Exhibit 9.Development PlansELECTRICPANEL(E) BEDROOM8'-0"(E)(E) BEDROOM13' 9 1/8" X 11' 1 5/8"8'-0"(E)(E) GARAGE20' 1 3/4" X 21' 3 1/4"8'-10"(E)(E) ENTRY6' 11 1/2" X 4' 10"8'-0"(E)94"x36"h: 3' 4"68"x20"h: 4' 6"30"x80"28"x80"84"x80"28"x80"36"x80"192"x82"70"x80"58"x80"28"x80"32"x80"36"x80"14"x30"h: 4' 4"GAS METERELECTRIC METERCRAWLSPACEACCESS6'-0"7'-0"32'-158"42'-678"44'-0"24'-0"3'-0"13'-0"3'-0"Vasona Oaks Dr33'-012"32"x80"72"x80"RECONFLAUNDRYRM.PREFABDUMBWAITER(N)TANKLESSW.H.WINE CELLAR @ FINISHED CRAWLSPACE BELOW GARAGE FLOOR(N)AC30"x80" (N)WATERSOFTENER(N) COVERED PATIORECONFBATHROOM3'-0"CLEARANCE3'-0"CLEARANCEWATERHEATERELECTRICPANEL(E) BEDROOM13' 4 1/8" X 16' 4 1/8"8'-0"(E)(E) BEDROOM13' 9 1/8" X 11' 1 5/8"8'-0"(E)(E) BATH10' 4 7/8" X 4' 10 7/8"8'-0"(E)(E) GARAGE20' 1 3/4" X 21' 3 1/4"8'-10"(E)(E) ENTRY6' 11 1/2" X 4' 10"8'-0"(E)94"x36"h: 3' 4"68"x20"h: 4' 6"30"x80"30"x80"28"x80"62"x80"48"x80"84"x80"28"x80"36"x80"192"x82"70"x80"58"x80"28"x80"32"x80"36"x80"AIRCONDITIONER14"x30"h: 4' 4"GAS METERELECTRIC METERCRAWLSPACEACCESSWINE CELLAR @ FINISHED CRAWLSPACE BELOW GARAGE FLOOR3'-0"CLEARANCE3'-0"CLEARANCEA1.0PROJECT DATA, SITE PLAN ANDEXISTING AND DEMO FIRST FLOORPLANvicinity mapcode summary & project dataOWNERDESIGNERproject teamARCHITECTURALA1.0 PROJECT DATA, SITE PLAN, AND EXISTING ANDDEMO FIRST FLOOR PLAN.A2.0 EXISTING AND DEMO SECOND FLOOR AND THIRD FLOOR PLANS.A3.0 PROPOSED FIRST FLOOR PLANSA4.0 PROPOSED SECOND FLOOR PLANSA5.0 PROPOSED THIRD FLOOR PLANSA6.0 DEMO AND NEW ELEVATIONS.A7.0 SECTIONS, DOOR AND WINDOW SCHEDULE ANDDETAIL.C1.0 CALGREEN REQUIREMENTSC2.0 CALGREEN REQUIREMENTsheet indexplumbing notesSU-LING CHEAH1042 EMERALD TERUNION CITY CA 94587(510)377.8802 mainslcdesign1999@gmail.comCONSTRUCTION TYPE: V-B (CBC 602.5=VB & TABLE 601)PLANNING and BUILDING: CITY OF LOS GATOSOCCUPANCY: R3 & U ZONING: 1001 APN: 42442008JURISDICTION:SCOPE OF WORK: FIRST FLOOR2. RECONFIGURE LAUNDRY ROOMSECOND FLOOR1. REMOVE EXISTING DECK.CREATE NEW SUNROOM.3. REMOVE EXISTING KITCHEN. CREATE NEW KITCHEN.4. REMOVE EXISTING BATHROOM AND W.I.C. CREATE NEWBATHROOM.5. REMOVE EXISTING STEP. CREATE NEW W.I.C.THIRD FLOOR6. REMOVE EXISTING OFFICE. CREATE NEW BATHROOMCODES : CBC 2022CPC 2022CEC 2022CMC 20222022 TITLE 24 CALIFORNIA ENERGY CODECRC 2022ADDRESS: 130 VASONA OAKS DR, LOS GATOS, CA 95032general noteselectrical notes1- PERMIT IS REQUIRED FOR ELECTRICAL WORK, MECHANICAL WORK AND PLUMBING WORK.2- WINDOWS MUST PROVIDE. (CBC 1026.2, 1026.3 and 1026.5)A) A MINIMUM 5.7 SQUARE FEET OR CLEAR OPENABLE AREA.B) A MINIMUM CLEAR WIDTH OF 20', MINIMUM CLEAR HEIGHT OF 24".C) A FINISHED SILL HEIGHT NOT MORE THAN 44" ABOVE THE FLOOR.D) DIRECT OPENING TO PUBLIC WAY OR YARD/COURT OPENING TO PUBLIC WAY3- SAFETY GLAZING (TEMPERED GLASS) IS REQUIRED (CBC 2406.3) FOR WINDOWS:A) ADJACENT TO BATHTUBS, SHOWERS, HOT TUBS, WHIRLPOOLS, AND SAUNAS, AND WITHIN 60" OF THEFLOOR;B) WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF DOORS IN THE CLOSED POSITION AND WITHIN 60" OF THEFLOOR;C) WITHIN 18" VERTICALLY AND 36" HORIZONTALLY OF A WALKING SURFACE, WHERE THE INDIVIDUAL PANE ISGREATER THAN 9 FT. AND THE TOP EDGE IS GREATER THAN 36" ABOVE THE FLOOR;D) ADJACENT TO STAIRWAYS, RAMPS, AND LANDINGS, OR WITHIN 5'-0" HORIZONTALLY OF THE BOTTOM OF STAIRWAYS, WHERE THE BOTTOM EDGE IS WITHIN 60" OF THE WALKING SURFACE.1- WALL RECETACLES. ELECTRICAL RECEPTACLES SHALL BE PROVIDED SO THAT NO POINT ALONG THE FLOOR LINE INANY WALL SPACE, 2'-0" OR MORE IN WIDTH, IS MORE THAN 6'-0" FROM OUTLET. FIXED GLAZED PANELS IN EXTERIORWALLS ARE CONSIDERED WALL SPACE. CEC ARTICLE 210-52(a).2- BATHROOM RECEPTACLES. AT LEAST ONE WALL RECEPTACLE SHALL BE INSTALLED IN EACH BATHROOM WITHIN 36"OF THE OUTSIDE EDGE OF THE LAVATORY. CEC ARTICLE 210-52(d).3- OUTDOORS RECEPTACLES. FOR A SINGLE-FAMILY DWELLING AND EACH DWELLING UNIT OF A DUPLEX, AT LEAST ONEELECTRICAL RECEPTACLE ACCESSIBLE AT GRADE LEVEL AND NOT MORE THAN 6'-6' ABOVE GRADE LEVEL SHALL BEINSTALLED AT FRONT AND BACK OF BUILDING. CEC ARTICLE 210-52(e).4- HEIGHT ABOVE FINISHED FLOOR OR WORKING SURFACE. THE CENTER OF 15, 20, AND 30-AMPERE RECEPTACLESSHALL BE INSTALLED NOT LESS THAN 12" ABOVE THE FLOOR OR WORKING SURFACE.CEC ARTICLE 210-50(e), TITLE 24AMENDMENT,5- GROUND-FAULT CIRCUIT-INTERRUPTERS (GFCI). GFCI PROTECTED RECEPTACLES SHALL BE INSTALLED INBATHROOMS, GARAGES, NON-HABITABLE ACCESSORY BUILDING WITH ELECTRICAL POWER, UNFINISHED BASEMENT,OUTDOOR WITH DIRECT ACCESS TO GRADE, ROOF TOPS, AT KITCHEN COUNTERTOPS AND WITHIN 6'-0' OF A WET BARSINK. CEC ARTICLE 210-8.6- WEATHER PROTECTION. ELECTRICAL RECEPTACLES INSTALLED OUTDOORS WHERE EXPOSED TO WEATHER OR INOTHER WET LOCATIONS SHALL BE IN A WEATHERPROOF ENCLOSURE,CEC ARTICLE 410-57.7- LIGHTING. AT LEAST ONE WALL SWITCH-CONTROLLED LIGHT OUTLET IS REQUIRED IN EACH HABITABLE ROOM,BATHROOM, HALLWAY, STAIRWAY, GUEST ROOM, ATTACHED GARAGE AND DETACHED GARAGE WITH ELECTRICALPOWER, AND AT OUTDOOR ENTRANCES. IN HABITABLE ROOMS OTHER THAN KITCHEN AND BATHROOHS ONE OR MORERECEPTACLES CONTROLLED BY A WALL SWITCH ARE PERMITTED. CEC ARTICLE 210-70(a).8-HALLWAY RECEPTACLES. AN ELECTRICAL OUTLET SHALL BE PROVIDED IN EACH HALLWAY OF 10'-0" OR MORE INLENGTH. HALLWAY LENGTH IS AS MEASURED ALONG THE CENTERLINE WITHOUT PASSING THROUGH A DOORWAY. CECARTICLE 210-52(h).9- ALL BRANCH CIRCUITS THAT SUPPLY 125-VOLT, SINGLE PHASE 15 & 20 AMPERE RECEPTACLE AND GFCIPROTECTED OUTLETS INSTALLED IN DWELLING UNITS, SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER(A.F.C.I.) LISTED TO PROTECT THE ENTIRE BRANCH CIRCUIT PER CEC.10- ALL PHONE LINES TO BE (2) CATEGORY 5 TWISTED PAIR LINES & CABLE LINES ARE TO BE HOME RUN TO BOX INRESIDENCE. COORDINATE SYSTEM WITH OWNER.11- LIGHT FIXTURES OVER TUB SHALL BE PROTECTED BY A GFCI & MEET THE FOLLOWING REQUIREMENTS:RECESSED FIXTURES WITH A GLASS OR PLASTIC LENS & NONMETALLIC OR ELECTRICALLY ISOLATED TRIM, & SHALLBE SUITABLE FOR USE IN DAMP LOCATION.12- ALL LIGHTING AS HIGH EFFICACY (I.E. PIN-BASED CFL; PULSE-START MH, HPS, GU-24 SOCKETS OTHER THAN LEDS, LEDLUMINAIRES WITH INTEGRAL SOURCE, ETC.). CEC TABLE 150.0-A13-LEAST ONE FIXTURE IN EACH BATHROOM CONTROLLED BY A VACANCY SENSOR OR OCCUPANCY SENSOR PRO VIDED THEOCCUPANCY SENSOR THAT IS INITIALLY PROGRAMED LIKE A VACANCY SENSOR (MANUAL-ON OPERATION). CEC 150.0{K)2J14-ALL OUTDOOR LIGHTING ATTACHED TO THE BUILDING SHALL HAVE MOTION-SENSOR + PHOTO-CONTROL.15-ALL 125-VOLT 15 & 20 AMPERE RECEPTACLE OUTLETS SHALL BE LISTED TAMPER RESISTANT RECEPTACLES PER CEC406.12.16-BATHROOM EXHAUST FANS SHALL BE SEPARATELY SWITCHED FROM ANY LIGHTING PER TITLE 24 SECTION150.0(k)2B.17-LIGHTING IN GARAGES, LAUNDRY ROOMS, & UTILITY ROOMS SHALL BE HIGH EFFICACY & CONTROLLED BY VACANCYSENSORS PER TITLE 24 SECTION 150.0(k)6.18-SCREW -BASED PERMANENTLY INSTALLED LIGHT FIXTURESMUST CONTAIN SCREW-BASED JAB (JOINT APPENDIX 8)COMPLIANT LAMPS. JAB COMPLIANT LIGHT SOURCES MUST BE MARKED AS "JAS-2019" OR "JAS-2019-E" ("JAS-2019-E"LUM INA IRE S ARE DEEMED APPROPRIATE FOR USE IN ENC LOSED LUMINAIRES). ADVISORY: " JAB-20 16- E"MARKED LUMINAIRES ARE STILL ALLOWED FOR USE THROUGH THE END OF THE 2022 CODE CYCLE. CEC 150.0(K)G19- AMEND THE NOTES TO SPECIFY ALL JAB C O MP LIA NT LIGHT SOURCES IN THE FOLLOWING LOC ATION S ARECONTROLLED BY VACANCY SENSORS OR DIMMERS (EXCEP TIO N CLOSETS LESSTHAN 70 SF AND HALLWAYS). CEC150.0(K)(2K):xxxx1- PROVIDE 24" CLEAR IN FRONT OF TOILET AND 30" MINIMUM WIDE TOILET COMPARTMENT. CBC SECTION 2904, CPCSECTION 408.6.2- PROVIDE MINIMUM 1,024 SQUARE INCH AREA AND 30" DIAMETER IN SHOWER COMPARTMENT. CPC SECTION 412.7.3- WALL COVERINGS IN SHOWERS AND TUBS TO BE CEMENT PLASTER, TILE, OR EQUAL TO 72" ABOVE DRAIN.ENCLOSURES MUST BE OF APPROVED SAFETY GLAZING AND DOORS MUST SWING OUT OF SHOWERS. WINDOWS INENCLOSURE WALLS SHALL BE LABELED SAFETY GLAZING WHEN LESS THAN 60" ABOVE THE DRAIN. CBC SECTION 2512,CPC SECTION 412.7.4- PROVIDE A 12" MINIMUM ACCESS PANEL TO BATHTUB TRAP CONNECTION UNLESS PLUMBING IS WITHOUT SLIPJOINTS. CPC SECTION 405.2.5- PROVIDE LOW FLOW TOILETS (1.28 GALLON PER FLUSH), SHOWERHEADS (1.8 GPM) AND FAUCETS: KITCHEN: 1.8GPM; LAVATORY: 1.2 GPM. CPC SECTION 402.6- SHOWER AND TUB-SHOWER COMBINATIONS SHALL HAVE INDIVIDUAL CONTROL VALVES OF THE PRESSUREBALANCE OR THE THERMOSTATIC MIXING VALVE TYPE. CPC 408.31EXISTING USE: SINGLE FAMILY HOME - NON SPRINKLERED - ONE STORYLOT SIZE: 1,977 S.F.existing and demo first floor planSCALE: 3/16" = 1'-0"SITEsite plan legendPROPERTY LINEREMODEL AREA OF EXISTING HOUSEgeneral notes1# description datedate354plan checkclient reviewrevision history2dateconstructionbiddingarchproj projmgrnumprojscaledrawing release statusconsultantconsultantAS NOTEDsheetnumber4.19.2024______ResidenceRemodeling & Addition130 Vasona Oaks Dr,Los Gatos, CA 950321. This sheet is part of a set and is not to be used alone.2. This sheet is not to be used for construction unless thedesigner's signature appear on drawings and statusbox indcates drawings have been released forconstruction.3. These plans and prints thereof, as instruments ofservice, are owned by the designer and are for use onthis project only. Reproduction and/or distributionwithout the prior written consent of the designer isforbidden.4. Copyright Su-Ling Slaton, 2025planning comments response 6.9.2025planning comments resp. 6.19.2025(E) WALL TO REMAINlegenddemo sheet notes##(E) WALL, DOORS AND WINDOWS TO REMOVE--DETAIL NUMBERSHEET NUMBEREXTERIOR ELEVATION REFERENCE TAGsite plan with new floor planSCALE: 1/4" = 1'-0"2NNNBGTYP.KLMA. REMOVE EXISTING DOORS (SHOWN DASHED).B. REMOVE EXISTING DOOR (SHOWN DASHED). INFILL WITH NEW WALL AND MATCH TO ALIGN WITH EXISTINGADJACENT.C. REMOVE EXISTING DOOR (SHOWN DASHED). REPLACE WITH NEW DOOR.D. REMOVE EXITING WINDOW. (SHOWN DASHED).E. REMOVE EXISTING WINDOWS (SHOWN DASHED). REPLACE WITH NEW DOOR.F. REMOVE EXISTING WINDOWS (SHOWN DASHED). FILLED WITH NEW WALL.G. REMOVE THIS PORTION OF EXISTING WALL.H. REMOVE (E) KITCHEN UPPER & LOWER CABINET, COUNTERTOP, FAUCET, STOVE, REFRIGERATOR,DISHWASHER, DISPOSAL, & OVEN, CAP & SALVAGE (E) PLUMBING & GAS LINE FOR NEW APPLIANCES, SEEPROPOSED FLOOR PLAN FOR NEW LOCATION.I. REMOVE PLUMBING FIXTURE AND ACCESSORIES. CAP PLUMBING LINES BEHIND WALLS/UNDER FLOOR.J. REMOVE ATTIC ACCESS (SHOWN DASHED).K. REMOVE WATER HEATER (SHOWN DASHED).L. REMOVE AIR CONDITIONER.M. REMOVE EXISTING POST. SEE S.S.D.N. REMOVE EXISTING STEP.O. REMOVE DECK (SHOWN DASHED).P. (E) SKYLIGHT TO REMAIN.Q. (E) CRAWL SPACE ACCESS TO REMAIN.QA3.01NEW PROPOSEDPLANFIRST FLOOR:A. (E) HOUSE: 678 S.F.B. AREA OF WORK: 126 S.F.SECOND FLOOR:A. (E) HOUSE: 1087 S.F.B. AREA OF WORK: 786 S.F.C. NEW ADDITION: 91 S.F.MEZZANINE/THIRD FLOOR:A. (E) HOUSE: 172 S.F. - 64 S.F. = 108 S.F.B. AREA OF WORK: 108 S.F.C. NEW ADDITION-INTERIOR 220 S.F.EXISTING GARAGE:A: EXISTING GARAGE:464 S.FB. AREA OF WORK: 40 S.F.DEFERRED SUNROOM: 231 S.F.EXISTING COVERED PATIO: 148 S.F.NEW COVERED PATIO: 173 S.F.IEXISTING PROPOSEDLOT SIZE1,977 S.F. 1,977 S.F.LOT COVERAGE66% 73.40%FIRST FLOOR LIVING AREA S.F.:678 S.F. 0 S.F.SECOND FLOOR LIVING AREA S.F.:1087 S.F.322 S.F. ADDITION= 1409THIRD FLOOR LIVING AREA S.F.:236 S.F.329 S.F.ADDITIONTOTAL LIVING AREA S.F.2001 s.f. 2416 S.F.FIRST FLOOR PATIO148 s.f.173 s.f.ADDITION +148 S.F. =321 S.F.FAR - HOME101.21% 122.20%FAR - GARAGE23.30% NO CHANGELOT COVERAGE1290 S.F. 1463 S.F.PROJECT DATA##EXHIBIT 9 16'-418"16'-1034"1'-914"3'-078"18'-814"21'-314"4'-1078"11'-158"13'-918"6'-3"13'-418"14'-218"36'-912"3'-1078"2'-258"13'-9"16'-11"5"41'-258"14'-218"7'-034"20'-134"ELECTRICPANEL(E) BEDROOM8'-0"(E)(E) BEDROOM13' 