Loading...
Attachment 6 - Development PlansSITE PLAN, PROPOSED, KEYNOTES 1 PROPOSED LANDSCAPING RETAINING WALL, CONCRETE ELECTRICAL METER/ PANEL GAS METER TRASH ENCLOSURE, CMU, 2Y GARBAGE, 1.5Y RECYCLE & COMPOST, SEPARATE PERMIT WITH FIRE SPRINKLER EXTERIOR MECHANICAL UNITS DRY STACK RETAINING WALL KNOX BOX OUTDOOR DECK/DINING WITH TRELLIS AND STRING LIGHTS (E) STREET TREE, CALIFORNIA BAY, DIAMETER 18" WITH PROTECTIVE FENCING, SEE TREE PROTECTION AND FENCING NOTES, ROOFTOP VENT HOOD MAKE-UP AIR UNIT, SEE MEP PLANS FIRE DEPARTMENT CONNECTION SCREEN, VERTICAL SIDING AND COLOR TO MATCH ADDITION (P) WATER METER 2 3 4 5 7 LEGEND CO POWER POLE TETHER CLEAN OUT HYDRANT SETBACK LINE PROPERTY LINE BUILDING FOOTPRINT 8 SITE PLAN NOTES: 1. 2. 3. IF ANY EXCAVATION EXCEEDS 5-FEET IN DEPTH OR REMOVES LATERAL SUPPORT FROM AN EXISTING BUILDING, AN ADJACENT PROPERTY, OR THE PUBLIC RIGHT OF WAY, THE PROJECT WILL HALTED UNTIL SHORING PLANS AND CALCULATIONS PREPARED BY A CA LICENSED ENGINEER ARE PROVIDED TO THE TOWN OF LOS GATOS BUILDING DIVISION FOR REVIEW AND APPROVAL. PROJECT MAY RESUME CONSTRUCTION ONCE SHORING PLANS HAVE BEEN APPROVED FOR CONSTRUCTION AND INSTALLED ACCORDING TO APPROVED PLANS. CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF UTILITIES, SITE CONDITIONS, DIMENSIONS, STRUCTURES PRIOR TO START OF WORK. IN EVENT OF ANY DISCREPANCIES OR POTENTIAL CONFLICTS, NOTIFY THE ARCHITECT IN WRITING PRIOR TO STARTING EACH PORTION OF THE WORK. ESTIMATED CUT 0 CY/ FILL 29 CY 9 10 RIGHT-OF-WAY DEDICATION (SEE CIVIL) (P) TRUNCATED DOME (P) ACCESSIBLE PATH OF TRAVEL 11 12 1. 2. 3. 4. NOTES DOCUMENTATION SHALL BE PROVIDED, PRIOR TO FIRST INSPECTION, CONFIRMING COMPLIANCE TO THE WASTE MANAGEMENT PLAN PROVIDED TO THE JURISDICTION. CGBSC SECTION 5.408.1.4 ALL ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AND AEROSOL PAINT CONTAINERS MUST REMAIN ON THE SITE FOR FIELD VERIFICATION BY THE BUILDING INSPECTOR. CGBSC SECTION 5.504.4.3.2 PRIOR TO FINAL INSPECTION, A LETTER SIGNED BY THE GENERAL CONTRACTOR OR THE OWNER/BUILDER (FOR ANY OWNER/BUILDER PROJECTS) MUST BE PROVIDED TO THE TOWN OF LOS GATOS BUILDING OFFICIAL CERTIFYING THAT ALL ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AEROSOL PAINTS, AEROSOL COATINGS, CARPET SYSTEMS (INCLUDING CARPETING, CUSHION AND ADHESIVE), RESILIENT FLOORING SYSTEMS, AND COMPOSITE WOOD PRODUCTS INSTALLED ON THIS PROJECT ARE WITHIN THE EMISSION LIMITS SPECIFIED IN CGBSC SECTION 5.504. HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT SHALL NOT CONTAIN CFCS OR HALONS. CGBSC SECTION 5.508.1 13 14 /4 A001.1 W 15PARK AVENUEE MAIN STREET CO N o r t h11'-6"R/W DEDICATION 262 SF57'-4" REAR SETBACK3 2 4 0' - 0" -1' - 6" 5 7 (E) O.H. TEAT HE R P.L 26.12'P.L 120.96' 0' SETBACKP.L 120.50' 0' SETBACKP.L 26.08'10'-0"TENANT IMPROVEMENT 2,153 SF 9 27'-10"ADDITION 128 SF 11 1 3'-1" -2' - 6" 8 10 1" / 12"1" / 12"FRONT SB1'-6"10'-0"10'-0" 2'-6"PAVERS8'-4"12 6'-3" 13 