Item 3 - Addendum and Attachment 5
PREPARED BY: SEAN MULLIN, AICP
Associate Planner
110 E. Main Street Los Gatos, CA 95030 ● 408-354-6874
www.losgatosca.gov
TOWN OF LOS GATOS
HISTORIC PRESERVATION
COMMITTEE REPORT
MEETING DATE: 05/26/2021 ITEM NO: 3 ADDENDUM
DATE: May 25, 2021
TO: Historic Preservation Committee
FROM: Joel Paulson, Community Development Director
SUBJECT: Preliminary Review of a Request for Construction of Exterior Alterations and
an Addition to an Existing Pre-1941 Single-Family Residence on Property
Zoned R-1:8 Located at 320 Johnson Avenue. APN 529-39-070. Property
Owner: Steve and Gina Sprich. Applicant: Steven Plyler, De Mattei
Construction. Project Planner: Sean Mullin.
DISCUSSION:
The applicant has revised the dimensions of the front porch columns proposed to replace the
existing four-inch square columns. The previous plans proposed six-inch square columns
(Attachment 4). The applicant now proposes nine and one-quarter inch square columns
(Attachment 5).
ATTACHMENTS:
Previously received with the May 26, 2021 Staff Report:
1. 1990 Bloomfield Survey
2. Sanborn Map Exhibit
3. Section 3.9, Residential Design Guidelines
4. Development Plans
Received with this Addendum:
5. Revised Development Plans
This Page
Intentionally
Left Blank
E / LE / LN
Cross Section 13
A. A SIGN SHALL BE POSTED STATING THAT THE TOWN OF WOODSIDE CONSTRUCTIONHOURS ARE LIMITED TO MONDAY THROUGH FRIDAY BETWEEN 7:30 A.M. AND 5:30 P.M.;SATURDAY BETWEEN 8:00 A.M. AND 1:00 P.M.;SUNDAY; NO CONSTRUCTION ALLOWED.THERE SHALL BE NO DELIVERIES OR RUNNING OF EQUIPMENT PRIOR TO THESE TIMES.FAILURE TO COMPLY WITH TOWN CONSTRUCTION HOURS MAY RESULT IN A STOPWORK NOTICE.B. AT NO TIME SHALL THE STREET BE CLOSED OR BLOCKED. FLAGMEN SHALL BE USEDAT ALL TIMES WHEN DELIVERIES OR CONSTRUCTION RESTRICT ANY PORTION OF THERIGHT OF WAY.C. ON-STREET PARKING IS NOT ALLOWED. ALL CONSTRUCTION PARKING MUST BE ON-SITE.D. ALL PROTECTIVE FENCING SHALL BE MAINTAINED IN PLACE THROUGHOUT THEDURATION OF CONSTRUCTION.E. NO DEMOLITION OR CONSTRUCTION MAY COMMENCE UNTIL THE PROTECTIVEFENCING HAS BEEN INSTALLED, INSPECTED, AND APPROVED BY THE PORTOLA VALLEYPUBLIC WORKS INSPECTOR.134.6444.01
42.34110PG&E
CABLE
TV
SSCO W/M
25' FSB 8' SSB8' SSB20' RS
B
9"dia
T
R
E
E
TO R
E
M
AI
N
9"dia
T
R
E
E
TO R
E
M
AI
N
6" di
a
T
R
E
E
TO R
E
M
AI
N
4"dia
T
R
E
E
S
TO B
E
REM
O
V
E
D
70 CONCRETE WALK
227 SF
FIRST FLR
ADDITION
(ANGLE
DOUBLE
HATCHED)
7 SF FIRST FLR
ADDITION
(ANGLE DOUBLE
HATCHED)
(E) 1020 SF
2ND FLR
(SHADED)
21 SF FIRST FLR
AREA REMOVED
(CROSS ANGLE
HATCHED)3' ACCSRY SSBIF 5' SEPARATION(E) 1300 SF 1ST FLR
WIDE ANLGE HATCH
(E) PORCH
(E)
POTTING
SHED
PROPOSED
381 SF DECK8' SSBPROP'D 64 SF
PORCH
EXTENSION
(N) FPL
320 JO
H
N
S
O
N
A
V
E
364 SF (E) GARAGE
(HATCHED LINE)
23'10" (N) SIDE
SETBACK
4" di
a
T
R
E
E
T
O
BE R
E
M
O
V
E
D TITLE SHEETCITY OF SARATOGA:
CONSTRUCTION WORK HOURS:
MONDAY - FRIDAY 7:30AM - 6:00PM
SATURDAYS 9:00AM - 5:00PM
SUNDAYS AND WEEKDAY HOLIDAYS PROHIBITED
SITE MANAGEMENT:
A. SITE SHALL BE MAINTAINED CLEAN AT ALL TIMES AND CONSTRUCTION DEBRIS
HAULED OFF ON A REGULAR BASIS.
B. "BEST MANAGEMENT PRACTICE" SHALL BE IN PLACE AND MAINTAINED DURING
THIS PROJECT FOR PROTECTION OF ANY POLLUTANTS ENTERING THE EXISTING
STORMWATER SYSTEM.
COVERSHEET NOTES FOR
SARATOGA
RESPONSES TO PLAN CHECK COMMENTS
SHEET:
SCALE:
DRAWN BY:DRAWINGS PROVIDED BY:09/18/15HPC SET 5/24/2021 T1DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABY DATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021
Historic Preservation (HPC) | The Los Gatos CA Official Site!
SHEET INDEX
PROJECT DIRECTORY
SCOPE OF WORK:
SCOPE OF WORK: 230 JOHNSON AVE
NET ADDITION OF 213 SF TO FIRST FLOOR OF EXISTING 2342 SF 2 STORY
RESIDENCE
RE-COMPARTMENTALIZE SOME OF FIRST FLOOR
ADD 64 SF EXTENSION OF FRONT PORCH
ADD 381 SF NEW REAR DECK
MOVE FPL LOCATION TO LEFT SIDE TOWARD REAR
N Scale: 1/8"=1'-0"
SITE/ROOF PLAN
PROJECT
LOCATION
ToDo:ToDo:
1. PLACE HOLDER, BECAUSE IT WON'T
FORMAT WITHOUT IT.
SHEET INDEX
T1 TITLE SHEET
A2.1 (E) FLOOR PLANS
A2.2 PROPOSED FLOOR PLANS
A2.3 (E) GAR FLR PLAN & ELEVATIONS
A3.1 (E) ELEVATIONS
A3.2 PROP'D ELEVATIONS
P1 (E) HOUSE AND GARAGE PICTURES The drawings, plans, models, designs, specifications, reports, photographs, computer print-outs in association with the design development are intended for the use by the De Mattei Construction Inc. This work is intended solely for Owner. The contracted drawings are madeavailable for informational purposes only in relation to (Project). Drawings may not be copied, reproduced or distributed in anyway without written consent from De Mattei Construction Inc. De Mattei Construction Inc. cannot be held liable for any unauthorized use of the drawingsCONSTRUCTION SHALL CONFORM TO:
2016 California Building Code
2016 California Residential Code
2016 California Plumbing Code
2016 California Mechanical Code
2016 California Electrical Code
2016 Energy Code
2016 Green Building Code
2016 California Fire Code
2016 California Reference Standards Code
PROPERTY OWNER:
Steven and Gina Sprich
320 Johnson Ave, LG, Ca 95030
stevesprich@gmail.com
gina.sprich@gmail.com
DESIGNER/CONTRACTOR:
Steven W Plyler, (408) 390-5971
steve@demattei.com
DE MATTEI CONSTRUCTION, INC.
