Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Staff Report with Exhibits 1 through 9.16511 Cypress Wy
PREPARED BY: Suray Nathan Assistant Planner Reviewed by: Planning Manager and Community Development Director 110 E. Main Street Los Gatos, CA 95030 ● (408) 354-6872 www.losgatosca.gov TOWN OF LOS GATOS PLANNING COMMISSION REPORT MEETING DATE: 04/23/2025 ITEM NO: 5 DATE: April 18, 2025 TO: Planning Commission FROM: Joel Paulson, Community Development Director SUBJECT: Consider a Request for Approval to Demolish an Existing Accessory Structure and Construct a New Accessory Structure Exceeding 1,000 Square Feet in Gross Floor Area and Site Improvements Requiring a Grading Permit on Property Zoned HR-2½. Located at 16511 Cypress Way. APN 532-24-004. Architecture and Site Application S-24-045. Exempt Pursuant to the CEQA Section 15303(a): New Construction or Conversion of Small Structures. Property Owners: Jackie and Scott Kolander. Applicant: Michael Harris. Project Planner: Suray Nathan. RECOMMENDATION: Denial. PROJECT DATA: General Plan Designation: Hillside Residential (0-1 dwelling unit/acre) Zoning Designation: HR-2½ - Hillside Residential Applicable Plans & Standards: Town Code, General Plan, Hillside Development Standards and Guidelines Parcel Size: 54,624 square feet Surrounding Area: Existing Land Use General Plan Zoning North Residential Hillside Residential HR-2½ South Residential Hillside Residential HR-2½ East Residential Hillside Residential HR-2½ West Residential Hillside Residential HR-2½ Page 43 PAGE 2 OF 7 SUBJECT: 16511 Cypress Way/S-24-045 DATE: April 18, 2025 CEQA: The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303(a): New Construction or Conversion of Small Structures. FINDINGS: The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303(a): New Construction or Conversion of Small Structures; As required by Section 29.10.09030 (b)(2) of the Town Code for the demolition of an existing accessory structure; The project meets the objective standards of Chapter 29 of the Town Code (Zoning Regulations); The project is in compliance with the Hillside Development Standards and Guidelines for single-family residences with the exceptions to grading depths and light reflective value; and The project complies with the Hillside Specific Plan. CONSIDERATIONS: As required by Section 29.20.150 of the Town Code, the considerations in review of an Architecture and Site application were all made in reviewing this project. ACTION: The decision of the Planning Commission is final unless appealed within ten days. BACKGROUND: The subject property is located on the south side of Cypress Way, approximately 1.4 miles southeast of Los Gatos Boulevard (Exhibit 1). All surrounding properties are zoned Hillside Residential and developed with single-family residential uses. The property is zoned HR-2½ and has a gross lot size of 54,624 square feet. The average slope of the property is 32 percent, and the resulting net lot size is 21,849 square feet. On August 30, 2024, the applicant applied for an Architecture and Site Application for a 1,239- square foot detached accessory structure consisting of a three-car garage with a workshop. The proposed project meets the technical requirements of the Town Code for floor area, height, setbacks, and on-site parking. As required by the Hillside Development Standards and Guidelines (HDS&G), the project is being considered by the Planning Commission due to the proposed accessory structure exceeding 1,000 square feet in gross floor area. The applicant also requests exceptions to the HDS&G standards for light reflective value (LRV) and the depth Page 44 PAGE 3 OF 7 SUBJECT: 16511 Cypress Way/S-24-045 DATE: April 18, 2025 of cut exceeding the maximum allowed for accessory buildings. PROJECT DESCRIPTION: A. Location and Surrounding Neighborhood The subject property is located on the south side of Cypress Way, approximately 1.4 miles southeast of Los Gatos Boulevard (Exhibit 1). All surrounding properties are zoned Hillside Residential and developed with single-family residential uses. B. Project Summary The applicant is proposing a new 1,239-square foot detached accessory structure consisting of a three-car garage with a workshop. The proposed accessory structure would be located at the southeast end of the hillside property. The structure would have a maximum height of 15 feet, the maximum allowed for accessory structures. The project requires exceptions to the HDS&G for a LRV exceeding 30 and the depth of cut exceeding the maximum allowed for accessory buildings, hardscape, and landscape. C. Zoning Compliance A single-family residence is permitted in the HR-2½ zone. The proposed residence is in compliance with the allowable floor area, height, setbacks, and on-site parking requirements. DISCUSSION: A. Architecture and Site Analysis The applicant proposes demolition of the existing 587-square foot two-car garage and attached 96-square foot shed with a breezeway (Exhibit 9, Sheet T-1). The maximum allowable floor area ratio for the subject lot is 4,900 square feet, and the total existing floor area is 3,777 square feet. The applicant proposes construction of a new 1,239-square foot, three-car garage with an approximately 19-foot breezeway for a total proposed floor area of 4,333 square feet. The site is located in a hillside neighborhood with large lots and many mature trees. The proposed garage is designed to complement the existing house, with three dormer windows that bring natural light into the interior. The applicant provided a Letter of Justification detailing the project and the requested exceptions to the HDS&G (Exhibit 4 and Exhibit 5). A summary of the floor area for the existing structures and the proposed garage is included in the following table. Page 45 PAGE 4 OF 7 SUBJECT: 16511 Cypress Way/S-24-045 DATE: April 18, 2025 Floor Area Summary Existing Square Footage Proposed Square Footage Main Level (Single Story) 2,377 2,377 Accessory Structure 1,117 1,117 Attached Structure 96 0 Garage 587 1,239 Subtotal 4,177 4,733 Garage Credit (up to 400 sf) (400) (400) Total Countable Floor Area 3,777 4,333 B. Building Design The Town’s Consulting Architect reviewed the proposed three-car garage with a breezeway on September 17, 2024 (Exhibit 6). The Consulting Architect had no issues or concerns and stated in the report that the proposed structure is characteristic of a carriage house style and shielded by landscaping from views of any adjacent neighbors. The Consulting Architect provided no recommendations for changes. C. Building Height and Visibility The proposed garage has a maximum height of 15 feet, which is the maximum allowable height per the HDS&G. The proposed structure is not visible per the HDS&G’s visibility analysis criteria. D. Grading The project includes site improvements outside of the building footprint with grading quantities of 293 cubic yards, exceeding the 50 cubic yard threshold for requiring approval of a Grading Permit. Site grading is summarized in the table below. Site Grading Summary (cubic yards) Cut Fill Landscape 236 0 Hardscape 57 0 Total 293 0 E. Exceptions to the Hillside Development Standards and Guidelines Light Reflective Value exceeding 30 (Chapter V, Standard I.2, page 44): The HDS&G includes a standard requiring that building colors and materials blend with the predominant colors and values of the surrounding natural environment. It requires that the colors of exterior materials for structures that are not visible do not exceed an average LRV Page 46 PAGE 5 OF 7 SUBJECT: 16511 Cypress Way/S-24-045 DATE: April 18, 2025 of 30. The applicant proposes a color that matches the existing primary house, which has an LRV of 69, and the colors for facia, gutters, and downspouts of the house have an LRV of 93. The applicant requests an exception to allow the application of the same color and materials with a greater LRV so the proposed structure will match the existing structure. Grading depth of cut exceeding the maximum allowed (Chapter III, Standard A.1, page 20): The HDS&G limits grading cut depths outside the footprint of a primary residence to four feet. The applicant proposes maximum cut depths of 13 feet, six inches, for the accessory building (garage), 11 feet for the hardscape, and seven feet for the landscape. The following table illustrates the proposed cut depths. Maximum Graded Cuts and Fills Depth Site Element Proposed Cut Depth (Ft) Max Allowed Cut Depth (Ft) Fill Earthwork Cut (CY) Accessory building 13.5 4 0 122 Hardscape 11 4 0 57 Landscape 7 4 0 236 Exhibit 9, Sheet A1.1, illustrates the depth of cuts for the accessory building (blue), hardscape (maroon), and landscape (green). The applicant notes in the Letter of Justification that the grading and cut depths are needed to maintain the same pad elevation as the existing garage and that elevating the garage would require significantly more grading and asphalt modifications. The applicant added that the same is true for additional cuts for the hardscape and landscape (Exhibit 5). F. Tree Impacts The development plans were reviewed by the Town’s Consulting Arborist (Exhibit 7). The inventory contains 10 protected trees comprised of seven different species: three coast live oaks; two canary island pines; one holly; one pistache; one black pine; one Monterey pine; and one silk tree. The project proposes removal of eight protected trees (#615, #617, #618, #619, #620, #623, and #624), including a pine tree. The pine tree was proposed for removal after the Town’s Consulting Arborist review, but the Town’s Arborist verified the size and species (Exhibit 9, Sheet A1.0). The Consulting Arborist provided recommendations for tree preservation and planting 26 replacement trees to offset the proposed tree removal. In the Letter of Justification for the project (Exhibit 5), the applicant states that they are not proposing any tree replacement as planting new trees will result in a greater fire hazard than the original condition. The applicant proposes in-lieu fees as an alternative to the recommended planting of 26 trees. Page 47 PAGE 6 OF 7 SUBJECT: 16511 Cypress Way/S-24-045 DATE: April 18, 2025 G. Parking and Guest Parking Pursuant to Section 29.10.150 (c)(1) of the Town Code, a single-family residence requires two on-site parking spaces. The applicant has satisfied the requirement by including a detached three-car garage. The Hillside Specific Plan requires four additional guest parking spaces, and four guest spaces are proposed on the north side of the existing driveway (Exhibit 9, Sheet A1.1). H. Neighbor Outreach The applicant provided a sample letter and the list of homes where they hand-delivered the letter. They noted that only two neighbors are in the immediate vicinity of the property (Exhibit 8). No public comment was received at the time of this report's preparation. I. CEQA Determination The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303(a): New Construction or Conversion of Small Structures. PUBLIC COMMENTS: Story poles are not required for this project as it is an accessory structure under 18 feet in height. Written notice was sent to property owners and residents within 500 feet of the subject property. No public comment was received at the time of this report's preparation. CONCLUSION: A. Summary The applicant is requesting approval of an Architecture and Site application to demolish an existing accessory structure and construct a new accessory structure exceeding 1,000 square feet in gross floor area and site improvements requiring a Grading Permit on property zoned HR-2 ½. The project is consistent with the property's zoning and General Plan Land Use designation. The project is in compliance with the objectives standards of the Town Code related to allowable floor area, height, setbacks, and on-site parking requirements. Due to the desired architectural program and the site's constraints, the applicant requests exceptions to the HDS&G for a LRV exceeding 30 and the depth of cut exceeding the maximum allowed for an accessory building (garage), hardscape, and landscape. The applicant provided a Letter of Justification discussing these requested exceptions (Exhibit 5). Aside from the requested exceptions, the project complies with the HDS&G. Page 48 PAGE 7 OF 7 SUBJECT: 16511 Cypress Way/S-24-045 DATE: April 18, 2025 B. Recommendation Based on the analysis provided above, staff recommends that the Planning Commission deny the Architecture and Site application as the proposed LRV and the depth of cut are not consistent with the HDS&G standards. C. Alternatives Alternatively, the Commission can: 1. Approve the application by taking the following actions: a. Make the finding that the proposed project is Categorically Exempt pursuant to the adopted Guidelines for the implementation of the California Environmental Quality Act, Section 15303(a): New Construction or Conversion of Small Structures (Exhibit 2); b. Make the findings as required by Section 29.10.09030 (b)(2) of the Town Code for the demolition of an existing accessory structure (Exhibit 2); c. Make the finding that the project complies with the objective standards of Chapter 29 of the Town Code (Zoning Regulations) (Exhibit 2); d. Make the finding that the project complies with the Hillside Development Standards and Guidelines, with the exception to grading depths and LRV (Exhibit 2); e. Make the considerations as required by Section 29.20.150 of the Town Code for granting approval of an Architecture and Site application (Exhibit 2); and f. Approve Architecture and Site application S-24-045 with the conditions contained in Exhibit 3 and the development plans in Exhibit 9. 2. Continue the matter to a date certain with specific direction; or 3. Approve the application with additional and/or modified conditions. EXHIBITS: 1. Location Map 2. Required Findings 3. Recommended Conditions of Approval 4. Project Description 5. Letter of Justification 6. Consulting Architect’s Report 7. Consulting Arborist’s Report 8. Applicant’s neighborhood outreach efforts 9. Development Plans Page 49 This Page Intentionally Left Blank Page 50 TWELVE OAKS RDPASEO CARMELORAVINIA WYMI R E V A L R D 16511 Cypress Way 0 0.250.125 Miles ° Update Notes:- Updated 12/20/17 to link to tlg-sql12 server data (sm)- Updated 11/22/19 adding centerpoint guides, Buildings layer, and Project Site leader with label- Updated 10/8/20 to add street centerlines which can be useful in the hillside area- Updated 02-19-21 to link to TLG-SQL17 database (sm)- Updated 08-23-23 to link to "Town Assessor Data" (sm) EXHIBIT 1Page 51 This Page Intentionally Left Blank Page 52 N:\DEV\PLANNING PROJECT FILES\Cypress Way\16511\S-24-045\Public Meeting Documents\Planning Commission\ PLANNING COMMISSION – April 23, 2025 REQUIRED FINDINGS AND CONSIDERATIONS FOR: 16511 Cypress Way Architecture and Site Application S-24-045 Consider a Request for Approval to Demolish an Existing Accessory Structure and Construct a New Accessory Structure Exceeding 1,000 square feet in Gross Floor Area and Site Improvements Requiring a Grading Permit on Property Zoned HR- 2½. APN 532-24-004. Exempt Pursuant to the CEQA Section 15303(a): New Construction or Conversion of Small Structures. Property Owners: Jackie and Scott Kolander Applicant: Michael Harris Project Planner: Suray Nathan FINDINGS Required finding for CEQA: ■ The project is Categorically Exempt pursuant to the adopted Guidelines for the Implementation of the California Environmental Quality Act, Section 15303(a): New Construction or Conversion of Small Structures. Required finding for the demolition of existing structures: ■ As required by Section 29.10.09030 (b)(2) of the Town Code for the demolition of an existing accessory structure: 1. The Town's housing stock will be maintained as the accessory structure proposed for demolition is not a dwelling unit; 2. The existing structure has no architectural or historical significance; 3. The property owner does not desire to maintain the structure as it exists; and 4. The economic utility of the structures was considered. Required compliance with the Zoning Regulations: ■ The project meets the objective standards of Chapter 29 of the Town Code (Zoning Regulations). Required compliance with the Hillside Development Standards and Guidelines: ■ As required by the Hillside Development Standards and Guidelines (HDS&G), the project is in compliance with the applicable sections of the HDS&G with the exceptions to grading depths and light reflective value. EXHIBIT 2 Page 53 N:\DEV\PLANNING PROJECT FILES\Cypress Way\16511\S-24-045\Public Meeting Documents\Planning Commission\ Compliance with Hillside Specific Plan ■ The proposed development is consistent with the development criteria included in the Specific Plan. CONSIDERATIONS Required considerations in review of Architecture and Site applications: ■ As required by Section 29.20.150 of the Town Code, the considerations in review of an Architecture and Site application were all made in reviewing this project. Page 54 PLANNING COMMISSION – April 23, 2025 CONDITIONS OF APPROVAL 16511 Cypress Way Architecture and Site Application S-24-045 Consider a Request for Approval to Demolish an Existing Accessory Structure and Construct a New Accessory Structure Exceeding 1,000 square feet in Gross Floor Area and Site Improvements Requiring a Grading Permit on Property Zoned HR-2½. APN 532-24-004. Exempt Pursuant to the CEQA Section 15303(a): New Construction or Conversion of Small Structures. Property Owners: Jackie and Scott Kolander Applicant: Michael Harris Project Planner: Suray Nathan TO THE SATISFACTION OF THE COMMUNITY DEVELOPMENT DIRECTOR: Planning Division 1. APPROVAL: This application shall be completed in accordance with all of the conditions of approval and in substantial compliance with the approved plans. Any changes or modifications to the approved plans and/or business operation shall be approved by the Community Development Director, Development Review Committee, or the Planning Commission depending on the scope of the changes. 2. EXPIRATION: The approval will expire two years from the approval date pursuant to Section 29.20.320 of the Town Code, unless the approval has been vested. 3. OUTDOOR LIGHTING: Exterior lighting shall be kept to a minimum, and shall be down directed fixtures that will not reflect or encroach onto adjacent properties. No flood lights shall be used unless it can be demonstrated that they are needed for safety or security. 4. TREE REMOVAL PERMIT: A Tree Removal Permit shall be obtained for any trees to be removed, prior to the issuance of a building or grading permit. 