Loading...
Item 3 - Addendum and Attachment 5 PREPARED BY: SEAN MULLIN, AICP Associate Planner 110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874 www.losgatosca.gov TOWN OF LOS GATOS HISTORIC PRESERVATION COMMITTEE REPORT MEETING DATE: 05/26/2021 ITEM NO: 3 ADDENDUM DATE: May 25, 2021 TO: Historic Preservation Committee FROM: Joel Paulson, Community Development Director SUBJECT: Preliminary Review of a Request for Construction of Exterior Alterations and an Addition to an Existing Pre-1941 Single-Family Residence on Property Zoned R-1:8 Located at 320 Johnson Avenue. APN 529-39-070. Property Owner: Steve and Gina Sprich. Applicant: Steven Plyler, De Mattei Construction. Project Planner: Sean Mullin. DISCUSSION: The applicant has revised the dimensions of the front porch columns proposed to replace the existing four-inch square columns. The previous plans proposed six-inch square columns (Attachment 4). The applicant now proposes nine and one-quarter inch square columns (Attachment 5). ATTACHMENTS: Previously received with the May 26, 2021 Staff Report: 1. 1990 Bloomfield Survey 2. Sanborn Map Exhibit 3. Section 3.9, Residential Design Guidelines 4. Development Plans Received with this Addendum: 5. Revised Development Plans This Page Intentionally Left Blank E / LE / LN Cross Section 13 A. A SIGN SHALL BE POSTED STATING THAT THE TOWN OF WOODSIDE CONSTRUCTIONHOURS ARE LIMITED TO MONDAY THROUGH FRIDAY BETWEEN 7:30 A.M. AND 5:30 P.M.;SATURDAY BETWEEN 8:00 A.M. AND 1:00 P.M.;SUNDAY; NO CONSTRUCTION ALLOWED.THERE SHALL BE NO DELIVERIES OR RUNNING OF EQUIPMENT PRIOR TO THESE TIMES.FAILURE TO COMPLY WITH TOWN CONSTRUCTION HOURS MAY RESULT IN A STOPWORK NOTICE.B. AT NO TIME SHALL THE STREET BE CLOSED OR BLOCKED. FLAGMEN SHALL BE USEDAT ALL TIMES WHEN DELIVERIES OR CONSTRUCTION RESTRICT ANY PORTION OF THERIGHT OF WAY.C. ON-STREET PARKING IS NOT ALLOWED. ALL CONSTRUCTION PARKING MUST BE ON-SITE.D. ALL PROTECTIVE FENCING SHALL BE MAINTAINED IN PLACE THROUGHOUT THEDURATION OF CONSTRUCTION.E. NO DEMOLITION OR CONSTRUCTION MAY COMMENCE UNTIL THE PROTECTIVEFENCING HAS BEEN INSTALLED, INSPECTED, AND APPROVED BY THE PORTOLA VALLEYPUBLIC WORKS INSPECTOR.134.6444.01 42.34110PG&E CABLE TV SSCO W/M 25' FSB 8' SSB8' SSB20' RS B 9"dia T R E E TO R E M AI N 9"dia T R E E TO R E M AI N 6" di a T R E E TO R E M AI N 4"dia T R E E S TO B E REM O V E D 70 CONCRETE WALK 227 SF FIRST FLR ADDITION (ANGLE DOUBLE HATCHED) 7 SF FIRST FLR ADDITION (ANGLE DOUBLE HATCHED) (E) 1020 SF 2ND FLR (SHADED) 21 SF FIRST FLR AREA REMOVED (CROSS ANGLE HATCHED)3' ACCSRY SSBIF 5' SEPARATION(E) 1300 SF 1ST FLR WIDE ANLGE HATCH (E) PORCH (E) POTTING SHED PROPOSED 381 SF DECK8' SSBPROP'D 64 SF PORCH EXTENSION (N) FPL 320 JO H N S O N A V E 364 SF (E) GARAGE (HATCHED LINE) 23'10" (N) SIDE SETBACK 4" di a T R E E T O BE R E M O V E D TITLE SHEETCITY OF SARATOGA: CONSTRUCTION WORK HOURS: MONDAY - FRIDAY 7:30AM - 6:00PM SATURDAYS 9:00AM - 5:00PM SUNDAYS AND WEEKDAY HOLIDAYS PROHIBITED SITE MANAGEMENT: A. SITE SHALL BE MAINTAINED CLEAN AT ALL TIMES AND CONSTRUCTION DEBRIS HAULED OFF ON A REGULAR BASIS. B. "BEST MANAGEMENT PRACTICE" SHALL BE IN PLACE AND MAINTAINED DURING THIS PROJECT FOR PROTECTION OF ANY POLLUTANTS ENTERING THE EXISTING STORMWATER SYSTEM. COVERSHEET NOTES FOR SARATOGA RESPONSES TO PLAN CHECK COMMENTS SHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:09/18/15HPC SET 5/24/2021 T1DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABY DATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021 Historic Preservation (HPC) | The Los Gatos CA Official Site! SHEET INDEX PROJECT DIRECTORY SCOPE OF WORK: SCOPE OF WORK: 230 JOHNSON AVE NET ADDITION OF 213 SF TO FIRST FLOOR OF EXISTING 2342 SF 2 STORY RESIDENCE RE-COMPARTMENTALIZE SOME OF FIRST FLOOR ADD 64 SF EXTENSION OF FRONT PORCH ADD 381 SF NEW REAR DECK MOVE FPL LOCATION TO LEFT SIDE TOWARD REAR N Scale: 1/8"=1'-0" SITE/ROOF PLAN PROJECT LOCATION ToDo:ToDo: 1. PLACE HOLDER, BECAUSE IT WON'T FORMAT WITHOUT IT. SHEET INDEX T1 TITLE SHEET A2.1 (E) FLOOR PLANS A2.2 PROPOSED FLOOR PLANS A2.3 (E) GAR FLR PLAN & ELEVATIONS A3.1 (E) ELEVATIONS A3.2 PROP'D ELEVATIONS P1 (E) HOUSE AND GARAGE PICTURES The drawings, plans, models, designs, specifications, reports, photographs, computer print-outs in association with the design development are intended for the use by the De Mattei Construction Inc. This work is intended solely for Owner. The contracted drawings are madeavailable for informational purposes only in relation to (Project). Drawings