08-27-25 Packet - HPCPage 1
HOW TO PARTICIPATE
The Town of Los Gatos strongly encourages your active participation in the public process. If
you are interested in providing oral comments during the meeting, you must attend in-
person, complete a speaker’s card, and return it to the staff. If you wish to speak to an item
on the agenda, please list the item number on the speaker card. The time allocated to
speakers may change to better facilitate the meeting. If you are unable to attend the meeting
in-person, you are welcome to submit written comments via email to
planning@losgatosca.gov.
Public Comment During the Meeting:
When called to speak, please limit your comments to three (3) minutes, or such other time as
the Chair may decide, consistent with the time limit for speakers at a Town meeting.
Speakers at public meetings may be asked to provide their name and to state whether they
are a resident of the Town of Los Gatos. Providing this information is not required.
Deadlines to Submit Written Comments:
If you are unable to participate in person, you may email planning@losgatosca.gov with the
subject line “Public Comment Item #_” (insert the item number relevant to your comment).
Persons wishing to submit written comments to be included in the materials provided to the
Commission must provide the comments as follows:
For inclusion in the agenda packet: by 11:00 a.m. the Friday before the Committee
meeting.
For inclusion in the agenda packet supplemental materials: by 11:00 a.m. on the
day of the Committee meeting.
For inclusion in a desk item: by 11:00 a.m. the day of the Committee meeting.
TOWN OF LOS GATOS
HISTORIC PRESERVATION COMMITTEE
AUGUST 27, 2025
110 EAST MAIN STREET
TOWN COUNCIL CHAMBERS
4:00 PM
Lee Quintana, Chair
Martha Queiroz, Vice Chair
Susan Burnett, Planning Commissioner
Emily Thomas, Planning Commissioner
Alan Feinberg, Committee Member
Page 1
Page 2
CALL MEETING TO ORDER
ROLL CALL
CONSENT ITEMS (Items appearing on the Consent Items are considered routine Town business
and may be approved by one motion. Any member of the Committee may request to have an
item removed from the Consent Items for comment and action. Members of the public may
provide input on any or multiple Consent Item(s) when the Chair asks for public comments on the
Consent Items. If you wish to comment, please follow the Participation Instructions contained on
Page 1 of this agenda. If an item is removed, the Chair has the sole discretion to determine when
the item will be heard.)
1. Draft Minutes of the August 27, 2025, Historic Preservation Committee Meeting
VERBAL COMMUNICATIONS (Members of the public are welcome to address the Historic
Preservation Committee on any matter that is not listed on the agenda and is within the subject
matter jurisdiction of the Committee. To ensure all agenda items are heard, this portion of the
agenda is limited to 30 minutes. In the event additional speakers were not able to be heard during
the initial Verbal Communications portion of the agenda, an additional Verbal Communications will
be opened prior to adjournment. Each speaker is limited to three minutes or such time as authorized
by the Chair.)
PUBLIC HEARINGS (Applicants and their representatives may be allotted up to a total of five
minutes maximum for opening statements. Members of the public may be allotted up to three
minutes to comment on any public hearing item. Applicants and their representatives may be
allotted up to a total of three minutes maximum for closing statements. Items
requested/recommended for continuance are subject to the Committee’s consent at the meeting.)
2. Consider a Request for Approval to Construct Exterior Alterations to an Existing
Contributing Single-Family Residence in the Broadway Historic District on Property Zoned
R-1D:LHP. Located at 68 Broadway. APN 510-45-085. Request for Review HS-25-035.
Exempt Pursuant to CEQA Guidelines, Section 15301: Existing Facilities. Property
Owner/Applicant: Marc Dubresson. Project Planner: Samina Merchant.
3. Consider a Request for Approval to Construct Exterior Alterations (Window Replacement)
to an Existing Pre-1941 Single-Family Residence on Property Zoned R-1:8. Located at
16760 Magneson Loop. APN 523-06-015. Request for Review Application PHST-25-014.
Exempt Pursuant to CEQA Guidelines, Section 15301: Existing Facilities. Property
Owner/Applicant: Mickael Forsman. Project Planner: Maria Chavarin.
4. Consider a Request to Remove a Pre-1941 Property from the Historic Resources Inventory
for Property Zoned R-1D. Located at 24 Pleasant Street. APN 529-26-016. Request for
Review PHST-25-013. Exempt Pursuant to CEQA Guidelines, Section 15061 (b)(3). Property
Owner/Applicant: Swapnil Raut and Rashmi Jadhav. Project Planner: Suray Nathan.
Page 2
Page 3
OTHER BUSINESS (Up to three minutes may be allotted to each speaker on any of the following
items.)
5. Consider a Request for Preliminary Review to Construct a New Second-Story Addition and
Exterior Alterations to an Existing Pre-1941 Single-Family Residence on Property Zoned R-
1D. Located at 245 Los Gatos Boulevard. APN 529-24-024. Request for Review Application
PHST-25-011. Exempt Pursuant to CEQA Guidelines, Section 15301: Existing Facilities.
Property Owner: Michael Phung. Applicant: Andres Johnson. Project Planner: Samina
Merchant.
6. Consider a Request for Preliminary Review to Construct an Addition with Reduced
Setbacks to an Existing Noncontributing Single-Family Residence Located in the Almond
Grove Historic District on Nonconforming Property Zoned R-1D:LHP. Located at 321
Bachman Avenue. APN 510-17-100. Exempt Pursuant to CEQA Section 15301: Existing
Facilities. Request for Review Application PHST-25-016. Property Owner: Stanley and Jean
Melax. Applicant: Jennifer Kretschmer, AIA. Project Planner: Sean Mullin.
REPORT FROM THE DIRECTOR OF THE COMMUNITY DEVELOPMENT
COMMITTEE MATTERS
ADJOURNMENT
ADA NOTICE In compliance with the Americans with Disabilities Act, if you need special assistance
to participate in this meeting, please contact the Clerk’s Office at (408) 354-6834. Notification at
least two (2) business days prior to the meeting date will enable the Town to make reasonable
arrangements to ensure accessibility to this meeting [28 CFR §35.102-35.104].
NOTE The ADA access ramp to the Town Council Chambers is under construction and will be
inaccessible through June 2025. Persons who require the use of that ramp to attend meetings are
requested to contact the Clerk’s Office at least two (2) business days prior to the meeting date.
Page 3
This Page
Intentionally
Left Blank
Page 4
110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874
www.losgatosca.gov
TOWN OF LOS GATOS
HISTORIC PRESERVATION
COMMITTEE REPORT
MEETING DATE: 08/27/2025 ITEM: 1
DRAFT
MINUTES OF THE HISTORIC PRESERVATION COMMITTEE MEETING
JUNE 25, 2025
The Historic Preservation Committee of the Town of Los Gatos conducted a regular meeting on
June 25, 2025 at 4:00 p.m.
MEETING CALLED TO ORDER AT 4:00 PM
ROLL CALL Present: Chair Lee Quintana, Vice Chair Martha Queiroz, and Planning Commissioner Susan
Burnett.
Absent: Planning Commissioner Emily Thomas and Committee Member Allen Feinberg.
VERBAL COMMUNICATIONS
None.
CONSENT ITEMS (TO BE ACTED UPON BY A SINGLE MOTION)
1. Approval of Minutes – May 28, 2024 MOTION: Motion by Commissioner Burnett to approve the Consent Calendar.
Seconded by Vice Chair Queiroz.
VOTE: Motion passed unanimously 3-0.
PUBLIC HEARINGS 2. Consider a Request for Approval to Construct Exterior Alterations (Window
Repair/Replacement) to a Contributing Multi-Family Residence in the Fairview Plaza
Historic District on Property Zoned R-1:8:LHP. Located at 95 Fairview Plaza. APN 510-
43-018. Minor Development in an Historic District Application HS-25-027. Categorically
Exempt Pursuant to the California Environmental Quality Act (CEQA) Guidelines, Section
15301: Existing Facilities. Property Owner/Applicant: Matthew Reynolds. Project
Planner: Maria Chavarin.
Page 5
PAGE 2 OF 11 MINUTES OF THE HISTORIC PRESERVATION COMMITTEE MEETING OF JUNE 25, 2025
Sean Mullin, Planning Manager
This item has been removed from the Historic Preservation Committee Agenda for June
25, 2025. Staff re-evaluated the proposed project and determined that the work falls under the
Minor Repair clause of Section 4.3 of the Residential Design Guidelines, which states that if
minor repair work is proposed and the materials will be replaced in kind, only a Building Permit
will be required.
3. Consider a Request for Approval to Construct Exterior Alterations (Window
Replacement) to an Existing Single-Family Residence on Property Zoned R-1:8. Located
at 121 Loma Alta Avenue. APN 532-29-083. Request for Review Application PHST-25-
012. Exempt Pursuant to CEQA Guidelines, Section 15301: Existing Facilities. Property
Owner: Jim Wilson. Applicant: Renewal by Andersen/Hilda Ramirez. Project Planner:
Sean Mullin.
Sean Mullin, Project Planner, presented the staff report.
Chair Quintana
Will postpone Item 3 until the applicant arrives and move on to Item 4.
4. Consider a Request for Approval to Construct a Second-Story Addition of 100 Square
Feet and Exterior Alterations to an Existing Noncontributing Single-Family Residence in
the University-Edelen Historic District on Property Zoned R-1D:LHP. Located at 117
Edelen Avenue. APN 529-02-020. Minor Development in a Historic District Application
HS-25-030. Categorically Exempt Pursuant to the California Environmental Quality Act
(CEQA) Guidelines, Section 15310: Existing Facilities. Property Owner: Jeff and Julie
Prince. Applicant: David Kuoppamaki. Project Planner: Maria Chavarin.
Maria Chavarin, Project Planner, presented the staff report.
Note: This is not a request for a formal review but for a second preliminary review.
Sean Mullin, Planning Manager
As a preliminary review, there is no formal recommendation from the Committee. They
can provide additional feedback and evaluate if the applicant adequately responded to the first
preliminary review. The applicant decides when to submit a formal application.
Committee members asked questions of staff.
Sean Mullin, Planning Manager
There is no formal application yet. Focus on the changes from the first preliminary
review. Have they responded adequately? There is no technical analysis at this stage of
preliminary review. In 1989 the building was demolished but property is still in the University-
Edelen Historic District. It should still support the district by being consistent and enhance the
District.
Page 6
PAGE 3 OF 11 MINUTES OF THE HISTORIC PRESERVATION COMMITTEE MEETING OF JUNE 25, 2025
Opened Public Comment.
David Kuoppamaki, Applicant
David sees his role as a mediator between what the client wants and to still abide by the
zoning and historic codes. The owners like the look of their neighbor’s house.
Committee members asked questions of staff.
Sean Mullin, Planning Manager
This is not a new build but was rebuilt in 2000. Any improvements should continue to
enhance or be supportive of the District. It should be consistent with the District and the
chosen style. Guidelines allow in some cases, that it is possible to change a noncontributing
structure to a contributor. But in this case, this is not an old house, but a new house. With
guidance, the style of the house can change.
Committee members asked questions of the applicant.
David Kuoppamaki, Applicant
The owners want to change the style. They like the neighbor’s house and specifically
want a higher ceiling. The Prairie or Italianate style allows higher ceilings. They can play with
the roof pitch and ceiling heights. The owners would be open to a different potential style if
they can get a higher ceiling. On the second floor the side walls come down very low to only
five feet. This makes it difficult to accommodate a TV or a dresser.
Closed Public Comment.
Committee members discussed the matter.
Commissioner Burnett
Don’t want to change the style from Victorian to Italianate. The flat roof doesn’t go
along with the gable roof.
Sean Mullin, Planning Manager
Let’s walk through the bullet list:
• Adding two windows instead of one in the front elevation. – done.
• Consider adding a belly band to break up the first and second floor space on the
left elevation – done.
Chair Quintana
A belly band is usually used when there is a change in material.
Page 7
PAGE 4 OF 11 MINUTES OF THE HISTORIC PRESERVATION COMMITTEE MEETING OF JUNE 25, 2025
Vice Chair Queiroz
Agree with applicant, that there is a variety of house styles. There are many Victorians,
and there are variations of Italianate. At the last meeting we didn’t know that they were going
for Italianate. It is okay as long as it looks historic and fits with the neighborhood. Okay with
removing the windows. They are not visible. Looking at the floor plan it makes sense why they
wouldn’t want windows there.
Commissioner Burnett
This proposed design doesn’t have a single style. It should be true to its design.
Chair Quintana
The two sides of the street are different. The east side has a large apartment complex
and a few cottage style houses. The other side is more uniform. Between Miles and the end of
the street, there are a variety of cottage styles, but they are consistent in size. Two large
impressive Victorian Homes are on the south side of Miles Road. The main style is Italianate. It
is hard to say if there are Victorian or Craftsman leanings. No real example of an Italianate style
would fit into the neighborhood. Only the mix of the neighbor’s house.
Vice Chair Queiroz
It looks very similar to Italianate. It looks historic.
Chair Quintana
Advise the applicant to move in a different direction. Most of the houses are small and
simple like a bungalow, cottage, etc. This plan is not small or consistent.
Open Public Comment
David Kuoppamaki, Applicant
It is over FAR because of the basement square footage. It counts when the walls are 5
feet high.
Sean Mullin, Planning Manager
As a FAR exception, it would return to HPC and then to PC.
David Kuoppamaki, Applicant
The Lot coverage is not an issue in this zone. The client’s primary goal is to go up and not
out.
Sean Mullin, Planning Manager
To summarize: Removal of windows on the left side is of mixed opinion. There is also
mixed opinion if this design works. Design can move towards Italianate as long as it’s done well
and right. A style needs to be defined and done well.
Page 8
PAGE 5 OF 11 MINUTES OF THE HISTORIC PRESERVATION COMMITTEE MEETING OF JUNE 25, 2025
Chair Quintana
The mass and scale changes the character of the street.
Vice Chair Queiroz
Bigger homes have been allowed on other historic streets. People want bigger homes. It
should be allowed as long as it is done well.
Sean Mullin, Planning Manager
Whatever style is chosen, do it well and right and be sensitive to the mass and scale of
the neighborhood.
Return to Item 3. The applicant is present.
3. Consider a Request for Approval to Construct Exterior Alterations (Window
Replacement) to an Existing Single-Family Residence on Property Zoned R-1:8. Located
at 121 Loma Alta Avenue. APN 532-29-083. Request for Review Application PHST-25-
012. Exempt Pursuant to CEQA Guidelines, Section 15301: Existing Facilities. Property
Owner: Jim Wilson. Applicant: Renewal by Andersen/Hilda Ramirez. Project Planner:
Sean Mullin.
Sean Mullin, Project Planner, presented the staff report.
Opened Public Comment.
Anita Reyes, Representative from Renewal by Andersen
The Committee has approved Fibrex for other properties. The owner likes that it is
energy efficient. Fibrex is a wood composite. It consists of 20% wood. It can be painted.
Closed Public Comment.
MOTION: Motion by Commissioner Burnett to recommend approval to the
Director for the above request. Seconded by Vice Chair Queiroz.
VOTE: Motion passed unanimously 3-0.
4. Consider a Request for Approval to Construct Exterior Alterations to an Existing
Contributing Single-Family Residence in the Broadway Historic District on Property
Zoned R-1D:LHP. Located at 68 Broadway. APN 510-45-085. Request for Review HS-25-
031. Exempt Pursuant to CEQA Guidelines, Section 15301: Existing Facilities. Property
Owner/Applicant: Marc Dubresson. Project Planner: Samina Merchant.
Samina Merchant, Project Planner, presented the staff report.
Page 9
PAGE 6 OF 11 MINUTES OF THE HISTORIC PRESERVATION COMMITTEE MEETING OF JUNE 25, 2025
Opened Public Comment.
Committee members asked questions of Staff.
Chair Quintana
The front and west side of the house is painted white. Was that original? In the 1980’s,
it was in the Historic district in 1980 when the modifications were done. A piece of paper
showed crossed out that the siding was to be replaced with matching brick and stucco. How do
we apply those considerations? We don’t know what was approved.
Sean Mullin, Planning Manager
Note that the 2011 application says to match the existing brick and stucco.
Erin Walters, Senior Planner
On page 289, there is a description of the history of Broadway. In the fourth paragraph
it describes that they reoriented the house to face Main Street. In 1987 they added to the right
with an external passage. It suffered extensive damage during the earthquake. Expanded the
kitchen and created a new master suite.
Marc Dubresson, Applicant/Owner
They are proposing to modify the rear of the house. It will be respectful of the home’s
historic character and the integrity of the surrounding neighborhood. It is not visible from the
street or surrounding properties. This is a private part of the lot. Over the year, they
thoughtfully separated the lot from the street, installed a pool, created a patio, and built a patio
cover structure.
They want to widen the rear opening from the kitchen to the garden and pool area. They want
to center the doorway for better architectural balance and install a beautiful color stacking
door system. All the brickwork and detailing will be retained with matching materials. The
practical purpose is to increase the natural light into the currently dark kitchen. These updates
will protect what is publicly visible and historically significant while providing modern comforts.
In the back, there is stucco, brick and painted wood. In the northern part of Brittany sometimes
you will see all brick, but there is usually white stucco and wood. Their house has a mix of these
two Normandy styles. They would like to carry on with the brickwork. They would center the
window and reuse the brick. On the side it is white stucco. They would match was there. It was
painted white when they bought the house. They would prefer to see the wood showing but
only if they were doing a full renovation to the front and back.
Questions for the Applicant
Vice Chair Queiroz
Do you plan to keep the wood band above the new door?
Page 10
PAGE 7 OF 11 MINUTES OF THE HISTORIC PRESERVATION COMMITTEE MEETING OF JUNE 25, 2025
Marc Dubresson, Applicant/Owner
Yes, to center the design over the opening. Most of the budget is going towards
installing a beam. Behind the band will be a steel beam to hold the house up.
Closed Public Comment.
Committee members discussed the matter.
Vice Chair Queiroz
Unless a home has special designation, homeowners should be able to add these kinds
of doors to the back of the home. The design looks nice. I’m in support of the proposal.
Committee asked question of Staff
Chair Quintana
When was Broadway designated as a historic district? Was this a landmark house?
Sean Mullin, Planning Manager
Not sure. Some homes were designated as landmarks before the districts became
historic. Those individual designations were rescinded when the districts became adopted as
historic. Don’t know if this was a landmark. This is a contributor.
Chair Quintana
This is a unique house in Los Gatos. The architectural style is unique. It was built and
designed by the owners. It deserves landmark designation. We need to consider both the
visible and not visible portions of the home. Not opposed to adding natural light, but the style
of the door, that is folding and has clear glass from top to bottom, it totally changes the exterior
of the back of this spectacular house.
Commissioner Burnett
Are the doors clear glass from top to bottom? Could they find folding doors that have
lites?
Chair Quintana
The other doors in the house are more in-keeping with the house. It is the character and
scale of the doors.
Vice Chair Queiroz
There are other homes in the Almond Grove that have those kinds of doors.
Chair Quintana
Yes, but this home is of a different level of historic significance.
Page 11
PAGE 8 OF 11 MINUTES OF THE HISTORIC PRESERVATION COMMITTEE MEETING OF JUNE 25, 2025
Commissioner Burnett
It looks modern.
Marc Dubresson, Applicant/Owner
Proposing modernization of the rear. The patio is a modern touch but what we enjoy.
Those windows don’t come in French door style. Matching the colors and materials. Increasing
the brick on both sides to make it part of the design of the house.
Vice Chair Queiroz
There are other versions available. They picked the least modern style offered by the
company.
MOTION: Motion by Vice Chair Queiroz to forward a recommendation of approval
of the above request to the Community Development Director.
There was no second.
VOTE: Motion fails.
Committee members discussed the matter.
Vice Chair Queiroz
Look into some other brands or can be custom made. Jay Plett works with a window
company called Bend Rivers that makes a window that you should investigate.
Commissioner Burnett
Recommend looking at another vendor for options.
Chair Quintana
The house is very special. Prefer doors with panes. Folding doors are much wider and
dominating.
Commissioner Burnett
They can try another type of door with screens for indoor and outdoor effects.
Sean Mullin, Planning Manager
Different members say that it is not the folding operation of the door, but the style,
portion of glass, and scale that is the concern. Suggest that the applicant explore other
manufacturers to see if they can find other doors with more lites or have something made. The
Committee can ask the applicant if they want a recommendation or have a continuance to do
some more research and come back in August
Opened Public Comment.
Page 12
PAGE 9 OF 11 MINUTES OF THE HISTORIC PRESERVATION COMMITTEE MEETING OF JUNE 25, 2025
Marc Dubresson, Applicant/Owner
They have not found a design that would match their Normandy style. They prefer to
get a recommendation instead of a continuance.
Closed Public Comment.
MOTION: Motion by Chair Quintana to forward a recommendation of denial of the
above request to the Community Development Director. Cannot make
the consideration that it will not adversely affect the exterior
architectural characteristics or other features of the property. Seconded
by Commissioner Burnett.
VOTE: Motion passed 2-1 with Vice Chair Queiroz dissenting.
OTHER BUSINESS (Up to three minutes may be allotted to each speaker on any of the following
items.)
6. Consider a Request for Preliminary Review to Construct a New Second-Story Addition
and Exterior Alterations to an Existing Pre-1941 Single-Family Residence on Property
Zoned R-1D. Located at 245 Los Gatos Boulevard. APN 529-24-024. Request for Review
Application PHST-25-011. Exempt Pursuant to CEQA Guidelines, Section 15301: Existing
Facilities. Property Owner: Michael Phung. Applicant: Andres Johnson. Project Planner:
Samina Merchant.
Samina Merchant, Project Planner, presented the staff report
Opened public comment.
Andres Johnson, Applicant; Michael Phung and Monique Pham, Owner
Proposing a second story in the back. They are going with a Spanish style. The goal and
intent are to incorporate elements that enhance that style such as brackets and recessed
arches. The owners love the neighborhood, schools and historic area. They were not sure of the
house’s style. They went with Spanish because that’s what they thought it was. They are open
to the Committee’s suggestions. They want it to look like it belongs on the street. They intend
to have one primary bedroom downstairs for their older parents.
Committee members asked questions of the applicant.
Andres Johnson, Applicant; Michael Phung and Monique Pham, Owner
They were trying to follow the Design Guidelines and thought it should not be on the
historical front part of the house.
Page 13
PAGE 10 OF 11 MINUTES OF THE HISTORIC PRESERVATION COMMITTEE MEETING OF JUNE 25, 2025
Closed public comment.
Committee asked questions of Staff.
Sean Mullin, Planning Manager
There is nothing in the Town Code that prohibits an addition being made in the front but
can understand why they thought that.
Chair Quintana
In practice, we’d like to see addition set back, but not all the way back. This would
better integrate with the existing house.
Commissioner Burnett
The design is very nice.
Chair Quintana
Open to a redesign that brings the addition forward. It works with a one-story house.
Would like to see it embellished with more Spanish style in front of the house.
7. Consider Potential Communications from the Historic Preservation Committee to the
Town Council Regarding a Work Plan.
Sean Mullin, Planning Manager, presented the staff report
Members can individually contact the Council. As an alternative, staff recommends that
a member of the Committee compose a letter. The letter can then be agendized, discussed,
approved, and presented to the Council.
Committee members discussed the matter.
Sean Mullin, Planning Manager
Create a simple framework and have the other members bring their ideas to the
meeting. Do not discuss outside a meeting because of the Brown Act. There should be no blind
copying or emails. Only two people should work on it outside the meeting. Have other
members individually think of what they want to add and bring them agendized public hearing
meeting. Having a special meeting to discuss the letter is a good idea.
REPORT FROM THE DIRECTOR OF COMMUNITY DEVELOPMENT
Sean Mullin, Planning Manager
The recommendations of the Committee have been reflected in the CDD Directors
decisions. The denial of removal for Loma Street has been appealed. It will come before the
Planning Commission in August.
Page 14
PAGE 11 OF 11 MINUTES OF THE HISTORIC PRESERVATION COMMITTEE MEETING OF JUNE 25, 2025
Committee members asked questions of staff.
Sean Mullin, Planning Manager
Some items can take years to resolve and track, instead, staff can report on any
appealed decisions or significant happenings.
COMMITTEE MATTERS
None.
ADJOURNMENT
The meeting adjourned at 5:49 p.m.
This is to certify that the foregoing is a true
and correct copy of the minutes of the
June 25, 2025 meeting as approved by the
Historic Preservation Committee.
