Ord 1849 - Amending Articles I through IX of Chapter 7 of the Town Code Relating to Building Reguations and to Adopt the 1988 Building Standard Regulations with 1989 State of California AmendmentsORDINANCE 1849 ORDINANCE OF THE TOWN OF LOS GATOS AMENDING ARTICLES I THROUGH IX OF CHAPTER 7 OF THE TOWN OF LOS GATOS TOWN CODE RELATING TO BUILDING REGULATIONS AND TO ADOPT THE 1988 BUILDING STANDARD REGULATIONS WITH 1989 STATE OF CALIFORNIA AMENDMENTS THE TOWN COUNCIL OF THE TOWN OF LOS GATOS DOES HEREBY SECTION I Article I of Chapter 7 of the Town Code is hereby repealed in its entirety. SECTION II Article I of Chapter 7 of the Town Code is enacted to read as follows: ARTICLE I ADMINISTRATION OF CODES Section 7.01.010 - Adoption of 1988 Building Standard Regulations The Uniform Administrative Code, 1988 Edition, including the 1989 State of California amendments Chapter 14 contained in State Building Standard Regulations (Title 24) are hereby adopted by reference with the modifications and omissions as provided in Section 7.01.015 through 7.01.035. Section 7.01.015 - Board of Appeals In order to determine the suitability of alternate materials and methods of construction and to provide for reasonable interpretation and application of the provisions of this code, the Town Council is a board of appeals. When the Town Council is acting as the Board of Appeals, the building official shall attend its sessions. The Town Council, as Board of Appeals, may adopt reasonable rules and regulations for limiting the time for appeals and concerning procedures, for conducting its investigations and shall render all decisions and findings in writing to the building official with a duplicate copy to the appellant. Section 7.01.020 - Appeal Notice Any interested person may appeal to the Board of Appeals from any decision of the building official. The appellant must file a written notice of appeal with the town clerk not more than thirty (30) days after the decision is rendered. The notice shall state clearly the decision or matter being appealed. Section 7.01.025 - Hearing The appeal shall be heard by the Council within forty -five (45) days after the filing of the appeal. The board of appeals may continue from time to time any hearing held. The town clerk shall set the hearing date for the appeal and shall give notice such hearing to the appellant and the permittee and publish a notice in a newspaper of general circulation for ten (10) days. Section 7.01.030 - Building Official's Report The Building Official shall, four (4) days prior the public hearing, submit to the board of appeals a report describing the decision or matter being appealed and basis for his action. Section 7.01.030 - Conduct of Hearing, Findings When hearing the appeal the board of appeals shall consider the building official's report, the applicable codes, regulations and standards involved and such additional evidence or testimony given at the hearing and may affirm, modify or reverse, in whole or part, the action being appealed. The decision of the council upon the appeal shall be expressed by a written resolution, a copy of which shall be transmitted to the original permittee, the appellant and the building official. If the decision of the board is adverse to that of the building official, the resolution shall contain findings used in making their decision. Section 7.01.035 - Violations Any person who does any work or causes any work to be done, or who occupies, or maintains any building or structure, or who causes the same to be done, contrary to or in violation of the provisions of this code, is guilty of an infraction. Such person is guilty of a separate offense for each day during any part of which a violation of any provision of this code is committed, continued, or permitted by such person and is punishable accordingly. SECTION III Article II of Chapter 7 of the Town Code is hereby repealed in its entirety. 2 SECTION IV Article II of Chapter 7 of the Town Code is enacted to read as follows: ARTICLE II BUILDING CODE Section 7.02.010 - Adoption of 1988 Uniform Building Code The Uniform Building Code, 1988 Edition, as amended in 1989 by the State of California in the State Building Standard Regulations (Title 24), with Appendix Chapters 11, 32, 35 and 49 with modifications and omissions provided in Sections 7.02.015 through 7.20.040 of this Article, is adopted by reference. Section 7.02.015 - Sections Deleted Each of the following sections of code adopted by this article is hereby deleted: 101, 102, 103, 104, 105, 106, 107, 201, 202, 203, 204, 205, 301, 302, 303, 304, 305, 306 and 307, respectively. Section 7.02.020 - Reference to Section Numbers Any reference in the code adopted by this article, commencing with Chapter 4, to any of the sections deleted by section 7.02.020 now refers to the successor section in Article II of this chapter. Section 7.02.025 - Table 29 -A, Relative to Reinforcing Foundations Table 29 -A of the code adopted by this article is amended by adding the following footnote: "Bearing foundation walls shall be provided with a minimum of two (2) one - half -inch diameter reinforcing steel rods. Placement shall be one (1) rod three (3) inches from the bottom and one (1) rod three (3) inches from the top of the foundation. Two (2) additional lower rods, each embedded in the foundation at least fifteen (15) feet of its length, shall be extended above grade to provide access for electrical ground connections." Section 7.02.030 - Section 3207(e) Roof Drainage Subsection 3207(e) of the code adopted by this article is amended to add additional exceptions to read as follows: 3 "Other occupancies where the drainage plan and method of drainage have been approved by the town engineer." Section 7.02.035 - Section 3205, Standpipes Subsection 3805(f) is added to the code adopted by this article to read: "(f) Limited omission. Separate standpipe may be omitted in buildings equipped throughout with an approved automatic sprinkler system; however, hose connections for fire department use, as specified in section 3073, National Fire Protection Association Pamphlet No. 13, shall be provided in all required stair enclosures. The static pressure at hose connections shall not exceed one hundred fifty pounds per square inch." SECTION V Article IV of Chapter 7 of the Town Code is hereby repealed in its entirety. SECTION VI Article IV of Chapter 7 of the Town code is enacted to read as follows: ARTICLE IV PLUMBING CODE Section 7.04.010 - Adopted The Uniform Plumbing Code, 1988 Edition, with appendix chapters A, B, C, D, E, H and I with modification and omissions provided in sections 7.30.015 through 7.30.025 of this article is adopted by reference. Section 7.04.015 - Installation standards adopted The IAMPO Installation Standards, as set out in the 1988 Uniform Plumbing Code, are adopted by reference. Section 7.04.020 - Amendments- Sections deleted Part I of the 1988 Plumbing Code is deleted. Section 7.04.025 - Same - References to section numbers Any reference in the code adopted by this article commencing with Chapter 1 to any of the sections deleted by section 6.50.020 now refers to the successor section in Article II of this Chapter. 