Attachment 5 Exhibit 7 PlansHULTS
RESTAURANT
HULTS RESTAURANT 65 LOS G 95
SARATOGA ROAD
LOS GATOS, CA A 95030
PROPOSED RESTAURANT PATIO wA 4pm
165 LOS GATOS- SARATOGA ROAD, CONSUce TS,INC
C1 N 1TANTSI INC.
LOS GATOS, CA 95030 ..- ...ml...
Man,xR
PLANNING REVIEW
NfW
NOT FOR CONSTRUCTION
3/31/2015
m <m axNExrs JOIN
-i9 RSYf TOP (IM1 MWEMS
=.t Oa %MVxXG PENp I/31/IS
t.o I.wMIM eL„E� tt /zon.
wt M /Vu
eaon.
A. LORENZO RIOS, JR.
JASON ROTHWDN
o.Ae...a Hueo aEDA
mCawWQ LORENZO A RIOS
A' ULTS
RESTAURANT PATIO
4 -51a -m
T' ::.a.. wmcnmztxx ____ ___
RE
VICINITY MAP, SITE MAP,
MAR 3 2M%NGINDEXD
TOWN O LOS GATOS
PLANNI G DIVISION
;EXHIBIT 7
4/8/15 PC Staff Rpt
NTS
" ~ G -0.0
VICINITY MAP ASSESSOR PARCEL MAP SITE PLAN
P Salw Y1 Cnmptli &[u ofln 6bf 'sw rr.va a oar. -
O rt ®s.a.. . ao� ea •�a II11 (� j1 (�
WAIN n� � w( � RrviPM Or a a zAwrt �
M�ll'�IE vu¢ Y
W1 M'� irtee[PSgsCa(x6[a &tn9 a—N SANTA Oi11Z -�� .._AVE
f °
a aacnmaW wu9.xem Pe.nn.nw e"°'Gh°Re•se ,. � w 5 � s n9 �: o �!
L
i
rs t
VW9 ✓a pa k 1 S �( p HULi'S RESTAURANT �
tmann J1', y1
1
C R eM1iC temWratY w L /. 1
i aM 8� I l t
?L Sr ,:20a• s , - ..xa<a „am ,mn, ,.m.:•e, _- " I /. ..- ,-a4 ".
Fmkex RlinS eaM, °...
P`M.GAp Welk
� Fmueml 1'I 4a �°
20A 1 /
bl Rc N VQ
Um Gaw P S 0 `.
O J
� OFFICE OF COUNTY ASSESSOR
165 LOS GATOS— SARATOGA ROAD,
DRAWING INDEX
PROJECT DATA
PROJECT DESCRIPTION
NUN6ER
GENERAL
LOT SIZE: 15.909 50. Fi.
EXISTING STRUCTURES
RESTAURANT. 4,192
TOTAL: b.t92
EXISTING COVERAGE: 3.]9f.
OCCUPANCY TYPE A -2
CONSTRUCTION ttPE: II -B
FIRE SPRINKLER STATUS: NONE
NUMBER OF Bi0RlE5: I STORY BUILDING
{ PROJECT CONSISTS OF THE PLANNING OF A PROPOSED PATIO FOR
I,;LLS RESTAURANT IN THE TOWN OF LOS GATOS.
G -0.0
VICINITY MAP, SRE MPP, PROJECT OAT4 & DRAWING INpEX.