5. EXISTING TREES: All existing trees shown on the plan and trees required to remain or to be planted are specific subjects of approval of this plan, and must remain on the site. 6. ARBORIST REQUIREMENTS: The developer shall implement, at their cost, all recommendations identified in the Arborist’s report for the project, on file in the Community Development Department. These recommendations must be incorporated in the building permit plans and completed prior to issuance of a building permit where applicable. 7. TREE FENCING: Protective tree fencing and other protection measures consistent with Section 29.10.1005 of the Town Code shall be placed at the drip line of existing trees prior to issuance of demolition and building permits and shall remain through all phases of construction. Include a tree protection plan with the construction plans. 8. TREE STAKING: All newly planted trees shall be double-staked using rubber tree ties. 9. FRONT YARD LANDSCAPE: Prior to issuance of a Certificate of Occupancy the front yard EXHIBIT 3 Page 55 must be landscaped. 10. WATER EFFICIENCY LANDSCAPE ORDINANCE: The final landscape plan shall meet the Town of Los Gatos Water Conservation Ordinance or the State Water Efficient Landscape Ordinance, whichever is more restrictive. A review fee based on the current fee schedule adopted by the Town Council is required when working landscape and irrigation plans are submitted for review. 11. PROJECT IDENTIFICATION SIGNAGE: Project identification signage on the project site shall be removed within 30 days of approval of the Architecture and Site application. 12. NESTING BIRDS: To avoid impacts to nesting birds, the removal of trees and shrubs shall be minimized to the greatest extent feasible. Construction activities that include any tree removal, pruning, grading, grubbing, or demolition shall be conducted outside of the bird nesting season (January 15 through September 15) to the greatest extent feasible. If this type of construction starts, if work is scheduled to start or if work already occurring during the nesting season stops for at least two weeks and is scheduled to resume during the bird nesting season, then a qualified biologist shall conduct a pre-construction surveys for nesting birds to ensure that no nests would be disturbed during project construction. If project-related work is scheduled during the nesting season (February 15 to August 30 for small bird species such as passerines; January 15 to September 15 for owls; and February 15 to September 15 for other raptors), a qualified biologist shall conduct nesting bird surveys. Two surveys for active nests of such birds shall occur within 14 days prior to start of construction, with the second survey conducted with 48 hours prior to start of construction. Appropriate minimum survey radius surrounding each work area is typically 250 feet for passerines, 500 feet for smaller raptors, and 1,000 feet for larger raptors. Surveys shall be conducted at the appropriate times of day to observe nesting activities. If the qualified biologist documents active nests within the project site or in nearby surrounding areas, an appropriate buffer between each nest and active construction shall be established. The buffer shall be clearly marked and maintained until the young have fledged and are foraging independently. Prior to construction, the qualified biologist shall conduct baseline monitoring of each nest to characterize “normal” bird behavior and establish a buffer distance, which allows the birds to exhibit normal behavior. The qualified biologist shall monitor the nesting birds daily during construction activities and increase the buffer if birds show signs of unusual or distressed behavior (e.g. defensive flights and vocalizations, standing up from a brooding position, and/or flying away from the nest). If buffer establishment is not possible, the qualified biologist or construction foreman shall have the authority to cease all construction work in the area until the young have fledged and the nest is no longer active. 13. SPECIAL-STATUS BATS: Approximately 14 days prior to tree removal or structure demolition activities, a qualified biologist shall conduct a habitat assessment for bats and potential roosting sites in trees to be removed, in trees within 50 feet of the development footprint, and within and surrounding any structures that may be disturbed by the project. These surveys will include a visual inspection of potential roosting features (bats need not be present) and a search for presence of guano within the project site, construction access routes, and 50 feet around these areas. Cavities, crevices, exfoliating bark, and bark fissures that could provide suitable potential nest or roost habitat for bats Page 56 shall be surveyed. Assumptions can be made on what species is present due to observed visual characteristics along with habitat use, or the bats can be identified to the species level with the use of a bat echolocation detector such as an “Anabat” unit. Potential roosting features found during the survey shall be flagged or marked. If no roosting sites or bats are found, a letter report confirming absence will be prepared and no further measures are required. If bats or roosting sites are found, a letter report and supplemental documents will be prepared prior to grading permit issuance and the following monitoring, exclusion, and habitat replacement measures will be implemented: a. If bats are found roosting outside of the nursery season (May 1 through October 1), they will be evicted as described under (b) below. If bats are found roosting during the nursery season, they will be monitored to determine if the roost site is a maternal roost. This could occur by either visual inspection of the roost bat pups, if possible, or by monitoring the roost after the adults leave for the night to listen for bat pups. If the roost is determined to not be a maternal roost, then the bats will be evicted as described under (b) below. Because bat pups cannot leave the roost until they are mature enough, eviction of a maternal roost cannot occur during the nursery season. Therefore, if a maternal roost is present, a 50-foot buffer zone (or different size if determined in consultation with the CDFW) will be established around the roosting site within which no construction activities including tree removal or structure disturbance will occur until after the nursery season. b. If a non-breeding bat hibernaculum is found in a tree or snag scheduled for removal or on any structures scheduled to be disturbed by project activities, the individuals will be safely evicted, under the direction of a qualified bat biologist. If pre-construction surveys determine that there are bats present in any trees to be removed, exclusion structures (e.g. one-way doors or similar methods) shall be installed by a qualified biologist. The exclusion structures shall not be placed until the time of year in which young are able to fly, outside of the nursery season. Information on placement of exclusion structures shall be provided to the CDFW prior to construction. If needed, other methods conducted under the direction of a qualified bat biologist could include: carefully opening the roosting area in a tree or snag by hand to expose the cavity and opening doors/windows on structures, or creating openings in walls to allow light into the structures. Removal of any trees or snags and disturbance of any structures will be conducted no earlier than the following day (i.e., at least one night will be provided between initial roost eviction disturbance and tree removal/structure disturbance). This action will allow bats to leave during dark hours, which increases their chance of finding new roosts with a minimum of potential predation. 14. ARCHAEOLOGICAL RESOURCES AND HUMAN REMAINS: a. In the event that archaeological traces are encountered, all construction within a 50- meter radius of the find will be halted, the Community Development Director will be Page 57 notified, and an archaeologist will be retained to examine the find and make appropriate recommendations. b. If human remains are discovered, the Santa Clara County Coroner will be notified. The Coroner will determine whether or not the remains are Native American. If the Coroner determines the remains are not subject to his authority, he will notify the Native American Heritage Commission, who shall attempt to identify descendants of the deceased Native Americans. c. If the Community Development Director finds that the archaeological find is not a significant resource, work will resume only after the submittal of a preliminary archaeological report and after provisions for reburial and ongoing monitoring are accepted. Provisions for identifying descendants of a deceased Native American and for reburial will follow the protocol set forth in CEQA Guidelines Section 15064.5( e). If the site is found to be a significant archaeological site, a mitigation program will be prepared and submitted to the Community Development Director for consideration and approval, in conformance with the protocol set forth in Public Resources Code Section 21083.2. d. A final report shall be prepared when a find is determined to be a significant archaeological site, and/or when Native American remains are found on the site. The final report will include background information on the completed work, a description and list of identified resources, the disposition and curation of these resources, any testing, other recovered information, and conclusions. 15. DUSKY-FOOTED WOODRATS: This project will implement the following standard measures to minimize impacts on woodrats and active woodrat nests on the project site. a. PRECONSTRUCTION SURVEY. A qualified biologist will conduct a preconstruction survey for San Francisco dusky-footed woodrat nests within 30 days of the start of work activities. If active woodrat nests are determined to be present in, or within 10 feet of the impact areas, the conditions below (Avoidance and/or Nest Relocation) will be implemented, as appropriate. If no active woodrat nests are present on or within 10 feet of impact areas, no further conditions are warranted. b. AVOIDANCE. Active woodrat nests that are detected within the work area will be avoided to the extend feasible. Ideally, a minimum 10-foot buffer will be maintained between project activities and woodrat nests to avoid disturbance. In some situations, a small buffer may be allowed if, in the opinion of a qualified biologist, nest relocation (below) would represent a greater disturbance to the woodrats than the adjacent work activities. c. NEST RELOCATION. If avoidance of active woodrat nests within and immediately adjacent to (within 10 feet of) the work areas is not feasible, then nest materials will be relocated to suitable habitat as close to the project site as possible (ideally, within or immediately adjacent to the project site). Relocation efforts will avoid the peak nesting season (February-July) to the maximum extent feasible. Prior to the start of construction activities, a qualified biologist will disturb the woodrat nest to the degree that all woodrats leave the nest and seek refuge outside of the construction area. Disturbance of the woodrat nest will be Page 58 initiated no earlier than one hour before dusk to prevent the exposure of woodrats to diurnal predators. Subsequently, the biologist will dismantle and relocate the nest material by hand. During the deconstruction process, the biologist will attempt to assess if there are juveniles in the nest. If immobile juveniles are observed, the deconstruction process will be discontinued until a time when the biologist believes the juveniles will be capable of independent survival (typically after 2 to 3 weeks). A no-disturbance buffer will be established around the nest until the juveniles are mobile. The nest may be dismantled once the biologist has determined that adverse impacts on the juveniles would not occur. 16. TOWN INDEMNITY: Applicants are notified that Town Code Section 1.10.115 requires that any applicant who receives a permit or entitlement (“the Project”) from the Town shall defend (with counsel approved by Town), indemnify, and hold harmless the Town, its agents, officers, and employees from and against any claim, action, or proceeding (including without limitation any appeal or petition for review thereof) against the Town or its agents, officers or employees related to an approval of the Project, including without limitation any related application, permit, certification, condition, environmental determination, other approval, compliance or failure to comply with applicable laws and regulations, and/or processing methods (“Challenge”). Town may (but is not obligated to) defend such Challenge as Town, in its sole discretion, determines appropriate, all at applicant’s sole cost and expense. Applicant shall bear any and all losses, damages, injuries, liabilities, costs and expenses (including, without limitation, staff time and in-house attorney’s fees on a fully-loaded basis, attorney’s fees for outside legal counsel, expert witness fees, court costs, and other litigation expenses) arising out of or related to any Challenge (“Costs”), whether incurred by Applicant, Town, or awarded to any third party, and shall pay to the Town upon demand any Costs incurred by the Town. No modification of the Project, any application, permit certification, condition, environmental determination, other approval, change in applicable laws and regulations, or change in such Challenge as Town, in its sole discretion, determines appropriate, all the applicant’s sole cost and expense. No modification of the Project, any application, permit certification, condition, environmental determination, other approval, change in applicable laws and regulations, or change in processing methods shall alter the applicant’s indemnity obligation. 17. COMPLIANCE MEMORANDUM: A memorandum shall be prepared and submitted with the building plans detailing how the Conditions of Approval will be addressed. Building Division 18. PERMITS REQUIRED: a. A demolition permit is required for the complete demolition of the existing detached garage. b. A Building Permit is required for the construction of a new detached garage and associated retaining walls. 19. APPLICABLE CODES: The current codes, as amended and adopted by the Town of Los Page 59 Gatos as of January 1, 2023, are the 2022 California Building Standards Code, California Code of Regulations Title 24, Parts 1-12. 20. CONDITIONS OF APPROVAL: The Conditions of Approval must be included on plan sheets within the construction plans. A Compliance Memorandum shall be prepared and submitted with the building permit application detailing how the Conditions of Approval will be addressed. 21. SIZE OF PLANS: Minimum size 24” x 36”, maximum size 30” x 42”. 22. SOILS REPORT: A Soils Report, prepared to the satisfaction of the Building Official, containing foundation, and retaining wall design recommendations, shall be submitted with the Building Permit Application. This report shall be prepared by a licensed Civil Engineer specializing in soils mechanics. 23. FOUNDATION INSPECTIONS: A pad certificate prepared by a licensed civil engineer or land surveyor shall be submitted to the project Building Inspector at foundation inspection. This certificate shall certify compliance with the recommendations as specified in the Soils Report, and that the building pad elevations and on-site retaining wall locations and elevations have been prepared according to the approved plans. Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered Civil Engineer for the following items: a. Building pad elevation b. Finish floor elevation c. Foundation corner locations d. Retaining wall(s) locations and elevations 24. HAZARDOUS FIRE ZONE: All projects in the Town of Los Gatos require Class A roof assemblies. 25. WILDLAND-URBAN INTERFACE: This project is located in a Wildland-Urban Interface High Fire Area and must comply with Section R337 of the 2022 California Residential Code, Public Resources Code 4291 and California Government Code Section 51182. a. Provide defensible space/fire break landscaping plan prepared by a California licensed Landscape Architect in conformance with California Public Resources Code 4291 and California Government Code Section 51182. b. Prior to final inspection, provide a letter from a California licensed Landscape Architect certifying the landscaping and vegetation clearance requirements have been completed per the California Public Resources Code 4291 and Government Code Section 51182. 26. SPECIAL INSPECTIONS: When a special inspection is required by CBC Section 1704, the Architect or Engineer of Record shall prepare an inspection program that shall be submitted to the Building Official for approval prior to issuance of the Building Permit. The Town Special Inspection form must be completely filled-out and signed by all requested parties prior to permit issuance. Special Inspection forms are available online at www.losgatosca.gov/building. 27. BLUEPRINT FOR A CLEAN BAY SHEET: The Town standard Santa Clara Valley Nonpoint Source Pollution Control Program Sheet (page size same as submitted drawings) shall be Page 60 part of the plan submittal. The specification sheet is available online at www.losgatosca.gov/building. 28. APPROVALS REQUIRED: The project requires the following departments and agencies approval before issuing a building permit: a. Community Development – Planning Division: (408) 354-6874 b. Engineering/Parks & Public Works Department: (408) 399-5771 c. Santa Clara County Fire Department: (408) 378-4010 d. Local School District: The Town will forward the paperwork to the appropriate school district(s) for processing. A copy of the paid receipt is required prior to permit issuance. TO THE SATISFACTION OF THE DIRECTOR OF PARKS & PUBLIC WORKS: Engineering Division 29. PAYMENT OF PARKS AND PUBLIC WORKS (“PPW”) ENGINEERING PLAN CHECK FEE AND INSPECTION FEE – At the time of the first construction submittal, the Applicant shall submit to the Town Engineer for approval a detailed construction project cost estimate prepared and stamped by the Applicant’s civil engineer. The cost estimate shall break out on-site and off-site improvements separately. This cost estimate will be used to determine the Engineering Plan Check Fee. A final construction cost estimate shall be provided once the project plans are approved. This cost estimate will be used to determine the Engineering Inspection Fee. The Engineering Inspection Fee must be paid prior to the issuance of any construction related permit. 