Exhibit 11 - Development PlansSHEETOFSHEET TITLECOPYRIGHT:
PROJECT NO:CAD DWG FILE:DRAWN BY:CHK'D BY:DESCRIPTIONDATEMARKOWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com408.843.8067 c2023JER DESIGN GROUPY:\Shared\Project's\15411National Ave. LosGatos\DWG'S\240610 - Rev.Ramya Resi.rvtPLANNING 20109242VYANKATESH B. & RAMYAMUDDADA RES.424-12-140AuthorChecker15411 NATIONAL AVE. LOS GATOS, CA.-CS COVER SHEET424-12-140APN MAPVICINITY MAPNORTHCONTACTS
APPLICABLE CODE
SHEET INDEX
SCOPE OF WORK2022 CBCCALIFORNIA BUILDING CODE2022 CRCCALIFORNIA RESIDENTIAL CODE2022 CECCALIFORNIA ELECTRICAL CODE2022 CPCCALIFORNIA PLUMBING CODE2022 CMCCALIFORNIA MECHANICAL CODE2022 CEnCCALIFORNIA ENERGY CODE2022 CALGCALIFORNIA GREEN BUILDING STANDARD CODE2022 ASCEMINIMUM DESIGN LOADS FOR BUILDING
2022 SDPWS SPACEIAL DESIGN PROVISIONS FOR WIND & SEISMIC2019 CFC CALIFORNIA FIRE CODEOWNER RESIDENCE VYANKATESH B. & RAMYA MUDDADA15415 NATIONAL AVE. LOS GATOS, CA. 95032c408.382.1170e ramyamuddada@yahoo.comPROJECT SITEPROJECT SITEARCHITECTURE-CS COVER SHEETA0.1 GENERAL NOTESDESIGNERJER DESIGN GROUP15919 VILLAGE WAY MORGAN HILL, CA. 95037JOSE RAMAc 408-843-8067e jer@jerdesigngroup.comCIVIL ENG.V&H ENG.DAVE VORRHIES, PE c 408.472.5222e dave@vandheng.comPROJECT INFORMATIONNORTHAPN#:424 12 140ADDRESS:15411 NATIONAL AVE. LOS GATOS, CA.ZONINGR-1:8MAX. ALLOWABLEFLOOD ZONE DLOT COVERAGE 40%5,283 SF. (LOT SIZE 13,209 SF.)FAR(.35 -(10.7 -5)/25 x .20) = .3044 (3,26 SF. FAR)OCCUPANCY GROUP: R3 AND UFIRE SPRINKLER:YESTYPES OF CONSTRUCTION:VB DEFERRED SUBMITTALFIRE SPRINKLER SYSTEMNEW SINGLE-FAMILY
15411 NATIONAL AVE..
LOS GATOS, CA 95032
APN:424-12-140
MUDDADA RESIDENCE
NORTHT-24NRG SOLUTIONS,LLCSTRUCTURE GPM Eng.3340 WALNUT AVE. II STE. 292FREMONT, CA. 94538MOHAMED S. GENIDY, PE.m: 510.377.7866 o: 650.331.7264e: mgenidy@gpmengineers.comARCHITECTURE & SITE APPLICATION ONLYPV SYSTEM “A separate building permit is required for the PV system that is required by the California Energy Code Performance or Prescriptive standards. The separate PV System permit must be finaled prior to issuance of Certificate of Occupancy”.NOTE:: THIS RESIDENCE WILL COMPLY WITH TOWN'S ALL ELECTRIC APPLIANCE, ELECTRIC
VEHICLE AND ENERGY STORAGE SYSTEM REQUIREMENTS IN ACCORDANCE WITH TOWN CODE.22A0.3A ARIEL VIEWPOINTSA0.6 3D VIEWSA0.7 SHADOW STUDYA0.8 SITE PLAN DIARGAMA0.9 DIAGRAM BUILDING STRUCTURE'S ADJACENTA0.10 STREETSCAPEA0.11 EXISTING SITE & DEMOA0.12 CONCEPTURAL LANDSCAPEA0.13 EROSION CONTROLARCHITECTUREA1.0 SITE PLANA1.1 FIRST Lvl - FLOOR PLANA1.2 SECOND Lvl - FLOOR PLANA1.3 BASEMENT LvlA1.4 MAIN STRUCT - ROOF PLANA2.1 BUILDING SECTIONSA3.1 SITE SECTIONA4.0 PROPOSED BUILDING ELEVATIONSA4.1 PROPOSED BUILDING ELEVATIONSA4.3 COURTYURD ELEVATIONS / MAT.A8.0 DETAILS - SITEA8.2 WINDOW DETAILS1309/03/2024
EXISTING PROPOSED MAXIMUM ALLOWABLE
GP LAND USE DESIGNATION Low Density Res.SAME Same
Zoning R-1:8 SAME Same
Gross Lot Size 13,209 SAME Same
Net Lot size 10,729 SAME Same
Average Slope 10% less SAME Same
Use Flag Lot W/ Accessory Struct.Single Family
Residence
Floor Area
Attic Non-Habitable00
2nd. Floor 01,518
1st. Floor0 1,722
Total Countable FAR - Sub N/A 3,240 3263 Max. Allowable FAR
Garage Attached0 901 901 SF. Max.
Coverage Porche Front 36
Covered Porche Rear0 570
Total - Sub 1,507
Total 4,747
Below Grade 1200 Exempt
Below Grade JADU, SEPARATE
PERMIT, NOT PART OF THIS APP.
500 Exempt Max. 500 SF. (FAR)
Detached ADU, SEPARATE
PERMIT, NOT PART OF THIS APP.
900 1,073 SF. Max. 10% FAR
Bump
Lot coverage
Porches, First Floor, & Garage 3,229 5,284
24%40%
Struct. Height
Main Structure Height N/A 30 SF.30 SF.
Main Struct. Setback
Front 25'25'
Side 8'8'
Rear 20'20'
Tree Removal #61,62, 2 additional
trees at rear = Total 4
Tree Removal Permit
Tree Replacement 2,3,3 = Total 8 Per Tree Removal Permit
15411 NATIONAL AVENUE - NEW SINGLE - FAMILY RESIDENCE APN: 424-12-140LO
T SIZE AND DRIVEWAY: FEET DESIGNATED FOR THE PROPOSED DRIVEWAY TO ACCOMMODATE ENTRANCES FOR BOTH PROPERTIES. LOT IS APPROXIMATELY 13,209 SQUARE FEET, WITH 2,480 SQUARE VACANTMAIN STRUCTURE: THE MAIN STRUCTURE WILL BE A TWO-FLOOR SINGLE-FAMILY RESIDENCE. THE FIRST FLOOR WILL HAVE 1, SQUARE FEET OF LIVING SPACE AND A GARAGE TOTALING 901
SQUARE FEET. THE SECOND FLOOR WILL HAVE THREE BEDROOMS AND THREE FULL BATHROOMS, INCLUDING A MASTER BEDROOM SUITE BASEMENT AND JADU: THE MAIN STRUCTURE WILL HAVE A BASEMENT BELOW GRADE AND AN
ATTACHED JUNIOR ACCESSORY DWELLING UNIT (JADU) OF 500 SQUARE FEET NOT PART OF THIS
(RBC). THE BASEMENT WILL ALSO INCLUDE A CELLAR OF 1, SQUARE FEET FOR WINE, DRY
FOOD, AND GENERAL STORAGE. DETACHED ADU: UNDER A SEPARATE PERMIT NOT INCLUDED IN THIS SUBMITTAL, A DETACHED ACCESSORY DWELLING UNIT (ADU) WILL BE PROPOSED. THE ADU WILL MEET THETREE PRESERVATION AND REPLACEMENT: SIX TREES IDENTIFIED IN THE ARBORIST REPORT WILL BE REPLACED, AND THE OWNER WILL FOLLOW REPLACEMENT REQUIREMENTS MANDATED BY
CITY ORDINANCES.
722
APPLICATION ), WITH WINDOWS MEETING ALL REQUIREMENTS FROM THE RESIDENTIAL BUILDING CODE )
200AN
D WILL HAVE A TOTAL AREA OF 900 SQUARE FEET.OVERALL, THE SCOPE OF WORK INCLUDES FAMILY RESIDENCE WITH A BASEMENT AND JADU, PRESERVATION AND REPLACEMENT OF TREES, GRADING, CONSTRUCTION OF A SINGLE-(UNDER SEPERATE PERMIT)
THE PROJECT MEETS' SETBACKS, LOT COVERAGE, HEIGHT, PARKING AND IS LESS THAN THE
MAXIMUM ALLOWABLE FAR AND SQUARE FOOTAGE ALLOWED BY TOWN CODE FOR A R1:8 ZONED
PARCEL.
TOWN CODE
LIVING SPACEON THE SECOND FLOOR WILL BE 1, SQUARE FEET. THE TOTAL FLOOR AREA 518
RATIO (FAR) WILL BE 3, SQUARE FEET,240
EXHIBIT 11
NORTH ARROW
INDICATES REFERENCE NORTH
BUILDING SECTIONS
SECTION IDENTIFICATION
SECTION CUT
IS SHOWN
DETAIL REFERENCE
ELEVATION
(NUMBERS)
(LETTERS)
ELEVATION IDENTIFICATION
SECTION IDENTIFICATION
SHEET WHERE SECTION
DETAIL REFERENCE
KEY NOTE
INTERIOR ELEVATION
DETAIL IDENTIFICATION
SHEET WHERE DETAIL IS SHOWN
SHEET WHERE DETAIL IS SHOWN
DETAIL IDENTIFICATION
DOOR MARK
DOOR OPENING
WINDOW OPENING
DIMENSION TO CENTER
OPENING INDICATIONS
CORRESPONDING NUMBER
DIMENSION TO ROUGH FACE
(LETTERS)
REVISION
CONTROL POINT OR
WORK POINT,
CLOUD AROUND REVISION
DATUM POINT
DIMENSION ABOVE FLOOR
REFERENCE ELEVATION+10'-0"
ROOF ACCESS HATCH
GUTTER AND DOWNSPOUT
FOR MTL. AWNING ON FRONT
FACADE ONLY. PAINT DS TO
MATCH EXTERIOR WALL
WALL TYPE##
14. NO WORK DEFECTIVE IN CONSTRUCTION OR QUALITY OR DEFICIENT IN
ANY REQUIREMENTS OF DRAWINGS AND SPECIFICATIONS WILL BE
ACCEPTABLE IN CONSEQUENCE OF OWNER'S OR ARCHITECT'S
FAILURE TO DISCOVER OR TO POINT OUT DEFECTS OR DEFICIENCIES
DURING CONSTRUCTION; NOR WILL PRESENCE OF INSPECTORS ON
WORK RELIEVE CONTRACTOR FROM RESPONSIBILITY FOR SECURING
QUALITY AND PROGRESS OF WORK, AS REQUIRED BY CONTRACT.
DEFECTIVE WORK SHALL BE REPLACED BY WORK CONFORMING WITH
INTENT OF CONTRACT. NO PAYMENT, WHETHER PARTIAL OR FINAL,
SHALL BE CONSTRUED AS AN ACCEPTANCE OF DEFECTIVE WORK OR
IMPROPER MATERIALS. CONTRACTOR SHALL PROTECT WORK AREA
AND NEW OR EXISTING MATERIALS AND FINISHES FROM DAMAGE
WHICH MAY OCCUR FROM CONSTRUCTION, DEMOLITION, DUST, WATER,
ETC.. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO
PROPERTY OR CONSTRUCTION RESULTING FROM WORK OF
CONTRACTOR AND/ OR SUBCONTRACTORS, AND SHALL REPAIR ALL
SUCH DAMAGE TO ORIGINAL CONDITION AT NO ADDITIONAL COST.
15. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND
INSPECTIONS.
16. THE CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE
MATERIALS ON A REGULAR BASIS, AND SHALL EXERCISE STRICT
CONTROL OVER JOB CLEANING TO PREVENT ANY DIRT, DEBRIS, OR
DUST FROM AFFECTING, IN ANY WAY, FINISHED AREAS IN OR
OUTSIDE THE JOBSITE.
17. THE GENERAL CONTRACTOR SHALL MAINTAIN A CURRENT AND
COMPLETE SET OF CONSTRUCTION DOCUMENTS ON THE JOB SITE
DURING ALL PHASES OF CONSTRUCTION FOR USE OF ALL TRADES
AND SHALL PROVIDE ALL SUBCONTRACTORS WITH CURRENT
CONSTRUCTION DOCUMENTS AS REQUIRED. ONE SET OF RECORD
DRAWINGS SHALL BE PROVIDED TO THE ARCHITECT AT COMPLETION.
18. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING LOCATION
OF ALL UTILITIES PRIOR TO EXCAVATION AND/ OR DEMOLITION.
19. CONTRACTOR SHALL PROVIDE ALL CEILING OR WALL ACCESS PANELS
(OR ACCESS DOORS) AS REQUIRED BY THE AIR CONDITIONING,
PLUMBING, AND ELECTRICAL SYSTEM. PROVIDE APPROVED
ASSEMBLIES WITH SELF CLOSING DEVICES IN RATED CONSTRUCTION.
20. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED.
21. ALL DIMENSIONS NOTED "CLEAR" OR "CLR" ARE FOR MINIMUM
CLEARANCES AND MUST BE FIELD VERIFIED AND STRICTLY
MAINTAINED.
22. ALL DIMENSIONS NOTED "VERIFY" OR "VIF" ARE TO BE CHECKED BY
CONTRACTOR PRIOR TO CONSTRUCTION. ANY VARIANCES SHOULD
BE REPORTED TO THE ADESIGNER IMMEDIATELY FOR RESOLUTIONS.
23. ABBREVIATIONS USED ARE THOSE IN COMMON USE. ARCHITECT WILL
DEFINE INTENT OF ANY QUESTIONS.
24. ALL ELECTRICAL OUTLETS & CONTROLS SHALL COMPLY WITH
ARTICLES 3-210 & 3-380 OF THE STATE ELECTRICAL CODE.