G -1 0
E %STING SITE PUN AND NOTES
G -30
EXIT, PARKING LOT SITE PLAIN AND NOTES
G -2.t
PROPOSED PATIO PUN WITH ASSESSORS PARCEL MAP
G -S.O
PROPOSED (N) PPTIO PUJJ AND NOTES
G -4.0
PROPOSED (rv) PATIO WALL ELEVATION
CODES AND REGULATIONS
DEFERRED SUBMITTALS
2013 CALIFORNIA BUILDING CODE
2013 CALIFORNIA PIKE CODE
2013 CALIFORNIA CALIFORNW MECHANICAL CODE
2013 CALIFORNIA PLUMBING CODE
2013 CALIFORNIA ELECTRIC CODE
2013 CALIFORNIA TITLE 24 ENERGY REGULATIONS
2013 CALIFORNIA TITLE 24 ACCESSIBILITY STANDARDS
DEFERRED SUBMITTALS THAT ARE NOT SUBMITTED AT THE TIME OF THE
APPLICATION MUST HAVE THE PRIOR APPROVAL OF lHE BUILDING
OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE
CHARGE SHALL LIST THE DEFERRED $UBMIIIaLS ON THE CONSTRUCTION
DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR
DEFERRED SUBMITTAL ITEMS SHALL BE REVIEWED BY THE REGISTERED
DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL FORWARD
THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT
THEY HAVE BEEN REVIEWED AND ARE IN GENERAL CONFORMANCE WITH
THE DESIGN OF THE BUILDING:
1- NONE
LOS GATOS CA 95030
SANTA CLARA COUNTY CALIFORNIA
1KI1 SCALL NOrvE
HULTrS RESTAURANT
SCALE: rvOrvE
SITE PLAN
SCALE: NONE
DRAWING INDEX
PROJECT DATA
PROJECT DESCRIPTION
NUN6ER
GENERAL
LOT SIZE: 15.909 50. Fi.
EXISTING STRUCTURES
RESTAURANT. 4,192
TOTAL: b.t92
EXISTING COVERAGE: 3.]9f.
OCCUPANCY TYPE A -2
CONSTRUCTION ttPE: II -B
FIRE SPRINKLER STATUS: NONE
NUMBER OF Bi0RlE5: I STORY BUILDING
{ PROJECT CONSISTS OF THE PLANNING OF A PROPOSED PATIO FOR
I,;LLS RESTAURANT IN THE TOWN OF LOS GATOS.
G -0.0
VICINITY MAP, SRE MPP, PROJECT OAT4 & DRAWING INpEX.
G -1 0
E %STING SITE PUN AND NOTES
G -30
EXIT, PARKING LOT SITE PLAIN AND NOTES
G -2.t
PROPOSED PATIO PUN WITH ASSESSORS PARCEL MAP
G -S.O
PROPOSED (N) PPTIO PUJJ AND NOTES
G -4.0
PROPOSED (rv) PATIO WALL ELEVATION
CODES AND REGULATIONS
DEFERRED SUBMITTALS
2013 CALIFORNIA BUILDING CODE
2013 CALIFORNIA PIKE CODE
2013 CALIFORNIA CALIFORNW MECHANICAL CODE
2013 CALIFORNIA PLUMBING CODE
2013 CALIFORNIA ELECTRIC CODE
2013 CALIFORNIA TITLE 24 ENERGY REGULATIONS
2013 CALIFORNIA TITLE 24 ACCESSIBILITY STANDARDS
DEFERRED SUBMITTALS THAT ARE NOT SUBMITTED AT THE TIME OF THE
APPLICATION MUST HAVE THE PRIOR APPROVAL OF lHE BUILDING
OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE
CHARGE SHALL LIST THE DEFERRED $UBMIIIaLS ON THE CONSTRUCTION
DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR
DEFERRED SUBMITTAL ITEMS SHALL BE REVIEWED BY THE REGISTERED
DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL FORWARD
THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT
THEY HAVE BEEN REVIEWED AND ARE IN GENERAL CONFORMANCE WITH
THE DESIGN OF THE BUILDING:
1- NONE
UNIVERSITY AVENUE
HULT'S RESTAU ANT EXISTING SITE PLAN AND NOTES
SCALE: 1/8 1 -O
GENERAL NOTES:
OASSFSSnR PAR F V ^e N iMB R:
B3 529 -04 -083
ZONE:
C -2 ZONE CENTRAL BUSINESS DISTRICT COMMERCIAL ZONE.
