Attachment 6 - Development PlansSITE PLAN, PROPOSED, KEYNOTES
1 PROPOSED LANDSCAPING
RETAINING WALL, CONCRETE
ELECTRICAL METER/ PANEL
GAS METER
TRASH ENCLOSURE, CMU, 2Y GARBAGE, 1.5Y RECYCLE & COMPOST, SEPARATE PERMIT
WITH FIRE SPRINKLER
EXTERIOR MECHANICAL UNITS
DRY STACK RETAINING WALL
KNOX BOX
OUTDOOR DECK/DINING WITH TRELLIS AND STRING LIGHTS
(E) STREET TREE, CALIFORNIA BAY, DIAMETER 18"
WITH PROTECTIVE FENCING, SEE TREE PROTECTION AND FENCING NOTES,
ROOFTOP VENT HOOD
MAKE-UP AIR UNIT, SEE MEP PLANS
FIRE DEPARTMENT CONNECTION
SCREEN, VERTICAL SIDING AND COLOR TO MATCH ADDITION
(P) WATER METER
2
3
4
5
7
LEGEND
CO
POWER POLE TETHER
CLEAN OUT
HYDRANT
SETBACK LINE
PROPERTY LINE
BUILDING FOOTPRINT
8
SITE PLAN NOTES:
1.
2.
3.
IF ANY EXCAVATION EXCEEDS 5-FEET IN
DEPTH OR REMOVES LATERAL
SUPPORT FROM AN EXISTING BUILDING,
AN ADJACENT PROPERTY, OR THE
PUBLIC RIGHT OF WAY, THE PROJECT
WILL HALTED UNTIL SHORING PLANS
AND CALCULATIONS PREPARED BY A CA
LICENSED ENGINEER ARE PROVIDED TO
THE TOWN OF LOS GATOS BUILDING
DIVISION FOR REVIEW AND APPROVAL.
PROJECT MAY RESUME CONSTRUCTION
ONCE SHORING PLANS HAVE BEEN
APPROVED FOR CONSTRUCTION AND
INSTALLED ACCORDING TO APPROVED
PLANS.
CONTRACTOR SHALL FIELD VERIFY
LOCATIONS OF UTILITIES, SITE
CONDITIONS, DIMENSIONS,
STRUCTURES PRIOR TO START OF
WORK. IN EVENT OF ANY
DISCREPANCIES OR POTENTIAL
CONFLICTS, NOTIFY THE ARCHITECT IN
WRITING PRIOR TO STARTING EACH
PORTION OF THE WORK.
ESTIMATED CUT 0 CY/ FILL 29 CY
9
10
RIGHT-OF-WAY DEDICATION (SEE CIVIL)
(P) TRUNCATED DOME
(P) ACCESSIBLE PATH OF TRAVEL
11
12
1.
2.
3.
4.
NOTES
DOCUMENTATION SHALL BE PROVIDED, PRIOR TO FIRST INSPECTION, CONFIRMING
COMPLIANCE TO THE WASTE MANAGEMENT PLAN PROVIDED TO THE JURISDICTION.
CGBSC SECTION 5.408.1.4
ALL ADHESIVES, SEALANTS, CAULKS, PAINTS, COATINGS, AND AEROSOL PAINT CONTAINERS
MUST REMAIN ON THE SITE FOR FIELD VERIFICATION BY THE BUILDING INSPECTOR. CGBSC
SECTION 5.504.4.3.2
PRIOR TO FINAL INSPECTION, A LETTER SIGNED BY THE GENERAL CONTRACTOR OR THE
OWNER/BUILDER (FOR ANY OWNER/BUILDER PROJECTS) MUST BE PROVIDED TO THE TOWN
OF LOS GATOS BUILDING OFFICIAL CERTIFYING THAT ALL ADHESIVES, SEALANTS, CAULKS,
PAINTS, COATINGS, AEROSOL PAINTS, AEROSOL COATINGS, CARPET SYSTEMS (INCLUDING
CARPETING, CUSHION AND ADHESIVE), RESILIENT FLOORING SYSTEMS, AND COMPOSITE
WOOD PRODUCTS INSTALLED ON THIS PROJECT ARE WITHIN THE EMISSION LIMITS
SPECIFIED IN CGBSC SECTION 5.504.
HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT SHALL NOT CONTAIN CFCS OR
HALONS. CGBSC SECTION 5.508.1
13
14
/4 A001.1
W
15PARK AVENUEE MAIN STREET
CO
N
o
r
t
h11'-6"R/W DEDICATION
262 SF57'-4" REAR SETBACK3
2
4
0' - 0"
-1' - 6"
5
7 (E) O.H. TEAT
HE
R
P.L 26.12'P.L 120.96' 0' SETBACKP.L 120.50' 0' SETBACKP.L 26.08'10'-0"TENANT IMPROVEMENT
2,153 SF
9
27'-10"ADDITION 128 SF
11
1
3'-1"
-2' - 6"
8
10
1" / 12"1" / 12"FRONT SB1'-6"10'-0"10'-0"
2'-6"PAVERS8'-4"12
6'-3"
13
3'-9"
10'-0" MIN
14
15W
3'-0"MUA
10'-0" MIN
PROJECT
LOCATION
PARK AVE
W
M
A
I
N
S
T
S SANTA CRUZ AVEBR
O
A
D
W
A
YN SANTA CRUZ AVEW
M
A
I
N
S
T
UNIVERSITY AVELUNDY LNMAPLE PLCOLLEGE AVEPAGEANT WAYE MAIN STHWY 17HWY 17ATTS
LAC
E
FO ILICENS E D ARCHIT
ECTF O RNIAGORD KONW
GNO
RENEWAL 03/01/2013
4 0 4 53-C
25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025
Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/17/2024 10:36:09 AM
As indicated
A000.