2 SECTION VII Article V of Chapter 7 of the Town Code is hereby repealed in its entirety. SECTION VIII Article V of Chapter 7 of the Town Code is enacted to read as follows: ARTICLE V ELECTRICAL CODE Section 7.05.010 - Adopted The National Electrical Code, 1990 Edition, with modifications provided in sections 7.05.015 through 7.05.025 is adopted by reference. Section 7.05.015 - Same - Section 250 -81, grounding electrode Section 250 -81, Grounding Electrode System of the code adopted by this article, is amended by adding subsection (e) to read as follows: "(e) Where a concrete encased grounding electrode is installed as required by section 7.02.030, a supplementary grounding conductor shall be installed." Section 7.05.020 - Same- Section 300 -1, scope Section 300 -1, Scope, of the code adopted by this article, is amended by adding subsection (c) to read as follows: "(d) Buildings other than residential shall be wired in approved raceway. For the purpose of this section, hotels and motels are considered commercial buildings." Section 7.05.025 - Same - Section 336 -3, was permitted Section 336 -3, Uses Permitted, of the code adopted by the article, is revised to read as follows: "336 -3. Uses Permitted or Not Permitted" "Type NM and Type NMC cables shall be permitted to be used in one and two - family dwellings, or multifamily dwellings not exceeding three floors above grade. For the purpose of this article, the first floor of a building shall be that floor designed for human habitation which is level with or above finished grade of the exterior wall line of fifty (50) percent or more of its perimeter." 5 SECTION IX Article VII of Chapter 7 of the Town Code is hereby repealed in its entirety. SECTION X Article VII of Chapter 7 of the Town Code is enacted to read: ARTICLE VII UNIFORM CODE FOR THE ABATEMENT OF DANGEROUS BUILDINGS Section 7.07.010 - Adopted The Uniform Code for the Abatement of Dangerous Buildings, 1988 Edition, with modifications and omissions provided in sections 7.06.015 and 7.06.020 of this article is adopted by reference. Section 7.07.015 - Amendments- Sections deleted Each of the following sections of the code adopted by this article is deleted: 101, 102, 103, 201, 202, 203, 204 and 205. Section 7.07.020 - Same - References to section numbers Any reference in the code adopted by this article to any of the sections deleted in Section 7.06.015 shall be deemed to refer to the appropriate section of Article II of this Chapter. SECTION XII Article VIII of Chapter 7 of the Town Code is enacted to read: ARTICLE VIII UNIFORM MECHANICAL CODE Section 7.08.010 - Adoption The Uniform Mechanical Code, 1988 Edition, with Appendix Chapters A, B and C with modifications and omissions provided in sections 7.07.015 and 7.07.020 of this Article, is adopted by reference. 1 Section 7.08.015 - Sections deleted Each of the following sections of the Code is adopted by this Article is hereby deleted: 101, 102, 103, 104, 105 106, 107, 201, 202, 203, 204, 301, 302, 303, 304, 305 and 306. Section 7.08.020 - Reference to section numbers Any reference in the Code adopted by this Article, commencing with Chapter 4 to any of the sections deleted by section 7.08.015 now refers to the successor sections in Article 1 of this Chapter. SECTION XIII Article IX of Chapter 7 of the Town Code is hereby repealed in its entirety. SECTION XIV Article IX of Chapter 7 of the Town Code is enacted to read as follows: ARTICLE IX UNIFORM CODE OF BUILDING CONSERVATION Section 7.09.010 - Adoption of Uniform Code for Building Conservation The Uniform Code for Building Conservation, including appendices, is hereby adopted for the regulation of buildings, identified as unreinforced masonry buildings as defined by Section 8875 et seq. of the California Government Code and listed by the Town of Los Gatos as "unreinforced masonry buildings." Such list shall be maintained by the Building Official who may add or delete buildings based on his inspection and /or engineering analysis. This code shall pertain to altering, renovating and remodeling of buildings and structures, the issuance of permits therefor and enforcement thereof, which building code is as follows: All of the provisions of the Uniform Code for Building Conservation of 1985 of the International Conference of Building Officials, hereinafter termed the: "Conservation Code ", and each and all of the regulations, appendices, provisions, penalties, conditions and terms of such building code (one copy of which code has been filed for use and examination by the public in the Office of the Town Clerk) are referred to and are adopted and made a part hereof, the same as if fully set forth in this chapter, and are adopted as sections of this chapter bearing the same numerical sections, designations, titles as appear in the Conservation Code except as set forth in Section 7.08.010 through and including Section 7.08.020. 7 Section 7.09.015 - Sections Deleted Chapters 1 and 2 of the Conservation Code are hereby deleted. Section 7.09.020 - Modifications to Appendix - Chapter 1 The Appendix of Chapter 1 of the Conservation Code is hereby adopted as amended: APPENDIX CHAPTER 1 EARTHQUAKE HAZARD REDUCTION IN EXISTING UNREINFORCED MASONRY BUILDINGS PURPOSE Sec. A101. The purpose of this chapter is to promote public safety and welfare by reducing the risk of death or injury that may result from the effects of earthquakes on buildings of unreinforced masonry bearing wall construction. Such buildings have been widely recognized for their sustaining of life hazardous damage as a result of partial or complete collapse during past moderate to strong earthquakes. The provisions of this chapter are minimum standards for structural seismic resistance established primarily to reduce the risk of life loss or injury and will not necessarily prevent loss of life or injury or prevent earthquake damage to an existing building which complies with this chapter. SCOPE Sec. A102. The requirements of this chapter shall apply to all buildings containing unreinforced masonry bearing walls. Exception: This chapter shall not apply to a detached Group R, Division 3 Occupancy nor to a detached Group R, Division 1 Occupancy containing less than five dwelling units used solely for residential purposes. ALTERNATE MATERIALS Sec. A103. Alternate materials, designs and methods of construction