1794 the Alameda
San Jose, Calif 95126
(408) 295-7516
PROPERTY OWNER:
John and Carol Traub
(408) 230-9568, (408) 472-5648
1741 University Ave, SJ, Ca 95126
4x ENGINEERING, INC
4340 Stevenscreek Blvd Suite #240
San Jose, Calif 95129
(408) 642-5464
DESIGNER/CONTRACTOR:
Steven W Plyler, (408) 390-5971
steve@demattei.com
DE MATTEI CONSTRUCTION, INC.
1794 the Alameda
San Jose, Calif 95126
(408) 295-7516DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.SPRICH RESIDENCE REMODEL
ASSESSOR'S PARCEL MAP
RENDERING w/ PROPOSED ADDITION
ATTACHMENT 5
E / LE / LE / LE / LE / L4x4 Post
4x4 Post
4x4 Post
4x4 Post4x4 Post
4x4 Post4x4 Post
4x4 Post4x4 Post
4x4 Post
10'-11 11/16"5'-8 1/2"26'-4 15/16"16'-0 13/16"6'-0 1/2"14'-0 1/2"40'-0 11/16"12'-4 3/16"17'-9 1/8"5'-8 1/2"6'-1"2'-8 7/8"46'-1 11/16"35'-9 13/16"
18'-4 1/2"18'-0 1/2"9'-11"3'-4"8'-5 1/2"21'-4 1/2"A.A SIGN SHALL BE POSTED STATING THAT THE TOWN OF WOODSIDE CONSTRUCTIONHOURS ARE LIMITED TO MONDAY THROUGH FRIDAY BETWEEN 7:30 A.M. AND 5:30 P.M.;SATURDAY BETWEEN 8:00 A.M. AND 1:00 P.M.;SUNDAY; NO CONSTRUCTION ALLOWED.THERE SHALL BE NO DELIVERIES OR RUNNING OF EQUIPMENT PRIOR TO THESE TIMES.FAILURE TO COMPLY WITH TOWN CONSTRUCTION HOURS MAY RESULT IN A STOPWORK NOTICE. B.AT NO TIME SHALL THE STREET BE CLOSED OR BLOCKED. FLAGMEN SHALL BE USEDAT ALL TIMES WHEN DELIVERIES OR CONSTRUCTION RESTRICT ANY PORTION OF THERIGHT OF WAY. C.ON-STREET PARKING IS NOT ALLOWED. ALL CONSTRUCTION PARKING MUST BE ON-SITE. D.ALL PROTECTIVE FENCING SHALL BE MAINTAINED IN PLACE THROUGHOUT THEDURATION OF CONSTRUCTION.E.NO DEMOLITION OR CONSTRUCTION MAY COMMENCE UNTIL THE PROTECTIVEFENCING HAS BEEN INSTALLED, INSPECTED, AND APPROVED BY THE PORTOLA VALLEYPUBLIC WORKS INSPECTOR.
AT LEAST ONE FIXTURE IN EACH
BATHRM, LAUNDRY, UTILITY RM AND
GARAGE SHALL BE CONTROLLED BY A
VACANCY SENSOR. CEC 150.0(k)2J
LI VIN G ROOM
DIN ING ROOM
KITCHEN
PORCH
GARAGE
15' FSB 8' SSB3' ACCSRY SSBIF 5' SEPARATION4 " d ia T R E E S
T O B E
R E M O V E D
BEDROOM
BEDROOM
BEDROOM
BATH
CLOSET
9 "d ia T R E E
T O R E M A IN
9 "d ia T R E E
T O R E M A IN
4 " d ia T R E E
T O B E
R E M O V E D
6 " d ia T R E E
T O R E M A IN
(E)
POTTING
SHED
UP DN20'-5 3/4"34'-0 7/16"6'-8 11/16"6'-0 1/4"15'-4 1/8"8'-0 1/2"6'-0 1/4"22'-3 1/4"9'-7 9/16"11'-9 3/16"48 46
100
BEDROOM
M. CLOSET
M. BEDROOM
BATH
LAUNDRYCLOSETLINENBALCONY
HALL
DN
OPEN AREA
A.A SIGN SHALL BE POSTED STATING THAT THE TOWN OF WOODSIDE CONSTRUCTIONHOURS ARE LIMITED TO MONDAY THROUGH FRIDAY BETWEEN 7:30 A.M. AND 5:30 P.M.;SATURDAY BETWEEN 8:00 A.M. AND 1:00 P.M.;SUNDAY; NO CONSTRUCTION ALLOWED.THERE SHALL BE NO DELIVERIES OR RUNNING OF EQUIPMENT PRIOR TO THESE TIMES.FAILURE TO COMPLY WITH TOWN CONSTRUCTION HOURS MAY RESULT IN A STOPWORK NOTICE. B.AT NO TIME SHALL THE STREET BE CLOSED OR BLOCKED. FLAGMEN SHALL BE USEDAT ALL TIMES WHEN DELIVERIES OR CONSTRUCTION RESTRICT ANY PORTION OF THERIGHT OF WAY. C.ON-STREET PARKING IS NOT ALLOWED. ALL CONSTRUCTION PARKING MUST BE ON-SITE. D.ALL PROTECTIVE FENCING SHALL BE MAINTAINED IN PLACE THROUGHOUT THEDURATION OF CONSTRUCTION.E.NO DEMOLITION OR CONSTRUCTION MAY COMMENCE UNTIL THE PROTECTIVEFENCING HAS BEEN INSTALLED, INSPECTED, AND APPROVED BY THE PORTOLA VALLEYPUBLIC WORKS INSPECTOR.
KEY
WALL TO B E
DEMOLISHE D
(E) WALL (E) FLOOR PLANSSHEET:
SCALE:
DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 A2.1DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021
X LINEAL FEET OF EAVE W/2X RAFTERS @ 16" O.C.:
X'/16" = ±X AVAILABLE BLOCKS
NEW UNDER FLOOR AREA TO BE VENTED =
XXX SQ.FT.
NEW ATTIC AREA TO BE VENTED = XXX SQ.FT.
XXX/150(144) = XXX SQ.IN. NFVA REQUIRED
EXISTING FLOOR AND DEMO PLANS
XXX/150(144) = XXX SQ.IN. NFVA REQUIRED
1 FLOOR VENT UNIT:
13.5" X 7.5" = 101.25 SQ.IN NFVA
1 EAVE BLOCKING VENT UNIT:
14" x 5.5" = 77 SQ.IN NFVA
X FLOOR VENTS PROVIDED, DISTRIBUTED EVENLY:
(X) x XXX SQ.IN = XXX SQ.IN. NFVA
XXX SQ.IN. NFVA PROVIDED
> XXX SQ.IN. NFVA REQUIRED
X EAVE VENTS PROVIDED, DISTRIBUTED EVENLY:
(X) x X SQ.IN. = XXX SQ.IN. NFVA
XXX SQ.IN. NFVA PROVIDED
> XXX SQ.IN. NFVA REQUIRED
LEGEND:
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW INTERIOR CONSTRUCTION; 2x4 WD. STUD,
1/2" GYP. BD. EACH SIDE
NEW EXTERIOR CONSTRUCTION; SEE 5/A3.2
NEW 1-HR FIRE RATED WALL; 2x4 WD. STUD, 5/8"
TYPE "X" GYP. BD. EACH SIDE. SEE PLAN FOR
LOCATIONS.