Site Plan,
ProposedSite Plan, ProposedRevision Schedule
Number Description Date
1 Planning 2022.10.19
2 Planning 2023.03.17
3 Planning 2023.05.02
6 Building Date 6
7 Plng Historical 2024.06.07
SCOPE OF WORK
•
•
•
TENANT IMPROVEMENT 2,153 SF
1ST FLOOR1,073 SF
2ND FLOOR 1,080 SF
ADDITION128 SF
SITE ADJUSTMENTS
OUTDOOR DECK 361SF, TRELLIS AND STRING LIGHTS
LANDSCAPING PER COMMERCIAL DESIGN GUIDELINES
TRASH ENCLOSURE
PROJECT INFORMATION
25 WEST MAIN ST.
C A L I F O R N I AL O S G A T O S
VICINITY MAP
PROJECT LOCATION:
APN:
PROJECT JURISDICTION:
ZONING:
GENERAL PLAN USE:
(E) / (P) OCCUPANCY:
(E) USE / (P) USE:
YEAR BUILT/OCCUPIED:
GROSS LOT SIZE:
NET LOT SIZE:
AVG. SLOPE OF LOT:
RIGHT-OF-WAY DEDICATION:
(E)GROSS FLOOR AREA:
1ST LVL:
2ND LVL:
(P) GROSS FLOOR AREA:
1ST LVL:
1ST LVL ADDITION:
2ND LVL:
FAR:
ALLOWED:
EXISTING:
PROPOSED:
REQUIRED PARKING:
RESTAURANT 2,281 SF(1/300 SF)
PROPOSED PARKING
PARKING DISTRICT SPACES
CONSTRUCTION TYPE
FIRE SPRINKLERS:
SET BACKS
FRONT:
SIDE:
REAR:
STREET SIDE:
MAX. HEIGHT:
(E) & (P) HEIGHT:
25 W MAIN STREET, LOS GATOS, CA 95030
529 - 01 - 017
LOS GATOS
C-2: LHP CENTRAL BUSINESS DISTRICT (LOS GATOS HISTORICAL COM. DISTRICT)
CENTRAL BUSINESS DISTRICT
M / A-2
RETAIL / RESTAURANT
1901
3,133 SF
2,871 SF
6%
262 SF
2,170 SF
1,090 SF
1,080 SF
2,281 SF
1,073 SF
128 SF
1,080 SF
FLOOR AREA / LOT SIZE
60 % = 1,880 SF / 3,133 SF
69 % = 2,170 SF/ 3,133 SF
79 % = 2,281 SF/ 2,871 SF
8
7 (1 SPACE REQUEST FOR PARKING VARIANCE)
V-B
YES
(REQUIRED / EXISTING / PROPOSED)
10'-0" / 11'-9" / 1'-6"
0'-0" / 0'-0" / 0'-0"
0'-0" / 61'-8" / 57'-4"
10'-0" / 0'-0" / 0'-0"
45'-0"
21'-11"
THIS PROJECT PROPOSES A TENANT IMPROVEMENT FOR A RESTAURANT (2,153 SF) AND ADDITION (128 SF) TO THE HISTORIC
TWO-STORY BUILDING. SCOPE INCLUDES A NEW CIRCULATION SPACE WITH A STAIRWAY AND ACCESSIBLE SITE UPGRADES. THE
OCCUPANCY/USE TO CHANGE FROM (M) MERCANTILE, TO (A-2) ASSEMBLY.
OWNER:
PROJECT DIRECTORY
REVEAL 004 LLC
675 NORTH FIRST STREET, SUITE 550 SAN JOSE CA 95112
408-314-0077 I INFO@REVEALCORP.COM
ARCHITECT:GKW ARCHITECTS, INC.