3'-9" 10'-0" MIN 14 15W 3'-0"MUA 10'-0" MIN PROJECT LOCATION PARK AVE W M A I N S T S SANTA CRUZ AVEBR O A D W A YN SANTA CRUZ AVEW M A I N S T UNIVERSITY AVELUNDY LNMAPLE PLCOLLEGE AVEPAGEANT WAYE MAIN STHWY 17HWY 17ATTS LAC E FO ILICENS E D ARCHIT ECTF O RNIAGORD KONW GNO RENEWAL 03/01/2013 4 0 4 53-C 25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025 Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/17/2024 10:36:09 AM As indicated A000. Site Plan, ProposedSite Plan, ProposedRevision Schedule Number Description Date 1 Planning 2022.10.19 2 Planning 2023.03.17 3 Planning 2023.05.02 6 Building Date 6 7 Plng Historical 2024.06.07 SCOPE OF WORK • • • TENANT IMPROVEMENT 2,153 SF 1ST FLOOR1,073 SF 2ND FLOOR 1,080 SF ADDITION128 SF SITE ADJUSTMENTS OUTDOOR DECK 361SF, TRELLIS AND STRING LIGHTS LANDSCAPING PER COMMERCIAL DESIGN GUIDELINES TRASH ENCLOSURE PROJECT INFORMATION 25 WEST MAIN ST. C A L I F O R N I AL O S G A T O S VICINITY MAP PROJECT LOCATION: APN: PROJECT JURISDICTION: ZONING: GENERAL PLAN USE: (E) / (P) OCCUPANCY: (E) USE / (P) USE: YEAR BUILT/OCCUPIED: GROSS LOT SIZE: NET LOT SIZE: AVG. SLOPE OF LOT: RIGHT-OF-WAY DEDICATION: (E)GROSS FLOOR AREA: 1ST LVL: 2ND LVL: (P) GROSS FLOOR AREA: 1ST LVL: 1ST LVL ADDITION: 2ND LVL: FAR: ALLOWED: EXISTING: PROPOSED: REQUIRED PARKING: RESTAURANT 2,281 SF(1/300 SF) PROPOSED PARKING PARKING DISTRICT SPACES CONSTRUCTION TYPE FIRE SPRINKLERS: SET BACKS FRONT: SIDE: REAR: STREET SIDE: MAX. HEIGHT: (E) & (P) HEIGHT: 25 W MAIN STREET, LOS GATOS, CA 95030 529 - 01 - 017 LOS GATOS C-2: LHP CENTRAL BUSINESS DISTRICT (LOS GATOS HISTORICAL COM. DISTRICT) CENTRAL BUSINESS DISTRICT M / A-2 RETAIL / RESTAURANT 1901 3,133 SF 2,871 SF 6% 262 SF 2,170 SF 1,090 SF 1,080 SF 2,281 SF 1,073 SF 128 SF 1,080 SF FLOOR AREA / LOT SIZE 60 % = 1,880 SF / 3,133 SF 69 % = 2,170 SF/ 3,133 SF 79 % = 2,281 SF/ 2,871 SF 8 7 (1 SPACE REQUEST FOR PARKING VARIANCE) V-B YES (REQUIRED / EXISTING / PROPOSED) 10'-0" / 11'-9" / 1'-6" 0'-0" / 0'-0" / 0'-0" 0'-0" / 61'-8" / 57'-4" 10'-0" / 0'-0" / 0'-0" 45'-0" 21'-11" THIS PROJECT PROPOSES A TENANT IMPROVEMENT FOR A RESTAURANT (2,153 SF) AND ADDITION (128 SF) TO THE HISTORIC TWO-STORY BUILDING. SCOPE INCLUDES A NEW CIRCULATION SPACE WITH A STAIRWAY AND ACCESSIBLE SITE UPGRADES. THE OCCUPANCY/USE TO CHANGE FROM (M) MERCANTILE, TO (A-2) ASSEMBLY. OWNER: PROJECT DIRECTORY REVEAL 004 LLC 675 NORTH FIRST STREET, SUITE 550 SAN JOSE CA 95112 408-314-0077 I INFO@REVEALCORP.COM ARCHITECT:GKW ARCHITECTS, INC. 710 E. MCGLINCY LANE SUITE 109 CAMPBELL, CA 95008 408-315-2125 I GORDONKWONG@GKWARCHITECTS.COM CIVIL ENGINEER & LAND SURVEYOR: LC ENGINEERING 598 E SANTA CLARA ST. STE 270 SAN JOSE CA 95112 408-806-7187 I NLE@LCENGINEERING.NET • • • • • • HPC/ SCOPE ADDITION EXTERIOR MATERIAL TO BE VERTICAL SIDING, COLOR TO MATCH EXISTING HISTORICAL BUILDING EXISTING CORNER ENTRY TO REMAIN LEFT ENTRY AND STORE FRONT WINDOWS TO BE