMORANDUM: A memorandum, in compliance with standard Town practice, shall be prepared and submitted with the building permit detailing how the conditions of approval will be addressed. TO THE SATISFACTION OF THE DIRECTOR OF COMMUNITY DEVELOPMENT: Building Division 22. PERMITS REQUIRED: A Building Permit shall be requited for the construction of the new single-family residence with cellar, attached garage and accessory structure. A separate Building Permit for the swimming pool and a separate Building Permit for site retaining walls not connected to the residence are required. Separate permits are required for electrical, mechanical, and plumbing work as necessary. 23. CONDITIONS OF APPROVAL: The Conditions of Approval must be blue-lined in full on the cover sheet of the construction plans. A Compliance Memorandum shall be prepared and submitted with the building permit application detailing how the Conditions of Approval will be addressed. 24. SIZE OF PLANS: Submit four sets of construction plans, minimum size 24" x 36", maximum size 30" x 42". 25. SOILS REPORT: A Soils Report, prepared to the satisfaction of the Building Official, containing foundation and retaining wall design recommendations, shall be submitted with the Building Permit Application. This report shall be prepared by a licensed Civil Engineer specializing in soils mechanics. 26. SHORING : Shoring plans and calculations will be required for all excavations which exceed five (5) feet in depth or which remove lateral support from any existing building, adjacent property, or the public right-of-way. Shoring plans and calculations shall be prepared by a California licensed engineer and shall confirm to the Cal/OSHA regulations. 27 . FOUNDATION INSPECTIONS: A pad certificate prepared by a licensed civil engineer or land surveyor shall be submitted to the project Building Inspector at foundation inspection. This certificate shall certify compliance with the recommendations as specified in the Soils Report, and that the building pad elevations and on-site retaining wall locations and elevations have been prepared according to the approved plans. Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered Civil Engineer for the following items: a. Building pad elevation b . Finish floor elevation c. Foundation comer locations d. Retaining wall(s) locations and elevations 28. TITLE 24 ENERGY COMPLIANCE: All required California Title 24 Energy Compliance Forms must be blue-lined (sticky-backed), i.e. directly printed~ onto a plan sheet. 29. TOWN RESIDENTIAL ACCESSIBILITY STANDARDS: New residential units shall be designed with adaptability features for single-family residences per Town Resolution 1994-61: a. Wood backing (2" x 8" mi nimum) shall be provided in all bathroom walls, at water closets, showers, and bathtubs, located 34 inches from the floor to the center of the backing, suitable for the installation of grab bars if needed in the future. b . All passage doors shall be at least 32 inch doors on the accessible floor level. c. The primary entrance door shall be a 36 inch wide door including a 5'x 5' level landing, no more than 1 inch out of plane with the Immediate interi or floor level and with an 18 inch clearance at interior strike edge. d . A door buzzer, bell or chime shall be hard wired at primary entrance. 30. BACKWATER VALVE: The scope of this project may require the i nstallation of a sanitary sewer backwater valve per Town Ordinance 6.50.025. Plea se provide information on the plans if a backwater valv e is required and the location of the installation. The Town of Los Gatos Ordinance and West Valley Sanitati on District (WVSD) requires backwater valves on drainage piping serving fixtures that have flood level rims less than 12 inches above the elevation of the next upstream manhole. 31. TOWN FIREPLACE STANDARDS: New wood burning fireplaces shall be an EPA Phase II appliance or gas appliance as per Town Ordinance 1905. Tree limbs shall be cut within 10 feet of chimneys. 32. HAZARDOUS FIRE ZONE: This project will require Class A Roof Assemblies. 33. WILDLAND-URBAN INTERFACE: This project is located in a Wildland-Urban Interface High Fi re Area and must comply with Section R327 of the 2013 California Public Resources Code 4291 and California Government Code Section 51182. 34. PROVIDE DEFENSIBLE SPACE/FIRE BREAK LANDSCAPING PLAN : Pr epared by a California licensed Landscape A rchitect in conformance with Californ i a Public Resources Code 4291 and California Government Code Section 51182. 35. PRIOR TO FINAL INSPECTION: Provide a letter from a California licensed Landscape Architect certifying the landscaping and vegetation clearance requirements have been completed per the Californ ia Public Resources Code 4291 and Government Code Section 5 118 2. 36. SPECIAL INSPECTIONS: When a special inspection is required by CBC Section 1704, the Architect or Engineer of Record shall prepare an inspection program that shall be subm itted to the Building Official for approval prior to issuance of the Building Permit. The Town Special Inspection form must be completely filled-out and signed by all requested parties prior to permit issuance. Special Inspection forms are available from the Bu i ld i ng Divisi on Service Counter or online at www.losgatosca.gov/building. 37. BLUE PRINT FOR A CLEAN BAY SHEET : The Town standard Santa Clara Valley Nonpoint Sou rce Pollution Control Program Sheet (24"x36") shall be part of the plan submittal as the second page. The specification sheet is available at the Building Division Service Counter for a fee of $2 or at ARC Blue Print for a fee or on line at www.losgatosca.gov/building. 38. APPROVALS REQUIRED: The project requir es the following departments and agencies approval before issuing a building permit: a. Community Development -Planning Division: Erin Walt ers (408) 354-6 86 7 b. Engineering/Parks & Public Works Department: Mike Weisz (408) 354-5236 c. Santa Clara County Fire Department: (408) 378-4010 d. West Valley Sanitation District: (408) 378-2407 e. Local School District: The Town will forward the paperwork to the appropriate school dlstrict(s) for processing. A copy of the paid receipt Is required prior to permit issuance. TO THE SATISFACTION OF THE DIRECTOR OF PARKS AND PUBLIC WORKS: Engineering Division 39. GENERAL: All public improvements shall be made according to the latest adopted Town Standard Plans, Standard Specifications and Engineering Design Standards. All work shall conform to the applicable Town ordinances . The adjacent public right-of-way shall be kept clear of all job-related dirt and debris at the end of the day. Dirt and debris shall not be washed into storm drainage facilities. The storing of goods and materials on the sidewalk and/or the street will not be allowed unless an encroachment permit is issued. The Developer's representative in charge shall be at the job site during all working hours. Failure to maintain the public right-of-way according to this condition may result In the Town performing the required maintenance at the Developer's expense. 40. APPROVAL: This application shall be completed in accordance with all of the conditions of approval listed below and in substantial compliance with the latest reviewed and approved development plans. Any changes or modifications to the approved plans or conditions of approvals shall be approved by the Town Engineer. 41. ENCROACHMENT PERMIT: All work in the public right-of-way will require a Construction Encroachment Permit. All work over $5,000 will require construction security. It is the responsibility of the Applicant/Developer to obtain any necessary encroachment permits from affected agencies and private parties, including but not limited to, Pacific Gas and Electric (PG&E), AT&T, Comcast, Santa Clara Valley Water District, California Department of Transportation (Caltrans). Copies of any approvals or permits must be submitted to the Town Engineering Division of the Parks and Public Works Department prior to releasing any permit. 42. PRIVATE IMPROVEMENTS IN THE PUBLIC RIGHT-OF-WAY {INDEMNITY AGREEMENT): The property owner shall enter into an agreement with the Town for all existing and proposed private improvements within the Town's right-of-way. The Owner shall be solely responsible for maintaining the improvements in a good and safe condition at all times and shall indemnify the Town of Los Gatos. The agreement must be completed and accepted by the Director of Parks and Public Works, and subsequently recorded by the Town Clerk at the Santa Clara County Office of the Clerk-Recorder, prior to the issuance of any permits. Please note that this process may take approximately four (4) weeks. 43. PUBLIC WORKS INSPECTIONS: The Developer or their representative shall notify the Engineering Inspector at least twenty-four (24) hours before starting any work pertaining to on-site drainage facilities, grading or paving, and all work in the Town's right-of-way. Failure to do so will result in penalties and rejection of work that went on without inspection. 44. RESTORATION OF PUBLIC IMPROVEMENTS: The Developer shall repair or replace all existing improvements not designated for removal that are damaged or removed because of the Developer's operations. Improvements such as, but not limited to: curbs, gutters, sidewalks, driveways, signs, pavements, raised pavement markers, thermoplastic pavement markings, etc., shall be repaired and replaced to a condition equal to or better than the original condition . Any new concrete shall be free of stamps, logos, names, graffiti, etc. Any concrete identified that is displaying a stamp or equal shall be removed and replaced at the Contractor's sole expense and no additional compensation shall be allowed therefore. Existing improvement to be repaired or replaced shall be at the direction of the Engineering Construction Inspector, and shall comply with all Title 24 Disabled Access provisions. The Developer shall request a walk-through with the Engineering Construction Inspector before the start of construction to verify existing conditions. 45. SITE SUPERVISION: The General Contractor shall provide qualified supervision on the job site at all times during construction. 46. STREET CLOSURE: Any proposed blockage or partial closure of the street requires an encroachment permit. Special provisions such as limitations on works hours, protective enclosures, or other means to facilitate public access in a safe manner may be required. 47. PLAN CHECK FEES : Plan check fees shall be deposited with the Town prior to plan review at the Engineering Division of the Parks and Public Works Department. 48. INSPECTION FEES: Inspection fees shall be deposited with the Town prior to the issuance of any permits or recordation of the Parcel I Final Map. 49. DESIGN CHANGES : Any proposed changes to the approved plans shall be subject to the approval of the Town prior to the commencement of any and all altered work. The Applicant's project engineer shall notify, in writing, the Town Engineer at least seventy- two (72) hours in advance of all the proposed changes. Any approved changes shall be incorporated into the final "as-built" plans. 50. GATE: New gate(s) providing access from a road to a driveway shall be located at least 25 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on the road. Where a one-way road with a single traffic lane provides access to a gate entrance, a 38 foot turning radius shall be used. Gate(s) shall be automatic or manual operated, a minimum of 24 feet in width, with a setback of 25 feet from face of curb/flow line. Gate access shall be equipped with a rapid entry system. Plans shall be submitted to the Santa Clara County Fire Department for approval prior to installation. Automatic/manual gate pins shall be rated with shear pin force, not to exceed 30 foot pounds. Automatic gates shall be equipped with emergency backup power. Gates activated by the rapid entry system shall remain open until closed by the rapid entry system. 51. PLANS AND STUDIES : All required plans and studies shall be prepared by a Registered Professional Engineer in the State of California, and submitted to the Town Engineer for review and approval. Additionally, any studies imposed by the Planning Commission or Town Council shall be funded by the Applicant. 52. GRADING PERMIT: A grading permit is required for all site grading and drainage work except for exemptions listed in Section 12.20.015 of The Code of the Town of Los Gatos (Grading Ordinance). The grading permit application (with grading plans) shall be made to the Engineering Division ofthe Parks and Public Works Department located at 41 Miles Avenue. The grading plans shall include final grading, drainage, retaining wall location(s), driveway, utilities, and interim erosion control. Grading plans shall list earthwork quantities and a table of existing and proposed impervious areas. Unless specifically allowed by the Director of Parks and Public Works, the grading permit will be issued concurrently with the building permit. The grading permit Is for work outside the building footprlnt(s). Prior to Engineering signing off and closing 01.Jt on the issued grading permit, the Owner/Applicant's soils engineer shall verify, with a stamped and signed letter, that the grading activities were completed per plans and per the requirements as noted in the soils report. A separate building permit, issued by the Building Department on E. Main Street, is needed for grading within the building footprint. 53. GRADING ACTIVITY RESTRICTIONS: Upon receipt of a grading permit, any and all grading activities and operations shall not commence until after the rainy season, as defined by the State Water Resources Control Board (October 1-April 30), has ended. 54. COMPLIANCE WITH HILLSIDE DEVELOPMENT STANDARDS AND GUIDELINES: All grading activities and operations shall be in compliance with Section Ill of the Town's Hillside Development Standards and Guidelines. All development shall be In compliance with Section II of the Town's Hillside Development Standards and Guidelines. 55. DRIVEWAY: The driveway conform to existing pavement on Foster Road shall be . constructed in a manner such that the existing drainage patterns will not be obstructed. 56. DRAINAGE STUDY: Prior to the issuance of any grading permits, the following drainage studies, stamped and signed letter from the responsible engineer in charge, shall be submitted to and approved by the Town Engineer: a drainage study of the project including diversions, off-site areas that drain onto and/or through the project, and justification of any diversions; and a drainage study evidencing that the proposed drainage patterns will not overload the existing storm drain facilities. 57. DRAINAGE IMPROVEMENT: Prior to the issuance of any grading/improvement permits, whichever comes first, the Applicant shall : a. design provisions for surface drainage; and b. design all necessary storm drain facilities extending to a satisfactory point of disposal for the proper control and disposal of storm runoff; and c. provide a recorded copy of any required easements to the Town. 58. SURVEYING CONTROLS: Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered civil engineer qualified to practice land surveying, for the following items: a. Retaining wall: top of wall elevations and locations. b. Toe and top of cut and fill slopes. 59. RETAINING WALLS: A building permit, issued by the Building Department at 110 E. Main Street, may be required for site retaining walls. Walls are not reviewed or approved by the Engineering Division of Parks and Public Works during the grading permit plan review process. 60. WEST VALLEY SANITATION DISTRICT : All sewer connection and treatment plant capacity fees shall be paid immediately prior to the issuance of a sewer connection permit. Written confirmation of payment of these fees shall be provided prior to map recordation. 61 . DEDICATIONS: The following shall be dedicated by separate instrument. The dedication shall be recorded before any permits are issued: a) Emergency Vehicle Access Easement, Storm Drain Easement & Private Sanitary Sewer Easement (E .V.A.E., S.D.E. & P.S.S.E.): Twenty (20) feet wide, through the property In question stretching from the western right-of-way line of Foster Road to property's western boundary. The easement shall envelope the existing sanitary sewer and storm drain facilities that run along this portion of the property. The location, alignment, and layout of the proposed E.V.A.E. shall be approved by the Santa Clara County Fire Department and Midpeninsula Regional Open Space District prior to recordation. 62. SOILS REPORT: One copy of the soils and geologic report shall be submitted with the application. The soils report shall Include specific criteria and standards governing site grading, drainage, pavement design, retaining wall design, and erosion control. The reports shall be signed and "wet stamped" by the engineer or geologist, in conformance with Section 6735 of the California Business and Professions Code. 63. GEOLOGY AND SOILS MITIGATION MEASURE: A geotechn ical investigation shall be conducted for the project to determine the surface and sub-surface conditions at the site and to determine the potential for surface fault rupture on the site. The geotechnical study shall provide recommendations for site grading as well as the design of foundations, retaining walls, concrete slab-on-grade corstruction, excavation, drainage, on-site utility trenching and pavement sections. All recommendations of the investigation shall be incorporated into project plans. 64. SOILS REVIEW: Prior to issuance of any permits, the Applicant's engineers shall prepare and submit a design-level geotechnlcal and geological investigation for review and approval by the Town. The Applicant's soils engineer shall review the final grading and drainage plans to ensure that designs for foundations, retaining walls, site grading, and site drainage are in accordance with their recommendations and the peer review comments. Approval of the Applicant's soils engineer shall then be conveyed to the Town either by submitting a Plan Review Letter prior to issuance of building permit(s}. 65. SOILS ENGINEER CONSTRUCTION OBSERVATION: During construction, all excavations and grading shall be inspected by the Applicant's soils engineer prior to placement of concrete and/or backfill so they can verify that the actual conditions are as anticipated in the design-level geotechnical report, and recommend appropriate changes in the recommendations contained in the report, if necessary. The results of the construction observation and testing shall be documented in an "as-built" letter/report prepared by the Applicant's soils engineer and submitted to the Town before final release of any occupancy permit is granted. 66. SOIL RECOMMENDATIONS: The project shall incorporate the geotechnical/geological recommendations contained in the project's design-level geotechnical/geological investigation as prepared by the Applicant's engineer(s), and any subsequently required report or addendum . Subsequent reports or addendum are subject to peer review by the Town's consultant and costs shall be borne by the Applicant. 67. WATER DESIGN: Water plans prepared by San Jose Water Company must be reviewed and approved prior to issuance of any permit. 68. WATER METER: The existing water meter, currently located within the Foster Road right- of-way, shall be relocated within the property in question, directly behind the public right- of-way line. The Applicant shall repair and replace to existing Town standards any portion of concrete flatwork within said right-of-way that is damaged during this activity. 69. FRONTAGE IMPROVEMENTS: The Applicant shall be required to improve the project's public frontage to current Town Standards. These improvements may include but not limited to curb, gutter, etc. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. 70. UTILITIES: The Applicant shall install all new, relocated, or temporarily removed utility services, including telephone, electric power and all other communications lines underground, as required by Town Code Section 27.50.0lS(b). All new utility services shall be placed underground. Underground conduit shall be provided for cable television service. The Applicant Is required to obtain approval of all proposed utility alignments from any and all utility service providers before a Certificate of Occupancy for any new building can be issued. The Town of Los Gatos does not approve ·or imply approval for final alignment or des ign of these faciHtles. 71 . UTILITY SETBACKS: House foundations shall be set back from utility lines a sufficient distance to allow excavation ·of the utility without undermining the house foundation. The Town Engineer shall determine the appropriate setback based on the depth of the utility, input from the project soils engineer, and the type of foundation. 72. UTILITY EASEMENTS: Deed restrictions shall be placed on lots containing utility easements . The deed restrictions shall specify that no trees, fences, structures or hardscape are allowed within the easement boundaries, and that maintenance access must be provided. The Town will prepare the deed language and the Applicant's surveyor shall prepare the legal description and plat. The Applicant shall pay any recordation costs. 73. QUIT~LAIM OF EASEMENT: The abandonment ofthe existing S.D .E., P.S.S.E & E.V .A.E. shall be recorded, and a copy of the recorded quitclaim ~hall be submitted to the Engineering Division of the Parks and Publ ic Works Department, prior to issuance of building permit. 74. ROLLED CURB REPAIR : The Applicant shall repair and replace to existing Town standards any rolled curb and gutter damaged now or during construction of this project. All new and existing adjacent infrastructure must meet Town standards. New rolled curb shall be constructed per Town Standard Details. New concrete shall be free of stamps, logos, names, graffiti, etc. Any concrete identified that is displaying a stamp or equal shall be removed and replaced at the Contractor's sole expense and no additional compensation shall be allowed therefore. The limits of rolled curb repair will be determined by the Engineering Construction Inspector during the construction phase of the project. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. 75. SIGHT TRIANGLE AND TRAFFIC VIEW AREA: Any proposed Improvements, including but not limiting to trees and hedges, will need to abide by Town Code Sections 23.10.080, 26 .10.065, and 29.40.030. 76. TRAFFIC IMPACT MITIGATION FEE: Prior to the issuance of a building or grading permit, the Applicant shall pay the project's proportional share of transportation improvements needed to serve cumulative development within the Town of Los Gatos. The fee amount will be based upon the Town Council resolution in effect at the time the building permit is issued. The amount based on the current resolution is $8,587.04. The fee shall be paid before issuance of a building permit. The final traffic impact mitigation fee for this project shall be calculated from the final plans using the current fee schedule and rate schedule in effect at the time the building permit is issued, using a comparison between the existing and proposed uses. 77. CONSTRUCTION STREET PARKING: No vehicle having a manufacture's rated gross vehicle weight exceeding ten thousand (10,000) pounds shall be allowed to park on the portion of a street which abuts property in a residential zone without prior to approval from the Town Engineer. 78. HAULING OF SOIL: Hauling of soil on-or off-site shall not occur during the morning or evening peak periods (between 7 :00 a.m. and 9:00 a.m . and between 4:00 p .m. and 6:00 p.m.), and at other times as specified by the Director of Parks and Public Works. Prior to the issuance of a building permit, the Applicant shall work with the Town Building Department and Engineering Division Inspectors to devise a traffic control plan to ensure safe and efficient traffic flow under periods when soil is hauled on or off of the project site. This may include, but is not limited to provisions for the Applicant/Owner to place construction notification signs noting the dates and time of construction and hauling activities, or providing additional traffic control. Coordination with other significant projects in the area may also be required. Cover all trucks hauling soil, sand and other loose debris. 79. CONSTRUCTION HOURS: All site improvements and construction activities, including the delivery of construction materials, labors, heavy equipment, supplies, etc., shall be limited to the hours of 8:00 a.m . to 8:00 p.m., weekdays and 9:00 a.m. to 7:00 p.m. weekends and holidays. The Town may authorize, on a case-by-case basis, alternate construction hours. The Applicant shall provide written notice twenty-four (24) hours in advance of modified construction hours. Approval of this request is at discretion of the Town. 80. CONSTRUCTION NOISE: Between the hours of 8:00 a.m. to 8:00 p.m., weekdays and 9:00 a.m. to 7 :00 p.m. weekends and holidays, construction, alteration or repair activities shall be allowed. No individual piece of equipment shall produce a noise level exceeding eighty- five (85) dBA at twenty-five (25) feet from the source. If the device is located within a structure on the property, the measurement shall be made at distances as close to twenty-five (25) feet from the device as possible. The noise level at any point outside of the property plane shall not exceed eighty-five (85) dBA. 81. CONSTRUCTION MANAGEMENT PLAN SHEET: Prior to the issuance of any permits, the Applicant shall submit a construction management plan sheet (full-size) within the plan set that shall incorporate at a minimum the Earth Movement Plan, Project Schedule, employee parking, construction staging area, materials storage area(s), concrete washout(s) and proposed outhouse location(s). Please refer to the Town's Construction Management Plan Guidelines document for additional information. 82. MAINTENANCE ACCESS: Prior to the issuance of any permits, the Applicant shall propose maintenance access Improvements for the Town Engineer to review, comment on, and approve. The Engineering Di v ision of the Parks and Public Works Department shall approve the surface materials over each public easement. 83. EMERGENCY VEHICLE ACCESS: The Emergency Vehicle Access Easement that traverses the Project Site shall be kept open and In a safe, drive-able condition throughout construction. If temporary closure is needed, then formal written notice shall be provided at least one week In advance of closure. 84. EMERGENCY VEHICLE ACCESS EASEMENT: Prior to the issuance of any permits, the Applicant shall ·coordinate with the Santa Clara County Fire Department to ensure that any proposed modifications to the Emergency Vehicle Access Easement that traverses the Project Site are curvilinear, allows for the Department's equipment to travel across said easement, and meets all Department specifications. Plans shall be submitted to the Santa Clara County Fire Department for approval prior to construction. 85. WVSD (West Valley Sanitation District): A Sanitary Sewer Clean-out is requ ired for each property at the property line, or at a location specified by the Town. 86 . SANITARY SEWER BACKWATER VALVE : Drainage piping serving fixtures which have flood level rims less than twelve (12) inches (304.8 mm) above the elevation of the next upstream manhole and/or flushing inlet cover at the public or private sewer system serving such drainage piping shall be protected from backflow of sewage by installing an approved type backwater valve. Fixtures above such elevation shall not discharge through the backwater valve, unless first approved by the Building Official. The Town shall not incur any liability or responsibility for damage resulting from a sewer overflow where the property owner or other person has failed to install a backwater valve as defined in the Uniform Plumbing Code adopted by the Tow11 and maintain such device in a functional operation condition. Evidence of West Sanitation District's decision on whether a backwater device is needed shall be provided prior to the issuance of a building permit. 87. BEST MANAGEMENT PRACTICES (BMPs): The Applicant is responsible for ensuring that all contractors are aware of all storm water quality measures and that such measures are implemented. Best Management Practices (BMPs) shall be maintained and be placed for all areas that have been graded or disturbed and for all material, equipment and/or operations that need protection: Removal of BMPs (temporary removal during construction activities) shall be replaced at the end of each working day. Failure to comply with the construction BMP will result in the issuance of correction notices, citations, or stop work orders. 88. STORMWATER DEVELOPMENT RUNOFF: All new development projects ar~ subject to the stormwater development runoff requirements. Every Applicant shall submit a stormwater control plan and implement conditions of approval that reduce stormwater pollutant discharges through the construction, operation and maintenance of treatment measures and other appropriate source control and.site des ign measures. Increases in runoff volume and flows shall be managed in accordance with the development runoff requirements. 89. SITE DESIGN MEASURES: All projects shall incorporate the following measures: a. Protect sensitive areas and minimize changes to the natural topography. b. Minimize impervious surface areas . c. Direct roof downspouts to vegetated areas. d. Use porous or pervious pavement surfaces on the driveway, at a minimum. e. Use landscaping to treat stormwater. 90. LANDSCAPING: In finalizing the landscape plan for the retention pond area(s), it is recommended that the landscape architect ensure that the characteristics of the selected plants are similar to those of the plants listed for use in bioretention areas i n Appendix D of the Santa Clara Valley Urban Runoff Pollution Prevention Program (SCVURPPP) C.3 Stormwater Handbook. 91. EROSION CONTROL: Interim and final erosion control plans shall be prepared and submitted to the Engineering Division of the Parks and Public Works Department. A maximum of two (2) weeks is allowed between clearing of an area and stabilizing/buil ding on an area if grading is allowed during the ra i ny season. Interim erosion control measures, to be carried out during construction and before Installation of the final landscaping, shall be included. Interim erosion control method shall i nclude, but are not limited to: silt fences, fiber rolls (with locations and details), erosion control blankets, Town standard seeding specification, filter berms, check dams, retention basins, etc. Provide erosion control measures as needed to protect downstream water quality during winter months. The Town of Los Gatos Engineering Division of the Parks and Public Works Department and the Building Department will conduct periodic NP DES inspections of the site throughout the recognized storm season to verify compliance with the Construction General Permit and Stormwater ordinances and regulations. 92. DUST CONTROL: Blowing dust shall be reduced by timing construction activities so that paving and building construction begin as soon as possi ble after completion of grading, and by landscaping disturbed soils as soon as possible . Further, water trucks shall be present and in use at the construction site. All portions of the site subject to blowi ng dust shall be watered as often as deemed necessary by the Town, or a minimum of three (3) times daily, or apply (non- toxic) soil stabilizers on all unpaved access roads, parking areas, and staging areas at construction sites in order to insure proper control of blowing dust for the duration of the project. Watering on public streets shall not occur. Streets shall be cleaned by street sweepers or by hand as often as deemed necessary by the Town Engineer, or at least once a day. Watering associated with on-site construction activity shall take place between the hours of 8 a.m. and 5 p.m. and shall include at least one (1) late-afternoon watering to minimize the effects of blowing dust. All public streets soiled or littered due to this construction activity shall be cleaned and swept on a daily basis during the workweek to the satisfaction of the Town. Demolition or earthwork activities shall be halted when wind speeds (instantaneous gusts) exceed twenty-five (25) miles per hour (MPH). All trucks hauling soil, sand, or other loose debris shall be covered. 93. DETAILING OF STORMWATER MANAGEMENT FACILITIES : Prior to the issuance <?f any per mits, all pertinent details of a~y and all proposed stormwater management facilities, includi ng, but not limited to, ditches, swales, pipes, bubble-ups, dry wells, outfalls, infiltration trenches, detenti on basins and energy diss i paters, shall be provided on submitted plans, reviewed by the Engineering Division of the Parks and Public Works Department, and approved for implementation. 94. CONSTRUCTION ACTIVITIES : All construction shall conform to the latest requirements of the CASQA Stormwater Best Management Practices Handbooks for Construction Activities and New Development and Redevelopment, the Town's grading and erosion control ordinance, and other generally accepted engineering practices for erosion control as required by the Town Engineer when undertaking construction activities. 95. WATER FEATURES: New swimming pools shall have a connection to the sanitary sewer system, subject to West Valley San itation Di strict's authority and standards, to facilitate draining events. Discharges from this feature shall be directed to t he sanitary sewe r and are not allowed into the storm drain ~ystem . 96. SITE DRAINAGE: Rainwater leaders shall be discharged to splash blocks. No through curb drains will be allowed. Any storm drain inlets (public or private) directly connected to public storm system shall be stenciled/signed with appropriate "NO DUMPING -Flows to Bay" NPDES required language. On-site drainage systems for all projects shall i nclude one.of the cilternatives lnciuded in section C.3.i of the Municipal Regional NPDES Permit. These include storm water reuse via cisterns or rain barrels, directi ng runoff from impervious surfaces to vegetated areas and use of permeable surfaces. No improvements shall obstruct or divert runoff to the detriment of an adjacent, downstream or down slope property. 97. OFF-SITE DRAINAGE : The Applicant shall construct and install a private on-site storm drain system that is adequately sized to collect and convey adjacent off-site tributary drai nage. Hydraulic calculations for a 100-year storm event shall provide documentation that the proposed storm drain system can convey said off-site drainage as well as on-site drainage during this event over, within, through and off the site, and ultimately into the Town's storm drain system . 98. STORM WATER MANAGEMENT PLAN: A storm water management shall be included with the gradi ng permit application for all Group 1 and Group 2 projects as defined in the amended provisions C.3 of the Municipal Regional Stormwater NPDES Permit, Order R2-2015-0049, NPDES Permit No. CAS612008. The plan shall delineate source control measures and BMPs together with the sizing calculations. The plan shall be certified by a professional pre~qualified by the Town. In the event that the storm water measures proposed on the Plann i ng approval differ significantly from those certified on the Build i ng/Grading Permit, the Town may require a modification of the Planning approval prior to release of the Building Permit. The Applicant may elect to have the Planning submittal certified to avoid thi s possibility. 