JST.JOIST
VINYL COMPOSITION TILEVCT
L
L
L
YARD
WROUGHT IRON
WOOD
WITHOUT
WITH
WEIGHT
WEATHER PROOF
WAINSCOT
WINDOW
WATER CLOSET
VERTICAL
VOLT AMPERE
VERIFY IN FIELD
VAPOR BARRIER
URINAL
UNFINISHED
TYPICAL
TRANSFORMER
TOILET
THROUGH
THICK
THREADED
THRESHOLD
TELEPHONE
TELEVISION OUTLET
TUBE STEEL
TOP OF WALL
TOP OF SLAB
TOP OF MASONRY
TOP OF JOIST
TOP OF FOOTING
TOP OF CURB
TOP OF BEAM
TOP OF
TELEPHONE MOUNTING BOARD
THROUGH BOLT
TONGUE AND GROOVE
SYSTEM
SYMMETRICAL
SWITCH
SUSPENDED
STEEL
STANDARD
SOUND TRANSMISSION CLASS
SQUARE INCHES
SQUARE FEET
SPEAKER
SPECIFICATIONS
SPACE
SIMILAR
SHEATHING
SHEET
SERVICE ENTRANCE SECTION
SECTION
SCHEDULE
SELF CLOSING
STAINLESS STEEL
SKYLIGHT
SHUT OFF VALVE
SMOKE DETECTOR
SOLID CORE
REMOVE
ROOM
REVISION
RETURN
REQUIRED
REINFORCED
REFERENCE
REFRIGERATOR
RIGHT OF WAY
ROUGH OPENING
ROOF DRAIN OVERFLOW
ROOF DRAIN LEADER
RADIUS
QUANTITY
QUARRY TILE
POWER
POLYVINYLCLORIDE
PARTITION
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
PREFABRICATED
PERFORATED
PORCELAIN
PLYWOOD
PLUMBING
PLASTIC
PLATE
PLASTER
PHASE
PERPENDICULAR
POINT OF CONNECTION
PLASTIC LAMINATE
PROPERTY LINE
PRECAST CONCRETE
OPPOSITE
OPENING
OVER HEAD
OUTSIDE AIR INTAKE
OUTSIDE RADIUS
ORNAMENTAL IRON
OVER HANG
OUTSIDE DIAMETER
ON CENTER
NOMINAL
NUMBER
NAILER
NOT FOR CONSTRUCTION
NON-CORROSIVE METAL
NOT TO SCALE
NOT IN CONTRACT
MULLION
METAL
MODULAR
MISCELLANEOUS
MINIMUM
MANUFACTURER
MANUFACTURING
MEDIUM
MECHANICAL
MAXIMUM
MATERIAL
MASONRY
MARBLE
MASONRY OPENING
MALLEABLE IRON
MANHOLE
MACHINE BOLT
LAMINATED VENEER LUMBER
LIGHTING
LIGHT
LINOLEUM
LINEAR
LEAD
LAVATORY
LATERAL
LAMINATE
LINEAR FEET
LIGHT EMITTING DIODE
KNOCK OUT
KILN DRIED
KNOCK DOWN
JOINT
JUNCTION
JUNCTION BOX
INTERIOR
INSULATION
"INCLUDE, INCLUSIVE"
IMPREGNATED
INTERMEDIATE METALLIC CONDUIT
ISOLATED GROUND
IDENTIFICATION
INSIDE FACE
INSIDE DIAMETER
INTERCOM OUTLET
HYDRAULIC
HOT WATER
"HEATING, VENTILATING & AIR CONDITIONING"
HEATER
HORIZONTAL
HEIGHT
HARDWARE
HARDBOARD
HANDICAPPED
HOLLOW METAL
HOLLOW CORE
HOSE BIBB
GYPSUM BOARD
GYPSUM
GALVANIZED RIGID TUBING
GATE VALVE
GRADE MARK
GLUE LAMINATED BEAM
GLASS
GROUND FAULT INTERRUPTER
GROUND FAULT CIRCUIT INTERRUPTER
GARAGE
GALVANIZED
GAUGE
GALVANIZED IRON
FURNISH
FOOTING
FIRE PROOF
FLUORESCENT
FLOORING
FLOOR
FINISH
FIRE HOSE CABINET
FOUNDATION
FIRE DEPARTMENT CONNECTION
FIRE ALARM CONTROL PANEL
FABRICATE
FIBERGLASS
FLOOR SINK
FACE OF
FIELD NAILING
FIRE EXTINGUISHER
FLOOR DRAIN
FLOOR CLEAN OUT
FAN COIL
FIRE ALARM
EXTERIOR
EXISTING
EXHAUST
EXCAVATE
ELECTRIC DRINKING COOLER
EVAPORATIVE COOLER
ESTIMATE
EQUIPMENT
EQUAL
ELECTRICAL NON-METALLIC TUBING
ELECTRICAL METALLIC TUBING
ELECTRICAL METALLIC CONDUIT
ELEVATOR
"ELECTRIC, ELECTRICAL"
ELEVATION
EACH
EACH WAY
END NAILING
EXPANSION JOINT
EXHAUST FAN
EXPANSION ANCHOR
DOOR
DOWN
DEAD LOAD
DIMENSION
DIAGONAL
DIAMETER
DEMOLITION
DOUBLE
DISHWASHER
DOWN SPOUT
DECOMPOSED GRANITE
DRINKING FOUNTAIN
PENNY
COPPER
CONTRACTOR
CONTINUOUS
CONSTRUCTION
CONCRETE
COMBINATION
COLUMN
CENTERED
CONCRETE MASONRY UNIT
CLEAR
CLOSET
CAULKING
CEILING
CENTERLINE
CIRCUIT BREAKER
CHANNEL
CUBIC FEET PER MINUTE
CERAMIC
CEMENT
CLOSED CIRCUIT TELEVISION
CAMBER
CABINET
CERAMIC TILE
CLEAN OUT
CONTROL JOINT
CAST IN PLACE
CONSTRUCTION DOCUMENTS
CONCRETE ASBESTOS PIPE
BRONZE
BEARING
BRASS
BEAM
BLOCKING
BLOCK
BUILDING
BOARD
BACK OF CURB
BUILT UP
BOTTOM OF FOOTING
BOTTOM OF
BOUNDARY NAILING
BENCH MARK
ANGLE
AMERICAN WIRE GAUGE
AVERAGE
ASPHALT
ANNEALED
ALTERNATE
ALUMINUM
AIR HANDLER UNIT
ABOVE GRADE
ADDITION or ADDENDUM
ACOUSTICAL CEILING TILE
ACOUSTIC
ASBESTOS-CEMENT BOARD
ABOVE
ACRYLONITRILE-BUTADIENE-STYRENE
AGGREGATE BASE COURSE
AIR CONDITIONING
ABOVE FINISHED GRADE
ABOVE FINISHED FLOOR
ANCHOR BOLT
AMPERES
YD.
W.I.
WD.
W/O
W/
WT.
WP
WCT
WDW
W/C
VERT.
VA
V.I.F.
V.B.
UR
UNF.
TYP.
TRANS.
TLT.
THRU
THK.
THD.
TH.
TEL.
T.V.
T.S.
T.O.W.
T.O.S.
T.O.M.
T.O.J.
T.O.F.
T.O.C.
T.O.B.
T.O.
T.M.B.
T.B.
T & G
SYS.
SYM
SW
SUSP.
STL.
STD.
STC
SQ. IN.
SQ. FT.
SPKR.
SPECS
SPA.
SIM.
SHT'G.
SH
SES
SECT.
SCHED.
SC
S/S
S/L
S.O.V.
S.D.
S.C.
RMV.
RM
REV.
RET.
REQ'D.
REINF.
REF.
REF
R.O.W. or R/W
R.O.
R.D.O.
R.D.L.
R
QTY.
Q.T.
PWR.
PVC
PTN.
PSI
PSF
PREFAB.
PERF.
PORC.
PLYWD.
PLUMB.
PLAS.
PL. or P
PL.
PH or ∅
PERP. or
P.O.C.
P.LAM.
P.L. or P
P.C.
OPPO.
OPNG.
OH
OAI
O.R.
O.I.
O.H.
O.D.
O.C.
NOM.
NO.
NLR.
NFC
NCM
N.T.S.
N.I.C.
MUL
MTL.
MOD
MISC.
MIN.
MFR.
MFG.
MED.
MECH.
MAX.
MAT'L
MAS.
MAR.
M.O.
M.I.
M.H.
M.B.
LVL
LTG.
LT.
LINO.
LIN.
LD.
LAV
LAT.
LAM
L.FT.
L.E.D.
KO
KD
K-D
JT.
JCT
J-BOX
INT.
INSUL.
INCL.
IMPG
IMC
IG
ID
I.F.
I.D.
I.C.
HYD.
HW
HVAC
HTR
HOR.
HGT.
HDW
HDBD.
H/C
H.M.
H.C.
H.B.
GYP. BD.
GYP.
GRC
GM
GM
GLB
GL
GFI
GFCI
GAR.
GALV.
GA.
G.I.
FURN.
FTG.
FP
FLUOR.
FLG.
FL
FIN.
FHC
FDN.
FDC
FACP
FAB.
F/G
F.S.
F.O.
F.N.
F.E.
F.D.
F.C.O.
F.C.
F.A.
EXT.
EXIST. or E
EXH.
EXC
EWC
EVAP.
EST.
EQUIP.
EQ.
ENT
EMT
EMC
ELEV.
ELECT.
EL
EA.
E.W.
E.N.
E.J.
E.F.
E.A.
DR
DN.
DL
DIM.
DIAG.
DIA. or ∅
DEMO
DBL.
D/W
D.S.
D.G.
D.F.
d
CU
CONTR.
CONT.
CONST.
CONC.
COMB.
COL.
CNTRD.
CMU
CLR.
CLO.
CLKG.
CLG.
CL or C
CKT. BKR.
CH or
CFM
CER
CEM.
CCTV
CAM.
CAB
C.T.
C.O.
C.J.
C.I.P.
C.D.
C.A.P.
BRZ
BRG.
BR
BM.
BLKG.
BLK.
BLDG
BD.
B/C
B.U.
B.O.F.
B.O.
B.N.
B.M.
AWG
AVG
ASPH.
ANL
ALT.
AL. or ALUM.
AHU
AG
ADD.
ACT
ACOU.
ACB
ABV.
ABS
ABC
A/C
A.F.G.
A.F.F.
A.B.
A
COLUMN OR GRID LINE
POINT OF CIRCLE QUAD
TO COLUMN LINE.
LETTERS LEFT TO RIGHT.
NUMBERS TOP TO
BOTTOM
1.ALL WORK LISTED, SHOWN, OR IMPLIED ON THESE CONSTRUCTION
DOCUMENTS SHALL BE SUPPLIED AND INSTALLED BY THE GENERAL
CONTRACTOR EXCEPT WHERE NOTED OTHERWISE. CONTRACTOR
SHALL BE SOLELY RESPONSIBLE FOR EXECUTION OF WORK IN
ACCORDANCE WITH CONSTRUCTION DOCUMENTS. IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE
SUBCONTRACTORS'S WORK. THE CONTRACTOR SHALL CLOSELY
COORDINATE WORK WITH THAT OF SUBCONTRACTORS TO ASSURE
THAT ALL SCHEDULES ARE MET AND THAT ALL WORK IS DONE IN
CONFORMANCE WITH PLANS & SPECS.xxxx
2.ALL MATERIALS, LABOR, INSTALLATION, FABRICATIONS, ETC. SHALL
CONFORM TO ALL APPLICABLE CODES & REGULATIONS INCLUDING
BUT NOT LIMITED TO THOSE LISTED UNDER PROJECT DATA IN
THESE DRAWINGS, AND ALL LOCAL CODES. CONTRACTOR SHALL
ADHERE TO ALL RULES GOVERNING CONSTRUCTION, SAFETY,
BUILDING ACCESS AND THE USE OF THE FACILITIES AS SET BY
LOCAL & STATE AUTHORITIES AND THE LANDLORD.
3.ALL CONSTRUCTION SHALL COMPLY WITH ENERGY STANDARDS IN
TITLE 24 OF THE CALIFORNIA STATE BUILDING CODE AS OUTLINED
IN THE ENERGY CERTIFICATES PROVIDED BY THE ENERGY
CONSULTANT.
4.ALL MECHANICAL, ELECTRICAL, LIGHTING, PLUMBING, FIRE-
PROTECTION ENGINEERING TO BE "DESIGN BUILD" BY OTHERS.
OTHERS RESPONSIBLE FOR ENGINEERING, PERMITS, FEES,
CALCULATIONS, REPORTS, DRAWINGS, ETC. REQUIRED BY LOCAL
AND ALL OTHER GOVERNING AGENCIES. SUCH DESIGN SHALL BE
FULLY COORDINATED WITH ALL INFORMATION PROVIDED IN THIS
DRAWINGSET.
5.ALL "DESIGN-BUILD" SUBCONTRACTORS SHALL OBTAIN PERMITS
AND PAY PERMIT FEES FOR THEIR RESPECTIVE FIELDS OF WORK.
6.EXAMINATIONS OF THE SITE AND PORTIONS THEREOF WHICH WILL
AFFECT THIS WORK SHALL BE MADE BY THE GENERAL
CONTRACTOR AND SUBCONTRACTORS, WHO SHALL COMPARE IT
WITH THE DRAWINGS AND SATISFY THEMSELVES AS TO CONDITIONS
UNDER WHICH WORK IS TO BE PERFORMED. THEY SHALL,
ASCERTAIN AND
7.CHECK LOCATIONS OF THE EXISTING STRUCTURES AND EQUIPMENT,
AND ALL CONDITIONS DURING CONSTRUCTION WHICH MAY AFFECT
THEIR WORK. ANY CONFLICTS OR OMISSIONS, ETC. SHALL BE
REPORTED TO THE DESIGNER BEFORE BIDDING OR PROCEEDING
WITH ANY WORK.
8.ALL CONSTRUCTION DOCUMENTS ARE COMPLIMENTARY, AND WHAT
IS CALLED FOR BY ONE WILL BE AS IF CALLED FOR BY ALL. ANY
WORK SHOWN OR REFERRED TO ON ANY CONSTRUCTION DOCUMENT
SHALL BE PROVIDED AS THOUGH ON ALL RELATED DOCUMENTS.
9.DRAWINGS SHALL NOT BE SCALED. ALL DIMENSIONS ON DRAWINGS
TAKE PRECEDENCE OVER SCALE. DETAILS SHALL TAKE
PRECEDENCE OVER GENERAL FLOOR PLANS.
10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEETING THE
PROJECT SCHEDULE. PRIOR TO START OF PROJECT, THE GENERAL
CONTRACTOR SHALL VERIFY LEAD TIMES OF FINISH MATERIALS AND
SPECIAL ITEMS TO ASSURE AVAILABILITY AS SCHEDULE REQUIRES.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
MONITORING THE PROGRESS OF THE WORK AND INFORMING THE
DESIGNER AND TENANTS IMMEDIATELY OF ANY POTENTIAL DELAYS.