30. CONSTRUCTION ACTITIVITIES MITIGATION FEE (ORDINANCE 2189) – Per the Town’s Comprehensive Fee Schedule, the project is subject to the Town’s Construction Activities Mitigation Fee based on the square footage of new buildings. The fee is $1.43 per square foot of new residential and non-residential building area. The fee shall be calculated based on the square footage total for all units shown on the construction plans to the approval of the Town Engineer. The project plans indicate the new building area of 1,239 SF resulting in a fee of $1,771.77. Payment of this fee shall pe paid prior to issuance of the first building permit. 31. GRADING PERMIT – A grading permit is required for all site grading and drainage work that is outside the perimeter of a building, retaining wall footing, or other structure authorized by a valid building permit. The Applicant must submit a grading permit application after the appeal period of the entitlement approval process has passed. Submittals are accepted through Accela only. The grading permit application shall include detailed grading plans and associated required materials. Plan check fees are based on the scope of onsite work. Prior to approval of the grading permit, the Applicant shall pay all fees due and provide faithful performance and payment securities for the performance of the work described and delineated on the approved grading plan, final erosion and sedimentation control plan, and interim erosion and sedimentation control plan (if required), in an amount to be set by the Town Engineer (but not to exceed one hundred (100) percent) of the approved estimated cost of the grading and erosion and Page 61 sedimentation control measures. The form of security shall be one or a combination of the following to be determined by the Town Engineer and subject to the approval of the Town Attorney: (1) Bond or bonds issued by one or more duly authorized corporate sureties on a form approved by the Town; (2) Deposit with the Town, money, or negotiable bonds of the kind approved for securing deposits of public monies; or (3) other instrument of credit from one or more financial institutions subject to regulation by the State or Federal Government wherein such financial institution pledges funds are on deposit and guaranteed for payment. The grading permit shall be issued prior to the issuance of the building permit unless otherwise allowed by the Town Engineer. The permit shall be limited to work shown on the grading plans approved by the Town Engineer. In granting a permit, the Town Engineer may impose any condition deemed necessary to protect the health, safety, and welfare of the public, to prevent the creation of a nuisance or hazard to public or private property, and to assure proper completion of the grading including but not limited to: (1) Mitigation of adverse environmental impacts; (2) Improvement of any existing grading or correction of any existing grading violation to comply with Town Code; (3) Requirements for fencing or other protection of grading which would otherwise be hazardous; (4) Requirements for dust, erosion, sediment, and noise control, hours of operation and season of work, weather conditions, sequence of work, access roads, and haul routes; (5) Requirements for safeguarding watercourses from excessive deposition of sediment or debris in quantities exceeding natural levels; (6) Assurance that the land area in which grading is proposed and for which habitable structures are proposed is not subject to hazards of land slippage or significant settlement or erosion and that the hazards of seismic activity or flooding can be eliminated or adequately reduced; (7) Temporary and permanent landscape plans. 32. TREE REMOVAL PERMIT – The Applicant shall apply and obtain a Tree Removal Permit from the Parks and Public Works Department for the removal of existing trees on-site or in the public right-of-way prior to the issuance of a building permit or demolition building permit, whichever is issued first. Tree removals shall be consistent with the arborist report and approved entitlement plans. 33. CONSTRUCTION PHASE PLAN SUBMITTAL REQUIREMENTS – The Grading Permit Plans (“Grading Plans”) shall be submitted to Parks and Public Works Department along with a title report dated no older than 30 days from the date the Grading Plans are submitted. The Grading Plans shall be submitted at the same time as the Building Plans are submitted to the Building Department. All improvements shall be designed and constructed in accordance with Federal law, State law, Los Gatos Town Code, and the Los Gatos Standard Specifications and Details. a. Construction drawings shall comply with Section 1 (Construction Plan Requirements) of the Town’s Engineering Design Standards, which are available for download from the Town’s website. The Grading Plans shall include: b. A cover sheet with at least the proposed development vicinity map showing nearby and adjacent major streets and landmarks, property address, APN, scope of work, project manager and property owner, a “Table of Responsibilities” summarizing ownership, access rights, and maintenance responsibilities for each facility (streets, utilities, parks, landscaping, etc.), a sheet index including a sequential numeric page Page 62 number for each sheet (i.e. “Sheet 1 of 54”), the lot size, required and proposed lot setbacks by type, proposed floor areas by type for each building, average slope, proposed maximum height, and required and proposed parking count and type. c. The Approved Conditions of Approval printed within the plan set starting on the second sheet of the plan set. d. An Existing Site Plan showing existing topography, bearing and distance information for all rights-of-way, easements, and boundaries, any existing easements proposed to be quit-claimed, existing hardscape, existing above ground utility features, and existing structures. The Grading Plans shall identify the vertical elevation datum, date of survey, and surveyor responsible for the data presented. e. A Proposed Site Plan showing proposed topography, boundaries, proposed and existing to remain easements, hardscape, above ground utility features (hydrants, transformers, control cabinets, communication nodes, etc.), and structures. Include top and bottom elevations of every inflection point of each proposed wall. Include utility details. Showing appropriate line types and labels to identify the different types of utilities and pipe sizes. Utility boxes, hydrants, backflow preventers, water meters, sanitary sewer cleanouts, etc. Distinguish proposed linework from existing linework using heavier line type for proposed. f. A Grading and Drainage Plan clearly showing existing onsite and adjacent topography using labeled contour lines, drainage direction arrows with slope value, and break lines. Proposed and existing to remain hardscape elevations must be provided in detail including slope arrows. g. A Landscaping Plan for the project site shall clearly identify public and private utilities and points of demarcation between the two. h. General Notes found in the Town of Los Gatos General Guidelines. i. A statement in the general notes indicating the need to obtain a Caltrans Oversized/Overweight Vehicles Transportation Permit if oversized or overweight vehicles are expected to be used 34. EXISTING FACILITY PROTECTION AND REPAIR – All existing public utilities shall be either protected in place, relocated, or repaired. The Applicant shall repair or replace all existing improvements not designated for removal, and all new improvements that are damaged during construction or removed because of the Applicant’s operations. This includes sidewalk, curb and gutter, streetlights, valley gutters, curb ramps, and any other existing improvements in the area that are not intended to be removed and replaced. The Applicant shall request a walk-through with the PPW construction Inspector before the start of construction to verify existing conditions. Said repairs shall be completed prior to issuance of the first certificate of occupancy of the project. 35. UTILITY RESPONSIBILITIES – The Applicant is responsible for all expenses necessary to connect to the various utility providers. Currently, the public storm sewer system is owned and maintained by the Town of Los Gatos, the water system in Los Gatos is owned and maintained by San José Water Company, and the sanitary sewer system in Los Gatos is owned and maintained by West Valley Sanitation District. Any alterations of the approved utilities listed must be approved by the Town prior to any construction. 36. DEVELOPER STORM WATER QUALITY RESPONSIBILITY – The Applicant is responsible for Page 63 ensuring that all contractors including subcontractors are aware of all stormwater quality measures and implement such measures. The Applicant shall perform all construction activities in accordance with approved Improvement Plans, Los Gatos Town Code Chapter 12 – Grading, Erosion and Sediment Control, and the National Pollutant Discharge Elimination System (NPDES) General Permit. Failure to comply with these rules and regulations will result in the issuance of correction notices, citations, or a project stop order. 37. SITE DRAINAGE – Rainwater leaders shall be discharged to splash blocks. No through curb drains will be allowed. No improvements shall obstruct or divert runoff to the detriment of an adjacent, downstream or down slope property. 38. OFF-SITE DRAINAGE – The Applicant shall not alter any existing drainage patterns without an approved Grading Permit. 39. GRADING & DRAINAGE WINTER MORATORIUM – All grading activity shall comply with the Municipal Regional Stormwater Permit and Chapter 12 of the Town Code. There shall be no earthwork disturbance or grading activities between October 15th and April 15th of each year unless approved by the Town Engineer. To be considered for approval, the Applicant must submit a Winterization Erosion Control Plan certified by a California certified QSD to the Town Engineer for review and approval. If grading is allowed during the rainy season, a maximum of two (2) weeks is allowed between clearing of an area and stabilizing/building on the exposed area. The submission of a certified plan does not guarantee approval. Any approved and executed plan must be kept on-site while the project is in construction. 40. EROSION CONTROL – The Applicant shall prepare and submit interim and final erosion control plans to the Town Engineer for review and approval. The interim erosion control plan(s) shall include measures carried out during construction before final landscaping is installed. Multiple phases of interim erosion control plans may be necessary depending on the complexity of the project. Interim erosion control best management practices may include silt fences, fiber rolls, erosion control blankets, Town approved seeding mixtures, filter berms, check dams, retention basins, etc. The Applicant shall install, maintain, and modify the erosion control measures as needed to continuously protect downstream water quality. In the event an emergency modification is deemed necessary, the Applicant must implement necessary measures to protect downstream waterways immediately and then submit the changes made within 24-hours to the Town Engineer for review and approval. The erosion control plans shall follow applicable measures contained in the most current Santa Clara County National Pollutant Discharge Elimination System (NPDES) Municipal Regional Permit (MRP). Any fees or penalties assessed against the Town in response to the Applicant’s failure to comply with the Permit must be paid by the Applicant. The Applicant must permit Town staff onsite to conduct periodic NPDES inspections throughout the recognized storm season to verify compliance with the Construction General Permit and Stormwater ordinances and regulations. 41. GEOTECHNICAL REVIEW – Prior to building permit issuance, the Applicant’s Geotechnical Engineer shall submit a design level geotechnical report. The report will require a peer review by the Town’s geological and geotechnical consultant. A deposit and fee for the peer review will be required per the Town’s current fee schedule, unless there are any Page 64 remaining deposit funds from the entitlement phase. The Town will route the design level geotechnical report to the Town’s peer review consultant once the report is submitted and deposit and fee are available. Once approved, the geotechnical engineer shall review the grading and drainage plan and proposed pavement and foundation design to verify that the design is in accordance with their recommendations. The Applicant’s Geotechnical Engineer’s approval shall be conveyed to the Town either by letter or by signing and stamping the plans. All grading operations and soil compaction activities shall be per the approved project’s design level geotechnical report. The Applicant shall add this condition to the general notes on the grading plan. 42. GEOTECHNICAL ENGINEER OBSERVATION – All grading activities shall be conducted under the observation of, and tested by, a licensed geotechnical engineer. A report shall be filed with the Town of Los Gatos for each phase of construction stating that all grading activities were performed in conformance with the requirements of the project’s design level geotechnical report. The Applicant shall submit a Final Geotechnical Construction Observation and Testing Summary in an “as-built” letter/report prepared and submitted to the Town prior to issuance of the certificate of occupancy. The Applicant shall add this condition to the general notes on the grading plan. 43. PRECONSTRUCTION MEETING – After the issuance of any Grading or Encroachment permit and before the commencement of any on or off-site work, the Applicant shall request a pre-construction meeting with the PPW Inspector to discuss the project conditions of approval, working hours, site maintenance, and other construction matters. At that meeting, the Applicant shall submit a letter acknowledging each of the following: a. They have read and understand these project Conditions of Approval. b. They will require that all project sub-contractors read and understand these project Conditions of Approval. c. They will post a copy of these project Conditions of Approval on-site and ensure the posting always remains intact during construction. THE FOLLOWING CONDITIONS SHALL BE MET PRIOR TO RELEASE OF UTILITIES, FINAL INSPECTION, OR ISSUANCE OF A CERTIFICATE OF OCCUPANCY, WHICHEVER OCCURS FIRST, OR IF ANOTHER DEADLINE IS SPECIFIED IN A CONDITION, AT THAT TIME. 44. RESTORATION OF PUBLIC IMPROVEMENTS – The Applicant shall repair or replace all existing improvements not designated for removal that are damaged or removed during construction. Improvements such as, but not limited to curbs, gutters, sidewalks, driveways, signs, streetlights, pavements, raised pavement markers, thermoplastic pavement markings, etc., shall be repaired or replaced to a condition equal to or better than the original condition. Any new concrete shall be free of stamps, logos, names, graffiti, etc. Existing improvement to be repaired or replaced shall be at the direction of the PPW Inspector and shall comply with all Title 24 Disabled Access provisions. The restoration of all improvements identified by the PPW Inspector shall be completed before the issuance of a certificate of occupancy. The Applicant shall request a walk- through with the PPW Inspector before the start of construction to verify existing Page 65 conditions. THE FOLLOWING CONDITIONS SHALL BE COMPLIED WITH AT ALL TIMES DURING THE CONSTRUCTION PHASE OF THE PROJECT, OR IF ANOTHER DEADLINE IS SPECIFIED IN A CONDITION, AT THAT TIME 45. PROJECT CONSTRUCTION SETUP – All storage and office trailers will be kept off the public right-of-way. 46. PUBLIC WORKS CONSTRUCTION NOTICE – The contractor shall notify the PPW Inspector at least ten (10) working days prior to the start of any construction work. At that time, the Contractor shall provide an initial project construction schedule and a 24-hour emergency telephone number list. 47. PROJECT CONSTRUCTION SCHEDULE – The contractor shall submit the project schedule in a static PDF 11”x17” format and Microsoft Project, or an approved equal. The Contractor shall identify the scheduled critical path for the installation of improvements to the approval of the Town Engineer. The schedule shall be updated monthly and submitted to the PPW Inspector in the same formats as the original. 48. PROJECT CONSTRUCTION HANDOUT – The Contractor shall provide to the Town Engineer for approval a construction information handout for the purpose of responding to questions the Town receives regarding the project construction (one- or two-page document). 49. PROJECT CONSTRUCTION SUPERVISION – The Contractor shall always provide a qualified supervisor on the job site during construction. 50. PUBLIC WORKS CONSTRUCTION INSPECTION – All work shown on the Improvement Plans shall be inspected to the approval of the Town Engineer. Uninspected work shall be removed as deemed appropriate by the Town Engineer. 51. PROJECT CONSTRUCTION HOURS – Construction activities related to the issuance of any PPW permit shall comply with Town Code Section 16.20.035 which restricts construction to the weekday between 8:00 a.m. and 6:00 p.m. and Saturday 9:00 a.m. to 4:00 p.m. No work shall be done on Sundays or on Town Holidays unless otherwise approved by the Town Engineer. Please note that no work shall be allowed to take place within the Town right-of-way after 5:00 p.m. Monday through Friday. In addition, no work being done under Encroachment Permit may be performed on the weekend unless prior approvals have been granted by the Town Engineer. The Town Engineer may apply additional construction period restrictions, as necessary, to accommodate standard commute traffic along arterial roadways and along school commute routes. Onsite project signage must state the project construction hours. The permitted construction hours may be modified if the Town Engineer finds that the following criteria is met: a. Permitting extended hours of construction will decrease the total time needed to complete the project without an unreasonable impact to the neighborhood. b. Permitting extended hours of construction is required to accommodate a construction requirement such as a large concrete pour or major road closure. Such a need would be presented by the project's design engineer and require approval of the Town Engineer. Page 66 c. An emergency exists where the construction work is necessary to correct an unsafe or dangerous condition resulting in obvious and eminent peril to public health and safety. If such a condition exists, the Town may waive any of the remaining requirements outlined below. d. The exemption will not conflict with any other condition of approval required by the Town to mitigate significant environmental impacts. e. The contractor or property owner will notify residential and commercial occupants of adjacent properties of the modified construction work hours. This notification must be provided three days prior to the start of the extended construction activity. f. The approved hours of construction activity will be posted at the construction site in a place and manner that can be easily viewed by any interested member of the public. g. The Town Engineer may revoke the extended work hours at any time if the contractor or owner of the property fails to abide by the conditions of extended work hours or if it is determined that the peace, comfort, and tranquility of the occupants of adjacent residential or commercial properties are impaired because of the location and nature of the construction. h. The waiver application must be submitted to the PPW Inspector ten (10) working days prior to the requested date of waiver. 