710 E. MCGLINCY LANE SUITE 109 CAMPBELL, CA 95008
408-315-2125 I GORDONKWONG@GKWARCHITECTS.COM
CIVIL ENGINEER &
LAND SURVEYOR:
LC ENGINEERING
598 E SANTA CLARA ST. STE 270 SAN JOSE CA 95112
408-806-7187 I NLE@LCENGINEERING.NET
•
•
•
•
•
•
HPC/ SCOPE
ADDITION EXTERIOR MATERIAL TO BE VERTICAL SIDING, COLOR TO
MATCH EXISTING HISTORICAL BUILDING
EXISTING CORNER ENTRY TO REMAIN
LEFT ENTRY AND STORE FRONT WINDOWS TO BE REHABILITATED TO
MATCH 1919-1952 FACADE, SEE A200
ALL OTHER EXTERIOR WINDOWS AND DOORS TO REMAIN, TRIM AND
SIDING TO REMAIN, SEE DEMOLITION CALC ON A002
ROOF STRUCTURE TO REMAIN
ROOFTOP HOOD/VENT TO BE SCREENED WITH VERTICAL SIDING
FINISH
1/8" = 1'-0"1 Site Plan, Proposed Plng
BUILDING INFORMATION MODEL
SHEET INDEX
0'4' 8' 16'32'
General
A000. Site Plan, Proposed
A001 Site Plan, Existing & Exterior Photos
Architectural
A200 Elevations, Existing & Proposed
A300 Section & Roof Plan & Trash Enclosure
A301 Perspective Views & Diagram
A302 Perspective & Section Views
ATTACHMENT 6
1PARK AVENUECENTER OF STREET
11' - 8" WALL TO P.L 120.96', 0' SIDE YARD SETBACKP.L 120.50', 0' SIDE YARD SETBACKP.L 26.12'
P.L 26.08'
E MAIN STREET
CO
OH
OHOH
OH
4
3
OH
N
o
r
t
h
8
9
2
7
6
5
10
1
2
3
4
5
6
11
TYP
FRONT SETBACK11' - 9" (E)61' - 8" (E) REAR SETBACKATTS
LAC
E
FO ILICENS E D ARCHIT
ECTF O RNIAGORD KONW
GNO
RENEWAL 03/01/2013
4 0 4 53-C
25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025
Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/7/2024 5:43:22 PM
1/8" = 1'-0"
A001
Site Plan, Existing
& Exterior PhotosSite Plan, Existing & Exterior PhotosBUILDING TO BE RENOVATED PER COMMERCIAL DESIGN GUIDELINES
RETAINING WALL
METAL BOX TO BE RELOCATED
MINI SPLIT CONDENSER, ADJACENT NEIGHBOR'S
WATER METER TO BE RESURFACED
GAS METER TO BE REPLACED / RELOCATED
ELECTRICAL METER TO BE REPLACED / RELOCATED
STORM WATER DRAINAGE TO REMAIN
TREE TO BE PROTECTED PER CITY CODE
PG&E BOX/ ELECTRICAL VAULT TO REMAIN
UTILITY POLE TO REMAIN
2
TEATHER TO REMAIN
CLEAN OUT RELOCATED, SEE A000 AND CIVIL
HYDRANT
WATER VALVE
LEGEND
CO
LINE LEGEND
SETBACK LINE
PROPERTY LINE
BUILDING OUTLINE
OVERHEAD LINEOH
5
KEYNOTES, SITE PLAN, EXISTING
6
7
4
3
1
8
9
1.
2.
3.
4.
1.
2.
3.
4.
5.
6.
7.
TREE PROTECTION NOTES:
SEC. 29.10.1005. - PROTECTION OF TREES DURING CONSTRUCTION.
(A) PROTECTIVE TREE FENCING SHALL SPECIFY THE FOLLOWING:
SIZE AND MATERIALS. SIX (6) FOOT HIGH CHAIN LINK FENCING, MOUNTED ON TWO-INCH DIAMETER GALVANIZED IRON
POSTS, SHALL BE DRIVEN INTO THE GROUND TO A DEPTH OF AT LEAST TWO (2) FEET AT NO MORE THAN TEN-FOOT
SPACING. FOR PAVING AREA THAT WILL NOT BE DEMOLISHED AND WHEN STIPULATED IN A TREE PRESERVATION
PLAN, POSTS MAY BE SUPPORTED BY A CONCRETE BASE.
AREA TYPE TO BE FENCED. TYPE I: ENCLOSURE WITH CHAIN LINK FENCING OF EITHER THE ENTIRE DRIPLINE AREA
OR AT THE TREE PROTECTION ZONE (TPZ), WHEN SPECIFIED BY A CERTIFIED OR CONSULTING ARBORIST. TYPE II:
ENCLOSURE FOR STREET TREES LOCATED IN A PLANTER STRIP: CHAIN LINK FENCE AROUND THE ENTIRE PLANTER
STRIP TO THE OUTER BRANCHES. TYPE III: PROTECTION FOR A TREE LOCATED IN A SMALL PLANTER CUTOUT ONLY
(SUCH AS DOWNTOWN): ORANGE PLASTIC FENCING SHALL BE WRAPPED AROUND THE TRUNK FROM THE GROUND TO
THE FIRST BRANCH WITH TWO-INCH WOODEN BOARDS BOUND SECURELY ON THE OUTSIDE. CAUTION SHALL BE
USED TO AVOID DAMAGING ANY BARK OR BRANCHES.
DURATION OF TYPE I, II, III FENCING. FENCING SHALL BE ERECTED BEFORE DEMOLITION, GRADING OR
CONSTRUCTION PERMITS ARE ISSUED AND REMAIN IN PLACE UNTIL THE WORK IS COMPLETED. CONTRACTOR SHALL
FIRST OBTAIN THE APPROVAL OF THE PROJECT ARBORIST ON RECORD PRIOR TO REMOVING A TREE PROTECTION
FENCE.