A LOT WIN C -2 ZONE TENT ABVTS OR 15 ACROSS THE
STREET FROM A RESIDENTIAL ZONE MUST COMPLY WITH
THE FOLLOWING MINIMUM YARD REOUIREMENTS:
FRONT: 15 FEET
SIDE: 20 FEET
REAR: 20 FEET
STREET SIDE: 15 FEET
HULTS
RESTAURANT
165 LOS GATOS-
SARATOGA ROAD
LOS GATOS. CA 95030
twula„s ....r..en..�....1
PLANNING REVIEW
NOT FOR CONSTRUCTION
3/31/2015
HULTS
RESTAURANT PATIO
amts
GENERAL
HULTS RESTAURANT
EXISTING SITE
PLAN AND NOTES
1 /e' -
G -1.0
UNIVERSITY AVENUE �WEW X, rq,
I161 ULT RESTAURANT EXIT, PARKING LOT S1TE PLAN
SCALE: 1 /B? = Y-0"
IX
PARKING- CALCULAT ONS
PER LG MUNICIPAL CODE SEC. 29.10.150(0)(4):
ONE (1) PARKING SPACE FOR EACH THREE (3) SEATS
EXISTING SEATS 105
PROPOSED SEATS: 53
TOTAL SEATS = 158 / 3 = 53
PARKING- PROVDED
EXISTING STANDARD SPACES 11 SPACES
EXISTING ASSIGNED TOWN SPACES 46 SPACES
EXISTING HANDICAP ACCESSIBLE-VAN --------- 01 SPACES
TOTAI = 58 SPACr5
EGRESS ACCESSIBLE CODE COMPLIANCE:
HULTS
1. EXCEPT AS SPECIFICALLY PERMITTED SY THIS SECTION EGRESS DOORS
RESTAURANT
SHALL BE READ RY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF
A KEY OR SPECIAL KNOWLEDGE OR EFFORT.
165 LOS GATOS-
LBC_ma6.1.9 DOOR OPERATIONS.
SARATOGA ROAD
2. FIRE DWRS SHALL HAVE A MINIMUM OPENING FOR ALLOWABLE BY THE
LOS GATOS, CA 95030
APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 LEE.
yid
OTHER THAN REQUIRED FIRE MORS, INTERIOR AND EXTERIOR ODORS SHALL
HAVE A MAXIMUM OPENING FORCE OF 5 LSF.
CBC_118- 404.2.9 DOOR AND CATE OPENING FORCE.
ADVANCE DESIGN
-,- CONSULTANTS, INC
3. DOORWAYS SHALL HAVE A MINIMUM CLEAR OPENING OF 32" WITH THE
DOOR OPEN 90 DEGREES, MEASURED BETWEEN FACE OF DOOR TO THE
OPPOSITE STOP.
CBC_I1D- 404.2.3 CLEAR WIDTH.
4. EXISTING FACILITIES ARE IN FULL COMPLIANCE WITH CURRENT DISABLED
ACCESS REGULATIONS PER CHAPTER 11 CBC 2015.
5. THE HIGHEST OPERABLE PART OF ALL CONTROL. DISPENSER. RECEPTACLES
AND OTHER OPERABLE EQUIPMENT SHALL BE PLACED WITHIN AT LEAST ONE
_
OF THE REACH RANGES SPECIFIED IN SECTIONS 1113-308.2 AND 118 -308.3
CBC_118 -308 REACH RANGES.
6. WHERE A FORWARD REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH
SHALL BE 48 INCHES MAX. AND THE LOW FORWARD REACH SHALL BE 15
INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND.
CBC_118 -308.2 FORWARD REACH.
]. WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL
APPROACH TO AN ELEMENT AND THE SIOE REACH IS UNOBSTRUCTED. THE
HIGH SIDE REACH SHALL BE 48 INCHES MAX. AND THE LOW SIDE REACH
SHALL BE 15 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND,
CBC_II8-308.3 SIDE REACH.
6. WHEN SIGNS DIRECT OR GIVE INFORMATION (EXIT SIGNAGE) THEY SHALL
COMPLY WITH SECTIONS CBC 118-216 SIGNS.
CDC 118 -216.3 DIRECTIONAL AND INFORMATIONAL SIGN.
EXITING NOTES:
I. DOOR HARDWARE:
EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A
KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.