may not be copied, reproduced or distributed in anyway without written consent from De Mattei Construction Inc. De Mattei Construction Inc. cannot be held liable for any unauthorized use of the drawingsCONSTRUCTION SHALL CONFORM TO: 2016 California Building Code 2016 California Residential Code 2016 California Plumbing Code 2016 California Mechanical Code 2016 California Electrical Code 2016 Energy Code 2016 Green Building Code 2016 California Fire Code 2016 California Reference Standards Code PROPERTY OWNER: Steven and Gina Sprich 320 Johnson Ave, LG, Ca 95030 stevesprich@gmail.com gina.sprich@gmail.com DESIGNER/CONTRACTOR: Steven W Plyler, (408) 390-5971 steve@demattei.com DE MATTEI CONSTRUCTION, INC. 1794 the Alameda San Jose, Calif 95126 (408) 295-7516 PROPERTY OWNER: John and Carol Traub (408) 230-9568, (408) 472-5648 1741 University Ave, SJ, Ca 95126 4x ENGINEERING, INC 4340 Stevenscreek Blvd Suite #240 San Jose, Calif 95129 (408) 642-5464 DESIGNER/CONTRACTOR: Steven W Plyler, (408) 390-5971 steve@demattei.com DE MATTEI CONSTRUCTION, INC. 1794 the Alameda San Jose, Calif 95126 (408) 295-7516DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.SPRICH RESIDENCE REMODEL ASSESSOR'S PARCEL MAP RENDERING w/ PROPOSED ADDITION ATTACHMENT 5 E / LE / LE / LE / LE / L4x4 Post 4x4 Post 4x4 Post 4x4 Post4x4 Post 4x4 Post4x4 Post 4x4 Post4x4 Post 4x4 Post 10'-11 11/16"5'-8 1/2"26'-4 15/16"16'-0 13/16"6'-0 1/2"14'-0 1/2"40'-0 11/16"12'-4 3/16"17'-9 1/8"5'-8 1/2"6'-1"2'-8 7/8"46'-1 11/16"35'-9 13/16" 18'-4 1/2"18'-0 1/2"9'-11"3'-4"8'-5 1/2"21'-4 1/2"A.A SIGN SHALL BE POSTED STATING THAT THE TOWN OF WOODSIDE CONSTRUCTIONHOURS ARE LIMITED TO MONDAY THROUGH FRIDAY BETWEEN 7:30 A.M. AND 5:30 P.M.;SATURDAY BETWEEN 8:00 A.M. AND 1:00 P.M.;SUNDAY; NO CONSTRUCTION ALLOWED.THERE SHALL BE NO DELIVERIES OR RUNNING OF EQUIPMENT PRIOR TO THESE TIMES.FAILURE TO COMPLY WITH TOWN CONSTRUCTION HOURS MAY RESULT IN A STOPWORK NOTICE. B.AT NO TIME SHALL THE STREET BE CLOSED OR BLOCKED. FLAGMEN SHALL BE USEDAT ALL TIMES WHEN DELIVERIES OR CONSTRUCTION RESTRICT ANY PORTION OF THERIGHT OF WAY. C.ON-STREET PARKING IS NOT ALLOWED. ALL CONSTRUCTION PARKING MUST BE ON-SITE. D.ALL PROTECTIVE FENCING SHALL BE MAINTAINED IN PLACE THROUGHOUT THEDURATION OF CONSTRUCTION.E.NO DEMOLITION OR CONSTRUCTION MAY COMMENCE UNTIL THE PROTECTIVEFENCING HAS BEEN INSTALLED, INSPECTED, AND APPROVED BY THE PORTOLA VALLEYPUBLIC WORKS INSPECTOR. AT LEAST ONE FIXTURE IN EACH BATHRM, LAUNDRY, UTILITY RM AND GARAGE SHALL BE CONTROLLED BY A VACANCY SENSOR. CEC 150.0(k)2J LI VIN G ROOM DIN ING ROOM KITCHEN PORCH GARAGE 15' FSB 8' SSB3' ACCSRY SSBIF 5' SEPARATION4 " d ia T R E E S T O B E R E M O V E D BEDROOM BEDROOM BEDROOM BATH CLOSET 9 "d ia T R E E T O R E M A IN 9 "d ia T R E E T O R E M A IN 4 " d ia T R E E T O B E R E M O V E D 6 " d ia T R E E T O R E M A IN (E) POTTING SHED UP DN20'-5 3/4"34'-0 7/16"6'-8 11/16"6'-0 1/4"15'-4 1/8"8'-0 1/2"6'-0 1/4"22'-3 1/4"9'-7 9/16"11'-9 3/16"48 46 100 BEDROOM M. CLOSET M. BEDROOM BATH LAUNDRYCLOSETLINENBALCONY HALL DN OPEN AREA A.A SIGN SHALL BE POSTED STATING THAT THE TOWN OF WOODSIDE CONSTRUCTIONHOURS ARE LIMITED TO MONDAY THROUGH FRIDAY BETWEEN 7:30 A.M. AND 5:30 P.M.;SATURDAY BETWEEN 8:00 A.M. AND 1:00 P.M.;SUNDAY; NO CONSTRUCTION ALLOWED.THERE SHALL BE NO DELIVERIES OR RUNNING OF EQUIPMENT PRIOR TO THESE TIMES.FAILURE TO COMPLY WITH TOWN CONSTRUCTION HOURS MAY RESULT IN A STOPWORK NOTICE. B.AT NO TIME SHALL THE STREET BE CLOSED OR BLOCKED. FLAGMEN SHALL BE USEDAT ALL TIMES WHEN DELIVERIES OR CONSTRUCTION RESTRICT ANY PORTION OF THERIGHT OF WAY. C.ON-STREET PARKING IS NOT ALLOWED. ALL CONSTRUCTION PARKING MUST BE ON-SITE. D.ALL PROTECTIVE FENCING SHALL BE MAINTAINED IN PLACE THROUGHOUT THEDURATION OF CONSTRUCTION.E.NO DEMOLITION OR CONSTRUCTION MAY COMMENCE UNTIL THE PROTECTIVEFENCING HAS BEEN INSTALLED, INSPECTED, AND APPROVED BY THE PORTOLA VALLEYPUBLIC WORKS INSPECTOR. KEY WALL TO B E DEMOLISHE D (E) WALL (E) FLOOR PLANSSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 A2.1DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021 X LINEAL FEET OF EAVE W/2X RAFTERS @ 16" O.C.: X'/16" = ±X AVAILABLE BLOCKS NEW UNDER FLOOR AREA TO BE VENTED = XXX SQ.FT. NEW ATTIC AREA TO BE VENTED = XXX SQ.FT. XXX/150(144) = XXX SQ.IN. NFVA REQUIRED EXISTING FLOOR AND DEMO PLANS XXX/150(144) = XXX SQ.IN. NFVA REQUIRED 1 FLOOR VENT UNIT: 13.5" X 7.5" = 101.25 SQ.IN NFVA 1 EAVE BLOCKING VENT UNIT: 14" x 5.5" = 77 SQ.IN NFVA X FLOOR VENTS PROVIDED, DISTRIBUTED EVENLY: (X) x XXX SQ.IN = XXX SQ.IN. NFVA XXX SQ.IN. NFVA PROVIDED > XXX SQ.IN. NFVA REQUIRED X EAVE VENTS PROVIDED, DISTRIBUTED EVENLY: (X) x X SQ.IN. = XXX SQ.IN. NFVA XXX SQ.IN. NFVA PROVIDED > XXX SQ.IN. NFVA REQUIRED LEGEND: EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED NEW INTERIOR CONSTRUCTION; 2x4 WD. STUD, 1/2" GYP. BD. EACH SIDE NEW EXTERIOR CONSTRUCTION; SEE 5/A3.2 NEW 1-HR FIRE RATED WALL; 2x4 WD. STUD, 5/8" TYPE "X" GYP. BD. EACH SIDE. SEE PLAN FOR LOCATIONS. LEGEND: EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED LEGEND: EXISTING CONSTRUCTION NEW CONSTRUCTION PLUMBING: A.ALL NEW TOILETS SHALL HAVE AN EFFECTIVE FLUSH VOLUME NOT TO EXCEED 1.28 GALLONS PER FLUSH. B.LAVATORY FAUCETS SHALL NOT EXCEED 1.2 GPM AT 60 PSI (MIN. SHALL NOT BE LESS THAN 0.8 GPM AT 20 PSI). C.ALL NEW SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF 2.0 GALLONS PER MINUTE AT 80 PSI. D.ALL NEW KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE AT 60 PSI AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. (TYP) STAIR NOTES STAIR GENERAL NOTE: -MAX RISE 7 3/4", MIN RUN 10", FOR TAPERED TREADS MIN. TREAD WIDTH REQUIRED 12" FROM NARROW END WHICH SHALL NOT BE LESS THAN 6" AT ANY POINT -MIN. HEADROOM IS 6'8" -MIN. CLEAR WIDTH IS 36" -HAND RAILS SHALL BE 34" TO 38" ABOVE TREADS AND RETURN TO WALLS PROTECT UNDERSTAIR WITH 1 HR CONSTRUCTION, 5/8" TYPE "X" SHEETROCK INSIDE WALLS AND CEILING HANDRAILS SHALL HAVE 1-1/4 - 2 INCH GRIPPABLE CROSS SECTION, NO SHARP CORNERS, EXTEND CONTINUOUSLY FROM TOP TO BOTTOM RISER, AND TERMINATE AT NEWEL POSTS OR RETURN TO WALLS. (TYP) HANDRAILS: "EXCEPTION #3 STAIRWAYS HAVING LESS THAN FOUR RISERS AND SERVING ON INDIVIDUAL DWELLING UNIT IN GROUP R, ......NEED NOT HAVE HANDRAILS" SPACE RAIL MEMBERS SUCH THAT A 4" dia SPHERE CANNOT PASS THROUGH GUARDRAILS, HEIGHT: "THE TOP OF GUARDRAILS SHALL NOT BE LESS THAN 42 INCHES IN HEIGHT. GUARDRAILS: " WHERE REQUIRED. ....LANDINGS,.. BALCONIES OR PORCHES,WHICH ARE MORE THAN 30 INCHES ABOVE GRADE OR FLOOR BELOW,......SHALL BE PROTECTED BY A GUARD RAIL." LANDING: REQ'D 36" DEEP (IN THE DIRECTION OF TRAVEL) x WIDTH OF DOOR MAXIMUM DROP FROM TOP OF THRESHOLD IS 7.75" FOR IN SWINGING, 1/2" FOR OUT SWINGING DOORS, & 3/4" FOR SLIDING DOORS PER CBC 1008.1.5 - 1008.1.6 (TYP) ACCESS NOTES: A. EGRESS: (FOR NEW CONSTRUCTION AREAS) PER CBC 1026.1-1026.5. SLEEPING ROOMS MUST HAVE AN OPERABLE WINDOW OR EXTERIOR DOOR FOR EMERGENCY MEANS OF EGRESS WHICH OPENS DIRECTLY ONTO A PUBLIC STREET, ALLEY, YARD OR EXTERIOR COURT. PROVIDE SILL HEIGHT NOT OVER 44" ABOVE FLOOR, 5.7 SF OF OPERABLE AREA, 24" NET CLEAR OPENING HEIGHT, 20" NET CLEAR OPENING WIDTH. B. ATTIC ACCESS: MIN 22" x 30" PER SECTION R807 CRC 2016 C. UNDERFLOOR ACCESS: 18" x 24" MIN. WATER HEATER TO BE INSTALLED ON 18" TALL STAND. USE 1 1/2" x 16ga STRAP w/ 3/8" dia X 3" LONG LAG AT POINTS WITH IN THE UPPER AND LOWER ONE THIRD OF ITS VERTICAL DIMENSION, THE LOWER ANCHOR STRAP LOCATED TO MAINTAIN A MINIMUM DISTANCE OF 4 INCHES ABOVE THE CONTROLS. MIN RECOVERY RATE OF WATER HEATER EQUIVALENT TO NOT LESS THAN THE FIRST HOUR RATING OF 67 GALLONS (TYP) GARAGE NOTES: A. PER TABLE 3-B UBC 302.4-GARAGE REQUIRES 1 HOUR OCCUPANCY SEPARATION CONSTRUCTION ON GARAGE SIDE ONLY WHERE GARAGE ADJOINS THE REST OF THE BUILDING. 5/8" TYPE X SHEETROCK ALL WALLS AND SURFACES BETWEEN GARAGE AND HOUSE (TYP)B. PER UBC 302.4, USE A 1 3/4" SOLID WOOD SELF-CLOSING DR w/ A FIRE RATING OF NOT LESS THAN 20 MIN. C. PER CBC 302.2 AND 302.4.3, FOR HABITABLE SPACES ABOVE GARAGE USE, 5/8" TYPE "X" GYP BD SHALL BE APPLIED TO GARAGE CEILING AND SUPPORTING MEMBERS (eg BEAMS COLUMNS AND BEARING WALLS). D. PER CBC 302.2 AND 302.4.3, FOR HABITABLE SPACES ABOVE GARAGE SPACING OF RAFTERS/CEILING JOISTS SHALL BE A MAXIMUM OF 16" o.c. (PER CBC TABLE 7-C) OR USE 2 LAYERS 5/8" TYPE "X" GYP BD APPLIED TO FRAMING @24" o.c. (TYP) WATER HEATER NOTES: PROVIDE 1 SF/2 KBTU COMBUSTION AIR AT BOTH WITHIN 12" OF FLOOR AND 12" OF CEILING BATHROOM: A.WATER CLOSETS SHALL BE LOCATED IN SPACES NOT LESS THAN 30" IN WIDTH AND 24" IN FRONT. B.WATER RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT EXPOSURE TO WATER. CRC 702.5.7.1 C.BACKER FOR SHOWER AND TUB SHOWER WALLS TO BE FIBER-CEMENT, FIBER REINFORCED CEMENTITIOUS BACKER UNITS, GLASS MAT GYPSUM BACKERS OR FIBER-REINFORCED GYPSUM BACKERS TO A MIN. HEIGHT OF 72" ABOVE THE FLOOR. D.USE 2X8 WOODEN BACKING IN ALL BATHROOM WALLS AT WATER CLOSET SHOWER AND BATHTUB, LOCATED AT 34" FROM FLOOR TO CENTER OF THE BACKING SUITABLE FOR THE ADDITION OF GRAB BARS. E.DOORS AND