may be approved by the Director of Building Services in accordance with the Building Code. DEFINITIONS Sec. A104. For the purpose of this chapter, certain terms are defined as follows: CROSS WALLS are interior walls of masonry or wood frame construction with surface finish of wood lath and plaster, minimum 1 /2- inch -thick gypsum wallboard or solid horizontal wood sheathing. In order to be considered as a cross wall within the intent of this chapter, the cross walls shall be spaced at not more than 40 feet apart in each story, and shall be full story height with a minimum length of one and one -half times the story height. UNREINFORCED MASONRY BEARING WALLS are masonry walls having all of the following characteristics: 1. Provide the vertical support for a floor or roof. 2. Have a total superimposed load over 100 pounds per linear foot. 3. Have an area of reinforcing steel less than 50 percent of that required by the Building Code. HISTORIC BUILDINGS Sec. A105. (a) General. A historic building may comply with the special provisions set forth in this chapter and the provisions of the State Historical Building Code. (b) Unburned Clay Masonry or Adobe. Existing or re- erected walls of adobe construction shall conform to the following: 1. Exterior bearing walls of unreinforced adobe masonry shall not exceed a height- or length -to- thickness ratio of 5:1. Such walls shall be provided with a reinforced bond beam at the top which interconnects all walls. The bond beam shall have a minimum depth of 6 inches. The bond beam may have a width equal to the width of the wall less 8 inches, provided the resulting width is not less than 8 inches. Minimum wall thickness shall be 18 inches for exterior bearing walls and 10 inches for adobe partitions. No adobe structure shall exceed one story in height unless the historic evidence satisfactory to the Director of Building Services indicates a two story height. In such cases the height -to- thickness ratio shall be the same as above for the first story based on the total two story wall height, and the second floor wall thickness shall not exceed the ratio of 5:1 by more than 20 percent. Bond beams shall be provided at the roof and second floor levels. 2. Foundations footings shall be reinforced concrete under newly reconstructed walls and shall be 50 percent wider than the wall above, soil conditions permitting, except that the foundation wall may be 4 inches less in width than the wall if rock, burned brick or stabilized adobe facing is necessary to provide authenticity. 3. New or existing unstabilized brick and adobe brick masonry shall test to 75 percent of the compressive strength required by the Building Code for new material. Unstabilized brick may be used where existing bricks are unstabilized and where the building is not susceptible to flooding or direct exposure to the weather. Adobe may be allowed a maximum value of 3 pounds per square inch for shear with no increase for lateral forces. X 4. Mortar may be of the same soil composition and stabilization as the brick in lieu of cement mortar. 5. Nominal tension stresses due to seismic forces normal to the wall may be neglected if the wall meets the thickness requirements and shear values allowed by this subsection. (c) Archaic Materials. Allowable stresses for archaic materials not specified in this code shall be based on substantiating research data or engineering judgement with the approval of the Director of Building Services. ANALYSIS AND DESIGN Sec. A106.(a) General. Every structure within the scope of this chapter shall be analyzed and constructed to resist minimum total lateral seismic forces assumed to act nonconcurrently in the direction of each of the main axes of the structure in accordance with the following equation: V = ZIKCSW ........................ (Al -1) The value of KCS need not exceed but shall not be less than .100 for one story buildings with less than 100 occupants; and need not exceed but must not be less than .133 for one story buildings containing 100 or more occupants and buildings over one story above grade. The value of Z and I shall equal 1.0. The value of W shall be as defined in Chapter 23 of the 1985 Uniform Building Code. (b) Lateral Forces on Elements of Structures. Parts or portions of buildings shall be analyzed and designed for lateral loads in accordance with Chapter 23 of the 1985 Uniform Building Code but not less than the value from the following equation: Fp = ICpSWp ...................... (Al -2) For the provisions of this section, the product of IS shall equal 1.0. The value of Cp shall be in accordance with Table 23 -J of the 1985 Uniform Building Code. The value of Wp shall be as defined in Chapter 23 of the 1985 Uniform Building Code. Exception: Unreinforced masonry walls may be designed in accordance with Section A107. (c) Regulated Elements of Buildings. The elements of buildings required to be analyzed by this chapter include: 1) Height -to- thickness ratio of masonry walls; (2) Tension bolts in bending; (3) in -plane shear stress; (4) Parapets; (5) Diaphragm stresses and diaphragm chords in floors and roof. (d) Anchorage and Interconnection. Anchorage and interconnection of all parts, portions and elements of the structure shall be analyzed and designed for lateral forces 10 in accordance with the 1985 Uniform Building Code and the Formula (Al -2) of this code. Masonry walls shall be anchored to all floors and roof to resist a minimum force of 200 pounds per linear foot acting normal to the wall at the level of the floor or roof. (e) Level of Required Repair. Alterations and repairs required to meet the provisions of this chapter shall comply with all other applicable requirements of the Building Code unless specifically provided for in this chapter. (f) Required Analysis. 1. General. Except as modified herein, the analysis and design relating to the structural alteration of existing buildings within the scope of this chapter shall be in accordance with the analysis specified in the 1985 Uniform Building Code. In addition the compatibility of the roof diaphragm stiffness with the out -of -plane stability of the unreinforced masonry walls of the story immediately below the roof shall be verified in accordance with the provisions of Section A109. Exception: Buildings with rigid concrete or steel and concrete roof diaphragms shall use the h/t values for all other buildings in Table Al -F. 2. Continuous load path. A complete, continuous load path from every part or portion of the structure to the ground shall be provided for the required horizontal forces. 