Loading...
2020-005 - Denying an Appeal of the Decision of the Planning Commission, 15365 Santella Court, LGRESOLUTION 2020-005 RESOLUTION OF THE TOWN COUNCIL OF THE TOWN OF LOS GATOS DENYING AN APPEAL OF THE DECISION OF THE PLANNING COMMISSION APPROVING A REQUEST FOR CONSTRUCTION OF A NEW SINGLE-FAMILY RESIDENCE AND REMOVAL OF LARGE PROTECTED TREES ON A VACANT PROPERTY ZONED HR-2 1/2:PD. APN 527-09-036 ARCHITECTURE AND SITE APPLICATION: S-18-052 PROPERTY LOCATION: 15365 SANTELLA COURT APPELLANT: DAVID WEISSMAN APPLICANT: HARI SRIPADANNA PROPERTY OWNER: CHRISTIAN AND HELLEN OLGAARD WHEREAS, on January 8, 2020, the Planning Commission held a public hearing and considered a request for construction of a new single-family residence and removal of large protected trees on a vacant property zoned HR-2 %2:PD. The Planning Commission approved the Architecture and Site application subject to conditions of approval; and WHEREAS, on January 17, 2020, the appellant filed an appeal of the decision of the Planning Commission approving the request for construction of a new single-family residence and removal of large protected trees on a vacant property zoned HR-2 %2:PD; and WHEREAS, this matter came before the Town Council for public hearing on March 3, 2020, and was regularly noticed in conformance with State and Town law; and WHEREAS, the Town Council received testimony and documentary evidence from the appellant and all interested persons who wished to testify or submit documents. Town Council considered all testimony and materials submitted, including the record of the Planning Commission proceedings and the packet of material contained in the Council Agenda Report for their meeting on March 3, 2020, along with any and all subsequent reports and materials prepared concerning this application. NOW, THEREFORE, BE IT RESOLVED: 1. The appeal of the decision of the Planning Commission approving a request for construction of a new single-family residence and removal of large protected trees on vacant property zoned HR-2 %:PD is denied and the application is approved; 1 of 19 Resolution 2020-005 March 3, 2020 2. The Town Council hereby adopts all findings, considerations, and conditions of approval set forth in the documents attached as Exhibits A and B; and 3. The decision constitutes a final administrative decision pursuant to Code of Civil Procedure section 1094.6 as adopted by section 1.10.085 of the Town Code of the Town of Los Gatos. Any application forjudicial relief from this decision must be sought within the time limits and pursuant to the procedures established by Code of Civil Procedure section 1094.6, or such shorter time as required by state and federal Law. PASSED AND ADOPTED at a regular meeting of the Town Council of the Town of Los Gatos, California, held on the 3rd day of March 2020, by the following vote: COUNCIL MEMBERS: AYES: Rob Rennie, Marico Sayoc, Barbara Spector, Mayor Marcia Jensen NAYS: None ABSENT: None ABSTAIN: None SIGNED: MAYOR OF THE TOWN OF LOS GATOS LOS GATOS, CALIFORNIA DATE: (7 ATTEST: TNL-� TOWN CLERK OF THE TOWN OF LOS GATOS LOS GATOS, CALIFORNIA DATE: _q , o'2USL0 2of19 Resolution 2020-005 March 3, 2020 TOWN COUNCIL -March 3, 2020 REQUIRED FINDINGS & CONSIDERATIONS FOR: 15365 Santella Court Architecture and Site Application S-18-052 Requesting approval for construction of a new single-family residence and removal of large protected trees on a vacant property zoned HR-2 1/2:PD. APN 527-09-036. PROPERTY OWNER: Christian and Hellen Olgaard APPLICANT: Hari Sripadanna FINDINGS Required findings for CEQA: An Environmental Impact Report (EIR) was prepared for the Planned Development and was certified by the Town Council on December 19, 2005. Required technical reviews (arborist, architect and geotechnical) have been completed for the project and no further environmental analysis is required for this application. Compliance with Hillside Development Standards and Guidelines (HDS&G): The project is in compliance with the HDS&G. Compliance with Hillside Specific Plan The project is in compliance with the Hillside Specific Plan in that it is a single-family residence being developed on an existing parcel. The proposed development is consistent with the development criteria included in the Specific Plan. Compliance with the approved Planned Development The project is in compliance with the approved Planned Development (Ordinance 2237). CONSIDERATIONS: Considerations in review of Architecture & Site applications: ■ As required by Section 29.20.150 of the Town Code, the considerations in review of an Architecture and Site application were all made in reviewing this project. EXHIBIT A 3of19 Resolution 2020-005 March 3, 2020 TOWN COUNCIL - March 3, 2020 CONDITIONS OF APPROVAL 15365 Santella Court Architecture and Site Application 5-18-052 Requesting approval for construction of a new single-family residence and removal of large protected trees on a vacant property zoned HR-2 1/2:PD. APN 527-09-036. PROPERTY OWNER: Christian and Hellen Olgaard APPLICANT: Hari Sripadanna TO THE SATISFACTION OF THE DIRECTOR OF COMMUNITY DEVELOPMENT: Planning Division 1. APPROVAL: This application shall be completed in accordance with all of the conditions of approval listed below and in substantial compliance with the plans approved and noted as received by the Town on November 15, 2019. Any changes or modifications to the approved plans shall be approved by the Community Development Director, the Development Review Committee, the Planning Commission, or Town Council, depending on the scope of the changes. 2. EXPIRATION: The approval will expire two years from the approval date pursuant to Section 29.20.320 of the Town Code, unless the approval has been vested. 3. OUTDOOR LIGHTING: Exterior lighting shall be kept to a minimum, and shall be down directed fixtures that will not reflect or encroach onto adjacent properties. No flood lights shall be used unless it can be demonstrated that they are needed for safety or security. The lighting plan shall be reviewed during building plan check. 4. EXTERIOR COLOR: The exterior colors of the house shall not exceed an average light reflectivity value of 30 and shall blend with the natural vegetation in conformance with the approved PD Ordinance 2237. 5. LRV DEED RESTRICTION: Prior to the issuance of a building permit, a deed restriction shall be recorded by the applicant with the Santa Clara County Recorder's Office that requires all exterior colors to be maintained in conformance with the approved PD Ordinance. 6. GENERAL: All existing trees shown on the plan and trees required to remain or to be planted are specific subjects of approval of this plan, and must remain on the site. 7. MAINTENANCE AGREEMENT: Following the issuance of a certificate of occupancy, the property owner shall execute a five-year maintenance agreement with the Town that the property owner agrees to protect and maintain the trees shown to remain on the approved plans, trees planted as part of the tree replacement requirements, and guarantees that said trees will always be in a healthy condition during the term of the maintenance agreement. EXHIBIT B 4of19 Resolution 2020-005 March 3, 2020 8. TREE DEED RESTRICTION: Prior to issuance of a building permit, a deed restriction shall be recorded by the applicant with the Santa Clara County Recorder's Office that identifies the on -site trees that were used to provide screening in the visibility analysis and requires their replacement if they die or are removed. 9. TREE REMOVAL PERMIT: A Tree Removal Permit shall be obtained for any trees to be removed, prior to the issuance of a building or grading permit. 10. ARBORIST REQUIREMENTS: The developer shall implement, at their cost, all recommendations made by Richard Gessner, identified in the Arborist report, dated as received November 29, 2018, and the supplemental Arborist report, dated as received August 20, 2019, respectively, on file in the Community Development Department. A Compliance Memorandum shall be prepared by the applicant and submitted with the building permit application detailing how the recommendations have or will be addressed. These recommendations must be incorporated in the building permit plans, and completed prior to issuance of a building permit where applicable. 11. TREE FENCING: Protective tree fencing shall be placed at the drip line of existing trees and shall remain through all phases of construction. Fencing shall be six -foot -high cyclone attached to two-inch diameter steel posts drive 18 inches into the ground and spaced no further than 10 feet apart. Include a tree protection fencing plan with the construction plans. 12. REPLACEMENT TREES: New trees shall be planted to mitigate the loss of trees being removed. The number of trees and size of replacement trees shall be determined using the canopy replacement table in the Town Code. Town Code requires a minimum 24- inch box size replacement tree. New trees shall be double staked with rubber ties and shall be planted prior to final inspection and issuance of occupancy permits. 13. LANDSCAPE PLAN: The final landscape plan shall comply with the Hillside Development Standards and Guidelines criteria for planting (ornamental planting shall be confined to areas within 30 feet of the house, inclusive of decks, patios and driveway). 14. WATER EFFICIENCY LANDSCAPE ORDINANCE: The final landscape plan, including landscape and irrigation plans and calculations, shall meet the Town of Los Gatos Water Conservation Ordinance or the State Water Efficient Landscape Ordinance, whichever is more restrictive. The final landscape plan shall be reviewed by the Town's consultant prior to issuance of building permits. A review fee based on the current fee schedule adopted by the Town Council is required when working landscape and irrigation plans are submitted for review. 15. BMP IN -LIEU FEE: A Below Market Price (BMP) in -lieu fee (6% of the building valuation as determined by the Building Official) shall be paid by the developer prior to issuance of an occupancy permit for the new residence. 16. FRONT YARD LANDSCAPE: Prior to issuance of a Certificate of Occupancy the front yard must be landscaped. 17. STORY POLES: The story poles on the project site shall be removed within 30 days of approval of the Architecture & Site application. 18. TOWN INDEMNITY: Applicants are notified that Town Code Section 1.10.115 requires that any applicant who receives a permit or entitlement from the Town shall defend, indemnify, and hold harmless the Town and its officials in any action brought by a third 5of19 Resolution 2020-005 March 3, 2020 party to overturn, set aside, or void the permit or entitlement. This requirement is a condition of approval of all such permits and entitlements whether or not expressly set forth in the approval, and may be secured to the satisfaction of the Town Attorney. 19. COMPLIANCE MEMORANDUM: A memorandum shall be prepared and submitted with the building plans detailing how the Conditions of Approval will be addressed. Building Division 20. PERMITS REQUIRED: A Building Permit is required for the construction of the new single- family residence and attached garage. Additional Building permits will be required for all detached structures such as swimming pools and retaining walls supporting a surcharge. 21. APPLICABLE CODES: The current codes, as amended and adopted by the Town of Los Gatos as of January 1, 2017, are the 2016 California Building Standards Code, California Code of Regulations Title 24, Parts 1-12. These codes are applicable on Building Applications up to December 20, 2019. Effective January 1, 2020 the 2019 California Building Standard Code, California Code of Regulations Title 24, Parts 1-12, as amended by the Town of Los Gatos, will be applicable. 22. CONDITIONS OF APPROVAL: The Conditions of Approval must be blue -lined in full on the cover sheet of the construction plans. A Compliance Memorandum shall be prepared and submitted with the building permit application detailing how the Conditions of Approval will be addressed. 23. BUILDING & SUITE NUMBERS: Submit requests for new building addresses to the Building Division prior to submitting for the building permit application process. 24. SIZE OF PLANS: Submit four sets of construction plans, minimum size 24" x 36", maximum size 30" x 42". 25. SOILS REPORT: A Soils Report, prepared to the satisfaction of the Building Official, containing foundation and retaining wall design recommendations, shall be submitted with the Building Permit Application. This report shall be prepared by a licensed Civil Engineer specializing in soils mechanics. 26. SHORING: Shoring plans and calculations will be required for all excavations which exceed five (5) feet in depth or which remove lateral support from any existing building, adjacent property, or the public right-of-way. Shoring plans and calculations shall be prepared by a California licensed engineer and shall confirm to the Cal/OSHA regulations. 27. FOUNDATION INSPECTIONS: A pad certificate prepared by a licensed civil engineer or land surveyor shall be submitted to the project Building Inspector at foundation inspection. This certificate shall certify compliance with the recommendations as specified in the Soils Report, and that the building pad elevations and on -site retaining wall locations and elevations have been prepared according to the approved plans. Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered Civil Engineer for the following items: a. Building pad elevation b. Finish floor elevation C. Foundation corner locations 6of19 Resolution 2020-005 March 3, 2020 d. Retaining wall(s) locations and elevations 28. TITLE 24 ENERGY COMPLIANCE: All required California Title 24 Energy Compliance Forms must be blue -lined (sticky -backed), i.e. directly printed, onto a plan sheet. 29. TOWN RESIDENTIAL ACCESSIBILITY STANDARDS: New residential units shall be designed with adaptability features for single-family residences per Town Resolution 1994-61: a. Wood backing (2" x 8" minimum) shall be provided in all bathroom walls, at water closets, showers, and bathtubs, located 34 inches from the floor to the center of the backing, suitable for the installation of grab bars if needed in the future. b. All passage doors shall be at least 32-inch doors on the accessible floor level. C. The primary entrance door shall be a 36-inch-wide door including a 5'x 5' level landing, no more than 1 inch out of plane with the immediate interior floor level and with an 18 inch clearance at interior strike edge. d. A door buzzer, bell or chime shall be hard wired at primary entrance. 30. BACKWATER VALVE: The scope of this project may require the installation of a sanitary sewer backwater valve per Town Ordinance 6.50.025. Please provide information on the plans if a backwater valve is required and the location of the installation. The Town of Los Gatos Ordinance and West Valley Sanitation District (WVSD) requires backwater valves on drainage piping serving fixtures that have flood level rims less than 12 inches above the elevation of the next upstream manhole. 