LEGEND:
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
LEGEND:
EXISTING CONSTRUCTION
NEW CONSTRUCTION
PLUMBING:
A.ALL NEW TOILETS SHALL HAVE AN EFFECTIVE FLUSH VOLUME NOT TO EXCEED 1.28
GALLONS PER FLUSH.
B.LAVATORY FAUCETS SHALL NOT EXCEED 1.2 GPM AT 60 PSI (MIN. SHALL NOT BE
LESS THAN 0.8 GPM AT 20 PSI).
C.ALL NEW SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF 2.0 GALLONS
PER MINUTE AT 80 PSI.
D.ALL NEW KITCHEN FAUCETS SHALL HAVE A MAXIMUM FLOW RATE OF 1.8 GALLONS
PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE
FLOW ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE
AT 60 PSI AND MUST DEFAULT TO A MAXIMUM FLOW RATE OF 1.8 GALLONS PER
MINUTE AT 60 PSI.
(TYP) STAIR NOTES
STAIR GENERAL NOTE:
-MAX RISE 7 3/4", MIN RUN 10", FOR TAPERED TREADS
MIN. TREAD WIDTH REQUIRED 12" FROM NARROW END
WHICH SHALL NOT BE LESS THAN 6" AT ANY POINT
-MIN. HEADROOM IS 6'8"
-MIN. CLEAR WIDTH IS 36"
-HAND RAILS SHALL BE 34" TO 38" ABOVE TREADS AND RETURN TO WALLS
PROTECT UNDERSTAIR WITH 1 HR CONSTRUCTION, 5/8" TYPE "X" SHEETROCK INSIDE
WALLS AND CEILING
HANDRAILS SHALL HAVE 1-1/4 - 2 INCH GRIPPABLE CROSS SECTION, NO SHARP
CORNERS, EXTEND CONTINUOUSLY FROM TOP TO BOTTOM RISER, AND TERMINATE
AT NEWEL POSTS OR RETURN TO WALLS. (TYP)
HANDRAILS:
"EXCEPTION #3 STAIRWAYS HAVING LESS THAN FOUR RISERS AND SERVING ON
INDIVIDUAL DWELLING UNIT IN GROUP R, ......NEED NOT HAVE HANDRAILS"
SPACE RAIL MEMBERS SUCH THAT A 4" dia SPHERE CANNOT PASS THROUGH
GUARDRAILS, HEIGHT:
"THE TOP OF GUARDRAILS SHALL NOT BE LESS THAN 42 INCHES IN HEIGHT.
GUARDRAILS:
" WHERE REQUIRED. ....LANDINGS,.. BALCONIES OR PORCHES,WHICH ARE MORE
THAN 30 INCHES ABOVE GRADE OR FLOOR BELOW,......SHALL BE PROTECTED BY A
GUARD RAIL."
LANDING:
REQ'D 36" DEEP (IN THE DIRECTION OF TRAVEL) x WIDTH OF DOOR MAXIMUM DROP
FROM TOP OF THRESHOLD IS 7.75" FOR IN SWINGING, 1/2" FOR OUT SWINGING
DOORS, & 3/4" FOR SLIDING DOORS PER CBC 1008.1.5 - 1008.1.6
(TYP) ACCESS NOTES:
A. EGRESS: (FOR NEW CONSTRUCTION AREAS) PER CBC 1026.1-1026.5. SLEEPING
ROOMS MUST HAVE AN OPERABLE WINDOW OR EXTERIOR DOOR FOR EMERGENCY
MEANS OF EGRESS WHICH OPENS DIRECTLY ONTO A PUBLIC STREET, ALLEY, YARD
OR EXTERIOR COURT. PROVIDE SILL HEIGHT NOT OVER 44" ABOVE FLOOR, 5.7 SF OF
OPERABLE AREA, 24" NET CLEAR OPENING HEIGHT, 20" NET CLEAR OPENING WIDTH.
B. ATTIC ACCESS: MIN 22" x 30" PER SECTION R807 CRC 2016
C. UNDERFLOOR ACCESS: 18" x 24" MIN.
WATER HEATER TO BE INSTALLED ON 18" TALL STAND. USE 1 1/2" x 16ga STRAP w/ 3/8"
dia X 3" LONG LAG AT POINTS WITH IN THE UPPER AND LOWER ONE THIRD OF ITS
VERTICAL DIMENSION, THE LOWER ANCHOR STRAP LOCATED TO MAINTAIN A
MINIMUM DISTANCE OF 4 INCHES ABOVE THE CONTROLS.
MIN RECOVERY RATE OF WATER HEATER EQUIVALENT TO NOT LESS THAN THE FIRST
HOUR RATING OF 67 GALLONS
(TYP) GARAGE NOTES:
A. PER TABLE 3-B UBC 302.4-GARAGE REQUIRES 1 HOUR OCCUPANCY SEPARATION
CONSTRUCTION ON GARAGE SIDE ONLY WHERE GARAGE ADJOINS THE REST OF THE
BUILDING. 5/8" TYPE X SHEETROCK ALL WALLS AND SURFACES BETWEEN GARAGE
AND HOUSE (TYP)B. PER UBC 302.4, USE A 1 3/4" SOLID WOOD SELF-CLOSING DR w/ A
FIRE RATING OF NOT LESS THAN 20 MIN.
C. PER CBC 302.2 AND 302.4.3, FOR HABITABLE SPACES ABOVE GARAGE USE, 5/8"
TYPE "X" GYP BD SHALL BE APPLIED TO GARAGE CEILING AND SUPPORTING
MEMBERS (eg BEAMS COLUMNS AND BEARING WALLS).
D. PER CBC 302.2 AND 302.4.3, FOR HABITABLE SPACES ABOVE GARAGE SPACING OF
RAFTERS/CEILING JOISTS SHALL BE A MAXIMUM OF 16" o.c. (PER CBC TABLE 7-C) OR
USE 2 LAYERS 5/8" TYPE "X" GYP BD APPLIED TO FRAMING @24" o.c.
(TYP) WATER HEATER NOTES:
PROVIDE 1 SF/2 KBTU COMBUSTION AIR AT
BOTH WITHIN 12" OF FLOOR AND 12" OF CEILING
BATHROOM:
A.WATER CLOSETS SHALL BE LOCATED IN SPACES NOT LESS THAN 30" IN WIDTH
AND 24" IN FRONT.
B.WATER RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED WHERE THERE
WILL BE DIRECT EXPOSURE TO WATER. CRC 702.5.7.1
C.BACKER FOR SHOWER AND TUB SHOWER WALLS TO BE FIBER-CEMENT, FIBER
REINFORCED CEMENTITIOUS BACKER UNITS, GLASS MAT GYPSUM BACKERS OR
FIBER-REINFORCED GYPSUM BACKERS TO A MIN. HEIGHT OF 72" ABOVE THE
FLOOR.
D.USE 2X8 WOODEN BACKING IN ALL BATHROOM WALLS AT WATER CLOSET
SHOWER AND BATHTUB, LOCATED AT 34" FROM FLOOR TO CENTER OF THE
BACKING SUITABLE FOR THE ADDITION OF GRAB BARS.
E.DOORS AND PANELS OF TUB AND SHOWER ENCLOSURES SHALL BE FULLY
TEMPERED LAMINATED SAFETY GLASS OR APPROVED PLASTIC.
F.SHOWER COMPARTMENTS SHALL HAVE MIN INTERIOR FLOOR AREA OF 1024 SQ IN
AND ABLE TO CONTAIN A 30" DIA. CIRCLE.