3. Positive connections. All parts, portions or elements of the structure shall be interconnected by positive means. (g) Analysis Procedure 1. General. Stresses in materials and existing construction utilized to transfer seismic forces from the ground to parts or portions of the structure shall conform to the those permitted by the Building Code and those materials and types of construction specified in Section A107. 2. Connections. Materials and connectors used for the interconnection of parts and portions of the structure shall conform to the Building Code. Nails may be used as a part of an approved connector. 3. Unreinforced masonry walls. In addition to the seismic forces required by this chapter, unreinforced masonry walls shall be analyzed as specified in the 1985 Uniform Building Code to withstand all vertical loads as specified in the Building Code. Such walls shall meet the minimum requirements set forth in the Building Code. Exception: When calculating shear or diagonal tension stresses due to seismic forces, existing masonry shear walls may be designed to resist 1.0 times the required forces in lieu of the 1.5 factor required by the Building Code. No allowable tension stress will be permitted in unreinforced masonry walls. Walls not capable of resisting the required design forces specified in this chapter shall be strengthened or shall be removed and replaced. 11 Exceptions: 1. Unreinforced masonry walls may be analyzed in accordance with Section A107. 2. Unreinforced masonry walls which carry no design loads other than their own weight may be considered veneer if they are adequately anchored to new supporting elements. Substantial changes in wall thickness or stiffness shall be considered in the analysis for out -of -plane and in -plane wall stability, and the wall shall be restrained against out -of -plane instability by anchorage and bracing to the roof or floor diaphragm in accordance with Section A106(d). Exception: Variations in wall stiffness caused by nominal openings such as windows and doors need not be considered. (h) Combination of Vertical and Seismic Forces. 1. New materials. All new materials introduced into the structure to meet the requirements of this section which are subject to combined vertical and horizontal forces shall comply with the Building Code. 2. Existing materials. When stress in existing lateral force resisting elements are due to a combination of dead loads plus live loads plus seismic loads, the allowable working stress specified in the Building Code may be increased 100 percent. However, no increase will be permitted in the stresses allowed in Section A107. The stresses in members due to only seismic and dead loads shall not exceed the values permitted by the Building Code. 3. Allowable reduction of bending stress by vertical load. Calculated tensile fiber stress may be reduced by the full direct stress due to vertical dead loads. MATERIALS OF CONSTRUCTION Sec. A107. (a) General. All materials permitted by this code, including their appropriate allowable stresses and those existing configurations of materials specified herein, may be utilized to meet the requirements of this chapter. (b) Existing Materials. 1. Unreinforced masonry walls. Unreinforced masonry walls analyzed in accordance with this chapter may provide vertical support for roof and floor construction and resistance to lateral loads. All units of both bearing and non - bearing walls shall be laid with full shoved mortar joints; all head, bed and wall (collar) joints shall be solidly filled with mortar; and the bonding of adjacent wythes of multi -wythe walls shall be as follows: The facing and backing shall be bonded so that no less than 4 percent of the wall surface of each face is composed of headers extending not less than four inches into the backing. The distance between adjacent full - length headers shall not exceed 24 inches IN either vertically or horizontally. In walls where a single header does not extend through the wall, headers from the opposite sides shall overlap at least four inches, or headers from opposite sides shall be covered with another header course overlapping the header below at least four inches. Wythes of walls not bonded as described above shall be considered as veneer. The veneer wythe shall not be included in the effective thickness used to calculate the height -to- thickness ratio and the shear capacity of the wall. Tension stresses due to seismic forces normal to the wall may be neglected if the wall does not exceed the height -to- thickness ratio set forth in Table Al -F and the in -plane shear stresses due to seismic loads set forth in Table AM. If the wall height -to- thickness ratio exceeds the specified limit, the wall may be supported by vertical bracing members designed to satisfy the requirements of the 1985 Uniform Building Code. The deflection of such bracing members at design loads shall not exceed one -tenth of the wall thickness. Exception: The wall may be supported by flexible bracing members designed in accordance with Section A106(b) of this chapter if the deflection at design loads is not less than one - quarter nor more than one -third of the wall thickness at the level under consideration. All vertical bracing members shall be attached to floor and roof construction for their design loads independently of required wall anchors. Horizontal spacing of vertical bracing members shall not exceed one -half the unsupported height of the wall nor ten feet, whichever is less. The wall height may be measured vertically to bracing elements other than a floor or roof. Spacing of elements and wall anchors shall not exceed six feet. Bracing elements shall be detailed to minimize the horizontal displacement of the wall components of vertical displacements of the floor or roof. 2. Veneer. Veneer shall be anchored with approved anchor ties conforming to the required design capacity specified in Section 3304(c) of the 1985 Uniform Building Code, and placed at a maximum spacing of 24 inches. Exception: Existing veneer anchor ties may be acceptable provided the ties are in good condition and conform to the minimum size, maximum spacing and material requirements as indicated below. The veneer anchor ties shall be corrugated galvanized iron strips not less than one inch in width, eight inches in length and one - sixteenth of an inch in thickness and shall be located and laid in every alternate course in the vertical height of the wall at a spacing not to exceed 17 inches on center horizontally. As an alternate, the spacing may be every fourth course vertically at a spacing not to exceed nine inches on center horizontally. 13 The existence and condition of existing veneer anchor ties shall be verified as follows: (a) An approved testing laboratory shall verify the location and spacing of the ties and shall submit a report to the Director of Inspection Services for approval as a part of the structural analysis. (b) The veneer in a selected area shall be removed to expose a representative sample of ties (not less than four) for inspection by the Director of Building Services. 