REHABILITATED TO MATCH 1919-1952 FACADE, SEE A200 ALL OTHER EXTERIOR WINDOWS AND DOORS TO REMAIN, TRIM AND SIDING TO REMAIN, SEE DEMOLITION CALC ON A002 ROOF STRUCTURE TO REMAIN ROOFTOP HOOD/VENT TO BE SCREENED WITH VERTICAL SIDING FINISH 1/8" = 1'-0"1 Site Plan, Proposed Plng BUILDING INFORMATION MODEL SHEET INDEX 0'4' 8' 16'32' General A000. Site Plan, Proposed A001 Site Plan, Existing & Exterior Photos Architectural A200 Elevations, Existing & Proposed A300 Section & Roof Plan & Trash Enclosure A301 Perspective Views & Diagram A302 Perspective & Section Views ATTACHMENT 6 1PARK AVENUECENTER OF STREET 11' - 8" WALL TO P.L 120.96', 0' SIDE YARD SETBACKP.L 120.50', 0' SIDE YARD SETBACKP.L 26.12' P.L 26.08' E MAIN STREET CO OH OHOH OH 4 3 OH N o r t h 8 9 2 7 6 5 10 1 2 3 4 5 6 11 TYP FRONT SETBACK11' - 9" (E)61' - 8" (E) REAR SETBACKATTS LAC E FO ILICENS E D ARCHIT ECTF O RNIAGORD KONW GNO RENEWAL 03/01/2013 4 0 4 53-C 25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025 Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/7/2024 5:43:22 PM 1/8" = 1'-0" A001 Site Plan, Existing & Exterior PhotosSite Plan, Existing & Exterior PhotosBUILDING TO BE RENOVATED PER COMMERCIAL DESIGN GUIDELINES RETAINING WALL METAL BOX TO BE RELOCATED MINI SPLIT CONDENSER, ADJACENT NEIGHBOR'S WATER METER TO BE RESURFACED GAS METER TO BE REPLACED / RELOCATED ELECTRICAL METER TO BE REPLACED / RELOCATED STORM WATER DRAINAGE TO REMAIN TREE TO BE PROTECTED PER CITY CODE PG&E BOX/ ELECTRICAL VAULT TO REMAIN UTILITY POLE TO REMAIN 2 TEATHER TO REMAIN CLEAN OUT RELOCATED, SEE A000 AND CIVIL HYDRANT WATER VALVE LEGEND CO LINE LEGEND SETBACK LINE PROPERTY LINE BUILDING OUTLINE OVERHEAD LINEOH 5 KEYNOTES, SITE PLAN, EXISTING 6 7 4 3 1 8 9 1. 2. 3. 4. 1. 2. 3. 4. 5. 6. 7. TREE PROTECTION NOTES: SEC. 29.10.1005. - PROTECTION OF TREES DURING CONSTRUCTION. (A) PROTECTIVE TREE FENCING SHALL SPECIFY THE FOLLOWING: SIZE AND MATERIALS. SIX (6) FOOT HIGH CHAIN LINK FENCING, MOUNTED ON TWO-INCH DIAMETER GALVANIZED IRON POSTS, SHALL BE DRIVEN INTO THE GROUND TO A DEPTH OF AT LEAST TWO (2) FEET AT NO MORE THAN TEN-FOOT SPACING. FOR PAVING AREA THAT WILL NOT BE DEMOLISHED AND WHEN STIPULATED IN A TREE PRESERVATION PLAN, POSTS MAY BE SUPPORTED BY A CONCRETE BASE. AREA TYPE TO BE FENCED. TYPE I: ENCLOSURE WITH CHAIN LINK FENCING OF EITHER THE ENTIRE DRIPLINE AREA OR AT THE TREE PROTECTION ZONE (TPZ), WHEN SPECIFIED BY A CERTIFIED OR CONSULTING ARBORIST. TYPE II: ENCLOSURE FOR STREET TREES LOCATED IN A PLANTER STRIP: CHAIN LINK FENCE AROUND THE ENTIRE PLANTER STRIP TO THE OUTER BRANCHES. TYPE III: PROTECTION FOR A TREE LOCATED IN A SMALL PLANTER CUTOUT ONLY (SUCH AS DOWNTOWN): ORANGE PLASTIC FENCING SHALL BE WRAPPED AROUND THE TRUNK FROM THE GROUND TO THE FIRST BRANCH WITH TWO-INCH WOODEN BOARDS BOUND SECURELY ON THE OUTSIDE. CAUTION SHALL BE USED TO AVOID DAMAGING ANY BARK OR BRANCHES. DURATION OF TYPE I, II, III FENCING. FENCING