Sean Mullin, AICP, Planning Manager
Page 15
This Page
Intentionally
Left Blank
Page 16
PREPARED BY: Samina Merchant
Associate Planner
110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874
www.losgatosca.gov
TOWN OF LOS GATOS
HISTORIC PRESERVATION COMMITTEE
REPORT
MEETING DATE: 08/27/2025
ITEM NO: 2
DATE: August 22, 2025
TO: Historic Preservation Committee
FROM: Joel Paulson, Community Development Director
SUBJECT: Consider a Request for Approval to Construct Exterior Alterations to an
Existing Contributing Single-Family Residence in the Broadway Historic
District on Property Zoned R-1D:LHP. Located at 68 Broadway. APN 510-45-
085. Request for Review HS-25-035. Exempt Pursuant to CEQA Guidelines,
Section 15301: Existing Facilities. Property Owner/Applicant: Marc
Dubresson. Project Planner: Samina Merchant.
RECOMMENDATION:
Consider a request for approval to construct exterior alterations to an existing contributing
single-family residence in the Broadway Historic District on property zoned R-1D:LHP, located at
68 Broadway.
PROPERTY DETAILS:
1. Date primary structure was built: 1935 per County Assessor; 1920s per Anne Bloomfield
Survey
2. Bloomfield Preliminary Rating: “+” Historic and intact or worthy of special note
3. Does property have an LHP Overlay? Yes
4. Is structure in a historic district? Yes, Broadway Historic District
5. If yes, is it a contributor? Yes
6. Findings required? No
7. Considerations required? Yes
BACKGROUND:
The Santa Clara County Assessor’s Database lists a construction date of 1935 for the existing
residence. The 1990 Anne Bloomfield Survey describes the residence as being built in the
‘Hansel & Gretel’ style with an estimated construction date of the 1920s (Attachment 1). The
Bloomfield Survey rates the residence as historic and intact or worthy of special note. The
Sanborn Fire Insurance Maps show that the footprint of the residence remained consistent
Page 17
PAGE 2 OF 3
SUBJECT: 68 Broadway/ HS-25-035
DATE: August 22, 2025
between 1928 and 1956 (Attachment 2). The applicant submitted documents based on their
findings from the research worksheet, which are included in Attachments 3 and 4.
The following is a summary of the Town Records in Attachment 5:
1. 1984: M-84-22 – Subdivision and Lot Line Adjustment resulting in four separate lots seen
today as 72 and 68 Broadway and 305 and 307 W Main Street;
2. 1988: S-88-22 – Living area expansion on right side;
3. 1989 – Earthquake damage repairs included remodeling the home with a larger kitchen,
master suite, traditional staircase, reuse of fallen brick for patio and walkways, a new pool,
and cellar;
4. 1992 - HPC approval to construct a carport; and
5. 2011: HS-11-035 - HPC approved renovations to the front elevation to remove an existing
door and replace it with a window to match the existing.
On June 25, 2025, the Committee was unable to make the required considerations pursuant to
Section 29.80.290 of the Town Code and recommended denial of the request to construct
exterior alterations to an existing contributing single-family residence in the Broadway Historic
District to the Community Development Director. The request was denied by the Community
Development Director on June 26, 2025.
DISCUSSION:
On June 25, 2025, the Committee reviewed a request to construct exterior alterations,
including replacing the existing aluminum sliding door on the rear elevation with a new 16-foot-
wide folding door system. The Committee opined that the proposed door’s style and scale
differed from the style of the existing windows, and that the proposed work would adversely
affect the exterior architectural characteristics or other features of the property. The
Committee recommended exploring custom door manufacturers that offer options with divided
lites to give the door proportionality and compatibility with the existing facade while still
providing the open light panel view. A denial of the proposal, as submitted, was recommended.
The applicant subsequently submitted revised project plans and a justification letter with the
same general scope, requesting to remodel a portion of the first-floor area within the existing
building footprint, but featuring a different rear door in response to the Committee’s
recommendations (Attachments 3 and 7). The updated proposal includes replacing the existing
aluminum sliding door on the rear elevation with a new 16-foot-wide folding door system from
Bend River Sash and Door Company (Attachment 8, Sheet D.2). The proposed wood door
features divided lites and would be painted to match the existing doors and windows to remain
and the existing trellis at the rear patio. On the northwest (left side) elevation, two existing
windows would be removed and replaced with one new wood window to match the existing
windows in style and color (Attachment 8, Sheet D.1). All trims would match the original style,
and the existing stucco siding and horizontal brick veneer would remain in place.
Page 18
PAGE 3 OF 3
SUBJECT: 68 Broadway/ HS-25-035
DATE: August 22, 2025
CONCLUSION:
The applicant is requesting approval to construct exterior alterations to an existing contributing
single-family residence in the Broadway Historic District on property zoned R-1D:LHP. Should
the Committee find merit in the request, a recommendation of approval would be forwarded to
the Community Development Director. The application would continue through the Building
Permit process and would not return to the Committee.
CONSIDERATIONS:
A. Considerations.
Sec. 29.80.290. Standards for review.
In evaluating applications, the deciding body shall consider the architectural style, design,
arrangement, texture, materials and color, and any other pertinent factors. Applications
shall not be granted unless:
__X__ In historic districts, the proposed work will neither adversely affect the exterior
architectural characteristics or other features of the property which is the subject of
the application, nor adversely affect its relationship, in terms of harmony and
appropriateness, with its surroundings, including neighboring structures, nor
adversely affect the character, or the historical, architectural or aesthetic interest or
value of the district.
B. Residential Design Guidelines.
Sections 4.8.3 and 4.8.4 of the Town’s Residential Design Guidelines offer recommendations
relative to windows and doors located in Historic Districts and/or on historic properties
(Attachment 7).
ATTACHMENTS:
1. 1990 Anne Bloomfield Survey
2. Sanborn Fire Maps
3. Justification Letter
4. Applicant’s Research
5. Town Planning & Building Records
6. Existing Exterior Elevation Photo
7. Section 4.8.3 & 4.8.4, Residential Design Guidelines
8. Proposed Plans
Page 19
This Page
Intentionally
Left Blank
Page 20
ATTACHMENT 1Page 21
This Page
Intentionally
Left Blank
Page 22
1908ATTACHMENT 2Page 23
1928Page 24
1928-1944Page 25
1956Page 26
Re: Resubmittal – Rear Window/Door Modification at 68 Broadway
Dear Chair, members of the Historic Preservation Committee and members of the staff,
Thank you for your time and thoughtful review of our initial application regarding modifications to the rear façade of our home. We greatly appreciate the committee’s input and have taken your feedback seriously in preparing this resubmittal.
In response to the committee’s comments, we are now fully committed to ensuring that all proposed windows and folding doors include divided lites to match the existing historic style of the home. We understand that consistency in design is essential to maintaining the architectural integrity of the property and the neighborhood.
At your suggestion, we reached out to Bend River, a company with experience in the Los Gatos historic district. They confirmed their ability to custom-manufacture folding doors with divided lites, matching both the color and detailing of our existing windows. This option had not surfaced in our earlier research, and we now agree that it offers the best blend of functional improvement and historic compatibility.
We continue to believe this modest change to the rear of the house—entirely out of public view—will enhance the livability of our kitchen while remaining faithful to the property’s historical character. We hope this revised submission reflects our alignment with the town’s preservation values.
Thank you again for your consideration.
Sincerely,
Marc Dubresson
ATTACHMENT 3
Page 27
This Page
Intentionally
Left Blank
Page 28
ATTACHMENT 4
Page 29
Page 30
Page 31
Page 32
Page 33
Page 34
Page 35
Page 36
Page 37
This Page
Intentionally
Left Blank
Page 38
ATTACHMENT 5Page 39
Page 40
Page 41
Page 42
Page 43
Page 44
Page 45
Page 46
Page 47
Page 48
Page 49
Page 50
Page 51
Page 52
Page 53
Page 54
Page 55
Page 56
Page 57
Page 58
Page 59
Page 60
Page 61
Page 62
Page 63
Page 64
Page 65
This Page
Intentionally
Left Blank
Page 66
Source: Redfin. (n.d.). Photo of residential property located at 68 Broadway, Los Gatos, CA [Image]. Redfin. Retrieved June 11, 2025, from https://www.redfin.com/ATTACHMENT 6Page 67
This Page
Intentionally
Left Blank
Page 68
Residential Design Guidelines48
Town of Los Gatos
HISTORIC RESOURCES4
•New materials should identically match original materials
in shape, size, dimension, texture and pattern. Metal used
as flashing, screening, gutters, and utility services and other
traditional elements are acceptable.
•Composite, synthetic, metal, vinyl, plastic or fabricated/
imitation wood products, painted brick or imitation used
brick will generally not be approved. However, some ex-
ceptions may be made on a case-by-case basis when the
decision making body determines that the replacement is
consistent with the appearance of the original material, and
that a lay person would be unlikely to discern the difference.
The burden of proof will reside with the applicant. Mate-
rial samples, photographs and specific locations where the
material may be seen in use will all assist in the evaluation
of alternative materials.
•The decision making body may approve an acceptable alter-
native to the original building material if use of the original
material is not feasible due to unreasonable cost and com-
mercial availability, or health and safety considerations.
4.8.3 Doors
•Original doors should be retained and restored.
•New replacement doors for Victorians should not be flush,
but of raised or flat panel design.
•Front doors generally should be painted, not stained.
Not applicable to Mission Revival/Mediterranean style structures.
•Screened doors should be real wood framed of simple de-
sign unless patterns can be shown to fit the existing style.
4.8.4 Windows and Glass in doors
•Original windows, glass and window decorations should be
retained and restored.
•Replacement of only the deteriorated portions of the win-
dows is recommended rather than the replacement of the
entire window.
•New or replacement windows should be wood-sashed and
muntined if applicable.
•Sills, lintels, frames, sashes, muntins, and all decorations
should be identically replaced.
•All elements of new windows should be identical in size,
shape, proportion, and dimensions as the original windows
of the building, or consistent with traditional sizes, propor-
tions and dimensions of buildings of the same architectural
style, design and era.
•Windows should be constructed of real glass, and window
Simulated divided lite windows may be considered on a case-by-case basis
True divided lite windows are encouraged when appropriate to the original structure
Original doors and windows should be
retained and repaired
ATTACHMENT 7
Page 69
Residential Design Guidelines 49
Town of Los Gatos HISTORIC RESOURCES4
frames should be constructed of real wood - not vinyl,
metal or plastic. Wood sashes may be vinyl or metal clad if
the window frame and dressing is designed consistent with
the historic context of the building.
• All lites (panes of glass) should be true divided lite, not
artificial or snap-in grids. Simulated Divided Lite windows
are permitted when the details of the window provide
projecting muntin elements on the exterior and interior of
the window along with a spacer muntin between the panes
of glass (See example to the left).
• New arched, angled, and/or octagonal windows are discour-
aged.
• Large expanses of blank exterior walls without windows
are discouraged.
4.8.5 Bay Windows
• Size, shape, proportion, dimension, type of foundation, and,
roof material and style of bay windows, whether restored
or of new construction, should be identical to the original
or existing bay windows of the structure.
• New bay windows may be added to the building in loca-
tions where no bay windows previously existed. These new
bay windows should be identical to and replicate the style,
design, size, shape and proportion, type of foundation and
roof of other bay windows existing on structure. If there are
no existing bay windows on the structure, new bay windows
should be built in the same size, shape, dimension, propor-
tions, material and type of foundation and roof typical of
the architectural style. Metal frame kitchen garden windows
are prohibited.
• Generally, traditional architectural styles will require either a
foundation to the ground or substantial supporting brackets
below a bay window. Floating windows without support, as
shown for the bow bay window example to the right, are
rarely appropriate.
• New bay windows are permitted only when the applicant
proves to the Deciding Body that they are consistent with
existing style, design and character of the structure.
4.8.6 Chimneys
• Wood-framed chimneys are prohibited unless their exteri-
ors are covered with brick or river rock veneers. Masonry
veneers may be used. However, they should be detailed
exactly as the solid construction that they are emulating.
• Stucco Mission Revival or Mediterranean style houses may
have stucco covered chimneys.
Match bay windows to the architectural style
of the house
Some window styles, such as this bow bay window, would have very limited applicability for use on a historic resource structure
Wood clad chimneys are prohibited
Masonry and stucco chimneys are
preferred
Page 70
ATTACHMENT 8Page 71
Page 72
Page 73
Page 74
Page 75
Page 76
Page 77
This Page
Intentionally
Left Blank
Page 78
PREPARED BY: Maria Chavarin
Assistant Planner
TOWN OF LOS GATOS
HISTORIC PRESERVATION
COMMITTEE REPORT
MEETING DATE: 08/27/2025
ITEM NO: 3
DATE: August 22, 2025
TO: Historic Preservation Committee
FROM: Joel Paulson, Community Development Director
SUBJECT: Consider a Request for Approval to Construct Exterior Alterations (Window
Replacement) to an Existing Pre-1941 Single-Family Residence on Property
Zoned R-1:8. Located at 16760 Magneson Loop. APN 523-06-015. Request for
Review Application PHST-25-014. Exempt Pursuant to CEQA Guidelines,
Section 15301: Existing Facilities. Property Owner/Applicant: Mickael
Forsman. Project Planner: Maria Chavarin.
RECOMMENDATION:
Consider a request for approval to construct exterior alterations (window replacement) to an
existing pre-1941 single-family residence on property zoned R-1:8, located at 16760 Magneson
Loop.
PROPERTY DETAILS:
1. Date primary structure was built: 1932 per County Assessor; 1930’s per Bloomfield Survey
2. Bloomfield Preliminary Rating: “+” Historic and intact or worthy of special note
3. Does property have an LHP Overlay? No
4. Is structure in a historic district? N/A
5. If yes, is it a contributor? N/A
6. Findings required? No
7. Considerations required? Yes
BACKGROUND:
The subject property is located on the south side of Magneson Loop, just east of Los Gatos Blvd.
The County Assessor indicates a construction date of 1932. The Bloomfield Survey estimates
the construction date as the 1930s, providing a preliminary rating of Historic and intact or
worthy of special note (Attachment 1).
Page 79
PAGE 2 OF 4
SUBJECT: 16760 Magneson Loop/PHST-25-014
DATE: August 22, 2025
DISCUSSION:
The applicant submitted a Letter of Justification (Attachment 2) requesting approval to replace
14 existing windows. The photos and plans (Attachments 3 and 5) provided by the applicant
indicate that 14 windows will be replaced. The majority of the existing wood windows would be
replaced with Fibrex-wood composite windows with the exception of windows numbered 114
through 116, which would be aluminum-clad wood windows. Some of the window types are
proposed to change. Below is a summary of the changes to the window types (Attachment 4)
and materials.
Window
Number
Existing Window
Type
Proposed Window
Type
Existing
Material
Proposed Material
103 Picture w/
divided lites
Picture w/out divided
lites
Wood Fibrex-wood
composite
104 Picture
w/divided lites
Picture w/out divided
lites
Wood Fibrex-wood
composite
105 Picture w/
divided lites
Picture w/out divided
lites
Wood Fibrex-wood
composite
106 Picture/ w
divided lites
Picture w/out divided
lites
Wood Fibrex-wood
composite
107 Picture
w/divided lites
Picture w/out divided
lites
Wood Fibrex-wood
composite
108 Picture
w/divided lites
Picture w/out divided
lites
Wood Fibrex-wood
composite
109 Single Casement
w/divided lites
Single Casement
w/out divided lites
Wood Fibrex-wood
composite
110 Single Casement
w/divided lites
Single Casement
w/out divided lites
Wood Fibrex-wood
composite
111 Single Casement
w/divided lites
Single Casement
w/out divided lites
Wood Fibrex-wood
composite
113 Single Casement
w/divided lites
Single Casement
w/out divided lites
Wood Fibrex-wood
composite
112 Picture
w/divided lites
Picture w/out divided
lites
Wood Fibrex-wood
composite
114 Double Hung
w/divided lites
Single Casement
w/divided lites
Wood Aluminum-clad
wood
115 Double Hung
w/divided lites
Single Casement
w/divided lites
Wood Aluminum-clad
wood
116 Double Hung
w/divided lites
Single Casement
w/divided lites
Wood Aluminum-clad
wood
Page 80
PAGE 3 OF 4
SUBJECT: 16760 Magneson Loop/PHST-25-014
DATE: August 22, 2025
The Residential Design Guidelines provides the following recommendations related to window
materials:
3.7.2 Match window types and proportions to the architectural style and to the
surrounding neighborhood
• Select window types to complement the style of the house. Each architectural style
generally has one or two window types that are traditional to the style. Double hung
windows, for example, are common features of Victorian and Craftsman Styles while
casement windows are seen frequently in Mission and Spanish Eclectic styles
3.7.3 Match window materials to the architectural style and to the surrounding
neighborhood
• Wood windows are common in Los Gatos. Wood is still the desired choice for styles that
traditionally used wood. However, today there are some window materials, such as vinyl
clad wood windows that are not noticeably different from wood at a short distance.
3.7.4 Design the windows with attention to matching the traditional details of the
architectural style
• Divided lights (i.e., larger window panes broken up into smaller pieces) are common in
many home styles found in Los Gatos. Use either vertical or square proportions for the
smaller window elements. Be consistent in the proportions (i.e., the ratio of the
horizontal to the vertical dimension) of the smaller panes. Do not use snap in flat grids
to simulate divided lights. Use either true divided lights or one of the newer window
systems that have dimensional muntins on both the exterior and interior of the glass
along with a spacer muntin between the panes of glass. Use consistently for windows on
all sides of the house.
4.8.2 Building Materials
• Composite, synthetic, metal, vinyl, plastic or fabricated/ imitation wood products,
painted brick or imitation used brick will generally not be approved. However, some ex-
ceptions may be made on a case-by-case basis when the decision-making body
determines that the replacement is consistent with the appearance of the original
material, and that a lay person would be unlikely to discern the difference. The burden
of proof will reside with the applicant. Material samples, photographs, and specific
locations where the material may be seen in use will all assist in the evaluation of
alternative materials.
Page 81
PAGE 4 OF 4
SUBJECT: 16760 Magneson Loop/PHST-25-014
DATE: August 22, 2025
4.8.4 Windows and Glass in doors
• Windows should be constructed of real glass, and window frames should be constructed
of real wood - not vinyl, metal, or plastic. Wood sashes may be vinyl or metal clad if the
window frame and dressing is designed consistent with the historic context of the
building.
The proposed Fibrex-wood composite material was not available when the Guidelines were
written, and it is silent on its use. The Guidelines emphasize the use of wood windows but allow
exceptions for alternative materials when they are not noticeably different from wood at a
short distance, found to be consistent with the historic context, and consistent with the
appearance of the original material where it would be unlikely to discern the difference.
CONSIDERATIONS:
A. Considerations
Sec. 29.80.290. Standards for review.
In evaluating applications, the deciding body shall consider the architectural style, design,
arrangement, texture, materials and color, and any other pertinent factors. Applications
shall not be granted unless:
__X__ For pre-1941 structures, the proposed work will neither adversely affect the exterior
architectural characteristics or other features of the property which is the subject of
the application.
CONCLUSION:
The applicant requests approval to replace 14 existing wood windows in varying styles, 11 of
which would be with Fibrex-wood composite windows and three would be aluminum-clad
wood windows (Attachments 2 and 5). Should the Committee find merit in the request, a
recommendation of approval would be forwarded to the Community Development Director,
and the project would be completed with a Building Permit. The project would not return to the
Committee.
Page 82
PAGE 5 OF 4
SUBJECT: 16760 Magneson Loop/PHST-25-014
DATE: August 22, 2025
ATTACHMENTS:
1. 1990 Anne Bloomfield Survey
2. Letter of Justification
3. Existing Photos
4. Proposed Window Specifications
5. Proposed Floor Plan
Page 83
This Page
Intentionally
Left Blank
Page 84
;1//t,.
dfnne. !B{oom{ie.fd
ARCHITECTURAL/CULTURAL SURVEY
LOS GATOS RESEARCH
File address /~ 7~{.) /11~~, f.ot:J{?
PARCEL MAP INFORMATION
ARCHITECTURAL HISTORY
(41 5> 922·1 063
2229 WEBSTER STREET
SAN FRANCISCO. CA 941 1 5
Parcel # 5~~ .... 010"".015'
Lot shape: Rectangle_£' L_
Lot size: 5 0 front ft. x /t; S ft. deep
Rectangle with small rear jog ___ Other ______________________ __
Location: N S / E \v side of ~ St Ave Other J.o a p
distance to cross st: /1b ft . N_ S_ E /w_ from )._, ~ ~/.
at NE NW SE SW corner of -------------------------
HISTORIC INFORMATION ON PARCEL MAP / /' Jt4( b t-o-1 &' {:::9t:J.
Old tract or subdivision name C,c-.. ,~t?v 1 Old Block # Old lot # / p /n I
FIELD SURVEY INFORMATION (handwritten in red)
Preliminary rating + Estimated age /1~0./ Style--p01/; 1\ c_..iA-/ # stories__
Alterations•-------------------------------------------------------------------------------------
Other--------------------------------------------------====================~====~~=;~
COUNTY ASSESSOR--PROPERTY CHARACTERISTICS (paste on copy) Pageq J!i EFFective date 1-:;J. -"87
OWNERSHIP SHOWN ON MAPS
Source
Name
----
Source
Date
:1891
Blk Book 1908
Survey i1941 ,--
Source
Page
Location of property, oriLot
Old ·tract/block/lot Size
Owner
Name
MISCELLANEOUS PHOTOS: Roll/frame #/~3~ ; National Register listed date __________________ ___
County Inventory 1979--------------~------------Town of Los Gatos: Designation ____ Recognition __ _
District Name ·----------------------------------
Previous Survey
Gebhard : page # _____ illustration page # ______ __
Butler/Junior League
v.:;A-B
Dat ~/~-?'D
ATTACHMENT 1Page 85
This Page
Intentionally
Left Blank
Page 86
Shiloh Witcosky
Senior Design Consultant - Renewal by Andersen
On behalf of the homeowner:
Mickael Forsman
16760 Magneson Loop
Los Gatos, CA
Date: August 4, 2025
Town of Los Gatos Planning Department
110 E. Main Street
Los Gatos, CA 95030
RE: Request for Window Replacement Without
Grilles – Justification Letter for 16760 Magneson
Loop
To Whom It May Concern,
I am writing on behalf of the homeowner at the above
property to respectfully request approval for the
replacement of the home’s windows using Andersen
Acclaim composite units without grilles. These windows
have a true wood-like appearance, a flat finish, and
mortise-style joints to maintain historical integrity while
improving energy efficiency and longevity. This proposal
ATTACHMENT 2
Page 87
seeks to remove the existing grilles, which were likely not
part of the home’s original design.
Architectural Background
This home is located within a small cluster of storybook-
style homes constructed between the 1920s and late
1930s, making them eligible under Los Gatos’s “built
before 1941” criteria. These whimsical, European-inspired
homes feature dramatic rooflines, asymmetrical façades,
and charming handcrafted details. The window designs
used in this style historically varied—many were large,
clear-paned, and intentionally lacked divided lights to
balance the visual complexity of the home’s silhouette and
textured materials.
While it is true that many whimsical Tudor and storybook
homes from this era featured ornate leaded glass or
divided lights, it is also important to note that the windows
being replaced on this property are not original. The one
window on the front façade that is both architecturally
significant and features intricate leaded glass will be
retained. This element is one of the few remaining
examples of such craftsmanship on the street and helps
preserve the historic character of the home.
16760 Magneson Loop
(replacement in question - leaded glass
remains)
Page 88
Neighborhood Precedent
A walk-through visual survey of Magneson Loop confirms
the presence of multiple nearby homes that feature grille-
free window replacements. Most notably:
-Directly next door, the adjacent home features modern
replacement windows without grilles. (16750 Magneson
Loop)
- Directly across the street, another home of similar
style and age also features clear-pane windows without
grid patterns. (16771 Magneson Loop)
These examples establish a clear and recent precedent
for gridless windows within this immediate architectural
cluster. Both homes preserve the character and charm of
Page 89
the neighborhood while opting for simpler, historically
appropriate glazing patterns.
16750 Magneson Loop - Nextdoor
Neighbor has replaced with completely clear glass.
16750 Magneson Loop - Close Up Next Door
160760 Magneson Loop - Directly Across the Street
Page 90
160760 Magneson Loop - Directly Across the Street
These wood pocket, wood core frames seem to
be very likely original
Preservation of Style and Intent
Although the current windows on the subject property do
contain grilles, these are later additions, inconsistent with
some of the original construction trends. The homeowner’s
choice to return to clean, grille-free windows—while
retaining the original leaded-glass front window—reflects a
sensitive and historically aligned approach to restoration.
Page 91
The proposed Andersen Acclaim units deliver exceptional
visual fidelity to wood while meeting today’s performance
standards. This ensures material and aesthetic
compatibility with the historic nature of the home and
surrounding area.
Summary Checklist of Justification Points
- ✅ Architectural style (storybook/whimsical) often
featured leaded glass or clear-paned windows
- ✅ Windows being replaced are not original; front façade
leaded glass window will remain
- ✅ Historical reference supports gridless windows in
homes of this vintage (1920s–30s) (living Places)
- ✅ Two neighboring homes—one next door and one
across the street—have recently installed gridless window
replacements
- ✅ Proposed windows maintain appropriate material
appearance and visual quality
We respectfully request that the Planning Department to
consider and approve this proposal based on the
neighborhood context, architectural accuracy, and the
clear visual precedent set by immediate neighbors. Thank
you for your time and thoughtful consideration.