99. STORM WATER MANAGEMENT PLAN NOTES: The following note shall be added to the storm water management plan: ''The biotreatment soil mix used in all stormwater treatment landscapes shall comply with the specifications in Attachment L of the MRP. Proof of compliance shall be submitted by the Contractor to the Town of Los Gatos a minimum of thirty (30) days prior to delivery of the material to the job site using the Blotreatment Soil Mix Supplier Certification Statement." 100. STORM WATER MANAGEMENT PLAN CERTIFICATION : Certification from the biotreatment soils provider is required and shall be given to Engineering Divi sion Inspection staff a minimum of thirty (30) days prior to delivery of the material to the job site. Additionally deliver tags from the soil mix shall also be provided to Enginee r ing Division Inspection staff. Sample Certification can be found here: http://www.scvurppp- w2k.com/nd_wp.shtml?zoom_h ighlight=BIOTREATMENT +SOIL. 101. AGREEMENT FOR STORMWATER BEST MANAGEMENT PRACTICES INSPECTION AND MAINTENANCE OBLIGATIONS: The property owner shall enter i nto an agreement with the Town for maintenance of the stormwater filtration devices required to be installed on this project by the Town's Stormwater Discharge Permit and all current amendments or modifications. The agreement shall specify that certain routine maintenance shall be performed by the property owner and shall specify device maintenance reporting requirements . The agreement shall also specify routine inspection requ i rements, permits and payment of fees. The agreement shall be recorded, and a copy of the recorded agreement shall be submitted to the Engineering Division of the Parks and Public Works Department, prior to the release of any occupancy permits. 102. SILT AND MUD IN PUBLIC RIGHT-OF-WAY: It is the responsibility of Contractor and homeowner to make sure that all dirt tracked into the public right-of-way is cleaned up on a daily basis. Mud, silt, concrete and other construction debris SHALL NOT be washed into the Town's storm drains. 103. GOOD HOUSEKEEPING: Good housekeeping practices shall be observed at all times during the course of construction. All construction shall be diligently supervised by a person or persons authorized to do so at all times during working hours. The Applicant's representative in charge shall be at the job site during all working hours. Failure to maintain the public right-of-way according to this condition may result in penalties and/or the Town performing the required maintenance at the Applicant's expense. 104. PERMIT ISSUANCE : Permits for each phase; reclamation, landscape, and grading, shall be issued simultaneously. 105. COVERED TRUCKS: All trucks transporting materials to and from the site shall be covered. TO THE SATISFACTION OF THE SANTA CLARA COUNTY FIRE DEPARTMENT: 106. EMERGENCY VEHCILE ACCESS EASEMENT (EVAE): The realignment of the emergency vehicle access easement on the project site as noted in the 'Project Description' on page A-0.0 of the plans is being done at the request of the applicant/owner. The Santa Clara County Fire Department has not and is not requesting or requiring this action. However, the Department has no objection to this action, provided that the access to the easement is not compromised and the following: a. The EVAE shall not be used for parking. b. The Engineer of record must certify, in writing, that this EVAE and all installations of alternate road surfacing, such as 'grasscrete meets applicable requirements of CFC Sec. 503 and SCCFD SD&S A-1. c. The EVAE is to remain free and clear of obstructions at all times. 107. WILDLAND-URBAN INTERFACE: The project is located within the designated Wildland- Urban Interface Fire Area. The building construction shall comply with the provisions of California Building Code (CBC) Chapter 7A. Note that vegetation clearance shall be in compliance with CBC Section 701A.3 .2.1 prior to project final approval. Check with the Planning Department for related landscape plan requirements. 108. FIRE SPRINKLERS REQUIRED : An automatic residential fire-sprinkler system shall be installed in one-and two-family dwellings as follows. In all new one-and two-family dwellings and in existing one-and two-family dwellings when additions are made that increase the building area to more than 3,600 square feet. Exception : A one-time addition to an existing building that does not total more than 1,000 square feet of building area. Note: The owner(s), occupant{s) and any contractor(s) or subcontractor(s) are responsible for consulting with the water purveyor of record in order to determine if any modification or upgrade of the existing water service is required. Note: Covered porches, patios, balconies, and attic spaces may require fire sprinkler coverage. For buildings in excess of 6200 square feet the (4) four most hydraulically demanding heads in a room or compartment shall calculated. 109. WATER SUPPLY REQUIREMENTS: Potable water supplies shall be protected from contamination caused by fire protection water supplies. It is the responsibility of the applicant and any contractors and subcontractors to contact the water purveyor supplying the site of such project, and to comply with the requirements of that purveyor. Such requirements shall be incorporated Into the design of any water-based fire protection systems, and/or fire suppression water supply systems or storage containers that may be physically connected in any manner to an appliance capable of causing contamination of the potable water supply ofthe purveyor of record. Final approval of the system{s) under consideration will not be granted by this office until compliance with the requirements of the water purveyor of record are documented by that purveyor as having been met by the applicant(s). 2010 CFC Sec. 903.3.5 and Health and Safety Code 13114.7. 110. FIRE DEPARTMENT CONNECTION: For buildings In excess of 6,200 square feet, a fire department connection (FDC) shall be provided. The FDC shall consist of at least one 2.5" hose connection that is connected to the sprinkler rise with a pipe no less than the diameter of the sprinkler riser. A State of California licensed (C-16) Fire Protection Contractor shall submit plans, calculations, a completed permit application and appropriate fees to this department for review and approval prior to beginning their work. CRC Sec. 313.2 as adopted and amended by LGTC. 111. CONSTRUCTION SITE FIRE SAFETY: All construction sites must comply with applicable provisions ofthe CFC Chapter 33 and our Standard Detail and Specification 51-7 . Provide appropriate notations on subsequent plan submlttals, as appropriate to th~ project. CFC Chp 33. 112. ADDRESS INDENTIFICATION: New and existing buildings shall have approved address numbers, building numbers, or approved building identification placed In a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Where required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall be a minimum of 4 inches (101.6 mm) high with a minimum stroke width of 0.5 inch (12 .7 mm). Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address numbers shall be maintained. CFC Sec. 505.1. N:\DEV\CONDmONS\2017\Foster20102 08-23-17 PC.docx This Page Intentionally Left Blank · ( ORDINANCE 2088 ORDINANCE OF THE TOWN OF LOS GATOS AMENDING THE ZONING ORDINANCE EFFECTING A ZONE CHANGE FROM RC AND HR-S TO HR-2 Yi:PD AND RC:PD AT 17975 FOSTER ROAD THE TOWN COUNCIL OF THE TOWN OF LOS GATOS DOES ORDAIN AS FOLLOWS: SECTION I The Town Code of the Town of Los Gatos is hereby amended to change the zoning at 17975 Foster Road as shown on the map which is attached hereto marked Exhibit A and is part of this Ordinance from RC (Resource Conservation), andHR-5 (Hillside Residential, 5 to 40 acres per dwelling unit) to HR-2 1/2:PD (Hillside Residential, 2 ~ to 10 acres per dwelling unit, Planned Development) and RC:PD (Resource Conservation, Planned Development). SECTION II The PD (Planned Development Overlay) zone established by this Ordinance authorizes the following construction and use of improvements (the demolition of the single family residence and buildings associated with Guadalupe College are handled separately under the Architecture and Site applications since the buildings are considered a public nuisance and a hazard). 1. Creation of six home sites; 2 . Vineyard; 3. Landscaping, streets, trails, open space and other site improvementS shown and required on the Official ·Development Plan; · 4. Creation of a mutual water company; 5. Uses permitted are those specified in the HR (Hillside Residential) and RC (Resource Conservation) zones by Sections 29.40.160 and 29.40.235 (Permitted Uses) and 29.20 .185 (Conditional Uses) of the Town Code, as those sections exist at the time of the adoption of this Ordinance, or as they may be amended in the future. However, no use listed in Section 29 .20 .185 is allowed unless specifically authorized by this Ordinance, or by Conditional Use Permit. Page 1 of 12 EXHIBIT 4 SECTION III COMPLIANCE WITH OTHER DEVELOPMENT STANDARDS All provisions of the Town Code apply, except when the Official Development Plan specifically shows otherwise. SECTION IV Architecture and Site Approval is required before the demolition of the single family residence and other buildings associated with Guadalupe College, or any construction work for the dwelling units, vineyard and water tank is performed, whether or not a permit is required for the work and before any permit for construction is issued. Construction permits shall only be in a manner complying with Section 29.80.130 of the Zoning Ordinance. SECTIONV The attached Exhibit A (Map) and Exhibit B (Development Plans, 18 sheets), are part of the Official Development Plan. The following must be complied with before issuance of any grading, demolition or construction permits: TO THE SATISFACTION OF THE DIRECTOR OF COMMUNITY DEVELOPMENT: (Planning Division) l. HILLSIDE SPECIFIC PLAN. The approval of this Official Development Plan is contingent upon the County of Santa Clara adopting the proposed amendments to the Hillside Specific Plan. 2. ARCHITECTURE AND SITE APPROVAL REQUIRED. The Official Development Plan is conceptual only in terms of home placement, building, tank and vineyard footprints, and house plans~ Separate Architecture and Site Applications and approvals shall be required for each of the residential units (and fencing), the vineyard and the storage tanks. Any changes or modifications made to the approved Architecture and Site plans shall be approved by the Director of Community Development or the Planning Commission, depending on the scope of the change(s). 3. URBAN SERVICE AREA. The developer shall receive approval from LAFCO to expand the urban service area boundary to encompass Lot 5, prior to the issuance of a building permit for the house. Page 2 of 12 4. FUTIJRE SUBDMSIONS. There shall be no future subdivision of the subject site. 5. DESIGN GUIDELINES. All Architecture and Site applications are subject to the Town's Hillside Design Guidelines or the guidelines submitted by the applicant, whichever is more restrictive. 6. VINEYARD . If the vineyard is for a business operatio~ the applicant shall obtain an operator ID and/or a Restricted Material Permit as required by the Office of the County Agricultural Commission prior to the issuance of a business license. 7. TREE REMOVAL PERMIT. A Tree Removal Permit shall be obtained prior to the issuance of a Building, Grading or Encroachment Permit 8. SOLAR. During the Architecture and Site application process, all new residences, to the extent feasible, shall be designed to take full advantage of passive solar opportunities. Each residence shall be pre-plumbed for solar hot water heating and shall comply with the Town's Conservation Element of the General Plan. 9. BMP FEES .. An in-lieu fee of building a Below Market Price unit shall be paid. The fee shall be equal to six percent of the Building Permit valuation of each house which shall be detennined by the Community Development Director. Fees shall be paid prior to occupancy of each unit. 10. CARETAKER.. A caretaker unit is permitted on the site during construction of the subdiYision improvements and. until final occupancy has been received for all of the houses. ·. . 11. *RED RIBBONS . Prior to issuance of a building permit, a survey for Santa Clara red ribbons shall be conducted at the developer's expense to determine its presence or absence on home sites located in undeveloped areas (Lots 4 through 6) including all areas where disturbance could occur as part of home construction. 1b.is survey shall also include any areas along the final haul road alignment that deviate from the July, 1999 alignment that was already surveyed. A.Dy areas found to be supporting this species should be avoided and if avoidance is infeasible, a mitigation and monitoring pla:c1 detailing the location and acreage of off-site mitigation should be de veloped based on consultation with the appropriate agency . 12. *NES11NG SEASON. If any construction activities occur during the ·nesting season (Februa,cy . to August), these actiVities shall be preceded by pre-coilstruction surveys for nesting raptors by· a qualified ornithologist at the developer's expense. Surveys shall be conducted no more than 30 days prior to the start of construction. No construction activities (including tree removal , grading, etc) that would result in disturbance to active raptor nests shall be allowed to proceed. A qualified ornithologist shall determine the extent of construction-free zones around active raptor nests located during surveys. The USFWS and CDFG shall also be notified of any active raptor nest within the construction zone. 13. *LIME KILNS. The historic lime kilns shall be researched and documented on a Department P age 3 of 12 ( of Parks and Recreation (DPR) fo rm at the developer's expense prior to issuance of a grading and/or building permit. The area containing the lime kilns shall be surrounded by orange construction fencing prior to initiation of construct ion activities for the proposed project in order to prevent any unintentional encroachment into this cultural resource. A qualified archaeologist shall conduct spot check monitoring of construction activities when these activities occur in native soils on the property. 14. *MUTUAL BENEFIT WATER COMP ANY. The proposed mutual benefit water company shall be restricted to providing domestic water service to only the six proposed lots on the project site. The company shall specify that the remaining storage capacity shall be reserved in perpetuity solely for fire fight ing purposes on the site and the Foster Road neighborhood. This company shall not provide domestic water service to any off-site res idential lots . 15. THRESHOLDS FOR MUTUAL BENEFIT WATER COMPANY. Minimum thresholds for domestic water supply shall be met to the satisfaction of the Director of Community Development and the Director of Parks and Public Works or San Jose Water Company, whichever is more restrictive. These thresholds shall be established prior to recordation of the final map. The Mello-Roos District does not apply to this application. 16. TIMING OF MUTIJAL BENEFIT WATER CO.MP ANY . The mutual benefit water company shall be established to the satisfaction of the Town Attorney, the County of Santa Clara and the State of California prior to the recordation of the final map . 17. SLOPE DENSITY MAP . The slope density map, sheet C2 of the Official Development Plan , is for reference only . TO THE SATISFACTION OF THE DIRECTOR OF PARKS AND PUBLIC WORKS: (Engineering Section) 18 . RECORDATION. Documents shall be recorded at the applicanf s expense or each individual lot referencing that an in-lieu fee of building a Below Market Price unit and a traffic impact mitigation fee are required prior to final occupancy. These documents shall be recorded simultaneously with the final map . The documents shall be prepared by the Director of Community Development. 19. *GRADING WHEN WINDY. Grading activities shall be suspended when winds (instantaneous gusts) exceed 25 mph. 20. *ENTRYWAY. The entryway to the proposed subdivision shall contain a plaque referenc ing the house and some stone work from the existing house. This plaque shall be installed prior to finalizin g subdivis ion improvements. The design of the plaque and the information provided on the plaque shall be approved by the Director of Community Development. 21. *PRECONSTRUCTION SURV EY. The developer shall complete a preconstruction survey of Foster Road to document road conditions prior to issuance of a grading and/or building permit . Page4 of 12 A video shall be included with the survey. 22. BOND. A bond shall be provided by the developer for the repair of Foster Road to the satisfaction of the Director of Parks and Public Works and the Town Attorney. 23. *POST·CONSTRUCTION SURVEY . The Town shall conduct a post.construction survey of Foster Road to determine whether any road damage occurred as a result of project construction. 24. *ROAD REP AIRS. The developer shall be responsible for completing any required road repairs. 25. *TRAFFIC CONTROL PLAN. The developer shall provide a traffic control plan (e.g. requiring flagpersons along one lane sections of Foster Road for equipment/material deliveries, specifying hours, and notifying neighbors in advance) to minimize the potential for traffic safety problems and delays to local residents prior to issuance of any permits. This plan shall be approved by the Town prior to commencement of any construction activities on Foster Road. 26. GRADING PERMIT. A grading permit is required for site grading, including building p~ and erosion control. A separate application for a grading permit (with grading plans) shall be made to the Engineering Division of the Parks & Public Works Department. The grading plans shall include final grading, drainage retaining wall location, driveway, utilities and interim erosion control. Unless specifically allowed by the Director of Parks and Public Works, the grading permit will be issued concurrently with the building permit. 27. G~rNG. · All grading shall be kept to a IDinimUill to constru~t the public roads. Final grading for all lots shall be determined at the Architecture and Site approval process. The grading on lots 1, 2, 3 and 6 shall retain a more natural contour to reduce the grading. The grading plan, the soil and geotechnical report and the remedial grading provided in Exhibit X, Sections 4, 8 and 9 (from the Report to the Planning Commission from the Development Review Committee dated May 3, 2001 for the meeting of May 9, 2001) shall be provided by the applicant and incorporated in the final plans. 28. STOCK.PILING. Stockpiling of material is permitted to the satisfaction of the Director of Parks and Public Works and the Director of Community Develo:pment. 29. SOILS REPORT. One copy of the soils and geologic report shall be submitted with the grading permit and one witli the public improvei,tient application. The soils. report shall include specific criteria and standards governing site grading, drainage; pavement design; ret8ining wall design and erosion control. The reports shall be signed and "wet stamped" by the engineer or geologist, in conformance with Section 6735 of the California Business and Professions Code. 30. FINAL MAP. A final map shall be recorded. Two copies of the final map shall be submitted to the Engineering Division of the Parks & Public Works Department for review and approval. Submittal shall include closure calculations, title reports and appropriate fee. The map shall be recorded before any permits are issued. Page 5 of 12 ( 31. FINAL CC&R'S . Final CC&R's shall be approved by the Town Attorney prior to recordation of the final map . The CC&R's shall include provisions for the maintenance of the shared driveway . 32 . DEDICATIONS. The following shall be dedicated on the final map. The dedication shall be recorded before any permits are issued. a. Foster Road. A 40-foot street right-of-way with a standard 42-foot radius cul-de-sac. b. Public Service Easement (PSE). Ten (10) feet wide, next to the Foster Road right-of-way. c. Ingress-egress, storm drainage and sanitary sewer easements, a,s required. d. Floating Trail Easement. Twenty (20) feet wide, as shown on the tentative map. Final location will be determined following a detailed resource analysis conducted by Midpeninsula or the developer, to identify sensitive plant and animal habitats . e. Emergency Access Easement. Twenty (20) feet wide, from Foster Road to College A venue, as shown on the Planned Development maps and tentative map. f. Open Space/Conservation and Scenic Easements. These easements shall be dedicated as shown on the approved Planned Development plans jointly to the Town and Midpeninsula Open Space District. The open space/conservation easement on Lot S will have no public access. 33 . CUL-DE-SAC. The cul-de-sac elevation shall be raised to minimize the retaining wall. 34 . CURB AND GUTTER. The curb and gutter shall be rolled with a three inch height. 35 . PUBLIC IMPROVEMENTS. Tiie following improvements shall be installed by the developer. Plans for those improvements shall be prepared by a California registered civil engineer, reviewed and approved by the Town, and guaranteed by contract, Faithful Performance Security and Labor & Materials Security before the issuance of a building permit or the recordation of a map. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. a. Foster Road Extension. Curb, gutter, retaining walls, street lights, pavement 24 feet wide, signing, striping, storm drainage and sanitary sewers, as required and a cul Ade-sac bulb with radius of 32 feet. · b. Emergency Access Road. Three coats of chip seal over six inch of compacted Class 2 asphalt base rock, 12 feet wide (except in areas where restriction is minimized). Turnouts are to be included as required . c. Trail. A minimum I 0-foot wide trail, to comply with requirements of Town Trails Committee. 3 6. UTILITY INSTALLATION. The developer shall install all utility services , including telephone, electric power and all other commwtlcations lines underground, as required by Town Code §27.50.0lS(b). Cable television capability shall be provided to all new lots. 37. INSURANCE. One million dollars ($1 ,000,000) of liability insurance holding the Town Page 6 of 12 harmless shall be provided in a format acceptable to the Town Attorney before recordation of the map. 38. TRAFFIC IMPACT MITIGATION FEE (RESIDENTIAL). The developer shall pay a proportional the projecfs share of transportation improvements needed to serve cumulative developmep.t within the Town of Los Gatos. The fee amount will be based upon the Town Council resolution in effect at the time the request of Certificate of Occupancy is made '. The-fee shall be paid before issuance of the Certificate of Occupancy. The trEiffic impact mitigation fee for this project using the current fee schedule is $5,730 per house. The final fee shall be calculated from the final plans using the rate schedule in effect at the time of the request for a Certificate of Occupancy. 39 . 401 CERTIFICATION. A 401 Certification shall be obtained from the San Francisco Bay Region Water Quality Control District for work in "waters of the State of California. 11 A copy of the certification shall be provided to the Parks & Public Works Department before the fmal map is recorded. 40. GENERAL. All public improvements shall be made according to the latest adopted Town Standard Drawings and the Town Standard Specifications. All work shall conform to the applicable Town ordinances. The adjacent public right-of-way shall be kept clear of all job related dirt and debris at the end of the day. Dirt and debris shall not be washed into stonn drainage facilities. The storing of goods and materials on the sidewalk and/or the ,street will not be allowed unless a special permit is issued. The developer's representative in charge shall be at the job site dunng all working hours. Failure to maintain th~ _public right-of-w~y according to this condition may result in the Town performing the required maintenance at the developer's expense. 41. ENCROACHMENT PERMIT. All work in the public right-of-way will require a Construction Encroachment Pennit. All work over $5,000 will require construction security. 42. PUBLIC WORKS INSPECTIONS. The developer or his representative shall notify the Engineering Inspector at least twenty-four (24) hours before starting an work pertaining to on--·· site drainage facilities, grading or paving, and all work in ~e Town's right-of-way. Failure to do so will result in rejection ow work that went on without inspection. 43. GRADING MORATORIUM. No, grading or earth-disturbirig activities shall be initiated in hillside areas between Oc~ber 1 and April 1 S of each year. For grading operations commenced before October 1, all grading or earth-disturbing activities shall cease October 15 and will not be allowed to restart until April 15. Grading pennits will not be issued between September 15 and April 15. These limitations include,'but are not limited fo these items: driveways, building pads, foundation trenches and drilled piers, retaining walls, swimming pools, ,tennis courts, outbuildings and utility trenches. Install interim erosion control measures, shown on the approved interim erosion control plan, by October 1, if final landscaping is not in place. Maintain the ~terim erosion control measures throughout the October 1 to April 1 S period. Page 7 of 12 ( 44 . GRADING INSPECTIONS . The soils engineer or her/his qualified representative shall continuously inspect all grading operations . The soils engineer shall subm it a final gr ad ing report before occupancy/Certificate of Completion. 45. SURVEYING CONTROLS . Horizontal and vertical controls shall be set and certified by a licensed surveyor or regist~red civil engineer qualified to practice land surveying, for the following items: a. Retaining wall--top of wall elevations and locations b. Toe and top of cut and fill slopes c. Building pad d. Top of curb 46 . EROSION CONTROL . Interim and final erosion control plans shall be prepared and submitted to the Engineering Division of the Parks & Public Works Department. On sites over five (5) acres, a Notice of Intent (NO!) and Storm Water Pollution Prevention Plan (SWPPP) shall be submitted to the San Francisco Bay Regional Water Quality Control Board. Grading activities shall be limited to the period ofleast rainfall (April 15 to October 1 ). A maximum of two weeks is allowed between clearing of an area and stabilizing/building on an area if grading is allowed to go on during the rainy season. In addition, straw bales and plastic sheeting shall be stored on- site for emergency control, if n~eded . Install filter berms, check dams, retention basins, silt fences and straw bale dikes as needed on the project site, to protect down stream water quality during winter months. 4 7. SILT AND MUD IN PUBLIC RIGHT-OF-WAY. It is the responsibility ofcontractor and home owner to make sure that all dirt tracked into the public right-of-way is cleaned up on a daily basis. Mud, silt, concrete and other construction debris SHALL NOT be washed into the Town's storm drains. 48 . NONPOINT SOURCE POLLUTION PREVENTION. On-site drainage systems shall include a filtration device in the catch basins or a grease and oil separator shall be installed. 49. RESTORATION OF PUBLIC IMPROVEMENTS. The developer shall repair or replace all existing improvements not designated for removal that are damaged or removed because of developer's operations. Improvements such as, but not limited to : curbs, gutters, sidewalks, driveways, signs, pavements, raised pavement markers, thermoplastic pavement markings, etc. shall be repaired and replaced to a condition equal to or better than the original condition. Existing improvement to be repaired or replaced shall be at the direction of the Engineering Construction Inspector, and shall comply with all Title 24 Disabled Access provisions. Developer shall request a walk-through with the Engineering Construction Inspector before the start of construction to verify existing conditions. 50. DRIVEWAY APPROACHES. The developer shall install six (6) Town standard residential driveway approaches. The new driveway approaches shall be constructed per Town Standard Detail. Page 8 of 12 51. AS-BUILT PLANS. After completion of the construction of all work in the public right-of-way or public easements, the original plans shall have all changes (change orders and field changes) clearly marked. The "as-built" plans shall again be signed and "wet-stamped" by the civil engineer who prepared the plans, attesting to the changes. The original "as-built" plans shall be review and approved the Engineering Construction Inspector. A Mylar of the approved 11 as- built" plans shall be provided to the Town before the Faithful Performance Security is released. · 52. SANITARY SEWER LATERAL. Sanitary sewer laterals are televised by West Valley Sanitation District and approved by the Town of Los Gatos before they are used or reused. No Certificate of Occupancy shall be given until sewer later is approved by West Valley Sanitation District and the Engineering Division Parks and Public Works Department. If one does not exist, a sanitary sewer lateral clean-out shall be installed at the property line. 53. EASEMENT RELINQUISHMENT. The property owner shall relinquish the existing St. Joseph's Hill Open Space Preserve Access and Parking easement prior to the issuance of a building permit for the first house. 54. SECURITY AND CONTRACT FOR MUTUAL BENEFIT WATER COMP ANY. The developer shall post security in a sufficient form and amount as determined by the Director of Parks and Public Works and Town Attorney, to secure the construction and future operation of the mutual benefit water compan_y. The developer shall submit a written contract which governs the fee schedule and the maintenance of the mutual benefit water company. Developer shall further provide securjty in the event. of catastrophic failure of the water system to fund an emergency water supply plan to the satisfaction of the Town Attorney, Director of Parks and Public Works and Director of Community Development These requirements shall be met prior to recordation of the final map. 55. STREET LIGHTING. Street lighting shall be minimized on the hillside for safety purposes only. (Parks Division) 56. FINAL LANDSCAPE PLAN. A final landscape plan shall be submitted during the Architecture and Site approval process. This plan shall include fencing for all lots and measures to screen the proposed water· tank adjacent to the Open Space Preserve. In addition, the developer shall plant Oak trees or other trees that are naturalized to the hilltops in the 8.rea (as opposed to Redwoods arid Cedars) for landscape screening between the Open Space Preserve and Lot 5. The tree plan provided in Section 10 of Exhibit X, (from the Report to the Planning Commission from the Development Review Committee dated May 3, 2001 for the meeting of May 9, 2001) shall be provided and incorporated in the final plans. 57 . NEW 1REES. Newly planted trees shall be double-staked, using rubber tree ties and shall be planted prior to acceptance of the subdivision improvements and/or final occupancy as determined by the Parks Superintendent. Page 9 of 12 58 . PROTECTIVE FENCING. Prior to any construction or building permits being issued, the applicant shall meet with the Director of Parks, Forestry and Maintenance Services concerning the need for protective fencing around the existing trees. Such fencing is to be installed prior to, and be maintained during, construction. The fencing shall be a four foot high chain link attached to steel poles driven two feet into the ground when at the drip line of the tree. If the fence has to be within eight feet of the trunk of the tree, a fence base may be used, as in a typical chain link fence that is rented. 59. IRRIGATION. All newly planted landscaping shall be irrigated by an in-ground irrigation system. 60. * ARBORIST. All recommendations made by Arborist Walter Levison in his report received by the Town on April 1, 1999, shall be reflected in final project plans and implemented during construction. 61 . TRAIL MAINTENANCE. The provision for the trail maintenance shall be finalized prior to the approval of the subdivision map. TO THE SATISFACTION OF mE SANTA CLARA COUNTY FIRE DEPARTMENT: 62. FIRE HYDRANTS. The applicant shall provide public fire hydrant(s) at location(s) to determined jointly by the Fire Department and the San Jose Water Company. Maximum hydrant spacing shall be 500 feet, with a minimum single hydrant flow of 1000 GPM at 20 psi, residual. If area fire hydrants exist, reflect their-location on the civil drawings included with the building permit submittal. Installation shall conform to National Fire Protection Association Standard #24 and Fire Department Standard Details and Specification W-2. 63. TIMING OF WATER SUPPLY INSTALLATIONS. Required fire service and fire hydrant installations shall be installed, tested and accepted by the Fire Department prior to the start of framing. B,ulk construction materials shall not be delivered to the site until installations are completed as stated above. Building permit issuance may be withheld until installations are completed. 64 . TIMING OF ROADWAY INSTALLATIONS. Required driveways and/or access roads up through the fires lift of asphalt shall be inspected and accepted by the Fire Department prior to the start of construction. Bulle combustible materials shall not be delivered. to the site until installations are completed as stated above. Building permit issuance may be withheld until installations are completed. 65. REQUIRED FIRE FLOW. The developer shall provide the required fire flow from fire hydrants spaced at a maximum of 500 feet or provide an approved fire sprinkler system throughout all portions of the building. The fire sprinkler system shall conform to National Fire Protection Association Standard #13D, 1994 Edition, and local ordinance requirements . The fire sprinkler valving shall be installed per Fire Department Standard Detail and Specification W-I/SP-4. Page 10 of 12 66. ROAD. The road shall have a vertical clearance of 13 feet six inches, minimum turning radius of 36 feet outside and 23 feet inside, and a maximum slope of 15 percent. 67. DRIVEWAY. The driveway shall have a minimum unobstructed width of 12 feet, a vertical clearance of 13 feet six inches, minimum turning radius of36 feet outside and 23 feet inside, and a maximum slope of 15 percent. Installations shall conform with Fire Department Standard Details and Spec;ifications 68. FIRE LANE MARKINGS. The developer shall provide marking for all roadways within the project. Markings shall be per fire department specifications. Installations shall also conform to Local Government Standards and Fire Department Standard Details and Specifications A-6. 69. EMERGENCY ACCESS ROAD. The developer shall provide a secondary access (emergency vehicle access). The developer shall provide the following prior to filing for a building permit: a. A copy of the written description of the emergency vehicle access easement. c. Written documentation that the emergency access roadway bas been recorded with the Santa Clara County Recorder's Office. · c. ~ritten documentation that a maintenance agreement for the emergency access road has been recorded with the Santa Clara County Recorder's Office. 70. GA TE. When open, gates shall not obstruct any portion of the required access road or driveway width. If provided, all locks s~l be~ department approved . Installations shall conform with Fire Department Standard Details and Specifications G-1. · 71. DEMOLITION. The developer shall submit demolition proposals to the fire department for hazardous material compliance review. 72. WATER SYSTEM. Prior to filing for a building permit, the developer shall identify whether the new water system and fire hydrants shall be considered as a public or private water system. The identity of the operator(s) and the proposed responsibility for maintenance of the system shall also be provided. A3 a condition of the mutual benefit water company, mi.nlliium thresholds for fire safety shall provided to the satisfaction of the Fire Department. 