PANELS OF TUB AND SHOWER ENCLOSURES SHALL BE FULLY TEMPERED LAMINATED SAFETY GLASS OR APPROVED PLASTIC. F.SHOWER COMPARTMENTS SHALL HAVE MIN INTERIOR FLOOR AREA OF 1024 SQ IN AND ABLE TO CONTAIN A 30" DIA. CIRCLE. G.SHOWER AND TUB SHOWER COMBINATION IN ALL BUILDING SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE. (TYP) WINDOW & DOOR NOTES:A. NEW WINDOWS SHALL HAVE A MAXIMUM U FACTOR OF 0.27 & SHADING COEFFICIENT SGHC OF 0.20 B. NEW DOORS SHALL HAVE A MAXIMUM U FACTOR OF 0.27 & SHADING COEFFICIENT SGHC OF 0.20 C. PROVIDE WEATHERSTRIPPING BETWEEN UNHEATED STORAGE OR ATTIC SAME AS EXTERIOR DOORS (TYP) D. FOR LIGHT REQUIREMENT PROVIDE A WINDOW AREA OF NOT LESS THAT 10% OF FLOOR AREA NOR LESS THAT 10 SF, FOR VENTILATION PROVIDE AN OPERABLE WINDOW AREA OF NOT LESS THAN 5% OF FLOOR AREA NOR LESS THAN 5 SF. E. WINDOW IN SHOWER LESS THAN 70" ABOVE THE DRAIN OUTLET TO BE TYPE NOT ADVERSELY AFFECTED BY MOISTURE (TYP) RECYCLE NOTES: MINIMUM OF 65% OF THE NON-HAZARDOUS CONSTRUCTION AND DEMOLITION DEBRIS WILL BE RECYCLED AND/OR SALVAGED FOR REUSE IN ACCORDANCE WITH SECTIONS 4,408.2, 4.408.3, OR 4.408.4. CGBSC SECTION 4.408.L (TYP) HVAC NOTES: A. PROVIDE 1 SF/2 KBTU COMBUSTION AIR AT BOTH WITHIN 12" OF FLOOR AND 12" OF CEILING B. PROVIDE 30"x30" MIN ACCESS TO FURNACE IN ATTIC w/30" x 30" MIN LEVEL SERVICE AREA IN FRONT OF FURNACE . FURNACE SHALL NOT BE LOCATED GREATER THAN 20' FROM ACCESS OPENING. PROVIDE SWITCHED LIGHT AND RECEPTACLE AT ATTIC SPACE ENTRANCE. PROVIDE 24" WIDE PLATFORM PATH TO FAU C. PROVIDE 30"x30" MIN ACCESS TO FURNACE IN CRAWL SPACE w/30" x 30" MIN LEVEL SERVICE AREA IN FRONT OF FURNACE IN CRAWL SPACE. FURNACE SHALL NOT BE LOCATED GREATER THAN 20' FROM ACCESS OPENING. PROVIDE SWITCHED LIGHT AND RECEPTICLE AT CRAWL SPACE ENTRANCE D. ATTIC ACCESS THROUGH BEDROOM OR BATHROOM TO HVAC NOT ALLOWED E. CENTRAL HEATING BOILERS AND FURNACES. LOCATION: CENTRAL HEATING FURNACE AND LOW PRESSURE BOILER INSTALLATIONS IN BEDROOMS OR BATHROOMS SHALL COMPLY WITH ONE OF THE FOLLOWING [NFPA 54:9.3.1] (1)CENTRAL HEATING FURNACES AND LOW-PRESSURE BOILERS MAY BE INSTALLED IN A CLOSET LOCATED IN THE BEDROOM OR BATHROOM, PROVIDED THE CLOSET IS EQUIPPED WITH A LISTED, GASKETED DOOR ASSEMBLY AND A LISTED SELF- CLOSING DEVICE. THE SELF-CLOSING DOOR ASSEMBLY SHALL BE THE REQUIREMENTS OF CODE. ALL COMBUSTION AIR FOR SUCH INSTALLATIONS SHALL BE OBTAINED FROM THE OUTDOORS. THE CLOSET SHALL BE FOR THE EXCLUSIVE USE OF THE CENTRAL HEATING FURNACE OR LOW-PRESSURE BOILER. (2)CENTRAL HEATING FURNACES AND LOW-PRESSURE BOILERS SHALL BE OF THE DIRECT-VENT TYPE. SELF-CLOSING DOORS. SELF-CLOSING DOORS SHALL SWING EASILY AND FREELY AND SHALL BE EQUIPPED WITH A SELF-CLOSING DEVICE TO CAUSE THE DOOR TO CLOSE AND LATCH EACH TIME IS OPENED. THE CLOSING MECHANISM SHALL NOT HAVE A HOLD-OPEN FEATURE. GASKETING: GASKETING ON GASKET DOORS OR FRAMES SHALL BE FURNISHED ONLY IN ACCORDANCE WITH THE PUBLISHED LISTING OF THE DOOR, FRAME, OR GASKETING MATERIAL MANUFACTURER. EXCEPTION: WHERE ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION, GASKETING OF NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIAL (SEE NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION) SHALL BE PERMITTED TO BE APPLIED TO THE FRAME, PROVIDED CLOSING AND LATCHING OF THE DOOR ARE NOT INHIBITED. DISHWASHER NOTE: NO DOMESTIC DISHWASHING MACHINE SHALL  BE DIRECTLY CONNECTED TO A DRAINAGE SYSTEM OR FOOD WASTE DISPOSER WITHOUT  THE USE OF  AN APPROVED DISHWASHER AIR GAP FITTING ON THE DISCHARGE SIDE OF THE DISHWASHING MACHINE. LISTED AIRGAPS SHALL BE INSTALLED WITH THE FLOOD- LEVEL (FL) MARKING AT OR ABOVE THE FLOOD LEVEL OF THE SINK OR DRAIN BOARD, WHICHEVER IS HIGHER.  CPC SEC. 807.3 INSULATION NOTE: NOTE ON THE PLANS THAT FOR ALL REMODELS, INSULATION MEETING THE MANDATORY FEATURE REQUIREMENTS IN THE CAL IFORNIA ENERGY CODE SHALL BE INSTALLED AT CEILINGS, WALLS, FLOORS AND WATER PIPES, WHEN THESE AREAS ARE EXPOSED DURING REMODELING.  