52. PROJECT CONSTRUCTION BMPs – All construction activities shall conform to the latest requirements of the CASQA Stormwater Best Management Practices Handbooks for Construction Activities and New Development and Redevelopment, the Town's grading and erosion control ordinances, the project specific temporary erosion control plan, and other generally accepted engineering practices for erosion control as required by the Town Engineer when undertaking construction activities. 53. PROJECT CONSTRUCTION EXCAVATION – The following provisions to control traffic congestion, noise, and dust shall be followed during site excavation, grading, and construction: a. All construction vehicles should be properly maintained and equipped with exhaust mufflers that meet State standards. b. Travel speeds on unpaved roads shall be limited to fifteen (15) miles per hour. c. Blowing dust shall be reduced by timing construction activities so that paving and building construction begin as soon as possible after completion of grading, and by landscaping disturbed soils as soon as possible. d. Water trucks shall be present and in use at the construction site. All portions of the site subject to blowing dust shall be watered as often as deemed necessary by the Town, or a minimum of three times daily, or apply (non-toxic) soil stabilizers on all unpaved access roads, parking areas, and staging areas at construction sites to ensure proper control of blowing dust for the duration of the project. e. Watering on public streets and wash down of dirt and debris into storm drain systems is prohibited. Streets will be cleaned by street sweepers or by hand as often as deemed necessary by the PPW Inspector, or at least once a day. Watering associated with on-site construction activity shall take place between the hours of 8 a.m. and 5 p.m. and shall include at least one late-afternoon watering to minimize Page 67 the effects of blowing dust. Recycled water shall be used for construction watering to manage dust control where possible, as determined by the Town Engineer. Where recycled water is not available potable water shall be used. All potable construction water from fire hydrants shall be coordinated with the San José Water Company. f. All public streets soiled or littered due to this construction activity shall be cleaned and swept daily during the workweek to the satisfaction of the Construction Inspector. g. Construction grading activity shall be discontinued in wind conditions more than 25 miles per hour, or that in the opinion of the PPW Inspector cause excessive neighborhood dust problems. h. Site dirt shall not be tracked into the public right-of-way and shall be cleaned immediately if tracked into the public right-of-way. Mud, silt, concrete and other construction debris shall not be washed into the Town’s storm drains. i. Construction activities shall be scheduled so that paving and foundation placement begin immediately upon completion of grading operation. j. All aggregate materials transported to and from the site shall be covered in accordance with Section 23114 of the California Vehicle Code during transit to and from the site. k. Prior to issuance of any permit, the Applicant shall submit any applicable pedestrian or traffic detour plans to the satisfaction of the Town Engineer for any lane or sidewalk closures. The temporary traffic control plan shall be prepared by a licensed professional engineer with experience in preparing such plans and in accordance with the requirements of the latest edition of the California Manual on Uniform Traffic Control Devices (MUTCD) and standard construction practices. The Traffic Control Plan shall be approved prior to the commencement of any work within the public right-of-way. l. During construction, the Applicant shall make accessible any or all public and private utilities within the area impacted by construction, as directed by the Town Engineer. m. The minimum soils sampling and testing frequency shall conform to Chapter 8 of the Caltrans Construction Manual. The Applicant shall require the soils engineer submit to daily testing and sampling reports to the Town Engineer. 54. MATERIAL HAULING ROUTE AND PERMIT – For material delivery vehicles equal to, or larger than two-axle, six-tire single unit truck size as defined by FHWA Standards, the Applicant shall submit a truck hauling route that conforms to Town of Los Gatos Standards for approval. Note that the Town requires a Haul Permit be issued for any hauling activities. The Applicant shall require contractors to prohibit trucks from using “compression release engine brakes” on residential streets. The haul route for this project unless otherwise approved by the Town Engineer, shall be Cypress Way to Loma Alta Avenue to Los Gatos Boulevard to Los Gatos-Saratoga Road to Highway 17. A letter from the Applicant confirming the intention to use the designated haul route shall be submitted to the Town Engineer for review and approval prior to the issuance of any Town permits. All material hauling activities including but not limited to, adherence to the approved route, hours of operation, staging of materials, dust control and street Page 68 maintenance shall be the responsibility of the Applicant. Hauling of soil on- or off-site shall not occur during the morning or evening peak periods (between 7:00 a.m. and 9:00 a.m. and between 4:00 p.m. and 6:00 p.m.), and at other times as specified by the Town Engineer. The Applicant must provide an approved method of cleaning tires and trimming loads on site. All material hauling activities shall be done in accordance with applicable Town ordinances and conditions of approval. 55. PROJECT CLOSE-OUT – Prior to requesting a Final Inspection, the Applicant shall submit to the Town Engineer a letter indicating that all project conditions have been met, and all improvements are complete. All work must be completed to the satisfaction of the Planning Director and Town Engineer prior to the first occupancy. All public improvements, including the complete installation of all improvements relative to streets, fencing, storm drainage, underground utilities, etc., shall be completed and attested to by the Town Engineer before approval of occupancy of any unit. Where facilities of other agencies are involved, including those for water and sanitary sewer services, such installation shall be verified as having been completed and accepted by those agencies. In addition, the Applicant shall submit an itemized final quantities list of all public improvements constructed on-site and within the public right-of-way. The final quantities list shall be prepared by the project engineer and be to the approval of the Town Engineer. The final quantities list shall be broken out into on-site and off-site improvements based on the format provided by the Town. Until such time as all required improvements are fully completed and accepted by Town, the Applicant shall be responsible for the care, maintenance, and any damage to such improvements. Town shall not, nor shall any officer or employee thereof, be liable or responsible for any accident, loss or damage, regardless of cause, happening or occurring to the work or improvements required for this project prior to the completion and acceptance of the work or Improvements. All such risks shall be the responsibility of and are hereby assumed by the Applicant. 56. CONSTRUCTION WORKER PARKING – The Applicant shall provide a Construction Parking Plan that minimizes the effect of construction worker parking in the neighborhood and shall include an estimate of the number of workers that will be present on the site during the various phases of construction and indicate where sufficient off-street parking will be utilized and identify any locations for off-site material deliveries. Said plan shall be approved by the Town Engineer prior to issuance of Town permits and shall be complied with at all times during construction. Failure to enforce the parking plan may result in suspension of the Town permits. No vehicle having a manufacturer's rated gross vehicle weight exceeding ten thousand (10,000) pounds shall be allowed to park on the portion of a street which abuts property in a residential zone without prior approval from the Town Engineer (§15.40.070). 57. SITE WATER DISCHARGE – In accordance with the Town Code, Prohibition of Illegal Discharges (Los Gatos Town Code Section 22.30.015), the Town Engineer may approve in coordination West Valley Sanitation District the discharge of uncontaminated pumped ground waters to the sanitary sewer only when such source is deemed unacceptable by State and Federal authorities for discharge to surface waters of the United States, whether pretreated or untreated, and for which no reasonable alternative method of Page 69 disposal is available. Following the verification of the applicable local, state and/or federal approvals, a Discharge Plan will be approved and monitored by the Town Engineer. THE FOLLOWING CONDITIONS SHALL BE COMPLIED WITH AT ALL TIMES THAT THE USE PERMITTED BY THIS ENTITLEMENT OCCUPIES THE PREMISES 58. POST CONSTRUCTION BEST MANAGEMENT PRACTICES (BMP) – Post construction storm water pollution prevention requirements shall include: a. The Applicant shall be charged the cost of abatement for issues associated with, but not limited to, inspection of the private stormwater facilities, emergency maintenance needed to protect public health or watercourses, and facility replacement or repair if the treatment facility is no longer able to meet performance standards or has deteriorated. Any abatement activity performed on the Applicant’s property by Town staff will be charged to the Applicant at the Town’s adopted fully loaded hourly rates. b. Maintenance of the storm drain inlets “No Dumping – Drains to Bay” plaques to alert the public to the destination of storm water and to prevent direct discharge of pollutants into the storm drain. Template ordering information is available at www.flowstobay.org. c. All process equipment, oils, fuels, solvents, coolants, fertilizers, pesticides, and similar chemical products, as well as petroleum-based wastes, tallow, and grease planned for storage outdoors shall be always stored in covered containers. d. All public outdoor spaces and trails shall include installation and upkeep of dog waste stations. e. Garbage and recycling receptacles and bins shall be designed and maintained with permanent covers to prevent exposure of trash to rain. Trash enclosure drains shall be connected to the sanitary sewer system. f. It is the responsibility of the property owner(s)/homeowners association to implement a plan for street sweeping of paved private roads and cleaning of all storm drain inlets. TO THE SATISFACTION OF THE SANTA CLARA COUNTY FIRE DEPARTMENT: 59. GENERAL: Review of this Developmental proposal is limited to acceptability of site access, water supply and may include specific additional requirements as they pertain to fire department operations, and shall not be construed as a substitute for formal plan review to determine compliance with adopted model codes. Prior to performing any work, the applicant shall make application to, and receive from, the Building Department all applicable construction permits. 60. VERY HIGH FIRE HAZARD SEVERITY ZONE (VHFHSZ): The subject property is located within the Very High Fire Hazard Severity Zone (VHFHSZ) of the Local Responsibility Area (LRA). Pursuant to California Public Resources Code (PRC) 4290, the California Board of Forestry and Fire Protection is required to" ... adopt regulations implementing minimum fire safety standards related to defensible space" applicable to "the perimeters and access to all Page 70 residential, commercial, and industrial building construction." In 2018, the Legislature passed and the Governor signed SB 901 (Dodd), which expanded the applicability of the regulations promulgated under PRC 4290 to land in the Local Responsibility Area (LRA) Very High Fire Hazard Severity Zone. All comments below that result from PRC 4290 are identified by**. Where a conflict exists between local & 4290 requirements, the more stringent requirement shall apply. California Code of Regulations, Title 14, Division 1.5, Chapter 7, Subchapter 2, Articles 1-5, § 1273.08 61. FIRE SPRINKLERS REQUIRED: Approved automatic sprinkler systems in new and existing buildings and structures shall be provided in the locations described in this Section or in Sections 903.2.1 through 903.2.12 whichever is the more restrictive and Sections 903.2.14 through 903.2.21. For the purposes of this section, firewalls and fire barriers used to separate building areas shall be constructed in accordance with the California Building Code and shall be without openings or penetrations. Fire sprinklers proposed in new garage as part of the AMMR condition PC 25-0417. Make a note on coversheet that a AMMR is included in this project. A copy of the approved Alternate Means/Methods application form (with approval signature), justification letter, and these comments shall be made part of all subsequent submittals (Building, planning, etc.), to be routed to Santa Clara County Fire Department for final approval. 62. PRIVATE FIRE PROTECTION SYSTEM: Residential fire protection systems shall comply with Fire Department Standards W-1 and manufacturer's requirements. Fire protection water systems shall be submitted for review and approval by SCCFD prior to installation. The wharf hydrant shall be accessible at all times. Tank systems providing both the domestic supply and supply to the sprinkler system and/or hydrant may require cross contamination protection. Check with the local Building Department for specific requirements related to protection of the domestic supply. New 5000 gallon water tanks noted on Sheet A1.1. Make a note on coversheet that private fire protection system will be provided as part of the approved AMMR condition. Sign shall be posted on the wharf hydrant indicating it is supplied by a 5,000 gallon tank. 63. FIRE HYDRANT SYSTEMS REQUIRED: Where a portion of the facility or building hereafter constructed or moved into or within the jurisdiction is more than 400 feet from a hydrant on a fire apparatus access road, as measured by an approved route around the exterior of the facility or building, onsite fire hydrants and mains shall be provided where required by the fire code official. Exception: For Group R-3 and Group U occupancies, equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3, the distance requirement shall be not more than 600 feet. [CFC, Section 507.5.1] Show wharf hydrant and vehicle impact protection bollard on plans as part of the approved AMMR condition. Sign shall be posted on the wharf hydrant indicating it is supplied by a 5,000 gallon tank. 64. CONSTRUCTION SITE FIRE SAFETY: All construction sites must comply with applicable provisions of the CFC Chapter 33 and our Standard Detail and Specification S1-7. Provide appropriate notations on subsequent plan submittals, as appropriate to the project. CFC Chp. 33. Page 71 65. NOTE: This review shall not be construed to be an approval of a violation of the provisions of the California Fire Code or of other laws or regulations of the jurisdiction. A permit presuming to give authority to violate or cancel the provisions of the fire code or other such laws or regulations shall not be valid. Any addition to or alteration of approved construction documents shall be approved in advance. [CFC, Ch.1, 105.3.6] Page 72 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com PROJECT DESCRIPTION Town of Los Gatos Community Development Department 110 E. Main Street | Los Gatos, CA 95031 www.losgatosca.gov Plan Check: S-24-045 Architecture and Site Development Application Address: 16511 Cypress Way | Los Gatos, CA Description: Garage & Breezeway Replacement Summary of Project The proposed project is to replace an existing single-story two-car garage of 587 square feet and shed of 96 square feet with a new single-story three-car garage of 1,239 square feet. The new garage will be in the same location and the maximum height at the ridge line is 15’-0” above the foundation level. In addition, the existing breezeway will be replaced in the same location. There is minimal impact to the surrounding areas and properties. The proposed design falls within the regulations of the hillside development standards and matches the aesthetic of the existing residence. EXHIBIT 4 Page 73 2 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com County of Santa Clara Fire Department The site is located in a very high fire hazard severity zone (VHFHSZ), the Fire Department requires the following. Fire Apparatus Road – minimum width of 20 feet width 13 feet 6 inches vertical clearance. The section of Cypress Way from the main section to the residence is a 12-foot wide country road about 0.325 miles (1,750 feet) with significant barriers to accommodate a 20-foot minimum width such as existing residences along with inclines and declines at the cross sections that would require significant retaining walls, removal of several trees/foliage and possibly eminent domain in order to achieve. This is an extremely expensive compliance item and is significantly