Sincerely,
Shiloh Witcosky
On behalf of Mickael Forsman
Page 92
Switcosky@renewalbayarea.com
(408) 564-9341
Page 93
To the Esteemed Members of the Los Gatos Historical Preservation Committee,
Subject: Request for Approval to Modify Window Grids at 16760 Magneson Loop, Los
Gatos
I am writing to respectfully request your committee's consideration and approval for a
proposed modification to certain windows at my residence located at 16760
Magneson Loop in Los Gatos. As you are aware, my home, a beautiful white Tudor-
style house built in the 1930s, is recognized as a historically significant property within
our cherished community. I deeply value and am committed to preserving the unique
character and historical integrity that defines my home and contributes to the rich
heritage of Los Gatos.
My proposal involves the removal of the decorative grids from a select few windows on
the property. Specifically, I am seeking to remove the grids from one large window in
the living room, which directly faces the street, and five windows on the side of the
house that are partially visible from the street.
The primary motivation for this request stems from a desire to enhance the aesthetic
clarity and natural light within these specific interior spaces, while simultaneously
refining the exterior presentation of these particular windows. Upon careful
consideration of the house's original architectural intent and the evolution of its
design over time, I believe that the grids on these specific windows, particularly the
large living room window, introduce a visual busyness that detracts from the elegant
simplicity and expansive views that the Tudor style can also embody. Removing them
will allow for a more unobstructed connection with the surrounding landscape,
bringing more natural light into the living areas and creating a more harmonious visual
flow from both inside and out.
It is crucial to emphasize that this request is highly selective and thoughtfully
considered. I am fully committed to retaining the distinctive historical elements of my
home. To that end, I will be preserving the most historically styled window, featuring
its original leaded grids, which also faces directly onto the street. This iconic window
will continue to serve as a prominent historical feature, ensuring that the
quintessential Tudor character of the facade remains intact and celebrated. My aim is
not to diminish the historical value of the property, but rather to subtly refine certain
aspects in a manner that I believe will enhance its overall beauty and livability, while
still honoring its architectural heritage.
I understand and respect the vital role the Historical Preservation Committee plays in
safeguarding Los Gatos's unique architectural legacy. I am confident that these
Page 94
proposed changes, by focusing on specific windows and deliberately preserving the
most significant historical elements, will contribute positively to the property's
appearance without compromising its historical designation.
I am available to provide any further information, architectural drawings, or to meet
with the committee at your earliest convenience to discuss this request in more
detail. Thank you for your time and consideration of this important matter.
Sincerely,
Mickael Forsman
mickaelforsman@gmail.com
Mobile +1-650-380-7064
16760 Magneson Loop Los Gatos, CA (USA)
Page 95
This Page
Intentionally
Left Blank
Page 96
Page 97
Page 98
Line 109
Line 110
Line 111, 112, 113
Page 99
Line 114, 115, 116
Page 100
Page 101
Order Summary
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
ID# ROOM SIZE DETAILS
JOB
Misc: Misc, All Job Charges Miscellaneous charges, Production OHLJ
Adjustment Fee, Quantity 1, Haul Away, Dispose, City, County, State, Home
Owner Association Regulatory and Compliance Fees (as applicable).
Construction: None Material: None
0" 0"
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine
Performance Calculator: PG Rating: 50 | DP Rating: + 50 / - 50 Glass: All
Sash: High Performance SmartSun with HeatLock Glass, No Pattern,
Tempered Glass Grille Style: No Grille Misc: None Construction: Precision
cut back interior stops (1) Material: Flashing Tape 4" (0.25), Foam Can
(0.15), White Caulk (Insert) (3), White L-Trim 12ft (2), White Retro-L Coil
10ft (2)
106 Living Room 24"
23-1/2"
71"
77"
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine
Performance Calculator: PG Rating: 50 | DP Rating: + 50 / - 50 Glass: All
Sash: High Performance SmartSun with HeatLock Glass, No Pattern,
Tempered Glass Grille Style: No Grille Misc: None Construction: Precision
cut back interior stops (1) Material: Flashing Tape 4" (0.25), Foam Can
(0.15), White Caulk (Insert) (3), White L-Trim 12ft (2), White Retro-L Coil
10ft (2)
107 Living Room 24"
23-1/2"
71"
77"
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine
Performance Calculator: PG Rating: 50 | DP Rating: + 50 / - 50 Glass: All
Sash: High Performance SmartSun with HeatLock Glass, No Pattern,
Tempered Glass Grille Style: No Grille Misc: None Construction: Precision
cut back interior stops (1) Material: Flashing Tape 4" (0.25), Foam Can
(0.15), White Caulk (Insert) (3), White L-Trim 12ft (2), White Retro-L Coil
10ft (2)
108 Living Room 24"
23-1/2"
71"
77"
06/06/25 Page 2 / 40
Page 102
Order Summary
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
ID# ROOM SIZE DETAILS
Window: Acclaim™ Casement Single, Left, Base Frame, Exterior White,
Interior Pine Performance Calculator: PG Rating: 40 | DP Rating: + 40 / -
40 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No
Pattern Hardware: White Screen: Fiberglass, Full Screen Grille Style: No
Grille Misc: None Construction: Precision cut back interior stops (1)
Material: Flashing Tape 4" (0.25), Foam Can (0.15), White Caulk (Insert)
(3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
109 Living Room 24"
23-1/2"
61"
60"
Window: Acclaim™ Casement Single, Right, Base Frame, Exterior White,
Interior Pine Performance Calculator: PG Rating: 40 | DP Rating: + 40 / -
40 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No
Pattern Hardware: White Screen: Fiberglass, Full Screen Grille Style: No
Grille Misc: None Construction: Precision cut back interior stops (1)
Material: Flashing Tape 4" (0.25), Foam Can (0.15), White Caulk (Insert)
(3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
110 Living Room 24"
23-1/2"
61"
60"
Window: Acclaim™ Casement Single, Left, Base Frame, Exterior White,
Interior Pine Performance Calculator: PG Rating: 40 | DP Rating: + 40 / -
40 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No
Pattern Hardware: White Screen: Fiberglass, Full Screen Grille Style: No
Grille Misc: None Construction: Precision cut back interior stops (1)
Material: Flashing Tape 4" (0.25), Foam Can (0.15), White Caulk (Insert)
(3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
111 Dining 24"
23-1/2"
61"
59-3/4"
Window: Acclaim™ Casement Fixed Window, Base Frame, Exterior White,
Interior Pine Performance Calculator: PG Rating: 40 | DP Rating: + 40 / -
40 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No
Pattern Grille Style: No Grille Misc: None Construction: Precision cut back
interior stops (1) Material: Flashing Tape 4" (0.25), Foam Can (0.15),
White Caulk (Insert) (3), White L-Trim 12ft
112 Dining 24"
24"
61"
59-3/4"
06/06/25 Page 3 / 40
Page 103
Order Summary
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
ID# ROOM SIZE DETAILS
(2), White Retro-L Coil 10ft (2)
Window: Acclaim™ Casement Single, Right, Base Frame, Exterior White,
Interior Pine Performance Calculator: PG Rating: 40 | DP Rating: + 40 / -
40 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No
Pattern Hardware: White Screen: Fiberglass, Full Screen Grille Style: No
Grille Misc: None Construction: Precision cut back interior stops (1)
Material: Flashing Tape 4" (0.25), Foam Can (0.15), White Caulk (Insert)
(3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
113 Dining 24"
23-1/2"
61"
59-3/4"
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine
Performance Calculator: PG Rating: 50 | DP Rating: + 50 / - 50 Glass: All
Sash: High Performance SmartSun with HeatLock Glass, No Pattern Grille
Style: No Grille Misc: None Construction: Precision cut back interior stops
(1) Material: Flashing Tape 4" (0.25), Foam Can (0.15), White Caulk
(Insert) (2), White L-Trim 12ft (1), White Retro-L Coil 10ft (1)
103 Living Room 24"
23-1/2"
24"
23"
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine
Performance Calculator: PG Rating: 50 | DP Rating: + 50 / - 50 Glass: All
Sash: High Performance SmartSun with HeatLock Glass, No Pattern Grille
Style: No Grille Misc: None Construction: Precision cut back interior stops
(1) Material: Flashing Tape 4" (0.25), Foam Can (0.15), White Caulk
(Insert) (2), White L-Trim 12ft (1), White Retro-L Coil 10ft (1)
104 Living Room 24"
23-1/2"
24"
23"
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine
Performance Calculator: PG Rating: 50 | DP Rating: + 50 / - 50 Glass: All
Sash: High Performance SmartSun with HeatLock Glass, No Pattern Grille
Style: No Grille Misc: None Construction: Precision cut back interior stops
(1) Material: Flashing Tape 4" (0.25), Foam Can (0.15), White Caulk
(Insert) (2), White L-Trim 12ft (1), White Retro-L Coil 10ft (1)
105 Living Room 24"
23-1/2"
24"
23"
06/06/25 Page 4 / 40
Page 104
Order Summary
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
ID# ROOM SIZE DETAILS
Window: Acclaim™ Casement Single, Right, Base Frame, Exterior Dark
Bronze, Interior White Performance Calculator: PG Rating: 40 | DP Rating:
+ 40 / - 40 Glass: All Sash: High Performance SmartSun with HeatLock
Glass, No Pattern Hardware: White, Wide Opening Hinge Screen:
Fiberglass, Full Screen Grille Style: Full Divided Light (FDL with spacer),
Permanently Applied Interior Wood Grille Grille Pattern: All Sash: Colonial
1w x 3h Misc: E-Series Window, Product Requirement for Permit/HOA
Construction: None Material: Flashing Tape 4" (0.25), Foam Can (0.15),
White Caulk (Insert) (1), Dark Bronze L-trim (12ft) (2), Dark Bronze Retro-L
Coil - 10ft (2), Dark Bronze Caulk (Insert) (4)
114 Second
Bedroom
35"
35-1/2"
55"
52-3/4"
Window: Acclaim™ Casement Single, Left, Base Frame, Exterior Dark
Bronze, Interior White Performance Calculator: PG Rating: 40 | DP Rating:
+ 40 / - 40 Glass: All Sash: High Performance SmartSun with HeatLock
Glass, No Pattern Hardware: White, Wide Opening Hinge Screen:
Fiberglass, Full Screen Grille Style: Full Divided Light (FDL with spacer),
Permanently Applied Interior Wood Grille Grille Pattern: All Sash: Colonial
1w x 3h Misc: E-Series Window, Product Requirement for Permit/HOA
Construction: None Material: Flashing Tape 4" (0.25), Foam Can (0.15),
White Caulk (Insert) (1), Dark Bronze L-trim (12ft) (2), Dark Bronze Retro-L
Coil - 10ft (2), Dark Bronze Caulk (Insert) (4)
115 Second
Bedroom
35"
35-1/2"
55"
52-3/4"
Window: Acclaim™ Casement Single, Meets Egress, Right, Base Frame,
Exterior Dark Bronze, Interior White Performance Calculator: PG Rating: 40
| DP Rating: + 40 / - 40 Glass: All Sash: High Performance SmartSun with
HeatLock Glass, No Pattern Hardware: White, Wide Opening Hinge Screen:
Fiberglass, Full Screen Grille Style: Full Divided Light (FDL with spacer),
Permanently Applied Interior Wood Grille Grille Pattern: All Sash: Colonial
1w x 3h Misc: E-Series Window, Product Requirement for Permit/HOA
Construction: None Material: Flashing Tape 4" (0.25), Foam Can
116 Second
Bedroom
35"
35-1/2"
55"
52-3/4"
06/06/25 Page 5 / 40
Page 105
Order Summary
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
ID# ROOM SIZE DETAILS
(0.15), White Caulk (Insert) (1), Dark Bronze L-trim (12ft) (2), Dark Bronze
Retro-L Coil - 10ft (2), Dark Bronze Caulk (Insert) (4)
PRODUCTS: 15 WINDOWS: 14 PATIO DOORS: 0 ENTRY DOORS: 0 SPECIALTY: 0 MISC: 1 Updated 6/6/25
JOB NOTES
****Green Diamond Certified Commitment****
Here are important steps for the customer:
- punctuality and precision
- one lively but friendly large dog to be mindful of
Scheduling: 14 pocket/insert windows ***please send a detail oriented carpentry crew. There are some precision cut-backs of interior
stops in the living and dining room windows and this is a very original home with very discerning homeowners.
Stucco: N/A
Scaffolding: N/A
Permitting: Hold: check with the city to confirm that the homeowner can change from grids to no grids at the front of the house (living
room and dining room windows) and the back of the house they want to change from double hungs to single casements and match the
exterior color and grid pattern to the others at the back of the house (dark bronze, 3 x 1 lites FDL w/spacers applied)
1 inspection
HOA: No
Ordering: ***114,115,116 E-SERIES to match others at back of the house: DARK BRONZE exterior, WHITE interior, WHITE hardware E-
series: White painted interior, 7/8” FDL, Ovolo interior grids and glass stops, Chamfered exterior grids
all other windows are Fibrex: WHITE exterior, PINE interior, WHITE hardware.
All operating windows have fiberglass screens, PLEASE ORDER ALL SCREENS WITH WHITE FRAMES
Recast: Shiloh Witcosky: 100% COMMISSION
****Installer Notes****:
- L-trim exterior and insert up to stops interior on all windows **note 2 different exterior colors
06/06/25 Page 6 / 40
Page 106
Order Summary
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
JOB NOTES
- Living room and dining room units will need to have the interior stops cut back to accommodate our frame depths
- please be as careful as possible around the plant life, the homeowners will do what they can to trim back
Estimated Duration:
06/06/25 Page 7 / 40
Page 107
Order Summary
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
FLOORPLAN - 1ST FLOOR
UNIT NOTES
Haul Away, Dispose, City, County, State,
Home Owner Association Regulatory and
Compliance Fees (as applicable).
103 23 x 22 1/2
104 23 x 22 1/2
105 23 x 22 1/2
106 23 x 76 1/2
107 23 x 76 1/2
108 23 x 76 1/2
109 23 x 59 1/2
110 23 x 59 1/2
111 23 x 59 1/4
24 x 61
112 23 x 59 1/4
113 23 x 59 1/4
114 35 x 52 1/4
36 X 54
115 35 1/4 x 52 1/4
*See individual units for more notes.
06/06/25 Page 8 / 40
Page 108
Order Summary
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
JOB PHOTOS
Image 3 Image 1 Image 2
06/06/25 Page 9 / 40
Page 109
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
Misc
Misc: Misc, All Job Charges Miscellaneous charges, Production OHLJ Adjustment Fee, Quantity 1, Haul Away, Dispose, City,
County, State, Home Owner Association Regulatory and Compliance Fees (as applicable). Construction: None Material: None
UNIT NOTES
Haul Away, Dispose, City, County, State, Home Owner Association Regulatory and Compliance Fees (as
applicable).
UNIT CONSTRUCTION
UNIT MATERIALS
UNIT PHOTOS
06/06/25 Page 10 / 40
Page 110
106
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
106 Living Room
23-1/2" W 77" H
Window, Picture
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine Performance Calculator: PG Rating: 50 | DP Rating: +
50 / - 50 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern, Tempered Glass Grille Style: No Grille
Misc: None Construction: Precision cut back interior stops (1) Material: Flashing Tape 4" (0.25), Foam Can (0.15), White
Caulk (Insert) (3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
UNIT NOTES
23 x 76 1/2
UNIT CONSTRUCTION
Precision cut back interior stops 1
UNIT MATERIALS
COMMON
MATERIALS
(AUTO)
Flashing Tape 4"0.25 units
COMMON
MATERIALS
(AUTO)
Foam Can 0.15 cans
COMMON
MATERIALS
(AUTO)
White Caulk (Insert)3 x 6ft
COMMON
MATERIALS
(AUTO)
White L-Trim 12ft 2 x 12ft
COMMON
MATERIALS
(AUTO)
White Retro-L Coil 10ft 2 x 10ft
06/06/25 Page 11 / 40
Page 111
106
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
UNIT PHOTOS
Image 1 Image 2
06/06/25 Page 12 / 40
Page 112
107
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
107 Living Room
23-1/2" W 77" H
Window, Picture
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine Performance Calculator: PG Rating: 50 | DP Rating: +
50 / - 50 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern, Tempered Glass Grille Style: No Grille
Misc: None Construction: Precision cut back interior stops (1) Material: Flashing Tape 4" (0.25), Foam Can (0.15), White
Caulk (Insert) (3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
UNIT NOTES
23 x 76 1/2
UNIT CONSTRUCTION
Precision cut back interior stops 1
UNIT MATERIALS
COMMON
MATERIALS
(AUTO)
Flashing Tape 4"0.25 units
COMMON
MATERIALS
(AUTO)
Foam Can 0.15 cans
COMMON
MATERIALS
(AUTO)
White Caulk (Insert)3 x 6ft
COMMON
MATERIALS
(AUTO)
White L-Trim 12ft 2 x 12ft
COMMON
MATERIALS
(AUTO)
White Retro-L Coil 10ft 2 x 10ft
06/06/25 Page 13 / 40
Page 113
107
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
UNIT PHOTOS
Image 1 Image 2
06/06/25 Page 14 / 40
Page 114
108
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
108 Living Room
23-1/2" W 77" H
Window, Picture
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine Performance Calculator: PG Rating: 50 | DP Rating: +
50 / - 50 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern, Tempered Glass Grille Style: No Grille
Misc: None Construction: Precision cut back interior stops (1) Material: Flashing Tape 4" (0.25), Foam Can (0.15), White
Caulk (Insert) (3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
UNIT NOTES
23 x 76 1/2
UNIT CONSTRUCTION
Precision cut back interior stops 1
UNIT MATERIALS
COMMON
MATERIALS
(AUTO)
Flashing Tape 4"0.25 units
COMMON
MATERIALS
(AUTO)
Foam Can 0.15 cans
COMMON
MATERIALS
(AUTO)
White Caulk (Insert)3 x 6ft
COMMON
MATERIALS
(AUTO)
White L-Trim 12ft 2 x 12ft
COMMON
MATERIALS
(AUTO)
White Retro-L Coil 10ft 2 x 10ft
06/06/25 Page 15 / 40
Page 115
108
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
UNIT PHOTOS
Image 1 Image 2
06/06/25 Page 16 / 40
Page 116
109
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
109 Living Room
23-1/2" W 60" H
Window, Casement - Single
Window: Acclaim™ Casement Single, Left, Base Frame, Exterior White, Interior Pine Performance Calculator: PG Rating: 40 |
DP Rating: + 40 / - 40 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern Hardware: White Screen:
Fiberglass, Full Screen Grille Style: No Grille Misc: None Construction: Precision cut back interior stops (1) Material: Flashing
Tape 4" (0.25), Foam Can (0.15), White Caulk (Insert) (3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
UNIT NOTES
23 x 59 1/2
UNIT CONSTRUCTION
Precision cut back interior stops 1
UNIT MATERIALS
COMMON
MATERIALS
(AUTO)
Flashing Tape 4"0.25 units
COMMON
MATERIALS
(AUTO)
Foam Can 0.15 cans
COMMON
MATERIALS
(AUTO)
White Caulk (Insert)3 x 6ft
COMMON
MATERIALS
(AUTO)
White L-Trim 12ft 2 x 12ft
COMMON
MATERIALS
(AUTO)
White Retro-L Coil 10ft 2 x 10ft
06/06/25 Page 17 / 40
Page 117
109
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
UNIT PHOTOS
Image 1 Image 2 Image 3
06/06/25 Page 18 / 40
Page 118
110
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
110 Living Room
23-1/2" W 60" H
Window, Casement - Single
Window: Acclaim™ Casement Single, Right, Base Frame, Exterior White, Interior Pine Performance Calculator: PG Rating: 40 |
DP Rating: + 40 / - 40 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern Hardware: White Screen:
Fiberglass, Full Screen Grille Style: No Grille Misc: None Construction: Precision cut back interior stops (1) Material: Flashing
Tape 4" (0.25), Foam Can (0.15), White Caulk (Insert) (3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
UNIT NOTES
23 x 59 1/2
UNIT CONSTRUCTION
Precision cut back interior stops 1
UNIT MATERIALS
COMMON
MATERIALS
(AUTO)
Flashing Tape 4"0.25 units
COMMON
MATERIALS
(AUTO)
Foam Can 0.15 cans
COMMON
MATERIALS
(AUTO)
White Caulk (Insert)3 x 6ft
COMMON
MATERIALS
(AUTO)
White L-Trim 12ft 2 x 12ft
COMMON
MATERIALS
(AUTO)
White Retro-L Coil 10ft 2 x 10ft
06/06/25 Page 19 / 40
Page 119
110
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
UNIT PHOTOS
Image 1 Image 2
06/06/25 Page 20 / 40
Page 120
111
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
111 Dining
23-1/2" W 59-3/4" H
Window, Casement - Single
Window: Acclaim™ Casement Single, Left, Base Frame, Exterior White, Interior Pine Performance Calculator: PG Rating: 40 |
DP Rating: + 40 / - 40 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern Hardware: White Screen:
Fiberglass, Full Screen Grille Style: No Grille Misc: None Construction: Precision cut back interior stops (1) Material: Flashing
Tape 4" (0.25), Foam Can (0.15), White Caulk (Insert) (3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
UNIT NOTES
23 x 59 1/4
24 x 61
UNIT CONSTRUCTION
Precision cut back interior stops 1
UNIT MATERIALS
COMMON
MATERIALS
(AUTO)
Flashing Tape 4"0.25 units
COMMON
MATERIALS
(AUTO)
Foam Can 0.15 cans
COMMON
MATERIALS
(AUTO)
White Caulk (Insert)3 x 6ft
COMMON
MATERIALS
(AUTO)
White L-Trim 12ft 2 x 12ft
COMMON
MATERIALS
(AUTO)
White Retro-L Coil 10ft 2 x 10ft
06/06/25 Page 21 / 40
Page 121
111
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
UNIT PHOTOS
Image 1 Image 2
06/06/25 Page 22 / 40
Page 122
112
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
112 Dining
24" W 59-3/4" H
Window, Casement - Fixed Window
Window: Acclaim™ Casement Fixed Window, Base Frame, Exterior White, Interior Pine Performance Calculator: PG Rating: 40 |
DP Rating: + 40 / - 40 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern Grille Style: No Grille
Misc: None Construction: Precision cut back interior stops (1) Material: Flashing Tape 4" (0.25), Foam Can (0.15), White
Caulk (Insert) (3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
UNIT NOTES
23 x 59 1/4
UNIT CONSTRUCTION
Precision cut back interior stops 1
UNIT MATERIALS
COMMON
MATERIALS
(AUTO)
Flashing Tape 4"0.25 units
COMMON
MATERIALS
(AUTO)
Foam Can 0.15 cans
COMMON
MATERIALS
(AUTO)
White Caulk (Insert)3 x 6ft
COMMON
MATERIALS
(AUTO)
White L-Trim 12ft 2 x 12ft
COMMON
MATERIALS
(AUTO)
White Retro-L Coil 10ft 2 x 10ft
06/06/25 Page 23 / 40
Page 123
112
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
UNIT PHOTOS
Image 1 Image 2
06/06/25 Page 24 / 40
Page 124
113
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
113 Dining
23-1/2" W 59-3/4" H
Window, Casement - Single
Window: Acclaim™ Casement Single, Right, Base Frame, Exterior White, Interior Pine Performance Calculator: PG Rating: 40 |
DP Rating: + 40 / - 40 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern Hardware: White Screen:
Fiberglass, Full Screen Grille Style: No Grille Misc: None Construction: Precision cut back interior stops (1) Material: Flashing
Tape 4" (0.25), Foam Can (0.15), White Caulk (Insert) (3), White L-Trim 12ft (2), White Retro-L Coil 10ft (2)
UNIT NOTES
23 x 59 1/4
UNIT CONSTRUCTION
Precision cut back interior stops 1
UNIT MATERIALS
COMMON
MATERIALS
(AUTO)
Flashing Tape 4"0.25 units
COMMON
MATERIALS
(AUTO)
Foam Can 0.15 cans
COMMON
MATERIALS
(AUTO)
White Caulk (Insert)3 x 6ft
COMMON
MATERIALS
(AUTO)
White L-Trim 12ft 2 x 12ft
COMMON
MATERIALS
(AUTO)
White Retro-L Coil 10ft 2 x 10ft
06/06/25 Page 25 / 40
Page 125
113
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
UNIT PHOTOS
Image 1 Image 2
06/06/25 Page 26 / 40
Page 126
103
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
103 Living Room
23-1/2" W 23" H
Window, Picture
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine Performance Calculator: PG Rating: 50 | DP Rating: +
50 / - 50 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern Grille Style: No Grille Misc: None
Construction: Precision cut back interior stops (1) Material: Flashing Tape 4" (0.25), Foam Can (0.15), White Caulk (Insert)
(2), White L-Trim 12ft (1), White Retro-L Coil 10ft (1)
UNIT NOTES
23 x 22 1/2
UNIT CONSTRUCTION
Precision cut back interior stops 1
UNIT MATERIALS
COMMON
MATERIALS
(AUTO)
Flashing Tape 4"0.25 units
COMMON
MATERIALS
(AUTO)
Foam Can 0.15 cans
COMMON
MATERIALS
(AUTO)
White Caulk (Insert)2 x 6ft
COMMON
MATERIALS
(AUTO)
White L-Trim 12ft 1 x 12ft
COMMON
MATERIALS
(AUTO)
White Retro-L Coil 10ft 1 x 10ft
06/06/25 Page 27 / 40
Page 127
103
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
UNIT PHOTOS
Image 1 Image 2
06/06/25 Page 28 / 40
Page 128
104
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
104 Living Room
23-1/2" W 23" H
Window, Picture
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine Performance Calculator: PG Rating: 50 | DP Rating: +
50 / - 50 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern Grille Style: No Grille Misc: None
Construction: Precision cut back interior stops (1) Material: Flashing Tape 4" (0.25), Foam Can (0.15), White Caulk (Insert)
(2), White L-Trim 12ft (1), White Retro-L Coil 10ft (1)
UNIT NOTES
23 x 22 1/2
UNIT CONSTRUCTION
Precision cut back interior stops 1
UNIT MATERIALS
COMMON
MATERIALS
(AUTO)
Flashing Tape 4"0.25 units
COMMON
MATERIALS
(AUTO)
Foam Can 0.15 cans
COMMON
MATERIALS
(AUTO)
White Caulk (Insert)2 x 6ft
COMMON
MATERIALS
(AUTO)
White L-Trim 12ft 1 x 12ft
COMMON
MATERIALS
(AUTO)
White Retro-L Coil 10ft 1 x 10ft
06/06/25 Page 29 / 40
Page 129
104
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
UNIT PHOTOS
Image 1 Image 2
06/06/25 Page 30 / 40
Page 130
105
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
105 Living Room
23-1/2" W 23" H
Window, Picture
Window: Acclaim™ Picture, Base Frame, Exterior White, Interior Pine Performance Calculator: PG Rating: 50 | DP Rating: +
50 / - 50 Glass: All Sash: High Performance SmartSun with HeatLock Glass, No Pattern Grille Style: No Grille Misc: None
Construction: Precision cut back interior stops (1) Material: Flashing Tape 4" (0.25), Foam Can (0.15), White Caulk (Insert)
(2), White L-Trim 12ft (1), White Retro-L Coil 10ft (1)
UNIT NOTES
23 x 22 1/2
UNIT CONSTRUCTION
Precision cut back interior stops 1
UNIT MATERIALS
COMMON
MATERIALS
(AUTO)
Flashing Tape 4"0.25 units
COMMON
MATERIALS
(AUTO)
Foam Can 0.15 cans
COMMON
MATERIALS
(AUTO)
White Caulk (Insert)2 x 6ft
COMMON
MATERIALS
(AUTO)
White L-Trim 12ft 1 x 12ft
COMMON
MATERIALS
(AUTO)
White Retro-L Coil 10ft 1 x 10ft
06/06/25 Page 31 / 40
Page 131
105
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
UNIT PHOTOS
Image 1 Image 2
06/06/25 Page 32 / 40
Page 132
Page 133
114
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
RETRO/L/
FLAT/CEO/
CAULK
(AUTO)
Dark Bronze Caulk (Insert)4 x 3ft
UNIT PHOTOS
Image 1 Image 2 Image 3
06/06/25 Page 34 / 40
Page 134
Page 135
115
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
RETRO/L/
FLAT/CEO/
CAULK
(AUTO)
Dark Bronze Caulk (Insert)4 x 3ft
UNIT PHOTOS
Image 1 Image 2 Image 3
06/06/25 Page 36 / 40
Page 136
Page 137
116
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
dba: RENEWAL BY ANDERSEN OF SAN FRANCISCO
Legal Name: Jemico, LLC | License # CA CSLB#: 972702
30806 Santana St. | Hayward, CA 94544
Phone: (866) 420-4109 | Fax: (510) 751-5347 |
sfaccounting@renewalbayarea.com
Measure Tech: Jenn Collins,
RETRO/L/
FLAT/CEO/
CAULK
(AUTO)
Dark Bronze Caulk (Insert)4 x 3ft
UNIT PHOTOS
Image 1 Image 2
06/06/25 Page 38 / 40
Page 138
Installation Invoice
Mickael Forsman
16760 Magneson Loop
Los Gatos , CA 95032
Year Built: 1932
DESCRIPTION QUANTITY UNIT PRICE TOTAL
Base Unit Installation Charges, Full Frame & EJ Frame
Base Unit Installation Charges, Insert Frame & Base Frame
Install Picture Window - Universal (Universal, Base Frame),
100-109.99 UI
3 $230.00 $690.00
Install Casement Window (Base Frame), 80-89.99 UI 7 $215.00 $1,505.00
Install Fixed Window (Base Frame), 80-89.99 UI 1 $215.00 $215.00
Install Picture Window - Universal (Universal, Base Frame), 40-49.99
UI
3 $215.00 $645.00
Base Unit Installation Charges, Patio Doors
Base Unit Installation Charges, Entry Doors
Construction Charges
Custom - Precision cut back interior stops 11 $30.00 $330.00
3,385.00SUBTOTAL
Additional Items
ADDITIONAL
TOTAL
Installation Invoice | 16760 Magneson Loop, Los Gatos , CA 95032 Page 39 / 40
Page 139
Page 140
Existing material is woodProposed is Alum-wood clad
Existing material is woodProposed is Alum-wood clad
Existing material is woodProposed is Alum-wood clad
Existing material is woodProposed is Fibrex-wood composite
Existing material is woodProposed is Fibrex-wood composite
Existing material is woodProposed is Fibrex-wood composite
Existing material is woodProposed is Fibrex-wood composite
Scope of workReplace 14 retrofit windows (please note windows in living room sold with out grilles)Changing window style in 2nd bedroom(Casements from double hungs)
113
ATTACHMENT 5Page 141
RENEWALBYANDERSEN.COM RENEWALBYANDERSEN.COM18 19
Picture
WINDOWS
Transform your home with picture windows that can stand
alone beautifully or can be combined with other window
styles for added curb appeal.
