Loading...
2011060610 - Attachment 01 and 02 - 16005 Los Gatos BoulevardDATE: SUBJECT: NOTICE OF MITIGATED NEGATIVE DECLARATION TOWN OF LOS GATOS 110 E. MAIN STREET LOS GATOS, CA 95032 (408) 354-6872 December 10, 2010 AN INITIAL STUDY AND NEGATIVE DECLARATION HAVE BEEN PREPARED BY THE TOWN OF LOS GATOS AND ARE ON FILE IN THE COMMUNITY DEVELOPMENT DEPARTMENT AT 110 E. MAIN ST. PROJECT LOCATION: 16005 LOS GATOS BLVD & 625 BLOSSOM HILL RD PROJECT DESCRIPTION: Planned Development Application PD-07-145 Requesting approval to rezone the project site from CH to CH:PD, to demolish the existing auto dealership buildings, construct a mixed use development consisting of retail commercial space, senior apartments, and single-family residences. No significant environmental impacts have been identified as a result of this project, and a Mitigated Negative Declaration is recommended. APN 529-16-025 & 529-16-053. The Initial Study and Mitigated Negative Declaration are available in the Community Development Department of Town Hall at the above address for review. The public comment period for this proposed Mitigated Negative Declaration is 20 days from the receipt of this notice and will expire on January 10, 2011. Written comments should be submitted to the Community Development Department. A public hearing on this matter is tentatively scheduled for January 12, 2011 at 7:00 PM in the Town Council Chambers at 110 E. Main Street. If you have any questions in this matter please contact Heather Bradley at (408) 354-6806. ATTACHMENT: Recommended Mitigated Negative Declaration and Initial Study DISTRIBUTION: Town Manager Town Attorney Director of Community Development Town Engineer Town Library County Clerk Planning Commission (7 copies) Santa Clara County Clerk Recorders Office (1 original + 3 copies) Los Gatos Union School District Los Gatos Saratoga Union High School District Bay Area Air Quality Management District PG&E San Jose Water Company ATTACHMENT 1 Association of Bay Area Governments Santa Clara County Fire Department West Valley Sanitation District South Bay Cablevision Verizon Valerie Geier (Notice only) Carpenters Union (Notice only) Kenneth Rodriguez & Partners CHL Ventures, LP N:\DEV\HEATHER B\16005 Los Gatos Blvd\Environmental\Legals\LGB 16005MNDnotice.doc NOTICE Town of Los Gatos Environmental Impact Review Mitigated Negative Declaration Lead Agency: Town of Los Gatos Community Development Department 110 East Main Street Los Gatos, CA 95031 Project Title and Location: 16005 Los Gatos Boulevard and 625 Blossom Hill Road Planned Development Application PD-07-145 Project Description: The project applicant is requesting approval to do the following on the +4.5-acre site (APN 529-16-025 and 529-16-053): • Rezone the project site from CH to CH:PD • Demolish existing auto dealership buildings • Construct 23,267 square feet (s.f.) of retail commercial space • Construct six senior apartments above the retail commercial space • Develop 29 single-family residences A breakdown of land use by area would be as follows: Areal Extent (Square Feet) Building Landscaping and Parking and Proposed Use Coverage Patio Driveways Commercial (23,267 s.f.) and Senior Housing 23,267 28,405 37,503 (6 Units, 8,628 s.f.) on 2.0 Acres Residential Landscaping and Parking and Lot Area Open Space Driveways Single -Family Residences (29) on 2.4 Acres 35,612 47,588 20,723 The eastern half of the site (2.0 acres) would be developed with 23,267 s.f. of retail commercial space in two structures. A one-story, retail commercial building (14,216 s.f.) would be located at the southeast corner of the site (adjacent to Los Gatos Boulevard and Blossom Hill Road). Retail commercial space (9,051 s.f.) would also be provided on the first floor of a two-story, mixed -use building proposed in the northeast corner of the site (adjacent to Los Gatos Boulevard and Placer Oaks Road). Proposed commercial uses are expected to include a sit-down restaurant/cafe and retail commercial space. The one- story building would have a maximum height of 25.5 feet from existing grade, while the two-story commercial building would have a maximum height of 35 feet from existing grade. There are two patios proposed on the west side of both commercial buildings, away from both Los Gatos Boulevard and Blossom Hill Road. JUNE, 2010 1 MITIGATED NEGATIVE DECLARATION — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD The second floor of the mixed -use building would be developed with six senior apartments (8,628 s.f.), which would all be designated as Below Market Rate units. Senior residential units would be one- and two -bedroom apartments with one bath. All senior apartments would be age -restricted and for rent. The western half of the site (2.4 acres) would be developed with 29 residential lots. Typical lot size is proposed to be 2,450 s.f. Single-family homes would be constructed on all 29 lots, ranging in size from 2,003 to 2,684 s.f. All residences would be two stories (typically three to five bedrooms, two to three baths) with garage and storage on the ground floor, living and bedrooms on the second floor, and bedroom/bath on the optional third floor loft. The proposed site plan is included as Attachment 1. Access to the two commercial buildings would be provided by three driveways, one located on each adjacent street: Los Gatos Boulevard, Blossom Hill Road, and Placer Oaks Road. These three driveways would be connected on -site by the proposed parking lot west of the commercial buildings. There is one driveway on Placer Oaks Road that would provide direct access to the residential lots. A second driveway would connect the southern part of the residential area to the commercial area parking lot adjoining Blossom Hill Road. The driveway that intersects with the Blossom Hill Road driveway would provide direct access to the commercial parking lot as well as the southerly residential driveway. With the interconnection of the residential and commercial uses on the project site, project residents could also use the site's commercial driveways on Los Gatos Boulevard and Placer Oaks Road to access the residential development. The two residential driveways would be connected by one internal street, Street `C'. Street `C' would range in width from 20 to 25 feet, and the two smaller internal streets, Streets 'A' and 'B' would be 20 feet wide. A total of 184 parking spaces would be provided. On the eastern portion of the site where commercial uses are proposed, 104 parking spaces would be provided for retail commercial uses (4.5 spaces per 1,000 s.f.) and six spaces would be provided for senior housing (one space per unit). On the western portion of the site where residential uses are proposed, 58 covered parking spaces would be provided as two enclosed garage spaces in each unit and 16 guest spaces. The commercial parking lot would be separated from residential parking spaces. Project plans also include the installation of landscaping throughout the site as well as pedestrian walkways and hardscape improvements. Landscaping on private lots and common open space in the residential portion of the site would comprise approximately 46 percent of the residential site (47,588 s.f.), while landscaping and patio areas in the commercial portion of the site would cover approximately 32 percent of the commercial site (28,405 s.f.). Overall, landscaping, open space, and patio areas would cover approximately 39 percent of the site (75,993 s.f.). A pedestrian corridor would connect the residential portion of the project to the proposed commercial uses. The decorative walkway would include curved seat walls and a gated entry. Determination: Although the proposed project could have a significant effect on the environment, there will not be a significant effect in this case because the mitigation measures listed below have been added to the project, mitigating potential impacts to a less -than -significant level. An Environmental Impact Report will not be required. Statement of Reasons to Support Finding: 1. Aesthetics: Existing views of the project site consist of single -story commercial buildings previously serving an auto dealership as well as vehicle service facilities. The site also contains extensive parking areas for vehicle display and storage along Los Gatos Boulevard and Blossom Hill Road. Currently, DECEMBER, 2010 2 MITIGATED NEGATIVE DECLARATION — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD screened chain link fencing obstructs potential views to the center of the site from Placer Oaks Road and Blossom Hill Road. Commercial Development. From Los Gatos Boulevard, the two commercial buildings of the proposed project would be one and two stories high, with a maximum height of approximately 35 feet at the roof peak. Building One would be a two-story structure providing retail uses on the first floor and six senior apartments on the second level. This building would have a maximum height of 35 feet and would be similar in height and bulk to a nearby commercial building on the northwest corner of the Los Gatos Boulevard and Placer Oaks Road intersection. However, the architectural style of Building One would differ from that of the existing commercial structure across Placer Oaks Road. In addition, the proposed building's setback from Los Gatos Boulevard would be slightly less than the adjoining commercial building, 25 feet rather than approximately 30 feet, respectively (including sidewalk in the public right- of-way). Building Two would be a single -story building with a maximum height of 25.5 feet, situated on the southeastern portion of the project site. Building Two would be separated from Building One by the main driveway entrance to the commercial facilities' parking lot, behind both of the commercial structures. Building Two's single -story design would be similar to the single -story Blossom Hill Pavilion commercial complex that is located opposite the project site on the southwest corner of the Los Gatos Boulevard and Blossom Hill Road intersection. The project's site design proposes Building Two setbacks from Los Gatos Boulevard similar to those of Blossom Hill Pavilion. The proposed commercial buildings' single -story and two-story elements would be similar to the retail commercial and office buildings to the north and south of the project site along Los Gatos Boulevard. The proposed project's design would contrast with the Cornerstone and King's Court shopping centers on the east side of Los Gatos Boulevard on either side of Blossom Hill Road. These retail centers consist of single -story commercial buildings with parking facilities located along Los Gatos Boulevard and commercial buildings situated to the rear of the properties, relative to Los Gatos Boulevard. Presently, there are views to the Santa Cruz Mountains for pedestrians and motorists traveling southbound along Los Gatos Boulevard and in both directions on Blossom Hill Road. Views of mountain ridgelines from Blossom Hill Road would be to the south and, due to the project site's northerly location, would remain as currently available. Ridgeline views from Los Gatos Boulevard in the project vicinity are generally blocked and filtered by the project site's existing buildings and the Blossom Hill Pavilion structure, respectively. Residential Development. The residential component of the proposed project entails the development of 29 single-family units on the western portion of the project site. Lots 1 through 5 would front the north side of Blossom Hill Road, while Lots 15 through 19 would front along the south side of Placer Oaks Road. The proposed residential units would be two stories in height along the street front. The residential units proposed within the project site could be developed as two-story homes with an option for a third story loft. Access to all garages would be from internal driveways on the project site. Typical front elevations for the units would be 30 feet from existing grade. The proposed two-story units would be consistent with residential development adjoining the project site to the west. Two-story single-family residences (condominiums) adjoin the project site to the northwest on Placer Oaks Road; these residences are part of a residential development that is addressed on Oak Rim Way. An access drive and parking facilities, including uncovered and carport parking spaces, for this residential development immediately adjoin the northwestern perimeter of the project site. Although a DECEMBER, 2010 3 MITIGATED NEGATIVE DECLARATION— 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD masonry wall separates the two properties, the upper stories of the residences proposed on Lots 9 through 14 would overlook the access driveway and parking facilities of the residential development to the west. Similar to the northwestern portion of the project site, two-story single-family residential units are proposed for the southwestern corner of the site. The Valley Oaks Apartments adjoin the subject property to the west along Blossom Hill Road. The apartment buildings are also two-story structures with residents' access along the western property boundary. A portion of the access drive and the carport structure for the Valley Oaks Apartments adjoin the project site near the central western property line. The project plans specify development of residential Lots 1 through 6 in the southwestern corner of the project site. Of these lots, only Lots 5 and 6 would be in proximity to the Valley Oaks property. These two lots are set back from the common property line and separated from the apartment buildings by a proposed driveway and three parking spaces, common open space, and the Lot 5 side yard on the project site. Unlike the northwestern corner of the project site, existing landscaping, including a mature redwood and brush cherry trees, provide substantial screening between the two properties. Most of these trees would be retained in place to preserve the effective screening provided by this landscaping; the proposed landscaping plans would supplement existing landscaping with additional plantings. The development of residential Lots 1 through 5 and Building Two would change the views of the project site from Blossom Hill Road. Current views from this vantage include the walls of existing service buildings, screened fencing of the center site, and expansive parking lots. The five residential units proposed for this part of project site would extend the residential character established by the Valley Oaks Apartments along the north side of Blossom Hill Road from Oak Rim Way close to the Los Gatos Boulevard intersection. The commercial use proposed for Building Two would be consistent with the views of commercial development of the Blossom Hill Pavilion at this intersection. Los Gatos Boulevard Plan. The project site is located within the plan area for the Los Gatos Boulevard Plan. The Plan provides direction and guidelines for overall development and improvements along Los Gatos Boulevard. In addition to the Plan, the Town has adopted the Los Gatos Commercial Design Guidelines, which include specific recommendations for the architectural treatment, organization, and mix of buildings and open space in the Los Gatos Boulevard Plan area. The project's consistency with these guidelines is discussed below in Section 10, Land Use and Planning, in Table 3 of the Initial Study. Architectural Review of Project Plans. The Town retained Cannon Design Group (CDG) to evaluate the project's architectural design and site plan for consistency with Design Standard objectives. In December 2009, CDG provided the Town with a letter report evaluating the architectural design elements of an initial site design. The project plans were subsequently revised prior to submittal to the Town. In response to project design revisions, the Town has required additional review of the revised design by CDG to determine the revised project's consistency with Town design guidelines. It should be noted that the revised project site plans include a reduction in the number of residential units from previous proposals and an increase in the total retail space proposed on the project site. The current project design also includes an architectural re -design of the commercial buildings to achieve better integration with surrounding commercial designs. The proposed landscaping, open space, and patio areas were expanded from the previous design. The proposed parking lot area was also expanded to meet the parking requirements for increased retail uses on the project site. In September 2010, CDG provided the Town with a subsequent review of the project's architectural design and site plan. The CDG review identifies issues of concern such as lack of integration between DECEMBER,2010 4 MITIGATED NEGATIVE DECLARATION— 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD residential and commercial uses, lack of public and private open space, residential building orientation, setbacks along Blossom Hill Road, lack of articulation in residential designs, design treatment for commercial entries on Los Gatos Boulevard and Blossom Hill Road, and location of senior unit garages. The review indicates that the commercial buildings are well designed with visual interest, appropriate details, and window treatments suitable to the architectural style. Comments provided by the CDG report included nine design considerations. The recommendations and comments include the following items: ■ The design should integrate proposed residential styles with commercial development design • Residential common open space is minimal and public open space is lacking ■ Larger setbacks on Blossom Hill Road, and between residential and commercial uses are needed ■ Horne entries should be designed to avoid facing rows of garages across narrow driveway • Front and side elevations of some 3-story units (e.g. French Country Style) would add substantial visual bulk ■ The proposed alignment of homes on Lots 1 through 5 is inconsistent with orientation of nearby uses • Senior housing lacks associated common open space ■ Commercial access from sidewalks would be desirable • Location of garages for senior housing should be reviewed for privacy and security concerns The proposed buildings would introduce new nighttime lighting to the project site. To reduce the potential for disturbance due to nighttime lighting, the project will need to satisfy Town Code Section 29.10.09035, which prohibits the production of direct or reflected glare (such as that produced by floodlight onto any area outside the project boundary). 2. Agriculture Resources: The 4.4-acre project site is currently developed with facilities associated with the former auto dealership use. Development of the proposed mixed -use project would replace the remnants of the site's previous commercial use with new residential and retail commercial development. Since the site is not in agricultural use and has no agricultural potential due to its small size, location, and previous use, the project would not adversely affect any existing agricultural resources or operations. Since the properties surrounding the project site are developed with commercial and residential uses, the proposed project would not adversely affect other agricultural properties or result in the conversion of farmland to non-agricultural use. 3. Air Quality: The San Francisco Bay Area Air Basin is classified by the Bay Area Air Quality Management District (BAAQMD) as non -attainment for ozone and inhalable particulates (PM10). To address these exceedances, the BAAQMD, in cooperation with the MTC and ABAG, prepared the Bay Area 2005 Ozone Strategy (BAOS) in September 2005 and Particulate Matter Implementation Schedule (PMIS) in November 2005. The PMIS discusses how the BAAQMD implements the California Air Resources Board's 103 particulate matter control measures. In September 2010, the BAAQMD adopted the 2010 Bay Area Clean Air Plan (CAP), which updates the BAOS. The consistency of the proposed project with the most recently adopted regional air quality plan, the CAP, is determined by comparing the project's consistency with the Los Gatos General Plan. Since the CAP is based on population projections of the Association of Bay Area Governments (ABAG) that are based on the Town's General Plan in effect at the time the CAP was approved, consistency of the project with the General Plan would indicate consistency with the CAP. While the proposed mix of uses would be allowed by the site's current DECEMBER,2010 5 MITIGATED NEGATIVE DECLARATION— 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD General Plan designation, the level of development for the site is not defined by the General Plan or Zoning Ordinance. However, the project's projected population growth would be consistent with ABAG's 2009 population projections, and therefore, the project would be consistent with the CAP. Construction Impacts. The project's construction -related air pollutant emissions would result from demolition, surface disturbance. The recently adopted BAAQMD CEQA Guidelines (June 2010) outline screening criteria, and considers a project's construction -related impact to be less than significant if it meets the screening level size, incorporates all Basic Construction Mitigation Measures, and does not include demolition, simultaneous occurrence of more than two construction phases, simultaneous construction of more than one land use type, extensive site preparation, or extensive material transport (more than 10,000 cy import/export). Since this project includes demolition and more than one land use type could be constructed simultaneously, the project's construction -related emissions were estimated based on project -specific construction factors and results are presented in Table 1 of the Initial Study (model output included in Attachment 2 of the Initial Study). As indicated in this table, the project's estimated emissions would not exceed the BAAQMD's significance thresholds for construction -related emissions. Therefore, the project's construction emissions are considered to be less than significant with implementation of the following BAAQMD-recommended Basic Construction Mitigation Measures: MITIGATION MEASURE 1: To limit the project's construction -related dust, criteria pollutant, and precursor emissions, the following BAAQMD-recommended Basic Construction Mitigation Measures shall be implemented: ■ All exposed surfaces (e.g., parking areas, staging areas, soil piles, graded areas, and unpaved access roads) shall be watered two times per day. ■ All haul trucks transporting soil, sand, or other loose material off -site shall be covered. ■ All visible mud or dirt track -out onto adjacent public roads shall be removed using wet power vacuum street sweepers at least once per day. The use of dry power sweeping is prohibited. ■ All vehicle speeds on unpaved roads shall be limited to 15 mph. ■ All roadways, driveways, and sidewalks to be paved shall be completed as soon as possible. Building pads shall be laid as soon as possible after grading unless seeding or soil binders are used. ■ Idling times shall be minimized either by shutting equipment off when not in use or reducing the maximum idling time to 5 minutes (as required by the California airborne toxics control measure Title 13, Section 2485 of California Code of Regulations [CCR]). Clear signage shall be provided for construction workers at all access points. ■ All construction equipment shall be maintained and properly tuned in accordance with manufacturer's specifications. All equipment shall be checked by a certified mechanic and determined to be running in proper condition prior to operation. ■ A publicly visible sign with the telephone number and person to contact at the Lead Agency regarding dust complaints shall be posted at the site. This person shall respond and take corrective action within 48 hours. The Air District's phone number shall also be visible to ensure compliance with applicable regulations. MITIGATION MONITORING: The Building Division of the Community Development Department will be responsible for ensuring that all measures are properly implemented during construction. DECEMBER,2010 6 MITIGATED NEGATIVE DECLARATION — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Operational Impacts. Air pollutant emissions associated with operation of the project would result primarily from project -related traffic (mobile sources) with a smaller increment from the project's space heating/cooling and electricity generation (area sources). The proposed project would generate approximately 1,647 average daily trips, with 194 AM peak hour trips and 146 PM peak hour trips. When trip generation from the former auto dealership is considered, the proposed mixed -use project would result in a net increase of 955 daily trips, with 151 AM peak hour trips and 92 PM peak hour trips. In accordance with recently adopted BAAQMD CEQA Guidelines (June 2010), the project's contributions to regional air quality (within San Francisco Bay Area Air Basin) were estimated using the CARB's URBEMIS 2007 computer model. The results for the project's operational average daily and annual emissions are presented in Table 2 of the Initial Study. This table indicates that pollutant emissions associated with average daily and annual project -related mobile and area sources would not exceed the recently adopted BAAQMD thresholds of significance for operational criteria pollutants and precursors. Since the BAAQMD thresholds address the impacts of project -related source emissions on local and regional air quality, the project's contribution to the total pollution burden in the region is considered to have a less -than -significant impact on local and regional air quality. 4. Biological Resources: The project site is developed with a parking lot and auto dealership buildings from previous commercial use of the property. Vegetation on the site consists of landscape trees, shrubs, and groundcover along the perimeter of the property, consisting primarily of street trees on Los Gatos Boulevard, Blossom Hill Road, and Placer Oaks Road. Trees along the southwestern boundary of the site serve as an effective screening element for the nearby residential properties on Blossom Hill Road. The habitat value of site vegetation is limited to urban -adapted species. Policy O.P.3.3 of the Open Space Element of the Los Gatos General Plan emphasizes preservation of public and private landscaping along Town streets. The Los Gatos Tree Protection Ordinance states that the preferred tree replacement is two or more trees of a species and size designated by the Director of the Parks and Public Works Department. Tree replacement requirements are based on canopy size, which is defined in Table 3-1 of the Ordinance, Tree Canopy — Replacement Standard. Tree canopy replacement requirements range from two to six 24-inch box size trees or two 36-inch and/or 48-inch box size trees, depending on the canopy size of the tree to be removed. A tree survey was prepared for the project by the Town's consulting arborist, Arbor Resources (AR), in November 2009 and updated in October 2010. Copies of these studies are on file with the Los Gatos Community Development Department. The AR assessment and revised project plans serve as the basis for the following evaluation of the project's potential effects on trees at the property. The AR survey identified a total of 38 trees that could be affected by the proposed project. Of these 38 trees, 37 are on the subject property and one is sufficiently close on the property adjoining the site as to be vulnerable to potential damage during development [Section 29.10.0995(B) of the Town's Municipal Code]. The 38 trees listed in the inventory include 12 that are located within the public right-of-way and are regarded as "street trees," (Trees #1 through 11, and 20). Tree #38 is situated on the neighboring western property, at the northwest property corner. Trees #23 through 33 are brush cherries (Eugenia myrtifolia) that form a row along the front, western section of the site. Their conditions vary from poor to good, but serve to provide an effective screen between the project site and the neighboring western residential property. Of the 38 trees on the site, 19 trees (#3, 5 - 8, 11, 13 - 22, and 35 - 37) would be removed as a result of project implementation. Trees #6, 7, 8, and 20 (all street trees) would be scheduled for removal due to required roadway widening of Placer Oaks Road and Blossom Hill Road. Based upon species, condition, DECEMBER,2010 7 MITIGATED NEGATIVE DECLARATION— 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD size, and assigned suitability for preservation, the proposed removal of all but four (Trees #5, 17, 19, and 22) of these trees would conform to Town code. Tree #17, a coast redwood (Sequoia senzpervirens), is located in the southwest corner of the property. The tree is situated within the footprint of proposed Lot 5. This redwood has a trunk diameter of 40 inches and a canopy spread of 35 feet. Its overall health is fair, possibly due to a lack of adequate water to the root zone. The AR report concludes that the tree appears sufficiently viable and its vigor could potentially be improved through regular watering, fertilization, and mulching. Without suitable irrigation, the tree's condition can be expected to decline further. With regard to Tree #5, this is a southern magnolia (Magnolia grandiflora) in good condition, located in the sidewalk strip in conflict with the proposed driveway to the commercial building on Placer Oaks Road. Trees #19 and 22 are crape myrtles (Lagerstroemia indica) in healthy and apparently stable condition. These trees would be suitable for relocation rather than removal. The AR report also provides an assessment of Tree #12, a coast redwood that is situated along western perimeter of the project site. Although planned for retention, Tree #12 would be severely impacted and subjected to premature demise and instability. This is a large redwood that has a 40-inch trunk diameter, an extremely sparse canopy, and appears beyond recovery. The proposed new parking spaces adjacent to Lot 6 would be only a few feet from its trunk and, due to overcut to form and pour the curb and gutter, root loss or trunk damage at its base would be expected. When considering this tree's poor and irreversible condition, redesign to avoid this impact does not seem warranted and it should be removed. If efforts were made to retain this tree, the AR report recommends that the three parking spaces planned for this area should be omitted from the design to achieve a minimum setback of 20 feet from its trunk for any ground disturbance. The Town will require implementation of the following measure to reduce impacts on trees to be retained, and adequately replace trees to be removed: MITIGATION MEASURE 2: With review and approval by the Town, all recommendations made by Arbor Resources (October 11, 2010 and any updates) will be implemented to eliminate or minimize the construction -related impacts on the trees to be retained. Recommendations are listed under Section 5.0, Recommendations, of the arborist's report. These include recommendations under the Design Guidelines section addressing tree retention and relocation, soil disturbance, mulching, trenching, drainage facilities, and installation of new trees. The report also provides recommendations for Protection Measures before and during construction, encompassing fencing, removal of hardscape, demolition, work within tree canopies, etc. The report's recommendations are included as Attachment 3 of the Initial Study. MITIGATION MONITORING: The Planning Division of the Community Development Department will be responsible for ensuring that all recommendations made by the arborist are reflected in final project plans. The Building and Planning Divisions of the Community Development Department will be responsible for ensuring that all tree protection measures are properly implemented during construction. 5. Cultural Resources: Project implementation would result in demolition of existing buildings on the site. No significant impacts on historic resources would result from the proposed demolition. An archaeological literature review was undertaken by Holman & Associates at the Northwest Information Center (NWIC) located at Sonoma State University (file no. 09-1292) to obtain information DECEMBER, 2010 8 MITIGATED NEGATIVE DECLARATION — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD about recorded historic and prehistoric archaeological sites in and around the project area, and information about previous archaeological field studies of the project area and its surroundings. A copy of the Holman report is on file and available for public review at the Los Gatos Community Development Department. The review of NWIC records indicates that there has been no previous archaeological field inspection of the project area, and that there are no recorded historic or prehistoric sites inside the project borders, or within 1,000 feet of the project site. The NWIC inventory maps indicate a possible archaeological site (otherwise not described) located along Blossom Hill Road west of the project area. Holman & Associates conducted a visual inspection of the project site as part of their evaluation of the project site for the presence of potential archaeological resources. No evidence of historical or archaeological resources was discovered during either the field inspection or the literature review. Holman concluded that the project site has a low potential for containing buried cultural resources, and therefore, mechanical subsurface presence/absence testing is not warranted, nor is it recommended that an archaeologist be present during construction -related earthmoving activities. However, since over 90% of the ground surface on the project site is covered either by buildings, pavement, and/or landscaping, the potential for discovery of obscured cultural resources during future development of the project site would still remain. Given the site's proximity to the historic alignment of Los Gatos Creek and proposed grading for residential and commercial construction, the potential for encountering cultural resources cannot be completely eliminated. Therefore, the following mitigation measures will be required: MITIGATION MEASURE 3: Construction personnel involved with earthmoving shall be alerted to the potential for the discovery of prehistoric materials and in particular, concentrations of historic artifacts. Prehistoric archaeological resources could include but not be limited to the following: darker than surrounding soils of a friable nature, concentrations of stone, bone or fresh water shellfish, artifacts of these materials, and evidence of fire (ash, charcoal, fire altered earth or rock) and of course, burials, both human and animal. MITIGATION MEASURE 4: In the event that archaeological traces are encountered, all construction within a 20-foot radius of the find shall be halted, the Community Development Director shall be notified, and an archaeologist shall be retained to examine the find and make appropriate recommendations. MITIGATION MEASURE 5: In the event that it appears further earthmoving will affect a resource eligible for the California Register of Historic Resource (CRHR), a plan for evaluation of the resource through limited hand excavation should be submitted to the Town's Community Development Department for approval. If evaluative testing demonstrates that the project will affect a CRHR eligible resource, a plan for the mitigation of impacts to the resource should be submitted to the Community Development Department for approval before construction is allowed inside the zone designated as archaeologically sensitive. MITIGATION MEASURE 6: If the Community Development Director finds that the archaeological find is not a significant resource, work will resume only after the submittal of a preliminary archaeological report and after provisions for reburial and ongoing monitoring are accepted. Provisions for identifying descendants of a deceased Native American and for reburial will follow the protocol set forth in CEQA Guidelines Section 15064.5(e). If the site is found to be a significant archaeological site, a mitigation program will be prepared and submitted to the Community Development Director for consideration and approval, in conformance with the protocol set forth in Public Resources Code Section 21083.2. DECEMBER,2010 9 MITIGATED NEGATIVE DECLARATION— 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD MITIGATION MEASURE 7: A final report shall be prepared when a find is determined to be a significant archaeological site, and/or when Native American remains are found on the site. The final report will include background information on the completed work, a description and list of identified resources, the disposition and curation of these resources, any testing, other recovered information, and conclusions. MITIGATION MONITORING: The Planning and Building Divisions of the Community Development Department will be responsible for ensuring that these measures are implemented appropriately during construction as the need arises. 6. Geology and Soils: A review of the Town's hazards maps indicates that the project site has a moderate shrink -swell potential, very low potential for liquefaction, moderate potential for fault rupture, and moderate potential for seismic shaking. Due to the site's relatively level topography, no erosion, slope stability, or debris flow hazards were identified for the site. The Town's Fault Map indicates that there is a concealed fault trace that may traverse the northeast corner of the site. Cornerstone Earth Group (CEG) conducted a geotechnical investigation of the project site and presented the results of the analysis in a report dated October 21, 2009. The CEG geotechnical investigation consisted of field and laboratory programs to evaluate physical and engineering properties of the subsurface soils (including borings), review of aerial photos, and engineering analysis. The Town retained AMEC Geomatrix Consultants, Inc. (Geomatrix), a geotechnical consulting firm, to review the CEG study. The Geomatrix assessment (dated December 3, 2009) concluded that the CEG geotechnical study characterized the project site and generally made appropriate recommendations for the project. Geomatrix identified three residual concerns that required further evaluation by CEG. These concerns addressed the geologic and seismic conditions, and geotechnical engineering considerations as these relate to the proposed project. On December 18, 2009, CEG provided additional information and clarification on its analyses in a response to the Geomatrix review. In a March 23`d 2010.1etter, Geomatrix provided additional observations concerning CEG responses and concurred with CEG that the proposed project is feasible, provided CEG's geotechnical engineering recommendations are incorporated into the project design. Copies of all reports are on file at the Los Gatos Community Development Department. The property is located east of Los Gatos Creek, on an alluvial plain that is rimmed on the west, south and east by the foothills of the Santa Cruz Mountains. The subject property is underlain, at depth, by sedimentary bedrock materials of the Tertiary -age Monterey Shale and Temblor Sandstone formations. However, bedrock units were not observed in the site vicinity due to concealment by overlying valley floor sediments. According to CEG, regional geologic maps indicate that the overlying sediments are Pleistocene -age alluvial fan deposits. The depth to Tertiary bedrock below the property is not known, but is assumed to be on the order of 100 feet or more. Geotechnical borings previously drilled on the site in 2006 encountered imported fill and the native alluvial materials consisting of clayey sands and clayey sands with gravels, cobbles, and boulders. A small area of artificial fill encountered near the center of the property is associated with an excavation and loose backfill by the previous property owner. CEG indicated that the project site is not located in a currently designated Alquist-Priolo Earthquake Fault Zone. However, the property is situated within the Santa Clara County Fault Hazard Zone, which is based on mapping of the Shannon fault zone. A concealed, possible fault trace that is projected more than a mile from a fault observed in the Blossom Hill area is depicted as crossing the northeastern comer of the property. DECEMBER, 2010 10 MITIGATED NEGATIVE DECLARATION— 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD The property is located in a "moderate" fault rupture potential zone, according to the Town of Los Gatos fault rupture hazard zone categories. The "moderate" category includes properties that meet one of the following criteria: 1) areas located within 400 to 500 feet of the dotted, concealed fault traces; 2) areas containing concentrated clusters of mapped aerial photo lineaments; or 3) areas with widespread evidence of coseismic deformation caused by the 1989 Loma Prieta earthquake. The property is not located within an area of mapped aerial photo lineaments or coseismic deformation caused by the 1989 Lorna Prieta earthquake. However, fault mapping for the project area indicates that the property is located within 400 to 500 feet of a concealed fault trace. According to CEG, the Geotechnical and Seismic Safety Element Working Paper for the Town of Los Gatos recommends that fault hazard studies (i.e. geologic investigations that include trenching) be prepared for structures situated in the "high" ground rupture potential category, but not for structures in the "moderate" category. Based on review of available information as well as site -specific data, CEG concluded that the potential for fault rupture hazards at the site during the lifetime of the project is considered to be low. CEG also determined that the potential for liquefaction, lateral spreading, or seismic settlement to occur at the site is low. However, CEG indicated that the proposed project, similar to other development in the Bay Area, would be subject to strong ground shaking in the event of a moderate to severe earthquake. The primary geotechnical concern identified by CEG is differential settlement that could occur in engineered fill when in proximity to dense native soils. The review by Geomatrix recommended further evaluation of the potential for this hazard to occur with project development. CEG has indicated that the slight increase in potential differential settlement could be accommodated in the structural design of the building foundations. The following measure shall be required to reduce potential geotechnical hazards to a less -than - significant level: MITIGATION MEASURE 8: The recommendations of the CEG geotechnical investigation and project review (October 21, 2009 and December 18, 2009) shall be incorporated in the final construction plans for the proposed project (Attachment 4 of the Initial Study). These recommendations address site preparation, earthwork operations, drainage, and foundations. MITIGATION MONITORING: The Building Division of the Community Development and Engineering Division of the Parks and Public Works Departments will be responsible for ensuring that all recommendations are incorporated into the project design and properly implemented during construction. 7. Greenhouse Gases: Implementation of the proposed project would contribute to long-term increases in greenhouse gases (GHGs) as a result of traffic increases (mobile sources) and minor secondary fuel combustion emissions from space heating, etc. Development occurring as a result of the proposed project would also result in other secondary operational increases in GHG emissions as a result of electricity generation to meet project -related increases in energy demand. Electricity generation in California is mainly from natural gas -fired power plants. However, since California imports about 20 to 25% of its total electricity (mainly from the northwestern and southwestern states), GHG emissions associated with electricity generation could also occur outside of California. Space or water heating, water delivery, wastewater processing and solid waste disposal also generate GHG emissions. Short-term GHG emissions would also be generated by project -related construction activities. DECEMBER,2010 11 MITIGATED NEGATIVE DECLARATION— 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD The General Reporting Protocol (GRP) in the California Climate Action Registry (CCAR) divides project -related operational GHG emissions into three categories. These three sources include the following: Source 1: On -site combustion of fossil fuels (space and water heating, fireplaces, landscape utility equipment, etc.) Source 2: Consumption of purchased energy (electricity) Source 3: Indirect emissions (transportation, solid waste disposal, fresh -and wastewater conveyance and treatment) For general development projects such as the proposed project, Source 3 is typically a much larger contributor to the GHG burden than Sources 1 and 2. For purposes of analysis, project -related GHG emissions were aggregated into transportation and non -transportation sources. The transportation component is calculated and reported in the URBEMIS2007 computer model. The non -transportation sources require separate analysis, and both calculation methods are included in Attachment 2 of the Initial Study. Construction Impacts. Project construction would generate exhaust emissions from off -road equipment, on -road trucking, and construction worker commuting traffic during this period, but these emissions are expected to contribute minimally to long-term regional increases in GHGs. No state agency or the BAAQMD has adopted a methodology or quantitative threshold that can be applied to a specific development project to evaluate the significance of an individual project's construction -related contribution to GHG emissions, such as those that exist for criteria pollutants. However, the recently adopted BAAQMD CEQA Guidelines recommend that a project's construction -related GHG emissions be quantified and a significance determination be made in relation to meeting AB 32 GHG reduction goals. Pursuant to the BAAQMD Guidelines, the URBEMIS2007 computer model was used to estimate the project's construction -related GHG emissions. Project -related construction activities are estimated to generate a maximum of approximately 89 short tons (91 metric tons, MT) in 2010 and 523 short tons (475 MT) in 2011 of CO2 (see URBEMIS Model output in Attachment 2 of the Initial Study). Since equipment exhaust also contains small amounts of methane and nitric oxides, also GHGs, the project's total CO2-equivalent (CO2e) emissions (all GHGs) would be approximately 91 MT in 2010 and 475 MT in 2011.1 While there is no adopted or proposed significance threshold for construction -related emissions, the construction -related GHG emissions would be well below the proposed BAAQMD significance threshold for long-term operational emissions of 1,100 MT of CO2e per year. Therefore, the project's construction -related GHG impacts would not conflict with the state's goals of reducing GHG emissions to 1990 levels by 2020, and is considered less than significant. Implementation of Mitigation Measure #1, which limits idling of construction equipment (as required by Title 13 of the California Code of Regulations, Section 2485), would also further reduce the project's construction -related GHG emissions. Operational Impacts. Implementation of the proposed project would contribute to long-term increases in greenhouse gases (GHGs) as a result of traffic increases (direct emissions from mobile sources) and minor secondary fuel combustion emissions from electrical consumption, space heating, etc. (indirect When CO2 and non-0O2 GHG emissions are considered together, they are referenced as CO2-Equivalents (CO2-E), which add approximately three percent to CO2 emissions from diesel equipment exhaust. DECEMBER, 2010 12 MITIGATED NEGATIVE DECLARATION — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD emissions from non -mobile sources). Estimated annual GHG emissions, from project -related direct and indirect would be as follows: ■ Total Non -Transportation 449 tons/year ■ Total Transportation 2,152 tons/year ■ Combined CO2e 2,601 tons/year or 2,365 MT/year The recently adopted BAAQMD CEQA Guidelines include the following significance thresholds for GHG: annual GHG emissions of 1,100 MT or 4.6 MT/service population (residents and employees). The project's annual emissions would exceed the 1,100 MT annual threshold and would also exceed the 4.6 MT per person threshold (2601 MT per 131 residents and 38 employees). Therefore, the project's operational GHG emissions are considered potentially significant. Therefore, it is recommended that energy efficiency measures be incorporated into the proposed building to the maximum extent feasible until such time that a methodology is adopted and mitigation can be applied. While the proposed building will be required to comply with energy efficiency requirements of the California Energy Code (Title 24, Part 6 of the California Administrative Code), the Town will also require completion of the LEED checklist for commercial portion of the project and GreenPoint checklist for single-family residential portion (pursuant to the Town's adoption of near -term policy recommendations from the Santa Clara County Cities Association Green Building Collaborative in April 2008). The Town has not adopted rating standards for private development, but adopted the LEED Silver standard for all new public construction and renovation projects over 5,000 s.f. The project applicant completed the LEED and GreenPoint checklists and based on proposed energy efficiency features, the project would meet the LEED Platinum standard, LEED's highest standard. The project is estimated to achieve a GreenPoint rating score of 148, which exceeds the minimum GreenPoint rating score of 50 points. The GreenPoint checklist considers project design elements, but also considers recycling of construction waste, community planning (i.e. infill), and material source locations (within 500 miles). Pre -certification LEED and GreenPoint estimates are included as Attachment 5. Implementation of LEED and GreenPoint standards is considered to reduce the project's impact to a less -than -significant level since this would be consistent with the Town's adopted GHG policies. For the proposed project, the transportation component would comprise approximately 83% of the project -related GHG emissions. Reductions in the vehicular contribution are therefore critical in achieving adopted state and local goals for reducing GHG emissions. However, except for encouraging infill development, achieving substantial mobile sources emissions reductions by reducing vehiculartrips or trip lengths and increasing vehicle fuel efficiency are not achievable on a project -specific basis. State and national programs are in place to significantly upgrade fuel efficiencies. The proposed mix of uses, internal pedestrian connections proposed (paseos), centralized project location (infill development) would help to capture or share trips, encourage pedestrian access to nearby commercial amenities. The project's location on a bus route would also encourage use of transit, particularly with the provision of senior housing at this location. GHG reduction measures that can be implemented on a project -level basis are similar to measures that also reduce criteria air pollutants. In general, measures that reduce trip generation or trip lengths, optimize the transportation efficiency of a region, and promote energy conservation within a development will reduce GHG emissions. Additionally, carbon sequestering can be achieved through urban forestry measures. Project -specific design measures that could be implemented to reduce the project's contribution to the cumulative GHG impacts include the following: DECEMBER,2010 13 MITIGATED NEGATIVE DECLARATION— 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Land Use and Transportation • Promote increased utilization of public transit • Provide continued support for rideshare programs to encourage the use of alternatives to the single occupant vehicle (SOV) for site access and trips originating at the site Energy Conservation • Construct the new residential building to exceed California Title 24 energy efficiency requirements by ten (10) percent. • Construct the new commercial buildings to meet LEED (Leadership in Energy and Environmental Design) Silver Certification • Maximize use of low pressure sodium and/or fluorescent lighting • Require acquisition of new appliances and equipment to meet Energy Star certification Urban Forestry • Participate in green waste collection and recycling programs for landscape maintenance • Encourage use of landscaping with low water requirements and fast growth. • Plant trees or vegetation to shade buildings and thus reduce heating/ cooling demand As indicated in the LEED and GreenPoint checklists completed for the project, three of the above measures have been incorporated into the project design. The project site is located adjacent to a bus stop, the commercial component of the project would exceed the LEED Silver standard, Energy Star appliances are proposed to be installed, landscaping is proposed to be have low water requirements, and shade trees would be planted. 