9 1/8" X 11' 1 5/8"8'-0"(E)(E) GARAGE20' 1 3/4" X 21' 3 1/4"8'-10"(E)(E) ENTRY6' 11 1/2" X 4' 10"8'-0"(E)94"x36"h: 3' 4"68"x20"h: 4' 6"30"x80"28"x80"84"x80"28"x80"36"x80"192"x82"70"x80"58"x80"28"x80"32"x80"36"x80"14"x30"h: 4' 4"GAS METERELECTRIC METERCRAWLSPACEACCESS41'-258"7'-012"32"x80"72"x80"RECONFLAUNDRYRM.3'-018"2'-0"9'-518"PREFABDUMBWAITER11'-0"(N)TANKLESSW.H.WINE CELLAR @ FINISHED CRAWLSPACE BELOW GARAGE FLOOR(N)ACD4D230"x80"2'-714"3'-6"D3 (N)WATERSOFTENER(N) COVERED PATIO1'-6"1'-6"24"CLRRECONFBATHROOMWATERHEATERELECTRICPANEL(E) BEDROOM13' 4 1/8" X 16' 4 1/8"8'-0"(E)(E) BEDROOM13' 9 1/8" X 11' 1 5/8"8'-0"(E)(E) BATH10' 4 7/8" X 4' 10 7/8"8'-0"(E)(E) GARAGE20' 1 3/4" X 21' 3 1/4"8'-10"(E)(E) ENTRY6' 11 1/2" X 4' 10"8'-0"(E)94"x36"h: 3' 4"68"x20"h: 4' 6"30"x80"30"x80"28"x80"62"x80"48"x80"84"x80"28"x80"36"x80"192"x82"70"x80"58"x80"28"x80"32"x80"36"x80"AIRCONDITIONER14"x30"h: 4' 4"GAS METERELECTRIC METERCRAWLSPACEACCESSWINE CELLAR @ FINISHED CRAWLSPACE BELOW GARAGE FLOORexisting and demo first floor planSCALE: 1/4" = 1'-0"1NA2.0EXISTING AND DEMO AND NEWPROPOSED FIRST FLOOR PLANS(E) STUD WALL TO REMAINlegend(E) WALL, DOORS AND WINDOWS TO REMOVE1# description datedate354plan checkclient reviewrevision history2dateconstructionbiddingarchproj projmgrnumprojscaledrawing release statusconsultantconsultantAS NOTEDsheetnumber4.19.2024Ken MacDonald'sResidenceApplicationPD-25-002Remodeling & Addition130 Vasona Oaks Dr,Los Gatos, CA 95032general notes1. This sheet is part of a set and is not to be used alone.2. This sheet is not to be used for construction unless thedesigner's signature appear on drawings and status boxindicates drawings have been released for construction.3. These plans and prints thereof, as instruments ofservice, are owned by the designer and are for use onthis project only. Reproduction and/or distribution withoutthe prior written consent of the designer is forbidden.4. Copyright Slcdesign, 2025xDo not scale or measure plan set.xAll vendors shall measure as builts/current framingconditions prior to casework/cabinet fabricationdisclaimernew proposed first floor plan2SCALE: 1/4" = 1'-0"NBGTYP.KLMA. REMOVE EXISTING DOORS (SHOWN DASHED).B. REMOVE EXISTING DOOR (SHOWN DASHED). INFILL WITH NEW WALL AND MATCH TO ALIGN WITH EXISTINGADJACENT.C. REMOVE EXISTING DOOR (SHOWN DASHED). REPLACE WITH NEW DOOR.D. REMOVE EXITING WINDOW. (SHOWN DASHED).E. REMOVE EXISTING WINDOWS (SHOWN DASHED). REPLACE WITH NEW DOOR.F. REMOVE EXISTING WINDOWS (SHOWN DASHED). FILLED WITH NEW WALL.G. REMOVE THIS PORTION OF EXISTING WALL.H. REMOVE (E) KITCHEN UPPER & LOWER CABINET, COUNTERTOP, FAUCET, STOVE, REFRIGERATOR,DISHWASHER, DISPOSAL, & OVEN, CAP & SALVAGE (E) PLUMBING & GAS LINE FOR NEW APPLIANCES, SEEPROPOSED FLOOR PLAN FOR NEW LOCATION.I. REMOVE PLUMBING FIXTURE AND ACCESSORIES. CAP PLUMBING LINES BEHIND WALLS/UNDER FLOOR.J. REMOVE ATTIC ACCESS (SHOWN DASHED).K. REMOVE WATER HEATER (SHOWN DASHED).L. REMOVE AIR CONDITIONER.M. REMOVE EXISTING POST. SEE S.S.D.N. REMOVE EXISTING STEP.O. REMOVE DECK (SHOWN DASHED).P. (E) SKYLIGHT TO REMAIN.Q. (E) CRAWL SPACE ACCESS TO REMAIN.demo sheet notes##8A7.06A7.05A7.07A7.01A8.01262027QA2.02NEW PROPOSEDPLAN292A8.0I161718192024--DETAIL NUMBERSHEET NUMBEREXTERIOR ELEVATION REFERENCE TAG(N) 2x STUD WALL -EXTERIOR WALL TO RECEIVE 2X6 WITH R-13 BATT. INSULATION SEETITLE 24 FOR MORE INFO.1. NEW RELOCATED WASHER. PROVIDE POWER2. PROVIDE WATER HAMMER ARRESTORS AT ALL APPLIANCES THAT HAVE QUICK-ACTING VALVES (I.E. DISHWASHER HOT WATER LINEAND THE HOT/COLD WATER LINES FOR THE CLOTHES WASHER.) 2022CPC 609.103. PROVIDE NEW DISHWASHER. PROVIDE POWER AND PLUMBING. ON THE DISCHARGE SIDE OF THE DISHWASHER PROVIDE A LISTEDAIR GAP FITTING. LISTED AIR GAPS SHALL BE INSTALLED WITH THE FLOOD LEVEL MARKING AT OR ABOVE THE FLOOD LEVEL OF THESINK OR DRAIN BOARD WHICHEVER IS HIGHER PER CPC SECTION 807.3.4. INSTALLATION OF A DEDICATED FUEL SHUT OFF VALVE SHALL BE WITHIN 6'-0" OF THE GAS APPLIANCE IT SERVES. CPC 230.79.EARTHQUAKE-ACTUATED GAS SHUTOFF VALVES DESIGNED TO AUTOMATICALLY SHUT OFF THE GAS AT THE LOCATION OF THEVALVE IN THE EVENT OF A SEISMIC DISTURBANCE AND CERTIFIED BY THE STATED ARCHITECT AS CONFORMING TO CALIFORNIACODE OF REGULATIONS, TITLE 24, PART 12, CHAPTER 12É16É1, SHALL BE INSTALLED IN ALL NEW BUILDINGS AND IN EXISTINGBUILDINGS THAT UNDERGO ALTERATIONS OR ADDITIONS THAT EXCEED $10,000.5. PROVIDE NEW GAS COOKING RANGE (PROVIDE POWER) WITH NEW EXHAUST HOOD (PROVIDE POWER) WITH A MIN. VENTILATIONEXHAUST RATE OF 100 CFM. HOUSEHOLD COOKING APPLIANCES SHALL HAVE A VERTICAL CLEARANCE ABOVE THE COOKING TOPOF NOT LESS THAN THIRTY - 30" INCHES TO COMBUSTIBLE MATERIAL OR METAL CABINETS, EXCEPT WHERE 24 INCHES IS ALLOWEDPER CODE OR MANUFACTURER'S SPECIFICATION. CMC 920.3.2.6. RANGE HOODS SHALL BE PERMITTED TO BE CORD-AND-PLUG-CONNECTED WITH A FLEXIBLE COURT IDENTIFIED AS SUITABLE FORUSE ON RANGE HOODS IN THE INSTALLATION INSTRUCTIONS OF THE APPLIANCE MANUFACTURER, WHERE ALL THE FOLLOWINGCONDITIONS ARE MET: THE FLEXIBLE CORD IS TERMINATED WITH A GROUNDING-TYPE ATTACHMENT PLUG. THE LENGTH OF THECORD IS 18 INCHES TO 4 FEET. RECEPTACLES ARE LOCATED TO PROTECT AGAINST PHYSICAL DAMAGE TO THE FLEXIBLE CORD.THE RECEPTACLES IS ACCESSIBLE. THE RECEPTACLE IS SUPPLIED BY AN INDIVIDUAL BRANCH CIRCUIT.7. IF OCCURS ELECTRIC STOVES AND OVENS SHALL BE SUPPLIED WITH 40- OR 50-AMP BRANCH CIRCUIT.8. PROVIDE NEW SINK WITH CALGREEN COMPLIANT FAUCET WITH NEW GARBAGE DISPOSAL (PROVIDE POWER).9. NEW REFRIGERATOR/ICE MAKER/WINE COOLER (PROVIDE POWER AND ICE MAKER OUTLET BOX AND CONNECT).10. NEW SOLID COUNTER TOP WITH UPPER AND LOWER CABINETS.11. COUNTERTOP AND WHERE THE COUNTERTOP DOES NOT EXTEND MORE THAN 6 INCHES BEYOND ITS BASE.12. NEW SOLID SURFACE COUNTER KITCHEN ISLAND AND BAR COUNTER WITH BASE CABINET.13. COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER SHALL PROTECT ALL RECEPTACLES IN ALL BEDROOMS, DINING ROOMS,LIVING ROOMS, PARLORS, LIBRARIES, DENS SUNROOMS, RECREATION ROOMS, CLOSETS, KITCHENS. LAUNDRY AREAS. HALLWAYSOR SIMILAR ROOMS OR AREAS WITH BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE-PHASE, 15 AND 20-AMPERE RECEPTACLEOUTLETS, AND BE READILY ACCESSIBLE. 2022 CEC SECTION 210.1214. TWO 20-AMP GFCI PROTECTED CIRCUITS WILL BE PROVIDED IN THE KITCHEN COUNTER AND ISLAND OUTLETS AND SHALL COMPLYWITH ART. 210.52 (C) (5) EXCEPTION TO (5) CEC 202215. LIGHTING INTEGRAL TO EXHAUST FANS SHALL BE CONTROLLED SEPARATELY FROM THE EXHAUST FANS. 150.0 (K) 28. LIGHTINGSHALL HAVE VACANCY SENSOR. EXHAUST FAN SHALL BE 50 CFM MIN.16. PROVIDE WATER CLOSETS TO BE MAX. 1.28 GAL. PER FLUSH.17. SHOWER/TUB W/ FULL HEIGHT TILE WALLS & TEMPERED GLASS ENCLOSURE. USE BITUTHANE 4,000 WATERPROOFING MEMBRANEOVER 1/2" WONDER BOARD & WALLS, CEILING, & FLOOR.18. NEW SOLID SURFACE (NON-SLIP RESISTANT) SHOWER PAN AND WALLS19. PROVIDE SHOWER FINISHED TO 72" ABOVE DRAIN. PROVIDE PRESSURE OR THERMOSTATIC MIXING VALUE @ SHOWER ANDJACUZZI/TUB, WHICH LIMITS WATER TEMPERATURE TO 120°F. SHOWER HEAD SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60PSI.20. NEW SINK AND FAUCET. PROVIDE FAUCET TO BE MAX 1.2 CMP AT 60 PSI.METERING FAUCETS SHALL NOT EXCEED 0.2 GALLONS PERMETERING CYCLE.21. WINDOW MODIFICATIONS: REPLACEMENT AND NEW WINDOWS: SHALL HAVE A U-FACTOR EQUAL TO 0.3022. PROVIDE NEW COMBO UNIT SMOKE DETECTOR AND CARBON MONOXIDE DETECTOR W/BATTERY BACK-UP IN HALLWAY.23. PROVIDE NEW 24" X 48" FLAT PROFILE SKYLIGHT.24. PROVIDE NEW TANKLESS WATER HEATER.25. NEW MIN. 36"x24" ATTIC ACCESS26. NEW PREFABRICATED STAIRS.27. NEW P.T. POSTS ON CONC. BASE 2" ABOVE FINISHED GRADE (TYP.)28. NEW DECKING OVER FRAMING. S.S.D. FOR FRAMING DETAILS.29. NEW AIR CONDITIONER.new sheet notes##KITCHEN GENERAL NOTES (2022 CBC REQUIREMENTS):WATER CONSERVING PLUMBING FIXTURES REQUIREMENTS:• KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE. FLOWMAY TEMPORARILY INCREASE TO 2.2 GALLONS PER MINUTE, BUT MUST DEFAULT TO A MAXIMUM OF 1.8GALLONS PER MINUTE [CGBSC 4.303.1.4.4]• PRIOR TO FINAL INSPECTION ALL NON-COMPLIANT PLUMBING FIXTURES SHALL BE UPGRADEDWITH WATER-CONSERVING FIXTURES AS REQUIRED BY CIVIL CODE 1101.1. A COMPLETED AND SIGNEDCERTIFICATE OF COMPLIANCE SHALL BE PROVIDED TO THE BUILDING INSPECTOR.ELECTRICAL REQUIREMENTS:• RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL COUNTERTOPOR WORK SURFACE IS MORE THAN 24 INCHES FROM A RECEPTACLE IN THAT SPACE. [CEC 210.52(C)(1)]• RECEPTACLE OUTLETS SHALL BE INSTALLED AT EACH KITCHEN COUNTERTOP AND WORKSURFACE THAT IS 12 INCHES OR WIDER. [CEC 210.52(C)(1)]• AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH ISLAND OR PENINSULARCOUNTER SPACE WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12INCHES OR GREATER. [CEC 210-52(C)(2) AND 210.52(C)(3)]• ALL ELECTRICAL OUTLETS SERVING KITCHEN COUNTERTOPS AND DISHWASHERS SHALL BE GFCIPROTECTED. GROUND FAULT CIRCUIT INTERRUPTERS SHALL BE LOCATED IN A READILY ACCESSIBLELOCATION. [CEC 210.8(A)(D)]• AT LEAST TWO SEPARATE 20-AMPERE BRANCH CIRCUITS SHALL BE PROVIDED FOR SMALLKITCHEN APPLIANCES. THESE CIRCUITS ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETSONLY AND CANNOT SERVE DISHWASHER, MICROWAVE, RANGE HOOD, GARBAGE DISPOSAL, ETC.[CEC 210.11(C)(1) AND 210.52(B)(3)]• ALL ADDED/REPLACED RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES ANDSHALL BE ARC FAULT PROTECTED. [CEC 406.12]2022 BATHROOM REMODEL REQUIREMENTS:1. PROVIDE WATERPROOFED MATERIAL AT SHOWER WALLS.2. ALL RECEPTACLES SHALL BE GFCI PROTECTED AND CONNECTED TO A DEDICATED 15 AND 20 AMPS CIRCUIT ÂCEC 210.8Ã3. ALL HARDWIRED LIGHTING SHALL BE HIGH EFFICACY. ÂCA ENERGY EFF. STANDARDS, SECTION 150(K))4. EXHAUST FANS ARE REQUIRED IN ALL BATHROOMS, EVEN IF AN OPERABLE WINDOW IS INSTALLED. CRC 303.3\5. EXHAUST FANS AND LIGHTING SHALL HAVE SEPARATE CONTROL SWITCHES, (EVEN IF A COMBINATION UNIT IS INSTALLED). THEEXHAUST FAN MAY NEED TO BE SUPPLIED BY A GFCI PROTECTED CIRCUIT BASED ON THE MANUFACTURER’FS REQUIREMENTS. CEC150.0 (K)(2B)6. EXHAUST FANS SHALL TERMINATE A MINIMUM OF 3’F FROM PROPERTY LINE AND 3’F FROM OPENINGS INTO A BUILDING. (CMC502.2.1)7. EXHAUST FANS AT SHOWER SHALL BE LISTED FOR WET LOCATION AND SHALL BE GFCI PROTECTED. CEC 210.88. SHOWER ENCLOSURE DOORS SHALL OPEN OUTWARD AND MAINTAIN 22”H CLEARANCE CPC 408.59. SHOWER COMPARTMENT SHALL BE A MINIMUM 1,024 SQUARE INCHES ENCOMPASSING A 30”H CIRCLE. CPC 408.610. WATER CLOSETS (MAXIMUM 1.28 GPMÃ SHALL BE CLEAR 30 INCHES WIDE 15 INCHES ON CENTER) AND 24 INCHES IN FRONT. CPC402.511. SHOWER HEADS (MAXIMUM 1.8 GPM CPC 408.2 & FAUCETS (MAXIMUM 1.2 GPM CPC 407.2)12. BATHTUB/WHIRLPOOLS AND SHOWER VALVES SHALL BE APPROVED PRESSURE-BALANCED OR THERMOSTATIC MIXING TYPEADJUSTED TO A MAXIMUM OF 120 DEGREES. CPC 408.3WINDOW MODIFICATIONS: REPLACEMENT AND NEW WINDOWS:1. SHALL HAVE A U-FACTOR EQUAL TO 0.30 OR LOWER. EXCEPTIONS:REPLACEMENT SKYLIGHTS, OR NEW SKYLIGHTS UP TO 16 SQUARE FEET, MAY HAVE A U-FACTOR OF 0.55. WHEN 75 SQUARE FEET OR LESS OF FENESTRATION IS REPLACED WINDOWS MAY HAVE A U-FACTOR OF 0.40. [CENC 150.2(B) TABLE 150.1-A]2. FOR WINDOW MODIFICATIONS IN THE HILLSIDE FIRES ZONES 2 AND 3 REFER TO WINDOW ANDDOOR CODE COMPLIANCE CHECKLISTVENTILATION REQUIREMENTS:• TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS SHALL BE AT LEAST 3 FEET FROM PROPERTYLINE AND FROM OPENINGS INTO THE BUILDING, AND 10 FEET FROM A FORCED AIR INLET.