ADAPTABLE
Match or change
your home’s
appearance by
combining picture
windows with
other windows.
STRONG
Using strong Fibrex®
material frames, our
picture windows easily
support the weight
of the heavy glass
commonly needed for
large picture windows.
VERSATILE
Like all of our
windows, picture
window glass is
available tempered,
tinted, or in a
wide variety of
decorative patterns.
Picture Windows / Pine Interior
Picture and Specialty Equal Leg Arch Combination Window / Oak InteriorPicture Window / White InteriorPicture Window / White InteriorPicture and Specialty Windows / Terratone Exterior
Picture Window Fixed Picture
Window
Combination
Window
Call your local Renewal by
Andersen representative
Click over to
RENEWALBYANDERSEN.COM
Visit your local Renewal
by Andersen showroom
“The new windows are gorgeous and
receive rave reviews from our visitors.”
ROBERT R.
Schedule Your
free In-Home
Consultation
Page 142
RENEWALBYANDERSEN.COM RENEWALBYANDERSEN.COM14 154 Wide opening hinge available to help meet egress requirements. Windows with wide open hinge cannot be cleaned from the interior. See your local code official for egress requirements in your area.
Casement Windows / White Interior / Simulated 2¼” Double-Hung Check Rail / Modified Colonial Grilles
Casement and Picture Combination Windows / Oak Interior
Awning Window / Pine InteriorCasement and Specialty Equal Leg Arch Combination Window / Oak Interior / Colonial Grilles Casement Window / Terratone Interior
“Renewal by Andersen® was by far the best
investment I've ever made for my home.”
PAUL M.
Casement
and Awning
WINDOWS
Casement windows catch a breeze and direct fresh air
indoors, allowing the most ventilation of any window style.
Awning windows let in fresh air, even on rainy days!
EASY
Casement windows open
wide to allow easy cleaning
of outside glass from the
inside4 and can be hinged
from the right or left.
SECURE
One lever positioned in
an easy-to-reach location
securely locks the casement
window at multiple points
for a weathertight seal.
EFFICIENT
Casement and awning
windows are our most
energy-efficient ventilating
window styles.
CONVENIENT
Awning windows are
recommended for use
over cabinets, counters, or
areas where opening and
closing require a reach.
Casement
Window
Awning
Window
Casement
Double Window
Use grilles
to mimic the
appearance of
double-hung
windows for
a historically
accurate look
Page 143
RENEWALBYANDERSEN.COM RENEWALBYANDERSEN.COM18 19
Picture
WINDOWS
Transform your home with picture windows that can stand
alone beautifully or can be combined with other window
styles for added curb appeal.
ADAPTABLE
Match or change
your home’s
appearance by
combining picture
windows with
other windows.
STRONG
Using strong Fibrex®
material frames, our
picture windows easily
support the weight
of the heavy glass
commonly needed for
large picture windows.
VERSATILE
Like all of our
windows, picture
window glass is
available tempered,
tinted, or in a
wide variety of
decorative patterns.
Picture Windows / Pine Interior
Picture and Specialty Equal Leg Arch Combination Window / Oak InteriorPicture Window / White InteriorPicture Window / White InteriorPicture and Specialty Windows / Terratone Exterior
Picture Window Fixed Picture
Window
Combination
Window
Call your local Renewal by
Andersen representative
Click over to
RENEWALBYANDERSEN.COM
Visit your local Renewal
by Andersen showroom
“The new windows are gorgeous and
receive rave reviews from our visitors.”
ROBERT R.
Schedule Your
free In-Home
Consultation
Page 144
PREPARED BY: Suray Nathan
Assistant Planner
110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874
www.losgatosca.gov
TOWN OF LOS GATOS
HISTORIC PRESERVATION COMMITTEE
REPORT
MEETING DATE: 08/27/2025
ITEM NO: 4
DATE: August 22, 2025
TO: Historic Preservation Committee
FROM: Joel Paulson, Community Development Director
SUBJECT: Consider a Request to Remove a Pre-1941 Property from the Historic
Resources Inventory for Property Zoned R-1D. Located at 24 Pleasant Street.
APN 529-26-016. Request for Review PHST-25-013. Exempt Pursuant to CEQA
Guidelines, Section 15061 (b)(3). Property Owner/Applicant: Swapnil Raut
and Rashmi Jadhav. Project Planner: Suray Nathan.
RECOMMENDATION:
Consider a request to remove a pre-1941 property from the Historic Resources Inventory for a
property zoned R-1D located at 24 Pleasant Street.
PROPERTY DETAILS:
1. Date primary structure was built: 1926 per County Assessor
2. Bloomfield Preliminary Rating: , historic & some altered, but still a contributor to the
district if there is one
3. Does property have an LHP Overlay? No
4. Is structure in a historic district? No
5. If yes, is it a contributor? N/A
6. Findings required? Yes
7. Considerations required? No
Page 145
PAGE 2 OF 3
SUBJECT: 24 Pleasant Street/ PHST-25-013
DATE: August 22, 2025
DISCUSSION:
The applicant is requesting approval to remove the pre-1941 residence from the Historic
Resources Inventory. The Santa Clara County Assessor’s Database lists a construction date of
1926, and the house first appears on the Sanborn Fire Insurance Maps in 1928 (Attachment 1).
The property is not within a historic district or LHP overlay, but it is included in the 1990 Anne
Bloomfield Survey (Attachment 2).
The applicant provided a Letter of Justification for the requested removal of a Mediterranean
Revival-style house (Attachment 3) that includes Town records showing some alterations and
additions, and photos of the current residence.
The applicant’s research and Town records show a building permit to construct a bedroom and
garage in 1957 (Attachment 3, page 12); however, no plans for the addition are found in the
Town records.
Town records also indicate that on February 14, 2000, the Building Division approved the
kitchen and bath remodeling, as well as the installation of all new windows into existing
openings without requiring a header change, except for the two patio doors at the rear
(Attachment 3, page 35).
CONCLUSION:
Should the Committee find that the structure has no historic significance or architectural merit,
a recommendation of approval of the request to remove the property from the Historic
Resources Inventory would be forwarded to the Community Development Director. Once
approved by the Director, any proposed alterations would not return to the Committee.
FINDINGS:
A. Findings - related to a request for a determination that a pre-1941 primary structure has no
historic significance or architectural merit.
In evaluating a request for a determination of historic significance or architectural merit,
the Historic Preservation Committee shall consider the following:
1. The structure is not associated with events that have made a significant contribution
to the Town;
2. No Significant persons are associated with the site;
3. There are no distinctive characteristics of type, period or method of construction or
representation of work of a master;
4. The structure does not yield information to Town history; or
5. The integrity has been compromised such that the structure no longer has the
potential to convey significance.
Page 146
PAGE 3 OF 3
SUBJECT: 24 Pleasant Street/ PHST-25-013
DATE: August 22, 2025
ATTACHMENTS:
1. Sanborn Fire Maps
2. 1990 Anne Bloomfield Survey
3. Letter of Justification
Page 147
This Page
Intentionally
Left Blank
Page 148
1928
24 Pleasant St
ATTACHMENT 1Page 149
1944
24 Pleasant St
Page 150
1956
24 Pleasant St
Page 151
This Page
Intentionally
Left Blank
Page 152
dln.n.e !Bfoom(u.fd
ARCHITECTURAL /CULTURAL SUR VEY
LOS GATOS RESEARCH
File address ~ -:.1 -;;//"~"'"' "" -; r ----~--------~-------------
ARCHITECTURAL HISTORY
(4 1 5) 922-1063
2229 WEBSTER STREET
SAN FRANCISCO. CA 94 1 1 5
PARCEL MAP INFORMATION
Parcel # 5 ::J'/<? .. ~-~.·h Lot size: o~o
,......
~ r·,.. 5 !:;
front f t . x 1~~ f t. deep
Lot shape: Rectangle~L ___ Rectangle with small rear jog___ Ot her ___________________ __
Location: N_ S_._ E_L W_ side of ____ -p'----------St Ave/ Other -------
distance to cross st :C. :Z'B'U
at NE NW SE SW corner of -----------------------
HISTORIC INFORMATION ON PARCEL MAP , .
Old tract or subdivision name ,e I /t//,..,1tC. 5 vP Old Block # Old lot # ~ 0 ----
FIELD SURVEY INFORMATION (handwritten in red)
Preliminary rating .,/ Estimated age /1~0~ Style / lf:.d!-/e l~ )~ /• /, # storieL-
Alterations a /,_ ·~·r I' J ~·
Other ---------------------------------------------------------------------------------
0UNTY ASSESSOR--PROPERTY CHARACTERISTICS (paste on copy) EFFective date '--------
OWNERSHIP SHOWN ON MAPS
Source Source Source Location of property, or Lot Owner
Name Date Page Old -tract/block/lot Size Name ---------
1891
Blk Book 1908
Survey 1944
I 1
I
MISCELLANEOUS
Nat ional Register listed date'--------------------
PHOTOS : Roll/frame #O~t//
'
Date 2.''EJ -/:..
County Inventory 1979 ____________ ~~---------
Town of Los Gatos: Designation __ Recognition __
District Name -------------------------------
Previous Survey
Gebhard: page # illustration page #
Butler/Junior League ----
ATTACHMENT 2Page 153
This Page
Intentionally
Left Blank
Page 154
Historic Preservation Committee, Town of Los Gatos Tel: 309-532-9911, 385-887-2519
110 E. Main St Date: July 15 th , 2025
Los Gatos, CA 95030
24 Pleasant St - Request to Remove from Historic Register
Dear Members of the Historic Preservation Committee,
We are writing to formally request that our property, located at 24 Pleasant Street, be removed from the
Town of Los Gatos Historic Registry.
After careful research and consideration, we believe the property no longer meets the criteria for continued
historic designation. Although it was originally included due to its pre-1941 construction date, we respectfully
submit that it lacks the architectural integrity, cultural significance, and historical relevance necessary to
justify its continued inclusion on the registry.
Key Points Supporting the Request:
1. Research Findings (Conducted with Librarian Shawnte Santos at the Los Gatos Library):
● The property is not part of the Historic Property Research Collection.
● The property address is not in a Historic District and does not have a LHP Overlay.
● The structure does not yield information to Town history; It is not recognized in the 1989 Ann
Bloomfield Architectural Survey forms as a contributing or significant structure.
● The property is not mentioned on the Bell Ringers list.
● The property structure does not have known associations with historically significant individuals or
events to the town.
● The 1941 Tax Assessment and Santa Clara County historic records make no references to
Pleasant Street as historically designated.
● No historically significant individuals appear to be associated with the property. Early owners —
including Alexander E. P., W.H. Moron, Bert Homes, J.R. Gibson, Douglas Gravelle, Mrs. Dorothy
McKevitt, and Michael Blackt — do not have any known ties to notable historical events or
contributions.
2.Significant Alterations Over Time:
● The integrity of the structure has been compromised as the original front and side windows have
been replaced.
● A substantial rear addition has been built, including an extra bedroom and expanded living area.
● The current roofline and exterior appearance no longer reflect the original architectural style.
In Closing:
We greatly value the rich history and character of Los Gatos and remain committed to maintaining the charm
and aesthetic of the neighborhood. Our request is simply to allow us the flexibility to make thoughtful
updates that support our family’s needs, while staying aligned with the community’s visual traditions.
We appreciate your time and consideration, and we are happy to provide any additional documentation or
participate in further discussion as needed.
Sincerely,
Swapnil Raut & Rashmi Jadhav
ATTACHMENT 3
Page 155
1929 McMillan and McMillan official map of Santa Clara County does not show Pleasant St
on the map:
Page 156
Page 157
Page 158
Page 159
Page 160
Page 161
Page 162
Page 163
Page 164
Page 165
Page 166
Page 167
Page 168
Page 169
Page 170
Page 171
Page 172
Page 173
Page 174
Page 175
Page 176
Page 177
Page 178
Page 179
Page 180
Page 181
Page 182
Page 183
Page 184
Page 185
Page 186
Page 187
Page 188
Page 189
Page 190
PREPARED BY: Samina Merchant
Associate Planner
110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874
www.losgatosca.gov
TOWN OF LOS GATOS
HISTORIC PRESERVATION COMMITTEE
REPORT
MEETING DATE: 08/27/2025
ITEM NO: 5
DATE: August 22, 2025
TO: Historic Preservation Committee
FROM: Joel Paulson, Community Development Director
SUBJECT: Consider a Request for Preliminary Review to Construct a New Second-Story
Addition and Exterior Alterations to an Existing Pre-1941 Single-Family
Residence on Property Zoned R-1D. Located at 245 Los Gatos Boulevard. APN
529-24-024. Request for Review Application PHST-25-011. Exempt Pursuant
to CEQA Guidelines, Section 15301: Existing Facilities. Property Owner:
Michael Phung. Applicant: Andres Johnson. Project Planner: Samina
Merchant.
RECOMMENDATION:
Consider a request for preliminary review to construct a new second-story addition and exterior
alterations to an existing pre-1941 single-family residence on property zoned R-1D, located at
245 Los Gatos Boulevard.
DISCUSSION:
On June 25, 2025, the Committee considered proposed exterior alterations and additions to an
existing pre-1941 single-family residence (Attachment 1). The Committee provided the
following feedback:
Reposition the second-story addition closer to the front and create a balanced massing with
the existing single-story residence to achieve a unified overall appearance; and
Incorporate additional embellishments to support the architectural style.
The applicant submitted revised plans and a letter summarizing their response to the
Committee’s direction (Attachment 2). The revised plans include the following modifications:
Forward shift of the second-story addition to improve massing and integration with the
existing residence while retaining the original façade; and
Addition of Spanish/Mission Revival features: roofline articulation (including corbels and
clay roof tiles), tile vents, colonial-style windows, decorative ironwork, and stucco finishes.
Page 191
PAGE 2 OF 2
SUBJECT: 245 Los Gatos Boulevard/ PHST-25-011
DATE: August 22, 2025
CONSIDERATIONS:
A. Considerations.
Sec. 29.80.290. Standards for review.
In evaluating applications, the deciding body shall consider the architectural style, design,
arrangement, texture, materials and color, and any other pertinent factors. Applications
shall not be granted unless:
__X__ For pre-1941 structures, the proposed work will neither adversely affect the exterior
architectural characteristics or other features of the property which is the subject of
the application.
B. Residential Design Guidelines.
Section 3.9 of the Town’s Residential Design Guidelines offers recommendations for
construction of additions to existing residences (Attachment 7 of Exhibit 1, June 25, 2025
Historic Preservation Committee Staff Report).
CONCLUSION:
The applicant requests a preliminary review to construct a new second-story addition and
exterior alterations to an existing pre-1941 single-family residence on property zoned R-1D,
located at 245 Los Gatos Boulevard. A new second-story addition, if not triggering a technical
demolition, would be processed under a future Minor Residential Development application.
This application would return to the Committee for a formal recommendation to be forwarded
to the Community Development Director and the application would continue through the
Minor Residential Development process.
EXHIBITS:
1. June 25, 2025, Historic Preservation Committee Staff Report
2. Response Letter
3. Revised Development Plans
Page 192
PREPARED BY: Samina Merchant
Associate Planner
110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874
www.losgatosca.gov
TOWN OF LOS GATOS
HISTORIC PRESERVATION COMMITTEE
REPORT
MEETING DATE: 06/25/2025 ITEM NO: 6
DATE: June 20, 2025
TO: Historic Preservation Committee (HPC)
FROM: Joel Paulson, Community Development Director
SUBJECT: Consider a Request for Preliminary Review to Construct a New Second-Story
Addition and Exterior Alterations to an Existing Pre-1941 Single-Family
Residence on Property Zoned R-1D. Located at 245 Los Gatos Boulevard. APN
529-24-024. Request for Review Application PHST-25-011. Exempt Pursuant
to CEQA Guidelines, Section 15301: Existing Facilities. Property Owner:
Michael Phung. Applicant: Andres Johnson. Project Planner: Samina
Merchant.
RECOMMENDATION:
Consider a request for preliminary review to construct a new second-story addition and exterior
alterations to an existing pre-1941 single-family residence on property zoned R-1D, located at
245 Los Gatos Boulevard.
PROPERTY DETAILS:
1.Date primary structure was built: 1924 per County Assessor’s Database; 1920s per Anne
Bloomfield Survey
2.Bloomfield Preliminary Rating: “+” Historic and intact or worthy of special note
3.Does the property have an LHP Overlay? No
4.Is the structure in a historic district? No
5.If yes, is it a contributor? N/A
6.Findings required? No
7.Considerations required? Yes
BACKGROUND:
The subject property is located on the west side of Los Gatos Boulevard north of the
intersection at Simons Way. The County Assessor reports that the residence was constructed in
1924. The 1990 Anne Bloomfield Survey describes the residence as being built in a Bungalow
style with an estimated construction date of the 1920s (Attachment 1). The Bloomfield Survey
rates the residence as historic and intact or worthy of special note.
EXHIBIT 1Page 193
PAGE 2 OF 4 SUBJECT: 245 Los Gatos Boulevard/ PHST-25-011 DATE: June 20, 2025
The Sanborn Fire Insurance Maps do not provide coverage for the property until 1928. The
footprint of the residence remains consistent between the 1928 and the 1956 maps
(Attachment 2). Town records include a 2022 Building Permit for the demolition of unpermitted
and permitted areas, construction of a new addition, and exterior remodel (Attachment 3).
DISCUSSION:
The applicant provided a Letter of Justification for the proposed project and photos of the
existing residence (Attachments 4 and 5). The applicant is requesting a preliminary review by
the Committee to provide feedback on the proposed second-story addition and exterior
alterations to the existing home (Attachment 6).
The project proposes a 560-square-foot second-story addition located at the rear (western
elevation) of the existing one-story home. First-floor improvements include an interior remodel
and exterior modifications. The new second floor would accommodate two bedrooms and two
bathrooms.
The existing one-story home is 14 feet two inches tall and features a low-pitched composite
shingle roof. It includes overhanging eaves with the front eave line finished in barrel tiles. The
proposed second story would incorporate a similar roof style, increasing the maximum building
height to 24 feet one inch. Existing materials include textured stucco, double-hung windows,
and composite shingles. The proposed design would match these materials and introduce clay
roof tiles. Information regarding window and door materials was not provided for this
preliminary review.
CONSIDERATIONS:
A.Considerations.
Sec. 29.80.290. Standards for review.