11.CERTAIN MATERIALS ARE SPECIFIED BY THEIR BRAND NAMES TO
ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE. ALL
REQUESTS FOR SUBSTITUTIONS OF ITEMS SPECIFIED SHALL BE
SUBMITTED TO THE ARCHITECT IN WRITING AT LEAST TWO WEEKS
PRIOR TO ORDERING OR INSTALLATION. REQUESTS WILL BE
CONSIDERED ONLY IF A BETTER PRODUCT, A MORE ADVANTAGEOUS
DELIVERY DATE OR A LOWER PRICE WITH CREDIT TO THE TENANT
WILL BE PROVIDED WITHOUT SACRIFICING QUALITY, APPEARANCE
AND FUNCTION. UNDER NO CIRCUMSTANCES WILL THE ARCHITECT
BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR
SUBSTITUTION IS NOT EQUAL QUALITY TO THE PRODUCT SPECIFIED.
SUBSTITUTE MATERIALS SHALL NOT BE PURCHASED OR INSTALLED
WITHOUT THE DESIGNER'S WRITTEN APPROVAL.
12.THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AS REQUESTED
FOR FABRICATION ITEMS, CUT SHEETS OF ALL FIXTURES AND
EQUIPMENT, AND SAMPLES OF ALL FINISHES TO DESIGNER FOR
APPROVAL PRIOR TO INSTALLATION. BY APPROVING AND
SUBMITTING SHOP DRAWINGS AND SAMPLES, CONTRACTOR
REPRESENTS THAT HE DETERMINED AND VERIFIED FIELD
MEASUREMENTS, FIELD CONSTRUCTION CRITERIA, MATERIALS,
CATALOG NUMBERS, AND SIMILAR DATA AND THAT EACH
SUBMITTAL
13.SUBMITTAL HAS BEEN CHECKED AND COORDINATED WITH
CONTRACT REQUIREMENTS. CONTRACTOR IS RESPONSIBLE FOR
ACCURACY OF SHOP DRAWINGS, PROPER FITTINGS, COORDINATION
OF WORK, CONSTRUCTION TECHNIQUES, MATERIALS, AND WORK
REQUIRED BY CONTRACT DOCUMENTS. SUBMITTALS WILL BE
REQUIRED FOR: -PAINT.
0000
6
2
A4.1
2
A4.1
A
1
A
A3.1
4
A8.2
4
A8.2
ABBREVIATIONS SYMBOLS
GENERAL NOTES
0000
NORTH
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A0.1 GENERAL NOTES424-12-14009/03/2024
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A0.3A ARIEL VIEWPOINTS424-12-140NORTH ISOMETRIC
VIEWPOINT
EAST ISOMETRIC
VIEWPOINT
WEST ISOMETRIC
VIEWPOINT
SOUTH ISOMETRIC
VIEWPOINT
RESI-ONE
STORY
RESI-ONE
STORY
RESI-TWO
STORY
RESI-TWO
STORY
RESI-TWO
STORY
RESI-ONE
STORY
RESI-ONE
STORY
RESI-ONE
STORY
RESI-ONE
STORY
RESI-ONE
STORY
COMM. TWO
STY
PROPOSED
SITE
09/03/2024
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A0.6 3D VIEWS424-12-1401 3D View 5
2 3D View 1
3 3D View 2
4 3D View 3
5 3D View 4
09/03/2024
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A0.7 SHADOW STUDY424-12-1401 SUMMER- JUNE - 9AM
4 WINTER - DECE - 9AM5WINTER - DECE - 12PM6WINTER - DECE - 3PM
2 SUMMER- JUNE -12PM
3 SUMMER- JUNE -3PM
09/03/2024
EXISTING
15415 NATIONAL AVE.
SINGLE FAMILY ONE STORY TO REMAIN
1600 SF. MAIN HOUSE
400 SF. GARAGE
TWO STORY
STRUCTURE
ADU 900 SF.
SEPERATE BUILDING
PERMIT.
PROPOERTY LINE
PROPOERTY LINE
PROPOERTY LINEPROPOERTY LINENATIONAL AVE.EXISTING TO
REMAIN
RESI-TWO STY 373
BLACKWELL DRIVE
APN 424.12.124
RESI-TWO STY 377
BLACKWELL DRIVE
APN 424.12.124
RESI-ONE STY 15385
NATIONAL AVE.
APN 424.12.127
RESI-ONE STY
15425 NATIONAL AVE.
APN 424.12.007
RESI-ONE STY
113 LEILA CT.
APN 424.12.135
RESI-ONE STY 381
BLACKWELL DRIVE
APN 424.12.126
COMMERICAL OFFICE-
TWO STY
BLACKWELL DR.
RESI-ONE STY
15439 NATIONAL AVE.
APN 424.12.137
DETACHED GARAGE RESI-TWO STY
15461 NATIONAL AVE.
APN 424.12.138
RESI-ONE STY
109 LEILA CT.
APN 424.12.134 1/A0.95/A0.92/A0.93/A0.94/A0.9
RESI-ONE STY 369
BLACKWELL DRIVE
APN 424.12.123
65' - 11"76' - 11 1/2"92' - 4"103' - 4 1/2"111' - 6"SECOND FLR.
FIRST FLR.6/A0.994' - 4 1/2"SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A0.8 SITE PLAN DIARGAM424-12-1401" = 20'-0"1 SITE PROJECT NORTH Copy 1
NORTH
09/03/2024
IMAGE 01
IMAGE 02
IMAGE 03
IMAGE 04
IMAGE 05
IMAGE 06
IMAGE 08
IMAGE 09
IMAGE 10
IMAGE 11
IMAGE 12
IMAGE 13
NATIONAL AVE.
DRIVEWAY
DRIVEWAY
#64
#61
#62
#63#64
DRIVEWAY
#63#72
DRIVEWAY
TO BE DEMO
TO BE DEMO
TO BE DEMO
#72
#68
#71
TO BE DEMO TO BE DEMO
TO BE DEMO
TO BE DEMO
TO BE DEMO
IMAGE 07
TO BE DEMO
04,0506,07,08
09,10,11
13
12
01,02,03
30' - 0"30' - 0"27' - 4"WD.FENCE7' - 0"SECOND FLR
111' - 6"
FIRST FLR
103' - 4"TREE13' - 7"EXISTING
TREE
EXISTING
TREE
NEW TREE10' - 0"10' - 0"30' - 0"12' - 11 1/2"27' - 5"26' - 10"WD.FENCE7' - 0"8' - 0"
NEW TREE
FIRST FLR
76' - 11 1/2"27' - 4 1/2"
SECOND FLR
112' - 4 1/2"
NORTH PROPERTY
381 BLACKWELL DRIVE
ONE STY 16-18' HT
NORTH PROPERTY
15385 NATIONAL AVE.
ONE STY 16-18' HT
18' - 0 1/2"18' - 0"27' - 4 1/2"27' - 2"
66' - 0"
97' - 9 1/2"WD.FENCE7' - 0"REAR OF PROPERTY
113 LEILA CT.
ONE STY 16-18' HT
PROPOSED PROPERTY FRONT OF PROPERTY
15411 NATIONAL AVE.
ONE STY 16-18' HT
NATIONAL AVE. STREET MEDICAL OFFICE BUILDING
NATIONAL AVE.
TWO STY 35'-38' HT
18' - 0"16' - 0"MAX.29' - 9"24' - 3"GARAGE 39' - 9"WD.FENCE 7-'0".NO WINDOWS2' - 0"
(N) TREES TO BE ADDED BY
OWNER FOR PRIVACY AS
NEEDED.
EXISTING TREE #72
SOUTH PROPERTY
15425 NATIONAL AVE.
ONE STY 16-18' HT
18' - 0"FRONT OF PROPERTY
369 BLACKWELL DR.
ONE STY 24' HT
12' - 0"12' - 0"8' - 2"94' - 4 1/2"24' - 0"WD FENCE7' - 0"EXISTING TREE #72
EXISTING TREE
NEIGHBORS
EXISTING TREE
NEIGHBORS
EXISTING TREE
NEIGHBORS
29' - 1"SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A0.9 DIAGRAM BUILDING STRUCTURE'S ADJACENT424-12-1401/16" = 1'-0"1 BUILDING DIAGRAM 01
1/16" = 1'-0"2 BUILDING DIAGRAM 02
1/16" = 1'-0"3 BUILDING DIAGRAM 03
1/16" = 1'-0"4 BUILDING DIAGRAM 04
1/16" = 1'-0"5 BUILDING DIAGRAM 05
1/16" = 1'-0"6 BUILDING DIAGRAM 06
09/03/2024
NORTHEAST PROPERTY
373 BLACKWELL DR.
TWO STY 28-30' HT
NORTHEAST PROPERTY
377 BLACKWELL DR.
TWO STY 28-30' HT
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A0.10 STREETSCAPE424-12-140NORTH STREET COMMERCIAL BUILDING
(NATIONAL AVE.).
NORTH STREET COMMERCIAL BUILDING
(NATIONAL AVE.).
NORTH STREET COMMERCIAL BUILDING
(NATIONAL AVE.).CONTINUECONTINUECONTINUESOUTH STREET COMMERCIAL BUILDING
(NATIONAL AVE.).
SOUTH STREET COMMERCIAL BUILDING
(NATIONAL AVE.).
09/03/2024
EXISTING PLANTER
TO BE MAINTAIN
EXISTING PLANTER
TO BE MAINTAIN
EXISTING AREA TO
BE REMOVED TO
ACCOMM. PROPOSED
DRIVEWAY
#66
#61#62
#64 #63
TO REMAIN ADJACENT
PROPERTY
#67
TO BE REMOVED
#68
#70 #69
TO REMAIN ADJACENT
PROPERTY
TO REMAIN PROVIDE TREE
PROTECTION DTL. D1
#65
TO REMAIN
#71
#72
TO REMAIN BETWEEN
PROPERTY
PROVIDE TREE
PROTECTION DTL. D1
EXISTING DRIVEWAY
TO BE REPAIR AS
NEEDED TO
ACCOMM. PROPOSED
EXISTING
STRUCTURE TO
REMAIN.
EXISTING AREA TO
BE REMOVED TO
ACCOMM. PROPOSED
DEDICATION
TO BE REMOVED GC TO REVIEW
ARBORISTS REPORT TO ACCOMM.
THE CITY ORD. REPLACMENT OF
TREES
(E) POWER LINE
OHOH
ABANDON EXISTING OVERHEAD
ELECTRICAL
EX. WM TO BE
RELOCATED
EX. FENCE TO
BE REMOVED
OH
OH
EX. WM TO
REMAIN
EX. 3 PURPLE
LEAF PLUMB
TREES TO BE
REMOVED.
TO BE
REMOVED
EX. POLE TO BE
RELOCATED
EX. ELEC.
PANEL TO
REMAIN JTJTJTEX. UNDERGROUND
ELECT.
WOOD FENCE TO REMAIN,
REPAIR AS NEEDED.
WOOD FENCE TO REMAIN,
REPAIR AS NEEDED.WOOD FENCE TO REMAIN, REPAIR AS NEEDED.WOOD FENCE TO REMAIN,
REPAIR AS NEEDED.
WOOD FENCE TO REMAIN,
REPAIR AS NEEDED.
EX. PATH TO
REMAIN.
EX. FENCE
TO REMAIN.
TREE TO BE
REMOVED
ø 1 4 ' - 0 "ø 1 0 ' - 0 "ø 8 ' - 0 "ø 1 0 ' - 0 "ø 8' - 0"9"9"
24"
15"
8"
ss
ss
ss
w
EXISTING
STRUCTURE/BUILDING/FOUNDATION
TO BE REMOVED
EXISTING CONCRETE PAVING /
SIDEWALK TO BE REMOVED
TO REMAIN BETWEEN
PROPERTY
PROVIDE TREE
PROTECTION DTL. D2
NOTE:
DEMOLITION WORK HAS BEEN COMPLETED
UNDER A SEPARATE BUILDING PERMIT.
1.THE GENERAL CONTRACTOR AND SUB-CONTRACTORS SHALL VISIT THE
SITE PRIOR TO SUBMITTING HIS PROPOSAL TO BECOME FAMILIAR WITH
ALL EXISTING FIELD CONDITIONS AND REPORT ANY DISCREPANCIES TO
THE PROJECT MANAGER
2. DEMOLITION CONTRACTOR SHALL PROVIDE ALL NECESSARY
PROTECTION MEASURES TO SAFEGUARD THE PUBLIC DURING
CONSTRUCTION ACTIVITIES.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE
LOCATION OF ALL EXISTING UNDERGROUND AND OVERHEAD
UTILITIES TO SAFEGUARD AGAINST THE INTERRUPTION OF SERVICES
TO THE PUBLIC.
4. OWNER HAS FIRST RIGHT OF REFUSAL OF ALL SALVAGEABLE
ITEMS. ALL EXISTING PERSONAL PROPERTY TO BE REMOVED BY
OTHERS PRIOR TO DEMOLITION. ALL REMAINING ITEMS ARE THE
PROPERTY OF THE OWNER. GENERAL CONTRACTOR SHALL
COORDINATE WITH OWNER THE SALVAGE OF FIXTURES,
FURNISHINGS, DOORS & MISCELLANEOUS EQUIPMENT.
5.WHILE AN ATTEMPT HAS BEEN MADE TO SHOW THE ITEMS TO BE
REMOVED, IT IS THE RESPONSIBILITY OF THE VARIOUS CONTRACTORS TO
CONDUCT ON-SITE EXAMINATIONS AND FAMILIARIZE THEMSELVES WITH
THE ACTUAL SITE CONDITIONS. ADDITIONAL ITEMS, NOT SHOWN TO BE
REMOVED, INTERFERING WITH THE COMPLETE REMOVAL OF THE
EXISTING BUILDING, SHALL BE REMOVED WITHOUT ADDITIONAL COST TO
THE OWNER.
6. CARE SHOULD BE EXERCISED IN THE REMOVAL OF WORK TO PREVENT
THE RELEASE OF TOXIC SUBSTANCES. SHOULD TOXIC SUBSTANCES,
SUCH AS ASBESTOS BE ENCOUNTERED, THE OWNER SHALL BE NOTIFIED.
UPON AUTHORIZATION, THE DISPOSAL OF SAME SHALL CONFORM TO ALL
GOVERNING CODES AND REGULATIONS. DISPOSAL SHALL BE DONE ONLY
BY CONTRACTORS LICENSED FOR THIS WORK.
7. DURING DEMOLITION AND CONSTRUCTION OPERATIONS, PROVIDE ALL
NECESSARY PROTECTION AND SAFE PASSAGE FOR THE PUBLIC. SUCH
AS BUT NOT
LIMITED TO: BARRICADES, TEMPORARY PARTITIONS, DUST BARRIERS,
SIGNS, ETC. ERECT AND MAINTAIN THESE BARRIERS TO THE
SATISFACTION OF THE OWNER AND ALL APPLICABLE RULES AND
REGULATIONS.
