My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ord 1620 - Amending Chapter 12 of the Town Code Relating to the 1982 Uniform Fire Code Requrements for Adequate Water Supply
LFTOWN
>
Clerk
>
Ordinances
>
1600-1699
>
Ord 1620 - Amending Chapter 12 of the Town Code Relating to the 1982 Uniform Fire Code Requrements for Adequate Water Supply
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2016 10:50:43 AM
Creation date
11/14/2011 11:37:42 AM
Metadata
Fields
Template:
Clerks
Docs Ref Code
ORD
Item Ref
1620
Doc Date
6/4/1984
Retention #
COM
Notes - Clerk
Amending Chapter 12 of the Town Code Relating to the 1982 Uniform Fire Code Requrements for Adequate Water Supply
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ORDINANCE NO. 1620 <br />ORDINANCE AMENDING CHAPTER 12 OF THE TOWN CODE <br />RELATING TO THE 1982 UNIFORM -FIRE CODE REQUIRE- <br />MENTS FOR ADEQUATE WATER SUPPLY <br />The Town Council of the Town of Los Gatos hereby ORDAINS: <br />SECTION 1. <br />Section 12.03.045 of the Town Code is hereby amended as follows: <br />Sec. 12.03.045. Adequate water supply. <br />Section 10.301(f) is added to the Uniform Fire Code, as follows: <br />Compliance with the publication, "Guide for Determination of Required Fire Flow," <br />as published by the Insurance Services Office, shall be deemed adequate, except <br />for the following: <br />(1) Where water supplies available for fire protection do not meet <br />the above requirements, buildings equipped throughout with an approved automatic <br />sprinkler system need not mandatorily comply with the provisions of this section. <br />(2) Buildings in excess of two (2) stories in height or that require <br />a fire flow - in excess of 2,000 gallons per minute shall be equipped throughout <br />with an approved automatic sprinkler system. For the purpose of this subsection, <br />dwellings with exterior walls protected in accordance with the provisions of the <br />Building Code need not comply.. For the purposes of calculating fire flow, area <br />and occupancy separation walls may not be used to reduce the building size. <br />CFCTTnN 2 <br />This ordinance takes effect-30 days after the date it is adopted. <br />Within 15 days after this ordinance is adopted the Town Clerk shall cause it to <br />be published once in a newspaper of general circulation published and circulated <br />in the Town. <br />This ordinance <br />was introduced at a <br />regular <br />meeting of the <br />Town Council of the Town <br />of Los Gatos on <br />May 21st, 1984 <br />, and adopted <br />by the following vote as <br />an ordinance of the <br />Town of Los Gatos <br />at a regular <br />
The URL can be used to link to this page
Your browser does not support the video tag.