73. REQUIRED PLANS AND PERMITS .. The developer .shall submit plans for fire apparatus access roads and fire hydrant systems to the Fire Department for review and approval prior to coristruction: Permits are reqUired for the installation of all private water supply, tank and hydrant systems and must be issued to contractors prior to the start of installation of such systems. 74. ADDITIONAL FIRE PROTECTION. The developer shall provide a cross connection from the fire suppression water supply to the domestic water supply in the reservoir. *Required as mitigation measures for the Mitigated Negative Declaration. Page 11 of 12 SECTION VI This Ordinance was introduced at a regular meeting of the Town Council of the Town of Los Gatos on June 18, 2001, and adopted by the following vote as an ordinance of the Town of Los Gatos at a meeting of the Town Council on July 2 , 2001 and takes effect 30 days after it is adopted. COUNCIL MEMBERS : AYES: Randy Attaway, Sandy Decker, Steve Glickman, Mayor Joe Pirzynski. NAYS : None ABSENT: Steven Blanton. ABSTAIN: None SIGNED : ATTEST: Is l Marian V. Cosgrove CLERK OF THE TOWN OF LOS GATOS LOS GATOS, CALIFORNIA Isl Joe Pirzynski MAYOR OF THE TOWN OF LOS GATOS LOS GATOS, CALIFORNIA Page 12 of 12 Project Description May 25, 2017 20102 Foster Road -APN 527-33-00 Architecture and Site Application S-14-122 ~,.\Lot-I Z...2- Vifo.'( ::;. (i 2011 TO\'/'.'-! CF LO~ <?ATOS PU,!~:.:!.\...:: [,-;\. ,...,iON Requesting approval to construct a new 5,433 square foot single famlly residence with 736 square foot 3-car garage with an exclusively below grade 3,315 square foot cellar plus a 228 square foot accessory building for a property zoned HR-2 1h PD. This application also requests approval to redesign an existing EVAE (Emergency Vehicular Access Easement) The proposed residence echoes the architecture of an Italian County home with low pitched rooflines using varying roof llnes and a mix of Earth tone stucco plaster and rustic, stone walls. Several porch elements were added on facades that face the viewing platform to aid in concealing the walls in dark shadow, resulting in an LRV well below the allowable tone. The overall height of the residence is less than 18 feet in height. Much of the fa~de was designed to be set back from the edge of the LRDA and is not visible from the viewing platform order to minimize visual Impacts from the valley's floor allowing the natural hillside contours and vegetation to stand out virtually uninterrupted. The proposed swimming pool Is positioned within a small courtyard defined by the main house and accessory structure to provide for the residents privacy. Ornamental landscaped areas are minimized and located within 30 feet of the proposed main dwelling. The majority of the site will remain in a natural state. Additional off-street parking is provided on site within the existing driveway areas . The design for the proposed development meets each and every zoning requirement and objective described in the HDS&G. A request for a minor exception to locate a minimal portion of the 20 ~ wide EVAE outside the border of the LRDA will be used to bring the site in compliance with the HDS&G. EXHIBIT 5 This Page Intentionally Left Blank Justification Letter July 14, 2017 20102 Foster Road -APN 527 -33-00 Architecture and Site Application S-14-122 RECEIVED JUL ? 5 2017 ~\'f-\'ZZ. TOWN OF LOS GATOS PLANNING DIVISION As required by the Town of Los Gatos Application requirements for Development Review, when a project is requesting any exception from the Planning and Zoning Codes, a Justification Letter is required to explain why the project is not able to be in compliance. The deviations from the Hillside Standards & Guidelines that were identified as not being in compliance are listed below: • Justification for relocating the EVAE. • Justification for development outside of the LRDA Justification for relocating the Emergency Vehicle Access Easement - The purpose of the Emergency Vehicle Aocess Easement (E.V.A.E.) is to provide access through the site to property managed by the Mid-Peninsula Reginal Open Space Distridlocated along the southern portion of the site. The size and configuration of the existing Emergency Vehicle Aa:.ess Easement is established much larger than the required 20 foot width . Its irregular shape currently modulates well outside of t he limits of the LRDA onto site areas with a greater than a 30% slope and arbitrarily reduces the buildable area within the LRDA. The owners seek to re- prescribe an E.V.A.E. that strikes a balance by better meets the Town 's Hillside Development Guidelines & Standards and providing the owners with a more usable area on their land. This building pad was graded flat in 1964 to create a parking lot for the Guadalupe College. This same graded pad endures today in its Un-natural appearing state; representing how nQt to grade a site using the Town's HDS&G. By minimizing the width to 20 feet and gradually dep ressing the Emergency Vehicle Access Roadway within the grading limits, a transformation takes place that brings the site's erroneously graded pad into compliance with several of the Standards and Guidelines. This proposed location of the Emergency Vehicle Access Easement minimizes site impacts and -better emulates the natural terrain by removing the hard and abrupt edge that defines the man made building pad and the fill slope downhill. Additionally, the new E.V.A.E. location incorporates erosion control measures, is smaller in scale, promotes safer recreational l!se and removes the visual impact that exi sts today. Specifically, under Site Preparation he following Standards would become more into compliance: • Grading shall be kept to a minimum and shall be performed in a way that respects all significant natural features and visually blends with adjacent natural features. EXHIBIT 6 • Graded areas shall appear as smooth flowing contours of varying gradients, preferably with slopes of 2: 1 to 5: 1 Sharp cuts and fills and long linear slopes that have uniform grade shall be avoided. • Pad and Terrace Grading should be avoided to the maximum extent possible. If these techniques are used, the pad oonfiguration should be softened with variable, undulating slopes created to give a more natural appearance. Whereas these Standards and Guidelines were not in use in 1964, they can be used today to bring this site more into compliance with the HDS&G and provide a more natural appearance to the site by eliminating the harsh, abrupt and un-natural contours that exist today. By vertically modulating the EVAE and incorporating different materials and shapes into its design, the EVAE no longer will be broadcast as a harsh element in conflict with its environment Instead it will blend with the site and provide the owners with a fire brake, erosion control, and reclaims usable yard area for recreation and enjoyment by reducing the width of the Emergency Vehicle Aa:.ess Easement to 20 feet. Justification development outside of the LRDA- The only element that is proposed outside of the LRDA is a small portion of the 12 foot wide Emergency Vehicle Access Road. A portion of the existing E.V.A.E. is also located outside of the site's LRDA. Whereas the E.V.A.E. can be considered as "development area " , the HDS&G addresses development area and LRDA within Planned Development Projects in Chapter VIII, Section C. and Section E (4). The proposed re-alignment of the EVAE and location of the emergency vehide access is "aligned to conform as dose as possible to the existing grades and minimizes the need for grading on slopes. "1e road does not greatly alter the physical and visual character of the hillside by creating large notches in ridgelines or by defining a wide straight alignment n Additionally, the road will have gently graded banks that will be irrigated to ensure maintenance of landscape until It is pennanently landscaped. The new location of the Emergency Vehicle Aa;ess Road will meet the maximum cut and fill depth requirements and graded areas will appear as smooth flowing contours of verifying gradients; visually blend with the natural contours. On page 15 of the HDS&G it states: 1. Locate buildings within the Least f?estridive Development Area. The buildings have been completely sited and designed to comply with the Hillside Standards & Guidelines. The residence does not exceed 18 feet in height and there is no request for a major height exception required; the majority of the residence is setback considerably from the edge of the man-made pad and as viewed from any viewing platforms will not interfere with skyline due to the hillside behind the residence; the Accessory Structure has been located to meet all required setbacks; the minimal grading retains and enhances the existing landforms and all the structures are located within the LRDA. There are no exceptions required for any grading on the site and the maximum cut and fill will not exceed the allowable depths. ... · .• -'.<." ····"'''"-·· ... · .. ' .. ' .. ·• ~I ; . ,;..' . 4 ·' " '"'' . 'i:" .. ~01~~,.F9STER ROAD· -p~OJECT DATA EXISTING CONDITIONS PROPOSED PROJECT APN 537-33-009 same Zoning district HR-2 1/2 : PD same Land use vacant single family residence General Plan Designation low density residential same Project History: July 2, 2001-TC Adopted A&S for single family Planned Development Ordinance No. 2088 PD home Subdivision Nov.5, 2002 PC approved Six lot Hillside Subdivision Environmental Review Mitigated Neg. Dec Exempt under CEQA Lot size Gross Lot Area 166,835 s.f. same • acres 3 .83 same Average slope(%) -45.40% • Net Lot Area 166,835 x .40= 66, 734 s.f. same Exterior materials: • siding -Stucco • trim -Pre-cast Cone. • windows -Wood/Alum. Clad • roofing -2 pc. Clay Barrel Tile Building nooT area: • first floor -5,433 s.f. • garage -736-400= 336 s.f. • cellar -3,315 s.f. • accessory building 288 s.f. • total (excluding cellar+ -5,997 s.f. /0.089 FAR 400 s.f. garage) House Setbacks (ft.): • front -30ft • rear -30.33 ft • side -199.08 ft • side -22.Sft. House Maximum -18 ft height (ft.) REQUIRED/ PERMITTED RECEl 1 fl ED 'Z 7 -.:S :;1 4-\ UUL /. 'i j TOWN OF LO~ n1 A••••• ,_ -_,.,,. .... -- Required Performance Standards Mitigations per PD 40,000 sq . ft. min. 6000 s.f. max + 400 s.f. garage - 400 s.f. exempt cellar exempt No kitchen 6,000 s.f. maximum/ 0.089 FAR Max. 30 feet minimum 25 feet minimum 20 feet minimum 20 feet minimum Max Height 18 ft. House is visible EXHIBlT ·'t 2 01 G ATOS ION 'JS Parking garage spaces -3 2min. (guest parking available on Foster) Access Structure Setbacks (ft.): • front -127.75 ft 30 ft. min • rear -25.75 ft 25 ft. min • side -215 ft 20 ft. min • side -73ft 20 ft. min. Accessoty Structure Max. -15 ft. 15 ft. max height{h.) ., Accessory Structure -Less than 15% 15% of lot minus coverage .(%) setbacks( code) Sewer or septic -Sewer - N:IDEVIEIUN W\ArcbitclClllre aid Sile\Fost.a0102-Lol 6\Foola20102-Dll.Shtdoc Town of Los Gatos lliDside Development Standards & Guidelines: Compliance Checklist Adctre.s: ~LW ~- Section Standards & Guidelines Compliance This table contains a summary of the Town of Los Gatos' Hillside Development Standards and Guidelines. Use COMPLIANCE Column to show 'X' ·complies, 'O' -non compliance Put 'NIA' if you do not deem the Standard or Guideline applicable. An o.planatlon should be provided where not In compliance. I Introduction A Vision Development must preserve the natural beauty of the hillsides B Overview Character, sensitiv:ity & constraints for dvpt must be considered. C Goal Sustainable development preserving the natural environment D Applicability All HR and RC zoning districts and Rl with hillside sensitiv:ity. E Objectives HDS&G implements Los Gatos' Vision for hillaide development. F S&Gs Standards must be followed . Guidelines make recommendations. G Relationships Consider also General Plan, Zoning, Hillside Specific Plan etc. H Approval Scope of any hillside project determines its approval process. Il Constraints Analysis & Site Selection A Prior to Building Site Selection 1 Constraints Analysis 2 Consultation with Neighbors 3 Pre-Application Meeting/Staff Consultation B View Analysis )( '?( ~ x " w "'It "It ')(' 1( "' )f 1 Viewing Platforms 1--" -2 Determination of Significant Ridgclines C Selecting a Building Site Sl Locate Buildings within LRDA S2 Preserve Views of Highly Visible Hills S3 Reduce Visual Impact S4 Ridgeline View Protection S5 Preserve Natural Features S6 Avoid Hazardous Building Sites S7 Protect Riparian Corridors SS Protect Wildlife G 1 Solar Orientation 02 Impact on Adjacent Properties G3 Minimize Grading TOWN OF WS GATOS ~ ~~- ')(" """ )C; "( ~~ "'I. ")( l( 7' ~" '""'-\ "2., z.. MAR ~ '.·1 ?017 T'.)';V~ CF'/'~ 0AT0~ :.i:._;;,;.~~"~:~ • .:i :..-. . ./!S:'~ .1 EXHIBIT 8 Page 1 Town of Los Gatos Hillside Development Standards & Guidelines: Compliance Checklist Address: 1A?lo 2 ~0'71'e=b ~ Section Standards & Guidelines Compliance . -.. . -···· . Ill Site Planning A Grading SI Minimize Cut & Fill per Table )(' S2 Define Earthwork Quantities [Access/House/Cellar/Other] ~ S3 Locate Buildings to Minimize Grading .>< S4 No Strip Grading )l SS Grade footprint/access/guest parking/turnaround only )( S6 Restore to Original Topography Q S7 Utilize Contour Grading Techniques J( S8 Restore Vegetation at Cut/Fill Slopes )4. S9 Erosion/Sediment Control Plan [Interim and Permanent] )( '• SlO Grading April -September x B Drainage Sl Runoff Dispersion On-Site :M' S2 Upslope Drainage shall not Impact on Downslope Development ~ S3 Preserve and Enhance Natural Drainage Courses >< S4 New Drainage Channels to be Naturalized [rock/vegetation] 0 Gl New Drainage Channels to be placed in less visible Locations ~· G2 Lining of Drainage Channels is Discouraged [bio-swale] Q G3 Dry Stream effects preferred over Undergrounding of Drainage. >< c Driveways & Parking Sl Locate Driveways to Reduce Grading >< S2 Driveways prior to Occupancy lie S3 Gates set back min 25 ' from street ~ S4 Driveways to receive All Weather surface )( S5 Max Driveway Slope to be 15% ~ Gl Min [single house] Driveway width to be 12' "' G2 Max Driveway length 300'. Turnaround area slope< 5%. ~ G3 Driveways min 20' apart or adjoining. Safe distance from Intersections ~ G4 Shared Driveways : encouraged to reduce grading and impervious ?( GS Driveways located/maintained to ensure good line-of-sight. ~ D Safety Geologic Hazards : SI Site Specific Geologic Investigation may be Required. ~ . S2 Site Specific Geologic Investigation concerns to be addressed ' ,c TOWN OF LOS GATOS P age2 Town of Los Gatos Hillside Development Standards & Guidelines: Compliance Checklist Address: W\02 \7t!?\'E~ BoAQ Section Standards & Guidelines Fire Hazards Sl Locate and Design Structures to minimize exposure to wildfires S2 Provide Landscape (Plan) to create defensible space around home S3 Provide adequate Fire Access S4 Ensure adequare water supply for fire prevention S5 Water suppression available and labeled for fire prior to framing S6 Above ground water storage tanks may not encroach into setbacks. Gl Development should a voi d areas subject to severe fire danger. G2 Selectively reduce Fuel Load inside defensible space G3 Ensure Fuel Sources are discontinuous. G4 Landscape Defensible Space with fire prevention in mind. GS Minimize visibility of above ground w ater storage tanks. IV DeYelopment Intensity A Maximum Allowable Development I Adjust Lot for Slope per Table 2 Verify Max Gross floor area< FAR B Exclusions 1 Cellars 2 Garages up to 400 sq ft 3 Stables that are not fully enclosed 4 Barns (size dependant on lot size: 500-2,500 ft.) C Exceptions to maximum floor area 1 Will not be visible from e stablished viewing p latforms 2 No significant impact on trees, wildlife or movement conidors 3 Minimize grading area to accommodate buildings >FAR 4 All standards and applicable guidelineB are being met 5 Compliance to Title 24 w/ margin of at least 10% 6 Pre-wire fur future photovoltaic installation 7 A min of 25% of hardscape mat. is permeable 8 Include cellar element unless conflicts w/other standards 9 No significant visual impact to neighboring properties V. Architectural Design A Design Objectives 01 Visually blends with natural environment 02 Responsive to site constrains & opportunities 03 Compatible with the ne ighborhood & respectful of neighbors 04 Respect of the rural character of the hillside TOWN OF LOS GATOS Compliance Page 3 Town of Los Gatos Hillside Development Standards & Guidelines: Compliance Checklist Address: ..Z0\0'2. ~ ~Q ,. Section Standards & Guidelines . -~ . . . . - B Design to be neighbor friendly Sl Study site lines: place windows & outdoor areas to maintain privacy Gla Minimize 2nd story windows facing close neighboring properties Glb Orient windows, decks, & balconies to avoid privacy for neighbors G le Screening: solid retaining walls, lattice work, planters: obscure sight lines Gld Limit decks & balconies to 6' depth in privacy areas. G le Use landscaping to screen views to your neighbors Glf Existing vegetation that protects privacy should not be removed Glg Screen noise sources: parking, outdoor activity, mechanical , pool Glh Outdoor activity areas away from neighbors quiet areas (bedrooms) C Design for Sustainability SI None G 1 Energy conservation & water saving techniques above min req of Ti tle 24 G2 .a <3,500 sf incorporate a variety of green building strategies + mat. G2.b >3,500 sf -incorporate additional energy+ resource saving features Q1. Design for solar (space & water) & utilize natural cooling & lighting G4 Materials: use less natural resources ; non-toxic ; salvaged or reused . D Design for fire safety S 1 Structures shall be designed to maximi ze protections from wildfires S2 Roofs shall have a Class A covering or Class A roof assembly S3 Eaves & soffits: exposed underside -noncombustible or min I -hr resist. S4 Gutters & downspouts: non combustible material SS Exterior walls : -noncombustible or min 1-hr resist. S6 Under floor & deck: enclosed to gmd -noncombustible or min 1-hr resist. S7 Attic + vents covered w/corrosion-resistant mesh not to exceed 1/4" SS Automatic fire sprklr installed per National + Fire Depts Standards S9 Roof skylights shall be tempered or have multi-layered glazing G 1 Exterior windows should be tempered glass . G2 Minimize windows on side of house exposed to an approaching fire G3 Design roof eaves with minimal overhang for heat & flames E Building Height S 1 Max height for hillside areas is 25 ft S2 Max overall height <35 ft.; <28 ft. if visible from viewing platform S3 Ridgeline & visible homes shall not exceed 18 feet above grade S4 Main level FF, excluding cellar, < 4 ft above existing grade SS Three story elevations are prohibited TOWN OF LOS GATOS Compliance x Page4 Town of Los Gatos Hillside Development Standards & Guidelines: Compliance Checklist Ad~: 4-0·\ Otl.. ~ WAO Section Standards & Guidelines F Minimize building bulk & Mass Sl Minimize bulk, mass & volume, from distance or surrounding propenies S2 Design to conform to natural topography of site & run w/contours. Gl.a Keep building fonns simple G l.b Avoid architectural styles that are viewed as massive & bulky Gl.c Minimize square footage Gl.d Minimize volume; avoid large volume buildings Gl.e Avoid ovemanging decks, staircases, & patios formed by retaining walls G1 .f Step the building foundation & roofs with natural slope G 1.g Use horizontal & venical building components to reduce bulk. G 1.h Create light & shadow w/ modest overhangs, projecti.ODB,alcoves,offsets G l.i Vary elevations, stepping back second stories to conform with topo G 1.j Use below grade rooms. Use landscape & grading to reduce bulk Gl.l Use vaulted ceilings rather than high walls+ attics to achieve 'volume' • G Roofs Sl Small [roofs, lines, components] to reflect irregular natural features S2 Slope of main roof to be oriented w/diicction of natural terrain G 1 large gable ends on downhill elevations should be avoided H Architectural elements SI Enclose w/ walls: ext struct. supports, under firs & decks S2 Skylights to reduce night glare. No glazing on large dome-style S3 Arch detailing on all sides. G 1 Minimize large windows & glass doors to prevent glare G2 Avoid massive, tall elements, 2-stmyentry, turrets, large chimneys I Materials & Color SI Minimize contrast between manmade buildings and environment S2 Exterior colors not to exceed reflectivity of 30 & blend wlvegetation S3 Variety of dark earthtone roofs that blend w/tbe environment S4 Should use copper on exposed metal surfaces or a paintable surface SS Contrasting color accents kept to a minimum G 1 Mat, textures, details used to mitigate visual impact of large wall areas TOWN OF LOS GATOS Compliance Page5 Town of Los Gatos Hillside Development Standards & Guidelines: Compliance Checklist Address: IJ.o \O?-~R.. ,ROAO Section Standards & Guidelines -·· V. Site Elements A Fences and Walls S 1 Min use of walls & fences. Maintain open views, rural +natural char. S2 Fences & walls shall not exceed 6' in height S3 Solid fencing mat shall not be used unless needed for privacy S4 Deer fence max of 8' & limited to omamentaJ landscaping. S5 Fences not to impede movement of wildlife S6 Temp construction fencing limited to building envelope Gl Wood rail-type fences and gates prefetred G2 Chain link fences strongly discouraged G3 Chain link dark color, vinyl & supported with wood frame G4 Open fencing located within 20 ft of property line adjacent to street GS Fences should follow topography B Driveway Entries Sl Blend w/ natural environment & maintain rural character of hillside S2 Entry gate set back from edge of street 25' S3 Direct lighting at entries downwards & not visible from street S4 Display street address to be visible from street at driveway SS SCC Fire Dept to approve electronic or locking entry gates G 1 Entryway gates and fencing should be an open design 02 MonumentaJ entry gates are strongly discouraged C Retaining Walls Sl Use to substantially reduce amount of grading S2 Use natural stone, stained coocrete, or tex surface if visible from street S3 Retaining walls & planters setback; or buffer of 5' adjacent to street S4 RW blend w/natural topo, not run in straight direction >50' SS Landscape adjacent to RW with native trees+ shrubs to screen wall S6 RW constructed of permanent materials (stone, concrete, etc) not wood -D Outdoor Lighting SI Outdoor lighting conform w/fown Zoning Ordinance S2 Not visible/glare to neighbors, low level, directed downward S3 Unshaded OI' non-recessed spotlights are prohibited S4 Decorative only lighting prohibited. No uplighting of trees SS Lighting for sports courts prohibited 01 Use of energy-efficient lighting is encouraged 02 Outdoor lights above 4' should use cutoff fixtures TOWN OF LOS GATOS Compliance Page 6 Town of Los Gatos Hillside Development Standards & Guidelines: Compliance Checklist Addre.ss: _4o_l()'2., £o5iE.R_ ~ Section Standards & Guidelines E Accessory building, pools and sports courts S 1 Accessory building have the same setbacks as main building S2 Acc. buildings integrated wltopo + use similar forms, color.s,materials S3 No sports courts or pools on slopes greater than 30 percent S4 New caretaker units allowed when in compliance with the following: S4.a Necessary/desirable to provide maint or services to property/facilities S4.b The lot is large enough to support second living structure S4.c Maximum floor area for caretaker unit -900 sq ft S4.d Architecturally compatible w/main sttucture S4.e Lot is not part of a Planned Development G None F Impervious Surfaces S None GI Minimize impervious. Use pavers, natural stone in sand, decomp. granite G2 Run off directed away from native trees and shrubs VIl Landscape Design A Landscape design concepts S l Maintain natural appearance of hillBides S2 Design for fire safety. Min vertical clear 13.S' over acc. roads & drive S3 No formal landscaping. Use native species indigenous to immediate area S4 Formal gardens + turf areas limited to areas adjacent to house SS Irrigation design to conserve & protect existing native vegetation S6 Plant selection: water conservation, fire resistant & erosion control S7 Plants > 30' from primary house indigenous for immediate natural habitat G 1 Amnge in random, informal groupings. Blend with natural hillside · G2 Use to control exposure to sun and winds G3 Use to control erosion, screen bwlding, privacy, create sh~ G4 Minimi:ze use of impervious swfaces -use decomp granite, pavers in sand GS Avoid landscaping adjacent to street, driveway entrance, trails G6 Plant trees & flammable vegetation 30' away from home TOWN OF LOS GATOS Compliance u Page 7 Town of Los Gatos Hillside Development Standards & Guidelines: Compliance Checklist Addre.u: ~Ol 0'2.. ~ta_ ·\"0&0 Section Standards & Guidelines -•·. -.. -... -·--- B Plant Material SI Select native species that arc adapted to climate & soil char. of site S2 Ornamental landscaping no more than 30' from residence. Discouraged S3 No spreading plant that will change the character of the hillside S4 Turf grass & high water using plants are prohibited Gl Drought tolerant, water conserving, fire resistant, erosion control G2 Adaptable to climate & soil conditions of site G3 Trees & shrubs should be selected from Town's list G4 Plants adjacent to street & visible from public areas -Use Town's list G5 Native shrubs for large slope plantings D Tree Preservation S 1 Existing trees shall be preserved & protected S2 When trees may be impacted by development, include tree info on plans S3 Visual impact of tree removal shall be submitted with plans S4 Pruning to be consistent w/ Best Management Practices G 1 No grading/constructing within drip line of an existing tree G2 Limit pruning of existing trees G3 Minimal pruning permitted for construction clearance 04 Can remove branches up to 3" in dia for emergency situation VIII Subdivision and Planned Development Projects A Pwpose and intent: to reduce hillside impacts. B Applicability of standards: PD applications in hillside areas C Least restrictive development areas (LRDA) SI Preserve open space and significant natural features . Develop in LRDA S2 LRDA = below ridge view; outside riparian areas; slope < 30%; min impact. S3 Map LRDA (Sub-areas 2-9). Development outside LRDA is a last resort. S4 Sub-area 1: LRDA is identified in Blossom Hill open space study. D Exceptions to development within LRDA 1 Compliance w/ HDSG, Hillside Specific Plan, General Plan 2 Minimal grading, tree removal, landscape changes & more advantageous. 3 Development inside LRDA needs driveway outside LRDA 4 Project Visibility from viewing platform < if inside LRDA E Development standards and guidelines 1 Site Preparation St.a Min grading. Visually blend with adjacent natural areas Sl.b Elevation plans to show existing natural grade and proposed grade Sl.c Avoid sharp cuts & fills, long linear slopes that have a uniform grade TOWN OF LOS GATOS Compliance u Nib. Page 8 Town of Los Gatos Hillside Development Standards & Guidelines: Compliance Checklist Address: "2cl02. To~ BoA2 Section Standards & Guidelines Compliance G1 Avoid grading in areas where slope is greater than 25 percent .. tA G2 Avoid pad & terrace grading. j 'V ..... 2 Drainage S2.a Upslope development shall not negatively impact downslope drainage S2.b Natural drainage course shall be preserved Gl.a Terrace drains, use landform slope. Down drains-least consp location G 1.b Native rock foe drainage channels & brow ditches ,, 3 Lot configuration and building locations Sl Layout/plan to adapt to existing topo S2 Offer a variety of lot sizes & shapes influenced by topo S3 Preserve open space, protect natural features, reduce repetitive designs S4 Indicate Building footprint on grading plan & staked on site SS Mfct'd slopes located on uphill side of bldgs; hide slope behind bldg . G1 Preserve environmentally sensitive areas, natural features, open space 4 Street layout and driveways Sl Street & drainage shall reflect rural character, natural features Gl Streets, drives, parking, emerg. veh. access be aligned to existing grades G2 Joint driveways will have street addresses for all resid. Using driveway G3 DW approach located to max on-street parking 04 Limit road lighting to intersections, curves, dead ends, multi-use parking GS Road & driveway graded banks-plant with grasses & native trees & shrubs s Trails Sl Plans must be reviewed wffrails section of Town & SC Cty General Plans Gl Trail easement dedication & construction shall be a condition of approval G2 Design trails for multiple use G3 Form CC&R's or maint. Districts ao trail expense will be borne by HO's G4 Locate away from existing residential are as GS Cross -country type trails should ~ developed G6 Place trails in dedicated open space + though trees and scenic areas G7 .a Limit trail use to pedestrian, bicycle, and equestrian use only G7.b Prevent use by all motorized vehicles G7.c Protect the natural environments G7 .d Promote safe recreational use G7 .e Determine appropriate width G7.f Establish policies regarding fencing location & type G7.g Incorporate erosion control measures TOWN OF LOS GATOS Page9 This Page Intentionally Left Blank April 10, 2017 Ms. Erin Walt:e.t:s Community Development Department Town of Los Gatos 110 E. Main Street Los Gatos, CA 95031 RE: 20102 Foster Road Dear Erin: ARCHITECTURE Pl.ANNING URBAN DESIGN Rt:CC:~v-D ~-I '-t-' z.. "2-. APR 1 0 2017 TOWN OF LOS GATOS PLANNING DIVISION I previously reviewed a project submittal for this site in 2005, and have reviewed the two homes across Foster Road from this site My comments and recommendations are as follows: Neighborhood Context The site is located on a graded flat plateau accommodating four parcels of which this lot is the umllcst. Two of the lom have been developed with one-story homes -sec aerial photo on the following page. I also recently reviewed the design for a proposed one story home on the remaining undeveloped parcel. 700 LARKSPUR LANDING CIRCLE. SUITE 199 . LAR KSPUR . CA . 94939 EXHIBIT 9· TEL: 415.331 .3795 CDGPLAN@PACBELL.NET The Site and Existing Homes Concerns and Recommendations 20102 Fosret Road Design Review Comments April 10, 2017 Page 2 The proposed house is one-story in height and very well designed -see proposed floor pbn, elevations and site sections below. CANNON DESIGN GROUP 700 LARKSPUR LANDING CIRCLE SUITE 199 LARKSPUR CA 94939 "' '" .. .. "' "" "' "' .... "' Proposed Longitudinal Section = i Proposed Section through Foster Road Proposed Front Elevation Proposed Rear Elevation ; -...... ·-- ---- 20102 Fosiu Road Design Review Comments April 10, 2017 Page 3 .. .. . .. ... "' ,. ,. "' "' "' Proposed Right Side Elevation (Visible from Foster Road) Proposed Left Side Elevation CANNON DESIGN GROUP 700 LARKSPUR LANQING CIRCLE . SUITE 199 . LARKSPUR . CA . 94939 20102 Foster Road Design Review Comments April 10, 2017 Page 4 The proposed design is similar in scale to the current homes across Foster Road. I b elieve the home will fit well on this site and is consistent with the Town's Residential Design Guidelines. I have n o recommendations for changes. Erin, please let me know if you have any questions, or if there arc other issues that I did not address. Sinccrdy, CANNON DESIGN GROUP Larry L. Cannon CANNON DESIGN GROUP 700 LARKSPUR LANDING CIRCLE SUITE 199 LARKSPUR . CA 94939 ~ "-" \._ I :; .... 0 n -~Jh Walter Levison r CONSULTING ARBORIST A~ -=.om:z:. ASCA Registered Consulting Art>orlst#401/ ISA Tree Risk Asaeasment Qualified/ ISA Ceitlfled Arborist #WC-3172 cell (415) 203-0990/ drtrae@sboglobal.net Site Add,_: 20102 F08W Road, Los G91oa, CA Assessment of Protected-Size Trees at and adJacent to 20102 Foster Road, Lot 6 Los Gatos, California . Prepared for: ·Ms. Erin Walter$, Associate Planner Town of Los Gatos Community Development Department 110 E. M'ain Street Los Gatos, .CA 95030 Field Visit: Walter Levison, Contract Town Arborist (CTA) 1/8/2016 Report by CTA Version: 1/8/2016 1 of31 Rsglstlind Member, Anmtcan Society of Consultng Arbcmls and .._,,_ of '1a l:i181M1onal Society cf Art>ortaAn C Wlllliar Lav*ln2015M Rl~ts ~ RECEIVED ~-\c...\-'Z. -z. JAN 13 2016 IO'M'I OF LOS GATOS PLANNING OlVISlON }EXHIBIT 1 0 Version: 1/8/2016 ~h Walter Levison .r CONSULTING ARBORIST : .. ~ ~-m:.:;. ASCA Registered Consulting Arborlst#401/ ISA Tree Risk Assessment Qualified/ ISA Certlfted Arborlst #Wc-3172 cell (415) 203-0990/ drtree@sbcglobal.net Table of Contents 1.0 Summary 3 2.0 Assignment & Background 4 ! 3.1 Maintenance & Protection Codes from Tree Data Table 9 4.0 Tree Location & Protection Fence Map 10 5.0 Observations & Discussion ! 11 i 6.0 Town of Los Gatos -What Trees are Protect~d? 13 7. O Recommendations : 15 I . 8.0 Tree Protection and Maintenance Directions ~r Town Code 20 9 .0 Tree Replacement Standards-Los Gatos To\Nn Code 24 10.0 Author's Qualifications 26 11.0 Assumptions and Limiting· Conditions · ''"' · · 27 12.0 Certification .··. 28 13.0 Digital Images 28 -~;:~\.~,:' 2 of31 Sile Add,_: 20102 f'9'lar Road, Los Glllm, CA vnon: 11!12018 ' Regl..., Men'Mr, Amm1can Scdety of Consulling Alborl8lll and ManH" of Ille ~ Scdetyof ~ 0 WllW LM<llon 2015 NA RigllC8 ~ '- '- ' Walter Levison CONSU LH N G ARBORIST ~\. ~-=:.::-. ASCA Reglst.eted Consulting Arborist #401/ ISA Tree Risk Asseament Qualified / ISA Certified Arborist #Wc-3172 cell (415) 20~0 I drtiee@sbcglobal.net 1.0 Summar)' 1. Protected-size trees (4 Inches diameter at 4.5 feet above grade)-to be removed· due to direct and/or Indirect conflicts with proposed work: None. 2. Protected-size trees that may be significantly impacted by site plan-related work as currently proposed. See 'observations and discussion section 5.0' for details of various site work elements and their expected impacts on these ·trees: a. b. c. d. e. f. g. Coast live oak #1 Coast live oak #2 California bay laurer #3. coast live oak #4: Blue oak #6 (large protected tree L:PT status). Species sensitive to oonstruction pressures. Blue oak #7: Species sensitive to construction pressures. Blue oak #8. Species sensitive to construction _pressures. 3. Protected-size trees that can be retained wfth.no imp.$ctsexpected, lfprotectlve ·measures are Installed per the recommendations below m·thls report Large protected tree (LPT) #5 (California bay laurel). 4. Other Notes: Tree tags were in many cases not able to be affixed to survey.trees, and trunk diameters were estimated visually from afar due to site inaccessibility (e.g. thick poison oak presence, etc.). Diameters are •·estimated" where nc;>ted in. the tree data table below m _section 3.0 '. Trunk locations for trees #3-, 4, 5, 6, 7, and#8 were "rough plQtted"by the .CTA uslni.a Nikon F~restry Pro hypsometer/rangeflnder device. The CTA sugg~sts that tlie applicant provide Staff with-accurate sutveyor-plotted locations for these trees (oak #4 appeared to be incorrectly plotted at the west side of the.existing energy dissipa~r. and ~$."moved by the CTA on '1e below tree map as its actual position in the field !s east of the dissipater spillway). · Site Address: 20102 Fo9lllr Rmd, Loll G-. CA Regltfered Member. Amalan Sodely 0( ConlUq Afborlatl and Member 0( IMt I~ Sodely 0( ArbadcU1Ure Cl W111at Levison ~5 M Rl!lhts Raaar...cf 3of31 Veralcn: 1/8/2016 ~h Walter Levison rl CONSULTING AABORIST M\ ·==· . .::~,, ASCA Registered Consulting Arborist #401/ ISA Tree Risk Assessment Qual111ed / ISACertlfied Arborist #Vt'C-3172 cell (415) 203-0990 I drtree@sbcglobal.net 2.0 Assignment & Background Walter Levison, Contract Town Arborist (CTA) was directed to tag with numbered alumimm tags and assess all Protected Size (4 inch diameter and greater) trees both on the property proposed for site plan work and adjacent to the site plan area within 1 O linear feet of the property lines. Note that "exception• trees not protected under the current Town tree ordinance (e.g . fruit and nut trees <18 inches diameter, and Tasmanian blue gum, red gum, blackwood acacia, tulip tree, tree of heaven, palms (except Phoenix canarlensis), and privet <24 inches diameter, etc.) were .!lQ.1 tagged or assessed by the CTA. On "Hillside• properties (see Hillside map , this page), all eucalyptus species are considered exception trees, and are not protected by Town ordinance provisions. Large protected tree (LPT) means any oak (Quercus), California buckeye (Aescu/us californica), or Pacific madrone (Arbutus menziesii) which has a 24 inch or greater diameter (75 inch circumference); or any other species of tree with a 48 inch or greater diameter (150 inch circumference). Trunk measurement in the case of a multiple stem tree is the . sum of all mainstem diameters. ! . ....