8. Hazards and Hazardous Materials: A Phase I Environmental Site Assessment (ESA) was conducted for the project site by EFI Global in February 2006. The ESA is on file with the Los Gatos Community Development Department. The project site was used for agricultural purposes (fruit orchard) from at least 1939 until 1959. By 1959, the eastern and northern portions of the site were developed by Mr. Paul Swanson as a car sales and service dealership. The auto dealership consisted of two buildings and a covered auto detail area: • The first building, located in the eastern portion of the project site, was used as an auto showroom, offices, parts department, and service area. • The second building, located in the center of the site, had office and lunch areas,, a car wash, and service bays. • The covered detail structure and outdoor service area, located between these two buildings, has one three -stage clarifier on the northeast side of the detail area, a second clarifier located west of the third building, 25 underground hydraulic lifts located in service areas of the facility, and five aboveground hydraulic lifts in an outdoor service area located between the first and second buildings. The residence remained in use on the southwestern portion of the site until sometime between 1965 and 1971. The residence was then removed and the dealership expanded into that area with the construction of a building, which was initially used for the sales and service of recreational vehicles (RVs). This building has offices, a spray booth and service area. In 1991, two underground storage tanks (UST) were removed from the project site. Subsurface investigations and remediation were conducted subsequent to their removal in 1991. Based on the results DECEMBER, 201'0 14 MITIGATED NEGATIVE DECLARATION — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD of the investigation, the Santa Clara County Valley Water District provided a Case Closure letter for the project site regarding these USTs on December 29, 1995. In 1993, five additional USTs were removed. Petroleum hydrocarbon constituents were detected below the waste oil piping. Additional sampling conducted in the piping area did not reveal the presence of petroleum hydrocarbons, and a 1997 letter from the Santa Clara County Fire Department indicates that the UST closures were considered complete by that agency. According to the regulatory agency database report obtained by EFI, several off -site facilities have reported that the subsurface below those off -site facilities is impacted with petroleum hydrocarbons and chlorinated solvents. However, based on review of Santa Clara County Department of Environmental Heath (SCCDEH) Leaking Underground Storage (LUST) case files and Santa Clara County Valley Water District (SCCVWD) Solvent Case file, these facilities do not appear to be a potential environmental concern to the project site at this time based on distance and direction from the site with respect to groundwater flow direction and gradient. Based upon reconnaissance of the project site and adjacent properties, review of regulatory agency lists and files, review of historical documents and interviews with knowledgeable persons, the EFI assessment reveals the following evidence of recognized environmental conditions (RECs) in connection with the site: ■ One groundwater monitoring well was installed at the project site as part of a LUST investigation, conducted in 1991. The investigation was completed, and the project site received Case Closure in 1995. It appears that this well has not been used since 1991, and should have been properly abandoned prior to granting of the closure status of the site, and was probably inadvertently missed. EFI recommends that this groundwater monitoring well should be properly destroyed under permit to the proper regulating agency. • While the facilities on the project site appeared in good condition overall, some spillage has been noted in the past by SCCDEH and SCCFD hazardous materials inspectors. In addition, some staining and spillage was noted at the time of the site visit. While spills were reportedly cleaned with absorbent material and concrete flooring in service areas generally appears to be in good condition, it is possible that some impact on the subsurface soils has occurred during the time the project site was used as a dealership and repair facility. There are 26 underground and hydraulic lifts, and most of these have a subsurface oil reservoir enclosed in the piston of each lift. There was also one other underground lift in the car wash area adjacent to the body shop (formerly located in the second building) that was reportedly abandoned and removed, but no soil sampling was done at the time of the removal. EFI recommends that removal of these lifts be observed and soil samples collected as part of the removal process. • There are two clarifiers (exterior oil/water separators) on the project site. EFI recommends that the clarifiers be removed and that the condition of the soil below these features be assessed. • A stormwater sump is located on the southeast side of the second building and it is used to collect stormwater, then direct it northward toward storm drains located along the northern site boundary. The proximity of this sump in proximity to the hazardous materials storage and service areas of the facility poses an environmental concern. EFI recommends that the soils below this feature be assessed to evaluate subsurface soil conditions in the vicinity of this feature. DECEMBER, 2010 15 MITIGATED NEGATIVE DECLARATION - 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD ■ Hazardous materials have been stored on the site and a Hazardous Materials Management Plan/ Hazardous Materials Business Plan (HMMP/HMBP) is maintained with the SCCFD. A facility closure notice documenting compliance with the Santa Clara County Fire Department (SCCFD) requirements should be obtained. Based on EFI's experience with other facility closures within Santa Clara County, it is likely that the facility closure would involve the removal of the hoists, sumps, clarifier, hazardous materials and debris. Any confirmation soil sampling and subsurface closure activities would be overseen by the Santa Clara County Department of Environmental Health (SCCDEH). During this assessment of the subject property, EFI has identified the following potential environmental issue, which is not considered a REC: ■ A limited visual asbestos -containing materials (ACMs) survey was conducted at the site. The facility was constructed in 1959 when ACMs were still commonly used in building materials. In addition, limited testing of potential ACM conducted in 1996 revealed the presence of ACM in heating duct insulation and wrap in the first building. Potential ACM observed during the site inspection included wallboard and joint compounds, roofing materials, and vinyl floor tiles and sheeting. Although no inspection for lead -based paints was conducted by EFI, it is possible that lead -based paints could also be present in existing structures. Proposed demolition of these structures could result in airborne release of hazardous building materials, such as asbestos fibers or lead dust. If found to be present in building materials to be removed, asbestos and/or lead abatement practices such as containment and removal will be required prior to demolition. The project applicant will be required to obtain clearance for asbestos removal from the Bay Area Air Quality Management District prior to issuance of a demolition permit. Therefore, compliance with this requirement will reduce to less than significant the potential for public health hazards associated with the release of airborne asbestos fibers at the project site. Due to the extent of grading required, proposed demolition of existing facilities and proposed removal of underground facilities, the following measures will be required to reduce potential hazardous materials impacts to a less -than -significant level: MITIGATION MEASURE 9: The project applicant and/or Town shall prepare a management plan to identify all suspected hazardous materials and specify applicable regulations that would determine appropriate handling and disposal of these materials. For suspected hazardous materials (contaminated soil and groundwater) that may be encountered during construction, the management plan shall include contingency plans for site safety, worker protection, sampling and investigation, and disposal or remediation; these shall be based on soil and groundwater sampling and testing that have been completed to date. The management plan shall be filed with the Town of Los Gatos and all other jurisdictional agencies prior to issuance of the demolition and grading permits. MITIGATION MEASURE 10: If groundwater is encountered during project construction and dewatering is required, the project applicant shall undertake sampling and testing of the encountered groundwater in accordance with the contingency sampling and investigation plan. If groundwater is found to contain contaminants that exceed regulatory action levels, it may not be discharged into the existing storm drainage system. Removal and handling of the contaminated groundwater should be done in a manner acceptable to the RWQCB, the Town, and other jurisdictional agencies. DECEMBER,2010 16 MITIGATED NEGATIVE DECLARATION — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD MITIGATION MEASURE 11: A state certified lead -based paint professional shall be retained to perform a lead -based paint survey of the existing structures and the recommendations of the professional shall be followed for abatement of any identified Lead -based paint prior to demolition of the structures. MITIGATION MONITORING: The Building and Planning Divisions of the Community Development Department will be responsible for ensuring that these measures are implemented prior to construction. 9. Hydrology and Water Quality: Storm Drainage. Approximately 95 percent (or 186,363 s.f.) of the 4.4-acre project parcel is covered with the impervious surfaces of the site's building, concrete slab foundation and asphalt parking lot. Project development would result in approximately 75 percent (147,909 s.f.) of the site being covered by driveways, parking, sidewalks, or building. This would result in approximately 20 percent net decrease in impervious surfaces on the project site and potential reduction in peak surface flows from the project site, a beneficial impact of the proposed project. Presently, storm runoff flows on the project site discharge to storm drains on the site, which connect to two 18-inch storm drains in Los Gatos Boulevard. Since the project would result in a net reduction in impervious surfaces, the project would not adversely affect the capacity of existing storm drains. Flood Hazards. According to the Federal Emergency Management Agency's (FEMA) Flood Insurance Rate Map (FIRM) (May 18, 2009) for Los Gatos, the project site is located in Zone X, consisting of areas with 0.2% annual chance of flood, areas of one percent annual chance flood with average depths of less than one foot or with drainage areas less than one square mile, and areas protected by levees from one percent chance flood. The Hydrology and Water Quality Map in the Background Report for the General Plan Update also indicates that the project site is located outside mapped 100-year flood hazard areas. Water Quality. Stringent water quality regulations of the Clean Water Act have recently been triggered because the NPDES (National Pollution Discharge Elimination System) permit program has failed to protect beneficial uses of Santa Clara County's creeks and the South San Francisco Bay, as evidenced by such observations as violations of ambient water quality criteria, high concentrations of toxic substances, and fish consumption health advisories, These regulations require that all discharges shall comply with Provision C.3, New and Redevelopment Performance Standards of Order No. 01-024 of the NPDES permit program. The project site is located within the Los Gatos Creek watershed and runoff from the site ultimately discharges into Los Gatos Creek (west of the site) and eventually into the Bay. Los Gatos Creek is on the Clean Water Act Section 303(d) List of Water Quality Limited Segments due to the presence of diazinon, a pesticide, and its primary source is identified as urban runoff and storm drains. Best Management Practices (BMPs) outlined by the Santa Clara Valley Urban Runoff Pollution Prevention Program (SCVURPPP) for treatment control of pesticides are bioretention, infiltration, and media filter with adsorption/absorption as the removal process. After project completion, surface runoff from the site would be expected to carry typical urban pollutants generated by parking lots, building surfaces, and landscape areas. As a condition of project approval, the Town will require preparation and implementation of interim and final erosion control plans as well as non -point source pollution prevention measures such as installation of filtration devices or use of bio- swales. Implementation of such measures would reduce potential water quality impacts to a less -than - significant level. Project plans include a preliminary grading plan and a stormwater management plan DECEMBER,2010 17 MITIGATED NEGATIVE DECLARATION— 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD that identify existing and proposed drainage facilities for the site. The proposed drainage plan delineates runoff source control measures and Best Management Practices (BMPs) to be used in the control of runoff originating on the project site. The proposed treatment measures for this project are three proprietary, manufactured bioretention units, and two bioswales. The three units would be located in the area of the residential lots and would treat street, driveway, walkway, and building runoff. The roof downspouts from the single-family homes would drain to landscaping and excess runoff would flow to the street.. The two bioswales, shown in four segments on project plans, would be located on the eastern edge of the site along Los Gatos Boulevard and would drain the remainder of the retail area and entrance road. The proposed project involves removal and replacement of more than 10,000 s.f. of impervious surfaces and thus must satisfy C.3 numerical requirements for treatment. The C.3 requirements also specify thata trash enclosure area is to be covered and connected to the sanitary sewer system. Since the area of disturbance would involve more than one acre, a Storm Water Pollution Prevention Plan (SWPPP) would be required by the Town. The State General Permit requires the applicant to file a Notice of Intent (NOI) to obtain coverage, and to prepare a Stormwater Pollution Prevention Plan (SWPPP) for the construction phase of the project. The Town is responsible for ensuring that the applicant has filed the NOI and that the SWPPP is consistent with local ordinances. With the required SWPPP, the project's potential impact on water quality would be less than significant. Final detailed plans and calculations will be submitted to the Town for final review and approval. In order to determine the adequacy of the water quality control measures proposed by the project, the Town has retained an engineering consultant, Eisenberg, Olivieri & Associates (EOA), to review submitted project plans for compliance with the stormwater requirements in the Town's NPDES Permit. The EOA reviews of the project (included as Attachment 6) indicate that the total amount of impervious surface created and/or replaced at this site is 147,909 square feet (3.4 acres). Since this is greater than the C.3 threshold of 10,000 square feet, the C.3 treatment requirements would apply to this project. During the review process the project plans were revised to address recommendations provided by EOA's Memorandum dated May 22, 2010. EOA's subsequent review dated November 15, 2010 of the revised plans indicates that the project's proposed stormwater treatment facilities have incorporated some of the EOA recommendations (e.g. reduction of mechanical treatment and use of bioswale treatment of all commercial area runoff). The applicant has also committed to the use of additional landscape areas for stormwater filtration pending the results of a soils investigation to determine percolation characteristics of site soils. Although no design details for the bioswales are included in the proposed stormwater treatment plans, the BOA review indicates that the area reserved for the bioswales ranges from about 5 to 20% of the contributing area and concludes that this area would be sufficient for adequate treatment. The engineering review of the project indicates that the stormwater treatment measures specified for this project meet the Town's NPDES Permit Provision C.3 requirements, and therefore, the project's water quality impact would be less than significant. The project site is located in a "red" area of the Santa Clara Valley Urban Runoff Pollution Prevention Program (SCVURPPP) Hydromodification Management Plan (HMP) Applicability Map, which means that the site is exempt from hydromodification requirements. Also, projects that do not create an increase in impervious surface over pre -project conditions are exempt. Since the proposed project would reduce the amount of impervious surface on subject property, the project is not required to implement hydromodification control measures. DECEMBER, 2010 18 MITIGATED NEGATIVE DECLARATION— 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD The preliminary erosion control measures shown on the project plans (Sheet C-8.0) are consistent with the Town's ordinances addressing stormwater pollution control and erosion and sediment control requirements. 10. Land Use and Planning: The site is currently developed with facilities related to the former auto dealership use, paved parking lots, and landscaping. The project parcel is currently designated by the existing General Plan as "Mixed Use Commercial," while the site is zoned "CH, Restricted Highway Commercial." The Mixed Use Commercial General Plan designation allows for "a mixture of retail, office, residential in a mixed use setting, along with lodging, service, auto -related businesses, non - manufacturing industrial uses, recreational uses and restaurants." The CH zone allows retailing, office, service business, and limited manufacturing uses. The proposed project's mix of retail commercial and residential uses would be consistent with these General Plan and Zoning Ordinance land use designations for the site. The project applicant proposes to add a Planned Development (PD) zone (CH:PD) because the General Plan encourages sites larger than 40,000 square feet to be processed as a PD. Additionally, the Town Council directed staff to process a proposed change in land use from auto dealership to other uses as a PD. The density of the residential portion of the project is proposed to be 12.1 units per acre. Existing multi- family residential development located adjacent to the project's western boundary have higher densities of 18.4 units per acre and 20 units per acre. The single-family neighborhood to the northwest has a lower density of approximately 5 units per acre. The project's consistency with CEQA-relevant plans and policies is presented in Table 3 of the Initial Study. The Los Gatos General Plan and its Elements, Commercial Design Guidelines, and Los Gatos Boulevard Plan contain goals, policies, and implementation strategies that pertain to future development of the project site. However, Section 15131 of the CEQA Guidelines states that the "economic and social effects of a project shall not be treated as significant effect on the environment." Many of the goals, policies, and strategies of these plans and guidelines relate to the economic and fiscal well-being of the community as well as architectural design, and are not a subject for discussion in this CEQA document. Only those goals, policies, strategies, and guidelines that could result in a physical environmental change are listed and evaluated in Table 3 of the Initial Study. However, these policies will be considered separately by Town staff, as part of the Town's project review and approval process. The project vicinity is comprised of a mix of commercial, office, and residential uses. Adjacent parcels to the north, south, southeast, and east of the project site (also fronting on Los Gatos Boulevard) are currently in retail commercial or office use; residential development adjoins the project site to the west. The proposed residential use on the western portion of the site would be consistent with existing multi- family residential (apartment) uses located along the western project boundary and single-family residences adjacent to the northwestern project boundary (across the street). The proposed retail commercial buildings on the eastern portion of the site would be consistent with the existing mix of retail commercial and office uses to the north, east, and south. However, proposed senior apartments on the eastern portion of the site would not be consistent with adjacent office and commercial uses. Although residential use is allowed in the Mixed Use Commercial General Plan designation, it is a conditional use in the CH zone (a conditional use permit is required). In 1997, the Town completed the Los Gatos Boulevard Plan, which presents the Town's vision for the development of the Los Gatos Boulevard corridor. The Plan provides land use goals and guidelines for the Los Gatos Boulevard Plan area, which includes the project site. While the Plan does not include specific direction for land use at the project site, the proposed retail commercial component of the project DECEMBER,2010 19 MITIGATED NEGATIVE DECLARATION — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD would be consistent with existing commercial uses to the east, south, and southeast, while the proposed residential use would be consistent with residential uses to the north and west of the site. By locating residential uses adjacent to existing residential uses and retail commercial uses contiguous to existing retail commercial uses, the project attempts to minimize land use compatibility problems with existing uses. 11. Mineral Resources: The Los Gatos General Plan does not identify any regionally or locally - important mineral resources on the project site or in its vicinity. 12. Noise: Construction Noise. Project construction would result in temporary short-term noise increases due to the operation of heavy equipment. Construction noise sources range from about 76 to 85 dBA at 50 feet for most types of construction equipment with slightly higher levels of about 88 to 91 dBA at 50 feet for certain types of earthmoving and impact equipment. If noise controls are installed on construction equipment, the noise levels could be reduced by 1 to 16 dBA, depending on the type of equipment. The potential for construction -related noise increases to adversely affect nearby residential receptors would depend on the location and proximity of construction activities to these receptors. The Town Noise Ordinance (Chapter 16) restricts construction activities to the hours of 8:00 a.m. to 8:00 p.m. on weekdays and 9:00 a.m. to 7:00 p.m. on weekends and holidays. This ordinance also limits noise generation to 85 dBA at the property line or 85 dBA at 25 feet. Adjacent uses include condominiums and the Valley Oaks Apartments located 15 to 70 feet from the western project boundary, two single-family homes located across Placer Oaks Road, approximately 90 feet from the northern project boundary, an office building located approximately 80 feet from the northern project boundary, as well as retail commercial buildings located approximately 150 feet from the eastern project boundary and 100 feet from the southern project boundary. There is also a combination of masonry, wood, and chainlink fencing located along the western project boundary. While construction equipment is expected to operate at least 50 feet from adjacent condominiums and apartments most of the time, there is one area in the southwest corner of the site where construction equipment could operate as close as 15 to 20 feet from existing condominiums and apartments for short periods. At 50 feet, the ordinance noise limit would result in maximum noise levels of 79 dBA at the closest condominiums to the northwest, while at 15 to 20 feet, Valley Oaks Apartments to the southwest would be subject to maximum noise levels of up to 89 dBA when equipment operates adjacent to the southwestern project boundary. Temporary disturbance (e.g., speech interference) can occur if the noise level in the interior of a building exceeds 45 to 60 dBA. To maintain such interior noise levels, exterior noise levels at the closest residences (with windows closed) should not exceed 70 to 80 dBA and this exterior noise level is used as a significance threshold or criterion. It appears that construction noise levels could be maintained below 80 dBA most of the time except when equipment is operated in the southwest corner adjacent to the project boundary. Construction equipment would operate as close as 15 to 20 feet from the existing Valley Oaks Apartments to the southwest for a short period, but would be setback more than 50 feet from other adjacent uses to the west, north, east, and south. Due to the proximity of existing apartments to the southwest, construction -related noise increases could be significant periodically, and implementation of the following measure, in conjunction with enforcement of time restrictions and noise level standards contained in the Town Noise Ordinance, will be required to reduce temporary noise impacts to a less - than -significant level: MITIGATION MEASURE 12: To minimize construction noise impacts on existing adjacent residences to the west, existing boundary fencing shall be retained throughout the noisier earthmoving phase of construction or proposed fencing along this boundary shall be constructed as early as possible (prior to project grading activities if feasible). To maximize the fence's noise attenuation effects, DECEMBER,2010 20 MITIGATED NEGATIVE DECLARATION — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL, ROAD proposed fencing shall be solid with no gaps, cracks, or openings (e.g., high quality air -tight tongue -and -groove, board and batten, or shiplap design). MITIGATION MONITORING: The Building and Planning Divisions of the Community Development Department will be responsible for ensuring proper implementation of this measure prior to and during construction. Impacts associated with groundborne vibration and noise are typically less than significant for most types of construction activities (i.e. vibration levels generated by most types of construction equipment would not exceed threshold levels for cosmetic damage to structures). However, operation of impact or vibration pile drivers or large truck -mounted compactors can generate vibration levels that would disturb neighbors and could result in cosmetic damage to adjacent structures at distances of less than 50 feet. Operation of such equipment as part of project construction would not be required. Therefore, impacts associated with groundborne vibration and noise are expected to be less than significant. Operational Noise. Sources of noise associated with the proposed retail commercial use would include delivery trucks and associated loading and unloading activities, parking cars, garbage trucks and refuse bins as well as rooftop air conditioning and heating units. The proposed loading space would be located on the north end of the parking lot adjacent to Placer Oaks Road, approximately 100 feet from the office building to the north, 280 feet from the closest existing residence to the northwest, 50 feet from the closest proposed single-family residence to the west, and approximately 10 feet from the closest senior apartment to the east. Noise levels due to loading activities would be variable, but typically do not exceed 60 dBA (Leq) at 100 feet for loading activities on loading docks. Since small retail uses in proposed commercial buildings would not require loading docks and only small delivery trucks are expected, noise from loading/unloading activities would be less and not expected to generate exceed existing or future ambient noise levels. Two trash enclosures are proposed, one at the northwest corner of Building One (adjacent to Placer Oaks Road) and a second at the southwest corner of Building Two (adjacent to Blossom Hill Road). The northerly trash enclosure would be located directly below the proposed senior apartment Unit 1, while both enclosures would be approximately 60 feet from the closest single-family residences to the west. Section 16.20.055 of the Noise Ordinance prohibits refuse collection with a refuse collection vehicle between the hours of 6:00 p.m. and 6:00 a.m. in a residential zone. Since the western portion of the project site is located in a residential zone, these time restrictions on refuse collection would not apply to the commercial portion of the project and it is possible that disturbance of residents living in the westernmost senior apartments and easternmost single-family homes would be subject to disturbance in the early morning hours from trash collection activities, a potentially significant impact. To ensure that such noise disturbance is avoided, the following measure shall be required to reduce potential operational noise impacts to less than significant: MITIGATION MEASURE 13: As a condition of project approval, the Town will require the commercial -related trash collection activities to comply with Section 16.20.055 of the Noise Ordinance, which prohibits refuse collection with a refuse collection vehicle between the hours of 6:00 p.m. and 6:00 a.m. in a residential zone. MITIGATION MONITORING: The Planning Division of the Community Development Department will be responsible for ensuring this condition is included as part of the Planned Development. DECEMBER,2010 21 MITIGATED NEGATIVE DECLARATION — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD When the Los Gatos Noise Ordinance noise limits are applied to the project site, the ordinance noise limits would be 55 dBA from 6 a.m. to 1 p.m., 59 dBA from 1 p.m. to 10 p.m., and 48 dBA fiom 10 p.m. to 6 a.m. Project operations, including rooftop equipment and loading activities, will be required to comply with these ordinance noise limits. Noise abatement measures (e.g., use of quieter equipment, provision of equipment enclosures or sound barriers, or use of parapet roof design) will be incorporated into the project as required in order to comply with these noise limits. Project -related traffic increases on Placer Oaks Road would also result in long-term noise increases along this roadway. Based on traffic volumes presented in Section 16, Transportation and Traffic, project - related traffic increases along existing neighborhood streets would increase noise levels by less than 1 dBA, which would be less than significant. In general, noise increases of 3 dBA are barely perceptible to most people. When traffic increases on Placer Oaks Road due to this project are considered with estimated traffic increases from the proposed Placer Oaks project, cumulative traffic increases on Placer Oaks Road would be approximately 1 dBA, also a less -than -significant noise increase. Noise Compatibility of Proposed Use. A detailed noise study was prepared by Edward L. Pack Associates, Inc. (ELPA) in October 2010, and this report is included in Attachment 7 of the Initial Study. As part of this study, a continuous, 24-hour noise measurement was taken at two locations on the site: 128 feet from the centerline of Los Gatos Boulevard and 50 feet from the centerline of Blossom Hill Road. The results of these measurements indicate that noise levels at 64 dB (DNL) at 128 feet from the Los Gatos Boulevard centerline (daytime Leg of 60 to 65 dBA and nighttime Leg of 50 to 58 dBA) and 65 dB (DNL) at 50 feet from the Blossom Hill Road centerline (daytime Len of 60 to 66 dBA and nighttime Len of 47 to 58 dBA). Noise exposure of proposed uses are estimated to be as follows: • Senior apartments would be exposed to noise levels of 67 dB (DNL) at the closest balconies and exterior walls. Under future traffic conditions, the noise exposure is expected to increase to 68 dB (DNL). ■ Single-family homes located adjacent to Blossom Hill Road would be exposed to noise levels of up to 64 dB (DNL) on the first floor and 65 dB (DNL) on the upper floor. Under future traffic conditions, the noise exposure is expected to increase to 65 dB (DNL) and 66 dBA (DNL), respectively. • Balconies of single-family homes located closest to Blossom Hill Road (79 feet from the centerline) would be exposed to noise levels of 67 dB (DNL). Under future traffic conditions, the noise exposure is expected to increase to 68 dB (DNL). • The common open space area in the residential portion of the project would be subject to noise levels of 47 to 50 dB (DNL) or 45 to 48 dBA (Leq(24)) under existing conditions and 48 to 51 dB (DNL) or 46 to 49 dBA (Leq(24)) under future traffic conditions. ■ Exterior noise exposures in the patio of Building 1 (northerly building) would be subject to noise levels of 53 to 56 dBA (Leq(24)) under existing conditions and 54 to 57 dBA (Leq(24)) under future traffic conditions. ■ Exterior noise exposures in the patio of Building 2 (southerly building) would be subject to noise levels of 51 to 55 dBA (Leq(24)) under existing conditions and 52 to 56 dBA (Leq(24)) under future traffic conditions. To determine noise compatibility of the proposed use, noise levels at the site were compared to the Town's outdoor noise goals specified in the Noise Element of the General Plan for new commercial and residential developments. Policy N.P.1.7 of the Noise Element specifies outdoor noise limits of 70 dBA DECEMBER, 2010 22 MITIGATED NEGATIVE DECLARATION — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD (Leq(24) or Len averaged over 24 hours) for commercial uses, 55 dBA (4424I) for open space (developed park) uses, and 55 dB (DNL) for residential uses, stating that these noise limits represent the "long range community aspirations" and acknowledging that such goals may not be attainable at this time. When existing and future noise exposures at proposed uses are compared to these noise goals, proposed senior apartments and single-family homes would be subject to existing and future noise levels that exceed the Town's 55-dB (DNL) noise goal. The proposed common open space park in the residential portion of the site would be subject to existing and future noise levels that would not exceed the Town's 55-dBA (Leq(24)) noise goal for open space (developed parks) areas. The proposed commercial buildings would be subject to existing and future noise levels that would not exceed the Town's 70-dBA (Leq(24)) noise goal for commercial uses. The Town Noise Element does not specify a noise goal that could appropriately be applied to the proposed patios on the west side of both commercial buildings, but if the commercial noise goal were to be applied, existing and future noise levels at the proposed patios would meet the 70-dBA (Leq(24)) noise goal. Although the Town's 55-dB (DNL) residential noise goal would not be met at proposed residential uses, the Town's Noise Element (Policy 9) states that these noise limits represent the "long range community aspirations" and acknowledges that such goals may not be attainable at this time. Such goals may be more appropriate for residential neighborhoods that are located away from major noise sources (such as freeways or arterial roadways). In areas where the Town's noise goal cannot be met, the Town also uses the land use compatibility noise guidelines included in the Town's Noise Element as a criterion for defining significance of a noise impact under CEQA. These noise guidelines define noise limits as follows: ■ Single-family Residential Uses: normally acceptable up to 60 dB (DNL) in exterior living areas (yards and common open space); conditionally acceptable between 55 and 70 dB (DNL); normally unacceptable between 70 and 75 dB (DNL); and clearly unacceptable above 75 dB (DNL).2 • Multi -family Residential Uses: normally acceptable up to 65 dB (DNL) in exterior areas (balconies); conditionally acceptable between 60 and 70 dB (DNL); normally unacceptable between 70 and 75 dB (DNL); and clearly unacceptable above 75 dB (DNL). • Commercial Uses: normally acceptable up to 70 dB (DNL); conditionally acceptable between 55 and 70 dB (DNL); normally unacceptable between 70 and 75 dB (DNL); and clearly unacceptable above 75 dB (DNL). Noise levels up to 70 dB (DNL) are considered acceptable for commercial uses. In addition, Title 24, Part 2 of the California Code of Regulations contains requirements for construction of new hotels, motels, apartment houses, and dwellings other than detached single-family dwellings intended to limit the extent of noise transmitted into habitable spaces. For limiting noise transmitted between adjacent dwelling units, Title 24 standards specify the extent to which walls, doors, and floor - ceiling assemblies must block or absorb sound, requiring a Sound Transmissions Class (STC) rating of 50 or higher in common walls and floor/ceiling assemblies. As design details for the interior partitions of the project are not currently available, an evaluation of the interior partitions has not been made. For limiting noise from exterior sources, Title 24 specifies an interior standard of 45 dB (CNEL or DNL) in any habitable room with all doors and windows closed and requires an acoustical analysis demonstrating how dwelling units have been designed to meet this interior standard where such units are proposed in 2 Under Normally Acceptable conditions, no special noise insulation requirements are needed. Under Conditionally Acceptable, a detailed noise analysis and needed noise attenuation design measures are required, but conventional construction, but with closed windows and fresh air supply systems or air conditioning will normally suffice. Where noise levels are considered Normally Unacceptable, new construction is generally discouraged but if it proceeds, a detailed noise study and needed noise attenuation design measures are required. DECEMBER,2010 23 MITIGATED NEGATIVE DECLARATION — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD areas subject to noise levels greater than 60 dB (CNEL or DNL). The ELPA noise study fulfills the Title 24 requirement of an acoustical study. When compared to the above land use compatibility noise guidelines and Title 24, project consistency would be as follows: ■ Senior Apartments: Noise levels at balconies of the four units facing Los Gatos Boulevard (Units 1 to 4) would exceed the 65 dB (DNL) noise guideline for multi -family residential uses by 3 dB and apartment interiors exceed the Title 24 requirement by 8 dB, a significant noise impact. ■ Single-family Homes: Exterior noise levels at single-family residences located closest to Blossom Hill Road would exceed the 60 dB (DNL) noise guideline for single-family residential uses by up to 3 dB, a significant noise impact. • Common Open Space Area: Noise levels in the common open space area in the residential portion of the project would not exceed the Town's 55-dBA (Leq(24)) for open space (developed park) uses, a less -than -significant noise impact. • Patios of Buildings 1 and 2: Noise levels at both patios would not exceed the Town's 70-dBA (Leq(240 noise goal for commercial uses, a less -than -significant noise impact. To reduce the significant noise impacts identified above for the senior apartments and single-family residences, the following noise attenuation measures will be incorporated into the project design to ensure that acceptable interior noise levels are achieved, reducing identified impacts to a less -than - significant level: MITIGATION MEASURE 14: To meet the Town's 55-dB (DNL) residential noise goal, balconies and decks shall be completely enclosed so that these spaces were no longer exterior spaces. If such a design is undesirable, the following design requirements shall be implemented to achieve Town - recommended exterior noise guidelines in usable outdoor spaces on proposed senior apartments and single-family residences: a. To achieve compliance with the Town's 65-dB (DNL) exterior noise guideline at proposed senior apartments, 42-inch high acoustically -effective railings shall be constructed on the balconies of Units 1 to 4 along Los Gatos Boulevard. The balcony railing height is in reference to the nearest balcony floor elevation. To achieve an acoustically -effective balcony railing, it must be constructed air -tight (i.e. without cracks, gaps, or other openings) and must provide for long-term durability, including the balcony floor. The railings can be constructed of masonry, wood, concrete, stucco, metal or a combination thereof, and must have minimum surface weight of 1.5 pound per square foot. If wood fencing is used, homogenous sheet materials are preferable to conventional wood fencing as the latter has a tendency to warp and form openings with age. However, high quality, air -tight tongue -and -groove, board and batten, or shiplap construction can be used, provided that the construction is air -tight and the minimum surface weight is met. Translucent materials, such as glass, Lexan, or Plexiglas, may be incorporated into the barriers to provide for light and views, however, they must have a minimum thickness of 3/16 inches to meet the minimum surface weight requirement. Downspouts and scuppers are preferable over sheet draining. All connections with posts, pilasters, and the building shells must be sealed air -tight. No openings are permitted between the upper railing components and the balcony floor. DECEMBER, 2010 24 MITIGATED NEGATIVE DECLARATION— 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD b. To achieve compliance with the Town's 60-dB (DNL) exterior noise guideline at side and rear yards of proposed single-family residences, six-foot high acoustically -effective barriers between proposed homes on Lots 1 through 5 and along the west side of Lot 5, terminating near the garage (see Figure 1 of Attachment 7 for the locations of the recommended noise - control barriers). The barriers shall connect air -tight to the sides of the homes. The barrier height is in reference to the nearest building pad elevation. To achieve an acoustically -effective barrier, it must be constructed air -tight, i.e., without cracks, gaps or other openings, and must provide for long term durability. The barriers can be constructed of masonry, wood, concrete, stucco, metal, earth berm or a combination thereof, and must have a minimum surface weight of 2.5 pounds per square foot. If wood fencing is used, homogeneous sheet materials are preferable to conventional wood fencing as the latter has a tendency to warp and form openings with age. However, high quality, air- tight tongue -and -groove, board and batten or shiplap construction can be used, provided that the construction is air -tight and the minimum surface weight is met. Gates may be incorporated into the barriers; however, they must meet the minimum surface weight and height requirements and must fit tight when closed. Astragals or stops shall be used over the hinge jamb and closure jamb gaps. A gap under a gate may be no more than 1-inch high. All connections with posts, pilasters and the building shell must be sealed air -tight. No openings are permitted between the upper barrier components and the ground. MITIGATION MEASURE 15: To achieve the acceptable interior noise levels of 45 dB (DNL) at proposed senior apartments (Title 24) and single-family residences, the following noise control measures shall be incorporated into the project design: a. All windows and glass doors of living spaces that are proposed within 270 feet of the Los Gatos Boulevard centerline and with a direct or side view of the roadway (Units 1 to 5) shall be kept closed at all times. All windows and glass doors on these units shall have a minimum Sound Transmission Class (STC) rating of 28. Mechanical ventilation shall be provided in these units. b. All windows and glass doors of living spaces that are proposed within 120 feet of the Blossom Hill Road centerline and with a direct or side view of the roadway (Lots 1 to 5) shall be kept closed at all times. All windows and glass doors on these units shall have a minimum Sound Transmission Class (STC) rating of 28. Mechanical ventilation shall be provided in these units. When windows and doors are maintained closed for noise control, some type of mechanical ventilation to assure a habitable environment must be provided. The mechanical ventilation requirements are specified in the Uniform Building Code (UBC) and described in Appendix B of the ELPA study, which is included as Attachment 7 of the Initial Study. The windows that are specified to be maintained closed are to be operable, as the requirement does not imply a "fixed" condition. All other windows of the project and all bathroom windows may have any type of glazing and may be kept opened as desired unless the bathroom is an integral part of a living space without a closeable door. In addition to the required STC ratings, the windows and doors shall be installed in an acoustically -effective manner. To achieve an acoustically -effective window construction, the sliding window panels must form an air -tight seal when in the closed position and the window frames must be caulked to the wall opening around their entire perimeter with the non -hardening DECEMBER, 2010 25 MITIGATED NEGATIVE DECLARATION — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD caulking compound to prevent sound infiltration. Exterior doors must seal air -tight around the full perimeter when in the closed position, The acoustical test report of all sound -rated windows and doors should be reviewed by a qualified acoustician to ensure that the chosen windows and doors will be adequately reduce traffic noise to acceptable levels. Many dual -pane windows and glass door assemblies have inherent noise reduction problems in the traffic noise frequency spectrum due to resonance that occurs within the air space between the window lites, and the noise reduction capabilities vary from manufacturer to manufacturer. MITIGATION MONITORING: The Building and Planning Divisions of the Community Development Department will be responsible for ensuring these noise abatement measures are properly incorporated into the project design. 13. Population and Housing: A detailed evaluation of the population and housing conditions in the San Francisco Bay area, including the Town of Los Gatos, has been prepared by the Association of Bay Area Governments (ABAG) as part of its Projections 2009 assessment of population, housing, and employment for the region. This ABAG report serves as a basis for the formulation of the Town's 2007 — 2014 Housing Element. ABAG's Projections 2001 provided the background data used for the Town's 2002 — 2007 Housing Element. The 2007 — 2014 Housing Element and its supporting technical analyses are incorporated herein by reference. As discussed in the Housing Element, regional governments are required by State law to estimate and allocate the number of housing units needed among each member community. This estimated number of housing units is called the Regional Housing Needs Allocation (RHNA) and is broken down by income level with the goal of fairly distributing affordable housing throughout the region. The Town of Los Gatos is located in Santa Clara County, one of the nine Bay Area counties that are represented by ABAG. ABAG estimates the total RHNA for Los Gatos to be 562 housing units for the planning period starting July 1, 2007 and ending June 30, 2014. The RHNA number presented in the Housing Element was adjusted to account for residential units built, under construction, or approved since 2007. The adjusted RHNA is currently 521 dwelling units. The technical study prepared in support of the Housing Element includes an inventory and analysis of land available for potential use in residential development, either entirely as residential or as part of a mixed -use project. The study identifies seven sites, including the proposed project site (Swanson Ford property), as potential locations for new residential uses. It should be noted that most of the candidate sites have been previously developed with other uses and would be converted to residential or mixed uses. The technical study indicates that the seven sites have a realistic development capacity of 611 dwelling units. This capacity exceeds the ABAG-identified RHNA, as adjusted, by 90 units. Consequently, the Town has sufficient available sites to meet its share of allocated regional housing demand for the planning period of 2007 to 2014. The proposed mixed -use development of the project site includes residential use that is incorporated into the residential land inventory used for the 2007 — 2014 Housing Element. The Element's technical study provides a discussion of the residential uses planned for this site (Swanson Ford) and recognizes that the proposed project encompasses development of six senior apartments. To the extent that the proposed project contributes additional residential uses to the anticipated housing needs within the community through 2014, the project would be consistent with the level of growth planned for Los Gatos through 2014. DECEMBER, 2010 26 MITIGATED NEGATIVE DECLARATION— 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Since the proposed project would replace an auto dealership with 23,267 s.f. of retail commercial space, six senior apartments, and 29 single-family homes, the project would increase the Town's population. The proposed project could generate approximately 80 additional residents. The project's addition of 80 persons would represent a 0.3% increase over the Town's current population of 28,810, as indicated in the technical study for the Housing Element. ABAG projects that Los Gatos' population will increase to 30,000 by 2020, a growth rate of 1 percent that would be consistent with the growth rate of the past 30 years. Such increases in population would not represent a significant increase in local or regional population. The project would not be considered growth -inducing, since the project would involve redevelopment of an existing developed parcel and the project would not extend roads or infrastructure to any adjacent properties. The General Plan encourages redevelopment of the project area since it designates the project site and surrounding properties as "mixed use commercial." Although the project helps to fulfill the Town's desire for redevelopment of this area as indicated by the General Plan, the project is only partially consistent with the economic -related General Plan and Los Gatos Boulevard Plan goals and policies for the site. 14. Public Services: Services are currently provided to the project site as well as to adjacent commercial and residential uses. No significant increase in demand on public safety services is expected to be required for the proposed project since services were previously provided to the former auto dealership use on the site. The Santa Clara County Fire Department has reviewed the project plans for site access and water supply, and the project will be required to meet Department requirements for minimum fire flow, automatic fire sprinklers, hydrant spacing/location (including three private on -site hydrants), building access requirements, etc. The project will be required to install an automatic fire sprinkler system, appropriate fire lane marking, and fire department emergency access key lock box. Adequate fire apparatus (engine) access will need to be provided on any access roads, which includes 20-foot pavement width, a minimum turning radius of 36 feet outside and 23 feet inside, and a maximum slope of 15 percent. The Fire Department also requires potable water supplies to be protected from contamination caused by fire protection water supplies. The proposed plan will be subject to formal plan review by the Santa Clara County Fire Department to determine compliance with adopted model codes. The project would increase Town population by 0.5%, which would incrementally increase demand for recreational facilities. The project's potential impact on the demand for recreational facilities is discussed in Section 15, Recreation, below. Based upon population growth estimates in Projections 2009 from the Association of Bay Area Governments (ABAG), the project would add approximately 11 new students to the Los Gatos Union School District and Los Gatos -Saratoga High School District. The Los Gatos Union School District has advised the Town that the development of 47 new residential units under the previous plan would generate approximately 20 new students for the elementary and middle schools in Los Gatos. Under the revised project design of 29 residential units, the project would be expected to generate 12 new students. The District is currently operating at or near capacity at all of the downtown schools and proposed development will result in the need for new classrooms. The District proposes to use funds from an approved bond initiative (Measure E) to fund new facilities that would accommodate some of the new growth in student population. DECEMBER,2010 27 MITIGATED NEGATIVE DECLARATION— 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM IILL ROAD Project students would attend Louise Van Meter Elementary School, Fisher Middle School, and Los Gatos High School. To offset potential additional service costs for enrolling new students from the proposed project, the Los Gatos Union School District and Los Gatos -Saratoga High School District will charge the project applicant impact fees based on the size of new homes (per square foot basis) and by supplemental parcel taxes on the new residential parcels. Payment of impact fees and supplemental taxes would mitigate the project's impacts on school services to a less -than -significant level. 