2. EXIT SIGNS:
THE PATH OF TRAVEL TO HE WITHIN EXITS IN A BUILDING SHALL BE
IDENTIFIED BY EXIT SIGNS CONFORMING TO THE REQUIREMENTS OF CDC 1011
PLANNING REVIEW
EXIT SIGNS SHALL BE READILY VISIBLE FROM THE DIRECTION OF APPROACH
& LOCATED AS NECESSARY TO INDICATE THE DIRECTION OF EGRESS TRAVEL
NO POINT SHALL BE MORE THAN 100 FEET FROM THE NEAREST VISIBLE
NOT FOR CONSTRUCTION
3/31 /2015
SIGN. TACTILE EXIT SIGNS SHOULD ALSO BE PROVIDED PER DEC SECTIONS
1011.3
3. MEANS OF EGRESS ILLUMINATION:
AT MY MAE THE BUILDING 15 OCCUPIED, THE MEANS OF EGRESS SHALL BE
ILLUMINATED AT AN INTENSITY OF NO LESS THAN 1 FT- CANDLE AT FLOOR
LEVEL.
4. ILLUMINATION POWER SUPPLY:
POWER SUPPLY FOR MFPNS OF EGRESS ILLUMINATION SHALL NORMALLY BE
PROVIDED BY THE PREMISES ELECTRICAL SUPPLY. IN THE EVENT OF ITS
FAILURE. ILLUMINATION TO BE AUTOMATICALLY PROVIDED FROM AN
EMERGENCY SYSTEM WHERE THE EXITING SYSTEM SERVES AN OCCUPANT
LOAD OF 100 OR MORE.
5. AISLES WITHOUT FIXED SEATS:
L
FI PA ma
1/11 /15
AISLES SERVING AS A PORTION OF AN EXIT ACCESS IN THE MEANS OF
EGRESS SYSTEM SHALL BE IN ACCORDANCE WITH CDC 101a.a.
gq[FGA 111r [GUUEm2
Jpa /IS
EGAI RR .11K MN(v
/P/+5
& ROOM CAPACITY:
ROOM HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL HAVE THE
Ru[ [w Fuwxc u++[x
a /aP /IANY
m1 WXOV
10/e/'x
CAPACITY OF THE ROOM POSTED IN A CONSPICUOUS PLACE.
®L
ffi
7. ACCESSIBLE PATHS OF TRAVEL:
EX
EXISTING EXTERIOR PATHS TRAVEL FROM PARKING MAIN BUILDING
ENTRANCES COMPLY WITH CURRENT ACCESSIBILITY REGULATIONS. ALL
EXISTING AND NEW INTERIOR PUBLIC AREAS INCLUDING OFFICES, CLASS /CONE
ROOMS, BREAK ROOMS AND TOILETS TO COMPLY WITH CURRENT
ACCESSIBILITY REGULATIONS.
FIRE DEPARTMENT NOTES:
L FIRE EXTNGUISHERS'.
ALL PORTIONS OF THE BUILDING SHALL BE WITHIN 75' OF A FIRE
EXTINGUISHER. THE MIN. SIZE OF EXTINGUISHER TO BE 2Ai OBC
2, AUTOMATIC SHUT -OFFS:
EACH SINGLE SYSTEM PROVIDING HEATING OR COOLING AIR IN EXCESS OF
2,000 CUBIC FT /MIN. SHALL BE EQUIPPED WITH AN AUTOMATIC SHUTOFF
ACTIVATED SY SMOKE DETECTORS,
3. ADDRESS:
APPROVED NUMBERS OR ADDRESSES SHALL BE PLACED ON ALL NEW &
EXISTING BUILDINGS IN SUCH A POSITION TO BE VISIBLE & LEGIBLE FROM
THE STREET OR ROAD FRONTING THE PROPERTY.
LOP E N20 RIGS
JASON BOTHWEIN
EGRESS CALCULATIONS:
wWM,AFW[R
Huco a.1
OCCUPANT LOADS
USE FACTOR & INDEX LOAD HULTS
(E) DINING 1070 E / is 136 RESTAURANT
(E) KITCHEN 1,200 SF / 200 6
(E) STORAGE 44] SF / 300 1.5 14- 514 -01
(N) PATIO 10]0 SF / 15 ]t
215
NUMBER OF EXITS REQUIRED: 2
GENERAL
RESTAURANT HAS TWO REQUIRED EXITS, THREE TOTAL EXITS. THE NEW PATIO
HAS TWO EXISTS.