[CMC 502.2.1]• WHOLE-BUILDING VENTILATION: KITCHENS REQUIRE VENTILATION AIR FLOW AT 100 CUBIC FEETPER MINUTE OR MORE FOR INTERMEDIATE SYSTEMS OR 5 AIR CHANGES PER HOUR FOR CONTINUOUS SYSTEMS. [ASHRAE 62.2]BUILDING ENVELOPE MODIFICATIONS:EXTERIOR WALL, FLOOR AND ROOF FRAMING SPACES OPENED UP DURING THE COURSE OF REMODELSHALL BE INSULATED. R-13 (2X4 WALL), R-20 (2X6 WALL), R-19 (FLOOR), AND R-19 (ATTIC/ROOF)INSULATION. [CENC 150.0(A)(C)(D)]LIGHTING REQUIREMENTS:• ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY. [CENC 150.0 TABLE 150.0-A]• UNDER CABINET LIGHTING SHALL BE CONTROLLED SEPARATELY FROM CEILING INSTALLEDLIGHTING SUCH THAT ONE CAN BE TURNED ON WITHOUT THE OTHER. [CENC 150.0(2)(K)]• LUMINARIES RECESSED INTO INSULATED CEILINGS:(A) SHALL BE LISTED FOR ZERO CLEARANCE INSULATION COVER (IC RATED);(B) SHALL INCLUDE A LABEL CERTIFYING AIR TIGHT (AT) WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS;(C) SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINARY HOUSING AND CEILING;(D) IF RECESSED LIGHTS ARE EQUIPPED WITH BALLASTS, SHALL ALLOW BALLAST MAINTENANCE ANDREPLACEMENT WITHOUT REQUIRING CUTTING OF HOLES IN THE CEILING; AND(E) SHALL NOT CONTAIN SCREW BASE SOCKETS. [CEES SEC.150(K)12].SMOKE ALARMS: DWELLINGS ARE TO BE EQUIPPED WITH SMOKE ALARMS INSTALLED IN THE FOLLOWING LOCATIONS: [CRC 314.4]• IN EACH EXISTING SLEEPING ROOM.• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.• ON EACH STORY INCLUDING BASEMENTS AND HABITABLE ATTICS, NOT INCLUDING CRAWLSPACES AND UNINHABITABLE ATTICS.• INSTALLED NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS WOULDPREVENT PLACEMENT OF A SMOKE ALARM REQUIRED BY CRC R314.3(4).CARBON MONOXIDE ALARMS: DWELLINGS THAT HAVE ATTACHED GARAGES WITH AN OPENING THAT COMMUNICATES WITH THE DWELLING UNIT, OR FUEL BURNINGAPPLIANCES, OR FIRE PLACE ARE TO BE EQUIPPED WITH CARBON MONOXIDE ALARMS INSTALLED INTHE FOLLOWING LOCATIONS: [CRC 315.3]• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.• ON EVERY OCCUPIABLE LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS.• WHERE A FUEL-BURNING APPLIANCE IS LOCATED WITHIN A BEDROOM OR ITS ATTACHED BATHROOM. A CARBON MONOXIDE ALARM SHALL BE INSTALLED WITHIN THEBEDROOM.ALARM INTERCONNECTION AND POWER: SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INTERCONNECTED SUCH THAT ACTIVATION OF ONE ALARM WILLACTIVATE ALL OF THE ALARMS AND SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING. EXCEPTION: WHERE REPAIRS OR ALTERATIONS TO EXISTINGBUILDINGS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHES AND THERE IS NO ACCESS BY MEANS OF ATTIC, BASEMENT OR CRAWL SPACE. [CRC 314.4 AND§314.6]SMOKE AND CARBON MONOXIDE DETECTORWHEN ALTERATIONS,REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, THE INDIVIDUAL DWELLINGUNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. [R314.2.2]4A7.02A7.01A7.03A7.011 (E) LIVING ROOM / DINNING ROOM18' 0 1/2" X 23' 8 3/4"17'-0"(E)(E) DECK13' 8 1/8" X 11' 0 3/8"(E) KITCHEN9' 0 3/4" X 16' 7 3/4"8'-0"(E)(E) W.I.C.6' 4 1/8" X 6' 11 5/8"8'-0"(E)(E) BATH6' 4 1/7" X 11' 4 5/8"8'-0"(E)(E) BEDROOM13' 3 1/2" X 18' 0"15'-0"(E)94"x58"h: 1' 10"58"x58"h: 1' 10"36"x76"h: 3' 2"34"x58"h: 1' 10"46"x40"h: 3' 4"52"x40"h: 3' 2"28"x80"28"x80"28"x80"28"x80"70"x80"36"x80"28"x80"36"x80"70"x40"h: 3' 4"ATTICACCESSSKYLIGHT8'-2"(E)10'-6"(E)ATTICACCESS12'-0"(E)8'-6"(E)14'-6"(E)8'-0"(E)11'-6"(E)UPDN.SKYLIGHTSKYLIGHT14'-158"7'-6"24'-378"13'-312"6'-414"16'-734"36'-7"7'-358"13'-812"5'-738"7'-418"37'-438"(E) BEDROOM34"x58"h: 1' 10"46"x40"h: 3' 4"70"x40"h: 3' 4"SKYLIGHT8'-6"(E)11'-6"(E)UPDN.UP9'-0"(N) CLG(N) W.I.C.9'-0"(N) CLG30"x80"FRIDGE10'-5"PANTRYwetbar areawinefridgeSKYLIGHTSKYLIGHTPREFABDUMBWAITER30"x80"makeup30"x80"3'-1"9'-314"3'-5"2'-0"3'-618"8'-0"6'-234"3'-6"2'-0"3'-0"30"x80"4'-238"5'-0"14'-018"7'-118"13'-6"4'-5"2'-0"6'-258"4'-0"3'-0"D / WNEW EXTENDED DECK UP TO 5 FEETFROM PROPERTY LINE WILL NEED TOHAVE HEAVY TIMBER (1 HOUR FIRERATING)SO IT IS BETTER TO REPLACE THEENTIRE DECK WITH THE SAMEMATERIAL.(N) ATTICACCESSW/PULLDOWNLADDER2'-6"10'-412"ADDITIONEXISTING12'-818"17'-258"6'-318"(N) SUNROOMD1D1D3D3D3D31'-3"5'-6"13'-312"(N) BATHROOM(N) BATHROOM192"x80"(N) FOLDING DOORSTEMPERED-5 EQ. PANELS192"x80"(N) FOLDING DOORSTEMPERED EQ. PANELS30"x80"D3existing and demo second floor planA3.0EXISTING AND DEMO AND NEWPROPOSED SECOND FLOORPLANS1# description datedate354plan checkclient reviewrevision history2dateconstructionbiddingarchproj projmgrnumprojscaledrawing release statusconsultantconsultantAS NOTEDsheetnumber4.19.2024Ken MacDonald'sResidenceApplicationPD-25-002Remodeling & Addition130 Vasona Oaks Dr,Los Gatos, CA 95032general notes1. This sheet is part of a set and is not to be used alone.2. This sheet is not to be used for construction unless thedesigner's signature appear on drawings and status boxindicates drawings have been released for construction.3. These plans and prints thereof, as instruments ofservice, are owned by the designer and are for use onthis project only. Reproduction and/or distribution withoutthe prior written consent of the designer is forbidden.4. Copyright Slcdesign, 2025xDo not scale or measure plan set.xAll vendors shall measure as builts/current framingconditions prior to casework/cabinet fabricationdisclaimernew proposed second floor plan1SCALE: 1/4" = 1'-0"2SCALE: 1/4" = 1'-0"NNATYP.CDFEGTYP.GTYP.ATYP.HIIJJPPNO4A7.02A7.01A7.03A7.08A7.06A7.05A7.07A7.01A8.0234567891011121314161617181920252628WINDOW MODIFICATIONS: REPLACEMENT AND NEW WINDOWS:1. SHALL HAVE A U-FACTOR EQUAL TO 0.30 OR LOWER. EXCEPTIONS:REPLACEMENT SKYLIGHTS, OR NEW SKYLIGHTS UP TO 16 SQUARE FEET, MAY HAVE A U-FACTOR OF 0.55. WHEN 75 SQUARE FEET OR LESS OF FENESTRATION IS REPLACED WINDOWS MAY HAVE A U-FACTOR OF 0.40. [CENC 150.2(B) TABLE 150.1-A]2. FOR WINDOW MODIFICATIONS IN THE HILLSIDE FIRES ZONES 2 AND 3 REFER TO WINDOW ANDDOOR CODE COMPLIANCE CHECKLISTVENTILATION REQUIREMENTS:• TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS SHALL BE AT LEAST 3 FEET FROM PROPERTYLINE AND FROM OPENINGS INTO THE BUILDING, AND 10 FEET FROM A FORCED AIR INLET.[CMC 502.2.1]• WHOLE-BUILDING VENTILATION: KITCHENS REQUIRE VENTILATION AIR FLOW AT 100 CUBIC FEETPER MINUTE OR MORE FOR INTERMEDIATE SYSTEMS OR 5 AIR CHANGES PER HOUR FOR CONTINUOUS SYSTEMS. [ASHRAE 62.2]BUILDING ENVELOPE MODIFICATIONS:EXTERIOR WALL, FLOOR AND ROOF FRAMING SPACES OPENED UP DURING THE COURSE OF REMODELSHALL BE INSULATED. R-13 (2X4 WALL), R-20 (2X6 WALL), R-19 (FLOOR), AND R-19 (ATTIC/ROOF)INSULATION. [CENC 150.0(A)(C)(D)]LIGHTING REQUIREMENTS:• ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY. [CENC 150.0 TABLE 150.0-A]• UNDER CABINET LIGHTING SHALL BE CONTROLLED SEPARATELY FROM CEILING INSTALLEDLIGHTING SUCH THAT ONE CAN BE TURNED ON WITHOUT THE OTHER. [CENC 150.0(2)(K)]• LUMINARIES RECESSED INTO INSULATED CEILINGS:(A) SHALL BE LISTED FOR ZERO CLEARANCE INSULATION COVER (IC RATED);(B) SHALL INCLUDE A LABEL CERTIFYING AIR TIGHT (AT) WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS;(C) SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINARY HOUSING AND CEILING;(D) IF RECESSED LIGHTS ARE EQUIPPED WITH BALLASTS, SHALL ALLOW BALLAST MAINTENANCE ANDREPLACEMENT WITHOUT REQUIRING CUTTING OF HOLES IN THE CEILING; AND(E) SHALL NOT CONTAIN SCREW BASE SOCKETS. [CEES SEC.150(K)12].SMOKE ALARMS: DWELLINGS ARE TO BE EQUIPPED WITH SMOKE ALARMS INSTALLED IN THE FOLLOWING LOCATIONS: [CRC 314.4]• IN EACH EXISTING SLEEPING ROOM.• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.• ON EACH STORY INCLUDING BASEMENTS AND HABITABLE ATTICS, NOT INCLUDING CRAWLSPACES AND UNINHABITABLE ATTICS.• INSTALLED NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS WOULDPREVENT PLACEMENT OF A SMOKE ALARM REQUIRED BY CRC R314.3(4).CARBON MONOXIDE ALARMS: DWELLINGS THAT HAVE ATTACHED GARAGES WITH AN OPENING THAT COMMUNICATES WITH THE DWELLING UNIT, OR FUEL BURNINGAPPLIANCES, OR FIRE PLACE ARE TO BE EQUIPPED WITH CARBON MONOXIDE ALARMS INSTALLED INTHE FOLLOWING LOCATIONS: [CRC 315.3]• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.• ON EVERY OCCUPIABLE LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS.• WHERE A FUEL-BURNING APPLIANCE IS LOCATED WITHIN A BEDROOM OR ITS ATTACHED BATHROOM. A CARBON MONOXIDE ALARM SHALL BE INSTALLED WITHIN THEBEDROOM.ALARM INTERCONNECTION AND POWER: SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INTERCONNECTED SUCH THAT ACTIVATION OF ONE ALARM WILLACTIVATE ALL OF THE ALARMS AND SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING. EXCEPTION: WHERE REPAIRS OR ALTERATIONS TO EXISTINGBUILDINGS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHES AND THERE IS NO ACCESS BY MEANS OF ATTIC, BASEMENT OR CRAWL SPACE. [CRC 314.4 AND§314.6]SMOKE AND CARBON MONOXIDE DETECTORWHEN ALTERATIONS,REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, THE INDIVIDUAL DWELLINGUNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. [R314.2.2]A3.02NEW PROPOSEDPLAN17181920202A8.0(E) STUD WALL TO REMAINlegend(E) WALL, DOORS AND WINDOWS TO REMOVEA. REMOVE EXISTING DOORS (SHOWN DASHED).B. REMOVE EXISTING DOOR (SHOWN DASHED). INFILL WITH NEW WALL AND MATCH TO ALIGN WITH EXISTINGADJACENT.C. REMOVE EXISTING DOOR (SHOWN DASHED). REPLACE WITH NEW DOOR.D. REMOVE EXITING WINDOW. (SHOWN DASHED).E. REMOVE EXISTING WINDOWS (SHOWN DASHED). REPLACE WITH NEW DOOR.F. REMOVE EXISTING WINDOWS (SHOWN DASHED). FILLED WITH NEW WALL.G. REMOVE THIS PORTION OF EXISTING WALL.H. REMOVE (E) KITCHEN UPPER & LOWER CABINET, COUNTERTOP, FAUCET, STOVE, REFRIGERATOR,DISHWASHER, DISPOSAL, & OVEN, CAP & SALVAGE (E) PLUMBING & GAS LINE FOR NEW APPLIANCES, SEEPROPOSED FLOOR PLAN FOR NEW LOCATION.I. REMOVE PLUMBING FIXTURE AND ACCESSORIES. CAP PLUMBING LINES BEHIND WALLS/UNDER FLOOR.J. REMOVE ATTIC ACCESS (SHOWN DASHED).K. REMOVE WATER HEATER (SHOWN DASHED).L. REMOVE AIR CONDITIONER.M. REMOVE EXISTING POST. SEE S.S.D.N. REMOVE EXISTING STEP.O. REMOVE DECK (SHOWN DASHED).P. (E) SKYLIGHT TO REMAIN.Q. (E) CRAWL SPACE ACCESS TO REMAIN.demo sheet notes##--DETAIL NUMBERSHEET NUMBEREXTERIOR ELEVATION REFERENCE TAG(N) 2x STUD WALL -EXTERIOR WALL TO RECEIVE 2X6 WITH R-13 BATT. INSULATION SEETITLE 24 FOR MORE INFO.1. NEW RELOCATED WASHER. PROVIDE POWER2. PROVIDE WATER HAMMER ARRESTORS AT ALL APPLIANCES THAT HAVE QUICK-ACTING VALVES (I.E. DISHWASHER HOT WATER LINEAND THE HOT/COLD WATER LINES FOR THE CLOTHES WASHER.) 2022CPC 609.103. PROVIDE NEW DISHWASHER. PROVIDE POWER AND PLUMBING. ON THE DISCHARGE SIDE OF THE DISHWASHER PROVIDE A LISTEDAIR GAP FITTING. LISTED AIR GAPS SHALL BE INSTALLED WITH THE FLOOD LEVEL MARKING AT OR ABOVE THE FLOOD LEVEL OF THESINK OR DRAIN BOARD WHICHEVER IS HIGHER PER CPC SECTION 807.3.4. INSTALLATION OF A DEDICATED FUEL SHUT OFF VALVE SHALL BE WITHIN 6'-0" OF THE GAS APPLIANCE IT SERVES. CPC 230.79.EARTHQUAKE-ACTUATED GAS SHUTOFF VALVES DESIGNED TO AUTOMATICALLY SHUT OFF THE GAS AT THE LOCATION OF THEVALVE IN THE EVENT OF A SEISMIC DISTURBANCE AND CERTIFIED BY THE STATED ARCHITECT AS CONFORMING TO CALIFORNIACODE OF REGULATIONS, TITLE 24, PART 12, CHAPTER 12É16É1, SHALL BE INSTALLED IN ALL NEW BUILDINGS AND IN EXISTINGBUILDINGS THAT UNDERGO ALTERATIONS OR ADDITIONS THAT EXCEED $10,000.5. PROVIDE NEW GAS COOKING RANGE (PROVIDE POWER) WITH NEW EXHAUST HOOD (PROVIDE POWER) WITH A MIN. VENTILATIONEXHAUST RATE OF 100 CFM. HOUSEHOLD COOKING APPLIANCES SHALL HAVE A VERTICAL CLEARANCE ABOVE THE COOKING TOPOF NOT LESS THAN THIRTY - 30" INCHES TO COMBUSTIBLE MATERIAL OR METAL CABINETS, EXCEPT WHERE 24 INCHES IS ALLOWEDPER CODE OR MANUFACTURER'S SPECIFICATION. CMC 920.3.2.6. RANGE HOODS SHALL BE PERMITTED TO BE CORD-AND-PLUG-CONNECTED WITH A FLEXIBLE COURT IDENTIFIED AS SUITABLE FORUSE ON RANGE HOODS IN THE INSTALLATION INSTRUCTIONS OF THE APPLIANCE MANUFACTURER, WHERE ALL THE FOLLOWINGCONDITIONS ARE MET: THE FLEXIBLE CORD IS TERMINATED WITH A GROUNDING-TYPE ATTACHMENT PLUG. THE LENGTH OF THECORD IS 18 INCHES TO 4 FEET. RECEPTACLES ARE LOCATED TO PROTECT AGAINST PHYSICAL DAMAGE TO THE FLEXIBLE CORD.THE RECEPTACLES IS ACCESSIBLE. THE RECEPTACLE IS SUPPLIED BY AN INDIVIDUAL BRANCH CIRCUIT.7. IF OCCURS ELECTRIC STOVES AND OVENS SHALL BE SUPPLIED WITH 40- OR 50-AMP BRANCH CIRCUIT.8. PROVIDE NEW SINK WITH CALGREEN COMPLIANT FAUCET WITH NEW GARBAGE DISPOSAL (PROVIDE POWER).9. NEW REFRIGERATOR/ICE MAKER/WINE COOLER (PROVIDE POWER AND ICE MAKER OUTLET BOX AND CONNECT).10. NEW SOLID COUNTER TOP WITH UPPER AND LOWER CABINETS.11. COUNTERTOP AND WHERE THE COUNTERTOP DOES NOT EXTEND MORE THAN 6 INCHES BEYOND ITS BASE.12. NEW SOLID SURFACE COUNTER KITCHEN ISLAND AND BAR COUNTER WITH BASE CABINET.13. COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER SHALL PROTECT ALL RECEPTACLES IN ALL BEDROOMS, DINING ROOMS,LIVING ROOMS, PARLORS, LIBRARIES, DENS SUNROOMS, RECREATION ROOMS, CLOSETS, KITCHENS. LAUNDRY AREAS. HALLWAYSOR SIMILAR ROOMS OR AREAS WITH BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE-PHASE, 15 AND 20-AMPERE RECEPTACLEOUTLETS, AND BE READILY ACCESSIBLE. 