15. Recreation: The proposed net addition of 29 single-family residences and six senior apartments would increase local population, and thereby incrementally increase demand for recreational facilities. A common open space area or park is proposed in the residential portion of the project near the western project boundary. The common open space area would be decomposed granite, with an existing redwood tree to be retained along the western project boundary and a seating area to be provided in this area. This common open space is located adjacent to the western project boundary, and existing residential uses are located adjacent to this boundary (see Section 12, Noise, for more discussion of potential noise impacts associated with this park). Private open space associated with the 29 single-family residences would be limited to rear yards and sideyards for all units; Lots 1 through 5 and 15 through 19 would also have small front yards along Blossom Hill Road and Placer Oaks Road, respectively. No private open space is proposed for senior apartments. However, outdoor dining patios for ground floor commercial tenants are proposed adjacent to both commercial buildings where senior apartments would be located. A pedestrian corridor is proposed to connect the residential and commercial components of the project, which would enable senior apartment residents to access the common open space on the western portion of the site. While the provision of a small common open space area is relatively limited for the total number of single-family and apartment units, the project is proposed as a Planned Development, which allows for Town discretion in the evaluation and approval of project elements. The Town has no specific open space standards to determine adequacy of proposed open space for the number of residential units proposed. Nearby recreational facilities include Louise Van Meter Elementary School (one-half mile to the south), Los Gatos High School (one mile to the southwest), and Vasona Park (one-third mile to the west). The project's incremental increase in demand for recreational facilities is considered to be less than significant given the project's proximity to existing recreational facilities, and proposed provision of common open space on the project site. 16. Transportation and Traffic: The Town's Traffic Impact Policy (Resolution 1991-174) requires preparation of a detailed traffic study for any project with the potential to generate 20 or more additional AM or PM peak hour trips. The Town's contract transportation engineering firm, TJKM Transportation Consultants, has completed an assessment of potential traffic impacts resulting from the proposed project. The traffic impact study is on file at the Town Community Development Department. Trip Generation. Based on the estimated trip generation for proposed uses (29 single-family homes, six senior apartments, and 23,267s.f. of specialty retail), the project would generate approximately 1,647 average daily trips, with 194 AM peak hour trips and 146 PM peak hour trips. According to TJKM, when trip generation from the former auto dealership is considered, the proposed mixed -use project would result in a net increase of 955 daily trips, with 151 AM peak hour trips and 92 PM peak hour trips. Project -related Traffic Impacts. TJKM evaluated the project's impact at the following intersections: Los Gatos Boulevard/ Los Gatos -Almaden Road, Los Gatos Boulevard/Blossom Hill Road, Los Gatos Boulevard/Shannon Road/Roberts Road, Blossom Hill Road/Roberts Road, and Blossom Hill DECEMBER,2010 28 MITIGATED NEGATIVE DECLARATION — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Road/Camellia Terrace. Under Existing Conditions, all study intersections operate acceptably during the AM and PM peak hours, LOS D or better. With 13 approved projects identified in the project area (Existing Plus Background Conditions), these intersections would continue to operate acceptably (LOS D or better) during the AM and PM peak hours, with a negligible increase in delay (less than two seconds of average delay). With the proposed project (Background Plus Project Conditions), all study intersections are expected to continue operating at essentially the same level of service as Existing Plus Background Conditions (LOS D or better) during the AM and PM peak hours. The TJKM study also concluded that the there is sufficient roadway capacity on the Los Gatos Boulevard and Blossom Hill Road study segments to accommodate proposed project trips. With addition of traffic generated by approved projects and the proposed project, study segments would operate within acceptable capacity limits (LOS D). Under Existing Conditions, TJKM found that the eastbound left -turn lane on Blossom Hill Road at Los Gatos Boulevard is inadequate for queuing. Addition of traffic generated by approved projects and the proposed project (Background Plus Project Conditions) would significantly increase this left -turn movement queue. However, implementation of either of the following turning lane improvements will reduce this impact to a less -than -significant level: MITIGATION MEASURE 16: A second eastbound left -turn lane shall be added on Blossom Hill Road and both left -turn storage lanes shall be extended to 250 feet (per lane) to accommodate future traffic levels OR The applicant shall contribute to the addition of a second eastbound left -turn lane at the Los Gatos Boulevard/Blossom Hill Road intersection and lengthening both left -turn lanes to 250 feet for its incremental share of impact as determined by the Town Engineer. MITIGATION MONITORING: The Building and Planning Divisions of the Community Development and the Engineering Division of the Parks and Public Works Departments will be responsible for ensuring these measures are implemented prior to project completion. The proposed project is estimated to generate approximately 10 trips during the highest peak hour (PM peak hour) on Placer Oaks Road (i.e. one car every six minutes). Such an increase should not be noticeable and TJKM concluded that these additional trips are not expected to cause a significant traffic impact. Traffic Safety. The proposed project is expected to have little or no impact on the collision rate (or safety) at study intersections or study road segments. Based on the 2004 Accident Data for California State Highways, the average statewide accident rate is 0.58 accidents per million vehicles for four - legged, suburban signalized intersections and 0.34 accidents per million vehicles for suburban, unsignalized intersections. Based on collision reports obtained from Town staff for the last three years (January 1, 2006 to December 31, 2008) and existing peak hour turning movement counts, the collision rates for all study intersections are below the statewide average collision rates. Therefore, the proposed project is not expected to have a significant impact on future collision rates. Vehicular Access. Currently, the project site is accessed via three driveways on Blossom Hill Road and five driveways on Placer Oaks Road. The all -way access closest to an intersection is located on Blossom Hill Road, approximately 180 feet west of the stop line of the Los Gatos Boulevard/Blossom Hill Road intersection. Additionally, there is a right-in/right-out access for the site on Los Gatos Boulevard, and it is located approximately mid -block between Placer Oaks Road. Project implementation would reduce the total number of driveways from ten to four: two on Placer Oaks Road, one on Los Gatos Boulevard, and DECEMBER,2010 29 MITIGATED NEGATIVE DECLARATION— 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD one on Blossom Hill Road. Although the proposed all -way access on Blossom Hill Road would be located approximately 260 feet from the curb line of the Los Gatos Boulevard/Blossom Hill Road intersection, this proposed location would meet corner clearance distance requirements and would not interfere with.the dual, 250-foot long left -turn lanes required on eastbound Blossom Hill Road under Mitigation Measure #16. Therefore, no significant traffic safety impacts would be associated with the proposed driveway configuration. Pedestrian, Bicycle, and Transit Access. At present, there are sidewalks along both sides of Los Gatos Boulevard and Blossom Hill Road in the project vicinity and these sidewalks would be sufficient to handle project -related pedestrian traffic. In addition, pedestrian connections (paseos) are proposed to extend between project homes and the commercial uses to facilitate pedestrian access between uses on the project site. The Los Gatos School District has expressed concerns about the safe travel of both cars and children across the Los Gatos Boulevard/Blossom Hill Road intersection, both before and after school. Based on the accident history of this intersection described. above, this intersection is not considered unsafe for pedestrians. However, the potential increase of up to 20 students crossing this street due to the project is considered a potentially significant safety concern. As a condition of project approval, the Town will require the project to complete improvements at this intersection such as modifying the wheelchair ramps (ADA), pedestrian refuge islands (pork -chop islands), and adding bicycle lane stripes at intersection approaches, which will enhance pedestrian and bicycle safety. In addition, the following measure will be required to further reduce safety concerns to a less -than - significant level: MITIGATION MEASURE 17: The project will be required to modify their fair share of the Blossom Hill Road/Los Gatos Boulevard intersection and upgrade existing traffic signal to .current Town standards including but not limited to ADA ramps, pedestrian islands, signing, striping, vehicular signal heads, pedestrian signals, video detection, safety lighting, as directed by Town Engineer, MITIGATION MONITORING: The Engineering Division of the Parks and Public Works Department will be responsible for ensuring that these improvements are reflected in project plans and the Building Division of the Community Development Department will be responsible for ensuring that these improvements are properly constructed. Currently, there are striped bicycle lanes along Los Gatos Boulevard and Blossom Hill Road in the project vicinity. The project is not expected to generate a significant volume of bicycle traffic, and therefore, no significant impacts on roadway or bike lane capacities are expected. Based on field observations, Santa Clara Valley Transportation Authority (VTA) Bus Line 49 runs along Los Gatos Boulevard in the vicinity of the site. The nearest bus stops for Line 49 are located to the north of the project site on both sides of Los Gatos Boulevard. The project is not expected to have a significant impact on transit ridership levels. The VTA has provided the Town with design recommendations that provide for enhanced pedestrian and bicycle accommodations in the project vicinity. The requested facilities include bicycle parking for the mixed -use condominium and commercial portions of the project. VTA supports bicycling as an important transportation mode and thus recommends inclusion of conveniently located bicycle parking for the project. Bicycle parking facilities can include bicycle lockers for long-term parking and bicycle racks for short-term parking. VTA's Bicycle Technical Guidelines provide guidance for estimating supply, siting and design for bicycle parking facilities. Parking. The Town Code would require provision of one parking space for every 300 s.f. of retail commercial space (or 3.3 spaces for every 1,000 s.f.), one and one-half spaces per unit in multiple -unit DECEMBER,2010 30 MITIGATED NEGATIVE DECLARATION— 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD dwellings, and two spaces for each single-family residential unit. On the eastern commercial portion of the site, 104 parking spaces are proposed for retail commercial uses (4.4 spaces per 1,000 s.f.), which would exceed Town parking requirements. Six spaces are proposed to be provided for senior housing (1 space per unit), which would be less than the required one and one-half spaces per unit. However, the age restrictions (seniors only) would minimize parking demand of proposed apartments and the shared nature of parking with commercial uses would minimize potential parking shortages. Therefore, no significant impacts from this shortfall of parking spaces are expected. On the western, residential portion of the site, 58 covered parking spaces (two enclosed garage spaces in each unit) and 16 guest spaces would be provided, which would exceed Town parking requirements. Cumulative Impacts. TJKM identifies 10 pending projects that could contribute a total of 293 AM peak hour trips and 557 PM peak hour trips onto the Los Gatos street network. When traffic from pending projects are added (Background Plus Project Plus Pending Conditions), study intersections are expected to operate acceptably and at essentially the same level of service as under Background Plus Project Conditions, LOS D or better during the AM and PM peak hours. However, southbound left -turn storage at the Los Gatos Boulevard/Blossom Hill Road would not be adequate to accommodate future cumulative traffic increases. Therefore, the proposed project would contribute incrementally to the future need to increase storage capacity for this movement. TJKM recommends that the Town consider increasing southbound left -turn storage capacity as part of future capital improvement projects. This could be accomplished by reconfiguring the median of the southbound approach to accommodate the extension of the existing second left -turn lane to 275 feet. To reduce the project's contribution to this cumulative traffic congestion problem to a less -than -significant level, the following measure containing two options shall be required: MITIGATION MEASURE 18: The applicant shall modify the Los Gatos Boulevard/Blossom Hill Road intersection to add southbound left -turn storage capacity by increasing the second left -turn lane to 275 feet OR The applicant shall contribute to increased southbound left -turn storage capacity at the Los Gatos Boulevard/Blossom Hill Road intersection for its incremental share of impact as determined by the Town Engineer. MITIGATION MONITORING: The Community Development and Engineering Division of the Parks and Public Works Departments will be responsible for ensuring this measure is implemented prior to project completion. There are six auto dealership sites located on Los Gatos Boulevard and Blossom Hill Road and four of these are currently vacant (former Los Gatos Chevrolet at15600 Los Gatos Boulevard, Swanson Ford at 16005 Los Gatos Boulevard, South Bay Honda at 6213 Los Gatos Boulevard, and Bentley Silicon Valley at 620 Blossom Hill Road). TJKM examined two future cumulative traffic scenarios that could result if these currently vacant auto dealerships (other than the proposed project) were to either: (1) become re- occupied with the previously -approved auto dealership use; or (2) redevelop into other uses (assumptions developed by Town staff). Under the first scenario, re -occupation of the three vacant auto dealerships could add 111 AM peak hour trips and 189 PM peak hour trips. With such traffic increases, study intersections would operate acceptably and at essentially the same level of service as under Background Plus Project Plus Pending Conditions, LOS D or better during the AM and PM peak hours. Under the second scenario, redevelopment of the three vacant auto dealerships could add 1,383 AM peak hour trips and 584 PM peak hour trips. With such traffic increases, study intersections would operate at DECEMBER, 2010 31 MITIGATED NEGATIVE DECLARATION — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD essentially the same level of service as under Background Plus Project Plus Pending Conditions (LOS D or better during the AM and PM peak hours) with one exception. The Los Gatos Boulevard/Blossom Hill Road intersection would operate unacceptably at LOS E during the AM peak hour, a potentially significant cumulative impact. However, this intersection would operate acceptably (LOS D during the AM peak hour) with addition of a second eastbound left -turn lane. This improvement is already identified above and will be required as part of the proposed project. Therefore, this cumulative impact would not be cumulatively considerable with implementation of the above project -related Mitigation Measure # 16. 17. Utilities and Service Systems: Utilities are currently provided to the project site. The proposed building would be required to connect to the existing water and sewer lines located on or adjacent to the site. Project development would also include construction of storm drainage facilities (see Section 9, Hydrology and Water Quality). The Fire Department will require provision of an approved, automatic fire sprinkler system in the proposed building. Other utilities (electrical, gas, telephone, cable TV facilities) will be upgraded as necessary. Sewer service to the proposed development is available from a six-inch sewer line in Blossom Hill Road and another six-inch sewer line in Placer Oaks. Due to the size of the development, the District will require the developer to conduct a flow study determining the project's impact to these two lines. Based on the results of this study, the developer may be required to replace the existing sewer line(s) in order to handle the increased sewage flow from the development.Required upgrades would reduce potential impacts on utilities to less than significant. Copies of the Initial Study used to make the above recommendation are on file and available for public inspection during regular business hours at the Town Community Development Department, 110 East Main Street, Los Gatos, California. ate l " Wendie R. Rooney, irector of Community C eloi'r ent DECEMBER,2010 32 INITIAL STUDY 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD LOS GATOS, CALIFORNIA PLANNED DEVELOPMENT APPLICATION PD-07- 145 PREPARED FOR TOWN OF Los GATOS COMMUNITY DEVELOPMENT DEPARTMENT 110 E. MAIN STREET Los GATOS, CA 95030 DECEMBER 2010 PREPARED BY GEIER & GEIER CONSULTING, INC. P.O. Box 5054 BERKELEY, CA 94705-5054 510/644-2535 ATTACHMENT 2 TOWN OF Los GATOS COMMUNITY DEVELOPMENT DEPARTMENT ENVIRONMENTAL CHECKLIST FORM PROJECT INFORMATION PROJECT TITLE: 16005 Los Gatos Boulevard and 625 Blossom Hill Road Planned Development Application PD-07-145 LEAD AGENCY NAME AND ADDRESS: Town of Los Gatos Community Development Department 110 East Main Street Los Gatos, CA 95030 PROPERTY OWNER: CHL Ventures, LP 489 S. El Camino Real San Mateo, CA 94402 GENERAL PLAN DESIGNATION: Mixed Use Commercial PROJECT LOCATION: 16005 Los Gatos Boulevard and 625 Blossom Hill Road (Figure 1) CONTACT PERSON AND PHONE NUMBER: Heather Bradley, 408/354-6806 PROJECT APPLICANT: Kenneth Rodrigues & Partners 445 N. Whisman Road, Suite 200 Mountain View, CA 94043 ZONING: CH, Restricted Highway Commercial PROJECT DESCRIPTION The project applicant is requesting approval to do the following on the ±4.5-acre site (APN 529-16-025 and 529-16-053): • Rezone the project site from CH to CH:PD • Demolish existing auto dealership buildings • Construct 23,267 square feet (s.f.) of retail commercial space • Construct six senior apartments above the retail commercial space • Develop 29 single-family residences A breakdown of land use by area would be as follows: Proposed Use Commercial (23,267 s.f.) and Senior Housing (6 Units, 8,628 s.f.) on 2.0 Acres Areal Extent (Square Feet) Building Landscaping and Parking and Coverage Patio Driveways 23,267 28,405 37,503 Residential Landscaping and Bldg Floor Open Space Area Parking and Driveways Single -Family Residences (29) on 2.4 Acres 35,612 47,588 20,723 DECEMBER,2010 1 PROJECT LOCATION FIGURE 1 016005 LOS GATOS BOULEVARD A NO SCALE N INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD The eastern half of the site (2.0 acres) would be developed with 23,267 s.f. of retail commercial space in two structures. A one-story, retail commercial building (14,216 s,f.) would be located at the southeast corner of the site (adjacent to Los Gatos Boulevard and Blossom Hill Road). Retail commercial space (9,051 s.f.) would also be provided on the first floor of a two-story, mixed -use building proposed in the northeast corner of the site (adjacent to Los Gatos Boulevard and Placer Oaks Road). Proposed commercial uses are expected to include a sit-down restaurant/cafe and retail commercial space. The one- story building would have a maximum height of 25.5 feet from existing grade, while the two-story commercial building would have a maximum height of 35 feet from existing grade. There are two patios proposed on the west side of both commercial buildings, away from both Los Gatos Boulevard and Blossom Hill Road. The second floor of the mixed -use building would be developed with six senior apartments (8,628 s.f.), which would all be designated as Below Market Rate units. Senior residential units would be one- and two -bedroom apartments with one bath. All senior apartments would be age -restricted and for rent. The western half of the site (2.4 acres) would be developed with 29 residential lots. Typical lot size is proposed to be 2,450 s.f. Single-family homes would be constructed on all 29 lots, ranging in size from 2,003 to 2,684 s.f. All residences would be two stories (typically three to five bedrooms, two to three baths) with garage and storage on the ground floor, living and bedrooms on the second floor, and bedroom/bath on the optional third floor loft. The proposed site plan is included as Attachment 1. Access to the two commercial buildings would be provided by three driveways, one located on each adjacent street: Los Gatos Boulevard, Blossom Hill Road, and Placer Oaks Road. These three driveways would be connected on -site by the proposed parking lot west of the commercial buildings. There is one driveway on Placer Oaks Road that would provide direct access to the residential lots. A second driveway would connect the southern part of the residential area to the commercial area parking lot adjoining Blossom Hill Road. The driveway that intersects with the Blossom Hill Road driveway would provide direct access to the commercial parking lot as well as the southerly residential driveway. With the interconnection of the residential and commercial uses on the project site, project residents could also use the site's commercial driveways on Los Gatos Boulevard and Placer Oaks Road to access the residential development. The two residential driveways would be connected by one internal street, Street `C'. Street `C' would range in width from 20 to 25 feet, and the two smaller internal streets, Streets 'A' and `B' would be 20 feet wide. A total of 184 parking spaces would be provided. On the eastern portion of the site where commercial uses are proposed, 104 parking spaces would be provided for retail commercial uses (4,5 spaces per 1,000 s.f.) and six spaces would be provided for senior housing (one space per unit). On the western portion of the site where residential uses are proposed, 58 covered parking spaces would be provided as two enclosed garage spaces in each unit and 16 guest spaces. The commercial parking lot would be separated from residential parking spaces. Project plans also include the installation of landscaping throughout the site as well as pedestrian walkways and hardscape improvements. Landscaping on private lots and common open space in the residential portion of the site would comprise approximately 46 percent of the residential site (47,588 s.f.), while landscaping and patio areas in the commercial portion of the site would cover approximately 32 percent of the commercial site (28,405 s.f.). Overall, landscaping, open space, and patio areas would cover approximately 39 percent of the site (75,993 s.f.). A pedestrian corridor would connect the residential portion of the project to the proposed commercial uses. The decorative walkway would include curved seat walls and a gated entry. DECEMBER,2010 3 INITIAL STUDY 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD SURROUNDING LAND USES AND SETTING The project site is comprised of approximately 4.4 acres located on the west side of Los Gatos Boulevard, extending between its intersections with Blossom Hill Road and Placer Oaks Road. This site forms the northwest corner of the Los Gatos Boulevard/Blossom Hill Road intersection. The project site is bounded by Los Gatos Boulevard on the east, Blossom Hill Road on the south, and Placer Oaks Road on the north. The project site was previously used by the Swanson Ford auto dealership, and is developed with three main buildings, a covered auto detail area, landscaping, and asphalt paving associated with the site's previous use as an auto dealership. There is a narrow strip of landscaping (lawn, shrubs, and some trees) along portions of the site's southwestern, southern and southeastern boundaries. The first building is located in the eastern portion of the project site and was used as an auto showroom, offices, parts department, and service area. The second building is located near the center of the site and includes office and lunch areas, a car wash, and service bays. These two buildings are currently occupied by Akeena Solar. A covered detail structure and outdoor service area are between these two buildings.' The third building is located in the southwest corner of the site and was formerly used for auto painting and detail work; the structure includes offices, a spray booth, and service area. This building is currently vacant. The northwest portion of the site is undeveloped (exposed soil surface) and fenced off. Land uses adjoining the project site include multi -family residential (condominiums and Valley Oaks Apartments located immediately to the west), single family residential and office uses to the north (across Placer Oaks Road), and retail commercial uses to the east, southeast, and south (across Los Gatos Boulevard and Blossom Hill Road). A combination of wood, masonry, and chain link fences extend along the western project boundary. Landscaping and mature trees located along the southwestern project boundary provide moderate to heavy screening between the project site and adjacent multi -family residences located along the southwest project boundary. Access to the site is currently provided by three driveways on Blossom Hill Road and five driveways on Placer Oaks Road. The driveways on Placer Oaks Road provide access to parking areas located along the eastern and northern project boundaries as well as site buildings on the eastern portion of the site. There is one access driveway (right-in/right-out only) on Los Gatos Boulevard, approximately mid -block between Placer Oaks Road and Blossom Hill Road.2 OTHER AGENCIES WHOSE APPROVAL IS REQUIRED In addition to the Town, the BAAQMD will issue a demolition permit to ensure asbestos -containing materials are properly removed and disposed. No other agencies would issue permits or approve financing or participation agreements for this project. There is one three -stage clarifier on the northeast side of the detail area, a second clarifier located west of the third building, 25 underground hydraulic lifts located in service areas of the facility, and five aboveground hydraulic lifts in an outdoor service area located between the first and second buildings. 2 There is one existing driveway cut on Los Gatos Boulevard, but it has a chain across this driveway, precluding its use. DECEMBER,2010 4 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD ENVIRONMENTAL FACTORS POTENTIALLY AFFECTED: The environmental factors checked below would be potentially affected by this project, involving at least one impact that is a "Potentially Significant Impact" as indicated by the checklist on the following pages: Aesthetics Agriculture Resources X Air Quality X Biological Resources X Cultural Resources X Geology/Soils X Hazards & Hazardous Materials Hydrology/Water Quality Land Use/Planning Mineral Resources X Noise Population/Housing Public Services Recreation X Transportation/Traffic Utilities/Service Systems Mandatory Findings of Significance DETERMINATION: (TO BE COMPLETED BY THE LEAD AGENCY) On the basis of this initial evaluation: I find that the proposed project COULD NOT have a significant effect on the environment, and a NEGATIVE DECLARATION will be prepared. X I find that although the proposed project could have a significant effect on the environment, there will not be a significant effect in this case because revisions in the project have been made by or agreed to by the project proponent. A MITIGATED NEGATIVE DECLARATION will be prepared. I find that the proposed project MAY have a significant effect on the environment, and an ENVIRONMENTAL IMPACT REPORT is required. I find that the proposed project MAY have a "potentially significant impact" or "potentially significant unless mitigated" impact on the environment, but at least one effect 1) has been adequately analyzed in an earlier document pursuant to applicable legal standards, and 2) has been addressed by mitigation measures based on the earlier analysis as described on attached sheets. An ENVIRONMENTAL IMPACT REPORT is required, but it must analyze only the effects that remain to be addressed. I find that although the proposed project could have a significant effect on the environment, because all potentially significant effects (a) have been analyzed adequately in an earlier EIR or NEGATIVE DECLARATION pursuant to applicable standards, and (b) have been avoided or mitigated pursuant to that earlier EIR or NEGATIVE DECLARATION, including revisions or mitigation measures that are imposed upon the proposed project, nothing further is required. Wendie R. Roo Director of Communit elopment j---Q DECEMBER, 2010 5 Date la-Ict I O INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD EVALUATION OF ENVIRONMENTAL IMPACTS Issues: Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 1. Aesthetics - Would the project: a) Have a substantial adverse effect on a scenic vista? X b) Substantially damage scenic resources, including, but not limited to, trees, rock outcroppings, and historic buildings within a state scenic highway? X c) Substantially degrade the existing visual character or quality of the site and its surroundings? X d) Create a new source of substantial light or glare which would adversely affect day or nighttime views in the area? X Existing views of the project site consist of single -story commercial buildings previously serving an auto dealership as well as vehicle service facilities. The site also contains extensive parking areas for vehicle display and storage along Los Gatos Boulevard and Blossom Hill Road. Currently, screened chain link fencing obstructs potential views to the center of the site from Placer Oaks Road and Blossom Hill Road. Commercial Development. From Los Gatos Boulevard, the two commercial buildings of the proposed project would be one and two stories high, with a maximum height of approximately 35 feet at the roof peak. Building One would be a two-story structure providing retail uses on the first floor and six senior apartments on the second level. This building would have a maximum height of 35 feet and would be similar in height and bulk to a nearby commercial building on the northwest corner of the Los Gatos Boulevard and Placer Oaks Road intersection. However, the architectural style of Building One would differ from that of the existing commercial structure across Placer Oaks Road. In addition, the proposed building's setback from Los Gatos Boulevard would be slightly less than the adjoining commercial building, 25 feet rather than approximately 30 feet, respectively (including sidewalk in the public right- of-way). Building Two would be a single -story building with a maximum height of 25.5 feet, situated on the southeastern portion of the project site. Building Two would be separated from Building One by the main driveway entrance to the commercial facilities' parking lot, behind both of the commercial structures. Building Two's single -story design would be similar to the single -story Blossom Hill Pavilion commercial complex that is located opposite the project site on the southwest corner of the Los Gatos Boulevard and Blossom Hill Road intersection. The project's site design proposes Building Two setbacks from Los Gatos Boulevard similar to those of Blossom Hill Pavilion. The proposed commercial buildings' single -story and two-story elements would be similar to the retail commercial and office buildings to the north and south of the project site along Los Gatos Boulevard. The proposed project's design would contrast with the Cornerstone and King's Court shopping centers on the east side of Los Gatos Boulevard on either side of Blossom Hill Road. These retail centers consist of single -story commercial buildings with parking facilities located along Los Gatos Boulevard and commercial buildings situated to the rear of the properties, relative to Los Gatos Boulevard. DECEMBER, 2010 6 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Presently, there are views to the Santa Cruz Mountains for pedestrians and motorists traveling southbound along Los Gatos Boulevard and in both directions on Blossom Hill Road. Views of mountain ridgelines from Blossom Hill Road would be to the south and, due to the project site's northerly location, would remain as currently available. Ridgeline views from Los Gatos Boulevard in the project vicinity are generally blocked and filtered by the project site's existing buildings and the Blossom Hill Pavilion structure, respectively. Residential Development. The residential component of the proposed project entails the development of 29 single-family units on the western portion of the project site. Lots 1 through 5 would front the north side of Blossom Hill Road, while Lots 15 through 19 would front along the south side of Placer Oaks Road. The proposed residential units would be two stories in height along the street front. The residential units proposed within the project site could be developed as two-story homes with an option for a third story loft. Access to all garages would be from internal driveways on the project site. Typical front elevations for the units would be 30 feet from existing grade. The proposed two-story units would be consistent with residential development adjoining the project site to the west. Two-story single-family residences (condominiums) adjoin the project site to the northwest on Placer Oaks Road; these residences are part of a residential development that is addressed on Oak Rim Way. An access drive and parking facilities, including uncovered and carport parking spaces, for this residential development immediately adjoin the northwestern perimeter of the project site. Although a masonry wall separates the two properties, the upper stories of the residences proposed on Lots 9 through 14 would overlook the access driveway and parking facilities of the residential development to the west. Similar to the northwestern portion of the project site, two-story single-family residential units are proposed for the southwestern corner of the site. The Valley Oaks Apartments adjoin the subject property to the west along Blossom Hill Road. The apartment buildings are also two-story structures with residents' access along the western property boundary. A portion of the access drive and the carport structure for the Valley Oaks Apartments adjoin the project site near the central western property line. The project plans specify development of residential Lots 1 through 6 in the southwestern corner of the project site. Of these lots, only Lots 5 and 6 would be in proximity to the Valley Oaks property. These two lots are set back from the common property line and separated from the apartment buildings by a proposed driveway and three parking spaces, common open space, and the Lot 5 side yard on the project site. Unlike the northwestern corner of the project site, existing landscaping, including a mature redwood and brush cherry trees, provide substantial screening between the two properties. Most of these trees would be retained in place to preserve the effective screening provided by this landscaping; the proposed landscaping plans would supplement existing landscaping with additional plantings. The development of residential Lots 1 through 5 and Building Two would change the views of the project site from Blossom Hill Road. Current views from this vantage include the walls of existing service buildings, screened fencing of the center site, and expansive parking lots. The five residential units proposed for this part of project site would extend the residential character established by the Valley Oaks Apartments along the north side of Blossom Hill Road from Oak Rim Way close to the Los Gatos Boulevard intersection. The commercial use proposed for Building Two would be consistent with the views of commercial development of the Blossom Hill Pavilion at this intersection. Los Gatos Boulevard Plan. The project site is located within the plan area for the Los Gatos Boulevard Plan. The Plan provides direction and guidelines for overall development and improvements along Los Gatos Boulevard. In addition to the Plan, the Town has adopted the Los Gatos Commercial Design Guidelines, which include specific recommendations for the architectural treatment, organization, and DECEMBER,2010 7 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD mix of buildings and open space in the Los Gatos Boulevard Plan area. The project's consistency with these guidelines is discussed below in Section 10, Land Use and Planning, in Table 3. Architectural Review of Project Plans. The Town retained Cannon Design Group (CDG) to evaluate the project's architectural design and site plan for consistency with Design Standard objectives. In December 2009, CDG provided the Town with a letter report evaluating the architectural design elements of an initial site design.3 The project plans were subsequently revised prior to submittal to the Town. In response to project design revisions, the Town has required additional review of the revised design by CDG to determine the revised project's consistency with Town design guidelines. It should be noted that the revised project site plans include a reduction in the number of residential units from previous proposals and an increase in the total retail space proposed on the project site. The current project design also includes an architectural re -design of the commercial buildings to achieve better integration with surrounding commercial designs. The proposed landscaping, open space, and patio areas were expanded from the previous design. The proposed parking lot area was also expanded to meet the parking requirements for increased retail uses on the project site. In September 2010, CDG provided the Town with a subsequent review of the project's architectural design and site plan. The CDG review identifies issues of concern such as lack of integration between residential and commercial uses, lack of public and private open space, residential building orientation, setbacks along Blossom Hill Road, lack of articulation in residential designs, design treatment for commercial entries on Los Gatos Boulevard and Blossom Hill Road, and location of senior unit garages. The review indicates that the commercial buildings are well designed with visual interest, appropriate details, and window treatments suitable to the architectural style. Comments provided by the CDG report included nine design considerations. The recommendations and comments include the following items: • The design should integrate proposed residential styles with commercial development design • Residential common open space is minimal and public open space is lacking ■ Larger setbacks on Blossom Hill Road, and between residential and commercial uses are needed ■ Home entries should be designed to avoid facing rows of garages across narrow driveway • Front and side elevations of some 3-story units (e.g. French Country Style) would add substantial visual bulk • The proposed alignment of homes on Lots 1 through 5 is inconsistent with orientation of nearby uses ■ Senior housing lacks associated common open space ■ Commercial access from sidewalks would be desirable • Location of garages for senior housing should be reviewed for privacy and security concerns The proposed buildings would introduce new nighttime lighting to the project site. To reduce the potential for disturbance due to nighttime lighting, the project will need to satisfy Town Code Section 29.10.09035, which prohibits the production of direct or reflected glare (such as that produced by floodlight onto any area outside the project boundary). 3 Copies of the CDG reviews dated December 21, 2009 and September 30, 2010 are on file at the Community Development Department, DECEMBER, 2010 8 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Issues (and Supporting Information Sources) 2. Agriculture Resources - Would the project: a) Convert Prime Farmland, Unique Farmland, or Farmland of Statewide Importance (Farmland), as shown on the maps prepared pursuant to the Farmland Mapping and Monitoring Program of the California Resources Agency, to non-agricultural use? b) Conflict with existing zoning for agricultural use, or a Williamson Act contract? c) Involve other changes in the existing environment which, due to their location or nature, could result in conversion of Farmland, to non-agricultural use? Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact The 4.4-acre project site is currently developed with facilities associated with the former auto dealership use. Development of the proposed mixed -use project would replace the remnants of the site's previous commercial use with new residential and retail commercial development. Since the site is not in agricultural use and has no agricultural potential due to its small size, location, and previous use, the project would not adversely affect any existing agricultural resources or operations. Since the properties surrounding the project site are developed with commercial and residential uses, the proposed project would not adversely affect other agricultural properties or result in the conversion of farmland to non- agricultural use. Issues (and Supporting Information Sources) 3. Air Quality - Would the project: a) Conflict with or obstruct implementation of the applicable air quality plan? b) Violate any air quality standard or contribute substantially to an existing or projected air quality violation? c) Result in a cumulatively considerable net increase of any criteria pollutant for which the project region is non - attainment under an applicable federal or state ambient air quality standard (including releasing emissions, which exceed quantitative thresholds for ozone precursors)? d) Expose sensitive receptors to substantial pollutant concentrations? e) Create objectionable odors affecting a substantial number of people? Air Quality Planning. The San Francisco Bay Area Air Basin is classified by the Bay Area Air Quality Management District (BAAQMD) as non -attainment for ozone and inhalable particulates (PM10). To e address these exceedances, the BAAQMD, in cooperation with the MTC and ABAG, prepared the Bay Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less, Than Significant Impact No Impact DECEMBER, 2010 9 INITIAL STUDY — 16005 LOs GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Area 2005 Ozone Strategy (BAOS) in September 2005 and Particulate Matter Implementation Schedule (PMIS) in November 2005. The PMIS discusses how the BAAQMD implements the California Air Resources Board's 103 particulate matter control measures. In September 2010, the BAAQMD adopted the 2010 Bay Area Clean Air Plan (CAP), which updates the BAOS. The consistency of the proposed project with the most recently adopted regional air quality plan, the CAP, is determined by comparing the project's consistency with the Los Gatos General Plan. Since the CAP is based on population projections of the Association of Bay Area Governments (ABAG) that are based on the Town's General Plan in effect at the time the CAP was approved, consistency of the project with the General Plan would indicate consistency with the CAP. While the proposed mix of uses would be allowed by the site's current General Plan designation, the level of development for the site is not defined by the General Plan or Zoning Ordinance. However, the project's projected population growth would be consistent with ABAG's 2009 population projections, and therefore, the project would be consistent with the CAP. Construction Impacts. The project's construction -related air pollutant emissions would result from demolition, surface disturbance. The recently adopted BAAQMD CEQA Guidelines (June 2010) outline screening criteria, and considers a project's construction -related impact to be less than significant if it meets the screening level size, incorporates all Basic Construction Mitigation Measures, and does not include demolition, simultaneous occurrence of more than two construction phases, simultaneous construction of more than one land use type, extensive site preparation, or extensive material transport (more than 10,000 cy import/export). Since this project includes demolition and more than one land use type could be constructed simultaneously, the project's construction -related emissions were estimated based on project -specific construction factors and results are presented in Table 1. Table 1 Construction Activity Emissions (2010) Construction Phasing Estimated Average Daily Emissions (Pounds per Day)1 ROG NOx CO SO2 PM10 PM2.5 CO2 Grading2 Construction, Paving and Coating 5.0 45.5 22.5 0.0 75.5 17.3 5,200.9 28.7 36.0 35,5 0.0 2.9 2.6 4,647.6 BAAQMD Significance Thresholds 54 54 82 54 NOTES: ROG: Reactive Organic Gases NOx: Nitrogen Oxides CO: Carbon Monoxide PMio: Inhalable Particulates PM2.5: Fine Inhalable Particulates SO2: Sulfur Dioxide CO2: Carbon Dioxide Exhaust emissions will result from on- and off -site heavy equipment. The types and numbers of equipment will vary among contractors such that such emissions cannot be quantified with certainty. The URBEMIS2007 computer model was used to calculate emissions from the following prototype construction equipment fleet: Grading —1 grader, 1 rubber -tired dozer, 1 tractor/loader/backhoe, 1 water truck, 2 bobcats Construction — 1 crane, 2 forklifts, 1 generator set, 3 welders, 2 tractors/loaders/backhoes Paving — 4 cement mixers, 1 paver, 1 paving equipment, 1 roller, 1 tractor/loader/backhoe. 2 Assumed grading duration: one month (20 days) of grading; 10,181 cubic yards (cy) of cut, 48 cy of fill, 10,133 cy off -site haul using 14 cy haul trucks SOURCE: URBEMIS 2007 Model (Model output included in Attachment 2) DECEMBER,2010 10 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD As indicated in this table, the project's estimated emissions would not exceed the BAAQMD's significance thresholds for construction -related emissions. Therefore, the project's construction emissions are considered to be less than significant with implementation of the following BAAQMD-recommended Basic Construction Mitigation Measures: 1. To limit the project's construction -related dust, criteria pollutant, and precursor emissions, the following BAAQMD-recommended Basic Construction Mitigation Measures shall be implemented: ■ All exposed surfaces (e.g., parking areas, staging areas, soil piles, graded areas, and unpaved access roads) shall be watered two times per day. • All haul trucks transporting soil, sand, or other loose material off -site shall be covered. • All visible mud or dirt track -out onto adjacent public roads shall be removed using wet power vacuum street sweepers at least once per day. The use of dry power sweeping is prohibited. ■ All vehicle speeds on unpaved roads shall be limited to 15 mph. ■ All roadways, driveways, and sidewalks to be paved shall be completed as soon as possible. Building pads shall be laid as soon as possible after grading unless seeding or soil binders are used. ■ Idling times shall be minimized either by shutting equipment off when not in use or reducing the maximum idling time to 5 minutes (as required by the California airborne toxics control measure Title 13, Section 2485 of California Code of Regulations [CCRJ). Clear signage shall be provided for construction workers at all access points. • All construction equipment shall be maintained and properly tuned in accordance with manufacturer's specifications. All equipment shall be checked by a certified mechanic and determined to be running in proper condition prior to operation. ■ A publicly visible sign with the telephone number and person to contact at the Lead Agency regarding dust complaints shall be posted at the site. This person shall respond and take corrective action within 48 hours. The Air District's phone number shall also be visible to ensure compliance with applicable regulations. Operational Impacts. Air pollutant emissions associated with operation of the project would result primarily from project -related traffic (mobile sources) with a smaller increment from the project's space heating/cooling and electricity generation (area sources). The proposed project would generate approximately 1,647 average daily trips, with 194 AM peak hour trips and 146 PM peak hour trips. When trip generation from the former auto dealership is considered, the proposed mixed -use project would result in a net increase of 955 daily trips, with 151 AM peak hour trips and 92 PM peak hour trips. In accordance with recently adopted BAAQMD CEQA Guidelines (June 2010), the project's contributions to regional air quality (within San Francisco Bay Area Air Basin) were estimated using the CARB's URBEMIS 2007 computer model. The results for the project's operational average daily and annual emissions are presented in Table 2. This table indicates that pollutant emissions associated with average daily and annual project -related mobile and area sources would not exceed the recently adopted BAAQMD thresholds of significance for operational criteria pollutants and precursors. Since the BAAQMD thresholds address the impacts of project -related source emissions on local and regional air quality, the project's contribution to the total pollution burden in the region is considered to have a less -than -significant impact on local and regional air quality. DECEMBER,2010 11 INITIAL STUDY - 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Table 2 Project Regional Emissions (2011) Project Buildout Year 2011 Total Average Daily Emissions BAAQMD Average Daily Significance Thresholds Project -Related Average Daily Area Source Emissions (Pounds per Day) ROG NOx CO SO2 PMio PM2.5 CO2 4.6 1.0 7.6 0.0 0.0 0.0 1,121.9 Project -Related Average Daily Mobile Source Emissions (Pounds per Day) 10.3 13.0 131.9 0.1 21.9 4.2 12,346.7 14.9 14.0 139.5 0.1 21.9 4.2 13,468.6 54 54 - - 82 54 Project Buildout Year Project -Related Annual Area Source Emissions (Tons per Year) 1.1 0.2 1.9 0.0 0.2 0.2 233.8 2011 Project -Related Annual Mobile Source Emissions (Tons per Year) 2.0 2.8 24.7 0.0 4.0 0.8 2,151.7 Total Annual Emissions 3.1 3.0 26.6 0.0 4.2 0.9 2,385.5 BAAQMD Annual Significance Thresholds 15 15 NOTES: ROG: Reactive Organic Gases NOx: Nitrogen Oxides CO: Carbon Monoxide PM2.5: Fine Particulates S02: Sulfur Dioxide CO2: Carbon Dioxide SOURCE: URBEMIS 2007 Model (Model output included in Attachment 2) 15 PMio: Inhalable Particulates Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 4. Biological Resources - Would the project: a) Have a substantial adverse effect, either directly or through habitat modifications, on any species identified as a candidate, sensitive, or special status species in local or regional plans, policies, or regulations, or by the California Department of Fish and Game or U.S. Fish and Wildlife Service? X b) Have a substantial adverse effect on any riparian habitat or other sensitive natural community identified in local or regional plans, policies, regulations or by the California Department of Fish and Game or U.S. Fish and Wildlife Service? X c) Have a substantial adverse effect on federally protected wetlands as defined by Section 404 of the Clean Water Act (including, but not limited to, marsh, vernal pool, coastal, etc.) through direct removal, filling, hydrological interruption, or other means? X DECEMBER, 2010 12 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No impact d) Interfere substantially with the movement of any native resident or migratory fish or wildlife species or with established native resident or migratory wildlife corridors, or impede the use of native wildlife nursery sites? X e) Conflict with any local policies or ordinances protecting biological resources, such as a tree preservation policy or ordinance? X f) Conflict with the provisions of an adopted Habitat Conservation Plan, Natural Community Conservation Plan, or other approved local, regional, or state habitat conservation plan? X The project site is developed with a parking lot and auto dealership buildings from previous commercial use of the property. Vegetation on the site consists of landscape trees, shrubs, and groundcover along the perimeter of the property, consisting primarily of street trees on Los Gatos Boulevard, Blossom Hill Road, and Placer Oaks Road. Trees along the southwestern boundary of the site serve as an effective screening element for the nearby residential properties on Blossom Hill Road. The habitat value of site vegetation is limited to urban -adapted species. Policy O.P.3.3 of the Open Space Element of the Los Gatos General Plan emphasizes preservation of public and private landscaping along Town streets. The Los Gatos Tree Protection Ordinance states that the preferred tree replacement is two or more trees of a species and size designated by the Director of the Parks and Public Works Department. Tree replacement requirements are based on canopy size, which is defined in Table 3-1 of the Ordinance, Tree Canopy — Replacement Standard. Tree canopy replacement requirements range from two to six 24-inch box size trees or two 36-inch and/or 48-inch box size trees, depending on the canopy size of the tree to be removed. A tree survey was prepared for the project by the Town's consulting arborist, Arbor Resources (AR), in November 2009 and updated in October 2010. Copies of these studies are on file with the Los Gatos Community Development Department. The AR assessment and revised project plans serve as the basis for the following evaluation of the project's potential effects on trees at the property. The AR survey identified a total of 38 trees that could be affected by the proposed project. Of these 38 trees, 37 are on the subject property and one is sufficiently close on the property adjoining the site as to be vulnerable to potential damage during development [Section 29.10.0995(B) of the Town's Municipal Code]. The 38 trees listed in the inventory include 12 that are located within the public right-of-way and are regarded as "street trees," (Trees #1 through 11, and 20). Tree #38 is situated on the neighboring western property, at the northwest property corner. Trees #23 through 33 are brush cherries (Eugenia myrtifolia) that form a row along the front, western section of the site. Their conditions vary from poor to good, but serve to provide an effective screen between the project site and the neighboring western residential property. Of the 38 trees on the site, 19 trees (#3, 5 - 8, 11, 13 - 22, and 35 - 37) would be removed as a result of project implementation. Trees #6, 7, 8, and 20 (all street trees) would be scheduled for removal due to required roadway widening of Placer Oaks Road and Blossom Hill Road. Based upon species, condition, size, and assigned suitability for preservation, the proposed removal of all but four (Trees #5, 17, 19, and DECEMBER,2010 13 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD 22) of these trees would conform to Town code. Tree #17, a coast redwood (Sequoia sempervirens), is located in the southwest corner of the property. The tree is situated within the footprint of proposed Lot 5. This redwood has a trunk diameter of 40 inches and a canopy spread of 35 feet. Its overall health is fair, possibly due to a lack of adequate water to the root zone. The AR report concludes that the tree appears sufficiently viable and its vigor could potentially be improved through regular watering, fertilization, and mulching. Without suitable irrigation, the tree's condition can be expected to decline further. With regard to Tree #5, this is a southern magnolia (Magnolia grandiflora) in good condition, located in the sidewalk strip in conflict with the proposed driveway to the commercial building on Placer Oaks Road. Trees #19 and 22 are crape myrtles (Lagerstroemia indica) in healthy and apparently stable condition. These trees would be suitable for relocation rather than removal. The AR report also provides an assessment of Tree #12, a coast redwood that is situated along western perimeter of the project site. Although planned for retention, Tree #12 would be severely impacted and subjected to premature demise and instability. This is a large redwood that has a 40-inch trunk diameter, an extremely sparse canopy, and appears beyond recovery. The proposed new parking spaces adjacent to Lot 6 would be only a few feet from its trunk and, due to overcut to form and pour the curb and gutter, root loss or trunk damage at its base would be expected. When considering this tree's poor and irreversible condition, redesign to avoid this impact does not seem warranted and it should be removed. If efforts were made to retain this tree, the AR report recommends that the three parking spaces planned for this area should be omitted from the design to achieve a minimum setback of 20 feet from its trunk for any ground disturbance. The Town will require implementation of the following measure to reduce impacts on trees to be retained, and adequately replace trees to be removed: 2. With review and approval by the Town, all recommendations made by Arbor Resources (October 11, 2010 and any updates) will be implemented to eliminate or minimize the construction -related impacts on the trees to be retained. Recommendations are listed under Section 5.0, Recommendations, of the arborist's report. These include recommendations under the Design Guidelines section addressing tree retention and relocation, soil disturbance, mulching, trenching, drainage facilities, and installation of new trees. The report also provides recommendations for Protection Measures before and during construction, encompassing fencing, removal of hardscape, demolition, work within tree canopies, etc. The report's recommendations are included as Attachment 3. Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 5. Cultural Resources - Would the project: a) Cause a substantial adverse change in the significance of a historical resource as defined in 15064.5? X b) Cause a substantial adverse change in the significance of an archaeological resource pursuant to 15064.5? X c) Directly or indirectly destroy a unique paleontological resource or site or unique geologic feature? X d) Disturb any human remains, including those interred outside of formal cemeteries? X DECEMBER, 2010 14 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Project implementation would result in demolition of existing buildings on the site. No significant impacts on historic resources would result from the proposed demolition. An archaeological literature review was undertaken by Holman & Associates at the Northwest Information Center (NWIC) located at Sonoma State University (file no. 09-1292) to obtain information about recorded historic and prehistoric archaeological sites in and around the project area, and information about previous archaeological field studies of the project area and its surroundings. A copy of the Holman report is on file and available for public review at the Los Gatos Community Development Department. The review of NWIC records indicates that there has been no previous archaeological field inspection of the project area, and that there are no recorded historic or prehistoric sites inside the project borders, or within 1,000 feet of the project site. The NWIC inventory maps indicate a possible archaeological site (otherwise not described) located along Blossom Hill Road west of the project area. Holman & Associates conducted a visual inspection of the project site as part of their evaluation of the project site for the presence of potential archaeological resources. No evidence of historical or archaeological resources was discovered during either the field inspection or the literature review. Holman concluded that the project site has a low potential for containing buried cultural resources, and therefore, mechanical subsurface presence/absence testing is not warranted, nor is it recommended that an archaeologist be present during construction -related earthmoving activities. However, since over 90% of the ground surface on the project site is covered either by buildings, pavement, and/or landscaping, the potential for discovery of obscured cultural resources during future development of the project site would still remain. Given the site's proximity to the historic alignment of Los Gatos Creek and proposed grading for residential and commercial construction, the potential for encountering cultural resources cannot be completely eliminated. Therefore, the following mitigation measures will be required: 3. Construction personnel involved with earthmoving shall be alerted to the potential for the discovery of prehistoric materials and in particular, concentrations of historic artifacts. Prehistoric archaeological resources could include but not be limited to the following: darker than surrounding soils of a friable nature, concentrations of stone, bone or fresh water shellfish, artifacts of these materials, and evidence of fire (ash, charcoal, fire altered earth or rock) and of course, burials, both human and animal. 4. In the event that archaeological traces are encountered, all construction within a 20-foot radius of the find shall be halted, the Community Development Director shall be notified, and an archaeologist shall be retained to examine the find and make appropriate recommendations. 5. In the event that it appears further earthmoving will affect a resource eligible for the California Register of Historic Resource (CRHR), a plan for evaluation of the resource through limited hand excavation should be submitted to the Town's Community Development Department for approval. If evaluative testing demonstrates that the project will affect a CRHR eligible resource, a plan for the mitigation of impacts to the resource should be submitted to the Community Development Department for approval before construction is allowed inside the zone designated as archaeologically sensitive. 6. If the Community Development Director finds that the archaeological find is not a significant resource, work will resume only after the submittal of a preliminary archaeological report and after provisions for reburial and ongoing monitoring are accepted. Provisions for identifying descendants of a deceased Native American and for reburial will follow the protocol set forth in CEQA Guidelines DECEMBER,2010 15 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Section 15064.5(e). If the site is found to be a significant archaeological site, a mitigation program will be prepared and submitted to the Community Development Director for consideration and approval, in conformance with the protocol set forth in Public Resources Code Section 21083.2. 7. A final report shall be prepared when a find is determined to be a significant archaeological site, andior when Native American remains are found on the site. The final report will include background information on the completed work, a description and list of identified resources, the disposition and curation of these resources, any testing, other recovered information, and conclusions. Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 6. Geology and Soils - Would the project expose people or structures to potential substantial adverse effects, including the risk of loss, injury, or death involving: a) Rupture of a known earthquake fault, as delineated on the most recent Alquist-Priolo Earthquake Fault Zoning Map issued by the State Geologist for the area or based on other substantial evidence of a known fault? Refer to Division of Mines and Geology Special Publication 42. X b) Strong seismic ground shaking? X c) Seismic -related ground failure, including liquefaction? X d) Landslides? X e) Result in substantial soil erosion or the loss of topsoil? X f) Be located on a geologic unit or soil that is unstable, or that would become unstable as a result of the project, and potentially result in on- or off -site landslide, lateral spreading, subsidence, liquefaction or collapse? X g) Be located on expansive soil, as defined in Table 18-1-B of the Uniform Building Code (1994), creating substantial risks to life or property? X h) Have soils incapable of adequately supporting the use of septic tanks or alternative wastewater disposal systems where sewers are not available for the disposal of waste water? X A review of the Town's hazards maps4 indicates that the project site has a moderate shrink -swell potential, very low potential for liquefaction, moderate potential for fault rupture, and moderate potential for seismic shaking. Due to the site's relatively level topography, no erosion, slope stability, or debris " Nolan Associates, 1999. Draft Erosion Potential Map, Shrink -Swell Potential of Soils, Slope Stability Hazard. Map, Debris Flow Hazard Map, Liquefaction Hazard Zones Map, Seismic Shaking Hazards Map, Geologic Map, Fault Rupture Hazard Zones Map for the Town of Los Gatos General Plan Update, March 20, DECEMBER,2010 16 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD flow hazards were identified for the site. The Town's Fault Map indicates that there is a concealed fault trace that may traverse the northeast corner of the site. Cornerstone Earth Group (CEG) conducted a geotechnical-investigation of the project site and presented the results of the analysis in a report dated October 21, 2009. The CEG geotechnical investigation consisted of field and laboratory programs to evaluate physical and engineering properties of the subsurface soils (including borings), review of aerial photos, and engineering analysis. The Town retained AMEC Geomatrix Consultants, Inc. (Geomatrix), a geotechnical consulting firm, to review the CEG study. The Geomatrix assessment (dated December 3, 2009) concluded that the CEG geotechnical study characterized the project site and generally made appropriate recommendations for the project. Geomatrix identified three residual concerns that required further evaluation by CEG. These concerns addressed the geologic and seismic conditions, and geotechnical engineering considerations as these relate to the proposed project. On December 18, 2009, CEG provided additional information and clarification on its analyses in a response to the Geomatrix review. In a March 23rd 2010 letter, Geomatrix provided additional observations concerning CEG responses and concurred with CEG that the proposed project is feasible, provided CEG's geotechnical engineering recommendations are incorporated into the project design. Copies of all reports are on file at the Los Gatos Community Development Department.5 The property is located east of Los Gatos Creek, on an alluvial plain that is rimmed on the west, south and east by the foothills of the Santa Cruz Mountains. The subject property is underlain, at depth, by sedimentary bedrock materials of the Tertiary -age Monterey Shale and Temblor Sandstone formations. However, bedrock units were not observed in the site vicinity due to concealment by overlying valley floor sediments: According to CEG, regional geologic maps indicate that the overlying sediments are Pleistocene -age alluvial fan deposits. The depth to Tertiary bedrock below the property is not known, but is assumed to be on the order of 100 feet or more. Geotechnical borings previously drilled on the site in 2006 encountered imported fill and the native alluvial materials consisting of clayey sands and clayey sands with gravels, cobbles, and boulders. A small area of artificial fill encountered near the center of the property is associated with an excavation and loose backfill by the previous property owner. CEG indicated that the project site is not located in a currently designated Alquist-Priolo Earthquake Fault Zone. However, the property is situated within the Santa Clara County Fault Hazard Zone, which is based on mapping of the Shannon fault zone. A concealed, possible fault trace that is projected more than a mile from a fault observed in the Blossom Hill area is depicted as crossing the northeastern corner of the property. The property is located in a "moderate" fault rupture potential zone, according to the Town of Los Gatos fault rupture hazard zone categories. The "moderate" category includes properties that meet one of the following criteria: 1) areas located within 400 to 500 feet of the dotted, concealed fault traces; 2) areas containing concentrated clusters of mapped aerial photo lineaments; or 3) areas with widespread evidence of coseismic deformation caused by the 1989 Loma Prieta earthquake. The property is not located within an area of mapped aerial photo lineaments or coseismic deformation caused by the 1989 Loma Prieta Cornerstone Earth Group, Updated Geotechnical Investigation, Mixed -Use Development, 16005 Los Gatos Boulevard, Los Gatos, California. October 21, 2009. Cornerstone Earth Group, Response to Peer Review Comments, Mixed -Use Development, 16005 Los Gatos Boulevard, Los Gatos, California. December 18, 2009. AMEC Geomatrix, Inc. Peer Review — Geotechnical Investigations and Plans, Mixed Use Development, 16005 Los Gatos Boulevard, Los Gatos, California. December 3, 2009. AMEC Geomatrix, Inc. Supplemental Peer Review — Geotechnical Investigations and Plans, Mixed Use Development, 16005 Los Gatos Boulevard, Los Gatos, California. March 23, 2010. DECEMBER,2010 17 INITIAL STUDY — 16005 LOs GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD earthquake. However, fault mapping for the project area indicates that the property is located within 400 to 500 feet of a concealed fault trace. According to CEG, the Geotechnical and Seismic Safety Element Working Paper for the Town of Los Gatos6 recommends that fault hazard studies (i.e. geologic investigations that include trenching) be prepared for structures situated in the "high" ground rupture potential category, but not for structures in the "moderate" category. Based on review of available information as well as site -specific data, CEG concluded that the potential for fault rupture hazards at the site during the lifetime of the project is considered to be low. CEG also determined that the potential for liquefaction, lateral spreading, or seismic settlement to occur at the site is low. However, CEG indicated that the proposed project, similar to other development in the Bay Area, would be subject to strong ground shaking in the event of a moderate to severe earthquake. The primary geotechnical concern identified by CEG is differential settlement that could occur in engineered fill when in proximity to dense native soils. The review by Geomatrix recommended further evaluation of the potential for this hazard to occur with project development. CEG has indicated that the slight increase in potential differential settlement could be accommodated in the structural design of the building foundations. The following measure shall be required to reduce potential geotechnical hazards to a less -than - significant level: 8. The recommendations of the CEG geotechnical investigation and project review (October 21, 2009 and December 18, 2009) shall be incorporated in the final construction plans for the proposed project (Attachment 4). These recommendations address site preparation, earthwork operations, drainage, and foundations. Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 7. Greenhouse Gases - Would the project: a) Generate greenhouse gas emissions, either directly or indirectly, that may have a significant impact on the environment, based on any applicable threshold of significance? X b) Conflict with any applicable plan, policy or regulation of an agency adopted for the purpose of reducing the emissions of greenhouse gases? X "Greenhouse gases" (so called because of their role in trapping heat near the surface of the earth) emitted by human activity are implicated in global climate change, commonly referred to as "global warming." These greenhouse gases contribute to an increase in the temperature of the earth's atmosphere by transparency to short wavelength visible sunlight, but near opacity to outgoing terrestrial long wavelength heat radiation. The principal greenhouse gases (GHGs) are carbon dioxide, methane, nitrous oxide, ozone, and water vapor. Fossil fuel consumption in the transportation sector (on -road motor vehicles, off - highway mobile sources, and aircraft) is the single largest source of GHG emissions, accounting for 6 Nolan Associates, 1999. Geotechnical and Seismic Safety Element Working Paper, Los Gatos General Plan Update: report to William. Frost & Associates. January 30, 1999. DECEMBER,2010 18 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD approximately half of GHG emissions globally. Industrial and commercial sources are the second largest contributors of GHG emissions with about one-fourth of total emissions. California has passed several bills and the Governor has signed at least three executive orders regarding greenhouse gases. The Governor's Office of Planning and Research is in the process of developing CEQA significance thresholds for GHG emissions but thresholds have yet to be established. GHG statutes and executive orders (BO) include AB 32, SB 1368, EO S-03-05, EO S-20-06 and EO S-01-07. AB 32 is one of the most significant pieces of environmental legislation that California has adopted. Among other things, it is designed to maintain California's reputation as a "national and international leader on energy conservation and environmental stewardship." It will have wide-ranging effects on California businesses and lifestyles as well as far reaching effects on other states and countries. A unique aspect of AB 32, beyond its broad and wide-ranging mandatory provisions and dramatic GHG reductions are the short time frames within which it must be implemented. Major components of the AB 32 include: • Require the monitoring and reporting of GHG emissions beginning with sources or categories of sources that contribute the most to statewide emissions. • Requires immediate "early action" control programs on the most readily controlled GHG sources. • Mandates that by 2020, California's GHG emissions be reduced to 1990 levels. • Forces an overall reduction of GHG gases in California by 25 to 40%, from business as usual, over the next 13 years (by 2020). • Must complement efforts to achieve and maintain federal and state ambient air quality standards and to reduce toxic air contaminants. Statewide, the framework for developing the implementing regulations for AB 32 is under way. Additionally, through the California Climate Action Registry (CCAR, now called the Climate Action Reserve), general and industry -specific protocols for assessing and reporting GHG emissions have been developed. GHG sources are categorized into direct sources (i.e. company owned) and indirect sources (i.e. not company owned). Direct sources include combustion emissions from on -and off -road mobile sources, and fugitive emissions. Indirect sources include off -site electricity generation and non -company owned mobile sources. Project -Related Greenhouse Gas Emissions. Implementation of the proposed project would contribute to long-term increases in greenhouse gases (GHGs) as a result of traffic increases (mobile sources) and minor secondary fuel combustion emissions from space heating, etc. Development occurring as a result of the proposed project would also result in other secondary operational increases in GHG emissions as a result of electricity generation to meet project -related increases in energy demand. Electricity generation in California is mainly from natural gas -fired power plants. However, since California imports about 20 to 25% of its total electricity (mainly from the northwestern and southwestern states), GHG emissions associated with electricity generation could also occur outside of California. Space or water heating, water delivery, wastewater processing and solid waste disposal also generate GHG emissions. Short-term GHG emissions would also be generated by project -related construction activities. The General Reporting Protocol (GRP) in the California Climate Action Registry (CCAR) divides project -related operational GHG emissions into three categories. These three sources include the following: Source 1: On -site combustion of fossil fuels (space and water heating, fireplaces, landscape utility equipment, etc.) Source 2: Consumption of purchased energy (electricity) DECEMBER,2010 19 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Source 3: Indirect emissions (transportation, solid waste disposal, fresh -and wastewater conveyance and treatment) For general development projects such as the proposed project, Source 3 is typically a much larger contributor to the GHG burden than Sources 1 and 2. For purposes of analysis, project -related GHG emissions were aggregated into transportation and non -transportation sources. The transportation component is calculated and reported in the URBEMIS2007 computer model. The non -transportation sources require separate analysis, and both calculation methods are included in Attachment 2. Construction Impacts. Project construction would generate exhaust emissions from off -road equiptent, on -road trucking, and construction worker commuting traffic during this period, but these emissions are expected to contribute minimally to long-term regional increases in GHGs. No state agency or the BAAQMD has adopted a methodology or quantitative threshold that can be applied to a specific development project to evaluate the significance of an individual project's construction -related contribution to GHG emissions, such as those that exist for criteria pollutants. However, the recently adopted BAAQMD CEQA Guidelines recommend that a project's construction -related GHG emissions be quantified and a significance determination be made in relation to meeting AB 32 GHG reduction goals. Pursuant to the BAAQMD Guidelines, the URBEMIS2007 computer model was used to estimate the project's construction -related GHG emissions. Project -related construction activities are estimated to generate a maximum of approximately 89 short tons (91 metric tons, MT) in 2010 and 523 short tons (475 MT) in 2011 of CO2 (see URBEMIS Model output in Attachment 2). Since equipment exhaust also contains small amounts of methane and nitric oxides, also GHGs, the project's total CO2-equivalent (CO2e) emissions (all GHGs) would be approximately 91 MT in 2010 and 475 MT in 2011.7 While there is no adopted or proposed significance threshold for construction -related emissions, the construction - related GHG emissions would be well below the proposed BAAQMD significance threshold for long- term operational emissions of 1,100 MT of CO2e per year. Therefore, the project's construction -related GHG impacts would not conflict with the state's goals of reducing GHG emissions to 1990 levels by 2020, and is considered less than significant. Implementation of Mitigation Measure #1, which limits idling of construction equipment (as required by Title 13 of the California Code of Regulations, Section 2485), would also further reduce the project's construction -related GHG emissions. Operational Impacts. Implementation of the proposed project would contribute to long-term increases in greenhouse gases (GHGs) as a result of traffic increases (direct emissions from mobile sources) and minor secondary fuel combustion emissions from electrical consumption, space heating, etc. (indirect emissions from non -mobile sources). Estimated annual GHG emissions, from project -related direct and indirect would be as follows: ■ Total Non -Transportation • Total Transportation • Combined CO2e 449 tons/year 2,152 tons/year 2,601 tons/year or 2,365 MT/year The recently adopted BAAQMD CEQA Guidelines include the following significance thresholds for GHG: annual GHG emissions of 1,100 MT or 4.6 MT/service population (residents and employees). The project's annual emissions would exceed the 1,100 MT annual threshold and would also exceed the 4.6 MT per person threshold (2601 MT per 131 residents and 38 employees). Therefore, the project's When CO, and non -CO, GHG emissions are considered together, they are referenced as CO2-Equivalents (CO2-E), which add approximately three percent to CO, emissions from diesel equipment exhaust. DECEMBER,2010 20 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD operational GHG emissions are considered potentially significant. Therefore, it is recommended that energy efficiency measures be incorporated into the proposed building to the maximum extent feasible until such time that a methodology is adopted and mitigation can be applied. While the proposed building will be required to comply with energy efficiency requirements of the California Energy Code (Title 24, Part 6 of the California Administrative Code), the Town will also require completion of the LEED checklist for commercial portion of the project and GreenPoint checklist for single-family residential portion (pursuant to the Town's adoption of near -term policy recommendations from the Santa Clara County Cities Association Green Building Collaborative in April 2008). The Town has not adopted rating standards for private development, but adopted the LEED Silver standard for all new public construction and renovation projects over 5,000 s.f. The project applicant completed the LEED and GreenPoint checklists and based on proposed energy efficiency features, the project would meet the LEED Platinum standard, LEED's highest standard. The project is estimated to achieve a GreenPoint rating score of 148, which exceeds the minimum GreenPoint rating score of 50 points. The GreenPoint checklist considers project design elements, but also considers recycling of construction waste, community planning (i.e. infill), and material source locations (within 500 miles). Pre -certification LEED and GreenPoint estimates are included as Attachment 5. Implementation of LEED and GreenPoint standards is considered to reduce the project's impact to a less -than -significant level since this would be consistent with the Town's adopted GHG policies. For the proposed project, the transportation component would comprise approximately 83% of the project -related GHG emissions. Reductions in the vehicular contribution are therefore critical in achieving adopted state and local goals for reducing GHG emissions. However, except for encouraging infill development, achieving substantial mobile sources emissions reductions by reducing vehicular trips or trip lengths and increasing vehicle fuel efficiency are not achievable on a project -specific basis. State and national programs are in place to significantly upgrade fuel efficiencies. The proposed mix of uses, internal pedestrian connections proposed (paseos), centralized project location (infill development) would help to capture or share trips, encourage pedestrian access to nearby commercial amenities. The project's location on a bus route would also encourage use of transit, particularly with the provision of senior housing at this location. GHG reduction measures that can be implemented on a project -level basis are similar to measures that also reduce criteria air pollutants. In general, measures that reduce trip generation or trip lengths, optimize the transportation efficiency of a region, and promote energy conservation within a development will reduce GHG emissions. Additionally, carbon sequestering can be achieved through urban forestry measures. Project -specific design measures that could be implemented to reduce the project's contribution to the cumulative GHG impacts include the following: Land Use and Transportation • Promote increased utilization of public transit • Provide continued support for rideshare programs to encourage the use of alternatives to the single occupant vehicle (SOV) for site access and trips originating at the site Energy Conservation • Construct the new residential building to exceed California Title 24 energy efficiency requirements by ten (10) percent. • Construct the new commercial buildings to meet LEED (Leadership in Energy and Environmental Design) Silver Certification DECEMBER,2010 21 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD • Maximize use of low pressure sodium and/or fluorescent lighting Require acquisition of new appliances and equipment to meet Energy Star certification Urban Forestry Participate in green waste collection and recycling programs for landscape maintenance Encourage use of landscaping with low water requirements and fast growth. • Plant trees or vegetation to shade buildings and thus reduce heating/ cooling demand As indicated in the LEED and GreenPoint checklists completed for the project, three of the above measures have been incorporated into the project design. The project site is located adjacent to a bus stop, the commercial component of the project would exceed the LEED Silver standard, Energy Star appliances are proposed to be installed, landscaping is proposed to be have low water requirements, and shade trees would be planted. Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 8. Hazards and Hazardous Materials - Would the project: a) Create a significant hazard to the public or the environment through the routine transport, use, or disposal of hazardous materials? X b) Create a significant hazard to the public or the environment through reasonably foreseeable upset and accident conditions involving the release of hazardous materials into the environment? X c) Emit hazardous emissions or handle hazardous or acutely hazardous materials, substances, or waste within one - quarter mile of an existing or proposed school? X d) Be located on a site which is included on a list of hazardous materials sites compiled pursuant to Government Code Section 65962.5 and, as a result, would it create a significant hazard to the public or the environment? X e) For a project located within an airport land use plan or, where such a plan has not been adopted, within two miles of a public airport or public use airport, would the project result in a safety hazard for people residing or working in the project area? X f) For a project within the vicinity of a private airstrip, would the project result in a safety hazard for people residing or working in the project area? X g) Impair implementation of or physically interfere with an adopted emergency response plan or emergency evacuation plan? X DECEMBER, 2010 22 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact h) Expose people or structures to a significant risk of loss, injury or death involving wildland fires, including where wildlands are adjacent to urbanized areas or where residences are intermixed with wildlands? X A Phase I Environmental Site Assessment (ESA) was conducted for the project site by EFI Global in February 2006.8 The ESA is on file with the Los Gatos Community Development Department. The project site was used for agricultural purposes (fruit orchard) from at least 1939 until 1959. By 1959, the eastern and northern portions of the site were developed by Mr. Paul Swanson as a car sales and service dealership. The auto dealership consisted of two buildings and a covered auto detail area: • The first building, located in the eastern portion of the project site, was used as an auto showroom, offices, parts department, and service area. • The second building, located in the center of the site, had office and lunch areas, a car wash, and service bays. • The covered detail structure and outdoor service area, located between these two buildings, has one three -stage clarifier on the northeast side of the detail area, a second clarifier located west of the third building, 25 underground hydraulic lifts located in service areas of the facility, and five aboveground hydraulic lifts in an outdoor service area located between the first and second buildings. The residence remained in use on the southwestern portion of the site until sometime between 1965 and 1971. The residence was then removed and the dealership expanded into that area with the construction of a building, which was initially used for the sales and service of recreational vehicles (RVs). This building has offices, a spray booth and service area. In 1991, two underground storage tanks (UST) were removed from the project site. Subsurface investigations and remediation were conducted subsequent to their removal in 1991. Based on the results of the investigation, the Santa Clara County Valley Water District provided a Case Closure letter for the project site regarding these USTs on December 29, 1995. In 1993, five additional USTs were removed. Petroleum hydrocarbon constituents were detected below the waste oil piping. Additional sampling conducted in the piping area did not reveal the presence of petroleum hydrocarbons, and a 1997 letter from the Santa Clara County Fire Department indicates that the UST closures were considered complete by that agency. According to the regulatory agency database report obtained by EFI, several off -site facilities have reported that the subsurface below those off -site facilities is impacted with petroleum hydrocarbons and chlorinated solvents. However, based on review of Santa Clara County Department of Environmental Heath (SCCDEH) Leaking Underground Storage (LUST) case files and Santa Clara County Valley Water District (SCCVWD) Solvent Case file, these facilities do not appear to be a potential environmental " EFI Global, Phase 1 Environmental Site Assessment, Swanson Ford, 16005 Los Gatos Boulevard & 625 Blossom Hill Road, February I, 2006. DECEMBER,2010 23 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD concern to the project site at this time based on distance and direction from the site with respect to groundwater flow direction and gradient. Based upon reconnaissance of the project site and adjacent properties, review of regulatory agency lists and files, review of historical documents and interviews with knowledgeable persons, the EFI assessment reveals the following evidence of recognized environmental conditions (RECs) in connection with the site: • One groundwater monitoring well was installed at the project site as part of a LUST investigation, conducted in 1991. The investigation was completed, and the project site received Case Closure in 1995. It appears that this well has not been used since 1991, and should have been properly abandoned prior to granting of the closure status of the site, and was probably inadvertently missed. EFI recommends that this groundwater monitoring well should be properly destroyed under permit to the proper regulating agency. • While the facilities on the project site appeared in good condition overall, some spillage has been noted in the past by SCCDEH and SCCFD hazardous materials inspectors. In addition, some staining and spillage was noted at the time of the site visit. While spills were reportedly cleaned with absorbent material and concrete flooring in service areas generally appears to be in good condition, it is possible that some impact on the subsurface soils has occurred during the time the project site was used as a dealership and repair facility. • There are 26 underground and hydraulic lifts, and most of these have a subsurface oil reservoir enclosed in the piston of each lift. There was also one other underground lift in the car wash area adjacent to the body shop (formerly located in the second building) that was reportedly abandoned and removed, but no soil sampling was done at the time of the removal. EFI recommends that removal of these lifts be observed and soil samples collected as part of the removal process. • There are two clarifiers (exterior oil/water separators) on the project site. EFI recommends that the clarifiers be removed and that the condition of the soil below these features be assessed. • A stormwater sump is located on the southeast side of the second building and it is used to collect stormwater, then direct it northward toward storm drains located along the northern site boundary. The proximity of this sump in proximity to the hazardous materials storage and service areas of the facility poses an environmental concern. EFI recommends that the soils below this feature be assessed to evaluate subsurface soil conditions in the vicinity of this feature. • Hazardous materials have been stored on the site and a Hazardous Materials Management Plan/ Hazardous Materials Business Plan (HMMP/HMBP) is maintained with the SCCFD. A facility closure notice documenting compliance with the Santa Clara County Fire Department (SCCFD) requirements should be obtained. Based on EFI's experience with other facility closures within Santa Clara County, it is likely that the facility closure would involve the removal of the hoists, sumps, clarifier, hazardous materials and debris. Any confirmation soil sampling and subsurface closure activities would be overseen by the Santa Clara County Department of Environmental Health (SCCDEH). During this assessment of the subject property, EFI has identified the following potential environmental issue, which is not considered a REC: • A limited visual asbestos -containing materials (ACMs) survey was conducted at the site. The facility was constructed in 1959 when ACMs were still commonly used in building materials. In addition, DECEMBER,2010 24 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD limited testing of potential ACM conducted in 1996 revealed the presence of ACM in heating duct insulation and wrap in the first building. Potential ACM observed during the site inspection included wallboard and joint compounds, roofing materials, and vinyl floor tiles and sheeting. Although no inspection for lead -based paints was conducted by EFI, it is possible that lead -based paints could also be present in existing structures. Proposed demolition of these structures could result in airborne release of hazardous building materials, such as asbestos fibers or Lead dust. If found to be present in building materials to be removed, asbestos and/or lead abatement practices such as containment and removal will be required prior to demolition. The project applicant will be required to obtain clearance for asbestos removal from the Bay Area Air Quality Management District prior to issuance of a demolition permit. Therefore, compliance with this requirement will reduce to less than significant the potential for public health hazards associated with the release of airborne asbestos fibers at the project site. Due to the extent of grading required, proposed demolition of existing facilities and proposed removal of underground facilities, the following measures will be required to reduce potential hazardous materials impacts to a less -than -significant level: 9, The project applicant and/or Town shall prepare a management plan to identify all suspected hazardous materials and specify applicable regulations that would determine appropriate handling and disposal of these materials. For suspected hazardous materials (contaminated soil and groundwater) that may be encountered during construction, the management plan shall include contingency plans for site safety, worker protection, sampling and investigation, and disposal or remediation; these shall be based on soil and groundwater sampling and testing that have been completed to date. The management plan shall be filed with the Town of Los Gatos and all other jurisdictional agencies prior to issuance of the demolition and grading permits. 10. If groundwater is encountered during project construction and dewatering is required, the project applicant shall undertake sampling and testing of the encountered groundwater in accordance with the contingency sampling and investigation plan. If groundwater is found to contain contaminants that exceed regulatory action levels, it may not be discharged into the existing storm drainage system. Removal and handling of the contaminated groundwater should be done in a manner acceptable to the RWQCB, the Town, and other jurisdictional agencies. 11. A state certified lead -based paint professional shall be retained to perform a lead -based paint survey of the existing structures and the recommendations of the professional shall be followed for abatement of any identified lead -based paint prior to demolition of the structures. Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 9. Hydrology and Water Quality - Would the project: a) Violate any water quality standards or waste discharge requirements? X DECEMBER, 2010 25 INITIAL STUDY - 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant ' Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact X b) Substantially deplete groundwater supplies or interfere substantially with groundwater recharge such that there would be a net deficit in aquifer volume or a lowering of the local groundwater table level (e.g., the production rate of pre-existing nearby wells would drop to a level which would not support existing land uses or planned uses for which permits have been granted)? c) Substantially alter the existing drainage pattern of the site or area, including through the alteration of the course of a stream or river, in a manner which would result in substantial erosion or siltation on- or off -site? X d) Substantially alter the existing drainage pattern of the site or area, including through the alteration of the course of a stream or river, or substantially increase the rate or amount of surface runoff in a manner, which would result in flooding on- or off -site? X e) Create or contribute runoff water which would exceed the capacity of existing or planned stormwater drainage systems or provide substantial additional sources of polluted runoff? X f) Otherwise substantially degrade water quality? X g) Place housing within a 100-year flood hazard area as mapped on a federal Flood Hazard Boundary or Flood Insurance Rate Map or other flood hazard delineation map? X h) Place within a 100-year flood hazard area structures, which would impede or redirect flood flows? X i) Expose people or structures to a significant risk of loss, injury or death involving flooding, including flooding as a result of the failure of a levee or dam? •X j) Inundation by seiche, tsunami, or mudflow? X Storm Drainage. Approximately 95 percent (or 186,363 s.f.) of the 4.4-acre project parcel is covered with the impervious surfaces of the site's building, concrete slab foundation and asphalt parking lot. Project development would result in approximately 75 percent (147,909 s.f.) of the site being covered by driveways, parking, sidewalks, or building. This would result in approximately 20 percent net decrease in impervious surfaces on the project site and potential reduction in peak surface flows from the project site, a beneficial impact of the proposed project. Presently, storm runoff flows on the project site discharge to storm drains on the site, which connect to two 18-inch storm drains in Los Gatos Boulevard. Since the project would result in a net reduction in impervious surfaces, the project would not adversely affect the capacity of existing storm drains. DECEMBER, 2010 26 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Flood Hazards. According to the Federal Emergency Management Agency's (FEMA) Flood Insurance Rate Map (FIRM) (May 18, 2009) for Los Gatos, the project site is located in Zone X, consisting of areas with 0.2% annual chance of flood, areas of one percent annual chance flood with average depths of less than one foot or with drainage areas less than one square mile, and areas protected by levees from one percent chance flood. The Hydrology and Water Quality Map in the Background Report for the General Plan Update also indicates that the project site is located outside mapped 100-year flood hazard areas. Water Quality. Stringent water quality regulations of the Clean Water Act have recently been triggered because the NPDES (National Pollution Discharge Elimination System) permit program has failed to protect beneficial uses of Santa Clara County's creeks and the South San Francisco Bay, as evidenced by such observations as violations of ambient water quality criteria, high concentrations of toxic substances, and fish consumption health advisories. These regulations require that all discharges shall comply with Provision C.3, New And Redevelopment Performance Standards of Order No. 01-024 of the NPDES permit program. The project site is located within the Los Gatos Creek watershed and runoff from the site ultimately discharges into Los Gatos Creek (west of the site) and eventually into the Bay. Los Gatos Creek is on the Clean Water Act Section 303(d) List of Water Quality Limited Segments due to the presence of diazinon, a pesticide, and its primary source is identified as urban runoff and storm drains. Best Management Practices (BMPs) outlined by the Santa Clara Valley Urban Runoff Pollution Prevention Program (SCVURPPP) for treatment control of pesticides are bioretention, infiltration, and media filter with adsorption/absorption as the removal process. After project completion, surface runoff from the site would be expected to carry typical urban pollutants generated by parking lots, building surfaces, and landscape areas. As a condition of project approval, the Town will require preparation and implementation of interim and final erosion control plans as well as non -point source pollution prevention measures such as installation of filtration devices or use of bio- swales. Implementation of such measures would reduce potential water quality impacts to a less -than - significant level. Project plans include a preliminary grading plan and a stormwater management plan that identify existing and proposed drainage facilities for the site. The proposed drainage plan delineates runoff source control measures and Best Management Practices (BMPs) to be used in the control of runoff originating on the project site. The proposed treatment measures for this project are three proprietary, manufactured bioretention units, and two bioswales. The three units would be located in the area of the residential lots and would treat street, driveway, walkway, and building runoff. The roof downspouts from the single-family homes would drain to landscaping and excess runoff would flow to the street.. The two bioswales, shown in four segments on project plans, would be located on the eastern edge of the site along Los Gatos Boulevard and would drain the remainder of the retail area and entrance road. The proposed project involves removal and replacement of more than 10,000 s.f. of impervious surfaces and thus must satisfy C.3 numerical requirements for treatment. The C.3 requirements also specify that a trash enclosure area is to be covered and connected to the sanitary sewer system. Since the area of disturbance would involve more than one acre, a Storm Water Pollution Prevention Plan (SWPPP) would be required by the Town. The State General Permit requires the applicant to file a Notice of Intent (NOI) to obtain coverage, and to prepare a Stormwater Pollution Prevention Plan (SWPPP) for the construction phase of the project. The Town is responsible for ensuring that the applicant has filed the NOI and that the SWPPP is consistent with local ordinances. With the required SWPPP, the project's potential impact on water quality would be less than significant. Final detailed plans and calculations will be submitted to the Town for final review and approval. DECEMBER,2010 27 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD In order to determine the adequacy of the water quality control measures proposed by the project, the Town has retained an engineering consultant, Eisenberg, Olivieri & Associates (EOA),9 to review submitted project plans for compliance with the stormwater requirements in the Town's NPDES Permit. The EOA reviews of the project (included as Attachment 6) indicate that the total amount of impervious surface created and/or replaced at this site is 147,909 square feet (3.4 acres). Since this is greater than the C.3 threshold of 10,000 square feet, the C.3 treatment requirements would apply to this project. During the review process the project plans were revised to address recommendations provided by EOA's Memorandum dated May 22, 2010. EOA's subsequent review dated November 15, 2010 of the revised plans indicates that the project's proposed stormwater treatment facilities have incorporated some of the EOA recommendations (e.g. reduction of mechanical treatment and use of bioswale treatment of all commercial area runoff). The applicant has also committed to the use of additional landscape areas for stormwater filtration pending the results of a soils investigation to determine percolation characteristics of site soils. Although no design details for the bioswales are included in the proposed stormwater treatment plans, the EOA review indicates that the area reserved for the bioswales ranges from about 5 to 20% of the contributing area and concludes that this area would be sufficient for adequate treatment. The engineering review of the project indicates that the stormwater treatment measures specified for this project meet the Town's NPDES Permit Provision C.3 requirements, and therefore, the project's water quality impact would be less than significant. The project site is located in a "red" area of the Santa Clara Valley Urban Runoff Pollution Prevention Program (SCVURPPP) Hydromodification Management Plan (HMP) Applicability Map, which means that the site is exempt from hydromodification requirements. Also, projects that do not create an increase in impervious surface over pre -project conditions are exempt. Since the proposed project would reduce the amount of impervious surface on subject property, the project is not required to implement hydromodification control measures. The preliminary erosion control measures shown on the project plans (Sheet C-8.0) are consistent with the Town's ordinances addressing stormwater pollution control and erosion and sediment control requirements. issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 10. Land Use and Planning - Would the project: a) Physically divide an established community? X b) Conflict with any applicable land use plan, policy, or regulation of an agency with jurisdiction over the project (including, but not limited to the general plan, specific plan, local coastal program, or zoning ordinance) adopted for the purpose of avoiding or mitigating an environmental effect? X c) Conflict with any applicable habitat conservation plan or natural community conservation plan? X 9 Memoranda Dated May 22, 2010 and November 15, 2010 from Jill Bicknell, P.E„ Eisenberg, Olivieri & Associates to John Gaylord, Town of Los Gatos, Regarding 16005 Los Gatos Blvd. Mixed Use Project - Conceptual Plan Review of Project Submittals for Compliance with Stormwater Requirements. DECEMBER, 2010 28 INITIAL STUDY - 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD The site is currently developed with facilities related to the former auto dealership use, paved parking Lots, and landscaping. The project parcel is currently designated by the existing General Plan as "Mixed Use Commercial," while the site is zoned "CH, Restricted Highway Commercial." The Mixed Use Commercial General Plan designation allows for "a mixture of retail, office, residential in a mixed use setting, along with lodging, service, auto -related businesses, non -manufacturing industrial uses, recreational uses and restaurants." The CH zone allows retailing, office, service business, and limited manufacturing uses. The proposed project's mix of retail commercial and residential uses would be consistent with these General Plan and Zoning Ordinance land use designations for the site. The project applicant proposes to add a Planned Development (PD) zone (CH:PD) because the General Plan encourages sites larger than 40,000 square feet to be processed as a PD. Additionally, the Town Council directed staff to process a proposed change in land use from auto dealership to other uses as a PD. The density of the residential portion of the project is proposed to be 12.1 units per acre. Existing multi- family residential development located adjacent to the project's western boundary have higher densities of 18.4 units per acre and 20 units per acre. The single-family neighborhood to the northwest has a lower density of approximately 5 units per acre. The project's consistency with CEQA-relevant plans and policies is presented in Table 3. The Los Gatos General Plan and its Elements, Commercial Design Guidelines, and Los Gatos Boulevard Plan contain goals, policies, and implementation strategies that pertain to future development of the project site. However, Section 15131 of the CEQA Guidelines states that the "economic and social effects of a project shall not be treated as significant effect on the environment." Many of the goals, policies, and strategies of these plans and guidelines relate to the economic and fiscal well-being of the community as well as architectural design, and are not a subject for discussion in this CEQA document. Only those goals, policies, strategies, and guidelines that could result in a physical environmental change are listed and evaluated in Table 3. However, these policies will be considered separately by Town staff, as part of the Town's project review and approval process. The project vicinity is comprised of a mix of commercial, office, and residential uses. Adjacent parcels to the north, south, southeast, and east of the project site (also fronting on Los Gatos Boulevard) are currently in retail commercial or office use; residential development adjoins the project site to the west. The proposed residential use on the western portion of the site would be consistent with existing multi- family residential (apartment) uses located along the western project boundary and single-family residences adjacent to the northwestern project boundary (across the street). The proposed retail commercial buildings on the eastern portion of the site would be consistent with the existing mix of retail commercial and office uses to the north, east, and south. However, proposed senior apartments on the eastern portion of the site would not be consistent with adjacent office and commercial uses. Although residential use is allowed in the Mixed Use Commercial General Plan designation, it is a conditional use in the CH zone (a conditional use permit is required). In 1997, the Town completed the Los Gatos Boulevard Plan, which presents the Town's vision for the development of the Los Gatos Boulevard corridor. The Plan provides land use goals and guidelines for the Los Gatos Boulevard Plan area, which includes the project site. While the Plan does not include specific direction for land use at the project site, the proposed retail commercial component of the project would be consistent with existing commercial uses to the east, south, and southeast, while the proposed residential use would be consistent with residential uses to the north and west of the site. By locating residential uses adjacent to existing residential uses and retail commercial uses contiguous to existing retail commercial uses, the project attempts to minimize land use compatibility problems with existing uses. DECEMBER, 2010 29 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Table 3 Project Consistency with CEQA-Related Goals, Policies, and Implementing Strategies Pertinent CEQRA�S' -Related Goals, Policies, Strategies trategies Project CIYonsistency y. L,r € itroM14,444nS6hWr- -X hSi{) -dA adUsEee h�E *+, , q* L,G.1,1 To preserve promote, and protect the existing small town character and quality of life within Los Gatos. The project is considered an infill development, converting an underutilized commercial site into a development with a mix of residential and commercial uses. Residential uses on a portion of the site would be consistent with the neighboring residential uses to the north and west, while commercial uses fronting on Los Gatos Boulevard and Blossom Hill Road would be consistent with other commercial uses at this corner. Residential densities on the properties to the west range from 18.4 to 20 dwelling units per acre, while the proposed residential density would be 12.0 units per acre. L.P.1.1 Development shall be of high quality design and construction, a positive addition to and compatible with the Town's ambiance. Development shall enhance the character and unique identity of existing commercial and/or residential neighborhoods. The project proposes a high quality design and utilizes high quality materials and would be compatible with the Town's unique aesthetic character. However, Town Planning staff has expressed concerns with the senior housing component of the project, which is concentrated on the second floor of a two-story commercial building and has no dedicated open space or amenities other than those provided in the ground floor retail space, L.P.1.2 Encourage developers to engage in early discussions regarding the nature and scope of the project and possible impacts and mitigation requirements. These discussions should occur as early as possible in the project planning stage, preferably preceding land acquisition. Town staff and the project developers have worked closely for approximately 3 years to develop the proposed plan and have held several meetings including Conceptual Development Advisory Committee meetings, a Planning Commission study session, and neighborhood meetings. Through this review, the project scope and scale has been reduced and refined to the current proposed project. L.P.1.6 Encourage mixed use development consisting of residential above or behind non-residential uses in commercial areas, The proposed development provides some residential use above (limited to six senior apartments) and behind (single-family residences) the proposed commercial buildings. Town Planning staff has expressed concerns that the proposed project would not sufficiently integrate the two development areas and the residential neighborhood, and commercial development would appear as two distinct developments rather than a cohesive mixed -use project. Additionally, an exclusive single-family development would not provide an optimal transitional density between the proposed commercial development to the east and the existing condominiums and apartments to the west. L.P.1.7 In -fill projects shall contribute to the further development of the surrounding neighborhood (e.g. improve circulation, contribute to or provide neighborhood unity, eliminate a blighted area, not detract from the existing quality of life), The scale and height of the proposed project would be consistent with the existing residential neighborhood to the north and west. However, the density would be slightly lower at 12.0 dwelling units per acre where the neighboring apartments are 20 du/acre and the condominiums are 18.4 du/acre (note: single family residential is located to the northwest of the site at approximately 5 du/acre). Proposed circulation would not unduly impact the existing neighborhood, as accommodations have been made in the site layout and street Improvements are proposed to limit access to the adjacent neighborhood. Commercial redevelopment of this site would further enhance the Boulevard, However, Town Planning staff has expressed concerns with the small scale of the commercial portion of the project and believes that a larger development, with a two-story structure at the Blossom Hill corner would be more compatible with the scale and size of the other commercial sites at this intersection, as well as provide a greater amount of available commercial space for the Town. Town Planning staff has noted that a well designed, two-story with a stepped back second floor could provide visual enhancement and still preserve views of the hillsides. L.P.1,8 In -fill projects shall be designed in context with the neighborhood and surrounding zoning with respect to the existing scale and character of surrounding structures, and should blend rather than compete with the established character of the area. L.G.2.1 To limit the intensity of new development to a level consistent with surrounding development and with the Town at large. L.G.2,2 To reduce the visual impact that new construction and/or remodeling has on our town and its neighborhoods. DECEMBER, 2010 30 INITIAL STUDY - 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Table 3 (Cont'd) Project Consistency with CEQA-Related Goals, Policies, and Implementing Strategies Pertinent CEQA-Related Goals, Policies, Strategies Project Consistency n j~ ,_i ` , ? r i " a `. '�vfd' ' ,: > � � f, ... ? _;, z Laid l{se ai'vaAdf� y, nt "e. ), fic t tit 14 ✓ $P1244 r, akfttl `..>..-, �n , W-.31 4404. - L,G.2.3 To preserve the quality of the personal open space (yards) throughout the town. Town Planning staff has expressed concerns that the amount of private and public open space would not be sufficient to serve the residents. L,P,2.4 Increase building setbacks as mass and height Increase. Residences have been designed to face the street along Blossom Hill Road and Placer Oaks Road. A landscaped buffer is provided along Blossom Hill Road. Residential front yard setbacks on Placer Oaks Road and Blossom Hill Road vary, but are eight feet minimum. L.P,2.5 Maximize quality usable open space in all new developments. Town Planning staff has indicated that with a different mix of development (i.e. vertical mixed use), more and higher quality open space could be provided to the residents of the development. • L.G.3.1 To maintain the existing character of residential neighborhoods by controlling development. The proposed development is generally compatible with the existing character of the residential neighborhood; however, this is a commercial site, and Town Planning staff has indicated that a greater intensity of development should be expected. L.P.3.3 Protect existing residential areas from adjacent nonresidential uses by assuring that buffers are developed and maintained. Buffers shall be required as conditions of approval and may consist of landscaping, sound barriers, building setbacks or open space, The proposal includes good -neighbor fences, pedestrian gate connections to the commercial area, and landscaping between parking and residential side yards. Additional landscape buffers could improve the transition between the proposed commercial and residential uses and between the proposed residential uses and the existing residential uses to the west. L.P.3.4 Prohibit uses that may lead to deterioration of residential neighborhoods, or adversely impact the public safety or the residential character of a residential neighborhood. Town Planning staff finds that the project would be consistent with this policy and would not lead to the deterioration of the residential neighborhood. L.P.3,6 Develop and implement appropriate traffic controls to protect residential neighborhoods from the impacts of through traffic such as safety hazards, speeding, noise, and other disturbances, The project proposes a raised median curb on Placer Oaks Road to prohibit inbound and outbound left turns at the commercial development driveway, which would protect the neighborhood to the west from commercial traffic. Additionally a new U-Turn movement would be provided for vehicles traveling southbound on los Gatos Boulevard at the Blossom Hill intersection (currently there is no U- Turn movement allowed). L.P,4.1 Continue to encourage a variety of housing types and sizes that is balanced throughout the Town and within neighborhoods and that is also compatible with the character of the surrounding neighborhood. The proposed single-family units would be compatible In character with the surrounding neighborhood. While the project contributes to the variety of housing types throughout the Town, it should be noted that there is limited variety in the types and sizes of proposed residences. LP,4.2 Ensure that new developments area a positive addition to the Town's environment and do not detract from the nature and character of appropriate nearby established development. The project would be consistent in architectural design, residential scale and commercial character, , L.G.7.1 To provide a transition from higher intensity uses at the north end of Los Gatos Boulevard at Lark Avenue to existing residential uses at the south end of Los Gatos Boulevard. The proposed project is termed a "vertical" mixed use development,. providing a transition from areas of greater residential use to greater commercial use, Town Staff believe this commercial desirable corner is not the most appropriate location to propose a majority single family development. DECEMBER, 20 10 31 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Table 3 (Cont'd) Project Consistency with CEQA-Related Goals, Policies, and Implementing Strategies Pertinent CEQA-Related Goals, Policies, Strategies Project Consistency - L.10 fA i.w..R .Lv �"-fx1�"f �l° l t�l'i .,� wA n,,viv .VC: 3Y t tf.