In evaluating applications, the deciding body shall consider the architectural style, design,
arrangement, texture, materials and color, and any other pertinent factors. Applications
shall not be granted unless:
__X__ For pre-1941 structures, the proposed work will neither adversely affect the exterior
architectural characteristics or other features of the property which is the subject of
the application.
B.Residential Design Guidelines.
Section 3.9 of the Town’s Residential Design Guidelines offers recommendations for
construction of additions to existing residences (Attachment 7).
Page 194
PAGE 3 OF 4 SUBJECT: 245 Los Gatos Boulevard/ PHST-25-011 DATE: June 20, 2025
CONCLUSION:
Consider a request for preliminary review to construct a new second-story addition and exterior
alterations to an existing pre-1941 single-family residence on property zoned R-1D, located at
245 Los Gatos Boulevard. A new second-story addition, if not triggering a technical demolition,
is processed under a Minor Residential Development application. This application would return
to the Committee for a formal recommendation to be forwarded to the Community
Development Director and the application would continue through the Minor Residential
Development process.
ATTACHMENTS:
1. 1990 Anne Bloomfield Survey
2. Sanborn Fire Maps
3. Town Building Permit Record
4. Letter of Justification
5. Photographs
6. Development Plans
7. Section 3.9, Residential Design Guidelines
Page 195
This Page
Intentionally
Left Blank
Page 196
dfnn£· !Bfoom(i.Lld
UCHITBC~~~~ SURVBY
RAMI! RBI!IBARCH
ARCHITECTURAL HISTORY
141 Sl 922·1 063
2229 WEBSTER STREET
SAN FRANCISCO. CA 941 1 S
~(~H~,b~~~g.~~inthn,e~)---------------------------------
'\ddresses associated with ~~~ame._.:;;;~;.....4~.£::;;........;L:;;;;.;..:::~;:;;....;E;:;. ____________________________ _
..celevant dates: eonstr~~tion. ___ • birth. ___ • daath. ___ • other __________ _
I. DIIl!CTORY SBARCH (City Dinetoriee, COUDty Dlreetoriea, TelepnoMI Booka, aoc:iety directoriea, ate.)
Liatin"' l......,.v ... ~t ... aw•_..,-aa shown• use • for boldfaeel ~Book
f?;?.
NaJM/Claaaified RaatHna
~pi
f~ I
!:U;v Sa .... J~ ;:;t~s )/J&J ,t /i 6 /e/
~]) "--1"'1 .., wt!J r--:, ~~ J&5 #' cE"'/;z) r:~~ oc.ZJ h ::Z.L/6 s..v .... _j
f
{iN title date
BIOGRAPHICAL SIARCR, indexea 6 other alphabetical lietinge. llark 'X' Unfd .or •J• (aothiD9 f~) et each eouroe you try. Liat UndblcJa below.
Los Gatos Library:
City directories (name .& street index)
~Historic Collection Index (green boxes)
Thompson & West, 1876 (bio index)
---Pen Pictures, 1888 (bio index)
California History Center, De Anza College:
___ Biographical file
Photo collection
---Sunshine Fruit & Flowers, 1895 (bio index)
---Guinn, 1904 (bio index)
Sawyer, 1922 (bio index)
~ Extended index to Bruntz
_r_Blo index of Nunr:oe Frazer,
___ Photo collection (2 boxes)
Los Gatos Museum (Forbes Mill):
San Jose Historical Museum:
___ Great Registers (of voters)
Indexes
Photo collection
1881 (Survey box)
Other sources:
___ Death records by year
___ Funeral records (index
____ Indexes, California Historical t::uarterly
State Library Information Index (fiche)
---State Library-S.F. Newspaper Index (")
cards to big books_) __ _
Photo collection
III. LIST ALL ll!FEJU!!HCES FROM ABOVE. Find tham. Copy good material 6 attach. Or copy below if only
a few worda. Or explain why not relevant (as, wrong ~raon).
L:7 Continued on Reverse
Page 199
cflnne 93foom{£E.fd
ARCHITECTURAL SURVEY
ASSESSMENT ROLL RESEARCH
File Address d~~-L~B Tract/Block/Lot J? :;( r lie r-1 j .,;.;--Jtj pr-e-.. .,..,
~
ARCH I TEC . .(AL HISTORY
141 5) 922-1 063
29 WEBSTER STREET
RANCISCO. CA 9411 5
22
SAN F
Assessments are filed by last name of property owner, but not necessarily in alphabetical order . Some years there is an
alue of
every year
index inside the volume or in a separate book. The goal of a search is to find the years when the assessed v
"improvements" (buildings) changed from 0 to over $500, or when that figure rose by $500 or mroe. Write down
and name you try, including the years when you find nothing. Ditto marks are fine.
-----Lot Identification or Boundaries----------Assessment for--
Tract or Block or Lot # or Improve-
Date Page Name Acres N Bdy E Bdy S Bdy W Bdy Land ments Other --Info.
!qJ(p lo 4 _J r-..-.-~~/~ 8a~fletf Lf $..2~-$ -
I 9..9u I 1 /7 r7 4 6~S" -
I
/1.n1t1ais date
Page 200
1928
ATTACHMENT 2
Page 201
1944Page 202
1956Page 203
This Page
Intentionally
Left Blank
Page 204
Page 205
Page 206
Page 207
Page 208
Page 209
Page 210
Page 211
This Page
Intentionally
Left Blank
Page 212
June 5,2025
Historic Preservation Committee
Town of Los Gatos
110 E. Main Street
Los Gatos, CA 95030
Subject: Request for Review and Approval – Second Story Addition at 245 Los Gatos
Boulevard
Dear Members of the Historic Preservation Committee,
I am writing to formally request review and approval for a proposed second-story addition
to the residence located at 245 Los Gatos Boulevard. This property is listed as a
contributing structure in the Los Gatos Historic Resources Inventory; however, according
to the historical assessment prepared by Anne Bloomfield, the portion of the home where
the addition is planned is not deemed historically significant.
The proposed addition is situated at the rear of the home, away from the primary historical
facade, and has been carefully designed to be consistent with and complementary to the
presumed original architectural style of the home—a Spanish-style bungalow. Our intent is
to preserve and enhance the home’s historic character while making thoughtful
improvements that support the long-term livability of the property.
We understand and respect the importance of maintaining the architectural integrity of the
neighborhood and are committed to ensuring that all additions are in harmony with the
historic context of the area. The design incorporates stylistic features in keeping with the
home's original period and scale, while maintaining a clear visual distinction between the
original structure and the new work, in accordance with historic preservation best
practices.
Please find attached the historical research documentation by Anne Bloomfield and
preliminary drawings of the proposed addition for your consideration. We welcome any
guidance or recommendations the Committee may have to ensure the project aligns with
preservation goals.
dwelling labdesign@dwelling-lab.comdwelling-lab.com(312) 952-9680
w. dwelling-lab.com | e. design@dwelling-lab.com | p. 312.952.9680 | a. 21 El Caminito, Walnut Creek, CA 94598
Sincerely,
Neil Ginty
Founder & Principal Architect
M.A., B.Arch, NCARB, Registered Architect ATTACHMENT 4
Page 213
This Page
Intentionally
Left Blank
Page 214
Existing Residence Photographs
Front (East)
Page 215
Existing Residence Photographs
Side (South)
Page 216
Existing Residence Photographs
Rear
Page 217
Existing Residence Photographs
Side (North side looking towards east)
Page 218
Existing Residence Photographs
Side (North side looking towards east)
Page 219
ABBREVIATIONS
&AND
@ AT
A.B.ANCHOR BOLT
A.C.AIR CONDITIONING
ACOUST. ACOUSTICAL
A.C.T. ACOUSTICAL CEILING TILE
A.D.AREA DRAIN
A.F.F. ABOVE FINISHED FLOOR
ALUM. ALUMINUM
ARCH. ARCHITECT OR ARCHITECTURAL
BLKG. BLOCKING
B.P.BUILDING PAPER
B.O.BOTTOM OF
CAB.CABINET
CATV CABLE TELEVISION
C.C.CENTER TO CENTER
C.I.P.CAST-IN-PLACE
C.J.CONTROL JOINT
C.L.CENTER LINE
CLG.CEILING
CLR.CLEAR
C.O.CLEAN OUT
CONC. CONCRETE
DEMO. DEMOLITION OR DEMOLISH
DEPT. DEPARTMENT
DIA.DIAMETER
DIM.DIMENSION
D.W.DISHWASHER
DWG(S). DRAWING(S)
(E)EXISTING
EA.EACH
E.B.EXPANSION BOLT
ELEC. ELECTRICAL
ELEV. ELEVATION
E.O.S. EDGE OF SLAB
EQ.EQUAL
SPEC. SPECIFICATION (S)
SQ.SQUARE
S.T.C. SOUND TRANSMISSION COEFFICIENT
STD.STANDARD(S)
STL.STEEL
TB.TOWEL BAR
T.B.D. TO BE DETERMINED
T & G TONGUE AND GROOVE
THR.THRESHOLD
T.O.TOP OF
T.O.B. TOP OF BEAM
T.O.P. TOP OF PAVING
T.O.S. TOP OF SLAB
T.O.STL. TOP OF STEEL
T.V.TELEVISION
TYP.TYPICAL
V.B.VAPOR BARRIER
VERT. VERTICAL
V.I.F.VERIFY IN FIELD
W/WITH
W.C.WATER CLOSET
WD.WOOD
W/D WASHER/DRYER
WH.WATER HEATER
W/O WITHOUT
WP.WATERPROOF / WEATHERPROOF
WT.WEIGHT
YD.YARD
H.B.HOSE BIB
H.D.HOLD DOWN
HT.HEIGHT
HTG.HEATING
HVAC HEATING, VENTILATION & AIR CONDITIONING
H.W.HOT WATER
IN.INCH(ES)
LAV.LAVATORY
LBS.POUNDS
L.F.LINEAR FOOT
L.V.T. LUXURY VINYL TILE
F.A.U. FORCED AIR UNIT
F.C.U. FAN COIL UNIT
F.D.FLOOR DRAIN
F.F.FINISH FLOOR
FIN.FINISH OR FINISHED
FLR.FLOOR
FT.FOOT / FEET
FTG.FOOTING
G.GAS
GA.GAUGE
G.C.GENERAL CONTRATOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
G.L.GRIDLINE
G.W.B. GYPSUM WALL BOARD
GYP.GYPSUM
MACH. MACHINE
MANUF. MANUFACTURER
MAX. MAXIMUM
M.B.MACHINE BOLT
MDF MEDIUM DENSITY FIBERBOARD
M.E.P. MECHANICAL/ELECTRICAL/PLUMBING
MEMB. MEMBRANE
MIN.MINIMUM
MIR.MIRROR
MISC. MISCELLANEOUS
MTL.METAL
MW.MICROWAVE
(N)NEW
N/A NOT APPLICABLE
O/OVER
O.C.ON CENTER
PLYWD. PLYWOOD
PLUMB. PLUMBING
P.S.F. POUNDS PER SQUARE FOOT
P.S.I.POUNDS PER SQUARE INCH
P.T.PRESSURE TREATED
P.V.C. POLY VINYL CHLORIDE PIPE
R.C.P. REFLECTED CEILING PLAN
REQ'D REQUIRED
RET.RETAIN / RETAINING
REV.REVISION
S.C.SOLID CORE
SIM.SIMILAR
DRAWING INDEXSYMBOLS
ROOM NAME
101
Name
Elevation
1
1
A101
A
A
A
A
A101
1
1
A1.01
88
1
A1.01
ROOM NAME & NUMBER
WINDOW NUMBER
DOOR NUMBER
ELEV. HT. REFERENCE
NORTH ARROW
MATERIAL TAG
REVISION
INTERIOR ELEVATION
DETAIL REFERENCE
ELEVATION REFERENCE
SECTION REFERENCE
ASSEMBLY TYPE REFERENCE
DETAIL CALLOUT
PROJECT NORTH
TRUE NORTH
999
A101
1 SIM
XX-00
ROOM NUMBER
DOOR NUMBER (SEQUENTIAL)
SITE INFORMATION
ADDRESS:245 LOS GATOS BLVD, LOS GATOS, CA 95030
APN:529 24 024
CLIMATE ZONE:3
SEISMIC DESIGN CATEGORY: (D0, D1, D2)
SCOPE OF WORK:
1ST FLOOR
REMODEL OF EXISTING SINGLE FAMILY DWELLING INCLUDING BATHROOM, KITCHEN,
AND ASSOCIATE PLUMBING AND ELECTRICAL WORKS.
2ND FLOOR
ADDITION TO EXISTING SINGLE FAMILY DWELLING INCLUDING TWO NEW BATHS AND
TWO BEDROOMS WITH A LAUNDRY CLOSET.
PROJECT DATA
ZONING DATA
YEAR BUILT:1924
ASSESSOR'S PARCEL NUMBER (BLOCK/LOT): 24
PLANNING DISTRICT:
NEIGHBORHOOD (PLANNING):
ZONE:R1-D
HEIGHT & BULK:
APPLICABLE CODES:
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA RESIDENTIAL CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA FIRE CODE
NATIONAL FIRE PROTECTION ASSOCIATION (BOOKLET 101)
CALIFORNIA ENERGY COMMISSION TITLE 24
2022 CALIFORNIA GREEN BUILDINGS STANDARDS CODE
ALL OTHER APPLICABLE CITY AND COUNTY LAWS AND ORDINANCES
PARCEL AREA CALCULATIONS
PARCEL AREA:7,000 SQ.FT (0.16 ACRES)
GROSS FLOOR AREA:
FIRST FLOOR 1,748 SF
SECOND FLOOR 560 SF
TOTAL FLOOR AREA 2,308 SF
ALLOWABLE F.A.R. .35 - (7,000-5/25 X.20) = .33
PROPOSED F.A.R..33 X 7,000 = 2,310
MAX ROOF HEIGHT 30'-0"
PROPOSED HEIGHT 24'-1"
BUILDING DATA
OCCUPANCY:R-3 (SINGLE FAMILY DWELLING)
CONSTRUCTION TYPE:V-B
FIRE SPRINKLERS:NO
(E) SQ. FT.:1,748 SF
PROPOSED SQ. FT.:2,308 SF
VICINITY MAP
PROJECT
LOCATION
ARCHITECT:
DWELLING LAB
NEIL GINTY
21 EL CAMINITO
WALNUT CREEK, CA 94598
CONTACT:
PHONE:(312) 952-9680
EMAIL:design@dwelling-lab.com
WEBSITE dwelling-lab.com
OWNERS:
MONIQUE PHAM
PROJECT DIRECTORY
0
Sheet Title
Sheet No.
Scale
Drawn By:Checked By:
Job Number:
Issued For
Date:
Job Address
Job Title
Revision No.Date
Written dimensions on these drawings shall have precedence over scaled
dimensions. Drawings shall not be scaled. Contractors shall verify, and be
responsible for, all dimensions and conditions shown by these drawings.
Shop details must be submitted to this office for approval before proceeding
with fabrications. The drawings and their design content are the sole
property of Dwelling Lab, Inc. and may not be reused or reproduced in any
manner without our express written consent.
2'4'8'16'
Agency Approvals t.312.952.9680 | e.design@dwelling-lab.com | w.dwelling-lab.coma. 21 El Caminito, Walnut Creek, CA 94598As indicated
5/30/2025 3:31:12 PMA0.01
PROJECT
DATA_RESIDENTIAL
245 LOS GATOS BLVD, LOS GATOS,
CA 95030
5/7/2025
Project Status
Project Number
245 LOS GATOS BLVD
Author Checker
EXISTING PHOTOGRAPH
GENERAL NOTES
1. CONTRACTOR IS HEREBY SPECIFICALLY DIRECTED AS A CONDITION OF THE
CONTRACT TO ACQUAINT HIMSELF/HERSELF WITH THE ARTICLES CONTAINED
IN THE GENERAL NOTES AND TO NOTIFY AND APPRISE ALL SUBCONTRACTORS
AND ALL OTHER PARTIES OF THE CONTRACT OF, AND BIND THEM TO, ITS
CONDITIONS.
2. DRAWINGS OF BASE BUILDING CONDITIONS ARE GENERATED FROM AS-BUILT
DRAWINGS AND LIMITED FIELD OBSERVATION BY THE ARCHITECT. ACTUAL
CONDITIONS MAY DIFFER FROM THOSE SHOWN.
3. CONTRACTOR SHALL FILE, OBTAIN AND PAY FEES FOR BUILDING
DEPARTMENT AND ALL OTHER AGENCY APPROVALS AND PERMITS,
CONTROLLED INSPECTIONS, AND FINAL SIGN-OFFS FOR PROJECT
COMPLETION. COPIES OF TRANSACTIONS SHALL BE FORWARDED TO THE
OWNER PRIOR TO COMMENCING WORK.
4. CONTRACTOR SHALL VERIFY THAT DRAWINGS ARE THE LATEST ISSUANCE
PRIOR TO BEGINNING OF CONSTRUCTION.
5. CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OUTSIDE
VENDORS INCLUDING, BUT NOT LIMITED TO, TELEPHONE, DATA AND "OWNER'S
FORCES". CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL
DO THE CUTTING, FITTING AND PATCHING REQUIRED TO RECEIVE THE WORK
OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND
SPECIFICATIONS.
6. ALL IDENTIFIED SCOPE OF WORK SHALL BE PROVIDED NEW, UNLESS
OTHERWISE NOTED.
7. WORK NOT SPECIFICALLY DETAILED, NOTED OR SPECIFIED, SHALL BE THE
SAME AS SIMILAR PARTS THAT ARE DETAILED, NOTED OR SPECIFIED.
8. IN THE EVENT OF INCONSISTENCIES AMONG THE CONTRACT DOCUMENTS,
THE ARCHITECT SHALL INTERPRET THEM WHEN ASKED TO DO SO BY THE
OWNER OR CONTRACTOR. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR
THE RESULTS OF SUCH INTERPRETATIONS MADE BY OTHERS.
9. THE GENERAL CHARACTER OF DETAIL WORK IS SHOWN ON THE CONTRACT
DOCUMENTS. SUBSEQUENT CLARIFICATIONS MAY BE MADE BY ADDITIONAL
LAYOUTS OR LARGE SCALE OR FULL SIZE DETAILS.
10. VERIFY ALL EQUIPMENT SIZES BEFORE BEGINNING WORK
11. "TYPICAL" OR "TYP." SHALL MEAN THAT THE CONDITION IS REPRESENTATIVE
FOR SIMILAR CONDITIONS THROUGHOUT, UNLESS OTHERWISE NOTED.
DETAILS OR DIMENSIONS ARE USUALLY KEYED, AND NOTED "TYP" ONLY WHEN
THEY FIRST OCCUR.
12. "SIMILAR" OR "SIM." MEANS COMPARABLE CHARACTERISTICS FOR THE
CONDITIONS NOTED. VERIFY DIMENSIONS, ORIENTATION, AND CONDITIONS ON
PLANS AND ELEVATIONS
13. ARCHITECT SHALL HAVE THE AUTHORITY TO REJECT ANY WORK THAT IS NOT
IN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS
1. REFER TO TITLE SHEET FOR APPLICABLE CODES
2. GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, CODES,
RULES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK. IF THE
CONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT
VARIANCE THEREWITH, PROMPTLY NOTIFY THE PROJECT MANAGER AND/OR
ARCHITECT. NECESSARY CHANGES SHALL BE MADE IN ACCORDANCE WITH
THE GENERAL CONDITIONS.
3. IF CONTRACTOR KNOWINGLY PERFORMS ANY WORK WHICH IS CONTRARY TO
SUCH LAWS, ORDINANCES, CODES, RULES AND REGULATIONS, HE/SHE SHALL
PROMPTLY MAKE ALL CHANGES AS REQUIRED TO COMPLY THEREWITH AND
BEAR ALL COSTS ARISING THEREFROM.
4. CONFLICTS: IN CASE OF CONFLICTS IN THE REQUIREMENTS OF AUTHORITIES
HAVING JURISDICTION, THE MOST RESTRICTIVE REQUIREMENTS SHALL
GOVERN.
5. WHERE CODES OR REGULATIONS, OTHER THAN THOSE LISTED IN THIS
SECTION, ARE REFERRED TO IN VARIOUS SECTIONS OF THE SPECIFICATIONS.
IT SHALL BE UNDERSTOOD THAT THEY APPLY TO THIS WORK AS FULLY AS IF
CITED HEREIN.
6. ALL COMBUSTIBLE MATERIALS SHALL MEET APPLICABLE CODES. WOOD
SHALL BE FIRE RETARDANT TREATED WHERE REQUIRED BY LOCAL BUILDING
CODES AND BUILDING OWNER'S REQUIREMENT'S.
7. FOR MAXIMUM FLOW RATES FOR PLUMBING FIXTURES, REFER TO
STANDARDS FOR PLUMBING FIXTURES AND FITTINGS OF 2022 CALIFORNIA
GREEN BUILDING STANDARDS CODE SEE SHEET CG-1.
STANDARDS AND CODESCONSTRUCTION STANDARDS
1. CONTRACTOR TO ENSURE THAT SURFACE TO RECEIVE FINISHES ARE CLEAN,
TRUE AND FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL
UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. COMMENCEMENT
OF WORK SHALL INDICATE INSTALLER'S ACCEPTANCE OF SUBSTRATE.
2. CONTRACTOR TO REPAIR AND PREPARE EXISTING SURFACES SCHEDULED
TO REMAIN AS NECESSARY FOR APPLICATION OF NEW FINISHES.
3. CONTRACTOR SHALL PATCH SURFACES TO MATCH ADJACENT IN A MANNER
SUITABLE TO RECEIVE FINISHES.
4. GYPSUM BOARD CONSTRUCTION SHALL ALIGN WITH EXISTING, ADJACENT, OR
ADJOINING SURFACES, JOINTS SHALL BE TAPED AND SANDED SMOOTH WITH
NO VISIBLE JOINTS, UNLESS OTHERWISE NOTED.
5. CONTRACTOR TO INSURE DELIVERY AND INSTALLATION OF CASEWORK AND
FINISH CARPENTRY WILL NOT BE DAMAGED BY OTHER CONSTRUCTION
WORK.
6. ALL CODE-REQUIRED LABELS SUCH AS "UL", FACTORY MUTUAL OR ANY
EQUIPMENT IDENTIFICATION, PERFORMANCE RATING, NAME OR
NOMENCLATURE PLATES SHALL REMAIN READABLE AND NOT PAINTED.
7. COORDINATE WITH OWNER FOR DELIVERY AND PLACEMENT OF ALL
FURNITURE AND WALL-HUNG EQUIPMENT.
8. REFER TO FINISH SCHEDULE FOR SPECIFIED FINISHES.
REFER TO INTERIOR ELEVATIONS FOR MOUNTING HEIGHT REQUIREMENTS.
9. FOR BUILT-IN WORK SURROUNDED BY PARTITIONS, INCLUDING BUT NOT
LIMITED TO APPLIANCES AND MILLWORK, CONTRACTOR SHALL CONFIRM
THAT FINISHED FLOOR, WALL AND/OR SOFFIT SURFACES DO NOT VARY BY
MORE THAN 1/4" IN 20'-0" (NON-CUMULATIVE). NOTIFY ARCHITECT IF THIS
TOLERANCE IS EXCEEDED.
10. CONTRACTOR SHALL, IN ACCORDANCE WITH THE CONSTRUCTION
DOCUMENTS, APPLY, INSTALL, CONNECT, ERECT, CLEAN, AND/OR CONDITION
MANUFACTURED ARTICLES, MATERIALS AND/OR EQUIPMENT.
11. UNLESS OTHERWISE NOTED, IT IS THE INTENTION OF THE DRAWINGS AND
SPECIFICATIONS FOR ALL WORK, EQUIPMENT, CASEWORK, MECHANICAL,
ELECTRICAL AND SIMILAR DEVICES OF WHATEVER NATURE, BE COMPLETELY
INSTALLED, CONNECTED, MADE OPERATIONAL AND FUNCTIONAL FOR THE
PURPOSE INTENDED, AND THAT ALL COSTS FOR THIS BE INCLUDED IN THE
CONTRACTOR'S PROPOSAL.
12. COORDINATE LOCATION AND PROVIDE BLOCKING, BACKING, AND/OR
REINFORCEMENTS IN PARTITIONS FOR ALL CABINETS, COUNTERTOPS AND
ANY WALL-MOUNTED ITEMS. REFER TO ELEVATIONS AND DETAILS FOR
LOCATIONS OF WALL STANDARDS AND OTHER SUPPORTS.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY FRAMING,
BRACING, AND STRUCTURING ALL WALL, BULKHEAD, AND OTHER DRYWALL
CONSTRUCTION IN ACCORDANCE WITH APPLICABLE TYPICAL DETAILS
CONTAINED IN THE DRAWINGS WHETHER OR NOT SPECIFICALLY
REFERENCED IN THE PLANS OR DETAILS. PROVIDE BLOCKING / BACKING AND
REINFORCEMENT ABOVE AS REQUIRED FOR SUPPORT OF LIGHT FIXTURES,
EQUIPMENT, OR ANY OTHER CEILING-MOUNTED ITEMS.