2022 CEC SECTION 210.1214. TWO 20-AMP GFCI PROTECTED CIRCUITS WILL BE PROVIDED IN THE KITCHEN COUNTER AND ISLAND OUTLETS AND SHALL COMPLYWITH ART. 210.52 (C) (5) EXCEPTION TO (5) CEC 202215. LIGHTING INTEGRAL TO EXHAUST FANS SHALL BE CONTROLLED SEPARATELY FROM THE EXHAUST FANS. 150.0 (K) 28. LIGHTINGSHALL HAVE VACANCY SENSOR. EXHAUST FAN SHALL BE 50 CFM MIN.16. PROVIDE WATER CLOSETS TO BE MAX. 1.28 GAL. PER FLUSH.17. SHOWER/TUB W/ FULL HEIGHT TILE WALLS & TEMPERED GLASS ENCLOSURE. USE BITUTHANE 4,000 WATERPROOFING MEMBRANEOVER 1/2" WONDER BOARD & WALLS, CEILING, & FLOOR.18. NEW SOLID SURFACE (NON-SLIP RESISTANT) SHOWER PAN AND WALLS19. PROVIDE SHOWER FINISHED TO 72" ABOVE DRAIN. PROVIDE PRESSURE OR THERMOSTATIC MIXING VALUE @ SHOWER ANDJACUZZI/TUB, WHICH LIMITS WATER TEMPERATURE TO 120°F. SHOWER HEAD SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60PSI.20. NEW SINK AND FAUCET. PROVIDE FAUCET TO BE MAX 1.2 CMP AT 60 PSI.METERING FAUCETS SHALL NOT EXCEED 0.2 GALLONS PERMETERING CYCLE.21. WINDOW MODIFICATIONS: REPLACEMENT AND NEW WINDOWS: SHALL HAVE A U-FACTOR EQUAL TO 0.3022. PROVIDE NEW COMBO UNIT SMOKE DETECTOR AND CARBON MONOXIDE DETECTOR W/BATTERY BACK-UP IN HALLWAY.23. PROVIDE NEW 24" X 48" FLAT PROFILE SKYLIGHT.24. PROVIDE NEW TANKLESS WATER HEATER.25. NEW MIN. 36"x24" ATTIC ACCESS26. NEW PREFABRICATED STAIRS.27. NEW P.T. POSTS ON CONC. BASE 2" ABOVE FINISHED GRADE (TYP.)28. NEW DECKING OVER FRAMING. S.S.D. FOR FRAMING DETAILS.29. NEW AIR CONDITIONER.new sheet notes##KITCHEN GENERAL NOTES (2022 CBC REQUIREMENTS):WATER CONSERVING PLUMBING FIXTURES REQUIREMENTS:• KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE. FLOWMAY TEMPORARILY INCREASE TO 2.2 GALLONS PER MINUTE, BUT MUST DEFAULT TO A MAXIMUM OF 1.8GALLONS PER MINUTE [CGBSC 4.303.1.4.4]• PRIOR TO FINAL INSPECTION ALL NON-COMPLIANT PLUMBING FIXTURES SHALL BE UPGRADEDWITH WATER-CONSERVING FIXTURES AS REQUIRED BY CIVIL CODE 1101.1. A COMPLETED AND SIGNEDCERTIFICATE OF COMPLIANCE SHALL BE PROVIDED TO THE BUILDING INSPECTOR.ELECTRICAL REQUIREMENTS:• RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL COUNTERTOPOR WORK SURFACE IS MORE THAN 24 INCHES FROM A RECEPTACLE IN THAT SPACE. [CEC 210.52(C)(1)]• RECEPTACLE OUTLETS SHALL BE INSTALLED AT EACH KITCHEN COUNTERTOP AND WORKSURFACE THAT IS 12 INCHES OR WIDER. [CEC 210.52(C)(1)]• AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH ISLAND OR PENINSULARCOUNTER SPACE WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12INCHES OR GREATER. [CEC 210-52(C)(2) AND 210.52(C)(3)]• ALL ELECTRICAL OUTLETS SERVING KITCHEN COUNTERTOPS AND DISHWASHERS SHALL BE GFCIPROTECTED. GROUND FAULT CIRCUIT INTERRUPTERS SHALL BE LOCATED IN A READILY ACCESSIBLELOCATION. [CEC 210.8(A)(D)]• AT LEAST TWO SEPARATE 20-AMPERE BRANCH CIRCUITS SHALL BE PROVIDED FOR SMALLKITCHEN APPLIANCES. THESE CIRCUITS ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETSONLY AND CANNOT SERVE DISHWASHER, MICROWAVE, RANGE HOOD, GARBAGE DISPOSAL, ETC.[CEC 210.11(C)(1) AND 210.52(B)(3)]• ALL ADDED/REPLACED RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES ANDSHALL BE ARC FAULT PROTECTED. [CEC 406.12]2022 BATHROOM REMODEL REQUIREMENTS:1. PROVIDE WATERPROOFED MATERIAL AT SHOWER WALLS.2. ALL RECEPTACLES SHALL BE GFCI PROTECTED AND CONNECTED TO A DEDICATED 15 AND 20 AMPS CIRCUIT ÂCEC 210.8Ã3. ALL HARDWIRED LIGHTING SHALL BE HIGH EFFICACY. ÂCA ENERGY EFF. STANDARDS, SECTION 150(K))4. EXHAUST FANS ARE REQUIRED IN ALL BATHROOMS, EVEN IF AN OPERABLE WINDOW IS INSTALLED. CRC 303.3\5. EXHAUST FANS AND LIGHTING SHALL HAVE SEPARATE CONTROL SWITCHES, (EVEN IF A COMBINATION UNIT IS INSTALLED). THEEXHAUST FAN MAY NEED TO BE SUPPLIED BY A GFCI PROTECTED CIRCUIT BASED ON THE MANUFACTURER’FS REQUIREMENTS. CEC150.0 (K)(2B)6. EXHAUST FANS SHALL TERMINATE A MINIMUM OF 3’F FROM PROPERTY LINE AND 3’F FROM OPENINGS INTO A BUILDING. (CMC502.2.1)7. EXHAUST FANS AT SHOWER SHALL BE LISTED FOR WET LOCATION AND SHALL BE GFCI PROTECTED. CEC 210.88. SHOWER ENCLOSURE DOORS SHALL OPEN OUTWARD AND MAINTAIN 22”H CLEARANCE CPC 408.59. SHOWER COMPARTMENT SHALL BE A MINIMUM 1,024 SQUARE INCHES ENCOMPASSING A 30”H CIRCLE. CPC 408.610. WATER CLOSETS (MAXIMUM 1.28 GPMÃ SHALL BE CLEAR 30 INCHES WIDE 15 INCHES ON CENTER) AND 24 INCHES IN FRONT. CPC402.511. SHOWER HEADS (MAXIMUM 1.8 GPM CPC 408.2 & FAUCETS (MAXIMUM 1.2 GPM CPC 407.2)12. BATHTUB/WHIRLPOOLS AND SHOWER VALVES SHALL BE APPROVED PRESSURE-BALANCED OR THERMOSTATIC MIXING TYPEADJUSTED TO A MAXIMUM OF 120 DEGREES. CPC 408.311 (E) OFFICE9' 0 3/4" X 16' 7"8'-6"(E)11'-6"(E)3'-4"(E)SKYLIGHTSKYLIGHT72"x22"h: 0' 5"11'-6"(E)3'-4"(E)SKYLIGHTSKYLIGHT72"x22"h: 0' 5"DN.50"x54"(n) sliding wdwegress4'-10"30"x80"30"x80"30"x80"(N) W.I.C.(N) BATHROOM7'-418"10'-1138"8'-934"4'-8"10'-0"6'-2"6'-918"18'-312"(N) ATTICACCESSW/PULLDOWNLADDERPREFABDUMBWAITER3'-0"(N) ATTICAIR HANDLINGUNIT24"X24"(n) flat profileskylightW1D3D3D3(N) ATTICACCESS(N) SUNROOM BELOWLIVING ROOM BELOW96"x48"(n) fixedw/smart glass 9'-112"5'-434"5'-434"1SCALE: 1/4" = 1'-0"A4.0EXISTING AND DEMO AND NEWPROPOSED THIRD FLOOR PLANS1# description datedate354plan checkclient reviewrevision history2dateconstructionbiddingarchproj projmgrnumprojscaledrawing release statusconsultantconsultantAS NOTEDsheetnumber4.19.2024Ken MacDonald'sResidenceApplicationPD-25-002Remodeling & Addition130 Vasona Oaks Dr,Los Gatos, CA 95032general notes1. This sheet is part of a set and is not to be used alone.2. This sheet is not to be used for construction unless thedesigner's signature appear on drawings and status boxindicates drawings have been released for construction.3. These plans and prints thereof, as instruments ofservice, are owned by the designer and are for use onthis project only. Reproduction and/or distribution withoutthe prior written consent of the designer is forbidden.4. Copyright Slcdesign, 2025xDo not scale or measure plan set.xAll vendors shall measure as builts/current framingconditions prior to casework/cabinet fabricationdisclaimernew proposed third floor planexisting and demo third floor plan2SCALE: 1/4" = 1'-0"NNFNP4A7.02A7.01A7.03A7.08A7.06A7.05A7.07A7.01A8.01617181920212325A4.02NEW PROPOSEDPLAN252A8.0(E) STUD WALL TO REMAINlegend(E) WALL, DOORS AND WINDOWS TO REMOVEA. REMOVE EXISTING DOORS (SHOWN DASHED).B. REMOVE EXISTING DOOR (SHOWN DASHED). INFILL WITH NEW WALL AND MATCH TO ALIGN WITH EXISTINGADJACENT.C. REMOVE EXISTING DOOR (SHOWN DASHED). REPLACE WITH NEW DOOR.D. REMOVE EXITING WINDOW. (SHOWN DASHED).E. REMOVE EXISTING WINDOWS (SHOWN DASHED). REPLACE WITH NEW DOOR.F. REMOVE EXISTING WINDOWS (SHOWN DASHED). FILLED WITH NEW WALL.G. REMOVE THIS PORTION OF EXISTING WALL.H. REMOVE (E) KITCHEN UPPER & LOWER CABINET, COUNTERTOP, FAUCET, STOVE, REFRIGERATOR,DISHWASHER, DISPOSAL, & OVEN, CAP & SALVAGE (E) PLUMBING & GAS LINE FOR NEW APPLIANCES, SEEPROPOSED FLOOR PLAN FOR NEW LOCATION.I. REMOVE PLUMBING FIXTURE AND ACCESSORIES. CAP PLUMBING LINES BEHIND WALLS/UNDER FLOOR.J. REMOVE ATTIC ACCESS (SHOWN DASHED).K. REMOVE WATER HEATER (SHOWN DASHED).L. REMOVE AIR CONDITIONER.M. REMOVE EXISTING POST. SEE S.S.D.N. REMOVE EXISTING STEP.O. REMOVE DECK (SHOWN DASHED).P. (E) SKYLIGHT TO REMAIN.Q. (E) CRAWL SPACE ACCESS TO REMAIN.demo sheet notes##--DETAIL NUMBERSHEET NUMBEREXTERIOR ELEVATION REFERENCE TAG(N) 2x STUD WALL -EXTERIOR WALL TO RECEIVE 2X6 WITH R-13 BATT. INSULATION SEETITLE 24 FOR MORE INFO.1. NEW RELOCATED WASHER. PROVIDE POWER2. PROVIDE WATER HAMMER ARRESTORS AT ALL APPLIANCES THAT HAVE QUICK-ACTING VALVES (I.E. DISHWASHER HOT WATER LINEAND THE HOT/COLD WATER LINES FOR THE CLOTHES WASHER.) 2022CPC 609.103. PROVIDE NEW DISHWASHER. PROVIDE POWER AND PLUMBING. ON THE DISCHARGE SIDE OF THE DISHWASHER PROVIDE A LISTEDAIR GAP FITTING. LISTED AIR GAPS SHALL BE INSTALLED WITH THE FLOOD LEVEL MARKING AT OR ABOVE THE FLOOD LEVEL OF THESINK OR DRAIN BOARD WHICHEVER IS HIGHER PER CPC SECTION 807.3.4. INSTALLATION OF A DEDICATED FUEL SHUT OFF VALVE SHALL BE WITHIN 6'-0" OF THE GAS APPLIANCE IT SERVES. CPC 230.79.EARTHQUAKE-ACTUATED GAS SHUTOFF VALVES DESIGNED TO AUTOMATICALLY SHUT OFF THE GAS AT THE LOCATION OF THEVALVE IN THE EVENT OF A SEISMIC DISTURBANCE AND CERTIFIED BY THE STATED ARCHITECT AS CONFORMING TO CALIFORNIACODE OF REGULATIONS, TITLE 24, PART 12, CHAPTER 12É16É1, SHALL BE INSTALLED IN ALL NEW BUILDINGS AND IN EXISTINGBUILDINGS THAT UNDERGO ALTERATIONS OR ADDITIONS THAT EXCEED $10,000.5. PROVIDE NEW GAS COOKING RANGE (PROVIDE POWER) WITH NEW EXHAUST HOOD (PROVIDE POWER) WITH A MIN. VENTILATIONEXHAUST RATE OF 100 CFM. HOUSEHOLD COOKING APPLIANCES SHALL HAVE A VERTICAL CLEARANCE ABOVE THE COOKING TOPOF NOT LESS THAN THIRTY - 30" INCHES TO COMBUSTIBLE MATERIAL OR METAL CABINETS, EXCEPT WHERE 24 INCHES IS ALLOWEDPER CODE OR MANUFACTURER'S SPECIFICATION. CMC 920.3.2.6. RANGE HOODS SHALL BE PERMITTED TO BE CORD-AND-PLUG-CONNECTED WITH A FLEXIBLE COURT IDENTIFIED AS SUITABLE FORUSE ON RANGE HOODS IN THE INSTALLATION INSTRUCTIONS OF THE APPLIANCE MANUFACTURER, WHERE ALL THE FOLLOWINGCONDITIONS ARE MET: THE FLEXIBLE CORD IS TERMINATED WITH A GROUNDING-TYPE ATTACHMENT PLUG. THE LENGTH OF THECORD IS 18 INCHES TO 4 FEET. RECEPTACLES ARE LOCATED TO PROTECT AGAINST PHYSICAL DAMAGE TO THE FLEXIBLE CORD.THE RECEPTACLES IS ACCESSIBLE. THE RECEPTACLE IS SUPPLIED BY AN INDIVIDUAL BRANCH CIRCUIT.7. IF OCCURS ELECTRIC STOVES AND OVENS SHALL BE SUPPLIED WITH 40- OR 50-AMP BRANCH CIRCUIT.8. PROVIDE NEW SINK WITH CALGREEN COMPLIANT FAUCET WITH NEW GARBAGE DISPOSAL (PROVIDE POWER).9. NEW REFRIGERATOR/ICE MAKER/WINE COOLER (PROVIDE POWER AND ICE MAKER OUTLET BOX AND CONNECT).10. NEW SOLID COUNTER TOP WITH UPPER AND LOWER CABINETS.11. COUNTERTOP AND WHERE THE COUNTERTOP DOES NOT EXTEND MORE THAN 6 INCHES BEYOND ITS BASE.12. NEW SOLID SURFACE COUNTER KITCHEN ISLAND AND BAR COUNTER WITH BASE CABINET.13. COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER SHALL PROTECT ALL RECEPTACLES IN ALL BEDROOMS, DINING ROOMS,LIVING ROOMS, PARLORS, LIBRARIES, DENS SUNROOMS, RECREATION ROOMS, CLOSETS, KITCHENS. LAUNDRY AREAS. HALLWAYSOR SIMILAR ROOMS OR AREAS WITH BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE-PHASE, 15 AND 20-AMPERE RECEPTACLEOUTLETS, AND BE READILY ACCESSIBLE. 