-. -~ ·----~~. ~ .......... ~ r ...... ~ • l •. ~ ' . •• : ' ----j --_,_1 ....... ..J..-'--.. -· --~ .... .__1 ... Side Note: Please view digital versions of this report using Adobe CS, Adobe Pro, or equivalent software programs, since use of a free Adobe acrobat reader product may cause color-coded items in the author's tree map to disappear from view. Valuation Appraisal and Security Bonding The new 2015 iteration of the Town tree ordinance section 29.10.1000 (c)3 includes wordage that requires that all trees being retained on a development site need to be appraised for dollar value at the applicant's expense prior.to building or grading permits being issued by the Town. The CTA has therefore included this appraisal information In the following report for use by Town planning division Staff. · Part 'f of this same tree ordinance section states that the Town may condition a security bond prior to issuance of a permit, in the sum of $5,000 per each tree being preserved, or $25,000, whichever is less. The ordinance does not contain wordage as to whether this includes neighbor-owned trees adjacent to construction . Therefore , the CTA will assume that neighbor-owned trees are included as trees "required to be preserved". The CTA will determine a security bond amount based on the above wordage and on the appraised values of the trees being retained on and adjacent to the proposed development site. 6118 Add,_: 20102 Foa.r Road, Loa GellOI, CA ~ Mllmler, American Society of Conaulllng Albol1m .ml ~ of the lnllr11111ion81 6ociety of ArbollaAn 0WtJl/ttlll..alllllon2015M~~ 40!31 Venion: 11812016 J I z Ill ~ i 1 2 ' Walter Levison CON~ULTING ARBORIST ASCA Registered Consulting Arborist #401/ ISA Tree Risk Assessnent Qualified/ ISA Certlfted Arborist #W~172 3.0 Tree Data Table I I I .Ill :Ji ' .. 11 ···-(: ... · I '1 c: I ~. Overall Condition a.i~i Gillnua& Common i5 ~--1 iiw Specie• ..... c Q 'Si 'J~ Rating Ii ~ I E a. :z: g (Ot.o100'1ij j ~~ c: c: !c. ~ 2 ~ f"' e ' . ... :z: -.;. Querws Coastllve 11 10 -21 2Bl'l5 9Qf75 85%Good No agrlfdle oak Querwa Coast live Est --11 28l2S 90/80 87%Good No agrifa'/a Gell 11 !i cifll1 Site !\CldreM: 20102 Foalar Road, Loe GlllOI, CA RegtS19red Member, American Sodel)' of Conaullng Arborlsts and Member of Illa intmmllllonal Sodel)' of AltloriWlunl C W•H• Levison 2015 Al Rights~ I ~ I ,. x x M\ ·=!~..::..~ cell (41 5) 203-0990/ drtree@sbcglobal.net ·,1~1 II t_ I ~ z ·~ U1 Ii ,, .... a "a. i. -~a~ fill~~ ~& a: c:; .15 ;ou -: ' j1I~ ~~~ ·1'°1 i::a "I ~i~~ii .I jii :!!! • i ~ c~~ J! c 'D 11:1 ~ a:z i If ~ c; D. IL Ir Good TOE. Minor to 100% llw aown ratio, Mcdarate with canopy (Retaining that sxtends waUand to ground. road Canopy can 15feet TB,RPZ grading radius be protected through by use of a uphlll side dlaln link of root fence and zone) lilt fence "wall". GoodTDE. 100%11va aown ratio, wl!hcanopy lhat extends to ground. Canopy can 10fllet be partlally radlus(or Mcderateto pnllllcted by moralf use of a grading 1evara chain link (ro.d '9nceand plan 11 grading and sit fence adjusllld retaining "Wall"' but to move wall wiil need to retaining TB, RPZ. P construction be sheared wall within 90Ulh at10feet farther side of out from south canopy In.Ilk fll'll, to 1han dr1pllne) clllar the currently proposed propoeecl area where the n1teining wall and Rllldway will encroach 1nlo the dr1pllne. Version: 1/8/2016 l E :::J z ! ~ I- ' 3 4 5 ~h Walter Levison r CONSULTING ARBORIST ASCA Registered Consulting Arborist #401 / ISA Tree Risk Assessment Qualified / ISA Certllled Arborist #VVC-3172 .. I .. .M f-r .... I '1 I I ~i .. 11 Ownill I I J • it i;• Genus& Common c.>-Condition Q ~. .. 1 111 SpKlea N ...... li s:I Sl Rltlng ~.... i '&_ i.t (Oto 100%) c ~ c ~c J f':::J ~ ~ :z: "' ~E California Umbelutana bay laurel Est. Est E&t ca/lfom/ca (not plotlllld 6 5 5 20+ 25125 75175 75%Good No on appllcant sheet) Quercus CoastHve Est. agrlfdla oak 18 --18 45130 85/80 84%Good No CatlfOmla UmbeRularlll bay laurel Est. Est Est Est ca/ifom/ca (not plotted 10 9 8 60+ 30/46 85/80 82%Good Yee on 81)plicanl . sheet) 8of31 Site Add1'81115: 20102 Foster Road, Los Gatos, CA Raglatarad Membw, American Society of Consultin11 Alborlsts and ...,,.., ... or the lnt.mllional Soclaty aJ Arboriwiur. 0 Welter lJwllOll 2015 AH Rights ReallMld I I I• x x x A ··-··-"le'-..... cell (415) 203-0990 I drtree@sbcglobal.net "a i!i:C' I ~ z• l~h '5 ti~ I! a c-J Ii 1111 g2 f.:ii;r: ~1 II r~ii ih 11·1 1;; r i~rJ lt. I 1J! l1S '!-ii a::z ! E i'fll II.Ill .§ ~.s. II. Moderate to good TOE . 100%11ve Moderate to crown ratio , Sevani so canopy (depending reaches 10feet on how new grade. May radius TB,RPZ. P Stolm drain require pipe Is pruning to Installed} clear a tool prolllctlon zoner.nee route. Location of Minor to Irle Severe adjusted by (depending 1heCTA 10 to 15 on how new based on feet TB,RPZ stosm drain the current radius pipe Is loca1lon of Installed) the en111gy dlslllnafer. Minor Tree 11 (depending loceted on on where St Joseph'• lnlgation Hiii Preserve land, with 40feet pipe trunks at radius trenching approx. 45 (I.e. occurs for feet from along the RPZ new tree ln111lllation cabana and property between canopy llne) cabana and drtpl lne canopy of approx. 20 faetfrom this tree. cabana. Verlllon: 118/2018 .l E :::t z ' ! 6 7 ~h Walter Levison r CONSULTING ARBORIST ASCA Registered Consulting Arborist #401/ ISA Trse Risk Assessment Quallfted / ISA Cettlfied Arborlst #WC-3172 I I .. .II: t I!': ri t ~I oz :p :i: I I I Se:. •cl! Overall · i~i Genus& earn-iS "1 i11 C•ndltlon Species ...... D ~ :Ii I J c l! a. (0lo100'1') J g~ ~ g f m . ' . OJ :z: ... , ...... ~.-... Querc.Js E9l Est douglad Blue oak 13 13 -26 35/50 75175 75%Good Yee Querws Est. douglasll Blue oak 15 --15 35135 75175 75%Good No 7of31 Site Ad-: 20102 Fonlr Road, \..oe GUiii, CA Regislerecl Memblf, Am111e11n Society of Consulllllg Artlotlllts and Member of the lnmrn.tlon•I Socaty al AltJortc:Uture O Waller Levison 2015 Al RIQh1s ~rwd I I .~ x x M\ .~=-=·~ .. cell (415) 203-0990 I drtree~lobal.net ,~ ,_ ~ z~-1 ~11 1i~ J 11 UH i iC ,f -s BU• 11 !j J1•1 g ti l u ! ,, I J!i m Ii a. iri j.S. " 'IL Moderate to Severe Impacts expected, (depending on whether we can ellmlnate proposed boulder 151inear rfprap feet Installation radius within 15 down Iii RF'Z feat of trunk, and from 1nm1nn INnk. propoled l•nd-pe plantllree.' irrigation pipe lns1allatlons within 20 f'eetc:i trunk. uvecrown ratto50%. Mlnorw . Severe Impacts expected, depending 15 Unear on whether feet we can radius eliminate downtil RPZ landscape pllntlng• from and -· trunk lnlgmlon pipe trenching within 20 feetc:i trunk. I Verwlan: 1Jlll2016 A Walter Levison t'l(I CONSULTING ARBORIST M\ . =!:·::..:~-;:~ ASCA Reglatered Consulting Arborlst #401/ ISA Tree Risk Assessment Qualllled /ISA Certified Arborist #WC-3172 cell (415) 203-0990 I drtree@sbcglobal.net .. .. I I .. t .. f 1 J'I '>lit f-a-•-.! I c I f 1 J 111• z"' tft1 fi ~i o-I h oii! I c~ C>Yerall ~1 11 ii!i z Genus& Common i3i ;l !Ji Condition i~i 1.121!: ifi !~s ! st-... ...,. :i. si ! ~.i Rllltng t"'I 1:; ~ ja (Oto 100%) j I='' ii J ' iJ ! ..... c ~ i '"' :z: ~E .s .s. 6 m f ~ ~ f Canopy lopeldad southwest. Again, Impact severtty depends on whether we can keep el 15to20 new Hneer landscape feet 8 Quen:us Blueoek Est. --13 30/30 80/40 60% Fair No x pl8nU!VB South radius RPZ doug/88il 13 end -wast downhlll lntgatlon from pipe lrunk lnlnchlng at least20 llnaarfaet cu from trunk by redesigring the proposed plan acconllnnlv, NOTES ON TREE SURVEY DATA TABLE: 1. On-site survey trees include all existing specimens of tree species with at least one (1) mainstem measuring greater than or equal to 4 inches diameter at 4.5 feet above_ grade. 2. Multi-stem tree diameter is equal to the total of all mainstem diameters at 4.5 feet above grade, per the Town tree ordinance definition of "diameter". Diameters were determined using a forester's •0-tape• which is wrapped around the circumference of the tree, and converts circumference to diameter inches and tenths of inches. 3. Heights and canopy spread diameters were estimated visually for smaller trees. Larger specimen tree heights were determined using a Nikon Forestry Pro 550 digital hypsometer/rangefinder device. 4. (If applicable) Trees with thick poison oak surrounding their trunks were avoided. Those specimens were not tagged with numeric tree tags, and trunk diameters in those cases were visually estimated from afar. TD/E = "Current season live twig density and live twig extension• Siie Add,_: 20102 Fo9l8I' Road. loll Getos, CA ~lllldd Mlrrl>er, Amem:an Society of Consulting ArbOllsfll and Member of the lnlemdonal Soc;iety of ArbOllC.-IUre O W8119r ~on 2015All ~Is Res8lll9d 8of31 Version: 1181201 B ' Walter Levison CONSULTIN.G ARBORIST <~ ~t~ -·-~ ASCA Registered Consulting Ai:borist #40f/ ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WC-3172 cell (415} 203-0990 I drtree@sbcglobal.net 3.1 Maintenance & Protection Codes from Tree: Data· Table RPZ: Root protection zone fel"IOe, c:M.lnJir:i.k, with 2"' diemeter iron~ ctnven24" rntq tM. ground,. 6 to 8'.feet Qn·center mall.. spacing. . .. . ' . . RB: Root buffer consisting of wood chipmulch lain ov'er exiStlng soil a& ai 12 Inch thick layer, overlain with 1 inch or greater plywood strapped together with metal plates. This root buffer or soJI buffer should be placed over the;~re width of the construction corndor between tree trunks and construction. RP: Root pruning. Prune woody roots measuring greater than or equa.1 't0 .1 inch diameter by carefullyback~igging Into the son around each root using small hand tools until an area is reached where the root is undamaged ~ Cleanly cut.through the root at ·nghtangle to .the root growth direction, using professional grade pruning equipment and/or a ·Sawzall .with 'M>Od pruning btade. ~II around the .cut root imtnediately;(s8me day). end 1horoughly Irrigate the area to L I saturate the uppermost 24 Inches of the soil profile.; . ~ BDRP: Back-dig root pruning: H8nd-d1g around the broken root, digging horizontally into the open soil root zone until adean. unbroken, unshattered section of the root is visible. Proceed as per '.root pruning'. _ · · . .. . TB: Trunk buffer consists of 20-40 wraps .of orange plastic snow fencmg to create a 2 inch thick buffer over the IOwest 8 feet of tree trunk (usually takes at least an entire roll of orange fencing}~ Lay 2X4 wood boardl wrtlcaJly, side by sid~· around the entlr&. circumference of the trunk SEl::ure buffer using duct tape (not wires). · · · · F: Fertilization with slow-release Gr:eenbelt 22-14-14 tree ·formuta; as elthera soil dr~ .over the ropt ZPne or using a fertilizer injection gun. This brand and formulation is commonly used' by reputable ·tree care companies 1n the -Bay Area. · M: 4-inch thi ck layer of chippertr.uck type .natural~ chips (exampte $puree: Lyngso GSrden Supply, self piek.:.Up).'Do not use bark chips or shredded redwood bark. · W: Irrigate using various methods tO be determined ~ugh (iti'~ssiof. with General Contractor . lmg,tion f.nlquency and duration to be determined through discussion. · ... P: Pruning per specifications nOted ,elsewhere. AU pruning must be ~rfonn~d only under direct site supeMsion Qf an ISA Certil1ed Arborist, or performed directly by an ISA Certified Afbe>rist,· and shaU cOnfotm tO all Cl:l.mmt ~S1 A300 standal'.ds . · MON:.A Project Arbortst must be present to mqnltOr specific.,work as ·noted for each t~e. 8119 Addniee: 20102 ~ Road , Los Gatos, CA Reljlatared ......,_, Amerbn Society of CClnlllllilll lllbolllls end Member of Iha lntlmlllcNI Sociely cf Mlortcillure Cl Wnttar Levison 2015 All Rights Rasan.ed 9 of:S1 Varalon: 11812016 ~h Walter Levison rl CONSULTING ARBORIST &\ .~~m.:.?'~t .. ASCA Registered Consulting M.lorist #401/ ISA Tree Risk Assessment Qualified/ ISA Certified Arborlst #WC-3172 cell (415) 203-0990 I drtree@sbcglobal.net 4.0 Tree Location & Protection Fence Map The CTA rough-plotted many of the above tree locations. The CTA therefore suggests having the applicant's survey team verify the locations of trees #3, 4, 6, 7, and #8 so that we know exact distances between tree trunks and proposed work. Note that tree #4 appears to be incorrectly plotted on the applicant's sheet as being west of the existing energy dissipater. of31 Sile Addr9ss: 20102 Fosler Road. Loll Getos. CA ~ Mlntl«, Mwlc8n Soaety or ConeultnO MIOrt8lll end MerrOer ot Ile 1n11m.ocna1 SOCiely or M>oria.llue 0 Wlllllr Levison 2015 M Right.~ Vllllllon: 1/812018 ~h Walter Levison r CONSULTING ARBORIST A:\ .~:r~"t:~. ASCA Reglstenld Consulting Arb0tist #401/ ISA Tree Risk Assessment Qualified I ISA Certified Arborlst #N/c-3172 cell (415) 203--0990 I drtree@sbcglobel.net 5.0 Observations & Discussion The CT.A reviewed the entire set of plans submitted to planning division (received by planning dept. 11/30/2015, except for the landscape plan which was re~ived In January 2016). Comments regarding proposed work noted on lndlvldual plan sheets are detalled below: a. Sheet L 1: Sheet L 1 dated 1 /11 /2016 by Jenna Bayer Garden Design, Inc. of Mountain View, California shows a large number of new plantings to be installed on the hill between the proposed new residence and native blue oak specimens #6, 7, and #8 (see tree map scan in this report). The plantings do extend up to approximately the 727 foot elevation ASL contour, which places them Within the canopy driplines of the trees and very close to the trunk locations which are preliminarily shown at between 727 and 731 feet elevation ASL. It is assumed that new irrigation piping wjll either be flex tubii,g placed over grade, or solid pipe trenched into the ground, as a water dellvery system for proposed new plantings. The locatfons of the oak #6, 7, and #8 trunks is subject to further survey by the applicant's team, and at the time of writing they are simply rough approxJmate-plotted by the CTA using a Nikon hypsometer, keying off of the existing site story poles as a measurement tool. It Is the opinion of the CT A that the current proposed plan needs to be revised to completely remove all plantings along the southwest slope within approximately 15 or 20 feet of the trunks of the trees, to avoid causing root damage and decline/death of these sensitive native blue oak specimens. Before that revision occurs, I suggest that we have the applicant's surveyor accurately plot trees #6, 7, and #8 so that we know exactly where they are located. b. Irrigation: There was no irrigation plan sheet submitted by the applicant for this project, but from the planting plan shown on sheet L 1, it appears that irrigation pipe trenching will likely affect trees #6, 7, and #8 if the plan Is installed as currently proposed. However, as noted above, the CTA suggests that Staff have the applicant provide us with accurate locations of trees #6, 7, and #8 so that we can determine boundary wi 1:iths and root protection zone fence routing between plantings/irrigation piping and the trunks of these three native blue oak specimens. c. Grading and Drainage: Sheet C-2 dated 10/1912015 by TS Civil Engineering of San Jose, California. • Proposed new retaining wall installation and road grading will occur outside the canopy dripline of coast live oak #1 , which will allow us to-set up a root protection zone "wall" of chain link fencing with silt fence and straw wattles pinned down along the uphill side of the fence at 15 feet min. offset from the trunk (see tree map mark~up below In this report). • New retaining wall work and road grading will occur within the south canopy dripline of coast live oak #2, reducing the available area south of trunk to only 10 feet or less as a root protection zone fenced area. This means that the tree Will need to be sheared or otherwise pruned to reduce its extension southward Into the proposed road and wall building area. TheCTA suggests moving the proposed IR.'1i:ilii51~!L£;~·~ roadway and wall project 5 to 10 feet southward to allow for installation of a root protection zone wall with -· · chain link fence, silt fence, and straw wattles at minimum 15 feet southward offset. from trunk edge. • Callfomia bay laurel #3 was not plotted on the applicant's plan set It is located in a zo"ne .where the proposed storm drain pipe will slope downhill to the existing energy dissipater (see map in this report). The pipe will encroach to approximately 7 horizontal feet from the tree trunk edge. This is unacceptable as an impact to the tree's south side root system. The CTA suggests that the pipe either be relocated to 15 feet southward offset from the trunk of this tree, or that it be placed over-grade as a trenchless system and strapped into a standing steel bracket (see sample image at right which shows the existing storm drain outfall at oak #4 at this site). If the pipe.is placed over grade or relocated to outside _the canopy drlpline, we wlll then be able to preserve the south side root zone intact all the way out to the canopy Site Address: 20102 Fo8lllr Road, Los Gatos, CA Registered Membll', Amarican Society of Conau~ NbOrieta and Member of th• lnlllmallanal Sodwty of MIOllC:Ulunl G Welter Le..;son 2015 NA Rlghta RMeMld ·11 of31 Version: 1/8/2016 ~h Walter Levison r CONSULTING AABORIST &\ ~-==:; .. ASCA Regi~ Consulting Arborist #401/ ISA Tree Risk A&sessment .Qualllled / ISAiCertifted Arborist #WC-3172 ·ceu (415) 203-09901 drtnte@sbcglobel.net dripline. • Coast live oak #4 plot point is for some reason shown on· the applicant's sheets as located to ·ttiewest. of the existing dissipater spillway. However, the actual location of the tree in the field appears to· be-just. east of the spillway. Therefore, the CTA relocated the plot point to, an apparently more accurate location (see tree map in this report). As:with bay laurel #3 ,1tie proposed storm drain :pipe instllllation ·is shown at anon-appropriate location at 7 to 8 feet offset from the trunk edge of oak #4, which precludes are being able to fence off the tree with a root protection zone: wall .of chain link, silt fence, and straw wattle. The CTA suggests that we either adjust the1 proposed storm drain . route to 15 !feet offset from the trunk, or strap it over-grade such that trenching is not required (see above Image of the existinm site storm drain strapped over gn1de as a trenchless install). On a similar note, the existing energy dissipater is built in such a way that the concrete spillway may actually be increasing the velocity of storm drain storm waters discharged into the forest area downhill from the outfall (see image· above on pag~ 11). We may want the appHcant to hand-place additional boulders over the concrete spillway to slow down· discharge and thereby reduce potential soil erosion downhill on this very steep sloped portion of the site and adjacent k>t • California bay laurel #5 Is .a large protected tree (LPT) due toiits multiple mainstems, per Town idefinition. It Is located on St. Joseph's Hill Preserve off the plan sheets at approximately 45 feet from the proposed cabana footprint corner. The canopy extends eastward to approximately 20 feet from the cabana comer point. The proposed landscape plan and grad~ng/drainage plan show proposed Work that extends westward beyond the cabana footprint (e.g. drainage work, plantings, etc.). Therefore, the CTA suggests that we erect a root protection zone of chain Jink along the west property line, which will allow this tree's entire canopy.dripline .arep to ~ protected, and avoid all impacts to the tree. • Blue oak #6 is a large· protected tree (LPT) per Town definitiqn . This tree was rougl\.-plotted on ithe southwest slope area using a Nikon hypsometer, · uphill from the proposed .residence footprint. The location is donsidered approximate only, but from what we can see, it appears that the proposed rip rap slope stabilization work as shown on the grading and drainage plan sheet will encroach to within 6 or 7 feet of the trunk edge. This is too close in tenns of being able to keep. the root system intactdownhill trom the trunk. The CTA suggests that if the proposed rip rap installation involves any earth movement, grading, excavation, etc., it would be more beneficial to oak #6 if we eliminate this work and use another type of slope stabilization that will .not involve any adjustments to natural · soil grade within 15 feet .of the trunk edge. The CTA further suggests that we erect root protection zone fencing at least 15 to 20 feet downhill from trunk (assuming that the proposed landscape plan planting~ and irrigation ean be eliminated within 15 feet of the tree). Refer to the tree map in this report. • Blue oak #7 is rough-plotted by the CTA. As with blue oak #6. this tree wHI need to be fenced·qffwith chain link root protection zone fencing at 15 to 20 feet downhill from trunk (assuming that the proposed landsc~pe plan plantings and Irrigation can be eliminated within 15 feet of the tree). ! • ··.Blue oak #8 is rough-plotted by the CTA .. The tree appears·.td be approximately 20 .feet from oak #7, and has a greater westward offset from proposed site plan work than oak #7. The tree, if fenced off at 15 to 20 feet from trunk, will be easily protected from any damages caused by drainage channel work at the new base of slope per the grading · and drainage -sheet. However, the proposed lan~scapeplan shows a large number of plantings that apparently encroach into the canopy dripline area ancHree root zone downhill from the trunk. T!he CTA suggests eliminating the plantings and any associated irrigation such that we can fence off the tree at 15 to 20 feet downhill from the trunk:. d. Removal Fees and/or Mitigation: No protected size trees are proposed to be removed. Therefore, there are no mitigation fees or removal fees required to be paid to the Town. Sim Add,_: 20102 FOiier Road, Los Galas, CA R8Qiatered ~. Ammlcmi Society of Conlulling Arbollsts .oo Merrber of the lnlemalJorNll society d Arboriw'.11n e w..., UMlon 2015 Al Rigllts RaeM1C1 12 of 31 Ven;lon: 11812016 (_ { -· ~\a, Walter Levison Vf CONSULTING ARBORIST A~ .-.:z:::..-..=.s. ASCA Registenld Consulting Arborist #401/ ISA Tree Risk Assessment Qualllled / ISA certllled Arborist #WC-3172 cell (415) 203-0990 I drtree@sbcglobal.net e. Appraised Values and Security Bonding : The following are trunk fo""ula method dete""ined dollar values for the eight (8) survey trees: 1 . Tree #1 : $3,320. 2 . Tree #2: $1, 700. 3 . Tree #3: $2,080. 4 . Tree #4: $5,200. 5. Tree #5: $10,200. 6 . Tree #6: $7,000. 7. Tree#7: $4,690. 8. Tree #8: $2,660. Total Tree Value: $38,850. Security Bond : The Town tree ordinance contains wordage that allows for the Town to condition that applicants post a tree bond with the Town in the amount of $5,000 per each-tree required to be retained, or $25,000, whichever is less. rn this case, the minimum requir·ed tree bond will be $25,000. 6.0 Town Of Los Gato& ...;. What Trees. are Protected?· Per the 2015 iteration of the .Town of Los Gatos tree ordinance (Town -Code Chapter 29 -Zoning Regulations, Article 1 ), the following regulations apply to all trees within the Town's jurisdiction (wordage adjusted}: 1. 2 . 3. 4. 5. 6. All trees with at least.a single mainstem measuring four (4) inches diameter or greater at 4,5 feet above grade are considered "Protected Trees" when remo\tal relates to any development review. · . . 12 inch diameter (18 Inch multistem total) trees on developed residential property not currently subject to development review. 8 inch diameter (8 lnch .multister:n total) blue:0ak (Quercus doqglas/1), black oak (Quercus kellogi1), California buckeye (Aescu/us californica), and Pacific madr.one (Arbutus menziesi1) on deve1oped residential · lots n~ot currently subject to development review. 8 inch diameter (8 inch· multistem total} b'8e$ on. de~loped residential property not. currently subject to development review, on lots in the designated Hlllslde Area per the offtCial Town map. AU tree.$ with a single mainstem or sum of multiple malnstems totaling 48 inches diameter or greater at 4.5 feet above grade are considered •Large Protected Trees" (LPT). All oak species (Quercus spp.), California buckeye (Aescu/us califomlca),,.and Pacific madrone (Arbutus menziesi1) with one or more mainstems totaling 24 Incites diameter or more af4.5 reet above grade are considered "Large Protected Traes" (LPT). 13 of31 $119 Addreu: 20102 Folml' ~d , Los Glllol, CA· VersiOf': 1/8/2016 Raguared Member, Anwican Sodety c# Conaultlng Atbollsls and Ment>er d Ille lnllmlllion81 Soc:lety of AtboriQJ!lu,. Cl W•l!llr Uwiaon 2015 All Rgllls ~-d ~h Walter Levison rl CONSULT I NG ARBORIST .~ ASCA Registered Consulting Arborist #401/ ISA Tree Risk Assessment Qualified/ ISA Certified Arborist #WC-3172 cell (415) 203-0990/ drtree@sbcglobal.net 7. Section 29.10.0965. Prohibitions: A pennit is required to prune, trim, cut off, or perform any work, on a single occasion or cumulatively, over a three- year period, affecting 25% or more of any Protected Tree (including below ground root system). a. Section 29.10.0965. Prohibitions: A permit is required to prune, trim, or cut any branch or root greater than four(4) inches in diameter of a Large Protected Tree. 9. Section 29.10.0965. Prohibitions: A permit is required to conduct severe pruning on any protected tree. Severe pruning is defined in section 29.10.0955 as •topping or removal of foliage or significant scaffold limbs or large diameter branches so as to cause permanent damage and/or disfigurement of a tree, and/or which does not meet specific pruning goals and objectives as set forth In the current version of the International Society of Arboriculture Best Management Practices-Tree Pruning and ANSI A300-Part 1 Tree, Shrub, and Other Woody Plant Management-Standard Practices, (Pruning).• 10. Exceptions: Severe Pruning Exception In Town Code section 29.10.1010(3) • ..... except for pollarding of fruitless mulberry (Marus alba) or other species approved by the Town Arborist.. .. ". Protected Tree Exceptions: a. Edible fruit or nut bearing trees less than 18 inches diameter (multistem total or single stem) b. Acacia melanoxylon (blackwood acacia) less than 24 inches (multistem total or single stem) c. Urlodendron tu/ipifera (tulip tree) less than 24 Inches (multistem total or single stem) d . Ailanthus altissima (tree of heaven) less than 24 inches (multistem total or single stem) e. Eucalyptus g/obulus (Tasmanian blue gum) less than 24 inches (multistem total or single stem) f. Eucalyptus csmaldulensls (River red gum) less than 24 Inches (multlstem total or single stem) g . Other eucalyptus species (E. spp .) not noted above, fess than 24 inches (multistem total or single stem) (REMOVAL O.K. ONLY AT HILLSIDE AREA LOCATIONS PER OFFICIAL TOWN MAP): VfNW.losqatosca.qov/documentcenter/view/176 h. All palm species (except Phoenix canariensis) less than 24 inches (multistem total or single stem) i. Ugustrum lucidum (glossy privet) less than 24 Inches (multistem total or single stem) Siie Adclrws: 20102 FosW Road, Los Gelol, CA Reglllind Mlmler, American Society Of COl1sull ng Alt>ol1&ls and Member Of the lrUrnatlonel Society of Alboriwture 0 Wallar LaYlson 2015 AB Rights RelefV8d 140f31 Version: 1Al/201 S ~h Walter Levison r CONSULTING ARBORIST M\ .=~:.::.·~""'-.... ASCA Registered Consulting Arborist #401/ ISA Tree Risk Aaamsmerrt Qualified/ ISA Certified Arborist #WC-3172 cell (415) 203-0990 I drtree@sbcglobal.net 7.0 Recommendations 1. Prolect Arborist <•pA"l: It Is suggested that a third party ASCA registered consulting arborist or ISA Certified Arborist with good experience with tree protection during construction be retained by the applicant to provide pre-project verification that tree protection and maintenance measures outlined in this section of the arborist report are adhered to . Periodic (e.g . monthly) inspections and summary reporting, if required as a project condition of approval, are suggested i!'l order to verify contractor compliance with tree protection throughout the site plan project. This person will be referred to as the project arborist c·pA•). The PA should monitor soil moisture within the root protection zones of trees being retained, using a Lincoln soil moisture probe/meter or equivalent. If required, Inspection reports· shall be sent to Mi. Erin Walters, Associate Planner, at ewalters@losgatosca.gov . Sample wordage for a condition of approval regarding monitoring of tree protection and tree condition: "The required protective fencing shall remain in place -until final landscaping and inspection of the project. Project arborist approval must be obtained and documented in a monthly site activity report sent to the Town. A mandatory Monthly Tree Activity Report shall be sent at least once monthly to the Town planner associated with this project (ewalters@losgatosca.gov )beginning with the initial tree protection verification approval letter-. 2. SD8Cial Prolect Arborlst Monitoring: The PA shall monitor pruning work on the south sides of oak #2 and bay laurel #3 during clearance pruning . to clear those areas for roadway/retaining wall work (if not adjusted southward as suggested by the CTA), and storm drain pipe installation (if to be installed p,er current proposed route within the canopy driplines of the trees). Where possible, all pru~ing shall be in accordance with ANSI A300 standards for tree care operations I pruning. The PA shall also monitor storm drain pipe installation which is currently proposed to occur within the canopy dripllnes of bay laurel #3 and oak #4. 3. pro!ect Team Actions or Clarifications Requested: a. Project team shall have the project surveyor accurately plot or verify tree trunk locations for trees #3, 4, 5, 6, 7, and #18 on the plan sheets for further review by Town planning division Staff. b. Site Plan Design Adjustments : i. Proposed storm drain (SO) pipe per sheet C·2 shall either be relocated to at least 15 or 20 feet from the. trunks of oaks #3 and #4 as a trenched system, or the pipe shall be Installed at its current proposed location as an over-grade trenchless system strapped to a standing steel bracket similar to the existing storm drain pipe outfall near oak #4. ii. In addition to the above suggested pipe adjustments in item #3b(i), the e:Xisting storm drain outfall area adjacent to oak #4 may need to be adjusted to slow storm water discharge by placing boulders or other materials over the existing concrete spillway area (subject to further discussion between Town Staff and applicant's project team members). 8119 AddnllS: 20102,.,.... Road, Loa Gel0$, CA ~ Marnti.. ~ Soclely d ConsullngMlarlatl and Member d lie~ ........... Soclely d M>oriaAn o W-Ul'ltson 2015 Al Rights~ 'i!Of31 Version: 1/8/2016 ~b Walter Levison r CONSULTING ARBORIST ASCA Registered Consulting Arborlst#401/ ISA Tree Risk Assessment Qualified/ ISAiCertifled Arborist#W~3172 M\ --~­~·--.. cell (415) 203-0990 I drtree@sbcglobal.net iii. Proposed landscape plantings (and any associated illligation pipe installation·s) should be removed from the proposed plan sheet L-1 such that there is a 15 to 20 linear foot minimum offset-betWeen the trunks of oaks #6, #7, and #8, and any landscape development downhill from the trees. Assume chain link root protection zone fence routes will be located approximately 15 linear feet minimum offset downhill from the trunks of the trees. iv. Proposed boulder rip rap slope armoring per sheet ~2,• If installation involves· any alteration of soil grades within 15 feet of trees #6, #7, or #8, should be eliminated. Other types of slope armoring or stabilization that will not require any alternations to soil grade (i .e. no scarification, excavation or grading) should be explored in order to avoid potential damages to the root zones of the above noted trees. v. Consider adjustment of the proposed . roadway and ~taining wall as shown on sheet C•2 such that there is a 15 to 20 foot offset between the trunk of oak #2 and the :retaining wall edge·(assume Jhat a root protection zone "wan· Will be required as a condition of approval to be erected at 1 O to 15 feet south of the trunk edge of oak #2). · 4. Tree Valuation CAoorajsall and Tree Security Bond Posting : The values of all trees on and adjacent to the site being retained were determined by the CIA µsing the trunk formula method as outlined in the glh edition of the Guide for Plant Appraisal .. Trunk cross· sectional area for each tree with mult!ple l'Tlainstems was calculated by totaling the sum of the cross sectional areas of the mainstems, and-entering that nu~ber into the -trunk formula . i Tree Tag Number (Retention Trees Appraised Value (Trunk Formula Method) OnM 1 $3320. : 2 $1 700. I i . 3 $2.080 . ,. ; 4 $5,200. : 5 $10,200. : 6 $7,000. 7 $4690. I 8 $3320. ! ; Total Value: $36;850. l ! The CTA suggests that, based on the '·aboveappraised dollat values ofthe. trees ·belng ·retained as determined· by the CTA, a standard tree security bond be posted by the applicant with.the City in the amount 6f $25,000, which is significantly less than the total appraised value of the eight trees noted above as being retained on and adjacent to the site. The Town code provides a mechanism that can require ·bond posting by a project applicant In the amount of $5,000 per tree being retained, or $25,000, whichever is less. In this case, there are eight trees being retained at or adjacent to the site which may be negatively affected by site work: 8 X $5,0QO = $40,000. · Site AddtM&: 20102 Foalllr Rmd,)..os Glltlll. CA ~ ~. Anwlcan SOc:il(y of Ccnultng Arborisls anCI Maml8r of the lntllrnllionlil Soc:lely of Arb~ C W llhlr LMWor12015 All Rigta RaeeMld 18 of31 Version: 1181201B ~h Walter Levison r CONSULTING ARBORIST Ji\ ,=:?.::..~~ ASCA Registered Consulting Arborist #401/ ISA Treo Risk Asaeesment Qualified/ ISA Certified Ari>orist #WC-3172 cell (415) 203-o990 I drtree@sbcglobal.net 5. Trunk Bytfer Tvoe Ill Protection: Install a trunk buffer around the lowennost 8 to 1 O feet of the trunks of the following on-site trees that are to be retained in very close proximity to construction (treas #1, 2, 3, 4). Wrap approximately 20 wraps of orange plastic snow fencing around the trunk between grade and 8 feet above grade to create a padding at least 1 to 2 inches thickness. Stand 2x4 wood boards upright, side by side, around the entire circumference of the trunk. Affix using duct tape (do not use wires or ropes). See spec image above right. 6. Chain Link Fencing Type I and/or rvoe II Protection: Erect five-foot tall chain link fence on seven-foot long, two-inch diameter iron tube posts pounded 24 inches into the ground (see sample image at right). PnMlemolitlon fence: Par the red dashed Hnes on the tree map In the CTA's arborlst report, around trees #1, 2, 3, 4, 5, 8, 7, 8. Approximate distances from fence to trunk: Tree #1: 15-feet south of trunk. Tree #2: 1 O to 15 feet south of trunk (If proposed roadway and retaining wall are adjusted southward as suggested by the CTA, then fence at 15 feet offset from trunk). Tree 13: 10 feet south of trunk. Tree M: 20 feet south of trunk. Tree ts: 35 to 40 feet east of trunk. Tree 16: 15 to 20 feet .northeast of trunlk. Tree '117: 15 to 20 feet northeast of trunk. Tree 18: 15 to 20 feet northeast of trunk. This fencing must be erected prior to any heavy machinery traffic or construction material arrival on site. The protective fencing must not be temporarily moved during construction . No materials, tools, excavated soil, liquids, substances, etc. are to be placed or dumped , even temporarily, Inside the root protection zone or •RPZ". No storage, staging. work. or othpr actjvities wj!I be allowed insjde the Rez <such as storm drain oloe straoolngl exceot with PA monitoring. Site AddreH: 20102 FGIS Road, Los Gatxia, CA Reglstar8d Melr'bar, American Society Of Consullng Arborists and Mlnt>er Of Iha lllBndonat Society or~ .. C Weller l..llvison 2015 All Rights RBBerved 17 Of31 Ver.Ion: 1M016 ~b Walter Levison r CONSULTING ARBORIST M\ ~~-:~-=..,.