3. Existing roof, floors, walls, footings, and wood framing. Existing materials, including wood shear walls, may be used as a part of the lateral load resisting system, provided that stresses in these materials do not exceed the values shown in Table No. Al -G. (c) Strengthening of Existing Materials. New materials, including wood shear walls may be utilized to strengthen portions of the existing seismic resisting system provided that stresses do not exceed the values shown in Table No. Al -H. (d) Minimum Acceptable Quality of Existing Unreinforced Masonry Walls. 1. General provisions. All unreinforced masonry walls utilized to carry vertical loads and seismic forces parallel and perpendicular to the wall plane shall be tested as specified in this subsection. All masonry quality shall equal or exceed the minimum standards established herein or shall be removed and replaced by new materials. The quality of mortar in all masonry walls shall be determined by performing in -place shear tests. Alternate testing methods may be approved by the Director of Building Services upon submission of adequate evidence to indicate its equivalence. The vertical wall joint between wythes (collar joint) shall be inspected at each test location after the in -place shear tests, and an estimate of the percentage of wythe to wythe mortar coverage shall be reported along with the results of the in -place shear tests. Where the exterior face is veneer, the type of veneer its thickness and its bonding and /or ties to the structural wall masonry shall also be reported. Nothing shall prevent the pointing with mortar of all the masonry wall joints before the tests are first made. Prior to any pointing, the mortar joints must be raked and cleaned to remove loose and deteriorated mortar. Mortar for pointing shall be Type S or N, except masonry cements shall not be used. All preparation and mortar pointing shall be done under the continuous inspection of a special inspector. At the conclusion of the inspection, the inspector shall submit a written report to the person responsible for the seismic analysis of the building setting forth the results of the work inspected. Such report shall be submitted to the Director of Building Services for approval as part of the structural analysis. All testing shall be performed in accordance with the requirements specified in this section by an approved agency. An accurate record of all such tests and their location in the building shall be recorded and these results shall be submitted to the Director of Building Services for approval as part of the structural analysis. 2. Number and location of tests. The minimum number of tests shall be as follows. At each of both the first and top stories, not less than two per wall line or line of wall elements providing a common line of resistance to lateral forces. At each of all other 14 stories, not less than one per wall elements providing a common line of resistance to lateral forces. In any case, not less than one per 1500 square feet of wall surface and a total of eight. The shear tests shall be taken at locations representative of the mortar conditions throughout the entire building, taking into account variations in workmanship at different building height levels, variations in weathering of the exterior surfaces, and variations in the condition of the interior surfaces due to deterioration caused by leaks and condensation of water and /or by the deleterious effects of other substances contained within the building. Where the higher h/t ratios allowed in footnotes 4 and 5 of Table Al -F are to be utilized, all the in -place shear tests taken at the top story shall be included in the 80 percent of the shear tests used to determine the minimum mortar shear strength. The exact test locations shall be determined at the building site by the person responsible for the seismic analysis of the subject building. 3. In -place shear tests. The bed joint of the outer wythe of the masonry wall shall be tested in shear by laterally displacing a single brick relative to the adjacent bricks in the wythe. The opposite head joint of the brick to be tested shall be removed and cleaned prior to testing. The minimum quality mortar in 80 percent of the shear tests shall not be less than the total of 30 psi plus the axial stress in the wall at the point of the test. The shear stress shall be based on the gross area of both bed joints and shall be that at which movement of the brick is first observed. (e) Testing Shear Bolts. One - fourth of all new shear bolts and dowels embedded in unreinforced masonry walls shall be tested by a special inspector using a torque calibrated wrench to the following minimum torques: 1/2 -inch diameter bolts or dowels = 40 foot - pounds 5/8 -inch diameter bolts or dowels = 50 foot- pounds 3/4 -inch diameter bolts or dowels = 60 foot - pounds No bolts exceeding 3/4 -inch diameter shall be used. All nuts shall be installed over malleable iron or plate washers when bearing on wood and heavy cut washers when bearing on steel. (f) Determination of Allowable Stresses for Design Methods Based on Test Results. 1. Design shear values. Design seismic in -plane shear stresses shall be substantiated by tests performed as specified in Item No. 3 of Subsection (d). Design stresses shall be related to test results obtained in accordance with Table No. Al -I. Intermediate values between 5 and 10 psi may be interpolated. 2. Design compression and tension values. Compression stresses for unreinforced masonry having a minimum design shear value of 3 psi shall not exceed 100 psi. Design tension values for unreinforced masonry shall not be permitted. (g) Existing Wall Anchors. Five percent of the existing wall anchors utilized as all or part of the required wall anchors shall be tested in pullout by an approved testing 15 agency. The minimum number tested shall be four per floor, with two tests at walls with joist parallel to the wall. The test apparatus shall be supported on the masonry wall at a minimum distance equal to the wall thickness from the anchor tested. The rod anchor shall be given a preload of 300 pounds prior to establishing a datum for recording elongation. The tension test load reported shall be recorded at 1/8 -inch relative movement of the anchor and the adjacent masonry surface. Results of all tests shall be reported. The report shall include the test results as related to the wall thickness and joist orientation. The allowable resistance value of the existing anchors shall be forty percent of the average of those tested anchors having the same wall thickness and joist orientation. (h) Qualification Tests. Qualifications tests for new devices used for wall anchorage shall be tested with the entire tension load carried on the enlarged head at the exterior face of the wall. Bond on the part of the device between enlarged head and the interior wall face shall be eliminated for the qualification tests. The resistance value assigned the device shall be twenty percent of the average of the ultimate loads. INFORMATION REQUIRED ON PLANS Sec. A108. (a) General. In addition to the seismic analysis required in this chapter the person responsible for the seismic analysis of the building shall determine and record the information required by this section on the approved plans. (b) Construction Details. The following requirements with appropriate construction details shall be made a part of the approved plans. 