disproportionate to the total cost of the project. In turn, an alternate materials and methods of construction application has been filed with the County of Santa Clara Fire Department for mitigations. Please refer to the Wildland Urban Interface Compliance section of this Project Justification for details. Driveway entrance to accommodate a turning radius of 50 feet outside and 30 feet inside with a maximum slope of 15%. Slopes at the driveway exceed 15% and turning radii currently does not exist on the property without significant demolition, grading, paving and retaining walls in order to achieve. Alternatively, providing a turnout along Cypress Way resulting in significant retaining walls at the front portion of the property. The added cost would be disproportionate to the total cost of the entire project without this element. In turn, an alternate materials and methods of construction application has been filed with the County of Santa Clara Fire Department for mitigations. Please refer to the Wildland Urban Interface Compliance section of this Project Justification for details. Page 74 3 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com Fire hydrant within 400 feet of the property line located on a fire apparatus road along the front approach to the property or 600 feet if fully sprinklered. The nearest fire hydrant along the front approach of the property is located approximately 1,975’ away to the west. This would require routing a 6” water line along a road with minimal clearance. The cost and feasibility of installing such a line along with a fire hydrant will be significantly disproportionate to the cost of the entire project. An alternate materials and methods of construction application has been filed with and approved by the County of Santa Clara Fire Department to include installation of NFPA 13D fire sprinklers in the garage only (not main residence), 2-hour fire-barrier between the garage and breezeway for a fire break and installation of a 5,000 gallon fire water storage polyethylene tank of approximately 10-foot diameter by 9-feet 4-inches tall on site and connected to a wharf hydrant at the front of the property. Fire department (engine) driveway turnaround of 40 feet. The existing area at the top of the driveway does not accommodate a 40-foot radius turnaround. The current turnaround space is 16-foot radius. Significant modifications and retaining walls would be required in order to achieve this. The added cost would be disproportionate to the total cost of the entire project without this element. In turn, an alternate materials and methods of construction application has been filed with and approved by the County of Santa Clara Fire Department for mitigations. Wildland Urban Interface Compliance There are several Wildland Urban Interface compliance items being implemented into the project. In the end, the garage will be safer and more ignition resistant than before the project. The following items are being incorporated into the project. Exterior cladding - ignition resistant materials - stucco Roof materials - Class A asphalt roof tiles Closed eaves Ember resistant soffit vents Ember resistant ridge vents Ember resistant gable-end vents Metal-cladded door assemblies with tempered windows Windows double-paned and tempered All doors have perimeter weather stripping and door bottoms to reduce ember intrusion Page 75 4 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com Vegetation management & defensible breaks Zone 0 (5'-0") will be concrete on the back of the garage, asphalt in the front of the garage, mostly existing pavement on the west side and concrete or rock-line swale on the east. There is a 3' section that a rock-gravel surface may be added to ensure no landscaping. Also removing 2 trees currently next to structure. Zone 1 (30'-0") - existing trees to remain unless removed due to grading; owner to maintain ground cover to remove dead weeds. Canopies elevated to at least 6’-0” clear from the ground. Zone 2 (100'-0") - existing trees to remain unless removed due to grading; no proposed further modifications. Alternate Materials and Methods of Construction (AMMC): In Lieu of the following items: • Fire apparatus access roadway clearances – street width of 20’-0” clear by 13’-6” high – actual road is 12’-0” wide and doesn’t achieve height requirements • Fire department driveway turnaround clearance – driveway area does not accommodate 40’ minimum outside turning radius. • Fire hydrant distance within 400’ or 600’ if fully sprinklered – actual fire hydrant is approx. 1,975’ away from the property line. The following is being proposed due to the scale of the project. Please note that this approach has been discussed with the County Fire Department and is part of the AMMC application process, which has been approved under SCCFD 25-0417. • NFPA 13D fire sprinkler system in garage structure only. The main residence will remain unsprinklered. Also, include a 2-hour fire-barrier wall assembly at garage between breezeway • 5,000 gallon fire water storage polyethylene tank (no pump) located at least 10’-0” from garage structure with 4” diameter underground water line and connection to a new wharf fire hydrant located at the northeasterly corner of the property adjacent to the driveway access. Impact protection bollards are set between the hydrant and driveway to prevent accidental damage. Signage is posted on the wharf hydrant indicating it is supplied by a 5,000 gallon tank. • Address directional and identification signage visible from the approaching corner (east corner) of Cypress Way where the road splits in two directions. Page 76 5 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com Compliance with Zoning Code Project Data Occupancy R-3/U Type of Construction: V-B Sprinklered (Main Residence): No Sprinklered (Garage): Yes, NFPA 13D Stories: One APN: 532-24-004 Zoning: HR-2½ Site Area: (1.257 acres) 54,624.24 sqft. (Single-family dwelling unit) Average Lot Slope: ~32% Reduction on net site area on sloping lots (60%) 21,849.60 sqft. Existing House Area: 2,377 sqft. Removed Accessory Area (Detached Garage): 587 sqft. Removed Accessory Area (Shed): 96 sqft. Added Accessory Area (Detached Garage): 1,239 sqft. Proposed Building Accessory Height: 15’-0” Allowed Maximum Accessory Height: 15’-0” Floor Area Ratio: 19.83% Allowed Maximum Floor Area Ratio: Table 2 (Hillside Development Standards & Guidelines) 4,900 sqft. Resident Parking: 3 covered Guest Parking: 4 uncovered Project Area: 1,239 sqft. Page 77 6 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com HR-2 ½ Zone: 2 ½ to 10 acres for each dwelling unit Actual site area: 1.257 acres Permitted uses Single-family dwelling (no more than 1 principle residential structure per lot) Actual use – one single-family dwelling Minimum lot area: 40,000 sqft. Actual lot area: 54,624.24 sqft. Minimum lot width: 100’-0” Actual lot width: 320’-3” Maximum height for accessory building: 15’-0” Proposed accessory building height: 15’-0” Landscaping is required in yards abutting scenic roads. Existing vegetation shall be left in a natural state. Existing landscaping in front along Cypress Way is to remain undisturbed and is more of a natural state. Page 78 7 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com Compliance with Hillside Development Standards & Guidelines Chapter II – Constraints Analysis and Site Selection Site selection and constraint analysis • Site is already developed for this project. • LRDA – there are some areas on site where the topography exceeds 30%. Site plan illustrates the specific locations for LRDA exceeding 30% and the project area is located outside of this boundary • Vegetation is intended to remain natural. Any grading per the civil plans restore terrain back to its natural state to match existing • Drainage courses – project accommodates existing drainage into rock swales along the side of the driveway. Reference civil plans for further detail • Septic systems – the main house already has a septic system and the location is well outside of the project area. There are no plumbing fixtures nor hose bibbs being installed as part of this project so the septic system remains unchanged • Geologic constraints – identified on the soils report for the foundation and associated grading. Grading is highlighted on the civil plans. The retaining wall design and garage foundation design will be based upon the recommendations of the geotechnical engineer in the soils report and submitted as part of the building plan check process. • Wildlife habitats and movement corridors – the project is expected to have minimal or no impact on the existing wildlife. As part of the conditions of approval, a biologist will investigate and provide a report. Construction activity to adhere to the established restrictions to support any possible habitat • Visibility from off the site – low visibility due to structure being under the 18’ constraint established in the Hillside Development Standards. • Areas of severe fire danger – site is located in very high fire hazard severity zone (VHFHSZ); Wildland Urban Interface provisions implemented into the project (see compliance section in this document) • Solar orientation and prevailing wind patterns – site is already established including garage location. The project maintains the existing solar orientation and prevailing wind patterns. • Significant Ridgelines – the site is located down from any significant ridgeline and the scale of the accessory building is below the 18’ constraint established in the Hillside Development Standards. Consultation with Neighbors • There are two other residences on the section of Cypress Way near the project area. Property owners have discussed with both residents in detail about the project. Visibility Analysis • A visibility analysis is not required since the project is involving only a residential accessory structure at 15’ high which is less than the 18’ constraint referenced in the Town of Los Gatos Hillside Development Standards and Guidelines. Page 79 8 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com Chapter III – Site Planning Grading – reference civil drawings for further information. Maximum grade cuts are based upon the existing terrain, preserving natural features and drainage and utilizing the existing garage location. Note that the garage foundation level is being maintained in the addition thus the noted maximum cut noted in the garage line item. A request for exemption is requested due to existing conditions on site. The garage is maintaining the same pad elevation as the existing removed. Due to the existing site configuration and constraints, cutting an additional 5.5’ is necessary to maintain the same pad elevation. Elevating the garage would require significantly more grading and asphalt modifications. The same is true for the additional 7’ of cut for the miscellaneous hardscape and additional 3’ of cut for the landscaping. Drainage – Project utilizes existing drainage into rock swales along the side of the driveway. Reference civil plans for further detail Driveway – no proposed modifications to the existing driveway. Driveways are at least 12’ wide, however do not accommodate the 3’ shoulder in all areas. The slope exceeds 15% with the average slope at 22%. Driveway is fully paved. Parking – there are 3 covered parking spaces for the residents and 4 uncovered parking spaces for guests Geologic hazards – identified on the soils report for the foundation and associated grading. Grading is highlighted on the civil plans. The retaining wall design and garage foundation design will be based upon the recommendations of the geotechnical engineer in the soils report and submitted as part of the building plan check process. Fire hazards – site is located in very high fire hazard severity zone (VHFHSZ); Wildland Urban Interface provisions implemented into the project (see compliance section in this document) Chapter IV – Development Intensity Maximum allowable developement – project is in compliance per Table 2 Page 80 9 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com Chapter V – Architectural Design The colors, textures and materials will match the primary structure. The scale of the structure is within zoning height limitations and complies with the Hillside Development Standards. Exterior cladding – stucco to match the existing house Roofing – asphalt shingles in the same style and color as the existing house Introduction of dormers to provide architectural features that are in harmony with the natural environment and breaks up the standard gable blandness. The mass is fairly subtle especially with the limited height to 15’-0”. Scale of the project maintains low to no visual impact to the neighbors. Placement on the site supports compatibility with the immediate neighborhood context Sustainability – comply with provisions of the California Green Building Code for residential measures. Implementation of wildland urban interface features Chapter VI – Site Elements The use of new retaining walls are limited to 5-feet high are of split-faced CMU matching existing split- faced CMU retaining walls already established on site. New retaining walls will also blend with the natural topography and follow natural drainage paths. The length of the longest proposed site retaining wall at the rear of the garage is approximately 74-feet. As part of the noted 74-foot length, there is a 4-foot section at the stair assembly then a straight run along the south without a break is 40-feet then a run of 30-feet perpendicular to the east of the garage. This complies with the maximum 50-foot retaining wall straight run limitation. Outdoor lighting is to be subtle and maintain existing established styles. Outdoor lighting is very minimal on this project (replacement of garage fixtures) and will comply with CALGreen requirements for light cut- off and meet CA Title 24 requirements. Chapter VII – Landscape Design Compliance with Wildland Urban Interface defensible space guidelines. See section for further description for attributes. Any land disturbance will be restored for natural landscaping to match existing. As part of the project trees will be removed in the area of project impact and partially to address defensible space guidelines. Tree removal is necessary to accommodate the new garage size with the grading and drainage required. The Town’s Arborist report identifies 4 trees to be removed, however this was based upon the original submittal before comments were received. The resubmittal has shown a total of 8 trees to be removed in order to comply with the requirements in the Hillside Development Standards for retaining walls limited to 5-foot high and WUI (Wildland Urban Interface) requirements through AMMC (25-0417). The site is located in a very high fire hazard severity zone (VHFHSZ). Tree replacement is not being proposed due to WUI requirements as planting new trees will result in a greater fire hazard than the original condition, especially when the trees are fully mature. Tree canopies in Zone 1 shall not touch in order to accommodate a reasonable fire break. Planting any new tree would not accommodate this. In-lieu fees are being requested instead of planting any new trees. Page 81 10 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com Compliance with Residential Design Guidelines The colors, textures and materials will match the primary structure. The scale of the structure is within zoning height limitations and complies with the Hillside Development Standards. Other attributes are discussed further in detail in the section above including architectural style, height, bulk, scale, roofs, windows, materials, architectural features, privacy, sustainable design and fire-life safety. An exemption has been requested for the LRV exceeding 30 since the intent for the proposed garage assembly is to have the same materials, textures and colors to match the existing residence for what is already established on site. Compatibility with Immediate Neighborhood Context The project scale is a single-story accessory structure that is limited to 15’-0” high. The materials, colors and textures match the existing residence and by nature are already compatible with the neighborhood context consisting of single-family residences. Massing has minimal impact as shown in the site section below. Page 82 11 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com Materials, colors and texture The colors, textures and materials will match the primary structure. Exterior cladding is stucco and will match the main residence Roof is asphalt shingle tiles and will match the main residence Trim, gutters and facia will match the main residence Doors will match the stucco color Lattice and breezeway wall will match the existing nearby bbq terrace Page 83 This Page Intentionally Left Blank Page 84 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com REQUEST FOR EXEMPTION Town of Los Gatos Community Development Department 110 E. Main Street | Los Gatos, CA 95031 www.losgatosca.gov Plan Check: S-24-045 Architecture and Site Development Application Address: 16511 Cypress Way | Los Gatos, CA Description: Garage & Breezeway Replacement LRV Exceeding 30 The colors, textures and materials will match the primary structure. The scale of the structure is within zoning height limitations and complies with the Hillside Development Standards. Other attributes are discussed further in detail in the section above including architectural style, height, bulk, scale, roofs, windows, materials, architectural features, privacy, sustainable design and fire-life safety. An exemption has been requested for the LRV exceeding 30 since the intent for the proposed garage assembly is to have the same materials, textures and colors to match the existing residence for what is already established on site. The colors, textures and materials will match the primary structure. Exterior cladding is stucco and will match the main residence Roof is asphalt shingle tiles and will match the main residence Trim, gutters and facia will match the main residence Doors will match the stucco color Lattice and breezeway wall will match the existing nearby bbq terrace EXHIBIT 5 Page 85 2 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com Cut and Fill Exceeding Maximum Allowed Maximum grade cuts are based upon the existing terrain, preserving natural features and drainage and utilizing the existing garage location. Note that the garage foundation level is being maintained in the addition thus the noted maximum cut noted in the garage line