~..:;... ASCA Registered ConaulUng Arborist #4-01/ ISA Tree Risk Aslessment Qualified/ ISA Certified Amorist tM'C-3172 eel (415) 203-0990/ dltree@sbcglobal.net For the areas uphill from tms #1. 2. 3. and #4. silt fence shall be jnstalled per Pactsaae directions tucked under the soil on the uchill side of the fence. with a straw wattle pinned dgwn over the bottom of the silt fence edge as additional protection agajnst soil flows and soil slumcinq into the rogt Protection zone area <see Images at right>: Signage: The RPZ fencing shall have one sign affixed with UV-stabilized zip ties to the chain link at eye level for every 25-linear feet of fencing, minimum a·x11 · size each, plastic laminated, with wordage that includes the Town Code section that refers to tree fence protection requirements (wordage can be adjusted): TREE PROTECTION ZONE FENCE ZONA DE PROTECCION PARA ARBOLES -NO ENTRE SIN PERMISO- ·LLAME EL ARBOLIST A- REMOVAL OF THIS FENCE IS SUBJECT TO PENAL TY ACCORDING TO LOS GATOS TOWN CODE 29.10.1025 PROJECT ARBORIST: TELEFONO CELL: EMAIL: 7. lrrigatign Temporary puring Construction (jf applicable): Apply temporary irrigation to trees being retained, at a frequency and duration or total output to be specified by the project arborist (PA). Method of water delivery can be soaker hose, emitter line, garden hose trickle, water truck, tow-behind water tank with spray apparatus, etc. · SlleAddrwa: 20102~Rmd,LosGalDll,CA Riigla..d MlllW. Amanc8n Soc:iety of Conaullng M>orlsts ... ManH" of the lnlamallonlll Soc:iety of~ o WIH9r L.Mon 2015M ~ts ReseMld 18 of31 Verslan: 11812016 ~h Walter Levison r CONSULTING ARBORIST M\ ··-···-·~ ... ASCA Registered Consulting Arborist '4011 ISA Tree Risk Asaessment Qualified / ISA Cedified Atbortst #Wc-3172 eel (415) 203-o990 I drtree@sboglobal.net 8. Pruning I Clearance for Stonn Drain. Retaining Wall. Roadway, etc.: If the current proposed locations for retaining wall construction, roadway grading, and stonn drain llne strapping are not adjusted as is suggested by the CTA In his arborlst report, then oak #2 and bay laurel #3 shall be pruned prior to Installation of the root zone protection fence and prior to start of demoHtion or other site work . Pruning shall achieve at least 5 feet minimum horizontal and/or vertical clearance from the proposed new work.. All pruning shall be perfonned only by, or under direct full time supervision of an ISA Certified Arborist , and. shall confonn to the most current iteration of the American National Standard Institute pruning guidelines and accompanying ISA Best Management Practices I Pruning booklet • ANSI A300 (Part 1) tree, shrub, and other wood plant maintenance I standard practices (pruning). 2001. • Best Management Practices I Tree Pruning: companion publication to the ANSI A300 Part 1: tree, shrub, and other wood plant maintenance I standard practices (pruning). International Society Of Arboriculture. 2002. 9. Root Pruning : If woody roots measuring greater than 1-inch in diameter are encountered within 20-feet of any tree being retained during site work, contractors shall immediately alert the project arborist, and shall proceed to sever roots at right angles to the direction of root growth using sharp hand tools such as professional '-- grade loppers, hand shears, chain saw, A/C sawzall, or other tools only under his/her direct supervision. See spec images at right. Woody roots shall not be shattered or broken in any way as a result of site activities. Shattered or broken areas shall be hand dug back into clear healthy root tissue and re-severed at right angles to root growth direction under the direct supervision of the project arborist (PA). 10. Water Scray: Spray off foliage of all trees within 30 feet of construction activity using a very high power garden hose or a pressure washer system set on low pressure to wash both the upper and lower surfaces of foliage; This helps keep the gas portals (stomata) unclogged for better gas exchange which is crucial for nonnal tree function (see image at right In which a fire hose system was used to wash approximately 50 redwood tree specimens in Sunnyvale during a one year long demolition period). Spray should be applied approximately twice yearly, or when ambient airborne dust ·concentration is unusually high. . Site Address: 20102 FollBr Road, Loi GlllllS, CA ~ a.tent., AalllriCarl Society al Conldng Arbollela and a.tent. al the lnillnllllon8I Sodety al AlbolbAn OWlllttlt IAYison 2015AI R9its ReseMld 19-of31 V8111on: 1111QD16 ~II Walter Levison r CONSULTING ARBORIST ASCA Registered Consultlng Arborist #401/ ISA Tree Risk Assessment Quallfted /ISA Certified Arborlst #WC-3172 11. Landsc8oe Plan Notes: Specification for new tree installations : • Remove all girdling roots and circling rootS and scarify the rootball prior to installation . • Elevation of the top of rootball should be approximately 1 to 2 inches above surrounding grade at sites with heavy clay soil. • Ensure that the trunk flares (woody buttress root flares) are present and exposed at the base of trunk. Perfonn cursory root crown excavation to expose the flares if they are not visible. • Double 2-lnch diameter stakes . • Cinch-tie™ rubber tree ties, in double figure eight fonnation . • Cut stakes down to just above the Cinch tie elevation to avoid wind sway damage to tree . • Two (2) high volume output professional grade flood bubblers placed directly over the rootball . • Soil berm built over the edge of the rootball so that irrigation water is forced to percolate directly downward into the rootball via gravity. • Mulch covering the berm and surrounding soil. • Leave some or all temporary branches as-is at low elevations until tree is established 12 to 24 months post-planting . • Remove stakes and ties after tree is established, approximately 12 to 24 months post- ·planting . 8.0 Tree Protection and Maintenance Directions per Town Code M\ .-=::!··~~\;~ The following is excerpted directly from the 2015 iteration of the Town of Los Gatos tree ordinance sections which provide specific tree protection directions and limitations on root pruning and above-ground pruning : Sec. 29.10.1000. New property development. (a) A tree survey shall be conducted prior to submittal of any development application proposing the rem9val of or impact to one or more protected trees. The development application shall include a Tree Survey Plan and Tree Preservation Report based on this survey. The tree survey inventory numbers shall correspond to a numbered metal tag placed on each tree on site during the tree survey. The tree survey plan shall be prepared by a certified or consulting arborist, and shall include the following infonnation: (1) Location of all existing trees on the property as described in section 29.10.0995; (2) Identify all trees that could potentially be affected by the project (directly or indirectly-immediately or in long term), such as upslope grading or compaction outside of the dripline; (3) Notation of all trees classified as protected trees; Siie Adm.: 20102 Fost9r Riolld, Loa G-. CA Reglatered Member, An.ic.n Sodely of Consulf ng Arbollllls and Membet d.,. krt9malional Society of~ 0 Walllr LAl'll&on 2015 All Rlgllll ReMrwd 20of31 Veralan: 11812016 .- L '·~ ~\h Walter Levison ., CONSULTING ARBORIST · A~ ,=...~~-= .. ASCA ReglsteJad _C~~_ultlJlg Aft?orist #4o!f _ISAJr~_ ~Isl<. Aa"8ament Qi,lalified / ISA C!Jtlfiesl !i-rl>.Orist #WC-3172 cell (415) 203-0990 I drtree@sbcglobal.net (4) In addition, for trees four (4) inches in diameter or larger, the plan shall specify the precise location of the trunk and crown spread, and the species, size (diameter, height, cr6wn spread) and· condition of .the tree. (b) The tree survey plan shall be reviewed ·~)' the Town's <;onsulting arborlst who shall, after making a field visit to the property, indicate in writing or as shawn on apprpved plans, . which trees are .recommended for pre$ervation (based on a retention rating of high/moderate/low) using, as a minimum, the Standards of Review set forth in section 29.10 .. 0990. ·This plan shall be made part of the sfaff reporrto the Town reviewing body· upon its consideration of the appllcation·fornew property<teveropment; · (c) When development jmpacls are within tbe dr,ipline of or will . affect any protected tnte. the applicant shall provide a tree preservation report prepared by a certified or consulting arborist. The report; based on the findings of the tree survey plan and other relevant information, .shall be used to determine the health and structl:Jl"e of exiSting trees, the effects of the proposed · develos)ment and vegetation removal upon the trees, .recommendations for . specific precautions· necessary for .their preservation during all phases of development {demolition, grading, during construction, landscaping); and shall also indicate which trees are -proposed .for · removal. The : tree preservatJon report shall .. stipulate a required tree protection· ·mne (TPZ) for trees to be retained, -Including street trees, _protected trees -~nd trees whose canopies are hanging over the project site from adjacent properties. The TPZ shall be fenced as· specified in section 29.10.1005: (1) The final approved tree preservation report shall be included in the building permit s~t of development plans and printed on a sheet titled: Tree Preservation lnstructions (Sheet T-1). Sheet T-1 shall be ~ferenced on all relevant sheets (civil, demolition, utility, landscape, Irrigation} where tree impacts from improvements may be shown to occur; (2) · The Town reviewing body through Its sits and .oeslgn plan review shall endeavor to protect all trees recommended for preservation by the Towri's consulting .. arl>orist. The ·"Town reviewing body may determine if any of the trees recommended for pre~tion should be removed, if based upon the evidence submitted the reviewing body determines that due to special · site grading .or other unusual characteristics associated with the property, the preservation of the tree(s) would significantly preclude feasible. development of the property as described in Section 29.10.0990; (3) Approval of final site or landscape plans .by the· appropriate Town reviewin_g body shall comply with the following req~irements and conditions of approval: · · · · ~· The applicant ·shall, withrn ninety (90) days of final approval or :prior to issuance of a grading or bufiding permit, .whichever occurs first. secure an appraisal of the condition and value Of ·an trees included in the tree report affected • by the deVelopment tha~ are required to remain within the development ·usintr the Tree Value. Standard: methodology as set forth In this Chapter: The appraisal of each tree shall recagnize the locatiOn of'thia tree in the proposed develQpmenf. The 1:1ppraiS&I shall be performed in accordance with the current edition of the Guide for Plant:.A?Praisal published by the CounCil of Tree and Landscape Appraisers {CTLA) and the Species and Group Classification Guide published by the Western Chapter of the International · Society of Art>onculture. The appraisal shsll be performed at the applicant's expense, and the appraisal shall be subject to the Director's approval. · b. The site or land~pe plans shall indicate which trees are to be removed. However, the plans do not constitute approval to remove a tree untU a separate permit is granted. The property owner or applicant shall obtain a protected tree removal permit, as outlined in section 29.10.0980, for eachttee to be removed 'to satisfy the. purpose ofthis division. (d) Prior to acceptance of prtiposed development or $.Ubdlv.isiQn improvements, the developer shall submit to the Director a final tree preservation report prepared by a certified. or consulting arborist. This report shall consider .an trees that were to remain within the development. The report shall note the trees' h~lth . in relation te th8 ioitlally reported eondltion of the_ trees and shall nQte, ·any changes in the trees' numbers or .physical conditions. The applicant ·will then . be responsible for the loss of any ·tree not previously approVed for removal. For protected trees, which were removed, the ~l Of\jl Siie .'llld.-: 20102 ~ Rolld, l.ol GalDS, CA . Reglst.ed Member, Anak:en Scictety of Consullng Arborl•IS and Men«> et Of the lnllrnmjanal SOdety of Arbo~wtln o Waller l.9Ylson 2015 Al Rights Reaerved Verslan: 1/8!2016 a Walter Levison ~I(' CON'SULTING ARBORIST . · ASCARegistered COf1!ultlng Arborist f#4Q111SA Tree Risk Asses~l114iflt OuaH:fted / I~ c_ertifiecl Arborlst #WC-3172 , M\ -·-.......r--_________ .. eel (415) 203-0990 I drtree@sbcglobal.pet developer shall pay a penalty in -the amount of . the appraised value of such tree in addition . to replacement requirements contained in section 29.10.0985 of this Code. The appllcant shall remain responsible fQr the health and survival of all trees within the development for a period of five (5) years following acceptance of the public Improvements of the developmen~ or certificate of occupancy. ·(e) Prior to issuance of any demolition, grading or building p~rmit, the applicant or contractor shall submit to the Building Department a written statement and photographs· verifying that the required tree protection fence is Installed around street trees and protected trees In accordance with the tree preservation report. (f) If required by the Director and conditioned as part of a discretronary approval, a security gu~rantee shall be provided to the Town. Prior to the Issuance of any permit allowing construction to· begin, the applicant shall post cash, bond or other security satisfactory to the Director, in the penal sum of five -thousand dollars ($5,000.00) for eact:i tree required l o be preserved, or twenty..:five :thousand dollars ($25,000.00), whichever Is less. The cash, bond or other security shall be retained for a period of one (1) year following acceptance of the public improvements for the development and shall be forfeited in an amount equal to five thousand oollars ($5;000.QO) per tree as a civil penalty in 1he event that a tree or trees required to be preserved are removed, destroyed or severely damaged~ ' (g) An applicant with a proposed development which requiresi underground utilities shall avoid the installation of said utilities within the dripllne of existing trees whenever possible. In the event that this' is unavoidable, all trenching shall be done using directional boring, air-spade excavation or by hand, taking extreme caution to avoid damage to the root structure. Work within the dripllne of existing trees shall be supervised at all times by a certified or consultilg arborist ' · , I (h) It shall be a violation of this dMsion .for any property owner or agent of·the owner to fall Jto cornply with any development approval condition conceming preservation, ~tection , and maintenance· of a_ny pro¥ed tree. (Ord. No. 2114, §§I, II, 8-4-03) Sec. 29.1o.·1005. Protection · Of trees.during, construction. ,(a) Protective.tree fencing shall specify the following: (1) Size and materials; Six (6) foot high chain link · fencing, jmounted on two~inch . diametertgalva.nized Iron posts, shall be driven into the ground to a depth of at least two ·(~) feet at no more than 10-foot spacing. For paving area th~ Vtfilt not ·be· demolshed and when stipulated in a tree preservation plan , posts may be supported<by a concrete qase. , (2}-Are& type to be fenced. Type 1:-Enclosure with chain U~k fencSlQ of either the entire dnpline area or at ·the tree protection zone (TPZ), when specified by a certified or consulting arborist. Type II: Enclosure for" street trees located in a planter strip: chain link fence around the entire planter strip to the outer branches. Type Ill: Protection for a tree located in a small planter cutout only (such as downtown): orange plastic , I . fencing shall be wrapped ·around -the ·trunk from the grot,1nd to ·the" first · branch with 2-inch wooden boards bound securely on the outside. Caution shall be used:to avoid damaging any bark or brandies. (3) Duration of T~ I, II, Ill fencing. Fencing shall be i erected before demolition, g~ing or construction permits are issued and remain in place until the work is completed. Contractor shall first obiain· the approval of the project arborist on record prior to removing a tree protection fence; (4) Warning !Sign. Each tree. fence shal~ have ·prominently, d~played an 8.5X:11-inch "sign-stating: 'Waming-Tree Protection Zone-this fence shall not be removed and is subject to penalty according to Town Code 29.10.1025". · · of 3 1 Site AddlMs: 20102 Foll9r Qmd, Los Galoa, CA v.tak1n: 1/8fl016 R9gi$111red Mllrmar, Amarlcan Sodety of Conluning AltOl1119 •nd Member or tll9 lntemallon11 Society of ArbOl1aJtllre ci Wdlr UMson 201 5 All Rl"11s ReeeMld '> Walter Levison CONSULTING ARBORIST M\ .~~~,.. ASCA Registered Consulting Arborist #401/ ISA Tree Risk Assessment Qualified / ISA Certified Arborist #VVC-3172 oell (415) 203-0990 I drtree@sbcglobal.net (b) All persons , shall comply with the following precautions: (1) Prior to the commencement of construction, install the fence at the dripline,· or tree protection zone (TPZ) when specified In an approved arborist ·report, around any tree and/or vegetation to be retained which could be affected by the construction and prohibit any storage of construction materials or other materials, equipment cleaning , or parking of vehicles within the TPZ. The dripllne shall not be altered in any way so as to increase the encroachment of the construction. (2) Prohib it all construction activities within the TPZ, including but not limited to: excavation, grading, drainage and leveling within the dripline of the tree unless approved by the Director. (3) Prohibit disposal or depositing of oit, gasoline, chemicals or other harmful materials within the dripline of or in drainage channels, swales or areas that may lead to the dripline of a protected tree. (4) Prohibit the attachment of wires, signs or ropes to any protected tree. (5) Design utility services and irrigation lines to be located outside of the dripline When feasible . (6) Retain the services of a certified or consulting arborist who shall serve as the project arborist for periodie monitoring of the project site and the · heallh of those trees to be preserved. The prOJect arborist shall be present whenever activities occur which may pose a potential threat to the . health of the trees to be preserved and BhaU document all site visits. (7) The Director and project arborlst shall be notified of any damage that occurs to a protected tree during construction so that proper treatment may be administered. (Ord. No. 2114, §§ I, II, 8-4-03) Sec. 29.10.1010. Pruning and maintenance. All pruning shall be in accordance with the current version of the International Society of Arborlculture Best Management Practices-Tree Pruning and ANSl ·A300-Part 1 Tree, Shrub and OtherVlloody Plant Management-Standard Practices, (Pruning) and any special conditions as determined by the Director. For developments, which require a tree preservation report, a certified or consulting arborist shall be in reasonable charge of all activities involving protected trees, including pruning, cabling and any other work if specified. (1) Any public utility installing or maintaining any overhead wires or underground pipes or conduits in the vicinity of a protected tree shall obtain permission from the Director before pertonning any work, including pruning, which may cause injury to a protected tr9e. (e.g. cable lV/fiber optic trenching, gas, water, sewer trench, etc.). (2) Pruning for clearance of utility lines and energized conductors shall be performed in compliance with the current version of the American National Standards Institute (ANSI) A300 (Part 1 )-Pruning, Section 5.9 Utility Pruning. Using spikes or gaffs when pruning, except where no other alternative is available, is prohibited. (3) No person shall prune, trim , cut off, or perform any work, on a single occasion or cumulatively, over a three-year period, affecting twenty-five percent .or more of the crown of any protected tree without first obtaining a permit pursuant to this division except for pollarding of fruitless mulberrY trees (Marus alba) or other species approved by the Town Arborist. Applications for a pruning permit shall include photographs indicating where pruning Is proposed. Sita .~ 20102 ,,_.,. Roed, l..Cll Ga10S. CA Registered Member, AmaflQm Society ol Conaulll~ MKxlala and Member of the lntJamallonel Society llf ArbaolCIAlura c Wsltar lelllson 2015 Al Rlghla R--..ct 230f"31 Version: 1/8/2016 ~ha Walter Levison .. , CONSULTING ARBORIST A~ M~ .:~-=-;".~ ASCA Registered Consulting Art>orlstj#401/ I~ Tree ~lsk Assessment Qualified/ ISA! Certified Artlorist #YVC-3172 cell ( 415) 203-0990 I drtree@sbcglobal.net . I ' (4) No person shall remove any Heritage tree or large protected tree branch or root through pn!Jning or other method greater than four (4) inches in diameter {12.s· in ci"cumference) without first obtaining a1pennit pursuant to this division. ' {Ord. No. 21·14,.§§ I, II, 8-4..;03) 9.0 Tree Replacement Standards -Los Gatos Town Code {Excerpted from Town Code 29.10.0985 and 29~ 10.0987) (1) Two {2) or more replacement trees; of a species and size designated by the Director, shall be planted on the subject private property; Table 3-1 The Tree Canopy-Replacement Standard shall be used as a basis for this requirement; The person requesting the pennit shall pay the cost of purchasing and planting the replacementtrees. (2) If a tree or trees cannot be reasonably planted on the i subject property, an in-lieu pa}'iient in an amount set forth by the Town Council by resolution shall be paid to the Town Tree Replacement Fund to: . a . Add or ~ce trees on public property in the vicinity of the subject property; or b. Add or replace trees or landscaping on other Town p~operty; or c. Support the Town 's urban forestry management program. (Ord. No. 2114, §§ I, 11, 8-4~03) Table 3-1 -Tree Canopy-Replacement Standard ----S1ngte.f'am11y Celvn01J.lf 6iZe of RembVed T,_ 1 ReplecemenL Requf rement2A Resldiritlal ~s . I 1 O feet or less TJWO 24 inch box trees Two 15 gallon trees I More than 1 O feet to 25 feet 11.hree 24 inch box .trees Three ' 15 gallon trees ·t=our 24 inch box trees; or ! More than 25 feet to 40 feet two 36 inch box trees Four 15 gallon trees More than 40 feet to 55 feet ~ix 24 inch box trees: Not Available or Three 36 inch box ' Greater than 55 feet 'Jren 24 inch box trees; or F,ive 36 inch box trees Not Available Notes 24 31 Site.Add-• 20102Foallllr Road, Los GlltDI, CA Ver&lcin: 1/812016 Raglilterecl Manmw, American Society of Conautlng Alborllll 111d Meniler of th• lntametlonal Society of MlOl1~ture ow,,_ LIMson 201s Al ~ta ~ ·~__, ~ "-' ' Walter Levison CONSULTING AABORIST ... ~ ~~ ~~ .... --~ ASCA Registered Consulting Arborist #401/ ISA Tree Risk Assessment Qualified I ISA Certified Arbortst #WC-3172 cerr {415) 203-0990 I drtree@sbcglobal.net 1To measure an asymmetrical canopy of a tree, the widest measurement shall be used to determine canopy size. 2otten, It is ·not possible to replace a single large, older tree with an equivalent tree(s). In this case, the tree may be replaced with a combination of both the Tree Canopy Replacement Standard and in-lieu payment In an amount set forth by Town Council resolution paid to the Town Tree Replacement Fund. 3single Family Residential Replacement Option is available for developed single family residential lots under 10,000 square feet that are not subject to the Town's Hillside Development Standards and . Guidelines . All 15-gallon trees must be planted on-site. Any in-lieu fees for single family residential shall be based on 24" box tree .rates ~s adopted by Town Council. 4Replacement Trees shall be approved b)' the Town Arborist and shall be of a. species suited to the available planting location, proximity to structures, overhead clearances; soil typ.e, compatlbllity with surrounding cenopy and other relevant factors. ·Replacement with natiw species shall be strongly encouraged. Replacement requirements in the Hillsides shall comply with the Hillside Development Standards and Guidelines Appendix A and Section 29.10.0987 Special Provisions-Hillsides. Sec. 29.10.0987; Special ·prc>Vlsions-Hillsides The Tovvn of Los Gatos .recognizes Its hillsides as an important natural resource and sensitive · habitat which Is also a key component of the ToWn's identity, .character and .charm. In order to maintain and encourage restoration of the hillside environment to Its natural state, the Town has established the following special provisions for tree removal and replacement in the hillsides: (1) All protected trees located 30 or more feet from the primary residence that are removed shall be replaced with native trees listed in Appendix A Recommended Native Trees for Hillside Areas of the Town of Los Gatos Hillside Deve/aprnent Standards and Guidelines (HDS&G). (2) All protected trees toc&ted within 30 feet of the primary residence that are removed shall be replaced as follows: (a) If the . removed tree is a native .tree. listed In Appendix A of the HDS&G, it shall only be replaced with a native tree listed in Appendix A of theHDS&G. .. (b) . If the removed tree is not listed in Appendix A. it may be replaced with a tree listed in Appendix A, or replaced with another species of tree as approved by the Director. (c) Replacement trees listed in AppendixA .maybe planted anywhere on the property. . . (d) Replacement trees not listed In AppeiidiX Amay·only be planted within 30 feet of the primarY residence. (3) Replacement requirements shall comply with the requirements in Table 3-1 Tree Canopy Replacement Standard of this Code. (4) Property owners should be encouraged to retain dead or declining trees where they do not. pose a satety or fire hazard, in order to foster wildlife habitat and the natural renewal of the hillside environment. Sile Adclr9a: 20102:.,_. Reed, Los GalOll, CA Ragl9"'r9d Memb ... Amerie1n Society or Consull~ MxlrllllB and Member or th• l~lmmllllon•I Society of ArtoriCIAn 0 Waller l..8vtaon 2015 Al ~ta RMervad 25or31 Verslm: 1llll2016 - -~b Walter Levison r CONSULTING ARBORIST i}\ ..=::::.-.:=.~~ ASCA Registered ConsUtlng Alborist#401/ ISA Tree Risk Assessment Qualified/ ISAJCertified Arborist#WC.31n eel (415) 203-0990 I drtree@sbcgtobal.net 10.0 Author's Qualifications • Continued education through The American Society of Consulting Arborists , The International · Soctety of Arboriculture (Western Chapter), and various governmental and non-iJOvernmental entities. • Contract Town Arborist, Town of Los Gatos, California Community Development Department I Planning Division 2015-present • Tree Risk Assessment Qualified (ISA TRAQ Course Gradua •• Palo Alto; California) • Millbrae Community Preservation Commission (Tree Board) 2001-2006 • ASCA Registered Consulting Arborist #401 I • ASCA Arboriculture Consulting Academy graduate, class of ~000 • Associate Consulting Arborist Barrie D. Coate and Associates 4/99-8/99 • Contract City Arborist, City of Belmont, California Planning and Community Development Department 5/99-present • ISA Certified Ai'borist #WC-3172 • Peace Corps Soil and Water Conservation Extension Agent Chiangmai Province, Thailand 1991 ~1993 • B.A. Environmental Studies/Soil and Water Resources UC Santa Cruz, Santa Cruz, California 1990 (My full curriculum vitae.is available upon request) S,ite·Add,_: 20102 F°"8r Road, loll GallOll; CA ~-29of31 ~ Men'lb«, An*'«:an Sociely of Consulfng Arboriats and Mimi« of'"' ln'8mlllional Society of~ c W•ll9r I.Mon 2015 All Righl:I R8serwd Versi()n: 11812018 .. ' '-'-- ' Walter Levison CONSULTING ARBORISl ~ ~-=:.:r. ASCA Registered Consulting Arbor1st#401/ ISA Tree Risk Assesement Qualified/ ISA Certified Arborist tN/~172 cell (415) ::!03-0990 I drtree@sbcglobal.net 11.0 Assumptions and· Limiting Conditions Any legal de9Criptlon provided tD the c:cnsultant/appralser Is .. umed to be correct. Any tllles and CM1nershlp ID any pn>perty are a19Ullled to be good and mar"8table. No reeponslbllly ii assumed for matters legal In character. Any and al property is appralied and evaluated as through he and clean, under responsible ownership and competent management. It is assumed that any property is not in vlolation of any applicable codes, ordinance, statutes, or other govemment regulations. Care has been taken to obtain all Information from reliable sources . All da~ has been verified i.nsofar ~ P.Q8Sille: however, the consullantfappraiser can neMher guarantee nor be nssponsible for the accuracy of lnfonnatlon.provided by others. The consultanUappraiser shall not be req._.lred to give teSll!110i1)' ot to attend C.O!J!'l ·bV reason of this report Unless subsequent cOnln!i:tUal arrangemenll flltl made, Including ~nt of an addltlonal fee for &Uctf servlce!I as~ m 1ho fee~ •. • Conlract ·of -~ Unless required by I.aw oth~se. the ••sslen of thli report Or a .CQPY the~of does not .rmply right of publlcatlon or u5e Jor any ~~r purpose by any other than the person to whom it Is addressed, wi1h~1he prtor expressed wottso or verbal consent qfthe consultant(a11Pf81$er. · · · Unless required by law otherwise, neither all nor any part oflhe ~nts of this report, nor copy thereof, shaU be conv.eyect by anyc)ne, including the chant, to the public through advertising, public relations, news, sales .• or other media, willJOut the prior elCpRl8Sed conctus1on$, Id.entity Of the consultant/appraiser, or any reh!~nce to ~my profess1onaJ society or institute or to any initiated ·designation conferred upon the oonsultantlappra1ser as stated m. hl~I quali_ficatlQns. · Thi& report and any values expreaaed henlln represent the op111on of-the consulfantfllpprai~r. •nd the consultanl'ala~praiaer's fee l• fi1 no wey contingent upon the reporting of a spac:illed value, a stipulated reeult, the occurrenQ& of a s1o1beequent.eveit, nor upon any finding to be repOrtacl. · · ' . . · · . . . .. Sketches, drawings, and phOtographs in this report, being iJ:ttanded for visual aids, 819 not necessarily to scale and shoold not be construed as engineeiing or archbctural reports or tuveys unless expressed' Otherwise T-he reproduction of any lnfonnallori.generated by ·engmee"° architects, or other consultants-on any sk~ drawings', or photographs iS for the express purpose of coordination and ease ohefe"91lc:e only lnclusron of.said 1nfonttat;on on any drawings or ~er documents does notcomn:ttute a representation by Walter Levison to the sufficiency or .aca.1racy of said infonnation. · · Unless expressed othefWise: a. lnfonna11on contained In thlS report CbVer8 only th088 •• that were examined and reflects the condltlo,. of those Items at the time of lnspedlon; and b. the Inspection is Hmlted to visual e.xam1natioo of 8cceulble-Items Without dlllMICtlon, excavation, probing , or coring. There Is no warranty or guarantee, expressed or impled, that prcblems ordeftciem;:les of the plar'lts or property !n q1,1atlon ma; not arise In .the future . · · Loss or alteration of any part of this report Invalidates the entire report. 1 Arborlst Dlsc/osure Statement: ·-Arborists are tree speclalists who use their education, know~. training, and experfence to examine trees, recommend measures to enhance the beauty and health of trees, and attempt to reduce the rllk of living near ne.. Cllenlll may chooae to accept or disregard 1he recommendation• of1he art>orlet, or to aeek addiUonal advice. Arborlsts cannot dM9cl eVlfY condition tt1'l could poaslbly l8ad to the · structural failure of a tree. Tree are llving organism• that fail In ways we ·do not fully understand. Conditions ate often hidden wtthl.n trees .and below ground . Arbortst cannot guarantee that a tree wlll be healthy or safe under all circumstances, or for a specified period of time. Li'<ewise, remedial treatments, like any medicine, cannot be guaranteed. Treatment, pnnng, and removal of trees may involve considerations beyond the scope of the art>orist's services such as property boundaries, property OIM18f'Ship, site lines, disputes between neighbors, and ottter Issues. Arborlsts cannot take such considerations into account unless complete and a(;CUl'8fa information is disclosed to the arbor1st An arborlst should then be expected to reasonably rely upon 1he completeness and accuracy of the infonnation provided. Trees can be managed, but they caMOt be.controlled.. To Uve a.rtrees Is to accept .some~ ,of risk. The only way to ellmlnate ell risk associated with trees is to ellmlnate the trees. Si'-Addrau: 20102 FGlllw Roed. Los Gatoa. CA ~ Merrber, Anatcan Society of Consultng Albollstl 8lld ............ of the lnllrMlan.i Society of ArbabAft ~ WIMM 1.8v11U1 2015 M Rlghla ReseMld 27 of31 ve..ion: 1i8/2018 ~~ Walter Levison r CONSULTING ARBORIST ASCA Registered Consu11in9 Arborlst #401/ ISA Tree Risk Assessment Qualified / ISA Certified Arborist #WC-3172 12.0 Certification M\. -~,. ....... ~·­. -..... _....__ ... cell (415) 203-0990 I drtree@sbcglobal.net I hereby certify that all the statements of fact in this report are true, complete, and correct to the best of my knowledge and belief, and are made in good fa ith. Signatwe of Consultant ~· ._ - 13.0 Digital Images WLCA archived images of survey trees on 1/8/2016. Tree# 1 Sile Addraa: 20102 Fotler Raad, Los Gatas, CA R1IQl.w.ct ....-. Amer1cm1 SOCiely or Consulting Atbortsts and Mlmler or"• 111Wm8licnal Sodely or Albarlculu. OWaller Levison 2015 All Rlgl!lll Relerwcf Tree# lmaae 2 2hf3f Version: 1/!lf20111 ,\\h Walter Levison V(' CONSULTING ARBORIST ASCA Registered Consulting Arborist #401/ ISA Tree Risk Assessment Quallfled /ISA Certified Arbortst #Wc.3172 Tree# lmaae 3 Bay '#3 is In background center of image. Site Mdress: 20102 ,,_. ROad, Los Gatoe, CA Regi*1Jcl ,...,_, ~ Society ol Conlultru lll1'ollltS and M9mber of the lnlilmlllanal SOd«y ol AlboriaAae o Waltar Levison 2015 /II Rights~ Tree# 4 29iif3'f M\ ·==-~~ ... ~ cell ( 415) 203-0990 I drtree@sbcglobal.net Existing outfall shown at left side of image as an over-grade strapped pipe discharges storm water onto a concrete spillway that seems to actually Increase water velocity as it passes by the trunk of oak ##4. Venilon: 1/8/2016 .\\la Walter Levison Y'I(' CONSULTING ARBORIST ASCA Registered Consulting Arborist #401/ ISA Tree Risk Assessment Qualified/ ISA Certified Arborist #Wc-3172 Tree# lmaae 4 Upper elevafion portion of canopy. 5 1 Site~ 20102 Foltll" lad. Los Ga1De. CA Reglster8CI Meriler, Amerie1n Society of Consulting Atllollm •nd Merriler al the International Society d Arbartc:Uture c Walter LavllOfl 2015 All Rlgllts Reservecl Tree# 5 6 M\ '~~~--u:,::,~: .. cell (415} 203-09~/ drtree@sbcglobal.net Bay #5 shown at left side of image. There is some existing rip rap material downhill from this tree, but it Is much farther from trunk than the location proposed for new rip on the applicant's sheet C-2. v.ralon: 1/&'2016 / .. ~h Walter Levison r CONSULTING ARBORIST ASCA Registered Consulting Arborist #401/ ISA Tree Risk Assessment Qualified/ ISA Certllled Arborist #WC-3172 Tree# 7 Note that these native blue oaks (trees #6, 7, 8) are relatively very sensitive to construction pressures such as cuts, fills, changes in hvdroloav, e~. when comoared l-o other soecies of trees. ~ Siie Address: 20102 Foll8t Road, Loe Gitos, CA Reglstared Membar, Almrtcan Society of ConSUllr4I Alborists and Maniler of ll• lnlllmdoMl Society of AttorlaAn 0 Wlllilr l.eYl!lOR 2015 M Rl"11a Reserwd T~e# 8 M\ ."