2022 CEC SECTION 210.1214. TWO 20-AMP GFCI PROTECTED CIRCUITS WILL BE PROVIDED IN THE KITCHEN COUNTER AND ISLAND OUTLETS AND SHALL COMPLYWITH ART. 210.52 (C) (5) EXCEPTION TO (5) CEC 202215. LIGHTING INTEGRAL TO EXHAUST FANS SHALL BE CONTROLLED SEPARATELY FROM THE EXHAUST FANS. 150.0 (K) 28. LIGHTINGSHALL HAVE VACANCY SENSOR. EXHAUST FAN SHALL BE 50 CFM MIN.16. PROVIDE WATER CLOSETS TO BE MAX. 1.28 GAL. PER FLUSH.17. SHOWER/TUB W/ FULL HEIGHT TILE WALLS & TEMPERED GLASS ENCLOSURE. USE BITUTHANE 4,000 WATERPROOFING MEMBRANEOVER 1/2" WONDER BOARD & WALLS, CEILING, & FLOOR.18. NEW SOLID SURFACE (NON-SLIP RESISTANT) SHOWER PAN AND WALLS19. PROVIDE SHOWER FINISHED TO 72" ABOVE DRAIN. PROVIDE PRESSURE OR THERMOSTATIC MIXING VALUE @ SHOWER ANDJACUZZI/TUB, WHICH LIMITS WATER TEMPERATURE TO 120°F. SHOWER HEAD SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60PSI.20. NEW SINK AND FAUCET. PROVIDE FAUCET TO BE MAX 1.2 CMP AT 60 PSI.METERING FAUCETS SHALL NOT EXCEED 0.2 GALLONS PERMETERING CYCLE.21. WINDOW MODIFICATIONS: REPLACEMENT AND NEW WINDOWS: SHALL HAVE A U-FACTOR EQUAL TO 0.3022. PROVIDE NEW COMBO UNIT SMOKE DETECTOR AND CARBON MONOXIDE DETECTOR W/BATTERY BACK-UP IN HALLWAY.23. PROVIDE NEW 24" X 48" FLAT PROFILE SKYLIGHT.24. PROVIDE NEW TANKLESS WATER HEATER.25. NEW MIN. 36"x24" ATTIC ACCESS26. NEW PREFABRICATED STAIRS.27. NEW P.T. POSTS ON CONC. BASE 2" ABOVE FINISHED GRADE (TYP.)28. NEW DECKING OVER FRAMING. S.S.D. FOR FRAMING DETAILS.29. NEW AIR CONDITIONER.new sheet notes##KITCHEN GENERAL NOTES (2022 CBC REQUIREMENTS):WATER CONSERVING PLUMBING FIXTURES REQUIREMENTS:• KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE. FLOWMAY TEMPORARILY INCREASE TO 2.2 GALLONS PER MINUTE, BUT MUST DEFAULT TO A MAXIMUM OF 1.8GALLONS PER MINUTE [CGBSC 4.303.1.4.4]• PRIOR TO FINAL INSPECTION ALL NON-COMPLIANT PLUMBING FIXTURES SHALL BE UPGRADEDWITH WATER-CONSERVING FIXTURES AS REQUIRED BY CIVIL CODE 1101.1. A COMPLETED AND SIGNEDCERTIFICATE OF COMPLIANCE SHALL BE PROVIDED TO THE BUILDING INSPECTOR.ELECTRICAL REQUIREMENTS:• RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL COUNTERTOPOR WORK SURFACE IS MORE THAN 24 INCHES FROM A RECEPTACLE IN THAT SPACE. [CEC 210.52(C)(1)]• RECEPTACLE OUTLETS SHALL BE INSTALLED AT EACH KITCHEN COUNTERTOP AND WORKSURFACE THAT IS 12 INCHES OR WIDER. [CEC 210.52(C)(1)]• AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH ISLAND OR PENINSULARCOUNTER SPACE WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12INCHES OR GREATER. [CEC 210-52(C)(2) AND 210.52(C)(3)]• ALL ELECTRICAL OUTLETS SERVING KITCHEN COUNTERTOPS AND DISHWASHERS SHALL BE GFCIPROTECTED. GROUND FAULT CIRCUIT INTERRUPTERS SHALL BE LOCATED IN A READILY ACCESSIBLELOCATION. [CEC 210.8(A)(D)]• AT LEAST TWO SEPARATE 20-AMPERE BRANCH CIRCUITS SHALL BE PROVIDED FOR SMALLKITCHEN APPLIANCES. THESE CIRCUITS ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETSONLY AND CANNOT SERVE DISHWASHER, MICROWAVE, RANGE HOOD, GARBAGE DISPOSAL, ETC.[CEC 210.11(C)(1) AND 210.52(B)(3)]• ALL ADDED/REPLACED RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES ANDSHALL BE ARC FAULT PROTECTED. [CEC 406.12]2022 BATHROOM REMODEL REQUIREMENTS:1. PROVIDE WATERPROOFED MATERIAL AT SHOWER WALLS.2. ALL RECEPTACLES SHALL BE GFCI PROTECTED AND CONNECTED TO A DEDICATED 15 AND 20 AMPS CIRCUIT ÂCEC 210.8Ã3. ALL HARDWIRED LIGHTING SHALL BE HIGH EFFICACY. ÂCA ENERGY EFF. STANDARDS, SECTION 150(K))4. EXHAUST FANS ARE REQUIRED IN ALL BATHROOMS, EVEN IF AN OPERABLE WINDOW IS INSTALLED. CRC 303.3\5. EXHAUST FANS AND LIGHTING SHALL HAVE SEPARATE CONTROL SWITCHES, (EVEN IF A COMBINATION UNIT IS INSTALLED). THEEXHAUST FAN MAY NEED TO BE SUPPLIED BY A GFCI PROTECTED CIRCUIT BASED ON THE MANUFACTURER’FS REQUIREMENTS. CEC150.0 (K)(2B)6. EXHAUST FANS SHALL TERMINATE A MINIMUM OF 3’F FROM PROPERTY LINE AND 3’F FROM OPENINGS INTO A BUILDING. (CMC502.2.1)7. EXHAUST FANS AT SHOWER SHALL BE LISTED FOR WET LOCATION AND SHALL BE GFCI PROTECTED. CEC 210.88. SHOWER ENCLOSURE DOORS SHALL OPEN OUTWARD AND MAINTAIN 22”H CLEARANCE CPC 408.59. SHOWER COMPARTMENT SHALL BE A MINIMUM 1,024 SQUARE INCHES ENCOMPASSING A 30”H CIRCLE. CPC 408.610. WATER CLOSETS (MAXIMUM 1.28 GPMÃ SHALL BE CLEAR 30 INCHES WIDE 15 INCHES ON CENTER) AND 24 INCHES IN FRONT. CPC402.511. SHOWER HEADS (MAXIMUM 1.8 GPM CPC 408.2 & FAUCETS (MAXIMUM 1.2 GPM CPC 407.2)12. BATHTUB/WHIRLPOOLS AND SHOWER VALVES SHALL BE APPROVED PRESSURE-BALANCED OR THERMOSTATIC MIXING TYPEADJUSTED TO A MAXIMUM OF 120 DEGREES. CPC 408.3WINDOW MODIFICATIONS: REPLACEMENT AND NEW WINDOWS:1. SHALL HAVE A U-FACTOR EQUAL TO 0.30 OR LOWER. EXCEPTIONS:REPLACEMENT SKYLIGHTS, OR NEW SKYLIGHTS UP TO 16 SQUARE FEET, MAY HAVE A U-FACTOR OF 0.55. WHEN 75 SQUARE FEET OR LESS OF FENESTRATION IS REPLACED WINDOWS MAY HAVE A U-FACTOR OF 0.40. [CENC 150.2(B) TABLE 150.1-A]2. FOR WINDOW MODIFICATIONS IN THE HILLSIDE FIRES ZONES 2 AND 3 REFER TO WINDOW ANDDOOR CODE COMPLIANCE CHECKLISTVENTILATION REQUIREMENTS:• TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS SHALL BE AT LEAST 3 FEET FROM PROPERTYLINE AND FROM OPENINGS INTO THE BUILDING, AND 10 FEET FROM A FORCED AIR INLET.[CMC 502.2.1]• WHOLE-BUILDING VENTILATION: KITCHENS REQUIRE VENTILATION AIR FLOW AT 100 CUBIC FEETPER MINUTE OR MORE FOR INTERMEDIATE SYSTEMS OR 5 AIR CHANGES PER HOUR FOR CONTINUOUS SYSTEMS. [ASHRAE 62.2]BUILDING ENVELOPE MODIFICATIONS:EXTERIOR WALL, FLOOR AND ROOF FRAMING SPACES OPENED UP DURING THE COURSE OF REMODELSHALL BE INSULATED. R-13 (2X4 WALL), R-20 (2X6 WALL), R-19 (FLOOR), AND R-19 (ATTIC/ROOF)INSULATION. [CENC 150.0(A)(C)(D)]LIGHTING REQUIREMENTS:• ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY. [CENC 150.0 TABLE 150.0-A]• UNDER CABINET LIGHTING SHALL BE CONTROLLED SEPARATELY FROM CEILING INSTALLEDLIGHTING SUCH THAT ONE CAN BE TURNED ON WITHOUT THE OTHER. [CENC 150.0(2)(K)]• LUMINARIES RECESSED INTO INSULATED CEILINGS:(A) SHALL BE LISTED FOR ZERO CLEARANCE INSULATION COVER (IC RATED);(B) SHALL INCLUDE A LABEL CERTIFYING AIR TIGHT (AT) WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS;(C) SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINARY HOUSING AND CEILING;(D) IF RECESSED LIGHTS ARE EQUIPPED WITH BALLASTS, SHALL ALLOW BALLAST MAINTENANCE ANDREPLACEMENT WITHOUT REQUIRING CUTTING OF HOLES IN THE CEILING; AND(E) SHALL NOT CONTAIN SCREW BASE SOCKETS. [CEES SEC.150(K)12].SMOKE ALARMS: DWELLINGS ARE TO BE EQUIPPED WITH SMOKE ALARMS INSTALLED IN THE FOLLOWING LOCATIONS: [CRC 314.4]• IN EACH EXISTING SLEEPING ROOM.• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.• ON EACH STORY INCLUDING BASEMENTS AND HABITABLE ATTICS, NOT INCLUDING CRAWLSPACES AND UNINHABITABLE ATTICS.• INSTALLED NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS WOULDPREVENT PLACEMENT OF A SMOKE ALARM REQUIRED BY CRC R314.3(4).CARBON MONOXIDE ALARMS: DWELLINGS THAT HAVE ATTACHED GARAGES WITH AN OPENING THAT COMMUNICATES WITH THE DWELLING UNIT, OR FUEL BURNINGAPPLIANCES, OR FIRE PLACE ARE TO BE EQUIPPED WITH CARBON MONOXIDE ALARMS INSTALLED INTHE FOLLOWING LOCATIONS: [CRC 315.3]• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.• ON EVERY OCCUPIABLE LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS.• WHERE A FUEL-BURNING APPLIANCE IS LOCATED WITHIN A BEDROOM OR ITS ATTACHED BATHROOM. A CARBON MONOXIDE ALARM SHALL BE INSTALLED WITHIN THEBEDROOM.ALARM INTERCONNECTION AND POWER: SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INTERCONNECTED SUCH THAT ACTIVATION OF ONE ALARM WILLACTIVATE ALL OF THE ALARMS AND SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING. EXCEPTION: WHERE REPAIRS OR ALTERATIONS TO EXISTINGBUILDINGS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHES AND THERE IS NO ACCESS BY MEANS OF ATTIC, BASEMENT OR CRAWL SPACE. [CRC 314.4 AND§314.6]SMOKE AND CARBON MONOXIDE DETECTORWHEN ALTERATIONS,REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, THE INDIVIDUAL DWELLINGUNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. [R314.2.2]11 (E) BEDROOM34"x58"h: 1' 10"46"x40"h: 3' 4"70"x40"h: 3' 4"SKYLIGHT8'-6"(E)11'-6"(E)UPDN.UP9'-0"(N) CLG(N) W.I.C.9'-0"(N) CLG30"x80"FRIDGEPANTRYwetbar areawinefridgeSKYLIGHTSKYLIGHTPREFABDUMBWAITER30"x80"makeup30"x80"30"x80"D / WNEW EXTENDED DECK UP TO 5 FEETFROM PROPERTY LINE WILL NEED TOHAVE HEAVY TIMBER (1 HOUR FIRERATING)SO IT IS BETTER TO REPLACE THEENTIRE DECK WITH THE SAMEMATERIAL.(N) ATTICACCESSW/PULLDOWNLADDERADDITIONEXISTING(N) SUNROOMD1D1D3D3D3D3(N) BATHROOM(N) BATHROOM192"x80"(N) FOLDING DOORSTEMPERED-5 EQ. PANELS192"x80"(N) FOLDING DOORSTEMPERED EQ. PANELS30"x80"D3ELECTRICPANEL(E) BEDROOM8'-0"(E)(E) BEDROOM13' 9 1/8" X 11' 1 5/8"8'-0"(E)(E) GARAGE20' 1 3/4" X 21' 3 1/4"8'-10"(E)(E) ENTRY6' 11 1/2" X 4' 10"8'-0"(E)94"x36"h: 3' 4"68"x20"h: 4' 6"30"x80"28"x80"84"x80"28"x80"36"x80"192"x82"70"x80"58"x80"28"x80"32"x80"36"x80"14"x30"h: 4' 4"GAS METERELECTRIC METERCRAWLSPACEACCESS32"x80"72"x80"RECONFLAUNDRYRM.PREFABDUMBWAITER(N)TANKLESSW.H.WINE CELLAR @ FINISHED CRAWLSPACE BELOW GARAGE FLOOR(N)ACD4D230"x80"D3 (N)WATERSOFTENER(N) COVERED PATIORECONFBATHROOM1SCALE: 1/4" = 1'-0"2SCALE: 1/4" = 1'-0"A5.0NEW PROPOSED FIRST ANDSECOND FLOOR PLANS1# description datedate354plan checkclient reviewrevision history2dateconstructionbiddingarchproj projmgrnumprojscaledrawing release statusconsultantconsultantAS NOTEDsheetnumber4.19.2024Ken MacDonald'sResidenceApplicationPD-25-002Remodeling & Addition130 Vasona Oaks Dr,Los Gatos, CA 95032general notes1. This sheet is part of a set and is not to be used alone.2. This sheet is not to be used for construction unless thedesigner's signature appear on drawings and status boxindicates drawings have been released for construction.3. These plans and prints thereof, as instruments ofservice, are owned by the designer and are for use onthis project only. Reproduction and/or distribution withoutthe prior written consent of the designer is forbidden.4. Copyright Slcdesign, 2025xDo not scale or measure plan set.xAll vendors shall measure as builts/current framingconditions prior to casework/cabinet fabricationdisclaimernew proposed first floor plan new proposed second floor planNN8A7.06A7.05A7.07A7.08A7.06A7.05A7.07A7.01A8.015TYP.1A8.0S240vG.F.ISVS3WPSSvS SG.F.IG.F.ISSSvSG.F.IS240vG.F.IundercounterG.F.IG.F.IG.F.IG.F.IG.F.IG.F.IG.F.IG.F.IG.F.IG.F.ISSSKITCHEN GENERAL NOTES (2022 CBC REQUIREMENTS):WATER CONSERVING PLUMBING FIXTURES REQUIREMENTS:• KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE. FLOWMAY TEMPORARILY INCREASE TO 2.2 GALLONS PER MINUTE, BUT MUST DEFAULT TO A MAXIMUM OF 1.8GALLONS PER MINUTE [CGBSC 4.303.1.4.4]• PRIOR TO FINAL INSPECTION ALL NON-COMPLIANT PLUMBING FIXTURES SHALL BE UPGRADEDWITH WATER-CONSERVING FIXTURES AS REQUIRED BY CIVIL CODE 1101.1. A COMPLETED AND SIGNEDCERTIFICATE OF COMPLIANCE SHALL BE PROVIDED TO THE BUILDING INSPECTOR.ELECTRICAL REQUIREMENTS:• RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL COUNTERTOPOR WORK SURFACE IS MORE THAN 24 INCHES FROM A RECEPTACLE IN THAT SPACE. [CEC 210.52(C)(1)]• RECEPTACLE OUTLETS SHALL BE INSTALLED AT EACH KITCHEN COUNTERTOP AND WORKSURFACE THAT IS 12 INCHES OR WIDER. [CEC 210.52(C)(1)]• AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH ISLAND OR PENINSULARCOUNTER SPACE WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12INCHES OR GREATER. [CEC 210-52(C)(2) AND 210.52(C)(3)]• ALL ELECTRICAL OUTLETS SERVING KITCHEN COUNTERTOPS AND DISHWASHERS SHALL BE GFCIPROTECTED. GROUND FAULT CIRCUIT INTERRUPTERS SHALL BE LOCATED IN A READILY ACCESSIBLELOCATION. [CEC 210.8(A)(D)]• AT LEAST TWO SEPARATE 20-AMPERE BRANCH CIRCUITS SHALL BE PROVIDED FOR SMALLKITCHEN APPLIANCES. THESE CIRCUITS ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETSONLY AND CANNOT SERVE DISHWASHER, MICROWAVE, RANGE HOOD, GARBAGE DISPOSAL, ETC.