31. TOWN FIREPLACE STANDARDS: New wood burning fireplaces shall be an EPA Phase II approved appliance or gas appliance per Town Ordinance 1905. Tree limbs shall be cut within 10 feet of chimneys. 32. HAZARDOUS FIRE ZONE: All projects in the Town of Los Gatos require Class A roof assemblies. 33. WILDLAND-URBAN INTERFACE: This project is located in a Wildland-Urban Interface High Fire Area and must comply with Section R337 of the 2016 California Residential Code, Public Resources Code 4291 and California Government Code Section 51182. 34. PROVIDE DEFENSIBLE SPACE/FIRE BREAK LANDSCAPING PLAN: Prepared by a California licensed Landscape Architect in conformance with California Public Resources Code 4291 and California Government Code Section 51182. 35. PRIOR TO FINAL INSPECTION: Provide a letter from a California licensed Landscape Architect certifying the landscaping and vegetation clearance requirements have been completed per the California Public Resources Code 4291 and Government Code Section 51182. 36. SPECIAL INSPECTIONS: When a special inspection is required by CBC Section 1704, the Architect or Engineer of Record shall prepare an inspection program that shall be submitted to the Building Official for approval prior to issuance of the Building Permit. The Town Special Inspection form must be completely filled -out and signed by all requested parties prior to permit issuance. Special Inspection forms are available from the Building Division Service Counter or online at www.losgatosca.gov/building. 37. BLUE PRINT FOR A CLEAN BAY SHEET: The Town standard Santa Clara Valley Nonpoint Source Pollution Control Program Sheet (page size same as submitted drawings) shall be part of the plan submittal as the second page. The specification sheet is available at the 7of19 Resolution 2020-005 March 3, 2020 Building Division Service Counter for a fee of $2 or at ARC Blue Print for a fee or online at www.losgatosca.gov/building. 38. APPROVALS REQUIRED: The project requires the following departments and agencies approval before issuing a building permit: a. Community Development — Planning Division: (408) 354-6874 b. Engineering/Parks & Public Works Department: (408) 399-5771 C. Santa Clara County Fire Department: (408) 378-4010 d. West Valley Sanitation District: (408) 378-2407 e. Local School District: The Town will forward the paperwork to the appropriate school district(s) for processing. A copy of the paid receipt is required prior to permit issuance. TO THE SATISFACTION OF THE DIRECTOR OF PARKS AND PUBLIC WORKS: Engineering Division 39. GENERAL: All public improvements shall be made according to the latest adopted Town Standard Plans, Standard Specifications and Engineering Design Standards. All work shall conform to the applicable Town ordinances. The adjacent public right-of-way shall be kept clear of all job -related mud, silt, concrete, dirt and other construction debris at the end of the day. Dirt and debris shall not be washed into storm drainage facilities. The storing of goods and materials on the sidewalk and/or the street will not be allowed unless an encroachment permit is issued by the Engineering Division of the Parks and Public Works Department. The Owner and/or Applicant's representative in charge shall be at the job site during all working hours. Failure to maintain the public right-of-way according to this condition may result in the issuance of correction notices, citations, or stop work orders and the Town performing the required maintenance at the Owner and/or Applicant's expense. 40. APPROVAL: This application shall be completed in accordance with all the conditions of approval listed below and in substantial compliance with the latest reviewed and approved development plans. Any changes or modifications to the approved plans or conditions of approvals shall be approved by the Town Engineer. 41. PRIOR APPROVALS: All conditions per prior approvals (including Ordinance 2147, etc.) shall be deemed in full force and affect for this approval. 42. CHANGE OF OCCUPANCY: Prior to initial occupancy and any subsequent change in use or occupancy of any non-residential condominium space, the buyer or the new or existing occupant shall apply to the Community Development Department and obtain approval for use determination and building permit and obtain inspection approval for any necessary work to establish the use and/or occupancy consistent with that intended. 43. ENCROACHMENT PERMIT: All work in the public right-of-way will require a Construction Encroachment Permit. All work over $5,000 will require construction security. It is the responsibility of the Owner/Applicant to obtain any necessary encroachment permits from affected agencies and private parties, including but not limited to, Pacific Gas and Electric (PG&E), AT&T, Comcast, Santa Clara Valley Water District, California Department 8of19 Resolution 2020-005 March 3, 2020 of Transportation (Caltrans). Copies of any approvals or permits must be submitted to the Town Engineering Division of the Parks and Public Works Department prior to releasing any permit. 44. GENERAL LIABILITY INSURANCE: The property owner shall provide proof of insurance to the Town on a yearly basis. In addition to general coverage, the policy must cover all elements encroaching into the Town's right-of-way. 45. PUBLIC WORKS INSPECTIONS: The Owner and/or Applicant or their representative shall notify the Engineering Inspector at least twenty-four (24) hours before starting any work pertaining to on -site drainage facilities, grading or paving, and all work in the Town's right-of-way. Failure to do so will result in penalties and rejection of any work that occurred without inspection. 46. RESTORATION OF PUBLIC IMPROVEMENTS: The Owner and/or Applicant or their representative shall repair or replace all existing improvements not designated for removal that are damaged or removed because of the Owner and/or Applicant or their representative's operations. Improvements such as, but not limited to: curbs, gutters, sidewalks, driveways, signs, pavements, raised pavement markers, thermoplastic pavement markings, etc., shall be repaired and replaced to a condition equal to or better than the original condition. Any new concrete shall be free of stamps, logos, names, graffiti, etc. Any concrete identified that is displaying a stamp or equal shall be removed and replaced at the Contractor's sole expense and no additional compensation shall be allowed therefore. Existing improvement to be repaired or replaced shall be at the direction of the Engineering Construction Inspector and shall comply with all Title 24 Disabled Access provisions. The restoration of all improvements identified by the Engineering Construction Inspector shall be completed before the issuance of a certificate of occupancy. The Owner and/or Applicant or their representative shall request a walk-through with the Engineering Construction Inspector before the start of construction to verify existing conditions. 47. SITE SUPERVISION: The General Contractor shall provide qualified supervision on the job site at all times during construction. 48. STREET CLOSURE: Any proposed blockage or partial closure of the street requires an encroachment permit. Special provisions such as limitations on works hours, protective enclosures, or other means to facilitate public access in a safe manner may be required. 49. PLAN CHECK FEES: Plan check fees associated with the Grading Permit shall be deposited with the Engineering Division of the Parks and Public Works Department prior to the commencement of plan check review. 50. INSPECTION FEES: Inspection fees shall be deposited with the Town prior to the issuance of any grading or building permits. 51. DESIGN CHANGES: Any proposed changes to the approved plans shall be subject to the approval of the Town prior to the commencement of any and all altered work. The Owner and/or Applicant's project engineer shall notify, in writing, the Town Engineer at least seventy-two (72) hours in advance of all the proposed changes. Any approved changes shall be incorporated into the final "as -built" plans. 52. PLANS AND STUDIES: All required plans and studies shall be prepared by a Registered Professional Engineer in the State of California and submitted to the Town Engineer for 9of19 Resolution 2020-005 March 3, 2020 review and approval. Additionally, any studies imposed by the Planning Commission or Town Council shall be funded by the Owner and/or Applicant. 53. GRADING PERMIT: A grading permit is required for all site grading and drainage work except for exemptions listed in Section 12.20.015 of The Code of the Town of Los Gatos (Grading Ordinance). After the preceding Architecture and Site Application has been approved by the respective deciding body, the grading permit application (with grading plans and associated required materials and plan check fees) shall be made to the Engineering Division of the Parks and Public Works Department located at 41 Miles Avenue. The grading plans shall include final grading, drainage, retaining wall location(s), driveway, utilities and interim erosion control. Grading plans shall list earthwork quantities and a table of existing and proposed impervious areas. Unless specifically allowed by the Director of Parks and Public Works, the grading permit will be issued concurrently with the building permit. The grading permit is for work outside the building footprint(s). Prior to Engineering signing off and closing out on the issued grading permit, the Owner/Applicant's soils engineer shall verify, with a stamped and signed letter, that the grading activities were completed per plans and per the requirements as noted in the soils report. A separate building permit, issued by the Building Department, located at 110 E. Main Street, is needed for grading within the building footprint. 54. GRADING ACTIVITY RESTRICTIONS: Upon receipt of a grading permit, any and all grading activities and operations shall not commence until after/occur during the rainy season, as defined by Town Code of the Town of Los Gatos, Sec. 12.10.020, (October 15-April 15), has ended. 55. COMPLIANCE WITH HILLSIDE DEVELOPMENT STANDARDS AND GUIDELINES: All grading activities and operations shall be in compliance with Section III of the Town's Hillside Development Standards and Guidelines. All development shall be in compliance with Section II of the Town's Hillside Development Standards and Guidelines. 56. DRIVEWAY: The driveway conform to existing pavement on Santella Court shall be constructed in a manner such that the existing drainage patterns will not be obstructed. 57. CONSTRUCTION EASEMENT: Prior to the issuance of a grading or building permit, it shall be the sole responsibility of the Owner and/or Applicant to obtain any and all proposed or required easements and/or permissions necessary to perform the grading herein proposed. Proof of agreement/approval is required prior to the issuance of any Permit. 58. DRAINAGE IMPROVEMENT: Prior to the issuance of any grading/improvement permits, whichever comes first, the Owner and/or Applicant shall: a) design provisions for surface drainage; and b) design all necessary storm drain facilities extending to a satisfactory point of disposal for the proper control and disposal of storm runoff; and c) provide a recorded copy of any required easements to the Town. 59. TREE REMOVAL: Copies of all necessary tree removal permits shall be provided prior to the issuance of a grading permit/building permit. 60. SURVEYING CONTROLS: Horizontal and vertical controls shall be set and certified by a licensed surveyor or registered civil engineer qualified to practice land surveying, for the following items: a. Retaining wall: top of wall elevations and locations. 10 of 19 Resolution 2020-005 March 3, 2020 b. Toe and top of cut and fill slopes. 61. PRECONSTRUCTION MEETING: Prior to issuance of any grading or building permits or the commencement of any site work, the general contractor shall: a. Along with the Owner and/or Applicant, attend a pre -construction meeting with the Town Engineer to discuss the project conditions of approval, working hours, site maintenance and other construction matters; b. Acknowledge in writing that they have read and understand the project conditions of approval and will make certain that all project sub -contractors have read and understand them as well prior to commencing any work, and that a copy of the project conditions of approval will be posted on -site at all times during construction. 62. RETAINING WALLS: A building permit, issued by the Building Department, located at 110 E. Main Street, may be required for site retaining walls. Walls are not reviewed or approved by the Engineering Division of Parks and Public Works during the grading permit plan review process. 63. SOILS REPORT: One copy of the soils and geologic report shall be submitted with the application. The soils report shall include specific criteria and standards governing site grading, drainage, pavement design, retaining wall design, and erosion control. The reports shall be signed and "wet stamped" by the engineer or geologist, in conformance with Section 6735 of the California Business and Professions Code. 64. GEOLOGY AND SOILS MITIGATION MEASURE: A geotechnical investigation shall be conducted for the project to determine the surface and sub -surface conditions at the site and to determine the potential for surface fault rupture on the site. The geotechnical study shall provide recommendations for site grading as well as the design of foundations, retaining walls, concrete slab -on -grade construction, excavation, drainage, on -site utility trenching and pavement sections. All recommendations of the investigation shall be incorporated into project plans. 65. SOILS REVIEW: Prior to Town approval of a development application, the Owner and/or Applicant's engineers shall prepare and submit a design -level geotechnical and geological investigation for review by the Town's consultant, with costs borne by the Owner and/or Applicant, and subsequent approval by the Town. The Owner and/or Applicant's soils engineer shall review the final grading and drainage plans to ensure that designs for foundations, retaining walls, site grading, and site drainage are in accordance with their recommendations and the peer review comments. Approval of the Owner and/or Applicant's soils engineer shall then be conveyed to the Town either by submitting a Plan Review Letter prior to issuance of grading or building permit(s). 66. SOILS ENGINEER CONSTRUCTION OBSERVATION: During construction, all excavations and grading shall be inspected by the Owner and/or Applicant's soils engineer prior to placement of concrete and/or backfill so they can verify that the actual conditions are as anticipated in the design -level geotechnical report and recommend appropriate changes in the recommendations contained in the report, if necessary. The results of the construction observation and testing shall be documented in an "as -built" letter/report prepared by the Owner and/or Applicant's soils engineer and submitted to the Town before a certificate of occupancy is granted. 