!'::.~~~..:..: .. eel (415) 203-0990 I drtree@sbqJlobal.net veraon: 111V101 e MATERIAL SAMPLE BOARD COKER RESIDENCE 20102 FOSTER ROAD LOS GATOS, CA 95030 Recerveo ~-llf-JZZ. JUL 2 4 2017 TOINN OF LOS GATOS PLANNING DIVISION l 'CAP & PAN' DLE ROOFING REDLAND CLAmLE-lWO-PIECE MISSION 2000 SERIES-OLD SEDONA BLEND -AVERAGE 15.5 LRV CHIMNEY CAP, GUlTERS & DOWNSpGUJS ARCHITECTURAL COPPER SOFFIT MOLDING, OOERIOR TRIM ELEMENTS / COLUMNS COLOR INTEGRAL STUCCO PlASTCR ANISH W/ 1MILLBROOK STONE' CUSTOM CAST STONE EXTERIOR WALL SIDING BUECHEL FIELDSTONE -OVERGROUT FINISH EXTERIOR WALL SIDING COLOR INTEGRAL STUCCO SIDING HARD TROWELED SMOOTH FINlSH TO MATCH KEL.i. Y MOORE KMS716-3 'RODEO ROUNDUP1-LRV 30 EXTERIOR WINDOWS/DOORS Q.AD WOOD 1DARK BRONZE' M E T R 0 ANODIZED ALUMINUM D E S I G N "l:'VVT»rr 1 } GROU P ~& 1475 S BASCOM AVE SUITE 208 •CAMPBELL, CA 95008 • (408) 871-1071 PH • (408) 871-1072 FAX 17-24· UI MATERIAL SAMPLE BOARD COKER RESIDENCE 20102 FOSTER ROAD LOS GATOS, CA 95030 EXTERIOR WROUGHT IR()N DOORS. RAIUNGS. GATE WROUGHT IRON -1BRONZE 1 COLOR SJONEPADO 'FRONTIER TAN' FLAGSTONE METRO DESIGN GROUP GARAGE DOORS DARK STAINED WOOD 'CARRIAGE' STYLE DOORS DRJVE1NAY,\NALK\NAYS PERVIOUS PAVERS-'XERIBRIX' BY 'XERIPAVE SUPER PERVIOUS PAVERS' -HERRINGBONE PATTERN, DUPONT COLOR 1475 S BASCOM AVE SUITE 208 •CAMPBEL!., CA 95008 • (.q(J8) 871-1071 PH• (408) 871-1072 FAX ~-24-1~ Neighborhood Notification Form Date : µ(A/l ~I ,. 20 11 PROJECT ADDRESS: 20102 Foster Road Los Gatos, CA 95030 Applicant's Name : Scott Coker RECEIVED 6-11.f-17-Z AP~ O ~ 2017 TQ\ll_'N OF LOS GATOS PLA1·J:~ING DIVISION c My Signature beJow certifies that I reviewed the project plans; I understand the scope of work; and I do NOT have any concerns or issues which need to be addressed by the applicant; I c.an support the project as proposed. Neighbor's Name:,_.__~' ---'-( ,,_.l C-___ 1 ff'---l'r'----""-fL_ ....... ft_5_1 Al----=-6,___ Neighbor's Address: U>) e ~ "fos/:av Ro\. Le .~ 6~ 1 C#. Signature: __ ~i_1t __ 1 _Q_~ __ \_. __ ·......_ __ _ EXHIBIT l 3 Neighborhood Notificoition Fo_rm Date:. __ 4_-_/_D_-_1_7'-------- PROJECT ADDRESS: 20102 Foster Road Los Gatos, CA 95030 Applicant's Name: 5cott Coker RECEIVED s-1L..\-t -i. z.... APR 10 2017 TOWN OF LOS GATOS PLANNING DIVISION o My Signature below certifies that I reviewed the project plans; l understand the scope of work_; and I do NOT have any concerns or issues which need to be addressed by the applicant; I can support the project as proposed. Neighbor's Name: di?~ <ffl./?n0<1 Neighbor's Address: ~Q \ 0 e .;pog 1/d!-12.() Lpe, CP 4T?J& I Cit I q6l>Bo ·----·-------------------------------------- PUBLIC COMMENT Public comments received by 11:00 a.m., August, 18, 2017 NONE This Page Intentionally Left Blank METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-0.0 Coker Residence PC2 6-30-17.pln7/5/20174:02 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 PROJECT SITE GENERAL NOTES VICINITY MAPPROJECT INFORMATION ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE FOLLOWING CODES, AS WELL AS ALL APPLICABLE STATE CODES & LOCAL CITY ORDINANCES, 2016 CALIFORNIA BUILDING CODE (C.B.C.) 2016 CALIFORNIA RESIDENTIAL CODE (C.R.C.) 2016 CALIFORNIA ELECTRICAL CODE (C.E.C.) 2016 CALIFORNIA PLUMBING CODE (C.P.C.) 2016 CALIFORNIA MECHANICAL CODE (C.M.C.) 2016 CALIFORNIA FIRE CODE (C.F.C.) 2016 CALIFORNIA ENERGY CODE (C.E.C.) 2016 CALIFORNIA GREEN CODE (C.G.C.) NOTHING ON THE DRAWINGS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES & REGULATIONS. GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL EXAMINE THOROUGHLY THE SITE AND SATISFY THEMSELVES AS TO THE CONDITIONS TO WHICH THE WORK IS TO BE PERFORMED. THE CONTRACTOR SHALL VERIFY AT THE SITE ALL MEASUREMENTS AFFECTING HIS WORK, AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF THE SAME. NO EXTRA COST TO THE OWNER WILL BE ALLOWED RESULTING FROM HIS NEGLIGENCE TO EXAMINE OR FAILURE TO DISCOVER CONDITIONS AFFECTING HIS WORK. CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN ON THE DRAWINGS BY TAKING FIELD MEASUREMENTS; FOR PROPER FIT AND ATTACHMENT OF ALL PARTS IS REQUIRED. SHOULD THERE BE ANY DISCREPANCIES, IMMEDIATELY REPORT TO THE ARCHITECT IN WRITING PRIOR TO COMMENCEMENT OF ANY RELATED WORK. IN THE EVENT OF THE CONTRACTOR'S FAILURE TO DO SO, THE CONTRACTOR SHALL BE FULLY AND SOLELY RESPONSIBLE FOR THE CORRECTION OR ADJUSTMENT OF ANY SUCH RELATED WORK OR ERRORS. DO NOT SCALE THESE DRAWINGS. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DRAWINGS. MINOR DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS ARE TO BE EXPECTED. CONDITIONS REQUIRING CLARIFICATION SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. CONTRACTOR AND ALL SUBCONTRACTORS SHALL INSTALL OR APPLY, AND PROTECT ALL PRODUCTS, MATERIALS, PROCESSES, METHODS, COATINGS, EQUIPMENT, APPLIANCES, HARDWARE, SOFTWARE, ETC. IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS, DETAILS & INSTRUCTIONS, TYPICAL. ALL MANUALS OR INSTRUCTIONS PROVIDED BY THESE MANUFACTURER'S FOR PROPER OPERATION AND MAINTENANCE OF THE ABOVE ARE TO BE DELIVERED TO THE OWNER AT THE COMPLETION AND FINAL INSPECTION OF THE PROJECT. CONTRACTOR SHALL VERIFY THE QUANTITY, ROUGH OPENINGS AND TYPES OF DOORS AND WINDOW AND DOOR SCHEDULES IN RELATION TO FRAMING PER FIELD PRIOR TO ORDERING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. ALL ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AND AEROSOL PAINT CONTAINERS MUST REMAIN ON THE SITE FOR FIELD VERIFICATION BY THE BUILDING INSPECTOR. PER CGBSC SEC. 4.504.2.4 PRIOR TO FINAL INSPECTION, A LETTER SIGNED BY THE GENERAL CONTRACTOR OR THE OWNER/BUILDER (FOR ANY OWNER/BUILDER) PROJECTS MUST BE PROVIDED TO THE CITY OF SAN JOSE BUILDING OFFICIAL CERTIFYING THAT ALL ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AEROSOL PAINTS, AEROSOL COATINGS, CARPET SYSTEMS (INCLUDING CARPETING, CUSHION AND ADHESIVE), RESILIENT FLOORING SYSTEMS, AND COMPOSITE WOOD PRODUCTS INSTALLED ON THIS PROJECT ARE WITHIN THE EMISSION LIMITS SPECIFIED IN CGBSC SECTION 4.504. 1. CODES AND REGULATIONS 2. SITE VERIFICATION 3. MEASUREMENTS 4. DIMENSIONS 5. DISCREPANCIES 6. MANUFACTURER'S SPECIFICATIONS 7. WINDOWS AND DOORS 8. CALGREEN STANDARDS DZ AS-NOTED COVER SHEET AREA TABULATIONS GENERAL NOTES PROJECT INFORMATION AREA TABULATIONS PROJECT DESCRIPTION VICINITY MAP SHEET INDEX CONSULTANT DIRECTORY CONSULTANT DIRECTORY PROJECT DESCRIPTION ARCHITECT METRO DESIGN GROUP CONTACT: TOM SLOAN A.I.A. 1475 S. BASCOM AVE. # 208 CAMPBELL, CALIFORNIA 95008 (408) 871-1071 PHONE (408) 871-1072 FAX TOPO SURVEY & BOUNDARIES KIER & WRIGHT CIVIL ENGINEERS & SURVEYORS, INC. 3350 SCOTT BOULEVARD, BUILDING 22 SANTA CLARA, CA 95054 (408) 727-6665 PHONE (408) 727-5641 FAX PROPERTY OWNERS PHONE MAILING ADDRESS PROJECT ADDRESS SITE AREA A.P.N. ZONING LAND USE GENERAL PLAN DESIGNATION LOCATED WITHIN DESIGNATED WILDLAND URBAN INTERFACE FIRE AREA SETBACK REQUIREMENTS MAX HEIGHT ALLOWABLE / PROPOSED CONSTRUCTION TYPE OCCUPANCY FIRE SPRINKLERS 5% MIN, AWAY FROM THE STRUCTURESLOPE AT LANDSCAPE AREAS: SLOPE AT PAVED AREAS:2% MIN, AWAY FROM THE STRUCTURE 1% MIN, AWAY FROM THE STRUCTURESLOPE AT LANDING AREAS: 1. SITE AREA - PER HILLSIDE DEVELOPMENT STANDARDS AND GUIDELINES GROSS: 166,815 SQ. FT. (3.83 AC) NET AFTER REDUCTION: 66,726 SQ. FT. (1.53 AC) AVERAGE SLOPE OF SITE: 45.40 % AVERAGE SLOPE AT BUILDING PAD (LRDA): 2.20 % 2. FLOOR AREA CELLAR FLOOR (SQ. FT.) EXEMPT FIRST FLOOR (SQ. FT.) GARAGE (400 SQ. FT. EXEMPT) ACCESSORY BUILDING (SQ, FT.) TOTAL AREA (SQ. FT.) * CELLAR AND 400 SQ. FT. GARAGE ARE EXEMPT TOTAL ALLOWABLE FLOOR AREA: 6000 SQ. FT. PER HDSC TABLE 2/PAGE 28. 3. BUILDING COVERAGE MAXIMUM ALLOWABLE COVERAGE: NO MAXIMUM PROPOSED COVERAGE: 8,071 SQ. FT. 12.09 % BUILDING(S) 5,997 SQ.FT. GARAGE (EXEMPT AREA) 400 SQ.FT. PORCHES 1,674 SQ.FT. TOTAL 8,071 SQ.FT. 5. PARKING SPACE 3 COVERED AT GARAGE SCOTT COKER (408) 393-7574 1942 COASTLAND AVENUE SAN JOSE, CA 95125 20102 FOSTER ROAD LOS GATOS, CA 95030 GROSS: 166,815 SQ. FT. (3.83 AC) NET AFTER REDUCTION: 66,726 SQ. FT. (1.53 AC) 537-33-009 HR -21/2:PD EXISTING: UNDEVELOPED PROPOSED: SINGLE FAMILY RESIDENCE LOW DENSITY RESIDENTIAL YES REQUIRED FRONT: 30'-0" SIDE: 20'-0" REAR: 25'-0" PROPOSED FRONT: 30'-0" LEFT SIDE: 22'-6" RIGHT SIDE: 199'-1" REAR: 30'-4" ALLOWED PROPOSED 18'-0" 18'-0" V-B R-3/U REQUIRED (NFPA-13D) GEOTECHNICAL ENGINEERING A- 2.1 WATER USE CALCULATIONS SHEET INDEX SHEET INDEX, PROJECT DESCRIPTION, VICINITY MAP, CONSULTANTS, GENERAL NOTES AND TABULATIONS L- 0 A- 0.0 EXTERIOR ELEVATIONS A- 2.0 MAIN FLOOR PLAN A- 5.0 C- 3.0 SITE PLANA- 1.0 A- 4.0 ROOF PLAN EROSION CONTROL PLAN C- 2.0 TOPOGRAPHIC AND BOUNDARY SURVEY C- 1.0 PRELIMINARY GRADING & DRAINAGE PLAN A- 3.0 CELLAR FLOOR PLAN CROSS SECTIONS SITE DIAGRAMS, SITE DETAILS EXTERIOR ELEVATIONSA- 4.1CONSULTING ARBORIST EXTERIOR ELEVATIONSA- 4.2WALTER LEVISON CONTRACT TOWN ARBORIST (415) 203-0990 PHONE drtree@sbcglobal.net APPLIED WATER RESOURCES, CORP. CONTACT: KENDALL W. PRICE CEG, REA 1046 WEST TAYLOR STREET, SUITE 105 SAN JOSE, CA 95126 (408) 496 0801 PHONE A- 1.1 PROPOSED NEW ONE STORY RESIDENCE WITH ATTACHED THREE CAR GARAGE, ACCESSORY BUILDING AND SWIMMING POOL IN COMPLIANCE WITH TOWN OF LOS GATOS HILLSIDE DEVELOPMENT STANDARDS AND GUIDELINES. TOWN NOTES, PROJECT DATA & LEGEND C- 4.0 C- 5.0 EROSION CONTROL DETAILS C- 6.0 CONSTRUCTION DETAILSC- 7.1 FIRE PROTECTION WATER AN AUTOMATIC NFPA 13 FIRE SPRINKLER SYSTEM APPROVED BY THE SANTA CLARA COUNTY FIRE DEPARTMENT SHALL BE INCLUDED IN ALL PORTIONS OF THE BUILDING. THREE SETS OF PLANS PREPARED BY A SPRINKLER CONTRACTOR SHALL BE SUBMITTED TO THE SANTA CLARA COUNTY FIRE DEPARTMENT (14700 WINCHESTER BLVD., LOS GATOS, CA 95032) FOR REVIEW AND APPROVAL. THE SPRINKLERS SHALL BE INSPECTED AND APPROVED BY THE FIRE DEPARTMENT PRIOR TO FINAL INSPECTION AND OCCUPANCY OF THE BUILDING. A. AN APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM, HYDRAULICALLY DESIGNED IN ACCORDANCE WITH NFPA STANDARD 13 -2013 EDITION AND LOCAL ORDINANCES SHALL BE INSTALLED THROUGHOUT THE ENTIRE STRUCTURE. THE FIRE SPRINKLER SYSTEM SUPPLY VALVING, FIRE DEPARTMENT CONNECTION (FDC), ETC., SHALL BE INSTALLED AS REQUIRED TO COMPLY WITH NFPA 13 REQUIREMENTS. B. FAST RESPONSE FIRE SPRINKLER HEADS SHALL BE INSTALLED THROUGHOUT THE GARAGE AND ALL CONTIGUOUS AREAS WITHIN THE STRUCTURE. C. A STATE OF CALIFORNIA LICENSED FIRE PROTECTION CONTRACTOR SHALL PROVIDE (3) COPIES OF THE WORKING DRAWINGS, CALCULATIONS, A COMPLETED PERMIT APPLICATION AND APPROPRIATE FEES TO THE FIRE DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO BEGINNING OF WORK. D. THE FIRE DISTRICT MUST ISSUE A PERMIT PRIOR TO THE INSTALLATION OF THE FIRE SPRINKLER SYSTEM. E. THE SPRINKLER CONTRACTOR MUST HAVE A CITY BUSINESS LICENSE AND WORKER'S COMPENSATION CERTIFICATE. F. A FLAT CEILING IS REQUIRED IN AREAS INCORPORATING AN AUTOMATIC FIRE SPRINKLER SYSTEM TO ASURE PROPER FUNCTIONING OF THE SPRINKLER HEADS. FIRE DEPARTMENT NOTES A. CLASS 'A' ROOF ASSEMBLY IS REQUIRED. SEE PROVIDED DETAILS ON AD SHEETS. B. MIN. 1/2" SPARK ARRESTOR SHALL BE PROVIDED FOR EACH CHIMNEY. C. COMBUSTIBLE VEGETATION SHALL BE REMOVED WITHIN 30FT TO 100FT. OF STRUCTURE AND BE IN COMPLIANCE WITH CBC SEC 701A.3.2.4 PRIOR TO PROJECT FINAL APPROVAL. WATER SUPPLY REQUIREMENTS POTABLE WARER SUPPLIES SHALL BE PROTECTED FROM CONTAMINATION CAUSED BY FIRE PROTECTION WATER SUPPLIES. IT IS THE RESPONSIBILITY OF THE APPLICANT AND ANY CONTRACTORS AND SUBCONTRACTORS TO CONTACT THE WATER PURVEYOR SUPPLYING THE SITE OF SUCH PROJECT, AND TO COMPLY WITH THE REQUIREMENTS OF THAT PURVEYOR. SUCH REQUIREMENTS SHALL BE INCORPORATED INTO THE DESIGN OF ANY WATER-BASED FIRE PROTECTION SYSTEMS, AND/OR FIRE SUPPRESSION WATER SUPPLY SYSTEMS OR STORAGE CONTAINERS THAT MAY BE PHYSICALLY CONNECTED IN ANY MANNER TO AN APPLIANCE CAPABLE OF CAUSING CONTAMINATION OF THE POTABLE WATER SUPPLY OF THE PURVEYOR OF RECORD. FINAL APPROVAL OF THE SYSTEM(S) UNDER CONSIDERATION WILL NOT BE GRANTED BY THE FIRE DEPARTMENT UNTIL COMPLIANCE WITH THE REQUIREMENTS OF THE WATER PURVEYOR OF RECORD ARE DOCUMENTED BY THAT PURVEYOR AS HAVING BEEN MET BY THE APPLICANT(S). CONSTRUCTION SITE FIRE SAFETY ALL CONSTRCUTION SITES MUST COMPLY WITH APPLICABLE PROVISIONS OF THE CFC CHAPTER 33 AND THE FIRE DEPARTMENT'S STANDARD DETAIL AND SPECIFICATION SI-7. PROVIDE APPROPRIATE NOTATIONS ON SUBSEQUENT PLAN SUBMITTALS, AS APPROPRIATE TO THE PROJECT. CFC CHP.33 G. THE BUILDING SHALL BE PROVIDED WITH AN AUTOMATIC FIRE EXTINGUISHING SYSTEM. SPRINKLER CONTROL VALVES SHALL BE LOCATED TO ALLOW CONTROL OF THE SPRINKLER RISER FROM OUTSIDE THE BUILDING. SUBMIT SHOP DRAWINGS (3 SETS) AND A PERMIT APPLICATION TO THE FIRE PREVENTION DIVISION FOR REVIEW AND APPROVAL BEFORE INSTALLING THE SYSTEM. CALL (408) 378- 4010 FOR MORE INFORMATION. SMOKE ALARMS PER CBC #907.2.9.2, SMOKE ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH CBC #907.2.11. EGRESS DOORS EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, THUMB TURN, OR ANY SPECIAL KNOWLEDGE OR EFFORT. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED, UNLESS ANY OF THE EXCEPTIONS TO THE SECTION 1008.1.9.4 ARE MET. (CBC #1008.1.9) PREMISES IDENTIFICATION / PROJECT ADDRESS APPROVED NUMBERS OR ADDRESSES SHALL BE PLACED ON ALL NEW AND EXISTING BUILDINGS IN SUCH A POSITION AS TO BE PLAINLY LEGIBLE AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. SAID NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, ADDRESS NUMBERS SHALL BE ARABIC NUMBERS OR ALPHABETICAL LETTERS. NUMBERS SHALL BE A MINIMUM OF 4 INCHES HIGH WITH A MINIMUM STROKE OF 0.5 INCH. (CFC/505.1) WILDLAND / URBAN INTERFACE FIRE AREA THIS PROJECT IS LOCATED WITHIN THE DESIGNATED WILDLAND URBAN INTERFACE AREA. THE BUILDING CONSTRUCTION SHALL COMPLY WITH THE PROVISIONS OF THE CALIFORNIA BUILDING CODE (CBC) CHAPTER 7A. & R327 THE FOLLOWING CONDITIONS SHALL APPLY: A- 1.2 SITE CROSS SECTION OVERALL SITE PLAN C- 8.0 EASEMENT DISPOSITION PLAN C- 7.0 SITE CROSS SECTIONS 3,315 5,433 736-400=336 228 5,997 REALIGNMENT OF AN EXISTING EMERGENCY VEHICLE ACCESS EASEMENT LANDSCAPE ARCHITECT JENNA BAYER GARDEN DESIGN, INC. CONTACT: JENNA BAYER 1954 OLD MIDDLEFIELD WAY STE. B MOUNTAIN VIEW, CALIFORNIA 94043 (650) 988-9600 PHONE PLANTING PLANL- 6 EXHIBIT 15 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : C-1.0 Coker Residence PC2 6-30-17.pln7/5/20174:02 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 PROJECT SITE D.Z. A.B. A.C. B.C. B.O. B.V.C. C.B. C.L. C.O. CONT. D.I.P. D.S. D/W E.C. ELEV. E. E.V.C. F.F. F.G. F.H. F.C. F.L. F.S. AGGREGATE BASE ASPHALT CONCRETE BOTTOM OF CURB BLOW OFF BEGINNING OF VERTICAL CURVE CATCH BASIN CENTERLINE CLEAN OUT CONTINUOUS DUCTILE IRON PIPE DOWN SPOUTS DRIVEWAY END OF CURVE (HORIZONTAL) ELEVATION EXISTING END OF VERTICAL CURVE FINISHED FLOOR ELEVATION FINISHED GRADE FIRE HYDRANT FACE OF CURB FLOW LINE FINISHED SURFACE MIN. MON. M.V.C. N.T.S. P. P.C.C. P.C.R. P.V.C. P.V.I. R R.C.P. R/W S MINIMUM MONUMENT MIDDLE OF VERTICAL CURVE NOT TO SCALE PROPOSED PORTLAND CEMENT CONCRETE POINT ON CURB RETURN POLYVINYL CHLORIDE POINT OF VERTICAL INTERSECTION RADIUS REINFORCED CONCRETE PIPE RIGHT OF WAY SLOPE RESIDENCE AND PORCH(S) ROOF AREA ACCESSORY BLDG. PORCH(S) ROOF AREA WALKS /STAIR/LIGHTWELL POOL & SPA TOTAL IMPERVIOUS COVERAGE GRADE BREAK GATE VALVE HIGH POINT INSIDE DIAMETER INVERT LINEAR FEET LOW POINT MAXIMUM MANHOLE G.B. G.V. H.P. I.D. INV. L.F. L.P. MAX. M.H. STORM DRAIN STORM DRAIN MANHOLE SQUARE FEET SHEET SANITARY SEWER SANITARY SEWER MANHOLE STANDARD SIDEWALK TOP OF CURB TOP OF RETAINING WALL TYPICAL UNLESS NOTED OTHERWISE VERTICAL CURVE VITRIFIED CLAY PIPE WATER WATER METER WATER VALVE WATER SERVICE S.D. S.D.M.H. S.F. SHT. S.S. S.S.M.H. STD. S/W T.C. TW TYP. U.N.O. V.C. V.C.P. W W.M. W.V. W.S. VICINITY MAP TOWN OF LOS GATOS - OTHER STANDARD GRADING NOTES 6. EXCAVATED MATERIAL SHALL BE PLACED IN THE FILL AREAS DESIGNATED OR SHALL BE HAULED AWAY FROM THE SITE TO BE DISPOSED OF AT APPROVED LOCATION(S). 8. ALL GRADING SHALL BE PERFORMED IN SUCH A MANNER AS TO COMPLY WITH THE STANDARDS ESTABLISHED BY THE AIR QUALITY MANAGEMENT DISTRICT FOR AIRBORNE PARTICULATES. 11. HORIZONTAL AND VERTICAL CONTROLS SHALL BE SET AND CERTIFIED BY A LICENSED SURVEYOR OR REGISTERED CIVIL ENGINEER QUALIFIED TO PRACTICE LAND SURVEYING, FOR THE FOLLOWING ITEMS: a. RETAINING WALL: TOP OF WALL ELEVATIONS AND LOCATIONS (ALL WALLS TO BE PERMITTED SEPARATELY AND APPLIED FOR AT THE TOWN OF LOS GATOS BUILDING DIVISION). b. TOE AND TOP OF CUT AND FILL SLOPES. 12. PRIOR TO ISSUANCE OF ANY PERMIT, THE APPLICANT'S SOILS ENGINEER SHALL REVIEW THE FINAL GRADING AND DRAINAGE PLANS TO ENSURE THAT DESIGNS FOR FOUNDATIONS, RETAINING WALLS, SITE GRADING, AND SITE DRAINAGE ARE IN ACCORDANCE WITH THEIR RECOMMENDATIONS AND THE PEER REVIEW COMMENTS. THE APPLICANT'S SOILS ENGINEER'S APPROVAL SHALL THEN BE CONVEYED TO THE TOWN EITHER BY LETTER OR BY SIGNING THE PLANS. SOILS ENGINEER APPLIED WATER RESOURCES, CORP., DATED NOVEMBER 9, 2015 SHALL BE THOROUGHLY COMPLIED WITH. BOTH THE MENTIONED REPORT AND ALL UPDATES/ADDENDUMS/ LETTERS ARE HEREBY APPENDED AND MADE A PART OF THIS GRADING PLAN. 13. DURING CONSTRUCTION, ALL EXCAVATIONS AND GRADING SHALL BE INSPECTED BY THE APPLICANT'S SOILS ENGINEER. THE ENGINEER SHALL BE NOTIFIED AT LEAST FORTY-EIGHT (48) HOURS BEFORE BEGINNING ANY GRADING. THE ENGINEER SHALL BE ON-SITE TO VERIFY THAT THE ACTUAL CONDITIONS ARE AS ANTICIPATED IN THE DESIGN-LEVEL GEOTECHNICAL REPORT AND/OR PROVIDE APPROPRIATE CHANGES TO THE REPORT RECOMMENDATIONS, AS NECESSARY. ALL UNOBSERVED AND/OR UNAPPROVED GRADING SHALL BE REMOVED AND REPLACED UNDER SOILS ENGINEER OBSERVANCE (THE TOWN INSPECTOR SHALL BE MADE AWARE OF ANY REQUIRED CHANGES PRIOR TO WORK BEING PERFORMED). 16. THE CONTRACTOR SHALL INSTALL AND MAINTAIN FENCES, BARRIERS, LIGHTS AND SIGNS THAT ARE NECESSARY TO GIVE ADEQUATE WARNING AND/PROTECTION TO THE PUBLIC AT ALL TIMES. 21. WATER SHALL BE AVAILABLE ON THE SITE AT ALL TIMES DURING GRADING OPERATIONS TO PROPERLY MAINTAIN DUST CONTROL. 22. THIS PLAN DOES NOT APPROVE THE REMOVAL OF TREES. APPROPRIATE TREE REMOVAL PERMITS AND METHODS OF TREE PRESERVATION SHALL BE REQUIRED. TREE REMOVAL PERMITS ARE REQUIRED PRIOR TO THE APPROVAL OF ALL PLANS. 23. A TOWN ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY. A STATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK WITHIN STATE RIGHT-OF-WAY (IF APPLICABLE). THE PERMITTEE AND/OR CONTRACTOR SHALL BE RESPONSIBLE COORDINATING INSPECTION PERFORMED BY OTHER GOVERNMENTAL AGENCIES. 24. NO CROSS-LOT DRAINAGE WILL BE PERMITTED WITHOUT SATISFACTORY STORMWATER ACCEPTANCE DEED/FACILITIES. ALL DRAINAGE SHALL BE DIRECTED TO THE STREET OR OTHER ACCEPTABLE DRAINAGE FACILITY VIA A NON-EROSIVE METHOD AS APPROVED BY THE TOWN ENGINEER. 25. IT IS THE RESPONSIBILITY OF CONTRACTOR AND/OR OWNER TO MAKE SURE THAT ALL DIRT TRACKED INTO THE PUBLIC RIGHT-OF-WAY IS CLEANED UP ON A DAILY BASIS. MUD, SILT, CONCRETE AND OTHER CONSTRUCTION DEBRIS SHALL NOT BE WASHED INTO THE TOWN'S STORM DRAINS. 27. GRADING SHALL BE UNDERTAKEN IN ACCORDANCE WITH CONDITIONS AND REQUIREMENTS OF THE PROJECT STORM WATER POLLUTION CONTROL PLAN AND/OR STORM WATER POLLUTION PREVENTION PLAN (SWPPP), THE TOWN OF LOS GATOS STORM WATER QUALITY MANAGEMENT PROGRAM, NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) AND ANY OTHER PERMITS/REQUIREMENTS ISSUED BY THE STATE OF CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD. PLANS (INCLUDING ALL UPDATES) SHALL BE ON-SITE AT ALL TIMES. NO DIRECT STORMWATER DISCHARGES FROM THE DEVELOPMENT WILL BE ALLOWED ONTO TOWN STREETS OR INTO THE PUBLIC STORM DRAIN SYSTEM WITHOUT TREATMENT BY AN APPROVED STORM WATER POLLUTION PREVENTION DEVICE OR OTHER APPROVED METHODS. MAINTENANCE OF PRIVATE STORMWATER POLLUTION PREVENTION DEVICES SHALL BE THE SOLE RESPONSIBILITY OF THE OWNER. DISCHARGES OR CONNECTION WITHOUT TREATMENT BY AN APPROVED AND ADEQUATELY OPERATING STORMWATER POLLUTION PREVENTION DEVICE OR OTHER APPROVED METHOD SHALL BE CONSIDERED A VIOLATION OF THE ABOVE REFERENCED PERMIT AND THE TOWN OF LOS GATOS STORMWATER ORDINANCE. TOWN OF LOS GATOS NPDES NOTES 1. SEDIMENT FROM AREAS DISTURBED BY CONSTRUCTION SHALL BE RETAINED ON SITE USING STRUCTURAL CONTROLS AS REQUIRED BY THE STATEWIDE GENERAL CONSTRUCTION STORMWATER PERMIT. 2. STOCKPILES OF SOIL SHALL BE PROPERLY CONTAINED TO MINIMIZE SEDIMENT TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES OR ADJACENT PROPERTIES VIA RUNOFF, VEHICLE TRACKING, OR WIND AS REQUIRED BY THE STATEWIDE GENERAL CONSTRUCTION STORMWATER PERMIT. 3. APPROPRIATE BEST MANAGEMENT PRACTICES (BMPS) FOR CONSTRUCTION-RELATED MATERIALS, WASTES, SPILL OR RESIDES SHALL BE IMPLEMENTED TO MINIMIZE TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES, OR ADJOINING PROPERTY BY WIND OR RUNOFF AS REQUIRED BY THE STATEWIDE GENERAL CONSTRUCTION STORMWATER PERMIT. 4. RUNOFF FROM EQUIPMENT AND VEHICLE WASHING SHALL BE CONTAINED AT CONSTRUCTION SITES AND MUST NOT BE DISCHARGED TO RECEIVING WATERS OR TO THE LOCAL STORM DRAIN SYSTEM. 5. ALL CONSTRUCTION CONTRACTOR AND SUBCONTRACTOR PERSONNEL ARE TO BE MADE AWARE OF THE REQUIRED BEST MANAGEMENT PRACTICES (BMPS) AND GOOD HOUSEKEEPING MEASURES FOR THE PROJECT SITE AND ANY ASSOCIATED CONSTRUCTION STAGING AREAS. 6. AT THE END OF EACH DAY OF CONSTRUCTION ACTIVITY, ALL CONSTRUCTION DEBRIS AND WASTE MATERIALS SHALL BE COLLECTED AND PROPERLY DISPOSED IN TRASH OR RECYCLE BINS. 7. CONSTRUCTION SITES SHALL BE MAINTAINED IN SUCH A CONDITION THAT A STORM DOES NOT CARRY WASTE OR POLLUTANTS OFF OF THE SITE. DISCHARGES OF MATERIAL OTHER THAN STORMWATER (NON-STORMWATER DISCHARGES) ARE PROHIBITED EXCEPT AS AUTHORIZED BY AN INDIVIDUAL NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT OR THE STATEWIDE GENERAL CONSTRUCTION STORMWATER PERMIT. POTENTIAL POLLUTANTS INCLUDE BUT ARE NOT LIMITED TO: SOLID OR LIQUID CHEMICAL SPILLS; WASTES FROM PAINTS, STAINS, SEALANTS, SOLVENTS, DETERGENTS, GLUES, LIME, PESTICIDES, HERBICIDES, FERTILIZERS, WOOD PRESERVATIVES AND ASBESTOS FIBERS, PAINT FLAKES OR STUCCO FRAGMENTS; FUELS, OILS, LUBRICANTS, AND HYDRAULIC, RADIATOR OR BATTERY FLUIDS; CONCRETE AND RELATED CUTTING OR CURING RESIDUES; FLOATABLE WASTES; WASTES FROM ENGINE/EQUIPMENT STEAM CLEANING OR CHEMICAL DEGREASING; WASTES FROM STREET CLEANING; AND SUPERCHLORINATED POTABLE WATER FROM LINE FLUSHING AND TESTING. DURING CONSTRUCTION, DISPOSAL OF SUCH MATERIALS SHOULD OCCUR IN A SPECIFIED AND CONTROLLED TEMPORARY AREA ON-SITE PHYSICALLY SEPARATED FROM POTENTIAL STORMWATER RUNOFF, WITH ULTIMATE DISPOSAL IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REQUIREMENTS. 8. DISCHARGING CONTAMINATED GROUNDWATER PRODUCED BY DEWATERING GROUNDWATER THAT HAS INFILTRATED INTO THE CONSTRUCTION SITE IS PROHIBITED. DISCHARGING OF CONTAMINATED SOILS VIA SURFACE EROSION IS ALSO PROHIBITED. DISCHARGING NON- CONTAMINATED GROUNDWATER PRODUCED BY DEWATERING ACTIVITIES REQUIRES A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT FROM THE RESPECTIVE STATE REGIONAL WATER QUALITY CONTROL BOARD. COKER RESIDENCE ABBREVIATIONS ASSESSORS PARCEL NO. 537-33-009 TOWN NOTES, PROJECT DATA AND LEGEND TOWN OF LOS GATOS STANDARD PUBLIC IMPROVEMENT AND STANDARD GRADING NOTES 1. ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH THE FOLLOWING: a. TOWN OF LOS GATOS ENGINEERING DESIGN STANDARDS AND SPECIFICATIONS (UNLESS SPECIFICALLY STATED OTHERWISE ON THE PLANS). b. ALL TOWN OF LOS GATOS CONDITIONS OF APPROVAL RELATED TO THE PROJECT. c. THESE PLANS AND DETAILS. d. RECOMMENDATIONS OF THE PROJECT SOILS INVESTIGATION SOILS ENGINEER APPLIED WATER RESOURCES, CORP., DATED NOVEMBER 9, 2015 SHALL BE THOROUGHLY COMPLIED WITH. BOTH THE MENTIONED REPORT AND ALL UPDATES/ADDENDUMS/LETTERS ARE HEREBY APPENDED AND MADE A PART OF THESE PLANS. 2. NO WORK MAY BE STARTED ON-SITE WITHOUT AN APPROVED GRADING PLAN AND A GRADING PERMIT ISSUED BY THE TOWN OF LOS GATOS, PARKS AND PUBLIC WORKS DEPARTMENT LOCATED AT 41 MILES AVENUE, LOS GATOS, CA 95030. 3. A PRE-JOB MEETING SHALL BE HELD WITH THE TOWN ENGINEERING INSPECTOR FROM THE PARKS AND PUBLIC WORKS DEPARTMENT PRIOR TO ANY WORK BEING DONE. THE CONTRACTOR SHALL CALL THE INSPECTIONS LINE AT (4080 399-5771 AT LEAST FORTY-EIGHT (48) HOURS PRIOR TO ANY GRADING OR ONSITE WORK. THIS MEETING SHOULD INCLUDE: a. A DISCUSSION OF THE PROJECT CONDITIONS OF APPROVAL, WORKING HOURS, SITE MAINTENANCE AND OTHER CONSTRUCTION MATTERS; b. ACKNOWLEDGEMENT IN WRITING THAT CONTRACTOR AND APPLICANT HAVE READ AND UNDERSTAND THE PROJECT CONDITIONS OF APPROVAL, AND WILL MAKE CERTAIN THAT ALL PROJECT SUB-CONTRACTORS HAVE READ AND UNDERSTAND THEM PRIOR TO COMMENCING WORK AND THAT A COPY OF THE PROJECT CONDITIONS OF APPROVAL WILL BE POSTED ON SITE AT ALL TIMES DURING CONSTRUCTION. 4. APPROVAL OF PLANS DOES NOT RELEASE THE DEVELOPER OF THE RESPONSIBILITY FOR THE CORRECTION OF MISTAKES, ERRORS, OR OMISSIONS CONTAINED THEREIN. IF, DURING THE COURSE OF CONSTRUCTION OF THE IMPROVEMENTS, PUBLIC INTEREST AND SAFETY REQUIRES A MODIFICATION OR DEPARTURE FROM THE TOWN SPECIFICATIONS OR THESE IMPROVEMENT PLANS, THE TOWN ENGINEER SHALL HAVE FULL AUTHORITY TO REQUIRE SUCH MODIFICATION OR DEPARTURE AND TO SPECIFY THE MANNER IN WHICH THE SAME IS TO BE MADE. 5. APPROVAL OF THIS PLAN APPLIES ONLY TO THE GRADING, EXCAVATION, PLACEMENT, AND COMPACTION OF NATURAL EARTH MATERIALS. THIS APPROVAL DOES NOT CONFER ANY RIGHTS OF ENTRY TO EITHER PUBLIC PROPERTY OR THE PRIVATE PROPERTY OF OTHERS AND DOES NOT CONSTITUTE APPROVAL OF ANY OTHER IMPROVEMENTS. 6. IT SHALL BE THE RESPONSIBILITY OF THE PERMITTEE OR CONTRACTOR TO IDENTIFY, LOCATE AND PROTECT ALL UNDERGROUND FACILITIES. PERMITTEE OR CONTRACTOR SHALL NOTIFY USA (UNDERGROUND SERVICE ALERT) AT 1-800-227-2600 A MINIMUM OF FORTY-EIGHT (48) HOURS BUT NOT MORE THAN FOURTEEN (14) DAYS PRIOR TO COMMENCING ALL WORK. 7. ALL WORK SHALL BE PERFORMED IN SUCH A MANNER AS TO COMPLY WITH THE STANDARDS ESTABLISHED BY THE AIR QUALITY MANAGEMENT DISTRICT FOR AIRBORNE PARTICULATES. 8. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL LAWS, CODES, RULES AND REGULATIONS GOVERNING THE WORK IDENTIFIED ON THESE PLANS. THESE SHALL INCLUDE, WITHOUT LIMITATION, SAFETY AND HEALTH RULES AND REGULATIONS ESTABLISHED BY OR PURSUANT TO THE OCCUPATIONAL SAFETY AND HEALTH ACT OR ANY OTHER APPLICABLE PUBLIC AUTHORITY. 9. THE GENERAL CONTRACTOR SHALL PROVIDE QUALIFIED SUPERVISION ON THE JOB SITE AT ALL TIMES DURING CONSTRUCTION. 10. CONTRACTOR SHALL EXERCISE ALL NECESSARY CAUTION TO AVOID DAMAGE TO ANY EXISTING TREES, SURFACE IMPROVEMENTS, DRAINAGE, WATER, SEWER, ELECTRICAL OR TELECOMMUNICATION FACILITIES WHETHER ABOVE GROUND OR UNDERGROUND. CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR ANY DAMAGE THERETO. 11. HORIZONTAL AND VERTICAL CONTROLS SHALL BE SET AND CERTIFIED BY A LICENSED SURVEYOR OR REGISTERED CIVIL ENGINEER QUALIFIED TO PRACTICE LAND SURVEYING. 12. DURING CONSTRUCTION, ALL APPLICABLE WORK (SUBGRADE, PAVING, ETC.) SHALL BE INSPECTED BY THE APPLICANT'S SOILS ENGINEER. THE ENGINEER SHALL BE NOTIFIED AT LEAST 48 HOURS BEFORE BEGINNING SUCH WORK. THE ENGINEER SHALL BE ON-SITE TO VERIFY CONDITIONS AS REQUIRED IN HIS REPORT. SHOULD ANY CHANGES TO THE REPORT RECOMMENDATIONS BE NECESSARY, TOWN APPROVAL SHALL BE OBTAINED PRIOR TO ANY ASSOCIATED WORK. 13. THE RESULTS OF THE CONSTRUCTION OBSERVATION AND TESTING SHALL BE DOCUMENTED IN AN “AS-BUILT” LETTER/REPORT PREPARED BY THE APPLICANTS' SOILS ENGINEER AND SUBMITTED FOR THE TOWN'S REVIEW AND ACCEPTANCE BEFORE FINAL RELEASE OF ANY OCCUPANCY PERMIT IS GRANTED. 14. ALL PRIVATE AND PUBLIC STREETS ACCESSING PROJECT SITE SHALL BE KEPT OPEN AND IN A SAFE, DRIVABLE CONDITION THROUGHOUT CONSTRUCTION. IF TEMPORARY CLOSURE IS NEEDED, THEN FORMAL WRITTEN NOTICE TO THE ADJACENT NEIGHBORS AND THE TOWN OF LOS GATOS PARKS AND PUBLIC WORKS DEPARTMENT SHALL BE PROVIDED AT LEAST ONE WEEK IN ADVANCE OF CLOSURE, AND NO CLOSURE SHALL BE GRANTED WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE TOWN. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC OR PRIVATE RIGHT-OF-WAY. 15. THE CONTRACTOR SHALL INSTALL AND MAINTAIN FENCES, BARRIERS, LIGHTS AND SIGNS THAT ARE NECESSARY TO GIVE ADEQUATE WARNING AND PROTECTION TO THE PUBLIC AT ALL TIMES. 16. OWNER/APPLICANT: TOM SLOAN PHONE:(408) 871-1071 17. GENERAL CONTRACTOR: T.B.D. PHONE:T.B.D. 18. A TOWN ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK WITHIN THE PUBLIC RIGHT- OF-WAY. A STATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK WITHIN STATE RIGHT- OF-WAY (IF APPLICABLE). THE PERMITTEE AND/OR CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING INSPECTION PERFORMED BY OTHER GOVERNMENTAL AGENCIES. 19. GOOD HOUSEKEEPING PRACTICES SHALL BE OBSERVED AT ALL TIMES DURING THE COURSE OF CONSTRUCTION. SUPERINTENDENCE OF CONSTRUCTION SHALL BE DILIGENTLY PERFORMED BY A PERSON OR PERSONS AUTHORIZED TO DO SO AT ALL TIMES DURING WORKING HOURS. THE STORING OF GOODS AND/OR MATERIALS ON THE SIDEWALK AND/OR THE STREET WILL NOT BE ALLOWED UNLESS A SPECIAL PERMIT IS ISSUED BY THE ENGINEERING DIVISION. THE ADJACENT PUBLIC RIGHT-OF-WAY SHALL BE KEPT CLEAR OF ALL JOB RELATED DIRT AND DEBRIS AT THE END OF THE DAY. FAILURE TO MAINTAIN THE PUBLIC RIGHT-OF-WAY ACCORDING TO THIS CONDITION MAY RESULT IN PENALTIES AND/OR THE TOWN PERFORMING THE REQUIRED MAINTENANCE AT THE DEVELOPER'S EXPENSE. NO SCALE PLAN F0R THE IMPROVEMENT OF ARCHITECTURE AND SITE APPLICATION S-14-122 20102 FOSTER ROAD LOS GATOS, CA 95030 C-3.0 EROSION CONTROL PLAN C-2.0 TOPOGRAPHIC AND BOUNDARY SURVEY C-1.0 PRELIMINARY GRADING & DRAINAGE PLAN TOWN NOTES, PROJECT DATA, LEGEND & ABBREVIATIONS C-4.0 C-5.0 EROSION CONTROL DETAILS C-6.0 CONSTRUCTION DETAILS C-8.0 OVERALL SITE PLAN C-7.1 EASEMENT DISPOSITION PLAN SHEET INDEX THE GEOTECHNICAL CONSULTANT SHALL INSPECT, TEST (AS NEEDED), AND APPROVE ALL GEOTECHNICAL ASPECTS OF THE PROJECT CONSTRUCTION. THE INSPECTIONS SHOULD INCLUDE, BUT NOT NECESSARILY BE LIMITED TO: SITE PREPARATION AND GRADING, SITE SURFACE AND SUBSURFACE DRAINAGE IMPROVEMENTS AND EXCAVATIONS FOR FOUNDATIONS AND RETAINING WALLS PRIOR TO THE PLACEMENT OF STEEL AND CONCRETE. THE CONSULTANT SHALL VERIFY THAT FILL MATERIALS PLACED ON SLOPING GROUND ARE PROPERLY KEYED AND BENCHED INTO SUPPORTIVE MATERIALS, AS NECESSARY. NOTE: GEOTECHNICAL FIELD INSPECTION TOPO SURVEY & BOUNDARIES KIER & WRIGHT CIVIL ENGINEERS & SURVEYORS, INC. 3350 SCOTT BOULEVARD, BUILDING 22 SANTA CLARA, CA 95054 (408) 727-6665 PHONE (408) 727-5641 FAX GEOTECHNICAL ENGINEERING APPLIED WATER RESOURCES, CORP. 1046 WEST TAYLOR STREET, SUITE 105 SAN JOSE, CA 95126 (408) 496 0801 PHONE SITE CROSS SECTIONS C-7.0 PROPOSED PERVIOUS AND IMPERVIOUS AREAS TOTAL SITE AREA TOTAL SITE AREA DISTURBED: (INCLUDING CLEARING, GRADING OR EXCAVATING)29,465 SQ. FT. TOTAL IMPERVIOUS AREA:11,560 SQ. FT. PERVOIUS AREA:17,905 SQ. FT. 8,621 SQ. FT. 707 SQ. FT. 1,491 SQ. FT. 741 SQ. FT. 11,560 SQ. FT. GROSS: 166,815 SQ. FT. (3.83 AC) NET: 66,726 SQ. FT. (1.53AC) METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : C-2.0 Coker Residence PC2 6-30-17.pln7/5/20174:02 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 030'60'20'-0"25'-0"30'-0"15'-0"22'-6"30'-31/2"25'-9"127'-9"99'-2"185'-101/2"199'-1"INDICATES 20' WIDE EASEMENTFOR EMERGENCY VEHICLEINDICATES 12' WIDE PROPOSEDEMERGENCY VEHICLE ACCESS ROADWITH Grasspave2INDICATES EXISTINGEMERGENCY VEHICLEACCESS ROADINDICATES LRDA(SLOPE UNDER 30 %) -TYP.4" HDPE 6 " HDPE6" HDPE~ 8 " H D P E SS 6"HDPE~~6 " HDPE SS 4" 6"8" HDPE15"HD P E SD SD 15"HD P E SD 1 5 " H D P E12" PVCGravelGRAVEL ROADFO FO Very Dense TreesVery Dense TreesGrassAsphaltAsph.PileRockDirt Ro a d RocksDirtAsphaltGate704.6GRN712.2TOP713.7TOP705.0GRN705.9GRN706.68WMTB 706 .30 BC 706 .05 FL 706 .07 LIP EVTB EB 707 .81 BC 707 .60 FL 707 .61 LIP 702 .36 BC 702 .11 FL 702 .14 LIP 700.65 BC700.39 FL700.42 LIP695.06SIGN696 .42 BC 696 .19 FL 696 .20 LIP696.13BC696.66LIP686.21 PV686.71 BC683.74 BC683.14 PVSLB696 .60 CATV SLBSL689.16BC682.35 BC681.91 FL681.98 LIP650.50 BC650.08 FL650.15 LIP627.38BC627.71PV635.28 BC634.79 FL634.91 LIP681.5GRN682.67CO676.0GRN668.0GRN662.2GRN655.2GRNFHEB645.02WV(3)641.96BC629.59PP613.24BC604.84PV605.32 BC610.05 PPVG608.52623.40CO623.51 WALL693.80WALL691.26WALL634.41WALL635.77WV(3)632.58BC BEG634.51BC632.45BCOHOHOHOH~~~WWWSDW6" HDPE SS 4"WWM (PP)~~~636.12BCEV717.0TOP GB604.73 BC603.8712" PIPE622.62BC622.76 BC622.29 FL622.41 LIP643.88 BC643.45 FL643.62 LIP650.48BC646.6GRN646.76BC~704.36DIINV 701.16 12"704.45CB-TCINV 700.75 12"INV 700.73 15"703 .27 BC 703 .01 FL 703 .10 LIP 699.43 BC 699.18 FL699.21 LIP691.58 BC690.88 PV691.34 BC690.88 FL690.94 LIP678.65BC672.83BCPV665.70666.05BC667.12 BC666.64 FL666.75 LIPWALL667.25669.15WALL635.31 PUMP STATION8" HD P E 15"HD P E 697.60BC666.05BC650.50WALL638.2GRN627.62 BC627.10 FL627.22 LIP707 .67 FW 707 .67 FW706.62FH(2 ) WV 703 .51 WV WALL682.10651.75WALL631.77PP630.97WALL651.75WALL6"6" ~WSSW S S 4 "4"W 6 " WATER ~2"4 "8" & 2" W 8 " & 2 " WATER 1 5 "4"JT 8 " & 2 " WA T E R 4"15"SD15"SDJTJTJT15"2"730.22"731.2N83°33'55"E21.93'N78°50'21"E20.49'N79°57'46"E16.63'S 1 3 °1 9 '3 5 "E 3 8 .6 8 ' S 0 0 ° 1 5 ' 2 7 "W7 4 . 3 9 ' S 0 4 ° 0 4 '2 4 " E 8 7 . 7 5 'N53°38'34"E28.19'N16°09'36"E352.81'N23 °19'50"W 13 6 .53' N36°06'47"W37.35'S47°05'49"W65.48'N41°51'11"W60.06' N 67 °20 '11 "W 17 .82 'S72°39'49"W36.96'N0 0 ° 1 5 ' 5 2 "W5 7 . 6 0 'S74°18'28"W92.40'N56°37'08"W 70.55' N 75 °56 '32 "W 34 .32 'S47°49'45"W36.48'N76°56'26"E158.55' N76°03'42"E47.41' N 71 °56 '26 " W 17 8 .26 ' S 75 °04 '42 "E 35 .39 ' L=18.56'R=98.22 =10°49'30" ” SD SS SS74 0 73 5 73 0 7 2 5 615 620 625 63 0 635 640 64 5 650 655 66 0 66 5 67 0 67 5 68 0 68 5 69 0 695 700 705 710 715 720 600 610620 630 640 650 660 670 680 690 700 710 720 715710705700695690725 730620630640650715 720 60061062063064065066067068063062061060074073072073074072 5 7 3 0 7 3 5 7 4 0 12" OAK12" OAKFOSTERROADUPUPSIDESETBACK LINEFRONT SETBACK LINEPRIVATESTORMDRAINAGEEASEMENTREARSETBACK LINEL O T 6 GRAPHIC SCALE: (IN FEET) INDICATES AREA LIMIT LINE (SLOPE OVER 30 %) -TYP. 537-03-043 BARTLETT 537-03-073 BARTLETT 537-03-072 DINAPOLI 537-03-012 CAIRNS LOT 2 BRADY LOT 1 SINGH LOT 5 RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIALRESIDENTIAL 537-03-072 DINAPOLI RESIDENTIAL537-02-012 CALIFORNIA PROVINCE OF SOCIETY OF JESUS 537-02-009 MID PENINSULA REGIONAL OPEN SPACE DISTRICT McCARTHY 537-03-045 RESIDENTIALN 00°09'11" E304.71'S 47 °35 '39 "W 5 .07 ' N N/A 1" = 30'-0" SITE LEGEND OVERALL SITE PLAN LOT 6 -TRACT 9368 SCALE: 1" = 30'-0" OVERALL SITE PLAN LOT 6 -TRACT 9368 METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : C-4.0 Coker Residence PC2 6-30-17.pln7/5/20174:02 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 N2 3 4 1 7 6 3 C-7.0 6 20'-0"30'-0"22'-6"10'-0"13'-31/2"R 42'R 30' R 30'R 42'FG=721.33 FS=722.00'FS=721.75' FS=720.75' FS=720.67' 29 LF - 4" SCH 40 P.V.C. S=0.02 47.5 LF - 4" SCH 40 P.V.C. S=0.02 FG=721.33 FG=720.00 FL=722.50' FL=724.00' FL=721.70' FL=721.36' FS=722.00' FS=722.06' FS=722.21' FS=722.27' FS=721.83' FS=721.69' RIM @ RETENTION POND=721.00' FL=721.00' FG=722.50' FL=719.50'FL=718.17' FG=721.33 FG=721.33 FG=722.05' CB2 CB1 CB3 CB5 CB6 CB7 CB8 34 LF - 4" SCH 40 P.V.C. S=0.16 SDMH CB9 CB10 CB11 8 LF - 4" SCH 40 P.V.C. S=0.02 54 LF - 4" SCH 40 P.V.C. S=0.01 CO 5' POOL WALL TW=719.33' BW=719.00 TW=713.58' BW=710.58' TW=722.50' BW=713.00' TW=725.00' BW=721.83 TW=720.50' BW=716.67' COPING=720.50' FG=721.33 FG=721.33 FG=721.33FIRE SPRINKLER RISER CONFORM TO EXISTING PAVED CURB CONFORM TO EXISTINGPAVED CURB CO N F O R M TO EXI S T I N G PA V E D CU R B EXISTING ROLLED CURB TO REMAIN ENCROACHMENT PERMIT REQUIRED FOR PAVERS PERVIOUS PAVERS @ DRIVEWAY FS=721.67' FS=721.67' FG=721.81' TW=725.00' BW=722.00' TW=723.75' BW=721.83' TW=719.00' BW=710.58' TW=722.50' BW=721.00' FS=721.75' FS=721.83' FS=721.83' FS=721.75' FS=721.83' FS=721.75' STORM WATER EASEMENT FG=721.13 FG=721.13 FG=721.33 FS=720.50 FG=716.67 FS=720.50 FG=716.67 FG=721.68 FS=721.83'FS=721.83' FG=720.64 TC=716.28 TC=716.34 FS=721.83' FS=721.75' 155 LF - 4" SCH 40 P.V.C. S=0.01 INV = 705.00' OVERLAND RELEASE =720.50' CB4 TW=722.83' BW=721.83' TW=719.00' BW=710.58'INV =707.38' INDICATES 42' MINIMUM OUTSIDE TURNING RADIUS PER FIRE DEPARTMENT SCC -STANDARD DETAILS & SPECIFICATIONS SPEC NO A-1 (06/01/09) 5. INDICATES LRDA (SLOPE UNDER 30 %) -TYP. STA DW1 0+00' ELEV 716.64' STA DW2 0 + 31.70' ELEV.