SHALL BE ERECTED BEFORE DEMOLITION, GRADING OR CONSTRUCTION PERMITS ARE ISSUED AND REMAIN IN PLACE UNTIL THE WORK IS COMPLETED. CONTRACTOR SHALL FIRST OBTAIN THE APPROVAL OF THE PROJECT ARBORIST ON RECORD PRIOR TO REMOVING A TREE PROTECTION FENCE. WARNING SIGN. EACH TREE FENCE SHALL HAVE PROMINENTLY DISPLAYED AN EIGHT AND ONE-HALF-INCH BY ELEVEN-INCH SIGN STATING: "WARNING—TREE PROTECTION ZONE—THIS FENCE SHALL NOT BE REMOVED AND IS SUBJECT TO PENALTY ACCORDING TO TOWN CODE 29.10.1025." (B) ALL PERSONS, SHALL COMPLY WITH THE FOLLOWING PRECAUTIONS: PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, INSTALL THE FENCE AT THE DRIPLINE, OR TREE PROTECTION ZONE (TPZ) WHEN SPECIFIED IN AN APPROVED ARBORIST REPORT, AROUND ANY TREE AND/OR VEGETATION TO BE RETAINED WHICH COULD BE AFFECTED BY THE CONSTRUCTION AND PROHIBIT ANY STORAGE OF CONSTRUCTION MATERIALS OR OTHER MATERIALS, EQUIPMENT CLEANING, OR PARKING OF VEHICLES WITHIN THE TPZ. THE DRIPLINE SHALL NOT BE ALTERED IN ANY WAY SO AS TO INCREASE THE ENCROACHMENT OF THE CONSTRUCTION. PROHIBIT ALL CONSTRUCTION ACTIVITIES WITHIN THE TPZ, INCLUDING BUT NOT LIMITED TO: EXCAVATION, GRADING, DRAINAGE AND LEVELING WITHIN THE DRIPLINE OF THE TREE UNLESS APPROVED BY THE DIRECTOR. PROHIBIT DISPOSAL OR DEPOSITING OF OIL, GASOLINE, CHEMICALS OR OTHER HARMFUL MATERIALS WITHIN THE DRIPLINE OF OR IN DRAINAGE CHANNELS, SWALES OR AREAS THAT MAY LEAD TO THE DRIPLINE OF A PROTECTED TREE. PROHIBIT THE ATTACHMENT OF WIRES, SIGNS OR ROPES TO ANY PROTECTED TREE. DESIGN UTILITY SERVICES AND IRRIGATION LINES TO BE LOCATED OUTSIDE OF THE DRIPLINE WHEN FEASIBLE. RETAIN THE SERVICES OF A CERTIFIED OR CONSULTING ARBORIST WHO SHALL SERVE AS THE PROJECT ARBORIST FOR PERIODIC MONITORING OF THE PROJECT SITE AND THE HEALTH OF THOSE TREES TO BE PRESERVED. THE PROJECT ARBORIST SHALL BE PRESENT WHENEVER ACTIVITIES OCCUR WHICH MAY POSE A POTENTIAL THREAT TO THE HEALTH OF THE TREES TO BE PRESERVED AND SHALL DOCUMENT ALL SITE VISITS. THE DIRECTOR AND PROJECT ARBORIST SHALL BE NOTIFIED OF ANY DAMAGE THAT OCCURS TO A PROTECTED TREE DURING CONSTRUCTION SO THAT PROPER TREATMENT MAY BE ADMINISTERED. ( ORD. NO. 2240, § I(EXH. B), 6-2-15 ) 10 1. 2. NOTES GENERAL CONTRACTOR TO VERIFY EXISTING SITE CONDITIONS, STRUCTURES, DIMENSIONS ALL ELEMENTS IN BLUE ARE TO BE DEMOLISHED 0'4' 8' 16'32' 1/8" = 1'-0"1Site Plan, Existing 1 2 3 4 5 6 11 PUBLIC WORKS & PLAN SITE NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL AND INSURING AREA ADJACENT TO WORK IS LEFT IN A CLEAN CONDITION. UTILIZE BEST MANAGEMENT PRACTICES (BMP'S), AS REQUIRED BY THE STATE WATER RESOURCES BOARD, FOR ANY ACTIVITY, WHICH DISTURBS SOIL. CONTRACTOR IS RESPONSIBLE FOR ALL TEST, INSPECTIONS AND PROCEDURAL REQUIREMENTS PER CITY OF LOS GATOS. OPERABLE SMOKE DETECTORS MUST BE IN PLACE PRIOR TO RE-OCCUPY DWELLINGS PLUMBING & ELECTRICAL SURVEY REQUIRED FOR METER RELEASE. ADDITIONS, ALTERATIONS OR REPAIRS SHALL CONFORM TO ANY BUILDING OR STRUCTURE WITHOUT REQUIRING THE EXISTING BUILDING OR STRUCTURE TO COMPLY WITH ALL THE REQUIREMENTS OF THE UBC, PROVIDED THE ADDITION ALTERATION OR REPAIR CONFORMS TO THAT REQUIRED FOR NE WBUILDING OR STRUCTURE PER UBC SECTION 3403.2. CONTRACTOR TO VERIFY SIZE & LOCATION OF ALL UTILITY CONNECTIONS. CONTRACTOR TO PROVIDE ALL NEW UTILITY CONNECTIONS AND/ OR UPGRADE EXISTING AS REQUIRED. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND APPROVALS AS REQUIRED BY GOVERNING AGENCIES. CONTRACTOR SHALL OBTAIN ALL NECESSARY DEMOLITION PERMITS AND APPROVALS INCLUDING ASBESTOS ABATEMENT AS PART OF THE BASE BID PER CGBSC 301.1.1 - RESIDENTIAL BUILDINGS UNDERGOING PERMITTED ALTERATIONS, ADDITIONS OR IMPROVEMENTS SHALL REPLACE NONCOMPLIANT PLUMBING FIXTURES WITH WATER-CONSERVING PLUMBING FIXTURES. PLUMBING FIXTURES REPLACEMENT IS REQUIRED PRIOR TO ISSUNACE OF A CERTIFICATE OF FINAL COMPLETION, CERTIFICATE OF OCCUPANCY OR FINAL PERMIT APPROVAL BY THE LOCAL BUILDING DEPARTMENT. PER CGBSC 301.1.1 - WHERE ADDITION OR ALTERATION INCREASED THE BUILDING'S CONDITIONED AREA, VOLUME, OR SIZE, THE REQUIREMENTS OF CALGreen CHAPTER 5 SHALL APPLY ONLY TO AND WITHIN THE SPECIFIC AREA OF THE ADDITION OR ALTERATION. Revision Schedule Number Description Date 2 Planning 2023.03.17 6 Building Date 6 APPLICABLE CODE 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 2022 CALIFORNIA BUILDING CODES PART 1, 6, 10 & 11 2022 CALIFORNIA BUILDING CODES PART 2, 2.5, 3 - 5, 8 - 9, 12 2022 CALIFORNIA RESIDENTIAL CODE PART 2.5 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING CODES ALL OTHER STATE AND LOCAL LAWS, ORDINANCES AND REGULATIONS TOWN OF LOS GATOS MUNICIPAL CODE 2022 CALIFORNIA HISTORIC BUILDING CODE SANTA CLARA COUNTY FIRE DEPARTMENT (SCCFD) SPECIFICATIONS 1st T.O.P8' - 9 5/16" 2nd F.F9' - 10 5/16" 2nd T.O.P 14' - 11" T.O.R. 21' - 10 11/16" Grade/1st F.F. 0' - 0" (D) (E) (R)21'-11"8'-9" 1'-1" 5'-1" 7'-0" (E)(E) (E) 1st T.O.P8' - 9 5/16" 2nd F.F 9' - 10 5/16" 2nd T.O.P 14' - 11" T.O.R.21' - 10 11/16" 3 Grade/1st F.F. 0' - 0"21'-11"8'-9" 1'-1" 5'-1" 7'-0" 4 3 (P)(E) (P) (E)(E) (E) (E) DOOR TO BE NON- FUNCTIONING A103 1 (P) 6 MAKE-UP AIR UNIT 1 3 LINE OF S I G H T 1st T.O.P8' - 9 5/16" 2nd F.F9' - 10 5/16" 2nd T.O.P 14' - 11" T.O.R. 21' - 10 11/16" (D) (D)(D) Grade/1st F.F.0' - 0"21'-11"7'-0"5'-1"1'-1"8'-9"(R) STORAGE DEMOLITION 1st T.O.P8' - 9 5/16" 2nd F.F 9' - 10 5/16" 2nd T.O.P14' - 11" T.O.R.21' - 10 11/16" 3 1 Grade/1st F.F. 0' - 0"7'-0"5'-1"1'-1"8'-9"(P)4'-1"21'-11"(P) (E) 4 5 3'-6"STAMPED CONCRETE DECK TRELLIS, WOOD GUARDRAIL 2 MAKE-UP AIR UNIT1 3 LINE OF SI G H T 3'-1"1st T.O.P8' - 9 5/16" 2nd F.F9' - 10 5/16" 2nd T.O.P 14' - 11" T.O.R. 21' - 10 11/16" Grade/1st F.F. 0' - 0"21'-11"7'-0"5'-1"1'-1"8'-9"(E)(E)(E) DEMOLISHED SHED 1st T.O.P 8' - 9 5/16" 2nd F.F 9' - 10 5/16" 2nd T.O.P 14' - 11" T.O.R.21' - 10 11/16" 2 Grade/1st F.F. 0' - 0"1 21'-11"7'-0"5'-1"1'-1"8'-9"(E)(E)(E) 