11 of 19 Resolution 2020-005 March 3, 2020 67. SOIL RECOMMENDATIONS: The project shall incorporate the geotechnical/geological recommendations contained in the project's design -level geotechnical/geological investigation as prepared by the Owner and/or Applicant's engineer(s), and any subsequently required report or addendum. Subsequent reports or addendum are subject to peer review by the Town's consultant and costs shall be borne by the Owner and/or Applicant. 68. DEDICATIONS: The following shall be dedicated by separate instrument. The dedication shall be recorded before any grading or building permits are issued: a. A Private Ingress Egress Easement (PIEE), twenty (20) feet in width, for the benefit of the neighboring Lot 8 to the west (15371 Santella Court; APN 527-09-035). b. Storm drainage and sanitary sewer easements, as required. 69. PUBLIC IMPROVEMENTS: The following improvements shall be installed by the Owner and/or Applicant. Plans for those improvements shall be prepared by a California registered civil engineer, reviewed and approved by the Town, and guaranteed by contract, Faithful Performance Security and Labor & Materials Security before the issuance of any grading or building permits or the recordation of a map. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. a. Santella Court: 2" overlay from the middle of the cul-de-sac to the northern lip of gutter, or alternative pavement restoration measure as approved by the Town Engineer. 70. CERTIFICATE OF OCCUPANCY: The Engineering Division of the Parks and Public Works Department will not sign off on a Temporary Certificate of Occupancy or a Final Certificate of Occupancy until all required improvements within the Town's right-of-way have been completed and approved by the Town. 71. FRONTAGE IMPROVEMENTS: The Owner and/or Applicant shall be required to improve the project's public frontage (right-of-way line to centerline and/or to limits per the direction of the Town Engineer) to current Town Standards. These improvements may include but not limited to curb, gutter, sidewalk, driveway approach(es), curb ramp(s), signs, pavement, raised pavement markers, thermoplastic pavement markings, storm drain facilities, traffic signal(s), street lighting (upgrade and/or repaint) etc. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. 72. UTILITIES: The Owner and/or Applicant shall install all new, relocated, or temporarily removed utility services, including telephone, electric power and all other communications lines underground, as required by Town Code Section 27.50.015(b). All new utility services shall be placed underground. Underground conduit shall be provided for cable television service. The Owner and/or Applicant is required to obtain approval of all proposed utility alignments from any and all utility service providers before a Certificate of Occupancy for any new building can be issued. The Town of Los Gatos does not approve or imply approval for final alignment or design of these facilities. 73. PRIVATE EASEMENTS: Agreements detailing rights, limitations and responsibilities of involved parties shall accompany any proposed private easement. Access driveway shall be within the recorded access easement. A new private access easement shall be 12 of 19 Resolution 2020-005 March 3, 2020 recorded, and a copy of the recorded agreement shall be submitted to the Engineering Division of the Parks and Public Works Department, prior to issuance of a grading or building permit. A realigned access driveway shall be completed prior to the issuance of grading or building permit. 74. CURB AND GUTTER REPAIR: The Owner and/or Applicant shall repair and replace to existing Town standards any curb and gutter damaged now or during construction of this project. All new and existing adjacent infrastructure must meet Town standards. New curb and gutter shall be constructed per Town Standard Details. New concrete shall be free of stamps, logos, names, graffiti, etc. Any concrete identified that is displaying a stamp or equal shall be removed and replaced at the Contractor's sole expense and no additional compensation shall be allowed therefore. The limits of curb and gutter repair will be determined by the Engineering Construction Inspector during the construction phase of the project. The improvements must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. 75. DRIVEWAY APPROACH: The Owner and/or Applicant shall install one (1) Town standard residential driveway approach. The new driveway approach shall be constructed per Town Standard Plans and must be completed and accepted by the Town before a Certificate of Occupancy for any new building can be issued. New concrete shall be free of stamps, logos, names, graffiti, etc. Any concrete identified that is displaying a stamp or equal shall be removed and replaced at the Contractor's sole expense and no additional compensation shall be allowed therefore. 76. SIGHT TRIANGLE AND TRAFFIC VIEW AREA: Any proposed improvements, including but not limiting to trees and hedges, will need to abide by Town Code Sections 23.10.080, 26.10.065, and 29.40.030. 77. TRAFFIC IMPACT MITIGATION FEE: Prior to the issuance of any building or grading permits, the Owner/Applicant shall pay the project's proportional share of transportation improvements needed to serve cumulative development within the Town of Los Gatos. The fee amount will be based upon the Town Council resolution in effect at the time the building permit is issued. The fee shall be paid before issuance of any grading or building permit. The final traffic impact mitigation fee for this project shall be calculated from the final plans using the current fee schedule and rate schedule in effect at the time the building permit is issued, using a comparison between the existing and proposed uses. 78. PRECONSTRUCTION PAVEMENT SURVEY: Prior to issuance of any grading or building permit, the Owner and/or Applicant shall complete a pavement condition survey documenting the extent of existing pavement defects using a smartphone video (in Landscape orientation only) or digital video camera. The survey shall extend through the Highlands of Los Gatos, from entry to the end of the Santella Court cul-de-sac. The results shall be documented in a report and submitted to the Town for review. 79. POSTCONSTRUCTION PAVEMENT SURVEY: The Owner and/or Applicant shall complete a pavement condition survey to determine whether road damage occurred as a result of project construction. Rehabilitation improvements required to restore the pavement to pre -construction condition and strength shall be determined using State of California procedures for deflection analysis. The results shall be documented in a report and submitted to the Town for review and approval before a Certificate of Occupancy for any 13 of 19 Resolution 2020-005 March 3, 2020 new building can be issued. The Owner and/or Applicant shall be responsible for completing any required road repairs prior to release of the faithful performance bond. 80. CONSTRUCTION VEHICLE PARKING: Construction vehicle parking within the public right- of-way will only be allowed if it does not cause access or safety problems as determined by the Town. 81. HAULING OF SOIL: Hauling of soil on- or off -site shall not occur during the morning or evening peak periods (between 7:00 a.m. and 9:00 a.m. and between 4:00 p.m. and 6:00 p.m.), and at other times as specified by the Director of Parks and Public Works. Prior to the issuance of a grading or building permit, the Owner and/or Applicant or their representative shall work with the Town Building Department and Engineering Division Inspectors to devise a traffic control plan to ensure safe and efficient traffic flow under periods when soil is hauled on or off the project site. This may include, but is not limited to provisions for the Owner and/or Applicant to place construction notification signs noting the dates and time of construction and hauling activities, or providing additional traffic control. Coordination with other significant projects in the area may also be required. Cover all trucks hauling soil, sand and other loose debris. 82. CONSTRUCTION HOURS: All construction activities, including the delivery of construction materials, labors, heavy equipment, supplies, etc., shall be limited to the hours of 8:00 a.m. to 8:00 p.m., weekdays and 9:00 a.m. to 7:00 p.m. weekends and holidays. The Town may authorize, on a case -by -case basis, alternate construction hours. The Owner and/or Applicant shall provide written notice twenty-four (24) hours in advance of modified construction hours. Approval of this request is at discretion of the Town. 83. CONSTRUCTION NOISE: Between the hours of 8:00 a.m. to 8:00 p.m., weekdays and 9:00 a.m. to 7:00 p.m. weekends and holidays, construction, alteration or repair activities shall be allowed. No individual piece of equipment shall produce a noise level exceeding eighty-five (85) dBA at twenty-five (25) feet from the source. If the device is located within a structure on the property, the measurement shall be made at distances as close to twenty-five (25) feet from the device as possible. The noise level at any point outside of the property plane shall not exceed eighty-five (85) dBA. 84. CONSTRUCTION MANAGEMENT PLAN SHEET: Prior to the issuance of any grading or building permits, the Owner and/or Applicant's design consultant shall submit a construction management plan sheet (full-size) within the plan set that shall incorporate at a minimum the Earth Movement Plan, Project Schedule, employee parking, construction staging area, materials storage area(s), concrete washout(s) and proposed outhouse location(s). Please refer to the Town's Construction Management Plan Guidelines document for additional information. 85. WVSD (West Valley Sanitation District): A Sanitary Sewer Clean -out is required for each property at the property line, within one (1) foot of the property line per West Valley Sanitation District Standard Drawing 3, or at a location specified by the Town. 86. SANITARY SEWER BACKWATER VALVE: Drainage piping serving fixtures which have flood level rims less than twelve (12) inches (304.8 mm) above the elevation of the next upstream manhole and/or flushing inlet cover at the public or private sewer system serving such drainage piping shall be protected from backflow of sewage by installing an approved type backwater valve. Fixtures above such elevation shall not discharge 14 of 19 Resolution 2020-005 March 3, 2020 through the backwater valve, unless first approved by the Building Official. The Town shall not incur any liability or responsibility for damage resulting from a sewer overflow where the property owner or other person has failed to install a backwater valve as defined in the Uniform Plumbing Code adopted by the Town and maintain such device in a functional operation condition. Evidence of West Sanitation District's decision on whether a backwater device is needed shall be provided prior to the issuance of a building permit. 87. BEST MANAGEMENT PRACTICES (BMPs): The Owner and/or Applicant is responsible for ensuring that all contractors are aware of all storm water quality measures and that such measures are implemented. Best Management Practices (BMPs) shall be maintained and be placed for all areas that have been graded or disturbed and for all material, equipment and/or operations that need protection. Removal of BMPs (temporary removal during construction activities) shall be replaced at the end of each working day. Failure to comply with the construction BMP will result in the issuance of correction notices, citations, or stop work orders. 88. STORMWATER DEVELOPMENT RUNOFF: All new development and redevelopment projects are subject to the stormwater development runoff requirements. The Owner and/or Applicant or their design consultant shall submit a stormwater control plan and implement conditions of approval that reduce stormwater pollutant discharges through the construction, operation and maintenance of treatment measures and other appropriate source control and site design measures. Increases in runoff volume and flows shall be managed in accordance with the development runoff requirements. 89. REGULATED PROJECT: The project is classified as a Regulated Project per Provision C.3.b.ii. and is required to implement LID source control, site design, and stormwater treatment on -site in accordance with Provisions C.3.c. and C.3.d.. 90. SITE DESIGN MEASURES: All projects shall incorporate at least one of the following measures: a. Protect sensitive areas and minimize changes to the natural topography. b. Minimize impervious surface areas. C. Direct roof downspouts to vegetated areas. d. Use porous or pervious pavement surfaces on the driveway, at a minimum. e. Use landscaping to treat stormwater. 91. GREEN ROOF: A Green roof may be considered biotreatment systems that treat roof runoff only if they meet certain minimum specifications. The green roof system planting media shall be sufficiently deep to provide capacity within the pore space of the media for the required runoff volume specified by Provision C.3.d.i.(1), in addition to supporting the long-term health of the vegetation selected for the green roof, as specified by a landscape architect or other knowledgeable professional. 92. UNLAWFUL DISCHARGES: It is unlawful to discharge any wastewater, or cause hazardous domestic waste materials to be deposited in such a manner or location as to constitute a threatened discharge, into storm drains, gutters, creeks or the San Francisco Bay. Unlawful discharges to storm drains include, but are not limited to: discharges from toilets, sinks, industrial processes, cooling systems, boilers, fabric cleaning, equipment cleaning or vehicle cleaning. 15 of 19 Resolution 2020-005 March 3, 2020 93. EROSION CONTROL: Interim and final erosion control plans shall be prepared and submitted to the Engineering Division of the Parks and Public Works Department. A maximum of two (2) weeks is allowed between clearing of an area and stabilizing/building on an area if grading is allowed during the rainy season. Interim erosion control measures, to be carried out during construction and before installation of the final landscaping, shall be included. Interim erosion control method shall include, but are not limited to: silt fences, fiber rolls (with locations and details), erosion control blankets, Town standard seeding specification, filter berms, check dams, retention basins, etc. Provide erosion control measures as needed to protect downstream water quality during winter months. The Town of Los Gatos Engineering Division of the Parks and Public Works Department and the Building Department will conduct periodic NPDES inspections of the site throughout the recognized storm season to verify compliance with the Construction General Permit and Stormwater ordinances and regulations. 