1. All unreinforced masonry walls shall be anchored at the roof and ceiling levels by tension bolts through the wall as specified in Table Al -H, or by an approved equivalent at a maximum anchor spacing of six feet. All unreinforced masonry walls shall be anchored at all floors and ceiling with tension bolts through the wall or by existing rod anchors at a maximum anchor spacing of six feet. All existing rod anchors shall be secured to the joists to develop the required forces. Tests conforming to this chapter will be required to verify the adequacy of the embedded ends of existing rod anchors. Exception: Walls need not be anchored to ceiling systems that, because of their low mass and or relative location with respect to the floor or roof systems, would not impose significant normal forces on the wall and cause out -of -plane wall failure. Calculations and drawings to verify this exception must be submitted as part of the analysis. At the roof and all floor levels, the anchors nearest the building corners shall be combination shear and tension anchors located not more than two feet horizontally from the inside corners of the walls. 16 When access to the exterior face of the masonry wall is prevented by proximity of an existing building, wall anchors conforming to Items 5 (a) or (b) in Table No. Al -H may be used. Alternative devices to be used in lieu of tension bolts for masonry wall anchorage shall be tested as specified in Section A107(h). 2. Diaphragm chord stresses of horizontal diaphragms shall be developed in existing materials or by the addition of new materials. 3. Where trusses and beams other than rafters or joists are supported on masonry independent secondary columns shall be installed to support vertical loads. 4. Parapets and exterior wall appendages not capable of resisting the forces specified in this chapter shall be removed, stabilized, or braced to ensure that the parapets and appendages remain in their original position. The maximum height of an unbraced, unreinforced masonry parapet above the lower of either the level of tension anchors or roof sheathing, shall not exceed one and one -half times the thickness of the parapet wall. If the required parapet height exceeds this maximum height a bracing system designed for the force factors specified in the Table 23 -J of the 1985 Uniform Building Code shall support the top of the parapet. Parapet corrective work must be performed in conjunction with the installation of tension roof anchors. The minimum height of a parapet above the wall anchor shall be 12 inches. Exception: If a reinforced concrete beam is provided at the top of the wall, the minimum height above the wall anchor may be six inches. 5. All deteriorated mortar joints in unreinforced masonry walls shall be pointed with Type S or N mortar. Prior to any pointing, the wall surface must be raked and cleaned to remove loose and deteriorated mortar. All preparation and pointing shall be done under the continuous inspection of a special inspector. At the conclusion of the project, the inspector shall submit a written report to the Director of Building Services setting forth the portion of work inspected. 6. Repair details for any cracked or damaged unreinforced masonry wall required to resist forces specified in this chapter. (c) Existing Construction. The following existing construction information shall be made part of the approved plans: 1. The type and dimensions of existing walls and the size and spacing of floor and roof members. 2. The extent and type of existing wall anchorage to floors and roof. 17 3. The extent and type of any parapet bracing or other structural reinforcement to parts or portions of the building which were previously performed. 4. Accurately dimensioned floor plans and masonry wall elevations showing dimensioned opening, piers, wall thickness and heights, veneer locations and existing anchorages. 5. The locations of cracks or other damaged portions of unreinforced masonry walls requiring repair. 6. The type of interior wall surfaces and ceilings, and if reinstalling or anchoring of existing plaster is necessary. 7. The general condition of the mortar joints and if the joints need repointing. 8. The location of all in -place shear tests or core tests, shall be shown on the floor plans and building wall elevations. Design Check for Compatibility of Roof Diaphragm Stiffness to Unreinforced Masonry Wall Out -of -Plane Stability. Sec. A109 (a) General. The requirements of this section are in addition to the other analysis requirements of this Chapter. The relative stiffness and strength of a diaphragm governs the amount of amplification of the seismic ground motion by the diaphragm. and therefore, a diaphragm stiffness and strength related check of the out -of plane stability of unreinforced masonry walls anchored to wood diaphragms shall be made. This section contains a procedure for evaluation of the out -of -plane stability of unreinforced masonry walls anchored to wood diaphragms that are coupled to shear resisting elements. (b) Definitions. The following definitions are applicable to this section. Cross Wall. A wood framed wall having a height to length ratio complying with Section 4713(d) or table 25 -I of the 1985 Uniform Building Code and sheathed with any of the materials described in Table Al -J or Table Al -K. The total strength of all cross walls located within any 40 feet length of diaphragm measured in the direction of the diaphragm span shall not be less than 30 percent of the strength of the diaphragm in the direction of consideration. Demand Capacity Ratio (DCR). A ratio of the following: 1. Demand equals the lateral forces due to 33 percent of the combined weight of the diaphragm and the tributary weight of the walls and other elements anchored to the diaphragm. WO 2. Capacity equals the diaphragm total shear strength in the direction under consideration as determined using the values in Tables No. Al -J or Table Al -K. (C) Notations. D = depth of diaphragm in feet, measured perpendicular to the diaphragm span. h/t = height -to- thickness of an unreinforced masonry wall. The height shall be measured between wall anchorage levels and the thickness shall be measured through the wall cross section at the level under consideration. L = span of diaphragm between masonry shear walls or steel frames. Vc = total shear capacity of cross walls in the direction of analysis immediately below the diaphragm level being investigated as determined by using Tables No. Al -J and Al -K. VU = maximum shear strength in pounds per foot for a diaphragm sheathed with any of the materials given in tables No. Al -J and Al -K. Wd = total dead load of the diaphragm plus the tributary weight of the walls anchored to the diaphragm, the tributary ceiling and partitions and weight of any other permanent building elements at the diaphragm level under consideration. (d) Design Check Procedure. 