14. REPAIR AND PATCH ANY/ALL PENETRATIONS THROUGH RATED ASSEMBLIES
TO MAINTAIN REQUIRED RATING.
15. UNLESS OTHERWISE NOTED IN DRAWINGS, FOLLOW ALL MANUFACTURER'S
RECOMMENDATIONS, INSTALLATION INSTRUCTIONS, AND BEST PRACTICES
FOR INSTALLING EQUIPMENT, FURNISHINGS, FITTINGS, ETC. BRING
CONFLICTS BETWEEN DRAWINGS AND MANUFACTURER'S
RECOMMENDATIONS TO THE ATTENTION OF THE ARCHITECT.
GENERAL
A0.01 PROJECT DATA_RESIDENTIAL
ARCHITECTURAL
A1.02 PROPOSED SITE PLAN
A2.01 DEMOLITION & PROPOSED PLANS
A3.00 EXISTING / DEMOLITION EXTERIOR ELEVATIONS
NEIL JOHN
GINTYC-37904
RENEWALDATE
C A L IFORNIAST
A
TEOFLICENSED ARCHIT
E
C
TMAY 31 2027
ATTACHMENT 6Page 220
15'-0" FRONT YARD SETBACK5'-0". SIDE YARD SETBACK
5'-0". SIDE YARD SETBACK5' - 0"13' - 11"12' - 0"11' - 0"4' - 1"5' - 5"10' - 0"31' - 3"
PROPERTY LINE
PROPERTY LINEPROPERTY LINEPROPERTY LINE20'-0" REAR YARD SETBACK4444
440
Sheet Title
Sheet No.
Scale
Drawn By:Checked By:
Job Number:
Issued For
Date:
Job Address
Job Title
Revision No.Date
Written dimensions on these drawings shall have precedence over scaled
dimensions. Drawings shall not be scaled. Contractors shall verify, and be
responsible for, all dimensions and conditions shown by these drawings.
Shop details must be submitted to this office for approval before proceeding
with fabrications. The drawings and their design content are the sole
property of Dwelling Lab, Inc. and may not be reused or reproduced in any
manner without our express written consent.
2'4'8'16'
Agency Approvals t.312.952.9680 | e.design@dwelling-lab.com | w.dwelling-lab.com a. 21 El Caminito, Walnut Creek, CA 94598As indicated
5/30/2025 3:31:12 PMA1.02
PROPOSED SITE PLAN
245 LOS GATOS BLVD, LOS GATOS,
CA 95030
5/7/2025
Project Status
Project Number
245 LOS GATOS BLVD
Author Checker
3/16" = 1'-0"1SITE PLAN_
2ND FLOOR ADDITION560 SF
EXISTING GROUND FLOOR 1,748
EXISTING GARAGE
EXISTING COVERED PORCH
EXISTING PERGOLA
LOS GATOS BLVD
NEIL JOHN
GINTYC-37904
RENEWALDATE
C A L IFORNIAST
A
TEOFLICENSED ARCHIT
E
C
TMAY 31 2027
Page 221
W/D W/D
Refrig.
UP
W/D W/D
UP
UP
UP
Refrig.
W/D
(E) WALL TO BE REMOVED
(E) WALL TO REMAIN
(E) DOOR TO BE REMOVED
LEGEND -DEMOLITION
(E) AREA TO BE REMOVED (E) WINDOW TO BE REMOVED
(E) WINDOW TO REMAIN
(E) DOOR TO REMAIN
(E) ITEM TO BE REMOVED
1. GENERAL CONTRACTOR TO NOTIFY ARCHITECT
OF ANY DISCOVERY OF UNFORSEEN CONDITIONS
IN THE PROCESS OF DEMOLITION
2. (E) STRUCTURAL BEARING ELEMENTS TO REMAIN
U.O.N. GENERAL CONTRACTOR TO NOTIFY
ARCHITECT IF ANY BEARING COLUMNS ARE
FOUND IN PARTITIONS TO BE REMOVED THAT DO
NOT APPEAR IN PLANS.
3. DAMAGES WHICH OCCUR DURING DEMOLITION
AND/OR CONSTRUCTION SHALL BE THE GENERAL
CONTRACTOR'S RESPONSIBILITY AND EXPENSE
TO RESTORE/REPAIR TO ORIGINAL CONDITION.
4. IF ANY MATERIALS SUSPECTED OF CONTAINING
ASBESTOS OR ANY OTHER HAZARDOUS
MATERIALS ARE ENCOUNTERED, DO NOT
DISTURB THE MATERIALS. IMMEDIATELY NOTIFY
THE OWNER, OWNER'S
REP/LANDLORD/TENANT/CLIENT AND ARCHITECT.
DEMOLITION NOTES
32' - 1"15' - 6"15' - 4 1/8"14' - 5"
10' - 5"3' - 8"4' - 9 1/8"4' - 9 1/8"9' - 11"12' - 8"11' - 10"3' - 6"13' - 4"19' - 4"9' - 10"8' - 9"16' - 10"2' - 3 7/8"3' - 5"1' - 7 5/8"4' - 2 13/16"
1' - 0"1' - 0"
40' - 10"20' - 1 7/8"7' - 10 1/8"13' - 9 1/8"44' - 8 7/8"15' - 4 1/2"A3.00
A3.00
A3.001A3.00
5
7
3
11
A3.00
BEDROOM
LIVING ROOM
BEDROOM
MEDIA ROOM
BATH
WIC
BATH
30' - 10"32' - 1"40' - 10"20' - 2"44' - 1"15' - 4"COVERED PORCH
1. DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED :
A) TO FACE OF FINISH
B) TO CENTER OF DOORS AND OTHER OPENINGS
C) TO TOP OF FINISHED FLOORS
D) TO BOTTOM OF FINISH AT CEILINGS
E) TO OUTSIDE FACE OF FINISHED MILLWORK
F) TO FINISHED WINDOW FRAME. SEE WINDOW DETAILS.
2. DIMENSIONS SHOWN AS V.I.F. SHALL BE VERIFIED BY THE CONTRACTOR
IN THE FIELD. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES IN DIMENSIONS PRIOR TO PROCEEDING WITH THE
WORK IN THAT AREA.
3. DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW
FOR THICKNESS OF FINISHES INCLUDING CERAMIC TILE, VCT, ETC.
DIMENSIONS MARKED "CLEAR" ARE TO BE WITHIN 1/8" OF GIVEN
DIMENSION ALONG FULL HEIGHT/WIDTH/LENGTH OF SURFACES.
4. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN PARTITION
LOCATIONS, DIMENSIONS AND TYPES. DOOR AND WINDOW LOCATIONS
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
NOTIFY ARCHITECT FOR WRITTEN CLARIFICATION PRIOR TO
PROCEEDING WITH CONSTRUCTION. CONSTRUCTION PLAN BY
ARCHITECT SUPERSEDES OTHER PLANS.
5. ANY GRAPHICAL ERRORS, APPARENT OR ASSUMED, SHOULD BE
CLARIFIED WITH AN RFI PRIOR TO CONSTRUCTION
DIMENSION NOTES
1. REPLACEMENT OF GYPBOARD MUST BE 5/8" TYPE X WITH 5D
COOLER NAILS AT 4 INCHES ON CENTER OR EQUIVALENT SCREWS
FOR ALL INTERIOR NON-STRUCTURAL ALTERATIONS.
2. REFER TO BUILDING CODE ANALYSIS FOR LOCATIONS OF FIRE
RESISTANCE RATED WALLS.
3. THERMAL INSULATION TO BE PROVIDED BETWEEN CONDITIONED
AND NONCONDITIONED SPACES TYP. REFER TO ASSEMBLY TYPES.
4. ACOUSTIC INSULATION TO BE PROVIDED IN ALL WALLS
SURROUNDING BATHROOM AND LAUNDRY AREAS (INCLUDES
MUDROOM AND BASEMENT STORAGE). REFER TO ASSEMBLY
TYPES.
5. PROVIDE (N) LEVELING SUBSTRATE o/ EXISTING/NEW SUBFLOOR
ASSEMBLY THROUGHOUT AS REQUIRED TO ACHIEVE SMOOTH
CONTIGUOUS, LEVEL (N) FINISH FLOORING; TYP.
6. ALL GUARDRAIL & HANDRAIL CONSTRUCTION SHALL WITHSTAND A
200 LB. CONCENTRATED LOAD AND 50 LB./ FT. UNIFORM LOAD
APPLIED LATERALLY AND VERTICALLY AT THE HIGHEST POINT OF
THE RAIL--WHICHEVER IS GREATER. (TYP. ALL GUARDRAILS) AS
SPECIFIED IN CBC SECTION 1607.8., S.S.D.
PROPOSED PLAN GENERAL NOTES LEGEND -NEW CONSTRUCTION
##
(E) WALL TO REMAIN
(N) WALL
ABOVE OR BELOW (N) WINDOW
[N.I.C.] NOT IN CONTRACT
1 HR. FIRE RESISTANCE
RATED WALL
(N) DOOR
(E) WINDOW TO REMAIN
XXX
(N) BEARING WALL
(N) FOOTING
HEADER OR BEAM
(N) BRACE WALL PANEL
11
A3.00
17' - 8"
ATTIC
OVER
EXISTING
HOUSE
ATTIC
ACCESS
BEDROOM
WIC
BATH
BEDROOM
BATH18' - 10"12' - 0"22' - 11"
5' - 3"
0
Sheet Title
Sheet No.
Scale
Drawn By:Checked By:
Job Number:
Issued For
Date:
Job Address
Job Title
Revision No.Date
Written dimensions on these drawings shall have precedence over scaled
dimensions. Drawings shall not be scaled. Contractors shall verify, and be
responsible for, all dimensions and conditions shown by these drawings.
Shop details must be submitted to this office for approval before proceeding
with fabrications. The drawings and their design content are the sole
property of Dwelling Lab, Inc. and may not be reused or reproduced in any
manner without our express written consent.
2'4'8'16'
Agency Approvals t.312.952.9680 | e.design@dwelling-lab.com | w.dwelling-lab.com a. 21 El Caminito, Walnut Creek, CA 94598As indicated
5/30/2025 3:31:13 PMA2.01
DEMOLITION &
PROPOSED PLANS
245 LOS GATOS BLVD, LOS GATOS,
CA 95030
5/7/2025
Project Status
Project Number
245 LOS GATOS BLVD
Author Checker
3/16" = 1'-0"4DEMOLITION FLOOR PLAN -FIRST FLOOR
3/16" = 1'-0"1FLOOR PLAN -FIRST FLOOR
3/16" = 1'-0"2FLOOR PLAN -SECOND FLOOR
NEIL JOHN
GINTYC-37904
RENEWALDATE
C A L IFORNIAST
A
TEOFLICENSED ARCHIT
E
C
TMAY 31 2027
Page 222
(E) ITEM TO BE REMOVED
LEGEND -DEMOLITION
(E) AREA TO BE REMOVED
(E) WALL TO REMAIN
(E) WALL TO REMAIN
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"24' - 1"1. 0'-0" (E) FINISH FLOOR LEVEL AT 1ST FLOOR IS DETERMINED BY ELEVATION
MARK.
PROPOSED ELEVATIONS GENERAL NOTES
1. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFO.
2. 0'-0" (E) FINISH FLOOR LEVEL AT 1ST FLOOR IS DETERMINED BY ELEVATION
MARK
3. ACOUSTIC INSULATION TO BE PROVIDED IN ALL WALL, FLOOR, AND CEILING
ASSEMBLIES SURROUNDING BATHROOM AND LAUNDRY AREAS.
BUILDING SECTIONS GENERAL NOTES
1. DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED :
A) TO FACE OF FINISH
B) TO CENTER OF DOORS AND OTHER OPENINGS
C) TO TOP OF FINISHED FLOORS
D) TO BOTTOM OF FINISH AT CEILINGS
E) TO OUTSIDE FACE OF FINISHED MILLWORK
F) TO FINISHED WINDOW FRAME. SEE WINDOW DETAILS.
2. DIMENSIONS SHOWN AS V.I.F. SHALL BE VERIFIED BY THE CONTRACTOR
IN THE FIELD. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES IN DIMENSIONS PRIOR TO PROCEEDING WITH THE
WORK IN THAT AREA.
3. DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW
FOR THICKNESS OF FINISHES INCLUDING CERAMIC TILE, VCT, ETC.
DIMENSIONS MARKED "CLEAR" ARE TO BE WITHIN 1/8" OF GIVEN
DIMENSION ALONG FULL HEIGHT/WIDTH/LENGTH OF SURFACES.
4. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN PARTITION
LOCATIONS, DIMENSIONS AND TYPES. DOOR AND WINDOW LOCATIONS
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
NOTIFY ARCHITECT FOR WRITTEN CLARIFICATION PRIOR TO
PROCEEDING WITH CONSTRUCTION. CONSTRUCTION PLAN BY
ARCHITECT SUPERSEDES OTHER PLANS.
5. ANY GRAPHICAL ERRORS, APPARENT OR ASSUMED, SHOULD BE
CLARIFIED WITH AN RFI PRIOR TO CONSTRUCTION
DIMENSION NOTES LEGEND -NEW CONSTRUCTION
(E) WALL TO REMAIN
(N) WALL
ABOVE OR BELOW
[N.I.C.] NOT IN CONTRACT
1 HR. FIRE RESISTANCE
RATED WALL
0
Sheet Title
Sheet No.
Scale
Drawn By:Checked By:
Job Number:
Issued For
Date:
Job Address
Job Title
Revision No.Date
Written dimensions on these drawings shall have precedence over scaled
dimensions. Drawings shall not be scaled. Contractors shall verify, and be
responsible for, all dimensions and conditions shown by these drawings.
Shop details must be submitted to this office for approval before proceeding
with fabrications. The drawings and their design content are the sole
property of Dwelling Lab, Inc. and may not be reused or reproduced in any
manner without our express written consent.
2'4'8'16'
Agency Approvals t.312.952.9680 | e.design@dwelling-lab.com | w.dwelling-lab.com a. 21 El Caminito, Walnut Creek, CA 94598As indicated
5/30/2025 3:31:15 PMA3.00
EXISTING / DEMOLITION
EXTERIOR ELEVATIONS
245 LOS GATOS BLVD, LOS GATOS,
CA 95030
5/7/2025
Project Status
Project Number
245 LOS GATOS BLVD
Author Checker
1/8" = 1'-0"2EXISTING ELEVATION -EAST
1/8" = 1'-0"8EXISTING ELEVATION -NORTH
1/8" = 1'-0"4EXISTING ELEVATION -WEST
1/8" = 1'-0"6EXISTING ELEVATION -SOUTH
1/8" = 1'-0"1PROPOSED ELEVATION -EAST
1/8" = 1'-0"7PROPOSED ELEVATION -NORTH
1/8" = 1'-0"5PROPOSED ELEVATION -SOUTH
1/8" = 1'-0"3PROPOSED ELEVATION -WEST
1/8" = 1'-0"11Section 3
CLAY TILE ROOF
CLAY TILE ROOF
(E) CLAY TILE ROOF
CLAY TILE ROOF
(E) CLAY TILE ROOF
CLAY TILE ROOF
(E) ROOF
STUCCO (WHITE)
STUCCO WHITE
STUCCO WHITE
STUCCO WHITE
CLAY TILE ROOF
NEW PROPOSED HEIGHT
Spanish / Mission Revival
ARCHITECTURAL STYLE BASED ON THE LOS GATOSRESIDENTIAL DESIGN GUIDELINES
1- SHAPED ROOF PARAPET 2- OVERHANGING EAVES 3- RED CLAY ROOF TILES 4- ARCHED DOOR WAYS
NEIL JOHN
GINTYC-37904
RENEWALDATE
C A L IFORNIAST
A
TEOFLICENSED ARCHIT
E
C
TMAY 31 2027
Page 223
Residential Design Guidelines 33
Town of Los Gatos BUILDING DESIGN3
3.8.3 Use traditional detailing
•Treat openings in walls as though they were constructed of
the traditional material for the style. For example, be sure to
provide substantial wall space above arches in stucco and
stone walls. Traditionally, wall space above the arch would
have been necessary to structurally span the opening, and
to make the space too small is inconsistent with the archi-
tectural style.
•Openings in walls faced with stone, real or synthetic, should
have defined lintels above the opening except in Mission or
Spanish Eclectic styles. Lintels may be stone, brick or wood
as suits the style of the house.
•Treat synthetic materials as though they were authentic.
For example, select synthetic stone patterns that place the
individual stones in a horizontal plane as they would have
been in a load bearing masonry wall.
•Select roof materials that are consistent with the traditional
architectural style (e.g., avoid concrete roof tiles on a Crafts-
man Style house.)
3.8.4 Materials changes
•Make materials and color changes at inside corners rather
than outside corners to avoid a pasted on look.
3.9 ADDITIONS/ACCESSORY BUILDINGS/SECONDARY
UNITS
•Site additions in the least conspicuous place. In many cases
this is a rear or side elevation - only rarely is it a rooftop.
•The existing built forms, components and materials should
be reinforced. Heights and proportions of additions and
alterations should be consistent with and continue the
original architectural style and design.
•Additions should be subordinate, and compatible in scale
and proportion to the historically significant portions of
the existing structure.
•When an addition or remodel requires the use of newly
constructed exterior elements, they should be identical in
size, dimension, shape and location as the original, and
Use stone or wood lintels over
openings in stone walls
Additions, accessory buildings and secondary
units should match the form, architectural
style, and details of the original house
ATTACHMENT 7
Page 224
Residential Design Guidelines34
Town of Los Gatos
BUILDING DESIGN3
should utilize the same materials as the existing protected
exterior elements.
•When an addition necessitates the removal of architectural
materials, such as siding, windows, doors, and decorative
elements, they should be carefully removed and reused in
the addition where possible.
•The introduction of window and door openings not char-
acteristic in proportion, scale, or style with the original
architecture is strongly discouraged (e.g., sliding windows or
doors in a structure characterized by double hung windows
and swinging doors).
•The character of any addition or alteration should be in
keeping with and subordinate to the integrity of the original
structure.
•The amount of foundation exposed on the addition should
match that of the original building.
•Do not add roof top additions where the roof is of historic
significance.
•Second floor additions are discouraged in neighborhoods
with largely one story homes. If horizontal expansion of
the house is not possible, consider incorporating a second
floor addition within the roof form as shown in the example
to the left.
•Second floor additions which are not embedded within the
roof form should be located to the rear of the structure.
•The height and proportion of an addition or a second story
should not dominate the original structure.
•Deck additions should be placed to the rear of the struc-
ture only, and should be subordinate in terms of scale and
detailing.
•New outbuildings, such as garages, should be clearly subor-
dinate to the main structure in massing, and should utilize
forms, materials and details which are similar to the main
structure.
•Garages should generally be located to the rear of the lot
behind the rear wall of the residence. One car wide access
driveways should be utilized.
Original structure
Addition incorporated into the roof
successfully adds space while respecting the
integrity of the existing house and the scale of
the neighborhood
Placing a two story addition to the rear can minimize its impact on the historic resource and the scale of the neighborhood
Page 225
This Page
Intentionally
Left Blank
Page 226
dwelling labdesign@dwelling-lab.comdwelling-lab.com(312) 952-9680
w. dwelling-lab.com | e. design@dwelling-lab.com | p. 312.952.9680 | a. 21 El Caminito, Walnut Creek, CA 94598
Sincerely,
Neil Ginty
Founder & Principal Architect
M.A., B.Arch, NCARB, Registered Architect
July 28, 2025
Historic Preservation CommitteeTown of Los Gatos 110 E. Main Street
Los Gatos, CA 95030
RE: Response to Comments on Second Story Addition Proposal – 245 LosGatos Blvd.
Dear Members of the Historic Preservation Committee,
Thank you for your thoughtful review of our proposed second-story addition and foryour comments regarding ways to improve its integration with the existingresidence.
We appreciate your suggestion to move the second-story addition forward tocreate a more cohesive relationship with the original structure. We have revisitedour design with this in mind and are exploring adjustments that will bring theaddition forward in a manner that maintains the integrity of the existing façade
while enhancing the architectural unity of the home.
Additionally, we recognize the importance of maintaining and reinforcing theSpanish/Mission Revival character of the property. In response to yourrecommendation, we are incorporating additional stylistic embellishments and
details consistent with this architectural language. These include enhanced
roofline articulation,tile vents, colonial style windows, decorative ironwork such aslanterns, and appropriate stucco textures and finishes.
We are committed to ensuring that the final design aligns with both the historic
context of the neighborhood and the guiding principles of the Committee. We look
forward to presenting the revised plans for your review and welcome any furtherinput you may have.
Thank you again for your guidance and dedication to preserving the character of
our community.
EXHIBIT 2
Page 227
This Page
Intentionally
Left Blank
Page 228
ABBREVIATIONS
&AND
@ AT
A.B.ANCHOR BOLT
A.C.AIR CONDITIONING
ACOUST. ACOUSTICAL
A.C.T. ACOUSTICAL CEILING TILE
A.D.AREA DRAIN
A.F.F. ABOVE FINISHED FLOOR
ALUM. ALUMINUM
ARCH. ARCHITECT OR ARCHITECTURAL
BLKG. BLOCKING
B.P.BUILDING PAPER
B.O.BOTTOM OF
CAB.CABINET
CATV CABLE TELEVISION
C.C.CENTER TO CENTER
C.I.P.CAST-IN-PLACE
C.J.CONTROL JOINT
C.L.CENTER LINE
CLG.CEILING
CLR.CLEAR
C.O.CLEAN OUT
CONC. CONCRETE
DEMO. DEMOLITION OR DEMOLISH
DEPT. DEPARTMENT
DIA.DIAMETER
DIM.DIMENSION
D.W.DISHWASHER
DWG(S). DRAWING(S)
(E)EXISTING
EA.EACH
E.B.EXPANSION BOLT
ELEC. ELECTRICAL
ELEV. ELEVATION
E.O.S. EDGE OF SLAB
EQ.EQUAL
SPEC. SPECIFICATION (S)
SQ.SQUARE
S.T.C. SOUND TRANSMISSION COEFFICIENT
STD.STANDARD(S)
STL.STEEL
TB.TOWEL BAR
T.B.D. TO BE DETERMINED
T & G TONGUE AND GROOVE
THR.THRESHOLD
T.O.TOP OF
T.O.B. TOP OF BEAM
T.O.P. TOP OF PAVING
T.O.S. TOP OF SLAB
T.O.STL. TOP OF STEEL
T.V.TELEVISION
TYP.TYPICAL
V.B.VAPOR BARRIER
VERT. VERTICAL
V.I.F.VERIFY IN FIELD
W/WITH
W.C.WATER CLOSET
WD.WOOD
W/D WASHER/DRYER
WH.WATER HEATER
W/O WITHOUT
WP.WATERPROOF / WEATHERPROOF
WT.WEIGHT
YD.YARD
H.B.HOSE BIB
H.D.HOLD DOWN
HT.HEIGHT
HTG.HEATING
HVAC HEATING, VENTILATION & AIR CONDITIONING
H.W.HOT WATER
IN.INCH(ES)
LAV.LAVATORY
LBS.POUNDS
L.F.LINEAR FOOT
L.V.T. LUXURY VINYL TILE
F.A.U. FORCED AIR UNIT
F.C.U. FAN COIL UNIT
F.D.FLOOR DRAIN
F.F.FINISH FLOOR
FIN.FINISH OR FINISHED
FLR.FLOOR
FT.FOOT / FEET
FTG.FOOTING
G.GAS
GA.GAUGE
G.C.GENERAL CONTRATOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
G.L.GRIDLINE
G.W.B. GYPSUM WALL BOARD
GYP.GYPSUM
MACH. MACHINE
MANUF. MANUFACTURER
MAX. MAXIMUM
M.B.MACHINE BOLT
MDF MEDIUM DENSITY FIBERBOARD
M.E.P. MECHANICAL/ELECTRICAL/PLUMBING
MEMB. MEMBRANE
MIN.MINIMUM
MIR.MIRROR
MISC. MISCELLANEOUS
MTL.METAL
MW.MICROWAVE
(N)NEW
N/A NOT APPLICABLE
O/OVER
O.C.ON CENTER
PLYWD. PLYWOOD
PLUMB. PLUMBING
P.S.F. POUNDS PER SQUARE FOOT
P.S.I.POUNDS PER SQUARE INCH
P.T.PRESSURE TREATED
P.V.C. POLY VINYL CHLORIDE PIPE
R.C.P. REFLECTED CEILING PLAN
REQ'D REQUIRED
RET.RETAIN / RETAINING
REV.REVISION
S.C.SOLID CORE
SIM.SIMILAR
DRAWING INDEXSYMBOLS
ROOM NAME
101
Name
Elevation
1
1
A101
A
A
A
A
A101
1
1
A1.01
88
1
A1.01
ROOM NAME & NUMBER
WINDOW NUMBER
DOOR NUMBER
ELEV. HT. REFERENCE
NORTH ARROW
MATERIAL TAG
REVISION
INTERIOR ELEVATION
DETAIL REFERENCE
ELEVATION REFERENCE
SECTION REFERENCE
ASSEMBLY TYPE REFERENCE
DETAIL CALLOUT
PROJECT NORTH
TRUE NORTH
999
A101
1 SIM
XX-00
ROOM NUMBER
DOOR NUMBER (SEQUENTIAL)
SITE INFORMATION
ADDRESS:245 LOS GATOS BLVD, LOS GATOS, CA 95030
APN:529 24 024
CLIMATE ZONE:3
SEISMIC DESIGN CATEGORY: (D0, D1, D2)
SCOPE OF WORK:
1ST FLOOR
REMODEL OF EXISTING SINGLE FAMILY DWELLING INCLUDING BATHROOM, KITCHEN,
AND ASSOCIATE PLUMBING AND ELECTRICAL WORKS.