94. DUST CONTROL: Blowing dust shall be reduced by timing construction activities so that paving and building construction begin as soon as possible after completion of grading, and by landscaping disturbed soils as soon as possible. Further, water trucks shall be present and in use at the construction site. All portions of the site subject to blowing dust shall be watered as often as deemed necessary by the Town, or a minimum of three (3) times daily, or apply (non -toxic) soil stabilizers on all unpaved access roads, parking areas, and staging areas at construction sites in order to insure proper control of blowing dust for the duration of the project. Watering on public streets shall not occur. Streets shall be cleaned by street sweepers or by hand as often as deemed necessary by the Town Engineer, or at least once a day. Watering associated with on -site construction activity shall take place between the hours of 8 a.m. and 5 p.m. and shall include at least one (1) late -afternoon watering to minimize the effects of blowing dust. All public streets soiled or littered due to this construction activity shall be cleaned and swept on a daily basis during the workweek to the satisfaction of the Town. Demolition or earthwork activities shall be halted when wind speeds (instantaneous gusts) exceed twenty (20) miles per hour (MPH). All trucks hauling soil, sand, or other loose debris shall be covered. 95. AIR QUALITY: To limit the project's construction -related dust and criteria pollutant emissions, the following the Bay Area Air Quality Management District (BAAQMD)- recommended basic construction measures shall be included in the project's grading plan, building plans, and contract specifications: a. All exposed surfaces (e.g., parking areas, staging areas, soil piles, graded areas, and unpaved access roads) shall be watered two times per day, or otherwise kept dust -free. b. All haul trucks designated for removal of excavated soil and demolition debris from site shall be staged off -site until materials are ready for immediate loading and removal from site. C. All haul trucks transporting soil, sand, debris, or other loose material off -site shall be covered. d. As practicable, all haul trucks and other large construction equipment shall be staged in areas away from the adjacent residential homes. e. All visible mud or dirt track -out onto adjacent public roads shall be removed using 16 of 19 Resolution 2020-005 March 3, 2020 wet power vacuum street sweepers at least once per day, or as deemed appropriate by Town Engineer. The use of dry power sweeping is prohibited. An on -site track -out control device is also recommended to minimize mud and dirt - track -out onto adjacent public roads. f. All vehicle speeds on unpaved surfaces shall be limited to fifteen (15) miles per hour. g. All driveways and sidewalks to be paved shall be completed as soon as possible. Building pads shall be laid as soon as possible after grading unless seeding or soil binders are used. h. Post a publicly visible sign with the telephone number and person to contact at the lead agency regarding dust complaints. This person shall respond and take corrective action within forty-eight (48) hours. The Air District's phone number shall also be visible to ensure compliance with applicable regulations. i. All excavation, grading, and/or demolition activities shall be suspended when average wind speeds exceed twenty (20) miles per hour. j. Vegetative ground cover (e.g., fast -germinating native grass seed) shall be planted in disturbed areas as soon as possible and watered appropriately until vegetation is established. 96. DETAILING OF STORMWATER MANAGEMENT FACILITIES: Prior to the issuance of any grading or building permits, all pertinent details of any and all proposed stormwater management facilities, including, but not limited to, ditches, swales, pipes, bubble -ups, dry wells, outfalls, infiltration trenches, detention basins and energy dissipaters, shall be provided on submitted plans, reviewed by the Engineering Division of the Parks and Public Works Department, and approved for implementation. 97. CONSTRUCTION ACTIVITIES: All construction shall conform to the latest requirements of the CASOA Stormwater Best Management Practices Handbooks for Construction Activities and New Development and Redevelopment, the Town's grading and erosion control ordinance, and other generally accepted engineering practices for erosion control as required by the Town Engineer when undertaking construction activities. 98. WATER FEATURES: New swimming pools, hot tubs or spas shall have a connection to the sanitary sewer system, subject to West Valley Sanitation District's authority and standards, to facilitate draining events. Discharges from these features shall be directed to the sanitary sewer and are not allowed into the storm drain system. 99. SITE DRAINAGE: Rainwater leaders shall be discharged to splash blocks. No through curb drains will be allowed. On -site drainage systems for all projects shall include one of the alternatives included in section C.3.i of the Municipal Regional NPDES Permit. These include storm water reuse via cisterns or rain barrels, directing runoff from impervious surfaces to vegetated areas and use of permeable surfaces. No improvements shall obstruct or divert runoff to the detriment of an adjacent, downstream or down slope property. 100. STORM WATER MANAGEMENT PLAN: A storm water management shall be included with the grading permit application for all Group 1 and Group 2 projects as defined in the amended provisions C.3 of the Municipal Regional Stormwater NPDES Permit, Order R2- 2015-0049, NPDES Permit No. CAS612008. The plan shall delineate source control 17 of 19 Resolution 2020-005 March 3, 2020 measures and BMPs together with the sizing calculations. The plan shall be certified by a professional pre -qualified by the Town. In the event that the storm water measures proposed on the Planning approval differ significantly from those certified on the Building/Grading Permit, the Town may require a modification of the Planning approval prior to release of the Building Permit. The Owner and/or Applicant may elect to have the Planning submittal certified to avoid this possibility. 101. STORM WATER MANAGEMENT PLAN CERTIFICATION: Certification from the biotreatment soils provider is required and shall be given to Engineering Division Inspection staff a minimum of thirty (30) days prior to delivery of the material to the job site. Additionally deliver tags from the soil mix shall also be provided to Engineering Division Inspection staff. Sample Certification can be found here: http://www.scvurppp-w2k.com/nd wp.shtml?zoom hiehlisht=BIOTREATMENT+SOIL. 102. SILT AND MUD IN PUBLIC RIGHT-OF-WAY: It is the responsibility of Contractor and homeowner to make sure that all dirt tracked into the public right-of-way is cleaned up on a daily basis. Mud, silt, concrete and other construction debris SHALL NOT be washed into the Town's storm drains. 103. GOOD HOUSEKEEPING: Good housekeeping practices shall be observed at all times during the course of construction. All construction shall be diligently supervised by a person or persons authorized to do so at all times during working hours. The Owner and/or Applicant's representative in charge shall be at the job site during all working hours. Failure to maintain the public right-of-way according to this condition may result in penalties and/or the Town performing the required maintenance at the Owner and/or Applicant's expense. 104. PERMIT ISSUANCE: Permits for each phase; reclamation, landscape, and grading, shall be issued simultaneously. 105. COVERED TRUCKS: All trucks transporting materials to and from the site shall be covered. TO THE SATISFACTION OF THE SANTA CLARA COUNTY FIRE DEPARTMENT: 106. FIRE SPRINKLERS REQUIRED: An automatic residential fire -sprinkler system shall be installed in one -and two-family dwellings as follows: In all new one -and two-family dwellings and in existing one -and two-family dwellings when additions are made that increase the building area to more than 3,600 square feet. Exception: A one-time addition to an existing building that does not total more than 1,000 square feet of building area. Note: The owner(s), occupant(s), and any contractor(s) or subcontractor(s) are responsible for consulting with the water purveyor of record in order to determine if any modifications or upgrade of the existing water service is required. A State of California licensed (C-16) Fire Protection Contractor shall submit plans, calculations, a completed permit application, and appropriate fees to this department for review and approval prior to beginning their work. CFC Section 313.2 as adopted and amended by LGTC. 107. WATER SUPPLY REQUIREMENTS: Potable water supplies shall be protected from contamination caused by fire protection water supplies. It is the responsibility of the applicant and any contractors and subcontractors to contact the water purveyor supplying the site of such project, and to comply with the requirements of that purveyor. 18 of 19 Resolution 2020-005 March 3, 2020 Such requirements shall be incorporated into the design of any water -based fire protection systems, and/or fire suppression water supply systems or storage containers that may be physically connected in any manner to an appliance capable of causing contamination of the potable water supply of the purveyor of record. Final approval of the system(s) under consideration will not be granted by this office until compliance with the requirements of the water purveyor of record are documented by that purveyor as having been met by the applicant(s). 2016 CFC Sec. 903.3.5 and Health and Safety Code 13114.7 108. CONSTRUCTION FIRE SAFETY: All construction sites must comply with applicable provisions of the CFC Chapter 33 and our Standard Detail and Specification SI-7. Provide appropriate notations on subsequent plan submittals, as appropriate to the project. CFC Chapter 33. 109. FIRE DEPARTMENT (ENGINE) DRIVEWAY TURNAROUND REQUIREMENT: Provide an approved fire department engine driveway turnaround with a minimum radius of 36 feet outside and 23 feet inside. Maximum grade in any direction shall be a maximum of 5%. Installations shall conform with Fire Department Standard Details and Specifications D-1. CRF Sec. 503. 110. FIRE APPARATUS (Engine) ACCESS DRIVEWAY REQUIRED: Provide an access driveway with a paved all-weather surface, a minimum unobstructed width of 12 feet, vertical clearance of 13 feet 6 inches, and a maximum slope of 15%. Installations shall conform to the Fire Department Standard Details Specifications D-1 and CFC Section 503. The proposed driveway slope of 17.2% exceeds the maximum of 15% and has received approval for a variance from the Fire Marshal's Office on 04/18/18. 111. WILDLAND-URBAN INTERFACE: This project is located within the designated Wildland- Urban Interface Fire Area. The building construction shall comply with the provisions of Section R327 of the California Residential Code or the California Building Code (CBC) Chapter 7A., as applicable. Note that vegetation clearance shall be in compliance with CBC Section 701A.3.2.4 prior to project final approval. Check with the Planning Department for related landscape plan requirements. 112. ADDRESS IDENTIFICATION: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Where required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall be a minimum of 4 inches (101.6 mm) high with a minimum stroke width of 0.5 inch (12.7 mm). Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other signs or means shall be used to identify the structure. Address numbers shall be maintained. CFC Section 505.1. 19 of 19 Resolution 2020-005 March 3, 2020 PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:21:57 PMA000Title Sheet1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 95032O L G A A R D R E S I D E N C E(APN): 527-09-036. 15365 SANTELLA COURT, LOS GATOS CALIFORNIA 95032PLANNING DEPARTMENT DEVELOPMENT APPLICATIONPlanning Backcheck Submittal 05: Jan. 08, 2020ATTACHMENT 13 DWA1011SIM101A1011Ref1Ref1Ref1Ref01View Name1/8" = 1'-0"1tNorth Arrow (Direction)Align Symbol(refers to adjacent plane)Detail Call Out(refers to view &Sheet Number)Grid Bubble(reference line call out)Datum Point or Work Pointor Control PointBuilding Section Call Out(Identifies section cut location,view direction & refersview and sheet number)Building Wall(Screened line indicate "existing"dashed lines indicate"for demolition")View Reference Symbol(indicates location of the View & Sheet numbers)View Call Out(indicates the number & scale of the drawing view)Window Symbol & Tag(indicates the location& type of the window)Door Symbol and Tag(indicates the location, direction and type of the swing door)Sliding Door Symbol and Tag(indicates the location, type of the sliding door)Vanity Unit Lavatory Faucets: ≤1.5 gpmWall Hung Water Closet. Max. 1.28 Gallons per Flush) W/ concealed cisternBath Tub101Roof DrainCook TopDish WasherFloor DrainLinear Shower DrainHose bibShower Head, 2GPM Max.Built-in Double OvenRefrigeratorRange Exhaust hoodClothes WasherClothes Dryer1A101SIMNameElevation1AY1Y64X1H292 SFB131'-2"318 SFB219 SFB416 SFB3410 SFL1500 SFL21130 SFL7137 SFL4109 SFL5710 SFG1230 SFL34'-7 1/2"17'-8"115 SFL831'-3 1/2"6'-6"65 SFL6X429'-6"16'-3 1/2"6'-8"9'-11"22'-11 1/2"17'-8 1/2"19'-0"34'-9 1/2"14'-3"14'-0 1/2"9'-7"7'-3 1/2"11'-4 1/2"9'-7 1/2"22'-4"8'-11 1/2"112 SFB58'-9"1AY1Y64X1H382 SFU1793 SFU254 SFU3240 SFU11241 SFU4537 SFU5273 SFU611 SFU723 SFU954 SFU10225 SFU813'-4 1/2"11'-1"22'-2 1/2"4'-10"17'-0"14'-0"8'-3"6'-3"17'-2"16'-1"7'-2"28'-2 1/2"28'-7 1/2"14'-10 1/2"18'-9"6'-3 1/2"X4PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:22:00 PMA100Project Data Sheet1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 95032SPEC. SPECIFICATIONSS STAINLESS STEELSSD SEE STRUCTURAL DRAWINGSSTD STANDARDSTL STEELSTRUCT. STRUCTURALSYM. SYMMETRICALT&B TOP & BOTTOMT.C. TOP OF CURBT.O. TOP OFT.O.C. TOP OF CURB/CONCRETET.O.G. TOP OF GRADET.O.P. TOP OF PARAPET/TOP OF PLATET.O.S. TOP OF STEEL/TOP OF SLABT.O.W. TOP OF WALLT.P.D. TOILET PAPER DISPENSERT.S. TUBE STEELT.V. TELEVISIONTHK. THICKTYP. TYPICALU.O.N. UNLESS OTHERWISE NOTEDUC. UNDERCUTV.I.F. VERIFY IN FIELDW.C. WATER CLOSETW.H. WATER HEATERW.P. WATER PROOFW.S. WEATHER STRIPPINGW/ WITHW/O WITHOUTWD WOODWDW WINDOWWSCT WAINSCOTWWM WELDED WIRE MESHNA NOT APPLICABLEO.C. ON CENTERO.F.C.I. OWNER FURNISHEDCONTRACTOR INSTALLEDO.F.O.I. OWNER FURNISHED OWNERINSTALLEDO.H. OPPOSITE HANDO/ OVEROPP. OPPOSITEP.H. PANIC HARDWAREP.U.E PUBLIC UTILITY EASEMENTPAV. PAVINGPLYWD. PLYWOODR.D./O.D. ROOF DRAIN/OVERFLOW DRAINR.H.M.S. ROUND HEAD MACHINE SCREWR.H.S.M.S ROUND HEAD SHEET METALSCREWR.H.W.S. ROUND HEAD WOOD SCREWR.W.L. RAIN WATER LEADERRAD. RADIUSREF. REFERENCEREFR. REFRIGERATORREQ. REQUIREDS.C. SOLID CORES.F. SQUARE FOOTAGESCD SEE CIVIL DRAWINGSSECT. SECTIONSED SEE ELECTRICAL DRAWINGSSHT. SHEETSIM. SIMILARSMD SEE MECHANICAL DRAWINGSSMS SHEET METAL SCREWSPD SEE PLUMBING DRAWINGSF.F. FINISH FLOORF.H.M.S. FLAT HEAD MACHINE SCREWF.H.W.S. FLAT HEAD WOOD SCREWF.O. FACE OFF.O.C. FACE OF CONCRETEF.O.F. FACE OF FINISHF.O.P. FACE OF PLYWOODF.O.S. FACE OF STUDFDN. FOUNDATIONFIN. FINISHFT. FOOTFURR. FURRINGG.I. GALVANIZED IRONGA. GAUGEGALV. GALVANIZEDGYP.BD. GYPSUM BOARDH.B. HOSE BIBHGT. HEIGHTINFO. INFORMATIONINSUL. INSULATIONINT. INTERIORJB. JUNCTION BOXL.D. LANDSCAPE DRAWINGSL.H. LEFT HANDMAX. MAXIMUMMECH. MECHANICALMET. METALMFR. MANUFACTURERMIN. MINIMUMMISC. MISCELLANEOUSMTD. MOUNTEDN.I.C. NOT IN CONTRACTN.T.S. NOT TO SCALECLKG. CAULKINGCLO. CLOSETCLR. CLEARCMU CONCRETE MASONRY UNITCOL. COLUMNCONC. CONCRETECONN. CONNECTIONCONT. CONTINUOUSCTR. CENTERCTSK. COUNTERSUNKD.L. DOOR LOUVERD.S. DOWNSPOUTDBL. DOUBLEDEMO. DEMOLITIONDET. DETAILDIA DIAMETER OR ROUNDDIA. DIAMETERDIM. DIMENSIONDISP. DISPENSERDN DOWNDR. DOORE.J. EXPANSION JOINTE.O.S. EDGE OF SLABE.W. EACH WAYEA. EACHELEC. ELECTRICALELEV. ELEVATIONEQ. EQUALEQPT. EQUIPMENTEXT. EXTERIORF.A. FIRE ALARMF.D. FLOOR DRAIN" INCH/INCHES# POUND/NUMBER' FOOT/FEET(E) EXISTING(N) NEW.X BY.