[CEC 210.11(C)(1) AND 210.52(B)(3)]• ALL ADDED/REPLACED RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES ANDSHALL BE ARC FAULT PROTECTED. [CEC 406.12]WINDOW MODIFICATIONS: REPLACEMENT AND NEW WINDOWS:1. SHALL HAVE A U-FACTOR EQUAL TO 0.30 OR LOWER. EXCEPTIONS:REPLACEMENT SKYLIGHTS, OR NEW SKYLIGHTS UP TO 16 SQUARE FEET, MAY HAVE A U-FACTOR OF 0.55. WHEN 75 SQUARE FEET OR LESS OF FENESTRATION IS REPLACED WINDOWS MAY HAVE A U-FACTOR OF 0.40. [CENC 150.2(B) TABLE 150.1-A]2. FOR WINDOW MODIFICATIONS IN THE HILLSIDE FIRES ZONES 2 AND 3 REFER TO WINDOW ANDDOOR CODE COMPLIANCE CHECKLISTVENTILATION REQUIREMENTS:• TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS SHALL BE AT LEAST 3 FEET FROM PROPERTYLINE AND FROM OPENINGS INTO THE BUILDING, AND 10 FEET FROM A FORCED AIR INLET.[CMC 502.2.1]• WHOLE-BUILDING VENTILATION: KITCHENS REQUIRE VENTILATION AIR FLOW AT 100 CUBIC FEETPER MINUTE OR MORE FOR INTERMEDIATE SYSTEMS OR 5 AIR CHANGES PER HOUR FOR CONTINUOUS SYSTEMS. [ASHRAE 62.2]2022 BATHROOM REMODEL REQUIREMENTS:1. PROVIDE WATERPROOFED MATERIAL AT SHOWER WALLS.2. ALL RECEPTACLES SHALL BE GFCI PROTECTED AND CONNECTED TO A DEDICATED 15 AND 20 AMPS CIRCUIT ÂCEC 210.8Ã3. ALL HARDWIRED LIGHTING SHALL BE HIGH EFFICACY. ÂCA ENERGY EFF. STANDARDS, SECTION 150(K))4. EXHAUST FANS ARE REQUIRED IN ALL BATHROOMS, EVEN IF AN OPERABLE WINDOW IS INSTALLED. CRC 303.3\5. EXHAUST FANS AND LIGHTING SHALL HAVE SEPARATE CONTROL SWITCHES, (EVEN IF A COMBINATION UNIT IS INSTALLED). THEEXHAUST FAN MAY NEED TO BE SUPPLIED BY A GFCI PROTECTED CIRCUIT BASED ON THE MANUFACTURER’FS REQUIREMENTS. CEC150.0 (K)(2B)6. EXHAUST FANS SHALL TERMINATE A MINIMUM OF 3’F FROM PROPERTY LINE AND 3’F FROM OPENINGS INTO A BUILDING. (CMC502.2.1)7. EXHAUST FANS AT SHOWER SHALL BE LISTED FOR WET LOCATION AND SHALL BE GFCI PROTECTED. CEC 210.88. SHOWER ENCLOSURE DOORS SHALL OPEN OUTWARD AND MAINTAIN 22”H CLEARANCE CPC 408.59. SHOWER COMPARTMENT SHALL BE A MINIMUM 1,024 SQUARE INCHES ENCOMPASSING A 30”H CIRCLE. CPC 408.610. WATER CLOSETS (MAXIMUM 1.28 GPMÃ SHALL BE CLEAR 30 INCHES WIDE 15 INCHES ON CENTER) AND 24 INCHES IN FRONT. CPC402.511. SHOWER HEADS (MAXIMUM 1.8 GPM CPC 408.2 & FAUCETS (MAXIMUM 1.2 GPM CPC 407.2)12. BATHTUB/WHIRLPOOLS AND SHOWER VALVES SHALL BE APPROVED PRESSURE-BALANCED OR THERMOSTATIC MIXING TYPEADJUSTED TO A MAXIMUM OF 120 DEGREES. CPC 408.3BUILDING ENVELOPE MODIFICATIONS:EXTERIOR WALL, FLOOR AND ROOF FRAMING SPACES OPENED UP DURING THE COURSE OF REMODELSHALL BE INSULATED. R-13 (2X4 WALL), R-20 (2X6 WALL), R-19 (FLOOR), AND R-19 (ATTIC/ROOF)INSULATION. [CENC 150.0(A)(C)(D)]LIGHTING REQUIREMENTS:• ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY. [CENC 150.0 TABLE 150.0-A]• UNDER CABINET LIGHTING SHALL BE CONTROLLED SEPARATELY FROM CEILING INSTALLEDLIGHTING SUCH THAT ONE CAN BE TURNED ON WITHOUT THE OTHER. [CENC 150.0(2)(K)]• LUMINARIES RECESSED INTO INSULATED CEILINGS:(A) SHALL BE LISTED FOR ZERO CLEARANCE INSULATION COVER (IC RATED);(B) SHALL INCLUDE A LABEL CERTIFYING AIR TIGHT (AT) WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS;(C) SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINARY HOUSING AND CEILING;(D) IF RECESSED LIGHTS ARE EQUIPPED WITH BALLASTS, SHALL ALLOW BALLAST MAINTENANCE ANDREPLACEMENT WITHOUT REQUIRING CUTTING OF HOLES IN THE CEILING; AND(E) SHALL NOT CONTAIN SCREW BASE SOCKETS. [CEES SEC.150(K)12].SMOKE ALARMS: DWELLINGS ARE TO BE EQUIPPED WITH SMOKE ALARMS INSTALLED IN THE FOLLOWING LOCATIONS: [CRC 314.4]• IN EACH EXISTING SLEEPING ROOM.• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.• ON EACH STORY INCLUDING BASEMENTS AND HABITABLE ATTICS, NOT INCLUDING CRAWLSPACES AND UNINHABITABLE ATTICS.• INSTALLED NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS WOULDPREVENT PLACEMENT OF A SMOKE ALARM REQUIRED BY CRC R314.3(4).CARBON MONOXIDE ALARMS: DWELLINGS THAT HAVE ATTACHED GARAGES WITH AN OPENING THAT COMMUNICATES WITH THE DWELLING UNIT, OR FUEL BURNINGAPPLIANCES, OR FIRE PLACE ARE TO BE EQUIPPED WITH CARBON MONOXIDE ALARMS INSTALLED INTHE FOLLOWING LOCATIONS: [CRC 315.3]• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.• ON EVERY OCCUPIABLE LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS.• WHERE A FUEL-BURNING APPLIANCE IS LOCATED WITHIN A BEDROOM OR ITS ATTACHED BATHROOM. A CARBON MONOXIDE ALARM SHALL BE INSTALLED WITHIN THEBEDROOM.ALARM INTERCONNECTION AND POWER: SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INTERCONNECTED SUCH THAT ACTIVATION OF ONE ALARM WILLACTIVATE ALL OF THE ALARMS AND SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING. EXCEPTION: WHERE REPAIRS OR ALTERATIONS TO EXISTINGBUILDINGS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHES AND THERE IS NO ACCESS BY MEANS OF ATTIC, BASEMENT OR CRAWL SPACE. [CRC 314.4 AND§314.6]SMOKE AND CARBON MONOXIDE DETECTORWHEN ALTERATIONS,REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, THE INDIVIDUAL DWELLINGUNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. [R314.2.2]electrical legendSSWITCH @ 48" U.F.F.(E) SMOKE AND CARBON MONOXIDE DETECTOR4" LED RECESSED LIGHT FIXTURE BATHROOM/EXHAUST FAN DUPLEX OUTLET @ 12" A.F.F. / 32"-36" A.F.F. AT COUNTER. G.F.I. OUTLET @ 32" - 36" A.F.F.G.F.IW/ LED LIGHT AND MOISTURE CONTROLVACANCY SENSOR SWITCH @ 48" A.F.F.SvGAS STUBLED WALL HUNG LIGHT FIXTURE BATHROOMLED RECESSED LIGHT FIXTURE WITH WATER PROOF LENSLED PENDANT LIGHT FIXTURE KITCHEN240V G.F.I. OUTLET @ 32" - 36" A.F.F.240V(E) STUD WALL TO REMAINlegend--DETAIL NUMBERSHEET NUMBEREXTERIOR ELEVATION REFERENCE TAG(N) 2x STUD WALL -EXTERIOR WALL TO RECEIVE 2X6 WITH R-13 BATT. INSULATION SEETITLE 24 FOR MORE INFO.new sheet notes2A8.02A8.0G.F.IG.F.ISSv S4S4S41. NEW RELOCATED WASHER. PROVIDE POWER2. PROVIDE WATER HAMMER ARRESTORS AT ALL APPLIANCES THAT HAVE QUICK-ACTING VALVES (I.E. DISHWASHER HOT WATER LINEAND THE HOT/COLD WATER LINES FOR THE CLOTHES WASHER.) 2022CPC 609.103. PROVIDE NEW DISHWASHER. PROVIDE POWER AND PLUMBING. ON THE DISCHARGE SIDE OF THE DISHWASHER PROVIDE A LISTEDAIR GAP FITTING. LISTED AIR GAPS SHALL BE INSTALLED WITH THE FLOOD LEVEL MARKING AT OR ABOVE THE FLOOD LEVEL OF THESINK OR DRAIN BOARD WHICHEVER IS HIGHER PER CPC SECTION 807.3.4. INSTALLATION OF A DEDICATED FUEL SHUT OFF VALVE SHALL BE WITHIN 6'-0" OF THE GAS APPLIANCE IT SERVES. CPC 230.79.EARTHQUAKE-ACTUATED GAS SHUTOFF VALVES DESIGNED TO AUTOMATICALLY SHUT OFF THE GAS AT THE LOCATION OF THEVALVE IN THE EVENT OF A SEISMIC DISTURBANCE AND CERTIFIED BY THE STATED ARCHITECT AS CONFORMING TO CALIFORNIACODE OF REGULATIONS, TITLE 24, PART 12, CHAPTER 12É16É1, SHALL BE INSTALLED IN ALL NEW BUILDINGS AND IN EXISTINGBUILDINGS THAT UNDERGO ALTERATIONS OR ADDITIONS THAT EXCEED $10,000.5. PROVIDE NEW GAS COOKING RANGE (PROVIDE POWER) WITH NEW EXHAUST HOOD (PROVIDE POWER) WITH A MIN. VENTILATIONEXHAUST RATE OF 100 CFM. HOUSEHOLD COOKING APPLIANCES SHALL HAVE A VERTICAL CLEARANCE ABOVE THE COOKING TOPOF NOT LESS THAN THIRTY - 30" INCHES TO COMBUSTIBLE MATERIAL OR METAL CABINETS, EXCEPT WHERE 24 INCHES IS ALLOWEDPER CODE OR MANUFACTURER'S SPECIFICATION. CMC 920.3.2.6. RANGE HOODS SHALL BE PERMITTED TO BE CORD-AND-PLUG-CONNECTED WITH A FLEXIBLE COURT IDENTIFIED AS SUITABLE FORUSE ON RANGE HOODS IN THE INSTALLATION INSTRUCTIONS OF THE APPLIANCE MANUFACTURER, WHERE ALL THE FOLLOWINGCONDITIONS ARE MET: THE FLEXIBLE CORD IS TERMINATED WITH A GROUNDING-TYPE ATTACHMENT PLUG. THE LENGTH OF THECORD IS 18 INCHES TO 4 FEET. RECEPTACLES ARE LOCATED TO PROTECT AGAINST PHYSICAL DAMAGE TO THE FLEXIBLE CORD.THE RECEPTACLES IS ACCESSIBLE. THE RECEPTACLE IS SUPPLIED BY AN INDIVIDUAL BRANCH CIRCUIT.7. IF OCCURS ELECTRIC STOVES AND OVENS SHALL BE SUPPLIED WITH 40- OR 50-AMP BRANCH CIRCUIT.8. PROVIDE NEW SINK WITH CALGREEN COMPLIANT FAUCET WITH NEW GARBAGE DISPOSAL (PROVIDE POWER).9. NEW REFRIGERATOR/ICE MAKER/WINE COOLER (PROVIDE POWER AND ICE MAKER OUTLET BOX AND CONNECT).10. NEW SOLID COUNTER TOP WITH UPPER AND LOWER CABINETS.11. COUNTERTOP AND WHERE THE COUNTERTOP DOES NOT EXTEND MORE THAN 6 INCHES BEYOND ITS BASE.12. NEW SOLID SURFACE COUNTER KITCHEN ISLAND AND BAR COUNTER WITH BASE CABINET.13. COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER SHALL PROTECT ALL RECEPTACLES IN ALL BEDROOMS, DINING ROOMS,LIVING ROOMS, PARLORS, LIBRARIES, DENS SUNROOMS, RECREATION ROOMS, CLOSETS, KITCHENS. LAUNDRY AREAS. HALLWAYSOR SIMILAR ROOMS OR AREAS WITH BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE-PHASE, 15 AND 20-AMPERE RECEPTACLEOUTLETS, AND BE READILY ACCESSIBLE. 2022 CEC SECTION 210.1214. TWO 20-AMP GFCI PROTECTED CIRCUITS WILL BE PROVIDED IN THE KITCHEN COUNTER AND ISLAND OUTLETS AND SHALL COMPLYWITH ART. 210.52 (C) (5) EXCEPTION TO (5) CEC 202215. LIGHTING INTEGRAL TO EXHAUST FANS SHALL BE CONTROLLED SEPARATELY FROM THE EXHAUST FANS. 150.0 (K) 28. LIGHTINGSHALL HAVE VACANCY SENSOR. EXHAUST FAN SHALL BE 50 CFM MIN.16. PROVIDE WATER CLOSETS TO BE MAX. 1.28 GAL. PER FLUSH.17. SHOWER/TUB W/ FULL HEIGHT TILE WALLS & TEMPERED GLASS ENCLOSURE. USE BITUTHANE 4,000 WATERPROOFING MEMBRANEOVER 1/2" WONDER BOARD & WALLS, CEILING, & FLOOR.18. NEW SOLID SURFACE (NON-SLIP RESISTANT) SHOWER PAN AND WALLS19. PROVIDE SHOWER FINISHED TO 72" ABOVE DRAIN. PROVIDE PRESSURE OR THERMOSTATIC MIXING VALUE @ SHOWER ANDJACUZZI/TUB, WHICH LIMITS WATER TEMPERATURE TO 120°F. SHOWER HEAD SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60PSI.20. NEW SINK AND FAUCET. PROVIDE FAUCET TO BE MAX 1.2 CMP AT 60 PSI.METERING FAUCETS SHALL NOT EXCEED 0.2 GALLONS PERMETERING CYCLE.21. WINDOW MODIFICATIONS: REPLACEMENT AND NEW WINDOWS: SHALL HAVE A U-FACTOR EQUAL TO 0.3022. PROVIDE NEW COMBO UNIT SMOKE DETECTOR AND CARBON MONOXIDE DETECTOR W/BATTERY BACK-UP IN HALLWAY.23. PROVIDE NEW 24" X 48" FLAT PROFILE SKYLIGHT.24. PROVIDE NEW TANKLESS WATER HEATER.25. NEW MIN. 36"x24" ATTIC ACCESS26. NEW PREFABRICATED STAIRS.27. NEW P.T. POSTS ON CONC. BASE 2" ABOVE FINISHED GRADE (TYP.)28. NEW DECKING OVER FRAMING. S.S.D. FOR FRAMING DETAILS.29. NEW AIR CONDITIONER.11 11'-6"(E)3'-4"(E)SKYLIGHTSKYLIGHT72"x22"h: 0' 5"DN.50"x54"(n) sliding wdwegress30"x80"30"x80"30"x80"(N) W.I.C.