WARNING SIGN. EACH TREE FENCE SHALL HAVE PROMINENTLY DISPLAYED AN EIGHT AND ONE-HALF-INCH BY
ELEVEN-INCH SIGN STATING: "WARNING—TREE PROTECTION ZONE—THIS FENCE SHALL NOT BE REMOVED AND IS
SUBJECT TO PENALTY ACCORDING TO TOWN CODE 29.10.1025."
(B) ALL PERSONS, SHALL COMPLY WITH THE FOLLOWING PRECAUTIONS:
PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, INSTALL THE FENCE AT THE DRIPLINE, OR TREE PROTECTION
ZONE (TPZ) WHEN SPECIFIED IN AN APPROVED ARBORIST REPORT, AROUND ANY TREE AND/OR VEGETATION TO BE
RETAINED WHICH COULD BE AFFECTED BY THE CONSTRUCTION AND PROHIBIT ANY STORAGE OF CONSTRUCTION
MATERIALS OR OTHER MATERIALS, EQUIPMENT CLEANING, OR PARKING OF VEHICLES WITHIN THE TPZ. THE DRIPLINE
SHALL NOT BE ALTERED IN ANY WAY SO AS TO INCREASE THE ENCROACHMENT OF THE CONSTRUCTION.
PROHIBIT ALL CONSTRUCTION ACTIVITIES WITHIN THE TPZ, INCLUDING BUT NOT LIMITED TO: EXCAVATION, GRADING,
DRAINAGE AND LEVELING WITHIN THE DRIPLINE OF THE TREE UNLESS APPROVED BY THE DIRECTOR.
PROHIBIT DISPOSAL OR DEPOSITING OF OIL, GASOLINE, CHEMICALS OR OTHER HARMFUL MATERIALS WITHIN THE
DRIPLINE OF OR IN DRAINAGE CHANNELS, SWALES OR AREAS THAT MAY LEAD TO THE DRIPLINE OF A PROTECTED
TREE.
PROHIBIT THE ATTACHMENT OF WIRES, SIGNS OR ROPES TO ANY PROTECTED TREE.
DESIGN UTILITY SERVICES AND IRRIGATION LINES TO BE LOCATED OUTSIDE OF THE DRIPLINE WHEN FEASIBLE.
RETAIN THE SERVICES OF A CERTIFIED OR CONSULTING ARBORIST WHO SHALL SERVE AS THE PROJECT ARBORIST
FOR PERIODIC MONITORING OF THE PROJECT SITE AND THE HEALTH OF THOSE TREES TO BE PRESERVED. THE
PROJECT ARBORIST SHALL BE PRESENT WHENEVER ACTIVITIES OCCUR WHICH MAY POSE A POTENTIAL THREAT TO
THE HEALTH OF THE TREES TO BE PRESERVED AND SHALL DOCUMENT ALL SITE VISITS.
THE DIRECTOR AND PROJECT ARBORIST SHALL BE NOTIFIED OF ANY DAMAGE THAT OCCURS TO A PROTECTED TREE
DURING CONSTRUCTION SO THAT PROPER TREATMENT MAY BE ADMINISTERED.
( ORD. NO. 2240, § I(EXH. B), 6-2-15 )
10
1.
2.
NOTES
GENERAL CONTRACTOR TO VERIFY EXISTING SITE CONDITIONS, STRUCTURES, DIMENSIONS
ALL ELEMENTS IN BLUE ARE TO BE DEMOLISHED
0'4' 8' 16'32' 1/8" = 1'-0"1Site Plan, Existing
1 2
3 4
5 6
11
PUBLIC WORKS & PLAN SITE NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL AND INSURING AREA ADJACENT TO WORK IS LEFT IN A CLEAN CONDITION.
UTILIZE BEST MANAGEMENT PRACTICES (BMP'S), AS REQUIRED BY THE STATE WATER RESOURCES BOARD, FOR ANY ACTIVITY,
WHICH DISTURBS SOIL.
CONTRACTOR IS RESPONSIBLE FOR ALL TEST, INSPECTIONS AND PROCEDURAL REQUIREMENTS PER CITY OF LOS GATOS.
OPERABLE SMOKE DETECTORS MUST BE IN PLACE PRIOR TO RE-OCCUPY DWELLINGS
PLUMBING & ELECTRICAL SURVEY REQUIRED FOR METER RELEASE.
ADDITIONS, ALTERATIONS OR REPAIRS SHALL CONFORM TO ANY BUILDING OR STRUCTURE WITHOUT REQUIRING THE EXISTING
BUILDING OR STRUCTURE TO COMPLY WITH ALL THE REQUIREMENTS OF THE UBC, PROVIDED THE ADDITION ALTERATION OR
REPAIR CONFORMS TO THAT REQUIRED FOR NE WBUILDING OR STRUCTURE PER UBC SECTION 3403.2.
CONTRACTOR TO VERIFY SIZE & LOCATION OF ALL UTILITY CONNECTIONS. CONTRACTOR TO PROVIDE ALL NEW UTILITY
CONNECTIONS AND/ OR UPGRADE EXISTING AS REQUIRED. CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND
APPROVALS AS REQUIRED BY GOVERNING AGENCIES.