�.Ji G g'cy ji� Li'sS Z d �.E'i•'`< w.Pp...1,f �-v m'+.a YSC^:•1t,. S`µ,,-4 Y , iitt; «i L.G.7.6 To encourage a mixture of uses along Los Gatos Boulevard, including where appropriate, mixed -use parcels that are compatible with surrounding uses. The proposed project would provide a mixture of uses with approximately 1/2 of the site dedicated to residential use and 1/2 dedicated to commercial with associated parking. However, Town staff notes this site is located at a highly desirable commercial corner of Los Gatos Boulevard that is dominated by retail, service and office uses, L.G.7.8 To encourage pedestrian amenities, scale, and design. The project is designed with one pedestrian connection between the residential and commercial areas. L.P.7.1 New development must be designed in order to minimize adverse impacts upon adjacent residential areas. Circulation on the site has been designed to minimize impacts on the existing neighborhood. L.P.7.2 Encourage mixed uses to increase residential opportunities in commercial zones, The project is consistent with this policy. However, Town staff believes that single-family development does not provide an adequate mix of housing types. Provision of senior apartments above retail uses is consistent with the mixed -use residential opportunities encouraged in this policy. L.P.7.6 Neighborhood commercial, multi -family residential and office uses shall be concentrated south of Los Gatos- Almaden Road. The proposed development is consistent with this policy in regard to neighborhood commercial but does not propose multi -family or office uses. L.P.7.9 Establish and maintain strong boundaries between the commercial uses along Los Gatos Boulevard and adjacent residential neighborhoods. The proposed project would provide fences and landscaping as a buffer between the commercial development and proposed residential development as well as a good neighbor fence/wall along the west property line o a ><vt�mvea VP!ia S.rf! elq.- W -,; H,G.1.1 Expand the choice of housing opportunities for all economic segments of the community through a variety of housing types and sizes, including a mixture of ownership and rental housing. The project proposes two housing types, 29, 3 - 4 bedroom/2 - 3 bath single-family detached for sale residences and six, 1-bedroom/1 bath senior apartments for rent. H.1.1.4 Mixed Use Developments: Encourage mixed - use developments that provide affordable housing close to employment centers and/or transportation facilities. The proposed development would provide affordable housing in proximity to commercial uses and bus routes. However, staff is concerned that the location, size and type of BMP units provided do not adequately match the goals of the BMP program and are not consistent with the needs of the majority of people on the BMP interest list. Staff believes that integrating the BMP units within the residential development would be more in keeping with the BMP Guidelines. ME„ .:+Is CaPEemeG?t_ iv- ..:. . a_ ~ }j. 1 T.P.1.7 Require roadway improvements and dedications for any development proposal with an associated traffic impact. Mitigation measures listed in the Section 16, Transportation/Traffic, require completion of necessary road improvements, including a second eastbound left turn storage lane for Blossom Hill at Los Gatos Boulevard and increasing the southbound left turn storage at Blossom Hill and Los Gatos Boulevard by reconfiguring the median. t_ __.. ._ _ _(YAW n;sue 5_- 0,P.5.1 Promote private open space in all planning decisions. The project includes private open space consisting of residential side yards of approximately 4 feet, front porches and some rear yards. Given that this is a mixed -use development, private open space is expected to be limited, while public open spaces are expected to be more generous. DECEMBER, 2010 32 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Table 3 (Cont'd) Project Consistency with CEQA-Related Goals, Policies, and Implementing Strategies Pertinent CEQA-Related Goals, Policies, Strategies Project Consistency y��,` N� {` "' fi':� r. C A ''' k'' c u*3iwr�y,�t Yw t 71 ,V + ;'�33 t�ti tl G(i�Stf `. O en S ace Ele aonf d j ,, li P ` t?.. in ti -5 t..P....,P. .,. ,. �!l.r...s,..,..,.i.. E_ r 43 ht. .. .. .+f..... O.P.5.4 Provide permanent common open space in high-0.02 density developments. The project includes a common open space area of approximately acre consisting of a decomposed granite seating area with three benches located adjacent to Lot 6 near some guest parking spaces. Town staff is concerned that due to its location on the site it will not be well utilized by residents. O.P,5.5 Encourage the use of innovative, development techniques which will provide open space within individual developments, public private. The proposal provides limited private open space within the residential properties, and very little public open space within the residential development. Public open spaces within the commercial development include large patios with outdoor seating. j a �' � t� . 7 x_'� .. � � -. :-t .. r r �. a• j Ron ati`log;�'Ele [q + asr ., ,��iww wAea ,,,, u s Y /fit ,, , en � 's 3.f� 4`, �y}- ' . C.P.3.7 Maintain street trees, plant additional street trees and encourage preservation and planting of trees on private property, The majority of existing street trees are proposed to be retained and additional street trees and landscaped areas are proposed. { ,!{rr'' �-`�� { ',i,4 a4 tvBP'n. d5i stax �y �,aes�vss� r t k �M Noise`L'�eRie 3PSv'x"H+R _. r s ro. ryG" T f -= S/�rsa'gtY�Y.�%•33f dP.'.:1•6 re _ t1 � � i YOE �{l i, }?s� f �V s'�.....: N.P.1.13 Noise Level: The Town shall require all noise sensitive developments hall adjacent or within an area where noise levels exceed community aspirations to include a noise study and recommendation for reducing noise impact to acceptable level. A detailed noise study was completed for the residential portions of the project. Noise levels at proposed residences located adjacent to Los Gatos Boulevard and Blossom Hill Road would be subject to noise levels that exceed applicable thresholds, a significant impact. Required noise abatement mitigation measures are outlined in Section 12, Noise, and would reduce noise impacts to less than significant. "'k:"- c / a 1: H 4 uric tMYttS°'i .. +4� � u .. CommuniyY "4 i' APhAHSYr++ 7 f a 1 t 4' De 1 n Elg enter N , e . } +� ', h 3 ,4- CD.P.1.4 Promote and protect view sheds. The project's impact on viewsheds would be less than significant (see Section 1, Aesthetics). CD.P.1,5 Avoid abrupt changes in scale and density. Within the proposed site plan, abrupt changes in scale and density are avoided between the commercial and the residential portion of the development. However, Town staff believes that the commercial development could be taller at the corner of Los Gatos Boulevard and Blossom Hill and the density of the residential portion could be higher. More land area could be devoted to the commercial development and less to the residential if attached residential units were proposed, rather than exclusively detached single-family units. CD.P.1.8 Building elements shall be in proportion with those traditionally in the neighborhood. The project design would be consistent with this policy. CD,P.1.9 Building, landscape and hardscape materials shall be used that will reinforce the sense of unity of a neighborhood and blend with the natural setting. The project design would be consistent with this policy. CD.P.1.14 Minimize visual impacts of lighting The project's lighting impact would be less than significant (see Section 1, Aesthetics). CD.P.1.15 Utility connections and meters shall be located as to be visually unobtrusive from the street. The project design would be consistent with this policy. a .. 2020 Draft Gene A Ptai) �, - �. s �*` tFr 46 LU-12 To ensure an appropriate mix of land use types along Los Gatos Boulevard in order to maintain the economic vitality of the corridor and continue to serve the needs of Town residents. The project proposes a mix of single family residential and mixed use commercial land uses consistent with this goal. LU-13 To promote appropriate and compatible development along Los Gatos Boulevard that compliments the whole Town and serves residents and families, Refer to L.G.7.1 DECEMBER, 2010 33 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Table 3 (Cont'd) Project Consistency with CEQA-Related Goals, Policies, and Implementing Strategies Pertinent CEQA-Related Goals, Policies, Strategies Project Consistenc �� tin `J.jffivau`r,: - .4 'Ara �t�+t`'� ktY�".T"'fK.5,.'i 3 _yt � try :4t ,y �� 2020 graft Gene�alt LaOa cope,'aq, ' s. ` �? + s't.: CD-1 Preserve and enhance the Town's character through exceptional community design. The overall design of the commercial development is consistent with this policy. The residential portion of the development is not consistent as described in the review by Cannon Design Group in the Aesthetics section of this document. CD-2 To limit the intensity of new development to a level that is consistent with surrounding development and with the Town at large. The project's development intensity would be consistent with this goal, CD-7 To preserve the quality of the private open space throughout the Town. Refer to 0.P.5.1, O.P. 5.4 and O.P.5.5. '0a S =-Xfi nsa ye Y a y a F az�g` *, , .z .4 mime a Desrg Gu del es�`r f -i F} �§ s $S�w�SYi.� a 5.A.2.1 Los Gatos Boulevard setbacks should be substantially landscaped. The project would provide approximately 15 feet of landscaped setback adjacent to the commercial buildings along Los Gatos Boulevard and Blossom Hill Road. 5.A.2.2 Automobile entries to projects and individual buildings shall be given special treatment with paving and landscaping. The project would provide bulb -outs, decorative sidewalk paving, and landscaping, consistent with this guideline. 5,A.2.3 All projects shall have a clear and direct walkway between fronting streets and one or more of the primary building entries. The project would provide walkways which connect the buildings to the street frontage and sidewalks. 5.A.2.4 Parking lots should be located behind or to the side of buildings facing Los Gatos Blvd, whenever possible. Proposed parking lots for the commercial portion of the project would be located behind proposed commercial buildings, consistent with this policy. 5.A.2.5 Parking lots shall be heavily landscaped. Landscaping is proposed in proposed parking lots, consistent with this policy. 5.A.2.6 Projects located on corner parcels at signalized intersections should incorporate major design features on the intersection corner. Although the individual buildings are considered to be architecturally well -articulated. Town Planning staff and Cannon Design Group indicate that this corner would benefit from a two-story building with a stepped second floor office above retail to provide a more compatible sense of scale. The building corner is architecturally detailed and articulated consistent with this policy. 5.A,2.7 Projects backing up to residential neighborhoods should be sensitive to their potential impacts on the residents. The residential development has been designed so that the rear elevation the proposed residences are adjacent to the property line with the condominium and apartment developments to the west. Visual breaks would be provided by a parking area between lost 11 and 12. On Placer Oaks Road and Blossom Hill Road, proposed residences would be oriented with their front doors facing those streets. 5.A.3.1 Integrate the design of all buildings in larger projects. The development is divided into a residential subdivision and a commercial development. The Town Staff believes that the residential buildings are not architecturally similar and are not well integrated in terms of form and style with the proposed commercial development or the surrounding neighborhood (Cannon Design Group), 5.A.3.2 Design buildings to relate to the unique qualities of Los Gatos. 5.A.3.3 Provide well defined project and building entries. Well defined project and building entries are proposed for the commercial buildings. 5.A.3.4 Relate architectural focal point elements to pedestrian scale rather than automobile scale, Focal points such as patios proposed within the retail development and patterned walkways proposed within the parking lot would help create a pedestrian scale. 5.A.3.5 Design all projects with a strong commitment to human scale. The proposed buildings are designed and detailed at a human scale. DECEMBER, 2010 34 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HIL); ROAD Table 3 (Cont'd) Project Consistency with CEQA-Related Goals, Policies, and Implementing Strategies Pertinent CEQA-Related Goals, Policies, Strategies Project Consistency 5,A.3,6 Select colors to be compatible with other projects along the Boulevard. Proposed materials include; clay tile roof, stone veneer and stucco exterior surfaces, wood shutters and roof details, wood trellis and lattice, and wrought iron details. LGB.2 Major entrances to the Boulevard will have special landscaping, architecture, and/ or artistic displays that announce Los'Gatos as a distinct area. The project provides approximately 15 feet of landscaped setback adjacent to the commercial buildings along Los Gatos Boulevard and Blossom Hill. LGB,3 Land Uses will include 'the following: open space; community recreation; auto related, regional and neighborhood commercial; retail entertainment; and sufficient housing to support regional transportation centers. These uses will be implemented in such a way to keep the transition from the higher density mixed use area In the north to a mixture of residential and commercial clusters, and then to existing residential In the south. The proposed project would be consistent with this policy in that the mix of retail and residential uses at this location on Los Gatos Boulevard provides a mixed -use development in a transition area where the Boulevard is beginning to change from higher density commercial in the north to residential in the south. However, this intersection is a gateway to the Boulevard, is located at a corner that is developed with higher density commercial uses, and the site is of adequate size to provide a greater amount of commercialdevelopment while still providing a mixed use residential project, ' LU.G.4 Provide a transition from higher density uses at the north end of Los Gatos Boulevard to existing residential uses at the south end of Los Gatos Boulevard. LU.G.3 Encourage a mixture of uses along Los Gatos Boulevard that are compatible with surrounding uses. The proposed mixed -use project would include retail commercial and residential uses, which would be compatible with surrounding uses. PIP 1 Proposals shall be designed to fit the natural conditions of a site and respect scenic corridors. View shed preservation has been accommodated through site design and keeping building heights low. Town Planning staff notes, however, that view sheds could still be preserved if a larger commercial development were proposed. PI.P.3 Proposals shall be designed to minimize interference with the privacy, quiet, and views of surrounding residential properties. The project would be consistent with this policy since the western portion of the project site would be developed with single-family residences, which would be compatible with adjacent residential uses to the west. Views from surrounding properties would not be blocked by project structures. However, the location of this property adjacent to two busy streets does not provide the quiet environment typically associated with single-family residential neighborhoods. PI.P.6 Pedestrian access to buildings and sites shall be encouraged. The project is designed with a pedestrian walkway between the residential and commercial areas. This would encourage pedestrian access from residences to commercial uses on the site as well as across Los Gatos Boulevard and Blossom Hill Road. N.G,1 Encourage pedestrian activity at and movement across Los Gatos Blvd. at key points along the Boulevard. N,G,3 Connect and unify the streetscape on both sides of Los Gatos Boulevard As described in Section 1, Aesthetics, the proposed commercial buildings' single -story and two-story elements would be similar to the retail commercial and office buildings to the north and south of the project site along Los Gatos Boulevard. The proposed project's design would contrast with the Cornerstone and King's Court shopping centers on the east side of Los Gatos Boulevard on either side of Blossom Hill Road. These retail centers consist of single -story commercial buildings with parking facilities located along Los Gatos Boulevard and commercial buildings situated to the rear of the properties, relative to Los Gatos Boulevard. However, the project's commercial buildings would be more similar in design with the +1-story commercial center located to the south across Blossom Hill Road, where parking is located behind the center. DECEMBER, 2010 35 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Table 3 (Cont'd) Project Consistency with CEQA-Related Goals, Policies, and Implementing Strategies Pertinent CEQA-Related Goals, Policies, Strategies Project Consistency 01.401.aa ..s The project proposes a focal point - the outdoor patios proposed on N,G.4 the west sides of both commercial buildings, which would be a gathering point. Source: H. Bradley, Town of Los Gatos Community Development Department (November 2010) Establish activity focal points on private property along Los Gatos Boulevard. and public Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 11. Mineral Resources - Would the project: a) Result in the loss of availability of a known mineral resource that would be of value to the region and the residents of the state? X b) Result in the loss of availability of a locally -important mineral resource recovery site delineated on a local general plan, specific plan or other land use plan? X The Los Gatos General Plan does not identify any regionally or locally -important mineral resources on the project site or in its vicinity. Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 12. Noise - Would the project result in: a) Exposure of persons to or generation of noise levels in excess of standards established in the local general plan or noise ordinance, or applicable standards of other agencies? X b) Exposure of persons to or generation of excessive groundborne vibration or groundborne noise levels? X c) A substantial permanent increase in ambient noise levels in the project vicinity above levels existing without the project? X d) A substantial temporary or periodic increase in ambient noise levels in the project vicinity above levels existing without the project? X e) For a project located within an airport land use plan or, where such a plan has not been adopted, within two miles of a public airport or public use airport, would the project expose people residing or working in the project area to excessive noise levels? X DECEMBER, 2010 36 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact X f) For a project within the vicinity of a private airstrip, would the project expose people residing or working in the project area to excessive noise levels? Construction Noise. Project construction would result in temporary short-term noise increases due to the operation of heavy equipment. Construction noise sources range from about 76 to 85 dBA1° at 50 feet for most types of construction equipment with slightly higher levels of about 88 to 91 dBA at 50 feet for certain types of earthmoving and impact equipment. If noise controls are installed on construction equipment, the noise levels could be reduced by 1 to 16 dBA, depending on the type of equipment. The potential for construction -related noise increases to adversely affect nearby residential receptors would depend on the location and proximity of construction activities to these receptors. The Town Noise Ordinance (Chapter 16) restricts construction activities to the hours of 8:00 a.m. to 8:00 p.m. on weekdays and 9:00 a.m. to 7:00 p.m. on weekends and holidays. This ordinance also limits noise generation to 85 dBA at the property line or 85 dBA at 25 feet. Adjacent uses include condominiums and the Valley Oaks Apartments located 15 to 70 feet from the western project boundary, two single-family homes located across Placer Oaks Road, approximately 90 feet from the northern project boundary, an office building located approximately 80 feet from the northern project boundary, as well as retail commercial buildings located approximately 150 feet from the eastern project boundary and 100 feet from the southern project boundary. There is also a combination of masonry, wood, and chainlink fencing located along the western project boundary. While construction equipment is expected to operate at least 50 feet from adjacent condominiums and apartments most of the time, there is one area in the southwest corner of the site where construction equipment could operate as close as 15 to 20 feet from existing condominiums and apartments for short periods. At 50 feet, the ordinance noise limit would result in maximum noise levels of 79 dBA at the closest condominiums to the northwest, while at 15 to 20 feet, Valley Oaks Apartments to the southwest would be subject to maximum noise levels of up to 89 dBA when equipment operates adjacent to the southwestern project boundary. Temporary disturbance (e,g., speech interference) can occur if the noise level in the interior of a building exceeds 45 to 60 dBA."" To maintain such interior noise levels, exterior noise levels at the closest residences (with windows closed) should not exceed 70 to 80 dBA and this exterior noise level is used as a significance threshold or criterion. It appears that construction noise levels could be maintained below 80 dBA most of the time except when equipment is operated in the southwest corner adjacent to the project boundary. Construction equipment would operate as close as 15 to 20 feet from the existing Valley Oaks Apartments to the southwest for a short period, but would be setback more than 50 feet from other adjacent uses to the west, north, east, and south. Due to the proximity of existing apartments to the southwest, construction -related noise increases could be significant periodically, and implementation of the following measure, in conjunction with enforcement of time restrictions and noise level standards contained in the Town Noise Ordinance, will be required to reduce temporary noise impacts to a less -than -significant level: 'a Environmental noise is measured in units of dBA. The dBA, or A -weighted decibel, refers to a scale of noise measurement that approximates the range of sensitivity of the human ear to sounds of different frequencies. " In indoor noise environments, the highest noise level that permits relaxed conversation with 100% intelligibility throughout the room is 45 dBA. Speech interference is considered to become intolerable when normal conversation is precluded at 3 feet, which occurs when background noise levels exceed 60 dBA (U.S. Environmental Protection Agency, Information on Levels of Environmental Noise Requisite to Protect Public Health and Welfare with an Adequate Margin of Safety (Condensed Version). 1974). DECEMBER,2010 37 INITIAL STUDY — 16005 LOs GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD 12. To minimize construction noise impacts on existing adjacent residences to the west, existing boundary fencing shall be retained throughout the noisier earthmoving phase of construction or proposed fencing along this boundary shall be constructed as early as possible (prior to project grading activities if To maximize the fence's noise attenuation effects, proposed fencing shall be solid with no gaps, cracks, or openings (e.g., high quality air -tight tongue -and -groove, board and batten, or shiplap design). Impacts associated with groundborne vibration and noise are typically less than significant for most types of construction activities (i.e. vibration levels generated by most types of construction equipment would not exceed threshold levels for cosmetic damage to structures). However, operation of impact or vibration pile drivers or large truck -mounted compactors can generate vibration levels that would disturb neighbors and could result in cosmetic damage to adjacent structures at distances of less than 50 feet. Operation of such equipment as part of project construction would not be required. Therefore, impacts associated with groundborne vibration and noise are expected to be less than significant. Operational Noise. Sources of noise associated with the proposed retail commercial use would include delivery trucks and associated loading and unloading activities, parking cars, garbage trucks and refuse bins as well as rooftop air conditioning and heating units. The proposed loading space would be located on the north end of the parking lot adjacent to Placer Oaks Road, approximately 100 feet from the office building to the north, 280 feet from the closest existing residence to the northwest, 50 feet from the closest proposed single-family residence to the west, and approximately 10 feet from the closest senior apartment to the east. Noise levels due to loading activities would be variable, but typically do not exceed 60 dBA (Leq) at 100 feet for loading activities on loading docks. Since small retail uses in proposed commercial buildings would not require loading docks and only small delivery trucks are expected, noise from loading/unloading activities would be less and not expected to generate exceed existing or future ambient noise levels. Two trash enclosures are proposed, one at the northwest corner of Building One (adjacent to Placer Oaks Road) and a second at the southwest corner of Building Two (adjacent to Blossom Hill Road). The northerly trash enclosure would be located directly below the proposed senior apartment Unit 1, while both enclosures would be approximately 60 feet from the closest single-family residences to the west. Section 16.20.055 of the Noise Ordinance prohibits refuse collection with a refuse collection vehicle between the hours of 6:00 p.m. and 6:00 a.m. in a residential zone. Since the western portion of the project site is located in a residential zone, these time restrictions on refuse collection would not apply to the commercial portion of the project and it is possible that disturbance of residents living in the westernmost senior apartments and easternmost single-family homes would be subject to disturbance in the early morning hours from trash collection activities, a potentially significant impact. To ensure that such noise disturbance is avoided, the following measure shall be required to reduce potential operational noise impacts to less than significant: 13. As a condition of project approval, the Town will require the commercial -related trash collection activities to comply with Section 16.20.055 of the Noise Ordinance, which prohibits refuse collection with a refuse collection vehicle between the hours of 6:00 p.m. and 6:00 a.m. in a residential zone. When the Los Gatos Noise Ordinance noise limits are applied to the project site, the ordinance noise limits would be 55 dBA from 6 a.m. to 1 p.m., 59 dBA from 1 p.m. to 10 p.m., and 48 dBA from 10 p.m. to 6 a.m. Project operations, including rooftop equipment and loading activities, will be required to comply with these ordinance noise limits. Noise abatement measures (e.g., use of quieter equipment, provision of equipment enclosures or sound barriers, or use of parapet roof design) will be incorporated into the project as required in order to comply with these noise limits. DECEMBER,2010 38 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Project -related traffic increases on Placer Oaks Road would also result in long-term noise increases along this roadway. Based on traffic volumes presented in Section 16, Transportation and Traffic, project - related traffic increases along existing neighborhood streets would increase noise levels by less than 1 dBA, which would be less than significant. In general, noise increases of 3 dBA are barely perceptible to most people. When traffic increases on Placer Oaks Road due to this project are considered with estimated traffic increases from the proposed Placer Oaks project,12 cumulative traffic increases on Placer Oaks Road would be approximately 1 dBA, also a less -than -significant noise increase. Noise Compatibility of Proposed Use. A detailed noise study was prepared by Edward L. Pack Associates, Inc. (ELPA) in October 2010, and this report is included in Attachment 7. As part of this study, a continuous, 24-hour noise measurement was taken at two locations on the site: 128 feet from the centerline of Los Gatos Boulevard and 50 feet from the centerline of Blossom Hill Road. The results of these measurements indicate that noise levels at 64 dB (DNL) 19 at 128 feet from the Los Gatos Boulevard centerline (daytime Leg14 of 60 to 65 dBA and nighttime Ley of 50 to 58 dBA) and 65 dB (DNL) at 50 feet from the Blossom Hill Road centerline (daytime Leq of 60 to 66 dBA and nighttime Ley of 47 to 58 dBA). Noise exposure of proposed uses are estimated to be as follows: ■ Senior apartments would be exposed to noise levels of 67 dB (DNL) at the closest balconies and exterior walls. Under future traffic conditions, the noise exposure is expected to increase to 68 dB (DNL). • Single-family homes located adjacent to Blossom Hill Road would be exposed to noise levels of up to 64 dB (DNL) on the first floor and 65 dB (DNL) on the upper floor. Under future traffic conditions, the noise exposure is expected to increase to 65 dB (DNL) and 66 dBA (DNL), respectively. • Balconies of single-family homes located closest to Blossom Hill Road (79 feet from the centerline) would be exposed to noise levels of 67 dB (DNL). 'Under future traffic conditions, the noise exposure is expected to increase to 68 dB (DNL). • The common open space area in the residential portion of the project would be subject to noise levels of 47 to 50 dB (DNL) or 45 to 48 dBA (Leg(24)) under existing conditions and 48 to 51 dB (DNL) or 46 to 49 dBA (Leq(24)) under future traffic conditions. ■ Exterior noise exposures in the patio of Building 1 (northerly building) would be subject to noise levels of 53 to 56 dBA (Leg(24)) under existing conditions and 54 to 57 dBA (Leg(24)) under future traffic conditions. • Exterior noise exposures in the patio of Building 2 (southerly building) would be subject to noise levels of 51 to 55 dBA (Legt24l) under existing conditions and 52 to 56 dBA (Leq(24)) under future traffic conditions. 12 Geier & Geier Consulting, Inc., Initial Study for Placer Oaks, Placer Oaks Road, Los Gatos, California, June 2009. 13 Because community receptors are more sensitive to unwanted noise intrusion during the evening and at night, state law requires that, for planning purposes, an artificial decibel (dB) increment be added to quiet time noise levels in a 24-hour noise descriptor called the Community Noise Equivalent Level (CNEL). CNEL adds a 5-dB "penalty" during the evening hours (7:00 p.m. to 10:00 p,m.) and a 10-dB penalty during the night hours (10:00 p.m, to 7:00 a,m,), Another 24-hour noise descriptor, called the day -night noise level (DNL), is similar to CNEL. While both add a 10-dB penalty to all nighttime noise events between 10:00 p.m. and 7:00 a.m„ DNL does not add the evening 5-dB penalty. In practice, DNL and CNEL usually differ by less than 1 dB at any given location for transportation noise sources. Both also use the A -weighted dB scale, dBA. 14 Leq: The energy equivalent noise level, a steady-state energy level which represents the acoustical energy of a given measurement period that is equal to the actual time -varying sound level measured during the same period. DECEMBER,2010 39 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD To determine noise compatibility of the proposed use, noise levels at the site were compared to the Town's outdoor noise goals specified in the Noise Element of the General Plan for new commercial and residential developments. Policy N.P.1.7 of the Noise Element specifies outdoor noise limits of 70 dBA (Leq(24) or Leg averaged over 24 hours) for commercial uses, 55 dBA (Leg(24)) for open space (developed park) uses, and 55 dB (DNL) for residential uses, stating that these noise limits represent the "long range community aspirations" and acknowledging that such goals may not be attainable at this time. When existing and future noise exposures at proposed uses are compared to these noise goals, proposed senior apartments and single-family homes would be subject to existing and future noise levels that exceed the Town's 55-dB (DNL) noise goal. The proposed common open space park in the residential portion of the site would be subject to existing and future noise levels that would not exceed the Town's 55-dBA (Legt24)) noise goal for open space (developed parks) areas. The proposed commercial buildings would be subject to existing and future noise levels that would not exceed the Town's 70-dBA (Leq(24)) noise goal for commercial uses. The Town Noise Element does not specify a noise goal that could appropriately be applied to the proposed patios on the west side of both commercial buildings, but if the commercial noise goal were to be applied, existing and future noise levels at the proposed patios would meet the 70-dBA (Leq(24)) noise goal. Although the Town's 55-dB (DNL) residential noise goal would not be met at proposed residential uses, the Town's Noise Element (Policy 9) states that these noise limits represent the "long range community aspirations" and acknowledges that such goals may not be attainable at this time. Such goals may be more appropriate for residential neighborhoods that are located away from major noise sources (such as freeways or arterial roadways). In areas where the Town's noise goal cannot be met, the Town also uses the land use compatibility noise guidelines included in the Town's Noise Element as a criterion for defining significance of a noise impact under CEQA. These noise guidelines define noise limits as follows: ■ Single-family Residential Uses: normally acceptable up to 60 dB (DNL) in exterior living areas (yards and common open space); conditionally acceptable between 55 and 70 dB (DNL); normally unacceptable between 70 and 75 dB (DNL); and clearly unacceptable above 75 dB (DNL).15 ■ Multi -family Residential Uses: normally acceptable up to 65 dB (DNL) in exterior areas (balconies); conditionally acceptable between 60 and 70 dB (DNL); normally unacceptable between 70 and 75 dB (DNL); and clearly unacceptable above 75 dB (DNL). • Commercial Uses: normally acceptable up to 70 dB (DNL); conditionally acceptable between 55 and 70 dB (DNL); normally unacceptable between 70 and 75 dB (DNL); and clearly unacceptable above 75 dB (DNL). Noise levels up to 70 dB (DNL) are considered acceptable for commercial uses. In addition, Title 24, Part 2 of the California Code of Regulations contains requirements for construction of new hotels, motels, apartment houses, and dwellings other than detached single-family dwellings intended to limit the extent of noise transmitted into habitable spaces. For limiting noise transmitted between adjacent dwelling units, Title 24 standards specify the extent to which walls, doors, and floor - ceiling assemblies must block or absorb sound, requiring a Sound Transmissions Class (STC) rating of 50 or higher in common walls and floor/ceiling assemblies. As design details for the interior partitions of the 15 Under Normally Acceptable conditions, no special noise insulation requirements are needed. Under Conditionally Acceptable, a detailed noise analysis and needed noise attenuation design measures are required, but conventional construction, but with closed windows and fresh air supply systems or air conditioning will normally suffice. Where noise levels are considered Normally Unacceptable, new construction is generally discouraged but if it proceeds, a detailed noise study and needed noise attenuation design measures are required. DECEMBER,2010 40 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD project are not currently available, an evaluation of the interior partitions has not been made. For limiting noise from exterior sources, Title 24 specifies an interior standard of 45 dB (CNEL or DNL) in any habitable room with all doors and windows closed and requires an acoustical analysis demonstrating how dwelling units have been designed to meet this interior standard where such units are proposed in areas subject to noise levels greater than 60 dB (CNEL or DNL). The ELPA noise study fulfills the Title 24 requirement of an acoustical study. When compared to the above land use compatibility noise guidelines and Title 24, project consistency would be as follows: • Senior Apartments: Noise levels at balconies of the four units facing Los Gatos Boulevard (Units 1 to 4) would exceed the 65 dB (DNL) noise guideline for multi -family residential uses by 3 dB and apartment interiors exceed the Title 24 requirement by 8 dB, a significant noise impact. • Single-family Homes: Exterior noise levels at single-family residences located closest to Blossom Hill Road would exceed the 60 dB (DNL) noise guideline for single-family residential uses by up to 3 dB, a significant noise impact. ■ Common Open Space Area: Noise levels in the common open space area in the residential portion of the project would not exceed the Town's 55-dBA (Leq(24)) for open space (developed park) uses, a less -than -significant noise impact. • Patios of Buildings 1 and 2: Noise levels at both patios would not exceed the Town's 70-dBA (Leq(24)) noise goal for commercial uses, a less -than -significant noise impact. To reduce the significant noise impacts identified above for the senior apartments and single-family residences, the following noise attenuation measures will be incorporated into the project design to ensure that acceptable interior noise levels are achieved, reducing identified impacts to a less -than -significant level: 14. To meet the Town's 55-dB (DNL) residential noise goal, balconies and decks shall be completely enclosed so that these spaces were no longer exterior spaces. If such a design is undesirable, the following design requirements shall be implemented to achieve Town -recommended exterior noise guidelines in usable outdoor spaces on proposed senior apartments and single-family residences: a. To achieve compliance with the Town's 65-dB (DNL) exterior noise guideline at proposed senior apartments, 42-inch high acoustically -effective railings shall be constructed on the balconies of Units 1 to 4 along Los Gatos Boulevard. The balcony railing height is in reference to the nearest balcony floor elevation. To achieve an acoustically -effective balcony railing, it must be constructed air -tight (i.e. without cracks, gaps, or other openings) and must provide for long-term durability, including the balcony floor. The railings can be constructed of masonry, wood, concrete, stucco, metal or a combination thereof, and must have minimum surface weight of 1.5 pound per square foot. If wood fencing is used, homogenous sheet materials are preferable to conventional wood fencing as the latter has a tendency to warp and form openings with age. However, high quality, air -tight tongue -and -groove, board and batten, or shiplap construction can be used, provided that the construction is air -tight and the minimum surface weight is met. Translucent materials, such as glass, Lexan, or Plexiglas, may be incorporated into the barriers to provide for light and views, however, they must have a minimum thickness of 3/16 inches to meet the minimum surface weight requirement. Downspouts and scuppers are preferable over sheet draining. All connections with DECEMBER, 2010 41 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD posts, pilasters, and the building shells must be sealed air -tight. No openings are permitted between the upper railing components and the balcony floor. b. To achieve compliance with the Town's 60-dB (DNL) exterior noise guideline at side and rear yards of proposed single-family residences, six-foot high acoustically -effective barriers between proposed homes on Lots 1 through 5 and along the west side of Lot 5, terminating near the garage (see Figure 1 of Attachment 7 for the locations of the recommended noise -control barriers). The barriers shall connect air -tight to the sides of the homes. The barrier height is in reference to the nearest building pad elevation. To achieve an acoustically -effective barrier, it must be constructed air -tight, i.e., without cracks, gaps or other openings, and must provide for long term durability. The barriers can be constructed of masonry, wood, concrete, stucco, metal, earth berm or a combination thereof and must have a minimum surface weight of 2.5 pounds per square foot. If wood fencing is used, homogeneous sheet materials are preferable to conventional wood fencing as the latter has a tendency to warp and form openings with age. However, high quality, air -tight tongue -and - groove, board and batten or shiplap construction can be used, provided that the construction is air -tight and the minimum surface weight is met. Gates may be incorporated into the barriers; however, they must meet the minimum surface weight and height requirements and must fit tight when closed. Astragals or stops shall be used over the hinge jamb and closure jamb gaps. A gap under a gate may be no more than 1-inch high. All connections with posts, pilasters and the building shell must be sealed air -tight. No openings are permitted between the upper barrier components and the ground. 15. To achieve the acceptable interior noise levels of 45 dB (DNL) at proposed senior apartments (Title 24) and single-family residences, the following noise control measures shall be incorporated into the project design: a. All windows and glass doors of living spaces that are proposed within 270 feet of the Los Gatos Boulevard centerline and with a direct or side view of the roadway (Units 1 to 5) shall be kept closed at all times. All windows and glass doors on these units shall have a minimum Sound Transmission Class (STC) rating of 28. Mechanical ventilation shall be provided in these units. b. All windows and glass doors of living spaces that are proposed within 120 feet of the Blossom Hill Road centerline and with a direct or side view of the roadway (Lots 1 to 5) shall be kept closed at all times. All windows and glass doors on these units shall have a minimum Sound Transmission Class (STC) rating of 28. Mechanical ventilation shall be provided in these units. When windows and doors are maintained closed for noise control, some type of mechanical ventilation to assure a habitable environment must be provided. The mechanical ventilation requirements are specified in the Uniform Building Code (UBC) and described in Appendix B of the ELPA study, which is included as Attachment 7. The windows that are specified to be maintained closed are to be operable, as the requirement does not imply a `fixed" condition. All other windows of the project and all bathroom windows may have any type of glazing and may be kept opened as desired unless the bathroom is an integral part of a living space without a closeable door. In addition to the required STC ratings, the windows and doors shall be installed in an acoustically - effective manner. To achieve an acoustically -effective window construction, the sliding window panels must form an air -tight seal when in the closed position and the window frames must be caulked to the wall opening around their entire perimeter with the non -hardening caulking compound DECEMBER, 2010 42 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD to prevent sound infiltration. Exterior doors must seal air -tight around the full perimeter when in the closed position. The acoustical test report of all sound -rated windows and doors should be reviewed by a qualified acoustician to ensure that the chosen windows and doors will be adequately reduce traffic noise to acceptable levels. Many dual -pane windows and glass door assemblies have inherent noise reduction problems in the traffic noise frequency spectrum due to resonance that occurs within the air space between the window lites, and the noise reduction capabilities vary from manufacturer to manufacturer. Issues (and Supporting. Information Sources) Potentially Significant Impact Potentially Significant • Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 13. Population and Housing - Would the project: a) Induce substantial population growth in an area, either directly (for example, by proposing new homes and businesses) or indirectly (for example, through extension of roads or other infrastructure)? X b) Displace substantial numbers of existing housing, necessitating the construction of replacement housing elsewhere? X c) Displace substantial numbers of people, necessitating the construction of replacement housing elsewhere? X A detailed evaluation of the population and housing conditions in the San Francisco Bay area, including the Town of Los Gatos, has been prepared by the Association of Bay Area Governments (ABAG) as part of its Projections 2009 assessment of population, housing, and employment for the region. This ABAG report serves as a basis for the formulation of the Town's 2007 — 2014 Housing Element. ABAG's Projections 2001 provided the background data used for the Town's 2002 — 2007 Housing Element. The 2007 — 2014 Housing Element and its supporting technical analyses are incorporated herein by reference. As discussed in the Housing Element, regional governments are required by State law to estimate and allocate the number of housing units needed among each member community. This estimated number of housing units is called the Regional Housing Needs Allocation (RHNA) and is broken down by income level with the goal of fairly distributing affordable housing throughout the region. The Town of Los Gatos is located in Santa Clara County, one of the nine Bay Area counties that are represented by ABAG. ABAG estimates the total RHNA for Los Gatos to be 562 housing units for the planning period starting July 1, 2007 and ending June 30, 2014. The RHNA number presented in the Housing Element was adjusted to account for residential units built, under construction, or approved since 2007. The adjusted RHNA is currently 521 dwelling units. The technical study prepared in support of the Housing Element includes an inventory and analysis of land available for potential use in residential development, either entirely as residential or as part of a mixed -use project. The study identifies seven sites, including the proposed project site (Swanson Ford property), as potential locations for new residential uses. It should be noted that most of the candidate sites have been previously developed with other uses and would be converted to residential or mixed uses. The technical study indicates that the seven sites have a realistic development capacity of 611 dwelling units. This capacity exceeds the ABAG-identified RHNA, as adjusted, by 90 units. Consequently, the DECEMBER, 2010 43 INITIAL STUDY — 16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Town has sufficient available sites to meet its share of allocated regional housing demand for the planning period of 2007 to 2014. The proposed mixed -use development of the project site includes residential use that is incorporated into the residential land inventory used for the 2007 —2014 Housing Element. The Element's technical study provides a discussion of the residential uses planned for this site (Swanson Ford) and recognizes that the proposed project encompasses development of six senior apartments. To the extent that the proposed project contributes additional residential uses to the anticipated housing needs within the community through 2014, the project would be consistent with the level of growth planned for Los Gatos through 2014. Since the proposed project would replace an auto dealership with 23,267 s.f. of retail commercial space, six senior apartments, and 29 single-family homes, the project would increase the Town's population. The proposed project could generate approximately 80 additional residents. The project's addition of 80 persons would represent a 0.3% increase over the Town's current population of 28,810, as indicated in the technical study for the Housing Element. ABAG projects that Los Gatos' population will increase to 30,000 by 2020, a growth rate of 1 percent that would be consistent with the growth rate of the past 30 years. Such increases in population would not represent a significant increase in local or regional population. The project would not be considered growth -inducing, since the project would involve redevelopment of an existing developed parcel and the project would not extend roads or infrastructure to any adjacent properties. The General Plan encourages redevelopment of the project area since it designates the project site and surrounding properties as "mixed use commercial." Although the project helps to fulfill the Town's desire for redevelopment of this area as indicated by the General Plan, the project is only partially consistent with the economic -related General Plan and Los Gatos Boulevard Plan goals and policies for the site. Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 14. Public Services - a) Would the project result in substantial adverse physical impacts associated with the provision of new or physically altered governmental facilities, need for new or physically altered governmental facilities, the construction of which could cause significant environmental impacts, in order to maintain acceptable service ratios, response times or other performance objectives for any of the public services: Fire protection? X Police protection? X Schools? X Parks? X Other public facilities? X Services are currently provided to the project site as well as to adjacent commercial and residential uses. No significant increase in demand on public safety services is expected to be required for the proposed project since services were previously provided to the former auto dealership use on the site. DECEMBER, 2010 44 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD The Santa Clara County Fire Department has reviewed the project plans for site access and water supply, and the project will be required to meet Department requirements for minimum fire flow, automatic fire sprinklers, hydrant spacing/location (including three private on -site hydrants), building access requirements, etc.t6 The project will be required to install an automatic fire sprinkler system, appropriate fire lane marking, and fire department emergency access key lock box. Adequate fire apparatus (engine) access will need to be provided on any access roads, which includes 20-foot pavement width, a minimum turning radius of 36 feet outside and 23 feet inside, and a maximum slope of 15 percent. The Fire Department also requires potable water supplies to be protected from contamination caused by fire protection water supplies. The proposed plan will be subject to formal plan review by the Santa Clara County Fire Department to determine compliance with adopted model codes. The project would increase Town population by 0.5%, which would incrementally increase demand for recreational facilities. The project's potential impact on the demand for recreational facilities is discussed in Section 15, Recreation, below. Based upon population growth estimates in Projections 2009 from the Association of Bay Area Governments (ABAG), the project would add approximately 11 new students to the Los Gatos Union School District and Los Gatos -Saratoga High School District. The Los Gatos Union School District has advised the Town that the development of 47 new residential units under the previous plan would generate approximately 20 new students for the elementary and middle schools in Los Gatos.'7 Under the revised project design of 29 residential units, the project would be expected to generate 12 new students. The District is currently operating at or near capacity at all of the downtown schools and proposed development will result in the need for new classrooms. The District proposes to use funds from an approved bond initiative (Measure E) to fund new facilities that would accommodate some of the new growth in student population. Project students would attend Louise Van Meter Elementary School, Fisher Middle School, and Los Gatos High School. To offset potential additional service costs for enrolling new students from the proposed project, the Los Gatos Union School District and Los Gatos -Saratoga High School District will charge the project applicant impact fees based on the size of new homes (per square foot basis) and by supplemental parcel taxes on the new residential parcels. Payment of impact fees and supplemental taxes would mitigate the project's impacts on school services to a less -than -significant level. Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 15. Recreation - a) Would the project increase the use of existing neighborhood and regional parks or other recreational facilities such that substantial physical deterioration of the facility would occur or be accelerated? X 'Santa Clara County Fire Department, 2010. Development Review Comments. March 9. " Written communication from Richard Whitmore, Superintendent, Los Gatos School District, dated April 26, 2010, commenting on Project File PD-07-145 for 16005 Los Gatos Boulevard. DECEMBER, 2010 45 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD . Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact b) Does the project include recreational facilities or require the construction or expansion of recreational facilities, which might have an adverse physical effect on the environment? X The proposed net addition of 29 single-family residences and six senior apartments would increase local population, and thereby incrementally increase demand for recreational facilities. A common open space area or park is proposed in the residential portion of the project near the western project boundary. The common open space area would be decomposed granite, with an existing redwood tree to be retained along the western project boundary and a seating area to be provided in this area. This common open space is located adjacent to the western project boundary, and existing residential uses are located adjacent to this boundary (see Section 12, Noise, for more discussion of potential noise impacts associated with this park). Private open space associated with the 29 single-family residences would be limited to rear yards and sideyards for all units; Lots 1 through 5 and 15 through 19 would also have small front yards along Blossom Hill Road and Placer Oaks Road, respectively. No private open space is proposed for senior apartments. However, outdoor dining patios for ground floor commercial tenants are proposed adjacent to both commercial buildings where senior apartments would be located. A pedestrian corridor is proposed to connect the residential and commercial components of the project, which would enable senior apartment residents to access the common open space on the western portion of the site. While the provision of a small common open space area is relatively limited for the total number of single-family and apartment units, the project is proposed as a Planned Development, which allows for Town discretion in the evaluation and approval of project elements. The Town has no specific open space standards to determine adequacy of proposed open space for the number of residential units proposed. Nearby recreational facilities include Louise Van Meter Elementary School (one-half mile to the south), Los Gatos High School (one mile to the southwest), and Vasona Park (one-third mile to the west). The project's incremental increase in demand for recreational facilities is considered to be less than significant given the project's proximity to existing recreational facilities, and proposed provision of common open space on the project site. Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 16. Transportation/Traffic - Would the project: a) Conflict with an applicable plan, ordinance or policy establishing measures of effectiveness for the performance of the circulation system, taking into account all modes of transportation including mass transit and non -motorized travel and relevant components of the circulation system, including but not limited to intersections, streets, highways and freeways, pedestrian and bicycle paths, and mass transit? X DECEMBER, 2010 46 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact b) Conflict with an applicable congestion management program, including, but not limited to level of service standards and travel demand measures, or other standards established by the county congestion management agency for designated roads or highways? X c) Result in a change in air traffic patterns, including either an increase in traffic levels or a change in location that results in substantial safety risks? X d) Substantially increase hazards due to a design feature (e.g., sharp curves or dangerous intersections) or incompatible uses (e.g., farm equipment)? X e) Result in inadequate emergency access? X f) Conflict with adopted policies, plans, or programs regarding public transit, bicycle, or pedestrian facilities, or otherwise decrease the performance or safety of such facilities? X The Town's Traffic Impact Policy (Resolution 1991-174) requires preparation of a detailed traffic study for any project with the potential to generate 20 or more additional AM or PM peak hour trips. The Town's contract transportation engineering firm, TJKM Transportation Consultants, has completed an assessment of potential traffic impacts resulting from the proposed project.tsThe traffic impact study is on file at the Town Community Development Department. Trip Generation. Based on the estimated trip generation for proposed uses (29 single-family homes, six senior apartments, and 23,267s.f. of specialty retail), the project would generate approximately 1,647 average daily trips, with 194 AM peak hour trips and 146 PM peak hour trips. According to TJKM, when trip generation from the former auto dealership is considered, the proposed mixed -use project would result in a net increase of 955 daily trips, with 151 AM peak hour trips and 92 PM peak hour trips. Project -related Traffic Impacts. TJKM evaluated the project's impact at the following intersections: Los Gatos Boulevard/ Los Gatos -Almaden Road, Los Gatos Boulevard/Blossom Hill Road, Los Gatos Boulevard/Shannon Road/Roberts Road, Blossom Hill Road/Roberts Road, and Blossom Hill Road/Camellia Terrace. Under Existing Conditions, all study intersections operate acceptably during the AM and PM peak hours, LOS D or better. With 13 approved projects identified in the project area (Existing Plus Background Conditions), these intersections would continue to operate acceptably (LOS D or better) during the AM and PM peak hours, with a negligible increase in delay (less than two seconds of average delay). With the proposed project (Background Plus Project Conditions), all study intersections are expected to continue operating at essentially the same level of service as Existing Plus Background Conditions (LOS D or better) during the AM and PM peak hours. `s TJKM Transportation Consultants, Final Traffic Impact Study for the Proposed Mixed -Use Development at 16005 Los Gatos Boulevard. December 23, 2009, TJKM Transportation Consultants, Addendum for 16005 Los Gatos Boulevard Mixed -Use Traffic Study. April 26, 2010, TJKM Transportation Consultants, Addendum #2 — Revised Site Access Located on Blossom Hill Road for 16005 Los Gatos Boulevard Mixed -Use Project. November 4, 2010. DECEMBER,2010 47 INITIAL STUDY — 16005 LOs GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD The TJKM study also concluded that the there is sufficient roadway capacity on the Los Gatos Boulevard and Blossom Hill Road study segments to accommodate proposed project trips. With addition of traffic generated by approved projects and the proposed project, study segments would operate within acceptable capacity limits (LOS D). Under Existing Conditions, TJKM found that the eastbound left -turn lane on Blossom Hill Road at Los Gatos Boulevard is inadequate for queuing. Addition of traffic generated by approved projects and the proposed project (Background Plus Project Conditions) would significantly increase this Left -turn movement queue. However, implementation of either of the following turning lane improvements will reduce this impact to a less -than -significant level: 16. A second eastbound left -turn lane shall be added on Blossom Hill Road and both left -turn storage lanes shall be extended to 250 feet (per lane) to accommodate future traffic levels. OR The applicant shall contribute to the addition of a second eastbound left -turn lane at the Los Gatos Boulevard/Blossom Hill Road intersection and lengthening both left -turn lanes to 250 feet for its incremental share of impact as determined by the Town Engineer. The proposed project is estimated to generate approximately 10 trips during the highest peak hour (PM peak hour) on Placer Oaks Road (i.e. one car every six minutes). Such an increase should not be noticeable and TJKM concluded that these additional trips are not expected to cause a significant traffic impact. Traffic Safety. The proposed project is expected to have little or no impact on the collision rate (or safety) at study intersections or study road segments. Based on the 2004 Accident Data for California State Highways, the average statewide accident rate is 0.58 accidents per million vehicles for four -legged, suburban signalized intersections and 0.34 accidents per million vehicles for suburban, unsignalized intersections. Based on collision reports obtained from Town staff for the last three years (January 1, 2006 to December 31, 2008) and existing peak hour turning movement counts, the collision rates for all study intersections are below the statewide average collision rates. Therefore, the proposed project is not expected to have a significant impact on future collision rates. Vehicular Access. Currently, the project site is accessed via three driveways on Blossom Hill Road and five driveways on Placer Oaks Road. The all -way access closest to an intersection is located on Blossom Hill Road, approximately 180 feet west of the stop line of the Los Gatos Boulevard/Blossom Hill Road intersection. Additionally, there is a right-in/right-out access for the site on Los Gatos Boulevard, and it is located approximately mid -block between Placer Oaks Road. Project implementation would reduce the total number of driveways from ten to four: two on Placer Oaks Road, one on Los Gatos Boulevard, and one on Blossom Hill Road. Although the proposed all -way access on Blossom Hill Road would be located approximately 260 feet from the curb line of the Los Gatos Boulevard/Blossom Hill Road intersection, this proposed location would meet corner clearance distance requirements and would not interfere with the dual, 250-foot long left -turn lanes required on eastbound Blossom Hill Road under Mitigation Measure #16. Therefore, no significant traffic safety impacts would be associated with the proposed driveway configuration. Pedestrian, Bicycle, and Transit Access. At present, there are sidewalks along both sides of Los Gatos Boulevard and Blossom Hill Road in the project vicinity and these sidewalks would be sufficient to handle project -related pedestrian traffic. In addition, a pedestrian corridor and gate is proposed between project homes and the commercial uses to facilitate the resident's access to commercial uses on the DECEMBER, 2010 48 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD project site. The Los Gatos School District has expressed concerns about the safe travel of both cars and children across the Los Gatos Boulevard/Blossom Hill Road intersection, both before and after school.' Based on the accident history of this intersection described above, this intersection is not considered unsafe for pedestrians. However, the potential increase of up to 20 students crossing this street due to the project is considered a potentially significant safety concern. As a condition of project approval, the Town will require the project to complete improvements at this intersection such as modifying the wheelchair ramps (ADA), pedestrian refuge islands (pork -chop islands), and adding bicycle lane stripes at intersection approaches, which will enhance pedestrian and bicycle safety. In addition, the following measure will be required to further reduce safety concerns to a less -than -significant level: 17. The project will be required to modify their fair share of the Blossom Hill Road/Los Gatos Boulevard intersection and upgrade existing traffic signal to current Town standards including but not limited to ADA ramps, pedestrian islands, signing, striping, vehicular signal heads, pedestrian signals, video detection, safety lighting, as directed by Town Engineer. Currently, there are striped bicycle lanes along Los Gatos Boulevard and Blossom Hill Road in the project vicinity. The project is not expected to generate a significant volume of bicycle traffic, and therefore, no significant impacts on roadway or bike lane capacities are expected. Based on field observations, Santa Clara Valley Transportation Authority (VTA) Bus Line 49 runs along Los Gatos Boulevard in the vicinity of the site. The nearest bus stops for Line 49 are located to the north of the project site on both sides of Los Gatos Boulevard. The project is not expected to have a significant impact on transit ridership levels. The VTA has provided the Town with design recommendations that provide for enhanced pedestrian and bicycle accommodations in the project vicinity. The requested facilities include bicycle parking for the mixed -use condominium and commercial portions of the project. VTA supports bicycling as an important transportation mode and thus recommends inclusion of conveniently located bicycle parking for the project. Bicycle parking facilities can include bicycle lockers for long-term parking and bicycle racks for short-term parking. VTA's Bicycle Technical Guidelines provide guidance for estimating supply, siting and design for bicycle parking facilities.20 Parking. The Town Code would require provision of one parking space for every 300 s.f. of retail commercial space (or 3.3 spaces for every 1,000 s.f.), one and one-half spaces per unit in multiple -unit dwellings, and two spaces for each single-family residential unit. On the eastern commercial portion of the site, 104 parking spaces are proposed for retail commercial uses (4.4 spaces per 1,000 s.f.), which would exceed Town parking requirements. Six spaces are proposed to be provided for senior housing (1 space per unit), which would be less than the required one and one-half spaces per unit. However, the age restrictions (seniors only) would minimize parking demand of proposed apartments and the shared nature. of parking with commercial uses would minimize potential parking shortages. Therefore, no significant impacts from this shortfall of parking spaces are expected. On the western, residential portion of the site, 58 covered parking spaces (two enclosed garage spaces in each unit) and 16 guest spaces would be provided, which would exceed Town parking requirements. Cumulative Impacts. TJKM identifies 10 pending projects that could contribute a total of 293 AM peak hour trips and 557 PM peak hour trips onto the Los Gatos street network. When traffic from pending projects are added (Background Plus Project Plus Pending Conditions), study intersections are expected '9 Written communication from Richard Whitmore, Superintendent, Los Gatos School District, dated April 26, 2010, commenting. on Project File PD-07-145 for 16005 Los Gatos Boulevard. 20 Santa Clara Valley Transportation Authority (VTA), Bicycle Technical Guidelines. Available on the Internet at: www.vta.org/news/vtacmpBikes. Accessed on May 20, 2010. DECEMBER,2010 49 INITIAL STUDY — 16005 LOs GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD to operate acceptably and at essentially the same level of service as under Background Plus Project Conditions, LOS D or better during the AM and PM peak hours. However, southbound left -turn storage at the Los Gatos Boulevard/Blossom Hill Road would not be adequate to accommodate future cumulative traffic increases. Therefore, the proposed project would contribute incrementally to the future need to increase storage capacity for this movement. TJKM recommends that the Town consider increasing southbound left -turn storage capacity as part of future capital improvement projects. This could be accomplished by reconfiguring the median of the southbound approach to accommodate the extension of the existing second left -turn lane to 275 feet. To reduce the project's contribution to this cumulative traffic congestion problem to a less -than -significant level, the following measure containing two options shall be required: 18. The applicant shall modify the Los Gatos Boulevard/Blossom Hill Road intersection to add southbound left -turn storage capacity by increasing the second left -turn lane to 275 feet. OR The applicant shall contribute to increased southbound left -turn storage capacity at the Los Gatos Boulevard/Blossom Hill Road intersection for its incremental share of impact as determined by the Town Engineer. There are six auto dealership sites located on Los Gatos Boulevard and Blossom Hill Road and four of these are currently vacant (former Los Gatos Chevrolet at15600 Los Gatos Boulevard, Swanson Ford at 16005 Los Gatos Boulevard, South Bay Honda at 6213 Los Gatos Boulevard, and Bentley Silicon Valley at 620 Blossom Hill Road). TJKM examined two future cumulative traffic scenarios that could result if these currently vacant auto dealerships (other than the proposed project) were to either: (1) become re- occupied with the previously -approved auto dealership use; or (2) redevelop into other uses (assumptions developed by Town staff). Under the first scenario, re -occupation of the three vacant auto dealerships could add 111 AM peak hour trips and 189 PM peak hour trips. With such traffic increases, study intersections would operate acceptably and at essentially the same level of service as under Background Plus Project Plus Pending Conditions, LOS D or better during the AM and PM peak hours. Under the second scenario, redevelopment of the three vacant auto dealerships could add 1,383 AM peak hour trips and 584 PM peak hour trips. With such traffic increases, study intersections would operate at essentially the same level of service as under Background Plus Project Plus Pending Conditions (LOS D or better during the AM and PM peak hours) with one exception. The Los Gatos Boulevard/Blossom Hill Road intersection would operate unacceptably at LOS E during the AM peak hour, a potentially significant cumulative impact. However, this intersection would operate acceptably (LOS D during the AM peak hour) with addition of a second eastbound left -turn lane. This improvement is already identified above and will be required as part of the proposed project. Therefore, this cumulative impact would not be cumulatively considerable with implementation of the above project -related Mitigation Measure #16. Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 17. Utilities and Service Systems — Would the project: a) Exceed wastewater treatment requirements of the applicable Regional Water Quality Control Board? X DECEMBER, 2010 50 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact b) Require or result in the construction of new water or wastewater treatment facilities or expansion of existing facilities, the construction of which could cause significant environmental effects? X c) Require or result in the construction of new storm water drainage facilities or expansion of existing facilities, the construction of which could cause significant environmental effects? X d) Have sufficient water supplies available to serve the project from existing entitlements and resources, or are new or expanded entitlements needed? X e) Result in a determination by the wastewater treatment provider, which serves or may serve the project that it has adequate capacity to serve the projects projected demand in addition to the providers existing commitments? X f) Be served by a landfill with sufficient permitted capacity to accommodate the projects solid waste disposal needs? X g) Comply with federal, state, and local statutes and regulations related to solid waste? X Utilities are currently provided to the project site. The proposed building would be required to connect to the existing water and sewer lines located on or adjacent to the site. Project development would also include construction of storm drainage facilities (see Section 9, Hydrology and Water Quality). The Fire Department will require provision of an approved, automatic fire sprinkler system in the proposed building. Other utilities (electrical, gas, telephone, cable TV facilities) will be upgraded as necessary. Sewer service to the proposed development is available from a six-inch sewer line in Blossom Hill Road and another six-inch sewer line in Placer Oaks. Due to the size of the development, the District will require the developer to conduct a flow study determining the project's impact to these two lines. Based on the results of this study, the developer may be required to replace the existing sewer line(s) in order to handle the increased sewage flow from the development.21 Required upgrades would reduce potential impacts on utilities to less than significant. 21 Email communication dated April 23, 2010 from Jonathan Lee, Senior Civil Engineer, West. Valley Sanitation District, to Heather Bradley regarding Project File #PD-07-145, 16005 Los Gatos Boulevard (Swanson Ford Site). DECEMBER, 2010 51 INITIAL STUDY — 16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD Issues (and Supporting Information Sources) Potentially Significant Impact Potentially Significant Impact Unless Mitigation Incorporated Less Than Significant Impact No Impact 18. Mandatory Findings of Significance - a) Does the project have the potential to degrade the quality of the environment, substantially reduce the habitat of a fish or wildlife species, cause a fish or wildlife population to drop below self-sustaining levels, threaten to eliminate a plant or animal community, reduce the number or restrict the range of a rare or endangered plant or animal or eliminate important examples of the major periods of California history or prehistory? X b) Does the project have impacts that are individually limited, but cumulatively considerable? ("Cumulatively considerable" means that the incremental effects of a project are considerable when viewed in connection with the effects of past projects, the effects of other current projects, and the effects of probable future projects)? X c) Does the project have environmental effects which will cause substantial adverse effects on human beings, either directly or indirectly? X DECEMBER, 2010 52 INITIAL STUDY -16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD ATTACHMENT 1 PROPOSED SITE PLAN 1 9 r6m1514*a I . kg a Z cc 0 ca < CC0 CO 0)0 aO) ill Q d V O 0. tlr Cn A INITIAL STUDY -16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD ATTACHMENT 2 URBEMIS MODEL RUN Page: 1 4f22/2010 12:16:20 PM Urbemis 2007 Version 0.2.4 Combined Summer Emissions Reports (Pounds/Day) Flle Name: CPDocuments and SaOings\Sara Garrick\Application Data\Urbemis\Version9a\Projacts\Los Gatos and Blosson Hill.Road,urb924 Project Nome: Blossom HIA Road at Los Gatos Project Location, Bay Area Alr District On -Road Vehicle Emissions Based on: Version : Ernlac2007 V2.3 Nov 1 2006 011•Road Vehicle Emissions Based on: OFFROAD2007 Page: 2 4f22R01012:16120 PM Summary Report: CONSTRUCTION EMISSION ESTIMATES 2010 TOTALS (byday unm0gated) 2010 TOTALS (bsrday Mtl5ato4) 2011 TOTALS (bsiday unnitl8ated) 2011 TOTALS 16dday lM6patod) AREA SOURCE EMISSION ESTIMATES Bata lion ' co 602 PM topug PM10Fdhaug MI PM2.5Dua1 Py2.0 P.M2.5 c02 FzDaual 4.44 3676 19.71 0.01 43.02 1,81 44.64 e.09 1.67 10,66 3,962.10 4.44 32.02 19.71 0.01 4.85 0.56 5,21 0.98 0.51 1.49 3582.10 28.67 38.02 35.45 0.01 0.07 2.84 2.91 0.02 2.61 2.63 4,647.55 26.50 31.90 35.45. 0.01 0.07 0.49 0.55 0.02 0.45 0.47 4,647.55 TOTALS (balday, unmlegata ) OPERATIONAL (VEHICLE) EMISSION ESTIMATES TOTALS (brrday, unmPogatod) Bag _ N9a 00 Sot 2fSI0 EM2.6 Gait 4.80 0.97 7.62 0.00 0.02 0.02 1,121.95 Bata Nax 00 602 P.SUG 2bf2,5 Got 18,28 13.03 131.89 0.13 21.92 4,18 12,346.70 SUM OF AREA SOURCE AND OPERATIONAL EMISSION ESTIMATES Bab ttaa GO 502 MUG EMU Gat TOTALS(barday, unreelgabd) 14.80 14.00 139.51 0.13 21.94 4.20 13,468.85 Construction 1511NUgated Walt Report: CONSTRUCTION EMISSION ESTIMATES Suemor Pounds Par Day. Unmitigated Boa rtoa GO 602 pima out p60g Egytyt MI6 5121.11141 PM) E P.E92.S 002 Page:3 4/22/201012:16:20 PM , 1194810e 1111/2010.12/31/2010 4,4 36.7a 16.21 011 90.02 1.01 99.04 0,80 102 10.00 0087.10 AOWo Days: 45 Mass 0re4003 111012010. 4.44 38.78 19.71 0.01 43,02 1.01 44.04 0.99 1.67 10.68 3.002.10 12/3I2010 Mass Otodng Dun 0.00 0.00 0,00 0.00 4297 0.00 42,97 8.97 0.00 0.07 0.00 Masa Grading 00 Road 010681 3.02 27.50 15.08 0.00 000 1.48 1.48 0,00 1.30 1.36 2.614,14 Most Oradng On Road 014501 0.60 9.09 290 0.01 0.05 0.33 0.30 0.01 0.31 0.32 1295,10 Mass Grading Warhol' Taps 0.06 0.10 1.74 0.00 0.01 0.00 0.01 0,00 0.00 0.0, 162.87 Time Mao 142011.5/312011 4.31 20.67 23.94 0.01 0.00 1.50 1.50 0.02 1.38 1.40 • 3,135,60 Addeo Days: 107 Bdldyg 0IATl/2011.12l3I/2011 4,31 20.67 23.94 0.01 0.00 1.50 1,58 0.02 1.38 1.40 3,135.50 Bulldog 09 /load 09oa41 3.01 19.02 33.12 0.00 000 1.44 1,44 0.00 1.32 1.32 1.040.63 Buad'ng VondorTrips 0,00 1.10 0.67 0.00 0.01 0.04 0.05 0.00 0,04 0.04 238,83 Bu0dl g Wotkar Trips 0.32 0.55 9.95 0.01 0,05 0.02 0,07 0.02 002 0.04 94822 Page: 4 422/201012316:20 PM 11m8Sara 011/2011.12/30/2011 20.02 88.02 06.90 201 0.92 204 201 0.02 261 2.21 4.047,55 AttNo Ooys:153 Asphalt 080112011.12/312011 257 16.33 11,24 0,00 0.01 1.33 1.34 0.00 1.23 1,23 1,488,13 Vos 000'Oas 0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Paving 00 Road 09301 248 15.15 9,07 0.00 0.00 1.33. 133 0.00 1.22 1,22 1,272.04 Paving On Road Obsol 0.00 0,06 0.02 0.00 0.00 0.00 0.00 0,00 0.03 0.00 10,14 Payton Worker Taps 0.07 0.12 214 0.00 0.01 0.01 0.02 060 0.00 0.01 203.95 Buading 011012011-12/31/2011 4,31 20.07 23.94 0.01 0.00 1.50 1.58 0.02 1.30 1,40 3,135.50 29/1900500 /load 240001 3.01 19.02. 13.12 0.00 0.00 1.44 1.44 0.00 1,32 1.32 1,948.88 Bu009g Vendor Tr¢ts , 0,00 1.10 0.87 0.00 0.01 0.04 0.05 0.00 0.04 0.04 238.03 Bulldog Workor Tips 0.32 0,55 8.95 0.01 0.05 0.02 0.07 0.02 ' 0.02 0.04 94822 Coalig 0&012011.12/31f2011 21,79- 0.02 027 0.00 0.00 0.00 0.00 0.00 0.00 0.00 25.92 Archllocwral Cooling 21.79 0.00 0.00 0.00 0.00 600 0.00 0.00 0.00 0.00 0.00 Coalk6 Worker Tdp3 0.01 0.02 027 0,00 Om 0,00 0.00 0,00 0.00 0,00 25.02 ehas624,2205d252 Phase: Mass Otadlog 11/12010. 12412010.0a10ub Few 5110 OraWg ()ascription Total Actaa ObNrba4: 5.18 Madmum Oa0yAcroage 0144ttbod: 1.3 Fug9Wo Oust Laval of Data:Love Oru0a COVFI0 254 adc yards410y1 Off Oa CUVFia: O ado yards/day On Rood Tad1 Tr0vo1 (VMT): 321.68 064load P.gtdpnsnb 16961ers (I74 hp) oporathsg at a 0.61 load lacta 090 halts par day 1 Rubb0r Nod 0orata(357 hp) oporatbg al a 0.59 Iced !actor lot 0 how par day 2 Skid Stoat London (44 hp) operation at a OM bad !attar for 0 hours pot day 1 Tr04110t0409d01A35446w0a (10014) oPo Woo a1 a 0.85load factor lot 7 touts per day Paget 4220201012:18:20 PM 1 Water Trtlda (189 hp) operating at a 0.5 bad factor for 8 hours par day Phase: Paving WI /2011 • 12/31/2011 •0alaua Paving 0ascription Acne to bo Paved: l.3 OffMRord Egulpman5 4 CameM and Mortar Mama (10 hp) operating at o 0.58 bad factor for 8 hours par day 1 Pavers (100 hp) apomt0g al a 0.02 bad (actor tot 7 toms pm day f Po ing EQ44m0M (104.hp) 0pmatYq al a 0.53 load factor lot 81ours par day 1 Rollin (95 hp) oporattq M a 0.58 bed lacier for 7 hours per day 1 Tra1Wr1M1aadorLHocbbea (108 hp) 0panting at a 0.55 bad factor for 7 hours pm day Phase: BWb4g CM3lmgbn 1/12011 •12/312011 • Defautr Bulking CoMmbion Descriptlon 0841aad Equipment 1 Cranes (399 W) operating at a 0.43 bad factor fm 6 hours par day 2 Parallta (I45Ip) opomt4g at a 0.3 bad factor br 8 tours par day 1 gmamtor Seta (49 hp) operating at a 0.74 load factor for 8 hours per day 2 Tra0nmAaedemr0atldaoa (108 hp) operating at a 0.55 bad lector lore hours par day 3 Walden (45 hp) 0parsteg at a 0.45 bad factor for 8 holm par day Phase; Ar0Nto0Wml Coating 8/12011 • 12/31/2011 • Dalaul ArcNtacturol Coating Desmiptlan Rub: Ra11doM4d k0odor Coatings begins 1/12005 ends 12/31/2043 spod00s a VOC o1250 Rub: Resldsnl1N Esador Coa0ngs begins 1/12005 ends 121312040 sp0dtios a VOC of 250 Rub: Nar0e0Na0W interior Coalinga begins 1112005 ends 12/312040190000s a VOC at 250 Rub: Nonresidential Emados Coatb0a begins 1/12005 ands 12/312040 specifies a VOC o1250 Corntludbn 8688atad Detail Rapott CONSTRUCTION EM15S10N ESTIMATES Summer Pounds Par Day, Mitgatad 002 210E CQ S02 pule noq P21IOFtfmr6 ELM 5152.1.0851 EM2.5.2shaul EM2.5 CO2 Page:6 4/22/201012;1810 PM Time Shoo 11112010.12/31/2010 999 32.82 1221. 9.51 9.81 0.50 521 0.80 0.51 1.02 2.082.10 Actho Oay4: 45 Mass Oredsg 11/01/2010• 4.44 32.62 19.71 0.01 4.65 0.56 5.21 0.98 0.51 1.49 3,682.10 12/31/2010 Mass Orading Dust 0.00 0.00 0.00 0.00 4.60 0.00 4.60 0.98 0.00 0.90 0.00 Mass Grading 0ll Road Nasal 3.82 23.43 15.03 0.00 0.00 0.22 0.22 0.00 0.20 0,20 2,514.14 Moss Wading On Road Diesel 0.58 8.09 2.90 0.01 0.05 0.33 0.38 0.01 0,31 0.32 1,295.10 Mate 0mmng Worker Tdps 0.08 0.10 1.74 0.00 0.01 0.00 0.01 0.00 0.00 0.0, 152.87 TIme Slice 1r72011.0/312011 4.31 18.82 23.84 0,01 0.08 0.28 0.34 0.02 0.26 0.28 3,135.50 Acid, Days; 107 600641p 010112011.12/31/2011 4.31 18.82 23.94 0.01 0.06 0.28 0.34 0.02 0.26 0.28 3,135.50 Wilding 00 Rood Mosel 3.91 17.17 13.12 0.00 0.00 0.22 0.22 0.00 0.20 0,20 1,848.68 Building Vandoc Trips 0.08 1,10 0.87 0.00 0.01 0.04 0.05 ' 0.00 0.04 0.04 238.63 Bulking Wmkar Trips 0.32 0.65 9.95 0.01 0,05 0.02 0.07 0.02 0.02 0.04 948.22 Pago: 7 4122/2010 12:16:20 PM Tinto Silo o/I2011.12/302011 26.00 aL22 26.46 0.01 092 092 0,65 0.02 04.5 RAL 4.647,56 Ac1No Cloys: 163 Aspho508/012011. 12/312011 2.67 13,00 11,21 0.00 0.01 0.21 0.22 0.00 0.19 0,10 1,180.13 P866000003 0,02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.03 0.00 PevIng00 Rood Moo! 2.48 12.00 9.07 0.00 0.00 0.20 0.20 0.00 0.18 0.10 1,272,04 Paving On Rood (Mosel 0.00 0.06 0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10,14 Paving Worker Trips 0.07 0.12 2.14 0.00 0.01 0.01 0.02 0.00 0.00 0.01 203.95 &663001/012011.12/312011 4.31 10.82 23.94 0.01 0,05 0.28 0.34 0.02 026 0.20 3,135.60 Biddxg 0(0 Road Mosel 3.91 17.17 13.12 0.00 0.00 0.22 0.22 0.00 0.20 0.20 1,048.60 Budd:no VerNor Trips 0.00 1,10 0.87 0.00 0.01 0.04 0.05 0.00 0.04 0.04 238.53 B1er&g Worker Trips 0.32 0.55 9.95 0.01 0.05 0.02 0.07 0,02 0.02 0.04 948.22 Coating 05012olt•twatnot 1 19.61 0.02 0.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 25.02 Ardtkemaat Coating 19.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00 0.00 0.00 Coating Worker Trips 0,01 0.02 0.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 25,92 fmntnonion Roletod MIOaslbn Measures Tho following magallon moaaures apply to Phew; Moss Orod(Og 11/12010. 12/312010. 001auk Fires Slto Grading Description For Sok Slabbing Measures, Ow Apply sob stahitaare to Inactive areas minga0on roducos omissions by: PM10: 04% PM25: 84% For Soli Stabbing Moasuris, Ito Replace ground cover In dlaturbad Bran quickly mkgauon reduaos erds51ans by: PM10: 6% PM25: 5% For Soil Stabbing Measures, the Water exposed summates 2x daily watering mkg60en reduces emeiskna by: PM10: 55% PM25: 55% For Urpavod Roads Measures, the Reduce speed on unpaved toads to loss than 15 mph rti0gs0on reduces emissions by: P010:44%PM25:44% For Unpaved Roads Moowras, rho Manage haul mad runt 2x dairy watering mitigation reduces omisstn by: PM10; 55% PM25: 55% Pago: 8 4/22/2010 12:18:20 PM For °radon, the 0bs01 Pa/Wu:af Flier (DPP) 1st TMir mitigation redu0oa omissions by: PMIO:65%P1A25:85% For 0radon, 610 Olo1ol Odda6mt Catays( 15%m8ga0on rodocos on/ssbns by: NOX:16% For Rubber Tkod Dozers, the D1ese1 Particulate Flier (OPF) 10 Tlor m1Ugsaon reduces emissions by: PM10: 85%PM25:85% For Rubber Mod 0000rs, 610 Diesel Oxidation Catalyst 15%mitlg0lon radoone omissions by; NOX: 15% For Tre0Oa2Aa0darslBaddwos, thu Nasal Particulate FlI(Or (OPF) Isl Tier megaton raducea emissions by: PM10; 8500 PM26: 65% For TndorsILOadorNBad610os, the Diesel Oxldellon Oiteyst 15% mitigation reduces omissions by: NOX: 16% For Water Trucks, tho Oleael Pamculoto Filter (OPF) 1s17Mr nil gelbn reduces eteerom by: PM10: 85% P1425: 85% For Water Tmcks, th0 Cassel Odda6on Catalyst 15% mitigation ruducos am(sebna by: NOX; 16% For Skid Moor toodnrs, the Masai Penculato Fitter (OPF) 1M Tier mitigator: roduoos emissions by: P0010: 86% PM25: 85% For Sidd Stier Loaders. 61u Dkael 0dda60d Catalyst 15% midgetlon redacos emissions by: NOX: 15% 1ho lonevdrg mitigation nnasurm apply to Phut: Paving 6112011 • 12/31/2011 • Deleon Paving Destr(Xbn. Poi Cement and Mortar Mixers, tin Nasal Particulate Fitter (OFF) 1st Tier rrstigation educes anesslins by: PM10: 85% P1,125: 05% For Camera end Mortar Mbers, 61e Ousel Oxidation Catalyst 15% mitigation roduaea erNssi0 3 by: NOX: 15% For Povars, 610 Olosel Perlkulata Akor (OPF) int Tlor mitigation reduces omissions by: PM10: 85% P1.426: 85% For Peyote, tin Olasol O dd: Pon Catalyst 15%mago0on rod000a emissions by: NOX: 16% For Rolla%6,i 01o101 Pa/Umtata Filter (DPF) 1st nor raft:Pion roduces emissions by: Pape: 9 4/22/201012116:20 PM PMI0: 85% PM25: 65% For Ro2Ns, the Diesel Cddetlon Catalyst 16%mitigation rodcos emission by: N0X:15% FO,Trectorwtoodoro/aoddnee, the Diesel Partl0mite Attar (OPF)1st Tier mitigation roduoas omissions by: PM10: 65% PM25: 85% For TradOnt ondo000ntld1oes, Ilia Mewl Oxidation Catalyst 16% mitigation reduces on+lssbns by: NOX:16% For Paving Equipment, the Diesel Partlwtata Filler (DPF) 1st Tier mitigation reduces omissions by: P210: 66%P2020: 85% For Paving Eg4unerd, the Diesel Oddafbn Catalyst 15% mitigation ,educes emissions by: NOX: 16% Th0 foaming mitigation measures espy to Phase: BWldeg Construction 1/1/2011 - 12/3 2011 • Derma IM01g Construction Oescripdon Far Cranes, tine Mosel Particulate Filer (DPF) 1 at liar mitigation mdoMO emissions by: PM10:86%PM25:85% For Cranes. tlt9 010101 Oxidation Catalyst 15% mitigation radn0es emissions by: NOX: 15% For Foddns, the Diesel Partadato Rtior(DPF) 1st Tier mitigation reduces emissions by: PM10:65% PM25: SS% For ForkVts, the Valet Oddalton Catalyst 15% mitigation reduces emissions by: NOX: 15% For TmctorM oodo2/Bod hoe., the Dlasal Particulate Filler (OFF) 1st Tier Mdgetion reduces emissions by: PM10:65%PM25:85% For 0onomtor 8020, the Diesel Particulate Filer (OFF) 1st Rot mitigation reduces emissions by: PM10:65% PM25:85% For Generator Sots, the Mewl Oddelkin Catalyst 16%mitigation roduooe OMISSION by: NO* 16% Far Welders, Ilc Oie0al Particulate Filter (DPF) 1st Tier mitigation roduco$ emissions by: PMIO:85% PM26:85% For Welders, Oto 0ie1e1 Oxidation Catalyst 15% mitigation,,d40a$ emissions by: NOX: 16% Pape:10 4/22/201012:16/0 PM The kraohirg mitigation mee0la0.e apply Io Pitaoa: Anohlto lust Coating 8/12011-12012011 • Dolma Arnadu,IWOI0oating Description For Residential Architectural Cooling Measures, One Rasidomlal E0odor: Usti Low VOC Coatings mitigation 'odour's emissions by: R00:10% For Residential Architectural Coating M00sum0, tic Rosldantial interior: Uso low VOC Coatings mitigation radices oml=d0 s by: ROO: 10% Foe Nonresidential ArWtoctural Coating Me0sums, Oq NOw00460n0at Emtirior: Use tow UDC Coatings mitigation reduces omissions by: R00:10% For Nomesidonlial Architectural Coating Measures, llc Nomosidontlel imedor: Uso Low VOC Coalinga mitigation reduces omissions by. R00:10% Area Source Umnyigetlsd Deta5 Roporb AREA SOURCE EMISSION ESTOAATES Summar Pounds Per Oay, Unmitigated Sous 000 04a G0 542 PAW EMU G02 N0N10l Gas 0.07 0.88 0.44 0.00 0.00 0,00 1.109.44 Hearth • No Summer Emissions Lardlcopo 0.80 0.09 7.18 0.00 0.02 0.02 1251 Consumer Products 2.79 Arcl3eclural Coatings 0.91 TOTALS(WMay, unmitigatod) 4.60 097 7.62 0.00 0.02 202 1,121.55 Arno Source ).herg.2 to neleurts Page: 11 4A227201012316:20 PM Oporosoml Unmitigated Dotall Depart OPERATIONAL 065505I0N ESTIMATES Summar Pounds Par Day, Urvnkl001od ji4u1ffi R00 PDX co 602 PMIO PM25 CO2 Singlo foray housing 3.30 3.01 40,93 0.04 8.81 1.20 0,74814 Ratlromentcornmuriy 033 0.30 3.10 000 0.51 0.10 280.01 High 0 m0var.(tlid0Mm) lost. 340 4,87 40.63 0.05 0.17 1.68 4,680.97 S15sma0 2,00 • 3.05 30,27 0.04 0.03 1.20 3,721,44 TOTALS(031May. unmitigated) 10.28 13.03 131.80 0.13 21.02 ' 4,10 12,340.70 0poradaral 60ttlrgss Doss not include oormaaan far posiby trips Does not !Wilda doublo counbna adjustment iar hdornol hips Analysis Yam: 2011 Tampoloturo (P)I 05 Soasom Summar Emiam Waled : Em14a2007 72.3 Nov 12006 4ammary ell and Ulu Land Usa typo A4voogo Trip Fiala Urrl Typo No. UNts Total Trips Total VMT Single lan450 !lading 2.98 0157 dwolloo units 47.00 449.79 3,845.67 Ra0rame4commur:y 1A2 347 dnoling units 10.03 34.70 290.87 Mgh turnover(sR-0oso) mat 12139 1000 sq It 6.26 037,09 4,767,76 SWp nub' 4432 1000546 11.70 52209 3,659.01 1,644.57 12,750,03 Pago: 12 4/22/201012116:20 PM Vehicle Pint MIS Volado Typo Parson Typo Non•Calayst Catalyst Dlosol U1144 Mb 63.8 0.9 00,7 0.4 Ugtd Track<31601bs 12.0 1.6 05,3 3,1 Wit Tnsd 3761.676010s 19.0 0.5 09.5 0.0 Mod Truck 5751.8500W 0.6 0.0 100.0 0.0 Utmliaavy Truk 8601.10,000 Ds 0.0 0.0 77.0 22.2 Ut441aavy Truck 10.001.14,000 Ds 0.8 0.0 50.0 60.0 Med4laaW Truck 14001.33,00010s 1.0 0.0 20.0 80.0 H0r4y1aavyTnxk33,0e1.80,0001bs a.4 0.0 0.0 100.0 Other Bus 0.1 0.0 0.0 100.0 Urban Goa 0.1 0.0 0.0 100.0 Motorcycle 3.2 02.5 37.6 0,0 School Bus 0,1 0,0 0.0 100.0 Motet Ramo 0.0 0.0 63.3 16,7 Trim' CnrvlaMn1 Roskloetlol Coronado! Homo.Wotk Homo•Shop Homo•OOwr Commulo Non•Wark Cottony Uman Trip tanglh (m000) 10.0 7,3 7.5 9,5 7.4 7.4 Rural Tdp Langih(mlloa) 10.0 7.1 7,9 14,7 6,0 0.0 Trip apoods (rrph) 35.0 35.0 35.0 35.0 35.0 35.0 %ol Trips-RosIdon0al 32.9 10.0 49.1 Page:13 4122/20101240:20 PM T,vICd % Residential Commerdal HamaWodc Homo -Shop HomaOthor Connate NarWork CuRarwr 1 %ol Trips - Consnerdd (by tend use) 100h wmovor(st.dorm) rota. 5.0 2.5 026 Strip moo 2.0 1.0 07.0 t chase, m Waits Page:1 4/221201012:20:21 PM Murals 2007 Version 9.2.4 Combined Annual Emissions Reports (Tons/Year) Filo Name: CADocuments and Solings\S6ra GonicV ppllcnllon Data\UlbomisWeroton9o\Projectsllos Gatos and Blosson Hill Road,urb924 Project Name: Blossom Hill Road at Los Gatos Project Location: Bay Area Alr District On•Road Vehicle Emissions Based an: Version : Em1ac2007 V2.2 Nov 1 2000 OlhRood Vehicle Emissions Based on: OPFROAD2007 Page:2 4/22/201012:20:21 PM Summary Myatt CONSTRUCTION EMISSION ESTIMATES 00/2 d0x 00 802 215aDusiPMl0 Fdwrrs1 P1110 PM25 noel PM)5 Pu25 '002 ELb011}1 2010TOTALS Sonslyaarunmaigatad) 0.10 0.03 0.44 0.00 0.97 0.04 1,01 0.20 0.04 024 09.15 2010 TOTALS (Ionayoot mslgalod) 0.10 0,73 0.44 0.00 0.10 0.01 0.12 0.02 0,01. 0.03 09.15 Forooa 9e:Walml 0.00 11.25 (W0 0.00 09.19 69.29 00.30 89.13 6920 00.80 0.00 2011 TOTALS (tonsamar unNtlsorad) 242 3.80 3.00 0.00- 0.01 0.30 0.31 0.00 0.27 022 52329 2011 TOTALS (I0 nlyoar adlgarad) 220 3.45 3.99 0.00 0.01 0.05 0.08 0,00 0.05 0.05 52320 Peroont Reduction 6.07 10,72 0.00 0.00 0.00 0242 80,25 0.00 0254 8150 0.00 AREA SOURCE EMISSION ESTIMATES TOTALS (l4Mlyesr, urunhloolod) OPERATIONAL (VEHICLE) EMISSION ESTIMATES TOTALS (toneyaat, Lnm810110d) B01 H0x Ir0 502 EM.10 £MZ5 002 1,09 0,10 1.04 0,00 0.10 0.18 • 233,70 E00 NQx CO S02 P1110 PM2:5 CO2 159 2.78 24.69 0.03 4.00 0.76 2,161.74 SUM OF AREA SOURCE AND OPERATIONAL EMISSION ESTIMATES BM NOx C 3 E122 E6110 EM2.5 G02 TOTALS(I5Wy0or, Im:AIWd) 3.00 2.95 20.63 0.03 4,19 0.94 226552 Comauafon UtmM9atad Detail Rap= CONSTRUCTION EMISSION ESTIMATES Annual Tom Par Year, Umi019alod Page:3 4422010 12:20:21 PM HOG 0.00 GO 202 E6S1IIR19 2MI21ihs81 E6110 P1425 Dust 0M2 a r,ssos emu G02 2010 0.10 0.83 0.44 0.00 0.97 0.04 1.01 020 0.04 0.24 69.15 Mass CrodMp 111012010• 0.10 0.83 0.44 0,00 0.97 0.04 1.01 0.20 0.04 0.24 89.15 12/31/2010 Man Gracing Dust 0.00 0.00 0.00 0.00 0.97 0.00 0.97 0.20 0.00 0.20 0.00 Mass Gracing 011 Road (Nasal 0.09 0.62 0.34 0.00 0.00 0.03 0.03 0.00 0.03 0.03 58.5/ Masa arerarg On Road Diesel 0.01 0.20 0.07 0.00 0,00 0.01 0.01 0.00 0.01 0.01 29,14 Mass Grading Waller Trips 0.00 0.00 0.04 0.00 0,00 0.00 0.00 0.00 0,00 0.00 3,44 2011 2.42 3.66 3.99 0.00 0.01 0,30 0.31 0.00 0.27 0.28 523.29 MAIM 01/01 2011• 12/31/201 t 0.56 2.69 3.11 0.00 0.01 0.20 0.20 0.00 0.18 0.18 407.62 Bulking 09 Road Obsel 0.51 2.47 1.71 0A0 0.00 0.19 0.19 0.00 0.17 0.17 253.33 Bulking Van don Taps 0.01 0.14 0.11 0.00 0.00 0.01 0.01 0.00 0.00 0.01 31.02 &Airing Workor Trps 0.04 0.07 1.29 0.00 0.01 0.00 0.01 0.00 0.00 0.00 12327 Alphas 00012011.12,3120i i 0.20 1.17 0,86 0.00 0.00 0.10 0,10 0.00 0.09 0.09 113,60 P0555900-004 0.00 0.00 0.00 0.00 0.00 0,60 0.00 0.00 0,00 0.00 0.00 Paving 00 Road Distal 0.19 1.18 0.69 0.00 0.00 0,10 0,10 0.00 0.09 0.09 97.31 Pavkg On Road Diesel 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.70 Paving Worker Trips 0.01 0,01 0.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 15.60 Casting 00012011.12/312011 1.87 0,03 0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1,98 Atchaoc7urol Coating 1.87 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00 Coaling Worker Trips 0.00 0.00 0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.98 Phase AUummkvn Phew: Moss Gracing I II1/2010. 12/312010 •0aloe Flno Sho Grading ()ascription Toth Agree Dtsturbod: 5.10 Page:4 422/201012:2021 PM Magnum 0&1. AaooBa Dlsarbod: 1.3 Fugitive Dust Leval of Dolan: Low 0ns0o CuVFl1 254 curio yards/day; 00stta Cu5P16: 0 cubic yards/day On Road Truck Trove! (VW): 321.68 04.Rood Equfpmont 1 Graders (174 p) opamtkg as a 0.e1 bad factor to 6 Fora per doy 1 Rubbar Tired Ducey (357 hp) 0puratkg at o 0.59 bad factor for 8 hours per day 2 Skld Storer Loaders (44 hp) operating at a 0.55 bad factor for 6 hours per day 1 Tradorelloaderaladenoe (108 p) oporatkg at a 0.551oad facto for 71ours par day 1 Water Trucks (189 hp) operating at a 0,5 bad factor for 0 fours per day Phase:Paving 012011 • 127312011 • Doloue Paving Description Asa to be Paved: 1.3 00•Road Equprrkhb 4 Commit and Mo9O1 M0oots (10 hp) oparst n at a 0.66 bad facto. for 8 hours par day 1 PavOrs (100 hp) upending et o 0.02 bad factor for 7 hours per doy 1 Paving Egtripnlaa (104 hp) operatkrp 01 a 0.53 bad factor for 8 tours poi day 1 Rollers (95 hp) oparelk9 a1 a 0.66 bad lector for 7 hours per day 1 Trecwa0nedars/2arifoes (I081p) oparainp 41 a 0.65 Mad !actor for 7 hags per day Phase: 0r2karg Construction 1/12011 • 12/312011-Oofau9 Bulking Construction DOsaptlon 0041oad Equipment: 1 Cranes (099 p) operating m a 0.43 bad factor tar 6 tours par day 2 ForMM (145 p) eparstig or a 0.3 bad lector for 8 houn pot day 1 Generator Sots (49 p) operating at a 0.74 bad factor for 0 hours par day 2 Tr9cbr940adati9adaods (108 p) operating at a 0.5510ad !ado. for 8 hours per day 3 Welders (45 p) 0peradr0 at a 0.451ood factor for 0 hours per day Phase: Arddtothwal Coating B112a11 • 127312011 • Waite Arctvtocturat Combo 00984paon Rule: Rea:Sa dal Works Coatlrgs bopku 1/12005 WAS 12/312040 spedtos a VOC a 250 Pag0:5 4/22/2010 12:20:21 PM Rub: Residamial Exada CoOUnge bopins 1/1/2005 ends 12731/2040 spod6os 0 VOC 01250 Ruh: NoruoaIdandel Interior Coadngs begins 1/1/2005 ends 12/312640 spodAas a VOC o1250 Rub: Nonreskaraal Fanorhr Coa9ngs bog0u 1/1/2005 ands 12/31/9040 spoolllns a VOC o1260 Conswalbn 69dgelod D4lall Rapo0l CONSTRUCTION EMISSION ESTIMATES Annual Tons Par Vow, Mttlgolod 6R6 (00X 00 502 pm1oDud 111315940 1 EMU/ PM2.5Dull pinsFsheel EMU 002 2010 0.10 0.73 0.44 0,00 0.10 0.01 0.12 0.02 0.01 0,03 09.16 Mass Gredrg 11/012019 0.10 0.73 0.44 0.00 0.10 0,01 0.12 0.02 0.01 0.03 09,15 12/31/2010 Mass Grading Dust 0.00 0.00 0.00 0.00 0.10 0.00 0.10 0.02 0.00 0,02 0.00 Moss Greding 00 Road Diesel 0.09 0.63 0.34 0.00 0.00 0.00 0.00 0.00 0.00 0.00 68.57 Mass Grr0ng On Rood Mosel 0.01 0.20 0,07 0.00 0.00 0.01 0,01 0.00 0.01 0,01 29.14 Mess 01e0ng Worker Trips 0.00 0.00 0.04 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3.44 Pag9: 6 4/22/201012120 21 PM 2011 2.20 3,45 3.09 0.00 0.01 0.05 0.00 0.00 0,05 0.06 62320 Buidkq 01/012011.12/312011 0.68 2.45 3.11 0.00 0,01 0.04 0.04 0.00 • 0.03 0.00 407.82 BulkSg O6 Road (Soul 0.51 223 1.71 0.00 0.00 0.03 0.03 0.00 0.03 0.03 263.33 &Wing Vendor Taps 0.01 0.14 0.11 0.00 0.00 0.01 0.01 0.00 0.00 0.01 31.02 Bu6Gg Wafter Trips 0.04 0.07 1.29 0.00 0.01 0.00 0.01 0.00 0.00 0.00 12327 Aa9b0106012011.127312011 0.20 1.00 0.86 0.00 0.00 0.02 0.02 0.00 0.01 0.01 113.80 Pavng00-0es 0,00 0.0g 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 moo Paving Off Rood Mead 0.19 0.00 0.69 0.00 0.00 0.02 0.02 0.00 0.01 0,01 07.31 Paving On Road Dhsel 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.70 Paving Wakes Trips 0.01 0.01 0.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 16.60 Cooing 06012011.12/31NMI 1.60 0.00 0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.98 MWtalurd Coning 1.60 0,00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Cootkg Worker Trips 0,00 0.00 0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.98 C_ ,boot/n Ralead Meaatbn Mnos/ooa Tbo tol40Mrg m6gotlon na951.004 *pry to P1as0: Mass Otnablg 11/12010. 12/312010 •00 0 5 Flno Sao Gradug Description For Sou Stamina Moasuros, trio Apply sou sabluors to tnnc0v0 areas mld0atlon toaucas omisslom by: PM10: 84%PM25:64% For Soo 81ab114q Mo0nuros, the Roche ground cover In simonised areas quIclty meigetlon reduces ordseimu by: P1M0:6% PM26:5% For Soil Slabbing Meoeur0e, the Water exposed sudacas 24 dolly waatlng mulg0tlon roduaos Gmisslons by: PM10: 65%PM26: 56% Fa Unpovod Roads Mansura', tlw Reduce speed on unpevad toads to loss than 15 mph mitlge0on reduces omissions by: PM10: 44% PM26: 44% For Unpevad Roads Measures, IN Menage haul road dust 2x daily walori g mNgallon reduces amlesla» by: PM10: 65% PM26: 65% Page: 7 4122)201012:20:21 PM For graders, One Dlose( Paniptalo Attar (DPF) 1st 11er mitigation roduest amlaslona by; PM10: 85% PM25: 85% For Graders, tiro 0bsol Oxklalbn Catalyst 16% mitigation aducce omissions by: NOX: 16% For Rubber Ned Dozers, da Dloul Partetate Fitter (DPF) 1e1 Tier mitigation reduces ombdass by: PM10: 05% PM26: 05% For Rubber Nod Dozers, ono Dlosal Oxidation Catalyst 16% mitigation reduces 004040ng by: NOX: 15% Far TractorsOnadeninackhoos, 010 Dleset Penkadalo Flitor (DPF) IN Tbt macadam reduces emissions by: PM10:05% PM25:05% For Tractorskaadarafilackhoas, the Dlesal Oxidation Catalyst 16% mitigation asthma, emissions by: NOX: 15% For Wets Truck*, the Diesel Pan:a Tate Flier (DPF) let Tier Mdg0tari loch/cos emissions by: PM10:85%PM2$:85% For Mato, Trucks, the Diesel Odda0on Catalyst 15% mitigation roducoa emissions by: NOX: IS% For Slid Stem t.oadars, the Colossi Partiedate Filler (OPF) Ist Ter mkug00on aim os arrissia:s by: PM10: 85% P1.125: 85% For slid Steer loaders, the dotal Oddatlon Catalyst 15% mrogoaan reduces emissions by: NOX: 15% The tireMst mitigation measuroe eppy to Phase: Pavig 6/12011 . 12/312011 •Oelaua PoNag Doccdpnan For Cement and Matter Mirara. 0a Otosel Para:Mato Flier (DPF) tat Tier ni08aeon roduoo0 emissions by: PM10: 85% P1.25: 85% For Cement and staler Mast., 0 0 Olosel Oddalion Catalyst 15%mitigation reduces emissions by: NOX: 15% For Pavers, the Diesel Panterno 1ior (DPF) t M Tier oitlgo0on (Owes emissions by: PM10; 85% PM25: 85% For Pavers, 0a Diesel 0a5da11on Catalyst 16% midgatbn Wools amiss:ma by: NOX: 16% For Roque, 0a dotal Penkuato FOfar (DPF) 1 al Ter attrition reduces omllalons by: Page:8 4/22201012:20:21 PM PM10: 85%PM26: 85% For Rollers, 0a Meant Oddatian Catalyst 15% ralgaOon reduces omissions by: NOX: 15% For Tr0daKoadera/13oWaoe, to Diesel Pankuato Flnar (DPF) tat Tier 'natation reduces emissions by: PM10: 85% P1A25: 85% For TI0GON-aad0te/Dadd000a, tee Metal Odda1on Catalyst 15% [natation reduces ,missions by: NOX: 1S% For Paving Egtpnam, tla Dena PONwaa Mbar (DPF) 1st Ter mitt Mon reduces emissions by: PM10: 85% PM25: 05% Fa Paving Equipment the doses 07/sdadan Catalyst 15% mitigation reduces emissions by: NOX:16% The Iodoorq mitigation mammas apply to Phase; Bu0005 Construction 1112011 • 12/3120/1 - Default DAWN Construction Description For Cranes, die Diesel PMlalate Filter (DPF) 1st Ter rrc0gatlon radix:of omissions by. PM10:85% PM26; 05% For Cranes, the Wesel Oxidation Catalyst IS%mitigation radixes emissions by: NOX: IS% For Pandits, do dotal Ptu0tulat0 Fear (OPF) 1st Tlef mitigation radius emissions by: PM10: 85%PM25:85% For FOd18s, tin OMNI0x:dation Caayst IS% ni0gatbn reduces omissions by: NOX: IS% For Tmcare4.0adoNBackhooe, Ua d0u1 Pordculaa Fluor (DPF)1st Tar nangaaon raducas emissions by: PMIO:85%PM26:85% Fa Conoco Sots.lho Diesel Particulate, Flier (DPF) 1st Tar mitigation rodocus embaions by: PM10: 85% PM25: 85% For oanronr Sala, the Maui °Mattta Caloyal 16% agitation reducer' omissions by: NOX: 16% For Welders, the Diesel Particulate Flier (DPF) del Ter mlti5Od0n rodu0os emissions by: PM10: 85%PM25:05% For Walden, Oho Oeul Oddatbn Catalyst 15% mitigation rodu00e omisalons by: NOX: 15% Pago:9 4/22/201012:20:1 PM Tin ioaosi g 11114211n moaauros apply to Phase: Atchhodurol Coatag 01 VN11 •12/312011 • Saba It Arddtoctuml Coating Oosc4ption For Rosldomdnl Ard.toctural Coatlrp Moasuros, the Rasidendol Esorlon Usti Low VOC o0atin0s ml0Jati0D reduces missions by: R00:10% Far Rasldanaal Arddadurd CooU g 14o0suros, the, Residential Interior; Use Low VOC Coatings mitigation reduces omissions by: R00:10% For Nonrasldon09l Architectural Coating Moosuros, lln Nonrosldon0al Esto0on Uso Low VOC Coatings m0$ oOo0 radocos emissions by: R00:10% For NomosldcnUal Ard0lactural Coaling Measures, the Nonrasldontial Inlorior: Uao low VOC Coatings mitigation rodu0os omissions by: R03:10% • Ansa Source Unn00gotod Ooloi Report AREA SOURCE EMISSION ESTIMATES Annual Tom Par Year, UnrNtigatod Smuto HO(i ti00 al • 002 CM10 EMU 002 Natural Om 0.01 0.10 0.00 0.00 0.00 0.00 202.47 600101 033 0.02 1,21 0.00 0.10 0.16 30.10 l.mtdscapa 047 0.01 0.65 0.00 020 0.00 1.13 Canwmor Products 0.51 AroNtadural Coatings 0.17 TOTALS (tans/you, unmalgat0d) 1.09 0.19 1,04 0.00 0.10 0,18 ' 233.70 Aran Rome 015 gn%to D01411s Page: 10 422/201012:2021 PM Opora0m;a1 Una:f9 tedoo1a0 Report: OPERATIONAL EMISSION ESTIMATES Annual Tons Pot Yonr, Urvnalg0lod `J90[SO ROO NOX CO 502 PM10 P1425 CO2 Single lamlly housing 0.63 0.03 7,01 0.01 1.21 . 0.23 653.10 Retirement community 0A8 0.00 0.59 0,00 ' 0.09 0.02 5028 High tunover(Nldofw) rant. 0.71 1,03 8.11 0.01 1,40 026 709,01 nip mall 0.69 0.84 7,38 0.01 1,21 0R3 848.45 TOTALS (tonsyoar, won0galad) 1,99 2.70 24.00 0.03 4.00 0.70 2,161.74 Op0r5808 1 Settings: 0aos not Indu4o0onedlon for p0as0y taps Oous not Indudedouttemumhg miles:mint for internal trips MNysls Yea02011 Season: Annual Emlao: Vorden : Emlaa2007 V2.3 Nov 12000 '511MmaNal I and 111p6 Land Uso Typo Acreage Trip Rato IJa5 Typo No. Units Talol Trips Total VMT Single family housing 2.98 9.57 dwailing010o 47.00 449.70 3,845.57 Rodronant community 1,42 3.47 dwaling units 10.00 34,70 200.67 High tulnaoor (slldo*n) rosl 12129 1000 aq a ' 5.20 837,00 4,757,70 Gulp mall 4432 1000 so it 11,78 622.00 3,650.81 1,044.57 12,759.83 Page:11 4/22/20l012:20:21 PM VONdo Type light Mno tight Ruck a 3750105 U9hl Truck 3751.57501Ma Mod Truck 5751450001s LIN•Hoavy Truck 8501.10.0001bs Uto•Heavy Truck 10.001.14,000 es Mod'Noa y Truck 14,001.33,00011s Hosvy4Ho0vy Truk 33,001. 30,000I bs Otter Sus Urban Bus Mdoaydo School Blla Moor Homo Urban Tdp Long% (mllea) Rum, Tdp Length (80oi) TA) sp00ds(mph) %ofTdps • Raakfo0Onl Page: 12 4722/201012120:21 PM % olTdps • Commercial (by land usai High tomovor (544o6n) roll 6166 mall Vehldo Root MN Porcont Typo NonCmolyst Catalyst Diosol 63.0 0.9 08.7 0.4 12.0 1.8 95.3 3.1 19.8 AS 80.5 0A 6.0 0.0 100,0 0.0 0,9 0.0 77,8 222 08 0,0 50.0 50.0 1.0 0,0 20.0 80.0 0.4 00 0.0 100.0 0.1 0.0 0.0 100,0 0.1 0.0 0.0 100.0 3.2 625 37,5 OA 0.7 0.0 0.0 100.0 0.6 0.0 a7.3 , 16.7 Trawl CondNions Rosidon0al Commardol Homa•Work lloma'Shop Horm'Othar Cammulo Non.Walk Sustoma r' 10.8 7.3 7.5 9S 7,4 7.4 16.8 7.1 7.9 14,7 0.0 8.8 35.0 35.0 35.0 35.0 35.0 35.0 32.9 18.0 49.1 Thrall Certddlona Rosidaml0l Homo -Work Homo'Shop Homo•Othor Qoarellonel C.hangaa to 001me1 Coou90 :1M Commute Nan•Work CaslOmOr 6.0 2.0 2,5 92.5 1.0 97.0 Table 1 Annual Non -Transportation Consumption/Generation Land Use Unit Electricity Nat. Gas Solid Waste Water (MWHR) (106 cu ft) (tons) (106 gal) • Residential SF Senior Housing Retail Restaurant DU 4.40 DU 2.20 KSF 13.55 Seats or KSF 47.45 0.0481 0.0240 0.0348 0.0576 0.73 0.75 2.40 1.72 0.064 0.041 0.032 0.0878 Conversion to CO2(e) [tons/year] Electricity MWHR x 0.364 tons/MWHR (1) Nat. Gas 106 cubic feet x 54.6 tons/106 cubic feet (2) Solid Waste tons x 0.46 tons/ton (3) Water and Wastewater 106 gal(MG) x 1.46 tons/MG (4) (1) California Climate Action Registry (2) California Climate Action Registry (3) Energy Information Admin., Voluntary Reporting of GHG (4) California Energy Commission, Integrated Energy Policy Report (12.7 MWHR per MG conveyed, treated and disposed in Southern California) Table 2 Project -Related GHG Emissions (2011) 2011 Unit Electricity (MWHR) Nat. Gas (106 cult) Solid Waste (tons) Water (MG)) Residential (SF) 47 DU 207 2.26 34.3 3.0 Senior Housing 10 DU 22 0.24 3.7 , 0.4 Restaurant 5.265 KSF 250 0.30 9.0 0.4 Retail 11.8 KSF 160 0.41 28.3 0.5 Total 639 3.21 15.3 4.3 Conversion Factor 0.364 54.6 0.46 1.46 CO2(e) tons/yr 232.6 175.3 34.6 6.3 Total Non -Transportation 449 tons/year Total Transportation* 2,152 tons/year Combined tons C0z(e)/yr 2,601 "short" tons = 2,365 metric tons Transportation Share 83% Residential and retail = 365 days/yr INITIAL STUDY -16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD ATTACHMENT 3 RECOMMENDATIONS FROM A TREE INVENTORY AND REVIEW OF THE PROPOSED DEVELOPMENT AT 16005 Los GATOS BOULEVARD Los GATOS, CALIFORNIA BY ARBOR RESOURCES OCTOBER 11,2010 David L. Babby, Registered Consulting Arborisi® October 11, 2010 5.0 RECOMMENDATIONS Recommendations presented within this section are based on the design reviewed, and serve as guidelines for avoiding or mitigating impacts to trees being retained, removed or relocated. They should be carefully followed and incorporated into the project plans, and are subject to revision upon reviewing any additional or revised plans. 5.1 Design Guidelines 1. The recommendations and setbacks provided in Section 4.0 of this report should be followed or considered. 2. All existing, unused lines or pipes beneath the canopies of retained trees shall be abandoned and cut off at existing soil grade (rather than being dug up and causing subsequent root damage). 3. The permanent and temporary drainage design, including downspouts, should not require water being discharged towards a tree's trunk. 4. Per Section 29.10.1000(C.1) of the Ordinance, a copy of this report must be incorporated into the final set of project plans; titled Sheets T-1, T-2, etc. ("Tree Protection Instructions"); and referenced on all site -related project plans. 5. Mitigation is necessary to compensate for the loss of trees removed. Pursuant to Section 29.10.0985 of the Town Code, this shall be determined by the Parks and Public Works Department. I recommend that Table 3-1 of Section 29.10.0985 of the Town Code is used as the framework for determining the size and amount of new trees to install. The trees shall be planted prior to final inspection, double -staked with rubber tree ties (may not be necessary for trees of 48-inch box size and larger), and all forms of irrigation be of an automatic drip or soaker hose system placed on the soil surface and not in a sleeve. Additionally, to achieve the greatest assurance of 16005 Los Gatos Boulevard, Los Gatos Page 6 of 9 Town of Los Gatos Community Development Department David L. Babby, Registered Consulting Arborisl® October 11, 2010 proper installation, all new trees shall be installed, including necessary irrigation, by an experienced state -licensed landscape contractor or a professional tree company. 6. The landscape design should incorporate the following guidelines: a. For tree #9 the grates surrounding its trunk should be removed, and the existing planter enlarged. b. Most of the brush cherry trees (#23 thru 33) along the front, western section of the property should be retained as an existing screening element (the ones retained should also be pruned). c. Water should be supplied to the street trees in the form of a drip- or bubbler -type system established on -grade and not in a sleeve. d. Within planter areas containing trees, I suggest a four -inch layer of coarse wood chips or other high -quality mulch is used as ground cover (no gorilla hair, bark, rock/stone or black plastic). e. Irrigation should not strike within 12 to 24 inches from a tree's trunk. f. In the event trenches for irrigation and/or lighting are required beneath a canopy, they shall be installed in a radial direction to the trees' trunks. If irrigation trenches cannot be routed as such, the work should be performed using a pneumatic air device (such as an Air -Spade®). g. Mulch should be placed no closer than three inches from a tree's trunk. h. Tilling beneath canopies should be avoided, including for weed control. i. Bender board or other edging material proposed beneath the canopies should be established on top of existing soil grade (such as by using vertical stakes). 5.2 Protection Measures before and during Construction 7. All recommendations presented in Section 5.1 of this report shall be followed. 8. Tree protective fencing shall be erected to restrict access into unpaved areas beneath the canopies of retained trees. Where it is placed along existing hardscape, it should be no farther than 12 inches from the hardscape edge. It shall be installed prior to any demolition, trenching, soil scraping, or construction, and comprised of five- to 16005 Los Gatos Boulevard, Los Gatos Page .7 of 9 Town of Los Gatos Community Development Department David L. Babby, Registered Consulting Arborisl® October 11, 2010 six-foot high chain link mounted on two-inch diameter steel posts that are driven at least two feet into the ground and spaced no more than 10 feet apart. Once established, the fencing shall remain in place and be undisturbed throughout construction until final inspection. 9. Unless otherwise approved, all development activities must be conducted beyond any unpaved areas beneath the trees' canopies. These activities include, but are not limited to, the following: demolition, grading, stripping of topsoil, trenching, equipment cleaning, stockpiling/dumping of materials, and equipment/vehicle operation and parking. Tree trunks must also not be used as winch support for transporting or lifting heavy loads. 10. Prior to construction, a four -inch layer of coarse wood chips ('/a- to 3/a-inches in size) from a local tree service company shall be manually spread within the fenced -areas. 11. Any approved activity required on unpaved areas beneath the trees' canopies must be manually performed using hand tools and wheelbarrows, and not require heavy equipment or tractors traveling or operating on unpaved ground. 12. If a section of new property fence is to be installed, the posts should be situated at least 24 inches from any trunk, and manually dug using a post -hole digger. In the event a root of two inches and greater in diameter is encountered during the process, the hole should be shifted over by about 12 inches and the process repeated. 13. Great care should be taken by construction personnel and any heavy equipment operator to avoid damaging tree trunks, limbs and branches. 14. Where beneath canopies of retained trees, the removal of existing hardscape must be carefully performed to avoid excavating soil and damaging roots during the process. This work should not involve the use of heavy equipment or tractors operating or traveling on unpaved soil. 16005 Los Gatos Boulevard, Los Gatos Page 8 of 9 Town of Los Gatos Community Development Department David L. Babby, Registered Consulting Arborisfl October 11, 2010' 15. Throughout construction during the months of March thru November, supplemental. water should be supplied. to the retained trees. In doing so, I recommend a rate of approximately five to ten gallons per inch of trunk diameter is applied to the ground beneath the canopies (and not at the trunks) every two weeks via deep -root soaking, such as using soaker hoses or filling a basin formed by a 1.2-inch high berm. 16. All tree pruning shall be performed in accordance with the most recent ANSI standards, and by a California state -licensed tree service company that has an ISA (International Society of Arboriculture) certified arbori.st in a supervisory role. The company selected should also carry General' Liability and Worker's Compensation insurance, and shall abide by ANSI Z133,1-2006 (Safety Operations). All pruning should be limited to the removal. of deadwood ?1 in diameter, heavy limb weight reduction,. and clearance for vehicles and equipment. 17. Tree relocation shall performed according to the standards set forth in ANSI A300 (Part 6)-2005 Transplanting, and by a company described in the previous recommendation. All recommendations provided by the company for pre-, during and post -transplant care shall be followed. 