HULTS RESTAURANT
EXIT SEPARATION
EXIT, PARKING LOT
MAXIMUM DIAGONAL bs' -O"
SITE PLAN AND NOTES
EXIT SEPARATION: 40' -0" > 36 " -0"
DOOR WIDTH VERIFICATION
36" EXISTING DOOR WIDTH / 0.15 - 240 MAX. OCCUPANTS
215 OCCUPANTS / 3 EXITS X 0.15 (INCHES PER PERSON) = 10.75" OF
_
1 /B' = 1' -0.
FOOD WIDTH REQUIRED PER EXIT. 36` EXITS PROVIDED COMPLY.
" G -2.0
<_g
UNIVERSIN AVENUE
I� HULT s' - RESTAURANT PROPOSED PATIO PLAN WITH ASSESSORS PARCEL MAP
a 4i / AY
RANT
HULTS
RESTAURANT
165 LOS GATOS-
SARATOGA ROAD
LOS GATOS, CA 95030
PLANNING REVIEW
NOT FOR CONSTRUCTION
3/31/2015
HULTS
RESTAURANT PATIO
GENERAL
HULTS RESTAURANT
PROPOSED PATIO PLAN
WITH
ASSESSORS PARCEL MAP
r -o'
i
ox
pT PM
/ f/ z
(EI n.."
HULTS
GENERAL NOTES: RESTAURANT
Qi PATIO TO BE CONSTRUCTED USING 165 LOS GATOS-
PERVIOUS CONCRETE AND /Oft PATIO SLOPE SARATOGA ROAD
TO ORAN (NORTHEAST) TOW
UJJDSCAOING NO ADDITIONRL ARDS LOS GATOS, CA 95030
X{ COVERAGE PROPOSED FOR NEW R, —
Q2 NEW PATIO ENCLOSURE SHALL CONFORM
TO 'SIGHT TRIANGLE AND TRAFFIC VIEW
AREA STD. PLAN N0, 232 AND THE TOWN
/ OF LOS GATES LATEST EDITION OF
q) ENT / MUNICIPAL CODES /REGULNTIONS. A ADVANCE DESIGN
Oj NEW PING WALL SHALL BE L HIGH ,,CONSULTANTS, INC.
/ MATCHING EXISTING SMALL SLOPE AND A
1 (E) *¢KAM PUIP MINIMUM OF 15' FROM ROADWAY EDGE TO an. nve
1 MEET TOWN OF LOS GATOS CODE: SECTION
rvs ruurnue •u ase s
23,10.060. PATIO WALL NEAR ENTRANCE
jd I SHALL BE 36" MAX HEIGHT SINCE IT IS
1, 'Ar2T - /W PROPOSED TO ENCROACH INTO TRAFFIC
4 II %W, / VIEW AREA.
I _
'41- WRE MILE
I
E:
-D
1 °R� uLFRR ".
TAIa " 1 111 a
° Aii,/J�, / aRO uo F. R2.
�I ip
/ 5 Cv.FD 0 E LL /
3 I ."I PPi O510M1E /
a Es wo Aw PLANNING REVIEW
!� ( (SLOiE or rWi ro .+Tw
cw.c� / NOT FOR CONSTRUCTION
3/31/2015
1
) 1 � / IERWE RF qM1 W".Ex15 J /J� /i5
() PATIO I e 90 RVC fOP <IM1 CO"KMS 3/ ] /i5
I O"CpFTE i5 •1 �/ ` (4 ZTO (M 4L O / PU59Z1 101i %MNNC FENp /Z)/ 5
wm RSLE 9aR HW� ""a n,
IuRIW
1 '
fGP FENEF 19 /En.
L� wM slcuII so "E /
I /
1
s+ia/
LORENZO RIOS
wowrrte JASON ROTHWEIN
/ `'/ MIWIMI¢ NON OJEDA
.F�W.ve LORENZO A I'm
S
HULTS
/ o RESTAURANT PATIO
la -SU -m
GENERAL
/ HULTS RESTAURANT
PROPSED (N) PATIO
PLAN AND NOTES
/6 -
"`T� G -3.0
1i
!1
F 1 {
--
t7
II
HULTS
GENERAL NOTES: RESTAURANT
Qi PATIO TO BE CONSTRUCTED USING 165 LOS GATOS-
PERVIOUS CONCRETE AND /Oft PATIO SLOPE SARATOGA ROAD
TO ORAN (NORTHEAST) TOW
UJJDSCAOING NO ADDITIONRL ARDS LOS GATOS, CA 95030
X{ COVERAGE PROPOSED FOR NEW R, —
Q2 NEW PATIO ENCLOSURE SHALL CONFORM
TO 'SIGHT TRIANGLE AND TRAFFIC VIEW
AREA STD. PLAN N0, 232 AND THE TOWN
/ OF LOS GATES LATEST EDITION OF
q) ENT / MUNICIPAL CODES /REGULNTIONS. A ADVANCE DESIGN
Oj NEW PING WALL SHALL BE L HIGH ,,CONSULTANTS, INC.