CONTRACTOR SHALL OBTAIN ALL NECESSARY DEMOLITION PERMITS AND APPROVALS INCLUDING ASBESTOS ABATEMENT AS
PART OF THE BASE BID
PER CGBSC 301.1.1 - RESIDENTIAL BUILDINGS UNDERGOING PERMITTED ALTERATIONS, ADDITIONS OR IMPROVEMENTS SHALL
REPLACE NONCOMPLIANT PLUMBING FIXTURES WITH WATER-CONSERVING PLUMBING FIXTURES. PLUMBING FIXTURES
REPLACEMENT IS REQUIRED PRIOR TO ISSUNACE OF A CERTIFICATE OF FINAL COMPLETION, CERTIFICATE OF OCCUPANCY OR
FINAL PERMIT APPROVAL BY THE LOCAL BUILDING DEPARTMENT.
PER CGBSC 301.1.1 - WHERE ADDITION OR ALTERATION INCREASED THE BUILDING'S CONDITIONED AREA, VOLUME, OR SIZE,
THE REQUIREMENTS OF CALGreen CHAPTER 5 SHALL APPLY ONLY TO AND WITHIN THE SPECIFIC AREA OF THE ADDITION OR
ALTERATION.
Revision Schedule
Number Description Date
2 Planning 2023.03.17
6 Building Date 6
APPLICABLE CODE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
2022 CALIFORNIA BUILDING CODES PART 1, 6, 10 & 11
2022 CALIFORNIA BUILDING CODES PART 2, 2.5, 3 - 5, 8 - 9, 12
2022 CALIFORNIA RESIDENTIAL CODE PART 2.5
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA MECHANICAL CODE
2022 CALIFORNIA PLUMBING CODE
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA FIRE CODE
2022 CALIFORNIA GREEN BUILDING CODES
ALL OTHER STATE AND LOCAL LAWS, ORDINANCES AND REGULATIONS
TOWN OF LOS GATOS MUNICIPAL CODE
2022 CALIFORNIA HISTORIC BUILDING CODE
SANTA CLARA COUNTY FIRE DEPARTMENT (SCCFD) SPECIFICATIONS
1st T.O.P8' - 9 5/16"
2nd F.F9' - 10 5/16"
2nd T.O.P
14' - 11"
T.O.R.
21' - 10 11/16"
Grade/1st F.F.
0' - 0"
(D)
(E)
(R)21'-11"8'-9" 1'-1" 5'-1" 7'-0"
(E)(E)
(E)
1st T.O.P8' - 9 5/16"
2nd F.F
9' - 10 5/16"
2nd T.O.P
14' - 11"
T.O.R.21' - 10 11/16"
3
Grade/1st F.F.
0' - 0"21'-11"8'-9" 1'-1" 5'-1" 7'-0"
4
3
(P)(E)
(P)
(E)(E)
(E)
(E) DOOR TO BE NON-
FUNCTIONING
A103
1
(P)
6
MAKE-UP
AIR UNIT
1
3
LINE OF
S
I
G
H
T
1st T.O.P8' - 9 5/16"
2nd F.F9' - 10 5/16"
2nd T.O.P
14' - 11"
T.O.R.
21' - 10 11/16"
(D)
(D)(D)
Grade/1st F.F.0' - 0"21'-11"7'-0"5'-1"1'-1"8'-9"(R)
STORAGE
DEMOLITION
1st T.O.P8' - 9 5/16"
2nd F.F
9' - 10 5/16"
2nd T.O.P14' - 11"
T.O.R.21' - 10 11/16"
3
1
Grade/1st F.F.
0' - 0"7'-0"5'-1"1'-1"8'-9"(P)4'-1"21'-11"(P)
(E)
4
5
3'-6"STAMPED
CONCRETE DECK
TRELLIS,
WOOD
GUARDRAIL
2
MAKE-UP AIR UNIT1
3
LINE OF SI
G
H
T
3'-1"1st T.O.P8' - 9 5/16"
2nd F.F9' - 10 5/16"
2nd T.O.P
14' - 11"
T.O.R.
21' - 10 11/16"
Grade/1st F.F.
0' - 0"21'-11"7'-0"5'-1"1'-1"8'-9"(E)(E)(E)
DEMOLISHED SHED
1st T.O.P
8' - 9 5/16"
2nd F.F
9' - 10 5/16"
2nd T.O.P
14' - 11"
T.O.R.21' - 10 11/16"
2
Grade/1st F.F.
0' - 0"1 21'-11"7'-0"5'-1"1'-1"8'-9"(E)(E)(E)
5
LANDSCAPING,SEE/8A003
TRELLIS/WOOD
W/ STRING LIGHTS
MECHANICAL UNITSTRASH ENCLOSURE
HOOD/VENT
MAKE-UP AIR UNIT
2'-5"3'-11"SCREEN
1
3
LINE OF
S
I
G
H
T
1
3
LINE OF SI
G
H
T
6'-4"3'-1"1st T.O.P8' - 9 5/16"
2nd F.F9' - 10 5/16"
2nd T.O.P
14' - 11"
T.O.R.