18. The disposal of harmful products (such as cement, paint, chemicals, oil and gasoline) is prohibited beneath canopies or anywhere on site that allows drainage beneath canopies, Herbicides should not be used beneath the trees' canopies; where used on site, they should: be labeled. for safe use near trees. Prepared By: David L. Babby Registered Consulting Arborie #399 Board -Certified Alasler Arborist #! E-400:1.13 Date: October 11., 2010 16005 Los Gatos Boulevard, Los Gatos Town of Los Gatos Community Development Department Page 9 of,9 INITIAL STUDY -16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD ATTACHMENT 4 RECOMMENDATIONS FROM UPDATED GEOTECHNICAL INVESTIGATION FOR MIXED -USE DEVELOPMENT 16005 Los GATOS BOULEVARD Los GATOS, CALIFORNIA BY CORNERSTONE EARTH GROUP OCTOBER 21, 2009 r�i'p CORNERSTONE =71 EARTH GROUP site where lateral spreading could occur and the potential for liquefaction is low; therefore, in our opinion, the potential for lateral spreading to affect the site is low. 4.5 SEISMIC SETTLEMENT/UNSATURATED SAND SHAKING Loose unsaturated sandy soils can settle during strong seismic shaking. With the range of blow counts found in the lower portions of the environmental excavation fill, the estimated static settlements of foundations with anticipated column loads of 400 kips was found to be about 11/2 to 31/2 inches, with the same anticipated loads for the native soils were found to be 1/3 to 1/2 inch. Static settlements of the wail foundations with the anticipated loads of 4 to 6 kips per lineal foot for the native soils were found to be less than 0.1 inch to about'/ inch. This differential settlement is beyond normally acceptable limits of differential settlement of fill and native soils, especially without a transition between the differential settlement locations. Likewise, the estimated seismic dry sand settlement of foundations with the same anticipated loads was found to be about 11/4 to 41/2 inches and the seismic dry sand settlement of the foundation on native soils with the same anticipated loads was found less than inch. This differential settlement is also beyond normally acceptable limits for differential seismic dry sand settlement. As discussed above, the native soils are dense to very dense and it is our opinion, the potential for significant differential seismic settlement in the native soils affecting the proposed improvements is low. However, the loose fill in the environmental excavation is susceptible to several inches of settlement as a result of strong earthquake shaking as discussed in the subsurface section of the report. We recommend that this material be removed and recompacted to mitigate this concern. Recommendations are presented in the earthwork section of the report. SECTION 5: CONCLUSIONS From a geotechnical viewpoint, the project is feasible provided the concerns listed below are addressed in the project design. Descriptions of each concern with brief outlines of our recommendations follow the listed concerns, • Temporary excavations in close proximity of property lines, shoring and underpinning support of adjacent structures during construction. • Presence of boulders and cobbles that can interfere with earthwork, trenching, drilling and compaction operations. • Waterproofing and drainage of below grade retaining walls. • Undocumented fill in the vicinity of Boring EB-1 and other areas, as well as loose fill in the environmental excavation. • Proximity of the site to a mapped portion of the Monte -Vista Shannon fault. Mixed Use Development 16005 Los Gatos Boulevard 156.2-2 Page 6 CORNERSTONE . EARTH GROUP 5.1 TEMPORARY EXCAVTIONS, SHORING AND UNDERPINNING Vertical excavations, generally in the upper 12 to 14 feet, are anticipated to construct the one - level below -grade for parking immediately adjacent to the property lines. It should be the contractor's responsibility to design and install stiff enough shoring systems or other systems to avoid distress to the adjacent existing structures and any nearby improvements due to deflection of the shoring systems. If required, it should be the contractor's responsibility to design and install underpinning support of adjacent existing structures. Recommendations are presented in the `Temporary Slopes, Trench Excavations Shoring and Underpinning" section below. 5.2 PRESENCE OF BOULDERS AND COBBLES Soii deposits at the site include boulders and cobbles that can interfere with earthwork, trenching, drilling, and compaction operations. Encountering such conditions should be anticipated and earthwork operations should be performed in accordance with the applicable recommendations in this report. 5.3 WATERPROOFING AND DRAINAGE OF BELOW GRADE RETAINING WALLS Retaining walls should be waterproofed and drainage systems should be installed behind the walls to remove free water that might migrate to the back of the wall. A waterproofing consultant should be contacted for waterproofing designs. Geotechnical recommendations for design of retaining walls are presented in the "Retaining Walls" section of this report. 5.4 UNDOCUMENTED FILL AND LOOSE FILL IN THE ENVIRONMENTAL EXCAVATION Loose fill is present in the backfilled environmental excavation and undocumented fill is present in the vicinity of Boring EB-1. In addition, undocumented fill may be present in other areas, of the site and should be expected. The backfili material in previous environmental excavation below the proposed basement excavation subgrade elevation and any other fill should be removed. The approximate limits of the environmental excavation are shown on the Site Plan, Figure 2. Excavations extending below the planned finished site grades should be cleaned and backfilled with suitable material compacted as recommended in the "Compaction" section of this report. If mitigation of this area is performed prior to site demolition, it may be necessary to demolish portions of the adjacent existing buildings so that the sidewalis of the excavation will meet safety standards. The east side of the environmental excavation is immediately adjacent to one of the existing buildings. It appears as though some demolition of this building will be necessary so that the 1:1 (horizontal to vertical) temporary cut slope can be made. This cut would result in earthwork for the excavation extending about 30 feet beyond the bottom of the excavation extending about 30 feet beyond the bottom of the excavation. The new earthwork to remove the existing backfitl in the environmental backfill should be performed while a representative of our office is present. Mixed Use Development 16005 Los Gatos Boulevard 156-2-2 Page 7 CORNERSTONE EARTH GROUP As mentioned above, fill In the vicinity of Boring EB-1 is present. However, as the excavation for the below grade parking will extend about 12 feet below grade, these fills may be removed and exported as part of the basement excavation process. Hydraulic lifts may still be present below the existing grade In service bays within some of the existing building areas. Associated pipelines may also be present. The site should be cleared of all existing hydraulic lifts and related below grade pipelines. We anticipate that hydraulic lifts would not extend below the bottom of the garage excavation, However, if they extend below the planned finished grade, the portion of the excavation that extends below the graded should be cleaned and backfilied with suitable material as discussed in the "Compaction" section of this report. 5.5 PROXIMITY OF THE SITE TO A MAPPED CONCEALED PORTION OF THE MONTE- VISTA SHANNON FAULT As discussed in Appendix C, the site is not located within a currently designated Alquist-Priolo Earthquake Fault Zone, known formerly as a Special Studies Zone, but is located in a Santa Clara County fault rupture hazard zone and is located in a "moderate" fault rupture zone according to the Town of Los Gatos. Based on the information available to us at this time, the probability for fault rupture to occur through the site during the lifetime of the project is considered low. We recommend that the excavation for the below -grade parking level be examined by a certified engineering geologist while the earthwork is being performed to determine if the Shannon Fault crosses the site or related coseismic deformation may affect the site. See Appendix C for further details. 5.6 PLANS AND SPECIFICATIONS REVIEW We recommend that we be retained to review the geotechnical aspects of the project structural, civil, and landscape plans and specifications, allowing sufficient time to provide the design team with any comments prior to issuing the plans for construction. 5.7 CONSTRUCTION OBSERVATION AND TESTING As site conditions may vary significantly between the small -diameter borings performed, we also recommend that a Cornerstone representative be present to provide geotechnical observation and testing during earthwork and foundation construction. This will allow us to form an opinion and prepare a letter at the end of construction regarding contractor compliance with project plans and specifications, and with the recommendations In our report. We will also be allowed to evaluate any conditions differing from those encountered during our investigation, and provide supplemental recommendations as necessary. For these reasons, the recommendations in this report are contingent of Cornerstone providing observation and testing during construction. Contractors should provide at least a 48-hour notice when scheduling our field personnel. Mixed Use Development 16005 Los Gatos Boulevard 156-2-2 Page 8 MI CORNERSTONE EARTH GROUP SECTION 6: EARTHWORK 6.1 SITE DEMOLITION, CLEARING AND PREPARATION 6.1.1 Site Stripping The site should be stripped of all surface vegetation, and surface and subsurface improvements within the proposed development area. Demolition of existing improvements is discussed in detail below. A detailed discussion of removal of existing fills is provided later in this report. Surface vegetation and topsoil should be stripped to a sufficient depth to remove all material greater than 3 percent organic content by weight. Based on our site observations, surficial stripping should extend about 2 to 4 inches below existing grade in vegetated areas, with the exception of tree areas which are discussed below. 6.1.2 Tree and Shrub Removal Trees and shrubs designated for removal should have the rootbalis and any roots greater than 1/2-inch diameter removed completely. Excavations down to about 2 to 3 feet below grade may be needed to remove tree roots; this will be done as part of the garage excavation. Grade depressions resulting from rootball removal should be cleaned of loose material and backfilied in accordance with the recommendations in the "Compaction" section of this report. 6.1.3 Demolition of Existing Slabs, Foundations and Pavements All slabs, foundations, and pavements should be completely removed from within planned building areas. A discussion of recycling existing improvements is provided later in this report. 6.1.4 Abandonment of Existing Utilities All utilities should be completely removed from within planned building areas. For any utility line to be considered acceptable to remain within building areas, the utility line must be completely backfilied with grout or sand -cement slurry (sand slurry is not acceptable), the ends outside the building area capped with concrete, and the trench fills either removed and replaced as engineered fill with the trench side slopes flattened to at least 1:1, or the trench fills are determined not to be a risk to the structure. The assessment of the level of risk posed by the particular utility line will determine whether the utility may be abandoned in place or needs to be completely removed. The contractor should assume that all utilities will be removed from within building areas unless provided written confirmation from both the owner and the geotechnicai engineer. Utilities extending beyond the building area may be abandoned in place provided the ends are plugged with concrete, they do not conflict with planned improvements, and that the trench fills do not pose significant risk to the planned surface improvements. The risks associated with abandoning utilities in place include the potential for future differential settlement of existing trench fills, and/or partial collapse and potential ground loss into utility Mixed Use Development 18005 Los Gatos Boulevard 156-2-2 Page 9 CORNERSTONE . EARTH GROUP lines that are not completely filled with grout. In general, the risk Is relatively low for single utility lines less than 4 inches In diameter, and Increases with increasing pipe diameter. 6.2 REMOVAL OF EXISTING FILLS All fills, including fill in the environmental excavation, should be removed vertically and laterally to firm, undisturbed native soil. Side slopes of fill excavations in building and pavement areas should be sloped at Inclinations no greater than 3:1 (horizontal to vertical) to•minimize abrupt variations in fill thickness. However, the sidewalls in the environmental excavation should be sloped at inclinations no greater than 1:1 (horizontal to vertical). As mentioned above, it may be necessary to demolish adjacent, existing buildings. The subgrade should be scarified, moisture conditioned to near optimum moisture content and compacted in accordance with the recommendations for fill presented in the "Compaction" section of this report. Fill should be benched into the sidewalls of excavation with approximate 2 foot wide, 2 foot high benches. If the fill material meets the requirements in the "Material for Fill" section below, it may be reused as engineered fill. All fill should be compacted in accordance with the recommendation for fill presented in the "Compaction" section of this report. Removal, replacement and compaction of fill should occur while a representative of our firm is present to document earthwork operations and compaction of the subgrade and the fill. 6.3 TEMPORARY CUT AND FILL SLOPES The contractor Is responsible for maintaining all temporary slopes and providing temporary shoring where required. Temporary shoring, bracing, and cuts/fills should be performed in accordance with the strictest government safety standards. On a preliminary basis, the upper 20 feet at the site may be classified as OSHA Site B materials. Recommended soil parameters for temporary shoring are provided in the "Temporary Shoring" section of this report. 6.4 SUBGRADE PREPARATION After site clearing and demolition is complete, and prior to backfilling any excavations resulting from fill removal or demolition, the excavation subgrade and subgrade within areas to receive additional site fills, slabs -on -grade and/or pavements should be scarified to a depth of 6 inches, moisture conditioned, and compacted in accordance with the "Compaction" section below. Due to the sandy soils likely to be encountered at the subgrade elevation, we suggest recommend that subgrade compaction and proof rolling be performed within 24 hours of capillary break layer or slab -on -grade construction. 6.5 MATERIAL FOR FILL 6.5.1 Re -Use of On -site Soils On -site soils with an organic content Tess than 3 percent by weight may be reused as general fill. General fill should not have lumps, clods, cobble, or boulder pieces larger than 8 inches In diameter; 50 percent of the fill should be smaller than 21/x inches in diameter. Minor amounts of Mixed Use Development 18005 Los Gatos Boulevard 156-2-2 Page 10 Min CORNERSTONE p EARTH GROUP oversize material (smaller than 12 inches in diameter) may be allowed provided the oversized pieces are not allowed to nest together and the compaction method will allow for loosely placed lifts not exceeding 12 inches, such an 815 or REX compactor. The contractorshould anticipate removing some oversized materials (Le. boulders larger than 12 inches) from the existing soils prior to reuse as fill. 6.5.2 Potential Import Sources Imported and non -expansive material should be inorganic with a Plasticity index (Pi) of 15 or Tess, and not contain recycled asphalt concrete where it will be used within interior habitable building areas. To prevent significant caving during trenching or foundation construction, imported material should have sufficient fines. Samples of potential import sources should be delivered to our office at least 10 days prior to the desired import start date. Information regarding the import source should be provided, such as any site geotechnical reports. If the material will be derived from an excavation rather than a stockpile, potholes will likely be required to collect samples from throughout the depth of the planned cut that will be imported. At a minimum, laboratory testing will include PI tests. Material data sheets for select fill materials (Class 2 aggregate base, 3/4-inch crushed rock, quarry fines, etc.) listing current laboratory testing data (not older than 6 months from the import date) may be provided for our review without providing a sample. If current data is not available, specification testing will need to be completed prior to approval. Environmental and soil corrosion characterization should also be considered by the project team prior to acceptance. Suitable environmental laboratory data to the planned import quantity should be provided to the project environmental consultant; additional laboratory testing may be required based on the project environmental consultant's review. The potential import source should also not be more corrosive than the on -site soils, based on pH, saturated resistivity, and soluble sulfate and chloride testing. 6.6 COMPACTION REQUIREMENTS All fills, and subgrade areas where fill, slabs -on -grade, and pavements are planned, should be placed in loose lifts 8 inches thick or Tess and compacted in accordance with ASTM D1557 (latest version) requirements as shown in the table below. In general, clayey soils should be compacted with sheepsfoot equipment and sandy/gravelly soils with vibratory equipment; open - graded materials such as crushed rock should be placed in lifts no thicker than 18 inches consolidated in place with vibratory equipment. Each lift of fill and all subgrade should be firm and unyielding under construction equipment loading in addition to meeting the compaction requirements to be approved. The contractor (with input from a Cornerstone representative) should evaluate the in -situ moisture conditions, as the use of vibratory equipment on soils with high moistures can cause unstable conditions. Mixed Use Development 16005 Los Gatos Boulevard 156.2.2 Page 11 El CORNERSTONE EARTH GROUP General backfill over shading materials may consist of on -site native materials provided they meet the requirements in the "Material for Fir section, and are moisture conditioned and compacted in accordance with the requirements in the "Compaction" section. Where utility lines will cross perpendicular to strip footings, the footing should be deepened to encase the utility line, providing sleeves or flexible cushions to protect the pipes from anticipated foundation settlement, or the utility lines should be backfilled to the bottom of footing with sand- cement slurry or lean concrete. Where utility lines will parallel footings and will extend below the "foundation plane of influence," an imaginary 1:1 plane projected down from the bottom edge of the footing, either the footing will need to be deepened so that the pipe is above the foundation plane of influence or the utility trench will need to be backfilled with sand -cement slurry or lean concrete within the influence zone. Sand -cement slurry used within foundation influence zones should have a minimum compressive strength of 75 psi. 6.8 SITE DRAINAGE Ponding should not be allowed adjacent to building foundations, slabs -on -grade, or pavements. Hardscape surfaces should slope at least 1 percent towards suitable discharge facilities; landscape areas should slope at least 2 percent. Roof runoff should be directed away from building areas. 6.9 BELOW -GRADE EXCAVATIONS Below -grade excavations may be constructed with temporary slopes in accordance with the "Temporary Cut and Fill Slopes" section above if space allows. Alternatively, temporary shoring may support the planned cuts up to 14 feet. We have provided geotechnical parameters for shoring design in the section below. The choice of shoring method should be left to the contractor's judgment based on experience, economic considerations and adjacent improvements such as utilities, pavements, and foundation loads. Temporary shoring should support adjacent improvements without distress and should be the contractor's responsibility. A pre -condition survey including photographs and installation of monitoring points for existing site improvements should be included in the contractors scope. We should be provided the opportunity to review the geotechnical parameters of the shoring design prior to implementation; the project structural engineer should be consulted regarding support of adjacent structures. 6.9.1 Temporary Shoring Based on the site conditions encountered during our investigation, the cuts may be supported by soldier beams and tie -backs, braced excavations, soil nailing, or potentially other methods. Where shoring will extend more than about 10 feet, restrained shoring will most likely be . required to limit detrimental lateral deflections and settlement behind the shoring. In addition to soil earth pressures, the shoring system will need to support adjacent loads such as construction vehicles and incidental loading, existing structure foundation Toads, and street loading. We recommend that heavy construction Toads (cranes, etc.) and material stockpiles be kept at least 15 feet behind the shoring. Where this loading cannot be set back, the shoring will need to be designed to support the loading. The shoring designer should provide for timely and Mixed Use Development 18005 Los Gatos Boulevard 158-2.2 Page 13 CORNERSTONE 1.74, EARTH GROUP Table 2: Compaction Requirements Description Material Description Mtnimurn Relative Compaction (percent) Moisture 2 Content (percent) General Fill (within upper 5 feet) On -Site Low Expansion Soils 90 >1 General Fill (below a depth of 5 feet and beneath footings) On -Site Low Expansion Soils 95 >1 Basement Wall Backfiil Without Surface Improvements 90 >1 Basement Wall Backfili With Surface improvements 954 >1 Trench Backfill On -Site Low Expansion Soils 90 >1 Trench Backflll (upper 6 Inches of subgrade) On -Site Low Expansion Soils 95 >1 Crushed Rock Fill 314-inch Clean Crushed Rock Consolidate in -Place NA Non -Expansive Fill Imported Non -Expansive Fill 90 Optimum Flatwork Subgrade On -Site Low Expansion Soils 90 >1 Flatwork Aggregate Base Class 2 Aggregate Bases 90 Optimum Pavement Subgrade On -Site Low Expansion Soils 95 - >1 Pavement Aggregate Base Class 2 Aggregate Bases 95 Optimum Asphalt Concrete Asphalt Concrete 95 (Marshall) NA 1 — Relative compaction based an maximum density determined by ASTM D1557 (latest version) 2 -- Moisture content based on optimum moisture content determined by ASTM D1557 (latest version) 3 — Class 2 aggregate base shall conform to Caltrans Standard Specifications, latest edition, except that the relative compaction should be determined by ASTM D1557 (latest version) 4 — Using Tight -weight compaction or walls should be braced 6.7 TRENCH BACKFILL Utility lines constructed within public right-of-way should be trenched, bedded and shaded, and backfilled in accordance with the local or governing jurisdictional requirements. Utility lines in private improvement areas should be constructed in accordance with the following requirements unless superseded by other governing requirements. All utility lines should be bedded and shaded tout least 6 inches over the top of the fines with crushed rock (%-inch-diameter or greater) or well -graded sand and gravel materials conforming to the pipe manufacturer's requirements. Open -graded shading materials should be consolidated in place with vibratory equipment and well -graded materials should be compacted to at least 90 percent relative compaction with vibratory equipment prior to placing subsequent backfill materials. Mixed Use Development 16005 Los Gatos Boulevard 156.2-2 Pap 12 ElCORNERSTONE : EARTH GROUP uniform mobilization of soil pressures that will not result in excessive lateral deflections. Minimum suggested geotechnical parameters for shoring design are provided in the table below. Table 3: Recommended Temporary Shoring Design Parameters Design Parameter Design Value Minimum Lateral Wall Surcharge (upper 5 feet) 120 psf Cantilever Wall — Triangular Earth Pressure 40 pcf Restrained Wall — Trapezoidal Earth Pressure Hinge points at H/4 and 3/4H (feet) Increase from 0 to 25H" psf Restrained Wall — Uniform Earth Pressure 25H* Passive Pressure —Starting at the bottom of the excavation 420 pcf up to 2,000 psf maximum uniform pressure " H equals the height of the excavation; passive pressures are assumed to act over twice the soldier pile diameter The restrained earth pressure may also be distributed as described in Figure 24 of the FHWA Circular No. 4 — Ground Anchors and Anchored Systems provided the total pressure is established from the uniform pressure above. If shotcrete lagging is used for the shoring facing, the permanent retaining wall drainage materials, as discussed in the `Wall Drainage" section of this report, will need to be Installed during temporary shoring construction. At a minimum, 2-foot-wide vertical panels should be placed between soil nails or tiebacks that are spaced at 6-foot centers. For 8-foot centers, 4- foot-wide vertical panels should be provided. A horizontal strip drain connecting the vertical panels should be provided, or pass -through connections should be included for each vertical panel. The borings were performed with hollow -stem auger drilling equipment and as such were not able to evaluate the potential for caving soils, which can create difficult conditions during soldier beam, tie -back, or soil nail installation; caving soils can also be problematic during excavation and lagging placement. The contractor is responsible for evaluating excavation difficulties prior to construction. Where relatively clean sands (especially encountered below ground water) or difficult drilling or cobble conditions were encountered during our exploration, pilot holes performed by the contractor may be desired to further evaluate these conditions prior to the finalization of the shoring budget. It has been our experience in Los Gatos to encounter cobbles and boulders on the order of 12 inches in diameter within the sand/gravel layers. Shoring contractors should take into consideration the potential for slower production rates, and the use • of casing for drilled piers. Additionally, difficult drilling conditions should be anticipated. In addition to anticipated deflection of the shoring system, other factors such as voids created by soil sloughing, and erosion of granular layers due to perched water conditions can create adverse ground subsidence and deflections. The contractor should attempt to cut the Mixed Use Development 18005 Los Gatos Boulevard 168-2.2 Page 14 Ecl CORNERSTONE r EARTH GROUP excavation as dose to neat lines as possible; where voids are created they should be backfilled as soon as possible with sand, gravel, or grout. As previously mentioned, we recommend that a monitoring program be developed and implemented to evaluate the effects of the shoring on adjacent improvements. All sensitive improvements should be located and monitored for horizontal and vertical deflections and distress cracking based on a pre -construction survey. The monitoring frequency should be established and agree to by the project team prior to start of shoring construction. The above recommendations are for the use of the design team; the contractor in conjunction with input from the shoring designer should perform additional subsurface exploration they deem necessary to design the chosen shoring system. A California -licensed civil or structural engineer must design and be in responsible charge of the temporary shoring design. The contractor is responsible for means and methods of construction, as well as site safety, SECTION 7: FOUNDATIONS 7.1 SUMMARY OF RECOMMENDATIONS In our opinion, the proposed structures may be supported on shallow foundations provided the recommendations in the "Earthwork" section and the sections below are followed. 7.2 SEISMIC DESIGN CRITERIA We understand that the project structural design will be based on the 2007 California Building Code (CBC), which provides criteria for the seismic design of buildings in Chapter 16. The "Seismic Coefficients" used to design buildings are established based on a series of tables and figures addressing different site factors, including the soil profile in the upper 100 feet below grade and mapped spectral acceleration parameters based on distance to the controlling seismic source/fault system. Based on our borings and review of focal geology, the site is underlain by deep alluvial soils with typical SPT "N" values between 15 and 100+ blows per foot. Therefore, we have classified the site as Soil Classification C. The mapped spectra! acceleration parameters Ssand S1 were calculated using the USGS computer program Earthquake Ground Motion Parameters, Version 5.0.9, revision date October 6, 2008, based on the site coordinates presented below and the site classification. The table below lists the various factors used to determine the seismic coefficients and other parameters. Mixed Use Development 16005 Los Gatos boulevard 156.2.2 Page 15 C CORNERSTONE EARTH GROUP Table 4: CBC Site Categorization and Site Coefficients Classltication/Coefficlent Design Value Site Class C Site Latitude 37.2365° Site Longitude -121.9639° 0.2-second Period Mapped Spectral Acceleration', SS 2.339g 1-second Period Mapped Spectral Acceleration', Si • 0.836g Short-PeriodSite Coefficient — Fa 1.0 Long -Period Site Coefficient — Fv 1,3 0.2-second Period, Maximum Considered Earthquake Spectral Response Acceleration Adjusted for Site Effects - SMs 2.339g 1-second Period, Maximum Considered Earthquake Spectral Response Acceleration Adjusted for Site Effects — SM, 1.087g 0.2-second Period, Design Earthquake Spectral Response Acceleration — SDS 1.56g 1-second Period, Design Earthquake Spectral Response Acceleration — SDI 0.725g 'For Site Class B, 5 percent damped. 7.3 SHALLOW FOUNDATIONS 7.3.1 Spread Footings Spread footings should bear on natural, undisturbed soil or engineered fill, be at least 12 inches wide, and extend at least 18 inches below the lowest adjacent grade. Lowest adjacent grade Is defined as the deeper of the following:1) bottom of the adjacent interior slab -on -grade, or 2) finished exterior grade, excluding landscaping topsoil. Footings constructed to the above dimensions and in accordance with the "Earthwork" recommendations of this report are capable of supporting maximum allowable bearing pressures of 3,000 psf for dead Toads, 4,500 psf for combined dead plus live loads, and 6,000 psf for all loads including wind and seismic. These pressures are based on factors of safety of 3.0, 2.0, and 1.5 applied to the ultimate bearing pressure for dead, dead plus live, and all loads, respectively. These pressures are net values; the weight of the footing may be neglected for the portion of the footing extending below grade (typically, the full footing depth). 7.3.2 Footing Settlement Structural loads were not provided to us at the time this report was prepared; therefore, we assumed the typical loading in the following table. Mixed Use Development 16005 Los Gatos Boulevard 168.2.2 Page 18 P:7 CORNERSTONE UM EARTH GROUP Table 5: Assumed Structural Loading Foundation Area Range of Assumed Loads Interior Isolated Column Footing 300 to 400 kips Exterior Isolated Column Footing 200 to 300 kips Perimeter Strip Footing 4 to 6 kips per lineal foot Based on the above loading and the allowable bearing pressures presented above, we estimate that the total static footing settlement will be on the order of 1/2-inch, with about Ya-inch of post - construction differential settlement between adjacent foundation elements This foundation settlement assumes that the loose soils in the environmental excavation are removed and recompacted as recommended in our report. 7.3.3 Lateral Loading Lateral loads may be resisted by friction between the bottom of footing and the supporting subgrade, and also by passive pressures generated against footing sidewalls. An ultimate frictional resistance of 0.40 applied to the footing dead load, and an ultimate passive pressure based on an equivalent fluid pressure of 450 pcf may be used in design. The structural engineer should apply an appropriate factor of safety (such as 1.5) to the ultimate values above. Where footings are adjacent to landscape areas without hardscape, the upper 12 Inches of soil should be neglected when determining passive pressure capacity. 7.3.4 Spread Footing Construction Considerations Where utility lines will cross perpendicular to strip footings, the footing should be deepened to encase the utility line, providing sleeves or flexible cushions to protect the pipes from anticipated foundation settlement, or the utility lines should be backfilled to the bottom of footing with sand - cement slurry or lean concrete. Where utility lines will parallel footings and will extend below the "foundation plane of influence," an imaginary 1:1 plane projected down from the bottom edge of the footing, either the footing will need to be deepened so that the pipe is above the foundation plane of influence or the utility trench will need to be backfilled with sand -cement slurry or lean concrete within the influence zone. Sand -cement slurry used within foundation influence zones should have a minimum compressive strength of 75 psi. Footing excavations should be filled as soon as possible or be kept moist until concrete placement by regular sprinkling to prevent desiccation. It is noted that footing excavations may encounter cobbles and boulders and the sides may be irregular and require additional concrete. Forming of the excavations may be required. A Cornerstone representative should observe all footing excavations prior to placing reinforcing steel and concrete. If there is a significant schedule delay between our initial observation and concrete placement, we may need to re - observe the excavations. Mixed Use Development 16005 Los Gatos Boulevard 156-2-2 Page 17 cvE CORNERSTONE EARTH GROUP SECTION 8: CONCRETE SLABS AND PEDESTRIAN PAVEMENTS 8.1 PODIUM GARAGE SLABS -ON -GRADE Garage slabs -on -grade should be at least 5 inches thick and if constructed with minimal reinforcement intended for shrinkage control only, should have a minimum compressive strength of 3,000 psi. If the slab will have heavier reinforcing because the slab will also serve as a structural diaphragm, the compressive strength may be reduced to 2,500 psi at the structural engineer's discretion. Garage slabs should be underlain by at least 4 inches of Class 2 aggregate base or 3A-inch clean, crushed rock place and compacted in accordance with the "Compaction" section of this report. If there will be areas within the garage that are moisture sensitive, such as equipment and elevator rooms, the recommendations in the "Interior Slabs Moisture Protection Considerations" section below may be incorporated in the project design if desired. Consideration should be given to limiting the control joint spacing to a maximum of about 2 feet in each direction for each inch of concrete thickness. 8.2 INTERIOR SLABS MOISTURE PROTECTION CONSIDERATIONS The following general guidelines for concrete slab -on -grade construction where floor coverings are planned are presented for the consideration by the developer, design team, and contractor. These guidelines are based on information obtained from a variety of sources, including the American Concrete Institute (ACi) and are intended to reduce the potential for moisture -related problems causing floor covering failures, and may be supplemented as necessary based on project -specific requirements. The application of these guidelines or not will not affect the geotechnical aspects of the slab -on -grade performance. ■ Place a 10-mil vapor retarder conforming to ASTM E 1745, Class C requirements or better directly below the concrete slab; the vapor retarder should extend to the slab edges and be sealed at all seams and penetrations in accordance with manufacturer's recommendations and ASTM E 1643 requirements. A 4-inch-thick capillary break, consisting of 1/2- to a/a-inch crushed rock with less than 5 percent passing the No. 200 sieve, should be placed below the vapor retarder and consolidated in place with vibratory equipment ■ The concrete water:cement ratio should be 0.45 or less. Mid -range plasticizers may be used to increase concrete workability and facilitate pumping and placement. ■ Water should not be added after initial batching unless the slump is less than specified and/or the resulting water:cement ratio will not exceed 0.45. ■ Polishing the concrete surface with metal trowels should not be allowed versus light broom or limited trowel finishing. ■ Where floor coverings are planned, all concrete surfaces should be moist cured (kept continuously wet) for at least 7 days by soaking burlap, cotton mats, or carpet, or frequent sprinkling. The moist cure method should be placed as soon after concrete Mixed Use Development 16005 Los Gatos Boulevard 156-2.2 Page 18 1:1CORNERSTONE L. EARTH GROUP finishing as possible, while resisting surface damage. Chemical curing may be an option depending on the floor covering type. a Water vapor emission levels and concrete pH should be determined in accordance with ASTM F1869-98 and F710-98 requirements and evaluated against the floor covering manufacturer's requirements prior to installation. 8.3 EXTERIOR FLATWORK 8.3.1 Pedestrian Concrete Flatwork Exterior concrete flatwork subject to pedestrian and/or occasional light pick up loading should be at least 4 inches thick and supported on at least 4 inches of Class 2 aggregate base overlying subgrade prepared in accordance with the "Earthwork" recommendations of this report. Flatwork that will be subject to heavier or frequent vehicular loading should be designed In accordance with the recommendations in the "Vehicular Pavements" section below. To help reduce the potential for uncontrolled shrinkage cracking, adequate expansion and control joints should be included. Consideration should be given to limiting the control joint spacing to a maximum of about 2 feet In each direction for each inch of concrete thickness. Flatwork should be isolated from adjacent foundations or retaining walls except where limited sections of structural slabs are included to help span irregularities in retaining wall backfill at the transitions between at -grade and on -structure flatwork. SECTION 9: VEHICULAR PAVEMENTS 9.1 ASPHALT CONCRETE The following asphalt concrete pavement recommendations tabulated below are based on the Procedure 608 of the Caltrans Highway Design Manual, estimated traffic indicies for various pavement -loading conditions, and on a design R-value of 30. The design R-value was chosen based on the results of the laboratory testing performed on a surficial sample collected from the proposed pavement area and engineering judgment considering the variable surface conditions. Table 6: Asphalt Concrete Pavement Recommendations, Design R-value = 30 Design Traffic Index (Ti) Asphalt Concrete (inches) Class 2 . Aggregate Base* (Inches) Total Pavement Section Thickness (Inches) 4.0 2.5 4.0 6.5 4.5 2.5 5.5 8.0 5.0 3.0 5.5 8.5 5.5 3.0 7.5 10.5 6.0 3.5 7.5 11.0 6.5 4.0 8.5 12.5 altrens Class 2 aggregate base; minimum H-value of 78 Mixed Use Development 16005 Los Gatos Boulevard 156.2.2 Page 19 CORNERSTONE EARTH GROUP Frequently, the full asphalt concrete section is not constructed prior to construction traffic loading. This can result in significant loss of asphalt concrete layer life, rutting, or other pavement failures. To improve the pavement life and reduce the potential for pavement distress through construction, we recommend the full design asphalt concrete section be constructed prior to construction traffic loading. Alternatively, a higher traffic index may be chosen for the areas where construction traffic will be using the pavements.) SECTION 10: RETAINING WALLS 10.1 LATERAL EARTH PRESSURES The structural design of any site retaining wall should include resistance to lateral earth pressures that develop from the soil behind the wall, any undrained water pressure, and surcharge loads acting behind the wall, Provided a drainage system is constructed behind the wall to prevent the buildup of hydrostatic pressures as discussed in the section below, we recommend that the walls with level backfill be designed for the following pressures: Table 7: Recommended Lateral Earth Pressures Wall Condition Lateral Earth Pressure* Additional Surcharge Loads Unrestrained — Cantilever Wall 40 pcf % of vertical loads at top of wall Restrained — Braced Wall 40 pct + 8H** psf 1/2 of vertical loads at top of wall Lateral earth pressures are based on an equivalent fluid pressure for level backfill conditions * H is the distance in feet between the bottom of footing and top of retained soil Basement walls should be designed as restrained walls. If adequate drainage cannot be provided behind the wall, an additional equivalent fluid pressure of 40 pcf should be added to the values above for both restrained and unrestrained walls for the portion of the wall that will not have drainage. Damp proofing or waterproofing of the walls may be considered where moisture penetration and/or efflorescence are not desired. 10.2 WALL DRAINAGE Adequate drainage should be provided by a subdrain system behind all walls. This system should consist of a 4-inch minimum diameter perforated pipe placed near the base of the wall (perforations placed downward). The pipe should be bedded and backfilled with Class 2 Permeable Material per Caltrans Standard Specifications, latest edition. The permeable backfill should extend at least 12 inches out from the wall and to within 2 feet of outside finished grade. Alternatively, 1f2-inch to 3/4-inch crushed rock may be used in place of the Class 2 Permeable Material provided the crushed rock and pipe are enclosed in filter fabric, such as Miraff 140N or approved equivalent. The upper 2 feet of wall backlit] should consist of compacted on -site soil. The subdrain outlet should be connected to a free -draining outlet or sump. Mixed Use Development 16005 Los Gatos Boulevard 156.2-2 Page 20 CORNERSTONE LEs d EARTH GROUP Miradrain, Geotech Drainage Panels, or equivalent drainage matting can be used for wall drainage as an alternative to the Class 2 Permeable Material or drain rock backfill. Horizontal strip drains connecting to the vertical drainage matting may be used in lieu of the perforated pipe and crushed rock section. The drainage panel should be connected to the perforated pipe or horizontal drainage strip at the base of the wail, or to some other closed or through -wall system such as the TotalDrain system from AmerDrain. Miradrain panels should terminate 18 to 24 inches from final exterior grade. The Miradrain panel filter fabric should be extended over the top of and behind the panel to protect it from intrusion of the adjacent soil. 10.3 BACKPILL Where surface improvements will be located aver the retaining wall backfill, backfill placed behind the walls should be compacted to at least 95 percent relative compaction using light compaction equipment. Where no surface improvements are planned, backfill should be compacted to at feast 90 percent, if heavy compaction equipment is used, the walls should be temporarily braced. Based on the current plans, we understand that v-ditches are planned behind the retaining walls, which we highly recommend. Previously, consideration should be given to the transitions from on -grade to on -structure. Providing subslabs or other methods for reducing differential movement of flatwork or pavements across this transition should be included in the project design. 10.4 FOUNDATIONS Retaining walls may be supported on a continuous spread footing designed in accordance with the recommendations presented in the "Foundations" section of this report. SECTION 11: LIMITATIONS This report, an instrument of professional service, has been prepared for the sole use of CHL Ventures, L.P. specifically to support the design of the Mixed Use project in Los Gatos, California. The opinions, conclusions, and recommendations presented in this report have been formulated in accordance with accepted geotechnical engineering practices that exist in Northern California at the time this report was prepared. No warranty, expressed or implied, is made or should be inferred. Recommendations in this report are based upon the soil and ground water conditions encountered during our subsurface exploration. If variations or unsuitable conditions are encountered during construction, Cornerstone must be contacted to provide supplemental recommendations, as needed. CHL Ventures L.P. may have provided Cornerstone with plans, reports and other documents prepared by others. CHL Ventures L.P. understands that Cornerstone reviewed and relied on the information presented in these documents and cannot be responsible for their accuracy. Mixed Use Development 16005 Los Gatos Boulevard 156.2-2 Page 21 INITIAL STUDY -16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD ATTACHMENT 5 PRELIMINARY LEED AND GREENPOINT CHECKLISTS (PRE -CERTIFICATION ESTIMATES) a Possible Points: 26 N N 22 1!! P P Y Y r Possible Points: Indoor Environmental Quality :a 1 a 7g 81 a 2g LA u 4 U e V. w a N m R Q o ag z°3tE 8 E cU n'aE i a3 y u° �^ J b c` a c o a CO a a a > m S N a c as nt at.a0 c FPPPF Yv i 'Li�� r$� E C J (pp N 'I u_ 'j�u�j u TQy! O C Do pl I ii 4L V O N u s {� G. 6 d nj du a ec4 em- .' .4,2 Yw mCO4' :L �ntn�nv��n a 2 asg g g 'mC C C C p S, 6 G>� I I A.,* e e c o .CD L1 O' dCU a a a c vi of .x . tl0 em a .gk a1zg gUM" 2 °» Logo C coy o o c c c E z. E 5 v �i c c z c EEa B��_;lira,ymm aEE, ,Q 0 coccv ° b o o g a �d Ca L b b : G °c c �i�, i W O C U U J J J S V 'C L O O ::0• C C JC C J 11yy �. N Ni A M O R f T N V .tj n N m' to :. o N en `f in N P u9 Y ,O P N1 N u E 8' a m. C w U� a _ > w C W ro C C t�0 a0 Va"8 ✓ v L° ,° 'ti a e u a w c e C 0 n. E a 16 a ram. n a m a 73 o v °' i° EI- V V 0 iy' d' 8 8 '4 �-6 8.8.8.E „, TT • gt• = .I-I-'- no,m�ww ▪ 3i ru E E E E c o EE L441,1 C«>, CO a a a a a 0 0 ep eE N en r mi f w YI Ill •O A n ro 0 Possibte_Points: Water Efficiency O O N N N 8 8 $ 8" e g11.4 36 a t 3 ez 24E,!JI.N ttgl 3 3 3 Possible Points: 35 • Energy and Atmosphere IgAggg i-+ a, a Regional Priority Cr V N N m N r P P • b u b u u =u u �c a c.c t aa00..a C C 0 CITVVV N 111 Material h N N O BB P P P Y GreenPoint Rated Checklist: Single Family rflo GreenPoint Rased checklist becks green foaluioo incorporated Into the Nana. A home le only Groan Point Rated R ell features are verified by a Codified GroenPolnt Rater through Build It Orson, GroanPo!nl Rated la provided as a. p.?NiC aasaco by Build It Groan, n professional ncn•ptoSt vdsoso misdeal Is to promote hay, energy and roman alfrentbulki:•+gsin Cafanis. Tirs overrun ra tarenua!s of GrcanPo.M Rolad are as Mow vankeaicn of 50 no more pants' Earn rho tdknvosg Total Pointe Achlllvet 148 35 GreenPnintfATED . roirim rn points per cMa;a(k y. Energy (30), Indoor Air mSryMoalh (5), Resources (6), and Wolof (0); and meet rho Piaoaui,ile1A.3.a (50%calc0ua'co waste dive:do:n), 3:1(Exceed Tille 24 by 15! ), end N.1(limpet eta Green Prim Relod Cneek.at in b uelxgU*). Thncriteria Ica lhogreen bad b;gpracticeslistedbe!vlvarodescribedfntheGreenPanl[totedSingleFam!lyRiding Manual, For mom Information plume visit www.bulldllgroon.orglgroenpolnlralod Singio Featly Haw ludo 3.7 e rtter Project Name r r >il s. k' Cammank( 'i w �• T 34 ' "1 - 5 a itSINIMP W...�.....,..._ ) g oe 25 3 ,. itrdta ,,. ..,2 z-, ., fs A.SrrE .,`-`r'. ',,*'. o'1s .1_ 1- -- .ors r -s, ?,: tt^ fan i„�'0G 1, Protect Topsoil Ind h5nimlu Disruption a Existing Santa 8 Trees Yosa Protect Tcprnf from 6oaian and Rouse a!ta Ccnseuceon ... 7...... x..... ........ ....... ........_ j.._. ...•............,,...,••,». ••.,.•.w_.,....,...•...............,...••,...,.,.._..._.„•,„ No b.Unit and Da8,eaa Ceostution Footprint farllarmumr PmlOuion o ,....... ' 1 No 2 Deconstruct indeed of De mdiahAEaistbtp Buildings On 011 0 :S 3. Recycle Job Site Construction West/ (Including Green Waste) aEkor,rn5r14 Waste Cia7co by Weight (Rocyuloyo Reuse)• feepanrd .,...6 ..........................._........._........_...............,.....,..:........................._.__._.._...................._..._._._ .......,µ..............W�. „. Yes Yos. b: Wirral' 65% MYE/d011byW6aju (Recyd319or R(4ie) a Vainest 6Pbaverslon by Wei t R 6h orOl'r o .... .._... 2 .......«..__.....-.... _..,... ... ., .... .......^..,._••.••••.,, .• ......._... - Vas 4. the Recycled Content Aggregate (Minimum 25%) Yesa: Wrilanay rrd Drhowey Rua ..._�... ...._._:....... !......;.... 3......j...........................,,...•..,____.._._______...._.__..,_._,..,,,..._ Yes bRoadway Dace 1 i : Y I µW._...... 12 D pp ��^^/r..a, ryry,alca,r4,PRaerinteAvalab'alnSae ���,,,, FPAPAlO'N . 3s.,.�c'>xdf Ymn.. si. ., .. x• -. . 31 4 c. •7� ice• h- f a# - S�'.r...-:f�.,�,gz, - !:'.P, ��e itrI.bs i 6.t` 7t'�.-�f��QY::�ta�Q -�� �a,^�(i, �a �. �;s� ,A✓. ..a,.: l:t� 1, Replace PordaM Cement In Concrete wah Recycled flyaah or Slag y Yos a. lAtsmam20X Fyashor Nag t„ �,.�,,W.... .........i ..... ..-...:� -Yes:i b. Madrx,m25%Flusher Stag,_.ww.„._..„,._---.......„_.._.... t No. ills' FrostProtected 6hetlow foundation In Cold Aroee jo.£.C. Cllrnate zone raj (. Die Radon Reslitan1ConsfrucUon D�.............._µ•••_,„_..,_,. 0 _...___._ ......3.•„„• ..,,..,•.... ;..•„,.,_.•,...„„,_," ,_,_,_, ,,,_._„,__ fie , C@wtlaiI !drr#e.Rems.zdl tslaltt?itt14..Jttes0J1f5a65U.9t<.--,..u..,....,,., ,...,..,,,.»,._.,. 4; O,aign and guild Structural Pest Conbalr aInstalTermite Shields 8Soper ate Ali Exterior WeoataCcnaole Cmnocrbstn lay Mehra Pla0o. i 1 ? No Fastale,' 6,"ders 0 C1 nle.pvramose!eeaelli4.'r1?snP.Cieltmssfs93!err1res g.:17L55xa15A0L.,.W,..........._.»........,,_......,. _ b./AWlerw Plat% lure Tttmk,Oase,orStem Located Ai Least 36 Inches from fowdalkn ........ ..................<..._.__.........................................................._._—_ Yea foldPealsAvald.om famda+on 8 3 /, ,'.1a... L AND fll(GW7.L .t ;.3 Wi_, .i t... 3 :_ e,1 ....Jig:. :�i. ,.. . ':_t� j i i ":-tTL^4�ln'uo(eblo. Mate"....,1..x.}' i .,,»,S' 1. Construct Resoureo•Efficlent Landscapes Yoa- a No IreanoSpoda Nand byCal,IPGN0 Planted 1 1s"a b. No. Finn( SpciasWIN.4.•e Nad$n9 o... ....... ..:....._._. .F_.......,`.....;!,.....'...._.._....._..._.......,,.,......,:...,•,,...,................_.....,...._..»..w...,..».,._...�. c75%el Plan:sAre Caalarda Maw oruch:1u,, Spedoo or 0 fief Appropriate Suedes Yes. 3 Yee 2.UseFfre•Ref etends capingTxhnlgues ,,y«»•„»�,,,_,,,•,•,__, { .t ._.�..._�. a. tAmmire TudAreas in Landscape IneWIk4 by OWIQer f... _.. __._.___..•-,-. ......._..... _.....__._.. ................ _ ,.„-. ;......_...._.___ ..._.._____ No a ASTurlYta RaveaWaarRegire,•err?tteal than orEodaltoTalk-scud (caOAdmll(Wm) 0 ': l Yes It TwMShu, del eoI:eddied on Sieges Exrnodag10% or in Arum Lora Elan a Feet Ma ..,2. i, .. ._ ... '..... .._.. ,__.„„.„..>,,,.,..,,,„ ••••..,,..•...«._.M.r„.,__,...»...�•..... tint aTurl is 533%d1.a^4xcpM Ante {Fetal 2pdMn) .,,.-, _,.0 ....,.,_.„,._..._,...•....:.i.,.....,,»,_:::,,.,,....,.,.,�.... ?..._...:_ �. ... ,..,..,.,.,,„N._«.._....„.,...,...,............••...man,,. No u.iedis410%ofLadrorradAreaebe4pdeua) 0 - 2 Yes : 4, Pant Shade Trees fie: . &GroupManta byWetarNeedtgotloxonf0gj &Install Illgh•ElRdancy irrigation Systems ® a.SytomUses Only tow -Flow Nip,flult'ora,orLow•todSprinklers 2 > „„.,„.,..,...__ MEM b. Siam Iles (kart lweada•oaset�Cpnuolbra 0 ® - T. bar red+ Two Inches of Compost In the Top a fa t2 Inches of Sap ® • ,µ& Vuiah All Planting Beds to the O,atar of 2)nrhet or Loal Water Ordinance Requirement 0 .,, ?. ,_, ,_,,,.,,,_,,,, m_,,,,,•,,, ,:` ? .�„ ,,,, ,,.. ®�t� Um 9. Use 50% Salvaged or Recycled -Content' Materiels for 56Ye of Ron•Piant landscape Etomenhs 0 10. Reduce I1,oht P olhlt„onby Shielding Fixtures end Directing U8ht Downward;,•••w,„„•, ,,,�,,,,,• •••,,,,,i Pan a Avara,sin landxrph9-31 0 3 '.' r�Told 1�,a 1,Ik.M.l`!.ILAL.FM.i 1J)LDIt7_G..M,e.1.F M.[iLR:_.. 3?«-}•��,_Y....... .........._.-.L ":,,.:�L_.....,�'4,e..t ,z ,»..•. p,,,�(�A)�,.,, p/,/f 6 food f`?.f a6L:11- 1.>ei ' Y ..-- f t„ 2k l :a•-, 1,APMTOpUmilVWW1 Engineering 4..................,...,..-..,.••--...-,.__,_.,... .._..�..,m..__,.._...._.. ._..__... ... _..... ..._.___. Yos'' a;Iwo Briton and Studs at 2l-Inch On Cantor Framing i ........f :.............i1•...!......_.,.... - _,_._._. ...,_._Y____...__._._..._...... Yoe.'. b. Slto °wend WNAow Headers for Load ,.1 .: ......... i. s T 1 ......_.., Yes o. UsoOrd•/Jakand Cn0jfo Sluda00lu!rad for tontt .„, 2 Use Engineered. (.umber a (dams and Udders b. Imolafud Enituoced Roa1esa 1 L r .S, s - 1- _.. tk Yd.', o.Wood lJdslaorWeb Trusses far Fkcrc .....! ....: .............. ? .... ....,,.,.._...„,..._,..__.._...•r.,...........,._..„,.,..,,,...._.__. No d.Wood IJoistsfor Roof Rafters t) ' ....... _.)...................... •.�..»,„..•._.�,._.,,..___,.„ No. aEngoaaalaFinger-Jointed Shale for Vort't lAppkatees p . ..:......„ !..._...... ! 1. . .. No: - I Ofmn ad Strand Board fa Sub'oor 0 _ L y0' 0oI Shand goaxller tedam1Rxhorfh! i Sn9.....«_._...,, ... ,,, . ..,,.,..,.. a. Use Ufted Wood f6C.Cer -,.. ,....„.._..• 1. i _. _,_,_,__,__,„.____._,_,,.. NO.... Yes a:D'm+,sdonel tenter, Shade and Tinto,. Mann40% ....2..._ ,,.,, a i Yes b.l)rswnsmalurbu, Sake and Terbx; M6oru rn 70'fi ,.2 .. ? ... _......_........__._ __ ._ _..._._.___._.,� fkr ' a Pant 5,akets; .4ximsm 40# .. D .. .. _: 1 .........._ „„......••,•..,•,.,•...•,. _..„.,......_, .. ____ Na..........._d Parn11Pa,tars..lF?rirrcan TO%....,_•...,....»,,...._.«....,...,,.w._...«.•.,,..., .............„. 0 ...,,...,._..•_..,..�,._....,.,.._.... f . t Build II Green SF Data Collection Form v.3.7 Page 1 et G yi rater 3. Prof c Name kt 4. Use Solid Wail Systeme(Includes SIP*, ICE,. 5 Airy Nor Stlek Frame Assembly} a Pons b.SYnila...............,_....._...,...,"_,._....._._�,_._.._... a Roots 9 tl b F 0 ............ L_._... f e c z .- el ........--.....—..—._..._....�.._.._...._.._....,, M z _........, » x it . NO No- ._.....W......w..,„_.,__., S: Reduce Mullen Entering the tlones (rnmthe Garage I'Pdntsa;#r,m ecaDvvotedAltonmtecot*ArmalamiasmaJ3.ESwith1A2I 's, Tightly Sad Mak&vela lot+xm Ocoee) ani Living Ansa h. Instal tiaapExhaust Fan gRD+sllnDolathadGaFae _.�._..._.._ ..,,� YO3, ( ? ._.1 ......_._..._____........_ Yea- Yies es Oeel Ene Heals on Trusses 5%ofAttle insulation Height et 0ut Ida Edge of Exterior Wag) ? 1 a Yea: 7Design Roof Trusses la Aceommadida Ductwork 1 - 1 do flecieled•Contant,D191 Studelciles ciletterle!yel Feeming D >....W." } fro _Jive RThermel Ftne YNlls VilAk Orywel(on,AglnUdotWalN otWdls V641*Nmnre tlnn rig lbku.R 1 p 1 10 M+WI Werhargs and Cotten i a 6(rd;mun 184nch Overhangs and Guitars ('Polnlstulamaticaty gamed when pro(ocl mudirws lorraawra J3t ES eith IA0) 0 t EMI b. grimes 24dndlOvehangs and Goiters p Tdat Pen%AvaithbM SNacant&Adel Excess and E)veloce a 34 12 go. (,�E'�(i�}j�T1 �"''�£ .x, ..a.��.-� _._ _..�x,. ;i iftxozi[sAvailal3oPnetloasuro� Nos1.U+e Re9cledGentant Rio Virgin Plastic)or FSC-Certi0ed Wood Decking 2 2 , ® 31ns4l a Rein ScreenINAA System 0 2 am 3, Use Durable and Neo-CombuuUbla Siding Materiels 0 1 4.00 Durable and Non•CombuuuWe Roofing Matedafs i 0 "+ ' Tdtafromsn MalaYeExteriorfrah 7 2 F,if ..'hark: iit3111 .. ar'$ y ._i?, 1. Install Insulation with 15%Recycled Content n SrsaePnr! sue' a'" ,- r.,?.,y , Yea a Welk and Flours i h....._. Yes ...1. w 0 Cotird.. ..._...._................................ ._ ...... ....._l ! i IrutUS Insulation that le taw•En6Uing (Cedlfied Seeaon 01359) .. _._......._...._.._......._ _ ,...w....,..... ,w.....,w., ........!..,,,a.. ._.... . a Wals earl Moms D _........ } ......._........_..._...«. t33 : .. _ _,., '-- 3 Ins eat Quality oflnsulaiion Mstellatlon helaeApplying Drywall ( ,rPoetts Yes automaficntygatod%tsxm Dra;fdpa<3es for mama J3; ES with 1A0) l 1 ? , Told kills AvsEd5a in iristaadon a 5 1 3 .Ts.;,KD IN - `'1i� ,m,. .. PointsA0 14btoiSdtManutou.-.a a , e,012 2.4._..m. .......v_;r..',„"-__...;:i:;. ,.Mi..;,_.....x.;t .,,..,m 1, Dlefrlbute Domestic Hot Waist Efficiently (Additive, Maximum 7 Pointe) i•— ,u, ' Yeti a.!nubile Hot Water P}ar from Wales Heaterlo 0ikhen i 2 `.. t Yon- b: MwimeNI HolWatetRe a Im.,,..,..._..» ..............;.,_._.,.............,....._ ..:..,._.... 1 _..._....,_...,..,,......._.......,....._...,....._.._.... 52' o UM Eryins mud Para0eliKprg..........................;...............#................,.................L......1.......,.._._.�—._... 5o d Um E58nemed Pratte ffitieigwidt Demand Corimied Cira4ateu Lcnp =, . D o. UseSMa4memd P}an00ig Min Damand CCe7Uted Gtadatvn l oop r 0 Use GanacCoPAxr27ry _ p tra ? -,.,.....w._......w...._.d..