8. CONTRACTOR SHALL TAKE PRECAUTIONS AS TO MINIMIZE DAMAGE TO
ITEMS TO REMAIN,, INCLUDING ALL UTILITIES. DURING DEMOLITION AND
CONSTRUCTION OPERATIONS, ITEMS NOT SPECIFICALLY NOTED FOR
REMOVAL THAT ARE DAMAGED, SHALL BE REPAIRED OR REPLACED TO
MATCH EXISTING CONDITIONS AT NO ADDITIONAL COST TO THE OWNER.
9.COORDINATE CONSTRUCTION TIMING, MOVEMENT OF CONSTRUCTION
MATERIALS AND STORAGE OF REFUSE CONTAINERS WITH THE OWNER.
10.DEMOLISH ENTIRE BUILDING INCLUDING CONCRETE SLAB.
11. ELECTRICAL AND PLUMBING GENERAL CONT. TO CAP ALL LINES THAT
ARE NOT IN USE, COORD WITH OWNER.
GENERAL DEMOLITION NOTES
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A0.11 EXISTING SITE & DEMO424-12-1403/32" = 1'-0"1 SITE PROJECT EXISTING
SCOPE OF WORK
OWNER RESIDENCE
VYANKATESH B. & RAMYA
MUDDADA
15415 NATIONAL AVE.
LOS GATOS, CA. 95032
c408.382.1170
e ramyamuddada@yahoo.com
LOT SIZE AND DRIVEWAY:THE LOT IS APPROXIMATELY 10,729 SQUARE FEET
· GRADING: GRADING LEVELING BASIC ACCOMMATION NOT TO EXCEED (CUT&FILL) 50
CUBIC YARDS, FINAL GRADE UNDER A SEPATE SITE PREMIT
· PROTECTION THROUGHOUT: ENSURE THAT TREE PROTECTION MEASURES REMAIN IN
PLACE THROUGHOUT THE ENTIRE DEMOLITION AND GRADING PROCESS. THIS
INCLUDES MONITORING THE WORK SITE REGULARLY. REFER TO DETAIL SHOWN ON
SHEET A0.11
• TREE REMOVAL PERMITS PENDING AND NOT PART OF THIS APPLICATION.
DESIGNER
JER DESIGN GROUP
15919 VILLAGE WAY
MORGAN HILL, CA. 95037
JOSE RAMA
c 408-843-8067
e jer@jerdesigngroup.com
NOTE:
A SEPARATE PERMIT IS REQUIRED FOR THE OFF-SITE
IMPROVEMENTS PLAN, AND AN ADDITIONAL TREE REMOVAL
PERMIT IS ALSO REQUIRED.
09/03/2024
(E) DRIVEWAY TO REMAIN
REPAIR AS NEEDED TO
ACCOMM. PROPER
DRAINAGE SLOPE
SLOPE 1/4" MIN.
EXISTING
15415 NATIONAL AVE.
SINGLE FAMILY ONE STORY TO REMAIN
1600 SF. MAIN HOUSE
400 SF. GARAGE
TWO STORY
STRUCTURE
FF 311.57'
PAD 311.44'
ADU 900 SF.
SEPERATE BUILDING
PERMIT.
EXISTING WD FENCE @
6'-0", REPAIR AS NEEDED
2480 sf.
PROPOERTY LINE
126.22'
PROPOERTY LINE
PROPOERTY LINE85'PROPOERTY LINE85'NATIONAL AVE.EXISTING TO
REMAIN
HARDSCAPE
PAVERS
1755 SF.
HARDSCAPE
CONCRETE
DRIVEWAY
EXISTING WD FENCE @
6'-0" REPAIR AS NEEDED.
EXISTING WD
FENCE @ 6'-0"
DRAIN AREA
LANDSCAPE
126.22'
#63#64
#68
#70 #69
#71
#72
PROPOERTY LINE
124.00'
PROPOERTY LINE
124.00'
PROPOERTY LINE
124.00'PROPOERTY LINE65'#65
#66
SLOPE
2%
SLOPE
1/4%SLOPE
2%
SLOPE
2%SLOPE 2%01
01
01
04
04
04
04
04
04
06
02
05 05
02
03
03
06
SLOPE 1/4" MIN.
GRAVEL
GRAVEL ASSEMBLY
GRAVEL ASSEMBLYNEW
NEW
NEW
NEW
NEW
NEW
01
NEW NEW NEW NEW NEW
FG
310.86
311.65
310.36 309.81
309.40
309.23
311.15 310.65
FG
310.31
FG
309.73
311.80
311.21
310.73
310.50
309.02 308.68 308.35
310.55
309.27
309.27
309.06
309.40
310.44
310.55
01 01 01 01
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A0.12 CONCEPTURAL LANDSCAPE424-12-1403/32" = 1'-0"1 SITE PROJECT LANDSCAPE LANDSCAPE PLAN LEGEND
#01 -LEYLAND CYPRESS, ZONES 4–9)
TOTAL 9
#02 -CORAL BARK JAPANESE MAPLE TREE
(5-9) -24" BOX
TOTAL 2
#03 -BLUE RUG JUNIPER JUNIPERUS
HORIZONTALIS ‘WILTONII’ZONE 3-9 -24"
BOX
TOTAL 4
#04 -ORANGE NEW ZEALAND SEDGE
(CAREX TESTACEA, ZONES 6–10)
TOTAL 50
#05 -SUNDOWNER’NEW ZEALAND FLAX
(PHORMIUM ‘SUNDOWNER’, ZONES 8B–11)
TOTAL 6
#06 -ELIJAH BLUE’BLUE FESCUE (FESTUCA
GLAUCA ‘ELIJAH BLUE’, ZONES 4–9)
TOTAL 60
09/03/2024
EXISTING LANDSCAPE, REMOVE
TO ACCOMM. CONCRETE SLAB
FOR (N) DRIVEWAY AND CITY
SIDEWALK
EXISTING LANDSCAPE, STRIP TO BE REDUCE
TO ACCOMM. DRIVEWAY AND A PRIVACY
SCREEN
(E) DRIVEWAY TO REMAIN
REPAIR AS NEEDED TO
ACCOMM. PROPER
DRAINAGE SLOPE
EXISTING
15415 NATIONAL AVE.
SINGLE FAMILY ONE STORY TO REMAIN
1600 SF. MAIN HOUSE
400 SF. GARAGE
TWO STORY
STRUCTURE
FF 311.57'
PAD 311.44'
EXISTING WD FENCE @
6'-0", REPAIR AS NEEDED
2480 sf.
PROPOERTY LINE
126.22'
PROPOERTY LINE
PROPOERTY LINE85'PROPOERTY LINE85'NATIONAL AVE.EXISTING TO
REMAIN
EXISTING TO
REMAIN
HARDSCAPE
PAVERS
HARDSCAPE
CONCRETE
DRIVEWAY
EXISTING WD FENCE @
6'-0" REPAIR AS NEEDED.
EXISTING WD
FENCE @ 6'-0"
LANDSCAPE
LANDSCAPE
126.22'
#63#64
#68
#70 #69
#71
#72
PROPOERTY LINE
124.00'
PROPOERTY LINE
124.00'
PROPOERTY LINE
124.00'PROPOERTY LINE65'PROPOERTY LINE20'EX. WM TO
REMAIN
JTNEW POWER
POLE
42"
10-12"10"
10"
#65
#66
12"12"48"
E
SLOPE
2%
SLOPE
2%SLOPE
5%
SLOPE SLOPE SLOPE SE-5
ST-250ST-256
SE-5
SE-5
SE-5
NEW CLEAN-OUT
LOCATION
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A0.13 EROSION CONTROL424-12-140NORTH
3/32" = 1'-0"1 EROSION CONTROL
09/03/2024
EXISTING LANDSCAPE, REMOVE
TO ACCOMM. CONCRETE SLAB
FOR (N) DRIVEWAY AND CITY
SIDEWALK
EXISTING LANDSCAPE, STRIP TO BE REDUCE
TO ACCOMM. DRIVEWAY AND A PRIVACY
SCREEN
(E) DRIVEWAY TO REMAIN
REPAIR AS NEEDED TO
ACCOMM. PROPER
DRAINAGE SLOPE
SLOPE 1/4" MIN.
EXISTING
15415 NATIONAL AVE.
SINGLE FAMILY ONE STORY TO REMAIN
1600 SF. MAIN HOUSE
400 SF. GARAGE
SETBACK8' - 0"SETBACK8' - 0"TWO STORY
STRUCTURE
FF 311.57'
PAD 311.44'
ADU 900 SF.
SEPERATE BUILDING
PERMIT.
SETBACK
20' - 0"
25' - 0"
EXISTING WD FENCE @
6'-0", REPAIR AS NEEDED
2480 sf.
PROPOERTY LINE
126.22'
PROPOERTY LINE
PROPOERTY LINE85'PROPOERTY LINE85'NATIONAL AVE.EXISTING TO
REMAIN
EXISTING TO
REMAIN
HARDSCAPE
PAVERS
HARDSCAPE
CONCRETE
DRIVEWAY
EXISTING WD FENCE @
6'-0" REPAIR AS NEEDED.
EXISTING WD
FENCE @ 6'-0"
26' - 11"
LANDSCAPE
LANDSCAPE 8' - 3"126.22'
#63#64
#68
#70 #69
#71
#72
20' - 0"LANDSCAPE3' - 5"PROPOERTY LINE
124.00'
PROPOERTY LINE
124.00'
PROPOERTY LINE
124.00'
5' - 0"5'-0".
DEDICATION
10'-0".
ROW
20' - 0"PROPOERTY LINE65'PROPOERTY LINE20'EX. WM TO
REMAIN
JTJTJTNEW POWER
POLE
NEW LOCATION
WM
WM
WM
5' PSE
W W
W W
WWW
W
W
ssssssssss
ss
8
A8.0
8
A8.0
42"ø 35' - 0"10-12"ø 15' - 0"10"
10"ø 8' - 0"#65
#66 ø 8' - 0"ø 15' - 0"ø 15' - 0"12"12"48"
ø 4 5 ' - 0 "NEW POWER
POLE
2' - 8"
2' - 8"
03
A8.0
4
A8.0
02
A8.0
SIM.
ELEEEE
E
ss
E
ss
ss
ss
SETBACK
25'-0".
SLOPE
2%
SLOPE
2%SLOPE
5%
SLOPE SLOPE SLOPE 4
A8.0
1
A3.1
1
A3.1
2
A3.1
2
A3.1
SE-5
07
A8.0
NEW
NEW
EXISTING
2' - 8"
NEW CLEAN-OUT
LOCATION
(N) CURB,GUTTER
NEW CLEAN-OUT
LOCATION
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A1.0 SITE PLAN424-12-1403/32" = 1'-0"1 SITE PROJECT PROPOSED
NORTH
09/03/2024
FLOOR PLAN KEYNOTES
LINEN CLOSET -PROVIDE 5-20" DEEP SHELVES -DETERMINE
SPACING ON JOB WITH ARCHITECT & CLIENT.
BUILT-IN MILLWORK -SEE INTERIOR ELEVATIONS. REFER TO MILLWORK
DESIGN
UNDERMOUNT FARM SINK, KITCHEN SINK WITH
GARBAGE DISPOSAL -SELECTED BY OWNER
LAVATORY AND FAUCET -SELECTED BY OWNER
GAS RANGE COOKTOP -SEE APPLIANCE & EQUIPMENT SCHEDULE
KITCHEN ISLAND
BAR SINK -SELECTED BY OWNER, SEE DTL .
SHOWER HEAD -SELECTED BY OWNER
COUNTER TOP -SELECTED BY OWNER
TOILET-SELECTED BY OWNER
TOILET-PAPER HOLDER -SELECTED BY OWNER
PEDESTAL SINK -SELECTED BY OWNER
MIRROR -SEE INTERIOR ELEVATIONS FOR DIMENSIONS
TOWEL BAR TO BE SELECTED -PROVIDE BLKG IN WALL
REFRIGERATOR SPACE, PROVIDE RECESSED BOX FOR WATERLINE &
SHUT-OFF VALVE IN WALL FOR ICE MAKER -SEE APPLIANCE &
EQUIPMENT SPEC.
DISHWASHER -SEE APPLIANCE & EQUIPMENT SCHEDULE
SHOWER SHELF -SELECTED BY OWNER
CLOTHES WASHER -PROVIDE PLUMBING & GALVANIZED FLASHING PAN
UNDER UNIT & RECESSED VALVE AND DRAIN BOX IN WALL
SHOWER, SEE DTL. AND , SHOWER SURROUND -
SELECTED BY OWNER
PULL DOWN ATTIC ACCESS, SEE DTL.
WINE COOLER -SELECTED BY OWNER
PROVIDE HOT & COLD WATER ROUGH-IN FOR N.I.C.
WATER SOFTENER
CLOTHES ROD WITH 12" DEEP FIXED SHELF ABOVE, SEE DTL.
WALK-IN BATH TUB EQUIPPED WITH EXTENSION BOX TO FIT OPENING,
SEE DTL.
HANDRAIL -SEE DTL.
PANTRY SHELVES -PROVIDE ADJUSTABLE SHELVES
ROOF LINE ABOVE
GAS FIREPLACE -SELECTED BY OWNER
TEMPERED GLASS SHOWER SCREEN & DOOR
CRAWL SPACE VENTILATION AREAWAY -EXISTING LOCATION
PROVIDE NEW TEMPERED SHOWER GLASS DOOR WITH TOWEL BAR
CABINET SYSTEMS -N.I.C. TO BE PROVIDED & INSTALLED BY OWNER
DOWNSPOUT
BUILT-IN MICROWAVE & OVEN -SELECTED BY OWNER
UNDERCOUNTER LAZY SUSAN UNIT
TEMPER GLASS PANEL DOOR
CLOTHES DRYER -PROVIDE VENT TO EXTERIOR WITH BACKDRAFT DAMPER IN
ACCORDANCE WITH CMC 504.3.2 -SEE APPLIANCE & EQUIPMENT SCHEDULE
ADJUSTABLE SHOWER HEAD W/HANDSHOWER -SELECTED BY OWNER
BUILT-IN CABINET FOR TELEVISION
1.ALL FLOOR PLAN DIMENSIONS ARE FROM FACE OF STUD TO FACE OF
STUD, U.O.N. WHERE CLEAR DIMENSION IS INDICATED, IT SHALL BE FROM
FACE OF FINISH TO FACE OF FINISH. WHERE CENTERLINE DIMENSION IS
INDICATED, IT SHALL BE FROM CENTERLINE OF OBJECT NOTED.