° DEGREES.± PLUS/MINUS@ ATA.B. ANCHOR BOLTA.C. ASPHALTIC CONCRETEA.F.F. ABOVE FINISH FLOORARCH. ARCHITECTURALB.O. BOTTOM OFB.O.F. BOTTOM OF FOOTINGB.S. BOTH SIDESBD. BOARDBLDG. BUILDINGBLK. BLOCKBLKG. BLOCKINGC.D. CIVIL DRAWINGSC.F.C.I. CONTRACTOR FURNISHEDCONTRACTOR INSTALLEDC.G. CORNER GUARDC.I. CAST IRONC.J. CONTROL JOINTC.O. CLEAN OUTC.W. COLD WATERCAB. CABINETCEM. CEMENTCER. CERAMICCL CENTER LINECLG. CEILING1 EXISTING CONSTRUCTION DATA SHOWN ON THE DRAWINGS WAS OBTAINED FROM AVAILABLE DRAWINGS AND FIELDMEASUREMENTS. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND SHALL NOTIFY THE ARCHITECT OF ALLEXCEPTIONS BEFORE PROCEEDING WITH THE WORK.2 SEE ARCHITECTURAL DRAWINGS FOR LAYOUT DIMENSIONS AND ELEVATIONS EXCEPT WHERE INDICATED OTHERWISE.3 ALL DISCREPANCIES BETWEEN DRAWINGS SHALL BE CLARIFIED WITH THE ARCHITECT PRIOR TO PROCEEDING WITH WORK.4 IN THE EVENT THAT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN OR DETAILED ON THE DRAWINGS ORCALLED FOR IN THE GENERAL NOTES, THEN THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS SIMILARCONDITIONS THAT ARE SHOWN OR CALLED FOR.5 DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS SHALL BE CHECKED AND VERIFIED ON THE JOB SITE BY EACHCONTRACTOR. ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT BEFORE WORK BEGINS ORSUPPLIES ARE ORDERED6 VERIFY ELECTRICAL, MECHANICAL, FIRE ALARM, TELEPHONE AND SECURITY REQUIREMENTS BEFORE CONSTRUCTION BEGINS.8 CONTRACTOR SHALL DISPOSE OF ALL REMOVED AND/ OR DEMOLISHED MATERIAL, WASTE AND DEBRIS CAUSED BY WORK9 WORK INDICATED AS "OWNER FURNISHED, CONTRACTOR INSTALLED" (O.F.C.I.) SHALL MEET ALL APPLICABLE CODES ANDREGULATORY REQUIREMENTS INDICATED WITHIN THESE DOCUMENTS AND SHALL BE INSTALLED AND FULLY OPERATIONALPRIOR TO FINAL APPROVAL AND OCCUPANCY OF THIS PROJECT10 ALL UTILITY TRENCHES AND BUILDING PADS SHALL BE PROPERLY BACK FILLED AND COMPACTED11 PRIOR TO BUILDING PERMIT FINAL APPROVAL, THE PROPERTY SHALL BE IN COMPLIANCE WITH THE VEGETATIONMANAGEMENT REQUIREMENTS PRESCRIBED IN CALIFORNIA FIRE CODE SECTION 4906,INCLUDING CALIFORNIA PUBLICRESOURCES CODE 4291 OR CALIFORNIA GOVERNMENT CODE SECTION 51182 PER CRC R337.1.512 THIS PROJECT IS IN WILDLAND URBAN INTERFACE HIGH FIRE AREA AND MUST COMPLY WITH SECTION R337 OF THE 2016CALIFORNIA RESIDENTIAL CODE,PUBLIC RESOURCES CODE 4291 AND CALIFORNIA GOVERNMENT CODE SECTION 51182. ALLEXTERIOR BUILDING MATERIALS SHALL CONFORM TO SFM CHAPTER 12-7A MATERIALS AND CONSTRUCTION METHODS FOREXTERIOR WILDFIRE EXPOSURE SYSTEMOLGAARD RESIDENCEDEVELOPMENT OF A NEW, TWO LEVEL, SINGLE FAMILY DWELLINGPROJECT DESCRIPTIONPROPERTY & BUILDING DIMENSIONAL COMPLIANCE ZONING ASSESSOR PARCEL NUMBER:CONSTRUCTION CITY:ADDRESSTOTAL SITE AREA:OCCUPANCY TYPE:LOT NO.:HR-2 1/2; PDLos Gatos527-09-03615365 Santella CourtV-NR/ Sprinklered - V-B2 AcresR-3 Single Family Dwelling9BUILDING DATAGROSS LOT SIZEREQ'D /ALLOWEDPROPOSED"SETBACKS"MINIMUM FRONT YARD - ROADMINIMUM SIDE YARDMINIMUM SIDE YARDMINIMUM REAR YARDMAXIMUM BUILDING HEIGHTAVERAGE LOT SLOPE TOTAL UPPER LEVEL DECK AREASFLOOR AREA RATIO (F.A.R) ALLOWABLE FLOOR AREATOTAL HABITABLE BUILDING AREA (including Basement Area) COVERED PARKINGGARAGE AREAFRONT PARKING AND FIRE TRUCK TURN AROUND AREALOWER (BELOW DECK) PATIO AREABELOW GRADE AREAOFF STREET (UNENCLOSED) PARKINGFRONT DRIVE WAY AREATOTAL IMPERVIOUS SURFACE (LOT COVERAGE) AREA REMAINING HARDSCAPE AREAGROSS LOT SIZE MINUS DRIVEWAY ARMDRIVEWAY PORTION OF LOT AREA (Narrow Width)NET LOT SIZESouthEastWestNorth25'-0"22'25'0"25'0"20'0"66'0"20'0"106'0"30'0"266'0"236285 SFNA7.3%756 SF31.18%NA32,271 SF6,000 SF5,840SF711 SF890 SF3956 SF233174 SF17,617 SF5882 SF87,475 SF6,797 SF400 SF1447 SFThe Project scope involves site development, design and construction of a two level, 4 bed, 4 1/2 bath and 3 car garage, single family dwelling of 6285 sf floor area on a 2 acre, hill side, vacant lot .APPLICABLE BUILDING CODES -2016 CALIFORNIA BUILDING CODE:Part 1 Administrative CodePart 2 California Building Code (CBC), VOL. 1 & 2Part 2.5 California Residential Code (CRC)Part 3 California Electrical Code (CEC)Part 4 California Mechanical Code (CMC)Part 5 California Plumbing Code (CPC)Part 6 California Energy CodePart 8 California Historical Building CodePart 9 California Fire Code (CFC)Part 11 California Green Building Standards Code (CAL Green)Part 12 California Reference Standards CodeNation 2009 Los Gatos Town CodeAnd all other local and state laws and regulationsGOVERNING CODESABBREVIATIONSSYMBOL LEGENDGENERAL NOTESVICINITY MAPPARCEL MAP(APN): 527-09-036. Address: Lot 9,15365 Santella Court, Los Gatos CA 95032PROJECT DIRECTORYOWNERCHRISTIAN OLGAARD & HELEN OLGAARD21355 SARATOGA HILLS ROADSARATOGA CA 95070PHONE:(408) 505 7715EMAIL:CHRISTIAN@OLGAARD.COMSHEETNUMBERSHEET NAMEA000 Title SheetA100 Project Data SheetA102 SiteplanA103 Lower Level Floor PlanA104 Upper Level Floor PlanA105 Roof PlanA106 Building ElevationsA108 Building SectionsA109 Building SectionsA110 Building SectionsA115 Perspective Views-01A116 Perspective Views 02A117 Axonometric ViewsA118 Elevations with Exterior Materials IdentifiedC1 Cover SheetC2 Stormwater Pollution Prevention PlanC3 Existing TopographyC4 Grading and Drainage PlanC5 Driveway Plan and ProfileC6 Grading and Drainage PlanC7 Section and DetailsC8 Erosion Control PlanL1.0 Planting PlanL2.0 Fence Plan and Wall DetailsL2.1 Driveway Gate Plan and DetailsL2.2 DetailsL3.0 Tree PlanAllowable Floor Area & Calculation TableNameAreaCommentsL1410.11 SF Lower floor Area enclosed space that exceeds 4 feet( in height) above adjacent grade)L2499.68 SF Lower floor Area enclosed space that exceeds 4 feet( in height) above adjacent grade)L3229.70 SF Lower floor Area enclosed space that exceeds 4 feet( in height) above adjacent grade)L4136.86 SF Lower floor Area enclosed space that exceeds 4 feet( in height) above adjacent grade)L5108.77 SF Lower floor Area enclosed space that exceeds 4 feet( in height) above adjacent grade)L665.41 SF Lower floor Area enclosed space that exceeds 4 feet( in height) above adjacent grade)L71130.27 SF Lower floor Area enclosed space that exceeds 4 feet( in height) above adjacent grade)L8114.84 SF Lower floor Area enclosed space that exceeds 4 feet( in height) above adjacent grade)Lower floor Area enclosed space thatexceeds 4 feet( in height) aboveadjacent grade)2695.65 SFU1381.96 SF Upper Floor AreaU2793.33 SF Upper Floor AreaU353.57 SF Upper Floor AreaU4241.28 SF Upper Floor AreaU5536.87 SF Upper Floor AreaU6273.46 SF Upper Floor AreaU710.86 SF Upper Floor AreaU8225.17 SF Upper Floor AreaU922.63 SF Upper Floor AreaU1054.34 SF Upper Floor AreaU11239.96 SF Upper Floor AreaUpper Floor Area2833.42 SFTotal Enclosed Gross Floor Area 5529.07 SF1" = 20'-0"1Lower Level Floor Area Calculation DiagramBasement Floor Area & Calculation TableName AreaCommentsB1292.24 SF Basement Area (enclosed space that does not extend 4 fee in height) above adjacent grade)B2318.14 SF Basement Area (enclosed space that does not extend 4 fee in height) above adjacent grade)B315.58 SF Basement Area (enclosed space that does not extend 4 fee in height) above adjacent grade)B418.58 SF Basement Area (enclosed space that does not extend 4 fee in height) above adjacent grade)B5111.71 SF Basement Area (enclosed space that does not extend 4 fee in height) above adjacent grade)Total Enclosed Basement Floor Area 756.25 SF1" = 20'-0"2Upper Level Floor Area Calculation DiagramARCHITECTHARI SRIPADANNA AIA LEEDAP SRUSTI ARCHITECTS18524 MONTPERE WAY SARATOGA CA 95070PHONE:(408) 507 8138EMAIL:HARI@SRUSTIARCHITECTS.COMSTRUCTURAL ENGINEERDOUG ROBERTSON, S.E.DAEDALUS STRUCTURAL ENGINEERING, 12930 SARATOGA AVENUE, STE B9, SARATOGA, CA 95070PHONE:(408) 517 0373 EMAIL:DOUG@DAEDALUS-ENG.COMLANDSCAPE ARCHITECTDAVID FOX, ASLADAVID R FOX & COMPANY. 1188 KOTENBURG AVE,SAN JOSE, CA 95125PHONE:(408) 761 0212 EMAIL:DAVID@FOXLA.NETFLOOR AREA CALCULATION DIAGRAMGarage Floor Area & Calculation TableName AreaCommentsG1710.44 SF Garage /Utilities Area (enlcosed area over 400 sf. shall be counted towards F.A.R)Total Enclosed Garage Floor Area 710.44 SFGarage Floor area Exemption 400.00 SFRemaing Garage Floor Area after Exemption= 310.44 SFPROPOSED TOTAL ALLWABLE FLOOR AREA=5529.07+310.44= 5,840 SF.CIVIL ENGINEERAMANDA (WILSON) MUSY-VERDEL HANNA-BRUNETTI7651 EIGLEBERRY STREET,GILROY ,CA 95020 PHONE: (408) 842-2173EMAIL:AMANDA@HANNABRUNETTI.COMMECH. & PLUMB. ENGINEERELECTRICAL ENGINEERLEED CONSULTANTSHANNON ALLISONALTER CONSULTING ENGINEERS1091 56th STREETOAKLAND CA, 94608PHONE: (510)-406-8535EMAIL: SHANNON@ALTERENGINEERS.COMDEFERRED SUBMITTALS1. Fire sprinkler system (NFPA 13-D 2016 Addition Standard) shall be installed throughout the entire structure under a separate permit. Fire SprinklerContractor shall obtain a prior approval from Water Utility Companybeforeinstallation.2. Contractor shall furnish the design and construction and installation of anapproved fire sprinkler system. The design shall be provided by an approved fire sprinkler contractor that is licensed to work in the state. 3. All labor, materials, valves, equipment and services necessary to complete theproject shall be included. Layout drawings, design and equipment lists must bereviewed and approved by the Fire Marshall and the building Departmentprior to installation. Drawings shall show the building to be completelysprinklered throughout, all concealed areas including attic and garages.DAVID MAINO ATIUM ENGINEERING3533 YORK LN SAN RAMON, CA 94582 PHONE: (913) 961-1658EMAIL: MAINO@ATIUMENG.COMDEVIN (KURTZ) JOHNSONBRIGHT GREEN STRATEGIES INC.1717 SEABRIGHT AVE. SUITE 4, SANTA CRUZ, CA 95062PHONE: (510) 863-1109 ext. 1006EMAIL: DEVIN@BRIGHTGREENSTRATEGIES.COMFire sprinkler system (NFPA 13-D 2016 Addition Standard) shall be installed throughout the entire structure under a separate permit. Fire Sprinkler Contractor shall obtain a prior approval from Water Utility Companybefore installation.80,678 SFPlanning Backcheck Submittal 05: Jan. 08, 2020 DN692'-0" 694'-0" 690'-0" 692'-0" 694'-0" 686'-0" 688'-0" 690'-0" 692'-0" 694'-0" 686'-0" 688'-0" 690'-0" 692'-0" 694'-0" 690'-0" 692'-0" 694'-0" 6 9 0 '-0 " 6 9 2 '-0 " 6 9 4 '-0 " 3A1081AY1Y6X12A1094A1102A110X4F.F 688.00EXT. F.G. 694.00693.50693.5021Extent of (from #1 to #2 ) enclosed Basement area that does not extend 16'0"X16'6"Media Room12'0"X10'0"Wine Cellar4'8"X6'0"Closet5'10"X6'6"Bath11'10"X15'10 1/2"Bedroom-Hallway9'8"X13'7"Studio9'6"X7'9"Storage13'8"X8'4"Lower Foyer-Hallway15'9"X15'3"Bedroom13'0"X17'7"Lower Entry CourtyardAREA OF FILL (3ft. Max. Ht. from <E> Grade)EXT. F.G. 693.50693.50EXT. F.G. 693.50EXT. F.G. 693.50EXT. F.G. 693.5017% SLOPE15% SLOPE16% SLOPEBasement area (756.25 SF.) not be included in the floor area ratio calculation13'4"X5'11"Wet BarEXT. F.G. 694.00EXT. F.G. 694.00TOW 690.00TOW 693.00TOW 690.212A101EXT. F.G. 688.00EXT. F.G. 688.00EXT. F.G. 688.00TOW 687.753A101more than four (4) feet above the existing or finished exterior grade.15% SLOPECUTFILLLower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"2A108Y1Y2Y6Y4Y3Y52A1094A110Basement Ceiling Level 697' - 5"Basement Ceiling Level 697' - 5"To Ceiling Ht.From Finished Ext. Grade3'-5"<E> GRADE<E>GRADE<E>GRADEFILL2'-3"EXT. <E> Grade 694' - 0"CUT3'-6"Daylight Well F.G. 690' - 6"CUT6'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"3A108X3X12A110X4X2CUT6'-0"Basement Ceiling Level 697' - 5"To Ceiling Ht.From Finished Ext. Grade3'-5"FILLMAX3'-0"FILLMAX3'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:22:08 PMA101Basement Diagrams1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 950323/16" = 1'-0"1Enlarged Basement Floor Plan3/16" = 1'-0"2Partial Southwest Elevation3/16" = 1'-0"3Partial Northwest ElevationLEGENDPlanning Backcheck Submittal 05: Jan. 08, 2020 DN 592' 594' 596' 598' 600' 602' 604' 606' 608' 610' 612' 614' 616' 618' 620' 622' 624' 626' 628' 630' 632' 634' 636' 638' 640' 642' 644' 646' 648' 650' 652' 6 5 4 ' 654' 656' 656' 658' 658' 660' 660' 662' 662' 664' 664' 6 66' 666' 668' 668' 670' 670' 672' 672' 6 7 4' 674' 6 7 6' 676' 6 7 8' 678' 6 8 0' 680' 682' 682' 684' 684' 592' 592' 594' 596' 598' 600' 602' 604' 606' 608' 610' 612' 614' 616' 618' 620' 622' 624' 626' 628' 630' 632' 634' 636' 638' 640' 642' 644' 646' 648' 650' 652' 654' 656' 658' 660' 662' 664' 666' 668' 670' 672' 674' 676' 678' 680' 682' 684' 686' 688' 690' 692' 694' 696' 6 5 4 ' 6 5 6 ' 6 5 8 ' 6 6 0 ' 6 6 2 ' 664' 666' 6 6 8 ' 670' 672' 674' 67 6' 6 78' 680' 682' 684' 686' 688' 6 9 0' 6 9 2' 694' 696' 698' 700' 7 0 2 ' 704' 7 0 6' 7 0 8 ' 7 1 0 ' 7 1 2 ' 7 1 4 ' 7 1 6 ' 718' 720' 16' - 0"18' - 0"L R D A LRDALRDALRDAL R D A L R D AUTILITY EASEMENTXX#671Fair ConditionBLUE OAKX#675Fair ConditionBLUE OAKXX#662Good ConditionBLUE OAKSANTELLA CT.X#676Poor ConditionX#660Good ConditionBLUE OAKX#652Fair ConditionBLUE OAK#674Poor ConditionVALLEY OAK#668Poor ConditionBLUE OAK#682Fair ConditionBLUE OAKUTILITY EASEMENTUTILITY EASEMENTUTILITY EASEMENTLR D A LRDALRDAL R D A LRDAPRIV A TE SC EN IC EA SEM EN TPRIVATE SCENIC EASEMENTPRIVATE SCENIC EASEMENT#684Poor ConditionVALLEY OAK#683Poor ConditionBLUE OAK#685Poor ConditionVALLEY OAK#681Fair ConditionBLUE OAK#680Fair ConditionBLUE OAK#679Good ConditionBLUE OAK+680'+675'+670'+665'+692'Upper DeckLower PatioEntry StairLower Entry CourtGarage Entry/ Visitor ParkingEntry Way#653Fair ConditionBLUE OAK#654Good ConditionBLUE OAK#665Fair ConditionBLUE OAK#664Good ConditionBLUE OAK#663Fair ConditionBLUE OAK#661Good ConditionBLUE OAK#659Good ConditionBLUE OAK#667Fair ConditionCOAST LIVE OAK#666Fair ConditionBLUE OAK627Fair ConditionBLUE OAK#657Good ConditionBLUE OAK626Fair ConditionBLUE OAK#658Good ConditionBLUE OAK#670Fair Condition#669Fair ConditionBLUE OAKA1061A1064A1062A1063X#656Fair ConditionBLUE OAK624Good ConditionBLUE OAK236BLUE OAK623Good ConditionBLUE