1. General. The demand - capacity ratio (DCR) for the building shall be calculated using the following equations: DCR = 0.33 Wd / 2 vu D For building without cross walls or DCR = 0.33 Wd /2 vu D + Vc for building with cross walls 2. Diaphragm Deflection. The calculated DCR shall be to the left of the curve in Figure No. Al -L. Where the calculated DCR is outside (to the right of) the curve, the diaphragm deflection limits are exceeded and cross walls may be used to reduce the deflection. 3. Unreinforced Masonry Wall Out -of -Plane Stability. The DCR shall be calculated discounting any cross wall. If the DCR from this method corresponding to the diaphragm span is to the right of the curve in Figure No. Al -L, the region within the curve at and below the intersection of the diaphragm span with the curve may be used to determine the allowable h/t values per Table No. Al -F. 19 TABLE NO AI -F ALLOWABLE VALUE OF HEIGHT - THICKNESS (h /t) RATIO OF UNREINFORCED MASONRY WALLS WITH MINIMUM QUALITY MORTAR BUILDING WITH ALL OTHER COMPLYING CROSS WALLS BUILDINGS One Story Building Walls 13 -16 234 13 First Story of Multi -Story Buildings 16 15 Walls in the Top Story of Multi -Story Buildings 9-14 234 9 All Other Walls 16 13 Minimum mortar quality shall be determined by laboratory testing in accordance with this chapter. 2 The minimum mortar shear strengths required in the following footnotes 4 and 5 shall be that shear strength without the effect of axial stress in the wall at the point of the test. 3 The larger height -to- thickness ratio may be used where mortar shear tests in accordance with Section A107(d) establish a minimum mortar shear strength of not less than 100 psi or where the tested mortar shear strength is not less than 60 psi and a visual examination of the vertical wythe -to -wythe wall joint (collar joint) indicates not less than 50 percent mortar coverage. 4 Where a visual examination of the collar joint indicates not less than 50 percent mortar coverage and the minimum mortar shear strength when established in accordance with Section A107(d) is greater than 30 psi but less than 60 psi, the allowable height -to- thickness ratio may be determined by linear interpolation between the larger and smaller ratio values in direct Proportion to the mortar shear strength. 20 TABLE NO. Al -G VALUES FOR EXISTING MATERIALS 1 1. Horizontal Diaphragms a. Roofs with straight sheathing with the roof covering applied directly to 100 PLF for seismic shear. the sheathing. b. Roofs with diagonal sheathing with the roof covering applied directly to 400 PLF for seismic shear. the sheathing. c. Floors with straight tongue and groove sheathing. 150 PLF for seismic shear. d. Floors with straight sheathing and finished wood flooring. e. Floors with diagonal sheathing and finished wood flooring. f. Floors or roofs with straight sheathing and plaster applied to the joists or rafters. 300 PLF for seismic shear. 450 PLF for seismic shear. Add 50 PLF to the allowable values in items 1a and 1c. 2. Cross Walls Wood stud walls with lath and plaster. 3. Plain Concrete Footings 100 PLF for each side for seismic shear. f c = 1500 psi unless a otherwise shown by tests. 4. Douglas Fir Wood 5. Reinforcing Steel 6. Structural Steel Same as 1985 UBC values for No. Douglas Fir 3 f c = 18,000 psi maximum. f c = 20,000 psi maximum. ------------------------------------------------------------------------------------------------------------------------- 1 Materials must be sound and in good condition. 2 Wood lath and plaster must be reattached to existing joists or rafters in a manner approved by the Director of Building Services. 3 Stresses given may be increased for combinations of loads as specified in Section A106. 21 TABLE NO. Al -H ALLOWABLE VALUES FOR NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION New Materials or Configuration of Materials ........................................................... 1. Horizontal Diaphragms Plywood sheathing applied directly over existing straight sheathing with ends of plywood sheets bearing on joists or rafters and edges of plywood located on center of individual sheathing boards. 2. Cross Walls Plywood sheathing applied directly over existing wood studs. (No value shall be given to plywood applied over existing plaster or wood sheathing boards). Allowable Values Same as specified in Table 25 -J of the 1985 Uniform Building Code for blocked diaphragms. Same as values specified in Table No. 25- K of the 1985 UBC for shear walls. b. Dry wall or plaster applied directly over existing wood studs. c. Dry wall or plaster applied to plywood sheathing over wood studs 3. Shear Bolts Shear bolts and shear dowels embedded a minimum of 8 inches into unreinforced masonry walls. Bolt centered in a 2 -1/2 inch diameter hole with dry -pack or non- shrink grout around the circumference of the bolt. 13 75 percent of the values specified in Table No. 47 -I of the 1985 UBC One -third of the values specified in Table No. 47 -I of the 1985 UBC 133 percent of the values for plan masonry specified in Table No. 24 -J of the 1985 UBC. No values larger than those given for 3/4 inch diameter bolts shall be used. 4. Tension Bolts Tension bolts and tension dowels extending 1200 pounds per bolt. entirely through URM walls secured with bearing plates on far side of wall with at least 30 square inches of area. 2 5. Combination Shear and Tension Wall Anchors (a) Bolts extending to the exterior face of the wall with a 2 -1/2 inch round plate under the head. Install as specified for shear bolts. Spaced not closer than 12 inches on centers. 123 600 lbs. per bolt for tension see Item 3 (Shear Bolts) for shear values. Fla [5. Combination Shear and Tension Wall Anchors Continued] (b) Bolts or dowels extending to the exterior face of the wall with a 2 -1/2 inch round plate under the head and drill at an angle of 22 -1/2 degrees to the horizontal. Install as specified for shear bolts. 