G.SHOWER AND TUB SHOWER COMBINATION IN ALL BUILDING SHALL BE PROVIDED
WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE
THERMOSTATIC MIXING VALVE TYPE.
(TYP) WINDOW & DOOR NOTES:A. NEW WINDOWS SHALL HAVE A MAXIMUM U FACTOR OF 0.27 & SHADING
COEFFICIENT SGHC OF 0.20
B. NEW DOORS SHALL HAVE A MAXIMUM U FACTOR OF 0.27 & SHADING COEFFICIENT
SGHC OF 0.20
C. PROVIDE WEATHERSTRIPPING BETWEEN UNHEATED STORAGE OR ATTIC SAME AS
EXTERIOR DOORS (TYP)
D. FOR LIGHT REQUIREMENT PROVIDE A WINDOW AREA OF NOT LESS THAT 10% OF
FLOOR AREA NOR LESS THAT 10 SF, FOR VENTILATION PROVIDE AN OPERABLE
WINDOW AREA OF NOT LESS THAN 5% OF FLOOR AREA NOR LESS THAN 5 SF.
E. WINDOW IN SHOWER LESS THAN 70" ABOVE THE DRAIN OUTLET TO BE TYPE NOT
ADVERSELY AFFECTED BY MOISTURE
(TYP) RECYCLE NOTES:
MINIMUM OF 65% OF THE NON-HAZARDOUS CONSTRUCTION AND DEMOLITION DEBRIS
WILL BE RECYCLED AND/OR SALVAGED FOR REUSE IN ACCORDANCE WITH SECTIONS
4,408.2, 4.408.3, OR 4.408.4. CGBSC SECTION 4.408.L
(TYP) HVAC NOTES:
A. PROVIDE 1 SF/2 KBTU COMBUSTION AIR AT BOTH
WITHIN 12" OF FLOOR AND 12" OF CEILING
B. PROVIDE 30"x30" MIN ACCESS TO FURNACE IN ATTIC w/30" x 30" MIN LEVEL SERVICE
AREA IN FRONT OF FURNACE . FURNACE SHALL NOT BE LOCATED GREATER THAN 20'
FROM ACCESS OPENING. PROVIDE SWITCHED LIGHT AND RECEPTACLE AT ATTIC
SPACE ENTRANCE. PROVIDE 24" WIDE PLATFORM PATH TO FAU
C. PROVIDE 30"x30" MIN ACCESS TO FURNACE IN CRAWL SPACE w/30" x 30" MIN LEVEL
SERVICE AREA IN FRONT OF FURNACE IN CRAWL SPACE. FURNACE SHALL NOT BE
LOCATED GREATER THAN 20' FROM ACCESS OPENING. PROVIDE SWITCHED LIGHT
AND RECEPTICLE AT CRAWL SPACE ENTRANCE
D. ATTIC ACCESS THROUGH BEDROOM OR BATHROOM TO HVAC NOT ALLOWED
E. CENTRAL HEATING BOILERS AND FURNACES.
LOCATION: CENTRAL HEATING FURNACE AND LOW PRESSURE BOILER INSTALLATIONS
IN BEDROOMS OR BATHROOMS SHALL COMPLY WITH ONE OF THE FOLLOWING [NFPA
54:9.3.1]
(1)CENTRAL HEATING FURNACES AND LOW-PRESSURE BOILERS MAY BE INSTALLED
IN A CLOSET LOCATED IN THE BEDROOM OR BATHROOM, PROVIDED THE CLOSET
IS EQUIPPED WITH A LISTED, GASKETED DOOR ASSEMBLY AND A LISTED SELF-
CLOSING DEVICE. THE SELF-CLOSING DOOR ASSEMBLY SHALL BE THE
REQUIREMENTS OF CODE. ALL COMBUSTION AIR FOR SUCH INSTALLATIONS SHALL
BE OBTAINED FROM THE OUTDOORS. THE CLOSET SHALL BE FOR THE EXCLUSIVE
USE OF THE CENTRAL HEATING FURNACE OR LOW-PRESSURE BOILER.
(2)CENTRAL HEATING FURNACES AND LOW-PRESSURE BOILERS SHALL BE OF THE
DIRECT-VENT TYPE. SELF-CLOSING DOORS. SELF-CLOSING DOORS SHALL SWING
EASILY AND FREELY AND SHALL BE EQUIPPED WITH A SELF-CLOSING DEVICE TO
CAUSE THE DOOR TO CLOSE AND LATCH EACH TIME IS OPENED. THE CLOSING
MECHANISM SHALL NOT HAVE A HOLD-OPEN FEATURE.
GASKETING: GASKETING ON GASKET DOORS OR FRAMES SHALL BE FURNISHED ONLY
IN ACCORDANCE WITH THE PUBLISHED LISTING OF THE DOOR, FRAME, OR
GASKETING MATERIAL MANUFACTURER. EXCEPTION: WHERE ACCEPTABLE TO THE
AUTHORITY HAVING JURISDICTION, GASKETING OF NONCOMBUSTIBLE OR LIMITED
COMBUSTIBLE MATERIAL (SEE NFPA 220, STANDARD ON TYPES OF BUILDING
CONSTRUCTION) SHALL BE PERMITTED TO BE APPLIED TO THE FRAME, PROVIDED
CLOSING AND LATCHING OF THE DOOR ARE NOT INHIBITED.
DISHWASHER NOTE:
NO DOMESTIC DISHWASHING MACHINE SHALL BE DIRECTLY CONNECTED TO A
DRAINAGE SYSTEM OR FOOD WASTE DISPOSER WITHOUT THE USE OF AN
APPROVED DISHWASHER AIR GAP FITTING ON THE DISCHARGE SIDE OF THE
DISHWASHING MACHINE. LISTED AIRGAPS SHALL BE INSTALLED WITH THE FLOOD-
LEVEL (FL) MARKING AT OR ABOVE THE FLOOD LEVEL OF THE SINK OR DRAIN BOARD,
WHICHEVER IS HIGHER. CPC SEC. 807.3
INSULATION NOTE:
NOTE ON THE PLANS THAT FOR ALL REMODELS, INSULATION MEETING THE
MANDATORY FEATURE REQUIREMENTS IN THE CAL IFORNIA ENERGY CODE SHALL BE
INSTALLED AT CEILINGS, WALLS, FLOORS AND WATER PIPES, WHEN THESE AREAS
ARE EXPOSED DURING REMODELING. SCC CODE 12.10.250
BATHRM/LAUNDRY VENTILATION NOTES
A.EACH BATHROOM SHALL BE MECHANICALLY VENTILATED w/ ENERGY STAR
COMPLIANT FANS AND DUCTED TO TERMINATE OUTSIDE THE BLDG (AT LEAST 3'
AWAY FROM ANY OPENING). UNLESS FUNCTIONING AS WHOLE HOUSE FAN, FANS
MUST BE CONTROLLED BY A HUMIDITY CONTROL (ADJUSTABLE RANGE 50% MIN, -
80% MAX.)