item. A request for exemption is requested due to existing conditions on site. The garage is maintaining the same pad elevation as the existing removed. Due to the existing site configuration and constraints, cutting an additional 5.5’ is necessary to maintain the same pad elevation. Elevating the garage would require significantly more grading and asphalt modifications. The same is true for the additional 7’ of cut for the miscellaneous hardscape and additional 3’ of cut for the landscaping. Page 86 3 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com Page 87 4 3360 De La Cruz Blvd. | Santa Clara, CA 95054 | 408-648-4500 | CA Lic 443949 | www.ba-builders.com Additional Trees Removed & In Lieu Fee Request Tree removal is necessary to accommodate the new garage size with the grading and drainage required. The Town’s Arborist report identifies 4 trees to be removed, however this was based upon the original submittal before comments were received. The resubmittal has shown a total of 8 trees to be removed in order to comply with the requirements in the Hillside Development Standards for retaining walls limited to 5-foot high and WUI (Wildland Urban Interface) requirements through AMMC (25-0417). The site is located in a very high fire hazard severity zone (VHFHSZ). Tree replacement is not being proposed due to WUI requirements as planting new trees will result in a greater fire hazard than the original condition, especially when the trees are fully mature. Tree canopies in Zone 1 shall not touch in order to accommodate a reasonable fire break. Planting any new tree would not accommodate this. In-lieu fees are being requested instead of planting any new trees. Page 88 September 17, 2024 Mr. Suray NathanCommunity Development DepartmentTown of Los Gatos110 E. Main StreetLos Gatos, CA 95031 RE: 16511 Cypress Way Dear Suray: I reviewed the drawings and evaluated the neighborhood context. My comments and recommendations on the design are as follows: NEIGHBORHOOD CONTEXT The site is located in a hillside neighborhood with heavy mature landscaping and large lots and homes. Photos of the site and its surrounding neighborhood are shown on the following page. EXHIBIT 6Page 89 16511 Cypress Way Design Review Comments September 17, 2024 Page 2 House below this site THE SITE CONTEXT View from below up to site THE SITE CONTEXT Page 90 16511 Cypress Way Design Review Comments September 17, 2024 Page 3 PROPOSED PROJECT Proposed site plan Proposed Floor Plan Proposed Front Elevation Existing garage and breezeway Proposed Cross Section at dormers Proposed Side Elevation Proposed Longitudinal Section Page 91 16511 Cypress Way Design Review Comments September 17, 2024 Page 4 ISSUES AND RECOMMENDATIONS The proposed project is a replacement of an existing garage and breezeway. It is modest in size and design. It proposes roof dormer windows which are characteristics of carriage house but perfectly acceptable as windows bringing natural light into the garage interior. The area is well shielded by landscaping from views of any adjacent neighbors. I have no recommendations for changes. Suray, please let me know if you have any questions or if there are any issues that I did not address. Sincerely, CANNON DESIGN GROUP Larry L. Cannon Page 92 Tree Inventory, Assessment, and Protection Report 16511 Cypress Way Los Gatos, CA 95032 Prepared for: Town of Los Gatos November 6, 2024 Prepared By: EXHIBIT 7Page 93 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Table of Content Summary ...............................................................................................................1 Introduction ...........................................................................................................1 Background ............................................................................................................1 Assignment .............................................................................................................1 Limits of the assignment ........................................................................................1 Purpose and use of the report ................................................................................2 Observations .........................................................................................................2 Tree Inventory .........................................................................................................2 Analysis .................................................................................................................4 Discussion .............................................................................................................5 Condition Rating .....................................................................................................5 Mitigation for Removals ..........................................................................................6 Expected Impacts ...................................................................................................7 Tree Protection .......................................................................................................8 Conclusion ............................................................................................................8 Recommendations ...............................................................................................9 Bibliography ........................................................................................................10 Glossary of Terms ...............................................................................................11 Appendix A: Tree Inventory, Site Plan, and Protection ....................................13 Appendix B: Tree Inventory and Assessment Tables ......................................14 Appendix C: Photographs ..................................................................................15 Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page 94 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 C1: Trees #616, #623 and #624 ............................................................................15 C2: Trees #617, #618, and #619 ...........................................................................16 C3: Holly #615 ......................................................................................................17 Appendix D: Tree Protection Guidelines ...........................................................18 D1: Plan Sheet Detail S-X (Type I) ........................................................................18 D2: Plan Sheet Detail S-Y (Type III) ......................................................................19 D3: Section 29.10.1005. - Protection of Trees During Construction ....................20 Tree Protection Zones and Fence Specifications .................................................20 All persons, shall comply with the following precautions .....................................21 Prohibited Activities ..............................................................................................21 Monitoring ............................................................................................................22 Root Pruning .........................................................................................................22 Boring or Tunneling ...............................................................................................22 Tree Pruning and Removal Operations .................................................................22 Appendix E: Tree Protection Signs ....................................................................23 E1: English ............................................................................................................23 E2: Spanish ...........................................................................................................24 Qualifications, Assumptions, and Limiting Conditions ...................................25 Certification of Performance.............................................................................26 Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page 95 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Summary The applicant is requesting approval for construction of accessory structures exceeding 1,000 square feet in gross floor area and site improvements on property zoned HR-2 1/2. APN 532-24-004. Exempt pursuant to the CEQA Section 15303(a): new construction or conversion of small structures. The inventory contains ten (10) trees comprised of seven (7) different species. There are no Large Protected, Exempt, or Street Trees. Seven trees are in good condition and the remaining three are in fair shape. One pine tree #619 has signs of red turpentine beetles (Dendroctonus valens). Four trees are expected to be highly impacted and removed which included holly #615 (Ilex aquifolium) Chinese pistache (Pistacia chinensis) #617, coast live oak (Quercus agrifolia) #618, and silk tree (Albizia julibrissin) #624. One tree, coast live oak #623, could be moderately impacted. The remaining five trees are not expected to be affected. Tree protection will consider of fence around those to remain at their calculated tree protection radius of eight times their trunk diameter in feet. The applicant will be required to replace four protected trees. There were ten (10) protected trees appraised for a rounded depreciated value of $17,690.00. Introduction Background The Town of Los Gatos asked me to assess the site, trees, and proposed footprint plan, and to provide a report with my findings and recommendations to help satisfy planning requirements. Assignment •Provide an arborist’s report including an assessment of the trees within the project area and on the adjacent sites. The assessment is to include the species, size (trunk diameter), condition (health, structure, and form), and suitability for preservation ratings. Affix number tags on the trees for reference on site and on plans. •Provide tree protection specifications, guidelines, and impact ratings for those affected by the project. •Provide appraised values using the Trunk Formula Technique. Limits of the assignment •The information in this report is limited to the condition of the trees during my inspection on October 22, 2024. No tree risk assessments were performed. •Tree heights and canopy diameters are estimates. Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 1 26 Page 96 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 •The plans reviewed for this assignment were as follows (Table 1). Purpose and use of the report The report is intended to identify all the trees within the plan area that could be affected by a project. The report is to be used by the Town of Los Gatos and the property owners as a reference for existing tree conditions to help satisfy planning requirements. Observations Tree Inventory The inventory consists of trees protected by the Town of Los Gatos located on site and those in close proximity on neighboring properties. Sec. 29.10.0960. - Scope of protected trees. All trees which have a four-inch or greater diameter (twelve and one half-inch circumference) of any trunk, when removal relates to any review for which zoning approval or subdivision approval is required. (Appendix A and B). Los Gatos Town Ordinance 29.10.0970 Exceptions (1) states the following: “A fruit or nut tree that is less than eighteen (18) inches in diameter (fifty-seven-inch circumference). Table 1: Plans Reviewed Checklist Plan Date Sheet Reviewed Source Existing Site Topographic Proposed Site Plan July 2024 A1.1 Yes Bay Area Builders, Inc. Erosion Control Grading and Drainage July 2024 C1 Yes R.I. Engineering Inc. Utility Plan and Hook-up locations Exterior Elevations July 2024 A3.1 - A3.3 Yes Bay Area Builders, Inc. Landscape Plan Irrigation Plan T-1 Tree Protection Plan Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 2 26 Page 97 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 The inventory contains ten (10) trees comprised of seven (7) different species. There are no Large Protected , Exempt , or Street 1 2 Trees (Chart 1). 3 Large protected tree means any oak (Quercus spp.), California buckeye (Aesculus californica), or Pacific madrone (Arbutus menziesii) which has a 24-inch or 1 greater diameter (75-inch circumference); or any other species of tree with a 48-inch or greater diameter (150-inch circumference). A fruit or nut tree that is less than eighteen (18) inches in diameter (fifty-seven-inch circumference). Species listed in 29.10.0970 subsection (2).2 Street tree means a tree in a public place, or along or within a public street or right-of-way.3 Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 3 26 Quantity Page 98 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Analysis Tree appraisal was performed according to the Council of Tree & Landscape Appraisers Guide for Plant Appraisal 10th Edition, 2019 (CLTA) along with Western Chapter International Society of Arboriculture Species Classification and Group Assignment, 2004. The trees were appraised using the “Cost Approach” and more specifically the “Trunk Formula Technique” (Appendix B). “Trunk Formula Technique” is calculated as follows: Basic Tree Cost = (Unit tree cost x Appraised trunk area), Appraised Value = (Basic tree cost X functional Limitations (percentage) X Condition (percentage) X External Limitations (percentage)). The trunk formula valuations are based on four tree factors; size (trunk cross sectional area), condition, functional limitations, and external limitations. There are two steps to determine the overall value. The first step is to determine the “Basic Tree Cost” based on size and unit tree cost. Unit tree cost is calculated by dividing the nursery wholesale cost of a 24 inch box specimen and its replacement size (cost per square inch trunk caliper) which is determined by the Species Classification and Group Assignment, 2004 Western Chapter Regional Supplement. The cost of the 24 inch box wholesale specimen was determined through personal communications with BrightView and Normans nurseries in Farmington and Central Wholesale in San Jose for an average of $214.00. The second part is to depreciate the tree’s Basic Cost through an assessment of condition, functional limitations, and external limitations. The condition assessment guidelines and percentages are defined in the “Condition Rating” section of this report. Functional limitations are based on factors associated with the tree’s interaction to its planting site that would affect condition, limit development, or reduce the utility in the future and include genetics, placement, and site conditions for the individual tree. External limitations are outside the property, out of control of the owner and also affect condition, limit development, or reduce the utility in the future (i.e power lines, municipal restrictions, drought adaptations, or species susceptibility to pests). There were ten (10) protected trees appraised for a rounded depreciated value of $17,690.00. Appraisal worksheets are available upon request. Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 4 26 Page 99 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Discussion Condition Rating A tree’s condition is a determination of its overall health, structure, and form. The assessment considered all three criteria for a combined condition rating. •100% - Exceptional = Good health and structure with significant size, location or quality. •61-80% - Good = Normal vigor, well-developed structure, function and aesthetics not compromised with good longevity for the site. •41-60 % - Fair = Reduced vigor, damage, dieback, or pest problems, at least one significant structural problem or multiple moderate defects requiring treatment. Major asymmetry or deviation from the species normal habit, function and aesthetics compromised. •21-40% - Poor = Unhealthy and declining appearance with poor vigor, abnormal foliar color, size or density with potential irreversible decline. One serious structural defect or multiple significant defects that cannot be corrected and failure may occur at any time. Significant asymmetry and compromised aesthetics and intended use. •6-20% - Very Poor = Poor vigor and dying with little foliage in irreversible decline. Severe defects with the likelihood of failure being probable or imminent. Aesthetically poor with little or no function in the landscape. •0-5% - Dead/Unstable = Dead or imminently ready to fail. Seven trees are in good condition and the remaining three are in fair shape. One pine tree #619 has signs of red turpentine beetles (Dendroctonus valens) (Chart 2). Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 5 26 Quantity Page 100 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Mitigation for Removals The table below indicates the recommended replacement values (Table 2). The applicant will be required to replace four protected trees. Alternatively it may be possible to create an approved landscape plan or provide an in-lieu payment. The landscape plan does not indicate any replacement trees. 1To measure an asymmetrical canopy of a tree, the widest measurement shall be used to determine canopy size. 2Often, it is not possible to replace a single large, older tree with an equivalent tree(s). In this case, the tree may be replaced with a combination of both the Tree Canopy Replacement Standard and in-lieu payment in an amount set forth by Town Council resolution paid to the Town Tree Replacement Fund. 3Single Family Residential Replacement Option is available for developed single family residential lots under 10,000 square feet that are not subject to the Town’s Hillside Development Standards and Guidelines. All 15-gallon trees must be planted on-site. Any in-lieu fees for single family residential shall be based on 24” box tree rates as adopted by Town Council. 