5 LANDSCAPING,SEE/8A003 TRELLIS/WOOD W/ STRING LIGHTS MECHANICAL UNITSTRASH ENCLOSURE HOOD/VENT MAKE-UP AIR UNIT 2'-5"3'-11"SCREEN 1 3 LINE OF S I G H T 1 3 LINE OF SI G H T 6'-4"3'-1"1st T.O.P8' - 9 5/16" 2nd F.F9' - 10 5/16" 2nd T.O.P 14' - 11" T.O.R. 21' - 10 11/16" (E) (D) Grade/1st F.F.0' - 0"21'-11"7'-0"5'-1"1'-1"8'-9"(E) (E)(E) (E)(E)(E) STORAGE DEMOLITION 1st T.O.P8' - 9 5/16" 2nd F.F 9' - 10 5/16" 2nd T.O.P14' - 11" T.O.R.21' - 10 11/16" (P) 1 Grade/1st F.F. 0' - 0" 2 7'-0"5'-1"1'-1"8'-9"(P)21'-11"3 4 5 TRASH AREA SCREENED BY CMU WALL AND PLANTING TRELLIS, WOOD W/ STRING LIGHTS (E) CORNER FACADE TO REMAIN (E) DOOR TO BE NON-FUNCTIONING (E) (E) (E) (E) (E)(E)(E) 6 MAKE-UP AIR UNITSCREEN, VERTICAL SIDING3'-1"6'-4"4'-1"ELEVATION KEYNOTES/ MATERIAL 1 2 3 (E) (D) EXISTING TO BE DEMOLISHED ELEVATION LEGEND 4 EXTERIOR VERTICAL SIDING/ JAMES HARDIE COLOR TO MATCH EXISTING ROOFING MATERIAL CLASS A COMPOSITION SHINGLES TO MATCH EXISTING WINDOW GLASS PANES TO BE REPLACED, TRIM AND FRAME TO REMAIN FIXTURES TO MINIMIZE GLARE AND LIGHT SPILL ONTO AREAS OFF OF THE BUILDING SITE. EXTERIOR LIGHTING TO BE DOWNLIT 5 WOOD FENCE 1. 2. NOTE CONTRACTOR TO VERIFY DIMENSIONS, EXISTING CONDITIONS, STRUCTURES, UTILITIES ON SITE. OWNER ALLOWED TO CHOOSE ALTERNATIVE COMPLIANT PRODUCT. PROPOSED TO BE REPLACED (P) (R) 6 ADDRESS IDENTIFICATION, CONTRAST WITH BACKGROUND, MIN 4 INCH HIGH, MIN STROKE 0.5 INCH, PER CBC SEC 505.1 1949-1952 1910 ATTS LAC E FO ILICENS E D ARCHIT ECTF O RNIAGORD KONW GNO RENEWAL 03/01/2013 4 0 4 53-C 25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025 Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/7/2024 5:44:32 PM As indicated A200 Elevations, Existing & ProposedElevations, Existing & Proposed 1/8" = 1'-0"1Elevation, Front, Existing 1/8" = 1'-0"3Elevation, Front, Proposed 1/8" = 1'-0"5Elevation, Rear, Existing 1/8" = 1'-0"7Elevation, Rear, Proposed 0'4' 8' 16'32' PHOTO REFERENCE 0'4' 8' 16'32' 1/8" = 1'-0"2Elevation, Left, Existing 1/8" = 1'-0"4Elevation, Left, Proposed 1/8" = 1'-0"6Elevation, Right, Existing 1/8" = 1'-0"8Elevation, Right, Proposed 0'4' 8' 16'32' 0'4' 8' 16'32' 0'4' 8' 16'32' 0'4' 8' 16'32' 0'4' 8' 16'32' 0'4' 8' 16'32' Revision Schedule Number Description Date 1 Planning 2022.10.19 2 Planning 2023.03.17 6 Building Date 6 1st T.O.P8' - 9 5/16" 2nd F.F 9' - 10 5/16" 2nd T.O.P14' - 11" T.O.R.21' - 10 11/16" Grade/1st F.F. 0' - 0"6"STAIRWELL KITCHENDINING/BAR BAR 21'-11"7'-0"5'-1"1'-1"8'-9"TYP7" RISECRAWL SPACE 1 2 3 6 DINING HOOD VENT/ DISCHARGE SCREEN/ VERTICAL SIDING 4'-1"3'-0"1st T.O.P8' - 9 5/16" 2nd F.F9' - 10 5/16" 2nd T.O.P 14' - 11" T.O.R. 21' - 10 11/16" Grade/1st F.F.0' - 0"21'-11"7'-0"5'-1"1'-1"8'-9"2 1 CRAWL SPACE 4 7'-6"DINING 3 1/2" 12" 3 1/2" 12"8'-9"6 HALLWAY ALL-GENDER RESTRM 9 A300 10 A300 3 1/2" / 12"5 1/2" / 12"RIDGE RIDGED.S.D.S. D.S.D.S.D.S.10'-9"5'-0"10'-3"3 1/2" / 12"5 1/2" / 12"22'-10"11'-1"17'-0" 8'-2"14'-6"11'-5"14'-2" R