21' - 10 11/16"
(E)
(D)
Grade/1st F.F.0' - 0"21'-11"7'-0"5'-1"1'-1"8'-9"(E)
(E)(E)
(E)(E)(E)
STORAGE
DEMOLITION
1st T.O.P8' - 9 5/16"
2nd F.F
9' - 10 5/16"
2nd T.O.P14' - 11"
T.O.R.21' - 10 11/16"
(P)
1
Grade/1st F.F.
0' - 0"
2
7'-0"5'-1"1'-1"8'-9"(P)21'-11"3
4
5 TRASH AREA
SCREENED BY CMU WALL
AND PLANTING
TRELLIS, WOOD
W/ STRING LIGHTS
(E) CORNER FACADE TO REMAIN
(E) DOOR TO BE NON-FUNCTIONING
(E)
(E)
(E)
(E)
(E)(E)(E)
6
MAKE-UP AIR UNITSCREEN, VERTICAL SIDING3'-1"6'-4"4'-1"ELEVATION KEYNOTES/ MATERIAL
1
2
3
(E)
(D)
EXISTING
TO BE DEMOLISHED
ELEVATION LEGEND
4
EXTERIOR VERTICAL SIDING/
JAMES HARDIE
COLOR TO MATCH EXISTING
ROOFING MATERIAL
CLASS A COMPOSITION
SHINGLES TO MATCH EXISTING
WINDOW GLASS PANES TO BE
REPLACED, TRIM AND FRAME
TO REMAIN
FIXTURES TO MINIMIZE GLARE AND
LIGHT SPILL ONTO AREAS OFF OF
THE BUILDING SITE. EXTERIOR
LIGHTING TO BE DOWNLIT
5 WOOD FENCE
1.
2.
NOTE
CONTRACTOR TO VERIFY DIMENSIONS, EXISTING CONDITIONS,
STRUCTURES, UTILITIES ON SITE.
OWNER ALLOWED TO CHOOSE ALTERNATIVE COMPLIANT
PRODUCT.
PROPOSED
TO BE REPLACED
(P)
(R)
6 ADDRESS IDENTIFICATION, CONTRAST WITH
BACKGROUND, MIN 4 INCH HIGH, MIN STROKE 0.5 INCH,
PER CBC SEC 505.1
1949-1952
1910 ATTS
LAC
E
FO ILICENS E D ARCHIT
ECTF O RNIAGORD KONW
GNO
RENEWAL 03/01/2013
4 0 4 53-C
25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025
Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/7/2024 5:44:32 PM
As indicated
A200
Elevations,
Existing &
ProposedElevations, Existing & Proposed 1/8" = 1'-0"1Elevation, Front, Existing
1/8" = 1'-0"3Elevation, Front, Proposed
1/8" = 1'-0"5Elevation, Rear, Existing
1/8" = 1'-0"7Elevation, Rear, Proposed
0'4' 8' 16'32'
PHOTO REFERENCE
0'4' 8' 16'32'
1/8" = 1'-0"2Elevation, Left, Existing
1/8" = 1'-0"4Elevation, Left, Proposed
1/8" = 1'-0"6Elevation, Right, Existing
1/8" = 1'-0"8Elevation, Right, Proposed
0'4' 8' 16'32'
0'4' 8' 16'32'
0'4' 8' 16'32'
0'4' 8' 16'32'
0'4' 8' 16'32'
0'4' 8' 16'32'
Revision Schedule
Number Description Date
1 Planning 2022.10.19
2 Planning 2023.03.17
6 Building Date 6
1st T.O.P8' - 9 5/16"
2nd F.F
9' - 10 5/16"
2nd T.O.P14' - 11"
T.O.R.21' - 10 11/16"
Grade/1st F.F.
0' - 0"6"STAIRWELL
KITCHENDINING/BAR
BAR
21'-11"7'-0"5'-1"1'-1"8'-9"TYP7" RISECRAWL SPACE
1
2
3
6
DINING
HOOD VENT/ DISCHARGE
SCREEN/ VERTICAL SIDING 4'-1"3'-0"1st T.O.P8' - 9 5/16"
2nd F.F9' - 10 5/16"
2nd T.O.P
14' - 11"
T.O.R.
21' - 10 11/16"
Grade/1st F.F.0' - 0"21'-11"7'-0"5'-1"1'-1"8'-9"2
1
CRAWL SPACE
4
7'-6"DINING
3 1/2"
12"
3 1/2"
12"8'-9"6
HALLWAY ALL-GENDER
RESTRM
9
A300
10
A300
3 1/2" / 12"5 1/2" / 12"RIDGE
RIDGED.S.D.S.