4Replacement Trees shall be approved by the Town Arborist and shall be of a species suited to the available planting location, proximity to structures, overhead clearances, soil type, compatibility with surrounding canopy and other relevant factors. Replacement with native species shall be strongly encouraged. Replacement requirements in the Hillsides shall comply with the Hillside Development Standards and Guidelines Appendix A and Section 29.10.0987 Special Provisions—Hillsides. Table 2: Town of Los Gatos Tree Canopy - Replacement Standard Canopy Size of Removed Tree (1) Replacement Requirement (2)(4) Single Family Residential Replacement Option (3)(4) 10 feet or less Two 24 inch box trees Two 15 gallon trees More than 10 feet to 25 feet Three 24 inch box trees Three 15 gallon trees More than 25 feet to 40 feet Four 24 inch box trees or two 36 inch box trees Four 15 gallon trees More than 40 feet to 55 feet Six 24 inch box trees; or three 36 inch box trees Not available Greater than 55 feet Ten 24 inch box trees; or five 36 inch box trees Not available Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 6 26 Page 101 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Expected Impacts Impact level defines how a tree may be affected by construction activity and proximity to the tree, and is described as low, moderate, or high. The following scale defines the impact rating: •Low = The construction activity will have little influence on the tree. •Moderate = The construction may cause future health or structural problems, and steps must be taken to protect the tree to reduce future problems. •High = Tree structure and health will be compromised and removal is recommended, or other actions must be taken for the tree to remain. The tree is located in the building envelope. Four trees are expected to be highly impacted and removed which included holly #615, Chinese pistache #617, coast live oak #618, and silk tree #624 (Chart 3). One tree, coast live oak #623, could be moderately impacted and one of its codominant stems will need to be removed to provide clearance (and as a byproduct improve overall structure). The remaining five trees are not expected to be affected. Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 7 26 Quantity Page 102 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Tree Protection Typically there are three different tree protection schemes which are called Type I (Appendix D1), Type II and Type III (Appendix D2) trunk protection only. The tree protection zone (TPZ) is the defined area in which certain activities are prohibited to minimize potential injury to the tree. There are two tree protection zones determined which include the “calculated” and “specified”. The “calculated” tree protection zone is determined by a multiplication factor based on species tolerance, tree age/vigor/health, and trunk diameter. The “specified” tree protection zone is adjusted in size and shape to accommodate the existing infrastructure, planned construction, and specific site constraints. This “specified” zone includes tree canopy conformation, visible root orientation, size, condition, maturity, and species tolerances (Gilpin, R, Hauer, R, Matheny, N, and Smiley, E.T. 2023). Tree protection will consider of fence around those to remain at their calculated tree protection radius of eight times their trunk diameter in feet. Conclusion The inventory contains ten (10) trees comprised of seven (7) different species. There are no Large Protected, Exempt, or Street Trees. Seven trees are in good condition and the remaining three are in fair shape. One pine tree #619 has signs of red turpentine beetles (Dendroctonus valens). Four trees are expected to be highly impacted and removed which included holly #615, Chinese pistache #617, coast live oak #618, and silk tree #624. One tree, coast live oak #623, could be moderately impacted and one of its codominant stems will need to be removed to provide clearance (and as a byproduct improve overall structure). The remaining five trees are not expected to be affected. Tree protection will consider of fence around those to remain at their calculated tree protection radius of eight times their trunk diameter in feet. The applicant will be required to replace four protected trees. There were ten (10) protected trees appraised for a rounded depreciated value of $17,690.00. Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 8 26 Page 103 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Recommendations 1.Provide a plan sheet or existing topographic survey that indicates the trees within the project area. None of the plan sheets show tree locations for #616, #617, #618, #623 or #624 which many are expected to be highly impacted (Appendix A). 2.Place tree protection fence around the trees to be retained as indicated in Appendix B “Calculated TPZ”. 3.All tree maintenance and care shall be performed by a qualified arborist with a C-61/D-49 California Contractors License. Tree maintenance and care shall be specified in writing according to American National Standard for Tree Care Operations: Tree, Shrub and Other Woody Plant Management: Standard Practices parts 1 through 10 and adhere to ANSI Z133.1 safety standards and local regulations. All maintenance is to be performed according to ISA Best Management Practices. 4.Refer to Appendix D for general tree protection guidelines including recommendations for arborist assistance while working under trees, trenching, or excavation within a trees drip line or designated TPZ/CRZ. 5.Place all the tree protection fence locations and guidelines on the plans including the grading, drainage, and utility plans. Create a separate plan sheet that includes all three protection measures labeled “T-1 Tree Protection Plan.” 6.Provide a copy of this report to all contractors and project managers, including the architect, civil engineer, and landscape designer or architect. It is the responsibility of the owner to ensure all parties are familiar with this document. Arrange a pre-construction meeting with the project arborist or landscape architect to verify tree protection is in place, with the correct materials, and at the proper distances. Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 9 26 Page 104 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Bibliography Gilpin, R, Hauer, R, Matheny, N, and Smiley, E.T. Managing trees during construction, Third edition. Champaign, IL: International Society of Arboriculture, 2023. ISA. Guide For Plant Appraisal 9th Edition. Savoy, IL: International Society of Arboriculture, 2000. Print. ISA. Guide For Plant Appraisal 10th Edition. Savoy, IL: International Society of Arboriculture, 2018. Print. ISA. Species Classification and Group Assignment, 2004 Western Chapter Regional Supplement. Western Chapter ISA Matheny, Nelda P., Clark, James R. Trees and development: A technical guide to preservation of trees during land development. Bedminster, PA: International Society of Arboriculture 1998. Smiley, E, Matheny, N, Lilly, S, ISA. Best Management Practices: Tree Risk Assessment: International Society of Arboriculture, 2017. Print Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 10 26 Page 105 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Glossary of Terms calculated tree protection zone: A TPZ calculated using the trunk diameter and a multiplication factor based on species tolerance to construction and tree age. It is often plotted on a plan as a circle or other arbitrary shape and can be used as a guide for establishing the specified TPZ. critical root zone: a conceptual soil area containing the minimal amount of all the essential parts of the root zone needed to sustain tree health and structural integrity. There are no universally accepted methods to calculate the CRZ. basic Tree Cost: The cost of replacement for a perfect specimen of a particular species and cross sectional area prior to location and condition depreciation. cost Approach: An indication of value by adding the land value to the depreciated value of improvements. defect: An imperfection, weakness, or lack of something necessary. In trees defects are injuries, growth patterns, decay, or other conditions that reduce the tree’s structural strength. diameter at breast height (DBH): Measures at 1.4 meters (4.5 feet) above ground in the United States, Australia (arboriculture), New Zealand, and when using the Guide for Plant Appraisal, 9th edition; at 1.3 meters (4.3 feet) above ground in Australia (forestry), Canada, the European Union, and in UK forestry; and at 1.5 meters (5 feet) above ground in UK arboriculture. drip Line: Imaginary line defined by the branch spread or a single plant or group of plants. The outer extent of the tree crown. form: Describes a plant’s habit, shape or silhouette defined by its genetics, environment, or management. health: Assessment is based on the overall appearance of the tree, its leaf and twig growth, and the presence and severity of insects or disease mechanical damage: Physical damage caused by outside forces such as cutting, chopping or any mechanized device that may strike the tree trunk, roots or branches. Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 11 26 Page 106 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 scaffold branches: Permanent or structural branches that for the scaffold architecture or structure of a tree. specified tree protection zone (specified TPZ): a TPZ that is adjusted in size or shape to accommodate the existing infrastructure, planned construction, and aspects of the site, as well as the tree canopy conformation, visible root orientation, size, condition, maturity, and species response to construction. straw wattle: also known as straw worms, bio-logs, straw noodles, or straw tubes are man made cylinders of compressed, weed free straw (wheat or rice), 8 to 12 inches in diameter and 20 to 25 feet long. They are encased in jute, nylon, or other photo degradable materials, and have an average weight of 35 pounds. structure: Evaluation focused on the crown, trunk, trunk flare, above ground roots and the site conditions contributing to conditions and/or defects that may contribute to failure. Tree Protection Zone (TPZ): Defined area within which certain activities are prohibited or restricted to prevent or minimize potential injury to designated trees, especially during construction or development. Tree Risk Assessment: Process of evaluating what unexpected things could happen, how likely it is, and what the likely outcomes are. In tree management, the systematic process to determine the level of risk posed by a tree, tree part, or group of trees. trunk: Stem of a tree. Trunk Formula Technique: Method to appraise the monetary value of trees considered too large to be replaced with nursery or field grown stock. Based on developing a representative unit cost for replacement with the same or comparable species of the same size and in the same place, subject to depreciation for various factors. Contrast with replacement cost method. volunteer: A tree, not planted by human hands, that begins to grow on residential or commercial property. Unlike trees that are b drought in and installed on property, volunteer trees usually spring up on their own from seeds placed onto the ground by natural causes or accidental transport by people. Normally, volunteer trees are considered weeds and removed, but many desirable and attractive specimens have gone on to become permanent residents on many public and private grounds. Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 12 26 Page 107 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Appendix A: Tree Inventory, Site Plan, and Protection Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 13 26 #615 #616 #617 #618 #619 #620 #621 #622 #623 #624 Page 108 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Appendix B: Tree Inventory and Assessment Tables Table 3: Inventory and Assessment Summary Tree Species I.D. #Trunk Diameter (in.) ~ Canopy Diameter (ft.) Condition Expected Impact Protection Status Rounded Depreciated Value Calculated Protection Radii (ft.) holly (Ilex aquifolium)615 10 15 Good High Protected $1,160.00 7 coast live oak (Quercus agrifolia)616 11 15 Good Low Protected $2,530.00 7 pistache (Pistacia chinensis)617 4 10 Good High Protected $570.00 3 coast live oak (Quercus agrifolia)618 4 10 Good High Protected $330.00 3 Canary Island pine (Pinus canariensis)619 14 15 Fair Low Protected $2,270.00 9 Canary Island pine (Pinus canariensis)620 17, 17 25 Fair Low Protected $6,700.00 16 black pine (Pinus jeffreyi)621 8 15 Good Low Protected $740.00 5 Monterey pine (Pinus radiata)622 19 20 Fair Low Protected $480.00 13 coast live oak (Quercus agrifolia)623 9, 7 10 Good Moderate Protected $2,720.00 8 Silk tree (Albizia julibrissin)624 9 10 Good High Protected $190.00 6 Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 14 26 Page 109 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Appendix C: Photographs C1: Trees #616, #623 and #624 Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 15 26 #616#624 #623 Page 110 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 C2: Trees #617, #618, and #619 Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 16 26 #617 #618#619 Page 111 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 C3: Holly #615 Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 17 26 #615 Page 112 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Appendix D: Tree Protection Guidelines D1: Plan Sheet Detail S-X (Type I) Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 18 26 TREE PROTECTION Crown drip line or other limit of Tree Protection area. See tree preservation plan for fence alignment.4'-0"Maintain existing grade with the tree protection fence unless otherwise indicated on the plans. 2" x 6' steel posts or approved equal. Tree Protection fence: High density polyethylene fencing with 3.5" x 1.5" openings; Color- orange. Steel postsinstalled at 8' o.c. 5" thick layer of mulch. Notes: 1- See specifications for additional treeprotection requirements. 2- If there is no existing irrigation, see specifications for watering requirements. 3- No pruning shall be performed except by approved arborist. 4- No equipment shall operate inside the protective fencing including during fence installation and removal. 5- See site preparation plan for any modifications with the Tree Protectionarea. SECTION VIEW KEEP OUT TREE PROTECTION AREA 8.5" x 11" signlaminated in plastic spacedevery 50' along the fence. URBAN TREE FOUNDATION © 2014OPEN SOURCE FREE TO USE Tree protection fence: Fencing shall be comprised of six- foot high chain link mounted on eight- foot tall, 1 7/8-inch diameter galvanized posts, driven 24 inches into the ground. Minimum 4” thick mulch layer Crown diameter drip line distance equal to the outer most limit of foliage.Notes: •All tree maintenance and care shall be performed by a qualified arborist with a C-61/D-49 California Contractors License. Tree maintenance and care shall be specified in writing according to American National Standard for Tree Care Operations: Tree, Shrub and Other Woody Plant Management: Standard Practices parts 1 through 10 and adhere to ANSI Z133.1 safety standards and local regulations. •All maintenance is to be performed according to ISA Best Management Practices. Notes: The Tree Protection Zone (TPZ) may vary in radius from the trunk and may or may not be established at the drip line distance. See arborist’s report and plan sheet for specifications of TPZ radii.6’-0”Modified by Monarch Consulting Arborists LLC, 2019 Page 113 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 D2: Plan Sheet Detail S-Y (Type III) Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 19 26EVCHARGINGONLYEVCHARGINGONLYNOPARKINGNOPARKINGCLEAN AIRVAN POOLE.V.CLEAN AIRVAN POOLE.V.CLEAN AIRVAN POOLE.V.327 328 329329327328E1E1E1E5E5AE5CC ?W ?W ?WPLANTING PLAN BYJONI JANECKI & ASSOCIATESSEE LIBRARY PLANS GUSHEE STREET PLANTING PLAN BYJONI JANECKI & ASSOCIATESSEE LIBRARY PLANSPLANTING PLAN BYJONI JANECKI & ASSOCIATESSEE LIBRARY PLANSPARKING AND BUILDING BYTEALL MESSER ARCHITECTSEE LIBRARY PLANSPLANTING PLAN BYJONI JANECKI & ASSOCIATESSEE LIBRARY PLANSLIBRARY LANDSCAPE PLAN BYJONI JANECKI & ASSOCIATES L.O.W.L.O.W.L.O.W.L.O.W.L.O.W.L.O.W.L.O.W.L.O.W.L.O.W.L.O.W.L.O.W.L.O.W.BULL CREEK FLOWLINEFUTURELIBRARY XXXXXXXXXXXXXXXXX X X X X X X X X X X KIRBY STREETXXXSEE L2.0 MATERIALS PLAN FOR DISCOVERY PARKIMPROVEMENTSSEE L2.0 MATERIALS PLAN FOR DISCOVERY PARKIMPROVEMENTS (E) CHAINLINK FENCE AND GATETO REMAIN APPROXIMATE LIMIT OF WORK (L.O.W.)LEGEND (E) TREE TO BE PROTECTED(E) TREE TO REMAINNOTE:1.SEE C3.0 EROSION CONTROL PLAN FOR TREEPROTECTION IN EXISTING RIPARIAN AREA.2.TREE SURVEY PROVIDED BY IFLAND SURVEY, 10/09/18.3.CONTRACTOR SHALL PROTECT ALL TREES WHICH ARELOCATED WITHIN 10' OF EQUIPMENT MOVEMENT.1L1.0(E) FENCE TO BE REMOVEDARBORIST NOTES:1.ALL TREE MAINTENANCE AND CARE SHALL BEPERFORMED BY A QUALIFIED ARBORIST WITH AC-61/D-49 CALIFORNIA CONTRACTORS LICENSE. TREEMAINTENANCE AND CARE SHALL BE SPECIFIED INWRITING ACCORDING TO AMERICAN NATIONALSTANDARD FOR TREE CARE OPERATIONS: TREE, SHRUBAND OTHER WOODY PLANT MANAGEMENT: STANDARDPRACTICES PARTS 1 THROUGH 10 AND ADHERE TO ANSIZ133.1 SAFETY STANDARDS AND LOCAL REGULATIONS.ALL MAINTENANCE IS TO BE PERFORMED ACCORDING TO ISA BEST MANAGEMENT PRACTICES. 2.TREE PRUNING - IF TREE PRUNING FOR OVERHEAD CLEARANCE IS REQUIRED OR NECESSARY PRUNING SPECIFICATIONS SHALL BE IN WRITING PRIOR TO ANY CUTTING. CUTTING SHALL BE PERFORMED BY A QUALIFIED TREE CARE PROFESSIONAL OR SUPERVISED BY THE PROJECT ARBORIST. NO LIMBS GREATER THAN FOUR INCHES (4”) IN DIAMETER SHALL BE REMOVED WITHOUT APPROVAL. 3.ROOT MANAGEMENT - PRIOR TO REMOVING ROOTS GREATER THAN TWO INCHES (2”) IN DIAMETER EACH TREE SHALL BE EVALUATED BY THE PROJECT ARBORIST TO HELP DETERMINE ITS LIKELIHOOD OF FAILURE AFTER ROOT LOSS. IF ROOTS OVER TWO INCHES IN DIAMETER ARE ENCOUNTERED THEY SHOULD BE PRUNED BY HAND WITH LOPPERS, HANDSAW, RECIPROCATING SAW, OR CHAIN SAW RATHER THAN LEFT CRUSHED OR TORN. ROOTS SHOULD BE CUT BEYOND SINKER ROOTS OR OUTSIDE ROOT BRANCH JUNCTIONS AND BE SUPERVISED BY THE PROJECT ARBORIST. WHEN COMPLETED, EXPOSED ROOTS SHOULD BE KEPT MOIST WITH BURLAP OR BACKFILLED WITHIN ONE HOUR. NO ROOTS SHALL BE CUT WITHIN SIX TIMES THE TRUNK DIAMETER DISTANCE IN FEET ON ONE SIDE WITHOUT ARBORIST APPROVAL. 4.TRUNK PROTECTION - PREVENTING MECHANICAL DAMAGE TO THE MAIN STEMS FROM EQUIPMENT OR HAND TOOLS CAN BE ACCOMPLISHED BY WRAPPING THE MAIN STEM WITH STRAW WATTLE. 5.SITE OCCUPANCY - HAVE A QUALIFIED ARBORIST PERFORM A LEVEL 2: BASIC TREE RISK ASSESSMENT AS DESCRIBED IN BEST MANAGEMENT PRACTICES: TREE RISK ASSESSMENT: INTERNATIONAL SOCIETY OF ARBORICULTURE, 2017 TO HELP IDENTIFY ANY NEW RISK FACTORS AFTER CONSTRUCTION UPON NEW SITE OCCUPANCY. DEMOLITION AND TREE PROTECTION PLAN L1.0 1"= 20' LANDSCAPE ARCHITECTBASE LANDSCAPE ARCHITECTUREPROJECT TEAMPROJECT NAME & ADDRESSFELTON LIBRARYDISCOVERY PARKGUSHEE STREETFELTON, CA, 95018REVISION#Date Description STAMP SHEET TITLE Scale: Date: Drawn by: Checked by: Project No.: PHASE BID SET No. 5579 Ren. 9/30/2020LICENSED A R C HI TECTST ATEOF CAL I F O R NIAAL ENDACSP 1802 PA / AS NM 04/19/2019 CIVIL ENGINEERMME CIVIL + STRUCTURAL ENGINEERINGSAN FRANCISCO / PORTLANDwww.baselandscape.comIRRIGATION DESIGNRMA IRRIGATIONCLIENTSANTA CRUZ COUNTY DEPARTMENT OF PARKS,OPEN SPACE, AND CULTURAL SERVICES 0 feet40 1" = 20' 20 60 80 NORTHSECTION TREE TRUNK 12" Ø STRAWFILLED BURLAPWATTLES TREE PROTECTION WITHOUT FENCE 3/8" = 1'-0"4'-0"ROOT PROTECTIONZONE. SEE SPECS FORREQUIREMENTS 1 SCHEDULE TREES TO BE PROTECTED: 20 TREES TO BE REMOVED: 0 04-19-20191 Planning Review Comments1 SECTION VIEW TRUNK PROTECTION WITH WATTLES-Y 6’-0” Excavation Trenches: 1. When any roots are cut or torn during construction, it is critical that you sharply cut all the ends of any exposed roots immediately. Failure to do so will leave crushed and torn roots. This leads to decay and inhibits growth of new roots. 