EEEE5 1/2" / 12"5 1/2" / 12"13'-4"12'-9"26'-0"50'-11" (E) PARAPET ROOF TO REMAIN 11 A300 MUA 13 A300 HOOD EXHAUST/ DISCHARGE10'-0" MINSCREEN 14'-0"10'-0" MIN1'-6"2'-0"1'-6"6'-10"6'-4"1'-2"5 A302 37 10'-9"7'-8" 2" / 12" 1 7 3 7'-8" 29"3'-2"6'-0"2" 12" 1 2 3 7 6'-0"1'-11" 2'-1" 1'-2"8'-5"1'-2" 10'-9" 1'-2" 1 7 3 10'-9"2'-0"1'-11"6'-0"A300 6 A3004 A3005 7 A300 5412 A300 8 2% SLOPE 9 6 8 D10 D148"5'-0" 1'-2"8'-5"1'-2"2'-6"5'-2" 7'-8"10'-9"1'-0" 1 7 2 5 4 3 6 7'-8"3'-11"6'-0"2" 12"9"3'-2"6'-0"1 7 3 2 7'-8" 2" 12" UTILITY 5 STAIRWELL8'-0" 2'-11"8'-9"4'-8"10'-9"20'-9"7'-11"3'-6"FIRE RISER HOURLY RATING: 1-HOUR FIRE TEST REFERENCE: UL L501, cUL L501, GA FC 5420 5/8” (15.9 MM) TOUGHROCK® FIREGUARD X® PRODUCTS APPLIED PERPENDICULAR TO 2” X 10” WOOD JOISTS 16” (406 MM) O.C. WITH 1-7/8” (48 MM) 6D NAILS 6” (152 MM) O.C. WOOD JOISTS SUPPORTING 1” (25.4 MM) NOMINAL WOOD SUB AND 1” (25.4 MM) NOMINAL FINISH FLOOR, OR 19/32” (15.1 MM) PLYWOOD FINISHED FLOOR WITH LONG EDGES T&G AND 15/32” (11.9 MM) INTERIOR PLYWOOD WITH XTERIOR GLUE SUBFLOOR PERPENDICULAR TO JOISTS WITH JOINTS STAGGERED. APPROVED FOR ASSEMBLY: DENSARMOR PLUS® FIREGUARD C® PRODUCTS DENSARMOR PLUS® FIREGUARD® PRODUCTS DENSELEMENT® BARRIER SHEATHING DENSGLASS® FIREGUARD® SHEATHING DENSSHIELD® FIREGUARD® TILE BACKER TOUGHROCK® FIREGUARD C® PRODUCTS TOUGHROCK® FIREGUARD X® MOLD-GUARD® PRODUCTS TOUGHROCK® FIREGUARD X® PRODUCTS TOUGHROCK® LITE-WEIGHT FIRE-RATED PRODUCTS 1 (E) ROOF PARAPET TO REMAIN (E) WALL, (P) INSULATION (P) HANDRAIL 2 SECTION KEY NOTES 3 4 5 (E) DORMER/ ROOF, NEW INSULATION 1-HOUR RATED FLOOR/CEILING ASSEMBLY, SEE MAKE-UP AIR UNIT, SEE MEP PLANS /12 A300 6 1st FF0' - 0" 2nd F.F9' - 10 5/16" 2nd T.O.P14' - 11" T.O.R.21' - 10 11/16" Grade/1st F.F.0' - 0" PLYWOOD, MIN 1.25" WITH ROOF PAN 1/2" BOLT DOWN FAN LINE O F S I G H T 21'-11"3'-0"8'-9"SCREEN5'-8"5'-6"1 3 5'-6"D.S. R E BUILDING FOOTPRINT DOWNSPOUT, TO CONNECT TO STORM WATER PIPE RIDGE VENT EAVE VENT ATTIC AREA ROOFTOP VENT HOOD MAKEUP AIR UNIT LEGEND MUA ATTS LAC E FO ILICENS E D ARCHIT ECTF O RNIAGORD KONW GNO RENEWAL 03/01/2013 4 0 4 53-C 25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025 Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/7/2024 5:44:47 PM As indicated A300 Section & Roof Plan & Trash EnclosureSection & Roof Plan & Trash Enclosure 1/8" = 1'-0"9 Section 1, Proposed 0'4' 8' 16'32' 1/8" = 1'-0"10 Section 2, Proposed 0'4' 8' 16'32' 0'2' 4'8'16' • STAIRCASE ATTIC VENT CALCS: REQUIRED VENTILATION 64 SF / 150 = 0.43 SF (61.44 SI) IDEAL RATIO (UPPER VENT : LOWER VENT) = 50% : 50% = 30.72 SI : 30.72 SI RIDGE VENT: (N.F.A. = 18 SI PER LINEAR FT) PROVIDED LENGTH = 3 FT 3 x 18 = 48 SI EAVE VENT:(N.F.A. 7.06 SI PER VENT) PROVIDED HOLES = 4 7.06 x 4 = 28.24 SI TOTAL = 48 + 28.24 = 76.24 SI> 61.44 SI, OKAY 1/4" = 1'-0"1Roof Plan, Proposed NOTES: **ALL ROOF SHEATHING TO USE FIRE RETARDANT TREATED ROOF SHEATHING OR APPROVED EQUIVALENT **ALL