2.CONTRACTOR TO PROVIDE RECESSED BOXES BEHIND ALL
REFRIGERATORS ICE-MAKERS & WATER LINE AND WASHER/DRYER.
CAULKING ALL AROUND RECESSED BOXES
3.REFER TO PROJECT INFORMATION SHEET FOR ROOF/ATTIC &
UNDERFLOOR VENTILATION CALCULATIONS.
4.PROVIDE FLOORING TRANSITION STRIP BETWEEN DISSIMILAR MATERIALS.
5.MECHANICAL & PLUMBING VENTS THROUGH EXTERIOR WALLS SHALL BE
EQUIPPED WITH WALL CAP, BUILT-IN BACKDRAFT DAMPER & BIRD
SCREEN.
WILDLAND URBAN INTERFACE FIRE HAZARD AREA
A. EXTERIOR WALL COVERING ARE CONSTRUCTED OF NON-
COMBUSTIBLE MATERIALS.
B. EXTERIOR WALL VENTS (CRAWL SPACE VENTS, COMBUSTION
AIR VENTS, ETC.)SPECIFY SUCH OPENING SHALL BE COVERED
W/CORROSION-RESISTANT NON-COMBUSTIBLE WIRE MESH WITH
MESH OPENINGS OF 1/8 INCH MAX. PER CRC R337.6.2.
6.FOR ROOM FINISHES, SEE ROOM FINISH SCHEDULE SHEET
7.SEE INTERIOR ELEVATION SHEETS FOR MOUNTING HEIGHTS
OF BATHROOM ACCESSORIES, COUNTERTOP HEIGHTS.
8.SEE SHEET A-0.1 FOR ABBREVIATIONS, LEGENDS, SYMBOLS.
9.WHERE DOOR LOCATIONS ARE NOT SPECIFIED, CENTER IN WALL OR
INSTALL 4" FROM FACE OF ADJACENT WALL FRAMING.
10. ALL INTERIOR WALLS TO BE WALL TYPE C U.O.N. -SEE WALL LEGEND.
FLOOR PLAN NOTES
11.EACH BEDROOM AND OUTSIDE SLEEPING AREA, PROVIDED WITH A SMOKE AND
CARBON MONOXIDE DETECTORS INSTALLED IN A ACCORDANCE WITH CRC. R.315
CARBON MONOXIDE ALARMS COMBINED WITH SMOKE SHALL COMPLY WITH
SECTION R315, ALL APPLICABLE STANDARD, AND REQUIREMENTS FOR LISTING
AND APPROVAL BY THE OFFICE OF THE STATE FIRE MARSHAL, FOR SMOKE ALARM.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
MILLWORK FINISH TO BE SELECTED BY OWNER -SEE INTERIOR ELEVATIONS21
22 UNDERMOUNT VANITY SINK -SELECTED BY OWNER
23
24 WALL-MOUNTED RANGE HOOD -SEE APPLIANCE & EQUIPMENT
SCHEDULE
25
26
27
28
29
30
32
31
33
34
35
36
LAUNDRY SINK -SELECTED BY OWNER
37
38
39
40
41
42
43
44
45
ROOF VENT (VENTILATION) OHAGIN 72 SQ.IN. NFVA. OR EQUAL,
SEE DTL.
46
PATIO DECK CONCRETE OR COMPOSITE ASSEMBLY BY TREX OR EQUAL.
COLOR TO BE SELECTED BY OWNER. (TO BE DETERMINED BY OWNER).
47 CONCRETE SLAB
48 PRE-FABRICATED COLUMN COVER, SEE DTL.
COLUMNS MDO WITH STONE VENEER BASE, SEE DTL.
A4.0 2
A4.1
1
3 4 5 6
B1
C1
E1
A4.1
2
A1
1
A2.1
TWO CAR
GARAGE
429 SF
GRT ROOM
77
REF.
3' - 8"4' - 0"7' - 7 1/2"5' - 4 1/2"6' - 3 1/2"12' - 4 1/2"21' - 7 1/2"
2' - 0 1/2"
6' - 9 1/2"
SINK
OVEN
/ MW
4' - 4"5' - 6"1' - 9"
12' - 8 1/2"5' - 1 1/2"9' - 10 1/2"GUEST BEDRM
W.I.C.
GRM BATHRM
HALLWAY
FOYER
HALLWAY
CLT
27 SF
POWDER
81
LIVING ROOM
2
A2.1
12' - 11"8' - 2"16' - 1"11' - 9 1/2"48' - 11 1/2"9' - 11 1/2"6' - 1 1/2"37' - 1"25' - 10 1/2"1' - 7 1/2"
1 2
80' - 8"11' - 9 1/2"16' - 1"21' - 1"48' - 11 1/2"2' - 10 1/2"7' - 1"4' - 10 1/2"1' - 3"
9' - 11 1/2"70' - 8 1/2"
80' - 8"
2' - 10 1/2"7' - 1"4' - 10 1/2"22' - 4 1/2"17' - 7"
28802480P 2680268026802680
288016080G
A4.0110' - 4"16' - 2"13' - 10"5' - 6"3' - 9"12' - 7"9' - 9"
1' - 3 1/2"
31' - 6"16' - 11 1/2"
21' - 3"3' - 6"17' - 6"5' - 10 1/2"3' - 6 1/2"6' - 0"17' - 7 1/2"4' - 2 1/2"4' - 3"12' - 5 1/2"4' - 1 1/2"21' - 4"6' - 6 1/2"4860
2424
2660
4848
84
2660 2660
5060
13' - 6"2' - 1 1/2"1' - 10 1/2"4' - 1"4' - 1"2' - 10 1/2"901 SF.
-
---
2' - 1 1/2"
3
A2.1
11' - 1"
4' - 2 1/2"6' - 10 1/2"
D/W
SINK
MINI
FRIDGE
EXH. FAN 42"
4
A2.1
GARAGE STG.
0' - 5 1/2"1' - 10"1' - 10"KITCHEN
PANTRY
A5.1
1
A5.2
4
2880 30805' - 4"3' - 0"2' - 4"2
A1.3
5' - 2"2
22' - 4"11' - 0"20' - 0"3' - 10"21' - 0"
20' - 0"20' - 0"1722 SF.
PAD 311.44'
FF 311.57'
PAD 311.44'
FF 311.57'
PAD 309.77'
FF 309.77'
MOTORCYCLE
STORAGE
SLOPE 1/4"
SLOPE 1/4"
SLOPE 1/4"
SLOPE 1/4"1' - 8"1' - 8 1/2"1' - 4"17' - 6"16' - 1 1/2"0' - 11 1/2"2 1' - 3"MILLWORK WINE HOLDER
INCL. SINK 0' - 8 1/2"SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvt
PLANNING 20109242VYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A1.1 FIRST Lvl - FLOOR PLAN424-12-1401/4" = 1'-0"1 FIRST Lvl
FIRST FLOOR: 1,722 SF.
GARAGE: 901 SF.
TOTAL: 2,623 SF.
2
09/03/2024
FLOOR PLAN KEYNOTES
LINEN CLOSET -PROVIDE 5-20" DEEP SHELVES -DETERMINE
SPACING ON JOB WITH ARCHITECT & CLIENT.
BUILT-IN MILLWORK -SEE INTERIOR ELEVATIONS. REFER TO MILLWORK
DESIGN
UNDERMOUNT FARM SINK, KITCHEN SINK WITH
GARBAGE DISPOSAL -SELECTED BY OWNER
LAVATORY AND FAUCET -SELECTED BY OWNER
GAS RANGE COOKTOP -SEE APPLIANCE & EQUIPMENT SCHEDULE
KITCHEN ISLAND
BAR SINK -SELECTED BY OWNER, SEE DTL .
SHOWER HEAD -SELECTED BY OWNER
COUNTER TOP -SELECTED BY OWNER
TOILET-SELECTED BY OWNER
TOILET-PAPER HOLDER -SELECTED BY OWNER
PEDESTAL SINK -SELECTED BY OWNER
MIRROR -SEE INTERIOR ELEVATIONS FOR DIMENSIONS
TOWEL BAR TO BE SELECTED -PROVIDE BLKG IN WALL
REFRIGERATOR SPACE, PROVIDE RECESSED BOX FOR WATERLINE &
SHUT-OFF VALVE IN WALL FOR ICE MAKER -SEE APPLIANCE &
EQUIPMENT SPEC.
DISHWASHER -SEE APPLIANCE & EQUIPMENT SCHEDULE
SHOWER SHELF -SELECTED BY OWNER
CLOTHES WASHER -PROVIDE PLUMBING & GALVANIZED FLASHING PAN
UNDER UNIT & RECESSED VALVE AND DRAIN BOX IN WALL
SHOWER, SEE DTL. AND , SHOWER SURROUND -
SELECTED BY OWNER
PULL DOWN ATTIC ACCESS, SEE DTL.
WINE COOLER -SELECTED BY OWNER
PROVIDE HOT & COLD WATER ROUGH-IN FOR N.I.C.
WATER SOFTENER
CLOTHES ROD WITH 12" DEEP FIXED SHELF ABOVE, SEE DTL.
WALK-IN BATH TUB EQUIPPED WITH EXTENSION BOX TO FIT OPENING,
SEE DTL.
HANDRAIL -SEE DTL.
PANTRY SHELVES -PROVIDE ADJUSTABLE SHELVES
ROOF LINE ABOVE
GAS FIREPLACE -SELECTED BY OWNER
TEMPERED GLASS SHOWER SCREEN & DOOR
CRAWL SPACE VENTILATION AREAWAY -EXISTING LOCATION
PROVIDE NEW TEMPERED SHOWER GLASS DOOR WITH TOWEL BAR
CABINET SYSTEMS -N.I.C. TO BE PROVIDED & INSTALLED BY OWNER
DOWNSPOUT
BUILT-IN MICROWAVE & OVEN -SELECTED BY OWNER
UNDERCOUNTER LAZY SUSAN UNIT
TEMPER GLASS PANEL DOOR
CLOTHES DRYER -PROVIDE VENT TO EXTERIOR WITH BACKDRAFT DAMPER IN
ACCORDANCE WITH CMC 504.3.2 -SEE APPLIANCE & EQUIPMENT SCHEDULE
ADJUSTABLE SHOWER HEAD W/HANDSHOWER -SELECTED BY OWNER
BUILT-IN CABINET FOR TELEVISION
1.ALL FLOOR PLAN DIMENSIONS ARE FROM FACE OF STUD TO FACE OF
STUD, U.O.N. WHERE CLEAR DIMENSION IS INDICATED, IT SHALL BE FROM
FACE OF FINISH TO FACE OF FINISH. WHERE CENTERLINE DIMENSION IS
INDICATED, IT SHALL BE FROM CENTERLINE OF OBJECT NOTED.
2.CONTRACTOR TO PROVIDE RECESSED BOXES BEHIND ALL
REFRIGERATORS ICE-MAKERS & WATER LINE AND WASHER/DRYER.
CAULKING ALL AROUND RECESSED BOXES
3.REFER TO PROJECT INFORMATION SHEET FOR ROOF/ATTIC &
UNDERFLOOR VENTILATION CALCULATIONS.
4.PROVIDE FLOORING TRANSITION STRIP BETWEEN DISSIMILAR MATERIALS.
5.MECHANICAL & PLUMBING VENTS THROUGH EXTERIOR WALLS SHALL BE
EQUIPPED WITH WALL CAP, BUILT-IN BACKDRAFT DAMPER & BIRD
SCREEN.
WILDLAND URBAN INTERFACE FIRE HAZARD AREA
A. EXTERIOR WALL COVERING ARE CONSTRUCTED OF NON-
COMBUSTIBLE MATERIALS.
B. EXTERIOR WALL VENTS (CRAWL SPACE VENTS, COMBUSTION
AIR VENTS, ETC.)SPECIFY SUCH OPENING SHALL BE COVERED
W/CORROSION-RESISTANT NON-COMBUSTIBLE WIRE MESH WITH
MESH OPENINGS OF 1/8 INCH MAX. PER CRC R337.6.2.
6.FOR ROOM FINISHES, SEE ROOM FINISH SCHEDULE SHEET
7.SEE INTERIOR ELEVATION SHEETS FOR MOUNTING HEIGHTS
OF BATHROOM ACCESSORIES, COUNTERTOP HEIGHTS.
8.SEE SHEET A-0.1 FOR ABBREVIATIONS, LEGENDS, SYMBOLS.
9.WHERE DOOR LOCATIONS ARE NOT SPECIFIED, CENTER IN WALL OR
INSTALL 4" FROM FACE OF ADJACENT WALL FRAMING.
10. ALL INTERIOR WALLS TO BE WALL TYPE C U.O.N. -SEE WALL LEGEND.
FLOOR PLAN NOTES
11.EACH BEDROOM AND OUTSIDE SLEEPING AREA, PROVIDED WITH A SMOKE AND
CARBON MONOXIDE DETECTORS INSTALLED IN A ACCORDANCE WITH CRC. R.315
CARBON MONOXIDE ALARMS COMBINED WITH SMOKE SHALL COMPLY WITH
SECTION R315, ALL APPLICABLE STANDARD, AND REQUIREMENTS FOR LISTING
AND APPROVAL BY THE OFFICE OF THE STATE FIRE MARSHAL, FOR SMOKE ALARM.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
MILLWORK FINISH TO BE SELECTED BY OWNER -SEE INTERIOR ELEVATIONS21
22 UNDERMOUNT VANITY SINK -SELECTED BY OWNER
23
24 WALL-MOUNTED RANGE HOOD -SEE APPLIANCE & EQUIPMENT
SCHEDULE
25
26
27
28
29
30
32
31
33
34
35
36
LAUNDRY SINK -SELECTED BY OWNER
37
38
39
40
41
42
43
44
45
ROOF VENT (VENTILATION) OHAGIN 72 SQ.IN. NFVA. OR EQUAL,
SEE DTL.
46
PATIO DECK CONCRETE OR COMPOSITE ASSEMBLY BY TREX OR EQUAL.
COLOR TO BE SELECTED BY OWNER. (TO BE DETERMINED BY OWNER).
47 CONCRETE SLAB
48 PRE-FABRICATED COLUMN COVER, SEE DTL.
COLUMNS MDO WITH STONE VENEER BASE, SEE DTL.