OAK622Good ConditionBLUE OAK677Good ConditionCOAST LIVE OAK1AY1Y64X1HXXLOT #9LOT #8LOT #10#244BLUE OAKBLUE OAKCOAST LIVE OAKLRDALRDAVIEW DIRECTION FROM SELINDA WAYXX4A1072A1074A1073A1075-A1076A1077A1078X620Good ConditionBLUE OAK#678Fair ConditionBLUE OAKX#691Doesn't ExistCOAST LIVE OAKX#634Fair ConditionVALLEY OAK#690Fair ConditionBLUE OAKPROPERTY LINE536.48'PROPERTY LINE536.48'BLUE OAKPROPERTY LINE30.22'P R O P ER TY LIN E3 3 3 .5 2 'P R O P ER TY LIN E 3 3 3 .5 2 'P R O P ER TY LIN E 3 3 3 .5 2 'P R O P E R T Y L I N E 9 2 .5 2 'PROPERTY LINE23.14'P R O P E R TY L I N E 15 3 .1 2 'PROPERTY LINE34.00'P R O P E R T Y L I N E 15 3 .1 2 'PROPERTY LINE410.10'PROPERTY LINE410.10'PROPERTY LINE410.10'PROPERTY LINE536.48'PROPERTY LINE410.10'REQ D . SID EYA RD SETBA C K20'-0"REQD. REARYARD SETBACK25'-0"REQD. REARYARD SETBACK25'-0"REQ D . SID EYA RD SETBA C K20'-0"PROVIDED SETBACK66'-0"PRO V ID ED SETBA C K106'-0"DRIVEWAY GATESee Landscape DrawingsTrash EnclosureVIEW DIRECTION FROM BLOSSOMHILL ROADA1181A1182A1183A1184Mailbox & Address Numbersper Santa Clara County FireDepartment StandardsASSUMED FRONTYARD PROPERTYLINER E Q U IR E DFRONT Y A R D S E TB A C K 3 0 '-0 "15358 X2Good ConditionBLUE OAKX1Good ConditionBLUE OAKZ5Good ConditionBLUE OAKZ2Good ConditionBLUE OAKZ3Good ConditionBLUE OAKY1Good ConditionBLUE OAKY2Good ConditionVALLEY OAKY4Good ConditionBLUE OAKY3Good ConditionBLUE OAKZ4Good ConditionBLUE OAKOutline of the Building Lot # 8 Driveway Entrance18'-0"Shared Driveway18'-0"Shared Driveway18'-0"Private Driveway16'-0"Roof Overhang2'-4 3/4"PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:28:57 PMA102Siteplan1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 950321" = 20'-0"1Site PlanA1Planning Backcheck Submittal 05: Jan. 08, 2020 DN DNDNDNDNDNDNDN D NDN DNDNDNDNDNDN12'0"X10'0"Wine Cellar16'0"X16'6"Media Room4'8"X6'0"Closet5'10"X6'6"Bath11'10"X15'10 1/2"Bedroom9'8"X13'7"Studio3'0"X7'0"Mech Rm.15'9"X15'3"Bedroom6'0"X9'3"Bath6'0"X5'7 1/2"Closet18'0"X15'5"Lower Family Room16'0"X17'8"Master Bedroom16'0"X9'9 1/2"Master Bath16'0"X7'7"Master Closet12'0"X8'7"Laundry16'0"X6'0"Mud Room8'9.5"X6'0"Mech/Pool Equip. Rm.8'0"X6'0"Elec. Rm22'1"X31'11"GarageLower PatioEntry StairGarage Entry/ Visitor ParkingEntry WayDrive Way1A10813'0"X17'7"Lower Entry Courtyard49'7 1/2"X12'10"Lower Patio-Outdoor Fire Place-Hallway3A1084A1082A10812DCAY1Y2Y63BEG2.24G9Y42.52.6X3X1Y3D9A1Y5F6H1A109LRDALRDALRDALRDALRDALRDALRDALRDA2A1093A1094A1091A1103A1104A11013'4"X5'11"Wet Bar9'6"X7'9"Storage13'8"X8'4"Lower Foyer2A110X4X2FPoolWest Upper Deck Abv.OW03ED02OW02ED05ED05OW02EGD01EGD02ED07ID02ID02ID03ID02ID02690.50689.00ID10ID11-HallwayED04ID02ID12ID08ID03ID06ID02ID03ID02ID03ID13ID02ID11ID05OW03CW3W02ID03ID13CW7W01CW 6W 01OW02OW02CW3W04ID03ID02ID03ID03ID03OW02CW7W02CW7W03OW02CW3W07LCW3W07R5%F.F 688.00F.F 688.002%5%5%ID09TOW 689.50ID07690.174'0"X6'2"Store RoomED06690.50690.75PROPERTY LINE333.52'A1011REAR PROPERTY SETBACK25'-0"PROPERTY LINE536.48'42" High-Metal Railing with Glass Panel Infill andWood Hand Rail(Comply w/ C.B.C 1012 & 1013)42" High-Metal Railing with Glass Panel Infill andWood Hand Rail(Comply w/ C.B.C 1012 & 1013)SID EY A R D SE TB A C K20'-0"46'-8"40'-2"6'-6"107'-10 1/2"1'-3 3/4"11'-2"15'-8"12'-3 1/2"11'-2"1'-3 3/4"16'-1 3/4"9'-2 1/2"7'-1"19'-5"3'-1 1/4"47'-6"8'-11 1/2"6'-8 1/2"5'-10"4'-2"8'-4"13'-6"39'-3"5'-9"17'-0"16'-6"ED06ID10ED06OW0333'-2 1/2"4'-6 1/2"17'-6 1/2"22'-1"Outdoor Fireplace shall comply with the CBC and the Highlands of Los Gatos CC&R’s. 680678676674672PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:53:50 PMA103Lower Level FloorPlan1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 950321/8" = 1'-0"1Lower Level Floor Plan11Key NotesProvide Signage that this room will not be used for sleepingA2Planning Backcheck Submittal 05: Jan. 08, 2020 DND N DN DN DNDND N DN18"X15'0"Dining21'0"X15'0"Kitchen10'0"X5'0"Breakfast Nook15'0"X20'0"Upper Family Room5'6"X5'0"Toilet12'0"X12'0"Office7'2"X6'4"Bath12'0"X12'0"Bedroom4'6"X6'4"Closet16'0"X13'0"Upper Foyer22'0"X16'0"Living RoomLower PatioEntry StairLower Entry CourtyardGarage Entry/ Visitor ParkingEntry WayDrive WayLRDALRDALR D A 46'-8"40'-2"6'-6"1A1083A1084A1082A10812DCAY1Y2Y63BEG2.24G9Y42.52.6X3X1Y3D9A1Y5F6H9'-0"X17'8"Play Loft11'0"X17'8"Attic/Storage1A109689.00688.38LRDALRDALRDALRDALRDA2A1093A1094A1091A1103A1104A1102A110X4-Hallway15'6X16'4"Upper West Deck-East Upper DeckX2FCW7W05CW3W06RCW3W06LOW02ED05OW02OW02OW01OW01OW02OW02OW02OW02CW7W02CW3W03CW3W01CW2W02CW2W01CW2W04CW7W04CW 6W 02CW 6W 01CW7W01CW3W05CW8W01CW2W03ED03ID01CW9W02C W 9 W 0 1 ID05ID02ID03ID03ID04ED02697.431%695.33690.50698.883%2%5%5%5%698.94F.F 699.00ED05PoolCW 11W 02ID13694.00TOW 693.00TOW 690.21TOW 695.73689.50689.50700.00690.50690.42689.54689.00690.00690.17REAR PROPERTY SETBACK25'-0"SID EY A R D SE TB A C K20'-0"697.38107'-10 1/2"1'-3 3/4"11'-2"15'-8"12'-3 1/2"11'-2"1'-3 3/4"16'-1 3/4"9'-2 1/2"7'-1"19'-5"3'-1 1/4"47'-6"8'-11 1/2"6'-8 1/2"5'-10"4'-2"8'-4"13'-6"39'-3"5'-9"17'-0"16'-6"MOW06MOW04MOW20CW3W03PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:29:08 PMA104Upper Level FloorPlan1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 950321/8" = 1'-0"1Upper Level Floor PlanPlanning Backcheck Submittal 05: Jan. 08, 2020 Upper DeckLower DeckEntry StairLower Entry CourtGarage Entry/ Visitor ParkingEntry WayDrive Way1A1083A1084A108A1061A10632A10812DCAY1Y2Y63BEG2.24G9Y42.52.6X3X1Y3D9A1Y5F6H1A109LRDALRDALRDALRDALRDALRDALRDALRDA689.00688.38698.94694.00689.50 TOW689.50 TOW2A1093A1094A1091A1103A1104A1102A110X4X2FA1071A1072A1074A1073A1075-A1077A107819%1%1%1%2%1%17%19%Class "A" Single-Ply Membrane Roofing (CoolRoof)Vegetative Green Roof SystemVegetative Green Roof SystemRoofing Ballast (white colored gravel)Roofing Ballast (white colored gravel)Roofing Ballast (white colored gravel)Vegetative Green Roof SystemVegetative Green Roof SystemRoofing Ballast (white colored gravel)Solar Photovoltaic System-(See PV Drawings)?Roof DrainSolar Photovoltaic System-(See PV Drawings)A1182A118346'-8"40'-2"6'-6"107'-10 1/2"1'-3 3/4"11'-2"15'-8"12'-3 1/2"11'-2"1'-3 3/4"16'-1 3/4"9'-2 1/2"7'-1"19'-5"3'-1 1/4"47'-6"8'-11 1/2"6'-8 1/2"5'-10"4'-2"8'-4"13'-6"39'-3"5'-9"17'-0"16'-6"711.00711.00701.00701.00701.00701.00697.78697.79716.00716.001%710.64710.64711.00711.00710.64710.64716.00716.00711.83699.00690.44711.00701.00Roof overhang projection2'-4 3/4"Roof Drain695.19689.54PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:50:17 PMA105Roof Plan1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 950321/8" = 1'-0"1Roof PlanPlanning Backcheck Submittal 05: Jan. 08, 2020 Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"4A1081232.242.52.64A1093A11025' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level<E>GRADE22'-0"<E> GRADE35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"1A108Roof's Highest Point716'-0"DCABEGG9D9A1F6H1A1093A1091A110F25' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level22'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"4A1081232.242.52.64A1093A11025' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level22'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"1A108Roof's Highest Point716'-0"DCABEGG9D9A1F6H1A1093A1091A110F25' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level22'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:29:34 PMA106Building Elevations1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 950321/8" = 1'-0"1South Elevation1/8" = 1'-0"2East Elevation1/8" = 1'-0"3North Elevation1/8" = 1'-0"4West ElevationPlanning Backcheck Submittal 05: Jan. 08, 2020 Lower Floor Level688'-0"Upper Floor Level699'-0"3'-0"2'-0"2'-0"1'-6"6"2'-0"2'-0"6'-0"4'-0"2'-0"3'-6"2'-0"4'-0"4'-0"8'-0"CW2W02CW2W01CW2W04CW10W01CW3W028'-0"4'-0"2'-0"OW037'-2 1/2"1'-6 3/4"2'-9"ED07ID094'-0"CW2W02CW3W03MOW206'-0"6'-0"2'-0"8'-0"6'-0"Exisiting AdjacentGrade694'-0"Upper Floor Level699'-0"6'-0"2'-0"4'-0"8'-0"13'-0"5'-8"2'-4"4'-0"4'-0"6'-0"2'-0"3'-0"3'-6"5'-0"3'-0"CW6W01ED02CW6W02CW12W038'-0"2'-0"15'-8"CW11W02CW11C01Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"8'-0"3'-0"2'-0"5'-0 3/4"5'-9"6'-0"2'-0"2'-3 3/4"4'-0"4'-0"3'-6 3/4"4'-0"4'-0"11'-6 3/4"4'-0"2'-0"6'-0"6'-0"8'-0"2'-0"3'-5 1/2"4'-0"2'-0"5'-5 3/4"6'-0"6'-0"2'-0"6'-0"2'-0"8'-0"2'-4"ED03CW2W03CW8W01CW3W05OW02OW02CW7W012'-0"4'-0"3'-0"3'-7 1/2"2'-0"4'-0"OW03CW10W01CW3W04CW7W01OW02OW02CW12W014'-0"4'-0"2'-0"3'-0"8'-0"9'-0"5'-7"CW11C01CW11W0275.9 6 °75.9 6 °Exisiting AdjacentGrade694'-0"Upper Floor Level699'-0"6'-0"2'-0"6'-0"2'-0"12'-0"12'-0"2'-0"2'-0" 4'-0"4'-0" 2'-0"CW7W04OW02CW9W02CW9W01CW12W028'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"EGD02EGD0116'-2"8'-2"8'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"2"7'-8 1/2"8'-0"2'-0"6'-0"2'-0" 4'-0"4'-0" 3'-0"13'-0"3'-0" 4'-0"4'-0" 2'-0"13'-0"2'-0"6'-0"8'-0"13'-0"3'-1 1/4" 3'-1 1/4" 3'-1 1/4" 3'-4 3/4"6'-0"2'-0"4'-0"2'-0"6'-0"8'-0"2'-0"6'-0"8'-0"2'-0"4'-0"2'-0"6'-0"3'-0" 4'-0" 2'-0"2'-0" 4'-0"2'-0"6'-0"9'-0"2'-0" 4'-0" 3'-0"9'-0"2'-0" 4'-0"4'-0" 3'-4 1/2"6'-0"4'-0"3'-4"ED06CW3W07ROW02CW3W03OW01CW3W01OW01ED05CW3W06LOW02CW3W06ROW02ED05CW7W05OW02CW10W01OW03OW02CW7W03ED02CW3W07LED05OW02ED05CW2W04ED06Exisiting AdjacentGrade694'-0"Ceiling Level709'-0"709' - 0"Roof2'-10"2'-6"15'-8"CW4W01MOW01MOW01MOW01MOW013'-11"3'-11"3'-11"3'-11"Ceiling Level709'-0"2'-6"2'-10"2'-0"CW1W01LPROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:29:35 PMA107Door WindowSchedules1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 950321/4" = 1'-0"5South Garage Door ElevationWindow ScheduleMark Width Height CountDescriptionCommentsMOW01 3' - 9 3/4" 2'-4 1/2" 4 Motorized Awning WindowMOW04 2' - 4" 4'-10" 1 Operable Skylight with curbMOW06 2' - 4" 4'-10" 1 Operable Skylight with curbMOW14 2' - 0" 6'-0" 1 2 3/4"" Wall Recess with 1 1/2" Thick Wood SillMOW15 2' - 0" 4'-0" 1 2 3/4"" Wall Recess with 1 1/2" Thick Wood SillMOW16 4' - 0" 2'-0" 1 2 3/4"" Wall Recess with 1 1/2" Thick Wood SillMOW20 1' - 10 3/4" 3'-10 3/4" 1 Casement WindowOW01 1' - 10 1/2" 3'-10 3/4" 3OW02 1' - 10 3/4" 5'-10 3/4" 13 Casement WindowOW03 3' - 10 1/2" 1'-10 1/2" 3 Awning WindowWN01 2' - 0" 4'-0" 3 2 3/4"" Wall Recess with 1 1/2" Thick Wood SillWN02 2' - 0" 6'-0" 3 2 3/4"" Wall Recess with 1 1/2" Thick Wood SillWN03 4' - 0" 2'-0" 3 2 3/4"" Wall Recess with 1 1/2" Thick Wood SillGrand total: 38Curtain Wall ScheduleMark Length Height CountDescriptionCommentsCW1 W01L 6' - 0" 2'-6" 1 Fixed window with no interior horizontal mullionsCW1 W01R 6' - 0" 2'-6" 1 Fixed window with no interior horizontal mullionsCW2 W01 2' - 0" 6'-0" 1 Fixed window with interior horizontal mullion at 2'-0" Ht.CW2 W02 2' - 0" 8'-0" 1 Fixed window with interior horizontal mullion at 2'-0" Ht.CW2 W03 4' - 0" 8'-0" 1 Fixed window with interior horizontal mullion at 2'-0" Ht.CW2 W04 8' - 0" 4'-0" 2 Fixed window with interior horizontal mullion at 2'-0" Ht.CW2 W05 6' - 0" 8'-0" 1 Fixed window with interior horizontal mullion at 2'-0" Ht.CW3 W01 2' - 0" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht.CW3 W02 6' - 0" 5'-6" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht.CW3 W03 6' - 0" 6'-0" 2 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht.CW3 W04 6' - 0" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht.CW3 W05 9' - 0" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht.CW3 W06L 9' - 0" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht.CW3 W06R 9' - 0" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht.CW3 W07L 13' - 0" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht.CW3 W07R 13' - 0" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht.CW4 W01 15' - 8" 2'-6" 1 Curtain Wall inset with motorized clearstory awning windowsCW5 W01 3' - 0" 5'-0" 1 Fixed window without corner vertical mullionCW6 W01 3' - 0" 8'-0" 2 Interior horizontal mullion at 2ft. Ht. & without corner vertical mullionCW6 W02 4' - 0" 8'-0" 1 Interior horizontal mullion at 2ft. Ht. & without corner vertical mullionCW7 W01 5' - 5 1/2" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht. & without a corner verticalmullionCW7 W01 5' - 7" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht. & without a corner verticalmullionCW7 W02 6' - 0" 8'-0" 2 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht. & without a corner verticalmullionCW7 W03 13' - 4" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht. & without a corner verticalmullionCW7 W04 12' - 0" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht. & without a corner verticalmullionCW7 W05 13' - 4" 8'-0" 1 2'0" wide Casement window inset, & an interior Horizontal Mullion at 2'-0" Ht. & without a corner verticalmullionCW8 W01 11' - 8 1/2" 5'-0" 1 Slanted mullion on one side & without corner vertical mullionCW9 W01 6' - 9" 8'-0" 1 Segmented along a curved wall & horizontal mullion at 2-'0"Ht.CW9 W02 9' - 0" 8'-0" 1 Segmented along a curved wall & horizontal mullion at 2-'0"Ht.CW10 W01 4' - 0" 2'-0" 3 Inset Awning windowCW11 C01 3' - 6" 5'-0" 1 Curtain Wall-SlantedCW11 W02 8' - 0" 5'-8" 1 Curtain Wall-SlantedCW12 W01 8' - 0" 2'-0" 1 Louvered ventsCW12 W02 12' - 0" 2'-0" 1 Louvered ventsCW12 W03 15' - 8" 2'-0" 1 Louvered ventsGrand total: 41Door ScheduleMark Width Height FunctionCountDescriptionCommentsED01 5' - 0" 7'-9" Exterior 1 Entry Pivot Door with Side LitesED02 13' - 0" 8'-0" Exterior 2 Aluminum Insulated Glazed Sliding FoldingDoorED03 6' - 0" 8'-0" Exterior 1 Aluminum Narrow Style Insulated GlazedSwing Double DoorED04 6' - 0" 6'-8" Exterior 1 Aluminum Narrow Style Interior GlazedSwing Double DoorED05 2' - 103/4"7'-10 1/2" Exterior 4 Aluminum Narrow Style Insulated GlazedSwing Single DoorED06 3' - 0" 8'-0" Exterior 3 Aluminum Framed Flush Exterior Metal DoorED07 3' - 0" 7'-4" Exterior 1EGD01 8' - 0" 8'-6" Exterior 1 Aluminum Glazed Garage DoorEGD02 16' - 0" 8'-6" Exterior 1 Aluminum Glazed Garage DoorID01 6' - 0" 8'-0" Interior 1 Aluminum Narrow Style Interior GlazedSwing Double DoorID02 3' - 0" 8'-0" Interior 10 Solidcore Flush Wood DoorID03 2' - 6" 8'-0" Interior 10 Solidcore Flush Wood DoorID04 3' - 0" 6'-8" Interior 1 Solidcore Flush Wood DoorID05 3' - 0" 8'-0" Interior 3 Cased OpeningID06 3' - 6" 8'-0" Interior 1 Cased OpeningID07 4' - 0" 8'-0" Interior 1 Cased OpeningID08 5' - 0" 8'-0" Interior 1 Cased OpeningID09 5' - 0" 3'-8 1/2" Interior 1 Cased OpeningID10 6' - 0" 8'-0" Interior 2 Glass Sliding Double DoorID11 4' - 6" 8'-0" Interior 2 Glass Sliding Double DoorID12 4' - 0" 8'-0" Interior 1 Glass Sliding Double DoorID13 2' - 6" 8'-0" Interior 4 Sliding Pocket DoorID14 2' - 4" 8'-0" Interior 1 Glass SlidingPocket DoorID19 4' - 0" 8'-0" Interior 1 Cased OpeningID22 6' - 10" 6'-0" Interior 1ID24 6' - 10" 6'-0" Interior 1Grand total: 57Planning Backcheck Submittal 05: Jan. 08, 2020 Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"16'0"X17'8"Master Bedroom13'0"X17'7"Lower Entry CourtyardRoof's Highest Point716'-0"<E> GRADE25' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level<E>GRADE4A1081232.242.52.69'-0"X17'8"Play Loft4A1093A110-Hallway-HallwayCUT4'-0"CUT3'-3 1/2"<E> GRADE<E>GRADECUT5'-11"CUT4'-0"22'-0"2'-0"5'-0"From lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"<E>GRADE<E> GRADE<E> GRADE<E> GRADE<E>GRADE25' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level2A108Y1Y2Y6Y4Y3Y522'0"X16'0"Living Room16'0"X13'0"Upper Foyer12'0"X12'0"Office18'0"X15'5"Lower Family Room9'8"X13'7"Studio16'0"X16'6"Media Room2A1094A110-East Upper Deck15'6X16'4"Upper West DeckCUT6'-0"CUT4'-0"FILL2'-9"FILL3'-0"3'-8"CUT4'-9"FILL1'-0"694.0022'-0"6'-0"5'-0"From lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"1A108Roof's Highest Point716'-0"<E>GRADE25' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level<E> GRADE<E> GRADE<E>GRADEDCABEGG9D9A1F6H22'1"X31'11"Garage21'0"X15'0"Kitchen11'10"X15'10 1/2"Bedroom10'0"X5'0"Breakfast Nook1A10915'-0"3A1091A110-HallwayF4'-0"CUT3'-8"CUT6'-0"22'-0"From lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"3A108<E> GRADE25' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level<E> GRADE<E> GRADE15'9"X15'3"Bedroom-Hallway13'0"X17'7"Lower Entry Courtyard15'0"X20'0"Upper Family RoomX3X12A110X4X2CUT4'-0"CUT6'-0"CUT4'-0"22'-0"CUT4'-0"From lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:29:44 PMA108Building Sections1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 950321/8" = 1'-0"1Section 11/8" = 1'-0"3Section 31/8" = 1'-0"4Section 41/8" = 1'-0"2Section 2Planning Backcheck Submittal 05: Jan. 08, 2020 Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"4A1081232.242.52.625' Ht. line parallel to<E> Grade Level<E> GRADE25' Ht. line parallel to<E> Grade Level<E>GRADE<E> GRADE4A10912'0"X12'0"Office16'0"X13'0"Upper Foyer3A11018'-4"18'0"X15'5"Lower Family Room-Hallway-East Upper DeckCUT4'-0"6'-0"3'-5"22'-0"From lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"3A108X3X125' Ht. line parallel to<E> Grade Level<E>GRADE<E> GRADE3'-5"12'0"X10'0"Wine Cellar18"X15'0"Dining16'0"X16'6"Media Room22'0"X16'0"Living Room2A110X4X23'-11"FILL2'-9"FILL2'-6"CUT5'-6"25' Ht. line parallel to<E> Grade Level<E> GRADE694.00693.5022'-0"From lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"4A1081232.242.52.64A109CUT6'-0"8'9.5"X6'0"Mech/Pool Equip. Rm.22'1"X31'11"Garage3A11025' Ht. line parallel to<E> Grade LevelCUT3'-0"25' Ht. line parallel to<E> Grade Level<E> GRADE<E> GRADE22'-0"<E> GRADEFrom lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"1A108Roof's Highest Point716'-0"DCABEGG9D9A1F6H1A1093A1096'-11 1/2"11'0"X17'8"Attic/Storage16'0"X9'9 1/2"Master Bath9'-0"X17'8"Play Loft16'0"X17'8"Master Bedroom18'0"X15'5"Lower Family Room12'0"X12'0"Bedroom12'0"X12'0"Office15'0"X20'0"Upper Family Room15'9"X15'3"Bedroom6'0"X9'3"Bath22'1"X31'11"Garage1A110FCUT4'-0 1/2"CUT3'-5"CUT5'-7 3/4"25' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level<E> GRADE<E> GRADE<E> GRADE22'-8"CUT3'-10"From lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:30:09 PMA109Building Sections1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 950321/8" = 1'-0"1Section 51/8" = 1'-0"2Section 61/8" = 1'-0"3Section 71/8" = 1'-0"4Section 8Planning Backcheck Submittal 05: Jan. 08, 2020 Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"4A1081232.242.52.64A1093A110<E> GRADE<E>GRADE<E> GRADE25' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level18'0"X15'5"Lower Family Room12'0"X12'0"Bedroom-East Upper Deck-Hallway13'8"X8'4"Lower Foyer-HallwayCUT4'-0"CUT6'-0"CUT6'-0"22'-0"CUT4'-0"From lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"2A108Y1Y2Y6Y4Y3Y52A1094A11012'0"X10'0"Wine Cellar4'8"X6'0"Closet11'10"X15'10 1/2"Bedroom15'9"X15'3"Bedroom15'0"X20'0"Upper Family Room21'0"X15'0"Kitchen18"X15'0"Dining-East Upper Deck3'-5"FILL3'-0"FILL2'-7"CUT4'-0"CUT3'-0"25' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level<E>GRADE<E>GRADE<E> GRADECUT5'-1"CUT3'-5"22'-9 1/2"From lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"1A108Roof's Highest Point716'-0"DCABEGG9D9A1F6H1A1093A1091A11021'0"X15'0"Kitchen11'10"X15'10 1/2"Bedroom5'10"X6'6"Bath-Hallway9'8"X13'7"Studio-Hallway16'0"X13'0"Upper Foyer13'8"X8'4"Lower Foyer13'0"X17'7"Lower Entry Courtyard12'0"X8'7"Laundry22'1"X31'11"GarageF25' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level<E>GRADE<E> GRADE<E> GRADECUT6'-0"CUT6'-0"4'-0"22'-0"From lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"Lower Floor Level688'-0"Upper Floor Level699'-0"Ceiling Level709'-0"Roof's Highest Point716'-0"3A108X3X12A110X411'10"X15'10 1/2"Bedroom-Hallway13'4"X5'11"Wet Bar9'6"X7'9"Storage16'0"X13'0"Upper Foyer21'0"X15'0"Kitchen10'0"X5'0"Breakfast NookX225' Ht. line parallel to<E> Grade Level25' Ht. line parallel to<E> Grade Level<E> GRADE<E>GRADECUT6'-0"22'-0"<E> GRADEFrom lowest point of building perimeter to the highest28'-0"35' ABV. LowestBuilding Element717'-0"Exisiting AdjacentGrade694'-0"PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:30:39 PMA110Building Sections1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 950321/8" = 1'-0"1Section 91/8" = 1'-0"2Section 101/8" = 1'-0"3Section 111/8" = 1'-0"4Section 12Planning Backcheck Submittal 05: Jan. 08, 2020 PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:30:41 PMA115Perspective Views-011062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 95032AERIAL VIEW FROM NORTH EASTVIEW FROM WESTVIEW FROM RIGHT SIDE YARDVIEW TOWARDS FRONT ENTRYVIEW FROM NORTHPlanning Backcheck Submittal 05: Jan. 08, 2020 PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:30:43 PMA116Perspective Views 021062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 95032VIEW FROM EASTVIEW FROM SOUTH WESTVIEW FROM NORTH WESTVIEW FROM SOUTH EASTVIEW FROM DRIVEWAY9"Planning Backcheck Submittal 05: Jan. 08, 2020 PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:30:46 PMA117Axonometric Views1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 95032AXONOMETRIC VIEW FROM NORTH EASTAXONOMETRIC VIEW FROM NORTH WESTAXONOMETRIC VIEW FROM SOUTH EASTAXONOMETRIC VIEW FROM SOUTH WESTPlanning Backcheck Submittal 05: Jan. 08, 2020 A4A1A1A1A2A1A1A3A3A3A1A3A3A3A3A3A3A5A5A2A2A4A1A4A4?A2A3A2A1A4A3A3A5A1A2A1A4A3A3A3A3A3A2A3A2A5A4A2A7A3A1A3A1A3A1A4A4A2A3A6A7A7A8A8A1A2A3A3A3A3A3A3A2A1A3A5A3A2A2A1A1A7PROJECT NO:DRAWN BY:CHECKED BY:OWNER:SHEETOFSHEET TITLECOPYRIGHT: SRUSTI ARCHITECTS 201912341234ABC408-507-8138 info@srustiarchitects.comCALIFORNIAS T A TEOFDESNECILTCETIHCRA -RSNAVAGAHBANNADAPI 31-2021R EN.01NO.C-30730ARCHITECT:HARI SRIPADANNA AIA LEED APSRUSTI ARCHITECTS18524 MONTPERE WAYSARATOGA CA 95070PHONE:(408) 507 8138Planning Submittal 01: Oct19 2018Planning Backcheck Submittal 02: June12 2019Planning Backcheck Submittal 03: Sep16 2019Planning Backcheck Submittal 04: Oct 25 2019HOA Backcheck Submittal 04: Nov 01 2019Planning Backcheck Submittal 04: Nov 15 201911/14/2019 2:31:25 PMA118Elevations withExterior MaterialsIdentified1062018Olgaard ResidenceAuthorCheckerChristian & Helen Olgaard15365 Santella Court,Los Gatos, CA 950321/8" = 1'-0"1East Elevation with Exterior Materials Identified1/8" = 1'-0"2North Elevation with Exterior Materials Identified1/8" = 1'-0"3South Elevation with Exterior Materials Identified1/8" = 1'-0"4West Elevation with Exterior Materials IdentifiedEast Elevation of MaterialsA1 Iron Corten Sintered Stone Cladding Panel 759 SFA2 Phedra Sintered Stone Cladding Panel 303 SFA3 Glass964 SFA4 Painted steel139 SFA5 Concrete471 SFNorth Elevation of MaterialsA1 Iron Corten Sintered Stone Cladding Panel 332 SFA2 Phedra Sintered Stone Cladding Panel 358 SFA3 Glass630 SFA4 Painted Metal86 SFA5 Concrete176 SFA7 Class A Single Ply Membrane Roofing 49 SFSouth Elevation of MaterialsA1 Iron Corten Sintered Stone Cladding Panel 364 SFA2 Phedra Sintered Stone Cladding Panel 248 SFA3 Glass224 SFA4 Painted steel79 SFA5 Concrete78 SFA6 Solar Panel232 SFA7 Class A Single Ply Membrane Roofing 50 SFA8 Obscure Tempered Glass138 SFWest Elevation of MaterialsA1 Iron Corten Sintered Stone Cladding Panel 699 SFA2 Phedra Sintered Stone Cladding Panel 319 SFA3 Glass396 SFA4 Painted steel135 SFA5 Concrete302 SFA7 Class A Single Ply Membrane Roofing 85 SFLRV tableKeyNameMaterialTotal SF of Material % of total SF LRV SF% x LRVA1 Iron Corten Sintered StoneCladding Panel2154 SF28.28 12.1 342.18A2 Phedra Sintered StoneCladding Panel1228 SF16.12 17 274.04A3 Glass2214 SF2911 319A4 Painted steel439 SF5.712.64 72.04A5 Concrete1027 SF13.48 13.7 184.67A6 Solar Panel232 SF310 30A7 Class A Single PlyMembrane Roofing184 SF2.41 18.1 43.62A8 Obscure Tempered Glass 138 SF1.81 20 36.2Grand total: 87616 SF1301.75Phedra Sintered Stone Cladding PanelType: Stone Cladding PanelColor: Light GrayLRV: 17Source: NeolithIron Corten Sintered Stone Cladding PanelType: Stone Cladding PanelColor: Iron corten LRV: 12.1Source: NeolithClass A Single Ply Membrane RoofingType: N/AColor: GrayLRV: 18.1Source: IB Roof systemsGlass Type: Cardinal LoE 366 dual pane Color: ClearLRV: 11Source: Cardinal Glass IndustriesPainted SteelType: N/AColor: City shadowLRV: 12.64Source: Benjamin MooreConcreteType: Board formed concreteColor: Dark gray LRV: 13.7Source: PolyflorSolar Panel Type: Solar Photovoltaic systemColor: N/ALRV: 10Source: SunPowerCumulative Building LRV : 13.01Planning Backcheck Submittal 05: Jan. 08, 2020 REV.: DEC. 2015 VICINITY MAP PLAN FOR THE IMPROVEMENT OFLANDS OF OLGAARDPARKS AND PUBLIC WORKS DEPARTMENTTOWN OF LOS GATOSTOWN NOTES, PROJECT DATA, LEGEND & ABBREVIATIONSARCHITECTURE AND SITE APPLICATION NO. S-18-052REVISIONSBYDATEPROJECT NO.:SCALE:ENGR:CHECK:DRAWN:DESIGN:DATE: OCTOBER 22, 2019AMXXAMTMAS SHOWN18080SHEET INDEX C1 TOWN NOTES, PROJECT DATA LEGEND & ABBREVIATIONS C2 BLUEPRINT FOR A CLEAN BAY SHEET C3 EXISTING TOPOGRAPHY PLAN C4 SITE PLAN C5 DRIVEWAY PLAN & PROFILE C6 GRADING & DRAINAGE PLAN C7 SECTION AND DETAILS C8 EROSION CONTROL PLAN PLAN FOR THE IMPROVEMENT OF TOWN OF LOS GATOS GRADING & DRAINAGE PLANS ARCHITECTURE AND SITE APPLICATION NO. S-18-052 TOTAL SITE AREA: ____________ SF TOTAL SITE AREA DISTURBED: ____________ SF (INCLUDING CLEARING, GRADING OR EXCAVATING) EXISTING AREA (SF) PROPOSED AREA (SF) REPLACED NEW TOTAL AREA POST-PROJECT (SF) IMPERVIOUS AREA TOTAL NEW & REPLACED IMPERVIOUS AREA PERVIOUS AREA TABLE OF PROPOSED PERVIOUS AND IMPERVIOUS AREAS AB AGGREGATE BASE AC ASPHALT CONCRETE AD AREA DRAIN ARV AIR RELEASE VALVE BC BACK OF CURB BFP BACKFLOW PREVENTER BW BOTTOM OF WALL CATV CABLE TELEVISION CB CATCH BASIN CFS CUBIC FEET PER SECOND C/L CENTERLINE CMP CORRUGATED METAL PIPE CO CLEANOUT CY CUBIC YARD DCVA DOUBLE CHECK VALVE ASSEMBLY DI DROP INLET DIA DIAMETER DIP DUCTILE IRON PIPE DWY DRIVEWAY (E) EAST EG EXISTING GRADE ELEC ELECTRICAL EP EDGE OF PATH EVAE EMERGENCY VEHICLE ACCESS EASEMENT EX EXISTING FC FACE OF CURB FDC FIRE DEPARTMENT CONNECTION FF FINISHED FLOOR ELEVATION FG FINISHED GRADE FH FIRE HYDRANT FL FLOW LINE FM FORCED MAIN FS FIRE SERVICE FT FEET ABBREVIATIONS 8SHEET OF C1CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.G GAS GA GAUGE GB GRADE BREAK GM GAS METER GS GAS SERVICE HDPE HIGH-DENSITY POLYETHYLENE HP HIGH POINT IEE INGRESS/EGRESS EASEMENT IN INCH INV INVERT ELEVATION LAT LATERAL LG LIP OF GUTTER LP LOW POINT MAX MAXIMUM MH MANHOLE MIN MINIMUM MPH MILES PER HOUR (N) NORTH N.T.S. NOT TO SCALE O.C. ON CENTER O.D. OUTSIDE DIAMETER PAD PAD ELEVATION PCC PORTLAND CEMENT CONCRETE PERF PERFORATED PG&E PACIFIC GAS & ELECTRIC COMPANY PIEE PRIVATE INGRESS/EGRESS EASEMENT PL PROPERTY LINE PR PROPOSED PSDE PRIVATE STORM DRAIN EASEMENT PSE PUBLIC SERVICE EASEMENT PSSE PRIVATE SANITARY SEWER EASEMENT PUE PUBLIC UTILITY EASEMENT PVC POLYVINYL CHLORIDE R RADIUS RCP REINFORCED CONCRETE PIPE RIM RIM ELEVATION R/W RIGHT-OF-WAY (S) SOUTH S SLOPE SCC SANTA CLARA COUNTY SCCFD SANTA CLARA COUNTY FIRE DEPARTMENT SD STORM DRAIN SDCO STORM DRAIN CLEANOUT SDE STORM DRAIN EASEMENT SDMH STORM DRAIN MANHOLE SDR STANDARD DIMENSION RATIO SF SQUARE FEET SJWC SAN JOSE WATER COMPANY SS SANITARY SEWER SSCO SANITARY SEWER CLEANOUT SSE SANITARY SEWER EASEMENT SSMH SANITARY SEWER MANHOLE STD STANDARD S/W SIDEWALK TC TOP OF CURB TELE TELEPHONE TLG TOWN OF LOS GATOS TW TOP OF WALL TYP TYPICAL VCP VITRIFIED CLAY PIPE (W) WEST W WATER WM WATER METER WS WATER SERVICE WV WATER VALVE WVSD WEST VALLEY SANITATION DISTRICT XING CROSSING 15365 SANTELLA COURT - APN 527-09-018CIVIL ENGINEERSLAND SURVEYORSCONSTRUCTION MANAGERSHANNA-B UNTTIEST. 19107651 EIGLEBERRY STREET GILROY 95020 CALIFORNIAOFFICE (408) 842-2173 FAX (408) 842-3662EMAIL: ENGINEERING @ HANNABRUNETTI.COMHB JOB NO. 18080 GENERAL NOTES 1. PROPERTY ADDRESS: 15365 SANTELLA COURT 2. PROPERTY OWNER: CHRISTIAN & HELEN OLGAARD 3. ASSESSORS PARCEL NUMBER: 527-09-018 4. EXISTING USE: VACANT 5. EXISTING ZONING: HR-2 1 2: PD 6. PROPOSED USE: SINGLE FAMILY RESIDENTIAL 7. PROPOSED ZONING: HR-2 1 2: PD 8. SITE AREA: 87,475 SQ. FT. (GROSS); DRIVEWAY: 6,797 SQ. FT.; 80,678 SQ. FT. (NET) 9. APPLICANT/DEVELOPER: CHRISTIAN & HELEN OLGAARD 10. CONSULTANTS: 11. WATER SUPPLY: SAN JOSE WATER COMPANY 12. SANITARY SEWER DISPOSAL: WEST VALLEY SANITATION DISTRICT 13. GAS AND ELECTRIC: PACIFIC GAS & ELECTRIC 14. TELEPHONE: FRONTIER COMMUNICATIONS 15. CABLE: XFINITY 16. STORM DRAIN: TOWN OF LOS GATOS 17. FIRE PROTECTION: SANTA CLARA COUNTY FIRE DEPARTMENT 18. DATUM: 19. BASIS OF BEARINGS: BEARINGS AND DISTANCES ON THESE PLANS ARE BASED ON THE "CERTIFICATE OF LOT LINE ADJUSTMENT" DOCUMENT NO. 22956909; DATED MAY 19, 2015. SANTA CLARA COUNTY RECORDER. 20. BENCHMARK INFORMATION: TOPOGRAPHIC SURVEY PROVIDED BY OWNER AND PERFORMED BY OTHERS. PROJECT BENCHMARK SET IN CULDESAC OF SANTELLA COURT A NAIL AND SHINER AT ELEVATION OF 721.01 FEET. TOWN OF LOS GATOS STANDARD GRADING NOTES 1. ALL WORK SHALL CONFORM TO CHAPTER 12 OF THE CODE OF THE TOWN OF LOS GATOS, THE ADOPTED CALIFORNIA BUILDING CODE AND THE LATEST EDITION OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION EXCEPT AS SPECIFIED OTHERWISE ON THESE PLANS AND DETAILS. 2. NO WORK MAY BE STARTED ON-SITE WITHOUT AN APPROVED GRADING PLAN AND A GRADING PERMIT ISSUED BY THE TOWN OF LOS GATOS, PARKS AND PUBLIC WORKS DEPARTMENT LOCATED AT 41 MILES AVENUE, LOS GATOS, CA 95030. 3.A PRE-JOB MEETING SHALL BE HELD WITH THE TOWN ENGINEERING INSPECTOR FROM THE PARKS AND PUBLIC WORKS DEPARTMENT PRIOR TO ANY WORK BEING DONE. THE CONTRACTOR SHALL CALL THE INSPECTIONS LINE AT (4080 399-5771 AT LEAST FORTY-EIGHT (48) HOURS PRIOR TO ANY GRADING OR ONSITE WORK. THIS MEETING SHOULD INCLUDE: a. A DISCUSSION OF THE PROJECT CONDITIONS OF APPROVAL, WORKING HOURS, SITE MAINTENANCE AND OTHER CONSTRUCTION MATTERS; b. ACKNOWLEDGEMENT IN WRITING THAT CONTRACTOR AND APPLICANT HAVE READ AND UNDERSTAND THE PROJECT CONDITIONS OF APPROVAL, AND WILL MAKE CERTAIN THAT ALL PROJECT SUB-CONTRACTORS HAVE READ AND UNDERSTAND THEM PRIOR TO COMMENCING WORK AND THAT A COPY OF THE PROJECT CONDITIONS OF APPROVAL WILL BE POSTED ON SITE AT ALL TIMES DURING CONSTRUCTION. 4. APPROVAL OF PLANS DOES NOT RELEASE THE DEVELOPER OF THE RESPONSIBILITY FOR THE CORRECTION OF MISTAKES, ERRORS, OR OMISSIONS CONTAINED THEREIN. IF, DURING THE COURSE OF CONSTRUCTION OF THE IMPROVEMENTS, PUBLIC INTEREST AND SAFETY REQUIRES A MODIFICATION OR DEPARTURE FROM THE TOWN SPECIFICATIONS OR THESE IMPROVEMENT PLANS, THE TOWN ENGINEER SHALL HAVE FULL AUTHORITY TO REQUIRE SUCH MODIFICATION OR DEPARTURE AND TO SPECIFY THE MANNER IN WHICH THE SAME IS TO BE MADE. 5. APPROVAL OF THIS PLAN APPLIES ONLY TO THE GRADING, EXCAVATION, PLACEMENT, AND COMPACTION OF NATURAL EARTH MATERIALS. THIS APPROVAL DOES NOT CONFER ANY RIGHTS OF ENTRY TO EITHER PUBLIC PROPERTY OR THE PRIVATE PROPERTY OF OTHERS AND DOES NOT CONSTITUTE APPROVAL OF ANY OTHER IMPROVEMENTS. 