ROOFING FINISH MATERIAL TO BE CLASS A AND SHALL MATCH EXISTING ROOF Revision Schedule Number Description Date 2 Planning 2023.03.17 6 Building Date 6 1/4" = 1'-0"2Trash Enclosure Roof Plan 1/4" = 1'-0"6Trash Enclosure, Left Side Elevation 1/4" = 1'-0"5Trash Enclosure, Front Elevation 1/4" = 1'-0"4Trash Enclosure, Rear Elevation 1CMU WALL 2MTL FABRICATED DOOR POWDER COATED TRASH ENCLOSURE KEY NOTES 3GALV. STANDING SEAM MTL SHED ROOF, GALV. 4TRASH BIN 5TRASH BIN BUMPER, CONCRETE 6 1/4" = 1'-0"3Trash Enclosure Floor Plan 1/4" = 1'-0"7Trash Enclosure, Section 7FASCIA BOARD 1/4" = 1'-0"8Trash Enclosure, Right Side Elevation 8FLOOR DRAIN, SEE CIVIL AND PLUMBING SHEETS 9J-HOOKS FOR SECURING THE DOOR FOR SERVICING 1/8" = 1'-0"11 Section, Stairwell 1" = 1'-0"12 1-Hour Fire Rated Ceiling/ Floor PERMEABLE PAVERS 1/8" = 1'-0"13 Section, Hood 3Section View, Front 4Section View, Rear ATTS LAC E FO ILICENS E D ARCHIT ECTF O RNIAGORD KONW GNO RENEWAL 03/01/2013 4 0 4 53-C 25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025 Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/7/2024 5:45:49 PM A301 Perspective Views & DiagramPerspective Views & DiagramTRASH AREA SCREENED BY 6'-0" WOOD FENCE AND LANDSCAPING LANDSCAPING, SEE A003 OUTDOOR DECK/ DINING AREA TRELLIS, STRING LIGHTING WITH WOOD FENCE/ SCREENING, 3'-6" ADDITION/ STAIRCASE ACCESSIBLE RAMP WITH HANDRAILS PERMEABLE PAVERS DRY STACKED RETAINING WALL WOOD FENCE 3'-6", ENCLOSING OUTDOOR DINING AREA (E) POWER POLE TO REMAIN (E) CORNER FACADE TO REMAIN (E) DOOR TO BE NON-FUNCTIONING (P) ENTRY DOOR TO BE REHABILITATED TO MATCH 1919-1952 PHOTO, SEE A200 (E) HORIZONTAL SIDING TO REMAIN CONCRETE RETAINING WALL (E) WINDOWS AND TRIM TO REMAIN, GLASS PANE TO BE REPLACED (E) ROOF STRUCTURE TO REMAIN VERTICAL SIDING, COLOR TO MATCH EXISTING Revision Schedule Number Description Date ROOFTOP VENT WITH SCREEN, VERTICAL SIDING ROOFTOP VENT WITH SCREEN, VERTICAL SIDING FAN LINE O F S I G H T SCREEN5'-8"13 5'-6"21'-11"3'-1"1st T.O.P 8' - 9 5/16" 2nd F.F9' - 10 5/16" 2nd T.O.P14' - 11" T.O.R. 21' - 10 11/16" Grade/1st F.F.0' - 0" (P)7'-0"5'-1"1'-1"8'-9"(P)21'-11"(E)(E)(E) (E) (E)(E)(E) SCREEN, VERTICAL SIDING3'-1"6'-4"4'-1"5'-8"LINE OF S I G H T LI N E O F S I G H T ATTS LAC E FO ILICENS E D ARCHIT ECTF O RNIAGORD KONW GNO RENEWAL 03/01/2013 4 0 4 53-C 25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025 Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/7/2024 5:46:36 PM 1" = 10'-0" A302 Perspective & Section ViewsPerspective & Section ViewsRevision Schedule Number Description Date 1 Planning 2022.10.19 2 Planning 2023.03.17 1Street View, Rear Corner 2Street View, Corner 3 Street View, Front 4 Street View, Rear Patio 1" = 10'-0"5Section, Hood.. 1" = 10'-0"6Elevation, Right, Proposed. HOOD VENT IS NOT VISIBLE FROM THE REAR PATIO HOOD VENT/ VERTICAL SIDING SCREEN HOOD VENT/ VERTICAL SIDING SCREEN HOOD VENT IS NOT VISIBLE FROM FRONT STREET VIEW