SCC CODE  12.10.250 BATHRM/LAUNDRY VENTILATION NOTES A.EACH BATHROOM SHALL BE MECHANICALLY VENTILATED w/ ENERGY STAR COMPLIANT FANS AND DUCTED TO TERMINATE OUTSIDE THE BLDG (AT LEAST 3' AWAY FROM ANY OPENING). UNLESS FUNCTIONING AS WHOLE HOUSE FAN, FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL (ADJUSTABLE RANGE 50% MIN, - 80% MAX.) B.EXHAUST FANS SHALL HAVE A MIN. OF 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION AND BE ENERGY STAR COMPLIANT AND BE EQUIPPED WITH A HUMIDISTAT AND HUMIDITY CONTROL C.PROVIDE MECHANICAL VENTILATION SYSTEM CAPABLE OF 5 AIR CHANGES/HR AND DISCHARGE TO EXTERIOR. TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS SHALL BE A MINIMUM OF 3 FEET FROM PROPERTY LINES OR ANY OPENINGS INTO THE BUILDING (i.e., DRYERS, BATH AND UTILITY FANS, ETC., MUST BE 3 FEET AWAY FROM DOORS WINDOWS, OPENING SKYLIGHTS OR ATTIC VENTS). BACK DRAFT DAMPER SHALL BE PROVIDED USE SMOOTH METAL D.EXHAUST FANS (EXCLUDES KITCHEN EXHAUST HOOD) SHALL BE SWITCHED SEPARATE FROM LIGHTING (OR UTILIZE A DEVICE WHERE LIGHTING CAN BE TURNED OFF WHILE FAN IS RUNNING) E.DUCT FOR DRYER EXHAUST USE A MAX DUCT LENGTH OF 14' TO OUTSIDE w/ BACKDRAFT DAMPER AND TWO 90 DEGREE ELBOWS AND A MIN. OF 4" DIA. R311.7.6 Landings for stairways. There shall be a floor or landing at the top and bottom of each stairway. The minimum width perpendicular to the direction of travel shall be no less than the width of the flight served… Exception: A floor or landing is not required at the top of an interior flight of stairs, including stairs in an enclosed garage, provided a door does not swing over the stairs.DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.FIRST FLOOR PLANSECOND FLOOR PLAN Scale: 1/4"=1'-0" UP E / LE / LE / LE / LE / LS2 A3.2 20'-1 5/8" 5'-4"9'-8"8'-0" 10'-10"5'-8"2'-5" 5'-7 1/2" 3'-7 11/16"5'-0"5'-7"7'-0"13'-5"10'-10"17'-6"2'-5"6'-4 1/2"7'-3 1/2"5'-7"5'-6 3/4"12'-0 3/16"7'-9 1/4"11'-1 1/2"2'-3"2'-6"2'-6"1'-0"1'-0"6'-1"18'-4 1/2"18'-0 1/2"9'-11"3'-4"8'-5 1/2"21'-4 1/2"6'-0 1/4"46'-1 11/16"BEDROOM FAM ILY ROOM 48" PICKET FENCE 2.5, 5 OC PORCH B EDROOM KITCHEN PANTRY EXE RCISE R OOM BATH POW DER 9'-6" APPROX. 5'+ CONCRETE WALK HALL PROPOSED DEC K (E) POTTING SHED ADDITION (E) GARAGE REPL (E) 4x4 POSTS w/ 9 1/4" SQ POSTS (N) 9 1/4" SQ PORCH POST RELOCATE (E) FRONT DR RELOCATED (E) WINDOW (N) WINDOW BEDROOM M. CLOSET M. BEDROOM BATH LINENBALCONY CLOSETOPEN AREALAUNDRYHALL PATCH WHERE WALLS REM'D PATCH WHERE 1/2 WALLS REM'D (N) WALL K EY (E) WALL PROPOSED FLOORPLANSSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 A2.2DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.FIRST FLOOR PLANSECOND FLOOR PLAN Scale: 1/4"=1'-0" PROPOSED FLOOR PLANS 9"A.A SIGN SHALL BE POSTED STATING THAT THE TOWN OF WOODSIDE CONSTRUCTIONHOURS ARE LIMITED TO MONDAY THROUGH FRIDAY BETWEEN 7:30 A.M. AND 5:30 P.M.;SATURDAY BETWEEN 8:00 A.M. AND 1:00 P.M.;SUNDAY; NO CONSTRUCTION ALLOWED.THERE SHALL BE NO DELIVERIES OR RUNNING OF EQUIPMENT PRIOR TO THESE TIMES.FAILURE TO COMPLY WITH TOWN CONSTRUCTION HOURS MAY RESULT IN A STOPWORK NOTICE. B.AT NO TIME SHALL THE STREET BE CLOSED OR BLOCKED. FLAGMEN SHALL BE USEDAT ALL TIMES WHEN DELIVERIES OR CONSTRUCTION RESTRICT ANY PORTION OF THERIGHT OF WAY. C.ON-STREET PARKING IS NOT ALLOWED. ALL CONSTRUCTION PARKING MUST BE ON-SITE. D.ALL PROTECTIVE FENCING SHALL BE MAINTAINED IN PLACE THROUGHOUT THEDURATION OF CONSTRUCTION.E.NO DEMOLITION OR CONSTRUCTION MAY COMMENCE UNTIL THE PROTECTIVEFENCING HAS BEEN INSTALLED, INSPECTED, AND APPROVED BY THE PORTOLA VALLEYPUBLIC WORKS INSPECTOR. KEY WA LL TO BE DEMOLISHE D (E) WALL 18'-4 1/2"18'-0 1/2"9'-11"3'-4"8'-5 1/2"21'-4 1/2"A.A SIGN SHALL BE POSTED STATING THAT THE TOWN OF WOODSIDE CONSTRUCTIONHOURS ARE LIMITED TO MONDAY THROUGH FRIDAY BETWEEN 7:30 A.M. AND 5:30 P.M.;SATURDAY BETWEEN 8:00 A.M. AND 1:00 P.M.;SUNDAY; NO CONSTRUCTION ALLOWED.THERE SHALL BE NO DELIVERIES OR RUNNING OF EQUIPMENT PRIOR TO THESE TIMES.FAILURE TO COMPLY WITH TOWN CONSTRUCTION HOURS MAY RESULT IN A STOPWORK NOTICE. B.AT NO TIME SHALL THE STREET BE CLOSED OR BLOCKED. FLAGMEN SHALL BE USEDAT ALL TIMES WHEN DELIVERIES OR CONSTRUCTION RESTRICT ANY PORTION OF THERIGHT OF WAY. C.ON-STREET PARKING IS NOT ALLOWED. ALL CONSTRUCTION PARKING MUST BE ON-SITE. D.ALL PROTECTIVE FENCING SHALL BE MAINTAINED IN PLACE THROUGHOUT THEDURATION OF CONSTRUCTION.E.NO DEMOLITION OR CONSTRUCTION MAY COMMENCE UNTIL THE PROTECTIVEFENCING HAS BEEN INSTALLED, INSPECTED, AND APPROVED BY THE PORTOLA VALLEYPUBLIC WORKS INSPECTOR. AT LEAST ONE FIXTURE IN EACH BATHRM, LAUNDRY, UTILITY RM AND GARAGE SHALL BE CONTROLLED BY A VACANCY SENSOR. CEC 150.0(k)2J GARAGE 134.64(E) GAR FLR PLAN &ELEVATIONSSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 A2.3DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021 GREEN BUILDING: FINISHES: A.USE LOW-VOC INTERIOR WALL/CEILING PAINTS (<50 GRAMS PER LETTER (GPL) VOCS REGARDLESS OF SHEEN) CGBSC 4.504.2.2 B.USE LOW-VOC COATINGS THAT MEET SCAQMD RULE 1113 (CGBSC 4.504.2.3) PLUMBING: ALL EXISTING NON-COMPLIANT PLUMBING FIXTURES SHALL BE UPGRADED: A.WATER CLOSETS WITH A FLOW RATE IN EXCESS OF 1.6 GPF