D.S.D.S.D.S.10'-9"5'-0"10'-3"3 1/2" / 12"5 1/2" / 12"22'-10"11'-1"17'-0"
8'-2"14'-6"11'-5"14'-2"
R
EEEE5 1/2" / 12"5 1/2" / 12"13'-4"12'-9"26'-0"50'-11"
(E) PARAPET
ROOF TO REMAIN
11
A300
MUA
13
A300
HOOD EXHAUST/
DISCHARGE10'-0" MINSCREEN
14'-0"10'-0" MIN1'-6"2'-0"1'-6"6'-10"6'-4"1'-2"5
A302
37
10'-9"7'-8"
2" / 12"
1
7
3
7'-8"
29"3'-2"6'-0"2"
12"
1
2
3
7
6'-0"1'-11" 2'-1"
1'-2"8'-5"1'-2"
10'-9"
1'-2"
1
7
3
10'-9"2'-0"1'-11"6'-0"A300
6
A3004
A3005
7
A300
5412
A300
8
2% SLOPE
9
6
8
D10
D148"5'-0" 1'-2"8'-5"1'-2"2'-6"5'-2"
7'-8"10'-9"1'-0"
1
7
2
5
4
3
6
7'-8"3'-11"6'-0"2"
12"9"3'-2"6'-0"1
7
3
2
7'-8"
2"
12"
UTILITY
5
STAIRWELL8'-0" 2'-11"8'-9"4'-8"10'-9"20'-9"7'-11"3'-6"FIRE RISER
HOURLY RATING: 1-HOUR
FIRE TEST REFERENCE: UL L501, cUL L501, GA FC 5420
5/8” (15.9 MM) TOUGHROCK® FIREGUARD X® PRODUCTS APPLIED
PERPENDICULAR TO 2” X 10” WOOD JOISTS 16” (406 MM) O.C. WITH
1-7/8” (48 MM) 6D NAILS 6” (152 MM) O.C. WOOD JOISTS SUPPORTING
1” (25.4 MM) NOMINAL WOOD SUB AND 1” (25.4 MM) NOMINAL FINISH
FLOOR, OR 19/32” (15.1 MM) PLYWOOD FINISHED FLOOR WITH LONG
EDGES T&G AND 15/32” (11.9 MM) INTERIOR PLYWOOD WITH XTERIOR
GLUE SUBFLOOR PERPENDICULAR TO JOISTS WITH JOINTS
STAGGERED.
APPROVED FOR ASSEMBLY:
DENSARMOR PLUS® FIREGUARD C® PRODUCTS
DENSARMOR PLUS® FIREGUARD® PRODUCTS
DENSELEMENT® BARRIER SHEATHING
DENSGLASS® FIREGUARD® SHEATHING
DENSSHIELD® FIREGUARD® TILE BACKER
TOUGHROCK® FIREGUARD C® PRODUCTS
TOUGHROCK® FIREGUARD X® MOLD-GUARD® PRODUCTS
TOUGHROCK® FIREGUARD X® PRODUCTS
TOUGHROCK® LITE-WEIGHT FIRE-RATED PRODUCTS
1 (E) ROOF PARAPET TO REMAIN
(E) WALL, (P) INSULATION
(P) HANDRAIL
2
SECTION KEY NOTES
3
4
5
(E) DORMER/ ROOF, NEW INSULATION
1-HOUR RATED FLOOR/CEILING ASSEMBLY, SEE
MAKE-UP AIR UNIT, SEE MEP PLANS
/12 A300
6
1st FF0' - 0"
2nd F.F9' - 10 5/16"
2nd T.O.P14' - 11"
T.O.R.21' - 10 11/16"
Grade/1st F.F.0' - 0"
PLYWOOD, MIN 1.25"
WITH ROOF PAN 1/2" BOLT DOWN
FAN
LINE
O
F
S
I
G
H
T
21'-11"3'-0"8'-9"SCREEN5'-8"5'-6"1
3
5'-6"D.S.
R
E
BUILDING FOOTPRINT
DOWNSPOUT, TO CONNECT TO STORM WATER PIPE
RIDGE VENT
EAVE VENT
ATTIC AREA
ROOFTOP VENT HOOD
MAKEUP AIR UNIT
LEGEND
MUA ATTS
LAC
E
FO ILICENS E D ARCHIT
ECTF O RNIAGORD KONW
GNO
RENEWAL 03/01/2013
4 0 4 53-C
25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025
Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/7/2024 5:44:47 PM
As indicated
A300
Section & Roof
Plan & Trash
EnclosureSection & Roof Plan & Trash Enclosure 1/8" = 1'-0"9 Section 1, Proposed
0'4' 8' 16'32'
1/8" = 1'-0"10 Section 2, Proposed
0'4' 8' 16'32'
0'2' 4'8'16'
•
STAIRCASE ATTIC VENT CALCS:
REQUIRED VENTILATION
64 SF / 150 = 0.43 SF (61.44 SI)
IDEAL RATIO (UPPER VENT : LOWER VENT) = 50% : 50%
= 30.72 SI : 30.72 SI
RIDGE VENT: (N.F.A. = 18 SI PER LINEAR FT)
PROVIDED LENGTH = 3 FT
3 x 18 = 48 SI
EAVE VENT:(N.F.A. 7.06 SI PER VENT)
PROVIDED HOLES = 4
7.06 x 4 = 28.24 SI
TOTAL = 48 + 28.24 = 76.24 SI> 61.44 SI, OKAY
1/4" = 1'-0"1Roof Plan, Proposed
NOTES:
**ALL ROOF SHEATHING TO USE FIRE RETARDANT TREATED ROOF SHEATHING OR APPROVED EQUIVALENT
**ALL ROOFING FINISH MATERIAL TO BE CLASS A AND SHALL MATCH EXISTING ROOF
Revision Schedule
Number Description Date
2 Planning 2023.03.17
6 Building Date 6
1/4" = 1'-0"2Trash Enclosure Roof Plan
1/4" = 1'-0"6Trash Enclosure, Left Side Elevation
1/4" = 1'-0"5Trash Enclosure, Front Elevation
1/4" = 1'-0"4Trash Enclosure, Rear Elevation
1CMU WALL
2MTL FABRICATED DOOR POWDER COATED
TRASH ENCLOSURE KEY NOTES
3GALV. STANDING SEAM MTL SHED
ROOF, GALV.