B.EXHAUST FANS SHALL HAVE A MIN. OF 50 CFM FOR INTERMITTENT VENTILATION OR
20 CFM FOR CONTINUOUS VENTILATION AND BE ENERGY STAR COMPLIANT AND BE
EQUIPPED WITH A HUMIDISTAT AND HUMIDITY CONTROL
C.PROVIDE MECHANICAL VENTILATION SYSTEM CAPABLE OF 5 AIR CHANGES/HR AND
DISCHARGE TO EXTERIOR. TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS
SHALL BE A MINIMUM OF 3 FEET FROM PROPERTY LINES OR ANY OPENINGS INTO
THE BUILDING (i.e., DRYERS, BATH AND UTILITY FANS, ETC., MUST BE 3 FEET AWAY
FROM DOORS WINDOWS, OPENING SKYLIGHTS OR ATTIC VENTS). BACK DRAFT
DAMPER SHALL BE PROVIDED USE SMOOTH METAL
D.EXHAUST FANS (EXCLUDES KITCHEN EXHAUST HOOD) SHALL BE SWITCHED
SEPARATE FROM LIGHTING (OR UTILIZE A DEVICE WHERE LIGHTING CAN BE
TURNED OFF WHILE FAN IS RUNNING)
E.DUCT FOR DRYER EXHAUST USE A MAX DUCT LENGTH OF 14' TO OUTSIDE w/
BACKDRAFT DAMPER AND TWO 90 DEGREE ELBOWS AND A MIN. OF 4" DIA.
R311.7.6 Landings for stairways. There shall be a floor or landing at the top and
bottom of each stairway. The minimum width perpendicular to the direction of travel
shall be no less than the width of the flight served…
Exception: A floor or landing is not required at the top of an interior flight of stairs,
including stairs in an enclosed garage, provided a door does not swing over the
stairs.DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.FIRST FLOOR PLANSECOND FLOOR PLAN
Scale: 1/4"=1'-0"
UP
E / LE / LE / LE / LE / LS2
A3.2
20'-1 5/8"
5'-4"9'-8"8'-0"
10'-10"5'-8"2'-5"
5'-7 1/2"
3'-7 11/16"5'-0"5'-7"7'-0"13'-5"10'-10"17'-6"2'-5"6'-4 1/2"7'-3 1/2"5'-7"5'-6 3/4"12'-0 3/16"7'-9 1/4"11'-1 1/2"2'-3"2'-6"2'-6"1'-0"1'-0"6'-1"18'-4 1/2"18'-0 1/2"9'-11"3'-4"8'-5 1/2"21'-4 1/2"6'-0 1/4"46'-1 11/16"BEDROOM
FAM ILY ROOM
48" PICKET FENCE
2.5, 5 OC
PORCH
B EDROOM
KITCHEN
PANTRY
EXE RCISE R OOM
BATH
POW DER
9'-6"
APPROX.
5'+
CONCRETE WALK
HALL
PROPOSED DEC K
(E)
POTTING
SHED
ADDITION
(E) GARAGE
REPL (E) 4x4 POSTS w/ 9 1/4" SQ POSTS
(N) 9 1/4" SQ
PORCH POST
RELOCATE
(E) FRONT DR
RELOCATED
(E) WINDOW
(N)
WINDOW
BEDROOM
M. CLOSET
M. BEDROOM
BATH
LINENBALCONY
CLOSETOPEN AREALAUNDRYHALL
PATCH
WHERE
WALLS
REM'D
PATCH
WHERE 1/2
WALLS
REM'D
(N) WALL
K EY
(E) WALL PROPOSED FLOORPLANSSHEET:
SCALE:
DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 A2.2DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.FIRST FLOOR PLANSECOND FLOOR PLAN
Scale: 1/4"=1'-0"
PROPOSED FLOOR PLANS
9"A.A SIGN SHALL BE POSTED STATING THAT THE TOWN OF WOODSIDE CONSTRUCTIONHOURS ARE LIMITED TO MONDAY THROUGH FRIDAY BETWEEN 7:30 A.M. AND 5:30 P.M.;SATURDAY BETWEEN 8:00 A.M. AND 1:00 P.M.;SUNDAY; NO CONSTRUCTION ALLOWED.THERE SHALL BE NO DELIVERIES OR RUNNING OF EQUIPMENT PRIOR TO THESE TIMES.FAILURE TO COMPLY WITH TOWN CONSTRUCTION HOURS MAY RESULT IN A STOPWORK NOTICE. B.AT NO TIME SHALL THE STREET BE CLOSED OR BLOCKED. FLAGMEN SHALL BE USEDAT ALL TIMES WHEN DELIVERIES OR CONSTRUCTION RESTRICT ANY PORTION OF THERIGHT OF WAY. C.ON-STREET PARKING IS NOT ALLOWED. ALL CONSTRUCTION PARKING MUST BE ON-SITE. D.ALL PROTECTIVE FENCING SHALL BE MAINTAINED IN PLACE THROUGHOUT THEDURATION OF CONSTRUCTION.E.NO DEMOLITION OR CONSTRUCTION MAY COMMENCE UNTIL THE PROTECTIVEFENCING HAS BEEN INSTALLED, INSPECTED, AND APPROVED BY THE PORTOLA VALLEYPUBLIC WORKS INSPECTOR.
KEY
WA LL TO BE
DEMOLISHE D
(E) WALL
18'-4 1/2"18'-0 1/2"9'-11"3'-4"8'-5 1/2"21'-4 1/2"A.A SIGN SHALL BE POSTED STATING THAT THE TOWN OF WOODSIDE CONSTRUCTIONHOURS ARE LIMITED TO MONDAY THROUGH FRIDAY BETWEEN 7:30 A.M. AND 5:30 P.M.;SATURDAY BETWEEN 8:00 A.M. AND 1:00 P.M.;SUNDAY; NO CONSTRUCTION ALLOWED.THERE SHALL BE NO DELIVERIES OR RUNNING OF EQUIPMENT PRIOR TO THESE TIMES.FAILURE TO COMPLY WITH TOWN CONSTRUCTION HOURS MAY RESULT IN A STOPWORK NOTICE. B.AT NO TIME SHALL THE STREET BE CLOSED OR BLOCKED. FLAGMEN SHALL BE USEDAT ALL TIMES WHEN DELIVERIES OR CONSTRUCTION RESTRICT ANY PORTION OF THERIGHT OF WAY. C.ON-STREET PARKING IS NOT ALLOWED. ALL CONSTRUCTION PARKING MUST BE ON-SITE. D.ALL PROTECTIVE FENCING SHALL BE MAINTAINED IN PLACE THROUGHOUT THEDURATION OF CONSTRUCTION.E.NO DEMOLITION OR CONSTRUCTION MAY COMMENCE UNTIL THE PROTECTIVEFENCING HAS BEEN INSTALLED, INSPECTED, AND APPROVED BY THE PORTOLA VALLEYPUBLIC WORKS INSPECTOR.
AT LEAST ONE FIXTURE IN EACH
BATHRM, LAUNDRY, UTILITY RM AND
GARAGE SHALL BE CONTROLLED BY A
VACANCY SENSOR. CEC 150.0(k)2J
GARAGE
134.64(E) GAR FLR PLAN &ELEVATIONSSHEET:
SCALE:
DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 A2.3DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021
GREEN BUILDING:
FINISHES:
A.USE LOW-VOC INTERIOR WALL/CEILING PAINTS (<50 GRAMS PER LETTER (GPL)
VOCS REGARDLESS OF SHEEN) CGBSC 4.504.2.2
B.USE LOW-VOC COATINGS THAT MEET SCAQMD RULE 1113 (CGBSC 4.504.2.3)
PLUMBING:
ALL EXISTING NON-COMPLIANT PLUMBING FIXTURES SHALL BE UPGRADED:
A.WATER CLOSETS WITH A FLOW RATE IN EXCESS OF 1.6 GPF WILL NEED TO BE
REPLACED WITH WATER CLOSETS WITH A MAXIMUM FLOW RATE OF 1.28 GPF.