6. EXCAVATED MATERIAL SHALL BE PLACED IN THE FILL AREAS DESIGNATED OR SHALL BE HAULED AWAY FROM THE SITE TO BE DISPOSED OF AT APPROVED LOCATION(S). 7. IT SHALL BE THE RESPONSIBILITY OF THE PERMITTEE OR CONTRACTOR TO IDENTIFY, LOCATE AND PROTECT ALL UNDERGROUND FACILITIES. PERMITTEE OR CONTRACTOR SHALL NOTIFY USA (UNDERGROUND SERVICE ALERT) AT 1-800-227-2600 A MINIMUM OF FORTY-EIGHT (48) HOURS BUT NOT MORE THAN FOURTEEN (14) DAYS PRIOR TO COMMENCING ALL WORK. 8. ALL GRADING SHALL BE PERFORMED IN SUCH A MANNER AS TO COMPLY WITH THE STANDARDS ESTABLISHED BY THE AIR QUALITY MANAGEMENT DISTRICT FOR AIRBORNE PARTICULATES. 9. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL LAWS, CODES, RULES AND REGULATIONS GOVERNING THE WORK IDENTIFIED ON THESE PLANS. THESE SHALL INCLUDE, WITHOUT LIMITATION, SAFETY AND HEALTH RULES AND REGULATIONS ESTABLISHED BY OR PURSUANT TO THE OCCUPATIONAL SAFETY AND HEALTH ACT OR ANY OTHER APPLICABLE PUBLIC AUTHORITY. 10. THE GENERAL CONTRACTOR SHALL PROVIDE QUALIFIED SUPERVISION ON THE JOB SITE AT ALL TIMES DURING CONSTRUCTION. 11. HORIZONTAL AND VERTICAL CONTROLS SHALL BE SET AND CERTIFIED BY A LICENSED SURVEYOR OR REGISTERED CIVIL ENGINEER QUALIFIED TO PRACTICE LAND SURVEYING, FOR THE FOLLOWING ITEMS: a. RETAINING WALL: TOP OF WALL ELEVATIONS AND LOCATIONS (ALL WALLS TO BE PERMITTED SEPARATELY AND APPLIED FOR AT THE TOWN OF LOS GATOS BUILDING DIVISION). b. TOE AND TOP OF CUT AND FILL SLOPES. 12. PRIOR TO ISSUANCE OF ANY PERMIT, THE APPLICANT'S SOILS ENGINEER SHALL REVIEW THE FINAL GRADING AND DRAINAGE PLANS TO ENSURE THAT DESIGNS FOR FOUNDATIONS, RETAINING WALLS, SITE GRADING, AND SITE DRAINAGE ARE IN ACCORDANCE WITH THEIR RECOMMENDATIONS AND THE PEER REVIEW COMMENTS. THE APPLICANT'S SOILS ENGINEER'S APPROVAL SHALL THEN BE CONVEYED TO THE TOWN EITHER BY LETTER OR BY SIGNING THE PLANS. SOILS ENGINEER ___________________________________________________ REFERENCE REPORT NO. __________________, DATED ____________, 20 ______ LETTER NO. __________, DATED ____________, 20 ___, SHALL BE THOROUGHLY COMPLIED WITH. BOTH THE MENTIONED REPORT AND ALL UPDATES/ADDENDUMS/ LETTERS ARE HEREBY APPENDED AND MADE A PART OF THIS GRADING PLAN. 13. DURING CONSTRUCTION, ALL EXCAVATIONS AND GRADING SHALL BE INSPECTED BY THE APPLICANT'S SOILS ENGINEER. THE ENGINEER SHALL BE NOTIFIED AT LEAST FORTY-EIGHT (48) HOURS BEFORE BEGINNING ANY GRADING. THE ENGINEER SHALL BE ON-SITE TO VERIFY THAT THE ACTUAL CONDITIONS ARE AS ANTICIPATED IN THE DESIGN-LEVEL GEOTECHNICAL REPORT AND/OR PROVIDE APPROPRIATE CHANGES TO THE REPORT RECOMMENDATIONS, AS NECESSARY. ALL UNOBSERVED AND/OR UNAPPROVED GRADING SHALL BE REMOVED AND REPLACED UNDER SOILS ENGINEER OBSERVANCE (THE TOWN INSPECTOR SHALL BE MADE AWARE OF ANY REQUIRED CHANGES PRIOR TO WORK BEING PERFORMED). 14. THE RESULTS OF THE CONSTRUCTION OBSERVATION AND TESTING SHOULD BE DOCUMENTED IN AN “AS-BUILT” LETTER/REPORT PREPARED BY THE APPLICANTS' SOILS ENGINEER AND SUBMITTED FOR THE TOWN'S REVIEW AND ACCEPTANCE BEFORE FINAL RELEASE OF ANY OCCUPANCY PERMIT IS GRANTED. 15. ALL PRIVATE AND PUBLIC STREETS ACCESSING PROJECT SITE SHALL BE KEPT OPEN AND IN A SAFE, DRIVABLE CONDITION THROUGHOUT CONSTRUCTION. IF TEMPORARY CLOSURE IS NEEDED, THEN FORMAL WRITTEN NOTICE TO THE ADJACENT NEIGHBORS AND THE TOWN OF LOS GATOS PARKS AND PUBLIC WORKS DEPARTMENT SHALL BE PROVIDED AT LEAST ONE (1) WEEK IN ADVANCE OF CLOSURE AND NO CLOSURE SHALL BE GRANTED WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE TOWN. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC OR PRIVATE RIGHT-OF-WAY. 16. THE CONTRACTOR SHALL INSTALL AND MAINTAIN FENCES, BARRIERS, LIGHTS AND SIGNS THAT ARE NECESSARY TO GIVE ADEQUATE WARNING AND/PROTECTION TO THE PUBLIC AT ALL TIMES. 17. OWNER/APPLICANT: CHRISTIAN & HELEN OLGAARD PHONE: 408 505-7715 18. GENERAL CONTRACTOR: ________________________ PHONE: ______________ 19. GRADING CONTRACTOR: ________________________ PHONE: ______________ 20.CUT: ±2,348 CY EXPORT: ±2,154 CY FILL: ±194 CY IMPORT: 0 CY 21. WATER SHALL BE AVAILABLE ON THE SITE AT ALL TIMES DURING GRADING OPERATIONS TO PROPERLY MAINTAIN DUST CONTROL. 22. THIS PLAN DOES NOT APPROVE THE REMOVAL OF TREES. APPROPRIATE TREE REMOVAL PERMITS AND METHODS OF TREE PRESERVATION SHALL BE REQUIRED. TREE REMOVAL PERMITS ARE REQUIRED PRIOR TO THE APPROVAL OF ALL PLANS. 23. A TOWN ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK WITHIN THE PUBLIC RIGHT-OF-WAY. A STATE ENCROACHMENT PERMIT IS REQUIRED FOR ANY WORK WITHIN STATE RIGHT-OF-WAY (IF APPLICABLE). THE PERMITTEE AND/OR CONTRACTOR SHALL BE RESPONSIBLE COORDINATING INSPECTION PERFORMED BY OTHER GOVERNMENTAL AGENCIES. 24. NO CROSS-LOT DRAINAGE WILL BE PERMITTED WITHOUT SATISFACTORY STORMWATER ACCEPTANCE DEED/FACILITIES. ALL DRAINAGE SHALL BE DIRECTED TO THE STREET OR OTHER ACCEPTABLE DRAINAGE FACILITY VIA A NON-EROSIVE METHOD AS APPROVED BY THE TOWN ENGINEER. 25. IT IS THE RESPONSIBILITY OF CONTRACTOR AND/OR OWNER TO MAKE SURE THAT ALL DIRT TRACKED INTO THE PUBLIC RIGHT-OF-WAY IS CLEANED UP ON A DAILY BASIS. MUD, SILT, CONCRETE AND OTHER CONSTRUCTION DEBRIS SHALL NOT BE WASHED INTO THE TOWN'S STORM DRAINS. 26. GOOD HOUSEKEEPING PRACTICES SHALL BE OBSERVED AT ALL TIMES DURING THE COURSE OF CONSTRUCTION. SUPERINTENDENCE OF CONSTRUCTION SHALL BE DILIGENTLY PERFORMED BY A PERSON OR PERSONS AUTHORIZED TO DO SO AT ALL TIMES DURING WORKING HOURS. THE STORING OF GOODS AND/OR MATERIALS ON THE SIDEWALK AND/OR THE STREET WILL NOT BE ALLOWED UNLESS A SPECIAL PERMIT IS ISSUED BY THE ENGINEERING DIVISION. THE ADJACENT PUBLIC RIGHT-OF-WAY SHALL BE KEPT CLEAR OF ALL JOB RELATED DIRT AND DEBRIS AT THE END OF THE DAY. FAILURE TO MAINTAIN THE PUBLIC RIGHT-OF-WAY ACCORDING TO THIS CONDITION MAY RESULT IN PENALTIES AND/OR THE TOWN PERFORMING THE REQUIRED MAINTENANCE AT THE DEVELOPER'S EXPENSE. 27. GRADING SHALL BE UNDERTAKEN IN ACCORDANCE WITH CONDITIONS AND REQUIREMENTS OF THE PROJECT STORM WATER POLLUTION CONTROL PLAN AND/OR STORM WATER POLLUTION PREVENTION PLAN (SWPPP), THE TOWN OF LOS GATOS STORM WATER QUALITY MANAGEMENT PROGRAM, NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) AND ANY OTHER PERMITS/REQUIREMENTS ISSUED BY THE STATE OF CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD. PLANS (INCLUDING ALL UPDATES) SHALL BE ON-SITE AT ALL TIMES. NO DIRECT STORMWATER DISCHARGES FROM THE DEVELOPMENT WILL BE ALLOWED ONTO TOWN STREETS OR INTO THE PUBLIC STORM DRAIN SYSTEM WITHOUT TREATMENT BY AN APPROVED STORM WATER POLLUTION PREVENTION DEVICE OR OTHER APPROVED METHODS. MAINTENANCE OF PRIVATE STORMWATER POLLUTION PREVENTION DEVICES SHALL BE THE SOLE RESPONSIBILITY OF THE OWNER. DISCHARGES OR CONNECTION WITHOUT TREATMENT BY AN APPROVED AND ADEQUATELY OPERATING STORMWATER POLLUTION PREVENTION DEVICE OR OTHER APPROVED METHOD SHALL BE CONSIDERED A VIOLATION OF THE ABOVE REFERENCED PERMIT AND THE TOWN OF LOS GATOS STORMWATER ORDINANCE. TOWN OF LOS GATOS NPDES NOTES 1. SEDIMENT FROM AREAS DISTURBED BY CONSTRUCTION SHALL BE RETAINED ON SITE USING STRUCTURAL CONTROLS AS REQUIRED BY THE STATEWIDE GENERAL CONSTRUCTION STORMWATER PERMIT. 2. STOCKPILES OF SOIL SHALL BE PROPERLY CONTAINED TO MINIMIZE SEDIMENT TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES OR ADJACENT PROPERTIES VIA RUNOFF, VEHICLE TRACKING, OR WIND AS REQUIRED BY THE STATEWIDE GENERAL CONSTRUCTION STORMWATER PERMIT. 3. APPROPRIATE BEST MANAGEMENT PRACTICES (BMPS) FOR CONSTRUCTION-RELATED MATERIALS, WASTES, SPILL OR RESIDES SHALL BE IMPLEMENTED TO MINIMIZE TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES, OR ADJOINING PROPERTY BY WIND OR RUNOFF AS REQUIRED BY THE STATEWIDE GENERAL CONSTRUCTION STORMWATER PERMIT. 4. RUNOFF FROM EQUIPMENT AND VEHICLE WASHING SHALL BE CONTAINED AT CONSTRUCTION SITES AND MUST NOT BE DISCHARGED TO RECEIVING WATERS OR TO THE LOCAL STORM DRAIN SYSTEM. 5. ALL CONSTRUCTION CONTRACTOR AND SUBCONTRACTOR PERSONNEL ARE TO BE MADE AWARE OF THE REQUIRED BEST MANAGEMENT PRACTICES (BMPS) AND GOOD HOUSEKEEPING MEASURES FOR THE PROJECT SITE AND ANY ASSOCIATED CONSTRUCTION STAGING AREAS. 6. AT THE END OF EACH DAY OF CONSTRUCTION ACTIVITY, ALL CONSTRUCTION DEBRIS AND WASTE MATERIALS SHALL BE COLLECTED AND PROPERLY DISPOSED IN TRASH OR RECYCLE BINS. 7. CONSTRUCTION SITES SHALL BE MAINTAINED IN SUCH A CONDITION THAT A STORM DOES NOT CARRY WASTE OR POLLUTANTS OFF OF THE SITE. DISCHARGES OF MATERIAL OTHER THAN STORMWATER (NON-STORMWATER DISCHARGES) ARE PROHIBITED EXCEPT AS AUTHORIZED BY AN INDIVIDUAL NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT OR THE STATEWIDE GENERAL CONSTRUCTION STORMWATER PERMIT. POTENTIAL POLLUTANTS INCLUDE BUT ARE NOT LIMITED TO: SOLID OR LIQUID CHEMICAL SPILLS; WASTES FROM PAINTS, STAINS, SEALANTS, SOLVENTS, DETERGENTS, GLUES, LIME, PESTICIDES, HERBICIDES, FERTILIZERS, WOOD PRESERVATIVES AND ASBESTOS FIBERS, PAINT FLAKES OR STUCCO FRAGMENTS; FUELS, OILS, LUBRICANTS, AND HYDRAULIC, RADIATOR OR BATTERY FLUIDS; CONCRETE AND RELATED CUTTING OR CURING RESIDUES; FLOATABLE WASTES; WASTES FROM ENGINE/EQUIPMENT STEAM CLEANING OR CHEMICAL DEGREASING; WASTES FROM STREET CLEANING; AND SUPERCHLORINATED POTABLE WATER FROM LINE FLUSHING AND TESTING. DURING CONSTRUCTION, DISPOSAL OF SUCH MATERIALS SHOULD OCCUR IN A SPECIFIED AND CONTROLLED TEMPORARY AREA ON-SITE PHYSICALLY SEPARATED FROM POTENTIAL STORMWATER RUNOFF, WITH ULTIMATE DISPOSAL IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REQUIREMENTS. 8. DISCHARGING CONTAMINATED GROUNDWATER PRODUCED BY DEWATERING GROUNDWATER THAT HAS INFILTRATED INTO THE CONSTRUCTION SITE IS PROHIBITED. DISCHARGING OF CONTAMINATED SOILS VIA SURFACE EROSION IS ALSO PROHIBITED. DISCHARGING NON-CONTAMINATED GROUNDWATER PRODUCED BY DEWATERING ACTIVITIES REQUIRES A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT FROM THE RESPECTIVE STATE REGIONAL WATER QUALITY CONTROL BOARD. HOUSE FOOTPRINT CUT (CY)MAX CUT HEIGHT (SF) POOL DRIVEWAY / ACCESS LANDSCAPE / OUTDOOR TOTAL FILL (CY)MAX FILL DEPTH (SF)EXPORT (CY) ATTACHED GARAGE ACCESSORY BUILDING CELLAR AREA DESCRIPTION TABLE OF PROPOSED EARTHWORK QUANTITIES ±771 ±189 ±472 ±663 0 0 ±121 ±73 ±2,348 ±194 8.0 11.8 2.6 4 0 0 2.5 3 ±771 ±189 ±351 ±590 ±2,154 N/A ±253 N/A N/A 0 N/A 7.9 0 ±253 REV.: SEPT. 20168SHEET OF C2PARKS AND PUBLIC WORKS DEPARTMENTTOWN OF LOS GATOS REVISIONS BY DATE PROJECT NO.: SCALE: ENGR: CHECK: DRAWN: DESIGN: DATE: OCTOBER 22, 2019 AM XX AM TM NONE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 18080 GRADING & DRAINAGE PLANS LANDS OF OLGAARD BLUEPRINT FOR A CLEAN BAY ARCHITECTURE AND SITE APPLICATION NO. S-18-052 15365 SANTELLA COURT - APN 527-09-018CIVIL ENGINEERS LAND SURVEYORS CONSTRUCTION MANAGERS HANNA-B UN TTI EST. 1910 7651 EIGLEBERRY STREET GILROY 95020 CALIFORNIA OFFICE (408) 842-2173 FAX (408) 842-3662 EMAIL: ENGINEERING @ HANNABRUNETTI.COMHB JOB NO. 18080 LOT 8LOT 9LOT 1010'P.S.D.E.W W W W W WWWW60'DRAINAGE EASEMENTDOC# 19705898REV.: SEPT. 20168SHEET OF C3PARKS AND PUBLIC WORKS DEPARTMENTTOWN OF LOS GATOS REVISIONS BY DATE PROJECT NO.: SCALE: ENGR: CHECK: DRAWN: DESIGN: DATE: OCTOBER 22, 2019 AM XX AM TM 1"=30' CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 18080 GRADING & DRAINAGE PLANS LANDS OF OLGAARD EXISTING TOPOGRAPHY ARCHITECTURE AND SITE APPLICATION NO. S-18-052 15365 SANTELLA COURT - APN 527-09-018CIVIL ENGINEERS LAND SURVEYORS CONSTRUCTION MANAGERS HANNA-B UN TTI EST. 1910 7651 EIGLEBERRY STREET GILROY 95020 CALIFORNIA OFFICE (408) 842-2173 FAX (408) 842-3662 EMAIL: ENGINEERING @ HANNABRUNETTI.COMHB JOB NO. 18080 LOT 8LOT 9LOT 1010'P.S.D.E.W W W W W WWWW60'DRAINAGE EASEMENTDOC# 19705898REV.: SEPT. 20168SHEET OF C4PARKS AND PUBLIC WORKS DEPARTMENTTOWN OF LOS GATOS REVISIONS BY DATE PROJECT NO.: SCALE: ENGR: CHECK: DRAWN: DESIGN: DATE: OCTOBER 22, 2019 AM XX AM TM 1"=30' CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 18080 GRADING & DRAINAGE PLANS LANDS OF OLGAARD GRADING & DRAINAGE PLAN ARCHITECTURE AND SITE APPLICATION NO. S-18-052 15365 SANTELLA COURT - APN 527-09-018CIVIL ENGINEERS LAND SURVEYORS CONSTRUCTION MANAGERS HANNA-B UN TTI EST. 1910 7651 EIGLEBERRY STREET GILROY 95020 CALIFORNIA OFFICE (408) 842-2173 FAX (408) 842-3662 EMAIL: ENGINEERING @ HANNABRUNETTI.COMHB JOB NO. 18080 LOT 910'P.S.D.E.WWWWWREV.: SEPT. 20168SHEET OF C5PARKS AND PUBLIC WORKS DEPARTMENTTOWN OF LOS GATOS REVISIONS BY DATE PROJECT NO.: SCALE: ENGR: CHECK: DRAWN: DESIGN: DATE: OCTOBER 22, 2019 AM XX AM TM 1"=10' CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 18080 GRADING & DRAINAGE PLANS LANDS OF OLGAARD DRIVEWAY PLAN & PROFILE ARCHITECTURE AND SITE APPLICATION NO. S-18-052 15365 SANTELLA COURT - APN 527-09-018CIVIL ENGINEERS LAND SURVEYORS CONSTRUCTION MANAGERS HANNA-B UN TTI EST. 1910 7651 EIGLEBERRY STREET GILROY 95020 CALIFORNIA OFFICE (408) 842-2173 FAX (408) 842-3662 EMAIL: ENGINEERING @ HANNABRUNETTI.COMHB JOB NO. 18080 OT 810'P.S.D.E.REV.: SEPT. 20168SHEET OF C6PARKS AND PUBLIC WORKS DEPARTMENTTOWN OF LOS GATOS REVISIONS BY DATE PROJECT NO.: SCALE: ENGR: CHECK: DRAWN: DESIGN: DATE: OCTOBER 22, 2019 AM XX AM TM 1"=10' CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 18080 GRADING & DRAINAGE PLANS LANDS OF OLGAARD GRADING & DRAINAGE PLAN ARCHITECTURE AND SITE APPLICATION NO. S-18-052 15365 SANTELLA COURT - APN 527-09-018CIVIL ENGINEERS LAND SURVEYORS CONSTRUCTION MANAGERS HANNA-B UN TTI EST. 1910 7651 EIGLEBERRY STREET GILROY 95020 CALIFORNIA OFFICE (408) 842-2173 FAX (408) 842-3662 EMAIL: ENGINEERING @ HANNABRUNETTI.COMHB JOB NO. 18080 5 REV.: SEPT. 20168SHEET OF C7PARKS AND PUBLIC WORKS DEPARTMENTTOWN OF LOS GATOS REVISIONS BY DATE PROJECT NO.: SCALE: ENGR: CHECK: DRAWN: DESIGN: DATE: OCTOBER 22, 2019 AM XX AM TM 1"=10' CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 18080 GRADING & DRAINAGE PLANS LANDS OF OLGAARD SECTION AND DETAILS ARCHITECTURE AND SITE APPLICATION NO. S-18-052 15365 SANTELLA COURT - APN 527-09-018CIVIL ENGINEERS LAND SURVEYORS CONSTRUCTION MANAGERS HANNA-B UN TTI EST. 1910 7651 EIGLEBERRY STREET GILROY 95020 CALIFORNIA OFFICE (408) 842-2173 FAX (408) 842-3662 EMAIL: ENGINEERING @ HANNABRUNETTI.COMHB JOB NO. 18080 LOT 8LOT 9LOT 1010'P.S.D.E.WWWWWWREV.: SEPT. 20168SHEET OF C8PARKS AND PUBLIC WORKS DEPARTMENTTOWN OF LOS GATOS REVISIONS BY DATE PROJECT NO.: SCALE: ENGR: CHECK: DRAWN: DESIGN: DATE: OCTOBER 22, 2019 AM XX AM TM 1"=20' CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 18080 GRADING & DRAINAGE PLANS LANDS OF OLGAARD EROSION CONTROL PLAN ARCHITECTURE AND SITE APPLICATION NO. S-18-052 15365 SANTELLA COURT - APN 527-09-018CIVIL ENGINEERS LAND SURVEYORS CONSTRUCTION MANAGERS HANNA-B UN TTI EST. 1910 7651 EIGLEBERRY STREET GILROY 95020 CALIFORNIA OFFICE (408) 842-2173 FAX (408) 842-3662 EMAIL: ENGINEERING @ HANNABRUNETTI.COMHB JOB NO. 18080