(N) BATHROOM(N) ATTICACCESSW/PULLDOWNLADDERPREFABDUMBWAITER(N) ATTICAIR HANDLINGUNIT24"X24"(n) flat profileskylightW1D3D3D3(N) ATTICACCESS(N) SUNROOM BELOWLIVING ROOM BELOW96"x48"(n) fixedw/smart glass 1SCALE: 1/4" = 1'-0"new proposed third floor planN8A7.06A7.05A7.07A7.01A8.022TYP.15TYP.SSvSS SS3S2A8.0A6.0NEW PROPOSED THIRD FLOORPLAN AND ROOF PLAN1# description datedate354plan checkclient reviewrevision history2dateconstructionbiddingarchproj projmgrnumprojscaledrawing release statusconsultantconsultantAS NOTEDsheetnumber4.19.2024Ken MacDonald'sResidenceApplicationPD-25-002Remodeling & Addition130 Vasona Oaks Dr,Los Gatos, CA 95032general notes1. This sheet is part of a set and is not to be used alone.2. This sheet is not to be used for construction unless thedesigner's signature appear on drawings and status boxindicates drawings have been released for construction.3. These plans and prints thereof, as instruments ofservice, are owned by the designer and are for use onthis project only. Reproduction and/or distribution withoutthe prior written consent of the designer is forbidden.4. Copyright Slcdesign, 2025xDo not scale or measure plan set.xAll vendors shall measure as builts/current framingconditions prior to casework/cabinet fabricationdisclaimerKITCHEN GENERAL NOTES (2022 CBC REQUIREMENTS):WATER CONSERVING PLUMBING FIXTURES REQUIREMENTS:• KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE. FLOWMAY TEMPORARILY INCREASE TO 2.2 GALLONS PER MINUTE, BUT MUST DEFAULT TO A MAXIMUM OF 1.8GALLONS PER MINUTE [CGBSC 4.303.1.4.4]• PRIOR TO FINAL INSPECTION ALL NON-COMPLIANT PLUMBING FIXTURES SHALL BE UPGRADEDWITH WATER-CONSERVING FIXTURES AS REQUIRED BY CIVIL CODE 1101.1. A COMPLETED AND SIGNEDCERTIFICATE OF COMPLIANCE SHALL BE PROVIDED TO THE BUILDING INSPECTOR.ELECTRICAL REQUIREMENTS:• RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL COUNTERTOPOR WORK SURFACE IS MORE THAN 24 INCHES FROM A RECEPTACLE IN THAT SPACE. [CEC 210.52(C)(1)]• RECEPTACLE OUTLETS SHALL BE INSTALLED AT EACH KITCHEN COUNTERTOP AND WORKSURFACE THAT IS 12 INCHES OR WIDER. [CEC 210.52(C)(1)]• AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH ISLAND OR PENINSULARCOUNTER SPACE WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12INCHES OR GREATER. [CEC 210-52(C)(2) AND 210.52(C)(3)]• ALL ELECTRICAL OUTLETS SERVING KITCHEN COUNTERTOPS AND DISHWASHERS SHALL BE GFCIPROTECTED. GROUND FAULT CIRCUIT INTERRUPTERS SHALL BE LOCATED IN A READILY ACCESSIBLELOCATION. [CEC 210.8(A)(D)]• AT LEAST TWO SEPARATE 20-AMPERE BRANCH CIRCUITS SHALL BE PROVIDED FOR SMALLKITCHEN APPLIANCES. THESE CIRCUITS ARE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETSONLY AND CANNOT SERVE DISHWASHER, MICROWAVE, RANGE HOOD, GARBAGE DISPOSAL, ETC.[CEC 210.11(C)(1) AND 210.52(B)(3)]• ALL ADDED/REPLACED RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES ANDSHALL BE ARC FAULT PROTECTED. [CEC 406.12]2022 BATHROOM REMODEL REQUIREMENTS:1. PROVIDE WATERPROOFED MATERIAL AT SHOWER WALLS.2. ALL RECEPTACLES SHALL BE GFCI PROTECTED AND CONNECTED TO A DEDICATED 15 AND 20 AMPS CIRCUIT ÂCEC 210.8Ã3. ALL HARDWIRED LIGHTING SHALL BE HIGH EFFICACY. ÂCA ENERGY EFF. STANDARDS, SECTION 150(K))4. EXHAUST FANS ARE REQUIRED IN ALL BATHROOMS, EVEN IF AN OPERABLE WINDOW IS INSTALLED. CRC 303.3\5. EXHAUST FANS AND LIGHTING SHALL HAVE SEPARATE CONTROL SWITCHES, (EVEN IF A COMBINATION UNIT IS INSTALLED). THEEXHAUST FAN MAY NEED TO BE SUPPLIED BY A GFCI PROTECTED CIRCUIT BASED ON THE MANUFACTURER’FS REQUIREMENTS. CEC150.0 (K)(2B)6. EXHAUST FANS SHALL TERMINATE A MINIMUM OF 3’F FROM PROPERTY LINE AND 3’F FROM OPENINGS INTO A BUILDING. (CMC502.2.1)7. EXHAUST FANS AT SHOWER SHALL BE LISTED FOR WET LOCATION AND SHALL BE GFCI PROTECTED. CEC 210.88. SHOWER ENCLOSURE DOORS SHALL OPEN OUTWARD AND MAINTAIN 22”H CLEARANCE CPC 408.59. SHOWER COMPARTMENT SHALL BE A MINIMUM 1,024 SQUARE INCHES ENCOMPASSING A 30”H CIRCLE. CPC 408.610. WATER CLOSETS (MAXIMUM 1.28 GPMÃ SHALL BE CLEAR 30 INCHES WIDE 15 INCHES ON CENTER) AND 24 INCHES IN FRONT. CPC402.511. SHOWER HEADS (MAXIMUM 1.8 GPM CPC 408.2 & FAUCETS (MAXIMUM 1.2 GPM CPC 407.2)12. BATHTUB/WHIRLPOOLS AND SHOWER VALVES SHALL BE APPROVED PRESSURE-BALANCED OR THERMOSTATIC MIXING TYPEADJUSTED TO A MAXIMUM OF 120 DEGREES. CPC 408.3electrical legendSSWITCH @ 48" U.F.F.(E) SMOKE AND CARBON MONOXIDE DETECTOR4" LED RECESSED LIGHT FIXTURE BATHROOM/EXHAUST FAN DUPLEX OUTLET @ 12" A.F.F. / 32"-36" A.F.F. AT COUNTER. G.F.I. OUTLET @ 32" - 36" A.F.F.G.F.IW/ LED LIGHT AND MOISTURE CONTROLVACANCY SENSOR SWITCH @ 48" A.F.F.SvGAS STUBLED WALL HUNG LIGHT FIXTURE BATHROOMLED RECESSED LIGHT FIXTURE WITH WATER PROOF LENSLED PENDANT LIGHT FIXTURE KITCHEN240V G.F.I. OUTLET @ 32" - 36" A.F.F.240V(E) STUD WALL TO REMAINlegend--DETAIL NUMBERSHEET NUMBEREXTERIOR ELEVATION REFERENCE TAG(N) 2x STUD WALL -EXTERIOR WALL TO RECEIVE 2X6 WITH R-13 BATT. INSULATION SEETITLE 24 FOR MORE INFO.new sheet notesWINDOW MODIFICATIONS: REPLACEMENT AND NEW WINDOWS:1. SHALL HAVE A U-FACTOR EQUAL TO 0.30 OR LOWER. EXCEPTIONS:REPLACEMENT SKYLIGHTS, OR NEW SKYLIGHTS UP TO 16 SQUARE FEET, MAY HAVE A U-FACTOR OF 0.55. WHEN 75 SQUARE FEET OR LESS OF FENESTRATION IS REPLACED WINDOWS MAY HAVE A U-FACTOR OF 0.40. [CENC 150.2(B) TABLE 150.1-A]2. FOR WINDOW MODIFICATIONS IN THE HILLSIDE FIRES ZONES 2 AND 3 REFER TO WINDOW ANDDOOR CODE COMPLIANCE CHECKLISTVENTILATION REQUIREMENTS:• TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS SHALL BE AT LEAST 3 FEET FROM PROPERTYLINE AND FROM OPENINGS INTO THE BUILDING, AND 10 FEET FROM A FORCED AIR INLET.[CMC 502.2.1]• WHOLE-BUILDING VENTILATION: KITCHENS REQUIRE VENTILATION AIR FLOW AT 100 CUBIC FEETPER MINUTE OR MORE FOR INTERMEDIATE SYSTEMS OR 5 AIR CHANGES PER HOUR FOR CONTINUOUS SYSTEMS. [ASHRAE 62.2]BUILDING ENVELOPE MODIFICATIONS:EXTERIOR WALL, FLOOR AND ROOF FRAMING SPACES OPENED UP DURING THE COURSE OF REMODELSHALL BE INSULATED. R-13 (2X4 WALL), R-20 (2X6 WALL), R-19 (FLOOR), AND R-19 (ATTIC/ROOF)INSULATION. [CENC 150.0(A)(C)(D)]LIGHTING REQUIREMENTS:• ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY. [CENC 150.0 TABLE 150.0-A]• UNDER CABINET LIGHTING SHALL BE CONTROLLED SEPARATELY FROM CEILING INSTALLEDLIGHTING SUCH THAT ONE CAN BE TURNED ON WITHOUT THE OTHER. [CENC 150.0(2)(K)]• LUMINARIES RECESSED INTO INSULATED CEILINGS:(A) SHALL BE LISTED FOR ZERO CLEARANCE INSULATION COVER (IC RATED);(B) SHALL INCLUDE A LABEL CERTIFYING AIR TIGHT (AT) WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS;(C) SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINARY HOUSING AND CEILING;(D) IF RECESSED LIGHTS ARE EQUIPPED WITH BALLASTS, SHALL ALLOW BALLAST MAINTENANCE ANDREPLACEMENT WITHOUT REQUIRING CUTTING OF HOLES IN THE CEILING; AND(E) SHALL NOT CONTAIN SCREW BASE SOCKETS. [CEES SEC.150(K)12].SMOKE ALARMS: DWELLINGS ARE TO BE EQUIPPED WITH SMOKE ALARMS INSTALLED IN THE FOLLOWING LOCATIONS: [CRC 314.4]• IN EACH EXISTING SLEEPING ROOM.• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.• ON EACH STORY INCLUDING BASEMENTS AND HABITABLE ATTICS, NOT INCLUDING CRAWLSPACES AND UNINHABITABLE ATTICS.• INSTALLED NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS WOULDPREVENT PLACEMENT OF A SMOKE ALARM REQUIRED BY CRC R314.3(4).CARBON MONOXIDE ALARMS: DWELLINGS THAT HAVE ATTACHED GARAGES WITH AN OPENING THAT COMMUNICATES WITH THE DWELLING UNIT, OR FUEL BURNINGAPPLIANCES, OR FIRE PLACE ARE TO BE EQUIPPED WITH CARBON MONOXIDE ALARMS INSTALLED INTHE FOLLOWING LOCATIONS: [CRC 315.3]• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.• ON EVERY OCCUPIABLE LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS.• WHERE A FUEL-BURNING APPLIANCE IS LOCATED WITHIN A BEDROOM OR ITS ATTACHED BATHROOM. A CARBON MONOXIDE ALARM SHALL BE INSTALLED WITHIN THEBEDROOM.ALARM INTERCONNECTION AND POWER: SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INTERCONNECTED SUCH THAT ACTIVATION OF ONE ALARM WILLACTIVATE ALL OF THE ALARMS AND SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING. EXCEPTION: WHERE REPAIRS OR ALTERATIONS TO EXISTINGBUILDINGS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHES AND THERE IS NO ACCESS BY MEANS OF ATTIC, BASEMENT OR CRAWL SPACE. [CRC 314.4 AND§314.6]SMOKE AND CARBON MONOXIDE DETECTORWHEN ALTERATIONS,REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, THE INDIVIDUAL DWELLINGUNIT SHALL BE EQUIPPED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. [R314.2.2]1. NEW RELOCATED WASHER. PROVIDE POWER2. PROVIDE WATER HAMMER ARRESTORS AT ALL APPLIANCES THAT HAVE QUICK-ACTING VALVES (I.E. DISHWASHER HOT WATER LINEAND THE HOT/COLD WATER LINES FOR THE CLOTHES WASHER.) 2022CPC 609.103. PROVIDE NEW DISHWASHER. PROVIDE POWER AND PLUMBING. ON THE DISCHARGE SIDE OF THE DISHWASHER PROVIDE A LISTEDAIR GAP FITTING. LISTED AIR GAPS SHALL BE INSTALLED WITH THE FLOOD LEVEL MARKING AT OR ABOVE THE FLOOD LEVEL OF THESINK OR DRAIN BOARD WHICHEVER IS HIGHER PER CPC SECTION 807.3.4. INSTALLATION OF A DEDICATED FUEL SHUT OFF VALVE SHALL BE WITHIN 6'-0" OF THE GAS APPLIANCE IT SERVES. CPC 230.79.EARTHQUAKE-ACTUATED GAS SHUTOFF VALVES DESIGNED TO AUTOMATICALLY SHUT OFF THE GAS AT THE LOCATION OF THEVALVE IN THE EVENT OF A SEISMIC DISTURBANCE AND CERTIFIED BY THE STATED ARCHITECT AS CONFORMING TO CALIFORNIACODE OF REGULATIONS, TITLE 24, PART 12, CHAPTER 12É16É1, SHALL BE INSTALLED IN ALL NEW BUILDINGS AND IN EXISTINGBUILDINGS THAT UNDERGO ALTERATIONS OR ADDITIONS THAT EXCEED $10,000.5. PROVIDE NEW GAS COOKING RANGE (PROVIDE POWER) WITH NEW EXHAUST HOOD (PROVIDE POWER) WITH A MIN. VENTILATIONEXHAUST RATE OF 100 CFM. HOUSEHOLD COOKING APPLIANCES SHALL HAVE A VERTICAL CLEARANCE ABOVE THE COOKING TOPOF NOT LESS THAN THIRTY - 30" INCHES TO COMBUSTIBLE MATERIAL OR METAL CABINETS, EXCEPT WHERE 24 INCHES IS ALLOWEDPER CODE OR MANUFACTURER'S SPECIFICATION. CMC 920.3.2.6. RANGE HOODS SHALL BE PERMITTED TO BE CORD-AND-PLUG-CONNECTED WITH A FLEXIBLE COURT IDENTIFIED AS SUITABLE FORUSE ON RANGE HOODS IN THE INSTALLATION INSTRUCTIONS OF THE APPLIANCE MANUFACTURER, WHERE ALL THE FOLLOWINGCONDITIONS ARE MET: THE FLEXIBLE CORD IS TERMINATED WITH A GROUNDING-TYPE ATTACHMENT PLUG. THE LENGTH OF THECORD IS 18 INCHES TO 4 FEET. RECEPTACLES ARE LOCATED TO PROTECT AGAINST PHYSICAL DAMAGE TO THE FLEXIBLE CORD.THE RECEPTACLES IS ACCESSIBLE. THE RECEPTACLE IS SUPPLIED BY AN INDIVIDUAL BRANCH CIRCUIT.7. IF OCCURS ELECTRIC STOVES AND OVENS SHALL BE SUPPLIED WITH 40- OR 50-AMP BRANCH CIRCUIT.8. PROVIDE NEW SINK WITH CALGREEN COMPLIANT FAUCET WITH NEW GARBAGE DISPOSAL (PROVIDE POWER).9. NEW REFRIGERATOR/ICE MAKER/WINE COOLER (PROVIDE POWER AND ICE MAKER OUTLET BOX AND CONNECT).10. NEW SOLID COUNTER TOP WITH UPPER AND LOWER CABINETS.11. COUNTERTOP AND WHERE THE COUNTERTOP DOES NOT EXTEND MORE THAN 6 INCHES BEYOND ITS BASE.12. NEW SOLID SURFACE COUNTER KITCHEN ISLAND AND BAR COUNTER WITH BASE CABINET.13. COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER SHALL PROTECT ALL RECEPTACLES IN ALL BEDROOMS, DINING ROOMS,LIVING ROOMS, PARLORS, LIBRARIES, DENS SUNROOMS, RECREATION ROOMS, CLOSETS, KITCHENS. LAUNDRY AREAS. HALLWAYSOR SIMILAR ROOMS OR AREAS WITH BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE-PHASE, 15 AND 20-AMPERE RECEPTACLEOUTLETS, AND BE READILY ACCESSIBLE. 