4TRASH BIN
5TRASH BIN BUMPER, CONCRETE
6
1/4" = 1'-0"3Trash Enclosure Floor Plan
1/4" = 1'-0"7Trash Enclosure, Section
7FASCIA BOARD
1/4" = 1'-0"8Trash Enclosure, Right Side Elevation
8FLOOR DRAIN, SEE CIVIL AND PLUMBING SHEETS
9J-HOOKS FOR SECURING THE DOOR FOR
SERVICING
1/8" = 1'-0"11 Section, Stairwell
1" = 1'-0"12 1-Hour Fire Rated Ceiling/ Floor
PERMEABLE PAVERS
1/8" = 1'-0"13 Section, Hood
3Section View, Front
4Section View, Rear ATTS
LAC
E
FO ILICENS E D ARCHIT
ECTF O RNIAGORD KONW
GNO
RENEWAL 03/01/2013
4 0 4 53-C
25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025
Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/7/2024 5:45:49 PM
A301
Perspective Views
& DiagramPerspective Views & DiagramTRASH AREA
SCREENED BY 6'-0" WOOD FENCE
AND LANDSCAPING
LANDSCAPING, SEE A003
OUTDOOR DECK/ DINING AREA
TRELLIS, STRING LIGHTING
WITH WOOD FENCE/ SCREENING, 3'-6"
ADDITION/
STAIRCASE
ACCESSIBLE RAMP
WITH HANDRAILS
PERMEABLE
PAVERS
DRY STACKED
RETAINING WALL
WOOD FENCE 3'-6", ENCLOSING
OUTDOOR DINING AREA
(E) POWER POLE TO REMAIN
(E) CORNER FACADE TO REMAIN
(E) DOOR TO BE NON-FUNCTIONING
(P) ENTRY DOOR TO BE
REHABILITATED TO MATCH
1919-1952 PHOTO, SEE A200
(E) HORIZONTAL SIDING TO REMAIN
CONCRETE RETAINING WALL
(E) WINDOWS AND TRIM
TO REMAIN, GLASS PANE
TO BE REPLACED
(E) ROOF
STRUCTURE TO
REMAIN
VERTICAL SIDING, COLOR
TO MATCH EXISTING
Revision Schedule
Number Description Date
ROOFTOP VENT WITH
SCREEN, VERTICAL SIDING
ROOFTOP VENT
WITH SCREEN,
VERTICAL SIDING
FAN
LINE O
F
S
I
G
H
T
SCREEN5'-8"13
5'-6"21'-11"3'-1"1st T.O.P
8' - 9 5/16"
2nd F.F9' - 10 5/16"
2nd T.O.P14' - 11"
T.O.R.
21' - 10 11/16"
Grade/1st F.F.0' - 0"
(P)7'-0"5'-1"1'-1"8'-9"(P)21'-11"(E)(E)(E)
(E)
(E)(E)(E)
SCREEN, VERTICAL SIDING3'-1"6'-4"4'-1"5'-8"LINE OF S
I
G
H
T
LI
N
E
O
F
S
I
G
H
T ATTS
LAC
E
FO ILICENS E D ARCHIT
ECTF O RNIAGORD KONW
GNO
RENEWAL 03/01/2013
4 0 4 53-C
25 West Main St.SCALE R E S I D E N T I A L / C O M M E R C I A L GORDON K WONG, ARCHITECT LIC# 34045710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 315-2125GORDONKWONG@GKWARCHITECTS.COMRENEWAL 08/31/2025
Los Gatos, CA, 95030PROJECT REPJENNY C. WONG710E MCGLINCY LANE SUITE 109CAMPBELL, CA 95008 (408) 796-18456/7/2024 5:46:36 PM
1" = 10'-0"
A302
Perspective &
Section ViewsPerspective & Section ViewsRevision Schedule
Number Description Date
1 Planning 2022.10.19
2 Planning 2023.03.17
1Street View, Rear Corner
2Street View, Corner 3 Street View, Front
4 Street View, Rear Patio
1" = 10'-0"5Section, Hood..
1" = 10'-0"6Elevation, Right, Proposed.
HOOD VENT IS NOT VISIBLE
FROM THE REAR PATIO
HOOD VENT/ VERTICAL
SIDING SCREEN
HOOD VENT/ VERTICAL
SIDING SCREEN HOOD VENT IS NOT VISIBLE
FROM FRONT STREET VIEW