= 718.00' STA DW3 0+67.70' ELEV.= 718.00' STA DW4 0+86.19' ELEV.=717.00' STA DW5 0+101.06' ELEV.= 716.39' STA DW6 0+154.13' ELEV.=716.46' STA DW7 0+169.00' ELEV. = 717.00' STA DW8 0+180.92' ELEV. = 718.00' STA DW9 0+193.00' ELEV. = 719.00' STA DW10 0+206.34' ELEV. = 719.70' SSMH SDMH SDMH SSMH SSMH EXIST. STORM DRAIN, PRIVATE SANITARY SEWER & EMERGENCY ACCESS EASEMENT PROPOSED. STORM DRAIN, PRIVATE SANITARY SEWER & EMERGENCY ACCESS EASEMENT FG=721.33 FG=721.33FG=721.33 FG=721.33 FS=710.58' FS=710.58' 722.02'722.02' FS=721.83' FS=721.69' FG=721.33 FG=721.33 FG=721.33 FG=720.83 FG=719.00 FG=720.83 FS=720.83' FS=720.77' FS=720.77' FG=720.00 FG=720.00 FG=720.00 TW=719.33' BW=716.91 FG=716.58 TW=720.50 BW=717.37 TW=720.50' BW=716.67 TW=720.50' BW=715.50 TW=720.50' BW=715.50 TW=720.50' BW=716.67' TW=723.00' BW=721.81' TW=725.00' BW=722.00' FS=721.83' FS=716.20' FS=710.58' RIM @ RETENTION POND=721.00' 2' CONCRETE 'V' DITCH 6" DEEP SEE DET 13 / C-7.0 TW=719.00' BW=710.58' 2' WIDE DRAINAGE CHANNEL SEE DET 10/ C-7.0 26 LF - 4" SCH 40 P.V.C. S=0.02 74 LF - 4" SCH 40 P.V.C. S=0.02 CB 6 LF - 4" SCH 40 P.V.C. S=0.02 8 LF - 4" SCH 40 P.V.C. S=0.02 TW=713.58'BW=710.58' 29 LF - 4" SCH 40P.V.C. S=0.02 33 LF - 4" SCH 40P.V.C. S=0.01 TW=719.33' BW=718.00 TC=716.33' INDICATES AREA OF PERVIOUS PAVERS WITH IMPERMEABLE BARRIER WITHIN 10' FROM THE RESIDENCE -SEE DET. 7 &8/C-7.0 F O S T E R R O AD UP UP COURTYARD 3 - GARAGE COVERED VERANDA POOL COVERED VERANDA PLANTER PLANTER PLANTER PLANTER 2 % SLOPE ACCESSORY BUILDING FRONTSETBACK LINESIDE SETBA C K LINE POOL EQUIP.740735730725725720730 735730725715710715710N 71°56'26" W178.26'D=51°07'18"L=77.56'R =142 .91 ' Δ=77°24'59"L=193.10' (Δ=77°25'09") R=106.94' Δ=9°56'53" L=18.57' R =162 .91 ' Δ=77°36'48" L= 22 0 .68 ' N 00°09'11" E 304.71' S 4 7 °3 5 '3 9 " W 3 5 .3 1 ' L = 3 6 .89 L=52.61 SPA 11" OAK 18" OAK 21" OAK 20" BAY 15" BLUE OAK 26" BLUE OAK GRADING PLAN LEGEND (E) GRADE MINOR CONTOUR LINE (E) GRADE MAJOR CONTOUR LINE PROPOSED GRADE CONTOUR LINE SAWCUT LINE, CONTRACTOR SHALL SAWCUT... RETAINING WALL, SEE STRUCTURAL PLAN FOR DETAILS EXTENT OF WORK AND GRADING LINE EXISTING TREE TO REMAIN PROPOSED RESIDENCE PROPOSED PERVIOUS PAVERS AT DRIVEWAY PROPOSED HARDSCAPE DECOMPOSITE GRANITE Grasspave2 @ EMERGENCY VEHICLE ACCESS ROAD EXISTING EMERGENCY VEHICLE ACCESS ROAD LANDSCAPE AREA, SEE LANDSCAPE PLANS FOR MORE DETAILS 20" BAY LOWER TERRACE 4" HDPE6" HDPE 8" HDPE~~6"6"15" HDPESD15" HDPESDSD15" HDPE8" HDPE WV WM RIM 723.09 SSCO 723 .4 ELEC . MARKER 723.80TB723.77FOB72 3 .47CA T V FOFO20 '-0 " 12 '-0 " NOTE:ALL EXISTING TREES TO REMAIN AND TO BE PROTECTED DURING CONSTRUCTION -TYP. FND. MON 720723F.S. = 722.0' PAD = 721.0' 720 721719718 717 719 718 SAWCUT F.S. = 722.0' PAD = 721.0' F.S. = 722.0' PAD = 721.0' DS DS DS DS DS DS DSDS DS DS DS DS DS DS DS DS DS DS DS RIM=720.65' INV=719.15' RIM=720.34' INV=718.57' 1 % SLOPE RIM=719.62' INV=717.62' FLOW LINE @ 1 % SLOPE RIM=721.08'INV=718.92'RIM=721.08'INV=719.58' RIM=721.50' INV=718.34'PLANTERRIM=717.50' INV=715.50' (E) RIM 720.13 INV 709.82 15" (OUT-NW) INV 709.87 15" (IN-E) RIM=718.00' INV=707.54' RIM=710.50' INV=707.50' RIM=710.50' INV=707.22' RIM=721.75' INV=706.68' OVERLAND RELEASE MAIN F.F. = 722.0' CELLAR F.S. = 710.75' PAD = 709.08' PROPOSED SINGLE STORY RESIDENCE INDICATES CELLAR LOCATION NEW FENCE NEW GAS LINE NEW WATER LINE NEW ELECTRIC LINE NEW JOINT TRENCH NEW SANITARY SEWER LINE EXISTING FENCE EXISTING GAS LINE EXISTING WATER LINE EXISTING ELECTRIC LINE EXISTING JOINT TRENCH EXISTING SANITARY SEWER LINE E G CO 4 " HDPE GRAPHIC SCALE: (IN FEET) 10 0 5 10 20 30NEW 2" WATERCONCRETE SLAB ON GRADE CONCRETE SLAB ON GRADE F.S. = 720.50 ' PAD = 719.67 ' E V A E 15'-0"RIM=719.50' INV=716.86' 717720722 700EXISTING 10' P.S.E. EASEMENT RIM 718.18 INV 711.00 6" (IN-SW) INV 698.18 6" (IN-N) INV 697.82 6" (OUT-NW) INV 698.38 6" (IN-E) INV 698.02 6" (IN-S) (E) RIM 720.33 (P) RIM 719.20 INV 695.44 8" (THRU) INV 712.05 15" (IN-E) INV 711.87 15" (OUT-W) INV 710.95 15" (IN-E) INV 710.75 15" (OUT-W) (E) RIM 720.75 (P) RIM 716.33 (E) RIM 721.79 (P) RIM 718.16 (E) RIM 721.68 (P) RIM 718.03 INV 697.36 (THRU) 731.23 RIP-RAP GRADE BREACK 731.79 RIP-RAP GRADE BREACK 734.51 RIP-RAP 734.71 RIP-RAP 721.45 RIP-RAP 720.93 RIP-RAP LIGHTWELL TC 716.48 INV 712.68 15" INV 712.63 15" INV 710.06 4" (IN-S) 721 71972 3 722 S1 A1.2 S2 A1.2 S3 A1.2 S4 A1.2 PERF. 4" DIA. SCHED. 40 P.V.C. PIPE SLOPED TO DRAIN MIN. 1/4" PER FOOT -TYP. SOLID 4" DIA. SCHED. 40 P.V.C. PIPE SLOPED TO DRAIN MIN. 1/8" PER FOOT -TYP. F.S. = 720.67 ' PAD = 719.67 ' GRADING & DRAINAGE PLAN DZ 1/10" = 1'-0" EXPORT DRIVEWAY TYPE OF WORK LOCATION PROPOSED CUT PROPOSED FILL HOUSE & ATTACHED GARAGE TOTAL TOTAL 0 CY LANDSCAPE N/A CY 123 CY PROPOSED EXCAVATION N/A CY N/A CY 0 CY 15 CY 260 CY 19 CY 111 CY 46 CY 306 CY EARTHWORK QUANTITIES N/A CY 123 CY 92 CY 15 CY POOL AND SPA ACCESSORY BLDG. 170 CY N/A CY 0 CY 170 CY 1,695 CY 981 CY 65 CY 2,405 CY 2,611 CY1,695 CY 981 CY 65 CY+-= NOTE: EARTH WORK QUANTITIES SHOWN ARE APPROXIMATE. IT SHALL BE CONTRACTOR'S RESPONSABILITY TO INDEPENDENTLY ESTIMATE QUANTITIES FOR HIS/HER OWN USE. MAX. RETAINING WALL = 4'-0" * TOTAL DISTURBED AREA: 29,465 SQ. FT. FIRE ROAD (EVAE EASEMENT) MAX. CUT MAX. FILL 2'-11"- 3'-0"9" ** 1'-0"- **EXCLUDES CELLARS PER HDSG SECTION III TABLE 1. 4'-0"1'-6" 336 CY336 CYN/A CY 4'-0"0 CY -*** CELLAR 1,525 CY N/A CY 0 CY 1,525 CY - ***EXCLUDES EXCAVATION FOR POOL PER HDSG SECTION III TABLE 1. -- -- 12'-9"LIGHTWELL 155 CYN/A CY 0 CY -155 CY METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : C-5.0 Coker Residence PC2 6-30-17.pln7/5/20174:02 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 3 2 3 4 1 7 6 20'-0"30'-0"22'-6"10'-0"FG=721.33 TREE PROTECTION FENCE THAT WILL BE REPLACED WITH A MAX. 6'-0" TALL WOOD FENCE WITH TOP AND BOTTOM RAIL AND 2 x 4 BROWN PVC VINYL COATED WELDED WIRE FENCING CONSTRUCTION ENTRANCE FIRE SPRINKLER RISER INDICATES LRDA (SLOPE UNDER 30 %) -TYP. EROSION CONTROL LEGEND STABILIZED ENTRANCE/EXIT CONCRETE WASHOUT SPILL KIT PORTABLE RESTROOM EXISTING EMERGENCY VEHICLE ACCESS ROAD 20" BAY SK FIBER ROLL INLET PROTECTION TREE PROTECTION FENCE NEW FENCE CONSTRUCTION FENCE INDICATES EXISTING TREE TO REMAIN NOTE:ALL EXISTING TREES TO REMAIN AND TO BE PROTECTED DURING CONSTRUCTION -TYP. F O S T E R R O AD UP UP COURTYARD 3 - GARAGE COVERED VERANDA POOL LAWN COVERED VERANDA PLANTER PLANTER PLANTER PLANTER 2 % SLOPE ACCESSORY BUILDING SIDE SETBA C K LINE POOL EQUIP.740735730725725720730 735730725715710715710N 71°56'26" W178.26'D=51°07'18"L=77.56'R =142 .91 ' Δ=77°24'59"L=193.10' (Δ=77°25'09") R =106.94 ' Δ=9°56'53" L=18.57' R =162 .91 ' Δ=77°36'48" L= 22 0 .68 ' N 00°09'11" E 304.71' S 4 7 °3 5 '3 9 " W 3 5 .3 1 ' L = 3 6 .89 L=52.61 SPA 11" OAK 18" OAK 21" OAK 20" BAY 15" BLUE OAK 26" BLUE OAK LOWER TERRACE 4" HDPE6" HDPE 8" HDPE~~6"6"15" HDPESD15" HDPESDSD15" HDPE8" HDPE WV WM RIM 723.09 SSCO 723 .4 ELEC . MARKER 723.80TB723.77FOB72 3 .47CA T V FOFO20 '-0 " 12 '-0 " FND. MON723 MAIN F.F. = 722.0' F.S. = 722.0' PAD = 721.0' F.S. = 720 .67' PAD = 719 .67' 720 718 717 718 CELLAR F.S. = 710.75' PAD = 709.08' F.S. = 722.0' PAD = 721.0' F.S. = 722.0' PAD = 721.0' DS DS DS DS DS DS DSDS DS DS DS DS DS DS DS DS DS DS DS 1 % SLOPE PLANTERSK PROPOSED SINGLE STORY RESIDENCE INDICATES CELLAR LOCATION E G CO 4" HDPE GRAPHIC SCALE: (IN FEET) 10 0 5 10 20 30NEW 2" WATER717720722 EXISTING 10' P.S.E. EASEMENT 720721719719 NPROPOSED EROSION CONTROL PLAN DZ 1/10" = 1'-0" METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : C-6.0 Coker Residence PC2 6-30-17.pln7/5/20174:02 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-172 3 4 1 8 7 6 20'-0"30'-0"22'-6" 5' POOL WALL UP UP COURTYARD 3 - GARAGE COVERED VERANDA POOL LAWN COVERED VERANDA PLANTER PLANTER PLANTER PLANTER 2 % SLOPE ACCESSORY BUILDING FRONT SETBACK LINESIDE SETBAC K LINE POOL EQUIP.740735730725725720730 735730725715710715710N 71°56'26" W178.26'R =142 .91 '(Δ=77°25'09") R=106.94' Δ=9°56'53" L=18.57' R =162 .91 ' Δ=77°36'48" N 00°09'11" E 304.71' S 47 °35 '39 " W 35 .31 ' L=52.61 SPA 11" OAK 18" OAK 21" OAK 20" BAY 13" BLUE OAK 15" BLUE OAK 26" BLUE OAK LOWER TERRACE 4" HDPE~8" HDPE~15" HDPESD15" HDPESDSD15" HDPE12" PVC 8" HDPE WV WM RIM 723.09 SSCO 723 .4 ELEC . MARKER 72 3 .47CA T V CO 20 '-0 " 12 '-0 "723F.S. = 722.0' PAD = 721.0' F.S. = 720.67' PAD = 719.67' 720 718 717 718720F.S. = 722.0' PAD = 721.0' F.S. = 722.0' PAD = 721.0' DS DS DS DS DS DS DSDS DS DS DS DS DS DS DS DS DS DS DSPLANTER OVERLAND RELEASE OVERLAND RELEASE OVERLAND RELEASE MAIN F.F. = 722.0' CELLAR F.S. = 710.75' PAD = 709.08' PROPOSED SINGLE STORY RESIDENCE GRAPHIC SCALE: (IN FEET) 10 0 5 10 20 30 720721719719 717 719 A C-7.0 A C-7.0 B C-7.0 B C-7.0 NPROPOSED GRADE EXISTING GRADE 12' WIDE PROPOSED E V A ROAD 20 FT WIDE EASEMENT FOR EMERGENCY VEHICLES INDICATES PROPOSED GRADE INDICATES EXISTING GRADEINDICATES EXISTING GRADE INDICATES PROPOSED GRADE 3 CAR GARAGE FS =722.00' TO 722.27' RESIDENCE FF = 722' 3'-11" PL BSL 720 CELLAR MAX. CUT 715 710 725 730 735 740 720 715 710 725 730 735 740 FS= 710.75' 15'-0" INDICATES PROPOSED FINISHED GRADE INDICATES EXISTING GRADE 2' WIDE DRAINAGE CHANNEL SEE DET 10/ C-7.0 PL BSL RESIDENCE FF = 722' FS=710.75' CELLAR 720 715 710 725 730 735 740 720 715 710 725 730 735 740 EP FOSTER ROAD PLBSL PSDE SECTION A-A SCALE : 1/8" = 1'-0" SCALE : 1/8" = 1'-0" SECTION B-B SITE CROSS SECTIONS DZ AS SHOWN CROSS SECTIONS LOCATION DIAGRAM SCALE : 1" = 20'-0" METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : C-7.0 Coker Residence PC2 6-30-17.pln7/5/20174:02 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 N.T.S. BUBBLER DETAIL Scale 1/2'' = 1' - 0'' LEADER TERMINATION DETAILScale 1/2'' = 1' - 0'' 3 N.T.S.4 5 CATCH BASIN DETAIL2N.T.S. FIBER ROLL @ INLET 1 N.T.S. FIBER ROLL DETAIL N.T.S. N.T.S.' DRAINAGE CHANNEL DETAIL N.T.S. DISSIPATOR TRENCH11N.T.S. DRAIN LINE @ DRIVEWAY DETAIL JOINT TRENCH DETAIL 13 N.T.S. 9 12 RETAINING WALL DRAINAGE DETAIL Scale 1/2'' = 1' - 0'' PERVIOUS 'XERIBRIX' PAVERS SYSTEM DETAIL Scale 1/2'' = 1' - 0'' TYPICAL BIORETENTION AREA DETAIL18"12" SQ. 18" DIA.18"12" SQ. 1'-0"12"2" min.ROOT ZONE 12"1'-6"10'-0" N.T.S.12'-0"3'-0" 2'-0"4'-0"12"1'-31/2"12"6"4"2"24"12"6"6"2"PEA GRAVEL 6" DIA PVC OUTLET (E) GROUND 3/4" DRAINROCK METAL GRATE RIVER COBBLESTONE DOWNSPOUT WHERE OCCURS (TYP.) SPLASHBLOCK WHERE OCCURS (TYP.) PROPOSED BUILDING 6" DIA PVC OUTLET PEA GRAVEL METAL GRATE 12" SQ. CONC. BOX 12" MIN. CLASS II PERMEABLE ROCK FIBER ROLLS 3/4" X 3/4" WOOD STAKES STAKED AT 1/4 POINTS PROTECTIVE TREE FENCING DRIVEWAY WHERE OCCURS PER PLAN IF WITHIN FIVE FEET OF EDGE OF TREE,THE DRIVEWAY SHALL BE CON- STRUCTED ON TOP OF GRADE TREE DRIPLINE NATURAL GRADE PROTECTIVE TREE FENCING SHALL BE SIX (6) FOOT HIGH CHAIN LINK FENCE MOUNTED ON EIGHT FOOT TALL, TWO (2) INCH DIA. GALV. POSTS, DRIVEN 24 INCHES INTO THE GROUND AND SPACED NO MORE THAN 10 FEET APART 6" DIA. SCHEDULE 40 PVC PERFORATED DRAIN LINE S = 1% MIN. INDICATES MAX. 4" ADDED TOP SOIL TO CREATE GRASSY SWALE 1 1/2" DRAIN ROCK WRAPPED WITH FILTER FABRIC NATIVE SOIL 6" PVC PERFORATED PIPE WITH HOLES UP PLACE PARALLEL TO CONTOUR 4-8" ROCK COVER PERFORATED PIPE WITH LAYER OF ROCK DRAIN PIPE PROVIDE THREADED END CAP AT EACH END NON-WOVEN POLYESTER GEOTEXTILE 6" PVC FLOW CONTROL PIPE TO DISSIPATOR TRENCH PERIMETER BOULDERS - SET INTO SLOPE FOR STABILITTY DROUGHT RESISTANT PLANTING SHRUBS 2" TELEPHONE 30" MIN. U.N.O. PER PG&E REQ. BACKFILL WITH NATIVE MATERIAL PER SOILD REPORT, 95% RELATIVE COMPACTION 4" SAND 1/2" GAS 2" CATV 2" ELECTRIC SAND BASE ROCK- 12" MIN COVER BELOW ROAD SURFACE 2" SAND COVER PERVIOUS 'XERIBRIX' PAVER SYSTEM - 2.38" BY 'XERIPAVE - SUPER PERVIOUS PAVERS' O/ ASTM NO. 8 BEDDING AGGREGATE 1 1/2" -2" O/ ASTM NO. 57 CLEAN CRUSHED AGGREGATE 4" MIN. O/ ASTM NO. 2 OPEN GRADED AGGREGATE BASE MATERIAL 6" MIN. COMPACTED FILL 95% COMPACTION 6" DIA. SCHEDULE 80 PVC SOLID DRAIN LINE S = 1% MIN. (H) # 4 T&B (V) #4 @ 18" O.C. MORTAR SET PAVER PERVIOUS 'XERIBRIX' PAVER SYSTEM - 2.38" BY 'XERIPAVE - SUPER PERVIOUS PAVERS' OVERLAND RELEASE =720.50' NATIVE SOIL - DO NOT COMPACT RIM @ RETENTION POND=721.00'CB4 RIM @ RETENTION POND=721.00' 4" STONE 6" PONDING DEPTH GEOTEXTILE - IMPERMEABLE LINER ADJACENT TO THE RESIDENCE (WITHIN 10') (TYP.) GEOTEXTILE - IMPERMEABLE LINER ADJACENT TO THE RESIDENCE (WITHIN 10') (TYP.) BIO-TREATMENT SOIL (BSM) MIX PER SPECS. 12" MIN OF CLASS II BASE ROCK 18" BIO-TREATMENT SOIL (BSM) MIX PER SPECS. OVERFLOW RISER WITH GRATE CHRISTY V12 12"X12" DRAIN BOX 6" MINIMUM ABOVE LOW POINT OF PLANTING AREA 7 2% MIN SLOPE MIN.3'-0"SLOPE 4% MIN. AT PERVIOUS SURFACES 2% MIN. AT IMPERVIOUS SURFACES 2% MIN SLOPE MIN. BUBBLER INLET BOX MANAGEMENT OF ACTIVITIES IN THE ROOT ZONE Slope Varies Min.4" max.SPACING ALONG SLOPES: 4:1 OR FLATTER = 20'-0" MAX. 4:1 - 2:1 15'-0" MAX. 2:1 OR GREATER = 10'-0" MAX PROVIDE WEEKLY INSPECTION & REINSTALL IF NECESSARY REPLACE EVERY 3 MONTHS. ACCUMULATED SILT SHALL BE REMOVED WHEN IT REACHES A DEPTH OF (6") SIX INCHES PROVIDE 2'-0" MIN. LAP AT FIBER ROLL SPLICES SLOPE BANK VARIES RICE STRAW WATTLES (FIBER ROLL) 8" MIN SET WATTLES INTO SLOPE 2" MIN. / 4" MAX. 3/4" X 3/4" WOOD STAKES (24" MIN. LENGTH) AT 48" O.C. (TYP) 6 8 NOTES: 1. TREE PROTECTIVE FENCING SHALL BE INSPECTED AND APPROVED BY CITY ARBORIST PRIOR TO OBTAINING BUILDING DIVISION PERMITS. 2. NO EXCAVATION SHALL OCCUR UNDER THE TREE CANOPIES FOR INSTALLATION OF UTILITIES OR DRIVEWAY. 3. NO FILL SOIL SHALL BE PLACED ANY CLOSER THAN FIVE FEET OUTSIDE THE EDGE OF THE CANOPY OF ANY TREE ON PROPERTY. 4. UNLESS OTHERWISE APPROVED, ALL CONSTRUCTION ACTIVITIES SHALL BE CONDUCTED OUTSIDE THE DESGINATED FENCED AREA (EVEN AFTER FENCING IS REMOVED). THESE ACTIVITIES INCLUDE, BUT ARE NOT NECESSARILY LIMITED TO, THE FOLLOWING: DEMOLITION, GRADING, TRENCHING, EQUIPMENT CLENAING, STOCKPILING AND DUMPING MATERIALS (INCLUDING SOIL FILL), AND EQUIPMENT/VEHICLE OPERATION AND PARKING. 5. THE DISPOSAL OF HARMFUL PRODUCTS, INCLUDING BUT NOT LIMITED TO CHEMICALS, PAINT RINSE WATER, FUEL, CEMENT WATER RINSE, HERBICIDES, OR OTHER MATERIALS, IS PROHIBITED BENEATH TREE CANOPIES OR ANYWHERE ON SITE THAT ALLOWS DRAINAGE BENEATH TREE CANOPIES. 6. THE FOLLOWING SIGNS WILL BE REQUIRED ON THE TREE PROTECTION FENCES: "TREE PROTECTION FENCE - DO NOT MOVE OR REMOVE WITHOUT PRIOR APPROVAL OF CITY ARBORIST.VARIES2% MIN SLOPE PLAN VIEW SECTION VIEW 1 PROVIDE ADDITIONAL DEPTH TO MAINTAIN THE REQUIRED SEPARATION AND COVER IF GAS FACILITIES CROSS ELECTRIC, TELEPHONE OR CABLE TELEVISION FACILITIES. ENSURE BACKFILL AND COMPACTION MEET ANY APPLICABLE PG&E, FEDERAL, STATE OR LOCAL REQUIREMENTS. 2 3 PROVIDE BACKFILL (SAND OR NATIVE SOIL) CONTAINING NOT MORE THAN OCCASIONAL ROUNDED ROCKS LESS THAN 1/2 INCH IN DIAMETER 4 INCHES ABOVE ALL FACILITIES WITHIN TRENCH AREA. NOTES: TE C G 10 ASTM NO.8 (3/8") CRUSHED STONE ASTM NO.57 (3/4") CRUSHED STONE ASTM NO.2 (2 1/2") CRUSHED STONE RIM=719.50' INV=716.90' BIORETENTION AREA ARE NOT INTENDED TO WORK AS CONSTRUCTION - PHASE BMP'S. PROTECT THE AREA FROM CONSTRUCTION SITE RUNOFF, DIVERT RUNOFF FROM UNSTABILIZED AREAS AWAY FROM COMPLETED BIORETENTION AREAS. MINIMIZE COMPACTION OF EXISTING SOILS IN THE LOCATION OF BIORETENTION AREAS, PROTECT FROM CONSTRUCTION TRAFFIC. TREES AND VEGETATION SHALL NOT BLOCK INFLOW, OR OBSTRUCT UTILITIES. I.P.M. (INTEGRATED PEST MANAGEMENT) PROCEDURES SHALL BE IMPLEMENTED FOR MANTAINENCE CONTINUOUSLY FOR THE LIFE OF THE PROJECT. (NO CHEMICAL PESTICIDES) 2% 2% MIN SLOPE BUBBLER 5 C-7.0 2 % MIN. SLOPE 2 % MIN. SLOPE 18" MIN. BSM18" MIN. BSM"V" DITCH DETAIL 1'-0"1'-0"6"4" PERF. DRAIN PIPE W/ PERF. FACING DOWN PER SOIL'S ENGINEER RECOMMENDATION DRAINROCK FILTER FABRIC CONCRETE RETAINING WALL W/REBAR PER STR. ENGINEERS PLAN (TYP.) STONE VENEER CAP PIECE W/ DRIP EDGE STUCCO SCREED 4" MIN. TO GRADE CONCRETE FOOTING W/REBAR - PER STR. ENGINEERS PLAN (TYP.) 3" PORTLAND CEMENT CONCRETE SWALE SLOPED 1% MIN. GI WEEP SCREED (TYP.): 4" MIN. TO GRADE; 2" MIN. TO PATIO SUBDRAIN OUTFALL PER DETAIL 9/C4 2 :1 MAX FLOW LINE2. RETAIN AND PROTECT NATURAL VEGETATION PRINCIPLES OF EROSION AND SEDIMENT CONTROL SITE THAT WILL BE UNDER CONSTRUCTION DURING THE RAINY SEASON MUST BE WINTERIZED BY OCTOBER 15 4. INFILTRATE RUNOFF FROM INPERVIOUS SURFACES 3. SEED AND MULCH CEARED AREAS 6. DEEP RUNOFF VELOCITIES LOW 7. PROTECT DRAINAGEWAYS AND OUTLETS FROM INCREASED FLOWS 8. TRAP SEDIMENT ON SITE AFTER GRADING IS COMPLETED, SEED AND MULCH THE DENUDED AREAS ACCORDING TO THE PROCEDURES OUTLINED UNDER "REVEGETATION." THE MULCH WILL PROTECT THE SOIL UNTIL THE VEGETATION GETS ESTABLISHED. THE VEGETATION WILL PREVENT EROSION IN FUTURE YEARS. GRASS PROVIDES THE BEST SHORT-TERM PROTECTION. AFTER CONSTRUCTION IS COMPLETED, REPLACE THE GRASS WITH THE DESIRED LONG-TERM VEGETATION AS PART OF THE LANDSCAPING AROUND THE STRUCTURE. ON UNDISTURBED LAND MUCH OF THE RAINWATER SEEPS INTO THE GROUND. ROOFS, PAVED WALKWAYS AND DRIVEWAYS AND PACKED SOIL ARE IMPERVIOUS TO INFILTRATION. RUNOFF FROM THESE SURFACES GREATLY INCREASES EROSION POTENTIAL FOR THIS REASON THE WATER QUALITY CONTROL BOARD REQUIRES THE RUNOFF FROM IMPERVIOUS SURFACES BE INFILTRATED INTO THE GROUND. LOCATE INFILTRATION TRENCHES BELOW ROOF EAVES AND ALONG DRIVEWAYS AND PARKING AREAS. IF A ROOF DRIP LINE OF DRIVEWAY IS ON A STEEP SLOPE, INSTALL A LINED DITCH TO ROUTE THE RUNOFF TO A DRY WELL OR TO AN INFILTRATION TRENCH LOCATED ALONG A SLOPE CONTOUR. INSTALL THESE PERMANENT INFILTRATION SYSTEMS AFTER CONSTRUCTION IS COMPLETED (SEE SAMPLE PERMANENT DRAINAGE PLAN). 5. MINIMIZE LENGTH AND STEEPNESS OF SLOPES LONG OR STEEP EXPOSED SLOPES (OR DRIVEWAYS) HAVE HEIGHT EROSION POTENTIAL. TO SHORTEN RUNOFF PATHWAYS DOWN LONG OR STEEP SLOPES. CONSTRUCT BARRIERS, SUCH AS STRAW BALE OR FIBER ROLL DIKES, ACROSS THE SLOPE. THESE BARRIERS INTERCEPT RUNOFF BEFORE IT CAN REACH AN EROSIVE VELOCITY AND DIVERT IT. DEVELOPMENT CHANGES THE CHARACTERISTICS OF RUNOFF. WHEN LAND IS PAVED OR VEGETATION IS REMOVED AND SOIL IS COMPACTED BY CONSTRUCTION TRAFFIC, THE VOLUME OF RUNOFF INCREASES. RUNOFF FLOWING OVER HARD OR SMOOTH SURFACES SUCH AS PACKED EARTH OR PAVEMENT INCREASES IN VELOCITY, GRADING MAY CAUSE RUNOFF TO CONCENTRATE IN A SINGLE CHANNEL INSTEAD OF BEING DISPERSED OVER A BROAD AREA. THESE CHANGES IN RUNOFF CAN CAUSE CHANNEL EROSION UNLESS PROTECTION MEASURE ARE INSTALLED. COMMON FORMS OF CHANNEL PROTECTION ARE: A. LININGS (GRAVEL, CONCRETE, ASPHALT) B. PIPES OR CULVERTS C. OUTLET PROTECTORS (SUCH AS ROCK APRONS) SEE DETAIL MIN. SEEDING RATE (LBS./1000 SQ.FT. 0.6 0.6 3. WHEN TO PLANT 2. SEED TYPES TO USE 4. STRAW MULCH SEED TYPE 5. OTHER MULCHES 1. REVEGETATION TEMPORARY CONTROL MEASURES GROUP 1 SOD-FORMING WHEATGRASS: 'LUNA' PUBESCENT, 'TOPAR' PUBESCENT, OR 'OAHE' INTERMEDIATE GROUP 2 BUNCHGRASS: POTOMAC ORCHARDGRASS, SHERMAN BIG BLUEGRASS OR 'RESTED WHEATGRASS ALL OF THE ABOVE PLANTS ARE PERENNIAL GRASSES. THE SOIL CONSERVATION SERVICE, U.S. FOREST SERVICE MAY PROVIDE INFORMATION ON THESE AND OTHER SUITABLE PLANT TYPES. 1. TIME GRADING AND CONSTRUCTION TO MINIMIZE SOIL EXPOSURE NATURAL VEGETATION IS THE MOST EFFICIENT FORM OF EROSION CONTROL AND IS ALSO THE MOST DIFFICULT TO RE-ESTABLISH. FOR THIS REASON, ONLY THE AREA REQUIRED FOR CONSTRUCTION SHOULD BE STRIPPED, STAGE GRADING SO THAT ONLY THE PORTION OF THE SITE THAT CAN BE CONSTRUCTED ON ONE YEAR IS CLEARED OF VEGETATION. VEGETATION IS A DESIRABLE FORM OF EROSION CONTROL BECAUSE IT KEEPS SOIL IN PLACE AND MAINTAINS AN ATTRACTIVE, NATURAL-LOOKING LANDSCAPE. VEGETATION REDUCES EROSION BY: A. ABSORBING RAINDROP IMPACT B. REDUCING RUNOFF VELOCITY C. REDUCING RUNOFF VOLUME BY INCREASING INFILTRATION INTO THE SOIL REVEGETATE CLEARED AREAS AS SOON AS POSSIBLE AFTER GRADING. SEE "WHEN TO PLANT." KEEP ALL VEHICLE TRAFFIC OUT OF AREAS THAT HAVE BEEN REVEGETATED. THE ENERGY OF FLOWING WATER DRAMATICALLY INCREASES AS VELOCITY INCREASES. IF VELOCITY DOUBLES, THE EROSIVE ENERGY QUADRUPLES, AND THE WATER CAN MOVE PARTICLES 64 TIMES AS LARGE. VELOCITIES CAN BE KEPT LOW BY: A. KEEPING FLOW VOLUMES LOW (SUCH AS PRESERVING SITE VEGETATION OR BE DIVIDING RUNOFF INTO SEVERAL CHANNELS RATHER THAN ONE) B. CONSTRUCTING FLOW BARRIERS AT FREQUENT INTERVALS LINING CHANNELS WITH ROUGH MATERIAL, SUCH AS ROCKS SOME EROSION DURING CONSTRUCTION IS UNAVOIDABLE. SEDIMENT-LADEN RUNOFF MUST BE DETAINED ON-SITE SO THE THE SOIL PARTICLES CAN SETTLE OUT BEFORE THE RUNOFF REACHES ANY WATERWAY OR SOMEON DES'S PROPERTY. USE ANY OF THE FOLLOWING CONTROL MEASURES TO KEEP SEDIMENT FROM LEAVING THE SITE: THE PRIMARY PURPOSE OF REVEGETATION IS EROSION CONTROL. GRASS PROVIDES THE BEST PROTECTION FOR THE FIRS FEW YEARS. GRASSES GERMINATE AND GROW QUICKLY AND PROVIDE A FAST AND COMPLETE GROUND COVER. TREES AND SHRUBS ARE EFFECTIVE FOR LONG-TERM EROSION CONTROL, BUT GRASSES ARE NEEDED FOR INITIAL SOIL PROTECTION UNTIL THE SLOWER GROWING TRESS AND SHRUBS BECOME WELL ESTABLISHED. DECORATIVE :LANDSCAPING: WITH TREES AND SHRUBS CAN BE DONE LATER CERTAIN CLIMATES AND TERRAINS CAN MAKE IT DIFFICULT FOR PLANTS TO BECOME ESTABLISHED. THE STEEPER THE SLOPE, THE MORE DIFFICULT IT IS. THE GREATEST CHANCE OF SUCCESS WITH REVEGETATION WILL BE IF THE ANGLE OF DISTURBED SLOPES IS KEPT TO A MINIMUM. THE FOLLOWING GRASS SEED MIXES ARE SUITABLE FOR NEARLY ALL SITES IN THE AREA. SELECT ONE SPECIES FROM EACH GRoUP AND COMBINE. THE TIME OF PLANTING DEPENDS ON IRRIGATION. WITH IRRIGATION, ONE MUST CONTINUE TO IRRIGATE UNTIL THE GRASS IS WELL ESTABLISHED. IT IS POSSIBLE TO PLANT SEEDS ANY TIME IN THE TEMPERATE CLIMATE OF THE BAY AREA, BUT FOR BEST RESULTS- (WITHOUT IRRIGATION): A. PLANT SEEDS AS LATE AS POSSIBLE IN THE FALL. OCTOBER AND NOVEMBER ARE GENERALLY GOOD MONTHS TO SEED. SEEDS PLANTED TOO EARLY IN THE FALL MAY GERMINATE WITH FALL RAINS AND THE YOUNG SEEDLINGS CAN THEN BE DILLED BY FROST, OR B. PLANT SEEDS IN MARCH OR APRIL. MAY IS GENERALLY TOO LATE AS THERE PROBABLY WILL NOT BE ENOUGH RAIN TO GERMINATE THE SEED AND ALLOW THE PLANTS TO GROW TO A SIZE THAT CAN SURVIVE THE SUMMER DRY PERIOD. STRAW IS THE BEST MULCH MATERIAL. APPLY ONE BALE OF STRAW PER 1,000 SQ. FT. DISTRIBUTE THE STRAW EVENLY SO THAT IF FORMS A LAYER 1" TO 2" THICK. SOIL SHOULD STILL BE VISIBLE THROUGH THE STRAW MAT. IF YOU APPLY TO MUCH MULCH, IT MAY PRODUCE A MAT TOO DENSE FOR SEEDLINGS TO PENETRATE. ANCHOR THE STRAW BY PUNCHING IT INTO THE SOIL EVERY 1" TO 2" WITH A DULL, ROUND-NOSED SHOVEL (TO AVOID CUTTING THE STRAW) OR BY COVERING IT WITH NETTING (JUTE, PLASTIC, MESH, WOVEN PAPER, OR CHICKEN WIRE). FASTEN THE NETTING TO THE GROUND WITH WIRE STAPLES. BECAUSE THE SOILS IN MANY AREAS ARE QUITE HARD, YOU MAY HAVE TO USE NETTING TO ANCHOR THE STRAW. WOOD FIBERS, WOOD CHIPS AND PINE NEEDLES ARE OTHER REUSABLE MULCH MATERIALS. WOOD FIBER MULCH IS APPLIED HYDRAULICALLY IN A SLURRY THAT ALSO CONTAINS THE SEED AND FERTILIZER. IT IS SUITABLE FOR USE IN STEEP SLOPES OR LARGE AREAS AND MUST BE APPLIED BY CONTRACTOR, (THE APPLICATION RATE OF WOOD FIBER MULCH IS 3,000 LBS./ACRE). WOOD CHIPS AND PINE NEEDLES CAN PROTECT THE SOIL FROM EROSION, BUT THEY ALSO INHIBIT PLANT GROWTH. THEY CAN ONLY BE USED WHERE A GRASS COVER IS NOT DESIRED. APPLY WOOD CHIPS SO THAT SOIL IS COMPLETELY COVERED. APPLY PINE NEEDLES IN A LAYER 2" TO 3" THICK. YOU CAN SAVE THE ORGANIC MATERIALS FROM GRADED AREAS ON THE PROPERTY TO USE AS A MULCH LATER, BUT YOU WILL PROBABLY HAVE TO SUPPLEMENT THEM WITH WOOD CHIPS TO ACHIEVE AN ADEQUATE GROUND COVER. DZ DRAINAGE AND EROSION CONTROL NOTES AND DETAILS AS SHOWN EROSION & SEDIMENT CONTROL MEASURES EROSION CONTROL NOTES GRADING WILL BEGIN ON OR AFTER APRIL 15. FIBER ROLLS WILL BE INSTALLED PER PLAN. SEE DETAILS #2, 3. FIBER ROLLS SHALL BE INSTALLED AT AREA DRAIN AT TWO LOCATIONS. FIBER ROLLS WILL BE INSTALLED IN THE TRENCH TO PREVENT RUNOFF FROM LEAVING THE AREA OF DISTURBANCE. THE PROPOSED DRIVEWAY WILL BE GRAVELED DURING CONSTRUCTION, PROVIDING A BASE FOR PAVING AS A DRIVEWAY. ALL EROSION CONTROL MEASURES / MULCH & SEEDING SHALL BE COMPLETED PRIOR TO OCTOBER 15. AT THAT TIME THE PERMANENT EROSION AND RUNOFF CONTROLS WILL BE INSTALLED AND THE DRIVEWAY WILL BE PAVED. ALL AREAS DISTURBED BY CONSTRUCTION WILL BE SEEDED AND MULCHED. TREE PROTECTION NOTES Fencing Around Trees During Construction: A temporary fence shall be erected around each tree to be retained. The fence should be located at the drip line or a minimum of 5’ from the trunk which ever is greater. The fence should be erected so it will not be easy for construction workers to remove or relocate. This fencing must be erected before any construction equipment enters the site and must not be removed until final landscape grading is complete. Soil compaction and trenching through root zones are the major causes of tree stress in the construction period. It should be explained clearly to all contractors and workers on site that these fences are important and are not to be removed. Trenching of any sort and for any reason must be planned to avoid traversing areas within the tree drip lines. SEE ARBORIST REPORT BY CTA VERSION: 1/8/2016 FOR MORE INFO. METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : C-7.1 Coker Residence PC2 6-30-17.pln7/5/20174:02 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 CONSTRUCTION DETAILS N/A AS NOTED METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : C-8.0 Coker Residence PC2 6-30-17.pln7/5/20174:03 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 R 42'R 42'R 30' R 30' INDICATES 42' MINIMUM OUTSIDE TURNING RADIUS PER FIRE DEPARTMENT SCC -STANDARD DETAILS & SPECIFICATIONS SPEC NO A-1 (06/01/09) 5. EXISTING GATE TO REMAIN LOT 5 EXIST .10 ' P .S .E . EX I S T . 1 0 ' P.S.E. EX. 15' PRIVATE DRAINAGE EASEMENT EXIST. STORM DRAIN, PRIVATE SANITARY SEWER & EMERGENCY ACCESS EASEMENT PREVIOUSLY PROPOSED 15' E.V.A.E. LEGEND PROPOSED 20' E.V.A.E. S.D.E. & P.S.S.E. LOT 6 NSTA DW1 0+00'ELEV 716.64'STA DW2 0 + 31.70'ELEV.= 718.00'STA DW3 0+67.70'ELEV.= 718.00'STA DW5 0+101.06'ELEV.= 716.39'STA DW6 0+154.13'ELEV.=716.46'STA DW7 0+169.22'ELEV. = 717.00'STA DW8 +180.92'ELEV. = 718.00'STA DW9 0+193.00'ELEV. = 719.00'STA DW10 0+208.92'EP = 719.70'STA DW4 0+86.19'ELEV.=717.00'EP 0+230.41'ELEV. = 719.27'PROFILE OF PROPOSED EMERGENCY VEHICLE ACCESS ROAD EXISTING GRADE 4'-0" MAX. GRADING CUT PER HDSG TABLE 1 698 700 702 704 706 708 710 712 714 716 718 720 722 PL 698 700 702 704 706 708 710 712 714 716 718 720 722 SSMH (E) RIM 721.68 (P) RIM 718.03 INV 697.36 (THRU) SSMH RIM 718.18 INV 711.00 6" (IN-SW) INV 698.18 6" (IN-N) INV 697.82 6" (OUT-NW) INV 698.38 6" (IN-E) INV 698.02 6" (IN-S) SSMH INV 695.44 8" (THRU) SDMH (E) RIM 720.75 (P) RIM 716.33 INV 710.95 15" (IN-E) INV 710.75 15" (OUT-W) SDMH INV 709.87 15" (IN-E) INV 709.82 15" (OUT-NW) SDMH INV 712.05 15" (IN-E) INV 711.87 15" (OUT-W) FOSTER ROAD (E) RIM 720.13 (P) RIM 719.49 (E) RIM 720.33 (P) RIM 719.20 (E) RIM 721.79 (P) RIM 718.16 EASEMENT DISPOSITION PLAN DZ 1" = 20'-0" SCALE : 1" = 10'-0" PROPOSED PROFILE AT EMERGENCY VEHICLE ACCESS ROAD METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-1.0 Coker Residence PC2 6-30-17.pln7/5/20174:03 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 2 3 4 1 7 6 3 A1.1 1 A1.1 225'-0"20'-0"30'-0"22'-6"30'-4"36' -41/2"40'-1"15'-0"25'-9"103'-71/2"10'-0"R 30' R 42'R 4 2 'R 30' S1 A1.2 S2 A1.2 S3 A1.2 S4 A1.2 INDICATES 42' MINIMUM OUTSIDE TURNING RADIUS PER FIRE DEPARTMENT SCC -STANDARD DETAILS & SPECIFICATIONS SPEC NO A-1 (06/01/09) 5. INDICATES EXISTING 6" HDPE SEWER LINE AT FOSTER ROAD (N) ADDRESS SIGNAGE/ IDENTIFICATION AT EXISTING STONE COLUMN TO REMAIN (TYP.) U.N.O. INDICATES PROPOSED RESIDENCE, TYP. INDICATES PROPOSED DRIVEWAY W/ PERVIOUS PAVERS INDICATES EXISTING WATER METER LOCATION TO REMAIN (TYP.) U.N.O. INDICATES CURB AND GUTTER INDICATES JOINT TRENCH FOR NEW UNDERGROUND SERVICE FOR (N) GAS, (N) ELECTRIC, PHONE AND CABLE SERVICE CONNECT NEW 6" PVC SDR 26 SANITARY SEWER LINE W/TOWN'S SEWER LINE AT FOSTER ROAD, MIN. 10' AWAY FROM WATER LINE EXISTING FIRE HYDRANT TO REMAIN (TYP.) U.N.O. -SEE LOCATION ON SHEET T-1 -PARTIAL TOPOGRAPHICAL SURVEY INDICATES EXISTING TREE TO REMAIN, TYP. INDICATES LRDA (SLOPE UNDER 30 %) -TYP. INDICATES NEW CURB CUT-TYP. INDICATES MIN. 20' WIDE EASEMENT FOR EMERGENCY VEHICLE, SDE & PSSE INDICATES MAX. 6'-0" HIGH FENCE - TYP. INDICATES MAX. 6'-0" HIGH FENCE INDICATES MAX. 6'-0" TALL WOOD FENCE WITH TOP AND BOTTOM RAIL AND 2 x 4 BROWN PVC VINYL COATED WELDED WIRE FENCING INDICATES GATE WITH AN APPROVED FIRE DEPARTMENT LOCK BOX INDICATES MAX. 6'-0" HIGH CHAIN LINK FENCE VINYL COATED DARK BROWN COLOR W/ STEEL POSTS - TYP. INDICATES 12' WIDE PROPOSED EMERGENCY VEHICLE ACCESS ROAD WITH Grasspave2 INDICATES LRDA (SLOPE UNDER 30 %) -TYP. INDICATES (N) GAS METER LOCATION F O S T E R R O AD UP UP COURTYARD PLANTER PLANTER 3 - GARAGE COVERED VERANDA POOL COVERED VERANDA PLANTER PLANTER PLANTER PLANTER 2 % SLOPE ACCESSORY BUILDING PROPOSED SINGLE STORY RESIDENCE REAR SETBACK LINEFRONT SETBACK LINESIDE SETBA C K LINE POOL EQUIP.740735730725725720730 735730725715710715710N 71°56'26" W178.26'R=86.93'D=51°07'18"L=77.56'R =142 .91 ' Δ=77°24'59"L=193.10' (Δ=77°25'09") R=106.94' Δ=9°56 '53" L =18.57' R =162 .91 ' Δ=77°36'48" L= 22 0 .68 ' N 00°09'11" E 304.71' S 4 7 °3 5 '3 9 " W 3 5 .3 1 ' L = 3 6 .8 9 L=52.61 SPA 11" OAK 18" OAK 21" OAK 20" BAY 15" BLUE OAK 26" BLUE OAK SITE PLAN LEGEND PROPERTY LINE SETBACK LINE (E) GRADE MINOR CONTOUR LINE (E) GRADE MAJOR CONTOUR LINE PROPOSED GRADE CONTOUR LINE TREE PROTECTION FENCING EXISTING TREE TO REMAIN PROPOSED RESIDENCE PROPOSED CELLAR PERVIOUS PAVERS-'XERIBRIX' BY 'XERIPAVE SUPER PERVIOUS PAVERS' -HERRINGBONE PATTERN, DUPONT COLOR AT DRIVEWAY PROPOSED HARDSCAPE DECOMPOSITE GRANITE Grasspave2 @ EMERGENCY VEHICLE ACCESS ROAD EXISTING EMERGENCY VEHICLE ACCESS ROAD 20" BAY LOWER TERRACE E 4" HDPE6" HDPE 8" HDPE~~6"6"15" HDPESD15" HDPESDSD15" HDPE8" HDPE WV WM RIM 723.09 SSCO 723.4 ELEC. MARKER 723.80TB723.77FOB72 3 .47CA T V FOFOSSMH RIM 724.38 INV 714.86 (THRU) NEW FENCE NEW GAS LINE NEW WATER LINE NEW ELECTRIC LINE NEW JOINT TRENCH NEW SANITARY SEWER LINE 20 '-0 " 12 '-0 " EXISTING FENCE EXISTING GAS LINE EXISTING WATER LINE EXISTING ELECTRIC LINE EXISTING JOINT TRENCH EXISTING SANITARY SEWER LINE NOTE:ALL EXISTING TREES TO REMAIN AND TO BE PROTECTED DURING CONSTRUCTION -TYP. FND. MON723 F.F. = 722'-0" F.S. = 722'-0" F.S. = 722'-0"F.S. = 722'-0" CELLAR F.S. = 710'-9" F.S . = 720'-8" 718 717 718720PRIVATE STORMDRAINAGE EASEMENT12'-0"PLANTER720 G CO 4" HDPE GRAPHIC SCALE: (IN FEET) 10 0 5 10 20 30 717722 EXISTING 10' P.S.E. EASEMENT 720721719719 INDICATES (N) ELEC. METER LOCATION NPROPOSED SITE PLAN DZ 1" = 10'-0" SITE LEGEND SITE PLAN SCALE: 1" = 10'-0" METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-1.1 Coker Residence PC2 6-30-17.pln7/5/20174:03 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 Scale 3/8'' = 1' - 0'' ENTRY GATE DETAIL2Scale 3/8'' = 1' - 0'' ADDRESS COLUMN DETAIL1 3 Scale 3/8'' = 1' - 0'' 2'-6"2'-6"2" MIN.3'-6"2'-4" +'- 2" MIN.3" TYP.3" TYP. 3'-0" 12'-9"6'-11"6'-0"2'-0"2'-0"4"6'-0"1'-8" +/-2'-0"6'-0"6'-0"2'-0"1'-2"1'-2" 6'-0" 1'-2"6'-0"6'-6"2'-0" 2% CROSS SLOPE PRECAST CONCRETE CAP AUTOMATIC WROUGHT IRON GATE TURF O/ 1" 'GRASSPAVE2' SYSTEM O/ 6" COMPACT SANDY GRAVEL O/ NAT. GRADE COMPACTED TO 95% COMPACTION (TYP.) 2x2 P.T.D.F. EACH SIDE OF MESH 4x6 P.T.D.F. EA. SIDE OF MESH 2x4 P.T.D.F. FLAT ON TOP OF POSTS 4x6 P.T.D.F. POST @ 6'-0" O.C. INDICATES GRADE ELEVATION 14" DIA. CONCRETE PIER - SLOPED AT TOP 4x6 P.T.D.F. EA. SIDE OF MESH 60" TALL -2 x 4 BROWN PVC VINYL COATED WELDED WIRE FENCING 14" DIA. CONCRETE PIER - SLOPED AT TOP 2x4 P.T.D.F. FLAT ON TOP OF POSTS 4x6 P.T.D.F. EA. SIDE OF MESH 4x6 P.T.D.F. POST @ 6'-0" O.C. 2x2 P.T.D.F. EACH SIDE OF MESH 60" TALL -2 x 4 BROWN PVC VINYL COATED WELDED WIRE FENCING 60" TALL -2 x 4 BROWN PVC VINYL COATED WELDED WIRE FENCING ALIGN 20102 USPS APPROVED MAILBOX (TYP. ADDRESS SIGNAGE PLAQUE PER CRC SEC 319.1 & CBC SEC 505.1 STONE VENEER TO MATCH RESIDENCE (TYP.) RECESSED 'IN GROUND LIGHT FIXTURE, TYP. PRECAST CONC. CAP MATCH RESIDENCE (TYP.) 20 GA. STEEL MAILBOX 'CAP' TO MATCH CHIMNEY CAP DESIGN (41" - 45")SIDE VIEW 1" RECESS AT, FRONT, SIDE, AND REAR FACES FRONT VIEW EXISTING SLOPE (12'-0" MIN. CLR.)PER USPSREQUIREMENTSSECTIONELEVATION PLAN VIEW OPEN FENCE - DETAIL MAX. 2:1 SLOPE MAX.MAX.@ GATE8'-0" MAX @ GATE2 3 4 1 5 8 7 6 INDICATES 12' WIDE PROPOSED EMERGENCY VEHICLE ACCESS ROAD WITH Grasspave2 PROPOSED DRIVEWAYINDICATES AREA WITHIN LRDA LIMIT LINE (SLOPE UNDER 30 %) PROPOSED RESIDENCE INDICATES AREA OUTSIDE LRDA LIMIT LINE (SLOPE 30 % OR MORE)PROPOSED HARDSCAPE 12' WIDE PROPOSED EMERGENCY VEHICLE ACCESS ROAD WITH GRASS PAVERS UP UP NSITE DIAGRAMS D.Z. SITE CONSTRAINTS DIAGRAM SITE DETAILS 1. SITE CONSTRAINTS DIAGRAM AS NOTED METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-1.2 Coker Residence PC2 6-30-17.pln7/5/20174:03 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-173'-0"4'-0"12'-9"PROPOSED GRADE EXISTING GRADE PROPOSED MAX. 6' TALL FENCE PLANTER 2' WIDE DRAINAGE CHANNEL SEE DET 10/ C-7.0 2' CONCRETE 'V' DITCH 6" DEEP SEE DET 13 / C-7.0 CELLAR VERANDA DINING ROOMMAX. 2:1SLOPE LIGHTWELLSETBACK LINEPROPERTY LINE720 722 724 726 728 730 732 734 736 718 716 714 712 710 720 722 724 726 728 730 732 734 736 718 716 714 712 710maxcut 13'-6"3'-11"EXISTING GRADE PROPOSED GRADE INDICATES 12' WIDE PROPOSED EMERGENCY VEHICLE ACCESS ROAD INDICATES 20 FT WIDE E.V.A.E. INDICATES 13.5 FT VERTICAL CLEARANCE FOR EMERGENCY VEHICLES PROPOSED MAX. 6' TALL FENCE MASTER BEDROOM 4 %SLOPE MAX. CUT 20' 12' 720 722 724 726 728 730 732 734 736 718 716 714 3'-41/2"INDICATES 12' WIDE PROPOSED EMERGENCY VEHICLE ACCESS ROAD PROPOSED GRADE EXISTING GRADE TO REMAIN EXISTING GRADE INDICATES 20 FT WIDE E.V.A.E. PROPOSED MAX. 6' TALL FENCE ACCESSORY BUILDING 2.5 %SLOPE MAX. CUT720 722 724 726 728 730 732 734 736 718 716 714 3'-10" EXISTING GRADE PROPOSED GRADE INDICATES 12' WIDE PROPOSED EMERGENCY VEHICLE ACCESS ROAD INDICATES 20 FT WIDE E.V.A.E. 721.75'722.00'720.75' 720.67'720.50'PROPOSED MAX. 6' TALL FENCE (P) TC=716.33' POOL LAWN GREAT ROOM COVERED VERANDA LOWER TERRACE CELLAR MAX. CUT 20' 12' 720 722 724 726 728 730 732 734 736 718 716 714 720 722 724 726 728 730 732 734 736 718 716 714 712712 710710 708708 706706 SITE DIAGRAMS D.Z. SITE CONSTRAINTS DIAGRAM SITE DETAILS SITE SECTIONS SECTION S1 SECTION S2 SECTION S4 SCALE : 3/16" = 1'-0"SCALE : 3/16" = 1'-0" SECTION S3 SCALE : 3/16" = 1'-0" 3/16" = 1'-0" SCALE : 3/16" = 1'-0" METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-2.0 Coker Residence PC2 6-30-17.pln7/5/20174:03 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 142'-51/2" 34'-1/2"44'-7"57'-10"6'-0" 13'-1/2"21'-0"16'-11/2"12'-2"16'-31/2"9'-91/2"12'-11/2"10'-0"3'-111/2"18'-0"3'-111/2"6'-0"22'-91/2"6'-0"29'-51/2"30'-11"21'-0"7'-1"117'-21/2"4'-111/2"28'-51/2"23'-5"26'-0"34'-6"117'-4"142'-51/2" 21'-91/2"21'-3"10'-111/2"20'-7"19'-5"42'-5"6'-0"22'-4"17'-51/2"12'-51/2"29'-41/2"1'-61/2"21'-9"8'-81/2"8'-0"8'-91/2"25'-0" 14'-9"4'-0"14'-9" 12'-11/2"21'-0"21'-0"21'-0"33'-11/2" A A-5.0 A A-5.0 B A-5.0 B A-5.0 INDICATES 20'-0" x 20'-0" CLEAR - REQUIRED 2 CARS PARKING DIMENSIONS INDICATES 11'-0" x 20'-0" CLEAR - REQUIRED 1 CAR PARKING DIMENSIONS 3 - GARAGE HER CLOSET HIS CLOSET MASTER BEDROOM SUITE MASTER BATH LINEN & STORAGE ELEV. FOYER DINING ROOM LIBRARY PORCH SEE - THRU FIREPLACE WASHER &DRYER MUD ROOM KITCHEN GREAT ROOM FIREPLACE BALCONY COURTYARD COVERED VERANDA TOILET LINEN 1/2 BATH PANTRY BATH 3 BEDROOM 2 VANITY BATH 2 SO CM REF FRZ VERANDA WINEPLANTER PLANTER CLO. 14'-0" x 14'-0" BEDROOM 3 14'-0" x 14'-0" BEDROOM 4 12'-0" x 12'-0" NOOK 12'-9" x 12'-9" 13'-3" x 21'-3"23'-6" x 22'-6"23'-0" x 22'-0" 14'-6" x 18'-0" 13'-6" x 18'-4" 18'-3" x 25'-0" 21-0" x 20'-6" 14'-0" x 17'-0" 8'-0" x 12'-4" 10'-0" x 12'-0" VESTIBULE PORCH 7'-0" x 10'-8" SHOWER DN WINEDN BATH 4 STORAGE PLANTER HILLSIDE GARDEN AREA N24'-11" 23'-2" 1'-101/2"21'-21/2"1'-101/2"10'-31/2"10'-31/2"22'-31/2"11'-61/2"10'-9"BEDROOM BATH COVERED VERANDA 10'-0" x 12'-0" C A-5.0 C A-5.0 MAIN FLOOR PLAN TS 1/8" = 1'-0" PROPOSED MAIN FLOOR PLAN ACCESSORY BUILDING FLOOR PLAN METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-2.1 Coker Residence PC2 6-30-17.pln7/5/20174:03 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 142'-51/2" 21'-91/2"47'-21/2"22'-41/2"51'-1" 142'-51/2" 21'-91/2"6'-111/2"49'-101/2"12'-9"51'-1"117'-21/2"28'-4"29'-11"30'-11"28'-1"117'-4"6'-51/2"52'-41/2"30'-51/2"28'-1"GOLF SIMULATION RECREATION ROOM COVERED VERANDAHILLSIDE GARDEN AREA UP ELEV. UP GYM MECH. ROOM WET BAR SPORTS MEMORABILIA SPORTS MEMORABILIA SPORTS MEMORABILIA MECH. ROOM BATH 5 10 FT. MONITOR SPORTS MEMORABILIA21'-0" x 26'-9"20'-0" x 26'-9" 30'-0" x 29'-0" 9'-6" x 16'-8" SPORTS MEMORABILIA PLANTER MECH. ROOM SUMP PUMP A A-5.0 A A-5.0 B A-5.0 B A-5.0 NTS 1/8" = 1'-0" PROPOSED CELLAR FLOOR PLAN CELLAR FLOOR PLAN METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-3.0 Coker Residence PC2 6-30-17.pln7/5/20174:03 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17A A-5.0 A A-5.0 B A-5.0 B A-5.0 C A-5.0 C A-5.0 1'-91/2"1'-91/2"1'-91/2"18"18"18"18" 18" INDICATES BUILDING LINE -TYP. INDICATES ROOF SLOPE -TYP. INDICATES SOFFIT AT EAVE -TYP. INDICATES DOWNSPOUT -TYP. INDICATES ROOF LINE -TYP. INDICATES ROOF GUTTER -TYP. INDICATES CLASS 'A' TERRA COTTA CLAY TILE ROOFING -TYP. INDICATES BUILDING LINE -TYP. INDICATES ROOF SLOPE -TYP. INDICATES SOFFIT AT EAVE -TYP. INDICATES DOWNSPOUT -TYP . INDICATES ROOF GUTTER -TYP. INDICATES ROOF LINE -TYP. INDICATES CLASS 'A' TERRA COTTA CLAY TILE ROOFING -TYP. INDICATES BUILDING LINE AT CELLAR -TYP. H.P.