2022 CEC SECTION 210.1214. TWO 20-AMP GFCI PROTECTED CIRCUITS WILL BE PROVIDED IN THE KITCHEN COUNTER AND ISLAND OUTLETS AND SHALL COMPLYWITH ART. 210.52 (C) (5) EXCEPTION TO (5) CEC 202215. LIGHTING INTEGRAL TO EXHAUST FANS SHALL BE CONTROLLED SEPARATELY FROM THE EXHAUST FANS. 150.0 (K) 28. LIGHTINGSHALL HAVE VACANCY SENSOR. EXHAUST FAN SHALL BE 50 CFM MIN.16. PROVIDE WATER CLOSETS TO BE MAX. 1.28 GAL. PER FLUSH.17. SHOWER/TUB W/ FULL HEIGHT TILE WALLS & TEMPERED GLASS ENCLOSURE. USE BITUTHANE 4,000 WATERPROOFING MEMBRANEOVER 1/2" WONDER BOARD & WALLS, CEILING, & FLOOR.18. NEW SOLID SURFACE (NON-SLIP RESISTANT) SHOWER PAN AND WALLS19. PROVIDE SHOWER FINISHED TO 72" ABOVE DRAIN. PROVIDE PRESSURE OR THERMOSTATIC MIXING VALUE @ SHOWER ANDJACUZZI/TUB, WHICH LIMITS WATER TEMPERATURE TO 120°F. SHOWER HEAD SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60PSI.20. NEW SINK AND FAUCET. PROVIDE FAUCET TO BE MAX 1.2 CMP AT 60 PSI.METERING FAUCETS SHALL NOT EXCEED 0.2 GALLONS PERMETERING CYCLE.21. WINDOW MODIFICATIONS: REPLACEMENT AND NEW WINDOWS: SHALL HAVE A U-FACTOR EQUAL TO 0.3022. PROVIDE NEW COMBO UNIT SMOKE DETECTOR AND CARBON MONOXIDE DETECTOR W/BATTERY BACK-UP IN HALLWAY.23. PROVIDE NEW 24" X 48" FLAT PROFILE SKYLIGHT.24. PROVIDE NEW TANKLESS WATER HEATER.25. NEW MIN. 36"x24" ATTIC ACCESS26. NEW PREFABRICATED STAIRS.27. NEW P.T. POSTS ON CONC. BASE 2" ABOVE FINISHED GRADE (TYP.)28. NEW DECKING OVER FRAMING. S.S.D. FOR FRAMING DETAILS.29. NEW AIR CONDITIONER.112SCALE: 1/4" = 1'-0" roof planN8A7.05A7.07A7.01A8.02A8.0(E) COMPOSITIONALROOFING TO REMAINNEW COMPOSITIONAL SHINGLES ROOFING OVERTWO LAYERS 30 LB FELT OVER 1/2" PLYWOOD.MINIMUM CLASS 'C' ROOFING PER CRC R902.1.3.MATCH WITH EXISTING ADJACENT.NEW PREFAB SUNROOM ROOF.CONTRACTOR TO PROVIDE SHOP DRAWINGSFOR CITY APPROVVAL(E) SKYLIGHTS TOREMAIN(E) SKYLIGHTS TOREMAIN2.5:12 SLOPERED DASHED LINESINDICATE ROOFOVERHANG TOREMOVE 4'-358"18'-038"8'-10"2'-334"7'-214"7'-1034"3'-4"6'-8"6'-10"26'-234"1'-8"6'-8"4'-10"16'-914"8'-10"13'-312"3'-4"25'-858"26'-0"21'-438"4'-0"6'-8"6'-4"1'-10"11'-1138"4'-10"3'-0"6'-8"8'-0"16'-0"10'-0"3'-1034"8'-1138"3'-8"4'-4"6'-2"8'-0"4'-0"3'-534"8'-10"7'-1034"9'-618"2'-6"19'-938"9'-1178"3'-8"4'-4"6'-2"8'-0"8'-10"7'-1034"2'-6"19'-938"9'-1178"7'-578"9'-618"11'-1138"3'-0"6'-8"8'-0"18'-918"4'-758"3'-1034"8'-1138"2'-714"4'-358"18'-038"8'-10"2'-334"7'-214"7'-1034"3'-4"6'-8"6'-10"26'-234"1'-8"6'-8"4'-10"16'-914"8'-10"13'-658"3'-4"25'-858"26'-0"21'-438"8'-0"9'-518"A7.0DEMO AND NEW ELEVATIONS1# description datedate354plan checkclient reviewrevision history2dateconstructionbiddingarchproj projmgrnumprojscaledrawing release statusconsultantconsultantAS NOTEDsheetnumber4.19.2024Ken MacDonald'sResidenceApplicationPD-25-002Remodeling & Addition130 Vasona Oaks Dr,Los Gatos, CA 95032general notes1. This sheet is part of a set and is not to be used alone.2. This sheet is not to be used for construction unless thedesigner's signature appear on drawings and status boxindicates drawings have been released for construction.3. These plans and prints thereof, as instruments ofservice, are owned by the designer and are for use onthis project only. Reproduction and/or distribution withoutthe prior written consent of the designer is forbidden.4. Copyright Slcdesign, 2025xDo not scale or measure plan set.xAll vendors shall measure as builts/current framingconditions prior to casework/cabinet fabricationdisclaimerdemo elevation - westdemo elevation - north demo elevation - south 5687demo elevation - east1243new elevation - westnew elevation - north new elevation - south new elevation - eastSCALE: 1/8" = 1'-0"(E) ROOF(E) WINDOW(E) STUCCO(E) STUCCO(E) POST TOREMOVESCALE: 1/8" = 1'-0"SCALE: 1/8" = 1'-0"SCALE: 1/8" = 1'-0"SCALE: 1/8" = 1'-0"SCALE: 1/8" = 1'-0"SCALE: 1/8" = 1'-0"SCALE: 1/8" = 1'-0"(E) WINDOW(E) DOOR(E) GARAGEDOOR(E) ROOF(E) STUCCO(E) WINDOW(E) DOOR(E) DOOR(E) ROOF(E) ROOF(E) WINDOW(E) WINDOW(E) ROOF TOREMOVE(E) WINDOW(E) STUCCO(N) POST(E) DOOR(E) ROOF(E) ROOF(E) WINDOW(E) WINDOW(N) ROOF(E) ROOF(E) ROOF TOREMOVE(E) WINDOW(E) WINDOW TOREMOVE(E) WINDOW TOREMOVE(E) WINDOW(E) STUCCO(E) POST TOREMOVE(E) DOOR(E) DOOR TOREMOVE(E) ROOF(N) ROOF(N) GLASSROOF(E) WINDOW(E) STUCCO(N) STAIR(E) DOOR(N) GLASSWALL(E) ROOF(E) ROOF TOREMOVE(E) WINDOW TOREMOVE(E) WINDOW(E) STUCCO(E) DECK TOREMOVE(E) POST TOREMOVE(E) WINDOW(E) ROOF(N) GLASS ROOF(N) GLASS WALL(E) WINDOW(E) STUCCO(N) STAIR(N) POST(E) WINDOW(E) ROOF(E) ROOF(E) GARAGEDOOR(E) WINDOWTO REMOVE(N) WINDOW1 16'-914"8'-10"8'-0"6'-8"6'-8"9'-078"3'-4"7'-434"6'-8"1'-0"7'-8"1'-0"8'-0"6'-10"8'-834"7'-1078"7'-6"(N) BEDROOM(E) LIVING ROOM/DINING(E) BEDROOM1'-0"(E) ENTRANCE(N) 1//2BATH3'-6"3'-0"TO TOP OFHANDRAIL(N) CLOSET RECONFLAUNDRYRM.8'-0"1'-0"8'-518"EXTENDED LIVING12" GYP BOARD. TYP.2xSTUDS @ 16" O.C.EXTERIOR WALLS WITHINSULATION. SEE T-24NEW RAFTERS WITH CLOSEDCELL INSULATION AT VAULTEDCEILING. SEE T-24(E) RAFTERS WITH CLOSED CELLINSULATION AT VAULTEDCEILING. SEE T-24PROVIDE NEW FLOORINSULATION ABOVEGARAGE AREA.SEE TITLE 24NEW 58" TYPE X GYP BORAD ATCEILING BETWEEN NEWLIVNG SPACE AT 2NDFLOOR AND (E) GARAGE(N) 2x BLOCKING W/2" DIAVENTILATION HOLES INBLOCKING. (3) PERBLOCK. TYP.(E) RIDGE BEAMPRE-FAB SPIRAL STAIRSDEFERRED SUBMITTAL(N) WOOD HANDRAILS ATTACHED TOWALL(SHOWN BEYOND) WALL IN FRONT(N) WOOD STAIRSS.S.D.3'-1034"7 RISER @ 6 58 "EACH5'-012"6 TREADS@ 10" EACHMARKD1WIDTHLOCATIONQUANTITYCOMMENTSD2D3D4DOOR AND WINDOW SCHEDULE6' - 0"(N) SUNROOMHEIGHT6' - 8"126' - 8"2' - 8" 6' - 0"(N) CLOSET16' - 8"86' - 8"2' - 6"SLIDINGDOOR4' - 2"(N) BEDROOM14' - 6"RECONFLAUNDRT RM.FOLDINGTEMPEREDDOOR(E) BEDROOM,(N) BEDROOM,(N) BATHROOM,(N) W.I.C.SINGLEPANEL SOLIDDOORW1SLIDINGEGRESSWINDOWOPEN GUARDRAILS AND OPENHANDRAILS ONDECKS AND STAIRWAYSMORE THAN 30 INCHESABOVE GRADEOR A FLOOR BELOW SHALLHAVEMEMBERS SPACED SO THAT A 4INCH DIAMETERSPHERE CANNOT PASSTHROUGH.GUARDRAILHANDRAILS.34-38"above nosings11" MIN. RUNLESS THAN 4"OPENINGWHEREHIGHER THAN30"ABOVE THE GROUND7 3/4" MAX.RISENOT LESS THANWIDTHOF STAIRWAYLANDINGFINISHED GRADEGUARDRAIL REQUIREDIFMORE THAN 30"DECKLESS THAN6"DIA. SPACENEWOREXISTINGLIGHTREQUIRED42" MIN HEIGHTSTAIRS SEEELEVATIONS ANDPLANSGUARDRAIL DETAIL8'-0"8'-0"8'-6"EXTENDED AREA(N) SUNROOM12" GYP BOARD. TYP.2xSTUDS @ 16" O.C.EXTERIOR WALLS WITHINSULATION. SEE T-24(N) 2x FLOOR JOIST,S.S.D. INSULATIONSEE T241'-6"CLR.NEW RAFTERS WITH CLOSEDCELL INSULATION AT VAULTEDCEILING. SEE T-24(E) RAFTERS WITH CLOSED CELLINSULATION AT VAULTEDCEILING. SEE T-248'-0"8'-0"6'-8"(E) BEDROOMA8.0SECTIONS , DOOR AND WINDOWSCHEDULE AND DETAIL1# description datedate354plan checkclient reviewrevision history2dateconstructionbiddingarchproj projmgrnumprojscaledrawing release statusconsultantconsultantAS NOTEDsheetnumber4.19.2024Ken MacDonald'sResidenceApplicationPD-25-002Remodeling & Addition130 Vasona Oaks Dr,Los Gatos, CA 95032general notes1. This sheet is part of a set and is not to be used alone.2. This sheet is not to be used for construction unless thedesigner's signature appear on drawings and status boxindicates drawings have been released for construction.3. These plans and prints thereof, as instruments ofservice, are owned by the designer and are for use onthis project only. Reproduction and/or distribution withoutthe prior written consent of the designer is forbidden.4. Copyright Slcdesign, 2025xDo not scale or measure plan set.xAll vendors shall measure as builts/current framingconditions prior to casework/cabinet fabricationdisclaimer2SCALE: 3/16" = 1'-0"section b-bdoor and window schedulestairs and guardrail details3SCALE: 3/4" = 1'-0"4SCALE: 3/8" = 1'-0"stair general notes1. STAIR TREADS AND RISERS: STAIR RISER HEIGHTS SHALL BE 7 34 INCHES MAXIMUM AND 4INCHES MINIMUM. STAIR TREAD DEPTHS SHALL BE 10 INCHES MINIMUM. THE RISERHEIGHT SHALL BE MEASURED VERTICALLY BETWEEN THE LEADING EDGES OF ADJACENTTREADS. THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THEVERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AND AT ARIGHT ANGLE TO THE TREAD'S LEADING EDGE. WINDER TREADS SHALL HAVE A MINIMUMTREAD DEPTH OF 10 INCHES MEASURED AT A RIGHT ANGLE TO THE TREAD'S LEADINGEDGE AT THE WALKLINE. WINDER TREADS SHALL HAVE A MINIMUM TREAD DEPTH OF 6" ATANY POINT IN THE CLEAR WIDTH OF THE STAIR.2. STAIRWAY LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM OFEACH STAIRWAY. THE WIDTH OF THE LANDINGS SHALL NOT BE LESS THAN THE WIDTH OFSTAIRWAYS THEY SERVE. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION OF 36"MEASURED IN THE DIRECTION OF TRAVEL.3. ENCLOSURES UNDER STAIRWAYS. THE WALLS AND CEILING WITHIN ENCLOSED USABLESPACES UNDER ENCLOSED AND UNENCLOSED STAIR- WAYS SHALL BE PROTECTED ONTHE ENCLOSED SIDE WITH 12 INCH GYPSUM BOARD. THERE SHALL BE NO ENCLOSEDUSABLE SPACE UNDER EXTERIOR EXIT STAIRWAYS UNLESS THE SPACE IS COMPLETELYEN- CLOSED IN 1-HOUR FIRE-RESISTIVE RATED CONSTRUCTION. THE OPEN SPACE UNDEREXTERIOR STAIRWAYS SHALL NOT BE USED FOR ANY PURPOSE.4. HANDRAIL HEIGHT: HANDRAIL HEIGHT, MEASURED ABOVE STAIR TREAD NOSING, OR FINISHSURFACE RAMP SLOPE SHALL BE UNIFORM, NOT LESS THAN 34 INCHES AND NOT MORETHAN 38 INCHES.5. HANDRAIL GRIP-SIZE: HANDRAILS WITH A CIRCULAR CROSS- SECTION SHALL HAVE ANOUTSIDE DIAMETER OF AT LEAST 1.25 INCHES AND NOT GREATER THAN 2 INCHES ORSHALL PROVIDE EQUIVALENT GRIP-SIZE. IF THE HANDRAIL IS NOT CIRCULAR, IT SHALLHAVE A PERIMETER DIMENSION OF AT LEAST 4 INCHES AND NOT GREATER THAN 6.25INCHES WITH A MAXIMUM CROSS-SECTION DIMENSION OF 2.25 INCHES. EDGES SHALLHAVE A MINIMUM RADIUS OF 0.01 INCH.guardrail general notes1. CONFORM TO 2019 CRC R301.5. HANDRAILS AND GUARDS SHALL BE DESIGNED TO RESISTA CONCENTRATED LOAD OF 200LB APPLIED IN ANY DIRECTION. [CRC R301.5]2. GUARDRAILS ARE REQUIRED ALONG OPEN SIDES OF STAIRWAYS, LANDINGS, BALCONIES,PORCHES, DECKS, FLOOR OPENINGS, RAMPS, AND ROOFS USED FOR OTHER THANSERVICE OF THE BUILDING, WHICH ARE MORE THAN 30" ABOVE GRADE OR FLOOR BELOW.3. GUARDRAILS SHALL HAVE A 42" MINIMUM HEIGHT, 42" HIGH ALONG OPEN SIDES OFSTAIRWAYS.4. GUARDRAILS MUST BE ABLE TO WITHSTAND A LOAD OF 20 POUNDS PER LINEAL FOOTAPPLIED HORIZONTALLY AT THE TOP OF THE GUARDRAIL.5. INTERMEDIATE RAILS, PANELS OR FILLERS, AND THEIR CONNECTIONS, SHALL BECAPABLE OF WITHSTANDING A LOAD OF 25 POUNDS PER SQUARE FOOT APPLIED ATRIGHT ANGLES TO THE GUARDRAIL.6. GUARDRAILS SHALL BE DESIGNED SO THAT A 6" DIAMETER SPHERE CANNOT PASSTHROUGH THE TRIANGULAR SPACE FORMED BY THE BOTTOM OF THE RAIL, THE RISERAND THE TREAD.7. BALUSTERS ON A HANDRAIL OR A GUARDRAIL SHALL BE SO SPACED SO THAT A 4"SPHERE CANNOT PASS THROUGH.1SCALE: 3/16" = 1'-0"section a-a1 UP30"x80"FRIDGEPANTRYwetbar areawinefridge30"x80"makeup30"x80"30"x80"D / W D1D1D3D3D3D3192"x80"(N) FOLDING DOORSTEMPERED-5 EQ. PANELS192"x80"(N) FOLDING DOORSTEMPERED EQ. PANELS30"x80"D3B(N) ADDITION91 S.F.A(E) HOUSE1087 S.F.C(N) SUN ROOM231 S.F.32"x80"72"x80"(N)TANKLESSW.H.WINE CELLAR @ FINISHED CRAWLSPACE BELOW GARAGE FLOORD4D230"x80"D3 (N)WATERSOFTENERE(N) COVEREDPATIO173 S.F.A(E) HOUSE592 S.F.B(E) ENTRY86 S.F.C(E) GARAGE464 S.F.D(E) PATIO148 S.F.DN.50"x54"(n) sliding wdwegress30"x80"30"x80"30"x80"(N) ATTICAIR HANDLINGUNIT24"X24"(n) flat profileskylightW1D3D3D396"x48"(n) fixedw/smart glass A(N)ADDITION S.F.BSTAIRADDITION50 S.F.(E) HALLAND BATH BELOWBEDROOMBELOWLIVING ROOMBELOWSUN ROOMBELOWC(E) REMODELING108 S.F.DMEZZANINETO BE REMOVED64 S.F.PROPOSED TOOPEN TO BELOWLOTS SIZEEXISTING 1STFLOOR PLAN W/GARAGEBTOTALAREA DETAILSAEXISTING 2NDFLOOR PLANTOTALAEXISTING 3RDFLOOR PLAN -MEZZANINE1977 SQ.FT.AREA OF WORKWITHIN EXISTINGINTERIOR OF THE1ST FLOOR1290 SQ.FT. 126 SQ.FT.592 SQ.FT86 SQ.FT.1463 SQ.FT.1087 SQ.FT.786 SQ.FT1087 SQ.FT.91 SQ.FT.1409 SQ.FT.172 SQ.FT. -64 S.F. (SEE DBELOW)108 SQ.FT.170 SQ.FT.50 SQ.FT.329 SQ.FT.AREA OF WORKWITHIN EXISTINGINTERIOR OF2ND FLOORDC464 SQ.FT.148 SQ.FT.TOTAL1ST+2ND+3RD=1463+1409+329/1977=3201/1977 = 161.9%E173 SQ.FT.231 SQ.FT.BCABAREA OF WORKWITHIN EXISTINGINTERIOR OFMEZZANINE108 SQ.FT.C-64 SQ.FT.DTOTAL1# description datedate354plan checkclient reviewrevision history2dateconstructionbiddingarchproj projmgrnumprojscaledrawing release statusconsultantconsultantAS NOTEDsheetnumber4.19.2024Ken MacDonald'sResidenceApplicationPD-25-002Remodeling & Addition130 Vasona Oaks Dr,Los Gatos, CA 95032general notes1. This sheet is part of a set and is not to be used alone.2. This sheet is not to be used for construction unless thedesigner's signature appear on drawings and status boxindicates drawings have been released for construction.3. These plans and prints thereof, as instruments ofservice, are owned by the designer and are for use onthis project only. Reproduction and/or distribution withoutthe prior written consent of the designer is forbidden.4. Copyright Slcdesign, 2025xDo not scale or measure plan set.xAll vendors shall measure as builts/current framingconditions prior to casework/cabinet fabricationdisclaimerresponse to planning 5.2025response to planning 6.9.20251SCALE: 1/4" = 1'-0"first floor planN2SCALE: 1/4" = 1'-0"second floor planN3SCALE: 1/4" = 1'-0"third floor planNA9.0AREA DIAGRAM111