2ND FLOOR
ADDITION TO EXISTING SINGLE FAMILY DWELLING INCLUDING TWO NEW BATHS AND
TWO BEDROOMS WITH A LAUNDRY CLOSET.
PROJECT DATA
ZONING DATA
YEAR BUILT:1924
ASSESSOR'S PARCEL NUMBER (BLOCK/LOT): 24
PLANNING DISTRICT:
NEIGHBORHOOD (PLANNING):
ZONE:R1-D
HEIGHT & BULK:
APPLICABLE CODES:
2022 CALIFORNIA BUILDING CODE
2022 CALIFORNIA RESIDENTIAL CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA FIRE CODE
NATIONAL FIRE PROTECTION ASSOCIATION (BOOKLET 101)
CALIFORNIA ENERGY COMMISSION TITLE 24
2022 CALIFORNIA GREEN BUILDINGS STANDARDS CODE
ALL OTHER APPLICABLE CITY AND COUNTY LAWS AND ORDINANCES
PARCEL AREA CALCULATIONS
PARCEL AREA:7,000 SQ.FT (0.16 ACRES)
GROSS FLOOR AREA:
FIRST FLOOR 1,748 SF
SECOND FLOOR 560 SF
TOTAL FLOOR AREA 2,308 SF
ALLOWABLE F.A.R. .35 - (7,000-5/25 X.20) = .33
PROPOSED F.A.R..33 X 7,000 = 2,310
MAX ROOF HEIGHT 30'-0"
PROPOSED HEIGHT 24'-7"
BUILDING DATA
OCCUPANCY:R-3 (SINGLE FAMILY DWELLING)
CONSTRUCTION TYPE:V-B
FIRE SPRINKLERS:NO
(E) SQ. FT.:1,748 SF
PROPOSED SQ. FT.:2,308 SF
VICINITY MAP
PROJECT
LOCATION
ARCHITECT:
DWELLING LAB
NEIL GINTY
21 EL CAMINITO
WALNUT CREEK, CA 94598
CONTACT:
PHONE:(312) 952-9680
EMAIL:design@dwelling-lab.com
WEBSITE dwelling-lab.com
OWNERS:
MONIQUE PHAM
CONTACT:
PHONE:
STRUCTURAL ENGINEER:
XXX
CONTACT:
PHONE:
PROJECT DIRECTORY
NEIL JOHN
GINTY
C-37904
RENEWAL
DATE
C A L IF O RNIASTAT
E
OFLICENSED ARCHIT
E
CTMAY 31 2027
0
Sheet Title
Sheet No.
Scale
Drawn By:Checked By:
Job Number:
Issued For
Date:
Job Address
Job Title
Revision No.Date
Written dimensions on these drawings shall have precedence over scaled
dimensions. Drawings shall not be scaled. Contractors shall verify, and be
responsible for, all dimensions and conditions shown by these drawings.
Shop details must be submitted to this office for approval before proceeding
with fabrications. The drawings and their design content are the sole
property of Dwelling Lab, Inc. and may not be reused or reproduced in any
manner without our express written consent.
2'4'8'16'
Agency Approvals t.312.952.9680 | e.design@dwelling-lab.com | w.dwelling-lab.coma. 21 El Caminito, Walnut Creek, CA 94598As indicated
7/28/2025 4:24:09 PMA0.01
PROJECT
DATA_RESIDENTIAL
245 LOS GATOS BLVD, LOS GATOS,
CA 95030
5/7/2025
Project Status
Project Number
245 LOS GATOS BLVD
Author Checker
EXISTING PHOTOGRAPH
GENERAL
A0.01 PROJECT DATA_RESIDENTIAL
ARCHITECTURAL
A1.02 PROPOSED SITE PLAN
A2.01 DEMOLITION & PROPOSED PLANS
A3.00 EXISTING / DEMOLITION EXTERIOR ELEVATIONS
GENERAL NOTES
1. CONTRACTOR IS HEREBY SPECIFICALLY DIRECTED AS A CONDITION OF THE
CONTRACT TO ACQUAINT HIMSELF/HERSELF WITH THE ARTICLES CONTAINED
IN THE GENERAL NOTES AND TO NOTIFY AND APPRISE ALL SUBCONTRACTORS
AND ALL OTHER PARTIES OF THE CONTRACT OF, AND BIND THEM TO, ITS
CONDITIONS.
2. DRAWINGS OF BASE BUILDING CONDITIONS ARE GENERATED FROM AS-BUILT
DRAWINGS AND LIMITED FIELD OBSERVATION BY THE ARCHITECT. ACTUAL
CONDITIONS MAY DIFFER FROM THOSE SHOWN.
3. CONTRACTOR SHALL FILE, OBTAIN AND PAY FEES FOR BUILDING
DEPARTMENT AND ALL OTHER AGENCY APPROVALS AND PERMITS,
CONTROLLED INSPECTIONS, AND FINAL SIGN-OFFS FOR PROJECT
COMPLETION. COPIES OF TRANSACTIONS SHALL BE FORWARDED TO THE
OWNER PRIOR TO COMMENCING WORK.
4. CONTRACTOR SHALL VERIFY THAT DRAWINGS ARE THE LATEST ISSUANCE
PRIOR TO BEGINNING OF CONSTRUCTION.
5. CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OUTSIDE
VENDORS INCLUDING, BUT NOT LIMITED TO, TELEPHONE, DATA AND "OWNER'S
FORCES". CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL
DO THE CUTTING, FITTING AND PATCHING REQUIRED TO RECEIVE THE WORK
OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND
SPECIFICATIONS.
6. ALL IDENTIFIED SCOPE OF WORK SHALL BE PROVIDED NEW, UNLESS
OTHERWISE NOTED.
7. WORK NOT SPECIFICALLY DETAILED, NOTED OR SPECIFIED, SHALL BE THE
SAME AS SIMILAR PARTS THAT ARE DETAILED, NOTED OR SPECIFIED.
8. IN THE EVENT OF INCONSISTENCIES AMONG THE CONTRACT DOCUMENTS,
THE ARCHITECT SHALL INTERPRET THEM WHEN ASKED TO DO SO BY THE
OWNER OR CONTRACTOR. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR
THE RESULTS OF SUCH INTERPRETATIONS MADE BY OTHERS.
9. THE GENERAL CHARACTER OF DETAIL WORK IS SHOWN ON THE CONTRACT
DOCUMENTS. SUBSEQUENT CLARIFICATIONS MAY BE MADE BY ADDITIONAL
LAYOUTS OR LARGE SCALE OR FULL SIZE DETAILS.
10. VERIFY ALL EQUIPMENT SIZES BEFORE BEGINNING WORK
11. "TYPICAL" OR "TYP." SHALL MEAN THAT THE CONDITION IS REPRESENTATIVE
FOR SIMILAR CONDITIONS THROUGHOUT, UNLESS OTHERWISE NOTED.
DETAILS OR DIMENSIONS ARE USUALLY KEYED, AND NOTED "TYP" ONLY WHEN
THEY FIRST OCCUR.
12. "SIMILAR" OR "SIM." MEANS COMPARABLE CHARACTERISTICS FOR THE
CONDITIONS NOTED. VERIFY DIMENSIONS, ORIENTATION, AND CONDITIONS ON
PLANS AND ELEVATIONS
13. ARCHITECT SHALL HAVE THE AUTHORITY TO REJECT ANY WORK THAT IS NOT
IN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS
1. REFER TO TITLE SHEET FOR APPLICABLE CODES
2. GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, CODES,
RULES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK. IF THE
CONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT
VARIANCE THEREWITH, PROMPTLY NOTIFY THE PROJECT MANAGER AND/OR
ARCHITECT. NECESSARY CHANGES SHALL BE MADE IN ACCORDANCE WITH
THE GENERAL CONDITIONS.
3. IF CONTRACTOR KNOWINGLY PERFORMS ANY WORK WHICH IS CONTRARY TO
SUCH LAWS, ORDINANCES, CODES, RULES AND REGULATIONS, HE/SHE SHALL
PROMPTLY MAKE ALL CHANGES AS REQUIRED TO COMPLY THEREWITH AND
BEAR ALL COSTS ARISING THEREFROM.
4. CONFLICTS: IN CASE OF CONFLICTS IN THE REQUIREMENTS OF AUTHORITIES
HAVING JURISDICTION, THE MOST RESTRICTIVE REQUIREMENTS SHALL
GOVERN.
5. WHERE CODES OR REGULATIONS, OTHER THAN THOSE LISTED IN THIS
SECTION, ARE REFERRED TO IN VARIOUS SECTIONS OF THE SPECIFICATIONS.
IT SHALL BE UNDERSTOOD THAT THEY APPLY TO THIS WORK AS FULLY AS IF
CITED HEREIN.
6. ALL COMBUSTIBLE MATERIALS SHALL MEET APPLICABLE CODES. WOOD
SHALL BE FIRE RETARDANT TREATED WHERE REQUIRED BY LOCAL BUILDING
CODES AND BUILDING OWNER'S REQUIREMENT'S.
7. FOR MAXIMUM FLOW RATES FOR PLUMBING FIXTURES, REFER TO
STANDARDS FOR PLUMBING FIXTURES AND FITTINGS OF 2022 CALIFORNIA
GREEN BUILDING STANDARDS CODE SEE SHEET CG-1.
STANDARDS AND CODESCONSTRUCTION STANDARDS
1. CONTRACTOR TO ENSURE THAT SURFACE TO RECEIVE FINISHES ARE CLEAN,
TRUE AND FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL
UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. COMMENCEMENT
OF WORK SHALL INDICATE INSTALLER'S ACCEPTANCE OF SUBSTRATE.
2. CONTRACTOR TO REPAIR AND PREPARE EXISTING SURFACES SCHEDULED
TO REMAIN AS NECESSARY FOR APPLICATION OF NEW FINISHES.
3. CONTRACTOR SHALL PATCH SURFACES TO MATCH ADJACENT IN A MANNER
SUITABLE TO RECEIVE FINISHES.
4. GYPSUM BOARD CONSTRUCTION SHALL ALIGN WITH EXISTING, ADJACENT, OR
ADJOINING SURFACES, JOINTS SHALL BE TAPED AND SANDED SMOOTH WITH
NO VISIBLE JOINTS, UNLESS OTHERWISE NOTED.
5. CONTRACTOR TO INSURE DELIVERY AND INSTALLATION OF CASEWORK AND
FINISH CARPENTRY WILL NOT BE DAMAGED BY OTHER CONSTRUCTION
WORK.
6. ALL CODE-REQUIRED LABELS SUCH AS "UL", FACTORY MUTUAL OR ANY
EQUIPMENT IDENTIFICATION, PERFORMANCE RATING, NAME OR
NOMENCLATURE PLATES SHALL REMAIN READABLE AND NOT PAINTED.
7. COORDINATE WITH OWNER FOR DELIVERY AND PLACEMENT OF ALL
FURNITURE AND WALL-HUNG EQUIPMENT.
8. REFER TO FINISH SCHEDULE FOR SPECIFIED FINISHES.
REFER TO INTERIOR ELEVATIONS FOR MOUNTING HEIGHT REQUIREMENTS.
9. FOR BUILT-IN WORK SURROUNDED BY PARTITIONS, INCLUDING BUT NOT
LIMITED TO APPLIANCES AND MILLWORK, CONTRACTOR SHALL CONFIRM
THAT FINISHED FLOOR, WALL AND/OR SOFFIT SURFACES DO NOT VARY BY
MORE THAN 1/4" IN 20'-0" (NON-CUMULATIVE). NOTIFY ARCHITECT IF THIS
TOLERANCE IS EXCEEDED.
10. CONTRACTOR SHALL, IN ACCORDANCE WITH THE CONSTRUCTION
DOCUMENTS, APPLY, INSTALL, CONNECT, ERECT, CLEAN, AND/OR CONDITION
MANUFACTURED ARTICLES, MATERIALS AND/OR EQUIPMENT.
11. UNLESS OTHERWISE NOTED, IT IS THE INTENTION OF THE DRAWINGS AND
SPECIFICATIONS FOR ALL WORK, EQUIPMENT, CASEWORK, MECHANICAL,
ELECTRICAL AND SIMILAR DEVICES OF WHATEVER NATURE, BE COMPLETELY
INSTALLED, CONNECTED, MADE OPERATIONAL AND FUNCTIONAL FOR THE
PURPOSE INTENDED, AND THAT ALL COSTS FOR THIS BE INCLUDED IN THE
CONTRACTOR'S PROPOSAL.
12. COORDINATE LOCATION AND PROVIDE BLOCKING, BACKING, AND/OR
REINFORCEMENTS IN PARTITIONS FOR ALL CABINETS, COUNTERTOPS AND
ANY WALL-MOUNTED ITEMS. REFER TO ELEVATIONS AND DETAILS FOR
LOCATIONS OF WALL STANDARDS AND OTHER SUPPORTS.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY FRAMING,
BRACING, AND STRUCTURING ALL WALL, BULKHEAD, AND OTHER DRYWALL
CONSTRUCTION IN ACCORDANCE WITH APPLICABLE TYPICAL DETAILS
CONTAINED IN THE DRAWINGS WHETHER OR NOT SPECIFICALLY
REFERENCED IN THE PLANS OR DETAILS. PROVIDE BLOCKING / BACKING AND
REINFORCEMENT ABOVE AS REQUIRED FOR SUPPORT OF LIGHT FIXTURES,
EQUIPMENT, OR ANY OTHER CEILING-MOUNTED ITEMS.
14. REPAIR AND PATCH ANY/ALL PENETRATIONS THROUGH RATED ASSEMBLIES
TO MAINTAIN REQUIRED RATING.
15. UNLESS OTHERWISE NOTED IN DRAWINGS, FOLLOW ALL MANUFACTURER'S
RECOMMENDATIONS, INSTALLATION INSTRUCTIONS, AND BEST PRACTICES
FOR INSTALLING EQUIPMENT, FURNISHINGS, FITTINGS, ETC. BRING
CONFLICTS BETWEEN DRAWINGS AND MANUFACTURER'S
RECOMMENDATIONS TO THE ATTENTION OF THE ARCHITECT.
07/28/2025
EXHIBIT 3
Page 229
1. DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED :
A) TO FACE OF FINISH
B) TO CENTER OF DOORS AND OTHER OPENINGS
C) TO TOP OF FINISHED FLOORS
D) TO BOTTOM OF FINISH AT CEILINGS
E) TO OUTSIDE FACE OF FINISHED MILLWORK
F) TO FINISHED WINDOW FRAME. SEE WINDOW DETAILS.
2. DIMENSIONS SHOWN AS V.I.F. SHALL BE VERIFIED BY THE CONTRACTOR
IN THE FIELD. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES IN DIMENSIONS PRIOR TO PROCEEDING WITH THE
WORK IN THAT AREA.
3. DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW
FOR THICKNESS OF FINISHES INCLUDING CERAMIC TILE, VCT, ETC.
DIMENSIONS MARKED "CLEAR" ARE TO BE WITHIN 1/8" OF GIVEN
DIMENSION ALONG FULL HEIGHT/WIDTH/LENGTH OF SURFACES.
4. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN PARTITION
LOCATIONS, DIMENSIONS AND TYPES. DOOR AND WINDOW LOCATIONS
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
NOTIFY ARCHITECT FOR WRITTEN CLARIFICATION PRIOR TO
PROCEEDING WITH CONSTRUCTION. CONSTRUCTION PLAN BY
ARCHITECT SUPERSEDES OTHER PLANS.
5. ANY GRAPHICAL ERRORS, APPARENT OR ASSUMED, SHOULD BE
CLARIFIED WITH AN RFI PRIOR TO CONSTRUCTION
DIMENSION NOTES
1. LOCATION AND DIMENSIONS OF PROPERTY LINES, (E) BUILDING OUTLINE, (E)
LOCATIONS OF SIDEWALK, DRIVEWAY AND UTILITIES ARE PER TOPOGRAPHIC
SURVEY
SITE PLAN GENERAL NOTES 15'-0" FRONT YARD SETBACK5'-0". SIDE YARD SETBACK
5'-0". SIDE YARD SETBACK5' - 0"13' - 11"12' - 0"11' - 0"4' - 1"5' - 5"
31' - 3"
PROPERTY LINE
PROPERTY LINEPROPERTY LINEPROPERTY LINE20'-0" REAR YARD SETBACK444 4
444444COVERED PORH
(E) 1-STORY
SINGLE FAMILY DWELLING
(E) 1-STORY
SINGLE FAMILY DWELLING
2ND STORY ADDITION
(E) 1-STORY
SINGLE FAMILY DWELLING
(E) GARAGE
LOS GATOS BLVD
NEIL JOHN
GINTY
C-37904
RENEWAL
DATE
C A L IF O RNIASTAT
E
OFLICENSED ARCHIT
E
CTMAY 31 2027
0
Sheet Title
Sheet No.
Scale
Drawn By:Checked By:
Job Number:
Issued For
Date:
Job Address
Job Title
Revision No.Date
Written dimensions on these drawings shall have precedence over scaled
dimensions. Drawings shall not be scaled. Contractors shall verify, and be
responsible for, all dimensions and conditions shown by these drawings.
Shop details must be submitted to this office for approval before proceeding
with fabrications. The drawings and their design content are the sole
property of Dwelling Lab, Inc. and may not be reused or reproduced in any
manner without our express written consent.
2'4'8'16'
Agency Approvals t.312.952.9680 | e.design@dwelling-lab.com | w.dwelling-lab.coma. 21 El Caminito, Walnut Creek, CA 94598As indicated
7/28/2025 4:24:10 PMA1.02
PROPOSED SITE PLAN
245 LOS GATOS BLVD, LOS GATOS,
CA 95030
5/7/2025
Project Status
Project Number
245 LOS GATOS BLVD
Author Checker
3/16" = 1'-0"1SITE PLAN_
LOCATION OF STRUCTURES WITHIN 50 FEET OF SUBJECT PROPERTY
245
241
247
242
250
236
212
220
07/28/2025
Page 230
W/D W/D
Refrig.
UP
W/D W/D
UP
UP
Refrig.
UP
W/DUP
(E) WALL TO BE REMOVED
(E) WALL TO REMAIN
(E) DOOR TO BE REMOVED
LEGEND -DEMOLITION
(E) AREA TO BE REMOVED (E) WINDOW TO BE REMOVED
(E) WINDOW TO REMAIN
(E) DOOR TO REMAIN
(E) ITEM TO BE REMOVED
1. GENERAL CONTRACTOR TO NOTIFY ARCHITECT
OF ANY DISCOVERY OF UNFORSEEN CONDITIONS
IN THE PROCESS OF DEMOLITION
2. (E) STRUCTURAL BEARING ELEMENTS TO REMAIN
U.O.N. GENERAL CONTRACTOR TO NOTIFY
ARCHITECT IF ANY BEARING COLUMNS ARE
FOUND IN PARTITIONS TO BE REMOVED THAT DO
NOT APPEAR IN PLANS.
3. DAMAGES WHICH OCCUR DURING DEMOLITION
AND/OR CONSTRUCTION SHALL BE THE GENERAL
CONTRACTOR'S RESPONSIBILITY AND EXPENSE
TO RESTORE/REPAIR TO ORIGINAL CONDITION.
4. IF ANY MATERIALS SUSPECTED OF CONTAINING
ASBESTOS OR ANY OTHER HAZARDOUS
MATERIALS ARE ENCOUNTERED, DO NOT
DISTURB THE MATERIALS. IMMEDIATELY NOTIFY
THE OWNER, OWNER'S
REP/LANDLORD/TENANT/CLIENT AND ARCHITECT.
DEMOLITION NOTES
32' - 1"15' - 6"15' - 4 1/8"14' - 5"
10' - 5"3' - 8"4' - 9 1/8"4' - 9 1/8"9' - 11"12' - 8"
11' - 10"3' - 6"13' - 4"19' - 4"9' - 10"8' - 9"16' - 10"2' - 3 7/8"3' - 5"1' - 7 5/8"4' - 2 13/16"
1' - 0"1' - 0"
40' - 10"20' - 1 7/8"7' - 10 1/8"13' - 9 1/8"44' - 8 7/8"15' - 4 1/2"LESS THAN 50% OF (E) EXTERIOR WALLS TO BE REMOVED
26' - 11"
A3.00
A3.00
A3.001
A3.00
5
7
3
11
A3.00
BEDROOM LIVING ROOM
BEDROOM
MEDIA ROOM
BATH
WIC
BATH
30' - 10"32' - 1"27' - 3"20' - 2"44' - 1"15' - 4"COVERED PORCH
13' - 7"15' - 6"1. DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED :
A) TO FACE OF FINISH
B) TO CENTER OF DOORS AND OTHER OPENINGS
C) TO TOP OF FINISHED FLOORS
D) TO BOTTOM OF FINISH AT CEILINGS
E) TO OUTSIDE FACE OF FINISHED MILLWORK
F) TO FINISHED WINDOW FRAME. SEE WINDOW DETAILS.
2. DIMENSIONS SHOWN AS V.I.F. SHALL BE VERIFIED BY THE CONTRACTOR
IN THE FIELD. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES IN DIMENSIONS PRIOR TO PROCEEDING WITH THE
WORK IN THAT AREA.
3. DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW
FOR THICKNESS OF FINISHES INCLUDING CERAMIC TILE, VCT, ETC.
DIMENSIONS MARKED "CLEAR" ARE TO BE WITHIN 1/8" OF GIVEN
DIMENSION ALONG FULL HEIGHT/WIDTH/LENGTH OF SURFACES.
4. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN PARTITION
LOCATIONS, DIMENSIONS AND TYPES. DOOR AND WINDOW LOCATIONS
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
NOTIFY ARCHITECT FOR WRITTEN CLARIFICATION PRIOR TO
PROCEEDING WITH CONSTRUCTION. CONSTRUCTION PLAN BY
ARCHITECT SUPERSEDES OTHER PLANS.
5. ANY GRAPHICAL ERRORS, APPARENT OR ASSUMED, SHOULD BE
CLARIFIED WITH AN RFI PRIOR TO CONSTRUCTION
DIMENSION NOTES
1. REPLACEMENT OF GYPBOARD MUST BE 5/8" TYPE X WITH 5D
COOLER NAILS AT 4 INCHES ON CENTER OR EQUIVALENT SCREWS
FOR ALL INTERIOR NON-STRUCTURAL ALTERATIONS.
2. REFER TO BUILDING CODE ANALYSIS FOR LOCATIONS OF FIRE
RESISTANCE RATED WALLS.
3. THERMAL INSULATION TO BE PROVIDED BETWEEN CONDITIONED
AND NONCONDITIONED SPACES TYP. REFER TO ASSEMBLY TYPES.
4. ACOUSTIC INSULATION TO BE PROVIDED IN ALL WALLS
SURROUNDING BATHROOM AND LAUNDRY AREAS (INCLUDES
MUDROOM AND BASEMENT STORAGE). REFER TO ASSEMBLY
TYPES.
5. PROVIDE (N) LEVELING SUBSTRATE o/ EXISTING/NEW SUBFLOOR
ASSEMBLY THROUGHOUT AS REQUIRED TO ACHIEVE SMOOTH
CONTIGUOUS, LEVEL (N) FINISH FLOORING; TYP.
6. ALL GUARDRAIL & HANDRAIL CONSTRUCTION SHALL WITHSTAND A
200 LB. CONCENTRATED LOAD AND 50 LB./ FT. UNIFORM LOAD
APPLIED LATERALLY AND VERTICALLY AT THE HIGHEST POINT OF
THE RAIL--WHICHEVER IS GREATER. (TYP. ALL GUARDRAILS) AS
SPECIFIED IN CBC SECTION 1607.8., S.S.D.