WILL NEED TO BE REPLACED WITH WATER CLOSETS WITH A MAXIMUM FLOW RATE OF 1.28 GPF. B.SHOWER HEADS WITH A FLOW RATE GREATER THAN 2.5 GPM WILL NEED TO BE REPLACED WITH A MAXIMUM 2.0 GPM SHOWER HEAD. C.LAVATORY AND KITCHEN FAUCETS WITH A FLOW RATE GREATER THAN 2.2 GPM WILL NEED TO BE REPLACED WITH A FAUCET WITH MAXIMUM FLOW RATE OF 1.5 GPM (OR 1.8 GPM FOR KITCHEN FAUCETS). SMOKE DETECTORS: A.SMOKE DETECTOR SYSTEM SHALL BE HARD WIRED AND RECEIVE THEIR PRIMARY POWER FROM BUILDING WIRING, BE INTERCONNECTED TO SOUND SIMULTANEOUSLY AND EQUIPPED WITH BATTERY BACKUP. WIRING SHALL BE PERMANENT AND WITHOUT DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR CURRENT PROTECTION. THE SMOKE ALARM SHALL EMIT A SIGNAL WHEN BATTERIES ARE LOW. B.INSTALL DETECTORS IN EACH BEDROOM, AT EACH CORRIDOR/AREA NEXT TO THE BEDROOM, AT THE TOP OF STAIRS AND EACH STORY AND BASEMENT. C.MULTIPLE SMOKE DETECTORS ARE REQUIRED WHEN CEILING LEVELS/ ELEVATIONS CHANGE OR ARE INTERRUPTED BY ARCHITECTURAL ELEMENTS (CASED OPENINGS, ARCHWAYS, SKYLIGHT WELLS, ETC.) . D.SMOKE DETECTORS SHALL BE LISTED AND COMPLY WITH UL 217 AND BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH NFPA 720 AND MANUFACTURERS INSTRUCTIONS. CARBON MONOXIDE ALARMS: CARBON MONOXIDE ALARMS REQUIRED BY SECTION 420.6.2 SHALL BE INSTALLED AND MAINTAINED IN THE FOLLOWING LOCATIONS: A.OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOM (S). B.ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. C.IN GROUP R-1 OCCUPANCIES; ON THE CEILING OF EVERY SLEEPING UNIT OR OTHER LOCATIONS WITHIN THE SLEEPING UNIT IN COMPLIANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. D.CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH BATTERY BACK-UP. ALARM WIRING SHALL BE DIRECTLY CONNECTED TO THE PERMANENT BUILDING WIRING WITHOUT A DISCONNECTING SWITCH OTHER THAN AS REQUIRED FOR OVERCURRENT PROTECTION. E.WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT, THE ALARM SHALL BE INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. F.CARBON MONOXIDE ALARMS SHALL BE LISTED AND COMPLY WITH UL 2034 AND BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH NFPA 720 AND MANUFACTURERS INSTRUCTIONS. ATTIC AND UNDERFLR INSTALLED FAU: A.UNIT SHALL BE ACCESSIBLE THROUGH AN OPENING AND PASSAGEWAY NOT LESS THAN THE LARGEST COMPONENT OF THE UNIT AND NOT LESS THAN 22"x30" B.THE DISTANCE FROM THE PASSAGEWAY ACCESS TO THE UNIT SHALL NOT EXCEED 20' C.THE WIDTH OF THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE SOLID FLOORING NOT LESS THAN 24" WIDE FROM THE ENTRANCE OPENING TO THE UNIT. D.A LEVEL WORKING PLATFORM NOT LESS THAN 30" BY 30" SHALL BE PROVIDED IN FRONT OF THE SERVICE SIDE OF THE UNIT. E.A PERMANENT 120V RECEPTACLE OUTLET AND A LIGHTING FIXTURE SHALL BE INSTALLED NEAR THE UNIT. THE SWITCH CONTROLLING THE LIGHTING FIXTURE SHALL BE LOCATED AT THE ENTRANCE TO THE PASSAGEWAY. F.PROVIDE 30"x30" MIN ACCESS TO FURNACE IN CRAWL SPACE w/30" x 30" MIN LEVEL SERVICE AREA IN FRONT OF FURNACE IN CRAWL SPACE. FURNACE SHALL NOT BE LOCATED GREATER THAN 20' FROM ACCESS OPENING. PROVIDE SWITCHED LIGHT AND RECEPTICLE AT CRAWL SPACE ENTRANCE G.ATTIC ACCESS THROUGH BEDROOM OR BATHROOM TO HVAC NOT ALLOWED GENERAL ELECTRICAL NOTES: A.RECESS LIGHTS INSTALLED IN INSULATED AREAS SHALL BE IC RATED B.ALL ELECTRICAL EQUIPMENT SHALL BE UL LISTED AND INSTALLED PER LISTING C.ANNULAR SPACES AROUND PIPES, ELECTRICAL CABLES, CONDUITS, ETC. WILL NEED TO BE FILLED TO PREVENT RODENT INTRUSION (4.406.1) D.ALL125 -VOLT, 15 AND 20 AMPERE OUTLETS SHALL BE TAMPER RESISTANT (CEC 406.11) STAIRWAY ILLUMINATION NOTES: A. ALL INTERIOR AND EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH A MEANS TO ILLUMINATE THE STAIRS, INCLUDING THE LANDINGS AND TREADS. B.INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED IN THE IMMEDIATE VICINITY OF EACH LANDING OF THE STAIRWAY. FOR INTERIOR STAIRS THE ARTIFICIAL LIGHT SOURCES SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN 1 FOOT- CANDLE (11 LUX) MEASURED AT THE CENTER OF TREADS AND LANDINGS. C.EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED IN THE IMMEDIATE VICINITY OF THE TOP LANDING OF THE STAIRWAY. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTSIDE GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED IN THE IMMEDIATE VICINITY OF THE BOTTOM LANDING OF THE STAIRWAY. EXTERIOR LIGHTING: ALL OUTDOOR LIGHTING ATTACHED TO THE BUILDING SHALL BE HIGH EFFICACY OR CONTROLLED BY BOTH A MOTION SENSOR AND PHOTO CONTROL PRIOR TO FINAL INSPECTION: COMPLETED CF2R-LTG-OL-E FORM MUST BE PROVIDED TO THE TOWN BUILDING INSPECTOR, PRIOR TO FINAL INSPECTION KITCHEN ELECTRICAL: A.PROVIDE GFCI PROTECTION AT ALL RECEPTACLES SERVING KITCHEN COUNTERTOPS . B.AT EACH KITCHEN AND DINING AREA COUNTER SPACE WIDER THAN 12", LOCATE A RECEPTACLE SO THAT NO POINT ALONG THE COUNTER WALL IS OVER 24" FROM A RECEPTACLE. COUNTERTOP RECEPTACLES REQUIRED WITHIN 24" EACH SIDE OF A BREAK IN THE CONTINUOUS COUNTERTOP SURFACE (SINKS-STOVES). C.REQ'D RECEPTACLES MOUNTED ON THE SIDES OF CABINETS SHALL BE A MAXIMUM OF 12" BELOW THE COUNTERTOP SURFACE WITH A MAXIMUM OF 6" COUNTERTOP OVERHANG. D.PROVIDE AT LEAST TWO (2) 20 AMP CIRCUITS FOR COUNTER RECEPTACLES. E.USE SEPARATE SWITCHING FOR ANY UNDER CABINET LIGHTING (INCLUDING KITCHEN LIGHTING) FROM OTHER LIGHTING SYSTEMS BATHROOM ELECTRICAL: A.PROVIDE 20AMP DEDICATED BRANCH CIRCUIT TO SUPPLY THE BATHROOM OUTLETS. THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS, FANS, ETC. (EXCEPTION-WHERE THE CIRCUIT SUPPLIES A SINGLE BATHROOM, OUTLETS FOR OTHER EQUIPMENT WITHIN THE SAME BATHROOM SHALL BE PERMITTED TO BE SUPPLIED). BATHRM/LAUNDRY VENTILATION NOTES A.EACH BATHROOM SHALL BE MECHANICALLY VENTILATED w/ ENERGY STAR COMPLIANT FANS AND DUCTED TO TERMINATE OUTSIDE THE BLDG (AT LEAST 3' AWAY FROM ANY OPENING). UNLESS FUNCTIONING AS WHOLE HOUSE FAN, FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL (ADJUSTABLE RANGE 50% MIN, - 80% MAX.) B.EXHAUST FANS SHALL HAVE A MIN. OF 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION AND BE ENERGY STAR COMPLIANT AND BE EQUIPPED WITH A HUMIDISTAT AND HUMIDITY CONTROL C.PROVIDE MECHANICAL VENTILATION SYSTEM CAPABLE OF 5 AIR CHANGES/HR AND DISCHARGE TO EXTERIOR. TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS SHALL BE A MINIMUM OF 3 FEET FROM PROPERTY LINES OR ANY OPENINGS INTO THE BUILDING (i.e., DRYERS, BATH AND UTILITY FANS, ETC., MUST BE 3 FEET AWAY FROM DOORS WINDOWS, OPENING SKYLIGHTS OR ATTIC VENTS). BACK DRAFT DAMPER SHALL BE PROVIDED USE SMOOTH METAL D.EXHAUST FANS (EXCLUDES KITCHEN EXHAUST HOOD) SHALL BE SWITCHED SEPARATE FROM LIGHTING (OR UTILIZE A DEVICE WHERE LIGHTING CAN BE TURNED OFF WHILE FAN IS RUNNING) E.DUCT FOR DRYER EXHAUST USE A MAX DUCT LENGTH OF 14' TO OUTSIDE w/ BACKDRAFT DAMPER AND TWO 90 DEGREE ELBOWS AND A MIN. OF 4" DIA. BEDROOM ELECTRICAL: A.ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT SINGLE PHASE, (N)15 AND 20 AMPERE RECEPTACLE OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER(S) B.LIGHTING IN BEDROOMS, STUDY AND EXERCISE ROOMS SHALL BE HIGH EFFICACY OR CONTROLLED BY MANUEL ON MOTION SENSOR OR A DIMMER. C.NO POINT ALONG WALL MORE THAN 6'-0" TO OUTLET IN HABITABLE ROOMS LAUNDRY ELECTRICAL: A.PROVIDE 20AMP DEDICATED BRANCH CIRCUIT TO SUPPLY THE LAUNDRY RECEPTACLE OUTLET. B.MINIMUM 30 AMP DEDICATED CIRCUIT FOR DRYER PER CEC 220.54. HIGH EFFICACY LIGHTING: A.KITCHEN LIGHTING: A MINIMUM OF 50% OF THE TOTAL RATED WATTAGE OF PERMANENTLY INSTALLED LIGHTING SHALL BE HIGH EFFICACY B.BATHROOM LIGHTING: ALL SHALL BE HIGH EFFICACY LIGHTS, ONE SHALL BE CONTROLLED BY OCCUPANCY SENSOR AND ALL OTHER LIGHTING SHALL BE CONTROLLED BY VACANCY SENSORS OR DIMMERS C.GARAGE, LAUNDRY, AND UTILITY ROOMS: LIGHTING INSTALLED IN GARAGES, LAUNDRY, AND UTILITY ROOMS SHALL BE HIGH EFFICACY AND CONTROLLED BY VACANCY SENSORS. D.ALL OTHER ROOMS: LIGHTING INSTALLED IN ALL OTHER ROOMS SHALL BE HIGH EFFICACY AND SHALL BE CONTROLLED BY EITHER DIMMERS OR VACANCY SENSORS. E.HIGH EFFICACY LIGHTING IS NOT REQUIRED IN HALLWAYS OR SMALL CLOSETS OF LESS THAN 70 SF. F.HIGH EFFICACY LIGHTING IS NOT REQUIRED IN ACCESSORY BUILDINGS OF LESS THAN 1000 SF. G.RESIDENTIAL OUTDOOR LIGHTING: OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING SHALL BE HIGH EFFICACY AND BE CONTROLLED BY MANUAL SWITCH THAT DOES NOT OVERRIDE TO ON, AND BY A MOTION SENSOR WITHOUT AN OVERRIDE, AND A PHOTOCONTROL WITHOUT AN OVERRIDE. GARAGE ELECTRICAL: A.PER CEC 210-52(g). PROVIDE AT LEAST ONE GARAGE OUTLET. PER CEC 210-8 GFCI OUTLET IS REQUIRED AT GARAGE B.LIGHT FIXTURES IN GARAGES SHALL BE HIGH EFFICACY AND CONTROLLED BY VACANCY SENSORS EXTERIOR RECEPTICAL: A.PROVIDE EXT. GFCI WATERPROOF RECEPTICLES AT THE FRONT & REAR OF RESIDENCE WITHIN 6'6" OF GRADE. 