2. Pile soil on the side of the trench opposite the tree. If this is not possible, place the soil on a plastic tarp, plywood or a thick bed of mulch. 3. Do not compact the backfill on the trench more than its original firmness. 4. Water the backfill to allow the roots to begin healing. Trenching near a tree can kill as much as 40%-50% of the tree’s roots. If the tree you are working around is in a confined space and your equipment will be coming close, it is important for you to protect the trunk. Wrap the tree trunk in old tires or place 2” x 4” studs around the tree and rope or band them together. ROOT PRUNING DETAIL PLEASE KEEP THIS SHEET FOR REFERENCE 2” x 4” or 2” x 2” Dimensional Lumber Sturdy Strap (steel, nylon, or synthetic rope) 2” x 4” ’or 2” x 2” - 6 to 8 Feet Tall Dimensional Lumber Spaced 3” Apart Sturdy Strap (steel, nylon, or synthetic rope) Bridge With 4” - 6” Deep Course Woody Debris or 4” x 4” Dimensional Lumber and 3/4” Plywood or Steel Road Plate. Note: See Local Ordinance Requirements and Arborist’s Report for Additional Protection Specifications and Guidelines. Trunk Protection Vertical Timber Detail 6’ MIN.Page 114 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 D3: Section 29.10.1005. - Protection of Trees During Construction Tree Protection Zones and Fence Specifications 1.Size and materials: Six (6) foot high chain link fencing, mounted on two-inch diameter galvanized iron posts, shall be driven into the ground to a depth of at least two (2) feet at no more than ten-foot spacing. For paving area that will not be demolished and when stipulated in a tree preservation plan, posts may be supported by a concrete base. 2.Area type to be fenced: Type I: Enclosure with chain link fencing of either the entire dripline area or at the tree protection zone (TPZ), when specified by a certified or consulting arborist. Type II: Enclosure for street trees located in a planter strip: chain link fence around the entire planter strip to the outer branches. Type III: Protection for a tree located in a small planter cutout only (such as downtown): orange plastic fencing shall be wrapped around the trunk from the ground to the first branch with two-inch wooden boards bound securely on the outside. Caution shall be used to avoid damaging any bark or branches. 3.Duration of Type I, II, III fencing: Fencing shall be erected before demolition, grading or construction permits are issued and remain in place until the work is completed. Contractor shall first obtain the approval of the project arborist on record prior to removing a tree protection fence. 4.Warning Sign: Each tree fence shall have prominently displayed an eight and one-half-inch by eleven-inch sign stating: "Warning —Tree Protection Zone—This fence shall not be removed and is subject to penalty according to Town Code 29.10.1025.” Text on the signs should be in both English and Spanish (Appendix E). Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 20 26 Page 115 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 All persons, shall comply with the following precautions 1.Prior to the commencement of construction, install the fence at the dripline, or tree protection zone (TPZ) when specified in an approved arborist report, around any tree and/or vegetation to be retained which could be affected by the construction and prohibit any storage of construction materials or other materials, equipment cleaning, or parking of vehicles within the TPZ. The dripline shall not be altered in any way so as to increase the encroachment of the construction. 2.Prohibit all construction activities within the TPZ, including but not limited to: excavation, grading, drainage and leveling within the dripline of the tree unless approved by the Director. 3.Prohibit disposal or depositing of oil, gasoline, chemicals or other harmful materials within the dripline of or in drainage channels, swales or areas that may lead to the dripline of a protected tree. 4.Prohibit the attachment of wires, signs or ropes to any protected tree. 5.Design utility services and irrigation lines to be located outside of the dripline when feasible. 6.Retain the services of a certified or consulting arborist who shall serve as the project arborist for periodic monitoring of the project site and the health of those trees to be preserved. The project arborist shall be present whenever activities occur which may pose a potential threat to the health of the trees to be preserved and shall document all site visits. 7.The Director and project arborist shall be notified of any damage that occurs to a protected tree during construction so that proper treatment may be administered. Prohibited Activities The following are prohibited activities within the TPZ: •Grade changes (e.g. soil cuts, fills); •Trenches; •Root cuts; •Pedestrian and equipment traffic that could compact the soil or physically damage roots; •Parking vehicles or equipment; •Burning of brush and woody debris; •Storing soil, construction materials, petroleum products, water, or building refuse; and, •Disposing of wash water, fuel or other potentially damaging liquids. Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 21 26 Page 116 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Monitoring Any trenching, construction or demolition that is expected to damage or encounter tree roots should be monitored by the project arborist or a qualified ISA Certified Arborist and should be documented. The site should be evaluated by the project arborist or a qualified ISA Certified Arborist after construction is complete, and any necessary remedial work that needs to be performed should be noted. Root Pruning Roots greater than two inches in diameter shall not be cut. When roots over two inches in diameter are encountered and are authorized to be cut or removed, they should be pruned by hand with loppers, handsaw, reciprocating saw, or chain saw rather than left crushed or torn. Roots should be cut beyond sinker roots or outside root branch junctions and be supervised by the project arborist. When completed, exposed roots should be kept moist with burlap or backfilled within one hour. Boring or Tunneling Boring machines should be set up outside the drip line or established Tree Protection Zone. Boring may also be performed by digging a trench on both sides of the tree until roots one inch in diameter are encountered and then hand dug or excavated with an Air Spade® or similar air or water excavation tool. Bore holes should be adjacent to the trunk and never go directly under the main stem to avoid oblique (heart) roots. Bore holes should be a minimum of three feet deep. Tree Pruning and Removal Operations All tree pruning or removals should be performed by a qualified arborist with a C-61/D-49 California Contractors License. Treatment, including pruning, shall be specified in writing according to the most recent ANSI A-300A Standards and Limitations and performed according to ISA Best Management Practices while adhering to ANSI Z133.1 safety standards. Trees that need to be removed or pruned should be identified in the pre-construction walk through. Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 22 26 Page 117 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Appendix E: Tree Protection Signs E1: English Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 23 26 Warning Tree Protection Zone This Fence Shall Not Be Removed And Is Subject To Penalty According To Town Code 29.10.1025 Page 118 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 E2: Spanish Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 24 26 Cuidado Zona De Arbol Pretejido Esta valla no podrán ser sacados Y está sujeta a sanción en función de Código Ciudad del 29.101025 Page 119 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Qualifications, Assumptions, and Limiting Conditions Any legal description provided to the consultant is assumed to be correct. Any titles or ownership of properties are assumed to be good and marketable. All property is appraised or evaluated as though free and clear, under responsible ownership and competent management. All property is presumed to be in conformance with applicable codes, ordinances, statutes, or other regulations. Care has been taken to obtain information from reliable sources. However, the consultant cannot be responsible for the accuracy of information provided by others. The consultant shall not be required to give testimony or attend meetings, hearings, conferences, mediations, arbitration, or trials by reason of this report unless subsequent contractual arrangements are made, including payment of an additional fee for such services. This report and any appraisal value expressed herein represent the opinion of the consultant, and the consultant’s fee is not contingent upon the reporting of a specified appraisal value, a stipulated result, or the occurrence of a subsequent event. Sketches, drawings, and photographs in this report are intended for use as visual aids, are not necessarily to scale, and should not be construed as engineering or architectural reports or surveys. The reproduction of information generated by architects, engineers, or other consultants on any sketches, drawings, or photographs is only for coordination and ease of reference. Inclusion of said information with any drawings or other documents does not constitute a representation as to the sufficiency or accuracy of said information. Unless otherwise expressed: a) this report covers only examined items and their condition at the time of inspection; and b) the inspection is limited to visual examination of accessible items without dissection, excavation, probing, or coring. There is no warranty or guarantee, expressed or implied, that structural problems or deficiencies of plants or property may not arise in the future. Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 25 26 Page 120 16511 Cypress Way Tree Inventory, Assessment and Protection Report November 6, 2024 Certification of Performance I Richard Gessner, Certify: That I have personally inspected the tree(s) and/or the property referred to in this report, and have stated my findings accurately. The extent of the evaluation and/or appraisal is stated in the attached report and Terms of Assignment; That I have no current or prospective interest in the vegetation or the property that is the subject of this report, and I have no personal interest or bias with respect to the parties involved; That the analysis, opinions and conclusions stated herein are my own; That my analysis, opinions, and conclusions were developed and this report has been prepared according to commonly accepted Arboricultural practices; That no one provided significant professional assistance to the consultant, except as indicated within the report. That my compensation is not contingent upon the reporting of a predetermined conclusion that favors the cause of the client or any other party, nor upon the results of the assessment, the attainment of stipulated results, or the occurrence of any other subsequent events; I further certify that I am a Registered Consulting Arborist® with the American Society of Consulting Arborists, and that I acknowledge, accept and adhere to the ASCA Standards of Professional Practice. I am an International Society of Arboriculture Board Certified Master Arborist®. I have been involved with the practice of Arboriculture and the care and study of trees since 1998. Richard J. Gessner ASCA Registered Consulting Arborist® #496 ISA Board Certified Master Arborist® WE-4341B Copyright © Copyright 2024, Monarch Consulting Arborists LLC. Other than specific exception granted for copies made by the client for the express uses stated in this report, no parts of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, recording, or otherwise without the express, written permission of the author. Monarch Consulting Arborists LLC - P.O Box 1010, Felton, CA 95018 831.331.8982 - rick@monarcharborist.com Page of 26 26 Page 121 This Page Intentionally Left Blank Page 122 Page 123 Public Noticing Map Page 124 A0 COVER SHEET REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway ReplacementC Y P R E S S W A Y GENERAL NOTES S-24-045 MARCH 28, 2025 KOLANDER RESIDENCE DRAWING INDEX LOCATION SITE MAP VICINITY AERIAL VIEWBUILDING DATA SCOPE OF WORK BUILDING CODES ARCHITECTURE & SITE DEVELOPMENT PERMIT GARAGE & BREEZEWAY 16511 CYPRESS WAY | LOS GATOS, CALIFORNIA 95030 REPLACEMENT EXHIBIT 9Page 125 A0.1 CONDITIONS OF APPROVAL REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway ReplacementPage 126 A0.2 SCCFD AMMR REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway ReplacementCOMMENTS DURING PLANNING “…”“” Page 127 A0.3 CONSTRUCTION BEST MANAGEMENT PRACTICES (BMPs) REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway ReplacementPage 128 A0.4 CALGREEN MANDATORY MEASURES REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway ReplacementGENERAL NOTES CALGREEN RESIDENTIAL BUILDING CODE MANDATORY MEASURES 4.1 PLANNING AND DESIGN CALGREEN RESIDENTIAL BUILDING CODE MANDATORY MEASURES 4.2 ENERGY EFFICIENCY 4.3 WATER EFFICIENCY AND CONSERVATION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY SECTION DESCRIPTION REQUIREMENTS SUMMARY COMPLIANCE YES NO N/A REMARKS SECTION DESCRIPTION REQUIREMENTS SUMMARY COMPLIANCE YES NO N/A REMARKS SECTION DESCRIPTION REQUIREMENTS SUMMARY COMPLIANCE YES NO N/A REMARKS SECTION DESCRIPTION REQUIREMENTS SUMMARY COMPLIANCE YES NO N/A REMARKS 4.5 ENVIRONMENTAL QUALITY ’ SECTION DESCRIPTION REQUIREMENTS SUMMARY COMPLIANCE YES NO N/A REMARKS Page 129 T-1 TREE PROTECTION PLAN REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway Replacement1 T-1 PARTIAL SITE PLAN TREE REMOVAL AND PROTECTION REQ'TS C Y P R E S S W A Y WARNING TREE PROTECTION ZONE CUIDADO ZONE DE ARBOL PRETEJIDO TREE PROTECTION SIGNAGE DETAILS Page 130 A1.0 SITE PLAN EXISTING CONDITIONS & DEMOLITION REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway Replacement1 A1.1 SITE PLAN GENERAL NOTES APN: 532-24-004 C Y P R E S S W A Y WASTE MANAGEMENT TREE REMOVAL AND PROTECTION REQ'TS WARNING TREEPROTECTIONZONE TREE PROTECTION DETAIL CUIDADO ZONE DEARBOLPRETEJIDO REFER TO T-1 TREE PROTECTION PLAN FOR FURTHER INFORMATION AND DETAILS Page 131 A1.1 SITE PLAN REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway Replacement1 A1.1 SITE PLAN GENERAL NOTES APN: 532-24-004 C Y P R E S S W A Y MISC. NOTES SITE/BUILDING DATA GARAGE Page 132 A1.2 SITE PLAN REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway Replacement1 A1.2 SITE PLAN WATER QUALITY NOTES C Y P R E S S W A Y CONSTRUCTION SITE FIRE SAFETY NOTES ZONE 0 ZONE 1 ZONE 2 DEFENSIBLE SPACE/FIRE BREAK NOTES GARAGE Page 133 A2.1 FLOOR PLANS REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway Replacement2 A2.1 FLOOR PLAN - PROPOSED GENERAL NOTES LEGEND 1 A2.1 FLOOR PLAN - DEMOLITION SHEET NOTES WALL LEGEND FINISH NOTES Page 134 A2.2 ROOF PLAN & SITE ELEMENTS REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway Replacement1 A2.2 ROOF PLAN - PROPOSED GENERAL NOTES SHEET NOTES WILDLAND URBAN INTERFACE COMPLIANCE Page 135 A3.0 EXISTING EXTERIOR ELEVATIONS REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway ReplacementC A3.0 REAR EXTERIOR ELEVATION (SOUTH) A A3.0 FRONT EXTERIOR ELEVATION (NORTH) D A3.0 SIDE EXTERIOR ELEVATION (WEST) B A3.0 SIDE EXTERIOR ELEVATION (EAST) EXTERIOR COLOR SCHEME Page 136 A3.1 EXTERIOR ELEVATIONS REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway ReplacementC A3.1 REAR EXTERIOR ELEVATION (SOUTH) A A3.1 FRONT EXTERIOR ELEVATION (NORTH) D A3.1 SIDE EXTERIOR ELEVATION (WEST) B A3.1 SIDE EXTERIOR ELEVATION (EAST) EXTERIOR COLOR SCHEMEEXTERIOR COLOR SCHEME Page 137 A3.2 BUILDING SECTIONS REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway ReplacementE A3.2 BUILDING SECTION C A3.2 BUILDING SECTION WITH DORMERS A A3.2 BUILDING SECTION D A3.2 BUILDING SECTION B A3.2 BUILDING SECTION Page 138 A3.3 OVERALL SITE SECTION REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway ReplacementA A3.3 OVERALL SITE SECTION Page 139 A3.4 OVERALL SITE SECTION REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway ReplacementB A3.4 OVERALL SITE SECTION Page 140 A7.1 DOOR & WINDOW SCHEDULES AND DETAILS DOOR TYPES FRAME TYPES 1 A7.1 DOOR HEAD DETAIL REVISIONS CONDITIONS & RESTRICTIONS SHEET TITLE 3360 De La Cruz BoulevardSanta Clara, CA 95054www.ba-builders.commain office: (408) 648-4500fax: (408) 588-0095CA license: B-443949BAY AREABUILDERSINCORPORATEDPROJECT TITLE KOLANDERRESIDENCE16511 Cypress Way | Los Gatos, California 95030Garage & Breezeway ReplacementHARDWARE GROUPS: 2 A7.1 DOOR JAMB DETAIL WINDOW TYPES: 5 A7.1 WINDOW HEAD DETAIL 6 A7.1 WINDOW JAMB DETAIL 7 A7.1 WINDOW SILL DETAIL WINDOW NOTES: WINDOW SCHEDULE DOOR SCHEDULE DOOR NOTES: 3 A7.1 PENETRATION DETAIL AT WALL 4 A7.1 ELECTRICAL OUTLET/J-BOX8 A7.1 BOLLARD DETAIL Page 141 1 INCH = 10 FEET16511 CYPRESS WAY FOR TOWN OF LOS GATOSAPN: 532-24-004 SCOTT & JACKEY KOLANDER GARAGE ADDITION & BREEZEWAY REPLACEMENT 24-033-1FEBRUARY 2025CIVIL3.dwgPLANNING SUBMITTALGRADING & DRAINAGE PLAN 303 Potrero St., Suite 42-202, Santa Cruz, CA 95060 831-425-3901 www.riengineering.com , c.dwg namedateproject no.scaleAS SHOWNPage 142 16511 CYPRESS WAY FOR TOWN OF LOS GATOSAPN: 532-24-004 SCOTT & JACKEY KOLANDER GARAGE ADDITION & BREEZEWAY REPLACEMENT 24-033-1FEBRUARY 2025CIVIL3.dwgPLANNING SUBMITTALDETAILS 303 Potrero St., Suite 42-202, Santa Cruz, CA 95060 831-425-3901 www.riengineering.com , c.dwg namedateproject no.scaleAS SHOWNPage 143 1 INCH = 10 FEET16511 CYPRESS WAY FOR TOWN OF LOS GATOSAPN: 532-24-004 SCOTT & JACKEY KOLANDER GARAGE ADDITION & BREEZEWAY REPLACEMENT 24-033-1FEBRUARY 2025CIVIL3.dwgPLANNING SUBMITTALSTORMWATER POLLUTIONCONTROL PLAN 303 Potrero St., Suite 42-202, Santa Cruz, CA 95060 831-425-3901 www.riengineering.com , c.dwg namedateproject no.scaleAS SHOWNPage 144