„,..,.,,.,....,_....._. 11: I . ,. .... ................ .._-...,--.«...,..�....._....,___._.....,.... Yon. Menial] Only Hlgh Efficiency Tellers,(Owl•Fiush or 5123 gp1) I 4 Toed PoglshvaIMMta Plum a To1N 11 id 112.1.. aG I33,11' 1121 `MAIM. NIKAY it 1 Pis)' 16lseige1�i2PWMeaoliittiA eY, r;. ..:,-1a ,aa h _ i El i 0a11Sn and Install WAG System W ACCA Ma noel J D and S Recommendations Meets mimeo* gmod Mum prgnctgoatees for measure J36S whit lAgJ.... ..... .........._.................,.......i a,_...,m,..,....._.._._i_......._,..__.._....._._„__...r._.._............_..............._........,........._.,._.................,....... .,,...._.............._.,..w..... W.m_.,......,,:,......_.._._...,......,,..,.,..,,.,..___,......,,..._.._...._,...._ if 1 2.Imta1i Soalcd.Combuatlon at. i t'Pointa sauterne& waled xtnn Wad mates for meaaso J3: ES wiyt IAO1 Yew. a.Pummel 2 .- i......:...._z_...._.,m.._i........,..... Yon, .. b,lYatrs.Hoalms e- 7 ! Idea- 3.Ins052nncd,HydnudeRadiant Rating 0 A i 4. Install High EfiwkncyAlr Cmtd'dioning with Environmentally Reaponsibio Re5Hgerente € p t _.........6,,.Dealien end In MilE_e._.._.0u,w0.,.,w........"......................................,..,.._...,......__........__........_._.........,...,.«....,..,....................__-'—;_.._.,..,....._........M;......,......_............w.....,....._...„.....,..,..,..,...._..,....,..._._....._....-., 5, Daelgmrhd Imtal) Effective Ductwork ..�������� Per` .d.&a We au:0113 caAM rOM?6dsehen aaal audifes for measure J3-. ES with IA0i a. Incla4HYAC Unlud Ductwontwidhn Ccev4fiunotl Spew b. Ura Crud Mastic mAl Dud JdntS and Souris Yt1A • Yon .- Yon a. Insist 0vxrwakmidst Aida lnwie50n1Uuead guars) i 1 ti.Pinsuiro Remo Me Dt%hlurk System a Pratat(Ahds darn Gcnatrixixh arvlCWmA90.cis before ga'y>rc'1...,_......... ........ 'Mh 1 : ' ...._..__ Mo. Yos.` Y- S.ImUS High Efficiency Hos ('Wntawicmedcaly 7aMedwhanpqul quii[va for msun uJ3: ES Anti MR 1 _..... ..........,_"_...�_ T.Don't Install Fireplaces or Install Sealed Gas Fireplaces with Efficiency Rating NOT Lass Than 69%using YBn. CSASlanderd+ t _ Ainstall Et/active Exheust Systema In Bathrooms and Kitchens leta5a am oulorreDialy monied when paint Qualifies for measure J3: ES wen IAQI a.inuaU ENERGY STAR DYmWaled a4la the Outside „ Yem Ye6. b,A4Bathroom Fens Ara on Timnro Him slat 1. YQ9 aInthe10dunRarguHoalNnbliroda,9'414e 1 a ImtaH MechanicalWntlUUan Syslam for Coaling (Max, 4 Poinb! '(elm a 1OI1I ENERGY STAR eating Cam &Ughl las in Wes/Vans &findroams 1 I t i i - - ib b, inslatAtde Hams Fanwiyi Weida Spaeaz ? o i tb0 0Aahm+aud'' y Cu.NJ1`kd IMaryroad Syolom } 0 x . 1io d.kutxnsiceiy Coneeitadlmo5a'od5 stun cies YainUe Scend Coma D ..,.. _.. - a x........" _._....„ .............".. . �..__.q.._. _,,,, , .._._._-..._...___._._ 1a.Inatall Mechanical freak Air Vanu4opnn6ystem(Maximum 3 Pointe) ...... __. .....,..,.,,_.._., w,......._,......,,..,,.,,,._ No a.Any %bok Reuse YenteaconSysem That MoatsASHRAE 62.2 b.InstatAk•taNr Noel Exehanparthat monisASHRAE622 .. 0 .._......... �':.,_.,...,.... i - - .,•.^.. } --..--....__._._._....�..—_._._..... Na_ I'Pa'nts automat'oah'y granted when prfom gualdas lormeacvo J3 CS w0hlA0l 0 1k1 ,... . .,..,.w... 11.!Wall Gerhart Monoxide Marmie) 0 __ _ _ 4 ] . .._.... ..._ ...... ...._...... _.... ._.. �.....,._.__. ('PoimsmtcmaSdty panted when Repel qu1Fasfor manzon J3. ES with b10,1 Tad Points t+rain%M Homing. 4Wnteet'en and Air Ccrd:drxiM j331 . 19 5110611d It Groan SF Osta Collec1on Fort v.3.7 Page 2 of 0 Enter Project Name g» - tN° `A a 4 ARER-li%lYa.+'.d_r n„•, ;'.-$2..e"•- t $t,y i_ ax,2 `f T } -- ¢ 3 YalTAY4Ilatli13, ru F 5 71 q� a Hda3Uf0 o 7,T' r t. 7Tot0s 3 ilq, 4 1E21„M ' EMI 1,Pm•Plumb for Solar Hot%War Heating 0 ..2, moan Solar Wafer Heating byearn «...�.,....._..,..._..._ .., i 0 3,Install Wiring Conduit for Future Photovoltaic InsUlUNon & Provide 200 It' of 6outh•Fecing Roof 1 0 4 I l0 1,,....».._....»,........-L.— ................................_.. 2 i ..,,._..........._.._._......_...____.__._.._ ..... e:Imtall Ffiotovo7Wk )PV) Panels r a51Ke4 n'ddrie Hoods OR 12 kW (fuaI6 &toU) i b. 10% cfd'ecbc nemis0R 24LY7{kld 12pcints) r 0.50%ofabccbrood OR3.BLWJt01at 1 nls) b No tl tl - fi..l..............e..,__......._. ....„_..... 6 NO .....__._.,......._ _ No. 0 ., TccdAvalablo Pons M Renpwabla Enotgy 0 28 0 ..KIKI1AUEAIi iggk. iTN# ; ..,. , z,ir,r,..,a._ 4., ,, 1-2-ii. :1A ,.,.u„ f. Dlagnoadc Evaluations a (loco Panne 010Att Ma Rol I )'Pointsautann7c0lygmiroJwhOnproscttrpm2fostttrronsonsJ3:41w0.IA0) b Haan Pasxs Carbuston Swot R.ackdrail Toot . .,-P tIcAP �P P ti ut6 _ Y02. 1 1 .' .. 30 f ... ......... ......... .... 1 ......_...._'....... • 230 ,...,....._,....._,, _..._..»...,....___ .»_..,,._._..,..»...,...._... 1511 2. Design and Budd High Performance Homes •15% above 2005 TItie 24• Rectum . 3. House Obtains ENERGY STAR with Indoor Air Package Codification • Illor Moat oro (Total 41 Onto; road ) 0 4omMA•__. L „ 2. lord AvalabDPun0inildhingpa,onnaxa 39 : 32, ®i -4 , zs ;r s t:xz t .t '4 lza..a L _ , V 0 2 0 1 1 _, 1 L. g 0 ..._ , n.�LAY aEda ar ;?.µ . • 2 1 - ,....,i.�S.._.,..i,._._..... ... ..... ;.._ :L_._ .-.,s.... ....,..i... 1 (o s(e 1 d i x.a i , k r i#a�, _ : _ .„i. 0osign Entrim to Wino Tracked In Contaminant. ,,..,.. ...... .. „ ..,.,.. ,) 1. Use I.ow•VOC or Zeto•VOC Paint (Maximum 3 Points) alow•VOC InteriorWOiCalilg Prints `04p0VOCs(Finl) & 44000pIVOCd(Non•Plat)) I b 7,dro•VOC:Interfa WadiCe0n0panlatSypIVOCs(Flal).....,„,,.._.,....,»m......,...,.._...._........ 3, Use loot VOC,WaferW+ed Wood FInIthas(a25oHi VOCo)... 4,Use low•VOC Caulkand ConaWotton Adhesives 4g VOCa for AllAdhotWee ' B. Uw t Pe Recysied•Conlanen! ,i 6, Use EnvironmenUgy Preferable fistulae for Interior Finish; A) PSC•Certifed Wood, 0) Reolemed, C) Rapidly Renewable, 0)Recyded.Contant or E) FingerJo(nted aCah:asU (50%l4inkntun) b. 0Maia4dm(50X Mi0orn) . 0Sh0+ing{60%kffeemin) d. Doors (50% 0An0nnm) Cou0 erWls•(SOM Minims;ml......................._...._..:,...,,...,. 1 7, Reduce Formaldehyde to Interior Finish (CA Section 01350) a. Sob(na&Staff/Tieads(90%M Mum) i:....>,. b.Ca0*ola &Cosmitlops(40%14:'nbnum) s..._1.-> o, losedit Tr'in00% fikimu1l) t d. Sha&4 %Mt vrun 8, Alter Installation cf Flnithas, Yost of Indoor Air Shows Ponnaidehyde tool 427ppb ( ._.._...._.».._........ • Yes ldo - Yoe ..:.........._... .,_...,.µ ..........,.. Yea N0 - 1. T f. € t ............ Y01 Yoe ...._.._..,......,_..__..._...�.____..._..,__... _.................»........w..,.,.........»...,__....._,.....,............_. Yoe- Yon Noa. . Year Yes`:' �....«.,.,..,.,........ :............._.. N0 N6: Told &YaaebePeels lo Mhos o 21 12 € o..sr, a {.;:'%gi311:6tip: s(1,.__, _ ._ltgz , ,,,, W_.�. ,•.„.-- v,..• .�: _,,, iiir r_'rye,ednlc�in'1'aWGRXr,Maa3,fntW;T':.-' .thtGir3 s-iiiit,.... 1,Ute Environmentally Profitable Flobnng;A)FSC-COn1Rad Wood, S) Reclaimed of Refinished, 6) Rapidly ( Ranewsble,01Recvoled•Conlen7 El booted Console. Hoofing Adhesives Mar (logo 4100nl VOOe, a.Minmut15%ofRoofNoe j._ b.MiNrrum 30% clfkorAran a Mkdmtan 600% 01 Mork -ea 4..Argrosn15%of Floor Area 2Thermal Miss Floor Covarin001hat0an.Carpnt on50% of 1dore of Commis Flans I„,,,•_.......__..._._.....,,..,..._._._.... ,iv a. _C.:... 0 0 , D • .._ _.._ _........... ..........._.,......... 'i .....,.„._.».»:....__..» ' ' ,_ ......,, 1... . ..._ _..;. ,L 3. . i . i Mtaeea•��e .................,.....,.,,„,,.«.,.,„,.—...W,,,.. ..-- No No. N0 No .. .....,,..,.,....,.._.,.,............_,,......_.,..,„„,,...:.... : 7t0 - 3. Fbaing CRI Label Plus Requirements (E0% Minimum) _._...._)'Pints adanalcavoo�,yr,ontod 020,0koo0tAyalwslun• suet J3: ESe.Nr1A µM.._...._.._._......_..................3..,......_.........___i:....._,,,.:_.__....._.._...__.........,...._, Tot0Ava7abl0 P0411,114 Flxa( 1 P.I A RH kid ` :,, sic `.Pit fi, 3. '0 .,a, 1( y.,.. ? 4 ,4st 7 is pofni. iya(ata . r 1, Install Water and Enorgy Efficient Gishwsther a. ENERGY STAR Hold I ponll •.,..b,(Maratha( Mos No Mama1._5Gdkn.�?,01ldld2 i'ti51....._.........,_.........,_........,„...._...........»»�_...>,m-U 2.nU_ENERGYS_AR_Iothe*Wiuhn4Medlin* wtJ_WAlar Factor of 4 or Lass & Meets Erargy Star aryl CEE Tie 2tapltenorda(modO4i°a,y factor 2.0.WaM0r Factor 6.0 or sou) b.T4a*U&NV SW and CEE Tiara towFiera'uato(mdItiod mug? la0a 22.Wdwr Facts 4.6 or !ow 3, instsg ENERGY STAR Refngent011 I a ENERGY STAR Ou6Aad& 425Gaffe foot Croadty 6. ENERGY STAR 0rnx5Rad0 ‹ 20 Cutrn Poet C nd 4.In W li Builb(n Recycling Confer and Canpo*tang Center aE07idnRarydingCanter b. Euilin CompostCantor _.. I j,,,w•• 0 ...., .. .1 .„. ., ,..... ... 1 �_.. 2 _._.. .... _,............,.,..., ..... ....................... _ Yo0 No .,..._.,,.._.....__.»._..,......_....,..,,.._ . YamRaga tr.. Y04 0 0 _.... i 0 . 1 _..„.�.(„.»�.., r , j ..ido I., 2 . (26 his ToldAvai7le Pants in Ap T*'.*lamd II to 12 y 5 e ;� 4t� � d : y � A.t: la'ft e "( . apolh(gAo*o iflorjfnoWm �,.....' ._, 1 Ineotpevale GteenPdGW nt Rated Checldlstin eptts Nagvfrod ,,, ,, ,,,, D,«. 2. Develop Humane Miotal of Otto Foatutcti0en44U 3 r. Pr1ots aufanatbattyr mlod whoa torr4 g4aaS famaasan AESei0IA0) ,_.,_,_ n . II,.d_„ 1 } 1 , 3: . TotalAvc7a14o Points in City 3 7 ..„.&„.„ ,�.,�2Ef�,U�d(1Y..9��1�11w&PI,At�N1N.�2<t�D,�(!i�[n.�a�Itl;�tt)L�..�4.�4i�tt}...�.�...:.� IAMINTe^^.' FL ..t pT...,kl*Y ""f „�,s ...,r,,..._ f, Developineil SHas. ' & Prgddls Locator InoDui Whoa Solting with Utiibea In Need rot ()goon Vora b.Orrrebpmentis tocato0 within 1t2 Min of a WO Trardt Stop _.....,. ;' PC1n(nAlfekll p i,IA3a5�(g : ....�i�; a'Ui ttt fit +d i r��M�_„�._..��_._..��. ..._ 2 1 Yes- 0 Build It Green SF Data, Collection Form v,3.7 Page 3 of 6 P�rpa��jaax�axaa{�i}y� ntea �i ['/��a ppa`� yyaaq�y�� a roject NQlal� 4 S t i 3 t ,�, = 4, .:. .. ,. _h, ,;,C•. ,-.f.l .ti, �,_ ��i 7,dudes Homeit5KldpSlztInCheek a Chssfvttortps for Land Pros,Nakn ( b. Conserve Resaumeabylncmaaiag0<..n:Jry(1ptkrovary 5ulagnsduShad 10da) Enka(0rraaiDeesnytin Oat ParAaal a Horne Sfto EfCrdorc 1 .w..............._._........,......._,,.._...._.....,._..._., q t: $$ c� i q8 j .,,,.w,....�.._,...__... ..... .,... 1 E6 Ra _.....,_...,.,P..,.u..,...,_._.............,.,,,_._. €� 0 T.«.....,,..a..:...,.,,,.,...,.,a.,w.,«..«,,...,.«.., f 3 ...." f...-:.__.__..__--»...._...........__....__,,.._,..__..._.___...__...___............_....,...._.._..___..._.._.........m.......,..... 2- 3 ) ' 2 ® _• ••••,,. «.« _ ...,...-.....-...,,,. _ 3, Subdivision Wool a Orientation to Improve Natural Cooling and Passivo Solar Attributes • 4. Design for Walking&Bicycling a. Pe3a4LianAwes lo Neighborhood Serrcesniddn SiMk 1)Community Cauwf!;taary, 2) G•ow,y WO; 3) Snod; 4) DayCae; 5) Lewdly; 6) Med1cal; 7) EEtoddlnwnVReslaarradla; 8) Post Olgca; 9) Plow of Worai2p; 10) Bank; Emu raun00u elsor 0ua c,AlLout % oafUnFd,H;ingTraYwCdmrgSua;o as: -Dosivolad f2ey 00 Lanes an Proton( on Roeienye b. Devekornanl Is Ccmcetad all ACedicalod Pedsstdan Pathway to Planes of Roaeafcnd inlutestwitbk 1P2 oat,II TenFoo(Masa Trees Lenox -SimetCmstingnCbns( to Situ ao Looted Les; RIM3OSFiwt,t{n ._.,Simotal7Tsi. StlaSkiaa,,a2Suds,SsiaodCm:awaikaa3iiMunT.ldanda_. Y6s 1 q ( ( t Z i .............o..,, ....�.,.,.,..„_.w.w�.._„,...._,«,_.... - _._____.._._.;.,._.....,..._...._.._ 5,&sign for Safety a Soots{ Gathering al3 limo Fmnl Entranaas Have WM WTI VA Gaddy to Dut4adn Cn!hsrs b,AIHOMOFtOMFulbsnoonCmboSoonfromtheSkeatmsibrbanOherFrcolDWrs aWentfor Oh;;ante H,fssholdt oats and Pubs Bya✓sss................._...............................,...._.....,,,......_,..._..,..........,.,...!>,,,...:,,..._)::......,.«.,..«..__.„..w._m»».,.,_...._......,.,«,:____....._....,-,.,,,,.,_,_,,.,_..,.,.,,,...._..„_ a Deign for BWene flawahald4 a M Henoa Hera a! Least Onu Zuto-Slep Enbanaa i Is. All Main Rot Willa* Want Pasaagoaays Wm, aMin+num 32-I ngroan Paraago Spa:o ; a saws atLoaat alidFDa1t on the Grourd Floor Kith Blocking fn Wdla far Grab MIi it. Prcvvkle Fui.Fincdun in'..e{wndant RonidU --WI Yoe . f 1 0 •• 9 i 0 16 '. Y 1 f., •w. •_.,M-,•„•, t : T m ......................,...._........_..._........._._.....__.._.._...,....._._.... Tdi ..... No- ......,.^.-._........_._ -YaC' Yee IActrrvaa»Po108 Connsn rDeomaPWrNng 20 P; INNOVA'�14 StI[ )118oi. .--' - itt] iflis don) 9 ..Pe tdi drts� rc = _ A,Sita 1. Radom Haat-Hart Effoot•Insia4(lghtmkmd,. NO abrdoma:rrlds(SMar ro:'lactaroasndaa >�0.3) for al toast �6, of Sldanmdmlineo14 son(ama ZStildotDe tratttibraat0:dd44 i ...,^ .^ -,..,,._... ` Yon _._ ..._.._. _ ..N0 ( 0 3 B foundadon PPOintwautanagoall2otonledwhan pdoct ova 5fenfoaMono J3: ESe24 IA01mem ` llnsldtuiaildafonOtcamgoSyobun Seded and Mature C rga llxd GaMson.4 C. tandsupinp ....w.., ..1 1, Gloats .Pdo:d LarWew Pavan not rrsrara! r ninOne idr PC 2 ( Y Y ( �,a 2.McHSCMSfallo-Priendyt.anlceopzProgramRca2Eromont 3.RdnWhier ttxv»s;nq Systm(I peintfor c350 ga5eng.2pints tor r350 peons) aWas Stan 350gn00oenaa`ity ! b. Credar than Sal galm ca€+uity 4,Assoss SPA Cfmam,G ono,T h, and Dtairw Ps. of�+a3aap Y ge )...,,...._ 5, Won a SoilAndyss 6. inigatbn Syctom Urns RucydodWasiow0ton ^ 7;FSC Car(tlW, Rbcydad Plnslia nr Carlo Lumbar. Fad:.n4i:7Gh»,.W,....,.,..._,...,..,.,.............._,..._,,......,,....__..._..._._.....,._.....-__.,.....?,._...,.;.... D,SNxWni Frame and Building BnVolape 1. Dadgn; luiki and lidnt0n SYICNra1 Post end Rot Controls I e tccaMA008k (SkEng, Lim, swam) At toast 1YAt:uvo Sol ,.._.. b.AZWand Prating SFWtlromthoFawiaS:n lsTreded with 8cra'sas(ar Uut Facfaylrry-+wpnaiW btwwi;6e)CR]�1 Was all fki.Maddef Woad 2. Use Ros>atad MdmidsinWa(aotxs of t(ildxm. lfoin�omw, U!31y Roans, and Basxaan!s ) rPonis tolo,msfgtlfy granted wimp pttOol-queruas krrraasam J3: ES Mb IA0) 3:0w FSC Cwt5v3 Etigrmaai LuYrkwr (3 p9ntsmaritmxnl ? Bosom arditeadas b. lasulaM Dinned Hoadare S c.Wood l, innrWubTtu .4uinr Floors Waists for Roof Hallam e.EndneaedorEInga,WMndStuds for Vortical App0catons I E RoaTrussoe; 103°A i 4. FSC Csaud Woad a Cimandanallumber, Stall and Macs; 1C0'i ,.,.....,,....,._.., .._.....,_ _ 2 ....,,...«.._.„_. a q ! •__. ..,,.,_,,,, ......,..,. .,. - �..., m�..., _.._ ,,......_.. , t - ....h-- .........__. - .,: ,.,,_ . ..,.„.-„__,_�..�_,�. Nos4 __..........__... ._ ie(5 4 _..... _. -'i8D• B I 0 I 0 .«.,�,-_>_..._..,....._.,.....,' B —_,.,.._......,..._______.__,._-_.._....,.........—..„. _,._.._....__.___...T..,_....µ...__..a _ :....,...,.„,._..__.�__.......,..__ t i . ......:......._....'..__. _._____ T 1 i i..._. ..., . : _.I.._..._. ..,. 3......_,...., .........................,..,..._........._.......,._.._......,_....,_,._._.....�..._. r I : T .........__,_..,,,..,...................._....._......_.,.._ hU h(a No �.....,,._....,..,.�:.. _.....,....,..._................................,.,..,.....,,.,,,_...,,.,.,..,....:.._._. Ye..1. ..,.... _.� :.. ._._..__._w_...,_. _..._.._ .._._.. ... ... '.'.,�......�,.'.. ....._..... „,._._. ...._......_...... ..... ._. ......................................__....._. ,_,...... ._._.,_. _ Flo No z tu' € ,. Yaa_- Ye3.1- _t a__.....,..._......_ ,.....:,...... .......................................... NOa N_......................._..........................,......'...... 0 1 0 [-a«.. 0 �.,........... ; 1,....,, l 1 .__._....._ i. ? t:......,...,,..�.�,.w,,,_,,.,.... - _......,........... No .....,, ................_,M..,....,._.„_...,....,_......,_..._...._,_.,.,.....,,. 001 Nod,Wobd ..... _...._...._ .__.,..._,.,.._,_,.,...., S ._......._ 1,...,,....„. Ne-- No . - ..N Yeb". 2 d ) ._....�. - __z__ ..,..,E.lnludxted..,r.F_„ ,.,..;. orFlnish t.G eon Pods)wabarm(eoa nn um) I 2FIas4arg lnstayaSaw Tu4011ursS{x6cd 7dntsvutmnw0ca!t2 yon(aduhon ptjsc(ttualifss famaasvn 23: ES with tan) . _ ...�...� `...�� ,._.... Nn'' F. Insulation .. B. Plumbing 1,Grayxa!otPtuP'ueddng(IraYudeawahngmadtineatn6rcrtrum) P.Gayxasr Syrian Dpuruiand(and xSw.e wasting marhzno at minimum) 3.burgess Wlaslawan Toitoolooy(Consartad Woland.Sard Filla,AnNic System) Cdn d:arcoang orWn1nu 1b0ai. 5.tnstdlC Water Haataecovary Syotcm 6. Instill Wa'a 010eie010Wosu a, Stvsawhsaisof ShxcaTaxoaa Usn.10Bekaa Pa Maa,+.o (GPM) Taisi kProofs -bahaaans e1.8 gpm eFangs •Kikhoa&U, c'1Dgpm TBD s 0 I i2 Fla. No - - i 0 t•"' """"""'_.. t7 ,..,,.., ? . ..... I Tom. : ,. .. ,,.................... .....: No- • No- ............._, ..,,....m: Yo>.:. t «._,.,..._ 1. Yd's .................................._...._....___._....,....� Von l-i......__.,M.__)r__..__...__._....„_..._ H, Heating, Ventilation, and Alr Conditioning I..Hum'd!NContol 0y4tamo jadyin California hu0Emmvino alma* talus l,3t,6,7) Yao' Build It Green SF Data Collection Fomt v,3,7 Page 4 of B No I INoI Yon No No No 50 No T(OD`' 50 No TB0 t.5' No No 1. Renewable Energy 1. Ed/wallet), Pa two Solar Design () 50%of loodj flat to NoIAboody Rollocted'n 144 Modolog J. Building Performance 1. To Tall SafpiyAtr Flow Rates 2. Eromtneyas Dedttn R4ifow a Teto44 prepaol and signed L5 CABE0 Ca60af EnbrgyAoky o b. Po•t ips0on io oot a protFun K. Finisher LIRA EtarmmcntdyPtetarokietdatuiaaktWarier Rd as a. CatinaisteWs mrs rom) b. Kea' Tern (50% rr¢rimm) o.StxVng (00%mirimum). d,Cous(tY%mitimum) o. Cantr tees (BO%mitto tm) I - Flooring 1. Morino Reale Sociton 01350 orCRl Coon label Plus Rootdiemurte (00 h Minlaac of Nif&nte, oulema0c gantod%Oen pitctquagga lot maim J3: ES with IA01 M.Apjpaneas N.0ther I, IleceeialeAea M 0000rnnl Slat aro Ct rtirxi Gime Boeing I'm(osdanas Oetdtoi Iar tatty Flan l'Ptin+a a daodkdfratn!sduium oni4ot wa`fns scc moaaun J3'. ES wilt IA01 5ktitd.Pa 1hRittaSmetimf{emrntetem ounat(5o i. Mabriets Sa:trol, Precasted erd MAuwfntg rod t'Jdkn a 5C0 Mtw Was of Iv Hem 5. Ccmp(ikaiyt t Ohm's Wool a,vi Horr oo)sar Eduon'uonalWdklhravakn S.yddtxoni Itnevegons: Points to bo asstuud by Pad IIGroon and GrainPekt1Ratu: a. OtteAttiiitoYeleyt Itete,-bogoteipo4» p.oitioVOColturosI.•P 5.:Dan ami Irni vatoR(lgm, a0Q EplerPotrlbfa t de)s55Cc1u.'ms L•P a: 0o4tloforWoOo0Hae aid.EntatPasrhk MAtan COIJmne GP 4 W4a0e (tp»veEop Ne,,e, end Ente pess,hk3Paints t1194 t0. tiP a. Dosia oiixxriotogtlor andEtinrPossibleP(dnta4TWorrnsL'•P L144it hn:: ooton Ngto: aid EnioGpocdbb pdnw m CoNgsu L.P g "0awirairia✓oDCntjao test Met Po blePdotoEColurcruL•0 h..Doo04ttV ia$tsiNero;anitEniofPacabkPi ltekr`br�` ums4-P Val Actum'ooda Pottle in Ins»ua!ktt.20 ... TaialAviiab0 Paint Ge SpteakCa:nodes Meroan Po0)b Rocarod k Sp eitte 05og o0o Peojoet lino mat nit rocommondert minimum requirement, .Oi'F':o r'oo tit 'A&'life!y: vi, fJ: 5f?iC waste (1 ritsv'0 1.. nata jf 7/110 risC{1t 1Cli640 o5teitiriFitin ko/ f:�iif: elt' Prs0)tt 0 it? SpO':tI(C }t.<0....itkttt i 5 pct., tt 0 32+ 1125+ 51+ 1103+ 0 i 30 t 5 I 6 i0 Build It Green 8F Data Collection Form v.3.7 1 7 Pogo 5 of 0 INITIAL STUDY —16005 Los GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD ATTACHMENT 6 REVIEW OF PROJECT SUBMITTALS FOR • COMPLIANCE WITH STORMWATER REQUIREMENTS BY . EISENBERG, OLIVIERI & ASSOCIATES NOVEMBER 15, 2010 Eisenberg, Olivier! & Associates Environmental and Public Health Engineering MEMORANDUM TO: John Gaylord, Town of Los Gatos FROM: Jill Bicknell, P.E. DATE: November 15, 2010 SUBJECT: 16005 Los Gatos Blvd, Mixed Use Project — Conceptual Plan Review #2 • Review of Project Submittals for Compliance with Stormwater Requirements Project Description This redevelopment project located at the corner of Los Gatos Boulevard and Blossom Hill Road will consist of 47 single family residential units, one retail building, and one building with a combination of retail and 10 units of senior housing. The existing site was previously used as an auto dealership and contains several existing buildings and pavement covering most of the rest of the site, The total site area is 4.49 acres, and the existing impervious area is 4.28 acres (95,2%). After construction of the proposed project, the impervious area will be reduced to 3.4 acres (75.6%). I performed a regulatory review of the project and submitted comments on May 22, 2010. The applicant resubmitted plan sheets and responses to comments on September 30, 2010. I reviewed the following: Plan Sheets for "Mixed Use Project — Blossom Hill Road at Los Gatos Boulevard", 6/3/10: o C-6.0: Stormwater Treatment Plan. I reviewed the project submittals for compliance with the stormwater requirements in the Town of Los Gatos' NPDES Permit' and consistency with related ordinances2. The project submittals are still considered to be at the conceptual stage; therefore, some information on the stormwater treatment measure sizing calculations and design details were not provided or reviewed. My comments on the applicant's responses are presented below: Comments and Responses Comment a. (5/22/10 memo) While the treatment measures selected are technically allowed under the current permit requirements, it is recommended that the applicant look for additional opportunities for stormwater treatment in landscaped features as opposed to treating the majority of the residential area with manufactured devices. For example, the swale and common area in the southwest corner of the site could be used for stormwater infiltration. A recommended site design measure, which the engineer says will be incorporated but is not shown on the plans, is to drain the single family home roofs to landscaping. Pervious paving could also be used for some of the entrance roads and driveways, or in the patio area of the retail building. I California Regional Water Quality Control Board, San Francisco Bay Region, Municipal Regional Stormwater NPDES Permit, Order No. R2-2009-0074, October 14, 2009, Provision C.3. 2 Town of Los Gatos Municipal Code, Chapter 12, Article II. Grading Permit, Sec. 12.20.050 Erosion control plan, Chapter 12, Article ill. Design Standards, Sec. 12,30.080, Erosion and sediment control, and Chapter 22, Article III. Stormwater Pollution Control, Sec.22.30.035. New development/redevelopment, 1 EOA, Inc. • 1 1 1 W. Evelyn Ave. • Sunnyvale, CA 94086 • Tel: (408) 720-8811 • Fax: (408) 720-8812 Applicant Response As the design moves forward, the civil team will assess all areas for natural cleansing as well as pervious pavement area. Engineering team is waiting for a soils investigation to determine the percolation of existing soils. Response to Applicant This response is acceptable. The revised Sheet C-6.0 has also eliminated one Filterra unit, so that now all of the runoff from the commercial area drains to bioswales. Comment b. (5/22/10) For this stage of the planning process, it is recommended that the Town request the applicant to submit a revised version of Sheet C-6.0. At a minimum, the "Swale C Tributary Area" should be shown to drain to the Filterra unit instead of Bioswale C, and the Filterra unit size indicated. Applicant Response Please refer to the revised plan, Area C drains to a Filterra, sizing information is included. Response to Applicant Revised Sheet C-6.0 clearly shows the drainage areas and treatment measures. The three drainage areas in the residential portion of the site drain to three Filterra units. The Filterra units are correctly sized per the manufacturer's sizing chart,. based on a design flow intensity of 0.2 inches per hour, which is in compliance with Provision C.3.d. of the Town's stormwater permit. Two bioswales, shown in four segments on the plan, will be located on the eastern edge of the site along Los Gatos Boulevard and will receive runoff from the entire commercial portion of the site. Stormwater residence times were listed for the bioswales, and these times are more than sufficient for adequate treatment. No design details were provided for the bioswales, so the calculated residence times cannot be checked. However, the area reserved for the bioswales ranges from roughly 5 to 20% of the contributing drainage area, which should be sufficient for adequate treatment. Comment c. (5/22/10) The Town and applicant should be aware that if this project does not complete "final discretionary review" before December 1, 2011, it will be subject to new Low Impact Development (LID) treatment requirements in the Town's permit, which limit the treatment options to infiltration, evapotranspiration, and rainwater harvest and use. If these are infeasible on the site, the applicant may use "biotreatment" (i.e., bioretention or infiltrating swales). The Filterra units do not currently meet the definition of biotreatment because of rapid infiltration rate of their filter media. Applicant Response Design team is aware of the time limitations. 1 believe the project team is aiming to complete review prior to that date. Response to Applicant This response Is acceptable. Conclusions The applicant has addressed the comments in my 5/22/10 memo and I have no additional comments on the current submittal. The design details and sizing calculations for the bioswales will need to be provided for final approval of the stormwater plan for this project. 16005 Los Gatos Blvd Review #2 11-15-10.doo 2 INITIAL STUDY -16005 LOS GATOS BOULEVARD AND 625 BLOSSOM HILL ROAD ATTACHMENT 7 NOISE ASSESSMENT STUDY FOR THE PLANNED MIXED -USE DEVELOPMENT Los GATOS BOULEVARD AND BLOSSOM HILL ROAD . Los GATOS BY EDWARD L. PACK ASSOCIATES, INC. OCTOBER 15, 2010 EDWARD L. PACK ASSOCIATES, INC. 1975 HAMILTON AVENUE SUITE 26 SAN JOSE, CA 95125 Ms. Valerie Geier Geier & GeierConsulting, Inc. P.O. Box 5054 Berkeley, CA 94705 Acoustical Consultants TEL: 408-371-1195 FAX: 408-371-1196 www.packassociates.com October I5.2010 Project No. 42-014-1 Subject: Noise Assessment Study for the Planned Mixed -(.Ise .Development, 16005 Los Gatos Boulevard, Los Gatos Dear Ms. Geier: This report presents the results of a noise assessment study for the planned mixed -use development at 16005 Los Gatos Boulevard in Los Gatos, as shown on the Site Plan, Ref. (a). The noise exposures at the site were evaluated against the standards of the Town of Los Gatos Noise Element, Ref (b), and the State of California Code of Regulations, Title 24. Ref. (c), which applies to the multi -family housing portion. of the project. The analysis of the on -site sound level measurements indicates that the existing noise environment at the site is due primarily to traffic sources on Los Gatos Boulevard and Blossom I1i11 Road The results of the study reveal that exterior and interior noise exposure excesses occur and mitigation measures will be required. Sections I and II of this report contain a summary of our findings and recommendations. respectively. - Subsequent sections contain the site, traffic, and project descriptions, analyses and evaluations. Attached hereto are Appendices A, 13, and C, which include the list of references, descriptions of the applicable standards. definitions of the terminology, descriptions of the acoustical instrumentation used for the field survey, ventilation requirements, general building shell controls, and the on -site noise measurement data and calculation tables. MEMBER: ACOUSTICAL SOCIETY OF AMERICA NATIONAL COUNCIL OF ACOUSTICAL CONSULTANTS -2- I. Summary of Findings The noise assessment results presented in the findings are shown in reference to the Town of Los Gatos Noise Element, which utilizes the Day -Night Level (DNL) 24- hour noise descriptor to define community noise impacts. The Noise Element, Section H.P.1.7. (Policies), states to pursue a 55 decibel (dB) DNL outdoor noise limit as representing the long range community aspirations and work toward their accomplishment, even though some may not be presently unattainable. The Noise Element specifies a limit of 45 dB DNL for residential interiors. For commercial uses, the Noise Element specifies a limit of 70 dBA averaged over 24 hours with no time weighting (Leq(24)). For common open space, the Noise Element specifies an exterior noise limit of 55 dBA Leq(24). Due to the existing noise exposures at the site, achieving 55 dB DNL at the private exterior areas (balconies and decks) will not be feasible. Therefore, the Town should impose a design noise goal of 60 dB DNL for the exterior living areas (side and rear yards) of the single-family homes of the project and 65 dB DNL for the multi -family exterior areas (balconies) of the project. Noise design goals of 60 dB DNL for single- family homes and 65 dB DNL for multi -family units are the noise exposures recommended by the State of California for adoption into Noise Elements throughout the State. We concur that these goals are reasonable and attainable for this project. The Title 24 standards also use the DNL descriptor and specify that when the exterior noise exposures exceed 60 dB DNL at planned multi -family dwelling units an acoustical analysis must be performed to limit interior noise exposures to 45 dB DNL or less. -3- The Title 24 standards also specify minimum sound insulation ratings for common partitions separating different dwelling units and dwelling units from interior common spaces. The standards specify that common walls and floor/ceiling assemblies must have a design Sound Transmission Class (STC) rating of 50 or higher. As design details for the interior partitions of the project were not available at the time of this study, an evaluation of the interior partitions has not been made. The noise levels shown below are without the application of mitigation measures and represent the noise environment for existing site conditions. A. Exterior Noise Exposures • The existing exterior noise exposure in the most impacted balconies and planned minimum setback of units from Los Gatos Boulevard (79 ft. from the centerline) is 67 dB DNL. Under future traffic conditions, the noise exposure is expected to increase to 68 dB DNL. Thus, the noise exposures will be up to 3 dB in excess of the recommended noise goal for the balconies and up to 8 dB in excess of the Title 24 criterion. • The exterior noise exposures in the patio of Building 1 along Los Gatos Boulevard will be 53-56 dBA Leq(24) under existing traffic conditions and 54-57 dBA Leq(24) under future traffic conditions. Thus, the noise exposures will be within the 70 dBA Leq(24) standard of the Town of Los Gatos Noise Element. • The exterior noise exposures in the patio of Building 2 along Los Gatos Boulevard will be 51-55 dBA Leq(24) under existing traffic conditions and 52-56 dBA Leq(24) under future traffic conditions. Thus, the noise exposures will be within the 70 dBA Leq(20 standard of the Town of Los Gatos Noise Element. - 4 - • The existing exterior noise exposure at the most impacted planned building setback at the first floor of homes from. Blossom Hill Road (52 ft. from the centerline) is 64 dB DNL. Under future traffic conditions, the noise exposure is expected to increase to 65 dB DNL. • At the most impacted upper floor building setback, the noise exposures are 65 and 66 dB DNL under existing and future traffic conditions, respectively. • The exterior noise exposure in the most impacted side and rear yards of homes along Blossom Hill Road will be 62 and 63 dB DNL under existing and future traffic conditions, respectively. Thus, the noise exposures will be up to 8 dB in excess of the 55 dB DNL limit of the Town of Los Gatos Noise Element, but will be 3 dB in excess of the recommended 60 dB DNL noise goal recommended for this project. The exterior noise exposures in the balconies of the four units facing Los Gatos Boulevard (Units 1-4) exceed the 65 dB DNL noise goal recommended for this project. The exterior noise exposures in the side and rear yards of the homes closest to Blossom Hill Road will also exceed the 60 dB DNL noise goal recommended for this project. Mitigation measures, therefore, will be required. The recommended measures are described in Section II, below. As the exterior noise exposures at the planned building setback of the multi- family units exceed the criterion of Title 24, an acoustical analysis is required. This study is intended to satisfy that requirement. -5- B. Interior Noise Exposures • The interior noise exposures in the most impacted planned dwelling units closest to Los Gatos Boulevard will be up to 52 and 53 dB under existing and future traffic conditions, respectively. Thus, the noise exposures will be up to 8 dB in excess of the standards of the Town of Los Gatos Noise Element and Title 24. • The interior noise exposures in the most impacted planned homes closest to Blossom Hill Road will be up to 50 and 51 dB under existing and future traffic conditions, respectively. Thus, the noise exposures will be up to 6 dB in excess of the standards of the Town of Los Gatos Noise Element. As shown above, interior noise exposure excesses will occur and mitigation measures will be required. The recommended measures are described in Section II, below. II. Recommendations A. Exterior Noise Control To achieve compliance with the 55 dB DNL limit of the Town of Los Gatos Noise Element at the noise impacted balconies and decks, complete enclosure of balconies and decks would be required, rendering these spaces no longer exterior spaces. A noise design criterion of 55 dB DNL in a suburban setting along major roadways is not a practical goal. To achieve compliance with the 65 dB DNL noise design goal recommended for the multi -family balconies of this project, noise control balcony railings will be required, as described below: - 6 - • Construct 42 in. high acoustically -effective balcony railings at the balconies of Units 1-4 along Los Gatos Boulevard. The balcony railing height is in reference to the nearest balcony floor elevation. To achieve compliance with the 60 dB DNL noise design goal recommended for the single-family side and rear yards, the following noise control barriers will be required, as described below: 1) Construct 6 ft. high acoustically -effective barriers between the homes on Lots 1-5 and at the west side of Lot 5 to terminate near the garage. The barriers shall connect air -tight to the sides of the homes. The barrier height is in reference to the nearest building pad elevation. Please see Figure 1 for the locations of the recommended noise control barriers. To achieve an acoustically -effective barrier, it must be constructed air -tight, i.e., without cracks, gaps or other openings, and must provide for long term durability. The barriers can be constructed of masonry, wood, concrete, stucco, metal, earth berm or a combination thereof, and must have a minimum surface weight of 2.5 lbs. per sq. ft. If wood fencing is used, homogeneous sheet materials are preferable to conventional wood fencing as the latter has a tendency to warp and form openings with age. However, high quality air -tight tongue -and -groove, board and batten or shiplap construction can be used provided that the construction is air -tight and the minimum surface weight is met. Gates may be incorporated into the barriers, however, they must be meet the minimum surface weight and height requirements and must fit tight when closed. Astragals or stops shall be used over the hinge jamb and closure jamb gaps. A gap under a gate may be no more than 1" high. All connections with posts, pilasters and the building shell must be sealed air -tight. No openings are permitted between the upper barrier components and the ground. The implementation of the above recommended measures will reduce the exterior noise exposures to 65 dB DNL or lower in the noise impacted balconies of the multi- family units and to 60 dB DNL or lower in the single-family rear and side yards. rIAL STIEETSCAP . PLANTING. CHANT(LEER FLOWERING LOT 11 APE MYRTLE OR F TOWERING- )D W/ WATER-CONOERVING GRt3UN .GIVERS). ; `�- L1 LOT 10 )SEP GRANITIC AREA W/ BEN:GHES,. TREES TO -. IEt L(TYP.) ,r' 3tt 4 35 12 WO= STORY ES1p,piTIAL FREES I (TYP.) LOT 8 14 1 STREET „A" LOT 4 GATE LOT 25 f' LOT 26 J LOT 27 LOT 28 LOT 29 EXISTING REDWOOD TREE TO BE REMOVED' STONE, ENTRY yv,A,cL.(TO MATCH .DLDG. COLUMNS) AND`ORNAMENTAL WATERFALL FOUNTAIN WITH PROJECT SIGNAGE ON WALL FIGURE 1 Locations of the recommended 6 ft. high acoustically -effective barriers. The barrier height is in reference to the nearest building pad elevation. -7- B. Interior Noise Control To achieve compliance with the 45 dB DNL interior standard of Town of Los Gatos Noise Element and Title 24, the following window controls will be required: • Maintain closed at all times all windows and glass doors of living spaces within 270 ft. of the centerline of Los Gatos Boulevard and with a direct or side view of the roadway (Units 1-5). Install windows and glass doors rated minimum Sound Transmission Class (STC) 28. Provide some type of mechanical ventilation. • Maintain closed at all times all windows and glass doors of living spaces within 120 ft. of the centerline of Blossom Hill Road and with a direct or side view of the roadway (Lots 1-5). Install windows and glass doors rated minimum Sound Transmission Class (STC) 28. Provide some type of mechanical ventilation. When windows and doors are maintained closed for noise control, some type of mechanical ventilation to assure a habitable environment must be provided. The mechanical ventilation requirements specified by the Uniform Building Code (UBC) are described in Appendix B. The windows specified to be maintained closed are to be operable, as the requirement does not imply a "fixed" condition. All other windows of the project and all bathroom windows may have any type of glazing and may be kept opened as desired unless the bathroom is an integral part of a living space without a closeable door. -S- In addition to the required STC ratings, the windows and doors shall be installed in an acoustically -effective manner. To achieve an acoustically -effective window construction, the sliding window panels must form an air -tight seal when in the closed position and the window frames must be caulked to the wall opening around their entire perimeter with a non -hardening caulking compound to prevent sound infiltration. Exterior doors must seal air -tight around the full perimeter when in the closed position. Please be aware that many dual -pane window and glass door assemblies have inherent noise reduction problems in the traffic noise frequency spectrum due to resonance that occurs within the air space between the window lites, and the noise reduction capabilities vary from manufacturer to manufacturer. Therefore, the acoustical test report of all sound rated windows and doors should be reviewed by a qualified acoustician to ensure that the chosen windows and doors will adequately reduce traffic noise to acceptable levels. The implementation of the above recommended measures will reduce excess noise exposures to achieve compliance with the interior noise exposure standards of the Town of Los Gatos and Title 24. III. Site, Traffic and Project Descriptions The planned project site is located at the southwest quadrant of the intersection of Los Gatos Boulevard and Blossom Hill Road in Los Gatos. The 4.40 acre site is relatively flat and at -grade with the surrounding roadways. The presently contains the former Swanson Ford automobile dealership, which is occupied by Akeena Solar. Surrounding land uses include an office building and single-family residential across Placer Oaks Drive to the north, two-story apartment adjacent to the west, retail uses across Blossom Hill Road to the south and retail uses across Los Gatos Boulevard to the east. -9- The primary sources of noise in the site vicinity are traffic on Los Gatos Boulevard, which carries an Average Daily Traffic (ADT) of 22,630 vehicles and Blossom Hill Road carries an ADT volume of approximately 16,350 vehicles, as reported by the consulting traffic engineer for the project, Ref. (d). The planned project includes the construction of 23,267 sq. ft. of retail space on the ground floors of the two building along Los Gatos Boulevard with senior housing on the second floor of the northerly building (Building 1). The project also includes 29 single-family homes. Ingress and egress to the project are by way of driveways off of Los Gatos Boulevard, Blossom Hill Road and Placer Oaks Road. IV. Analysis of the Noise Levels A. Existing Noise Levels To determine the existing noise environment at the site, continuous recordings of the sound levels were made at two locations. Location 1 was 128 ft. from the centerline of Los Gatos Boulevard. Location 2 was 50 ft. from the centerline of Blossom Hill Road. The measurements were made on April 13-14, 2010 for a continuous period of 24 hours at each location and included representative hours during the daytime and nighttime periods of the DNL index. The noise level data were acquired using Larson -Davis Model 812 Precision Integrating Sound Level Meters. The meters yield, by direct readout, a series of descriptors of the sound levels versus time, which are commonly used to describe community noise, as described in Appendix B. The measured descriptors include the LI, Lip, L50, and L90, i.e., those levels exceeded 1%, 10%, 50% and 90% of the time. Also measured were the maximum and minimum levels and the continuous equivalent -energy levels (Leg), which are used to calculate the DNL's. The results of the measurements are shown in the data table sin Appendix C. -10- The results of the field survey reveal that the Leq's at Location 1, 128 ft. from the centerline of Los Gatos Boulevard, ranged from 60.3 to 65.2 dBA during the daytime and from 49.7 to 58.3 dBA at night. The Leq's at Location 2, 50 ft. from the centerline of Blossom Hill Road, ranged from 59.8 to 66.0 dBA during the daytime and from 46.9 to 58.0 dBA at night. Traffic noise dissipates at the rate of 3 to 6 dB for each doubling of the distance from the source (centerline of the roadway) to the receiver. Therefore, other locations on the site at greater distances to the roadways will have lower noise levels. Additional noise shielding will be provided by interposed buildings of the project. Vehicular traffic noise contains wide spectra of frequency components (from 100 to 10,000 Hertz), which are associated with engine, tire, drive -train, exhaust and other sources. The frequency components are centered primarily in the 500 and 1,000 Hz octave bands and were used in determining the noise control measures recommended for this project. B. Future Noise Levels The future traffic volumes for Los Gatos Boulevard and Blossom Hill Road were provided by the consulting traffic engineer, Ref. (d). The future traffic volume for Los Gatos Boulevard is expected to increase from the existing 22,630 ADT to 28,120 ADT under the Cumulative + Future Redevelopment of Auto Dealerships scenario. This increase in traffic volume yields a 1 dB increase in the traffic noise levels. The future traffic volume for Blossom Hill Road is expected to increase from the existing 16,350 ADT to 21,100 ADT under the same future scenario. This increase in traffic volume also yields a 1 dB increase in the traffic noise levels. -11- V. Evaluations of the Noise Exposures A. Exterior Noise Exposures To evaluate the on -site noise exposures against the Town of Los Gatos standards and the Title 24 criterion, the DNL's for the survey locations were calculated by decibel averaging of the Leas as they apply to the daily time periods of the DNL index. The DNL is a 24-hour noise descriptor that uses the measured Leg values to calculate a 24-hour time -weighted average noise exposure. The formula used to calculate the DNL is described in Appendix B. The 24-hour Leq's were calculated by decibel averaging of the hourly Leq's without daytime or nighttime weighting factors. Adjustments were made to the measured noise levels to account for the various building setback distances from the roadways and measurement locations using methods established by the Highway Research Board, Ref. (e). The noise exposure calculations are shown in greater detail in Appendix C. The results of the calculations indicate that the exterior noise exposures at measurement Location 1, 128 ft. from the centerline of Los Gatos Boulevard and at the second floor elevation, are 64 dB DNL and 61 dBA Leq(24) under existing traffic conditions. At the most impacted planned building setback and in the most impacted balconies of the multi -family units, 79 ft. from the centerline of the roadway, the noise exposure was calculated to be 67 dB DNL. Under future traffic conditions, the noise exposure is expected to increase to 68 dB DNL. Thus, the noise exposures will be up to 8 dB in excess of the Title 24 criterion and up to 3 dB in excess of the 65 .dB DNL noise goal recommended for this project. In the patio of Building 1 of the commercial portion of the project, the noise exposures were calculated to be 53-56 dBA Leq(24) under existing traffic conditions, and 54-57 dBA Leq(24) under future traffic conditions. Thus, the noise exposures will be within the limits of the Town of Los Gatos Noise Element standards. -12- In the patio of Building 2 of the commercial portion of the project, the noise exposures were calculated to be 51-55 dBA Leq(24) under existing traffic conditions, and 52-56 dBA Leq(24) under future traffic conditions. Thus, the noise exposures will be within the limits of the Town of Los Gatos Noise Element standards. At measurement Location 2, 50 ft. from the centerline of Blossom Hill Road the noise exposures were calculated to be 65 dB DNL and 63 dBA Leq(24). At the most impacted planned building setback of the first floor elevation of the single-family homes, 52 ft. from the centerline of the roadway, the noise exposures were calculated to be 64 dB DNL under existing traffic conditions and 65 dB DNL under future traffic conditions. At the upper floor setbacks of the homes, the noise exposures were calculated to be 65 and 66 dB DNL under existing and future traffic conditions, respectively. In the most impacted side yards of the homes closest to Blossom Hill Road, the noise exposures were calculated to be 62 and 63 dB DNL under existing and future traffic conditions, respectively. A 2 dB downward adjustment was applied to the noise exposure at the building setback to account for partial shielding of traffic noise provided by the buildings of the project. Thus, the noise exposures will be up to 3 dB in excess of the 60 dB DNL noise goal recommended for this project. B. Interior Noise Exposures To evaluate the interior noise exposures in project living spaces, a 15 dB reduction was applied to the exterior noise exposure to represent the attenuation provided by the building shell under annual -average conditions. The annual -average condition assumes that windows have single -strength (3/32") glass and are kept open up to 50 % of the time for natural ventilation. Thus, the interior noise exposures in living spaces closest to Los Gatos Boulevard will be 52 dB DNL under existing traffic conditions and 53 dB DNL under future traffic conditions. Thus, noise exposures will be up to 8 dB in excess of the standards of Town of Los Gatos Noise Element and Title 24. - 13 - The interior noise exposures in living spaces closest to Blossom Hill Road will be 50 dB DNL under existing traffic conditions and 51 dB DNL under future traffic conditions. Thus, noise exposures will be up to 6 dB in excess of the standards of the Town of Los Gatos Noise Element. As shown by the above evaluations, exterior and interior noise exposures excesses will occur and mitigation measures will be required. The recommended mitigation measures are in described in Section II of this report. This report presents the results of a noise assessment study for the planned mixed -use development at 16005 Los Gatos Boulevard in Los Gatos. The study findings and recommendations are based on field measurements and other data and are correct to the best of our knowledge. However, significant changes in the predicted traffic volumes, speed limits, motor vehicle technology, noise regulations, or other future changes beyond our control may produce long-range noise results different from our estimates. If you have any questions or would like an elaboration on this report, please call me. Sincerely, EDWARD L. PACK ASSOC., INC. Jeffrey IC. Pack President Attachments: Appendices A, B, and C (e) APPENDIX A References (a) Site Plan, "Los Gatos Boulevard and Blossom Hill Road", by Kenneth Rodrigues & Partners, Inc., August 2, 2010 (b) Town of Los Gatos General Plan, Chapter 8.0, "Noise Element", July, 2000 (c) California Code of Regulations, Title 24, Part II, "Sound Transmission Control", Revised 1989 (d) "Traffic Impact Study for the Proposed Mixed -Use Development at 16005 Los Gatos Boulevard", by TJKM Transportation Consultants, December 23, 2009 Highway Research Board, "Highway Noise - A Design Guide for Highway Engineers", Report 117, 1971 APPENDIX B Noise Standards, Terminology, Instrumentation Ventilation Requirements, and Building Shell Controls 1. Noise Standards A. Town of ,Los Gatos Noise Element Standards The Noise Element of the General Plan of the Town of Los Gatos, adopted July, 2000, specifies noise limits for various land uses. Land Use dB DNL dBA Leq(24) Residential 55 Commercial 70 Industrial 70 Open Space Intensive (developed park) 55 Passive (natural park) 50 Hospital 55 Educational 55 Interior noise exposures for single-family developments are specified to be the same as multi -family developments. This statement asserts coincidence with the standard of the State of California Code of Regulations, Title 24 noise limit of 45 dB DNL for all new housing. B-1 B. Title 24 Noise Standards The California Code of Regulations, "Sound Transmission Control", Title 24, Part II, applies to all new multi -family dwellings including condominiums, townhouses, apartments, hotels and motels. The standards, which utilize the Day -Night Level (DNL) descriptor, establish an exterior reference or criterion level of 60 dB DNL, and specify that multi -family buildings to be located within an annual DNL zone of 60 dB or greater require an acoustical analysis. The analysis report must show that the planned buildings provide adequate attenuation to limit intruding noise from exterior sources to an annual DNL of 45 dB or less in any habitable space. The Community Noise Equivalent Level (CNEL) descriptor, which is similar to the DNL, may also be used, as the DNL and CNEL are considered to be equivalent. The Title 24 standards also establish minimum sound insulation requirements for interior partitions separating different dwelling units from each other and dwelling units from common spaces such as garages, corridors, equipment rooms, etc. The common interior walls and floor/ceiling assemblies must achieve a minimum Sound Transmission Class (STC) rating of 50 for airborne noise. Common floor/ceiling assemblies must achieve an Impact Insulation Class (IIC) rating of 50 for impact noise. These ratings are based on laboratory tested partitions. Field tested partitions must achieve ratings of NIC and FIIC 45. B-2 2. Terminology A. Statistical Noise Levels Due to the fluctuating character of urban traffic noise, statistical procedures are needed to provide an adequate description of the environment. A series of statistical descriptors have been developed which represent the noise levels exceeded a given. percentage of the time. These descriptors are obtained by direct readout of the Community Noise Analyzer. Some of the statistical levels used to describe community noise are defined as follows: L i A noise level exceeded for 1% of the time. Li0 A noise level exceeded for 10% of the time, considered to be an "intrusive" level. L50 The noise level exceeded 50% of the time representing an "average" sound level. L90 The noise level exceeded 90 % of the time, designated as a "background" noise level. Leg The continuous equivalent -energy level is that level of a steady-state noise having the same sound energy as a given. time -varying noise. The Leg represents the decibel level of the time -averaged value of sound energy or sound pressure squared and is used to calculate the DNL and CNEL. 13-3 B. Dav-Night Level (DNL) Noise levels utilized in the standards are described in terms of the Day -Night Level (DNL). The DNL rating is determined by the cumulative noise exposures occurring over a 24-hour day in terms of A -Weighted sound energy. The 24-hour day is divided into two subperiods for the DNL index, i.e., the daytime period from 7:00 a.m. to 10:00 p.m., and the nighttime period from 10:00 p.m. to 7:00 a.m. A 10 dB weighting factor is applied (added) to the noise levels occurring during the nighttime period to account for the greater sensitivity of people to noise during these hours. The DNL is calculated from the measured Leq in accordance with the following mathematical formula: Where: DNL = [(Ld+l0logiol5) & (4+10+101ogio9)] - 101ogio24 Ld = Leq for the daytime (7:00 a.m. to 10:00 p.m.) L„ = Leq for the nighttime (10:00 p.m. to 7:00 a.m.) 24 - indicates the 24-hour period & - denotes decibel addition. C. A -Weighted Sound Level The decibel measure of the sound level utilizing the "A" weighted network of a sound level meter is referred to as "dBA". The "A" weighting is the accepted standard weighting system used when noise is measured and recorded for the purpose of determining total noise levels and conducting statistical analyses of the environment so that the output correlates well with the response of the human ear. B-4 3. Instrumentation The on -site field measurement data were acquired by the use of one or more of the precision acoustical instruments shown below. The acoustical instrumentation provides a direct readout of the L exceedance statistical levels including the equivalent -energy level (Leg). Input to the meters was provided by a microphone extended to a height of 5 ft. above the ground. The meter conforms to ANSI S 1.4 for Type 1 instruments. The "A" weighting network and the "Fast" response setting of the meter were used in conformance with the applicable ISO and IEC standards. All instrumentation was acoustically calibrated before and after field tests to assure accuracy. Bruel & Kjaer 2231 Precision Integrating Sound Level Meter Larson Davis LDL 812 Precision Integrating Sound Level Meter Larson Davis 2900. Real Time Analyzer 4. Ventilation Requirements Ventilation requirements to be applied when windows are maintained closed for noise control are specified in the Uniform Building Code (UBC), 2001 edition, Section 12.03.3 as follows: "In lieu of required exterior openings for natural ventilation, a mechanical ventilating system may be provided. Such system shall be capable of providing two air changes per hour in guest rooms, dormitories, habitable rooms, and in public corridors with a minimum of 15 cubic feet per minute (7L/s) of outside air per occupant during such time as the building is occupied." Based on our previous experience, a "summer switch" on the furnace fan is normally considered acceptable as a ventilation system by FHA and other agencies. Air- conditioning is also an acceptable system. B-5 5. Building Shell Controls The following additional precautionary measures are required to assure the greatest potential for exterior -to -interior noise attenuation by the recommended mitigation measures. These measures apply at those units where closed windows are required: • Unshielded entry doors having a direct or side orientation toward the primary noise source must be 1-5/8" or 1-3/4" thick, insulated metal or solid -core wood construction with effective weather seals around the full perimeter. Mail slots should not be used in these doors or in the wall of a living space, as a significant noise leakage can occur through them. • If any penetrations in the building shell are required for vents, piping, conduit, etc., sound leakage around these penetrations can be controlled by sealing all cracks and clearance spaces with a non - hardening caulking compound. • Fireplaces should be provided with tight -fitting dampers. B-6 APPENDIX C Noise Measurement Data and Calculation Tables • v DNL CALCULATIONS GEIER & GEIER 0 D' J O r 0 J O 03 to E O O • 4 OO N Z O O (/) U w: O 0 N J O O' J Ps 01 r II 11 II 2 II 0) 1.-..NNNC)1`0P U)Ps. ti00C)(0st 00000N01 0) Nf.Nt+Or00)Nh0) VNI-1iL0 ✓ O OO)MMM M N00 1 N. Ps OO) et N 00) CO0O 000 O0000)) . (0000') 00 r O r r r 0 N 00 N O O 0 00 st O ti 0) 0 0 N 0) ,- N st 00 r r r r r (O s- CO C) r O 00 0 01 (C) CD N st (O O t- CO 7. O 0) O C) C) C) P.r 00 r (O O 0) N 0) (0 N r T. r r (+) (1) M M C) C) C) M M C) N C) C) C) s-- s- L0 O 00 N N N 1` O u) O CO CO 00 r 00 O r C) 0 0 e- st NI 0 ui u) u) ui u)st u) u) Ti (V.- O) 00 Ti (V r(0 (V 00 (C)N CO CO CO (O 0 (0 OD (O (0 (0 0 (0 CO CO 0 u) u) (n u) st 0 u) () 0 ¢aaQQOaaaadaCaOO..aa¢¢¢¢¢¢¢ O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O 6 r N 0 0 0 0 0 0 0 0 0 Cor N 0 0 09 0 0 F- 00 0) r s- r .- N co d (t) (0 I. 00 0) s- s- .- - N M V' in CO Los Gatos Blvd. 00 00 u) • (NIcn CO 0) 00 00 N ✓ r- (0 • st • 0 00 (O N 11 I I M II II J CO J I� r 00 N r 0) 0) 0) 0) co 0) 0) N M N 1` N 00 st 0) co O st O O ti O r (0 (0 h h. N. N O O M 0) 00 C) u) O) (A O O Ti 0) C) (0 00 O r 0) M C) M C) CO O O 0) Psst 0) OO CV Ps 0 st (0 00 st CD Ps r) CV OD Ps Ps 1s CV Ps Psr 00 0 et 00 0) st M st O 0 00 O 144 N 0) r 0) 00 r r r 0 0) 0 st r CO OD r N M 0 0 st (0 (0 00) 000 00 M O M O O O 00) CO 000 u0) O O u0) (0+) . 0 (sl\1 O.- et U7 ✓ r r C) N N N N N 00 I's (O N N CO r r r 0 0 OO O M st Ps 0 ps h 0 O (D N M (V N CV 0 C) C) 0) C) M M N N (V O O h Ti O 0) C) 0 r (0) OS CO (O (0 (O CO (O (O (O (O (0 (O (0 (0 (0 (0 0 0 0 '. 0 0 0 0 0 <¢ ¢ 4 0 0 0 Oa. a a a a n. a a a a c, ¢ Q Q¢¢ Q a O 0 0 0 0 0 0 0 0 0 0 0 0 O O 0 0 0 0 0 0 0 0 0 O OOD r N0000000000 s._,N 000000 I- 00 O) r r s- r (V 01 st 00 (0 1s 00 CO r rrr N co st (l) (0 CO. N Ps � (0