A4.0 2
A4.1
1
3 5 6
B1
C1
E1
A4.1
2
A1
1
A2.1
OPEN BELOW
STAIR
OPEN BELOW
1518 SF.
BATHRM#3BEDRM#3 BEDRM#4
CLT.#4
CLT#3
BATHRM#4
13' - 0"6' - 0"13' - 2 1/2"17' - 0"4' - 7"15' - 7"75 SF
HALLWAY
119
12' - 0"
2
A2.1
1 2
2480P2480P6080L
2880288012' - 11"8' - 2"16' - 1"11' - 9 1/2"48' - 11 1/2"9' - 11 1/2"6' - 1 1/2"1' - 7 1/2"
80' - 8"11' - 9 1/2"16' - 1"21' - 1"48' - 11 1/2"9' - 11 1/2"70' - 8 1/2"
80' - 8"
A4.01
2424
3' - 3 1/2"6' - 8"3' - 3"
EQ EQ
1' - 2"5060
2' - 9"6' - 8"
5060
EQ EQ
6' - 8"14' - 9"14' - 1 1/2"5' - 8"3' - 9"13' - 6"2' - 1 1/2"
EQ EQ
-
---1' - 10 1/2"4' - 1"4' - 1"2' - 10 1/2"27' - 10 1/2"40704070
4070
4070
4070
4070
407140714070
SOLATUBE
DETAIL
-
---
3
A2.1
14' - 4"14' - 0 1/2"3' - 6 1/2"4' - 7"7' - 9"SOLATUBE
DETAIL
6' - 10 1/2"7' - 6"
2' - 10 1/2"2' - 10 1/2"
6' - 0 1/2"4' - 3 1/2"2' - 9"
SEATING
LAUNDRY ROOM
STG.
MTR BATHRM
MTR CLT.
MASTER
BEDROOM
5060
4060
4' - 0"
SOLATUBE
DETAIL
5' - 9"
SINK SINK
SINK
TUB
SLIDING
TUB
SLIDING
4
A2.1
5' - 11"0' - 10"0' - 10"
4" / 1'-0"
4" / 1'-0"4" / 1'-0"4" / 1'-0"
A5.3
1
A5.2
10
A5.3
6
1' - 2"2880
28806080L
4060
2' - 10"2' - 10"
0' - 10"0' - 10"1' - 2"0' - 10"2' - 6"2' - 6"0' - 10"
6' - 8"
0' - 10"2' - 6"2' - 6"0' - 10"
6' - 8"
9' - 2 1/2"9' - 4 1/2"
3' - 8"
TUB TOILET3" / 1'-0"12' - 5 1/2"3" / 1'-0"3" / 1'-0"SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvt
PLANNING 20109242VYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A1.2 SECOND Lvl -FLOOR PLAN424-12-1401/4" = 1'-0"1 SECOND Lvl
SECOND FLOOR: 1,518 SF.
2
2
09/03/2024
A4.113456B1C1E1A12 A2.1124A2.1JR ADU500 SF.
CELLAR21' - 1"16' - 1"8' - 11 1/2"14' - 1"8' - 11 1/2"5' - 1"3' - 8"FACE OF SURFACE37' - 2"64' - 7"12' - 11"8' - 2"16' - 1"37' - 2"3' - 8 1/2"5' - 1 1/2"RI 12 / TR 11 13' - 5 1/2"5' - 1"1' - 5"0' - 11"0' - 11"0' - 11"0' - 11"0' - 11"0' - 11"0' - 11"0' - 11"0' - 11"0' - 11"0' - 11"0'-11".0' - 10 1/2"1200 SF.LOWER LANDINGEGRESS WINDOW
REF.
SINKD/WEXH. FAN / MICRORANGE.BATHRM25' - 2 1/2"6' - 1 1/2"0' - 5 1/2"JADU UNDER SEPARATE BUILDING PERMIT, NOT PART OF THIS APPLICATION. REFERENCE ONLY2' - 0 1/2"4' - 7"22A1.3
EGRESS DROWNER HAVE DESIGNATED AND ALLOCATED THIS AREA TO BE A CELLAR 22JADU UNDER SEPARATE BUILDING PERMIT, NOT PART OF THIS APPLICATION. REFERENCE ONLYFLOOR PLAN KEYNOTESLINEN CLOSET -PROVIDE 5-20" DEEP SHELVES -DETERMINESPACING ON JOB WITH ARCHITECT & CLIENT.BUILT-IN MILLWORK -SEE INTERIOR ELEVATIONS. REFER TO MILLWORK DESIGNUNDERMOUNT FARM SINK, KITCHEN SINK WITHGARBAGE DISPOSAL -SELECTED BY OWNERLAVATORY AND FAUCET -SELECTED BY OWNERGAS RANGE COOKTOP -SEE APPLIANCE & EQUIPMENT SCHEDULE
KITCHEN ISLAND
BAR SINK -SELECTED BY OWNER, SEE DTL .SHOWER HEAD -SELECTED BY OWNERCOUNTER TOP -SELECTED BY OWNER
TOILET-SELECTED BY OWNER
TOILET-PAPER HOLDER -SELECTED BY OWNER
PEDESTAL SINK -SELECTED BY OWNERMIRROR -SEE INTERIOR ELEVATIONS FOR DIMENSIONS
TOWEL BAR TO BE SELECTED -PROVIDE BLKG IN WALL
REFRIGERATOR SPACE, PROVIDE RECESSED BOX FOR WATERLINE & SHUT-OFF VALVE IN WALL FOR ICE MAKER -SEE APPLIANCE & EQUIPMENT SPEC.DISHWASHER -SEE APPLIANCE & EQUIPMENT SCHEDULE
SHOWER SHELF -SELECTED BY OWNERCLOTHES WASHER -PROVIDE PLUMBING & GALVANIZED FLASHING PANUNDER UNIT & RECESSED VALVE AND DRAIN BOX IN WALL SHOWER, SEE DTL. AND , SHOWER SURROUND -SELECTED BY OWNERPULL DOWN ATTIC ACCESS, SEE DTL.
WINE COOLER -SELECTED BY OWNERPROVIDE HOT & COLD WATER ROUGH-IN FOR N.I.C.WATER SOFTENER CLOTHES ROD WITH 12" DEEP FIXED SHELF ABOVE, SEE DTL.WALK-IN BATH TUB EQUIPPED WITH EXTENSION BOX TO FIT OPENING, SEE DTL. HANDRAIL -SEE DTL.
PANTRY SHELVES -PROVIDE ADJUSTABLE SHELVES
ROOF LINE ABOVE
GAS FIREPLACE -SELECTED BY OWNER
TEMPERED GLASS SHOWER SCREEN & DOOR
CRAWL SPACE VENTILATION AREAWAY -EXISTING LOCATION
PROVIDE NEW TEMPERED SHOWER GLASS DOOR WITH TOWEL BAR
CABINET SYSTEMS -N.I.C. TO BE PROVIDED & INSTALLED BY OWNER
DOWNSPOUT
BUILT-IN MICROWAVE & OVEN -SELECTED BY OWNER
UNDERCOUNTER LAZY SUSAN UNIT
TEMPER GLASS PANEL DOORCLOTHES DRYER -PROVIDE VENT TO EXTERIOR WITH BACKDRAFT DAMPER IN ACCORDANCE WITH CMC 504.3.2 -SEE APPLIANCE & EQUIPMENT SCHEDULEADJUSTABLE SHOWER HEAD W/HANDSHOWER -SELECTED BY OWNER
BUILT-IN CABINET FOR TELEVISION 1.ALL FLOOR PLAN DIMENSIONS ARE FROM FACE OF STUD TO FACE OF
STUD, U.O.N. WHERE CLEAR DIMENSION IS INDICATED, IT SHALL BE FROM
FACE OF FINISH TO FACE OF FINISH. WHERE CENTERLINE DIMENSION IS
INDICATED, IT SHALL BE FROM CENTERLINE OF OBJECT NOTED.2.CONTRACTOR TO PROVIDE RECESSED BOXES BEHIND ALL REFRIGERATORS ICE-MAKERS & WATER LINE AND WASHER/DRYER. CAULKING ALL AROUND RECESSED BOXES3.REFER TO PROJECT INFORMATION SHEET FOR ROOF/ATTIC &
UNDERFLOOR VENTILATION CALCULATIONS.4.PROVIDE FLOORING TRANSITION STRIP BETWEEN DISSIMILAR MATERIALS.5.MECHANICAL & PLUMBING VENTS THROUGH EXTERIOR WALLS SHALL BEEQUIPPED WITH WALL CAP, BUILT-IN BACKDRAFT DAMPER & BIRD SCREEN.WILDLAND URBAN INTERFACE FIRE HAZARD AREAA. EXTERIOR WALL COVERING ARE CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS.B. EXTERIOR WALL VENTS (CRAWL SPACE VENTS, COMBUSTION AIR VENTS, ETC.)SPECIFY SUCH OPENING SHALL BE COVERED W/CORROSION-RESISTANT NON-COMBUSTIBLE WIRE MESH WITH MESH OPENINGS OF 1/8 INCH MAX. PER CRC R337.6.2.6.FOR ROOM FINISHES, SEE ROOM FINISH SCHEDULE SHEET 7.SEE INTERIOR ELEVATION SHEETS FOR MOUNTING HEIGHTS
OF BATHROOM ACCESSORIES, COUNTERTOP HEIGHTS.8.SEE SHEET A-0.1 FOR ABBREVIATIONS, LEGENDS, SYMBOLS.9.WHERE DOOR LOCATIONS ARE NOT SPECIFIED, CENTER IN WALL OR
INSTALL 4" FROM FACE OF ADJACENT WALL FRAMING.10. ALL INTERIOR WALLS TO BE WALL TYPE C U.O.N. -SEE WALL LEGEND.FLOOR PLAN NOTES11.EACH BEDROOM AND OUTSIDE SLEEPING AREA, PROVIDED WITH A SMOKE AND CARBON MONOXIDE DETECTORS INSTALLED IN A ACCORDANCE WITH CRC. R.315 CARBON MONOXIDE ALARMS COMBINED WITH SMOKE SHALL COMPLY WITH SECTION R315, ALL APPLICABLE STANDARD, AND REQUIREMENTS FOR LISTING AND APPROVAL BY THE OFFICE OF THE STATE FIRE MARSHAL, FOR SMOKE ALARM.0102030405060708091011121314151617181920MILLWORK FINISH TO BE SELECTED BY OWNER -SEE INTERIOR ELEVATIONS2122
UNDERMOUNT VANITY SINK -SELECTED BY OWNER2324WALL-MOUNTED RANGE HOOD -SEE APPLIANCE & EQUIPMENTSCHEDULE252627282930323133343536LAUNDRY SINK -SELECTED BY OWNER373839404142434445ROOF VENT (VENTILATION) OHAGIN 72 SQ.IN. NFVA. OR EQUAL, SEE DTL. 46PATIO DECK CONCRETE OR COMPOSITE ASSEMBLY BY TREX OR EQUAL. COLOR TO BE SELECTED BY OWNER. (TO BE DETERMINED BY OWNER).47CONCRETE SLAB48
PRE-FABRICATED COLUMN COVER, SEE DTL.
COLUMNS MDO WITH STONE VENEER BASE, SEE DTL. FIRST Lvl1' -8"BASEMENT Lvl-8' -4"GRADE Lvl0' -0"B144" MAX.4' - 0"R310.1 EMERGENCY ESCAPE AND RESCUE OPENING
REQUIREDBASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE NOT LESS THAN ONE OPERABLE
EMERGENCY ESCAPE AND RESCUE OPENING. WHERE
BASEMENTS CONTAIN ONE OR MORE SLEEPING ROOMS,
AN EMERGENCY ESCAPE AND RESCUE OPENING SHALL
BE REQUIRED IN EACH SLEEPING ROOM. EMERGENCY
ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY
INTO A PUBLIC WAY.
EMERGENCY ESCAPE AND RESCUE OPENINGS ARE NOT
REQUIRED FROM BASEMENTS OR SLEEPING ROOMS
THAT HAVE AN EXIT DOOR OR EXIT ACCESS DOOR THAT
OPENS DIRECTLY INTO A PUBLIC WAY OR TO A YARD,
COURT OR EXTERIOR EGRESS BALCONY THAT OPENS TO A PUBLIC WAY.AN EGRESS LADDER OR STEP MAY ENCROACH INTO
WELL UP TO 6". STEPS AND/OR DISTANCE BETWEEN
RUNGS OF THE LADDER CAN'T EXCEED 18". THE RUNGS
OF AN EGRESS LADDER MUST BE 12" WIDE OR GREATER
AND MUST PROJECT A MINIMUM OF 3" AWAY FROM THE
BACK WALL, BUT CAN'T EXCEED 6" FROM THE BACK OF THE WALL.LADDER BOLT TO CONCRETE WALLDRAIN CONNECTION TO FOUNDATIONGRADE @ REAR0' -11 3/8"3' - 8"SHEETOFSHEET TITLECOPYRIGHT:
PROJECT NO:CAD DWG FILE:DRAWN BY:CHK'D BY:DESCRIPTIONDATEMARKOWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com408.843.8067 c2023JER DESIGN GROUPY:\Shared\Project's\15411National Ave. LosGatos\DWG'S\240610 - Rev.Ramya Resi.rvtPLANNING 20109242VYANKATESH B. & RAMYAMUDDADA RES.424-12-140AuthorChecker15411 NATIONAL AVE. LOS GATOS, CA.A1.3BASEMENT Lvl424-12-1401/4" = 1'-0"1BASEMENT Lvl
3/8" = 1'-0"2BASEMENT SECTION EGRESS2CELLAR : 1, SF.JADU : 500 SF.209/03/2024
200
A4.0 2
A4.1
1
3 4 5 6
B1
C1
E1
A4.1
2
A1
D1
1
A2.1
2
A2.1
1 2
A4.01-
---
3
A2.1
SOLATUBE
DETAIL
SOLATUBE
DETAIL
SOLATUBE
DETAIL
4" / 1'-0"4" / 1'-0"
4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"4" / 1'-0"SOLATUBE
DETAIL
2
A1.3 1' - 3 1/2"0' - 4"1' - 5 1/2"1' - 5 1/2"2' - 3 1/2"ROOF CLASS A
ASSEMBLY
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A1.4 MAIN STRUCT -ROOF PLAN424-12-1401/4" = 1'-0"1 PLATE HT.
09/03/2024
FIRST Lvl
1' -8"
SECOND Lvl
12' -10"
BASEMENT Lvl
-8' -4"
PLATE HT.
22' -10"
B1 C1 E1A1D1
U.S.S.