B.SHOWER HEADS WITH A FLOW RATE GREATER THAN 2.5 GPM WILL NEED TO BE
REPLACED WITH A MAXIMUM 2.0 GPM SHOWER HEAD.
C.LAVATORY AND KITCHEN FAUCETS WITH A FLOW RATE GREATER THAN 2.2 GPM
WILL NEED TO BE REPLACED WITH A FAUCET WITH MAXIMUM FLOW RATE OF
1.5 GPM (OR 1.8 GPM FOR KITCHEN FAUCETS).
SMOKE DETECTORS:
A.SMOKE DETECTOR SYSTEM SHALL BE HARD WIRED AND RECEIVE THEIR PRIMARY
POWER FROM BUILDING WIRING, BE INTERCONNECTED TO SOUND
SIMULTANEOUSLY AND EQUIPPED WITH BATTERY BACKUP. WIRING SHALL BE
PERMANENT AND WITHOUT DISCONNECTING SWITCH OTHER THAN THOSE
REQUIRED FOR CURRENT PROTECTION. THE SMOKE ALARM SHALL EMIT A SIGNAL
WHEN BATTERIES ARE LOW.
B.INSTALL DETECTORS IN EACH BEDROOM, AT EACH CORRIDOR/AREA NEXT TO THE
BEDROOM, AT THE TOP OF STAIRS AND EACH STORY AND BASEMENT.
C.MULTIPLE SMOKE DETECTORS ARE REQUIRED WHEN CEILING LEVELS/
ELEVATIONS CHANGE OR ARE INTERRUPTED BY ARCHITECTURAL ELEMENTS
(CASED OPENINGS, ARCHWAYS, SKYLIGHT WELLS, ETC.) .
D.SMOKE DETECTORS SHALL BE LISTED AND COMPLY WITH UL 217 AND BE
INSTALLED AND MAINTAINED IN ACCORDANCE WITH NFPA 720 AND
MANUFACTURERS INSTRUCTIONS.
CARBON MONOXIDE ALARMS:
CARBON MONOXIDE ALARMS REQUIRED BY SECTION 420.6.2 SHALL BE INSTALLED AND
MAINTAINED IN THE FOLLOWING LOCATIONS:
A.OUTSIDE OF EACH SEPARATE DWELLING UNIT SLEEPING AREA IN THE IMMEDIATE
VICINITY OF THE BEDROOM (S).
B.ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS.
C.IN GROUP R-1 OCCUPANCIES; ON THE CEILING OF EVERY SLEEPING UNIT OR
OTHER LOCATIONS WITHIN THE SLEEPING UNIT IN COMPLIANCE WITH THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
D.CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE
BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL
SOURCE AND SHALL BE EQUIPPED WITH BATTERY BACK-UP. ALARM WIRING SHALL
BE DIRECTLY CONNECTED TO THE PERMANENT BUILDING WIRING WITHOUT A
DISCONNECTING SWITCH OTHER THAN AS REQUIRED FOR OVERCURRENT
PROTECTION.
E.WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIRED TO BE
INSTALLED WITHIN THE DWELLING UNIT OR WITHIN A SLEEPING UNIT, THE ALARM
SHALL BE INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONE ALARM
SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT.
F.CARBON MONOXIDE ALARMS SHALL BE LISTED AND COMPLY WITH UL 2034 AND BE
INSTALLED AND MAINTAINED IN ACCORDANCE WITH NFPA 720 AND
MANUFACTURERS INSTRUCTIONS.
ATTIC AND UNDERFLR INSTALLED FAU:
A.UNIT SHALL BE ACCESSIBLE THROUGH AN OPENING AND PASSAGEWAY NOT LESS
THAN THE LARGEST COMPONENT OF THE UNIT AND NOT LESS THAN 22"x30"
B.THE DISTANCE FROM THE PASSAGEWAY ACCESS TO THE UNIT SHALL NOT
EXCEED 20'
C.THE WIDTH OF THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE
SOLID FLOORING NOT LESS THAN 24" WIDE FROM THE ENTRANCE OPENING TO
THE UNIT.
D.A LEVEL WORKING PLATFORM NOT LESS THAN 30" BY 30" SHALL BE PROVIDED IN
FRONT OF THE SERVICE SIDE OF THE UNIT.
E.A PERMANENT 120V RECEPTACLE OUTLET AND A LIGHTING FIXTURE SHALL BE
INSTALLED NEAR THE UNIT. THE SWITCH CONTROLLING THE LIGHTING FIXTURE
SHALL BE LOCATED AT THE ENTRANCE TO THE PASSAGEWAY.
F.PROVIDE 30"x30" MIN ACCESS TO FURNACE IN CRAWL SPACE w/30" x 30" MIN LEVEL
SERVICE AREA IN FRONT OF FURNACE IN CRAWL SPACE. FURNACE SHALL NOT BE
LOCATED GREATER THAN 20' FROM ACCESS OPENING. PROVIDE SWITCHED LIGHT
AND RECEPTICLE AT CRAWL SPACE ENTRANCE
G.ATTIC ACCESS THROUGH BEDROOM OR BATHROOM TO HVAC NOT ALLOWED
GENERAL ELECTRICAL NOTES:
A.RECESS LIGHTS INSTALLED IN INSULATED AREAS SHALL BE IC RATED
B.ALL ELECTRICAL EQUIPMENT SHALL BE UL LISTED AND INSTALLED PER LISTING
C.ANNULAR SPACES AROUND PIPES, ELECTRICAL CABLES, CONDUITS, ETC. WILL
NEED TO BE FILLED TO PREVENT RODENT INTRUSION (4.406.1)
D.ALL125 -VOLT, 15 AND 20 AMPERE OUTLETS SHALL BE TAMPER RESISTANT (CEC
406.11)
STAIRWAY ILLUMINATION NOTES:
A. ALL INTERIOR AND EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH A MEANS TO
ILLUMINATE THE STAIRS, INCLUDING THE LANDINGS AND TREADS.
B.INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE
LOCATED IN THE IMMEDIATE VICINITY OF EACH LANDING OF THE STAIRWAY. FOR
INTERIOR STAIRS THE ARTIFICIAL LIGHT SOURCES SHALL BE CAPABLE OF
ILLUMINATING TREADS AND LANDINGS TO LEVELS NOT LESS THAN 1 FOOT-
CANDLE (11 LUX) MEASURED AT THE CENTER OF TREADS AND LANDINGS.
C.EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE
LOCATED IN THE IMMEDIATE VICINITY OF THE TOP LANDING OF THE STAIRWAY.
EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTSIDE
GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED
IN THE IMMEDIATE VICINITY OF THE BOTTOM LANDING OF THE STAIRWAY.
EXTERIOR LIGHTING:
ALL OUTDOOR LIGHTING ATTACHED TO THE BUILDING SHALL BE HIGH EFFICACY OR
CONTROLLED BY BOTH A MOTION SENSOR AND PHOTO CONTROL
PRIOR TO FINAL INSPECTION:
COMPLETED CF2R-LTG-OL-E FORM MUST BE PROVIDED TO THE TOWN BUILDING
INSPECTOR, PRIOR TO FINAL INSPECTION
KITCHEN ELECTRICAL:
A.PROVIDE GFCI PROTECTION AT ALL RECEPTACLES SERVING KITCHEN
COUNTERTOPS .