/ MATCHING EXISTING SMALL SLOPE AND A
1 (E) *¢KAM PUIP MINIMUM OF 15' FROM ROADWAY EDGE TO an. nve
1 MEET TOWN OF LOS GATOS CODE: SECTION
rvs ruurnue •u ase s
23,10.060. PATIO WALL NEAR ENTRANCE
jd I SHALL BE 36" MAX HEIGHT SINCE IT IS
1, 'Ar2T - /W PROPOSED TO ENCROACH INTO TRAFFIC
4 II %W, / VIEW AREA.
I _
'41- WRE MILE
I
E:
-D
1 °R� uLFRR ".
TAIa " 1 111 a
° Aii,/J�, / aRO uo F. R2.
�I ip
/ 5 Cv.FD 0 E LL /
3 I ."I PPi O510M1E /
a Es wo Aw PLANNING REVIEW
!� ( (SLOiE or rWi ro .+Tw
cw.c� / NOT FOR CONSTRUCTION
3/31/2015
1
) 1 � / IERWE RF qM1 W".Ex15 J /J� /i5
() PATIO I e 90 RVC fOP <IM1 CO"KMS 3/ ] /i5
I O"CpFTE i5 •1 �/ ` (4 ZTO (M 4L O / PU59Z1 101i %MNNC FENp /Z)/ 5
wm RSLE 9aR HW� ""a n,
IuRIW
1 '
fGP FENEF 19 /En.
L� wM slcuII so "E /
I /
1
s+ia/
LORENZO RIOS
wowrrte JASON ROTHWEIN
/ `'/ MIWIMI¢ NON OJEDA
.F�W.ve LORENZO A I'm
S
HULTS
/ o RESTAURANT PATIO
la -SU -m
GENERAL
/ HULTS RESTAURANT
PROPSED (N) PATIO
PLAN AND NOTES
/6 -
"`T� G -3.0
HULTS
RESTAURANT
165 LOS GATOS-
SARATOGA ROAD
LOS GATOS, CA 95030
III
ADVANCE DESIGN
CONSULTANTS, INC.
EIIISTRINII PLANNING REVIEW
NOT FOR CONSTRUCTION
3/31/2015
x[ <m mxrs snVrs
AN
d-111 EN, "I CITY CCxK x,S IPSP5 NVX SHEET NOTES" sN[ NN P—WR x[.,[w „ ,Dial.
(N) EMERGENCY EXIT SHALL BE ALARMED PROVEN � PP!
AND LOCKED FROM THE OUTSIDE TO
PREVENT PUBLIC ENTRY. EMERGENCY EXIT
SHALL BE LABELED 'EMERGENCY EXIT ONLY
ALARM WILL SOUND" ON INSIDE DOOR.
rcnnxExoxem LOflENZO R105
owmlr[Ixs: HlGO 'JEDA
Ino[,aal� I IORENZO A. Ri05
(x) [u[Kixc [ar
HULTS
` -0 RESTAURANT PATIO
IN) "Ll
— — (MA) la -sla Di
[mow.
-
.)__ � GENERAL
HULTS RESTAURANT
L N:.awsor,rvc rurul+ss (p n c +m na[ wA� [°n =ono [xa°scP[. PROPSED (N) PATIO
x°xx,.
M.m WA TO wrcr. (EL 5T�KEE
FIF IN FRONT sac xrMF9 x ANA Axaxo
xcmowwr.
x ES o o� (s°o[ El wA[ ro x. m sm[w «x cPm[)
WALL ELEVATION
HUL S RESTAURANT PROPOSED (N) PATIO WALL ELEVATION
I SCALE:a - I' 0'
1/6" - I' 0'
G -4.0