=736.16' H.P.=739.81' H.P.=738.62' H.P.=738.84' H.P.=738.61' RIDGE HIPVALLEYRIDGERIDGE RIDGERIDGE RIDGE RIDGE RIDGERIDGERIDGERIDGERIDGERIDGERIDGERIDGERIDGERIDGE HIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPHIPVALLEYVALLEYVALLEYVALLEYVALLEYVALLEYVALLEYVALLEYVALLEYVALLEYVALLEY VALLE Y VALLEYVAL L E Y VALLE Y VAL L E YVALLEYVALLEYVALLEYVALLEYV A L L E Y 4:12 2'-4" :12 2'-4" :12 4:124:124:12 4:12 4:124:12 4:121'-10" :12 4:124:124:12 4:124:124:124:124:124:123.5:124:124:124:12 4:124:124:124:12 4:124:124:124:123:124:12 4:12 4:124:124:124:124:124:124:12 4:12 4:124:12 4:124:124:124:12 4:124:12DS DS DS DS DS DSDS DS DS DS DS DS DS DS DS DS DS TYP. U.N.O. TYP. U.N.O. TYP. U.N.O. DSDS DZ PROPOSED ROOF PLAN DZ 1/8" = 1'-0" METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-4.0 Coker Residence PC2 6-30-17.pln7/5/20174:03 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-1718'-0" MAX. PROPOSED HIGHT = 739.81' EXISTING GRADE & PROPOSED GRADE = 721.83' INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES EXISTING GRADE AT THE FACE OF THE WALL INDICATES 18' VERTICAL DISTANCE FROM THE EXISTING GRADE AT WALL FACE ABOVE CELLAR INDICATES 18' VERTICAL DISTANCE FROM THE PROPOSED GRADE AT WALL FACE INDICATES PROPOSED COURTYARD WALL SHOWN DASHED INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES EXISTING GRADE AT THE FACE OF THE WALL INDICATES 18' VERTICAL DISTANCE FROM THE PROPOSED GRADE AT WALL FACE GARAGE F.SLAB = 721.98' F.G. = 721.33' BASEMENT F. SLAB = 710.75' ( -11'-3") F.F = 722.00' (± 0.00') 1 4 6 8 2 5 9 10 11 12 3 4 7 7 7 7 9 9 11 10 T.P.= 731.83' (+ 9'-10") T.P.= 734.00' (+ 12'-0") T.P.= 732.50' (+ 10'-6") T.P.= 737.50' (+ 15'-6") T.P.= 734.00' (+ 12'-0") H.P. = 738.85' H.P. = 737.52' H.P. = 736.58' F.F = 722.00' (± 0.00') T.P.= 734.00' (+ 12'-0") T.P.= 732.50' (+ 10'-0") INDICATES 18' VERTICAL DISTANCE FROM THE EXISTING GRADE AT RIDGE LOCATION ABOVE CELLAR MAX. PROPOSED HIGHT = 739.81' INDICATES 18' VERTICAL DISTANCE FROM THE EXISTING GRADE AT RIDGE LOCATION INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES EXISTING GRADE AT THE FACE OF THE WALL INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES EXISTING GRADE AT THE FACE OF THE WALL T.P.= 734.50' (+ 12'-6") T.P.= 732.50' (+ 10'-6") F.F = 722.00' (± 0.00') BASEMENT F. SLAB = 710.75' ( -11'-3") F.G. = 721.33'F.G. = 721.33' F.G. = 721.00'F.G. = 717.12' H.P. = 734.02' 1 4 6 8 2 5 10 3 4 7 7 7 7 3 5 7 8 8 H.P. = 738.85' H.P. = 738.61' 1 2 3 4 5 6 7 8 9 10 11 12 13 EXERIOR FINISHES ROOFING: EAVES: SOFFIT COLOR INTEGRAL STUCCO PLASTER FINISH W/ 'MILLBROOK STONE' CUSTOM CAST STONE WALL FINISH: COLOR INTEGRAL PLASTER FINISH HARD TROWELED SMOOTH FINISH COAT TO MATCH KELLY MOORE KM5716-3 'RODEO ROUNDUP'-LRV 30 EXTERIOR TRIM ELEMENTS, CAST STONE TRIM COLUMNS: 'MILLBROOK STONE' CUSTOM CAST STONE EXTERIOR DOORS CLAD WOOD WINDOWS - BRONZE COLOR & WINDOWS: CLAD WOOD DOORS - BRONZE COLOR CAST STONE DOOR SURROUND & SILLS GUARDRAIL, GATE: WROUGHT IRON RAILING BRONZE PAINTED W.I. RAILING & GUARDRAILS CHIMNEY CAP: WALL FINISH: FIELDSTONE PATTERN VENEER 'BUECHEL FIELDSTONE' - OVERGROUT FINISH GUTTERS & DOWNSPOUTS: HALF ROUND GUTTERS & ROUND DOWNSPOUTS 5.5" HALF-ROUND - COPPER GARAGE DOOR: 'CARRIAGE' STYLE DOOR STAINED WOOD EXTERIOR DOORS: WROUGHT IRON DOORS - BRONZE COLOR CAST STONE DOOR SURROUND & SILLS WALKWAYS & PATIOS: LIMESTONE - ANTIQUE FINISH DRIVEWAY: PERVIOUS PAVERS- 'XERIBRIX' BY 'XERIPAVE SUPER PERVIOUS PAVERS' -HERRINGBONE PATTERN, DUPONT COLOR 'CAP & PAN' TILE ROOFING REDLAND CLAYTILE-TWO -PIECE MISSION 2000 SERIES- OLD SEDONA BLEND -AVERAGE LRV 15.5 SW 6062 LRV 7RUGGED BROWN SW 6076 LRV 5RUGGED BROWN CHIMNEY CAP ARCHITECTURAL COPPER W/ SPARK ARRESTOR -AVERAGE LRV 6 SW 6109 LRV 24HOPSACK SW 6124 LRV 22CARDBOARD -AVERAGE LRV 23 PROPOSED FRONT ELEVATION: EAST SCALE : 3/16" = 1'-0" DZ 3/16" = 1'-0" PROPOSED RESIDENCE EXTERIOR ELEVATIONS FRONT ELEVATION, E SIDE ELEVATION, N SCALE : 3/16" = 1'-0" PROPOSED RIGHT SIDE ELEVATION: NORTH METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-4.1 Coker Residence PC2 6-30-17.pln7/5/20174:04 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 GARAGE F.SLAB = 722.25' T.P.= 734.50' (+ 12'-6") T.P.= 731.83' (+ 9'-10") T.P.= 732.50' (+ 10'-6") T.P.= 734.00' (+ 12'-0") F.F = 722.00' (± 0.00') F.F = 722.00' (± 0.00') INDICATES EXISTING GRADE AT THE FACE OF THE WALL INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES 18' VERTICAL DISTANCE FROM THE EXISTING GRADE AT WALL FACE ABOVE CELLAR F.G. = 721.33'F.G. = 721.33' INDICATES 18' VERTICAL DISTANCE FROM THE PROPOSED GRADE AT WALL FACE MAX. PROPOSED HIGHT = 739.81' H.P. = 736.58' H.P. = 737.52'H.P. = 738.85' 10 7 7 7 7 4 3 5 2 8 6 4 1 1 5 5 8 8 BASEMENT F. SLAB = 710.75' ( -11'-3")4'-0"BASEMENT F. SLAB = 710.75' ( -11'-3") 4 8 2 5 10 3 7 7 3 5 7 8 INDICATES 18' VERTICAL DISTANCE FROM THE PROPOSED GRADE AT WALL FACE F.F = 722.00' (± 0.00') T.P.= 732.50' (+ 10'-6") T.P.= 734.50' (+ 12'-6") INDICATES 18' VERTICAL DISTANCE FROM THE EXISTING GRADE AT RIDGE LOCATION MAX. PROPOSED HIGHT = 739.81' INDICATES 18' VERTICAL DISTANCE FROM THE EXISTING GRADE AT RIDGE LOCATION ABOVE CELLAR INDICATES EXISTING GRADE AT THE FACE OF THE WALL INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES EXISTING GRADE AT THE FACE OF THE WALL INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL GARAGE F.SLAB = 722.00' T.P.= 731.83' (+ 9'-10") T.P.= 734.00' (+ 12'-0") GARAGE F.SLAB = 721.25' F.G. = 721.33'F.G. = 721.00'TOP OF RETAINING WALL = 719.00' 7 7 8 10 5 1 1 4 PROPOSED GRADE @ 'V' DITCH = 718.00' F.G. = 722.50' INDICATES RETAINING WALL BEHINDMAX. CUT1 2 3 4 5 6 7 8 9 10 11 12 13 EXERIOR FINISHES ROOFING: EAVES: SOFFIT COLOR INTEGRAL STUCCO PLASTER FINISH W/ 'MILLBROOK STONE' CUSTOM CAST STONE WALL FINISH: COLOR INTEGRAL PLASTER FINISH HARD TROWELED SMOOTH FINISH COAT TO MATCH KELLY MOORE KM5716-3 'RODEO ROUNDUP'-LRV 30 EXTERIOR TRIM ELEMENTS, CAST STONE TRIM COLUMNS: 'MILLBROOK STONE' CUSTOM CAST STONE EXTERIOR DOORS CLAD WOOD WINDOWS - BRONZE COLOR & WINDOWS: CLAD WOOD DOORS - BRONZE COLOR CAST STONE DOOR SURROUND & SILLS GUARDRAIL, GATE: WROUGHT IRON RAILING BRONZE PAINTED W.I. RAILING & GUARDRAILS CHIMNEY CAP: WALL FINISH: FIELDSTONE PATTERN VENEER 'BUECHEL FIELDSTONE' - OVERGROUT FINISH GUTTERS & DOWNSPOUTS: HALF ROUND GUTTERS & ROUND DOWNSPOUTS 5.5" HALF-ROUND - COPPER GARAGE DOOR: 'CARRIAGE' STYLE DOOR STAINED WOOD EXTERIOR DOORS: WROUGHT IRON DOORS - BRONZE COLOR CAST STONE DOOR SURROUND & SILLS WALKWAYS & PATIOS: LIMESTONE - ANTIQUE FINISH DRIVEWAY: PERVIOUS PAVERS- 'XERIBRIX' BY 'XERIPAVE SUPER PERVIOUS PAVERS' -HERRINGBONE PATTERN, DUPONT COLOR 'CAP & PAN' TILE ROOFING REDLAND CLAYTILE-TWO -PIECE MISSION 2000 SERIES- OLD SEDONA BLEND -AVERAGE LRV 15.5 SW 6062 LRV 7RUGGED BROWN SW 6076 LRV 5RUGGED BROWN CHIMNEY CAP ARCHITECTURAL COPPER W/ SPARK ARRESTOR -AVERAGE LRV 6 SW 6109 LRV 24HOPSACK SW 6124 LRV 22CARDBOARD -AVERAGE LRV 23 PROPOSED REAR ELEVATION: WEST SCALE : 3/16" = 1'-0" DZ 3/16" = 1'-0" PROPOSED RESIDENCE EXTERIOR ELEVATIONS FRONT ELEVATION, S SIDE ELEVATION, W SCALE : 3/16" = 1'-0" PROPOSED LEFT SIDE ELEVATION: SOUTH METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-4.2 Coker Residence PC2 6-30-17.pln7/5/20174:04 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-17 1 2 3 4 5 6 7 8 9 10 11 12 13 EXERIOR FINISHES ROOFING: EAVES: SOFFIT COLOR INTEGRAL STUCCO PLASTER FINISH W/ 'MILLBROOK STONE' CUSTOM CAST STONE WALL FINISH: COLOR INTEGRAL PLASTER FINISH HARD TROWELED SMOOTH FINISH COAT TO MATCH KELLY MOORE KM5716-3 'RODEO ROUNDUP'-LRV 30 EXTERIOR TRIM ELEMENTS, CAST STONE TRIM COLUMNS: 'MILLBROOK STONE' CUSTOM CAST STONE EXTERIOR DOORS CLAD WOOD WINDOWS - BRONZE COLOR & WINDOWS: CLAD WOOD DOORS - BRONZE COLOR CAST STONE DOOR SURROUND & SILLS GUARDRAIL, GATE: WROUGHT IRON RAILING BRONZE PAINTED W.I. RAILING & GUARDRAILS CHIMNEY CAP: WALL FINISH: FIELDSTONE PATTERN VENEER 'BUECHEL FIELDSTONE' - OVERGROUT FINISH GUTTERS & DOWNSPOUTS: HALF ROUND GUTTERS & ROUND DOWNSPOUTS 5.5" HALF-ROUND - COPPER GARAGE DOOR: 'CARRIAGE' STYLE DOOR STAINED WOOD EXTERIOR DOORS: WROUGHT IRON DOORS - BRONZE COLOR CAST STONE DOOR SURROUND & SILLS WALKWAYS & PATIOS: LIMESTONE - ANTIQUE FINISH DRIVEWAY: PERVIOUS PAVERS- 'XERIBRIX' BY 'XERIPAVE SUPER PERVIOUS PAVERS' -HERRINGBONE PATTERN, DUPONT COLOR 'CAP & PAN' TILE ROOFING REDLAND CLAYTILE-TWO -PIECE MISSION 2000 SERIES- OLD SEDONA BLEND -AVERAGE LRV 15.5 SW 6062 LRV 7RUGGED BROWN SW 6076 LRV 5RUGGED BROWN CHIMNEY CAP ARCHITECTURAL COPPER W/ SPARK ARRESTOR -AVERAGE LRV 6 SW 6109 LRV 24HOPSACK SW 6124 LRV 22CARDBOARD -AVERAGE LRV 2315'-0"INDICATES 15' VERTICAL DISTANCE FROM THE PROPOSED GRADE AT WALL FACE INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES EXISTING GRADE AT THE FACE OF THE WALL F.G. = 720.00' 1 4 8 5 3 7 H.P. = 734.91' T.P.= 730.67' (+ 10'-0") F.F = 720.67' (± 0.00') 7 15'-0"F.F = 720.67' (± 0.00') T.P.= 730.67' (+ 10'-0") 7 INDICATES EXISTING AND PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES 15' VERTICAL DISTANCE FROM THE EXISTING AND PROPOSED GRADE AT WALL FACE F.G. = 720.00' H.P. = 734.91' 1 4 8 5 3 7 4 15'-0"INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES EXISTING GRADE AT THE FACE OF THE WALL H.P. = 734.91' 7 3 5 8 4 1 F.G. = 720.00' INDICATES 15' VERTICAL DISTANCE FROM THE PROPOSED GRADE AT WALL FACE T.P.= 730.67' (+ 10'-0") F.F = 720.67' (± 0.00') 715'-0"INDICATES 15' VERTICAL DISTANCE FROM THE PROPOSED GRADE AT WALL FACE INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES EXISTING GRADE AT THE FACE OF THE WALL F.G. = 720.00' 1 4 5 3 7 H.P. = 734.91' T.P.= 730.67' (+ 10'-0") F.F = 720.67' (± 0.00') 7 8 PROPOSED FRONT ELEVATION: EAST SCALE : 3/16" = 1'-0" DZ 3/16" = 1'-0" PROPOSED ACCESSORY BUILDING EXTERIOR ELEVATIONS FRONT ELEVATION, E SIDE ELEVATION, N REAR ELEVATION, W SIDE ELEVATION, S SCALE : 3/16" = 1'-0" PROPOSED REAR ELEVATION: WEST SCALE : 3/16" = 1'-0" PROPOSED RIGHT SIDE ELEVATION: NORTH SCALE : 3/16" = 1'-0" PROPOSED LEFT SIDE ELEVATION: SOUTH METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-5.0 Coker Residence PC2 6-30-17.pln7/5/20174:05 PMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 7-05-1718'-0"18'-0"15'-51/2"15'-7"16'-10"PROPOSED GRADE EXISTING GRADE INDICATES 12' WIDE PROPOSED EMERGENCY VEHICLE ACCESS ROAD INDICATES 20 FT WIDE E.V.A.E. INDICATES 13.5 FT VERTICAL CLEARANCE FOR EMERGENCY VEHICLES EXISTING GRADE & PROPOSED GRADE AT WALL FACE= 721.83' INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES EXISTING GRADE AT THE FACE OF THE WALL INDICATES 18' VERTICAL DISTANCE FROM THE EXISTING GRADE AT WALL FACE ABOVE CELLAR INDICATES 18' VERTICAL DISTANCE FROM THE PROPOSED GRADE INDICATES PROPOSED GRADE INDICATES EXISTING GRADE INDICATES 18' VERTICAL DISTANCE FROM THE PROPOSED GRADE AT SECTION LINE THROUGH HIGH POINT GARAGE F.SLAB = 722.12' BASEMENT F. SLAB = 710.75' ( -11'-3") T.P.= 731.83' (+ 9'-10") T.P.= 737.50' (+ 15'-6") T.P.= 734.00' (+ 12'-0") H.P. = 738.85' H.P. = 737.52' H.P. = 736.58' T.P.= 734.00' (+ 12'-0") F.F.= 722.00' (± 0'-0") H.P. = 739.81' 3 CAR GARAGE FRONT COURTYARD 4 %SLOPE MAX. CUT 20' 12' HER CLOSET HIS CLOSET MASTER BEDROOM SUITE 3'-11" A 17'-11 1/2"17'-101/2"T.P.= 732.50' (+ 10'-6") F.F.= 722.00' (± 0'-0") BASEMENT F. SLAB = 710.75' ( -11'-3") T.P.= 731.83' (+ 9'-10") T.P.= 737.50' (+ 15'-6") F.F.= 722.00' (± 0'-0") H.P. = 739.81' EXISTING GRADE & PROPOSED GRADE AT WALL FACE= 721.83' INDICATES 18' VERTICAL DISTANCE FROM THE EXISTING GRADE AT WALL FACE ABOVE CELLAR H.P. = 736.58' H.P. = 738.62'H.P. = 738.84'H.P. = 738.61'H.P. = 736.54' F.G. = 721.00' INDICATES PROPOSED FINISHED GRADE INDICATES EXISTING GRADE GRAND FOYER GREAT ROOMCOURTYARD BEDROOM 3 BEDROOM 4VESTIBULE PORCH GOLF SIMULATIONRECREATION ROOM B c 15'-0"INDICATES 15' VERTICAL DISTANCE FROM THE PROPOSED GRADE AT WALL FACE INDICATES PROPOSED FINISHED GRADE AT THE FACE OF THE WALL INDICATES EXISTING GRADE AT THE FACE OF THE WALL F.G. = 720.00' T.P.= 730.67' (+ 10'-0") F.F = 720.67' (± 0.00') H.P. = 734.91' BEDROOMCOVERED VERANDA SECTION A-A D.Z. 1/8" = 1'-0" PROPOSED SECTIONS SCALE : 1/8" = 1'-0" SECTION B-B SCALE : 1/8" = 1'-0" SECTION C-C SCALE : 1/8" = 1'-0" SECTION A-A SECTION B-B SECTION C-C L0 Coker MN JB 5/30/2017 Coker.vwx Water Use20102 Foster RoadLandscape Design20102 Foster RdCalculations Reviewed by: Drawn by: Date: Jenna Bayer Garden Design, Inc. 1954 Old Middlefield Way Suite B Mountain View Californa 94043 Tel: 650.988.9600 Fax: 650.988.9602 info@jennabayer.com www.jennabayer.com Issued for: Project ID: CAD File:Los Gatos, CA 95030Date: Tue, May 30, 2017Time: 8:35:38 AMFile name: Coker LOCAL.vwxModel Water Efficient Landscape Ordinance Compliance OWNER Acknowledgement Signature* Email Address Phone Number Signature Date *Signer of the landscape design plan, signer of the irrigation plan, or a licensed landscape contractor or in compliance with DWR Doc. Print Full Name Phone or Email Certificate of Completion Water Efficient Landscape Worksheet Water Budget Calculator for New and Rehabiliated Landscapes Landscape Instructions Title 24, Part 11, California Green Building Code (CALGreen) http://www.bsc.ca.gov/Home/CALGreen.aspx State Model Water Efficient Landscape Ordinance http://www.water.ca.gov/wateruseefficiency/landscape ordinance/docs/Title%2023%20extract%20-%20Official%20CCR%20pages.pdf State Model Water Efficient Landscape Ordinance Resourceshttp://www.water.ca.gov/wateruseefficiency/landscapeordinance/GB-2Project: New House, 999 Matadero Avenue, Palo Alto CA 94306WATER USE CALCULATIONSAPPLICATION: This plan sheet is fo use by new landscpae > 500 SF, rehabiliated landscape of >2500 SF or landscape < 2,500 SF. RESIDENTIAL GREEN BUILDING APPLICATION WATER USE Certification Of Installation According to the Landscape Documentation Package PART 3. IRRIGATION SCHEDULING Attach parameters for setting the irrigation schedule on controller per ordinance Section 492.10. PART 4. SCHEDULE OF LANDSCAPE AND IRRIGATION MAINTENANCE Attach schedule of Landscape and Irrigation Maintenance per ordinance Section 492.11. PART 5. LANDSCAPE IRRIGATION AUDIT REPORT Attach Landscape Irrigation Audit Report per ordinance Section 492.12. PART 6. SOIL MANAGEMENT REPORT Attach soil analysis report, if not previously submitted with the Landscape Documentation Package per ordinance Section 492.6. Attach documentation verifying implementation of recommendations from soil analysis report per ordinance Section 492.6. LANDSCAPE DOCUMENTATION PACKAGE This project is required to comply with the State California Green Building Code (T24 Part 11) and the City of Palo Alto's local amendments (PAMC 16.14). I, the property owner / legal representative, acknowledge and understand the requirements and penalties for noncompliance ($50 per ton of waste not diverted from the landfill with a minimum of $1000, and $500 a day for noncompliance with the remaining green building measures). I am responsible for all activities performed by design team members, contractors and subcontractors in meeting the requirements. CERTIFICATION - SIGN & SUBMIT PRIOR TO BUILDING PERMIT FINAL INSPECTION I certify that based upon periodic site observations, the work has been substantially completed in accordance with the ordinance and that the landscape planting and irrigation installation conform with the criteria and specifications of the approved Landscape Documentation Package. Print Name and Company of Landscape Architect or Irrigation Designer Model Water Efficient Landscape Ordinance Compliance OWNER Acknowledgement Signature* Email Address Phone Number Signature Date *Signer of the landscape design plan, signer of the irrigation plan, or a licensed landscape contractor or in compliance with DWR Doc. Print Full Name Phone or Email Certificate of Completion Water Efficient Landscape Worksheet Water Budget Calculator for New and Rehabiliated Landscapes Landscape Instructions Title 24, Part 11, California Green Building Code (CALGreen) http://www.bsc.ca.gov/Home/CALGreen.aspx State Model Water Efficient Landscape Ordinance http://www.water.ca.gov/wateruseefficiency/landscape ordinance/docs/Title%2023%20extract%20-%20Official%20CCR%20pages.pdf State Model Water Efficient Landscape Ordinance Resourceshttp://www.water.ca.gov/wateruseefficiency/landscapeordinance/GB-2Project: New House, 999 Matadero Avenue, Palo Alto CA 94306WATER USE CALCULATIONSAPPLICATION: This plan sheet is fo use by new landscpae > 500 SF, rehabiliated landscape of >2500 SF or landscape < 2,500 SF. RESIDENTIAL GREEN BUILDING APPLICATION WATER USE Certification Of Installation According to the Landscape Documentation Package PART 3. IRRIGATION SCHEDULING Attach parameters for setting the irrigation schedule on controller per ordinance Section 492.10. PART 4. SCHEDULE OF LANDSCAPE AND IRRIGATION MAINTENANCE Attach schedule of Landscape and Irrigation Maintenance per ordinance Section 492.11. PART 5. LANDSCAPE IRRIGATION AUDIT REPORT Attach Landscape Irrigation Audit Report per ordinance Section 492.12. PART 6. SOIL MANAGEMENT REPORT Attach soil analysis report, if not previously submitted with the Landscape Documentation Package per ordinance Section 492.6. Attach documentation verifying implementation of recommendations from soil analysis report per ordinance Section 492.6. LANDSCAPE DOCUMENTATION PACKAGE This project is required to comply with the State California Green Building Code (T24 Part 11) and the City of Palo Alto's local amendments (PAMC 16.14). I, the property owner / legal representative, acknowledge and understand the requirements and penalties for noncompliance ($50 per ton of waste not diverted from the landfill with a minimum of $1000, and $500 a day for noncompliance with the remaining green building measures). I am responsible for all activities performed by design team members, contractors and subcontractors in meeting the requirements. CERTIFICATION - SIGN & SUBMIT PRIOR TO BUILDING PERMIT FINAL INSPECTION I certify that based upon periodic site observations, the work has been substantially completed in accordance with the ordinance and that the landscape planting and irrigation installation conform with the criteria and specifications of the approved Landscape Documentation Package. Print Name and Company of Landscape Architect or Irrigation Designer Model Water Efficient Landscape Ordinance Compliance OWNER Acknowledgement Signature* Email AddressPhone Number Signature Date *Signer of the landscape design plan, signer of the irrigation plan, or a licensed landscape contractor or in compliance with DWR Doc. Print Full Name Phone or Email Certificate of Completion Water Efficient Landscape Worksheet Water Budget Calculator for New and Rehabiliated Landscapes Landscape Instructions Title 24, Part 11, California Green Building Code (CALGreen) http://www.bsc.ca.gov/Home/CALGreen.aspx State Model Water Efficient Landscape Ordinance http://www.water.ca.gov/wateruseefficiency/landscape ordinance/docs/Title%2023%20extract%20-%20Official%20CCR%20pages.pdf State Model Water Efficient Landscape Ordinance Resourceshttp://www.water.ca.gov/wateruseefficiency/landscapeordinance/GB-2Project: New House, 999 Matadero Avenue, Palo Alto CA 94306WATER USE CALCULATIONSAPPLICATION: This plan sheet is fo use by new landscpae > 500 SF, rehabiliated landscape of >2500 SF or landscape < 2,500 SF. RESIDENTIAL GREEN BUILDING APPLICATION WATER USE Certification Of Installation According to the Landscape Documentation Package PART 3. IRRIGATION SCHEDULING Attach parameters for setting the irrigation schedule on controller per ordinance Section 492.10. PART 4. SCHEDULE OF LANDSCAPE AND IRRIGATION MAINTENANCE Attach schedule of Landscape and Irrigation Maintenance per ordinance Section 492.11. PART 5. LANDSCAPE IRRIGATION AUDIT REPORT Attach Landscape Irrigation Audit Report per ordinance Section 492.12. PART 6. SOIL MANAGEMENT REPORT Attach soil analysis report, if not previously submitted with the Landscape Documentation Package per ordinance Section 492.6. Attach documentation verifying implementation of recommendations from soil analysis report per ordinance Section 492.6. LANDSCAPE DOCUMENTATION PACKAGE This project is required to comply with the State California Green Building Code (T24 Part 11) and the City of Palo Alto's local amendments (PAMC 16.14). I, the property owner / legal representative, acknowledge and understand the requirements and penalties for noncompliance ($50 per ton of waste not diverted from the landfill with a minimum of $1000, and $500 a day for noncompliance with the remaining green building measures). I am responsible for all activities performed by design team members, contractors and subcontractors in meeting the requirements. CERTIFICATION - SIGN & SUBMIT PRIOR TO BUILDING PERMIT FINAL INSPECTION I certify that based upon periodic site observations, the work has been substantially completed in accordance with the ordinance and that the landscape planting and irrigation installation conform with the criteria and specifications of the approved Landscape Documentation Package. Print Name and Company of Landscape Architect or Irrigation Designer New Residence 20102 Foster Rd. Los Gatos California 95030 "A Landscape Irrigation Audit is required . This Audit must be completed by a Certified Landscape Irrigation Auditor, not the designer or installer. The Audit must be submitted to the Building Department , with a Certificate of Completion (Appendix C) as required by the Department of Water Resources , prior to scheduling a Final Inspection of the Water Efficient Landscape permit." TOTAL AND SPECIAL LANDSCPED AREA 23,978 square feet 726 square feet HYDROZONE TABLE 1lowSub-Surface0.301,2060.719,60113,522 2lowSub-Surface0.302,3510.7118,71626,360 3lowSub-Surface0.304640.713,6945,203 4lowSub-Surface0.302230.711,7752,500 5HighSprinkler0.704010.717,44910,491 6lowSub-Surface0.302180.711,7352,444 7lowdrip0.30150.71119168 8lowSub-Surface0.309610.717,65010,775 9LowSub-Surface0.301,3680.7110,89015,339 10 low Sub-Surface 0.00 522 0.71 0 0 11 Moderate Sub-Surface 0.00 0 0.71 0 0 12 High Sub-Surface 0.00 0 0.71 0 0 13 High Sub-Surface 0.00 0 0.71 0 0 14 Moderate Sub-Surface 0.00 0 0.71 0 0 15 low Sub-Surface 0.00 0 0.71 0 0 16 low Sub-Surface 0.00 0 0.71 0 0 17 low Sub-Surface 0.00 0 0.71 0 0 18 low Sub-Surface 0.00 0 0.71 0 0 19 low Sub-Surface 0.00 0 0.71 0 0 20 Moderate Sub-Surface 0 0 0.71 0 0 SLA 1.00 726 Total 8,455 61,630 86,803 * MAWU and ETWU 451,176 gallons/yr 106,068 gallons/yr 0.71 gallons/yr Yes Yes Hydrozone Area (sq ft) Plant Water Requirement (gal/yr) 42.8*0.62*PF*HA Average Irrigation Efficiency WATER BUDGET CALCULATION FORM Enter Total Landscaped Area (LA) Enter Special Landscaped Area (SLA) Estimated Total Water Use (ETWU) Irrigation Efficiency (min avg 0.70) Hydrozone Plant Water Use Type Plant Factor* Authorized Professional Name/Company : Property Address : License or Certification No : Project Meets Irrigation Efficiency Requirements CITY STAFF REVIEW ❑ YES, ETWU < MAWA ❑ NO, ETWU > MAWA Initials ____________ Zone Water Requirement (gal/yr) 42.8*0.62*PF*HA/IE Irrigation Type 20102 Foster Road Los Gatos JENNA BAYER GARDEN DESIGN, INC. ASLA 3890 Project Meets Water Efficient Requirements Max Allowable Water Use (MAWA) Professional Seal ___________________________________________________ Signature of Certified/Licensed Professional Date Use WUCOLS to determine PF: www.water.ca.gov/wateruseefficiency/docs/wucols00.pdf. Note that surface areas of a water feature will be counted as high water using plant at PF 1.30'-0"SSSSSS SS SSSSW22'-6"30'-4"36' -41/2 "40'-1" F O S T ER ROAD UP UP COURTYARD PLANTER PLANTER3 - GARAGE COVERED VERANDA POOL COVERED VERANDA PLANTER PLANTER PLANTER PLANTER 2 % SLOPE ACCESSORY BUILDING PROPOSED SINGLE STORY RESIDENCE REAR SETBACK LINEFRONT SETBACK LINESIDE SETBA C K LINE POOL EQUIP.740735730725725720730 735730725715710715710N 71°56'26" W178.26'R=86.93'D=51°07'18"L=77.56'R=142 .91' Δ=77°24'59"L=193.10' (Δ=77°25'09") R=106.94'Δ=9°56'53"L=18.57' R=162 .91' Δ=77°36' 4 8 " L = 2 2 0 .6 8 ' N 00°09'11" E304.71' S 4 7 ° 3 5 ' 3 9 " W 3 5 .3 1 ' L = 3 6 .8 9 L=52.61 SPA LOWER TERRACE E 4" HDPE6" HDPE 8" HDPE~~6"6"15" HDPESD15" HDPESDSD15" HDPE8" HDPE WV WM RIM 723.09SSCO 723.4ELEC. MARKER 723.80TB723.77FOB72 3 .4 7 CA T V FO FOSSMHRIM 724.38 20'-0" 12'-0" FND. MON 720723F.F. = 722'-0" F.S. = 722'-0" F.S. = 722'-0"F.S. = 722'-0" CELLAR F.S. = 710'-9" F.S . = 720'-8"721719718 717 717 718720PRIVATE STORMDRAINAGE EASEMENT12'-0"PLANTER720 719 G 4" HDPE 25'-0"20'-0" 1 1 2 33 4 4 6 7 5 8 8 8 9 10 522 SF 407 SF 799 SF 2,351 SF 304 SF161 SF 75 SF 148 SF 218 SF 401 SF SLA 726 SF 211 SF 102 SF 648 SF 1,368 SF 15 SF on 24" x 36" Hydrozone Plan Scale: 1" = 20 ft 1 L0 0 5 10 15 20 25 30 35 40 45 50 FT RESIDENCE L6 Coker MN JB 5/30/2017 Coker.vwx PlantingCoker ResidenceLandscape Design20102 Foster RdPlan Reviewed by: Drawn by: Date: Jenna Bayer Garden Design, Inc. 1954 Old Middlefield Way Suite B Mountain View Californa 94043 Tel: 650.988.9600 Fax: 650.988.9602 info@jennabayer.com www.jennabayer.com Issued for: Project ID: CAD File:Los Gatos, CA 95030Date: Tue, May 30, 2017Time: 7:34:39 AMFile name: Coker LOCAL.vwxMETRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : A-2.0 Coker Residence 2-07-17.pln3/23/201710:10 AMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 3-08-17 142'-51/2" 34'-1/2"44'-7"57'-10"6'-0" 13'-1/2"21'-0"16'-11/2"12'-2"16'-31/2"9'-91/2"12'-11/2"10'-0"3'-111/2"18'-0"3'-111/2"6'-0"22'-91/2"6'-0"29'-51/2"30'-11"21'-0"7'-1"117'-21/2"4'-111/2"28'-51/2"23'-5"26'-0"34'-6"117'-4"142'-51/2" 21'-91/2"21'-3"10'-111/2"20'-7"19'-5"42'-5"6'-0"22'-4"17'-51/2"12'-51/2"29'-41/2"1'-61/2"21'-9"8'-81/2"8'-0"8'-91/2"25'-0" 14'-9"4'-0"14'-9" 12'-11/2"21'-0"21'-0"21'-0"33'-11/2" A A-5.0 A A-5.0 B A-5.0 B A-5.0 INDICATES 20'-0" x 20'-0" CLEAR - REQUIRED 2 CARS PARKING DIMENSIONS INDICATES 11'-0" x 20'-0" CLEAR - REQUIRED 1 CAR PARKING DIMENSIONS 3 - GARAGE HER CLOSET HIS CLOSET MASTER BEDROOM SUITE MASTER BATH LINEN & STORAGE ELEV. FOYER DINING ROOM LIBRARY PORCH SEE - THRU FIREPLACE WASHER &DRYER MUD ROOM KITCHEN GREAT ROOM FIREPLACE BALCONY COURTYARD COVERED VERANDA TOILET LINEN 1/2 BATH PANTRY BATH 3 BEDROOM 2 VANITY BATH 2 SO CM REF FRZ VERANDA WINEPLANTER PLANTER CLO. 14'-0" x 14'-0" BEDROOM 3 14'-0" x 14'-0" BEDROOM 4 12'-0" x 12'-0" NOOK 12'-9" x 12'-9" 13'-3" x 21'-3"23'-6" x 22'-6"23'-0" x 22'-0" 14'-6" x 18'-0" 13'-6" x 18'-4" 18'-3" x 25'-0" 21-0" x 20'-6" 14'-0" x 17'-0" 8'-0" x 12'-4" 10'-0" x 12'-0" VESTIBULE PORCH 7'-0" x 10'-8" SHOWER DN WINEDN BATH 4 STORAGE PLANTERHILLSIDE GARDEN AREA N24'-11" 23'-2" 1'-101/2"21'-21/2"1'-101/2"10'-31/2"10'-31/2"22'-31/2"11'-61/2"10'-9"BEDROOM BATH COVERED VERANDA 10'-0" x 12'-0" C A-5.0 C A-5.0 MAIN FLOOR PLAN TS 1/8" = 1'-0" PROPOSED MAIN FLOOR PLAN ACCESSORY BUILDING FLOOR PLAN 30'-0"SSSSSSSSSS SS SS SS SSSSSSWW22'-6"30'-4"36' -41/2"40'-1" F O S T E R R OAD UP UP COURTYARD PLANTER PLANTER 3 - GARAGE COVERED VERANDA POOL COVERED VERANDA PLANTER PLANTER PLANTER PLANTER 2 % SLOPE ACCESSORY BUILDING PROPOSED SINGLE STORY RESIDENCE REAR SETBACK LINEFRONT SETBACK LINESIDE SETBA C K LINE POOL EQUIP.740735730725725720730 735730725715710715710N 71°56'26" W178.26'R=86.93'D=51°07'18"L=77.56'R=142 .91' Δ=77°24'59"L=193.10' (Δ=77°25'09") R=106.94' Δ =9°56'53" L=18 .57' R=162 .91' Δ=77°36' 4 8 " L = 2 2 0 .6 8 ' N 00°09'11" E 304.71' S 4 7 ° 3 5 ' 3 9 " W 3 5 .3 1 ' L=52.61 SPA LOWER TERRACE E 4" HDPE6" HDPE 8" HDPE~6"6"15" HDPESD15" HDPESDSD15" HDPE8" HDPE WV WM RIM 723.09 SSCO 723.4 ELEC. MARKER 723.80TB723.77FOB72 3 .4 7 CA T V FO FOSSMH 20'-0" 12'-0" FND. MON 720723F.F. = 722'-0" F.S. = 722'-0" F.S. = 722'-0"F.S. = 722'-0" CELLAR F.S. = 710'-9" F.S. = 720'-8"721719718 717 717 718720PRIVATE STORMDRAINAGE EASEMENT12'-0"PLANTER720 719 G 4" HDPE 25'-0"20'-0" 11" OAK 18" OAK 21" OAK 20" BAY 15" BLUE OAK 26" BLUE OAK 2 3 4 1 7 6 Lawn-380 sq ft 100%-G158-Double Dwarf Bonsai Fescue 75 G159 Juncus patens California Grey Rush74 G159 Juncus patens California Grey Rush 1 S166 Arbutus unedo Compact Strawberry Bush 8 S239 Arctostaphylos u-u Kinnikinick (E) TO REMAIN, NO (N) PLANTING 19 S46 Ceanothus x 'Dark Star' Dark Star California Lilac 3 S239 Arctostaphylos u-u Kinnikinick Driveway Island-812 sq ft 25%-S46-Ceanothus x 'Dark Star' 25%-S52-Cistus x 'Bennet's White' 25%-P26-Phormium Tenax 2 S41 Laurus nobilis 'Saratoga' Sweet Bay North Front Yard-1844 sq ft 25%-S46-Ceanothus x 'Dark Star' 25%-S52-Cistus x 'Bennet's White' 25%-P26-Phormium Tenax South Front Yard-443 sq ft 25%-S46-Ceanothus x 'Dark Star' 25%-S52-Cistus x 'Bennet's White' 25%-P26-Phormium Tenax 30' HOUSE ZONE 30' HOUSE ZONE 30' HOUSE ZONE NO (N) PLANTING 96 G159 Juncus patens California Grey Rush 42 G159 Juncus patens California Grey Rush 30' HOUSE ZONE1 T109 Quercus agrifolia Coast Live Oak 116 G159 Juncus patens California Grey Rush 82 G159 Juncus patens California Grey Rush 33 G159 Juncus patens California Grey Rush 1 S167 Dodonaea viscosa 'Purpurea' Purple Hopseed Bush 1 S41 Laurus nobilis 'Saratoga' Sweet Bay 108 G159 Juncus patens California Grey Rush 1 S41 Laurus nobilis 'Saratoga' Sweet Bay BIOSWALE Access Road-156 sq ft 25%-S46-Ceanothus x 'Dark Star' 25%-S52-Cistus x 'Bennet's White' 25%-P26-Phormium Tenax on 24" x 36" Planting Plan Scale: 1" = 10 ft 1 L6 0 5 10 15 20 25 30 35 40 45 50 FT RESIDENCE Plant Schedule Image ID Qty Latin Name Common Name Scheduled Size Remarks S166 1 Arbutus unedo Compact Strawberry Bush Multi 24" box Native S239 11 Arctostaphylos u-u Kinnikinick 5 gal Native S46 182 Ceanothus x 'Dark Star'Dark Star California Lilac 5 gal Native S52 163 Cistus x 'Bennet's White'Bennet`S White Rock Rose 5 gal Native S167 1 Dodonaea viscosa 'Purpurea'Purple Hopseed Bush 5 gal Native G158 4 Double Dwarf Bonsai Fescue per area G159 626 Juncus patens California Grey Rush Native S41 4 Laurus nobilis 'Saratoga'Sweet Bay 15 gal P26 163 Phormium Tenax Bronze Baby New Zealand 1 gal T109 1 Quercus agrifolia Coast Live Oak 24" box Native METRO GROUP DESIGN DATE : SCALE : PROJECT NO : DRAWN BY : L-1.0 Coker Residence 2-07-17.pln3/23/201710:12 AMThe plans, ideas and design on this drawing are the property of the designer,divised solely for this contract. Plans shall not be used, in whole or in part, for any purpose for which they were not intended without the written permission of METRO DESIGN GROUP. c REVISIONS ARCHITECTURE PLANNING INTERIORS.. 1475 S. BASCOM AVE SUITE 208 CAMPBELL, CA 95008 (408)871-1071 phone (408)871-1072 fax www.metroarchitects.com SHEET NUMBER CHECKED BY :TS ARCHITECT :TOM SLOAN PROJECT NAME 20102 FOSTER ROAD LOS GATOS, CA 95030 COKER RESIDENCE 16629 3-08-17 2 3 4 1 5 8 7 6 A1.1 2 T1 1 T2 T3 3 2 3 4 5 6 7 8 T4 T5 T1 G1 G2 G3 S1 S2 S3 S4 S5 T2 T2 T2 T3 T5 T3 T4 T4 T4 T3 T5 T5 G1 G2 G2 G2 G2 G2G2 G2 G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 S1 S1 S1 S1 S2 S2 S2 S2 S2 S3 S3 S3 S3 S3 S3 S4 S5 S5 S3 S5 605 sq. ft. 154 sq.ft. 2,044 sq.ft. 719.09 CLF EXISTING GATE TO REMAIN 719.43 CLF INDICATES MAX. 6'-0" HIGH FENCE - TYP. INDICATES MAX. 6'-0" TALL WOOD FENCE WITH TOP AND BOTTOM RAIL AND 6 x 6 BROWN PVC VINYL COATED WELDED WIRE FENCING F O S T E R R OAD UP UP POOL COVERED VERANDA ACCESSORY BUILDING PROPOSED SINGLE STORY RESIDENCE POOL EQUIP.740735730725725720730735730715710710N 71°56'26" W178.26'R=86.93'D=51°07'18"L=77.56'R =142 .91 ' ∆=77°24'59"L=193.10' (∆=77°25'09") R =106.94' ∆=9 °56'53" L =18.57' R =162 .91 '∆=77°36'48" L=22 0.68' N 00°09'11" E 304.71' S 47°35'39" W 35.31' L=36.89 L=52.61 SPA 11" OAK 18" OAK 13" BLUE OAK 26" BLUE OAK LOWER TERRACE STREET LIGHT BOX TREE SIZE EXISTING TREE LEGEND PER ARBORIST REPORT DATED 1/8/2016 PREPARED BY WALTER LEVISON GENUS & SPECIES LARGEPROTECTEDTREE ?PLEASE SEE THE ARBORIST REPORT FOR MORE INFORMATION LAWN LAWN 'UC VERDE' PROPERTY LINE SETBACK LINE (E) GRADE MINOR CONTOUR LINE (E) GRADE MAJOR CONTOUR LINE INDICATES MAX. 6'-0" TALL WOOD FENCE WITH TOP AND BOTTOM RAIL AND 6 x 6 BROWN PVC VINYL COATED WELDED WIRE FENCING EXISTING TREE TO REMAIN PROPOSED RESIDENCE PROPOSED DRIVEWAY PROPOSED HARDSCAPE LIMESTONE ANTIQUE FINISH DECOMPOSITE GRANITE Grasspave2 @ EMERGENCY VEHICLE ACCESS ROAD BUCHLOE DACTYLOIDES 'UC VERDE' (UC VERDE BUFFALOGRASSES) 2,044 SQ. FT. LAWN 759 SQ. FT. 21" OAK ALL EXISTING TREES TO REMAIN AND TO BE PROTECTED DURING CONSTRUCTION -TYP. 20" BAY SEE DETAIL 60" BAY CONTRACTOR YO VERIFY THAT ALL SOIL IS BELOW THE HOUSE STUCCO LINE BY 5". NO MULCH SHOULD COME WITHIN 3" OF STUCCO LINE. 5% MIN, AWAY FROM THE STRUCTURESLOPE AT LANDSCAPE AREAS: 2% MIN, AWAY FROM THE STRUCTURE 1% MIN, AWAY FROM THE STRUCTURESLOPE AT LANDING AREAS: SLOPE AT PAVED AREAS: LANDSCAPE PLAN LEGEND PLANT NOTES: 15" BLUE OAK 21" OAK TREE TAGNO.QUERCUS AGRIFOLIA COAST LIVE OAK QUERCUS AGRIFOLIA UMBELLULARIA CALIFORNICA QUERCUS AGRIFOLIA QUERCUS DOUGLASIL COAST LIVE OAK UMBELLULARIA CALIFORNICA QUERCUS DOUGLASIL QUERCUS DOUGLASIL CALIFORNIA BAY LAUREL COAST LIVE OAK CALIFORNIA BAY LAUREL BLUE OAK BLUE OAK BLUE OAK 21" 11" 20" 18" 60" 26" 15" 13" NO NO NO NO YES YES NO NO LATIN NAME PLANT LIST COMMON NAMEID QTYSCHEDULED SIZE QUERCUS AGRIFOLIA COAST LIVE OAK 36" BOX 1 OLEA EUROPAEA 'SWAN HILL' (MULTI)SWAN HILL OLIVE 5 GAL 3 LAGERSTROEMIA INDICA 'ACOMA'ACOMA CRAPE MYRTLE 24" BOX 3 FRUIT TREE 15 GAL 7 OLEA 'LITTLE OLLIE'7LITTLE OLLIE OLIVE 5 GAL BUCHLOE DACTYLOIDES 'UC VERDE''UC VERDE' BUFFALOGRASS 1 GAL 2,044 SQ. FT. MUHLENBERGIA CAPILLARIS PINK MUHLY 1 GAL 83 HELICTOTRICHON SEMPERVIRENS BLUE OAT GRASS 1 GAL 77 CEANOTHUS X 'DARK STAR'DARK STAR CALIFORNIA LILAC 5 GAL 12 CISTUS X 'BENNET'S WHITE'BENNET'S WHITE ROCK ROSE 5 GAL 26 CISTUS X 'BRILLIANCE' (C. X 'SUNSET')BRILLIANCY ROCK ROSE 5 GAL 31 DODONAEA VISCOSA 'PURPUREA'PURPLE HOPSEED BUSH 5 GAL 10 ACROSTAPHYLOS DENSIFLORA 'HOWARD McMINN'McMINN'S MANZANITA 5 GAL 12 COMMON NAME NOTES: 1. IRRIGATION TO BE LOW WATER, CALGREEN COMPLIANT. 2. REFER TO GRADING AND DRAINAGE PLAN, SHEET C-4.0 FOR SITE DRAINAGE. 3. EXISTING TREES ON THE SITE ARE ALL IN NATURAL AREA, NOT TO BE DISTURBED OR REMOVED. 4. SEE ARBORIST REPORT FOR MORE INFO REGARDING EXISTING TREES. 5. PLANTING PLAN AS SHOWN ON PLAN. 6. FENCE AS SHOEN ON PLAN. 7. LANDSCAPE DESIGN TO BE IN COMPLIANCE WITH TOWN OF LOS GATOS HILLSIDE DEVELOPMENT STANDARDS AND GUIDELINES, SPECIFICALLY SECTION 7, CALGREEN CODE AND GREEN POINT CHECKLIST. E G CO 4" HDPE4" HDPE6" HDP E 6" HDPE ~8" HDPE~~6" H D P E6"6"15" HDPESD15" HDPESDSD15" HDPE12" PVC 8" HDPE ~RIM 723.09 SSCO 723.80TB723.77FOB72 3.47CA T V FOFOGRAPHIC SCALE: (IN FEET) 10 0 5 10 20 30 NEW 2" WATERWV WM NLANDSCAPE PLAN DZ 1/16" = 1'-0" QUERCUS DOUGLASII QUERCUS DOUGLASII QUERCUS DOUGLASII 1 NOTE: NO TREES TO ENCROACH ON FIRE LANE 100% NATIVE NOTE: 80% OF NEW PLANTS ARE NATIVE/INDIGENOUS TO LOCAL AREA