B.AT EACH KITCHEN AND DINING AREA COUNTER SPACE WIDER THAN 12", LOCATE A
RECEPTACLE SO THAT NO POINT ALONG THE COUNTER WALL IS OVER 24" FROM A
RECEPTACLE. COUNTERTOP RECEPTACLES REQUIRED WITHIN 24" EACH SIDE OF
A BREAK IN THE CONTINUOUS COUNTERTOP SURFACE (SINKS-STOVES).
C.REQ'D RECEPTACLES MOUNTED ON THE SIDES OF CABINETS SHALL BE A
MAXIMUM OF 12" BELOW THE COUNTERTOP SURFACE WITH A MAXIMUM OF 6"
COUNTERTOP OVERHANG.
D.PROVIDE AT LEAST TWO (2) 20 AMP CIRCUITS FOR COUNTER RECEPTACLES.
E.USE SEPARATE SWITCHING FOR ANY UNDER CABINET LIGHTING (INCLUDING KITCHEN
LIGHTING) FROM OTHER LIGHTING SYSTEMS
BATHROOM ELECTRICAL:
A.PROVIDE 20AMP DEDICATED BRANCH CIRCUIT TO SUPPLY THE BATHROOM
OUTLETS. THIS CIRCUIT CANNOT SUPPLY ANY OTHER RECEPTACLES, LIGHTS,
FANS, ETC. (EXCEPTION-WHERE THE CIRCUIT SUPPLIES A SINGLE BATHROOM,
OUTLETS FOR OTHER EQUIPMENT WITHIN THE SAME BATHROOM SHALL BE
PERMITTED TO BE SUPPLIED).
BATHRM/LAUNDRY VENTILATION NOTES
A.EACH BATHROOM SHALL BE MECHANICALLY VENTILATED w/ ENERGY STAR
COMPLIANT FANS AND DUCTED TO TERMINATE OUTSIDE THE BLDG (AT LEAST 3'
AWAY FROM ANY OPENING). UNLESS FUNCTIONING AS WHOLE HOUSE FAN, FANS
MUST BE CONTROLLED BY A HUMIDITY CONTROL (ADJUSTABLE RANGE 50% MIN, -
80% MAX.)
B.EXHAUST FANS SHALL HAVE A MIN. OF 50 CFM FOR INTERMITTENT VENTILATION OR
20 CFM FOR CONTINUOUS VENTILATION AND BE ENERGY STAR COMPLIANT AND BE
EQUIPPED WITH A HUMIDISTAT AND HUMIDITY CONTROL
C.PROVIDE MECHANICAL VENTILATION SYSTEM CAPABLE OF 5 AIR CHANGES/HR AND
DISCHARGE TO EXTERIOR. TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS
SHALL BE A MINIMUM OF 3 FEET FROM PROPERTY LINES OR ANY OPENINGS INTO
THE BUILDING (i.e., DRYERS, BATH AND UTILITY FANS, ETC., MUST BE 3 FEET AWAY
FROM DOORS WINDOWS, OPENING SKYLIGHTS OR ATTIC VENTS). BACK DRAFT
DAMPER SHALL BE PROVIDED USE SMOOTH METAL
D.EXHAUST FANS (EXCLUDES KITCHEN EXHAUST HOOD) SHALL BE SWITCHED
SEPARATE FROM LIGHTING (OR UTILIZE A DEVICE WHERE LIGHTING CAN BE
TURNED OFF WHILE FAN IS RUNNING)
E.DUCT FOR DRYER EXHAUST USE A MAX DUCT LENGTH OF 14' TO OUTSIDE w/
BACKDRAFT DAMPER AND TWO 90 DEGREE ELBOWS AND A MIN. OF 4" DIA.
BEDROOM ELECTRICAL:
A.ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT SINGLE PHASE, (N)15 AND 20
AMPERE RECEPTACLE OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER(S)
B.LIGHTING IN BEDROOMS, STUDY AND EXERCISE ROOMS SHALL BE HIGH EFFICACY
OR CONTROLLED BY MANUEL ON MOTION SENSOR OR A DIMMER.
C.NO POINT ALONG WALL MORE THAN 6'-0" TO OUTLET IN HABITABLE ROOMS
LAUNDRY ELECTRICAL:
A.PROVIDE 20AMP DEDICATED BRANCH CIRCUIT TO SUPPLY THE LAUNDRY
RECEPTACLE OUTLET.
B.MINIMUM 30 AMP DEDICATED CIRCUIT FOR DRYER PER CEC 220.54.
HIGH EFFICACY LIGHTING:
A.KITCHEN LIGHTING: A MINIMUM OF 50% OF THE TOTAL RATED WATTAGE OF
PERMANENTLY INSTALLED LIGHTING SHALL BE HIGH EFFICACY
B.BATHROOM LIGHTING: ALL SHALL BE HIGH EFFICACY LIGHTS, ONE SHALL BE
CONTROLLED BY OCCUPANCY SENSOR AND ALL OTHER LIGHTING SHALL BE
CONTROLLED BY VACANCY SENSORS OR DIMMERS
C.GARAGE, LAUNDRY, AND UTILITY ROOMS: LIGHTING INSTALLED IN GARAGES,
LAUNDRY, AND UTILITY ROOMS SHALL BE HIGH EFFICACY AND CONTROLLED BY
VACANCY SENSORS.
D.ALL OTHER ROOMS: LIGHTING INSTALLED IN ALL OTHER ROOMS SHALL BE HIGH
EFFICACY AND SHALL BE CONTROLLED BY EITHER DIMMERS OR VACANCY
SENSORS.
E.HIGH EFFICACY LIGHTING IS NOT REQUIRED IN HALLWAYS OR SMALL CLOSETS OF
LESS THAN 70 SF.
F.HIGH EFFICACY LIGHTING IS NOT REQUIRED IN ACCESSORY BUILDINGS OF LESS
THAN 1000 SF.
G.RESIDENTIAL OUTDOOR LIGHTING: OUTDOOR LIGHTING PERMANENTLY MOUNTED
TO A RESIDENTIAL BUILDING SHALL BE HIGH EFFICACY AND BE CONTROLLED BY
MANUAL SWITCH THAT DOES NOT OVERRIDE TO ON, AND BY A MOTION SENSOR
WITHOUT AN OVERRIDE, AND A PHOTOCONTROL WITHOUT AN OVERRIDE.
GARAGE ELECTRICAL:
A.PER CEC 210-52(g). PROVIDE AT LEAST ONE GARAGE OUTLET. PER CEC 210-8 GFCI
OUTLET IS REQUIRED AT GARAGE
B.LIGHT FIXTURES IN GARAGES SHALL BE HIGH EFFICACY AND CONTROLLED BY
VACANCY SENSORS
EXTERIOR RECEPTICAL:
A.PROVIDE EXT. GFCI WATERPROOF RECEPTICLES AT THE FRONT & REAR OF
RESIDENCE WITHIN 6'6" OF GRADE.