11' -8"8' - 8 1/2"ROOF RIDGE
30' -0"
311.44'
322.61'
332.61'
339.77'29' - 0 1/2"28' - 4"0' - 8 1/2"303.10'
310.77'
TOP OF 2X6 PLUS
BOTT. OF 2X8 RAFTER
NON-HABITABLE SPACE AND WE ARE UNDER
THE MAX. HT. OF 7'-6" non-habitable6' - 11 1/2"2
FIRST Lvl
1' -8"
SECOND Lvl
12' -10"
BASEMENT Lvl
-8' -4"
PLATE HT.
22' -10"
GRADE Lvl
0' -0"
3 4 5 612
U.S.S.
11' -8"
ROOF RIDGE
30' -0"
GRADE @ REAR
0' -11 3/8"
311.44'
322.61'
332.61'
339.77'
303.10'
310.77'
309.78'
2
2
2 7' - 2"10' - 0"11' - 2"1' - 8"MAX.HT.30' - 0"5
FIRST Lvl
1' -8"
BASEMENT Lvl
-8' -4"
B1A1
OPENING7' - 6"8' - 8 1/2"1' - 3 1/2"6' - 10 1/2"SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvt
PLANNING 20109242VYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A2.1 BUILDING SECTIONS424-12-1401/4" = 1'-0"1 Section 1
1/4" = 1'-0"2 Section 4
1/4" = 1'-0"3 Section 12
1/4" = 1'-0"4 Section 15
09/03/2024
FIRST Lvl
1' -8"
SECOND Lvl
12' -10"
BASEMENT Lvl
-8' -4"
PLATE HT.
22' -10"
GRADE Lvl
0' -0"
U.S.S.
11' -8"
ROOF RIDGE
30' -0"
SLOPE 2%
339.77'
332.61'
311.44'
309.69'
303.10'PROPERTY LINESTRUCTURE SETBACKSTRUCTURE SETBACKPROPERTY LINE25' - 0 1/2"20' - 1"
322.61'
EXISTING GRADE
TO BE GRADED
310.65'
310.77'
311.44'
309.40'
SLOPE 2%
309.94'30' - 0"FIRST Lvl
1' -8"
SECOND Lvl
12' -10"
BASEMENT Lvl
-8' -4"
PLATE HT.
22' -10"
GRADE Lvl
0' -0"
U.S.S.
11' -8"
ROOF RIDGE
30' -0"PROPERTY LINESTRUCTURE SETBACKSTRUCTURE 8'-0"PROPERTY LINESETBACK
8' - 0"
STRUCTURE SETBACK
26' - 9 1/2"
PROPOSED DRIVEWAY GARAGE LIVING
BASEMENT
LIVING
ATTIC
339.77'
332.61'
311.44'
309.77'
303.10'
322.61'1' - 8"SLOPE 5%SLOPE 5%
309.77'
309.27'
309.02'309.35'27' - 5"SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A3.1 SITE SECTION424-12-1403/16" = 1'-0"1 SITE SECTION
3/16" = 1'-0"2 SITE SECTION 02
09/03/2024
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
ELEVATION KEYNOTES LEGEND
FASCIA BOARD
LIGHTWEIGHT CONCRETE TILES - TILE OR EQUAL.
ROOFING SHALL BE RATED CLASS "C" MIN., WITH ALL
CORROSION RESISTANT FASTENERS
GALVANIZED SHEET METAL DOWNSPOUT.
PAINT TO MATCH ADJACENT WALL
VALLEY FLASHING ON ROOF
CEMENT PLASTER : SAND FLOAT FINISH
ADDRESS NUMBER. MIN. 4" HIGH WITH CONTRASTING
COLOR TO BACKGROUND
WIDE GALVANIZED SHEET METAL GUTTER.
PAINT TO MATCH TRIM
MARVIN WINDOW OR SEQUEL SELECTED BY OWNER
DECORATIVE WOOD BRACKET. SEE DETAIL
IRON DOOR OR NANO, PRODUCT TO BE EQUAL
TRIM AROUND WINDOWS, DOORS & OPENING TO
MATCH BASE, PRECAST PROFILE TO BE SELECTED BY
OWNER
TOP OF LIGHT FIXTURE MOUNTED ON A TRIM TO
MATCH WINDOW AND OPENING SELECTION
CONTROL JOINT, TYP.
PRECAST CONCRETE TREADS.
SEE DETAILS
STAIN COLUMNS
CONCRETE STEPS, TRAVERTINE TILES TO MATCH
@ PLATFORM LARGE FORMAT TILES
22
ATTIC ROOF VENT. SEE DETAIL
23
24
26
STUCCO BASE CONT. (PROJECTED)
GAS METER & ELEC. METERS - SEE SITE PLAN
6' GOOD NEIGHBOR FENCE FOR PRIVACY, SEE DTL
STEPPED FOUNDATION WALL - S.S.D. & CIVIL DWGS
STONE VENEER (EL DORADO) MAX. DEPTH TO BE 1"
ALUMINUM GARAGE W/POLYURETHANE INSULATION R-
VALUE. DOOR TO BE SELECTED BY OWNER.
WALL CAP (OWNER TO SELECT TYPE & FINISH)
25 WOOD PLANKS AT UNDERSIDE OF STRUCT. STAIN TO
MATCH EXT. COLUMNS STAIN COLOR TO BE
SELECTED BY OWNER
27 IRON DOORS AND ACCENT ELEMENTS
28 PAVERS, COLOR AND SIZE TO BE SELECTED BY
OWNER
29 LARGE BOWL PLANTER, LANDSCAPE TO HAVE WATER
DRIP CONNECTION. COLOR AND SIZE TO BE
SELECTED BY OWNER
30 CONTROL JOINT TO BE PAINTED TO MATCH ADJACENT
SURFACE
STANDING SEAM ROOF DARK-BRONZE
31 SIDING BOARD
BALLY BAND TO MATCH TRIM AT DOORS AND
WINDOWS32
SUN TUBE TO MATCH COLOR OF TILE (SELECTED BY
OWNER)
33
SKYLIGHT (SELECTED BY OWNER)34
35
FIRST Lvl
1' -8"
SECOND Lvl
12' -10"
PLATE HT.
22' -10"
GRADE Lvl
0' -0"
B1C1E1 A1D1
U.S.S.
11' -8"
1
6 6
14
13
32
13
13
32
26
20
26
1
TOP OF RIDGE LINE
7' - 2"10' - 0"1' - 2"10' - 0"1' - 8"3' - 1 1/2"1
27
3333
19
33
19
1
5
4
1
1
9
309.78'
311.44'
322.61'
332.61'
339.77'
ROOF RIDGE
30' -0"MAX.30' - 0"2
GRADE @ REAR
0' -11 3/8"4' - 7"TOP OF RIDGE LINE
TOP OF RIDGE LINE
3' - 3"7' - 0 1/2"10' - 6 1/2"TOP OF RIDGE LINE
FIRST Lvl
1' -8"
SECOND Lvl
12' -10"
PLATE HT.
22' -10"
B1 C1 E1A1D1
U.S.S.
11' -8"
30
12
20
20
26
TOP OF RIDGE LINE
4' - 6"10' - 0"1' - 2"10' - 0"TOP OF RIDGE LINE
2
33
5
7
13
11
2
33
19
34
ROOF RIDGE
30' -0"
311.44'
322.61'
332.61'
339.77'
310.73'
GRADE @ REAR
0' -11 3/8"26' - 4 1/2"21' - 10 1/2"2 1 /8 " / 1 '-0 "
4" / 1'-0"
2 1/8" / 1'-0"
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvt
PLANNING 20109242VYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A4.0 PROPOSED BUILDING ELEVATIONS424-12-1401/4" = 1'-0"1 FRONT ELEVATION
1/4" = 1'-0"2 REAR ELEVATION
1
1
09/03/2024
PLAIN FROSTED, LIGHT DIFFUSE & ETCHED WINDOW FILM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
ELEVATION KEYNOTES LEGEND
FASCIA BOARD
LIGHTWEIGHT CONCRETE TILES - TILE OR EQUAL.
ROOFING SHALL BE RATED CLASS "C" MIN., WITH ALL
CORROSION RESISTANT FASTENERS
GALVANIZED SHEET METAL DOWNSPOUT.
PAINT TO MATCH ADJACENT WALL
VALLEY FLASHING ON ROOF
CEMENT PLASTER : SAND FLOAT FINISH
ADDRESS NUMBER. MIN. 4" HIGH WITH CONTRASTING
COLOR TO BACKGROUND
WIDE GALVANIZED SHEET METAL GUTTER.
PAINT TO MATCH TRIM
MARVIN WINDOW OR SEQUEL SELECTED BY OWNER
DECORATIVE WOOD BRACKET. SEE DETAIL
IRON DOOR OR NANO, PRODUCT TO BE EQUAL
TRIM AROUND WINDOWS, DOORS & OPENING TO
MATCH BASE, PRECAST PROFILE TO BE SELECTED BY
OWNER
TOP OF LIGHT FIXTURE MOUNTED ON A TRIM TO
MATCH WINDOW AND OPENING SELECTION
CONTROL JOINT, TYP.
PRECAST CONCRETE TREADS.
SEE DETAILS
STAIN COLUMNS
CONCRETE STEPS, TRAVERTINE TILES TO MATCH
@ PLATFORM LARGE FORMAT TILES
22
ATTIC ROOF VENT. SEE DETAIL
23
24
26
STUCCO BASE CONT. (PROJECTED)
GAS METER & ELEC. METERS - SEE SITE PLAN
6' GOOD NEIGHBOR FENCE FOR PRIVACY, SEE DTL
STEPPED FOUNDATION WALL - S.S.D. & CIVIL DWGS
STONE VENEER (EL DORADO) MAX. DEPTH TO BE 1"
ALUMINUM GARAGE W/POLYURETHANE INSULATION R-
VALUE. DOOR TO BE SELECTED BY OWNER.
WALL CAP (OWNER TO SELECT TYPE & FINISH)
25 WOOD PLANKS AT UNDERSIDE OF STRUCT. STAIN TO
MATCH EXT. COLUMNS STAIN COLOR TO BE
SELECTED BY OWNER
27 IRON DOORS AND ACCENT ELEMENTS
28 PAVERS, COLOR AND SIZE TO BE SELECTED BY
OWNER
29 LARGE BOWL PLANTER, LANDSCAPE TO HAVE WATER
DRIP CONNECTION. COLOR AND SIZE TO BE
SELECTED BY OWNER
30 CONTROL JOINT TO BE PAINTED TO MATCH ADJACENT
SURFACE
STANDING SEAM ROOF DARK-BRONZE
31 SIDING BOARD
BALLY BAND TO MATCH TRIM AT DOORS AND
WINDOWS32
SUN TUBE TO MATCH COLOR OF TILE (SELECTED BY
OWNER)
33
SKYLIGHT (SELECTED BY OWNER)34
35
FIRST Lvl
1' -8"
SECOND Lvl
12' -10"
PLATE HT.
22' -10"
GRADE Lvl
0' -0"
3 4 5 61
A2.1
1 2
U.S.S.
11' -8"13' - 5"1
10' - 0"1' - 2"10' - 0"1' - 8"22' - 10"TOP OF RIDGE LINE
10' - 0"1' - 2"10' - 0"0' - 8 1/2"TOP OF RIDGE LINE
25' - 10"1
12
30
20
12
12
33
34
19
3232
2
A1.3
ROOF RIDGE
30' -0"
GRADE @ REAR
0' -11 3/8"
311.44'
322.61'
332.61'
339.77'
310.73'
309.78'
2
2
2
2
A3.1
FIRST Lvl
1' -8"
SECOND Lvl
12' -10"
PLATE HT.
22' -10"
GRADE Lvl
0' -0"
34561
A2.1 12
U.S.S.
11' -8"
2021
1212
1' - 8"10' - 0"1' - 2"10' - 0"1' - 8"10' - 0"1' - 2"10' - 0"3' - 1 1/2"29' - 0 1/2"23
8
8
20
17
17
20
2
A1.3
309.78'
311.44'
322.61'
332.61'
339.77'0' - 11 1/2"310.73'
ROOF RIDGE
30' -0"
2
2
2
0' - 6"310.28'
2 2
2
A3.1
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvt
PLANNING 20109242VYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A4.1 PROPOSED BUILDING ELEVATIONS424-12-1401/4" = 1'-0"1 SOUTH SIDE ELEVATION
1/4" = 1'-0"2 NORTH SIDE ELEVATION
1
1 1
2
09/03/2024
PLAIN FROSTED, LIGHT DIFFUSE & ETCHED WINDOW FILM
3535
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER OR ARCHITECT.
email: jer@jerdesigngroup.com
408.843.8067 c
2019
JER DESIGN GROUP
Y:\Shared\Project's\New
folder\DWG'S\opt. two
elevation Ramya. - Rev.
Two.rvtVYANKATESH B. & RAMUDDADA RES.424-12-137
Author
Checker15415 NATIONAL AVE. LOS GATOS, CA.A4.3 COURTYURD ELEVATIONS / MAT.424-12-137Jose Rama
CONCRETE LIGHT TILES ROOF
140140
Jose Rama
MYAJose Rama
FACADE NATURAL STONE
VENEER MAX. 2" THK
WAINSCOT SILL
FRONT ENTRANCE
MARVIN OR EQUEL SLIDING
DOORS
SMOOTH STUCCO FINISH
SIMPLY ELEGANT APPEARANCE
EXTERIOR WITH WOOD TRIM
MOLDING
WALL MOUNTED SCONCE
ROOF TYPE CLASS A
DOWN-LIGHT
01 231025 PLANNING
01
Jose RamaJose Rama
07/02/2024
EXTERIOR SIDE WINDOW PANELS, ON THE NORTH SIDE
ELEVATION TO BE PLAIN FROSTED, LIGHT DIFFUSING & ETCHED
FILM. THE TWO LOWER PANEL ON BOTH WINDOWS.
WINDOWS PANEL DIFFUSE
09/03/2024
Scale: 1 1/2'' = 1'-0''TYPICAL SCORE JOINT
1/2" TOOLED SCORE LINE
AGGREGATE BASE.
CONCRETE SIDEWALK
@ 5'-0" O.C.0' - 4"CENTER OF SLAB
O.C. EA. WAY AT
#3 DIA. BARS @ 24"
Scale: 1 1/2'' = 1'-0''
TYPICAL EXPANSION JOINT
CONC. SIDEWALK/
CENTER OF SLAB
O.C. EA. WAY AT
#3 DIA. BARS @ 24"
JOINT W/ 1/2"
1/2" FIBER EXP.