123 1200 lbs. per bolt or dowel for tension See Item 3 for shear values (c) Through bolt with bearing plate for tension per Item 4. Combined with minimum 8 inch grouted section for shear per Item 3. 7. Infilled Walls Reinforced masonry infilled openings in existing unreinforced masonry walls with keys or dowels to match reinforcing. 8. Reinforced Masonry Masonry piers and walls reinforced as specified in Chapter 24 of the 1985 Uniform Building Code. 9. Reinforced Concrete Concrete footings, walls and piers reinforced as specified in Chapter 26 and designed for tributary loads. 10. Existing Foundation Loads Foundation loads for structures exhibiting no evidence of settlement. See Item 4 (Tension Bolts) for tension values See Item 3 for shear values. Same as values specified for unreinforced masonry walls in this chapter. Same as values specified in Table No. 24- B of the 1985 Uniform Building Code. Same as values specified in Chapter 26 of the 1985 Uniform Building Code. Calculated existing foundation loads due to maximum dead load plus live load may be increased by 25 percent and may be increased 50 percent for dead load plus seismic loads required by this chapter. -------------------------------------------------------------------------------------------------------------------------- 1 Bolts and dowels to be treated as specified in Section A107. 2 Bolts and dowels to be 1/2 -inch diameter minimum. 3 Drilling for bolts and dowels shall be done with an electric rotary drill. Impact tools shall not be used for drilling holes or tightening anchor and shear bolt nuts. 4 Allowable bolt and dowel values specified are for installations in minimum three wythe wall. For installations in two wythe walls use 50 percent of the value specified, except that no value shall be given to tension bolts that do not extend entirely through the wall and are secured with bearing plates on the far side. 23 TABLE NO. Al -1 ALLOWABLE SHEAR STRESS FOR TESTED UNREINFORCED MASONRY WALLS SHEAR TESTS Eighty percent of Average test results. Seismic in-plane test results in psi of cores in psi shear in psi based not less than: on gross area* 30 plus axial stress 20 3 40 plus axial stress 27 4 50 plus axial stress 33 5 100 plus axial stress 67 or more 10 (maximum) or more 4 Allowable shear stress may be increased by addition of 10 percent of the axial stress due to the weight of the wall directly above. 24 TABLE NO. AW ALLOWABLE VALUES FOR EXISTING MATERIALS TO BE USED ONLY IN THE COMPUTATION OF THE DEMAND CAPACITY RATIO DESIGN CHECK Existing Materials or Configuration of Materials 1 ---------------------------------------- 1. Horizontal Diaphragms Allowable Values a. Roofs with straight sheathing and roofing applied directly to the sheathing. b. Roofs with diagonal sheathing and roofing applied directly to the sheathing. 2. Cross Walls 2 a. Plaster on wood or metal lath. b. Plaster on gypsum lath. c. Gypsum wall board unblocked edges. d. Gypsum wall board blocked edges 100 lbs. per foot for seismic shear. 250 lbs. per foot for seismic shear. Per side: 200 lbs. per foot for seismic shear. 175 lbs. per foot for seismic shear. 75 lbs. per foot for seismic shear. 125 lbs. per foot for seismic shear. ----------------------------------------------------------------------- Materials must be sound and in good condition. 2 For cross walls, values of all materials may be combined, except the total combined value shall not exceed 300 lbs. per foot for seismic shear. 25 TABLE NO. Al -K ALLOWABLE VALUES FOR NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION MATERIALS TO BE USED ONLY IN THE COMPUTATION OF THE DEMAND CAPACITY RATIO DESIGN CHECK New Materials or Configuration of New and Existing Materials Allowable Values 1. Horizontal Diaphragms a. Plywood sheathing applied directly over existing straight sheathing with ends of plywood sheets bearing on rafters and edges of plywood located on the center of individual sheathing boards. 225 lbs. per foot for seismic shear. 2. Cross Walls 2 a. Plywood sheathing applied directly over existing wood studs. No value 1.33 times the values specified in Table 25- shall be given to plywood applied K of the 1985 UBC over existing plaster or wood sheathing. b. Drywall or plaster applied directly 100 percent of the values specified in over existing wood studs. Table 47 -I of the 1985 UBC ---------------------------------------------------------------------------------------------------------------------- Materials must be sound and in good condition. 2 For cross walls, values of all materials may be combined, except the total combined shear value shall not exceed 300 lbs. per foot for seismic shear. Section 7.09.025 - Reconstruction of Unreinforced Chimneys Unreinforced chimneys shall be reconstructed in accordance with the seismic safety standrds set forth in Chapter 37 of the currently adopted edition of the Uniform Building Code and be done to the satisfaction of the Director of Building Services. Section 7.09.030 - Modifications to Reinforced Masonry. Woodframe and Other Structures The repair, reconstruction or restoration of reinforced masonry structures, woodframe structures and other types of structures shall be made in accordance with seventy -five percent (75 %) of the current Uniform Building Code Value for lateral forces to the satisfaction of the Planning Director and the Director of Building Services. 26 Section 7.09.035 - Mitigation Measures Phase 1: Owners of unreinforced masonry buildings shall provide complete plans and calculations for seismic upgrades by March 1, 1991. Phase 2: Owners of unreinforced masonry buildings shall complete all work related to seismic upgrades by May 1, 1993. SECTION XV Article IX of Chapter 7 of the Town code is hereby repealed in its entirety. SECTION XVI This ordinance takes effect 30 days after it is adopted. Within 15 days after this ordinance is adopted the Town Clerk shall cause it to be published once in a newspaper of general circulation published and circulated in the Town. This ordinance was introduced at a regular meeting of the Town Council of the Town of Los Gatos on the 6th day of May, 1991 and adopted by the following vote as an ordinance of the Town of Los Gatos at a regular meeting of the Town Council of the Town of Los Gatos on the 20th day of May, 1991. COUNCIL MEMBERS: AYES: Randy Attaway, Joanne Benjamin Steven Blanton, Eric D. Carlson, Mayor Brent N. Ventura NAYS: None ABSENT: None ABSTAIN: None SIGNED: MAYOR OF THE TOWN OF LOS GATOS LOS GATOS, CALIFORNIA ATTEST: CLERK OF THE TOWN OI - OS GATOS LOS GATOS, CALIFORNIA c1k:d7: \other \b1dgcode 27