2016 CALIFORNIA ENERGY CODE NOTES:
LOW RISE MANDATORY MEASURES:
*LUMINAIRE EFFICACY: ALL INSTALLED LUMINARIES SHALL BE HIGH EFFICACY IN
ACCORDANCE WITH TABLE 150.0-A
*ALL RECESSED DOWNLIGHT LUMINARIES IN CEILINGS. LUMINARIES RECESSED INTO
CEILINGS SHALL MEET ALL OF THE FOLLOWING REQUIREMENTS:
**BE LISTED, AS DEFINED IN SECTION 100.1, FOR ZERO CLEARANCE INSULATION
CONTACT (IC) BY UNDERWRITERS LABORATORIES OR OTHER NATIONALLY
RECOGNIZED TESTING/RATING LAB; AND
**HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH AIR LEAKAGE LESS
THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN ACCORDANCE WITH ASTM E283. AN
EXHAUST FAN HOUSING SHALL NOT BE REQUIRED TO BE CERTIFIED AIRTIGHT; AND
**BE SEALED WITH A GASKET OR CAULK BETWEEN LUMINAIRE HOUSING AND CEILING
AND SHALL HAVE ALL AIR LEAK PATHS BETWEEN CONDITIONED AND
UNCONDITIONED SPACES SEALED WITH A GASKET OR CAULK; AND
**FOR LUMINARIES WITH HARDWIRED BALLASTS OR DRIVERS, ALLOW BALLAST OR
DRIVER MAINTENANCE AND REPLACEMENT TO BE READILY ACCESSIBLE TO BLDG.
OCCUPANTS FROM BELOW CEILING WITHOUT REQUIRING THE CUTTING OF HOLES IN
THE CEILING; AND
**SHALL NOT CONTAIN SCREW BASE SOCKETS; AND
**SHALL CONTAIN LIGHT SOURCES THAT COMPLY WITH REFERENCES JOINT APPENDIX
JA8, INCLUDING THE ELEVATED TEMPERATURE REQUIREMENTS, AND THAT ARE
MARKED "JA8-2016-E" AS SPECIFIED IN REFERENCE JOINT APPENDIX JA8
9/12/18 FROM KRACH
DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.Scale: 1/4"=1'-0"
EXISTING ELEVATIONS
Scale: 1/4"=1'-0"
(E) GARAGE FLR PLAN
Scale: 1/4"=1'-0"
EXISTING ELEVATIONS
FRONT
REAR
LEFT
RIGHT
(E) SIDING SECTION
Scale: 6"=1'-0"
30' MAX HT
30' MAX HT (E) ELEVATIONSSHEET:
SCALE:
DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 A3.1DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021
R806.2 Minimum ven t area
The m inimum n et free ventil ating a rea s hall be 1/15 0 of the area o f the vented
space.
Exc eption : The m inimum n et fr ee ventil atio n a rea s hall be 1/30 0 of the vente d
space pro vided one or more of the followin g co nditions are met:
1 . In Climate Zo nes 14 a nd 16, a Class I or II vapo r r etarder is insta lle d o n the
warm-i n-win ter side of th e ce iling.
2. No t less tha n 40 percent a nd n ot mor e th an 50 perc ent of the required ventilating
area i s provided b y ve ntilators l ocated i n the upper po rtion of the attic or rafter
space. U pper ventilators s hall be located not more than 3 feet (914 mm) b elow the
ridge or hi ghes t point of the sp ac e, measur ed vertica ll y, with the balance of th e
requ ired ventilatio n provid ed by ea ve or corn ic e vents. Wh ere the location of wall
or roof frami ng members co nflicts w ith the ins tallation of uppe r v entila tors,
installation mo re tha n 3 feet (914 m m) be low th e rid ge or high est poin t of th e sp ac e
shall be perm itte d.
ATTIC V ENTILATION N OTE:
687 S F / 300 = 2.29 SF = 330 SQ IN
AT BO TTOM:
330 S Q IN / 2 = 165 SQ IN RE Q'D
5.5 x 1 4 EAVE VE NT = 4 2 SQ IN.
165 S Q IN REQ'D / 42 SQ IN/V ENT = 3.929 VENT S
USE 4 EA 4 x 14 EA VE VENTS (3 EXISTING )
SEE S PEC SHT ON A8.2
PLAN SYMBOL=
AT TOP :
330 S Q IN / 2 = 165 SQ IN RE Q'D
EYEB ROW VENT = 72 S Q IN
165 S Q IN REQ'D / 72 SQ IN/V ENT = 2.29 ea
USE 3 ea ATTIC VEN TS SEE SPE C SHT A8.2
NOTE: A LL AREAS 'NET FR EE FLOW A REA'
roof plan
2nd FLR ATTIC AREA
2619 sf 2nd fl r living area
190 plus open flr area
2709 t otal 2nd flr attic
746 vaulted ceilings w/o att ic
2663 sf net 2nd flr at tic
ATTIC VENT AREA REQUIRED
2663 sf / 300 = 8.88 sf = 1278 sq in vent required
ATTIC VENT AREA REQUIRED AT EAVE
1/2 of 1278 sq in req'd at eave = 639 sq in
167 LF of eave w/ 2ea 2" dia holes/ l f = 334 holes
334 holes x 1^2 x 3.14 = 1049 sq in
1049 sq in > 639 req'd OK
ATTIC VENT AREA REQUIRED AT TOP
1/2 of 1278 sq in req'd at TOP = 639 sq in
use 4 ea eyebrow vents @ 170 sq in vent area ea
4ea x 170 sq in ea = 680 sq in > 639 req'd OK
all areas "f ree fl ow area"DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.Scale: 1/4"=1'-0"
EXISTING ELEVATIONS
FRONT
REAR
LEFT
RIGHT
(E) SIDING IS
ALTERNATING 7" & 2"
COURSES OF PAINTED
WOOD SHINGLES
SEE SHT P1 FOR
PICTURE OF FRONT DR
TO BE REUSED
30' MAX HT
30' MAX HT
PROP'D ELEVATIONSSHEET:
SCALE:
DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 A3.2DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.Scale: 1/4"=1'-0"
PROPOSED ELEVATIONS
FRONT
REAR
LEFT
RIGHT
(N) EXTERIOR SIDING TO
MATCH (E) ALTERNATING
7" & 2" COURSES OF
PAINTED WOOD
SHINGLES
ALL (N) EXTERIOR
FIN ISHES TO MATCH
EXISTING
SEE SHT P1 FOR
PICTURE OF FRONT DR
TO BE REUSE D
8' ADDITION
8' ADDITION
NEW DECK ACROSS REAR OF HOUSE AND ADDITION8' 1st FLR ADDITION IN FOREGROUND
NEW DECK ACROSS REAR
OF HOUSE AND ADDITION
MAKE ALL FRONT
COLUMN S 9 1/4" SQNO CH ANGES 16'9"29'
(E) HOUSE AND GARAGEPICTURESSHEET:
SCALE:
DRAWN BY:DRAWINGS PROVIDED BY:HPC SET 5/24/2021 P1DESCRIPTIONDATE:PROJECT DESCRIPTION:SPRICH RESIDENCE320 JOHNSON AVELOS GATOS, CALIFORNIABYDATENO.SHEET TITLE:DeMattei Construction, Inc.DeMattei Construction, Inc.1794 The Alameda, San Jose,CA. 95126P: (408) 295-7516F: (408) 286-6589LIC.# B-4784555/24/2021DISCLAIMER:THIS DOCUMENT CONTAINSCONFIDENTIAL AND PROPRIETARYINFORMATION THAT IS INTENDED FORTHE USE OF "De Mattei Construction Inc."DRAWINGS SHOULD NOT BEREPRODUCED OR DIVULGED, INWHOLE OR IN PART, WITHOUT WRITTENAUTHORIZATION FROM "De MatteiConstruction Inc." "De Mattei ConstructionInc." CANNOT BE HELD LIABLE IN THEEVENT THE DRAWINGS AREREPRODUCED OR DIVULGED WITHOUTWRITTEN AUTHORIZATION.(E) RESIDENCE PICTURES
FRONTREARRIGHT
FRONTREARLEFT
(E) GARAGE PICT URES
This Page
Intentionally
Left Blank