AGGREGATE BASE
DRIVEWAY
SEALANT FILL
0' - 4"TYP. NO.8 AGGREGATE IN
OPENING
MIN. 4" THICK NO.57 STONE
OPEN-GRADED BASE
SOIL SUBGRADE
BEDDING COURSE 1.5 TO 2" THICK
TYP. NO.8 AGGREGATE
EDGE RESTRANT METAL OR
PLASTIC / WGALV. SPIKE
GEOTEXTILE AS REQUIRED ON
BOTTOM AND SIDE OF OPEN WITH
DESIGN.
NOTES: ASTM NO.3 OR 4 STONE
MAY BE SUBSTITED FOR NO.2
STONE ASTM NO.89 OR 9 STONE
MAY BE USED IN THE PAVER
OPENING
Scale: 1/2" = 1'-0"PAVERS ASSEMBLY, PERMEABLE
OPT. CURB/EDGE RESTRAINT WITH CUT-
OUTS FOR OVERFLOW DRAINAGE
CONCRETE PAVERS MIN. 3
1/8" THICK
NO.2 STONE SUBBASE -
THCKNESS VARIES W/ DESIGN.ED
BASE1' - 4"0' - 10"1' - 0"
GRADE (E)
PAVERS
B-CAP 2"
6"X16"X8" GROUT
CONC. BLK WALL
#4 TOP
#4 HORZ.
#4 @16" CENTER OF
WALL ALT. BENDSHORZ.
MORTAR
STONE FACADE
OWNERS OPTION
BOTHSIDE
Scale: 1 1/2" = 1'-0"SITE-LOWPONY WALL
PAVING JOINTS (FLUSH)
MIN. 4" COMPACTED AGGREAGE
BASE
95% COMPACTED SUBGRADE
1"-2" MORTAR SETTING BED
GEOTEXTILE AS REQUIRED
MIN. BASE THICKNESS WALKWAY
OR PATIO 6" MIN.
Scale: 1/2" = 1'-0"PAVERS ASSEMBLY, TYP.0' - 6"4"-6"0' - 2"4"-6" CONCRETE SLAB
GOOD NEIGHBOR FENCE
1"x8"
PLANKS
2"x4" CONT.
4x4 POSTS MAX 8'
O.C.
1"x1" CLEATS EA.
SIDE
2"x6" CONT. REDWOOD.TYP
SECTION
12" SQ. 12 GA.
GALV.
BASE W/AB44
REDWOOD
(TYP.)
1"x1" CLEATS EA.
SIDE
12"∅48"
DEEP CONC. FOOTING
OVERLAP
1/2"
P.T.D.F.
2"x8" CONT.
BOTTOM RAIL
ELEVATION 0' - 1 1/2"6' - 0"1' - 0"0' - 1"4' - 10"0' - 1"0' - 2"LATTICE ON TOP, MAX 7'-0"
STONE PAVERS,(SIZE,
PATTERN AND SHAPE ARE
VARIABLE).
2" MORTAR SETTING BED
MIN. BASE THICKNESS WALKWAY
OR PATIO 6" MIN.
Scale: 1/2" = 1'-0"PAVERS ASSEMBLY, PERMEABLE
0' - 6"0' - 6"
6" MIN. COORD. W/ OWENERS
AND LANDSCAPE DESIGNER
(TURF OR GRASS).
MIN. 4" THICK NO.57 STONE
OPEN-GRADED BASE
SOIL SUBGRADE
GEOTEXTILE AS REQUIRED ON
BOTTOM AND SIDE OF OPEN WITH
DESIGN.
NO.2 STONE SUBBASE -
THCKNESS VARIES W/ DESIGN.ED
BASE
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A8.0 DETAILS -SITE424-12-14001
02
03
06
07
1/2" = 1'-0"8 FENCE DETAIL
4
09/03/2024
HEAD FLASHING
(INSTALL OVER JAMB
FLASHING)
FLASHING DETAIL
JAMB
FLASHING
DOOR JAMB
DOOR SEE PAN FLASHING
DETAIL ABOVE
FACE OF WALL
DOOR
DOOR FRAME
SEALANT AT CORNER
JAMB FLASHING
(INSTALL UNDERNEATH
HEAD FLASHING
HEAD FLASHING
CUT INSIDE
CORNER
CUT 1/2"DEEP KERF
26 GA. G.I.
CONTINUOUS PAN
FLASHING, SOLDIER
ALLJOINTS, (NO
COLD
SOLDER JOINTS)
(NOTE: DETAIL
SHOWS
ONE SIDE ONLY)
THIS CORNER MUST FOLD
UNDERNEATH HORIZONTAL
LIP (@ HEAD FLASHING
ONLY)
BEND PROFILE
(TYP. @ HEAD
& JAMB FLASHING)
Scale: N.T.S."
DOOR FLASHING
V .I.F .4 "V.I.F.
4"MIN. VARIES0' - 1"1/8".4"
THRESHOLD PAN FLASHING
1 5/16".90.00°3/16".1/2".1 21/64".Scale: 3" = 1'-0"
WALL TYPE AS
INDICATED ON FLOOR
PLANS
INTERIOR DOOR HEAD/JAMB SIM.
DOOR TRIM @ HEAD / CORNER
6" HEAD
TRIM
6" JAMB
CASING
DOOR
DOUBLE 2x4 STUDS @ DOOR JAMB
HEADER @ DOOR HEAD
SHIM
DOOR FRAME
WOOD TRIM ACCENT TRIM AT
HEAD. & JAMB TYP. TO MATCH
FLOOR 0' - 0 1/2"CONT. Z-SHADOW BEAD ALUMN.-STR PRIME
PAINTED
CONT. Z-
BEAD
10" BASE 10" BASEFULLY SOLDER ALL FOUR
PLANES ATM JOINT, TYP.
Scale: 3/4" = 1'-0"
TWO PIECE
FLASHING
SHEET METAL PAN ISOMETRIC
TYP. OPER. WINDOW/DR JAMB @ STONE
SCALE : 3" = 1'-0"
Grid
POINTING SEALANT ,TYP.
METAL FLASHING
OVER SAF
SAF AROUND ALL
CORNERS UPTO JAMB
DOUBLE 2x
STUDS
5/8" GYP. BD.
F-R PLYWD.
SHEATHING
INSUL.R19
SEE T-24
WRB
WINDOW MUST BE INSTALLED ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS
AND MUST ALLOW FOR PROPER INSTALLATION OF THE FINISHED SILLS AND JAMBS.
BEDDING MASTIC OR
FOAM TAPE PER MFR0' - 2"0' - 6"LAP
0' - 4" SAF 0' - 3"
2X WD. STUD
FRAMING AT WALL
FIN. WD STOOL
STONE SILL SLOPED
TO DRAIN
STEEL CSMT
WINDOW/OUTSWING
DR AS SCHEDULED
MECH. FASTENER AT
JAMB END
0' - 2 1/2"0' - 1"0' - 3"WRB INSULATION, SEE
TITLE 24 REPORT
1/2" PLYWOOD SHEATHING -S.S.D
( FIRE RETARDANT AT STONE
VENEER ONLY)
5/8" GYP. BD.
Scale: 3" = 1'-0"
WINDOW SILL @ STONE VENEER
SECTION
LIMESTONE SILL W/TOP
SLOPED TO DRAIN
RAKED JOINT, TYP.
TERMINATE METAL LATH AT J-
BEAD ABOVE
GSM FLASHING OVER SILL TO
MATCH WINDOW
CONT BEAD OF SEALANT
GRID
0' - 3"
1/4".
STEEL WINDOW
SYSTEM W/SILL
ANCHORED TO
SUBSILL PER
MFR SPECS
METAL SUBSILL ANCHORED TO
WD. FRAMING PER MFR. SPEC
SAF AROUND ALL CORNERS
UNDER WRB
POINTING SEALANT , TYP.MIN. LAP0' - 4"EXTERIOR
FIN. WD.
HEADER &
JAMB
SILL/STOOL
W2 WALL
ASSEMBLY
INTERIOR
WRB LAP OUTER LAYER OVER
FLASHING
STONE VENEER ON MORTAR
BED - SEE WALL TYPEINSULATION
PER T-24
1/2" FIRE RETARDANT PLYWOOD
SHEATHING, EXT GRADE
(ALSO S.S.D. FOR SHEAR WALLS)
5/8" GYP. BD.
Scale: 3" = 1'-0"DOOR HEAD W/CEDAR TRIM
SECTION 0' - 11 1/2"SAF BEHIND WRB AT BENDS,TYP.MIN. LAP0' - 4"NOTCHED DRIP
SEALANT W/ BACKER ROD, TYP.
STL DOOR AS
SCHEDULED
PAINTED CEDAR TRIM
FOR FAUX LINTEL
EXTERIOR
SEALANT W/ BACKER ROD
SAF BEHIND WRB
AT BENDS,TYP.
2X CONT
WD. BLKG
WD.
HEADER -
S.S.D
DBL 2X10
SHAVED AS
NECESSARY
FOR FIN. DIMS.
0' - 3"
GRID
GSM FLASHING LAP MIN 4" MIN. LAP0' - 4"DOOR JAMB W/STONE VENEER
SCALE : 3" = 1'-0"
Grid
POINTING SEALANT ,TYP.
METAL FLASHING
OVER SAF
SAF AROUND ALL
CORNERS UPTO JAMB
DOUBLE 2x
STUDS
5/8" GYP. BD.
F-R PLYWD.
SHEATHING
INSUL.R19
SEE T-24
WRB
WINDOW MUST BE INSTALLED ACCORDING TO THE MANUFACTURER'S SPECIFICATIONS
AND MUST ALLOW FOR PROPER INSTALLATION OF THE FINISHED SILLS AND JAMBS.
BEDDING MASTIC OR
FOAM TAPE PER MFR
LAP
0' - 4" SAF 0' - 3"
2X WD. STUD
FRAMING AT WALL
FIN. WD STOOL
STONE SILL SLOPED
TO DRAIN-FLUSH
STEEL INSWING DR
AS SCHEDULED
MECH. FASTENER AT
JAMB END
0' - 1"0' - 2 1/2"0' - 3"0' - 6"INTERIOR
STONE VENEER ON MORTAR
BED - SEE WALL TYPE
INSULATION
PER T-24
1/2" FIRE RETARDANT PLYWOOD
SHEATHING, EXT GRADE
(ALSO S.S.D. FOR SHEAR WALLS)
5/8" GYP. BD.
Scale: 3" = 1'-0"DOOR HEAD W/STONE TRIM
SECTION 0' - 11 1/2"SAF BEHIND WRB AT BENDS,TYP.
NOTCHED DRIP
SEALANT W/ BACKER ROD, TYP.
STL DOOR AS
SCHEDULED
EXTERIOR
SAF BEHIND WRB AT
BENDS,TYP.
WD.
HEADER -
S.S.D
2X SHAVED AS
NECESSARY
FOR FIN. DIMS.
GRID
W2 WALL
ASSEMBLY
INTERIOR
WRB LAP OUTER LAYER OVER
FLASHING
STUCCO OVER LATH - SEE
WALL TYPEINSULATION
PER T-24
1/2" FIRE RETARDANT PLYWOOD
SHEATHING, EXT GRADE
(ALSO S.S.D. FOR SHEAR WALLS)
5/8" GYP. BD.
Scale: 3" = 1'-0"DOOR HEADER @ STUCCO
SECTION 0' - 11 1/2"SAF BEHIND WRB AT BENDS,TYP.
NOTCHED DRIP
SEALANT W/ BACKER ROD, TYP.
STL DOOR AS
SCHEDULED
EXTERIOR
BEDDING SEAL UNDER GSM
WD.
HEADER -
S.S.D
VENEER STONE
GRID
GSM FLASHING LAP MIN 4" 6". LAPLAP WRB OVER
SCREED
/ WEEP
STUCCO
WRB
GSM FLASHING
WEEP SCREED
SEAL UNDER GSM
W1 WALL
ASSEMBLY
Scale: 3" = 1'-0"
± 7'-0"
GARAGE DOOR HEAD (JAMB SIM.)
2x P.T. CEDAR TRIM
HEADER, S.S.D.
SECTIONAL GARAGE DOOR
STAINED FIRE RETARDANT
(ICC REPORT # ESR-1159
TRACK
POLYVINYL WEATHERSTRIP
WALL ASSY W-6a
JAMBS & HEAD0' - 0 1/2" OVERLAPFLOOR FINISH
26 GA. G.S.M.
WEEPSCREED
PLYWD. SHEATHING
S.S.D.
PRESERVATIVE-TREATED
SILL PLATE, S.S.D.
EXT. WALL SEE PLAN
WRB
STONE VENEER ON 1/2"
MORTAR BED ON 3/8"
SCRATCH COAT OVER
MET. LATH
FLR. LINE OR FOUNDATIONS.S.DNOTE : SEE STRUCTURAL DWGS FOR FOUNDATION/FOOTING
SILL GASKET
MEMBRANE /
CAPILLARY BREAK
Scale: 3" = 1'-0"
STONE VENEER @ SILL
MORTAR SETTING BED
OVER MORTAR SCRATCH
COAT
FLASHING SLOPED TO
EXTERIOR
FLASHING TRANSITION
EXTENDED MIN. 2" BELOW
TOP OF FOUNDATION
WALLMIN.0' - 1 1/2"WINDOW TRIM EXTERIOR
EXT TRIM AROUND
WINDOW UNIT
WINDOW
SCALE:1/2"=1'-0"
0' - 5 1/2"0' - 6 1/2"0' - 5 1/2"0' - 5 1/2"SLOPED SILL
WINDOW TRIM INTERIOR
WD. TRIM AROUND
WINDOW
WINDOW
SCALE:1/2"=1'-0"0' - 4 1/2"0' - 4"0' - 4"0' - 4"
OPTION ONE
OPTION TWO
SHEET OF
SHEET TITLE
COPYRIGHT:
PROJECT NO:
CAD DWG FILE:
DRAWN BY:
CHK'D BY:
DESCRIPTIONDATEMARK
OWNER
ALL DRAWINGS AND WRITTEN MATERIAL
APPEARING HEREIN ARE THE ORIGINAL
AND UNPUBLISHED WORK OF THE
DESIGNER, AND MAY NOT BE COPIED OR
USED WITHOUT THE WRITTEN CONSENT
OF THE DESIGNER.
email: jer@jerdesigngroup.com
408.843.8067 c
2023
JER DESIGN GROUP
Y:\Shared\Project's\15411
National Ave. Los
Gatos\DWG'S\240610 - Rev.
Ramya Resi.rvtVYANKATESH B. & RAMYAMUDDADA RES.424-12-140
Author
Checker15411 NATIONAL AVE. LOS GATOS, CA.A8.2 WINDOW DETAILS424-12-14018
19
16
06
08
01
07
02
05
0310
09/03/2024