2016 CALIFORNIA ENERGY CODE NOTES: LOW RISE MANDATORY MEASURES: *LUMINAIRE EFFICACY: ALL INSTALLED LUMINARIES SHALL BE HIGH EFFICACY IN ACCORDANCE WITH TABLE 150.0-A *ALL RECESSED DOWNLIGHT LUMINARIES IN CEILINGS. LUMINARIES RECESSED INTO CEILINGS SHALL MEET ALL OF THE FOLLOWING REQUIREMENTS: **BE LISTED, AS DEFINED IN SECTION 100.1, FOR ZERO CLEARANCE INSULATION CONTACT (IC) BY UNDERWRITERS LABORATORIES OR OTHER NATIONALLY RECOGNIZED TESTING/RATING LAB; AND **HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM E283. AN EXHAUST FAN HOUSING SHALL NOT BE REQUIRED TO BE CERTIFIED AIRTIGHT; AND **BE SEALED WITH A GASKET OR CAULK BETWEEN LUMINAIRE HOUSING AND CEILING AND SHALL HAVE ALL AIR LEAK PATHS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SEALED WITH A GASKET OR CAULK; AND **FOR LUMINARIES WITH HARDWIRED BALLASTS OR DRIVERS, ALLOW BALLAST OR DRIVER MAINTENANCE AND REPLACEMENT TO BE READILY ACCESSIBLE TO BLDG. OCCUPANTS FROM BELOW CEILING WITHOUT REQUIRING THE CUTTING OF HOLES IN THE CEILING; AND **SHALL NOT CONTAIN SCREW BASE SOCKETS; AND **SHALL CONTAIN LIGHT SOURCES THAT COMPLY WITH REFERENCES JOINT APPENDIX JA8, INCLUDING THE ELEVATED TEMPERATURE REQUIREMENTS, AND THAT ARE MARKED "JA8-2016-E" AS SPECIFIED IN REFERENCE JOINT APPENDIX JA8 9/12/18 FROM KRACH DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.Scale: 1/4"=1'-0" EXISTING ELEVATIONS Scale: 1/4"=1'-0" (E) GARAGE FLR PLAN Scale: 1/4"=1'-0" EXISTING ELEVATIONS FRONT REAR LEFT RIGHT (E) SIDING SECTION Scale: 6"=1'-0" 30' MAX HT 30' MAX HT (E) ELEVATIONSSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 A3.1DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021 R806.2 Minimum ven t area The m inimum n et free ventil ating a rea s hall be 1/15 0 of the area o f the vented space. Exc eption : The m inimum n et fr ee ventil atio n a rea s hall be 1/30 0 of the vente d space pro vided one or more of the followin g co nditions are met: 1 . In Climate Zo nes 14 a nd 16, a Class I or II vapo r r etarder is insta lle d o n the warm-i n-win ter side of th e ce iling. 2. No t less tha n 40 percent a nd n ot mor e th an 50 perc ent of the required ventilating area i s provided b y ve ntilators l ocated i n the upper po rtion of the attic or rafter space. U pper ventilators s hall be located not more than 3 feet (914 mm) b elow the ridge or hi ghes t point of the sp ac e, measur ed vertica ll y, with the balance of th e requ ired ventilatio n provid ed by ea ve or corn ic e vents. Wh ere the location of wall or roof frami ng members co nflicts w ith the ins tallation of uppe r v entila tors, installation mo re tha n 3 feet (914 m m) be low th e rid ge or high est poin t of th e sp ac e shall be perm itte d. ATTIC V ENTILATION N OTE: 687 S F / 300 = 2.29 SF = 330 SQ IN AT BO TTOM: 330 S Q IN / 2 = 165 SQ IN RE Q'D 5.5 x 1 4 EAVE VE NT = 4 2 SQ IN. 165 S Q IN REQ'D / 42 SQ IN/V ENT = 3.929 VENT S USE 4 EA 4 x 14 EA VE VENTS (3 EXISTING ) SEE S PEC SHT ON A8.2 PLAN SYMBOL= AT TOP : 330 S Q IN / 2 = 165 SQ IN RE Q'D EYEB ROW VENT = 72 S Q IN 165 S Q IN REQ'D / 72 SQ IN/V ENT = 2.29 ea USE 3 ea ATTIC VEN TS SEE SPE C SHT A8.2 NOTE: A LL AREAS 'NET FR EE FLOW A REA' roof plan 2nd FLR ATTIC AREA 2619 sf 2nd fl r living area 190 plus open flr area 2709 t otal 2nd flr attic 746 vaulted ceilings w/o att ic 2663 sf net 2nd flr at tic ATTIC VENT AREA REQUIRED 2663 sf / 300 = 8.88 sf = 1278 sq in vent required ATTIC VENT AREA REQUIRED AT EAVE 1/2 of 1278 sq in req'd at eave = 639 sq in 167 LF of eave w/ 2ea 2" dia holes/ l f = 334 holes 334 holes x 1^2 x 3.14 = 1049 sq in 1049 sq in > 639 req'd OK ATTIC VENT AREA REQUIRED AT TOP 1/2 of 1278 sq in req'd at TOP = 639 sq in use 4 ea eyebrow vents @ 170 sq in vent area ea 4ea x 170 sq in ea = 680 sq in > 639 req'd OK all areas "f ree fl ow area"DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.Scale: 1/4"=1'-0" EXISTING ELEVATIONS FRONT REAR LEFT RIGHT (E) SIDING IS ALTERNATING 7" & 2" COURSES OF PAINTED WOOD SHINGLES SEE SHT P1 FOR PICTURE OF FRONT DR TO BE REUSED 30' MAX HT 30' MAX HT PROP'D ELEVATIONSSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 A3.2DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.Scale: 1/4"=1'-0" PROPOSED ELEVATIONS FRONT REAR LEFT RIGHT (N) EXTERIOR SIDING TO MATCH (E) ALTERNATING 7" & 2" COURSES OF PAINTED WOOD SHINGLES ALL (N) EXTERIOR FIN ISHES TO MATCH EXISTING SEE SHT P1 FOR PICTURE OF FRONT DR TO BE REUSE D 8' ADDITION 8' ADDITION NEW DECK ACROSS REAR OF HOUSE AND ADDITION8' 1st FLR ADDITION IN FOREGROUND NEW DECK ACROSS REAR OF HOUSE AND ADDITION MAKE ALL FRONT COLUMN S 9 1/4" SQNO CH ANGES 16'9"29' (E) HOUSE AND GARAGEPICTURESSHEET: SCALE: DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 P1DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.(E) RESIDENCE PICTURES FRONTREARRIGHT FRONTREARLEFT (E) GARAGE PICT URES This Page Intentionally Left Blank