PROPOSED PLAN GENERAL NOTES LEGEND -NEW CONSTRUCTION
##
(E) WALL TO REMAIN
(N) WALL
ABOVE OR BELOW (N) WINDOW
[N.I.C.] NOT IN CONTRACT
1 HR. FIRE RESISTANCE
RATED WALL
(N) DOOR
(E) WINDOW TO REMAIN
XXX
(N) BEARING WALL
(N) FOOTING
HEADER OR BEAM
(N) BRACE WALL PANEL
A3.00
A3.00
5
3
11
A3.00
BEDROOM
BATH
BEDROOM BATH
13' - 5"5' - 0"5' - 4"20' - 0"26' - 11"
(E) ITEM TO BE REMOVED
LEGEND -DEMOLITION
(E) AREA TO BE REMOVED
(E) WALL TO REMAIN
(E) WALL TO REMAIN
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"LESS THAN 50% OF THE EXTERIOR WALLS
26' - 11"32' - 1"13' - 11"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
CLAY TILE ROOF
CORBEL
COLONIAL STYLE WINDOW
LANTERN
STUCCO WALLS
CLAY TILE VENTS
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
CLAY TILE ROOF
CORBEL
CLAY TILE VENTS
COLONIAL STYLE WINDOWS
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
CORBELS
CLAY TILE ROOF
TILE VENTS LANTERNS
COLONIAL STYLE WINDOW PROPOSED HEIGHT 24' - 7"FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
CLAY TILE ROOF
CORBEL
COLONIAL STYLE
WINDOW
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"
11
A3.00
FIRST FLOOR
0"
SECOND FLOOR
9' - 6 1/2"
ROOF
19' - 0"
AVERAGE GRADE
-1' - 0"PROPOSED HEIGHT 24' - 7"1. 0'-0" (E) FINISH FLOOR LEVEL AT 1ST FLOOR IS DETERMINED BY ELEVATION
MARK.
PROPOSED ELEVATIONS GENERAL NOTES
1. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFO.
2. 0'-0" (E) FINISH FLOOR LEVEL AT 1ST FLOOR IS DETERMINED BY ELEVATION
MARK
3. ACOUSTIC INSULATION TO BE PROVIDED IN ALL WALL, FLOOR, AND CEILING
ASSEMBLIES SURROUNDING BATHROOM AND LAUNDRY AREAS.
BUILDING SECTIONS GENERAL NOTES
1. DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED :
A) TO FACE OF FINISH
B) TO CENTER OF DOORS AND OTHER OPENINGS
C) TO TOP OF FINISHED FLOORS
D) TO BOTTOM OF FINISH AT CEILINGS
E) TO OUTSIDE FACE OF FINISHED MILLWORK
F) TO FINISHED WINDOW FRAME. SEE WINDOW DETAILS.
2. DIMENSIONS SHOWN AS V.I.F. SHALL BE VERIFIED BY THE CONTRACTOR
IN THE FIELD. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES IN DIMENSIONS PRIOR TO PROCEEDING WITH THE
WORK IN THAT AREA.
3. DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW
FOR THICKNESS OF FINISHES INCLUDING CERAMIC TILE, VCT, ETC.
DIMENSIONS MARKED "CLEAR" ARE TO BE WITHIN 1/8" OF GIVEN
DIMENSION ALONG FULL HEIGHT/WIDTH/LENGTH OF SURFACES.
4. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN PARTITION
LOCATIONS, DIMENSIONS AND TYPES. DOOR AND WINDOW LOCATIONS
SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT,
NOTIFY ARCHITECT FOR WRITTEN CLARIFICATION PRIOR TO
PROCEEDING WITH CONSTRUCTION. CONSTRUCTION PLAN BY
ARCHITECT SUPERSEDES OTHER PLANS.
5. ANY GRAPHICAL ERRORS, APPARENT OR ASSUMED, SHOULD BE
CLARIFIED WITH AN RFI PRIOR TO CONSTRUCTION
DIMENSION NOTES LEGEND -NEW CONSTRUCTION
(E) WALL TO REMAIN
(N) WALL
ABOVE OR BELOW
[N.I.C.] NOT IN CONTRACT
1 HR. FIRE RESISTANCE
RATED WALL
PREPARED BY: Sean Mullin, AICP
Planning Manager
110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874
www.losgatosca.gov
TOWN OF LOS GATOS
HISTORIC PRESERVATION
COMMITTEE REPORT
MEETING DATE: 08/27/2025
ITEM NO: 6
DATE: August 22, 2025
TO: Historic Preservation Committee
FROM: Joel Paulson, Community Development Director
SUBJECT: Consider a Request for Preliminary Review to Construct an Addition with
Reduced Setbacks to an Existing Noncontributing Single-Family Residence
Located in the Almond Grove Historic District on Nonconforming Property
Zoned R-1D:LHP. Located at 321 Bachman Avenue. APN 510-17-100. Exempt
Pursuant to CEQA Section 15301: Existing Facilities. Request for Review
Application PHST-25-016. Property Owner: Stanley and Jean Melax.
Applicant: Jennifer Kretschmer, AIA. Project Planner: Sean Mullin.
RECOMMENDATION:
Consider a request for preliminary review to construct an addition with reduced setbacks to an
existing noncontributing single-family residence located in the Almond Grove Historic District
on nonconforming property zoned R-1D:LHP, located at 321 Bachman Avenue.
PROPERTY DETAILS:
1. Date primary structure was built: 1949 per County Assessor’s Database
2. Bloomfield Preliminary Rating: New, probably built since 1950
3. Does property have an LHP Overlay? Yes
4. Is structure in a historic district? Almond Grove Historic District
5. If yes, is it a contributor? No
6. Findings required? No
7. Considerations required? Yes
BACKGROUND:
The subject property is located on the south side of Bachman Avenue between Massol and Tait
Avenues, just west of the alley. The County Assessor reports that the residence was constructed
in 1949. The Anne Bloomfield survey notes the structure as new, probably built since 1950.
(Attachment 1).
Page 233
PAGE 2 OF 3
SUBJECT: 321 Bachman Avenue/PHST-25-016
DATE: August 22, 2025
The residence is present on the 1944 and 1956 Sanborn Fire Insurance Maps (Attachment 2).
The footprint of the residence remains consistent between the two dates. Additions and other
modifications have been constructed since 1956, as noted below.
As provided in Attachment 3, Town records include the following permitted work:
1974: Replacement of windows with a sliding door leading to a new patio deck at the
rear of the residence;
1981: Reconstruction of the garage roof to accommodate solar collectors;
1987: Reroof;
1991: Add skylights;
1995: Demolish portions of the residence (467 sf) and garage (198 sf) and construct a
new bedroom addition (300 sf) at the left rear of the residence; and
2017: Reroof.
DISCUSSION:
The applicant provided a Letter of Justification for the proposed project (Attachment 3). The
applicant is requesting preliminary review of a proposal to add an attached single-car garage at
the rear of the property, opening up to the alley (Attachment 7). A new covered porch
supported with square columns would be added to the front elevation, along with a new bay
extension with a fiberglass window with wood trim. Another new porch with square columns
would be constructed on the left elevation. The applicant indicates that the additions and new
detailing are intended to make the residence look more Victorian in style, consistent with other
nearby homes (Attachment 4).
The Letter of Justification (Attachment 4) discusses future plans to incorporate an accessory
dwelling unit (ADU) above the new attached garage, shown in light-line in the development
plans (Attachment 7). Any future ADU would be processed ministerially, consistent with State
law. Staff notes that the ADU is not the subject of this application and shall not be used as the
basis for any feedback provided to the applicant.
CONSIDERATIONS:
A. Considerations
Sec. 29.80.290. Standards for review.
In evaluating applications, the deciding body shall consider the architectural style, design,
arrangement, texture, materials and color, and any other pertinent factors. Applications
shall not be granted unless:
Page 234
PAGE 3 OF 3
SUBJECT: 321 Bachman Avenue/PHST-25-016
DATE: August 22, 2025
_ In historic districts, the proposed work will neither adversely affect the exterior
architectural characteristics or other features of the property which is the subject of
the application, nor adversely affect its relationship, in terms of harmony and
appropriateness, with its surroundings, including neighboring structures, nor adversely
affect the character, or the historical, architectural or aesthetic interest or value of the
district.
B. Residential Design Guidelines
Section 3.9 of the Town’s Residential Design Guidelines offers recommendations for
construction of additions to existing residences (Attachment 6).
CONCLUSION:
The applicant is requesting preliminary feedback from the Committee on a proposal to
construct an addition with reduced setbacks to an existing noncontributing single-family
residence located in the Almond Grove Historic District on nonconforming property zoned R-
1D:LHP, located at 321 Bachman Avenue. Due to the proposed reduced setbacks on the
nonconforming property, the project requires Architecture and Site approval. The formal
application would be forwarded to the Committee for a recommendation to the deciding body.
ATTACHMENTS:
1. Anne Bloomfield Survey
2. Sanborn Fire Insurance Maps Exhibit
3. Town Permit Records
4. Letter of Justification
5. Photos of Existing Residence
6. Section 3.9, Residential Design Guidelines
7. Development Plans
Page 235
This Page
Intentionally
Left Blank
Page 236
This Page
Intentionally
Left Blank
Page 238
1944
321 Bachman Ave
ATTACHMENT 2
Page 239
1956
321 Bachman Ave
Page 240
ATTACHMENT 3Page 241
Page 242
Page 243
Page 244
Page 245
Page 246
Page 247
Page 248
Page 249
Page 250
Page 251
Page 252
Page 253
Page 254
Page 255
Page 256
Page 257
Page 258
Page 259
Page 260
Page 261
Page 262
Page 263
Page 264
Page 265
Page 266
Page 267
Page 268
Page 269
Page 270
Page 271
Page 272
Page 273
Page 274
Page 275
Page 276
Page 277
Page 278
Page 279
Page 280
Page 281
Page 282
Page 283
Page 284
Page 285
Page 286
Page 287
Page 288
Page 289
Page 290
Page 291
Page 292
Page 293
Page 294
Page 295
Page 296
Page 297
This Page
Intentionally
Left Blank
Page 298
Homeowner’s Statement
(Includes justification statement and historical research details)
To whom it may concern,
We moved to Los Gatos in 2010 and lived many years in a townhouse in the Vasona Terrace
complex. Our kids went to Los Gatos schools. When they grew up and moved out, we moved to
the Almond Grove neighborhood, to 321 Bachman Avenue in September 2024. We love this
quiet historic neighborhood!
Our plan for the home is to add an attached single car garage in the back of the property
opening to the alley, add an ADU above the garage if possible, and add more
historically-inspired elements to the front and side of the house to allow it to fit in better with the
other historic homes nearby. We feel that turning the large front window into an (above ground)
bay window and adding covered porches to the front and side would accomplish this task.
Adding a garage in the back of the house off the alley would allow us to park and charge our
electric car and free up a space on the street, as well as provide much needed storage space
for this small house. We plan to have the garage, porches, and bay window fit aesthetically with
the existing house and add elements to make it look more Victorian style like other houses
nearby.
We would also like to move our laundry area from the kitchen to the new garage, since the
kitchen is small we would rather use the washer/dryer space for kitchen storage instead.
If the ADU is not approved, we would like to make the garage as tall as possible to allow for us
to have as much attic / loft storage space as possible. The garage will be in the back of the
house away from the front street and the garage of our next door neighbor’s house (to the west,
at 240 Massol Avenue) is already taller than our house so we hope a garage of the maximum
allowable height will be acceptable (see photo of the neighbor's garage later in this document).
If the ADU is not approved, we would also like to have a full bathroom in the garage as well, for
convenience.
The house already has some areas that extend into the easements, but we do not plan to build
further into those areas, except for the garage itself. This property is small and non-standard
and we plan to apply to get approval to have the garage built closer than 5 feet from the south
property line in order to get as much garage space as is allowed. We have noticed other
garages and structures for houses backing on to the same alley that are already quite
close to their property lines (3 feet or less), so we hope a 3 or 4 feet easement would be
an acceptable distance. For example:
-231 Tate Avenue has a ‘cottage’ structure next to the alley that looks to be right up
against the property line, the fence on the south side is only about a foot from the
structure. The cottage was built around 1965 (source: 2005 historic tour brochure).
ATTACHMENT 4
Page 299
-225 and 223 Tate Avenue have garages opening to the alley that are only about 3 ft from
their fences on the right (south).
-217 Tate Avenue has a carport opening to the alley that is only about 3 ft from their fence
on the right (south)
-The garage for our immediate neighbor’s house (240 Massol) appears to be between
about 4ft from our fence at one end but only about 2 ft from our fence at the other.
We logged into the computer in the lobby of the LG planning office and looked at what was on
file for our own house as well as properties nearby. Details are on later pages in this document
but here are the highlights:
-1996 Architectural plans for our own house showed that it used to have a garage
with a ‘bedroom/loft’ above the garage. This was demolished in 1996 and replaced
with a new bedroom and bathroom attached to the main house. We have obtained
approval from the architect from 1996 (who is still in business) and attached copies of
the plans to this application.
-We also found architectural diagrams on file for 312 Bachman (across the street) and
240 Massol (next door), but neither of the diagrams showed easement lines (only
property lines). The plans for 240 Massol especially do seem to confirm that the garage
is very close to the fence between our two properties and is likely nonconforming (see
later pages for details)
We did some research at the Los Gatos library as well. Details are in later pages in this
document but here are the highlights:
-Our house was built in 1939, based on the 1941 Tax Assessment Survey (the
survey says the house was 2 years old at the time). This differs from what the real
estate listing says (1949).
-We think our house used to be part of the property at 240 Massol Avenue, based on the
‘Remodeling’ section of a 1971 survey where the owner said “back property split up
and sold to closest property owners”, but it doesn’t give a year. (source: Historic
Property Research Collection)
We have spoken to our immediate neighbours at 307 Bachman (immediate neighbor to the left
(east), across the alley), 240 Massol (immediate neighbor to the right (west)), and 232 Massol
(immediate neighbor behind us, backing onto the same alley, we share a fence), and they don’t
have any issues with us building an attached garage.
Please see the rest of the pages in this document for pictures of nearby houses and more
details on the research we did.
Thank you for your time considering our application. Let us know if you have any questions.
Stanley and Jean Melax
321 Bachman Avenue, Los Gatos CA
Page 300
Photos of nearby structures:
The garage for our immediate neighbor to the right (240 Massol) is about 4 ft from our shared
fence at one end, but only about 2 ft away from our shared fence at the other end:
Page 301
The garage at 240 Massol (next door neighbor) is taller than our house:
View of the alley, standing next to our house, looking South. Note the first structure, a ‘cottage’
at the back of 231 Tate, is very close to the alley, so probably very close to the property line.
Page 302
The ‘cottage’ at the back of 231 Tate is within a foot of the fence on the right side:
Page 303
The garage at the back of 225 Tate is about 3 feet from the fence to its right:
Page 304
The garage at the back of 223 Tate is about 3 feet from the fence to its right:
Page 305
The carport at the back of 217 Tate is about 3 feet from the fence to its right:
Page 306
321 Bachman Avenue Research Notes (more details)
We purchased the house from Patricia Ann McCaffrey on 9/25/2024
For quick reference, these are the properties nearby:
1.328 Bachman (across the street)
2.320 Bachman (across the street)
3.312 Bachman (across the street)
4.308 Bachman (across the street)
5.300 Bachman (across the street)
6.307 Bachman (immediate neighbor to the left (east), across the alley)
7.240 Massol (immediate neighbor to the right (west))
8.232 Massol (immediate neighbor behind us, backing onto the same alley, we share a
fence)
9.231 Tate (nearby, backs on to the same alley)
10.225 Tate (nearby, backs on to the same alley)
11.303 Bachman (two houses to the left (east)
LG Planning department computer 7/25/2025
321 Bachman: there are 1996 architectural diagrams in the microfiche folder showing a
new primary bedroom and a bathroom were added, and that an existing garage with a
“bedroom / loft” above it was demolished. The architect (Gary Kohlsaat,
garyk@kohlsaatarch.com) gave permission for me to have copies of the plans (received
8/4/2025 and are included with this application).
LG Planning department computer 8/1/2025
-#1: has permit applications on file but no architectural plans
-#3: lots of architectural plans to add a basement, etc, but none showed property lines
-#6: no architectural diagrams or plans; 2018 permit to refurbish cottage, new front door,
5 new windows; secondary dwelling unit approved in 1985 but no plans on file
-#7: 103 pages of microfiche, ran out of time to review them all but there was a 1974
architectural diagram that might be relevant but the scans were very faint.
-#10: ran out of time to research fully
-#11: building permit on file for 1951 but no architectural plans on file
-Nothing major on file for the other neighbors
Page 307
LG Library 8/3/2025
We planned to look at the Sanborn Maps on file at the LG library but the ‘history room’ was not
open the day we did the research (only open Tuesdays from 11:30-1:30 according to the sign on
the door)
Project Bellringer: only #1 was included on the list in the binder, but a newspaper article from
1976 says #9 was a “Bellringer house” too.
Historic Property Research Collection:
-#1: Sometime between 1934 and 1945 added a small porch off the dining room, and
front porch was screened in with climbing roses and honeysuckle, ‘garage had been in
lower backyard’, built estimated “1885 A.K”.
-#7: ~1880 A.K., under ‘Remodeling’ section of 1971 survey says “back property
split up and sold to closest property owners” but doesn’t give a year. Also says “33
ft additional in back area” and “garage used for office”.
-#9: a 2005 historic tour brochure says “about 1965, Douglas and Marjorie Rose
purchased the property and built a cottage on the back of the lot that they rented out in
addition to the house. That cottage is not open for viewing”, 1976 newspaper article says
it is a Bellringer house, has a phantom front door that once opened to Tate but now front
door is elsewhere
-#10: has a folder but nothing relevant to our project
-No other houses above has folders in the collection
Anne Bloomfield's Survey of 1991: none of the nearby houses are included, nothing on
Bachman or Massol, a few on Tate but only up to #30 Tate.
1941 Tax Assessment Survey (note these show dimensions of buildings but not their
relationship to property lines):
-321 Bachman: says the house was 2 years old in 1941, a scan is included in this
application
-#1: 45 years old
-#2: 17 years old
-#3: 40 years old
-#4: 40 yo
-#5: 10 yo
-#6: not included
-#7: 30 years old, worth $1700
-#8: not included
-#9: 40 years old
-#10: not included
Page 308
Planning department computer 8/4/2025:
LFTown / planning / address files / Bachman Ave / 321 / microfiche folder:
-Nothing under any of the other folders
-Home occupation permit 5/26/88 for Joyce Bahnsen
-97 scanned pages. Filled out form to request these documents on 8/4/2025.
-Page 71 and 82: exhibit C PLAT to accompany the lot line adjustment Feb 1996
(page 82) and Sep 1996 (page 71). Filled out form to request these documents on
8/4/2025.
FTown / building / address / Bachman Ave / 321 folder (requested and received copies of all on
8/4/2025):
-permits folder has 3 folders:
-B17-0257 - permit for new roof - 4/21/2017
-E18-135 - permit for add three circuit to allow the remaining knob and tube that is
in use to be abandon, alter 19 lights, switches and outlets 10/05/2018
-M18-102 - permit to install condenser 7/12/2018
-Plans folder has one folder B21-0233: plans for chimney repair 3/21/17
-Microfiche folder has 49 pages including the architectural diagrams
240 Massol
-Has plans approved 1/20/15 is for removing a brick fireplace and window, adding a
breakfast nook, etc but the plans also show the existing garage
-On the 2015 plans, the only thing that looks nonconforming to easements is the garage.
There is no scale marking on the plans but it is 3/16” away from the fence when viewed
at 50%
-“The Poncetta Residence”
-Architect: Flury Bryant design group
312 Bachman
-Page 94 of microfiche has an architectural plan. The only thing that might be
non-conforming is the extended garage (I think, its hard to read as the focus of the
diagrams was the main house only)
-17 May 2004, approved 6/21/2004
-“Hubbard Santangeli Residence”
-Architect E. Gary Schloh
LG library, 8/4/2025:
Polk directories (shows residents of 321 Bachman):
1939, 1940: 321 Bachman is not listed
Page 309
1941: Biermann C F
1943, 1944, 1945: Kleiner Rudolph
1947: Countryman J. L.
1949-50, 1954, 1956, 1958: Fetsch Carrie Mrs
1952: no pink street guide section
1955: no Los Gatos in guide
1960, 1962, 1964: Young Doris Mrs
1965: Vandeberg Bessie E Mrs
1967: “vacant”
1968: Smyth Ethelyn H Mrs
1969: “no return”
1970, 1971, 1972, 1974: Hamner Eldo Mrs (spelled Hammer in 1970)
1974 was last Polk Directory on file, telephone directories after that don’t have street look-up
Page 310
.,.,,,..
ATTACHMENT 5
Page 311
Page 312
Page 313
Page 314
Page 315
Page 316
Page 317
Page 318
Page 319
Page 320
Page 321
Page 322
Page 323
Page 324
Page 325
Page 326
Page 327
Page 328
Page 329
Page 330
Page 331
Page 332
Page 333
Page 334
Page 335
Page 336
Page 337
Page 338
Page 339
Page 340
Page 341
Page 342
Page 343
Page 344
Page 345
Page 346
Page 347
Page 348
Page 349
Page 350
Page 351
Page 352
Page 353
Page 354
Page 355
Page 356
Page 357
Page 358
Page 359
Page 360
Page 361
Page 362
Page 363
Page 364
Page 365
Page 366
Page 367
This Page
Intentionally
Left Blank
Page 368
Residential Design Guidelines 33
Town of Los Gatos BUILDING DESIGN3
3.8.3 Use traditional detailing
•Treat openings in walls as though they were constructed of
the traditional material for the style. For example, be sure to
provide substantial wall space above arches in stucco and
stone walls. Traditionally, wall space above the arch would
have been necessary to structurally span the opening, and
to make the space too small is inconsistent with the archi-
tectural style.
•Openings in walls faced with stone, real or synthetic, should
have defined lintels above the opening except in Mission or
Spanish Eclectic styles. Lintels may be stone, brick or wood
as suits the style of the house.
•Treat synthetic materials as though they were authentic.
For example, select synthetic stone patterns that place the
individual stones in a horizontal plane as they would have
been in a load bearing masonry wall.
•Select roof materials that are consistent with the traditional
architectural style (e.g., avoid concrete roof tiles on a Crafts-
man Style house.)
3.8.4 Materials changes
•Make materials and color changes at inside corners rather
than outside corners to avoid a pasted on look.
3.9 ADDITIONS/ACCESSORY BUILDINGS/SECONDARY
UNITS
•Site additions in the least conspicuous place. In many cases
this is a rear or side elevation - only rarely is it a rooftop.
•The existing built forms, components and materials should
be reinforced. Heights and proportions of additions and
alterations should be consistent with and continue the
original architectural style and design.
•Additions should be subordinate, and compatible in scale
and proportion to the historically significant portions of
the existing structure.
•When an addition or remodel requires the use of newly
constructed exterior elements, they should be identical in
size, dimension, shape and location as the original, and
Use stone or wood lintels over
openings in stone walls
Additions, accessory buildings and secondary
units should match the form, architectural
style, and details of the original house
ATTACHMENT 6
Page 369
Residential Design Guidelines34
Town of Los Gatos
BUILDING DESIGN3
should utilize the same materials as the existing protected
exterior elements.
•When an addition necessitates the removal of architectural
materials, such as siding, windows, doors, and decorative
elements, they should be carefully removed and reused in
the addition where possible.
•The introduction of window and door openings not char-
acteristic in proportion, scale, or style with the original
architecture is strongly discouraged (e.g., sliding windows or
doors in a structure characterized by double hung windows
and swinging doors).
•The character of any addition or alteration should be in
keeping with and subordinate to the integrity of the original
structure.
•The amount of foundation exposed on the addition should
match that of the original building.
•Do not add roof top additions where the roof is of historic
significance.
•Second floor additions are discouraged in neighborhoods
with largely one story homes. If horizontal expansion of
the house is not possible, consider incorporating a second
floor addition within the roof form as shown in the example
to the left.
•Second floor additions which are not embedded within the
roof form should be located to the rear of the structure.
•The height and proportion of an addition or a second story
should not dominate the original structure.
•Deck additions should be placed to the rear of the struc-
ture only, and should be subordinate in terms of scale and
detailing.
•New outbuildings, such as garages, should be clearly subor-
dinate to the main structure in massing, and should utilize
forms, materials and details which are similar to the main
structure.
•Garages should generally be located to the rear of the lot
behind the rear wall of the residence. One car wide access
driveways should be utilized.
Original structure
Addition incorporated into the roof
successfully adds space while respecting the
integrity of the existing house and the scale of
the neighborhood
Placing a two story addition to the rear can minimize its impact on the historic resource and the scale of the neighborhood
Page 370
Page 371
Page 372
Page 373
Page 374
Page 375
Page 376
Page 377
This Page
Intentionally
Left Blank
Page 378